WorldWideScience

Sample records for kidneys-1 clip model

  1. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat

    OpenAIRE

    Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.; Robertson, Tom P.

    2011-01-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40–60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips ma...

  2. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.

    Science.gov (United States)

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P

    2012-02-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.

  3. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats

    OpenAIRE

    Stephen P. Chelko; Chad W. Schmiedt; Tristan H. Lewis; Tom P. Robertson; Stephen J. Lewis

    2014-01-01

    This study compared the contractile responses elicited by angiotensin II (AII), arginine vasopressin (AVP), and 5-hydroxytryptamine (5-HT) in isolated occipital arteries (OAs) from sham-operated (SHAM) and 2-kidney, 1-clip (2K-1C) hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery) and distal segments (closer to the nodose ganglion) and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, hea...

  4. Right ventricular pressure elevated in one-kidney, one clip Goldblatt hypertensive rats.

    Science.gov (United States)

    Ketabchi, Farzaneh; Bajoovand, Shirin; Adlband, Mojtaba; Naseh, Maryam; Nekooeian, Ali A; Mashghoolozekr, Elaheh

    2017-01-01

    Both renal and respiratory diseases are common with high mortality rate around the world. This study was the first to compare effects of two kidneys, one clip (2K1C) and one-kidney, one clip (1K1C) Goldblatt hypertension on right ventricular pressure during normal condition and mechanical ventilation with hypoxia gas. Male Sprague-Dawley rats were subjected to control, 2K1C, or 1K1C groups. Twenty-eight days after the first surgery, animals were anesthetized, and femoral artery and vein, and right ventricle cannulated. Systemic arterial pressure and right ventricular systolic pressures (RVSP) were recorded during ventilation the animals with normoxic or hypoxic gas. RVSP in the 1K1C group was significantly more than the control and 2K1C groups during baseline conditions and ventilation the animals with hypoxic gas. Administration of antioxidant Trolox increased RVSP in the 1K1C and control groups compared with their baselines. Furthermore, there was no alteration in RVSP during hypoxia in the presence of Trolox. This study indicated that RVSP only increased after 28 days induction of 1K1C but not 2K1C model. In addition, it seems that the response to hypoxic gas and antioxidants in 1K1C is more than 2K1C. These data also suggest that effects of 1K1C may partially be related to reactive oxygen species (ROS) pathways.

  5. CHANGES IN RENAL-FUNCTION INDUCED BY ACE-INHIBITION IN THE CONSCIOUS 2-KIDNEY, ONE-CLIP GOLDBLATT HYPERTENSIVE DOG

    NARCIS (Netherlands)

    JONKER, GJ; VISSCHER, CA; DEZEEUW, D; HUISMAN, RM; PIERS, DA; BEEKHUIS, H; VANDERHEM, GK

    In order to study why the diagnostic sensitivity of I-123-hippurate renography for a renal artery stenosis is improved by angiotensin converting enzyme (ACE-) inhibition we used the model of the conscious chronically instrumented two-kidney, one-clip Goldblatt hypertensive dog. Urine flow (UV),

  6. Antihypertensive therapy induces compartment-specific chemokine expression and a Th1 immune response in the clipped kidney of Goldblatt hypertensive rats

    NARCIS (Netherlands)

    Steinmetz, O. M.; Sadaghiani, S.; Panzer, U.; Krebs, C.; Meyer-Schwesinger, C.; Streichert, T.; Fehr, S.; Hamming, I.; van Goor, H.; Stahl, R. A. K.; Wenzel, U.

    The present study examined the pathogenesis of interstitial inflammation and fibrosis in antihypertensively treated rats with two-kidney, one-clip hypertension. Hypertensive rats were randomized into four groups: no treatment and moderate, intermediate, and intensified lowering of blood pressure

  7. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats.

    Science.gov (United States)

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Robertson, Tom P; Lewis, Stephen J

    2014-01-01

    This study compared the contractile responses elicited by angiotensin II (AII), arginine vasopressin (AVP), and 5-hydroxytryptamine (5-HT) in isolated occipital arteries (OAs) from sham-operated (SHAM) and 2-kidney, 1-clip (2K-1C) hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery) and distal segments (closer to the nodose ganglion) and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, heart rates, and plasma renin concentrations than SHAM rats. The contractile responses to AII were markedly diminished in both proximal and distal segments of OAs from 2K-1C rats as compared to those from SHAM rats. The responses elicited by AVP were substantially greater in distal than in proximal segments of OAs from SHAM rats and that AVP elicited similar responses in OA segments from 2K-1C rats. The responses elicited by 5-HT were similar in proximal and distal segments from SHAM and 2K-1C rats. These results demonstrate that continued exposure to circulating AII and AVP in 2K-1C rats reduces the contractile efficacy of AII but not AVP or 5-HT. The diminished responsiveness to AII may alter the physiological status of OAs in vivo.

  8. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats

    Directory of Open Access Journals (Sweden)

    Stephen P. Chelko

    2014-01-01

    Full Text Available This study compared the contractile responses elicited by angiotensin II (AII, arginine vasopressin (AVP, and 5-hydroxytryptamine (5-HT in isolated occipital arteries (OAs from sham-operated (SHAM and 2-kidney, 1-clip (2K-1C hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery and distal segments (closer to the nodose ganglion and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, heart rates, and plasma renin concentrations than SHAM rats. The contractile responses to AII were markedly diminished in both proximal and distal segments of OAs from 2K-1C rats as compared to those from SHAM rats. The responses elicited by AVP were substantially greater in distal than in proximal segments of OAs from SHAM rats and that AVP elicited similar responses in OA segments from 2K-1C rats. The responses elicited by 5-HT were similar in proximal and distal segments from SHAM and 2K-1C rats. These results demonstrate that continued exposure to circulating AII and AVP in 2K-1C rats reduces the contractile efficacy of AII but not AVP or 5-HT. The diminished responsiveness to AII may alter the physiological status of OAs in vivo.

  9. Training model for cerebral aneurysm clipping

    Directory of Open Access Journals (Sweden)

    Hiroshi Tenjin, M.D., Ph.D.

    2017-12-01

    Full Text Available Clipping of cerebral aneurysms is still an important skill in neurosurgery. We have made a training model for the clipping of cerebral aneurysms. The concepts for the model were 1: training model for beginners, 2: three dimensional manipulation using an operating microscope, 3: the aneurysm model is to be perfused by simulated blood causing premature rupture. The correct relationship between each tissue, and softness of the brain and vessels were characteristics of the model. The skull, brain, arteries, and veins were made using a 3D printer with data from DICOM. The brain and vessels were made from polyvinyl alcohol (PVA. One training course was held and this model was useful for training of cerebral aneurysm surgery for young neurosurgeons.

  10. Flax lignan concentrate attenuate hypertension and abnormal left ventricular contractility via modulation of endogenous biomarkers in two-kidney-one-clip (2K1C hypertensive rats

    Directory of Open Access Journals (Sweden)

    Sameer Hanmantrao Sawant

    Full Text Available ABSTRACT The present investigation was designed to study the effect of flax lignan concentrate obtained from Linum usitatissimum L., Linaceae, in two-kidney, one clip (2K1C hypertension model in Wistar rats. 2K1C Goldblatt model rats were divided randomly into six groups: sham, 2K1C control, captopril (30 mg/kg, flax lignan concentrate (200, 400 and 800 mg/kg. Flax lignan concentrate and captopril were administered daily for eight consecutive weeks. Sham-operated, and 2K1C control rats received the vehicle. Treatment with flax lignan concentrate (400 and 800 mg/kg significantly and dose-dependently restored the hemodynamic parameters systolic blood pressure, diastolic blood pressure, mean arterial blood pressure and left ventricular functions. The flax lignan concentrate significantly restored the elevated hepatic, renal and cardiac marker enzymes in the serum. It also restored the organs weights (kidney and heart, serum electrolyte level and histological abnormalities. Furthermore, flax lignan concentrate significantly elevated the level of biochemical markers that is enzymatic antioxidants superoxide dismutase, glutathione and decreased malondialdehyde in the heart and kidney tissues. Meanwhile, we found that plasma nitric oxide and plasma nitric oxide synthase contents were significantly increased in the flax lignan concentrate-treated group, and plasma endothelin-1 and renal angiotensin-II levels were significantly lower than 2K1C hypertensive group. In conclusion, the antihypertensive and antioxidant effect of flax lignan concentrate were dose-dependent and at the highest dose (i.e. 800 mg/kg similar to those of captopril (30 mg/kg. It is suggested that flax lignan concentrate reduced blood pressure by reduction of renal angiotensin-II level, inhibition of plasma endothelin-1 production, induction of the nitric oxide, nitric oxide synthase and in vivo antioxidant defense system.

  11. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.

    Science.gov (United States)

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-03-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.

  12. Water and exchangeable sodium in Goldblatt two-kidney, two-clip hypertensive rats

    International Nuclear Information System (INIS)

    Mac Cormack, W.P.; Roson, M.I.; Maquieira, M.K.; Mendez, M.A.; Santoro, F.M.; Morera, S.; de la Riva, I.J.

    1986-01-01

    Exchangeable 22 Na (ExNa), total body water (TBW) and the inulin space (InSp) were determined in two-kidney, two-clip (2K-2C) hypertensive and sham operated (normotensive) control rats 6-8 weeks after surgery. TBW (ml/kg lean body weight) was the same in hypertensive and sham rats. In contrast, ExNa (mEq/kglbw) and InSp (ml/kglbw) significantly increased (p less than 0.01) in rats whose hypertension did not exceed 170 mmHg. Consequently, sham, moderate hypertensive (less than 170 mmHg) and severe hypertensive (less than 170 mmHg) animals showed equal TBW but differed in body water distribution in that moderately hypertensive animals displayed a redistribution of water in favor of the extracellular space

  13. Laparoscopic kidney orthotopic transplant: preclinical study in the pig model.

    Science.gov (United States)

    He, B; Musk, G C; Mou, L; Waneck, G L; Delriviere, L

    2013-06-01

    Laparoscopic surgery has rapidly expanded in clinical practice replacing conventional open surgery over the last three decades. Laparoscopic donor nephrectomy has been favored due to its multiple benefits. The aim of this study was to explore the safety and feasibility of kidney transplantation by a laparoscopic technique in a pig model. The study was approved by the university animal ethics committee. Eight female pigs (Sus Scrofra, weighing 45-50 kg) were divided into 2 groups: group I included 4 animals that underwent laparoscopic kidney orthotopic transplantation on the left side. The right kidney was remained functional in situ. The pigs recovered and were observed for 1 week. In the 4 hosts group II pigs underwent a laparoscopic kidney transplantation on the left side. With simultaneous clipping of the right ureter. After recovery, the pigs were observed for 4 weeks. A laparotomy for examination was performed prior to euthanasia. All 4 group I pigs survived for 1 week. The laparotomy showed normal graft perfusion with wall patent renal artery and vein as well as satisfactory urine output upon transection of ureter in 3 hosts. Renal artery stenosis occurred in one pig. In The Immediate kidney graft function was achieved in 3 group II pigs. The fourth died following extubation due to laryngospasm despite a functional graft. The average creatinine levels were 195.5 μmol/L on day 3; 224.5 μmol/L at week 1; 127 μmol/L at week 2; 182.7 umol/L at week 3; and 154.7 umol/L at week 4. Laparoscopic kidney transplantation was feasible and safe in a pig model with immediate graft function. This study will provide further evidence to support application of laparoscopic technique to human kidney transplant. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Angiotensin converting enzyme inhibition induces alterations to hippuran renography despite unchanged ipsilateral renal blood flow in conscious two-kidney, one clip Goldblatt hypertensive dogs

    NARCIS (Netherlands)

    Jonker, G J; de Zeeuw, D; Huisman, R M; van der Hem, G K

    1988-01-01

    We performed experiments in the two-kidney, one clip Goldblatt hypertensive dog to see whether angiotensin converting enzyme (ACE) inhibition could improve the sensitivity of hippurate renography in detecting renal artery stenosis. Ten dogs on a sodium-restricted diet were studied before and after

  15. Acute urinary retention secondary to a urethral calculus in a bladder-drained kidney pancreas transplant patient - a metallic clip nidus.

    Science.gov (United States)

    Smith, J B K; Sairam, K; Olsburgh, J

    2009-01-01

    Urological expertise is usually required for the management of any urological complications of bladder-drained pancreatic allografts whether they are the result of simultaneous pancreas-kidney transplants, pancreas after kidney transplants, or pancreas transplants alone. This study presents a case of urinary retention secondary to prostatic urethra calculus impaction, the nidus of which was found to be metallic staples from the donor duodenal segment of a pancreatic allograft. Knowledge of the pre-transplant benchwork gave a high index of suspicion to the urological sequelae of this case and, in particular, the presence of calculi should suggest a metal clip nidus. We examine the methods of exocrine pancreatic drainage, donor duodenum preparation and case management.

  16. Modeling Timbre Similarity of Short Music Clips.

    Science.gov (United States)

    Siedenburg, Kai; Müllensiefen, Daniel

    2017-01-01

    There is evidence from a number of recent studies that most listeners are able to extract information related to song identity, emotion, or genre from music excerpts with durations in the range of tenths of seconds. Because of these very short durations, timbre as a multifaceted auditory attribute appears as a plausible candidate for the type of features that listeners make use of when processing short music excerpts. However, the importance of timbre in listening tasks that involve short excerpts has not yet been demonstrated empirically. Hence, the goal of this study was to develop a method that allows to explore to what degree similarity judgments of short music clips can be modeled with low-level acoustic features related to timbre. We utilized the similarity data from two large samples of participants: Sample I was obtained via an online survey, used 16 clips of 400 ms length, and contained responses of 137,339 participants. Sample II was collected in a lab environment, used 16 clips of 800 ms length, and contained responses from 648 participants. Our model used two sets of audio features which included commonly used timbre descriptors and the well-known Mel-frequency cepstral coefficients as well as their temporal derivates. In order to predict pairwise similarities, the resulting distances between clips in terms of their audio features were used as predictor variables with partial least-squares regression. We found that a sparse selection of three to seven features from both descriptor sets-mainly encoding the coarse shape of the spectrum as well as spectrotemporal variability-best predicted similarities across the two sets of sounds. Notably, the inclusion of non-acoustic predictors of musical genre and record release date allowed much better generalization performance and explained up to 50% of shared variance ( R 2 ) between observations and model predictions. Overall, the results of this study empirically demonstrate that both acoustic features related

  17. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability

    OpenAIRE

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Hilger Ropers, H; Galjart, Niels; Najmabadi, Hossein

    2015-01-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which ...

  18. [Rapid 3-Dimensional Models of Cerebral Aneurysm for Emergency Surgical Clipping].

    Science.gov (United States)

    Konno, Takehiko; Mashiko, Toshihiro; Oguma, Hirofumi; Kaneko, Naoki; Otani, Keisuke; Watanabe, Eiju

    2016-08-01

    We developed a method for manufacturing solid models of cerebral aneurysms, with a shorter printing time than that involved in conventional methods, using a compact 3D printer with acrylonitrile-butadiene-styrene(ABS)resin. We further investigated the application and utility of this printing system in emergency clipping surgery. A total of 16 patients diagnosed with acute subarachnoid hemorrhage resulting from cerebral aneurysm rupture were enrolled in the present study. Emergency clipping was performed on the day of hospitalization. Digital Imaging and Communication in Medicine(DICOM)data obtained from computed tomography angiography(CTA)scans were edited and converted to stereolithography(STL)file formats, followed by the production of 3D models of the cerebral aneurysm by using the 3D printer. The mean time from hospitalization to the commencement of surgery was 242 min, whereas the mean time required for manufacturing the 3D model was 67 min. The average cost of each 3D model was 194 Japanese Yen. The time required for manufacturing the 3D models shortened to approximately 1 hour with increasing experience of producing 3D models. Favorable impressions for the use of the 3D models in clipping were reported by almost all neurosurgeons included in this study. Although 3D printing is often considered to involve huge costs and long manufacturing time, the method used in the present study requires shorter time and lower costs than conventional methods for manufacturing 3D cerebral aneurysm models, thus making it suitable for use in emergency clipping.

  19. A model-based approach to identify binding sites in CLIP-Seq data.

    Directory of Open Access Journals (Sweden)

    Tao Wang

    Full Text Available Cross-linking immunoprecipitation coupled with high-throughput sequencing (CLIP-Seq has made it possible to identify the targeting sites of RNA-binding proteins in various cell culture systems and tissue types on a genome-wide scale. Here we present a novel model-based approach (MiClip to identify high-confidence protein-RNA binding sites from CLIP-seq datasets. This approach assigns a probability score for each potential binding site to help prioritize subsequent validation experiments. The MiClip algorithm has been tested in both HITS-CLIP and PAR-CLIP datasets. In the HITS-CLIP dataset, the signal/noise ratios of miRNA seed motif enrichment produced by the MiClip approach are between 17% and 301% higher than those by the ad hoc method for the top 10 most enriched miRNAs. In the PAR-CLIP dataset, the MiClip approach can identify ∼50% more validated binding targets than the original ad hoc method and two recently published methods. To facilitate the application of the algorithm, we have released an R package, MiClip (http://cran.r-project.org/web/packages/MiClip/index.html, and a public web-based graphical user interface software (http://galaxy.qbrc.org/tool_runner?tool_id=mi_clip for customized analysis.

  20. Dynamics of cocaine- and amphetamine-regulated transcript containing cell changes in the adrenal glands of two kidney, one clip rats.

    Science.gov (United States)

    Kasacka, Irena; Piotrowska, Zaneta; Janiuk, Izabela; Zbucki, Robert

    2014-10-01

    Taking into consideration the homeostatic disorders resulting from renal hypertension and the essential role of cocaine- and amphetamine-regulated transcript (CART) in maintaining homeostasis by regulating many functions of the body, the question arises as to what extent the renovascular hypertension affects the morphology and dynamics of changes of CART-containing cells in the adrenal glands. The aim of the present study was to examine the distribution, morphology, and dynamics of changes of CART-containing cells in the adrenal glands of "two kidney, one clip" (2K1C) renovascular hypertension model in rats. The studies were carried out on the adrenal glands of rats after 3, 14, 28, 42, and 91 days from the renal artery clipping procedure. To identify neuroendocrine cells, immunohistochemical reaction was performed with the use of a specific antibody against CART. It was revealed that renovascular hypertension causes changes in the endocrine cells containing CART in the adrenal glands of rats. The changes observed in the endocrine cells depend on the time when the rats with experimentally induced hypertension were examined. In the first period of hypertension, the number and immunoreactivity of CART-containing cells were decreased, while from the 28-day test, it significantly increased, as compared to the control rats. CART is relevant to the regulation of homeostasis in the cardiovascular system and seems to be involved in renovascular hypertension. The results of the present work open the possibility of new therapeutic perspectives for the treatment of arterial hypertension, since CART function is involved in their pathophysiology. © 2014 by the Society for Experimental Biology and Medicine.

  1. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    Science.gov (United States)

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and

  2. Influence of percutaneous mitral valve repair using the MitraClip® system on renal function in patients with severe mitral regurgitation.

    Science.gov (United States)

    Rassaf, Tienush; Balzer, Jan; Rammos, Christos; Zeus, Tobias; Hellhammer, Katharina; v Hall, Silke; Wagstaff, Rabea; Kelm, Malte

    2015-04-01

    In patients with mitral regurgitation (MR), changes in cardiac stroke volume, and thus renal preload and afterload may affect kidney function. Percutaneous mitral valve repair (PMVR) with the MitraClip® system can be a therapeutic alternative to surgical valve repair. The influence of MitraClip® therapy on renal function and clinical outcome parameters is unknown. Sixty patients with severe MR underwent PMVR using the MitraClip® system in an open-label observational study. Patients were stratified according to their renal function. All clips have been implanted successfully. Effective reduction of MR by 2-3 grades acutely improved KDOQI class. Lesser MR reduction (MR reduction of 0-1 grades) led to worsening of renal function in patients with pre-existing normal or mild (KDOQI 1-2) compared to severe (KDOQI 3-4) renal dysfunction. Reduction of MR was associated with improvement in Minnesota Living with Heart Failure Questionnaire (MLHFQ), NYHA-stadium, and 6-minute walk test. Successful PMVR was associated with an improvement in renal function. The improvement in renal function was associated with the extent of MR reduction and pre-existing kidney dysfunction. Our data emphasize the relevance of PVMR to stabilize the cardiorenal axis in patients with severe MR. © 2014 Wiley Periodicals, Inc.

  3. MiR-139-3p is related to left ventricular hypertrophy and cardiomyocyte apoptosis in two-kidney one-clip hypertensive rats

    Directory of Open Access Journals (Sweden)

    Yang Xiaomin

    2015-01-01

    Full Text Available MicroRNAs (miRNAs are important post-transcriptional regulators of gene expression in many physiological and pathological processes. Previous studies have reported the role of miR-139-3p in cancer. However, its specific roles and functions in the heart undergoing hypertrophy have yet to be fully elucidated. In the present study, a significant upregulation of miR-139-3p expression was demonstrated in the left ventricular myocardium of two-kidney one-clip (2K1C hypertensive rats using microarray and quantitative real-time PCR (qRT-PCR. Based on computational analysis, we observed that miR-139-3p can control the expression of mitogen-activated protein kinase 1 (MAPK1 as a target gene, which is essential for the induction of cardiac hypertrophy and cardiomyocyte apoptosis. This study provides first information that the highly expressed miR-139-3p might be closely involved in MAPK1-mediated cardiac hypertrophy and cardiomyocyte apoptotic processes in 2K1C rat.

  4. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    Science.gov (United States)

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  5. Concept of the central clip

    DEFF Research Database (Denmark)

    Alegria-Barrero, Eduardo; Chan, Pak Hei; Foin, Nicolas

    2014-01-01

    AIMS: Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. We analyse the concept of the central clip and the predictors for the need of more than one MitraClip(®) in our high.......8±10.7 years (30 males, 13 females; mean logistic EuroSCORE 24.1±11, mean LVEF 47.5±18.5%; mean±SD) were treated. Median follow-up was 385 days (104-630; Q1-Q3). Device implantation success was 93%. All patients were treated following the central clip concept: 52.5% of MR was degenerative in aetiology and 47....... The presence of a restricted posterior mitral valve leaflet (PML) was inversely correlated with the need for more than one clip (p=0.02). A cut-off value of ≥7.5 mm for vena contracta predicted the need for a second clip (sensitivity 83%, specificity 90%, p=0.01). CONCLUSIONS: The central MitraClip(®) concept...

  6. Seismic signals hard clipping overcoming

    Science.gov (United States)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  7. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Directory of Open Access Journals (Sweden)

    David A Bridwell

    Full Text Available Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33% and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%, with accuracies ranging from 52.9% (Silver Linings Playbook to 11.75% (Seinfeld within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  8. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Science.gov (United States)

    Bridwell, David A; Roth, Cullen; Gupta, Cota Navin; Calhoun, Vince D

    2015-01-01

    Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's) emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33%) and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%), with accuracies ranging from 52.9% (Silver Linings Playbook) to 11.75% (Seinfeld) within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz) primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  9. [Intervention effects of Zuoguiwan containing serum on osteoblast through ERK1/2 and Wnt/β-catenin signaling pathway in models with kidney-Yang-deficiency, kidney-Yin-deficiency osteoporosis syndromes].

    Science.gov (United States)

    Zhang, Jian-Hua; Xin, Jing; Fan, Lian-Xia; Yin, Hua

    2017-10-01

    To clarify the effects of Zuoguiwan containing serum on osteoblast proliferation and alkaline phosphatase(ALP) expression and its effects on the expression of β-catenin, ERK1, ERK2 mRNA and protein of osteoblast through ERK1/2, Wnt/β-catenin signaling pathway in models with osteoporosis(OP) kidney-Yang-deficiency, osteoporosis(OP) kidney-Yin-deficiency syndrome. Rat osteoporosis models were established by ovariectomy surgery, and 10 weeks after surgery, hydrocortisone was injected and thyroxine was administered by intragastric administration to establish OP kidney-Yang-deficiency rat model, and OP kidney-Yin-deficiency rat model. Osteoblasts were obtained from 24 h newborn rat skull and were identified by alkaline phosphatase and alizarin red staining. Zuoguiwan containing serum of OP, OP kidney-Yang-deficiency, and OP kidney-Yin-deficiency, as well as the blank serum were used to intervene the osteoblast, and the cells proliferation was detected by MTS. ELISA assay was used to detect ALP expression. RT-PCR assay was used to detect the mRNA expression of ERK1, ERK2, β-catenin and protein expression levels were detected by Western blot. The results showed that Zuoguiwan containing serum in OP kidney-Yin-deficiency model had stronger effect than OP kidney-Yang-deficiency in promoting osteoblast proliferation, ALP expression, osteoblast ERK1/2, Wnt/β-catenin signaling pathway related factors β-catenin, ERK1, ERK2 mRNA and protein expression levels. This was consistent with the TCM theory of "Zuoguiwan nourishes kidney Yin", providing a scientific basis for the clinical and dialectical treatment of osteoporosis. Zuoguiwan could regulate the proliferation and differentiation of bone cells by ERK1/2 and Wnt/β-catenin signaling pathway, which may be one of the mechanisms of Zuoguiwan for the prevention of osteoporosis. Copyright© by the Chinese Pharmaceutical Association.

  10. Derivation and External Validation of Prediction Models for Advanced Chronic Kidney Disease Following Acute Kidney Injury.

    Science.gov (United States)

    James, Matthew T; Pannu, Neesh; Hemmelgarn, Brenda R; Austin, Peter C; Tan, Zhi; McArthur, Eric; Manns, Braden J; Tonelli, Marcello; Wald, Ron; Quinn, Robert R; Ravani, Pietro; Garg, Amit X

    2017-11-14

    Some patients will develop chronic kidney disease after a hospitalization with acute kidney injury; however, no risk-prediction tools have been developed to identify high-risk patients requiring follow-up. To derive and validate predictive models for progression of acute kidney injury to advanced chronic kidney disease. Data from 2 population-based cohorts of patients with a prehospitalization estimated glomerular filtration rate (eGFR) of more than 45 mL/min/1.73 m2 and who had survived hospitalization with acute kidney injury (defined by a serum creatinine increase during hospitalization > 0.3 mg/dL or > 50% of their prehospitalization baseline), were used to derive and validate multivariable prediction models. The risk models were derived from 9973 patients hospitalized in Alberta, Canada (April 2004-March 2014, with follow-up to March 2015). The risk models were externally validated with data from a cohort of 2761 patients hospitalized in Ontario, Canada (June 2004-March 2012, with follow-up to March 2013). Demographic, laboratory, and comorbidity variables measured prior to discharge. Advanced chronic kidney disease was defined by a sustained reduction in eGFR less than 30 mL/min/1.73 m2 for at least 3 months during the year after discharge. All participants were followed up for up to 1 year. The participants (mean [SD] age, 66 [15] years in the derivation and internal validation cohorts and 69 [11] years in the external validation cohort; 40%-43% women per cohort) had a mean (SD) baseline serum creatinine level of 1.0 (0.2) mg/dL and more than 20% had stage 2 or 3 acute kidney injury. Advanced chronic kidney disease developed in 408 (2.7%) of 9973 patients in the derivation cohort and 62 (2.2%) of 2761 patients in the external validation cohort. In the derivation cohort, 6 variables were independently associated with the outcome: older age, female sex, higher baseline serum creatinine value, albuminuria, greater severity of acute kidney injury, and higher

  11. Authoring Data-Driven Videos with DataClips.

    Science.gov (United States)

    Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang

    2017-01-01

    Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.

  12. Effect of advanced chronic kidney disease in clinical and echocardiographic outcomes of patients treated with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Pighi, Michele

    2015-01-01

    BACKGROUND: Data regarding the influence of different levels of renal dysfunction on clinical and echocardiographic results of MitraClip therapy are scarce. We aimed to evaluate the impact of baseline advance renal failure in the outcomes of a cohort of patients treated with MitraClip. METHODS AN...

  13. Expression of Nek1 during kidney development and cyst formation in multiple nephron segments in the Nek1-deficient kat2J mouse model of polycystic kidney disease.

    Science.gov (United States)

    Chen, Yumay; Chiang, Huai-Chin; Litchfield, Patricia; Pena, Michelle; Juang, Charity; Riley, Daniel J

    2014-07-17

    Neks, mammalian orthologs of the fungal protein kinase never-in-mitosis A, have been implicated in the pathogenesis of polycystic kidney disease. Among them, Nek1 is the primary protein inactivated in kat2J mouse models of PKD. We report the expression pattern of Nek1 and characterize the renal cysts that develop in kat2J mice. Nek1 is detectable in all murine tissues but its expression in wild type and kat2J heterozygous kidneys decrease as the kidneys mature, especially in tubular epithelial cells. In the embryonic kidney, Nek1 expression is most prominent in cells that will become podocytes and proximal tubules. Kidney development in kat2J homozygous mice is aberrant early, before the appearance of gross cysts: developing cortical zones are thin, populated by immature glomeruli, and characterized by excessive apoptosis of several cell types. Cysts in kat2J homozygous mice form postnatally in Bowman's space as well as different tubular subtypes. Late in life, kat2J heterozygous mice form renal cysts and the cells lining these cysts lack staining for Nek1. The primary cilia of cells lining cysts in kat2J homozygous mice are morphologically diverse: in some cells they are unusually long and in others there are multiple cilia of varying lengths. Our studies indicate that Nek1 deficiency leads to disordered kidney maturation, and cysts throughout the nephron.

  14. Kidney compartment model

    International Nuclear Information System (INIS)

    Gullberg, G.T.

    1976-09-01

    A multiparameter kidney compartment model which quantitates the amount of iodohippurate concentration as a function of time in the blood, tissue, kidneys and bladder is developed from a system of differential equations which represent first order kinetics. The kinetic data are obtained using a gamma camera and an HP5407 computer system which allows one to delineate areas of interest for the blood and tissue, kidneys, and bladder thus separating the data into four data sets. The estimated tubular transit times have a high ratio of the signal to the variance whereas the estimates of the amount of iodohippurate in the blood, tissue and kidneys have a low ratio of the signal to the variance. Application of this model to patient data requires better statistics than available with conventional 131 I-hippurate doses; thus a true test of the efficacy awaits availability of 123 I-hippurate

  15. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  16. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  17. Fuzzy expert systems using CLIPS

    Science.gov (United States)

    Le, Thach C.

    1994-01-01

    This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.

  18. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, Elmar M.; Thomas, John; Paulson, Erik K. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Dale, Brian M. [Siemens Medical Solutions, Cary, NC (United States)

    2006-10-15

    To evaluate whether clips from prior cholecystectomy impair image quality during magnetic resonance cholangiography (MRC) at 3 Tesla (T) compared with 1.5 T, surgical clips were embedded in a gel phantom and positioned at predefined distances from a fluid-filled tube designed to simulate the bile duct. The maximum clip distance was noted where susceptibility artifacts obscured the fluid-filled tube at 1.5 T and 3 T. Susceptibility artifact size was calculated for each sequence within each magnet class. In vivo analysis included 42 patients postcholecystectomy who underwent MRC at either 1.5 T or 3 T. In vitro, mean area of susceptibility artifacts was 104 mm{sup 2} on 3-T and 75 mm{sup 2} on 1.5-T MR imaging (MRI). While surgical clips within a 2-mm range impaired visualization of the fluid-filled tube on 1.5-T MRI, this range increased to 4 mm on 3-T MRI. In vivo, MRC image quality was impaired by susceptibility artifacts in three of 21 cases at 3 T and in two of 21 cases at 1.5 T. Overall, biliary pseudo-obstructions due to susceptibility artifacts from cholecystectomy surgical clips were not substantially more common on 3-T MRC in clinical practice, and patients with a history of prior cholecystectomy should not be excluded from a 3-T MRC. (orig.)

  19. Selective Activation of AMPK β1-Containing Isoforms Improves Kidney Function in a Rat Model of Diabetic Nephropathy.

    Science.gov (United States)

    Salatto, Christopher T; Miller, Russell A; Cameron, Kimberly O; Cokorinos, Emily; Reyes, Allan; Ward, Jessica; Calabrese, Matthew F; Kurumbail, Ravi G; Rajamohan, Francis; Kalgutkar, Amit S; Tess, David A; Shavnya, Andre; Genung, Nathan E; Edmonds, David J; Jatkar, Aditi; Maciejewski, Benjamin S; Amaro, Marina; Gandhok, Harmeet; Monetti, Mara; Cialdea, Katherine; Bollinger, Eliza; Kreeger, John M; Coskran, Timothy M; Opsahl, Alan C; Boucher, Germaine G; Birnbaum, Morris J; DaSilva-Jardine, Paul; Rolph, Tim

    2017-05-01

    Diabetic nephropathy remains an area of high unmet medical need, with current therapies that slow down, but do not prevent, the progression of disease. A reduced phosphorylation state of adenosine monophosphate-activated protein kinase (AMPK) has been correlated with diminished kidney function in both humans and animal models of renal disease. Here, we describe the identification of novel, potent, small molecule activators of AMPK that selectively activate AMPK heterotrimers containing the β 1 subunit. After confirming that human and rodent kidney predominately express AMPK β 1, we explore the effects of pharmacological activation of AMPK in the ZSF1 rat model of diabetic nephropathy. Chronic administration of these direct activators elevates the phosphorylation of AMPK in the kidney, without impacting blood glucose levels, and reduces the progression of proteinuria to a greater degree than the current standard of care, angiotensin-converting enzyme inhibitor ramipril. Further analyses of urine biomarkers and kidney tissue gene expression reveal AMPK activation leads to the modulation of multiple pathways implicated in kidney injury, including cellular hypertrophy, fibrosis, and oxidative stress. These results support the need for further investigation into the potential beneficial effects of AMPK activation in kidney disease. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.

  20. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.

    Science.gov (United States)

    Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed

    2016-01-01

    A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 th postoperative day and the second group on the 60 th postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 th postoperative day, but there was no statistical difference. Even on the 60 th postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.

  1. Clip reconstruction of a large right MCA bifurcation aneurysm. Case report

    Directory of Open Access Journals (Sweden)

    Giovani A.

    2014-06-01

    Full Text Available We report a case of complex large middle cerebral artery (MCA bifurcation aneurysm that ruptured during dissection from the very adherent MCA branches but was successfully clipped and the MCA bifurcation reconstructed using 4 Yasargill clips. Through a right pterional craniotomy the sylvian fissure was largely opened as to allow enough workspace for clipping the aneurysm and placing a temporary clip on M1. The pacient recovered very well after surgery and was discharged after 1 week with no neurological deficit. Complex MCA bifurcation aneurysms can be safely reconstructed using regular clips, without the need of using fenestrated clips or complex by-pass procedures.

  2. Cux1 promotes cell proliferation and polycystic kidney disease progression in an ADPKD mouse model.

    Science.gov (United States)

    Porath, Binu; Livingston, Safia; Andres, Erica L; Petrie, Alexandra M; Wright, Joshua C; Woo, Anna E; Carlton, Carol G; Baybutt, Richard; Vanden Heuvel, Gregory B

    2017-10-01

    Autosomal dominant polycystic kidney disease (ADPKD) is one of the most common monogenic hereditary disorders in humans characterized by fluid-filled cysts, primarily in the kidneys. Cux1, a cell cycle regulatory gene highly expressed during kidney development, is elevated in the cyst-lining cells of Pkd1 mutant mice, and in human ADPKD cells. However, forced expression of Cux1 is insufficient to induce cystic disease in transgenic mice or to induce rapid cyst formation after cilia disruption in the kidneys of adult mice. Here we report a double mutant mouse model that has a conditional deletion of the Pkd1 gene in the renal collecting ducts together with a targeted mutation in the Cux1 gene (Pkd1 CD ;Cux1 tm2Ejn ). While kidneys isolated from newborn Pkd1 CD mice exhibit cortical and medullary cysts, kidneys isolated from newborn Pkd1 CD ;Cux1 tm2Ejn-/- mice did not show any cysts. Because Cux1 tm2Ejn-/- are perinatal lethal, we evaluated Pkd1 CD mice that were heterozygote for the Cux1 mutation. Similar to the newborn Pkd1 CD ;Cux1 tm2Ejn-/- mice, newborn Pkd1 CD ;Cux1 tm2Ejn+/- mice did not show any cysts. Comparison of Pkd1 CD and Pkd1 CD ;Cux1 tm2Ejn+/- mice at later stages of development showed a reduction in the severity of PKD in the Pkd1 CD ;Cux1 tm2Ejn+/- mice. Moreover, we observed an increase in expression of the cyclin kinase inhibitor p27, a target of Cux1 repression, in the rescued collecting ducts. Taken together, our results suggest that Cux1 expression in PKD is not directly involved in cystogenesis but promotes cell proliferation required for expansion of existing cysts, primarily by repression of p27. Copyright © 2017 the American Physiological Society.

  3. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  4. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  5. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  6. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  7. Preserving Sharp Edges with Volume Clipping

    NARCIS (Netherlands)

    Termeer, M.A.; Oliván Bescós, J.; Telea, A.C.

    2006-01-01

    Volume clipping is a useful aid for exploring volumetric datasets. To maximize the effectiveness of this technique, the clipping geometry should be flexibly specified and the resulting images should not contain artifacts due to the clipping techniques. We present an improvement to an existing

  8. Remission of migraine after clipping of saccular intracranial aneurysms

    DEFF Research Database (Denmark)

    Lebedeva, E R; Busygina, A V; Kolotvinov, V S

    2015-01-01

    interview. The remission rates of migraine and tension-type headache (TTH) in these patients were compared to 92 patients from a headache center. Diagnoses were made according to the ICHD-2. RESULTS: During 1 year preceding rupture 51 patients with SIA had migraine. During the year after clipping......BACKGROUND: Unruptured saccular intracranial aneurysm (SIA) is associated with an increased prevalence of migraine, but it is unclear whether this is altered by clipping of the aneurysm. The aim of our study was to determine whether remission rate of migraine and other recurrent headaches...... was greater in patients with SIA after clipping than in controls. METHODS: We prospectively studied 87 SIA patients with migraine or other recurrent headaches. They were interviewed about headaches in the preceding year before and 1 year after clipping using a validated semi-structured neurologist conducted...

  9. Prophylactic clipping for the prevention of bleeding following wide-field endoscopic mucosal resection of laterally spreading colorectal lesions: an economic modeling study.

    Science.gov (United States)

    Bahin, Farzan F; Rasouli, Khalid N; Williams, Stephen J; Lee, Eric Y T; Bourke, Michael J

    2016-08-01

    Clinically significant bleeding (CSPEB) is the most common adverse event following endoscopic mucosal resection (EMR) of large sessile and laterally spreading colorectal lesions (LSLs), and is associated with morbidity and resource utilization. CSPEB occurs more frequently with proximal LSLs. Prophylactic clipping of the post-EMR defect may be beneficial in CSPEB prevention. The aim of this study was to determine the cost-effectiveness of a prophylactic clipping strategy. We hypothesized that prophylactic clipping in the proximal colon was cost-effective. An economic model was applied to outcomes from the Australian Colonic Endoscopic Mucosal Resection (ACE) Study. Clip distances of 3, 5, 8, and 10 mm were analyzed. The cost of treating CSPEB was determined from an independent costing agency. The funds needed to spend (FNS) was the cost incurred in order to prevent one episode of CSPEB. A break-even analysis was performed to determine cost equivalence of the costs of clipping and CSPEB. Outcomes of 1717 LSLs (mean size 35.8 mm; 52.6 % proximal colon) that underwent EMR were analyzed. The overall rate of CSPEB was 6.4 % (proximal 8.9 %; distal 3.7 %). Endoscopic management was required in 45 % of CSPEB episodes. With a clip distance of 3 mm, the expected cost of prophylactic clipping was € 1106 per lesion compared with € 157 per lesion for the expected cost of CSPEB without clipping. At 100 % clipping efficacy, the FNS was € 14 826 (proximal and distal lesions € 9309 and € 29 540, respectively). A clip price of € 10.35 was required for the cost of clipping to offset the cost of CSPEB. A prophylactic clipping strategy is not cost-effective and at present cannot be justified for all lesions or selectively for lesions in the proximal colon. ClinicalTrials.gov (NCT01368289). © Georg Thieme Verlag KG Stuttgart · New York.

  10. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  11. 21 CFR 882.4215 - Clip rack.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  12. Evaluation of kidney repair capacity using 99mTc-DMSA in ischemia/reperfusion injury models.

    Science.gov (United States)

    Kwak, Wonjung; Jang, Hee-Seong; Belay, Takele; Kim, Jinu; Ha, Yeong Su; Lee, Sang Woo; Ahn, Byeong-Cheol; Lee, Jaetae; Park, Kwon Moo; Yoo, Jeongsoo

    2011-03-04

    Quantitative (99m)Tc-DMSA renal uptake was studied in different renal ischemia/reperfusion (I/R) mice models for the assessment of renal repair capacity. Mice models of nephrectomy, uni- and bi-lateral I/R together with sham-operated mice were established. At 1h, 1d, 4d, 1, 2 and 3 wk after I/R, (99m)Tc-DMSA (27.7 ± 1.3 MBq) was injected via tail vein and after 3h post-injection, the mice were scanned for 30 min with pinhole equipped gamma camera. Higher uptake of (99m)Tc-DMSA was measured in normal kidneys of uni-lateral I/R model and nephrectomized kidney I/R model at 3 wk post-surgery. Comparing the restoration capacities of the affected kidneys of nephrectomy, uni- and bi-lateral I/R models, higher repair capacity was observed in the nephrectomized model followed by bi-lateral then uni-lateral models. The normal kidney may retard the restoration of damaged kidney in uni-lateral I/R model. Moreover, 3 wk after Uni-I/R, the size of injured kidney was significantly smaller than non-ischemic contralateral and sham operated kidneys, while nephrectomy I/R kidneys were significantly enlarged compared to all others at 3 wk post-surgery. Very strong correlation between (99m)Tc-DMSA uptake and weight of dissected kidneys in I/R models was observed. Consistent with (99m)Tc-DMSA uptake results, all histological results indicate that kidney recovery after injury is correlated with the amount of intact tubules and kidney sizes. In summary, our study showed good potentials of (99m)Tc-DMSA scan as a promising non-invasive method for evaluation of kidney restoration after I/R injuries. Interestingly, mice with Bi-I/R injury showed faster repair capacity than those with uni-I/R. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Intelligent tutoring using HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.; Pickering, Brad

    1990-01-01

    HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.

  14. Derivation of a Predictive Model for Graft Loss Following Acute Kidney Injury in Kidney Transplant Recipients.

    Science.gov (United States)

    Molnar, Amber O; van Walraven, Carl; Fergusson, Dean; Garg, Amit X; Knoll, Greg

    2017-01-01

    Acute kidney injury (AKI) is common in the kidney transplant population. To derive a multivariable survival model that predicts time to graft loss following AKI. Retrospective cohort study using health care administrative and laboratory databases. Southwestern Ontario (1999-2013) and Ottawa, Ontario, Canada (1996-2013). We included first-time kidney only transplant recipients who had a hospitalization with AKI 6 months or greater following transplant. AKI was defined using the Acute Kidney Injury Network criteria (stage 1 or greater). The first episode of AKI was included in the analysis. Graft loss was defined by return to dialysis or repeat kidney transplant. We performed a competing risk survival regression analysis using the Fine and Gray method and modified the model into a simple point system. Graft loss with death as a competing event was the primary outcome of interest. A total of 315 kidney transplant recipients who had a hospitalization with AKI 6 months or greater following transplant were included. The median (interquartile range) follow-up time was 6.7 (3.3-10.3) years. Graft loss occurred in 27.6% of the cohort. The final model included 6 variables associated with an increased risk of graft loss: younger age, increased severity of AKI, failure to recover from AKI, lower baseline estimated glomerular filtration rate, increased time from kidney transplant to AKI admission, and receipt of a kidney from a deceased donor. The risk score had a concordance probability of 0.75 (95% confidence interval [CI], 0.69-0.82). The predicted 5-year risk of graft loss fell within the 95% CI of the observed risk more than 95% of the time. The CIs of the estimates were wide, and model overfitting is possible due to the limited sample size; the risk score requires validation to determine its clinical utility. Our prognostic risk score uses commonly available information to predict the risk of graft loss in kidney transplant patients hospitalized with AKI. If validated

  15. A method of handing down surgical clipping technique for cerebral aneurysm

    International Nuclear Information System (INIS)

    Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta

    2009-01-01

    Meticulous clipping techniques are essential to obtain good results. Recently, the introduction of intravascular surgery for cerebral aneurysms has decreased the number of the direct clipping surgeries. And the increasing number of the lawsuits against doctors further discourages young surgeons from attempting clipping. As a result, young neurosurgeons, have less experience performing clipping. Therefore, we must learn clipping techniques from expert neurosurgeons under the limitation of having fewer opportunities to perform clipping surgery. In this paper, I present my experiences and discuss ways to obtain techniques for clipping surgery. I performed surgical clipping in 19 cases, 12 unruptured and 7 ruptured aneurysms, 7 males and 12 females aged from 36 to 79 years old (mean 61.9 years). Postoperatively, there were no symptomatic complications, but there were 2 asymptomatic infarctions that were revealed on CT scan. Intraoperative premature rupture occurred in 1 patient with a ruptured aneurysm. Techniques of manipulation with micro-forceps, suction and spatula are required for successful clipping. Off-the-job training of dissecting chicken wing arteries and rat abdominal aortas and vena cavas is useful. Moreover, actual experiences of surgical operations are essential. Surgical experiences raise the motivation of young neurosurgeons and encourage them to train more. We believe that this benign cycle contributes to meticulous surgical skills. (author)

  16. Content-based video retrieval by example video clip

    Science.gov (United States)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  17. Vascular endothelial growth factor-A, matrix metalloproteinase-1, and macrophage migration inhibition factor changes in the porcine remnant kidney model: Evaluation by MRI

    Science.gov (United States)

    Misra, Sanjay; Misra, Khamal D; Glockner, James F.

    2010-01-01

    Purpose To determine the expression of vascular endothelial growth factor-A (VEGF-A), macrophage migration inhibition factor (MIF), and matrix metalloproteinase-1 (MMP-1) in the porcine remnant kidney model and quantify renal blood flow and volume using phase contrast magnetic resonance imaging with magnetic resonance angiography (PC MRI/MRA). Material and methods In 23 pigs, the left renal artery was completely embolized using polyvinyl acrylide (PVA) particles and the right kidney partially embolized (remnant kidney) while six pigs served as controls. The animals were sacrificed early (day 3, 7, and 14, N=3), day 24 (D24, N=5), day 37 (D37, N=3), day 42 (D42, N=9), and day 84 (D84, N=3). MRI/PC MRA of the kidneys was performed prior to sacrifice. The remnant and control kidneys were harvested for Western blotting of VEGF-A, MMP-1, and MIF. Blood was removed for BUN and creatinine prior to embolization and at time of sacrifice. Results The kidney function after the embolization was characterized by chronic renal insufficiency. The renal artery blood flow, volume, and weight of the remnant kidney increased significantly over time when compared to controls. At early time points, there was increased expression of MIF and MMP-1 followed by an increase in the expression of VEGF-A by day 37 (P<0.05 when compared to control). Masson's trichrome staining of the remnant kidney revealed scarring in the tubulointerstitial space. Conclusions In this model, renal blood flow and volume increase as the remnant kidney hypertrophies and scars. There is increased expression of MIF, VEGF-A, and MMP-1 in the remnant kidney. PMID:20610182

  18. CLIP Tool Kit (CTK): a flexible and robust pipeline to analyze CLIP sequencing data.

    Science.gov (United States)

    Shah, Ankeeta; Qian, Yingzhi; Weyn-Vanhentenryck, Sebastien M; Zhang, Chaolin

    2017-02-15

    UV cross-linking and immunoprecipitation (CLIP), followed by high-throughput sequencing, is a powerful biochemical assay that maps in vivo protein-RNA interactions on a genome-wide scale. The CLIP Tool Kit (CTK) aims at providing a set of tools for flexible, streamlined and comprehensive CLIP data analysis. This software package extends the scope of our original CIMS package. The software is implemented in Perl. The source code and detailed documentation are available at http://zhanglab.c2b2.columbia.edu/index.php/CTK . cz2294@columbia.edu. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  19. Clinical experience of titanium cerebral aneurysm clips. Evaluation of artifact of CT and MRI

    International Nuclear Information System (INIS)

    Ninomiya, Takashi; Kato, Yoko; Sano, Hirotoshi

    1996-01-01

    The titanium aneurysm clips manufactured by AESCULAP Company are expected to be useful, not only for clinical applications, but also for reducing artifacts in post-operative CT and MRI. We carried out an investigation of the behavior of the new Yasargil titanium clips in a 1.5T MR imager. The new titanium clips showed considerably smaller clip-induced MR and CT artifacts than phynox and elgiloy clips. No movement of the titanium clips was seen by introducing them to the MR imager. Subsequent to these experimental studies, we applied titanium clips to 25 cerebral aneurysms. Post-operative CT, especially helical scanning CT and MR showed minimal artifacts, leading to the conclusion that the titanium clips are better than the other types of clips for the evaluation of post-operative neuroradiological images. (author)

  20. Modified Clipped LMS Algorithm

    Directory of Open Access Journals (Sweden)

    Lotfizad Mojtaba

    2005-01-01

    Full Text Available Abstract A new algorithm is proposed for updating the weights of an adaptive filter. The proposed algorithm is a modification of an existing method, namely, the clipped LMS, and uses a three-level quantization ( scheme that involves the threshold clipping of the input signals in the filter weight update formula. Mathematical analysis shows the convergence of the filter weights to the optimum Wiener filter weights. Also, it can be proved that the proposed modified clipped LMS (MCLMS algorithm has better tracking than the LMS algorithm. In addition, this algorithm has reduced computational complexity relative to the unmodified one. By using a suitable threshold, it is possible to increase the tracking capability of the MCLMS algorithm compared to the LMS algorithm, but this causes slower convergence. Computer simulations confirm the mathematical analysis presented.

  1. Low Proteolytic Clipping of Histone H3 in Cervical Cancer

    Science.gov (United States)

    Sandoval-Basilio, Jorge; Serafín-Higuera, Nicolás; Reyes-Hernandez, Octavio D.; Serafín-Higuera, Idanya; Leija-Montoya, Gabriela; Blanco-Morales, Magali; Sierra-Martínez, Monica; Ramos-Mondragon, Roberto; García, Silvia; López-Hernández, Luz Berenice; Yocupicio-Monroy, Martha; Alcaraz-Estrada, Sofia L.

    2016-01-01

    Chromatin in cervical cancer (CC) undergoes chemical and structural changes that alter the expression pattern of genes. Recently, a potential mechanism, which regulates gene expression at transcriptional levels is the proteolytic clipping of histone H3. However, until now this process in CC has not been reported. Using HeLa cells as a model of CC and human samples from patients with CC, we identify that the H3 cleavage was lower in CC compared with control tissue. Additionally, the histone H3 clipping was performed by serine and aspartyl proteases in HeLa cells. These results suggest that histone H3 clipping operates as part of post-translational modification system in CC. PMID:27698925

  2. Sepsis from dropped clips at laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Hussain, Sarwat

    2001-01-01

    We report seven patients in whom five dropped surgical clips and two gallstones were visualized in the peritoneal cavity, on radiological studies. In two, subphrenic abscesses and empyemas developed as a result of dropped clips into the peritoneal cavity during or following laparoscopic cholecystectomy. In one of these two, a clip was removed surgically from the site of an abscess. In two other patients dropped gallstones, and in three, dropped clips led to no complications. These were seen incidentally on studies done for other indications. Abdominal abscess secondary to dropped gallstones is a well-recognized complication of laparoscopic cholecystectomy (LC). We conclude that even though dropped surgical clips usually do not cause problems, they should be considered as a risk additional to other well-known causes of post-LC abdominal sepsis

  3. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    Science.gov (United States)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  4. Removal time and efficacy of Riddell Quick Release Face Guard Attachment System side clips during 1 football season.

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    In the National Athletic Trainers' Association position statement, "Acute Management of the Cervical Spine-Injured Athlete," the technique recommended for face-mask (FM) removal is one that "creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure." Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Controlled laboratory study. College laboratory. A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation.

  5. Removal Time and Efficacy of Riddell Quick Release Face Guard Attachment System Side Clips During 1 Football Season

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    Context In the National Athletic Trainers' Association position statement, “Acute Management of the Cervical Spine-Injured Athlete,” the technique recommended for face-mask (FM) removal is one that “creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure.” Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. Objective To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Design Controlled laboratory study. Setting College laboratory. Patients or Other Participants A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Intervention(s) Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Main Outcome Measure(s) Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. Results The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Conclusions Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation. PMID:22889658

  6. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  7. Understanding Trends in Kidney Function 1 Year after Kidney Transplant in the United States.

    Science.gov (United States)

    Huang, Yihung; Tilea, Anca; Gillespie, Brenda; Shahinian, Vahakn; Banerjee, Tanushree; Grubbs, Vanessa; Powe, Neil; Rios-Burrows, Nilka; Pavkov, Meda; Saran, Rajiv

    2017-08-01

    Lower eGFR 1 year after kidney transplant is associated with shorter allograft and patient survival. We examined how practice changes in the past decade correlated with time trends in average eGFR at 1 year after kidney transplant in the United States in a cohort of 189,944 patients who received a kidney transplant between 2001 and 2013. We calculated the average eGFR at 1 year after transplant for the recipient cohort of each year using the appropriate Modification of Diet in Renal Disease equation depending on the prevailing methodology of creatinine measurement, and used linear regression to model the effects of practice changes on the national post-transplant eGFR trend. Between the 2001-2005 period and the 2011-2013 period, average 1-year post-transplant eGFR remained essentially unchanged, with differences of 1.34 (95% confidence interval, 1.03 to 1.65) ml/min per 1.73 m 2 and 0.66 (95% confidence interval, 0.32 to 1.01) ml/min per 1.73 m 2 among deceased and living donor kidney transplant recipients, respectively. Over time, the mean age of recipients increased and more marginal organs were used; adjusting for these trends unmasked a larger temporal improvement in post-transplant eGFR. However, changes in immunosuppression practice had a positive effect on average post-transplant eGFR and balanced out the negative effect of recipient/donor characteristics. In conclusion, average 1-year post-transplant eGFR remained stable, despite increasingly unfavorable attributes in recipients and donors. With an aging ESRD population and continued organ shortage, preservation of average post-transplant eGFR will require sustained improvement in immunosuppression and other aspects of post-transplant care. Copyright © 2017 by the American Society of Nephrology.

  8. Anesthesia management for MitraClip device implantation

    Directory of Open Access Journals (Sweden)

    Harikrishnan Kothandan

    2014-01-01

    Full Text Available Aims and Objectives: Percutaneous MitraClip implantation has been demonstrated as an alternative procedure in high-risk patients with symptomatic severe mitral regurgitation (MR who are not suitable (or denied mitral valve repair/replacement due to excessive co morbidity. The MitraClip implantation was performed under general anesthesia and with 3-dimensional transesophageal echocardiography (TEE and fluoroscopic guidance. Materials and Methods: Peri-operative patient data were extracted from the electronic and paper medical records of 21 patients who underwent MitraClip implantations. Results: Four MitraClip implantation were performed in the catheterization laboratory; remaining 17 were performed in the hybrid operating theatre. In 2 patients, procedure was aborted, in one due to migration of the Chiari network into the left atrium and in second one, the leaflets and chords of the mitral valve torn during clipping resulting in consideration for open surgery. In the remaining 19 patients, MitraClip was implanted and the patients showed acute reduction of severe MR to mild-moderate MR. All the patients had invasive blood pressure monitoring and the initial six patients had central venous catheterization prior to the procedure. Intravenous heparin was administered after the guiding catheter was introduced through the inter-atrial septum and activated clotting time was maintained beyond 250 s throughout the procedure. Protamine was administered at the end of the procedure. All the patients were monitored in the intensive care unit after the procedure. Conclusions: Percutaneous MitraClip implantation is a feasible alternative in high-risk patients with symptomatic severe MR. Anesthesia management requirements are similar to open surgical mitral valve repair or replacement. TEE plays a vital role during the MitraClip implantation.

  9. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  10. Osr1 Interacts Synergistically with Wt1 to Regulate Kidney Organogenesis.

    Directory of Open Access Journals (Sweden)

    Jingyue Xu

    Full Text Available Renal hypoplasia is a common cause of pediatric renal failure and several adult-onset diseases. Recent studies have associated a variant of the OSR1 gene with reduction of newborn kidney size and function in heterozygotes and neonatal lethality with kidney defects in homozygotes. How OSR1 regulates kidney development and nephron endowment is not well understood, however. In this study, by using the recently developed CRISPR genome editing technology, we genetically labeled the endogenous Osr1 protein and show that Osr1 interacts with Wt1 in the developing kidney. Whereas mice heterozygous for either an Osr1 or Wt1 null allele have normal kidneys at birth, most mice heterozygous for both Osr1 and Wt1 exhibit defects in metanephric kidney development, including unilateral or bilateral kidney agenesis or hypoplasia. The developmental defects in the Osr1+/-Wt1+/- mouse embryos were detected as early as E10.5, during specification of the metanephric mesenchyme, with the Osr1+/-Wt1+/- mouse embryos exhibiting significantly reduced Pax2-positive and Six2-positive nephron progenitor cells. Moreover, expression of Gdnf, the major nephrogenic signal for inducing ureteric bud outgrowth, was significantly reduced in the metanephric mesenchyme in Osr1+/-Wt1+/- embryos in comparison with the Osr1+/- or Wt1+/- littermates. By E11.5, as the ureteric buds invade the metanephric mesenchyme and initiate branching morphogenesis, kidney morphogenesis was significantly impaired in the Osr1+/-Wt1+/- embryos in comparison with the Osr1+/- or Wt1+/- embryos. These results indicate that Osr1 and Wt1 act synergistically to regulate nephron endowment by controlling metanephric mesenchyme specification during early nephrogenesis.

  11. Surgical Clipping versus Endovascular Intervention for the Treatment of Subarachnoid Hemorrhage Patients in New York State.

    Directory of Open Access Journals (Sweden)

    Kimon Bekelis

    Full Text Available Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH patients in a real-world regional cohort.We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009-2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.Of the 4,098 patients undergoing treatment, 2,585 (63.1% underwent coiling, and 1,513 (36.9% underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME, -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS (ME, 1.72; 95% CI, -3.39 to 6.84, or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22 between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01. In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.

  12. The role of SIRT1 in diabetic kidney disease

    Directory of Open Access Journals (Sweden)

    Rabi eYacoub

    2014-10-01

    Full Text Available Sirtuins (SIRTs are members of the silent information regulator 2 (Sir2 family. In mammals, of the seven known SIRTs, SIRT1 function is most studied and has been shown to regulate wide range of cellular functions that affect metabolic homeostasis and aging. SIRT1 exerts anti-apoptotic, anti-oxidative, and anti-inflammatory effects against cellular injury, and protects the cells through the regulation of mitochondrial biogenesis, autophagy, and metabolism in response to the cellular energy and redox status. SIRT1 also promotes vasodilation and protects vascular tissues. In humans and animal models with diabetic kidney disease, its expression tends to be decreased in renal cells, and increased expression of SIRT1 was found to play a renal protective role in animal models with diabetic kidney disease. In this review we discuss the role and potential mechanisms by which SIRT1 protects against DKD.

  13. Dual Selectivity Expressed in [2+2+1] Dynamic Clipping of Unsymmetrical [2]Catenanes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi

    2010-06-11

    A {pi}-templated dynamic [2+2+1] clipping protocol is established for the synthesis of [2]catenanes from two parts dialdehyde, two parts diamine and one part tetracationic cyclophane. It is further diversified for the selective formation of an unsymmetrical [2]catenane showing great translational selectivity by employing two different dialdehydes in a one-pot reaction. The dual selectivity and the dynamic nature are verified by {sup 1}H NMR spectroscopy, X-ray single crystal structural studies and exchange experiments.

  14. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy.

    Science.gov (United States)

    Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson

    2017-06-01

    Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Dynamic changes in Bach1 expression in the kidney of rhabdomyolysis-associated acute kidney injury.

    Directory of Open Access Journals (Sweden)

    Masakazu Yamaoka

    Full Text Available Free heme, a pro-oxidant released from myoglobin, is thought to contribute to the pathogenesis of rhabdomyolysis-associated acute kidney injury (RM-AKI, because renal overexpression of heme oxygenase-1 (HO-1, the rate-limiting enzyme in heme catabolism, confers protection against RM-AKI. BTB and CNC homology 1 (Bach1 is a heme-responsive transcription factor that represses HO-1. Here, we examined the changes with time in the gene expression of Bach1, HO-1, and δ-aminolevulinate synthase (ALAS1, a heme biosynthetic enzyme in the rat kidney using an RM-AKI model induced by the injection of 50% glycerol (10 mL/kg body weight into bilateral limbs. We also examined the protein expression of Bach1 in the nucleus and cytosol, and HO-1 in the rat kidney. Glycerol treatment induced significant elevation of serum creatinine kinase and aspartate aminotransferase levels followed by the marked elevation of serum blood urea nitrogen and creatinine levels, which caused serious damage to renal tubules. Following glycerol treatment, HO-1 mRNA and protein levels were significantly up-regulated, while ALAS1 mRNA expression was down-regulated, suggesting an increase in the free renal heme concentration. The Bach1 mRNA level was drastically increased 3 h after glycerol treatment, and the increased level was maintained for 12 h. Nuclear Bach1 protein levels were significantly decreased 3 h after treatment. Conversely, cytosolic Bach1 protein levels abruptly increased after 6 h. In conclusion, we demonstrate the dynamic changes in Bach1 expression in a rat model of RM-AKI. Our findings suggest that the increase in Bach1 mRNA and cytosolic Bach1 protein expression may reflect de novo Bach1 protein synthesis to compensate for the depletion of nuclear Bach1 protein caused by the induction of HO-1 by free heme.

  16. Journal of Clipped Words in Reader's Digest Magazine

    OpenAIRE

    Simanjuntak, Lestari

    2012-01-01

    This study deals with Clipped Words in the “Laughter, the Best Medicine” of Reader's Digest. The objectives of the study are to find out the types of clipped words which are used in the “Laughter, the Best Medicine” of Reader's Digest, to find out sthe dominantly used in the whole story and to reason the dominant clipped word use in the text. The study use descriptive qualitative method. The data were collected from seventeen selected Reader's Digest which contains the clipped word by applie...

  17. The role of vascular protein and renin in chronic two-kidney, one clip Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nakada, T.; Yamori, Y.

    1982-01-01

    Chronic hypertension was induced in rats by application of a clip for 17 or 20 weeks to the unilateral renal artery and leaving the contrarenal vessel intact. Some of the rats received antihypertensive treatment with phenoxybenzamine (POB). 3 H-proline was injected into all rats in the 17th experimental week to observe the in vivo incorporation rates of 3 H-proline into vascular non-collagenous protein and vascular collagen. Plasma renin activity (PRA) of decapitated rats was assayed in the terminal stage of the experiment. Significant differences were noted between 2K-1C hypertensive rats and sham-operated normotensive rats, the former rats having significantly higher incorporation rates of 3 H-proline into non-collagenous protein and collagen of testicular or mesenteric artery. These results indicate that increased synthesis of vascular non-collagenous protein as well as collagen, especially of small arteries, plays a major role for the pathogenesis of chronic hypertension in 2K-1C rats, and renin does not contribute to elevation of the blood pressure in the maintenance phase of this type of experimental hypertension

  18. 21 CFR 868.6225 - Nose clip.

    Science.gov (United States)

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  19. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  20. Kidney Modelling for FDG Excretion with PET

    Directory of Open Access Journals (Sweden)

    Huiting Qiao

    2007-01-01

    Full Text Available The purpose of this study was to detect the physiological process of FDG's filtration from blood to urine and to establish a mathematical model to describe the process. Dynamic positron emission tomography scan for FDG was performed on seven normal volunteers. The filtration process in kidney can be seen in the sequential images of each study. Variational distribution of FDG in kidney can be detected in dynamic data. According to the structure and function, kidney is divided into parenchyma and pelvis. A unidirectional three-compartment model is proposed to describe the renal function in FDG excretion. The time-activity curves that were picked up from the parenchyma, pelvis, and abdominal aorta were used to estimate the parameter of the model. The output of the model has fitted well with the original curve from dynamic data.

  1. Modeling Kidney Disease with iPS Cells

    Science.gov (United States)

    Freedman, Benjamin S.

    2015-01-01

    Induced pluripotent stem cells (iPSCs) are somatic cells that have been transcriptionally reprogrammed to an embryonic stem cell (ESC)-like state. iPSCs are a renewable source of diverse somatic cell types and tissues matching the original patient, including nephron-like kidney organoids. iPSCs have been derived representing several kidney disorders, such as ADPKD, ARPKD, Alport syndrome, and lupus nephritis, with the goals of generating replacement tissue and ‘disease in a dish’ laboratory models. Cellular defects in iPSCs and derived kidney organoids provide functional, personalized biomarkers, which can be correlated with genetic and clinical information. In proof of principle, disease-specific phenotypes have been described in iPSCs and ESCs with mutations linked to polycystic kidney disease or focal segmental glomerulosclerosis. In addition, these cells can be used to model nephrotoxic chemical injury. Recent advances in directed differentiation and CRISPR genome editing enable more specific iPSC models and present new possibilities for diagnostics, disease modeling, therapeutic screens, and tissue regeneration using human cells. This review outlines growth opportunities and design strategies for this rapidly expanding and evolving field. PMID:26740740

  2. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  3. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  4. Identification of CELF1 RNA targets by CLIP-seq in human HeLa cells

    Directory of Open Access Journals (Sweden)

    Olivier Le Tonquèze

    2016-06-01

    Full Text Available The specific interactions between RNA-binding proteins and their target RNAs are an essential level to control gene expression. By combining ultra-violet cross-linking and immunoprecipitation (CLIP and massive SoliD sequencing we identified the RNAs bound by the RNA-binding protein CELF1, in human HeLa cells. The CELF1 binding sites deduced from the sequence data allow characterizing specific features of CELF1-RNA association. We present therefore the first map of CELF1 binding sites in human cells.

  5. The OTSC®-clip in revisional endoscopy against weight gain after bariatric gastric bypass surgery.

    Science.gov (United States)

    Heylen, Alex Marie Florent; Jacobs, Anja; Lybeer, Monika; Prosst, Ruediger L

    2011-10-01

    The maintenance of the restrictive component of the Fobi pouch gastric bypass is essential for permanent weight control. Dilatation of the pouch-outlet and of the pouch itself is responsible for substantial weight gain by an increased volume per meal and binge-eating due to the rapid emptying. An endoscopic over-the-scope clip (OTSC®; Ovesco AG, Tübingen, Germany) was applied in 94 patients following gastric bypass and unintended weight gain by dilated gastro-jejunostomy to narrow the pouch-outlet. The OTSC®-clip application was safe and efficient to reduce the pouch-outlet in all cases. Best clinical results were obtained by narrowing the gastro-jejunostomy by placing two clips at opposite sites, hence reducing the outlet of more than 80%. Preferably, the clip approximated the whole thickness of the wall to avoid further dilatation of the anastomosis. Between surgery and OTSC®-clip application the mean BMI dropped from 45.8 (±3.6) to 32.8 (±1.9). At the first follow-up about 3 months (mean 118 days, ±46 days) after OTSC®-clip application the mean BMI was 29.7 (±1.8). At the second follow-up about 1 year (mean 352 days, ±66 days) after OTSC®-clip application the mean BMI was 27.4 (±3.8). The OTSC®-clip for revisional endoscopy after gastric bypass is reliable and effective in treating weight gain due to a dilated pouch-outlet with favorable short- and midterm results.

  6. Chinese Language Video Clips. [CD-ROM].

    Science.gov (United States)

    Fleming, Stephen; Hipley, David; Ning, Cynthia

    This compact disc includes video clips covering six topics for the learner of Chinese: personal information, commercial transactions, travel and leisure, health and sports, food and school. Filmed on location in Beijing, these naturalistic video clips consist mainly of unrehearsed interviews of ordinary people. The learner is lead through a series…

  7. Portable x-ray fluorescence for the analysis of chromium in nail and nail clippings

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Ware, Chris S.

    2017-01-01

    Assessment of chromium content in human nail or nail clippings could serve as an effective biomarker of chromium status. The feasibility of a new portable x-ray fluorescence (XRF) approach to chromium measurement was investigated through analysis of nail and nail clipping phantoms. Five measurements of 180 s (real time) duration were first performed on six whole nail phantoms having chromium concentrations of 0, 2, 5, 10, 15, and 20 µg/g. Using nail clippers, these phantoms were then converted to nail clippings, and assembled into different mass groups of 20, 40, 60, 80, and 100 mg for additional measurements. The amplitude of the chromium Kα characteristic x-ray energy peak was examined as a function of phantom concentration for all measurement conditions to create a series of calibration lines. The minimum detection limit (MDL) for chromium was also calculated for each case. The chromium MDL determined from the whole nail intact phantoms was 0.88±0.03 µg/g. For the clipping phantoms, the MDL ranged from 1.2 to 3.3 µg/g, depending on the mass group analyzed. For the 40 mg clipping group, the MDL was 1.2±0.1 µg/g, and higher mass collections did not improve upon this result. This MDL is comparable to chromium concentration levels seen in various studies involving human nail clippings. Further improvements to the portable XRF technique would be required to detect chromium levels expected from the lower end of a typical population. - Highlights: • Portable x-ray fluorescence (XRF) was explored as a technique to assess levels of chromium in human nails or nail clippings. • Results were found to depend on the mass of clipping sample provided. • Minimum detection limits for chromium were similar to concentration levels found in previous studies of human nail clippings.

  8. Chemokine receptor Ccr1 drives neutrophil-mediated kidney immunopathology and mortality in invasive candidiasis.

    Directory of Open Access Journals (Sweden)

    Michail S Lionakis

    Full Text Available Invasive candidiasis is the 4(th leading cause of nosocomial bloodstream infection in the US with mortality that exceeds 40% despite administration of antifungal therapy; neutropenia is a major risk factor for poor outcome after invasive candidiasis. In a fatal mouse model of invasive candidiasis that mimics human bloodstream-derived invasive candidiasis, the most highly infected organ is the kidney and neutrophils are the major cellular mediators of host defense; however, factors regulating neutrophil recruitment have not been previously defined. Here we show that mice lacking chemokine receptor Ccr1, which is widely expressed on leukocytes, had selectively impaired accumulation of neutrophils in the kidney limited to the late phase of the time course of the model; surprisingly, this was associated with improved renal function and survival without affecting tissue fungal burden. Consistent with this, neutrophils from wild-type mice in blood and kidney switched from Ccr1(lo to Ccr1(high at late time-points post-infection, when Ccr1 ligands were produced at high levels in the kidney and were chemotactic for kidney neutrophils ex vivo. Further, when a 11 mixture of Ccr1(+/+ and Ccr1(-/- donor neutrophils was adoptively transferred intravenously into Candida-infected Ccr1(+/+ recipient mice, neutrophil trafficking into the kidney was significantly skewed toward Ccr1(+/+ cells. Thus, neutrophil Ccr1 amplifies late renal immunopathology and increases mortality in invasive candidiasis by mediating excessive recruitment of neutrophils from the blood to the target organ.

  9. Kidney injury molecule-1 in renal disease

    NARCIS (Netherlands)

    Waanders, Femke; van Timmeren, Mirjan M.; Stegeman, Coen A.; Bakker, Stephan J. L.; van Goor, Harry

    Kidney injury molecule-1 (KIM-1) is a marker for renal proximal tubular damage, the hallmark of virtually all proteinuric, toxic and ischaemic kidney diseases. KIM-1 has gained increasing interest because of its possible pathophysiological role in modulating tubular damage and repair. In this

  10. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    Science.gov (United States)

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  11. Kidney adysplasia and variable hydronephrosis, a new mutation affecting the odd-skipped related 1 gene in the mouse, causes variable defects in kidney development and hydronephrosis.

    Science.gov (United States)

    Davisson, Muriel T; Cook, Susan A; Akeson, Ellen C; Liu, Don; Heffner, Caleb; Gudis, Polyxeni; Fairfield, Heather; Murray, Stephen A

    2015-06-15

    Many genes, including odd-skipped related 1 (Osr1), are involved in regulation of mammalian kidney development. We describe here a new recessive mutation (kidney adysplasia and variable hydronephrosis, kavh) in the mouse that leads to downregulation of Osr1 transcript, causing several kidney defects: agenesis, hypoplasia, and hydronephrosis with variable age of onset. The mutation is closely associated with a reciprocal translocation, T(12;17)4Rk, whose Chromosome 12 breakpoint is upstream from Osr1. The kavh/kavh mutant provides a model to study kidney development and test therapies for hydronephrosis. Copyright © 2015 the American Physiological Society.

  12. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  13. Digital video clips for improved pedagogy and illustration of scientific research — with illustrative video clips on atomic spectrometry

    Science.gov (United States)

    Michel, Robert G.; Cavallari, Jennifer M.; Znamenskaia, Elena; Yang, Karl X.; Sun, Tao; Bent, Gary

    1999-12-01

    This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15-30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as 'live' demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.

  14. APOL1 Oligomerization as the Key Mediator of Kidney Disease in African Americans

    Science.gov (United States)

    2016-10-01

    protein in an amyloid-like process. We are testing this hypothesis in in vitro systems, cells, and model systems using molecular biology, biochemistry ...human kidney biopsy specimens using molecular biology, biochemistry , protein chemistry, and microscopy-based approaches. 2. KEYWORDS: Kidney, ESRD...presence of Thioflavin T a. Test both (1) APOL1 holoprotein and (2) amyloidogenic ApoL1 fragments b. Repeat, varying concentration, time, pH , and

  15. Chemokine Receptor Ccr1 Drives Neutrophil-Mediated Kidney Immunopathology and Mortality in Invasive Candidiasis

    Science.gov (United States)

    Lionakis, Michail S.; Swamydas, Muthulekha; Wan, Wuzhou; Richard Lee, Chyi-Chia; Cohen, Jeffrey I.; Scheinberg, Phillip; Gao, Ji-Liang; Murphy, Philip M.

    2012-01-01

    Invasive candidiasis is the 4th leading cause of nosocomial bloodstream infection in the US with mortality that exceeds 40% despite administration of antifungal therapy; neutropenia is a major risk factor for poor outcome after invasive candidiasis. In a fatal mouse model of invasive candidiasis that mimics human bloodstream-derived invasive candidiasis, the most highly infected organ is the kidney and neutrophils are the major cellular mediators of host defense; however, factors regulating neutrophil recruitment have not been previously defined. Here we show that mice lacking chemokine receptor Ccr1, which is widely expressed on leukocytes, had selectively impaired accumulation of neutrophils in the kidney limited to the late phase of the time course of the model; surprisingly, this was associated with improved renal function and survival without affecting tissue fungal burden. Consistent with this, neutrophils from wild-type mice in blood and kidney switched from Ccr1lo to Ccr1high at late time-points post-infection, when Ccr1 ligands were produced at high levels in the kidney and were chemotactic for kidney neutrophils ex vivo. Further, when a 11 mixture of Ccr1+/+ and Ccr1−/− donor neutrophils was adoptively transferred intravenously into Candida-infected Ccr1+/+ recipient mice, neutrophil trafficking into the kidney was significantly skewed toward Ccr1+/+ cells. Thus, neutrophil Ccr1 amplifies late renal immunopathology and increases mortality in invasive candidiasis by mediating excessive recruitment of neutrophils from the blood to the target organ. PMID:22916017

  16. Effects of Japanese beetle (Coleoptera: Scarabaeidae) and silk clipping in field corn.

    Science.gov (United States)

    Steckel, Sandy; Stewart, S D; Tindall, K V

    2013-10-01

    Japanese beetle (Popillia japonica Newman) is an emerging silk-feeding insect found in fields in the lower Corn Belt and Midsouthern United States. Studies were conducted in 2010 and 2011 to evaluate how silk clipping in corn affects pollination and yield parameters. Manually clipping silks once daily had modest effects on yield parameters. Sustained clipping by either manually clipping silks three times per day or by caging Japanese beetles onto ears affected total kernel weight if it occurred during early silking (R1 growth stage). Manually clipping silks three times per day for the first 5 d of silking affected the number of kernels per ear, total kernel weight, and the weight of individual kernels. Caged beetles fed on silks and, depending on the number of beetles caged per ear, reduced the number of kernels per ear. Caging eight beetles per ear significantly reduced total kernel weight compared with noninfested ears. Drought stress before anthesis appeared to magnify the impact of silk clipping by Japanese beetles. There was evidence of some compensation for reduced pollination by increasing the size of pollinated kernels within the ear. Our results showed that it requires sustained silk clipping during the first week of silking to have substantial impacts on pollination and yield parameters, at least under good growing conditions. Some states recommend treating for Japanese beetle when three Japanese beetles per ear are found, silks are clipped to < 13 mm, and pollination is < 50% complete, and that recommendation appears to be adequate.

  17. Integrating CLIPS applications into heterogeneous distributed systems

    Science.gov (United States)

    Adler, Richard M.

    1991-01-01

    SOCIAL is an advanced, object-oriented development tool for integrating intelligent and conventional applications across heterogeneous hardware and software platforms. SOCIAL defines a family of 'wrapper' objects called agents, which incorporate predefined capabilities for distributed communication and control. Developers embed applications within agents and establish interactions between distributed agents via non-intrusive message-based interfaces. This paper describes a predefined SOCIAL agent that is specialized for integrating C Language Integrated Production System (CLIPS)-based applications. The agent's high-level Application Programming Interface supports bidirectional flow of data, knowledge, and commands to other agents, enabling CLIPS applications to initiate interactions autonomously, and respond to requests and results from heterogeneous remote systems. The design and operation of CLIPS agents are illustrated with two distributed applications that integrate CLIPS-based expert systems with other intelligent systems for isolating and mapping problems in the Space Shuttle Launch Processing System at the NASA Kennedy Space Center.

  18. Pathogenic sequence for dissecting aneurysm formation in a hypomorphic polycystic kidney disease 1 mouse model

    NARCIS (Netherlands)

    Hassane, S.; Claij, N.; Lantinga-van Leeuwen, I.S.; Munsteren, J.C. van; Lent, N. van; Hanemaaijer, R.; Breuning, M.H.; Peters, D.J.M.; Ruiter, M.C. de

    2007-01-01

    OBJECTIVE - Autosomal Dominant Polycystic Kidney Disease (ADPKD) is a multi-system disorder characterized by progressive cyst formation in the kidneys. Serious complications of ADPKD are intracranial and aortic aneurysms. The condition is mainly caused by mutations in the PKD1 or PKD2 gene. We have

  19. Phosphorus runoff from turfgrass as affected by phosphorus fertilization and clipping management.

    Science.gov (United States)

    Bierman, Peter M; Horgan, Brian P; Rosen, Carl J; Hollman, Andrew B; Pagliari, Paulo H

    2010-01-01

    Phosphorus enrichment of surface water is a concern in many urban watersheds. A 3-yr study on a silt loam soil with 5% slope and high soil test P (27 mg kg(-1) Bray P1) was conducted to evaluate P fertilization and clipping management effects on P runoff from turfgrass (Poa pratensis L.) under frozen and nonfrozen conditions. Four fertilizer treatments were compared: (i) no fertilizer, (ii) nitrogen (N)+potassium (K)+0xP, (iii) N+K+1xP, and (iv) N+K+3xP. Phosphorus rates were 21.3 and 63.9 kg ha(-1) yr(-1) the first year and 7.1 and 21.3 kg ha(-1) yr(-1) the following 2 yr. Each fertilizer treatment was evaluated with clippings removed or clippings recycled back to the turf. In the first year, P runoff increased with increasing P rate and P losses were greater in runoff from frozen than nonfrozen soil. In year 2, total P runoff from the no fertilizer treatment was greater than from treatments receiving fertilizer. This was because reduced turf quality resulted in greater runoff depth from the no fertilizer treatment. In year 3, total P runoff from frozen soil and cumulative total P runoff increased with increasing P rate. Clipping management was not an important factor in any year, indicating that returning clippings does not significantly increase P runoff from turf. In the presence of N and K, P fertilization did not improve turf growth or quality in any year. Phosphorus runoff can be reduced by not applying P to high testing soils and avoiding fall applications when P is needed.

  20. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  1. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  2. Percutaneous interventional mitral regurgitation treatment using the Mitra-Clip system

    DEFF Research Database (Denmark)

    Boekstegers, P; Hausleiter, J; Baldus, S

    2014-01-01

    The interventional treatment of mitral valve regurgitation by the MitraClip procedure has grown rapidly in Germany and Europe during the past years. The MitraClip procedure has the potential to treat high-risk patients with secondary mitral valve regurgitation and poor left ventricular function....... Furthermore, patients with primary mitral valve regurgitation may be treated successfully by the MitraClip procedure in case of high surgical risk or in very old patients. At the same time it has been emphasised that the MitraClip interventional treatment is still at an early stage of clinical development....... The largest clinical experience with the MitraClip procedure so far is probably present in some German cardiovascular centers, which here summarise their recommendations on the current indications and procedural steps of the MitraClip treatment. These recommendations of the AGIK and ALKK may present a basis...

  3. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    Science.gov (United States)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  4. A Sieving ANN for Emotion-Based Movie Clip Classification

    Science.gov (United States)

    Watanapa, Saowaluk C.; Thipakorn, Bundit; Charoenkitkarn, Nipon

    Effective classification and analysis of semantic contents are very important for the content-based indexing and retrieval of video database. Our research attempts to classify movie clips into three groups of commonly elicited emotions, namely excitement, joy and sadness, based on a set of abstract-level semantic features extracted from the film sequence. In particular, these features consist of six visual and audio measures grounded on the artistic film theories. A unique sieving-structured neural network is proposed to be the classifying model due to its robustness. The performance of the proposed model is tested with 101 movie clips excerpted from 24 award-winning and well-known Hollywood feature films. The experimental result of 97.8% correct classification rate, measured against the collected human-judges, indicates the great potential of using abstract-level semantic features as an engineered tool for the application of video-content retrieval/indexing.

  5. Hardware Implementation Of Line Clipping A lgorithm By Using FPGA

    Directory of Open Access Journals (Sweden)

    Amar Dawod

    2013-04-01

    Full Text Available The computer graphics system performance is increasing faster than any other computing application. Algorithms for line clipping against convex polygons and lines have been studied for a long time and many research papers have been published so far. In spite of the latest graphical hardware development and significant increase of performance the clipping is still a bottleneck of any graphical system. So its implementation in hardware is essential for real time applications. In this paper clipping operation is discussed and a hardware implementation of the line clipping algorithm is presented and finally formulated and tested using Field Programmable Gate Arrays (FPGA. The designed hardware unit consists of two parts : the first is positional code generator unit and the second is the clipping unit. Finally it is worth mentioning that the  designed unit is capable of clipping (232524 line segments per second.       

  6. Speed Biases With Real-Life Video Clips

    Directory of Open Access Journals (Sweden)

    Federica Rossi

    2018-03-01

    Full Text Available We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion, speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion to 32% (physical motion. Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing.

  7. Semantic Labeling of Nonspeech Audio Clips

    Directory of Open Access Journals (Sweden)

    Xiaojuan Ma

    2010-01-01

    Full Text Available Human communication about entities and events is primarily linguistic in nature. While visual representations of information are shown to be highly effective as well, relatively little is known about the communicative power of auditory nonlinguistic representations. We created a collection of short nonlinguistic auditory clips encoding familiar human activities, objects, animals, natural phenomena, machinery, and social scenes. We presented these sounds to a broad spectrum of anonymous human workers using Amazon Mechanical Turk and collected verbal sound labels. We analyzed the human labels in terms of their lexical and semantic properties to ascertain that the audio clips do evoke the information suggested by their pre-defined captions. We then measured the agreement with the semantically compatible labels for each sound clip. Finally, we examined which kinds of entities and events, when captured by nonlinguistic acoustic clips, appear to be well-suited to elicit information for communication, and which ones are less discriminable. Our work is set against the broader goal of creating resources that facilitate communication for people with some types of language loss. Furthermore, our data should prove useful for future research in machine analysis/synthesis of audio, such as computational auditory scene analysis, and annotating/querying large collections of sound effects.

  8. Clip, connect, clone

    DEFF Research Database (Denmark)

    Fujima, Jun; Lunzer, Aran; Hornbæk, Kasper

    2010-01-01

    using three mechanisms: clipping of input and result elements from existing applications to form cells on a spreadsheet; connecting these cells using formulas, thus enabling result transfer between applications; and cloning cells so that multiple requests can be handled side by side. We demonstrate...

  9. Restoration of Haemoglobin Level Using Hydrodynamic Gene Therapy with Erythropoietin Does Not Alleviate the Disease Progression in an Anaemic Mouse Model for TGFβ1-Induced Chronic Kidney Disease

    DEFF Research Database (Denmark)

    Pedersen, Lea Hougaard; Wogensen, Lise; Marcussen, N.

    2015-01-01

    . The experiment is conducted by hydrodynamic gene transfer of a plasmid encoding murine Epo in a transgenic mouse model that overexpresses TGF-β1 locally in the kidneys. This model develops anaemia due to chronic kidney disease characterised by thickening of the glomerular basement membrane, deposition...... of mesangial matrix and mild interstitial fibrosis. A group of age matched wildtype littermates are treated accordingly. After a single hydrodynamic administration of plasmid DNA containing murine EPO gene, sustained high haemoglobin levels are observed in both transgenic and wildtype mice from 7.5 ± 0.6 mmol...... treatment in this model of chronic kidney disease normalises haemoglobin levels but has no effect on kidney fibrosis or function....

  10. Appraisal of the porcine kidney autotransplantation model

    NARCIS (Netherlands)

    Post, Ivo C. J. H.; Dirkes, Marcel C.; Heger, Michal; van Loon, Johannes P. A. M.; Swildens, Bas; Huijzer, Goos M.; van Gulik, Thomas M.

    2012-01-01

    Animal models are extensively used for transplantation related research, especially kidney transplantation. Porcine autotransplantation models are considered to be favorable regarding translatability to the human setting. The key determinants for translatability of the model are discussed,

  11. Segmentation of kidney using C-V model and anatomy priors

    Science.gov (United States)

    Lu, Jinghua; Chen, Jie; Zhang, Juan; Yang, Wenjia

    2007-12-01

    This paper presents an approach for kidney segmentation on abdominal CT images as the first step of a virtual reality surgery system. Segmentation for medical images is often challenging because of the objects' complicated anatomical structures, various gray levels, and unclear edges. A coarse to fine approach has been applied in the kidney segmentation using Chan-Vese model (C-V model) and anatomy prior knowledge. In pre-processing stage, the candidate kidney regions are located. Then C-V model formulated by level set method is applied in these smaller ROI, which can reduce the calculation complexity to a certain extent. At last, after some mathematical morphology procedures, the specified kidney structures have been extracted interactively with prior knowledge. The satisfying results on abdominal CT series show that the proposed approach keeps all the advantages of C-V model and overcome its disadvantages.

  12. Current MitraClip experience, safety and feasibility in the Netherlands

    NARCIS (Netherlands)

    Rahhab, Z.; Kortlandt, F. A.; Velu, J. F.; Schurer, R. A. J.; Delgado, V.; Tonino, P.; Boven, A. J.; van den Branden, B. J. L.; Kraaijeveld, A. O.; Voskuil, M.; Hoorntje, J.; van Wely, M. [=Marleen; van Houwelingen, K.; Bleeker, G. B.; Rensing, B.; Kardys, I.; Baan, J.; van der Heyden, J. A. S.; van Mieghem, N. M.

    2017-01-01

    Purpose Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. Methods We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by

  13. Collectin Liver 1 and Collectin Kidney 1 of the Lectin Complement Pathway Are Associated With Mortality After Kidney Transplantation

    DEFF Research Database (Denmark)

    Smedbråten, J; Sagedal, S; Åsberg, A

    2017-01-01

    Kidney transplanted patients still have significantly higher mortality compared with the general population. The innate immune system may play an important role during periods, with suppression of the adaptive immune system. In the present study, two soluble pattern recognition molecules of the i......Kidney transplanted patients still have significantly higher mortality compared with the general population. The innate immune system may play an important role during periods, with suppression of the adaptive immune system. In the present study, two soluble pattern recognition molecules...... of the innate immune system were investigated, collectin liver 1 (CL-L1) and collectin kidney 1 (CL-K1). Potential associations of their pretransplant levels and long-term graft and recipient survival were examined. The levels of CL-L1 and CL-K1 were measured at the time of transplantation in 382 patients (≥17...

  14. Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting.

    Science.gov (United States)

    Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H

    2016-04-01

    Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Loss of the BMP antagonist USAG-1 ameliorates disease in a mouse model of the progressive hereditary kidney disease Alport syndrome.

    Science.gov (United States)

    Tanaka, Mari; Asada, Misako; Higashi, Atsuko Y; Nakamura, Jin; Oguchi, Akiko; Tomita, Mayumi; Yamada, Sachiko; Asada, Nariaki; Takase, Masayuki; Okuda, Tomohiko; Kawachi, Hiroshi; Economides, Aris N; Robertson, Elizabeth; Takahashi, Satoru; Sakurai, Takeshi; Goldschmeding, Roel; Muso, Eri; Fukatsu, Atsushi; Kita, Toru; Yanagita, Motoko

    2010-03-01

    The glomerular basement membrane (GBM) is a key component of the filtering unit in the kidney. Mutations involving any of the collagen IV genes (COL4A3, COL4A4, and COL4A5) affect GBM assembly and cause Alport syndrome, a progressive hereditary kidney disease with no definitive therapy. Previously, we have demonstrated that the bone morphogenetic protein (BMP) antagonist uterine sensitization-associated gene-1 (USAG-1) negatively regulates the renoprotective action of BMP-7 in a mouse model of tubular injury during acute renal failure. Here, we investigated the role of USAG-1 in renal function in Col4a3-/- mice, which model Alport syndrome. Ablation of Usag1 in Col4a3-/- mice led to substantial attenuation of disease progression, normalization of GBM ultrastructure, preservation of renal function, and extension of life span. Immunohistochemical analysis revealed that USAG-1 and BMP-7 colocalized in the macula densa in the distal tubules, lying in direct contact with glomerular mesangial cells. Furthermore, in cultured mesangial cells, BMP-7 attenuated and USAG-1 enhanced the expression of MMP-12, a protease that may contribute to GBM degradation. These data suggest that the pathogenetic role of USAG-1 in Col4a3-/- mice might involve crosstalk between kidney tubules and the glomerulus and that inhibition of USAG-1 may be a promising therapeutic approach for the treatment of Alport syndrome.

  16. Diagnostic applications of nail clippings.

    Science.gov (United States)

    Stephen, Sasha; Tosti, Antonella; Rubin, Adam I

    2015-04-01

    "Nail clipping is a simple technique for diagnosis of several nail unit dermatoses. This article summarizes the practical approach, utility, and histologic findings of a nail clipping in evaluation of onychomycosis, nail unit psoriasis, onychomatricoma, subungual hematoma, melanonychia, and nail cosmetics, and the forensic applications of this easily obtained specimen. It reviews important considerations in optimizing specimen collection, processing methods, and efficacy of special stains in several clinical contexts. Readers will develop a greater understanding and ease of application of this indispensable procedure in assessing nail unit dermatoses." Copyright © 2015 Elsevier Inc. All rights reserved.

  17. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    Science.gov (United States)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  18. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  19. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum

    2014-01-01

    Clipping is one of the simplest peak-to-average power ratio reduction schemes for orthogonal frequency division multiplexing (OFDM). Deliberately clipping the transmission signal degrades system performance, and clipping mitigation is required at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate and noise variance for enhanced recovery. At the same time, the proposed scheme is robust against inaccurate estimates of the clipping signal statistics. The undistorted phase property of the clipped signal, as well as the clipping likelihood, is utilized for enhanced reconstruction. Furthermore, motivated by the nature of modern OFDM-based communication systems, we extend our clipping reconstruction approach to multiple antenna receivers and multi-user OFDM.We also address the problem of channel estimation from pilots contaminated by the clipping distortion. Numerical findings are presented that depict favorable results for the proposed scheme compared to the established sparse reconstruction schemes.

  20. CLIPS/Ada: An Ada-based tool for building expert systems

    Science.gov (United States)

    White, W. A.

    1990-01-01

    Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.

  1. Microsurgery Simulator of Cerebral Aneurysm Clipping with Interactive Cerebral Deformation Featuring a Virtual Arachnoid.

    Science.gov (United States)

    Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2018-05-01

    A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.

  2. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...

  3. Graft function assessment in mouse models of single- and dual- kidney transplantation.

    Science.gov (United States)

    Wang, Lei; Wang, Ximing; Jiang, Shan; Wei, Jin; Buggs, Jacentha; Fu, Liying; Zhang, Jie; Liu, Ruisheng

    2018-05-23

    Animal models of kidney transplantation (KTX) are widely used in studying immune response of hosts to implanted grafts. Additionally, KTX can be used in generating kidney-specific knockout animal models by transplantation of kidneys from donors with global knockout of a gene to wild type recipients or vise verse. Dual kidney transplantation (DKT) provides a more physiological environment for recipients than single kidney transplantation (SKT). However, DKT in mice is rare due to technical challenges. In this study, we successfully performed DKT in mice and compared the hemodynamic response and graft function with SKT. The surgical time, complications and survival rate of DKT were not significantly different from SKT, where survival rates were above 85%. Mice with DKT showed less injury and quicker recovery with lower plasma creatinine (Pcr) and higher GFR than SKT mice (Pcr = 0.34 and 0.17 mg/dl in DKT vs. 0.50 and 0.36 mg/dl in SKT at 1 and 3 days, respectively; GFR = 215 and 131 µl/min for DKT and SKT, respectively). In addition, the DKT exhibited better renal functional reserve and long-term outcome of renal graft function than SKT based on the response to acute volume expansion. In conclusion, we have successfully generated a mouse DKT model. The hemodynamic responses of DKT better mimic physiological situations with less kidney injury and better recovery than SKT because of reduced confounding factors such as single nephron hyperfiltration. We anticipate DKT in mice will provide an additional tool for evaluation of renal significance in physiology and disease.

  4. Increased podocyte Sirtuin-1 function attenuates diabetic kidney injury.

    Science.gov (United States)

    Hong, Quan; Zhang, Lu; Das, Bhaskar; Li, Zhengzhe; Liu, Bohan; Cai, Guangyan; Chen, Xiangmei; Chuang, Peter Y; He, John Cijiang; Lee, Kyung

    2018-06-01

    Podocyte injury and loss contribute to the progression of glomerular diseases, including diabetic kidney disease. We previously found that the glomerular expression of Sirtuin-1 (SIRT1) is reduced in human diabetic glomeruli and that the podocyte-specific loss of SIRT1 aggravated albuminuria and worsened kidney disease progression in diabetic mice. SIRT1 encodes an NAD-dependent deacetylase that modifies the activity of key transcriptional regulators affected in diabetic kidneys, including NF-κB, STAT3, p53, FOXO4, and PGC1-α. However, whether the increased glomerular SIRT1 activity is sufficient to ameliorate the pathogenesis of diabetic kidney disease has not been explored. We addressed this by inducible podocyte-specific SIRT1 overexpression in diabetic OVE26 mice. The induction of SIRT1 overexpression in podocytes for six weeks in OVE26 mice with established albuminuria attenuated the progression of diabetic glomerulopathy. To further validate the therapeutic potential of increased SIRT1 activity against diabetic kidney disease, we developed a new, potent and selective SIRT1 agonist, BF175. In cultured podocytes BF175 increased SIRT1-mediated activation of PGC1-α and protected against high glucose-mediated mitochondrial injury. In vivo, administration of BF175 for six weeks in OVE26 mice resulted in a marked reduction in albuminuria and in glomerular injury in a manner similar to podocyte-specific SIRT1 overexpression. Both podocyte-specific SIRT1 overexpression and BT175 treatment attenuated diabetes-induced podocyte loss and reduced oxidative stress in glomeruli of OVE26 mice. Thus, increased SIRT1 activity protects against diabetes-induced podocyte injury and effectively mitigates the progression of diabetic kidney disease. Published by Elsevier Inc.

  5. 76 FR 42730 - Paper Clips From China

    Science.gov (United States)

    2011-07-19

    ... China Determination On the basis of the record \\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the...), entitled Paper Clips from China: Investigation No. 731-TA-663 (Third Review). By order of the Commission...

  6. Heavy metal phytoextraction by Sedum alfredii is affected by continual clipping and phosphorus fertilization amendment.

    Science.gov (United States)

    Huang, Huagang; Li, Tingqiang; Gupta, D K; He, Zhenli; Yang, Xiao-E; Ni, Bingnan; Li, Mao

    2012-01-01

    Improving the efficacy of phytoextraction is critical for its successful application in metal contaminated soils. Mineral nutrition affects plant growth and metal absorption and subsequently the accumulation of heavy metal through hyper-accumulator plants. This study assessed the effects of di-hydrogen phosphates (KH2PO4, Ca(H2PO4)2, NaH2PO4 and NH4H2PO4) application at three levels (22, 88 and 352 mg P/kg soil) on Sedum alfredii growth and metal uptake by three consecutive harvests on aged and Zn/Cd combined contaminated paddy soil. The addition of phosphates (P) significantly increased the amount of Zn taken up by S. alfredii due to increased shoot Zn concentration and dry matter yield (DMY) (P phytoextraction of Zn and Cd was observed in KH2PO4 and NH4H2PO4 treatment at 352 mg P/kg soil. The amount of Zn removed by phytoextraction increased in the order of 1st clipping < 2nd clipping < 3rd clipping, and for Cd extraction the order was 2nd clipping < 1st clipping < 3rd clipping. These results indicate that the application of P fertilizers coupled with multiple cuttings can enhance the removal of Zn and Cd from contaminated soils by S. alfredii, thus shortening the time needed for accomplishing remediation goals.

  7. Surgical clipping is still a good choice for the treatment of paraclinoid aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2016-04-01

    Full Text Available ABSTRACT Paraclinoid aneurysms are lesions located adjacent to the clinoid and ophthalmic segments of the internal carotid artery. In recent years, flow diverter stents have been introduced as a better endovascular technique for treatment of these aneurysms. Method From 2009 to 2014, a total of 43 paraclinoid aneurysms in 43 patients were surgically clipped. We retrospectively reviewed the records of these patients to analyze clinical outcomes. Results Twenty-six aneurysms (60.5% were ophthalmic artery aneurysms, while 17 were superior hypophyseal artery aneurysms (39.5%. The extradural approach to the clinoid process was used to clip these aneurysms. One hundred percent of aneurysms were clipped (complete exclusion in 100% on follow-up angiography. The length of follow-up ranged from 1 to 60 months (mean, 29.82 months. Conclusion Surgical clipping continues to be a good option for the treatment of paraclinoid aneurysms.

  8. Worst-case residual clipping noise power model for bit loading in LACO-OFDM

    KAUST Repository

    Zhang, Zhenyu; Chaaban, Anas; Shen, Chao; Elgala, Hany; Ng, Tien Khee; Ooi, Boon S.; Alouini, Mohamed-Slim

    2018-01-01

    Layered ACO-OFDM enjoys better spectral efficiency than ACO-OFDM, but its performance is challenged by residual clipping noise (RCN). In this paper, the power of RCN of LACO-OFDM is analyzed and modeled. As RCN is data-dependent, the worst-case situation is considered. A worst-case indicator is defined for relating the power of RCN and the power of noise at the receiver, wherein a linear relation is shown to be a practical approximation. An LACO-OFDM bit-loading experiment is performed to examine the proposed RCN power model for data rates of 6 to 7 Gbps. The experiment's results show that accounting for RCN has two advantages. First, it leads to better bit loading and achieves up to 59% lower overall bit-error rate (BER) than when the RCN is ignored. Second, it balances the BER across layers, which is a desired property from a channel coding perspective.

  9. An Exploration of Gender Bias in Computer Clip Art.

    Science.gov (United States)

    Dyrud, Marilyn A.

    1997-01-01

    Examines over 14,000 clip art images for gender bias. Finds that only 4% of images depicted women and that those images present women in stereotypical roles, such as secretaries, nurses, teachers. Notes the irony that communication instructors expend much effort persuading students that gender-free prose is the new model--while visually still…

  10. Film clips and narrative text as subjective emotion elicitation techniques.

    Science.gov (United States)

    Zupan, Barbra; Babbage, Duncan R

    2017-01-01

    Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).

  11. Aspirin-triggered resolvin D1 down-regulates inflammatory responses and protects against endotoxin-induced acute kidney injury

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jiao [Center for Research on Environmental Disease, University of Kentucky, Lexington, KY 40536 (United States); Shetty, Sreerama [Center for Biomedical Research, University of Texas Health Science Center at Tyler, Tyler, TX 75708 (United States); Zhang, Ping [State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China); Gao, Rong; Hu, Yuxin [Center for Research on Environmental Disease, University of Kentucky, Lexington, KY 40536 (United States); Wang, Shuxia [Graduate Center for Nutritional Sciences, College of Medicine, University of Kentucky, Lexington, KY 40536 (United States); Li, Zhenyu [Division of Cardiovascular Medicine, University of Kentucky, Lexington, KY 40536 (United States); Fu, Jian, E-mail: jian.fu@uky.edu [Center for Research on Environmental Disease, University of Kentucky, Lexington, KY 40536 (United States); Graduate Center for Toxicology, University of Kentucky, Lexington, KY 40536 (United States)

    2014-06-01

    The presence of endotoxin in blood can lead to acute kidney injury (AKI) and septic shock. Resolvins, the endogenous lipid mediators derived from docosahexaenoic acid, have been reported to exhibit potent anti-inflammatory action. Using a mouse model of lipopolysaccharide (LPS)-induced AKI, we investigated the effects of aspirin-triggered resolvin D1 (AT-RvD1) on inflammatory kidney injury. Administration of AT-RvD1 1 h after LPS challenge protected the mice from kidney injury as indicated by the measurements of blood urea nitrogen, serum creatinine, and morphological alterations associated with tubular damage. The protective effects were evidenced by decreased neutrophil infiltration in the kidney indicating reduction in inflammation. AT-RvD1 treatment restored kidney cell junction protein claudin-4 expression, which was otherwise reduced after LPS challenge. AT-RvD1 treatment inhibited endotoxin-induced NF-κB activation and suppressed LPS-induced ICAM-1 and VCAM-1 expression in the kidney. Moreover, AT-RvD1 treatment markedly decreased LPS-induced IL-6 level in the kidney and blocked IL-6-mediated signaling including STAT3 and ERK phosphorylation. Our findings demonstrate that AT-RvD1 is a potent anti-inflammatory mediator in LPS-induced kidney injury, and AT-RvD1 has therapeutic potential against AKI during endotoxemia.

  12. Aspirin-triggered resolvin D1 down-regulates inflammatory responses and protects against endotoxin-induced acute kidney injury

    International Nuclear Information System (INIS)

    Chen, Jiao; Shetty, Sreerama; Zhang, Ping; Gao, Rong; Hu, Yuxin; Wang, Shuxia; Li, Zhenyu; Fu, Jian

    2014-01-01

    The presence of endotoxin in blood can lead to acute kidney injury (AKI) and septic shock. Resolvins, the endogenous lipid mediators derived from docosahexaenoic acid, have been reported to exhibit potent anti-inflammatory action. Using a mouse model of lipopolysaccharide (LPS)-induced AKI, we investigated the effects of aspirin-triggered resolvin D1 (AT-RvD1) on inflammatory kidney injury. Administration of AT-RvD1 1 h after LPS challenge protected the mice from kidney injury as indicated by the measurements of blood urea nitrogen, serum creatinine, and morphological alterations associated with tubular damage. The protective effects were evidenced by decreased neutrophil infiltration in the kidney indicating reduction in inflammation. AT-RvD1 treatment restored kidney cell junction protein claudin-4 expression, which was otherwise reduced after LPS challenge. AT-RvD1 treatment inhibited endotoxin-induced NF-κB activation and suppressed LPS-induced ICAM-1 and VCAM-1 expression in the kidney. Moreover, AT-RvD1 treatment markedly decreased LPS-induced IL-6 level in the kidney and blocked IL-6-mediated signaling including STAT3 and ERK phosphorylation. Our findings demonstrate that AT-RvD1 is a potent anti-inflammatory mediator in LPS-induced kidney injury, and AT-RvD1 has therapeutic potential against AKI during endotoxemia

  13. Current MitraClip experience, safety and feasibility in the Netherlands

    OpenAIRE

    Rahhab, Z.; Kortlandt, F.A.; Velu, J.F.; Schurer, R.A.J.; Delgado, V.; Tonino, P.; Boven, A.J. van; Branden, B.J.L. Van den; Kraaijeveld, A.O.; Voskuil, M.; Hoorntje, J.; Wely, M.H. van; Houwelingen, K. van; Bleeker, G.B.; Rensing, B.

    2017-01-01

    PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device succe...

  14. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    International Nuclear Information System (INIS)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan

    2017-01-01

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ≤2 cm) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy

  15. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan [Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of)

    2017-03-15

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip{sub p}, ≤2 cm) and 3 distal clips (clip{sub d}, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

  16. EFFECT OF CHRONIC ACE-INHIBITION ON THE DIAGNOSTIC-VALUE OF RENOGRAPHY FOR RENOVASCULAR HYPERTENSION - A PRELIMINARY-REPORT

    NARCIS (Netherlands)

    VISSCHER, CA; DEZEEUW, D; HUISMAN, RM

    1995-01-01

    We compared the effects of acute and chronic ACE inhibition (ACEi) on the I-123-hippurate in the stenotic kidney of two 2-kidney, 1-clip hypertensive dogs. In the period after clip implantation poststenotic renograms without ACEi of both dogs were normal. Acute ACEi always resulted in delayed

  17. Fibroblast Growth Factor 23 and Kidney Disease Progression in Autosomal Dominant Polycystic Kidney Disease.

    Science.gov (United States)

    Chonchol, Michel; Gitomer, Berenice; Isakova, Tamara; Cai, Xuan; Salusky, Isidro; Pereira, Renata; Abebe, Kaleab; Torres, Vicente; Steinman, Theodor I; Grantham, Jared J; Chapman, Arlene B; Schrier, Robert W; Wolf, Myles

    2017-09-07

    Increases in fibroblast growth factor 23 precede kidney function decline in autosomal dominant polycystic kidney disease; however, the role of fibroblast growth factor 23 in autosomal dominant polycystic kidney disease has not been well characterized. We measured intact fibroblast growth factor 23 levels in baseline serum samples from 1002 participants in the HALT-PKD Study A ( n =540; mean eGFR =91±17 ml/min per 1.73 m 2 ) and B ( n =462; mean eGFR =48±12 ml/min per 1.73 m 2 ). We used linear mixed and Cox proportional hazards models to test associations between fibroblast growth factor 23 and eGFR decline, percentage change in height-adjusted total kidney volume, and composite of time to 50% reduction in eGFR, onset of ESRD, or death. Median (interquartile range) intact fibroblast growth factor 23 was 44 (33-56) pg/ml in HALT-PKD Study A and 69 (50-93) pg/ml in Study B. In adjusted models, annualized eGFR decline was significantly faster in the upper fibroblast growth factor 23 quartile (Study A: quartile 4, -3.62; 95% confidence interval, -4.12 to -3.12 versus quartile 1, -2.51; 95% confidence interval, -2.71 to -2.30 ml/min per 1.73 m 2 ; P for trend kidney volume in adjusted models (quartile 4, 6.76; 95% confidence interval, 5.57 to 7.96 versus quartile 1, 6.04; 95% confidence interval, 5.55 to 6.54; P for trend =0.03). In Study B, compared with the lowest quartile, the highest fibroblast growth factor 23 quartile was associated with elevated risk for the composite outcome (hazard ratio, 3.11; 95% confidence interval, 1.84 to 5.25). Addition of fibroblast growth factor 23 to a model of annualized decline in eGFR≥3.0 ml/min per 1.73 m 2 did not improve risk prediction. Higher serum fibroblast growth factor 23 concentration was associated with kidney function decline, height-adjusted total kidney volume percentage increase, and death in patients with autosomal dominant polycystic kidney disease. However, fibroblast growth factor 23 did not substantially

  18. Human Urine-Derived Renal Progenitors for Personalized Modeling of Genetic Kidney Disorders.

    Science.gov (United States)

    Lazzeri, Elena; Ronconi, Elisa; Angelotti, Maria Lucia; Peired, Anna; Mazzinghi, Benedetta; Becherucci, Francesca; Conti, Sara; Sansavini, Giulia; Sisti, Alessandro; Ravaglia, Fiammetta; Lombardi, Duccio; Provenzano, Aldesia; Manonelles, Anna; Cruzado, Josep M; Giglio, Sabrina; Roperto, Rosa Maria; Materassi, Marco; Lasagni, Laura; Romagnani, Paola

    2015-08-01

    The critical role of genetic and epigenetic factors in the pathogenesis of kidney disorders is gradually becoming clear, and the need for disease models that recapitulate human kidney disorders in a personalized manner is paramount. In this study, we describe a method to select and amplify renal progenitor cultures from the urine of patients with kidney disorders. Urine-derived human renal progenitors exhibited phenotype and functional properties identical to those purified from kidney tissue, including the capacity to differentiate into tubular cells and podocytes, as demonstrated by confocal microscopy, Western blot analysis of podocyte-specific proteins, and scanning electron microscopy. Lineage tracing studies performed with conditional transgenic mice, in which podocytes are irreversibly tagged upon tamoxifen treatment (NPHS2.iCreER;mT/mG), that were subjected to doxorubicin nephropathy demonstrated that renal progenitors are the only urinary cell population that can be amplified in long-term culture. To validate the use of these cells for personalized modeling of kidney disorders, renal progenitors were obtained from (1) the urine of children with nephrotic syndrome and carrying potentially pathogenic mutations in genes encoding for podocyte proteins and (2) the urine of children without genetic alterations, as validated by next-generation sequencing. Renal progenitors obtained from patients carrying pathogenic mutations generated podocytes that exhibited an abnormal cytoskeleton structure and functional abnormalities compared with those obtained from patients with proteinuria but without genetic mutations. The results of this study demonstrate that urine-derived patient-specific renal progenitor cultures may be an innovative research tool for modeling of genetic kidney disorders. Copyright © 2015 by the American Society of Nephrology.

  19. Functional outcome of microsurgical clipping compared to endovascular coiling.

    Science.gov (United States)

    Premananda, R M; Ramesh, N; Hillol, K P

    2012-12-01

    Endovascular coiling has been used increasingly as an alternative to neurosurgical clipping for treating subarachnoid hemorrhage secondary to aneurysm rupture. In a retrospective cohort review on the treatment methods of aneurysm rupture in Hospital Kuala Lumpur over the period of five years (2005-2009) a total of 268 patients were treated. These patients were broadly categorized into two groups based on their treatment mode for ruptured aneurysms. Statistical analysis was determined using Chi- Square tests to study these associations. In our study, 67.5% of patients presented with Good World Federation of Neurosurgical Societies (WFNS) grade (WFNS1-2) while 32.5% patients presented with Poor WFNS prior to intervention. In our outcome, it was noted that 60.4% had good functional outcome (mRS grade 0-2) as compared to 39.6% patients who had poor mRS(modified rankin scale) outcome (mRS 3-6). In the good WFNS group, 76% of patients in clipping group had a good mRS outcome while, 86.5% patients in coiling group had good mRS outcome (p=0.114). In poor WFNS presentation, it was noted that in 77.3% patients in clipping group, had poor mRS outcome. Similarly with poor WFNS presentation, 83.3% of patient in coiling group had poor outcome. (p=1.00). Hence when we control the WFNS group, there was no significant association between treatment group (clipping and coiling) and mRS outcome at 6 months. The outcome of patient is determined by initial clinical presentation (WFNS grade) and influenced by requirement of Extraventricular drain (EVD) in presence of hydrocephalus, CSF infection and pneumonia. Therefore the decision regarding treatment option needs to be individualized based on the presentation of the patient.

  20. Time-course effects of aerobic exercise training on cardiovascular and renal parameters in 2K1C renovascular hypertensive rats

    Directory of Open Access Journals (Sweden)

    R.C.A. Maia

    2015-01-01

    Full Text Available Exercise training (Ex has been recommended for its beneficial effects in hypertensive states. The present study evaluated the time-course effects of Ex without workload on mean arterial pressure (MAP, reflex bradycardia, cardiac and renal histology, and oxidative stress in two-kidney, one-clip (2K1C hypertensive rats. Male Fischer rats (10 weeks old; 150–180 g underwent surgery (2K1C or SHAM and were subsequently divided into a sedentary (SED group and Ex group (swimming 1 h/day, 5 days/week for 2, 4, 6, 8, or 10 weeks. Until week 4, Ex decreased MAP, increased reflex bradycardia, prevented concentric hypertrophy, reduced collagen deposition in the myocardium and kidneys, decreased the level of thiobarbituric acid-reactive substances (TBARS in the left ventricle, and increased the catalase (CAT activity in the left ventricle and both kidneys. From week 6 to week 10, however, MAP and reflex bradycardia in 2K1C Ex rats became similar to those in 2K1C SED rats. Ex effectively reduced heart rate and prevented collagen deposition in the heart and both kidneys up to week 10, and restored the level of TBARS in the left ventricle and clipped kidney and the CAT activity in both kidneys until week 8. Ex without workload for 10 weeks in 2K1C rats provided distinct beneficial effects. The early effects of Ex on cardiovascular function included reversing MAP and reflex bradycardia. The later effects of Ex included preventing structural alterations in the heart and kidney by decreasing oxidative stress and reducing injuries in these organs during hypertension.

  1. Endogenous angiotensin II modulates nNOS expression in renovascular hypertension

    Directory of Open Access Journals (Sweden)

    T.M.C. Pereira

    2009-07-01

    Full Text Available Nitric oxide (NO influences renal blood flow mainly as a result of neuronal nitric oxide synthase (nNOS. Nevertheless, it is unclear how nNOS expression is modulated by endogenous angiotensin II, an inhibitor of NO function. We tested the hypothesis that the angiotensin II AT1 receptor and oxidative stress mediated by NADPH oxidase contribute to the modulation of renal nNOS expression in two-kidney, one-clip (2K1C hypertensive rats. Experiments were performed on male Wistar rats (150 to 170 g body weight divided into 2K1C (N = 19 and sham-operated (N = 19 groups. nNOS expression in kidneys of 2K1C hypertensive rats (N = 9 was compared by Western blotting to that of 2K1C rats treated with low doses of the AT1 antagonist losartan (10 mg·kg-1·day-1; N = 5 or the superoxide scavenger tempol (0.2 mmol·kg-1·day-1; N = 5, which still remain hypertensive. After 28 days, nNOS expression was significantly increased by 1.7-fold in the clipped kidneys of 2K1C rats and by 3-fold in the non-clipped kidneys of 2K1C rats compared with sham rats, but was normalized by losartan. With tempol treatment, nNOS expression increased 2-fold in the clipped kidneys and 1.4-fold in the non-clipped kidneys compared with sham rats. The changes in nNOS expression were not followed by changes in the enzyme activity, as measured indirectly by the cGMP method. In conclusion, AT1 receptors and oxidative stress seem to be primary stimuli for increased nNOS expression, but this up-regulation does not result in higher enzyme activity.

  2. A calibration method for proposed XRF measurements of arsenic and selenium in nail clippings

    International Nuclear Information System (INIS)

    Gherase, Mihai R; Fleming, David E B

    2011-01-01

    A calibration method for proposed x-ray fluorescence (XRF) measurements of arsenic and selenium in nail clippings is demonstrated. Phantom nail clippings were produced from a whole nail phantom (0.7 mm thickness, 25 x 25 mm 2 area) and contained equal concentrations of arsenic and selenium ranging from 0 to 20 μg g -1 in increments of 5 μg g -1 . The phantom nail clippings were then grouped in samples of five different masses: 20, 40, 60, 80 and 100 mg for each concentration. Experimental x-ray spectra were acquired for each of the sample masses using a portable x-ray tube and a detector unit. Calibration lines (XRF signal in a number of counts versus stoichiometric elemental concentration) were produced for each of the two elements. A semi-empirical relationship between the mass of the nail phantoms (m) and the slope of the calibration line (s) was determined separately for arsenic and selenium. Using this calibration method, one can estimate elemental concentrations and their uncertainties from the XRF spectra of human nail clippings. (note)

  3. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    Wadd, I.H.; Haroon, A.; Ansari, S.

    2015-01-01

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  4. Kidney injury molecule-1 and microalbuminuria levels in Zambian ...

    African Journals Online (AJOL)

    Kidney injury molecule-1 and microalbuminuria levels in Zambian population: biomarkers of kidney injury. Mildred Zulu, Trevor Kaile, Timothy Kantenga, Chisanga Chileshe, Panji Nkhoma, Musalula Sinkala ...

  5. Adding run history to CLIPS

    Science.gov (United States)

    Tuttle, Sharon M.; Eick, Christoph F.

    1991-01-01

    To debug a C Language Integrated Production System (CLIPS) program, certain 'historical' information about a run is needed. It would be convenient for system builders to have the capability to request such information. We will discuss how historical Rete networks can be used for answering questions that help a system builder detect the cause of an error in a CLIPS program. Moreover, the cost of maintaining a historical Rete network is compared with that for a classical Rete network. We will demonstrate that the cost for assertions is only slightly higher for a historical Rete network. The cost for handling retraction could be significantly higher; however, we will show that by using special data structures that rely on hashing, it is also possible to implement retractions efficiently.

  6. Kidney deformation and intraprocedural registration: a study of elements of image-guided kidney surgery.

    Science.gov (United States)

    Altamar, Hernan O; Ong, Rowena E; Glisson, Courtenay L; Viprakasit, Davis P; Miga, Michael I; Herrell, Stanley Duke; Galloway, Robert L

    2011-03-01

    Central to any image-guided surgical procedure is the alignment of image and physical coordinate spaces, or registration. We explored the task of registration in the kidney through in vivo and ex vivo porcine animal models and a human study of minimally invasive kidney surgery. A set of (n = 6) ex vivo porcine kidney models was utilized to study the effect of perfusion and loss of turgor caused by incision. Computed tomography (CT) and laser range scanner localizations of the porcine kidneys were performed before and after renal vessel clamping and after capsular incision. The da Vinci robotic surgery system was used for kidney surface acquisition and registration during robot-assisted laparoscopic partial nephrectomy. The surgeon acquired the physical surface data points with a tracked robotic instrument. These data points were aligned to preoperative CT for surface-based registrations. In addition, two biomechanical elastic computer models (isotropic and anisotropic) were constructed to simulate deformations in one of the kidneys to assess predictive capabilities. The mean displacement at the surface fiducials (glass beads) in six porcine kidneys was 4.4 ± 2.1 mm (range 3.4-6.7 mm), with a maximum displacement range of 6.1 to 11.2 mm. Surface-based registrations using the da Vinci robotic instrument in robot-assisted laparoscopic partial nephrectomy yielded mean and standard deviation closest point distances of 1.4 and 1.1 mm. With respect to computer model predictive capability, the target registration error was on average 6.7 mm without using the model and 3.2 mm with using the model. The maximum target error reduced from 11.4 to 6.2 mm. The anisotropic biomechanical model yielded better performance but was not statistically better. An initial point-based alignment followed by an iterative closest point registration is a feasible method of registering preoperative image (CT) space to intraoperative physical (robot) space. Although rigid registration provides

  7. Worst-case residual clipping noise power model for bit loading in LACO-OFDM

    KAUST Repository

    Zhang, Zhenyu

    2018-03-19

    Layered ACO-OFDM enjoys better spectral efficiency than ACO-OFDM, but its performance is challenged by residual clipping noise (RCN). In this paper, the power of RCN of LACO-OFDM is analyzed and modeled. As RCN is data-dependent, the worst-case situation is considered. A worst-case indicator is defined for relating the power of RCN and the power of noise at the receiver, wherein a linear relation is shown to be a practical approximation. An LACO-OFDM bit-loading experiment is performed to examine the proposed RCN power model for data rates of 6 to 7 Gbps. The experiment\\'s results show that accounting for RCN has two advantages. First, it leads to better bit loading and achieves up to 59% lower overall bit-error rate (BER) than when the RCN is ignored. Second, it balances the BER across layers, which is a desired property from a channel coding perspective.

  8. A CLIPS expert system for clinical flow cytometry data analysis

    Science.gov (United States)

    Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.

    1990-01-01

    An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.

  9. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    Science.gov (United States)

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  10. CLIPS based decision support system for water distribution networks

    Directory of Open Access Journals (Sweden)

    K. Sandeep

    2011-10-01

    Full Text Available The difficulty in knowledge representation of a water distribution network (WDN problem has contributed to the limited use of artificial intelligence (AI based expert systems (ES in the management of these networks. This paper presents a design of a Decision Support System (DSS that facilitates "on-demand'' knowledge generation by utilizing results of simulation runs of a suitably calibrated and validated hydraulic model of an existing aged WDN corresponding to emergent or even hypothetical but likely scenarios. The DSS augments the capability of a conventional expert system by integrating together the hydraulic modelling features with heuristics based knowledge of experts under a common, rules based, expert shell named CLIPS (C Language Integrated Production System. In contrast to previous ES, the knowledge base of the DSS has been designed to be dynamic by superimposing CLIPS on Structured Query Language (SQL. The proposed ES has an inbuilt calibration module that enables calibration of an existing (aged WDN for the unknown, and unobservable, Hazen-Williams C-values. In addition, the daily run and simulation modules of the proposed ES further enable the CLIPS inference engine to evaluate the network performance for any emergent or suggested test scenarios. An additional feature of the proposed design is that the DSS integrates computational platforms such as MATLAB, open source Geographical Information System (GIS, and a relational database management system (RDBMS working under the umbrella of the Microsoft Visual Studio based common user interface. The paper also discusses implementation of the proposed framework on a case study and clearly demonstrates the utility of the application as an able aide for effective management of the study network.

  11. Molecular clips based on propanediurea : synthesis and physical properties

    NARCIS (Netherlands)

    Jansen, Robertus Johannes

    2002-01-01

    This thesis describes the synthesis and physical properties of a series of molecular clips derived from the concave molecule propanediurea. These molecular clips are cavity-containing receptors that can bind a variety of aromatic guests. This binding is a result of hydrogen bonding and pi-pi

  12. A spatially-averaged mathematical model of kidney branching morphogenesis

    KAUST Repository

    Zubkov, V.S.

    2015-08-01

    © 2015 Published by Elsevier Ltd. Kidney development is initiated by the outgrowth of an epithelial ureteric bud into a population of mesenchymal cells. Reciprocal morphogenetic responses between these two populations generate a highly branched epithelial ureteric tree with the mesenchyme differentiating into nephrons, the functional units of the kidney. While we understand some of the mechanisms involved, current knowledge fails to explain the variability of organ sizes and nephron endowment in mice and humans. Here we present a spatially-averaged mathematical model of kidney morphogenesis in which the growth of the two key populations is described by a system of time-dependant ordinary differential equations. We assume that branching is symmetric and is invoked when the number of epithelial cells per tip reaches a threshold value. This process continues until the number of mesenchymal cells falls below a critical value that triggers cessation of branching. The mathematical model and its predictions are validated against experimentally quantified C57Bl6 mouse embryonic kidneys. Numerical simulations are performed to determine how the final number of branches changes as key system parameters are varied (such as the growth rate of tip cells, mesenchyme cells, or component cell population exit rate). Our results predict that the developing kidney responds differently to loss of cap and tip cells. They also indicate that the final number of kidney branches is less sensitive to changes in the growth rate of the ureteric tip cells than to changes in the growth rate of the mesenchymal cells. By inference, increasing the growth rate of mesenchymal cells should maximise branch number. Our model also provides a framework for predicting the branching outcome when ureteric tip or mesenchyme cells change behaviour in response to different genetic or environmental developmental stresses.

  13. A spatially-averaged mathematical model of kidney branching morphogenesis

    KAUST Repository

    Zubkov, V.S.; Combes, A.N.; Short, K.M.; Lefevre, J.; Hamilton, N.A.; Smyth, I.M.; Little, M.H.; Byrne, H.M.

    2015-01-01

    © 2015 Published by Elsevier Ltd. Kidney development is initiated by the outgrowth of an epithelial ureteric bud into a population of mesenchymal cells. Reciprocal morphogenetic responses between these two populations generate a highly branched epithelial ureteric tree with the mesenchyme differentiating into nephrons, the functional units of the kidney. While we understand some of the mechanisms involved, current knowledge fails to explain the variability of organ sizes and nephron endowment in mice and humans. Here we present a spatially-averaged mathematical model of kidney morphogenesis in which the growth of the two key populations is described by a system of time-dependant ordinary differential equations. We assume that branching is symmetric and is invoked when the number of epithelial cells per tip reaches a threshold value. This process continues until the number of mesenchymal cells falls below a critical value that triggers cessation of branching. The mathematical model and its predictions are validated against experimentally quantified C57Bl6 mouse embryonic kidneys. Numerical simulations are performed to determine how the final number of branches changes as key system parameters are varied (such as the growth rate of tip cells, mesenchyme cells, or component cell population exit rate). Our results predict that the developing kidney responds differently to loss of cap and tip cells. They also indicate that the final number of kidney branches is less sensitive to changes in the growth rate of the ureteric tip cells than to changes in the growth rate of the mesenchymal cells. By inference, increasing the growth rate of mesenchymal cells should maximise branch number. Our model also provides a framework for predicting the branching outcome when ureteric tip or mesenchyme cells change behaviour in response to different genetic or environmental developmental stresses.

  14. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-05-01

    Recently, orthogonal frequency-division multiplexing (OFDM) has been adopted for high-speed wireless communications due to its robustness against multipath fading. However, one of the main fundamental drawbacks of OFDM systems is the high peak-to-average-power ratio (PAPR). Several techniques have been proposed for PAPR reduction. Most of these techniques require transmitter-based (pre-compensated) processing. On the other hand, receiver-based alternatives would save the power and reduce the transmitter complexity. By keeping this in mind, a possible approach is to limit the amplitude of the OFDM signal to a predetermined threshold and equivalently a sparse clipping signal is added. Then, estimating this clipping signal at the receiver to recover the original signal. In this work, we propose a Bayesian receiver-based low-complexity clipping signal recovery method for PAPR reduction. The method is able to i) effectively reduce the PAPR via simple clipping scheme at the transmitter side, ii) use Bayesian recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance), and at the same time iv is energy efficient due to its low complexity. Specifically, the proposed recovery technique is implemented in data-aided based. The data-aided method collects clipping information by measuring reliable 
data subcarriers, thus makes full use of spectrum for data transmission without the need for tone reservation. The study is extended further to discuss how to improve the recovery of the clipping signal utilizing some features of practical OFDM systems i.e., the oversampling and the presence of multiple receivers. Simulation results demonstrate the superiority of the proposed technique over other recovery algorithms. The overall objective is to show that the receiver-based Bayesian technique is highly

  15. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi

    2016-09-02

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have previously reported histone H3 specific proteolytic clipping and a protein inhibitor in chicken liver. However, the sites of clipping are still not known very well. In this study, we attempt to identify clipping sites in histone H3 and to determine the mechanism of inhibition by stefin B protein, a cysteine protease inhibitor. By employing site-directed mutagenesis and in vitro biochemical assays, we have identified three distinct clipping sites in recombinant human histone H3 and its variants (H3.1, H3.3, and H3t). However, post-translationally modified histones isolated from chicken liver and Saccharomyces cerevisiae wild-type cells showed different clipping patterns. Clipping of histone H3 N-terminal tail at three sites occurs in a sequential manner. We have further observed that clipping sites are regulated by the structure of the N-terminal tail as well as the globular domain of histone H3. We also have identified the QVVAG region of stefin B protein to be very crucial for inhibition of the protease activity. Altogether, our comprehensive biochemical studies have revealed three distinct clipping sites in histone H3 and their regulation by the structure of histone H3, histone modifications marks, and stefin B.

  16. Understanding and Applying Psychology through Use of News Clippings.

    Science.gov (United States)

    Rider, Elizabeth A.

    1992-01-01

    Discusses a student project for psychology courses in which students collect newspaper clippings that illustrate psychological concepts. Explains that the students record the source and write a brief description of the clipping, explaining how it relates to a psychological concept or theory. Includes results of student evaluations of the…

  17. Sympathetic block by metal clips may be a reversible operation

    DEFF Research Database (Denmark)

    Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa

    2014-01-01

    , but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. METHODS: Thoracoscopic clipping of the sympathetic trunk was performed in adult...... the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery...... suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know...

  18. Developing better mouse models to study cisplatin-induced kidney injury.

    Science.gov (United States)

    Sharp, Cierra N; Siskind, Leah J

    2017-10-01

    Cisplatin is a potent chemotherapeutic used for the treatment of many types of cancer. However, its dose-limiting side effect is nephrotoxicity leading to acute kidney injury (AKI). Patients who develop AKI have an increased risk of mortality and are more likely to develop chronic kidney disease (CKD). Unfortunately, there are no therapeutic interventions for the treatment of AKI. It has been suggested that the lack of therapies is due in part to the fact that the established mouse model used to study cisplatin-induced AKI does not recapitulate the cisplatin dosing regimen patients receive. In recent years, work has been done to develop more clinically relevant models of cisplatin-induced kidney injury, with much work focusing on incorporation of multiple low doses of cisplatin administered over a period of weeks. These models can be used to recapitulate the development of CKD after AKI and, by doing so, increase the likelihood of identifying novel therapeutic targets for the treatment of cisplatin-induced kidney injury. Copyright © 2017 the American Physiological Society.

  19. Effect of GLP-1 on the expression of NADPH oxidase subunits in the kidney of type 1 diabetic rats

    Directory of Open Access Journals (Sweden)

    Jin-jin LIU

    2013-09-01

    Full Text Available Objective To observe the effect of exenatide, a glucagon-like peptide-1 (GLP-1 receptor agonist, on the expression of NADPH oxidase subunits NOX4 and p22phox and connective tissue growth factor (CTGF in the kidney of streptozotocin (STZ-induced type 1 diabetic rats, and explore the protective effects and mechanisms of exenatide on the kidney of diabetic rats. Methods Thirty male Sprague-Dawley (SD rats were divided into control group (group A, n=7 and diabetic model group (n=23. Type 1 diabetic model was reproduced by intraperitoneal injection of streptozotocin. It was successful in 19 rats. Diabetic rats were randomly divided into diabetic control group (group B, n=10 and diabetic with treatment of exenatide group (group C, n=9. Rats in group C were injected subcutaneously with exenatide in dose of 5μg/kg twice daily. Rats in group A and B were given equivalent volume of normal saline by subcutaneous injection. All rats were sacrificed after eight weeks. The mRNA expression of renal p22phox and NOX4 were detected by real-time fluorescence quantitative PCR. The protein expression of CTGF was detected by immunohistochemical staining. Results The levels of blood glucose, lipids, creatinine, and urea nitrogen, the albumin excretion rate, kidney index, the mRNA expressions of renal NOX4 and p22phox, and the protein expression of renal CTGF were significantly increased in group B compared with that in group A (P0.05. Conclusion Exenatide can decrease the expressions of renal NOX4, p22phox and CTGF, decline the index of urinary protein, and alleviate the kidney hypertrophy in type 1 diabetic rats, implying that exenatide exerted a protective effect on the kidney.

  20. The influence of clipping frequency on reserve carbohydrates and ...

    African Journals Online (AJOL)

    Increasing the frequency of clipping over a 12 week period resulted in decreasing root and stubble weight at the end of the 12 week period. During the regrowth period, following the clipping treatment, the aerial dry matter production was found to increase with the more lenient treatments. Keywords: weights|dry ...

  1. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    Science.gov (United States)

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there

  2. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.

    2012-07-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  3. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.; Al-Naffouri, Tareq Y.

    2012-01-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  4. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    Science.gov (United States)

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  5. The contribution of CLIP2 haploinsufficiency to the clinical manifestations of the Williams-Beuren syndrome.

    Science.gov (United States)

    Vandeweyer, Geert; Van der Aa, Nathalie; Reyniers, Edwin; Kooy, R Frank

    2012-06-08

    Williams-Beuren syndrome is a rare contiguous gene syndrome, characterized by intellectual disability, facial dysmorphisms, connective-tissue abnormalities, cardiac defects, structural brain abnormalities, and transient infantile hypercalcemia. Genes lying telomeric to RFC2, including CLIP2, GTF2I and GTF2IRD1, are currently thought to be the most likely major contributors to the typical Williams syndrome cognitive profile, characterized by a better-than-expected auditory rote-memory ability, a relative sparing of language capabilities, and a severe visual-spatial constructive impairment. Atypical deletions in the region have helped to establish genotype-phenotype correlations. So far, however, hardly any deletions affecting only a single gene in the disease region have been described. We present here two healthy siblings with a pure, hemizygous deletion of CLIP2. A putative role in the cognitive and behavioral abnormalities seen in Williams-Beuren patients has been suggested for this gene on the basis of observations in a knock-out mouse model. The presented siblings did not show any of the clinical features associated with the syndrome. Cognitive testing showed an average IQ for both and no indication of the Williams syndrome cognitive profile. This shows that CLIP2 haploinsufficiency by itself does not lead to the physical or cognitive characteristics of the Williams-Beuren syndrome, nor does it lead to the Williams syndrome cognitive profile. Although contribution of CLIP2 to the phenotype cannot be excluded when it is deleted in combination with other genes, our results support the hypothesis that GTF2IRD1 and GTF2I are the main genes causing the cognitive defects associated with Williams-Beuren syndrome. Copyright © 2012 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  6. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-01-01

    recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance

  7. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  8. Equation-Method for correcting clipping errors in OFDM signals.

    Science.gov (United States)

    Bibi, Nargis; Kleerekoper, Anthony; Muhammad, Nazeer; Cheetham, Barry

    2016-01-01

    Orthogonal frequency division multiplexing (OFDM) is the digital modulation technique used by 4G and many other wireless communication systems. OFDM signals have significant amplitude fluctuations resulting in high peak to average power ratios which can make an OFDM transmitter susceptible to non-linear distortion produced by its high power amplifiers (HPA). A simple and popular solution to this problem is to clip the peaks before an OFDM signal is applied to the HPA but this causes in-band distortion and introduces bit-errors at the receiver. In this paper we discuss a novel technique, which we call the Equation-Method, for correcting these errors. The Equation-Method uses the Fast Fourier Transform to create a set of simultaneous equations which, when solved, return the amplitudes of the peaks before they were clipped. We show analytically and through simulations that this method can, correct all clipping errors over a wide range of clipping thresholds. We show that numerical instability can be avoided and new techniques are needed to enable the receiver to differentiate between correctly and incorrectly received frequency-domain constellation symbols.

  9. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  10. Surgical clips for position verification and correction of non-rigid breast tissue in simultaneously integrated boost (SIB) treatments

    International Nuclear Information System (INIS)

    Penninkhof, Joan; Quint, Sandra; Boer, Hans de; Mens, Jan Willem; Heijmen, Ben; Dirkx, Maarten

    2009-01-01

    Background and purpose: The aim of this study is to investigate whether surgical clips in the lumpectomy cavity are representative for position verification of both the tumour bed and the whole breast in simultaneously integrated boost (SIB) treatments. Materials and methods: For a group of 30 patients treated with a SIB technique, kV and MV planar images were acquired throughout the course of the fractionated treatment. The 3D set-up error for the tumour bed was derived by matching the surgical clips (3-8 per patient) in two almost orthogonal planar kV images. By projecting the 3D set-up error derived from the planar kV images to the (u, v)-plane of the tangential beams, the correlation with the 2D set-up error for the whole breast, derived from the MV EPID images, was determined. The stability of relative clip positions during the fractionated treatment was investigated. In addition, for a subgroup of 15 patients, the impact of breathing was determined from fluoroscopic movies acquired at the linac. Results: The clip configurations were stable over the course of radiotherapy, showing an inter-fraction variation (1 SD) of 0.5 mm on average. Between the start and the end of the treatment, the mean distance between the clips and their center of mass was reduced by 0.9 mm. A decrease larger than 2 mm was observed in eight patients (17 clips). The top-top excursion of the clips due to breathing was generally less than 2.5 mm in all directions. The population averages of the difference (±1 SD) between kV and MV matches in the (u, v)-plane were 0.2 ± 1.8 mm and 0.9 ± 1.5 mm, respectively. In 30% of the patients, time trends larger than 3 mm were present over the course of the treatment in either or in both kV and MV match results. Application of the NAL protocol based on the clips reduced the population mean systematic error to less than 2 mm in all directions, both for the tumour bed and the whole breast. Due to the observed time trends, these systematic errors can

  11. Murine nephrotoxic nephritis as a model of chronic kidney disease

    DEFF Research Database (Denmark)

    Ougaard, M. K.E.; Kvist, P. H.; Jensen, H. E.

    2018-01-01

    Using the nonaccelerated murine nephrotoxic nephritis (NTN) as a model of chronic kidney disease (CKD) could provide an easily inducible model that enables a rapid test of treatments. Originally, the NTN model was developed as an acute model of glomerulonephritis, but in this study we evaluate...... progressive mesangial expansion and significant renal fibrosis within three weeks suggesting CKD development. CD1 and C57BL/6 females showed a similar disease progression, but female mice seemed more susceptible to NTS compared to male mice. The presence of albuminuria, GFR decline, mesangial expansion...

  12. Current opinion on clip placement after breast biopsy: A survey of practising radiologists in France and Quebec

    International Nuclear Information System (INIS)

    Thomassin-Naggara, I.; Jalaguier-Coudray, A.; Chopier, J.; Tardivon, A.; Trop, I.

    2013-01-01

    Aim: To investigate current practice regarding clip placement after breast biopsy. Materials and methods: In June 2011, an online survey instrument was designed using an Internet-based survey site ( (www.surveymonkey.com)) to assess practices and opinions of breast radiologists regarding clip placement after breast biopsy. Radiologists were asked to give personal practice data, describe their current practice regarding clip deployment under stereotactic, ultrasonographic, and magnetic resonance imaging (MRI) guidance, and describe what steps are taken to ensure quality control with regards to clip deployment. Results: The response rate was 29.9% in France (131 respondents) and 46.7% in Quebec (50 respondents). The great majority of respondents used breast markers in their practice (92.1% in France and 96% in Quebec). In both countries, most reported deploying a clip after percutaneous biopsy under stereotactic or MRI guidance. Regarding clip deployment under ultrasonography, 38% of Quebec radiologists systematically placed a marker after each biopsy, whereas 30% of French radiologists never placed a marker in this situation, mainly due to its cost. Finally, 56.4% of radiologists in France and 54% in Quebec considered that their practice regarding clip deployment after breast percutaneous biopsy had changed in the last 5 years. Conclusion: There continues to be variations in the use of biopsy clips after imaging-guided biopsies, particularly with regards to sonographic techniques. These variations are likely to decrease over time, with the standardization of relatively new investigation protocols

  13. Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

    International Nuclear Information System (INIS)

    Penninkhof, Joan; Quint, Sandra; Baaijens, Margreet; Heijmen, Ben; Dirkx, Maarten

    2012-01-01

    Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocol or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 ± 1.2 mm (mean ± 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips’ COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips’ COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.

  14. Acute outcomes after MitraClip therapy in highly aged patients: results from the German TRAnscatheter Mitral valve Interventions (TRAMI) Registry.

    Science.gov (United States)

    Schillinger, Wolfgang; Hünlich, Mark; Baldus, Stephan; Ouarrak, Taoufik; Boekstegers, Peter; Hink, Ulrich; Butter, Christian; Bekeredjian, Raffi; Plicht, Björn; Sievert, Horst; Schofer, Joachim; Senges, Jochen; Meinertz, Thomas; Hasenfuß, Gerd

    2013-05-20

    The influence of age on baseline demographics and outcomes of patients selected for MitraClip has not been previously investigated. Baseline demographics and acute outcomes in 1,064 patients from the German TRAMI registry were stratified by age (525 patients ≥76 years and 539 patients 50% (40.1% vs. 21.8%, p<0.0001) and degenerative mitral regurgitation (DMR, 35.3% vs. 25.6%, p<0.01). Age was the most frequent reason for non-surgical treatment in the elderly (69.4% vs. 36.1%, p<0.0001). The intrahospital MACCE (death, myocardial infarction, stroke) was low in both groups (3.5% vs. 3.4%, p=0.93) and the proportion of non-severe mitral regurgitation at discharge was similar (95.8% vs. 96.4%, p=0.73). A logistic regression model did not reveal any significant impact of age on acute efficacy and safety of MitraClip therapy. In both groups, the majority of patients were discharged home (81.8% vs. 86.2%, p=0.06). Elderly and younger patients have similar benefits from MitraClip therapy. Age was the most frequent cause for denying surgery in elderly patients.

  15. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  16. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    Science.gov (United States)

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, PElectrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  17. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification

    International Nuclear Information System (INIS)

    Thomas, Carys W.; Nichol, Alan M.; Park, Julie E.; Hui, Jason F.; Giddings, Alison A.; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac TM ). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT

  18. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification.

    Science.gov (United States)

    Thomas, Carys W; Nichol, Alan M; Park, Julie E; Hui, Jason F; Giddings, Alison A; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT.

  19. Increased susceptibility to structural acute kidney injury in a mouse model of presymptomatic cardiomyopathy.

    Science.gov (United States)

    Pleasant, LaTawnya; Ma, Qing; Devarajan, Mahima; Parameswaran, Priyanka; Drake, Keri; Siroky, Brian; Shay-Winkler, Kritton; Robbins, Jeffrey; Devarajan, Prasad

    2017-09-01

    The early events that signal renal dysfunction in presymptomatic heart failure are unclear. We tested the hypothesis that functional and mechanistic changes occur in the kidney that precede the development of symptomatic heart failure. We employed a transgenic mouse model with cardiomyocyte-specific overexpression of mutant α-B-crystallin that develops slowly progressive cardiomyopathy. Presymptomatic transgenic mice displayed an increase in serum creatinine (1.17 ± 0.34 vs. wild type 0.65 ± 0.16 mg/dl, P kidneys exhibited a twofold upregulation of the Ren1 gene, marked overexpression of renin protein in the tubules, and a worsened response to ischemia-reperfusion injury based on serum creatinine (2.77 ± 0.66 in transgenic mice vs. 2.01 ± 0.58 mg/dl in wild type, P kidney that occur in early presymptomatic heart failure, which increase the susceptibility to subsequent acute kidney injury. Copyright © 2017 the American Physiological Society.

  20. [Application of 3D soft print models of the kidney for treatment of patients with localized cancer of the kidney (a pilot study)].

    Science.gov (United States)

    Alyaev, Yu G; Sirota, E S; Bezrukov, E A; Fiev, D N; Bukatov, M D; Letunovskii, A V; Byadretdinov, I Sh

    2017-12-01

    To evaluate the possibility of using 3D-printing in the management of patients with localized kidney cancer. The study comprised five patients with localized kidney cancer who were treated at the Urology Clinic of the I.M. Sechenov First Moscow State Medical University from January 2016 to April 2017. Along with the standard examination, the patients underwent multispiral computed tomography (MSCT) to produce patient-specific 3D-printed models of the kidney tumors using 3D modeling and 3D printing. To evaluate the effectiveness of using 3D-printed models, two-stage preoperative planning was conducted, and five surgeons were surveyed using a four-question multiple choice questionnaire. At the first stage, the planning of operations was carried out based on MSCT findings. At the second stage, the surgeons were given patient-specific soft 3D models of the kidney with a tumor for preoperative training. After preoperative training, patients underwent laparoscopic resection of the kidney with a tumor. According to the survey results, each of the participating surgeons at least once changed surgical plan based on data obtained with 3D printed models of the kidney with the tumor. The implementation of preoperative training using 3D printed models of the kidney turned out to be effective. All patients underwent laparoscopic surgery performed by a single surgeon with extensive experience in this type of surgery. The mean operative time was 187 minutes. All operations were performed with main renal artery occlusion. The men warm ischemia time was 19.5 minutes and the mean blood loss was 170 ml. There were no conversions to open surgery and organ-removing operations. There were no postoperative complications or deaths. All surgical margins were negative. Morphological examination showed that four patients had renal cell carcinoma one patient had the oncocytoma. The study demonstrated the promise of using 3D printing for preoperative planning and surgical performance due to a

  1. Como o clipping pode auxiliar o dermatologista How the Nail clipping helps the dermatologist

    Directory of Open Access Journals (Sweden)

    José Fillus Neto

    2009-04-01

    Full Text Available Alterações ungueais são queixas muito frequentes nos consultórios dermatológicos. Onicomicoses representam cerca de 50% das onicopatias, daí a importância de se estabelecer o diagnóstico correto antes de se iniciar o tratamento. Neste artigo, relataremos a utilidade de um exame que é de fácil execução pelo clínico, de baixo custo e sensível: esse exame consiste na análise histopatológica da queratina ungueal distal, atualmente já consagrado com o termo clipping.Onycodystrophies are common problems in dermatologic practice. About 50% of dystrophic nails have a fungal cause, so it is very important to establish a correct diagnosis before treatment. In this article we relate the usefulness of an easydoing exam, free from pain, cheap and sensible. This exam is the histopathology of the nail keratin or nail clipping.

  2. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  3. Deletion of Rac1GTPase in the Myeloid Lineage Protects against Inflammation-Mediated Kidney Injury in Mice.

    Directory of Open Access Journals (Sweden)

    Miki Nagase

    Full Text Available Macrophage-mediated inflammation has been implicated in various kidney diseases. We previously reported that Rac1, a Rho family small GTP-binding protein, was overactivated in several chronic kidney disease models, and that Rac1 inhibitors ameliorated renal injury, in part via inhibition of inflammation, but the detailed mechanisms have not been clarified. In the present study, we examined whether Rac1 in macrophages effects cytokine production and the inflammatory mechanisms contributing to kidney derangement. Myeloid-selective Rac1 flox control (M-Rac1 FC and knockout (M-Rac1 KO mice were generated using the cre-loxP system. Renal function under basal conditions did not differ between M-Rac1 FC and KO mice. Accordingly, lipopolysaccharide (LPS-evoked kidney injury model was created. LPS elevated blood urea nitrogen and serum creatinine, enhanced expressions of kidney injury biomarkers, Kim-1 and Ngal, and promoted tubular injury in M-Rac1 FC mice. By contrast, deletion of myeloid Rac1 almost completely prevented the LPS-mediated renal impairment. LPS triggered a marked induction of macrophage-derived inflammatory cytokines, IL-6 and TNFα, in M-Rac1 FC mice, which was accompanied by Rac1 activation, stimulation of reduced nicotinamide-adenine dinucleotide phosphate (NADPH oxidase, and reactive oxygen species overproduction. These changes were inhibited in M-Rac1 KO mice. LPS evoked F4/80-positive macrophages accumulation in the kidney, which was not affected by myeloid Rac1 deficiency. We further tested the role of Rac1 signaling in cytokine production using macrophage cell line, RAW264.7. Exposure to LPS increased IL-6 and TNFα mRNA expression. The LPS-driven cytokine induction was dose-dependently blocked by the Rac1 inhibitor EHT1864, NADPH oxidase inhibitor diphenyleneiodonium, and NF-κB inhibitor BAY11-7082. In conclusion, genetic ablation of Rac1 in the myeloid lineage protected against LPS-induced renal inflammation and injury, by

  4. Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.

    Science.gov (United States)

    Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas

    2018-04-01

    Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Kidneys at Higher Risk of Discard: Expanding the Role of Dual Kidney Transplantation

    Science.gov (United States)

    Tanriover, B.; Mohan, S.; Cohen, D. J.; Radhakrishnan, J.; Nickolas, T. L.; Stone, P. W.; Tsapepas, D. S.; Crew, R. J.; Dube, G. K.; Sandoval, P. R.; Samstein, B.; Dogan, E.; Gaston, R. S.; Tanriover, J. N.; Ratner, L. E.; Hardy, M. A.

    2014-01-01

    Half of the recovered expanded criteria donor (ECD) kidneys are discarded in the United States. A new kidney allocation system offers kidneys at higher risk of discard, Kidney Donor Profile Index (KDPI) >85%, to a wider geographic area to promote broader sharing and expedite utilization. Dual kidney transplantation (DKT) based on the KDPI is a potential option to streamline allocation of kidneys which otherwise would have been discarded. To assess the clinical utility of the KDPI in kidneys at higher risk of discard, we analyzed the OPTN/UNOS Registry that included the deceased donor kidneys recovered between 2002 and 2012. The primary outcomes were allograft survival, patient survival and discard rate based on different KDPI categories (90%). Kidneys with KDPI >90% were associated with increased odds of discard (OR = 1.99, 95% CI 1.74–2.29) compared to ones with KDPI 90% were associated with lower overall allograft failure (HR = 0.74, 95% CI 0.62–0.89) and better patient survival (HR = 0.79, 95% CI 0.64–0.98) compared to single ECD kidneys with KDPI >90%. Kidneys at higher risk of discard may be offered in the up-front allocation system as a DKT. Further modeling and simulation studies are required to determine a reasonable KDPI cutoff percentile. PMID:24472195

  6. Living donor risk model for predicting kidney allograft and patient survival in an emerging economy.

    Science.gov (United States)

    Zafar, Mirza Naqi; Wong, Germaine; Aziz, Tahir; Abbas, Khawar; Adibul Hasan Rizvi, S

    2018-03-01

    Living donor kidney is the main source of donor organs in low to middle income countries. We aimed to develop a living donor risk model that predicts graft and patient survival in an emerging economy. We used data from the Sindh Institute of Urology and Transplantation (SIUT) database (n = 2283 recipients and n = 2283 living kidney donors, transplanted between 1993 and 2009) and conducted Cox proportional hazard analyses to develop a composite score that predicts graft and patient survivals. Donor factors age, creatinine clearance, nephron dose (estimated by donor/recipient body weight ratio) and human leukocyte antigen (HLA) match were included in the living donor risk model. The adjusted hazard ratios (HRs) for graft failures among those who received a kidney with living donor scores (reference to donor score of zero) of 1, 2, 3 and 4 were 1.14 (95%CI: 0.94-1.39), 1.24 (95%CI:1.03-1.49), 1.25 (95%CI:1.03-1.51) and 1.36 (95%CI:1.08-1.72) (P-value for trend =0.05). Similar findings were observed for patient survival. Similar to findings in high income countries, our study suggests that donor characteristics such as age, nephron dose, creatinine clearance and HLA match are important factors that determine the long-term patient and graft survival in low income countries. However, other crucial but undefined factors may play a role in determining the overall risk of graft failure and mortality in living kidney donor transplant recipients. © 2016 Asian Pacific Society of Nephrology.

  7. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    International Nuclear Information System (INIS)

    Lee, H; Yoon, J; Lee, E; Cho, S; Park, K; Choi, W; Baek, J; Keum, K; Koom, W

    2015-01-01

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm

  8. Multichannel infinite clipping as a form of sampling of speech signals

    International Nuclear Information System (INIS)

    Guidarelli, G.

    1985-01-01

    A remarkable improvement of both intelligibility and naturalness of infinitely clipped speech can be achieved by means of a multichannel system in which the speech signal is splitted into several band-pass channels before the clipping and successively reconstructed by summing up the clipped outputs of each channel. A possible explanation of such an improvement is given, founded on the so-called zero-based representation of band limited signals where the zero-crossings sequence is considered as a set of samples of the signal

  9. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

    Science.gov (United States)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-12-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. • Post-clip MRI is useful for confirming adequate sampling of US-guided biopsy. • Post-clip MRI following US-guided biopsy revealed a 96.6 % technical success rate. • One technical failure case was a benign, 1.1-cm non-mass enhancement. • The technical success rate of US-guided biopsy for non-mass enhancements was 83.3 %.

  10. Delay line clipping in a scintillation camera system

    International Nuclear Information System (INIS)

    Hatch, K.F.

    1979-01-01

    The present invention provides a novel base line restoring circuit and a novel delay line clipping circuit in a scintillation camera system. Single and double delay line clipped signal waveforms are generated for increasing the operational frequency and fidelity of data detection of the camera system by base line distortion such as undershooting, overshooting, and capacitive build-up. The camera system includes a set of photomultiplier tubes and associated amplifiers which generate sequences of pulses. These pulses are pulse-height analyzed for detecting a scintillation having an energy level which falls within a predetermined energy range. Data pulses are combined to provide coordinates and energy of photopeak events. The amplifiers are biassed out of saturation over all ranges of pulse energy level and count rate. Single delay line clipping circuitry is provided for narrowing the pulse width of the decaying electrical data pulses which increase operating speed without the occurrence of data loss. (JTA)

  11. Reduction in podocyte SIRT1 accelerates kidney injury in aging mice.

    Science.gov (United States)

    Chuang, Peter Y; Cai, Weijing; Li, Xuezhu; Fang, Lu; Xu, Jin; Yacoub, Rabi; He, John Cijiang; Lee, Kyung

    2017-09-01

    Both the incidence and prevalence of chronic kidney disease are increasing in the elderly population. Although aging is known to induce kidney injury, the underlying molecular mechanisms remain unclear. Sirtuin 1 (Sirt1), a longevity gene, is known to protect kidney cell injury from various cellular stresses. In previous studies, we showed that the podocyte-specific loss of Sirt1 aggravates diabetic kidney injury. However, the role of Sirt1 in aging-induced podocyte injury is not known. Therefore, in this study we sought to determine the effects of podocyte-specific reduction of Sirt1 in age-induced kidney injury. We employed the inducible podocyte-specific Sirt1 knockdown mice that express shRNA against Sirt1 (Pod-Sirt1 RNAi ) and control mice that express shRNA for luciferase (Pod-Luci RNAi ). We found that reduction of podocyte Sirt1 led to aggravated aging-induced glomerulosclerosis and albuminuria. In addition, urinary level of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a marker of oxidative stress, was markedly increased in aged Pod-Sirt1 RNAi mice compared with aged Pod-Luci RNAi mice. Although podocyte-specific markers decreased in aged mice compared with the young controls, the decrease was further exacerbated in aged Pod-Sirt1 RNAi compared with Pod-Luci RNAi mice. Interestingly, expression of cellular senescence markers was significantly higher in the glomeruli of Pod-Sirt1 RNAi mice than Pod-Luci RNAi mice, suggesting that cellular senescence may contribute to podocyte loss in aging kidneys. Finally, we confirmed that Pod-Sirt1 RNAi glomeruli were associated with reduced activation of the transcription factors peroxisome proliferator-activated receptor (PPAR)-α coactivador-1 (PGC1α)/PPARγ, forkhead box O (FOXO)3, FOXO4, and p65 NF-κB, through SIRT1-mediated deacetylation. Together, our data suggest that SIRT1 may be a potential therapeutic target to treat patients with aging-related kidney disease.

  12. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2011-08-15

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  13. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    International Nuclear Information System (INIS)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho

    2011-01-01

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  14. Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions. Reduction of coil and clip artifacts from intracranial aneurysm therapy

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, Sebastian; Baltsavias, Gerasimos; Michels, Lars; Valavanis, Antonios [University of Zurich, Department of Neuroradiology, University Hospital Zurich, Zurich (Switzerland); Hinzpeter, Ricarda; Stocker, Daniel; Alkadhi, Hatem [University of Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Burkhardt, Jan-Karl; Regli, Luca [University of Zurich, Department of Neurosurgery, University Hospital Zurich, Zurich (Switzerland)

    2018-03-15

    To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils. Fourteen clips and six coils were scanned in a phantom model with DECT at 100 and 150SnkVp. Four datasets were reconstructed: non-corrected images (filtered-back projection), iterative MAR, VME from DECT at 120 keV, and combined iterative MAR + VME images. Artifact severity scores and visibility of simulated, contrast-filled, adjacent vessels were assessed qualitatively and quantitatively by two independent, blinded readers. Iterative MAR, VME, and combined iterative MAR + VME resulted in a significant reduction of qualitative (p < 0.001) and quantitative clip artifacts (p < 0.005) and improved the visibility of adjacent vessels (p < 0.05) compared to non-corrected images, with lowest artifact scores found in combined iterative MAR + VME images. Titanium clips demonstrated less artifacts than Phynox clips (p < 0.05), and artifact scores increased with clip size. Coil artifacts increased with coil size but were reducible when applying iterative MAR + VME compared to non-corrected images. However, no technique improved the severe artifacts from large, densely packed coils. Combining iterative MAR with VME allows for an improved metal artifact reduction from clips and smaller, loosely packed coils. Limited value was found for large and densely packed coils. (orig.)

  15. Molecular Recognition Involving Anthraquinone Derivatives and Molecular Clips

    Science.gov (United States)

    Alaparthi, Madhubabu

    In the past, we have demonstrated that 1,8-anthraquinone-18-crown-5 (1) and its heterocyclic derivatives act as luminescent hosts for a variety of cations of environmental and clinical concern. We report here a series of heteroatom-substituted macrocycles containing an anthraquinone moiety as a fluorescent signaling unit and a cyclic polyheteroether chain as the receptor. Sulfur, selenium, and tellurium derivatives of 1,8-anthraquinone-18-crown-5 (1) were synthesized by reacting sodium sulfide (Na2S), sodium selenide (Na2Se) and sodium telluride (Na2Te) with 1,8-bis(2-bromoethylethyleneoxy)anthracene - 9,10-dione in a 1:1 ratio (2,3, and 6). These sensors bind metal ions in a 1:1 ratio (7 and 8), and the optical properties of the new complexes were examined and the sulfur and selenium analogues show that selectivity for Pb(II) is markedly improved as compared to the oxygen analogue 1 which was competitive for Ca(II) ion. Selective reduction of 1 yields secondary alcohols where either one or both of the anthraquinone carbonyl groups has been reduced ( 15 and 9). A new mechanism for the fluorescence detection of metal cations in solution is introduced involving a unique keto-enol tautomerization. Reduction of 1 yields the doubly reduced secondary alcohol, 9. 9 acts as a chemodosimeter for Al(III) ion producing a strong blue emission due to the formation of the anthracene fluorophore, 10, via dehydration of the internal secondary alcohol in DMSO/aqueous solution. The enol form is not the most thermodynamically stable form under these conditions however, and slowly converts to the keto form 11.. Currently we are focusing on cucurbituril derivatives, also described as molecular clips due to their folded geometry used as molecular recognition hosts. We first investigated the synthesis and characterization of aromatic methoxy/catechol terminated cucurbituril units that act as hosts for small solvent molecules, such as CH2Cl2, CH3CN, DMF, and MeOH, through dual pi...H-C T

  16. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  17. The associations of Bmi-1 with progression of glomerular chronic kidney disease
.

    Science.gov (United States)

    Yang, Xiaoxia; Bai, Ming; Ning, Xiaoxuan; Ma, Feng; Liu, Limin; Liu, Ting; Liu, Minna; Wang, Hanmin; Sun, Shiren

    2018-02-01

    Our previous studies indicated that Bmi-1 plays an important role in hypoxia-induced tubular epithelial-mesenchymal transition and the development of kidney fibrosis in cellular and animal models. However, circulating Bmi-1 levels in human chronic kidney disease (CKD) and their relation to progression remains unknown. We conducted a post-hoc analysis of a prospective cohort study. The blood samples and clinical data of 230 patients with glomerular CKD and 67 healthy adults were prospectively collected between January 2010 and June 2012. Serum Bmi-1 was measured using enzyme-linked immunosorbent assay (ELISA). CKD patients had significantly higher serum Bmi-1 concentrations than the healthy controls (496.4 (363.1 - 675.4) pg/mL compared with 257.3 (235.4 - 303.8) pg/mL, p Bmi-1 level inversely correlated with the estimated glomerular filtration rate (eGFR) (r = -0.346, p Bmi-1 levels and serum creatinine, blood urea nitrogen, cystatin C concentration, and the severity of tubulointerstitial fibrosis (r = 0.248, p Bmi-1 level was associated with a shorter duration of renal survival. Cox multivariate analyses further demonstrated that serum Bmi-1 concentration was an independent prognostic factor for CKD patients (HR = 6.48, p Bmi-1 levels were associated with adverse kidney disease outcome, suggesting that Bmi-1 is a novel biomarker for glomerular CKD progression. More data from larger longitudinal studies are required to validate our findings.
.

  18. Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Nader, Michel N.; Foran, Kelly A.; Groskopf, Craig; Reno, Michael C.; Ware, Chris S.; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J.

    2017-01-01

    The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20 µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K_α, selenium K_α, arsenic K_β, selenium K_β, and bromine K_α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K_α peak only, ranged from 0.210±0.002 µg/g selenium under one condition of analysis to 0.777±0.009 µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3 min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. - Highlights: • Portable X-ray fluorescence was used to assess As and Se in nail clipping phantoms. • Calibration lines were consistent between two different conditions of data analysis. • This new XRF approach was sensitive and required only a single nail clipping.

  19. The Chronic Kidney Disease Model: A General Purpose Model of Disease Progression and Treatment

    Directory of Open Access Journals (Sweden)

    Patel Uptal D

    2011-06-01

    Full Text Available Abstract Background Chronic kidney disease (CKD is the focus of recent national policy efforts; however, decision makers must account for multiple therapeutic options, comorbidities and complications. The objective of the Chronic Kidney Disease model is to provide guidance to decision makers. We describe this model and give an example of how it can inform clinical and policy decisions. Methods Monte Carlo simulation of CKD natural history and treatment. Health states include myocardial infarction, stroke with and without disability, congestive heart failure, CKD stages 1-5, bone disease, dialysis, transplant and death. Each cycle is 1 month. Projections account for race, age, gender, diabetes, proteinuria, hypertension, cardiac disease, and CKD stage. Treatment strategies include hypertension control, diabetes control, use of HMG-CoA reductase inhibitors, use of angiotensin converting enzyme inhibitors, nephrology specialty care, CKD screening, and a combination of these. The model architecture is flexible permitting updates as new data become available. The primary outcome is quality adjusted life years (QALYs. Secondary outcomes include health state events and CKD progression rate. Results The model was validated for GFR change/year -3.0 ± 1.9 vs. -1.7 ± 3.4 (in the AASK trial, and annual myocardial infarction and mortality rates 3.6 ± 0.9% and 1.6 ± 0.5% vs. 4.4% and 1.6% in the Go study. To illustrate the model's utility we estimated lifetime impact of a hypothetical treatment for primary prevention of vascular disease. As vascular risk declined, QALY improved but risk of dialysis increased. At baseline, 20% and 60% reduction: QALYs = 17.6, 18.2, and 19.0 and dialysis = 7.7%, 8.1%, and 10.4%, respectively. Conclusions The CKD Model is a valid, general purpose model intended as a resource to inform clinical and policy decisions improving CKD care. Its value as a tool is illustrated in our example which projects a relationship between

  20. Disease modeling in genetic kidney diseases: zebrafish.

    Science.gov (United States)

    Schenk, Heiko; Müller-Deile, Janina; Kinast, Mark; Schiffer, Mario

    2017-07-01

    Growing numbers of translational genomics studies are based on the highly efficient and versatile zebrafish (Danio rerio) vertebrate model. The increasing types of zebrafish models have improved our understanding of inherited kidney diseases, since they not only display pathophysiological changes but also give us the opportunity to develop and test novel treatment options in a high-throughput manner. New paradigms in inherited kidney diseases have been developed on the basis of the distinct genome conservation of approximately 70 % between zebrafish and humans in terms of existing gene orthologs. Several options are available to determine the functional role of a specific gene or gene sets. Permanent genome editing can be induced via complete gene knockout by using the CRISPR/Cas-system, among others, or via transient modification by using various morpholino techniques. Cross-species rescues succeeding knockdown techniques are employed to determine the functional significance of a target gene or a specific mutation. This article summarizes the current techniques and discusses their perspectives.

  1. Automated information retrieval using CLIPS

    Science.gov (United States)

    Raines, Rodney Doyle, III; Beug, James Lewis

    1991-01-01

    Expert systems have considerable potential to assist computer users in managing the large volume of information available to them. One possible use of an expert system is to model the information retrieval interests of a human user and then make recommendations to the user as to articles of interest. At Cal Poly, a prototype expert system written in the C Language Integrated Production System (CLIPS) serves as an Automated Information Retrieval System (AIRS). AIRS monitors a user's reading preferences, develops a profile of the user, and then evaluates items returned from the information base. When prompted by the user, AIRS returns a list of items of interest to the user. In order to minimize the impact on system resources, AIRS is designed to run in the background during periods of light system use.

  2. Acute upregulation of COX-2 by renal artery stenosis

    DEFF Research Database (Denmark)

    Mann, Birgitte; Hartner, A; Jensen, B L

    2001-01-01

    This study aimed to characterize the influence of acute renal artery stenosis on cyclooxygenase-2 (COX-2) and renin expression in the juxtaglomerular apparatus. For this purpose, male Sprague-Dawley rats received a left renal artery clip, and COX-2 mRNA, COX-2 immunoreactivity, plasma renin...... activity, and renin mRNA levels were determined. COX-2 mRNA and COX-2 immunoreactivity in the macula densa region in the clipped kidneys increased as early as 6 h after clipping and reached a maximal expression 1-2 days after clipping. Although values for plasma renin activity were elevated markedly at all...... time points examined, remaining renin mRNA levels were unchanged after 6 h and then increased to reach a maximum value 1-2 days after clipping. In the contralateral intact kidney, renin mRNA and COX-2 immunoreactivity decreased to approximately 50% of their normal values. To investigate a possible...

  3. Structural changes in the human vas deferens after tantalum clip occlusion and conventional vasectomy.

    Science.gov (United States)

    Kothari, L K; Gupta, A S

    1978-02-01

    In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.

  4. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories

    Science.gov (United States)

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488

  5. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories.

    Directory of Open Access Journals (Sweden)

    Antonio Maffei

    Full Text Available The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.

  6. Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study

    Directory of Open Access Journals (Sweden)

    Schenk Martin

    2016-09-01

    Full Text Available The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces.

  7. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    Science.gov (United States)

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  8. Transient receptor potential vanilloid 1 (TRPV1), TRPV4, and the kidney

    DEFF Research Database (Denmark)

    Kassmann, M.; Harteneck, C.; Zhu, Z.

    2013-01-01

    Recent preclinical data indicate that activators of transient receptor potential channels of the vanilloid receptor subtype 1 (TRPV1) may improve the outcome of ischaemic acute kidney injury (AKI). The underlying mechanisms are unclear, but may involve TRPV1 channels in dorsal root ganglion neuro...... pharmacological TRPV modulators may be a successful strategy for better treatment of acute or chronic kidney failure.......-activated potassium channels and promote vasodilation. The TRPV receptors can also form heteromers that exhibit unique conductance and gating properties, further increasing their spatio-functional diversity. This review summarizes data on electrophysiological properties of TRPV1/4 and their modulation by endogenous...

  9. S. pombe CLASP needs dynein, not EB1 or CLIP170, to induce microtubule instability and slows polymerization rates at cell tips in a dynein-dependent manner

    Science.gov (United States)

    Grallert, Agnes; Beuter, Christoph; Craven, Rachel A.; Bagley, Steve; Wilks, Deepti; Fleig, Ursula; Hagan, Iain M.

    2006-01-01

    The Schizosaccharomyces pombe CLIP170-associated protein (CLASP) Peg1 was identified in a screen for mutants with spindle formation defects and a screen for molecules that antagonized EB1 function. The conditional peg1.1 mutant enabled us to identify key features of Peg1 function. First, Peg1 was required to form a spindle and astral microtubules, yet destabilized interphase microtubules. Second, Peg1 was required to slow the polymerization rate of interphase microtubules that establish end-on contact with the cortex at cell tips. Third, Peg1 antagonized the action of S. pombe CLIP170 (Tip1) and EB1 (Mal3). Fourth, although Peg1 resembled higher eukaryotic CLASPs by physically associating with both Mal3 and Tip1, neither Tip1 nor Mal3 was required for Peg1 to destabilize interphase microtubules or for it to associate with microtubules. Conversely, neither Mal3 nor Tip1 required Peg1 to associate with microtubules or cell tips. Consistently, while mal3.Δ and tip1.Δ disrupted linear growth, corrupting peg1 + did not. Fifth, peg1.1 phenotypes resembled those arising from deletion of the single heavy or both light chains of fission yeast dynein. Furthermore, all interphase phenotypes arising from peg1 + manipulation relied on dynein function. Thus, the impact of S. pombe CLASP on interphase microtubule behavior is more closely aligned to dynein than EB1 or CLIP170. PMID:16951255

  10. Inducing negative affect using film clips with general and eating disorder-related content.

    Science.gov (United States)

    Koushiou, Maria; Nicolaou, Kalia; Karekla, Maria

    2018-02-09

    The aim of the present study was to select appropriate film clips with a general vs. eating disorder (ED)-related content to induce negative affect. More specifically, the study examined the subjective emotional experience (valence, arousal, anxiety, induction of somatic symptoms, and ability to control reactions during film clips) of Greek-Cypriot university students (N = 79) in response to three types of film clips: general unpleasant, ED-specific unpleasant, and emotionally neutral. In addition, the study aimed to compare the emotional reactions to the aforementioned clips between two groups of participants differing on their risk for ED (high vs. low). Preliminary results indicate the clips with general content ("The Champ") and with ED-specific content ("Binge eating") that are most effective in inducing negative affect and differentiating between risk groups. These clips provide an effective method for emotion induction that can be used for assessing the emotional experience of individuals with ED symptoms, since their emotional experience is significantly implicated in the development and maintenance of their symptoms (Merwin, Clin Psychol Sci Pract 18(3):208-214, 2011).Level of evidence No level of evidence, Experimental Study.

  11. The use of shape memory compression anastomosis clips in cholecystojejunostomy in pigs – a preliminary study

    Directory of Open Access Journals (Sweden)

    Piotr Holak

    2015-01-01

    Full Text Available This paper reports on the use of compression anastomosis clips (CAC in cholecystoenterostomy in an animal model. Cholecystojejunostomy was performed in 6 pigs using implants made of nickel-titanium alloy in the form of elliptical springs with two-way shape memory. The applied procedure led to the achievement of tight anastomosis with a minimal number of complications and positive results of histopathological evaluations of the anastomotic site. The results of the study indicate that shape memory NiTi clips are a promising surgical tool for cholecystoenterostomy in cats and dogs.

  12. SOCIOLINGUISTIC IMPORT OF NAME-CLIPPING AMONG ...

    African Journals Online (AJOL)

    NGOZI

    2013-02-27

    Feb 27, 2013 ... experiences which, most of the times, encompass cultural and philosophical ... The art of name clipping goes way back in language history ... describes Akan names as “iconic representation of complete social variables that ...

  13. Understanding Thiel embalming in pig kidneys to develop a new circulation model.

    Directory of Open Access Journals (Sweden)

    Wouter Willaert

    Full Text Available The quality of tissue preservation in Thiel embalmed bodies varies. Research on the administered embalming volume and its vascular distribution may elucidate one of the mechanisms of tissue preservation and allow for new applications of Thiel embalming. Vascular embalming with (group 1, n = 15 or without (group 2, n = 20 contrast agent was initiated in pig kidneys. The distribution of Thiel embalming solution in group 1 was visualized using computed tomography. The kidneys in both groups were then immersed in concentrated salt solutions to reduce their weight and volume. Afterwards, to mimic a lifelike circulation in the vessels, group 2 underwent pump-driven reperfusion for 120 minutes with either paraffinum perliquidum or diluted polyethylene glycol. The circulation was imaged with computed tomography. All of the kidneys were adequately preserved. The embalming solution spread diffusely in the kidney, but fluid accumulation was present. Subsequent immersion in concentrated salt solutions reduced weight (P < 0.01 and volume (P < 0.01. Reperfusion for 120 minutes was established in group 2. Paraffinum perliquidum filled both major vessels and renal tissue, whereas diluted polyethylene glycol spread widely in the kidney. There were no increases in weight (P = 0.26 and volume (P = 0.79; and pressure further decreased (P = 0.032 after more than 60 minutes of reperfusion with paraffinum perliquidum, whereas there were increases in weight (P = 0.005, volume (P = 0.032 and pressure (P < 0.0001 after reperfusion with diluted polyethylene glycol. Arterial embalming of kidneys results in successful preservation due to complete parenchymatous spreading. More research is needed to determine whether other factors affect embalming quality. Dehydration is an effective method to regain the organs' initial status. Prolonged vascular reperfusion with paraffinum perliquidum can be established in this model without increases in weight, volume and pressure.

  14. The Role of Y-Box Binding Protein 1 in Kidney Injury: Friend or Foe?

    Science.gov (United States)

    Ke, Ben; Fan, Chuqiao; Tu, Weiping; Fang, Xiangdong

    2018-01-01

    Y-box-binding protein 1 (YB-1) is a multifunctional protein involved in various cellular processes via the transcriptional and translational regulation of target gene expression. YB-1 promotes acute or chronic kidney injury through multiple molecular pathways; however, accumulating evidence suggests that significantly increased YB-1 levels are of great importance in renoprotection. In addition, YB-1 may contribute to obesity-related kidney disease by promoting adipogenesis. Thus, the role of YB-1 in kidney injury is complicated, and no comprehensive review is currently available. In this review, we summarise recent progress in our understanding of the function of YB-1 in kidney injury and provide an overview of the dual role of YB-1 in kidney disease. Moreover, we propose that YB-1 is a potential therapeutic target to restrict kidney disease. © 2018 The Author(s). Published by S. Karger AG, Basel.

  15. Object oriented development of engineering software using CLIPS

    Science.gov (United States)

    Yoon, C. John

    1991-01-01

    Engineering applications involve numeric complexity and manipulations of a large amount of data. Traditionally, numeric computation has been the concern in developing an engineering software. As engineering application software became larger and more complex, management of resources such as data, rather than the numeric complexity, has become the major software design problem. Object oriented design and implementation methodologies can improve the reliability, flexibility, and maintainability of the resulting software; however, some tasks are better solved with the traditional procedural paradigm. The C Language Integrated Production System (CLIPS), with deffunction and defgeneric constructs, supports the procedural paradigm. The natural blending of object oriented and procedural paradigms has been cited as the reason for the popularity of the C++ language. The CLIPS Object Oriented Language's (COOL) object oriented features are more versatile than C++'s. A software design methodology based on object oriented and procedural approaches appropriate for engineering software, and to be implemented in CLIPS was outlined. A method for sensor placement for Space Station Freedom is being implemented in COOL as a sample problem.

  16. Optimizing assessment of sexual arousal in postmenopausal women using erotic film clips.

    Science.gov (United States)

    Ramos Alarcon, Lauren G; Dai, Jing; Collins, Karen; Perez, Mindy; Woodard, Terri; Diamond, Michael P

    2017-10-01

    This study sought to assess sexual arousal in a subgroup of women by identifying erotic film clips that would be most mentally appealing and physically arousing to postmenopausal women. By measuring levels of mental appeal and self-reported physical arousal using a bidirectional scale, we aimed to elucidate the clips that would best be utilized for sexual health research in the postmenopausal or over 50-year-old subpopulation. Our results showed that postmenopausal women did not rate clips with older versus younger actors differently (p>0.05). The mean mental and mean physical scores were significantly correlated for both premenopausal subject ratings (r=0.69, perotic film clips; this knowledge is relevant for design of future sexual function research. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Effect of hair coat clipping on some physiological changes of dairy bulls

    Directory of Open Access Journals (Sweden)

    Prasanpanich, S.

    2006-03-01

    Full Text Available Some physiological responses of 6 Friesian crossbred (87.5% bull yearling with 2.5 years old, averaging 235 kg. bodyweight were investigated under hot humid conditions. All animals were raised in a house (4 × 15 × 5; w × l × h meters, respectively with concrete floor and were assigned to the Pair Comparison Design according to their weight and age into 2 groups. Animals in group 1 were maintained with their natural hair coat while their counterparts in group 2 were coat clipped fortnightly through a 70-day experimental period. The results indicated that the clipped animals had a significantly (P<0.05 lower sweating rate than did the unclipped ones (102.7±15.48 and 48.3±15.48 g/m2/hour, respectively. However, there were no significant differences in rectal temperature, skin temperature and respiratory rate between the two groups of animals. Further study should be done to clarify the consequences of lower sweating rate in clipped animals under hot humid conditions.

  18. Evaluation of regenerative capacity after kidney ischemic/reperfustion injury using 99mTc-DMSA

    International Nuclear Information System (INIS)

    Kwak, W. J.; Kim, J. W.; Park, K. M.; Lee, S. W.; Ahn, B. C.; Lee, J. T.; Yoo, J. S.

    2007-01-01

    Acute renal failure can be caused by a reduced renal blood flow induced because of ischemic injury. The damaged kidney can be completely restored in structure and function. 99m Tc-DMSA binds to cortical tubules in kidney and its uptake has been suggested to indicate function of cortical mass. Herein, the generative capacity of kidney after bilateral or unilateral ischemia/reperfusion (I/R) injury was evaluated non-invasively by scintigraphic imaging. Three different animal models were used. One or both kidneys of mice were subjected ischemic for 30 min for unilateral or bilateral I/R model, respectively. In third model, one kidney was excised and the other kidney was subjected ischemic for 30 min to give nephrectomy model. At 1 hr, 1 d, 3 d, 1 w, 2 w, 3 w after reperfusion, 99m Tc-DMSA (27.7 MBq) was injected via tail vein. After 3 hr, the mice were scanned for 30 min with pinhole equipped gamma camera. The ratio of ROI counts of kidney to total counts was calculated. In unilateral I/R mouse, the 99m Tc-DMSA uptake of injured kidney was decreased continuously up to 3 w (13.9 to 7.7%), while uptake in normal kidney is slowly increased. In case of nephrectomy model, 99m Tc-DMSA uptake of injured kidney was rapidly restored within 1 w after I/R operation (8.5 to 30%). Bilateral model showed reduced 99m Tc-DMSA uptake at 1 d, but total uptake in both I/R kidney was also increase up to 30% after 1 w and the uptake was maintained up to 3 w. In unilateral model, the 99m Tc-DMSA uptake of injured kidney kept decreasing up to 3 w while normal kidney showed increased 99m Tc-DMSA uptake. The restoration of I/R kidney was not observed within 3 w. However, in case of animal models which have only I/R kidneys such as bilateral and nephrectomy models, the 99m Tc-DMSA uptake was restored within 1 w and the excised kidney size was also normal in contrast to much smaller I/R kidney of unilateral model

  19. Establishment of an easy Ic measurement method of HTS superconducting tapes using clipped voltage taps

    International Nuclear Information System (INIS)

    Shin, Hyung Seop; Nisay, Arman; Dedicatoria, Marlon; Sim, Ki Deok

    2014-01-01

    The critical current, I c of HTS superconducting tapes can be measured by transport or contactless method. Practically, the transport method using the four-probe method is the most common. In this study, a simple test procedure by clipping the voltage lead taps have been introduced instead of soldering which reduces time and effort and thereby achieving a much faster measurement of I c . When using a pair of iron clips, I c value decreased as compared with the measured one by standard method using soldered voltage taps and varies with the width of the clipped specimen part. However, when using a pure Cu clip, both by clipping and by soldering voltage taps give a comparable result and I c measured are equal and close to the samples specification. As a result, material to be used as voltage clip should be considered and should not influence the potential voltage between the leads during I c measurement. Furthermore, the simulation result of magnetic flux during I c measurement test showed that the decrease of I c observed in the experiment is due to the magnetic flux density, By produced at the clipped part of the sample by the operating current with iron clips attached to the sample.

  20. Integrating knowledge and control into hypermedia-based training environments: Experiments with HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.

    1990-01-01

    The issues of knowledge representation and control in hypermedia-based training environments are discussed. The main objective is to integrate the flexible presentation capability of hypermedia with a knowledge-based approach to lesson discourse management. The instructional goals and their associated concepts are represented in a knowledge representation structure called a 'concept network'. Its functional usages are many: it is used to control the navigation through a presentation space, generate tests for student evaluation, and model the student. This architecture was implemented in HyperCLIPS, a hybrid system that creates a bridge between HyperCard, a popular hypertext-like system used for building user interfaces to data bases and other applications, and CLIPS, a highly portable government-owned expert system shell.

  1. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Expression of tumor necrosis factor receptor-associated protein 1 and its clinical significance in kidney cancer.

    Science.gov (United States)

    Si, Tong; Yang, Guosheng; Qiu, Xiaofu; Luo, Youhua; Liu, Baichuan; Wang, Bingwei

    2015-01-01

    To investigate the expression and clinical significance of TRAP1 (tumor necrosis factor receptor-associated protein 1) in kidney cancer. TRAP1 expression was detected in kidney cancer and normal kidney tissues by qRT-PCR and immunohistochemistry (IHC), respectively. Then, the correlation of TRAP1 expression with clinicopathological characters and patients' prognosis was evaluated in kidney cancer. IHC results revealed that the high-expression rates of TRAP1 in kidney cancer tissues and normal kidney tissues were 51.3% (41/80), 23.3% (7/30), and the difference was statistically significant (P=0.01). Also, TRAP1 mRNA level in kidney cancer was found to be significantly greater compared with those in normal kidney by qRT-PCR. In addition, TRAP1 expression in kidney cancer significantly correlated with lymph node metastasis and clinical stage (Pkidney cancer and correlates with patients prognosis, which may be served as a potential marker for the diagnosis and treatment of kidney cancer.

  3. Dynamic computed tomography (CT) in the rat kidney and application to acute renal failure models

    International Nuclear Information System (INIS)

    Ishikawa, Isao; Saito, Tadashi; Ishii, Hirofumi; Bansho, Junichi; Koyama, Yukinori; Tobita, Akira

    1995-01-01

    Renal dynamic CT scanning is suitable for determining the excretion of contrast medium in the cortex and medulla of the kidney, which is valuable for understanding the pathogenesis of disease processes in various conditions. This form of scanning would be convenient for use, if a method of application to the rat kidney were available. Therefore, we developed a method of applying renal dynamic CT to rats and evaluated the cortical and medullary curves, e.g., the corticomedullary junction time which is correlated to creatinine clearance, in various rat models of acute renal failure. The rat was placed in a 10deg oblique position and a bilateral hilar slice was obtained before and 5, 10, 15, 20, 25, 30, 40, 50, 60, 80, 100, 120, 140, 160 and 180 sec after administering 0.5 ml of contrast medium using Somatom DR. The width of the slice was 4 mm and the scan time was 3 sec. The corticomedullary junction time in normal rats was 23.0±10.5 sec, the peak value of the cortical curve was 286.3±76.7 Hounsfield Unit (HU) and the peak value of the medullary curve was 390.1±66.2 HU. Corticomedullary junction time after exposure of the kidney was prolonged compared to that of the unexposed kidney. In rats with acute renal failure, the excretion pattern of contrast medium was similar in both the glycerol- and HgCl2-induced acute renal failure models. The peak values of the cortical curve were maintained three hours after a clamp was placed at the hilar region of the kidney for one hour, and the peak values of the medullary curve were maintained during the administration of 10μg/kg/min of angiotensin II. Dynamic CT curves in the acute renal failure models examined were slightly different from those in human acute renal failure. These results suggest that rats do not provide an ideal model for human acute renal failure. However, the application of dynamic CT to the rat kidney models was valuable for estimating the pathogenesis of various human kidney diseases. (author)

  4. The Use of Film Clips in a Viewing Time Task of Sexual Interests.

    Science.gov (United States)

    Lalumière, Martin L; Babchishin, Kelly M; Ebsworth, Megan

    2018-04-01

    Viewing time tasks using still pictures to assess age and gender sexual interests have been well validated and are commonly used. The use of film clips in a viewing time task would open up interesting possibilities for the study of sexual interest toward sexual targets or activities that are not easily captured in still pictures. We examined the validity of a viewing time task using film clips to assess sexual interest toward male and female targets, in a sample of 52 young adults. Film clips produced longer viewing times than still pictures. For both men and women, the indices derived from the film viewing time task were able to distinguish individuals who identified as homosexual (14 men, 8 women) from those who identified as heterosexual (15 men, 15 women), and provided comparable group differentiation as indices derived from a viewing time task using still pictures. Men's viewing times were more gender-specific than those of women. Viewing times to film clips were correlated with participants' ratings of sexual appeal of the same clips, and with viewing times to pictures. The results support the feasibility of a viewing time measure of sexual interest that utilizes film clips and, thus, expand the types of sexual interests that could be investigated (e.g., sadism, biastophilia).

  5. Anti-hypertensive effect of Gastrodia elata Bl leaf extract in rats

    African Journals Online (AJOL)

    Methods: The two-kidney one-clip (2K1C) Goldblatt model of renovascular hypertension was used in. Wistar rats. ... urea levels of the rats were measured by enzyme-linked immunosorbent assay (ELISA). Superoxide ... Hypertension is the most common risk factor for .... (BP-6 noninvasive Electro-Sphygmomanometer,.

  6. Hypoxia-inducible factor 1α regulates branching morphogenesis during kidney development.

    Science.gov (United States)

    Tsuji, Kenji; Kitamura, Shinji; Makino, Hirofumi

    2014-04-25

    The kidneys are exposed to hypoxic conditions during development. Hypoxia-inducible factor (HIF), an important mediator of the response to hypoxia, is believed to have an important role in development. However, the relationship between HIF and branching morphogenesis has not been elucidated clearly. In this study, we examined whether HIF regulates kidney development. We harvested kidneys from day 13 rat embryos (E13Ks) and cultured the organs under normoxic (20% O2/5% CO2) or hypoxic (5% O2/5% CO2) conditions. We evaluated the kidneys based on morphology and gene expression. E13Ks cultured under hypoxic conditions had significantly more ureteric bud (UB) branching than the E13Ks cultured under normoxic conditions. In addition, the mRNA levels of GDNF and GDNF receptor (GFR-α1), increased under hypoxic conditions in E13Ks. When we cultured E13Ks with the HIF-1α inhibitor digoxin or with siRNA targeting HIF-1α under hypoxic conditions, we did not observe increased UB branching. In addition, the expression of GDNF and GFR-α1 was inhibited under hypoxic conditions when the kidneys were treated with siRNA targeting HIF-1α. We also elucidated that hypoxia inhibited UB cell apoptosis and promoted the expression of FGF7 mRNA levels in metanephric mesenchymal (MM) cells in vitro. These findings suggest that hypoxic condition has important roles in inducing branching morphogenesis during kidney development. Hypoxia might mediate branching morphogenesis via not only GDNF/Ret but also FGF signaling pathway. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. [Gene transfer-induced human heme oxygenase-1 over-expression protects kidney from ischemia-reperfusion injury in rats].

    Science.gov (United States)

    Lü, Jin-xing; Yan, Chun-yin; Pu, Jin-xian; Hou, Jian-quan; Yuan, He-xing; Ping, Ji-gen

    2010-12-14

    To study the protection of gene transfer-induced human heme oxygenase-1 over-expression against renal ischemia reperfusion injury in rats. The model of kidney ischemia-reperfusion injury was established with Sprague-Dawley rats. In the therapy group (n=18), the left kidney was perfused and preserved with Ad-hHO-1 at 2.5×10(9) pfu/1.0 ml after flushed with 0-4°C HC-A organ storage solution via donor renal aorta. The rats in control groups were perfused with 0.9% saline solution (n=12) or the vector carrying no interest gene Ad-EGFP 2.5×10(9) pfu/1.0 ml (n=18) instead of Ad-hHO-1. BUN and Cr in serum were measured by slide chemical methods. The kidney samples of rats were harvested for assay of histology, immunohistochemistry and quantification of HO enzymatic activity. Apoptosis cells in the kidney were measured by TUNEL. Ad-hHO-1 via donor renal aorta could transfect renal cells of rats effectively, enzymatic activity of HO in treated group [(1.62±0.07) nmol×mg(-1)×min(-1)] is higher than in control groups treated with saline solution team [(1.27±0.07) nmol×mg(-1)×min(-1)] and vector EGFP team [(1.22±0.06) nmol×mg(-1)×min(-1)] (PhHO-1 expressed hHO-1 in kidneys at a high level. Corresponding to this, the level of BUN and Cr, as well as the number of apoptosis cells, were decreased, and the damage in histology by HE staining was ameliorated. Over-expression of human HO-1 can protect the kidney from ischemia/reperfusion injury in rats.

  8. The Development of a Machine Learning Inpatient Acute Kidney Injury Prediction Model.

    Science.gov (United States)

    Koyner, Jay L; Carey, Kyle A; Edelson, Dana P; Churpek, Matthew M

    2018-03-28

    To develop an acute kidney injury risk prediction model using electronic health record data for longitudinal use in hospitalized patients. Observational cohort study. Tertiary, urban, academic medical center from November 2008 to January 2016. All adult inpatients without pre-existing renal failure at admission, defined as first serum creatinine greater than or equal to 3.0 mg/dL, International Classification of Diseases, 9th Edition, code for chronic kidney disease stage 4 or higher or having received renal replacement therapy within 48 hours of first serum creatinine measurement. None. Demographics, vital signs, diagnostics, and interventions were used in a Gradient Boosting Machine algorithm to predict serum creatinine-based Kidney Disease Improving Global Outcomes stage 2 acute kidney injury, with 60% of the data used for derivation and 40% for validation. Area under the receiver operator characteristic curve (AUC) was calculated in the validation cohort, and subgroup analyses were conducted across admission serum creatinine, acute kidney injury severity, and hospital location. Among the 121,158 included patients, 17,482 (14.4%) developed any Kidney Disease Improving Global Outcomes acute kidney injury, with 4,251 (3.5%) developing stage 2. The AUC (95% CI) was 0.90 (0.90-0.90) for predicting stage 2 acute kidney injury within 24 hours and 0.87 (0.87-0.87) within 48 hours. The AUC was 0.96 (0.96-0.96) for receipt of renal replacement therapy (n = 821) in the next 48 hours. Accuracy was similar across hospital settings (ICU, wards, and emergency department) and admitting serum creatinine groupings. At a probability threshold of greater than or equal to 0.022, the algorithm had a sensitivity of 84% and a specificity of 85% for stage 2 acute kidney injury and predicted the development of stage 2 a median of 41 hours (interquartile range, 12-141 hr) prior to the development of stage 2 acute kidney injury. Readily available electronic health record data can be used

  9. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by

  10. Renovascular hypertension in spontaneous hypertensive rats: an experimental model of renal artery stenosis superimposed on essential hypertension.

    Science.gov (United States)

    Rosenthal, T; Bass, A; Grossman, E; Shani, M; Griffel, B; Adar, R

    1987-09-01

    Renovascular hypertension superimposed on essential hypertension, a condition encountered in the elderly, was studied. An experimental animal model consisting of a two-kidney one-clip Goldblatt preparation in the spontaneous hypertensive (SHR) rat, that would simulate this condition, was designed. A 0.25 mm silver clip was placed on the left renal artery of SHR male rats. The same procedure performed on WKY rats served as control. All experiments were performed on low, normal, and rich sodium diet. Systolic blood pressure (BP) was measured by tail-cuff method. Plasma renin concentration (PRC) was determined before and after clipping of the renal artery. Results were as follows: Mean systolic BP increased significantly in clipped rats fed with normal and rich sodium diets. SHR showed an increase from 144 +/- 3 (mean + s.e.m.) to 168 +/- 3 mmHg, and WKY rats showed an increase from 120 +/- 2 to 139 +/- 5 mmHg. There was a two- to threefold rise in PRC. A low-salt diet given prior to clipping prevented the appearance of renovascular hypertension despite a significant rise in PRC. We concluded that renal artery narrowing plays a significant role in the rise of BP in the basically essential type of hypertension.

  11. A comparison of two endoscopic closures: over-the-scope clip (OTSC) versus KING closure (endoloop plus clips) in a randomized long-term experimental study

    Czech Academy of Sciences Publication Activity Database

    Doležel, R.; Ryska, O.; Kollár, M.; Juhásová, Jana; Kalvach, J.; Ryska, M.; Martínek, J.

    2016-01-01

    Roč. 30, č. 11 (2016), s. 4910-4916 ISSN 0930-2794 R&D Projects: GA MZd(CZ) NT13634; GA MŠk ED2.1.00/03.0124 Institutional support: RVO:67985904 Keywords : NOTES * endoscopic closure * KING closure * over-the-scope clip Subject RIV: FJ - Surgery incl. Transplants Impact factor: 3.747, year: 2016

  12. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-01

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc)2·nH2O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc)2·nH2O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals ( 5 to 15 nm) with high specific surface area of 88 m2/g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H2O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc)2·nH2O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc)2·nH2O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc)2·nH2O and EG has been proposed.

  13. 76 FR 44575 - Paper Clips From the People's Republic of China: Continuation of the Antidumping Duty Order

    Science.gov (United States)

    2011-07-26

    ..., butterfly clips, binder clips, or other paper fasteners that are not made wholly of wire of base metal and... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely...

  14. Using Short Movie and Television Clips in the Economics Principles Class

    Science.gov (United States)

    Sexton, Robert L.

    2006-01-01

    The author describes a teaching method that uses powerful contemporary media, movie and television clips, to demonstrate the enormous breadth and depth of economic concepts. Many different movie and television clips can be used to show the power of economic analysis. The author describes the scenes and the economic concepts within those scenes for…

  15. Portable inference engine: An extended CLIPS for real-time production systems

    Science.gov (United States)

    Le, Thach; Homeier, Peter

    1988-01-01

    The present C-Language Integrated Production System (CLIPS) architecture has not been optimized to deal with the constraints of real-time production systems. Matching in CLIPS is based on the Rete Net algorithm, whose assumption of working memory stability might fail to be satisfied in a system subject to real-time dataflow. Further, the CLIPS forward-chaining control mechanism with a predefined conflict resultion strategy may not effectively focus the system's attention on situation-dependent current priorties, or appropriately address different kinds of knowledge which might appear in a given application. Portable Inference Engine (PIE) is a production system architecture based on CLIPS which attempts to create a more general tool while addressing the problems of real-time expert systems. Features of the PIE design include a modular knowledge base, a modified Rete Net algorithm, a bi-directional control strategy, and multiple user-defined conflict resolution strategies. Problems associated with real-time applications are analyzed and an explanation is given for how the PIE architecture addresses these problems.

  16. Environmental exposure to arsenic and chromium in children is associated with kidney injury molecule-1

    International Nuclear Information System (INIS)

    Cárdenas-González, M.; Osorio-Yáñez, C.; Gaspar-Ramírez, O.; Pavković, M.; Ochoa-Martínez, A.; López-Ventura, D.

    2016-01-01

    Environmental hazards from natural or anthropological sources are widespread, especially in the north-central region of Mexico. Children represent a susceptible population due to their unique routes of exposure and special vulnerabilities. In this study we evaluated the association of exposure to environmental kidney toxicants with kidney injury biomarkers in children living in San Luis Potosi (SLP), Mexico. A cross-sectional study was conducted with 83 children (5–12 years of age) residents of Villa de Reyes, SLP. Exposure to arsenic, cadmium, chromium, fluoride and lead was assessed in urine, blood and drinking water samples. Almost all tap and well water samples had levels of arsenic (81.5%) and fluoride (100%) above the permissible levels recommended by the World Health Organization. Mean urine arsenic (45.6 ppb) and chromium (61.7 ppb) were higher than the biological exposure index, a reference value in occupational settings. Using multivariate adjusted models, we found a dose-dependent association between kidney injury molecule-1 (KIM-1) across chromium exposure tertiles [(T1: reference, T2: 467 pg/mL; T3: 615 pg/mL) (p-trend=0.001)]. Chromium upper tertile was also associated with higher urinary miR-200c (500 copies/μl) and miR-423 (189 copies/μL). Arsenic upper tertile was also associated with higher urinary KIM-1 (372 pg/mL). Other kidney injury/functional biomarkers such as serum creatinine, glomerular filtration rate, albuminuria, neutrophil gelatinase-associated lipocalin and miR-21 did not show any association with arsenic, chromium or any of the other toxicants evaluated. We conclude that KIM-1 might serve as a sensitive biomarker to screen children for kidney damage induced by environmental toxic agents. - Highlights: • Children living in Mexico had exceedingly high arsenic and chromium exposure. • Arsenic and chromium exposure was significantly associated with urinary KIM-1. • KIM-1 might serve as a sensitive biomarker to evaluate kidney

  17. Environmental exposure to arsenic and chromium in children is associated with kidney injury molecule-1

    Energy Technology Data Exchange (ETDEWEB)

    Cárdenas-González, M. [Laboratory of Systems Pharmacology, Harvard Program in Therapeutic Sciences, Harvard Medical School, Boston, MA (United States); Osorio-Yáñez, C. [Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, MA (United States); Gaspar-Ramírez, O. [Centro de Investigación y Asistencia en Tecnología y Diseño del Estado de Jalisco, Unidad Noreste (CIATEJ), Nuevo Leon (Mexico); Pavković, M. [Laboratory of Systems Pharmacology, Harvard Program in Therapeutic Sciences, Harvard Medical School, Boston, MA (United States); Renal Division, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Ochoa-Martínez, A. [Laboratorio de Toxicología Molecular, Centro de Investigación Aplicada en Ambiente y Salud (CIAAS), Coordinación para la Innovación y Aplicación de la Ciencia y la Tecnología (CIACYT), Universidad Autónoma de San Luis Potosí, San Luis Potosí (Mexico); López-Ventura, D. [Departamento de Toxicología, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV), México City (Mexico); and others

    2016-10-15

    Environmental hazards from natural or anthropological sources are widespread, especially in the north-central region of Mexico. Children represent a susceptible population due to their unique routes of exposure and special vulnerabilities. In this study we evaluated the association of exposure to environmental kidney toxicants with kidney injury biomarkers in children living in San Luis Potosi (SLP), Mexico. A cross-sectional study was conducted with 83 children (5–12 years of age) residents of Villa de Reyes, SLP. Exposure to arsenic, cadmium, chromium, fluoride and lead was assessed in urine, blood and drinking water samples. Almost all tap and well water samples had levels of arsenic (81.5%) and fluoride (100%) above the permissible levels recommended by the World Health Organization. Mean urine arsenic (45.6 ppb) and chromium (61.7 ppb) were higher than the biological exposure index, a reference value in occupational settings. Using multivariate adjusted models, we found a dose-dependent association between kidney injury molecule-1 (KIM-1) across chromium exposure tertiles [(T1: reference, T2: 467 pg/mL; T3: 615 pg/mL) (p-trend=0.001)]. Chromium upper tertile was also associated with higher urinary miR-200c (500 copies/μl) and miR-423 (189 copies/μL). Arsenic upper tertile was also associated with higher urinary KIM-1 (372 pg/mL). Other kidney injury/functional biomarkers such as serum creatinine, glomerular filtration rate, albuminuria, neutrophil gelatinase-associated lipocalin and miR-21 did not show any association with arsenic, chromium or any of the other toxicants evaluated. We conclude that KIM-1 might serve as a sensitive biomarker to screen children for kidney damage induced by environmental toxic agents. - Highlights: • Children living in Mexico had exceedingly high arsenic and chromium exposure. • Arsenic and chromium exposure was significantly associated with urinary KIM-1. • KIM-1 might serve as a sensitive biomarker to evaluate kidney

  18. Should We Formulate an Incentivized Model Facilitating Kidney Donation from Living Donors? A Focus on Turkey's Current System.

    Science.gov (United States)

    Avci, Ercan

    2018-04-23

    Kidney transplantation is a lifesaving medical treatment. However, very high demand for kidneys with low kidney donation causes a black market that exploits patients' desperation and donors' vulnerability. The current kidney donation programs fail to produce promising results to avoid illegal and unethical kidney trafficking and commercialism. Even though the primary goal of kidney donation is to increase the number of deceased organ donations, in some countries, like Turkey, due to religious or cultural concerns, it is impossible to supply adequate deceased kidney donations. In this view, the aim of this paper is to examine kidney trafficking in the scope of Turkey's current organ donation system and propose a new model, named the Incentivized Kidney Donation Model (IKDM), to increase kidney donation from living donors. The model encompasses the following benefits offered to kidney donors; lifetime health insurance, exemptions from copayments/contribution shares, priority when receiving an organ, priority when finding a job, income tax exemptions for salaried employees, and free or discounted public utilities. This normative model has the potential to promote donors' altruistic acts as well as the solidarity and loyalty among members of a society without violating ethical values and internationally accepted principles. © 2018 John Wiley & Sons Ltd.

  19. Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips

    International Nuclear Information System (INIS)

    Goenner, F.; Heid, O.; Remonda, L.; Schroth, G.; Loevblad, K.O.; Guzman, R.; Barth, A.

    2002-01-01

    We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of intracranial aneurysm clips and to display adjacent cerebral arteries. In five patients (aged 8-72 years) treated with Elgiloy or Phynox aneurysm clips we prospectively performed a conventional (TE 6.0 ms) and a new ultrashort TE (TE 2.4 ms) 3D TOF MRA. We compared the diameter of the clip-induced susceptibility artefact and the detectability of flow in adjacent vessels. The mean artefact diameter was 22.3±6.4 mm (range 14-38 mm) with the ultrashort TE and 27.7±6.4 mm (range 19-45 mm) with the conventional MRA (P<0.0001). This corresponded to a diameter reduction of 19.5±9.2%. More parts of adjacent vessels were detected, but with less intense flow signal. The aneurysm dome and neck remained within the area of signal loss and were therefore not displayed. Ultrashort TE MRA is a noninvasive and fast method for improving detection of vessels adjacent to clipped intracranial aneurysms, by reducing clip-induced susceptibility artefact. The method cannot, however, be used to show remnants of the aneurysm neck or sac as a result of imperfect clipping. (orig.)

  20. Clinical features and nail clippings in 52 children with psoriasis.

    Science.gov (United States)

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  1. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process.

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-09

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc) 2 ·nH 2 O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc) 2 ·nH 2 O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals (~ 5 to 15 nm) with high specific surface area of 88 m 2 /g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H 2 O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc) 2 ·nH 2 O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc) 2 ·nH 2 O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc) 2 ·nH 2 O and EG has been proposed.

  2. What Animal Models Have Taught Us About the Safety and Efficacy of Bisphosphonates in Chronic Kidney Disease.

    Science.gov (United States)

    Allen, Matthew R; Aref, Mohammad W

    2017-06-01

    Bisphosphonates (BPs) have long been the gold-standard anti-remodeling treatment for numerous metabolic bone diseases. Since these drugs are excreted unmetabolized through the kidney, they are not recommended for individuals with compromised kidney function due to concerns of kidney and bone toxicity. The goal of this paper is to summarize the preclinical BP work in models of kidney disease with particular focus on the bone, kidney, and vasculature. Summative data exists showing positive effects on bone and vascular calcifications with minimal evidence for bone or kidney toxicity in animal models. Preclinical data suggest it may be worthwhile to take a step back and reconsider the use of bisphosphonates to lessen skeletal/vascular complications associated with compromised kidney function.

  3. Magnolia Extract (BL153 Ameliorates Kidney Damage in a High Fat Diet-Induced Obesity Mouse Model

    Directory of Open Access Journals (Sweden)

    Wenpeng Cui

    2013-01-01

    Full Text Available Accumulating evidence demonstrated that obesity is a risk factor for renal structural and functional changes, leading to the end-stage renal disease which imposes a heavy economic burden on the community. However, no effective therapeutic method for obesity-associated kidney disease is available. In the present study, we explored the therapeutic potential of a magnolia extract (BL153 for treating obesity-associated kidney damage in a high fat diet- (HFD- induced mouse model. The results showed that inflammation markers (tumor necrosis factor-α and plasminogen activator inhibitor-1 and oxidative stress markers (3-nitrotyrosine and 4-hydroxy-2-nonenal were all significantly increased in the kidney of HFD-fed mice compared to mice fed with a low fat diet (LFD. Additionally, proteinuria and renal structure changes in HFD-fed mice were much more severe than that in LFD-fed mice. However, all these alterations were attenuated by BL153 treatment, accompanied by upregulation of peroxisome proliferator-activated receptor-γ coactivator-1α (PGC-1α and hexokinase II (HK II expression in the kidney. The present study indicates that BL153 administration may be a novel approach for renoprotection in obese individuals by antiinflammation and anti-oxidative stress most likely via upregulation of PGC-1α and HK II signal in the kidney.

  4. The role of high mobility group box 1(HMGB1)in the pathogenesis of kidney diseases

    Institute of Scientific and Technical Information of China (English)

    Qingjie Chen; Xiaofeng Guan; Xiaocong Zuo; Jianglin Wang; Wenjun Yin

    2016-01-01

    High mobility group box 1(HMGB1) is a nuclear protein that can bind to DNA and act as a co-factor for gene transcription. When released into extracellular fluid, it plays a proinflammatory role by acting as a damage-associated molecular pattern molecule(DAMP)(also known as an alarmin) to initiate innate immune responses by activating multiple cell surface receptors such as the receptor for advanced glycation end-products(RAGE) and toll-like receptors(TLRs), TLR2, TLR4 or TLR9. This proinflammatory role is now considered to be important in the pathogenesis of a wide range of kidney diseases whether they result from hemodynamic changes, renal tubular epithelial cell apoptosis, kidney tissue fibrosis or inflammation. This review summarizes our current understanding of the role of HMGB1 in kidney diseases and how the HMGB1-mediated signaling pathway may constitute a new strategy for the treatment of kidney diseases.

  5. Human kidney anion exchanger 1 interacts with adaptor-related protein complex 1 μ1A (AP-1 mu1A)

    International Nuclear Information System (INIS)

    Sawasdee, Nunghathai; Junking, Mutita; Ngaojanlar, Piengpaga; Sukomon, Nattakan; Ungsupravate, Duangporn; Limjindaporn, Thawornchai; Akkarapatumwong, Varaporn; Noisakran, Sansanee; Yenchitsomanus, Pa-thai

    2010-01-01

    Research highlights: → Trafficking defect of kAE1 is a cause of dRTA but trafficking pathway of kAE1 has not been clearly described. → Adaptor-related protein complex 1 μ1A (AP-1 mu1A) was firstly reported to interact with kAE1. → The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. → AP-1 mu1A knockdown showed a marked reduction of kAE1 on the cell membrane and its accumulation in endoplasmic reticulum. → AP-1 mu1A has a critical role in kAE1 trafficking to the plasma membrane. -- Abstract: Kidney anion exchanger 1 (kAE1) mediates chloride (Cl - ) and bicarbonate (HCO 3 - ) exchange at the basolateral membrane of kidney α-intercalated cells. Impaired trafficking of kAE1 leads to defect of the Cl - /HCO 3 - exchange at the basolateral membrane and failure of proton (H + ) secretion at the apical membrane, causing a kidney disease - distal renal tubular acidosis (dRTA). To gain a better insight into kAE1 trafficking, we searched for proteins physically interacting with the C-terminal region of kAE1 (Ct-kAE1), which contains motifs crucial for intracellular trafficking, by a yeast two-hybrid (Y2H) system. An adaptor-related protein complex 1 μ1A (AP-1 mu1A) subunit was found to interact with Ct-kAE1. The interaction between either Ct-kAE1 or full-length kAE1 and AP-1 mu1A were confirmed in human embryonic kidney (HEK) 293T by co-immunoprecipitation, affinity co-purification, co-localization, yellow fluorescent protein (YFP)-based protein fragment complementation assay (PCA) and GST pull-down assay. The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. Interestingly, suppression of endogenous AP-1 mu1A in HEK 293T by small interfering RNA (siRNA) decreased membrane localization of kAE1 and increased its intracellular accumulation, suggesting for the first time that AP-1 mu1A is involved in the kAE1 trafficking of kidney α-intercalated cells.

  6. Human kidney anion exchanger 1 interacts with adaptor-related protein complex 1 {mu}1A (AP-1 mu1A)

    Energy Technology Data Exchange (ETDEWEB)

    Sawasdee, Nunghathai; Junking, Mutita [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Ngaojanlar, Piengpaga [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Department of Immunology and Graduate Program in Immunology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Sukomon, Nattakan; Ungsupravate, Duangporn [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Limjindaporn, Thawornchai [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Department of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Akkarapatumwong, Varaporn [Institute of Molecular Biosciences, Mahidol University at Salaya Campus, Nakorn Pathom 73170 (Thailand); Noisakran, Sansanee [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Yenchitsomanus, Pa-thai, E-mail: grpye@mahidol.ac.th [Division of Medical Molecular Biology and BIOTEC-Medical Biotechnology Unit, Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand)

    2010-10-08

    Research highlights: {yields} Trafficking defect of kAE1 is a cause of dRTA but trafficking pathway of kAE1 has not been clearly described. {yields} Adaptor-related protein complex 1 {mu}1A (AP-1 mu1A) was firstly reported to interact with kAE1. {yields} The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. {yields} AP-1 mu1A knockdown showed a marked reduction of kAE1 on the cell membrane and its accumulation in endoplasmic reticulum. {yields} AP-1 mu1A has a critical role in kAE1 trafficking to the plasma membrane. -- Abstract: Kidney anion exchanger 1 (kAE1) mediates chloride (Cl{sup -}) and bicarbonate (HCO{sub 3}{sup -}) exchange at the basolateral membrane of kidney {alpha}-intercalated cells. Impaired trafficking of kAE1 leads to defect of the Cl{sup -}/HCO{sub 3}{sup -} exchange at the basolateral membrane and failure of proton (H{sup +}) secretion at the apical membrane, causing a kidney disease - distal renal tubular acidosis (dRTA). To gain a better insight into kAE1 trafficking, we searched for proteins physically interacting with the C-terminal region of kAE1 (Ct-kAE1), which contains motifs crucial for intracellular trafficking, by a yeast two-hybrid (Y2H) system. An adaptor-related protein complex 1 {mu}1A (AP-1 mu1A) subunit was found to interact with Ct-kAE1. The interaction between either Ct-kAE1 or full-length kAE1 and AP-1 mu1A were confirmed in human embryonic kidney (HEK) 293T by co-immunoprecipitation, affinity co-purification, co-localization, yellow fluorescent protein (YFP)-based protein fragment complementation assay (PCA) and GST pull-down assay. The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. Interestingly, suppression of endogenous AP-1 mu1A in HEK 293T by small interfering RNA (siRNA) decreased membrane localization of kAE1 and increased its intracellular accumulation, suggesting for the first time that AP-1 mu1A is involved in the kAE1

  7. A developmentally plastic adult mouse kidney cell line spontaneously generates multiple adult kidney structures

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Carol F., E-mail: carol-webb@omrf.org [Department of Cell Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Immunobiology and Cancer Research, Oklahoma Medical Research Foundation, Oklahoma City, OK (United States); Department of Microbiology and Immunology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Ratliff, Michelle L., E-mail: michelle-ratliff@omrf.org [Immunobiology and Cancer Research, Oklahoma Medical Research Foundation, Oklahoma City, OK (United States); Powell, Rebecca, E-mail: rebeccapowell@gmail.com [Department of Cell Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Wirsig-Wiechmann, Celeste R., E-mail: celeste-wirsig@ouhsc.edu [Department of Cell Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Lakiza, Olga, E-mail: olga-lakiza@ouhsc.edu [Department of Cell Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Obara, Tomoko, E-mail: tomoko-obara@ouhsc.edu [Department of Cell Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2015-08-07

    Despite exciting new possibilities for regenerative therapy posed by the ability to induce pluripotent stem cells, recapitulation of three-dimensional kidneys for repair or replacement has not been possible. ARID3a-deficient mouse tissues generated multipotent, developmentally plastic cells. Therefore, we assessed the adult mouse ARID3a−/− kidney cell line, KKPS5, which expresses renal progenitor surface markers as an alternative cell source for modeling kidney development. Remarkably, these cells spontaneously developed into multicellular nephron-like structures in vitro, and engrafted into immunocompromised medaka mesonephros, where they formed mouse nephron structures. These data implicate KKPS5 cells as a new model system for studying kidney development. - Highlights: • An ARID3a-deficient mouse kidney cell line expresses multiple progenitor markers. • This cell line spontaneously forms multiple nephron-like structures in vitro. • This cell line formed mouse kidney structures in immunocompromised medaka fish kidneys. • Our data identify a novel model system for studying kidney development.

  8. A developmentally plastic adult mouse kidney cell line spontaneously generates multiple adult kidney structures

    International Nuclear Information System (INIS)

    Webb, Carol F.; Ratliff, Michelle L.; Powell, Rebecca; Wirsig-Wiechmann, Celeste R.; Lakiza, Olga; Obara, Tomoko

    2015-01-01

    Despite exciting new possibilities for regenerative therapy posed by the ability to induce pluripotent stem cells, recapitulation of three-dimensional kidneys for repair or replacement has not been possible. ARID3a-deficient mouse tissues generated multipotent, developmentally plastic cells. Therefore, we assessed the adult mouse ARID3a−/− kidney cell line, KKPS5, which expresses renal progenitor surface markers as an alternative cell source for modeling kidney development. Remarkably, these cells spontaneously developed into multicellular nephron-like structures in vitro, and engrafted into immunocompromised medaka mesonephros, where they formed mouse nephron structures. These data implicate KKPS5 cells as a new model system for studying kidney development. - Highlights: • An ARID3a-deficient mouse kidney cell line expresses multiple progenitor markers. • This cell line spontaneously forms multiple nephron-like structures in vitro. • This cell line formed mouse kidney structures in immunocompromised medaka fish kidneys. • Our data identify a novel model system for studying kidney development

  9. Endoscopic clipping for gastrointestinal tumors. A method to define the target volume more precisely

    International Nuclear Information System (INIS)

    Riepl, M.; Klautke, G.; Fehr, R.; Fietkau, R.; Pietsch, A.

    2000-01-01

    Background: In many cases it is not possible to exactly define the extension of carcinoma of the gastrointestinal tract with the help of computertomography scans made for 3-D-radiation treatment planning. Consequently, the planning of external beam radiotherapy is made more difficult for the gross tumor volume as well as, in some cases, also for the clinical target volume. Patients and Methods: Eleven patients with macrosocpic tumors (rectal cancer n = 5, cardiac cancer n = 6) were included. Just before 3-D planning, the oral and aboral border of the tumor was marked endoscopically with hemoclips. Subsequently, CT scans for radiotherapy planning were made and the clinical target volume was defined. Five to 6 weeks thereafter, new CT scans were done to define the gross tumor volume for boost planning. Two investigators independently assessed the influence of the hemoclips on the different planning volumes, and whether the number of clips was sufficient to define the gross tumor volume. Results: In all patients, the implantation of the clips was done without complications. Start of radiotherapy was not delayed. With the help of the clips it was possible to exactly define the position and the extension of the primary tumor. The clinical target volume was modified according to the position of the clips in 5/11 patients; the gross tumor volume was modified in 7/11 patients. The use of the clips made the documentation and verification of the treatment portals by the simulator easier. Moreover, the clips helped the surgeon to define the primary tumor region following marked regression after neoadjuvant therapy in 3 patients. Conclusions: Endoscopic clipping of gastrointestinal tumors helps to define the tumor volumes more precisely in radiation therapy. The clips are easily recognized on the portal films and, thus, contribute to quality control. (orig.) [de

  10. Curative effect of sesame oil in a rat model of chronic kidney disease.

    Science.gov (United States)

    Liu, Chuan-Teng; Chien, Se-Ping; Hsu, Dur-Zong; Periasamy, Srinivasan; Liu, Ming-Yie

    2015-12-01

    Chronic kidney disease causes a progressive and irreversible loss of renal function. We investigated the curative effect of sesame oil, a natural, nutrient-rich, potent antioxidant, in a rat model of chronic kidney disease. Chronic kidney disease was induced by subcutaneously injecting uni-nephrectomized rats with deoxycorticosterone acetate (DOCA) and 1% NaCl [DOCA/salt] in drinking water. Four weeks later, the rats were gavaged with sesame oil (0.5 or 1 mL/kg per day) for 7 days. Renal injury, histopathological changes, hydroxyl radical, peroxynitrite, lipid peroxidation, Nrf2, osteopontin expression, and collagen were assessed 24 h after the last dose of sesame oil. Blood urea nitrogen, creatinine, urine volume, and albuminuria were significantly higher in the DOCA/salt treated rats than in control rats. Sesame oil significantly decreased these four tested parameters in DOCA/salt treated rats. In addition, creatinine clearance rate and nuclear Nrf2 expression were significantly decreased in the DOCA/salt treated rats compared to control rats. Sesame oil significantly decreased hydroxyl radical, peroxynitrite level, lipid peroxidation, osteopontin, and renal collagen deposition, but increased creatinine clearance rate and nuclear Nrf2 expression in DOCA/salt treated rats. We conclude that supplementation of sesame oil mitigates DOCA/salt induced chronic kidney disease in rats by activating Nrf2 and attenuating osteopontin expression and inhibiting renal fibrosis in rats. © 2015 Asian Pacific Society of Nephrology.

  11. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    Energy Technology Data Exchange (ETDEWEB)

    Fein, Douglas A; Fowble, Barbara L; Hanlon, Alexandra L; Hoffman, John P; Sigurdson, Elin R; Eisenberg, Burton L

    1995-07-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had {>=} 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy {+-} tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2

  12. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1995-01-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had ≥ 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy ± tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2% at

  13. Real-world experience of MitraClip for treatment of severe mitral regurgitation

    DEFF Research Database (Denmark)

    Chan, Pak Hei; She, Hoi Lam; Alegria-Barrero, Eduardo

    2012-01-01

     Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. Herein is reported our experience on MitraClip(®) for high-risk surgical candidates with severe mitral regurgitation (MR)....

  14. Iterative Signal Processing for Mitigation of Analog-to-Digital Converter Clipping Distortion in Multiband OFDMA Receivers

    Directory of Open Access Journals (Sweden)

    Markus Allén

    2012-01-01

    Full Text Available In modern wideband communication receivers, the large input-signal dynamics is a fundamental problem. Unintentional signal clipping occurs, if the receiver front-end with the analog-to-digital interface cannot respond to rapidly varying conditions. This paper discusses digital postprocessing compensation of such unintentional clipping in multiband OFDMA receivers. The proposed method iteratively mitigates the clipping distortion by exploiting the symbol decisions. The performance of the proposed method is illustrated with various computer simulations and also verified by concrete laboratory measurements with commercially available analog-to-digital hardware. It is shown that the clipping compensation algorithm implemented in a turbo decoding OFDM receiver is able to remove almost all the clipping distortion even under significant clipping in fading channel circumstances. That is to say, it is possible to nearly recover the receiver performance to the level, which would be achieved in the equivalent nonclipped situation.

  15. Finite element modeling of the human kidney for probabilistic occupant models: Statistical shape analysis and mesh morphing.

    Science.gov (United States)

    Yates, Keegan M; Untaroiu, Costin D

    2018-04-16

    Statistical shape analysis was conducted on 15 pairs (left and right) of human kidneys. It was shown that the left and right kidney were significantly different in size and shape. In addition, several common modes of kidney variation were identified using statistical shape analysis. Semi-automatic mesh morphing techniques have been developed to efficiently create subject specific meshes from a template mesh with a similar geometry. Subject specific meshes as well as probabilistic kidney meshes were created from a template mesh. Mesh quality remained about the same as the template mesh while only taking a fraction of the time to create the mesh from scratch or morph with manually identified landmarks. This technique can help enhance the quality of information gathered from experimental testing with subject specific meshes as well as help to more efficiently predict injury by creating models with the mean shape as well as models at the extremes for each principal component. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A mouse model of alcoholic liver fibrosis-associated acute kidney injury identifies key molecular pathways

    International Nuclear Information System (INIS)

    Furuya, Shinji; Chappell, Grace A.; Iwata, Yasuhiro; Uehara, Takeki; Kato, Yuki; Kono, Hiroshi; Bataller, Ramon; Rusyn, Ivan

    2016-01-01

    Clinical data strongly indicate that acute kidney injury (AKI) is a critical complication in alcoholic hepatitis, an acute-on-chronic form of liver failure in patients with advanced alcoholic fibrosis. Development of targeted therapies for AKI in this setting is hampered by the lack of an animal model. To enable research into molecular drivers and novel therapies for fibrosis- and alcohol-associated AKI, we aimed to combine carbon tetrachloride (CCl 4 )-induced fibrosis with chronic intra-gastric alcohol feeding. Male C57BL/6J mice were administered a low dose of CCl 4 (0.2 ml/kg 2 × week/6 weeks) followed by alcohol intragastrically (up to 25 g/kg/day for 3 weeks) and with continued CCl 4 . We observed that combined treatment with CCl 4 and alcohol resulted in severe liver injury, more pronounced than using each treatment alone. Importantly, severe kidney injury was evident only in the combined treatment group. This mouse model reproduced distinct pathological features consistent with AKI in human alcoholic hepatitis. Transcriptomic analysis of kidneys revealed profound effects in the combined treatment group, with enrichment for damage-associated pathways, such as apoptosis, inflammation, immune-response and hypoxia. Interestingly, Havcr1 and Lcn2, biomarkers of AKI, were markedly up-regulated. Overall, this study established a novel mouse model of fibrosis- and alcohol-associated AKI and identified key mechanistic pathways. - Highlights: • Acute kidney injury (AKI) is a critical complication in alcoholic hepatitis • We developed a novel mouse model of fibrosis- and alcohol-associated AKI • This model reproduces key molecular and pathological features of human AKI • This animal model can help identify new targeted therapies for alcoholic hepatitis

  17. What kind of erotic film clips should we use in female sex research? An exploratory study.

    Science.gov (United States)

    Woodard, Terri L; Collins, Karen; Perez, Mindy; Balon, Richard; Tancer, Manuel E; Kruger, Michael; Moffat, Scott; Diamond, Michael P

    2008-01-01

    Erotic film clips are used in sex research, including studies of female sexual dysfunction and arousal. However, little is known about which clips optimize female sexual response. Furthermore, their use is not well standardized. To identify the types of film clips that are most mentally appealing and physically arousing to women for use in future sexual function and dysfunction studies; to explore the relationship between mental appeal and reported physical arousal; to characterize the content of the films that were found to be the most and least appealing and arousing. Twenty-one women viewed 90 segments of erotic film clips. They rated how (i) mentally appealing and (ii) how physically aroused they were by each clip. The data were analyzed by descriptive statistics. The means of the mental and self-reported physical responses were calculated to determine the most and least appealing/arousing film clips. Pearson correlations were calculated to assess the relationship between mental appeal and reported physical arousal. Self-reported mental and physical arousal. Of 90 film clips, 18 were identified as the most mentally appealing and physically arousing while nine were identified as the least mentally appealing and physically arousing. The level of mental appeal positively correlated with the level of perceived physical arousal in both categories (r = 0.61, P Erotic film clips reliably produced a state of self-reported arousal in women. The most appealing and arousing films tended to depict heterosexual vaginal intercourse. Film clips with these attributes should be used in future research of sexual function and response of women.

  18. Effect of apical meristem clipping on carbon allocation and morphological development of white oak seedlings

    Science.gov (United States)

    Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch

    1994-01-01

    Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...

  19. Psychiatric disorder associated with vacuum-assisted breast biopsy clip placement: a case report

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2008-10-01

    Full Text Available Abstract Introduction Vacuum-assisted breast biopsy is a minimally invasive technique that has been used increasingly in the treatment of mammographically detected, non-palpable breast lesions. Clip placement at the biopsy site is standard practice after vacuum-assisted breast biopsy. Case presentation We present the case of a 62-year-old woman with suspicious microcalcifications in her left breast. The patient was informed about vacuum-assisted breast biopsy, including clip placement. During the course of taking the patient's history, she communicated excellently, her demeanor was normal, she disclosed no intake of psychiatric medication and had not been diagnosed with any psychiatric disorders. Subsequently, the patient underwent vacuum-assisted breast biopsy (11 G under local anesthesia. A clip was placed at the biopsy site. The pathological diagnosis was of sclerosing adenosis. At the 6-month mammographic follow-up, the radiologist mentioned the existence of the metallic clip in her breast. Subsequently, the woman presented complaining about "being spied [upon] by an implanted clip in [her] breast" and repeatedly requested the removal of the clip. The patient was referred to the specialized psychiatrist of our breast unit for evaluation. The Mental State Examination found that systematized paranoid ideas of persecutory type dominated her daily routines. At the time, she believed that the implanted clip was one of several pieces of equipment being used to keep her under surveillance, the other equipment being her telephone, cameras and television. Quite surprisingly, she had never had a consultation with a mental health professional. The patient appeared depressed and her insight into her condition was impaired. The prevalent diagnosis was schizotypal disorder, whereas the differential diagnosis comprised delusional disorder of persecutory type, affective disorder with psychotic features or comorbid delusional disorder with major depression

  20. Impact of Clipping versus Coiling on Postoperative Hemodynamics and Pulmonary Edema after Subarachnoid Hemorrhage

    Directory of Open Access Journals (Sweden)

    Nobutaka Horie

    2014-01-01

    Full Text Available Volume management is critical for assessment of cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH. This multicenter prospective cohort study compared the impact of surgical clipping versus endovascular coiling on postoperative hemodynamics and pulmonary edema in patients with SAH. Hemodynamic parameters were measured for 14 days using a transpulmonary thermodilution system. The study included 202 patients, including 160 who underwent clipping and 42 who underwent coiling. There were no differences in global ejection fraction (GEF, cardiac index, systemic vascular resistance index, or global end-diastolic volume index between the clipping and coiling groups in the early period. However, extravascular lung water index (EVLWI and pulmonary vascular permeability index (PVPI were significantly higher in the clipping group in the vasospasm period. Postoperative C-reactive protein (CRP level was higher in the clipping group and was significantly correlated with postoperative brain natriuretic peptide level. Multivariate analysis found that PVPI and GEF were independently associated with high EVLWI in the early period, suggesting cardiogenic edema, and that CRP and PVPI, but not GEF, were independently associated with high EVLWI in the vasospasm period, suggesting noncardiogenic edema. In conclusion, clipping affects postoperative CRP level and may thereby increase noncardiogenic pulmonary edema in the vasospasm period. His trial is registered with University Hospital Medical Information Network UMIN000003794.

  1. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum; Al-Rabah, Abdullatif R.; Masood, Mudassir; Al-Naffouri, Tareq Y.

    2014-01-01

    at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate

  2. Detection of LSB+/-1 steganography based on co-occurrence matrix and bit plane clipping

    Science.gov (United States)

    Abolghasemi, Mojtaba; Aghaeinia, Hassan; Faez, Karim; Mehrabi, Mohammad Ali

    2010-01-01

    Spatial LSB+/-1 steganography changes smooth characteristics between adjoining pixels of the raw image. We present a novel steganalysis method for LSB+/-1 steganography based on feature vectors derived from the co-occurrence matrix in the spatial domain. We investigate how LSB+/-1 steganography affects the bit planes of an image and show that it changes more least significant bit (LSB) planes of it. The co-occurrence matrix is derived from an image in which some of its most significant bit planes are clipped. By this preprocessing, in addition to reducing the dimensions of the feature vector, the effects of embedding were also preserved. We compute the co-occurrence matrix in different directions and with different dependency and use the elements of the resulting co-occurrence matrix as features. This method is sensitive to the data embedding process. We use a Fisher linear discrimination (FLD) classifier and test our algorithm on different databases and embedding rates. We compare our scheme with the current LSB+/-1 steganalysis methods. It is shown that the proposed scheme outperforms the state-of-the-art methods in detecting the LSB+/-1 steganographic method for grayscale images.

  3. T1-mapping for assessment of ischemia-induced acute kidney injury and prediction of chronic kidney disease in mice

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, Marcel; Wacker, Frank; Hartung, Dagmar [Hannover Medical School, Department of Radiology, Hannover (Germany); Hannover Medical School, REBIRTH Cluster of Excellence, Hannover (Germany); Peperhove, Matti; Tewes, Susanne; Barrmeyer, Amelie [Hannover Medical School, Department of Radiology, Hannover (Germany); Rong, Song [Hannover Medical School, Department of Nephrology, Hannover (Germany); Zunyi Medical College, Laboratory of Organ Transplantation, Zunyi (China); Gerstenberg, Jessica; Haller, Herman; Gueler, Faikah [Hannover Medical School, Department of Nephrology, Hannover (Germany); Mengel, Michael [University of Alberta, Department of Laboratory Medicine and Pathology, Edmonton (Canada); Meier, Martin [Hannover Medical School, REBIRTH Cluster of Excellence, Hannover (Germany); Hannover Medical School, Institute for Animal Science, Hannover (Germany); Chen, Rongjun [Hannover Medical School, Department of Nephrology, Hannover (Germany); Zhejiang University, The Kidney Disease Center of the First Affiliated Hospital, Hangzhou (China)

    2014-09-15

    To investigate whether T1-mapping allows assessment of acute kidney injury (AKI) and prediction of chronic kidney disease (CKD) in mice. AKI was induced in C57Bl/6N mice by clamping of the right renal pedicle for 35 min (moderate AKI, n = 26) or 45 min (severe AKI, n = 23). Sham animals served as controls (n = 9). Renal histology was assessed in the acute (day 1 + day 7; d1 + d7) and chronic phase (d28) after AKI. Furthermore, longitudinal MRI-examinations (prior to until d28 after surgery) were performed using a 7-Tesla magnet. T1-maps were calculated from a fat-saturated echoplanar inversion recovery sequence, and mean and relative T1-relaxation times were determined. Renal histology showed severe tubular injury at d1 + d7 in both AKI groups, whereas, at d28, only animals with prolonged 45-min ischemia showed persistent signs of AKI. Following both AKI severities T1-values significantly increased and peaked at d7. T1-times in the contralateral kidney without AKI remained stable. At d7 relative T1-values in the outer stripe of the outer medulla were significantly higher after severe than after moderate AKI (138 ± 2 % vs. 121 ± 3 %, p = 0.001). T1-elevation persisted until d28 only after severe AKI. Already at d7 T1 in the outer stripe of the outer medulla correlated with kidney volume loss indicating CKD (r = 0.83). T1-mapping non-invasively detects AKI severity in mice and predicts further outcome. (orig.)

  4. T1-mapping for assessment of ischemia-induced acute kidney injury and prediction of chronic kidney disease in mice

    International Nuclear Information System (INIS)

    Hueper, Katja; Gutberlet, Marcel; Wacker, Frank; Hartung, Dagmar; Peperhove, Matti; Tewes, Susanne; Barrmeyer, Amelie; Rong, Song; Gerstenberg, Jessica; Haller, Herman; Gueler, Faikah; Mengel, Michael; Meier, Martin; Chen, Rongjun

    2014-01-01

    To investigate whether T1-mapping allows assessment of acute kidney injury (AKI) and prediction of chronic kidney disease (CKD) in mice. AKI was induced in C57Bl/6N mice by clamping of the right renal pedicle for 35 min (moderate AKI, n = 26) or 45 min (severe AKI, n = 23). Sham animals served as controls (n = 9). Renal histology was assessed in the acute (day 1 + day 7; d1 + d7) and chronic phase (d28) after AKI. Furthermore, longitudinal MRI-examinations (prior to until d28 after surgery) were performed using a 7-Tesla magnet. T1-maps were calculated from a fat-saturated echoplanar inversion recovery sequence, and mean and relative T1-relaxation times were determined. Renal histology showed severe tubular injury at d1 + d7 in both AKI groups, whereas, at d28, only animals with prolonged 45-min ischemia showed persistent signs of AKI. Following both AKI severities T1-values significantly increased and peaked at d7. T1-times in the contralateral kidney without AKI remained stable. At d7 relative T1-values in the outer stripe of the outer medulla were significantly higher after severe than after moderate AKI (138 ± 2 % vs. 121 ± 3 %, p = 0.001). T1-elevation persisted until d28 only after severe AKI. Already at d7 T1 in the outer stripe of the outer medulla correlated with kidney volume loss indicating CKD (r = 0.83). T1-mapping non-invasively detects AKI severity in mice and predicts further outcome. (orig.)

  5. Daily Intake of Grape Powder Prevents the Progression of Kidney Disease in Obese Type 2 Diabetic ZSF1 Rats

    Directory of Open Access Journals (Sweden)

    Salwa M. K. Almomen

    2017-03-01

    Full Text Available Individuals living with metabolic syndrome (MetS such as diabetes and obesity are at high risk for developing chronic kidney disease (CKD. This study investigated the beneficial effect of whole grape powder (WGP diet on MetS-associated CKD. Obese diabetic ZSF1 rats, a kidney disease model with MetS, were fed WGP (5%, w/w diet for six months. Kidney disease was determined using blood and urine chemical analyses, and histology. When compared to Vehicle controls, WGP intake did not change the rat bodyweight, but lowered their kidney, liver and spleen weight, which were in parallel with the lower serum glucose and the higher albumin or albumin/globin ratio. More importantly, WGP intake improved the renal function as urination and proteinuria decreased, or it prevented kidney tissue damage in these diabetic rats. The renal protection of WGP diet was associated with up-regulation of antioxidants (Dhcr24, Gstk1, Prdx2, Sod2, Gpx1 and Gpx4 and downregulation of Txnip (for ROS production in the kidneys. Furthermore, addition of grape extract reduced H2O2-induced cell death of cultured podocytes. In conclusion, daily intake of WGP reduces the progression of kidney disease in obese diabetic rats, suggesting a protective function of antioxidant-rich grape diet against CKD in the setting of MetS.

  6. Kidney epithelium specific deletion of kelch-like ECH-associated protein 1 (Keap1) causes hydronephrosis in mice.

    Science.gov (United States)

    Noel, Sanjeev; Arend, Lois J; Bandapalle, Samatha; Reddy, Sekhar P; Rabb, Hamid

    2016-08-02

    Transcription factor Nrf2 protects from experimental acute kidney injury (AKI) and is promising to limit progression in human chronic kidney disease (CKD) by upregulating multiple antioxidant genes. We recently demonstrated that deletion of Keap1, the endogenous inhibitor of Nrf2, in T lymphocytes significantly protects from AKI. In this study, we investigated the effect of Keap1 deletion on Nrf2 mediated antioxidant response in the renal tubular epithelial cells. We deleted Keap1 exon 2 and 3 in the renal tubular epithelial cells by crossing Ksp-Cre mice with Keap1 floxed (Keap1 (f/f)) mice. Deletion of Keap1 gene in the kidney epithelial cells of Ksp-Keap1 (-/-) mice and its effect on Nrf2 target gene expression was performed using PCR and real-time PCR respectively. Histological evaluation was performed on H&E stained sections. Complete blood count, serum and urine analysis were performed to assess systemic effects of defective kidney development. Student's T test was used to determine statistical difference between the groups. Ksp-Cre resulted in the deletion of Keap1 exon 2 and 3 and subsequent upregulation of Nrf2 target genes, Nqo1, Gclm and Gclc in the kidney epithelial cells of Ksp-Keap1 (-/-) mice at baseline. Renal epithelial cell specific deletion of Keap1 in Ksp-Keap1 (-/-) mice caused marked renal pelvic expansion and significant compression of medullary parenchyma consistent with hydronephrosis in both (3 month-old) males and females. Kidneys from 6 month-old Ksp-Keap1 (-/-) mice showed progressive hydronephrosis. Hematological, biochemical and urinary analysis showed significantly higher red blood cell count (p = 0.04), hemoglobin (p = 0.01), hematocrit (p = 0.02), mean cell volume (p = 0.02) and mean cell hemoglobin concentration (p = 0.003) in Ksp-Keap1 (-/-) mice in comparison to Keap1 (f/f) mice. These unexpected findings demonstrate that Keap1 deletion in renal tubular epithelial cells results in an abnormal kidney

  7. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Centre, Institute of Radiation Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of)

    2017-12-15

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  8. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    International Nuclear Information System (INIS)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-01-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  9. [Clip Sheets from BOCES. Opportunities. Health. Careers. = Oportunidades. Salud. Una Camera En...

    Science.gov (United States)

    State Univ. of New York, Geneseo. Coll. at Geneseo. Migrant Center.

    This collection of 83 clip sheets, or classroom handouts, was created to help U.S. migrants learn more about health, careers, and general "opportunities" including education programs. They are written in both English and Spanish and are presented in an easily understandable format. Health clip-sheet topics include the following: Abuse; AIDS;…

  10. From benchmarking HITS-CLIP peak detection programs to a new method for identification of miRNA-binding sites from Ago2-CLIP data.

    Science.gov (United States)

    Bottini, Silvia; Hamouda-Tekaya, Nedra; Tanasa, Bogdan; Zaragosi, Laure-Emmanuelle; Grandjean, Valerie; Repetto, Emanuela; Trabucchi, Michele

    2017-05-19

    Experimental evidence indicates that about 60% of miRNA-binding activity does not follow the canonical rule about the seed matching between miRNA and target mRNAs, but rather a non-canonical miRNA targeting activity outside the seed or with a seed-like motifs. Here, we propose a new unbiased method to identify canonical and non-canonical miRNA-binding sites from peaks identified by Ago2 Cross-Linked ImmunoPrecipitation associated to high-throughput sequencing (CLIP-seq). Since the quality of peaks is of pivotal importance for the final output of the proposed method, we provide a comprehensive benchmarking of four peak detection programs, namely CIMS, PIPE-CLIP, Piranha and Pyicoclip, on four publicly available Ago2-HITS-CLIP datasets and one unpublished in-house Ago2-dataset in stem cells. We measured the sensitivity, the specificity and the position accuracy toward miRNA binding sites identification, and the agreement with TargetScan. Secondly, we developed a new pipeline, called miRBShunter, to identify canonical and non-canonical miRNA-binding sites based on de novo motif identification from Ago2 peaks and prediction of miRNA::RNA heteroduplexes. miRBShunter was tested and experimentally validated on the in-house Ago2-dataset and on an Ago2-PAR-CLIP dataset in human stem cells. Overall, we provide guidelines to choose a suitable peak detection program and a new method for miRNA-target identification. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Future of clip-on weapon sights: pros and cons from an applications perspective

    Science.gov (United States)

    Knight, C. Reed; Greenslade, Ken; Francisco, Glen

    2015-05-01

    US Domestic, International, allied Foreign National Warfighters and Para-Military First Responders (Police, SWAT, Special Operations, Law Enforcement, Government, Security and more) are put in harm's way all the time. To successfully complete their missions and return home safely are the primary goals of these professionals. Tactical product improvements that affect mission effectiveness and solider survivability are pivotal to understanding the past, present and future of Clip-On in-line weapon sights. Clip-On Weapon Sight (WS) technology was deemed an interim solution by the US Government for use until integrated and fused (day/night multi-sensor) Weapon Sights (WSs) were developed/fielded. Clip-On has now become the solution of choice by Users, Warriors, Soldiers and the US Government. SWaP-C (size, weight and power -cost) has been improved through progressive advances in Clip-On Image Intensified (I2), passive thermal, LL-CMOS and fused technology. Clip-On Weapon Sights are now no longer mounting position sensitive. Now they maintain aim point boresight, so they can be used for longer ranges with increased capabilities while utilizing the existing zeroed weapon and daysight optic. Active illuminated low-light level (both analog I2 and digital LL-CMOS) imaging is rightfully a real-world technology, proven to deliver daytime and low-light level identification confidence. Passive thermal imaging is also a real-world technology, proven to deliver daytime, nighttime and all-weather (including dirty battlefield) target detection confidence. Image processing detection algorithms with intelligent analytics provide documented promise to improve confidence by reducing Users, Warriors and Soldiers' work-loads and improving overall system engagement solution outcomes. In order to understand the future of Clip-On in-line weapon sights, addressing pros and cons, this paper starts with an overview of historical weapon sight applications, technologies and stakeholder decisions

  12. PAPR Reduction of FBMC by Clipping and Its Iterative Compensation

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2012-01-01

    Full Text Available Physical layers of communication systems using Filter Bank Multicarrier (FBMC as a modulation scheme provide low out-of-band leakage but suffer from the large Peak-to-Average Power Ratio (PAPR of the transmitted signal. Two special FBMC schemes are investigated in this paper: the Orthogonal Frequency Division Multiplexing (OFDM and the Staggered Multitone (SMT. To reduce the PAPR of the signal, time domain clipping is applied in both schemes. If the clipping is not compensated, the system performance is severely affected. To avoid this degradation, an iterative noise cancelation technique, Bussgang Noise Cancelation (BNC, is applied in the receiver. It is shown that clipping can be a good means for reducing the PAPR, especially for the SMT scheme. A novel modified BNC receiver is presented for SMT. It is shown how this technique can be implemented in real-life applications where special requirements must be met regarding the spectral characteristics of the transmitted signal.

  13. Acute Cholangitis following Intraductal Migration of Surgical Clips 10 Years after Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Natalie E. Cookson

    2015-01-01

    Full Text Available Background. Laparoscopic cholecystectomy represents the gold standard approach for treatment of symptomatic gallstones. Surgery-associated complications include bleeding, bile duct injury, and retained stones. Migration of surgical clips after cholecystectomy is a rare complication and may result in gallstone formation “clip cholelithiasis”. Case Report. We report a case of a 55-year-old female patient who presented with right upper quadrant pain and severe sepsis having undergone an uncomplicated laparoscopic cholecystectomy 10 years earlier. Computed tomography (CT imaging revealed hyperdense material in the common bile duct (CBD compatible with retained calculus. Endoscopic retrograde cholangiopancreatography (ERCP revealed appearances in keeping with a migrated surgical clip within the CBD. Balloon trawl successfully extracted this, alleviating the patient’s jaundice and sepsis. Conclusion. Intraductal clip migration is a rarely encountered complication after laparoscopic cholecystectomy which may lead to choledocholithiasis. Appropriate management requires timely identification and ERCP.

  14. A mouse model of alcoholic liver fibrosis-associated acute kidney injury identifies key molecular pathways

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Shinji; Chappell, Grace A.; Iwata, Yasuhiro [Department of Veterinary Integrative Biosciences, Texas A& M University, College Station, TX (United States); Uehara, Takeki; Kato, Yuki [Laboratory of Veterinary Pathology, Osaka Prefecture University, Osaka (Japan); Kono, Hiroshi [First Department of Surgery, University of Yamanashi, Yamanashi (Japan); Bataller, Ramon [Division of Gastroenterology & Hepatology, Department of Medicine, University of North Carolina, Chapel Hill, NC (United States); Rusyn, Ivan, E-mail: irusyn@tamu.edu [Department of Veterinary Integrative Biosciences, Texas A& M University, College Station, TX (United States)

    2016-11-01

    Clinical data strongly indicate that acute kidney injury (AKI) is a critical complication in alcoholic hepatitis, an acute-on-chronic form of liver failure in patients with advanced alcoholic fibrosis. Development of targeted therapies for AKI in this setting is hampered by the lack of an animal model. To enable research into molecular drivers and novel therapies for fibrosis- and alcohol-associated AKI, we aimed to combine carbon tetrachloride (CCl{sub 4})-induced fibrosis with chronic intra-gastric alcohol feeding. Male C57BL/6J mice were administered a low dose of CCl{sub 4} (0.2 ml/kg 2 × week/6 weeks) followed by alcohol intragastrically (up to 25 g/kg/day for 3 weeks) and with continued CCl{sub 4}. We observed that combined treatment with CCl{sub 4} and alcohol resulted in severe liver injury, more pronounced than using each treatment alone. Importantly, severe kidney injury was evident only in the combined treatment group. This mouse model reproduced distinct pathological features consistent with AKI in human alcoholic hepatitis. Transcriptomic analysis of kidneys revealed profound effects in the combined treatment group, with enrichment for damage-associated pathways, such as apoptosis, inflammation, immune-response and hypoxia. Interestingly, Havcr1 and Lcn2, biomarkers of AKI, were markedly up-regulated. Overall, this study established a novel mouse model of fibrosis- and alcohol-associated AKI and identified key mechanistic pathways. - Highlights: • Acute kidney injury (AKI) is a critical complication in alcoholic hepatitis • We developed a novel mouse model of fibrosis- and alcohol-associated AKI • This model reproduces key molecular and pathological features of human AKI • This animal model can help identify new targeted therapies for alcoholic hepatitis.

  15. Geographic disparity in kidney transplantation under KAS.

    Science.gov (United States)

    Zhou, Sheng; Massie, Allan B; Luo, Xun; Ruck, Jessica M; Chow, Eric K H; Bowring, Mary G; Bae, Sunjae; Segev, Dorry L; Gentry, Sommer E

    2017-12-12

    The Kidney Allocation System fundamentally altered kidney allocation, causing a substantial increase in regional and national sharing that we hypothesized might impact geographic disparities. We measured geographic disparity in deceased donor kidney transplant (DDKT) rate under KAS (6/1/2015-12/1/2016), and compared that with pre-KAS (6/1/2013-12/3/2014). We modeled DSA-level DDKT rates with multilevel Poisson regression, adjusting for allocation factors under KAS. Using the model we calculated a novel, improved metric of geographic disparity: the median incidence rate ratio (MIRR) of transplant rate, a measure of DSA-level variation that accounts for patient casemix and is robust to outlier values. Under KAS, MIRR was 1.75 1.81 1.86 for adults, meaning that similar candidates across different DSAs have a median 1.81-fold difference in DDKT rate. The impact of geography was greater than the impact of factors emphasized by KAS: having an EPTS score ≤20% was associated with a 1.40-fold increase (IRR =  1.35 1.40 1.45 , P geographic disparities with KAS (P = .3). Despite extensive changes to kidney allocation under KAS, geography remains a primary determinant of access to DDKT. © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.

  16. Use of activation analysis method for determining trace elements in human nail clippings

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1999-01-01

    This work presents results obtained in nail clipping samples analyses. These nail samples were collected from healthy group of individuals and from patients with cystic fibrosis disease. Irradiation of nail clippings was carried out with a thermal neutron flux from 10 11 to 10 13 n.cm -2 .s -1 at the IEA-R1m nuclear research reactor and the elements Al, As, Br, Ca, cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn were determined. The results obtained for healthy group were within the range of concentrations published, for normal population. However for several elements, the group of patients presented higher concentrations than those presented for healthy individuals. The precision and the accuracy of the results were evaluated by analyzing reference materials NIST 1577b Bovine Liver and 1566a Oyster Tissue. (author)

  17. Creating computer aided 3D model of spleen and kidney based based on Visible Human Project

    International Nuclear Information System (INIS)

    Aldur, Muhammad M.

    2005-01-01

    To investigate the efficacy of computer aided 3-dimensional (3D) reconstruction technique on visualization and modeling of gross anatomical structures with an affordable methodology applied on the spleen and kidney. From The Visible Human Project Dataset cryosection images, developed by the National Library of Medicine, the spleen and kidney sections were preferred to be used due to their highly distinct contours. The software used for the reconstruction were Surf Driver 3.5.3 for Mac and Cinema 4D X L version 7.1 for Mac OS X. This study was carried out in May 2004 at the Department of Anatomy, Hacettepe University, Ankara, Turkey. As a result of this study, it is determined that these 2 programs could be effectively used both for 3D modeling of the mentioned organs and volumetric analyses on these models. It is also seen that it is possible to hold the physical models of these gross anatomical digital ones with stereolithography technique by means of the data exchange file format provided by the program and present such images as anaglyph. Surf Driver 3.5.3 for Mac OS and Cinema 4 DXL version 7.1 for Mac OS X can be used effectively for reconstruction of gross anatomical structures from serial parallel sections with distinct contours such as spleen and kidney and the animation of models. These software constitute a highly effective way of getting volumetric calculations, spatial relations and morphometrical measurements of reconstructed structures. (author)

  18. Practical application of stereological methods in experimental kidney animal models.

    Science.gov (United States)

    Fernández García, María Teresa; Núñez Martínez, Paula; García de la Fuente, Vanessa; Sánchez Pitiot, Marta; Muñiz Salgueiro, María Del Carmen; Perillán Méndez, Carmen; Argüelles Luis, Juan; Astudillo González, Aurora

    The kidneys are vital organs responsible for excretion, fluid and electrolyte balance and hormone production. The nephrons are the kidney's functional and structural units. The number, size and distribution of the nephron components contain relevant information on renal function. Stereology is a branch of morphometry that applies mathematical principles to obtain three-dimensional information from serial, parallel and equidistant two-dimensional microscopic sections. Because of the complexity of stereological studies and the lack of scientific literature on the subject, the aim of this paper is to clearly explain, through animal models, the basic concepts of stereology and how to calculate the main kidney stereological parameters that can be applied in future experimental studies. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Subclinical kidney injury before and 1 year after bariatric surgery among adolescents with severe obesity.

    Science.gov (United States)

    Xiao, Nianzhou; Devarajan, Prasad; Inge, Thomas H; Jenkins, Todd M; Bennett, Michael; Mitsnefes, Mark M

    2015-06-01

    To assess subclinical kidney injury in adolescents with severe obesity by measuring biomarkers of early kidney disease and to assess changes in the levels of these biomarkers following bariatric procedures. Twenty-two adolescents undergoing bariatric surgery with no microalbuminuria and normal kidney function were selected. Urinary NGAL, IL-18, and KIM-1 were measured at baseline, 6 and 12 months postoperatively. Biomarker levels were compared to 44 age-gender-matched lean controls. Subjects with obesity had a mean baseline BMI of 48 kg/m(2) that decreased by 34% at 1-year follow-up. Urine NGAL, IL-18, and KIM-1 were significantly elevated in subjects with obesity compared to lean controls at baseline. The obese cohort had a further significant increase in NGAL and KIM-1 at 6 months, followed by decline at 1 year. The overall change in levels of all three biomarkers through 1 year after surgery, however, was not significant compared to baseline. Adolescent severe obesity is associated with increased urinary excretion of novel biomarkers of kidney injury, despite no microalbuminuria or decreased kidney function. This subclinical kidney injury persists 1 year after significant weight loss induced by bariatric surgery, suggesting that close, long-term follow-up of kidney status is warranted in these adolescents. © 2015 The Obesity Society.

  20. A Systematic Review and Meta-Analysis on Economic Comparison Between Endovascular Coiling Versus Neurosurgical Clipping for Ruptured Intracranial Aneurysms.

    Science.gov (United States)

    Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin

    2018-05-01

    Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2  = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2  = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2  = 96%; P China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.

  1. Kidney transplantation process in Brazil represented in business process modeling notation.

    Science.gov (United States)

    Peres Penteado, A; Molina Cohrs, F; Diniz Hummel, A; Erbs, J; Maciel, R F; Feijó Ortolani, C L; de Aguiar Roza, B; Torres Pisa, I

    2015-05-01

    Kidney transplantation is considered to be the best treatment for people with chronic kidney failure, because it improves the patients' quality of life and increases their length of survival compared with patients undergoing dialysis. The kidney transplantation process in Brazil is defined through laws, decrees, ordinances, and resolutions, but there is no visual representation of this process. The aim of this study was to analyze official documents to construct a representation of the kidney transplantation process in Brazil with the use of business process modeling notation (BPMN). The methodology for this study was based on an exploratory observational study, document analysis, and construction of process diagrams with the use of BPMN. Two rounds of validations by specialists were conducted. The result includes the kidney transplantation process in Brazil representation with the use of BPMN. We analyzed 2 digital documents that resulted in 2 processes with 45 total of activities and events, 6 organizations involved, and 6 different stages of the process. The constructed representation makes it easier to understand the rules for the business of kidney transplantation and can be used by the health care professionals involved in the various activities within this process. Construction of a representation with language appropriate for the Brazilian lay public is underway. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Systematic kidney disease management in a population with diabetes mellitus: turning the tide of kidney failure.

    Science.gov (United States)

    Rayner, Hugh C; Hollingworth, Lee; Higgins, Robert; Dodds, Simon

    2011-10-01

    A significant proportion of patients with diabetes mellitus do not get the benefit of treatment that would reduce their risk of progressive kidney disease and reach a nephrologist once significant loss of kidney function has already occurred. Systematic disease management of patients with diabetes and kidney disease. Diverse population (approximately 800,000) in and around Birmingham, West Midlands, UK. Number of outpatient appointments, estimated glomerular filtration rate (eGFR) at first contact with nephrologist, number of patients starting kidney replacement therapy (KRT) and mode of KRT at start. Identification of patients with low or deteriorating trend in eGFR from weekly database review, specialist diabetes-kidney clinic, self-management of blood pressure and transfer to multidisciplinary clinic >12 months before end-stage kidney disease. New patients increased from 62 in 2003 to 132 in 2010; follow-ups fell from 251 to 174. Median eGFR at first clinic visit increased from 28.8 ml/min/1.73 m(2) (range 6.1-67.0) in 2000/2001 to 35.0 (11.1-147.5) in 2010 (pmanagement across a large population significantly improves patient outcomes, increases the productivity of a specialist service and could reduce healthcare costs compared with the current model of care.

  3. Role of TRPV1 channels in ischemia/reperfusion-induced acute kidney injury.

    Directory of Open Access Journals (Sweden)

    Lan Chen

    Full Text Available OBJECTIVES: Transient receptor potential vanilloid 1 (TRPV1 -positive sensory nerves are widely distributed in the kidney, suggesting that TRPV1-mediated action may participate in the regulation of renal function under pathophysiological conditions. Stimulation of TRPV1 channels protects against ischemia/reperfusion (I/R-induced acute kidney injury (AKI. However, it is unknown whether inhibition of these channels is detrimental in AKI or not. We tested the role of TRPV1 channels in I/R-induced AKI by modulating these channels with capsaicin (TRPV1 agonist, capsazepine (TRPV1 antagonist and using Trpv1-/- mice. METHODS AND RESULTS: Anesthetized C57BL/6 mice were subjected to 25 min of renal ischemia and 24 hrs of reperfusion. Mice were pretreated with capsaicin (0.3 mg/kg body weight or capsazepine (50 mg/kg body weight. Capsaicin ameliorated the outcome of AKI, as measured by serum creatinine levels, tubular damage,neutrophil gelatinase-associated lipocalin (NGAL abundance and Ly-6B.2 positive polymorphonuclear inflammatory cells in injured kidneys. Neither capsazepine nor deficiency of TRPV1 did deteriorate renal function or histology after AKI. Measurements of endovanilloids in kidney tissue indicate that 20-hydroxyeicosatetraeonic acid (20-HETE or epoxyeicosatrienoic acids (EETs are unlikely involved in the beneficial effects of capsaicin on I/R-induced AKI. CONCLUSIONS: Activation of TRPV1 channels ameliorates I/R-induced AKI, but inhibition of these channels does not affect the outcome of AKI. Our results may have clinical implications for long-term safety of renal denervation to treat resistant hypertension in man, with respect to the function of primary sensory nerves in the response of the kidney to ischemic stimuli.

  4. Polycystin-1 promotes PKCα-mediated NF-κB activation in kidney cells

    International Nuclear Information System (INIS)

    Banzi, Manuela; Aguiari, Gianluca; Trimi, Viky; Mangolini, Alessandra; Pinton, Paolo; Witzgall, Ralph; Rizzuto, Rosario; Senno, Laura del

    2006-01-01

    Polycystin-1 (PC1), the PKD1 gene product, is a membrane receptor which regulates many cell functions, including cell proliferation and apoptosis, both typically increased in cyst lining cells in autosomal dominant polycystic kidney disease. Here we show that PC1 upregulates the NF-κB signalling pathway in kidney cells to prevent cell death. Human embryonic kidney cell lines (HEK293 CTT ), stably expressing a PC1 cytoplasmic terminal tail (CTT), presented increased NF-κB nuclear levels and NF-κB-mediated luciferase promoter activity. This, consistently, was reduced in HEK293 cells in which the endogenous PC1 was depleted by RNA interference. CTT-dependent NF-κB promoter activation was mediated by PKCα because it was blocked by its specific inhibitor Ro-320432. Furthermore, it was observed that apoptosis, which was increased in PC1-depleted cells, was reduced in HEK293 CTT cells and in porcine kidney LtTA cells expressing a doxycycline-regulated CTT. Staurosporine, a PKC inhibitor, and parthenolide, a NF-κB inhibitor, significantly reduced the CTT-dependent antiapoptotic effect. These data reveal, therefore, a novel pathway by which polycystin-1 activates a PKCα-mediated NF-κB signalling and cell survival

  5. Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.

    Science.gov (United States)

    Hu, Sudeng; Wang, Hanli; Kwong, Sam

    2012-04-01

    In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.

  6. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  7. 76 FR 26242 - Paper Clips From the People's Republic of China: Final Results of Expedited Sunset Review of...

    Science.gov (United States)

    2011-05-06

    ... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...

  8. Advantages in imaging results with titanium aneurysm clips (TiAl6V4)

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Weik, T.; Schmiedek, P.

    1995-01-01

    Aneurysm clips made of a titanium alloy (TiAl6V4) were used in clinical practice for the first time. The design of the clips is identical to the routinely used Yasargil series. In 30 patients, 38 symptomatic and asymptomatic aneurysms were fixed with 45 clips. Metallurgical advantages of the new alloy are better biocompatibility, less magnetic susceptibility, and lower X-ray density. The postoperative imaging results are superior to the conventionally used alloys with respect to artifact reduction in computed tomography, angiography, and magnetic resonance imaging. With a follow-up period of 7 months, a statement on biocompatibility cannot yet be given. (orig.) [de

  9. Ingested bread clip as an unexpected diagnostic tool.

    Science.gov (United States)

    Jay, Sharon M; Russell, Michael J; Lau, Yee C; Dunn, Joel W; Roberts, Ross

    2018-03-23

    We describe a case where a bread clip has in fact became lodged adjacent to a portion of small bowel affected by a deposit of previously undiagnosed metastatic serous carcinoma of likely ovarian origin.

  10. Capturing Students' Attention: Movie Clips Set the Stage for Learning in Abnormal Psychology.

    Science.gov (United States)

    Badura, Amy S.

    2002-01-01

    Presents results of a study that evaluated using popular movie clips, shown in the first class meeting of an abnormal psychology course, in relation to student enthusiasm. Compares two classes of female juniors, one using clips and one class not using them. States that the films portrayed psychological disorders. (CMK)

  11. 76 FR 31360 - Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Science.gov (United States)

    2011-05-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...

  12. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  13. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    NARCIS (Netherlands)

    Wever, K.E.; Geessink, F.J.; Brouwer, M.A.E.; Tillema, A.; Ritskes-Hoitinga, M.

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of

  14. Tubular kidney injury molecule-1 in protein-overload nephropathy

    NARCIS (Netherlands)

    van Timmeren, Mirjan M.; Bakker, Stephan J. L.; Vaidya, Vishal S.; Bailly, Veronique; Schuurs, Theo A.; Damman, Jeffrey; Stegeman, Coen A.; Bonventre, Joseph V.; van Goor, Harry

    Kim-1, a recently discovered membrane protein, is undetectable in normal kidneys but markedly induced in proximal tubules after ischemic and toxic injury. The function of Kim-1 is unclear, but it is implicated in damage/repair processes. The Kim-1 ectodomain is cleaved by metalloproteinases and

  15. The bovine kidney as an experimental model in urology: external gross anatomy.

    Science.gov (United States)

    Carvalho, Francismar S; Bagetti Filho, Hélio J S; Henry, Robert W; Pereira-Sampaio, Marco A

    2009-01-01

    The objective of this work was to obtain and record detailed and accurate measurements of the bovine kidney and to compare these new data with findings in humans. Thirty-eight bovine kidneys were used. The total number of lobes, along with the number of lobes located in the cranial polar, caudal polar and hilar regions, were recorded. Several measurements of the kidneys were made and evaluated. The hilar region presents the greatest length (mean of 76.87 mm) of the 3 renal regions of the kidney. The large area of the bovine renal hilus could make access to hilar structures easier than in the human kidney. The coefficient of variation for renal length was small (8.14%), while the coefficient of variation for the lobar number was high (26.82%). The number of renal lobes ranged from 13 to 35, with a mean of 20.62. The hilar region presents the highest number of lobes, while the cranial pole presents the lowest. The number of lobes in the cranial and caudal poles increases with the width of these regions. This is different from the hilar region, in which the lobar number increases with the length of the hilus. These data indicate that the adult bovine kidney can be used as a model for certain urologic procedures, but researchers must be aware that there are some major differences between the adult bovine kidney and the human kidney, as indicated by the data reported in this paper. (c) 2008 S. Karger AG, Basel.

  16. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases.

    Science.gov (United States)

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-02-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.

  17. Poly[ADP-ribose] polymerase-1 expression is related to cold ischemia, acute tubular necrosis, and delayed renal function in kidney transplantation.

    Directory of Open Access Journals (Sweden)

    Francisco O'Valle

    Full Text Available UNLABELLED: Cold ischemia time especially impacts on outcomes of expanded-criteria donor (ECD transplantation. Ischemia-reperfusion (IR injury produces excessive poly[ADP-Ribose] Polymerase-1 (PARP-1 activation. The present study explored the hypothesis that increased tubular expression of PARP-1 contributes to delayed renal function in suboptimal ECD kidney allografts and in non-ECD allografts that develop posttransplant acute tubular necrosis (ATN. MATERIALS AND METHODS: Nuclear PARP-1 immunohistochemical expression was studied in 326 paraffin-embedded renal allograft biopsies (193 with different degrees of ATN and 133 controls and in murine Parp-1 knockout model of IR injury. RESULTS: PARP-1 expression showed a significant relationship with cold ischemia time (r coefficient = 0.603, time to effective diuresis (r = 0.770, serum creatinine levels at biopsy (r = 0.649, and degree of ATN (r = 0.810 (p = 0.001, Pearson test. In the murine IR model, western blot showed an increase in PARP-1 that was blocked by Parp-1 inhibitor. Immunohistochemical study of PARP-1 in kidney allograft biopsies would allow early detection of possible delayed renal function, and the administration of PARP-1 inhibitors may offer a therapeutic option to reduce damage from IR in donor kidneys by preventing or minimizing ATN. In summary, these results suggest a pivotal role for PARP-1 in the ATN of renal transplantation. We propose the immunohistochemical assessment of PARP-1 in kidney allograft biopsies for early detection of a possible delayed renal function.

  18. Embryonic kidney function in a chronic renal failure model in rodents.

    Science.gov (United States)

    Fujimoto, Eisuke; Yamanaka, Shuichiro; Kurihara, Sho; Tajiri, Susumu; Izuhara, Luna; Katsuoka, Yuichi; Yokote, Shinya; Matsumoto, Kei; Kobayashi, Eiji; Okano, Hirotaka James; Chikaraishi, Tatsuya; Yokoo, Takashi

    2017-08-01

    Rapid advancements have been made in alternative treatments for renal diseases. Our goal for renal regeneration is to establish a kidney graft derived from human embryonic tissues. In this study, we investigated the effects of host renal failure on the structure and activity of transplanted embryonic kidney and bladder, and found that diuretics effectively induced urine production in the transplanted kidney. Uremic conditions were reproduced using a 5/6 renal infarction rat model. An embryonic kidney plus bladder (embryonic day 15) was isolated from a pregnant Lewis rat and transplanted into the para-aortic area of a 5/6 renal-infarcted Lewis rat. Following growth, the embryonic bladder was successfully anastomosed to the host ureter. We assessed graft function in terms of survival rates and found no differences between normal (n = 5) and renal failure (n = 8) groups (median survival: 70.5 vs 74.5 h; p = 0.331) in terms of survival, indicating that the grafts prolonged rat survival, even under renal failure conditions. Furosemide (n = 9) significantly increased urine volume compared with saline-treated controls (n = 7; p < 0.05), confirming that the grafts were functional. We also demonstrated the possibilities of an in vivo imaging system for determining the viability of transplanted embryonic kidney with bladder. The results of this study demonstrate that transplanted embryonic kidney and bladder can grow and function effectively, even under uremic conditions.

  19. Personalized 3D printed model of kidney and tumor anatomy: a useful tool for patient education.

    Science.gov (United States)

    Bernhard, Jean-Christophe; Isotani, Shuji; Matsugasumi, Toru; Duddalwar, Vinay; Hung, Andrew J; Suer, Evren; Baco, Eduard; Satkunasivam, Raj; Djaladat, Hooman; Metcalfe, Charles; Hu, Brian; Wong, Kelvin; Park, Daniel; Nguyen, Mike; Hwang, Darryl; Bazargani, Soroush T; de Castro Abreu, Andre Luis; Aron, Monish; Ukimura, Osamu; Gill, Inderbir S

    2016-03-01

    To assess the impact of 3D printed models of renal tumor on patient's understanding of their conditions. Patient understanding of their medical condition and treatment satisfaction has gained increasing attention in medicine. Novel technologies such as additive manufacturing [also termed three-dimensional (3D) printing] may play a role in patient education. A prospective pilot study was conducted, and seven patients with a primary diagnosis of kidney tumor who were being considered for partial nephrectomy were included after informed consent. All patients underwent four-phase multi-detector computerized tomography (MDCT) scanning from which renal volume data were extracted to create life-size patient-specific 3D printed models. Patient knowledge and understanding were evaluated before and after 3D model presentation. Patients' satisfaction with their specific 3D printed model was also assessed through a visual scale. After viewing their personal 3D kidney model, patients demonstrated an improvement in understanding of basic kidney physiology by 16.7 % (p = 0.018), kidney anatomy by 50 % (p = 0.026), tumor characteristics by 39.3 % (p = 0.068) and the planned surgical procedure by 44.6 % (p = 0.026). Presented herein is the initial clinical experience with 3D printing to facilitate patient's pre-surgical understanding of their kidney tumor and surgery.

  20. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast-conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1996-01-01

    recurrence was 2% at 5 years and 5% at 10 years for patients without clips compared to 5 and 11%, respectively, for patients with clips (p 0.01). Comparing the breast recurrence rates for patients with and without clips there was no significant difference for the following factors: chemotherapy, tamoxifen, negative, positive or close margins, reexcision, N1, and central or inner primary. Increased rates of breast recurrence were noted for patients with clips for the following variables: no adjuvant treatment (p < 0.001), unknown margins (p < 0.001), a single excision (p = 0.003), path N0 (p = 0.001), and outer location (p = 0.02). A forward stepwise multivariate analysis for all 1364 patients was performed using the aforementioned variables as well as the presence or absence of surgical clips and the primary surgeon. The surgeon (p = 0.03) and no adjuvant treatment (p = 0.01) significantly influenced breast recurrence. For patients with surgical clips the 10 year isolated breast recurrence rate was 21% for a single surgeon vs. 6% in the remainder of the group (p = 0.01). For patients with clips, this surgeon had unknown margins in 48% of cases compared to 10% overall (p 0.001). Excluding this surgeon from analysis the isolated breast recurrence for patients with clips was 6 vs. 5% for patients without clips (p = 0.18). Conclusions: Overall, there was a significant difference in the 10-year breast recurrence rate favoring women without clips despite more adverse prognostic factors. There was no difference in the breast recurrence rate for patients with or without surgical clips if careful attention to margin status was addressed. Failure to ink the surgical specimen resulting in unknown margins cannot be compensated for with the placement of surgical clips or treatment planning using CT to delineate the surgical bed

  1. Association of CYP1A1 gene polymorphism with chronic kidney disease: a case control study.

    Science.gov (United States)

    Siddarth, Manushi; Datta, Sudip K; Ahmed, Rafat S; Banerjee, Basu D; Kalra, Om P; Tripathi, Ashok K

    2013-07-01

    CYP1A1 is an important xenobiotic metabolizing enzyme, present in liver and kidney. Expression of CYP1A1 enzyme increases manifold when kidney cells are exposed to nephrotoxins/chemicals leading to oxidative stress-induced cell damage. To study the association of CYP1A1 gene polymorphism in patients of chronic kidney disease with unknown etiology (CKDU), we recruited 334 CKDU patients and 334 age and sex matched healthy controls. CYP1A1*2A and *2C polymorphisms were studied by PCR-RFLP and allele specific-PCR respectively. Subjects carrying at least one mutant allele of CYP1A1*2A (TC, CC) and *2C (AG, GG) were shown to be associated with 1.4-2-fold increased risk of CKDU. Also, genotypic combinations of hetero-/homozygous mutants of CYP1A1*2A (TC, CC) with hetero-/homozygous mutant genotypes of CYP1A1*2C (AG, GG) i.e. TC/AG (pCKDU with an odd ratio ranging 1.8-3.3 times approximately. This study demonstrates association of CYP1A1 polymorphisms with CKDU. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Level of headaches after surgical aneurysm clipping decreases significantly faster compared to endovascular coiled patients

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2017-04-01

    Full Text Available In incidental aneurysms, endovascular treatment can lead to post-procedural headaches. We studied the difference of surgical clipping vs. endovascular coiling in concern to post-procedural headaches in patients with ruptured aneurysms. Sixtyseven patients with aneurysmal subarachnoidal haemorrhage were treated in our department from September 1st 2015 - September 1st 2016. 43 Patients were included in the study and the rest was excluded because of late recovery or highgrade subarachnoid bleedings. Twenty-two were surgical treated and twenty-one were interventionally treated. We compared the post-procedural headaches at the time points of 24 h, 21 days, and 3 months after treatment using the visual analog scale (VAS for pain. After surgical clipping the headache score decreased for 8.8 points in the VAS, whereas the endovascular treated population showed a decrease of headaches of 3.3 points. This difference was highly statistical significant and remained significant even after 3 weeks where the pain score for the surgically treated patients was 0.68 and for the endovascular treated 1.8. After 3 months the pain was less than 1 for both groups with surgically treated patients scoring 0.1 and endovascular treated patients 0.9 (not significant. Clipping is relieving the headaches of patients with aneurysm rupture faster and more effective than endovascular coiling. This effect stays significant for at least 3 weeks and plays a crucial role in stress relieve during the acute and subacute ICU care of such patients.

  3. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    Science.gov (United States)

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  4. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates.

    Science.gov (United States)

    Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-04-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  5. Efficacy of Handwashing with Soap and Nail Clipping on Intestinal Parasitic Infections in School-Aged Children: A Factorial Cluster Randomized Controlled Trial.

    Science.gov (United States)

    Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco

    2015-06-01

    Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. In this trial, 367 parasite-negative school-aged children (aged 6-15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to

  6. Efficacy of Handwashing with Soap and Nail Clipping on Intestinal Parasitic Infections in School-Aged Children: A Factorial Cluster Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Mahmud Abdulkader Mahmud

    2015-06-01

    Full Text Available Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections.In this trial, 367 parasite-negative school-aged children (aged 6-15 y were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19% of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36% in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62. Similarly, 17% (95% CI: 12% to 22% of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32% in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95. Likewise, following the intervention, 13% (95% CI: 8% to 18% of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29% in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78. The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI

  7. MicroRNA transfection and AGO-bound CLIP-seq data sets reveal distinct determinants of miRNA action

    DEFF Research Database (Denmark)

    Wen, Jiayu; Parker, Brian J; Jacobsen, Anders

    2011-01-01

    the predictive effect of target flanking features. We observe distinct target determinants between expression-based and CLIP-based data. Target flanking features such as flanking region conservation are an important AGO-binding determinant-we hypothesize that CLIP experiments have a preference for strongly bound......Microarray expression analyses following miRNA transfection/inhibition and, more recently, Argonaute cross-linked immunoprecipitation (CLIP)-seq assays have been used to detect miRNA target sites. CLIP and expression approaches measure differing stages of miRNA functioning-initial binding of the mi...... miRNP-target interactions involving adjacent RNA-binding proteins that increase the strength of cross-linking. In contrast, seed-related features are major determinants in expression-based studies, but less so for CLIP-seq studies, and increased miRNA concentrations typical of transfection studies...

  8. Associations between Deceased-Donor Urine MCP-1 and Kidney Transplant Outcomes.

    Science.gov (United States)

    Mansour, S G; Puthumana, J; Reese, P P; Hall, I E; Doshi, M D; Weng, F L; Schröppel, B; Thiessen-Philbrook, H; Bimali, M; Parikh, C R

    2017-07-01

    Existing methods to predict recipient allograft function during deceased-donor kidney procurement are imprecise. Understanding the potential renal reparative role for monocyte chemoattractant protein-1 (MCP-1), a cytokine involved in macrophage recruitment after injury, might help predict allograft outcomes. We conducted a sub-study of the multicenter prospective Deceased Donor Study cohort, which evaluated deceased kidney donors from five organ procurement organizations from May 2010 to December 2013. We measured urine MCP-1 (uMCP-1) concentrations from donor samples collected at nephrectomy to determine associations with donor acute kidney injury (AKI), recipient delayed graft function (DGF), 6-month estimated GFR (eGFR), and graft failure. We also assessed perfusate MCP-1 concentrations from pumped kidneys for associations with DGF and 6-month eGFR. AKI occurred in 111 (9%) donors. Median (interquartile range) uMCP-1 concentration was higher in donors with AKI compared to donors without AKI (1.35 [0.41-3.93] ng/ml vs. 0.32 [0.11-0.80] ng/ml, p<0.001). DGF occurred in 756 (31%) recipients, but uMCP-1 was not independently associated with DGF. Higher donor uMCP-1 concentrations were independently associated with higher 6-month eGFR in those without DGF [0.77 (0.10, 1.45) ml/min/1.73m 2 per doubling of uMCP1]. However, there were no independent associations between uMCP-1 and graft failure over a median follow-up of about 2 years. Lastly, perfusate MCP-1 concentrations significantly increased during pump perfusion but were not associated with DGF or 6-month eGFR. Donor uMCP-1 concentrations were modestly associated with higher recipient 6-month eGFR in those without DGF. However, the results suggest that donor uMCP-1 has minimal clinical utility given no associations with graft failure.

  9. YUCSA: A CLIPS expert database system to monitor academic performance

    Science.gov (United States)

    Toptsis, Anestis A.; Ho, Frankie; Leindekar, Milton; Foon, Debra Low; Carbonaro, Mike

    1991-01-01

    The York University CLIPS Student Administrator (YUCSA), an expert database system implemented in C Language Integrated Processing System (CLIPS), for monitoring the academic performance of undergraduate students at York University, is discussed. The expert system component in the system has already been implemented for two major departments, and it is under testing and enhancement for more departments. Also, more elaborate user interfaces are under development. We describe the design and implementation of the system, problems encountered, and immediate future plans. The system has excellent maintainability and it is very efficient, taking less than one minute to complete an assessment of one student.

  10. The diagnostic importance of the new marker KIM-1 in kidney damage

    Directory of Open Access Journals (Sweden)

    Zofia Marchewka

    2013-07-01

    Full Text Available In recent years, the rapid development of scientific research led to the introduction of strategies based on new markers that allow for estimation of the latent disease period before the clinical symptoms of actual kidney failure are revealed.The experimental tests carried out on animals and cell lines derived from the proximal tubule have made possible the detection of genes that are induced early after hypoxia [1].The protein products of these genes can be considered as useful markers for the diagnosis of renal failure. The induction of gene KIM-1 (called Kidney Injury Molecule-1 results in the formation of protein that can be considered as a diagnostic marker.This work describes the data on the structure, biological function and importance of determining the concentrations of KIM-1 in the diagnosis of drug-induced toxicity and kidney damage.

  11. Detrimental effects of rat mesenchymal stromal cell pre-treatment in a model of acute kidney rejection

    Directory of Open Access Journals (Sweden)

    Martina eSeifert

    2012-07-01

    Full Text Available Mesenchymal stromal cells (MSC have shown immunomodulatory and tissue repair potential including partial tolerance induction by pre-treatment of donor-specific cells in a rat heart transplantation model. Very recently, we could show that autologous MSC attenuated ischemia reperfusion injury in a highly mismatched donor-recipient rat kidney transplant model. Therefore, we investigated donor-specific MSC pre-treatment in this rat kidney transplantation model to study whether graft function could be improved, or if tolerance could be induced.Donor- and recipient-type MSC or PBS as a control were injected i.v. four days before kidney transplantation. Mycophenolate mofetil (MMF immunosuppression (20 mg/kg body weight was applied for 7 days. Kidney grafts and spleens were harvested between days 8-10 and analyzed by quantitative RT-PCR and immunohistology. In addition, creatinine levels in the blood were measured and serum was screened for the presence of donor-specific antibodies.Surprisingly, application of both donor- and recipient-specific MSC resulted in enhanced humoral immune responses verified by intragraft B cell infiltration and complement factor C4d deposits. Moreover, signs of inflammation and rejection were generally enhanced in both MSC-treated groups relative to PBS control group. Additionally, pre-treatment with donor-specific MSC significantly enhanced the level of donor-specific antibody formation when compared with PBS- or recipient-MSC-treated groups. Pre-treatment with both MSC types resulted in a higher degree of kidney cortex tissue damage and elevated creatinine levels at the time point of rejection. Thus, MSC pre-sensitization in this model impairs the allograft outcome.Our data from this pre-clinical kidney transplantation model indicate that pre-operative MSC administration may not be optimal in kidney transplantation and caution must be exerted before moving forward with clinical studies in order to avoid adverse effects.

  12. Perfusion of tumor-bearing kidneys as a model for scintigraphic screening of monoclonal antibodies

    International Nuclear Information System (INIS)

    van Dijk, J.; Oosterwijk, E.; van Kroonenburgh, M.J.; Jonas, U.; Fleuren, G.J.; Pauwels, E.K.; Warnaar, S.O.

    1988-01-01

    Tumor-bearing human kidneys were used in an ex vivo perfusion model to screen monoclonal antibodies, recognizing renal cell carcinoma-associated antigens for diagnostic potential in vivo. Perfusion of tumor-bearing kidneys with /sup 99m/Tc-labeled G250 and RC38 antibody resulted in visualization of the tumor, whereas perfusion with two other monoclonal antibodies, RC2 and RC4, did not lead to tumor visualization. Uptake of radiolabel in normal kidney tissue was low for G250 and RC38 antibody. Tumor-to-kidney tissue ratios after perfusion with G250 and RC38 antibody were 2.7 and 2.2, respectively. After rinsing for 3 hr with unlabeled perfusion fluid the tumor-to-kidney tissue ratios increased to 8.6 for G250 antibody and to 2.7 for RC38 antibody. We conclude that perfusion of tumor-bearing human kidneys with radiolabeled monoclonal antibodies is a relatively simple way to evaluate renal cell carcinoma associated monoclonal antibodies as diagnostic agents in vivo

  13. Failure of acute procedural success predicts adverse outcome after percutaneous edge-to-edge mitral valve repair with MitraClip.

    Science.gov (United States)

    Puls, Miriam; Tichelbäcker, Tobias; Bleckmann, Annalen; Hünlich, Mark; von der Ehe, Katrin; Beuthner, Bo Eric; Rüter, Karin; Beißbarth, Tim; Seipelt, Ralf; Schöndube, Friedrich; Hasenfuß, Gerd; Schillinger, Wolfgang

    2014-01-01

    MitraClip implantation is evolving as a potential alternative treatment to conventional surgery in high-risk patients with significant mitral regurgitation (MR). However, outcome predictors are under-investigated. The aim of this study was to identify predictors of midterm mortality and heart failure rehospitalisation after percutaneous mitral valve repair with MitraClip. A total of 150 consecutive patients were followed for a median of 463 days. Survival analyses were performed for baseline characteristics, risk scores and failure of acute procedural success (APS) defined as persisting MR grade 3+ or 4+. Univariate significant risk stratifiers were tested in multivariate analyses using a Cox proportional hazards model. Overall survival was 96% at 30 days, 79.5% at 12 months, and 62% at two years. Multivariate analysis identified APS failure (HR 2.13, p=0.02), NYHA Class IV at baseline (HR 2.11, p=0.01) and STS score ≥12 (HR 2.20, pfailure (HR 2.31, p=0.01) and NYHA Class IV at baseline (HR 1.89, p=0.03) as significant independent predictors of heart failure rehospitalisation. Furthermore, a post-procedural significant decrease in hospitalisation rate could only be observed after successful interventions (0.89±1.07 per year before vs. 0.54±0.96 after implantation, p=0.01). Patients with severely dilated and overloaded ventricles who did not meet EVEREST II eligibility criteria were at higher risk of APS failure. The failure of acute procedural success proved to have the most important impact on outcome after MitraClip implantation.

  14. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    Science.gov (United States)

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  15. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  16. A modified elliptical formula to estimate kidney collagen content in a model of chronic kidney disease.

    Science.gov (United States)

    Nieto, Jake A; Zhu, Janice; Duan, Bin; Li, Jingsong; Zhou, Ping; Paka, Latha; Yamin, Michael A; Goldberg, Itzhak D; Narayan, Prakash

    2018-01-01

    The extent of scarring or renal interstitial collagen deposition in chronic kidney disease (CKD) can only be ascertained by highly invasive, painful and sometimes risky, tissue biopsy. Interestingly, while CKD-related abnormalities in kidney size can often be visualized using ultrasound, not only does the ellipsoid formula used today underestimate true renal size, but the calculated renal size does not inform tubulointerstitial collagen content. We used coronal kidney sections from healthy mice and mice with kidney disease to develop a new formula for estimating renal parenchymal area. While treating the kidney as an ellipse with the major axis (a) the polar distance, this technique involves extending the minor axis (b) into the renal pelvis to obtain a new minor axis, be. The calculated renal parenchymal area is remarkably similar to the true or measured area. Biochemically determined kidney collagen content revealed a strong and positive correlation with the calculated renal parenchymal area. Picrosirius red staining for tubulointerstitial collagen also correlated with calculated renal parenchymal area. The extent of renal scarring, i.e. kidney interstitial collagen content, can now be computed by making just two axial measurements which can easily be accomplished via noninvasive imaging of this organ.

  17. The effect of music video clips on adolescent boys' body image, mood, and schema activation.

    Science.gov (United States)

    Mulgrew, Kate E; Volcevski-Kostas, Diana; Rendell, Peter G

    2014-01-01

    There is limited research that has examined experimentally the effects of muscular images on adolescent boys' body image, with no research specifically examining the effects of music television. The aim of the current study was to examine the effects of viewing muscular and attractive singers in music video clips on early, mid, and late adolescent boys' body image, mood, and schema activation. Participants were 180 boys in grade 7 (mean age = 12.73 years), grade 9 (mean age = 14.40 years) or grade 11 (mean age = 16.15 years) who completed pre- and post-test measures of mood and body satisfaction after viewing music videos containing male singers of muscular or average appearance. They also completed measures of schema activation and social comparison after viewing the clips. The results showed that the boys who viewed the muscular clips reported poorer upper body satisfaction, lower appearance satisfaction, lower happiness, and more depressive feelings compared to boys who viewed the clips depicting singers of average appearance. There was no evidence of increased appearance schema activation but the boys who viewed the muscular clips did report higher levels of social comparison to the singers. The results suggest that music video clips are a powerful form of media in conveying information about the male ideal body shape and that negative effects are found in boys as young as 12 years.

  18. The Effects of Dexmedetomidine on Secondary Acute Lung and Kidney Injuries in the Rat Model of Intra-Abdominal Sepsis

    Directory of Open Access Journals (Sweden)

    Uğur Koca

    2013-01-01

    Full Text Available In the present study, the effects of dexmedetomidine on secondary lung and kidney injuries were studied in the rat model of intra-abdominal sepsis by immunohistological and biochemical examinations. We measured serum creatinine, kidney tissue malondialdehide and plasma neutrophil gelatinase-associated lipocalin levels. In order to evaluate tissue injury we determined kidney tissue mononuclear cell infiltration score, alveolar macrophage count, histological kidney and lung injury scores and kidney and lung tissue immunoreactivity scores. We demonstrated that dexmedetomidine attenuates sepsis-induced lung and kidney injuries and apoptosis in the rat model of sepsis. There is still need for comparative studies in order to determine the effects of dexmedetomidine on organ functions in early human sepsis.

  19. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J; Bailey, Daniel P; Elsenousi, Abdussalam; Roitberg, Ben Z; Bernardo, Antonio; Banerjee, P Pat; Charbel, Fady T

    2015-03-01

    With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.

  20. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    Science.gov (United States)

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant

  1. A mathematical model for the kidney and estimative of the specific absorbed fractions by Monte Carlo method

    International Nuclear Information System (INIS)

    Todo, A.S.

    1980-01-01

    Presently, the estimates of specific absorbed fractions in various organs of a heterogeneous phantom are based on Monte Carlo calculation for monoenergetic photons uniformly distributed in the organs of an adult phantom. But, it is known that the kidney and some other organs (for example the skeleton) do not retain the radionuclides in an uniform manner in its internal region. So, we developed a model for the kidney including the cortex, medulla and collecting region. This model was utilized to estimate the specific absorbed fractions, for monoenergetic photons or electrons, in various organs of a heterogeneous phantom, when sources were uniformly distributed in each region of the kidney. All results obtained in this work were compared with those using a homogeneous model for the kidney as presented in ORNL-5000. (Author) [pt

  2. Application and validation of Cox regression models in a single-center series of double kidney transplantation.

    Science.gov (United States)

    Santori, G; Fontana, I; Bertocchi, M; Gasloli, G; Magoni Rossi, A; Tagliamacco, A; Barocci, S; Nocera, A; Valente, U

    2010-05-01

    A useful approach to reduce the number of discarded marginal kidneys and to increase the nephron mass is double kidney transplantation (DKT). In this study, we retrospectively evaluated the potential predictors for patient and graft survival in a single-center series of 59 DKT procedures performed between April 21, 1999, and September 21, 2008. The kidney recipients of mean age 63.27 +/- 5.17 years included 16 women (27%) and 43 men (73%). The donors of mean age 69.54 +/- 7.48 years included 32 women (54%) and 27 men (46%). The mean posttransplant dialysis time was 2.37 +/- 3.61 days. The mean hospitalization was 20.12 +/- 13.65 days. Average serum creatinine (SCr) at discharge was 1.5 +/- 0.59 mg/dL. In view of the limited numbers of recipient deaths (n = 4) and graft losses (n = 8) that occurred in our series, the proportional hazards assumption for each Cox regression model with P DKT (P = .043), and SCr 6 months post-DKT (P = .017). All significant univariate models for graft survival passed the Schoenfeld test. A final multivariate model retained SCr at 6 months (beta = 1.746, P = .042) and donor SCr (beta = .767, P = .090). In our analysis, SCr at 6 months seemed to emerge from both univariate and multivariate Cox models as a potential predictor of graft survival among DKT. Multicenter studies with larger recipient populations and more graft losses should be performed to confirm our findings. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  3. [The diagnostic importance of the new marker KIM-1 in kidney damage].

    Science.gov (United States)

    Marchewka, Zofia; Płonka, Joanna

    2013-07-24

    In recent years, the rapid development of scientific research led to the introduction of strategies based on new markers that allow for estimation of the latent disease period before the clinical symptoms of actual kidney failure are revealed. The experimental tests carried out on animals and cell lines derived from the proximal tubule have made possible the detection of genes that are induced early after hypoxia. The protein products of these genes can be considered as useful markers for the diagnosis of renal failure. The induction of gene KIM-1 (called Kidney Injury Molecule-1) results in the formation of protein that can be considered as a diagnostic marker. This work describes the data on the structure, biological function and importance of determining the concentrations of KIM-1 in the diagnosis of drug-induced toxicity and kidney damage.

  4. The "Isms" of Art. Introduction to the 2001-2002 Clip and Save Art Prints.

    Science.gov (United States)

    Hubbard, Guy

    2001-01-01

    Provides an introduction to the 2001-2002 Clip and Save Art Prints that will focus on ten art movements from the past 150 years. Includes information on three art movements, or "isms": Classicism, Romanticism, and Realism. Discusses the Clip and Save Art Print format and provides information on three artists. (CMK)

  5. Effects of Mitral Annulus Remodeling Following MitraClip Procedure on Reduction of Functional Mitral Regurgitation.

    Science.gov (United States)

    Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José

    2016-11-01

    The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Telomere attrition, kidney function, and prevalent chronic kidney disease in the United States.

    Science.gov (United States)

    Mazidi, Moshen; Rezaie, Peyman; Covic, Adriac; Malyszko, Jolanta; Rysz, Jacek; Kengne, Andre Pascal; Banach, Maciej

    2017-10-06

    Telomere length is an emerging novel biomarker of biologic age, cardiovascular risk and chronic medical conditions. Few studies have focused on the association between telomere length (TL) and kidney function. We investigated the association between TL and kidney function/prevalent chronic kidney disease (CKD) in US adults. The National Health and Nutrition Examination Survey (NHANES) participants with measured data on kidney function and TL from 1999 to 2002 were included. Estimated glomerular filtration rate (eGFR) was based on CKD Epidemiology Collaboration (CKD-EPI) equation. Urinary albumin excretion was assessed using urinary albumin-creatinine ratio (ACR). We used multivariable adjusted linear and logistic regression models, accounting for the survey design and sample weights. Of the 10568 eligible participants, 48.0% ( n =5020) were men. Their mean age was 44.1 years. eGFR significantly decreased and ACR significantly increased across increasing quarters of TL (all p function remained robust even after adjusting for potential confounding factors, but the association between TL and ACR was only borderline significant (β-coefficient= -0.012, p =0.056). The association of kidney function with a marker of cellular senescence suggests an underlying mechanism influencing the progression of nephropathy.

  7. Our History Clips: Collaborating for the Common Good

    Science.gov (United States)

    Bailey, Beatrice N.

    2017-01-01

    This case study reveals how middle school social studies teachers within a professional development program are encouraging their students to use multiple disciplinary literacies to create Our History Clips as they also work toward developing a classroom community of engaged student citizens.

  8. ASTP 15th Anniversary Clip-Media Release

    Science.gov (United States)

    1990-01-01

    This release is comprised of 5 separate clips, including the following: CL 762 Astronauts/Cosmonauts Visit to KSC and Walt Disney World; CL 739 ASTP Joint Crew Activities; CL 748 ASTP Astronauts/Cosmonauts Horlock Ranch Visit; CL 758 T-21 ASTP Training - US/USSR; and CL 743 ASTP Joint Crew Training in the Soviet Union.

  9. Clipping Versus Coiling in the Management of Posterior Communicating Artery Aneurysms with Third Nerve Palsy: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne

    2016-03-01

    To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Clips supporting and spacing flanged sheets of reflective insulation

    International Nuclear Information System (INIS)

    Carr, R.W.

    1980-01-01

    This invention relates to clips, spacing and supporting flanged sheets of reflective insulation used to encase the main body and associated piping of nuclear reactors to minimize heat and radiation losses. (UK)

  11. Urine Levels of Defensin α1 Reflect Kidney Injury in Leptospirosis Patients

    Directory of Open Access Journals (Sweden)

    Haorile Chagan-Yasutan

    2016-09-01

    Full Text Available Leptospirosis is a zoonotic disease whose severe forms are often accompanied by kidney dysfunction. In the present study, urinary markers were studied for potential prediction of disease severity. Urine samples from 135 patients with or without leptospirosis at San Lazaro Hospital, the Philippines, were analyzed. Urine levels of defensin α1 (uDA1 were compared with those of neutrophil gelatinase-associated lipocalin (uNGAL and N-acetyl-β-d-glucosidase (uNAG. Serum creatinine (Cr was used as a marker of kidney injury. The levels of uDA1/Cr, uNGAL/Cr, and uNAG/Cr were positive in 46%, 90%, and 80% of leptospirosis patients, and 69%, 70%, and 70% of non-leptospirosis patients, respectively. In leptospirosis patients, the correlation of uDA1/Cr, uNGAL/Cr and uNAG/Cr levels with serum Cr were r = 0.3 (p < 0.01, r = 0.29 (p < 0.01, and r = 0.02 (p = 0.81, respectively. uDA1/Cr levels were correlated with uNGAL/Cr levels (r = 0.49, p < 0.01 and uNAG/Cr levels (r = 0.47, p < 0.0001 in leptospirosis patients. These findings suggest that uDA1, uNGAL, and uNAG were elevated in leptospirosis patients and reflected various types of kidney damage. uDA1 and uNGAL can be used to track kidney injury in leptospirosis patients because of their correlation with the serum Cr level.

  12. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Investigation of Sequence Clipping and Structural Heterogeneity of an HIV Broadly Neutralizing Antibody by a Comprehensive LC-MS Analysis

    Science.gov (United States)

    Ivleva, Vera B.; Schneck, Nicole A.; Gollapudi, Deepika; Arnold, Frank; Cooper, Jonathan W.; Lei, Q. Paula

    2018-05-01

    CAP256 is one of the highly potent, broadly neutralizing monoclonal antibodies (bNAb) designed for HIV-1 therapy. During the process development of one of the constructs, an unexpected product-related impurity was observed via microfluidics gel electrophoresis. A panel of complementary LC-MS analyses was applied for the comprehensive characterization of CAP256 which included the analysis of the intact and reduced protein, the middle-up approach, and a set of complementary peptide mapping techniques and verification of the disulfide bonds. The designed workflow allowed to identify a clip within a protruding acidic loop in the CDR-H3 region of the heavy chain, which can lead to the decrease of bNAb potency. This characterization explained the origin of the additional species reflected by the reducing gel profile. An intra-loop disulfide bond linking the two fragments was identified, which explained why the non-reducing capillary electrophoresis (CE) profile was not affected. The extensive characterization of CAP256 post-translational modifications was performed to investigate a possible cause of CE profile complexity and to illustrate other structural details related to this molecule's biological function. Two sites of the engineered Tyr sulfation were verified in the antigen-binding loop, and pyroglutamate formation was used as a tool for monitoring the extent of antibody clipping. Overall, the comprehensive LC-MS study was crucial to (1) identify the impurity as sequence clipping, (2) pinpoint the clipping location and justify its susceptibility relative to the molecular structure, (3) lead to an upstream process optimization to mitigate product quality risk, and (4) ultimately re-engineer the sequence to be clip-resistant. [Figure not available: see fulltext.

  14. Assessment of acute kidney injury with T1 mapping MRI following solid organ transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Peperhove, Matti; Vo Chieu, Van Dai; Gutberlet, Marcel; Hartung, Dagmar; Tewes, Susanne; Wacker, Frank; Hueper, Katja [Hannover Medical School, Diagnostic and Interventional Radiology, Hannover (Germany); Jang, Mi-Sun; Gwinner, Wilfried; Haller, Hermann; Gueler, Faikah [Nephrology, Hannover Medical School, Hannover (Germany); Warnecke, Gregor; Fegbeutel, Christiane; Haverich, Axel [Hannover Medical School, Cardiothoracic, Transplantation and Vascular Surgery, Hannover (Germany); Lehner, Frank [Hannover Medical School, General, Abdominal and Transplant Surgery, Hannover (Germany); Braesen, Jan Hinrich [Pathology, Hannover Medical School, Hannover (Germany)

    2018-01-15

    To evaluate T1 mapping as a non-invasive, functional MRI biomarker in patients shortly after solid organ transplantation to detect acute postsurgical kidney damage and to correlate T1 times with renal function. 101 patients within 2 weeks after solid organ transplantation (49 kidney transplantation, 52 lung transplantation) and 14 healthy volunteers were examined by MRI between July 2012 and April 2015 using the modified Look-Locker inversion recovery (MOLLI) sequence. T1 times in renal cortex and medulla and the corticomedullary difference were compared between groups using one-way ANOVA adjusted for multiple comparison with the Tukey test, and T1 times were correlated with renal function using Pearson's correlation. Compared to healthy volunteers T1 times were significantly increased after solid organ transplantation in the renal cortex (healthy volunteers 987 ± 102 ms; kidney transplantation 1299 ± 101 ms, p < 0.001; lung transplantation 1058 ± 96 ms, p < 0.05) and to a lesser extent in the renal medulla. Accordingly, the corticomedullary difference was diminished shortly after solid organ transplantation. T1 changes were more pronounced following kidney compared to lung transplantation, were associated with the stage of renal impairment and significantly correlated with renal function. T1 mapping may be helpful for early non-invasive assessment of acute kidney injury and renal pathology following major surgery such as solid organ transplantation. (orig.)

  15. Assessment of acute kidney injury with T1 mapping MRI following solid organ transplantation

    International Nuclear Information System (INIS)

    Peperhove, Matti; Vo Chieu, Van Dai; Gutberlet, Marcel; Hartung, Dagmar; Tewes, Susanne; Wacker, Frank; Hueper, Katja; Jang, Mi-Sun; Gwinner, Wilfried; Haller, Hermann; Gueler, Faikah; Warnecke, Gregor; Fegbeutel, Christiane; Haverich, Axel; Lehner, Frank; Braesen, Jan Hinrich

    2018-01-01

    To evaluate T1 mapping as a non-invasive, functional MRI biomarker in patients shortly after solid organ transplantation to detect acute postsurgical kidney damage and to correlate T1 times with renal function. 101 patients within 2 weeks after solid organ transplantation (49 kidney transplantation, 52 lung transplantation) and 14 healthy volunteers were examined by MRI between July 2012 and April 2015 using the modified Look-Locker inversion recovery (MOLLI) sequence. T1 times in renal cortex and medulla and the corticomedullary difference were compared between groups using one-way ANOVA adjusted for multiple comparison with the Tukey test, and T1 times were correlated with renal function using Pearson's correlation. Compared to healthy volunteers T1 times were significantly increased after solid organ transplantation in the renal cortex (healthy volunteers 987 ± 102 ms; kidney transplantation 1299 ± 101 ms, p < 0.001; lung transplantation 1058 ± 96 ms, p < 0.05) and to a lesser extent in the renal medulla. Accordingly, the corticomedullary difference was diminished shortly after solid organ transplantation. T1 changes were more pronounced following kidney compared to lung transplantation, were associated with the stage of renal impairment and significantly correlated with renal function. T1 mapping may be helpful for early non-invasive assessment of acute kidney injury and renal pathology following major surgery such as solid organ transplantation. (orig.)

  16. Subclinical chronic kidney disease modifies the diagnosis of experimental acute kidney injury.

    Science.gov (United States)

    Succar, Lena; Pianta, Timothy J; Davidson, Trent; Pickering, John W; Endre, Zoltán H

    2017-09-01

    Extensive structural damage within the kidney must be present before serum creatinine increases. However, a subclinical phase of chronic kidney disease (CKD) usually goes undetected. Here we tested whether experimental subclinical CKD would modify functional and damage biomarker profiles of acute kidney injury (AKI). Subclinical CKD was induced in rats by adenine or aristolochic acid models but without increasing serum creatinine. After prolonged recovery (three to six weeks), AKI was induced with a subnephrotoxic dose of cisplatin. Urinary levels of kidney injury molecule-1 (KIM-1), cytochrome C, monocyte chemotactic protein-1 (MCP-1), clusterin, and interleukin-18 increased during CKD induction, without an increase in serum creatinine. After AKI in adenine-induced CKD, serum creatinine increased more rapidly, while increased urinary KIM-1, clusterin, and MCP-1 were delayed and reduced. Increased serum creatinine and biomarker excretion were associated with diffuse tubulointerstitial injury in the outer stripe of outer medulla coupled with over 50% cortical damage. Following AKI in aristolochic acid-induced CKD, increased serum creatinine, urinary KIM-1, clusterin, MCP-1, cytochrome C, and interleukin-18 concentrations and excretion were greater at day 21 than day 42 and inversely correlated with cortical injury. Subclinical CKD modified functional and damage biomarker profiles in diametrically opposite ways. Functional biomarker profiles were more sensitive, while damage biomarker diagnostic thresholds and increases were diminished and delayed. Damage biomarker concentrations and excretion were inversely linked to the extent of prior cortical damage. Thus, thresholds for AKI biomarkers may need to be lower or sampling delayed in the known presence of CKD. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  17. Modeling a Mobile Health Management Business Model for Chronic Kidney Disease.

    Science.gov (United States)

    Lee, Ying-Li; Chang, Polun

    2016-01-01

    In these decades, chronic kidney disease (CKD) has become a global public health problem. Information technology (IT) tools have been used widely to empower the patients with chronic disease (e.g., diabetes and hypertension). It is also a potential application to advance the CKD care. In this project, we analyzed the requirements of a mobile health management system for healthcare workers, patients and their families to design a health management business model for CKD patients.

  18. Kidney injury and heme oxygenase-1

    Directory of Open Access Journals (Sweden)

    Hai-xing MAI

    2012-02-01

    Full Text Available     Heme oxygenase-1 (HO-1 is one of the main pathways to degrade heme in mammals, and the main degradation products are free iron (Fe2+, carbon monoxide (CO, and bilirubin. Heme plays an important role in promoting cell survival, circulation of intracellular substrates, and immune regulation. Previous studies suggest that HO-1 pathway is an important internal factor in determining the susceptibility and severity of acute kidney injury (AKI. The induction of HO-1 expression can attenuate the severity of renal ischemia-reperfusion injury (IRI, and the inhibition of HO-1 expression will aggravate IRI. The present article summarizes the latest advances in research abroad and at home on protective mechanism by which HO-1 prevents AKI to further deepen our understanding of the role of HO-1 in the treatment of AKI.   

  19. Three-port laparoscopic cholecystectomy by harmonic dissection without cystic duct and artery clipping.

    Science.gov (United States)

    Tebala, Giovanni D

    2006-05-01

    The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.

  20. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Declercq David

    2008-01-01

    Full Text Available Abstract Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  1. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Maxime Colas

    2008-02-01

    Full Text Available Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  2. Association Between Inflammatory Markers and Progression to Kidney Dysfunction: Examining Different Assessment Windows in Patients With Type 1 Diabetes.

    Science.gov (United States)

    Baker, Nathaniel L; Hunt, Kelly J; Stevens, Danielle R; Jarai, Gabor; Rosen, Glenn D; Klein, Richard L; Virella, Gabriel; Lopes-Virella, Maria F

    2018-01-01

    To determine whether biomarkers of inflammation and endothelial dysfunction are associated with the development of kidney dysfunction and the time frame of their association. Biomarkers were measured at four time points during 28 years of treatment and follow-up in patients with type 1 diabetes in the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) cohort. In addition to traditional biomarkers of inflammation (C-reactive protein and fibrinogen), we measured interleukin-6 (IL-6) and soluble tumor necrosis factor receptors 1 and 2 (sTNFR-1/2), markers of endothelial dysfunction (soluble intracellular adhesion molecule-1, vascular cell adhesion molecule-1, and E-selectin [sE-selectin]), and fibrinolysis (total and active plasminogen activator inhibitor-1 [PAI-1]). Renal outcomes were defined as progression to incident chronic kidney disease (stage 3 or more severe) or macroalbuminuria (albumin excretion rate ≥300 mg/24 h). Prospective multivariate event-time analyses were used to determine the association of each biomarker with each subsequent event within prespecified intervals (3-year and 10-year windows). Multivariate event-time models indicated that several markers of inflammation (sTNFR-1/2), endothelial dysfunction (sE-selectin), and clotting/fibrinolysis (fibrinogen and PAI-1) are significantly associated with subsequent development of kidney dysfunction. Although some markers showed variations in the associations between the follow-up windows examined, the results indicate that biomarkers (sTNFR-1/2, sE-selectin, PAI-1, and fibrinogen) are associated with progression to chronic kidney disease in both the 3-year and the 10-year windows. Plasma markers of inflammation, endothelial dysfunction, and clotting/fibrinolysis are associated with progression to kidney dysfunction in type 1 diabetes during both short-term and long-term follow-up. © 2017 by the American Diabetes Association.

  3. Characterization of an Isolated Kidney's Vasculature for Use in Bio-Thermal Modeling

    Science.gov (United States)

    Payne, Allison H.; Parker, Dennis L.; Moellmer, Jeff; Roemer, Robert B.; Clifford, Sarah

    2007-05-01

    Accurate bio-thermal modeling requires site-specific modeling of discrete vascular anatomy. Presented herewith are several steps that have been developed to describe the vessel network of isolated canine and bovine kidneys. These perfused, isolated kidneys provide an environment to repeatedly test and improve acquisition methods to visualize the vascular anatomy, as well as providing a method to experimentally validate discrete vasculature thermal models. The organs are preserved using a previously developed methodology that keeps the vasculature intact, allowing for the organ to be perfused. It also allows for the repeated fixation and re-hydration of the same organ, permitting the comparison of various methods and models. The organ extraction, alcohol preservation, and perfusion of the organ are described. The vessel locations were obtained through a high-resolution time-of-flight (TOF) magnetic resonance angiography (MRA) technique. Sequential improvements of both the experimental setup used for this acquisition, as well as MR sequence development are presented. The improvements in MR acquisition and experimental setup improved the number of vessels seen in both the raw data and segmented images by 50%. An automatic vessel centerline extraction algorithm describes both vessel location and genealogy. Centerline descriptions also allows for vessel diameter and flow rate determination, providing valuable input parameters for the discrete vascular thermal model. Characterized vessels networks of both canine and bovine kidneys are presented. While these tools have been developed in an ex vivo environment, all steps can be applied to in vivo applications.

  4. Virus-Clip: a fast and memory-efficient viral integration site detection tool at single-base resolution with annotation capability.

    Science.gov (United States)

    Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L

    2015-08-28

    Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.

  5. Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-time Haptic Feedback

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J.; Bailey, Daniel P.; Elsenousi, Abdussalam; Roitberg, Ben Z.; Bernardo, Antonio; Banerjee, P. Pat; Charbel, Fady T.

    2014-01-01

    Background With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. Objective To develop and evaluate the usefulness of a new haptic-based virtual reality (VR) simulator in the training of neurosurgical residents. Methods A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the Immersive Touch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomography angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-D immersive VR environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from three residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Results Residents felt that the simulation would be useful in preparing for real-life surgery. About two thirds of the residents felt that the 3-D immersive anatomical details provided a very close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They believed the simulation is useful for preoperative surgical rehearsal and neurosurgical training. One third of the residents felt that the technology in its current form provided very realistic haptic feedback for aneurysm surgery. Conclusion Neurosurgical residents felt that the novel immersive VR simulator is helpful in their training especially since they do not get a chance to perform aneurysm clippings until very late in their residency programs. PMID:25599200

  6. [Choledochal lithiasis and stenosis secondary to the migration of a surgical clip].

    Science.gov (United States)

    Baldomà España, M; Pernas Canadell, J C; González Ceballos, S

    2014-01-01

    The migration of a clip to the common bile duct after cholecystectomy is an uncommon, usually late, complication that can lead to diverse complications like stone formation, stenosis, and obstruction in the bile duct. We present the case of a patient who presented with signs and symptoms of cholangitis due to clip migration one year after laparoscopic cholecystectomy; endoscopic retrograde cholangiopancreatography and biliary tract stent placement resolved the problem. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  7. Hemoglobin A1c Levels Predicts Acute Kidney Injury after Coronary Artery Bypass Surgery in Non-Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Cevdet Ugur Kocogulları

    Full Text Available Abstract INTRODUCTION: Elevated hemoglobin A1c levels in patients with diabetes mellitus have been known as a risk factor for acute kidney injury after coronary artery bypass grafting. However, the relationship between hemoglobin A1c levels in non-diabetics and acute kidney injury is under debate. We aimed to investigate the association of preoperative hemoglobin A1c levels with acute kidney injury in non-diabetic patients undergoing isolated coronary artery bypass grafting. METHODS: 202 non-diabetic patients with normal renal function (serum creatinine <1.4 mg/dl who underwent isolated coronary bypass were analyzed. Hemoglobin A1c level was measured at the baseline examination. Patients were separated into two groups according to preoperative Hemoglobin A1c level. Group 1 consisted of patients with preoperative HbA1c levels of < 5.6% and Group 2 consisted of patients with preoperative HbA1c levels of ≥ 5.6%. Acute kidney injury diagnosis was made by comparing baseline and postoperative serum creatinine to determine the presence of predefined significant change based on the Kidney Disease Improving Global Outcomes (KDIGO definition. RESULTS: Acute kidney injury occurred in 19 (10.5% patients after surgery. The incidence of acute kidney injury was 3.6% in Group 1 and 16.7% in Group 2. Elevated baseline hemoglobin A1c level was found to be associated with acute kidney injury (P=0.0001. None of the patients became hemodialysis dependent. The cut off value for acute kidney injury in our group of patients was 5.75%. CONCLUSION: Our findings suggest that, in non-diabetics, elevated preoperative hemoglobin A1c level may be associated with acute kidney injury in patients undergoing coronary artery bypass grafting. Prospective randomized studies in larger groups are needed to confirm these results.

  8. Origin of fin-clipped salmonids collected at two thermal discharges on Lake Michigan

    International Nuclear Information System (INIS)

    Romberg, G.P.; Thommes, M.M.; Spigarelli, S.A.

    1974-01-01

    Fin clips observed on fish collected during tagging studies at the Point Beach and Waukegan thermal discharges were recorded and the data were tabulated by species. Using fin clip and fish size, attempts were made to identify probable stocking locations and dates from agency records. Data are presented for lake trout, rainbow trout, brown trout, and Coho salmon. Tables are presented to show probable stocking locations and dates

  9. BioClips of symmetric and asymmetric cell division.

    Science.gov (United States)

    Lu, Fong-Mei; Eliceiri, Kevin W; White, John G

    2007-05-01

    Animations have long been used as tools to illustrate complex processes in such diverse fields as mechanical engineering, astronomy, bacteriology and physics. Animations in biology hold particular educational promise for depicting complex dynamic processes, such as photosynthesis, motility, viral replication and cellular respiration, which cannot be easily explained using static two-dimensional images. However, these animations have often been restrictive in scope, having been created for a specific classroom or research audience. In recent years, a new type of animation has emerged called the BioClip (http://www.bioclips.com) that strives to present science in an interactive multimedia format, which is, at once, informative and entertaining, by combining animations, text descriptions and music in one portable cross-platform document. In the present article, we illustrate the educational value of this new electronic resource by reviewing in depth two BioClips our group has created which describe the processes of symmetric and asymmetric cell division (http://www.wormclassroom.org/cb/bioclip).

  10. Sodium-Glucose Linked Cotransporter-2 Inhibition Does Not Attenuate Disease Progression in the Rat Remnant Kidney Model of Chronic Kidney Disease.

    Directory of Open Access Journals (Sweden)

    Yanling Zhang

    Full Text Available Pharmacological inhibition of the proximal tubular sodium-glucose linked cotransporter-2 (SGLT2 leads to glycosuria in both diabetic and non-diabetic settings. As a consequence of their ability to modulate tubuloglomerular feedback, SGLT2 inhibitors, like agents that block the renin-angiotensin system, reduce intraglomerular pressure and single nephron GFR, potentially affording renoprotection. To examine this further we administered the SGLT2 inhibitor, dapagliflozin, to 5/6 (subtotally nephrectomised rats, a model of progressive chronic kidney disease (CKD that like CKD in humans is characterised by single nephron hyperfiltration and intraglomerular hypertension and where angiotensin converting enzyme inhibitors and angiotensin receptor blockers are demonstrably beneficial. When compared with untreated rats, both sham surgery and 5/6 nephrectomised rats that had received dapagliflozin experienced substantial glycosuria. Nephrectomised rats developed hypertension, heavy proteinuria and declining GFR that was unaffected by the administration of dapagliflozin. Similarly, SGLT2 inhibition did not attenuate the extent of glomerulosclerosis, tubulointerstitial fibrosis or overexpression of the profibrotic cytokine, transforming growth factor-ß1 mRNA in the kidneys of 5/6 nephrectomised rats. While not precluding beneficial effects in the diabetic setting, these findings indicate that SGLT2 inhibition does not have renoprotective effects in this classical model of progressive non-diabetic CKD.

  11. Effects of Tail Clipping on Larval Performance and Tail Regeneration Rates in the Near Eastern Fire Salamander, Salamandra infraimmaculata.

    Directory of Open Access Journals (Sweden)

    Ori Segev

    Full Text Available Tail-tip clipping is a common technique for collecting tissue samples from amphibian larvae and adults. Surprisingly, studies of this invasive sampling procedure or of natural tail clipping--i.e., bites inflicted by predators including conspecifics--on the performance and fitness of aquatic larval stages of urodeles are scarce. We conducted two studies in which we assessed the effects of posterior tail clipping (~30 percent of tail on Near Eastern fire salamander (Salamandra infraimmaculata larvae. In a laboratory study, we checked regeneration rates of posterior tail-tip clipping at different ages. Regeneration rates were hump-shaped, peaking at the age of ~30 days and then decreasing. This variation in tail regeneration rates suggests tradeoffs in resource allocation between regeneration and somatic growth during early and advanced development. In an outdoor artificial pond experiment, under constant larval densities, we assessed how tail clipping of newborn larvae affects survival to, time to, and size at metamorphosis. Repeated measures ANOVA on mean larval survival per pond revealed no effect of tail clipping. Tail clipping had correspondingly no effect on larval growth and development expressed in size (mass and snout-vent length at, and time to, metamorphosis. We conclude that despite the given variation in tail regeneration rates throughout larval ontogeny, clipping of 30% percent of the posterior tail area seems to have no adverse effects on larval fitness and survival. We suggest that future use of this imperative tool for the study of amphibian should take into account larval developmental stage during the time of application and not just the relative size of the clipped tail sample.

  12. Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.

    Science.gov (United States)

    Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R

    2014-06-01

    We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.

  13. Contribution of stone size to chronic kidney disease in kidney stone formers.

    Science.gov (United States)

    Ahmadi, Farrokhlagha; Etemadi, Samira Motedayen; Lessan-Pezeshki, Mahbob; Mahdavi-Mazdeh, Mitra; Ayati, Mohsen; Mir, Alireza; Yazdi, Hadi Rokni

    2015-01-01

    To determine whether stone burden correlates with the degree of chronic kidney disease in kidney stone formers. A total of 97 extracorporeal shockwave lithotripsy candidates aged 18 years and older were included. Size, number and location of the kidney stones, along with cumulative stone size, defined as the sum of diameters of all stones) were determined. Estimated glomerular filtration rate was determined using the Chronic Kidney Disease Epidemiology Collaboration cystatin C/creatinine equation, and chronic kidney disease was defined as estimated glomerular filtration rate chronic kidney disease. The relationship persisted even after adjustment for age, sex, body mass index, C-reactive protein, fasting plasma glucose, thyroid stimulating hormone, presence of microalbuminuria, history of renal calculi, history of extracorporeal shockwave lithotripsy, number and location of the stones (odds ratio 1.24, 95% confidence interval 1.02-1.52). The same was not observed for individuals with a cumulative stone size ≥ 20 mm. In kidney stone formers with a cumulative stone size up to 20 mm, estimated glomerular filtration rate linearly declines with increasing cumulative stone size. Additionally, cumulative stone size is an independent predictor of chronic kidney disease in this group of patients. © 2014 The Japanese Urological Association.

  14. Human kidney anion exchanger 1 interacts with kinesin family member 3B (KIF3B)

    Energy Technology Data Exchange (ETDEWEB)

    Duangtum, Natapol [Medical Molecular Biology Unit, Office for Research and Development Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Department of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Junking, Mutita; Sawasdee, Nunghathai [Medical Molecular Biology Unit, Office for Research and Development Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Cheunsuchon, Boonyarit [Department of Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Limjindaporn, Thawornchai, E-mail: limjindaporn@yahoo.com [Department of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand); Yenchitsomanus, Pa-thai, E-mail: grpye@mahidol.ac.th [Medical Molecular Biology Unit, Office for Research and Development Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700 (Thailand)

    2011-09-16

    Highlights: {yields} Impaired trafficking of kAE1 causes distal renal tubular acidosis (dRTA). {yields} The interaction between kAE1 and kinesin family member 3B (KIF3B) is reported. {yields} The co-localization between kAE and KIF3B was detected in human kidney tissues. {yields} A marked reduction of kAE1 on the cell membrane was observed when KIF3B was knockdown. {yields} KFI3B plays an important role in trafficking of kAE1 to the plasma membrane. -- Abstract: Impaired trafficking of human kidney anion exchanger 1 (kAE1) to the basolateral membrane of {alpha}-intercalated cells of the kidney collecting duct leads to the defect of the Cl{sup -}/HCO{sub 3}{sup -} exchange and the failure of proton (H{sup +}) secretion at the apical membrane of these cells, causing distal renal tubular acidosis (dRTA). In the sorting process, kAE1 interacts with AP-1 mu1A, a subunit of AP-1A adaptor complex. However, it is not known whether kAE1 interacts with motor proteins in its trafficking process to the plasma membrane or not. We report here that kAE1 interacts with kinesin family member 3B (KIF3B) in kidney cells and a dileucine motif at the carboxyl terminus of kAE1 contributes to this interaction. We have also demonstrated that kAE1 co-localizes with KIF3B in human kidney tissues and the suppression of endogenous KIF3B in HEK293T cells by small interfering RNA (siRNA) decreases membrane localization of kAE1 but increases its intracellular accumulation. All results suggest that KIF3B is involved in the trafficking of kAE1 to the plasma membrane of human kidney {alpha}-intercalated cells.

  15. Human kidney anion exchanger 1 interacts with kinesin family member 3B (KIF3B)

    International Nuclear Information System (INIS)

    Duangtum, Natapol; Junking, Mutita; Sawasdee, Nunghathai; Cheunsuchon, Boonyarit; Limjindaporn, Thawornchai; Yenchitsomanus, Pa-thai

    2011-01-01

    Highlights: → Impaired trafficking of kAE1 causes distal renal tubular acidosis (dRTA). → The interaction between kAE1 and kinesin family member 3B (KIF3B) is reported. → The co-localization between kAE and KIF3B was detected in human kidney tissues. → A marked reduction of kAE1 on the cell membrane was observed when KIF3B was knockdown. → KFI3B plays an important role in trafficking of kAE1 to the plasma membrane. -- Abstract: Impaired trafficking of human kidney anion exchanger 1 (kAE1) to the basolateral membrane of α-intercalated cells of the kidney collecting duct leads to the defect of the Cl - /HCO 3 - exchange and the failure of proton (H + ) secretion at the apical membrane of these cells, causing distal renal tubular acidosis (dRTA). In the sorting process, kAE1 interacts with AP-1 mu1A, a subunit of AP-1A adaptor complex. However, it is not known whether kAE1 interacts with motor proteins in its trafficking process to the plasma membrane or not. We report here that kAE1 interacts with kinesin family member 3B (KIF3B) in kidney cells and a dileucine motif at the carboxyl terminus of kAE1 contributes to this interaction. We have also demonstrated that kAE1 co-localizes with KIF3B in human kidney tissues and the suppression of endogenous KIF3B in HEK293T cells by small interfering RNA (siRNA) decreases membrane localization of kAE1 but increases its intracellular accumulation. All results suggest that KIF3B is involved in the trafficking of kAE1 to the plasma membrane of human kidney α-intercalated cells.

  16. HLA AND CROSS·REACTIVE ANTIGEN GROUP MATCHING FOR CADAVER KIDNEY ALLOCATION1

    Science.gov (United States)

    Starzl, Thomas E.; Eliasziw, Michael; Gjertson, David; Terasaki, Paul I.; Fung, John J.; Trucco, Massimo; Martell, Joan; McMichael, John; Scantlebury, Velma; Shapiro, Ron; Donner, Allan

    2010-01-01

    Background Allocation of cadaver kidneys by graded human leukocyte antigen (HLA) compatibility scoring arguably has had little effect on overall survival while prejudicing the transplant candidacy of African-American and other hard to match populations. Consequently, matching has been proposed of deduced amino acid residues of the individual HLA molecules shared by cross-reactive antigen groups (CREGs). We have examined the circumstances under which compatibility with either method impacted graft survival. Methods Using Cox proportional hazards regression modeling, we studied the relationship between levels of conventional HLA mismatch and other donor and recipient factors on primary cadaver kidney survival between 1981 and 1995 at the University of Pittsburgh (n=1,780) and in the United Network for Organ Sharing (UNOS) Scientific Registry during 1991–1995 (n=31,291). The results were compared with those obtained by the matching of amino acid residues that identified CREG-compatible cases with as many as four (but not five and six) HLA mismatches. Results With more than one HLA mismatch (>85% of patients in both series), most of the survival advantage of a zero mismatch was lost. None of the HLA loci were “weak.” In the UNOS (but not Pittsburgh) category of one-HLA mismatch (n=1334), a subgroup of CREG-matched recipients (35.3%) had better graft survival than the remaining 64.7%, who were CREG-mismatched. There was no advantage of a CREG match in the two- to four-HLA incompatibility tiers. Better graft survival with tacrolimus was observed in both the Pittsburgh and UNOS series. Conclusions Obligatory national sharing of cadaver kidneys is justifiable only for zero-HLA-mismatched kidneys. The potential value of CREG matching observed in the one-HLA-mismatched recipients of the UNOS (but not the Pittsburgh) experience deserves further study. PMID:9381546

  17. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Science.gov (United States)

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2011-01-01

    Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. © 2011 Carvalho et al.

  18. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Directory of Open Access Journals (Sweden)

    Sandra Carvalho

    Full Text Available Some authors have speculated that the cognitive component (P3 of the Event-Related Potential (ERP can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder.

  19. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  20. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    Science.gov (United States)

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. Glutathione peroxidase-1 gene (GPX1) variants, oxidative stress and risk of kidney complications in people with type 1 diabetes.

    Science.gov (United States)

    Mohammedi, Kamel; Patente, Thiago A; Bellili-Muñoz, Naima; Driss, Fathi; Le Nagard, Hervé; Fumeron, Frédéric; Roussel, Ronan; Hadjadj, Samy; Corrêa-Giannella, Maria Lúcia; Marre, Michel; Velho, Gilberto

    2016-02-01

    Glutathione peroxidase (GPX) is a class of antioxidant enzymes that catalyze the reduction of hydrogen peroxide to water. GPX1 is the most abundant isoform and is expressed in all kidney cells. Isoprostane and advanced oxidation protein products (AOPP) were identified as markers of oxidative stress in patients with kidney disease. We investigated associations of GPX1 genotypes with kidney complications, and with plasma concentrations of isoprostane and AOPP in type 1 diabetic patients. Four SNPs in the GPX1 gene region were genotyped in SURGENE (n=340; 10-year follow-up); GENEDIAB (n=461) and GENESIS (n=584) cohorts of type 1 diabetic patients. Subsets of GENEDIAB (n=237) and GENESIS (n=466) participants were followed up for 9 and 5years, respectively. Plasma concentrations of isoprostane and AOPP were measured at baseline in GENEDIAB. Hazard ratios (HR) were estimated for incidence of kidney complications. In SURGENE, 98 renal events (new cases of microalbuminuria or progression to more severe stage of diabetic nephropathy) occurred during follow-up. The minor T-allele of rs3448 was associated with the incidence of renal events (HR 1.81, 95% CI 1.16-2.84, p=0.008). In GENESIS/GENEDIAB pooled study, end stage renal disease (ESRD) occurred during follow-up in 52 individuals. The same variant was associated with the incidence of ESRD (HR 3.34, 95% CI, 1.69-6.98, p=0.0004). The variant was also associated with higher plasma isoprostane concentration in GENEDIAB cohort: 2.02±0.12 (TT+CT) vs 1.75±0.13 (CC) ng/mL (p=0.009), and with higher plasma AOPP in the subset of participants with the baseline history of ESRD (TT+CT 67±6 vs CC 48±6μmol/L, p=0.006). The minor T-allele of rs3448 was associated with kidney complications (incidences of microalbuminuria, renal events and ESRD) in patients with type 1 diabetes. The risk allele was associated with higher plasma concentrations of isoprostane and AOPP. Our results are consistent with the implication of GPX1 in the

  2. Development and application of a rat PBPK model to elucidate kidney and liver effects induced by ETBE and tert-butanol

    International Nuclear Information System (INIS)

    Salazar, Keith D.; Brinkerhoff, Christopher J.; Lee, Janice S.; Chiu, Weihsueh A.

    2015-01-01

    Subchronic and chronic studies in rats of the gasoline oxygenates ethyl tert-butyl ether (ETBE) and tert-butanol (TBA) report similar noncancer kidney and liver effects but differing results with respect to kidney and liver tumors. Because TBA is a major metabolite of ETBE, it is possible that TBA is the active toxic moiety in all these studies, with reported differences due simply to differences in the internal dose. To test this hypothesis, a physiologically-based pharmacokinetic (PBPK) model was developed for ETBE and TBA to calculate internal dosimetrics of TBA following either TBA or ETBE exposure. This model, based on earlier PBPK models of methyl tert-butyl ether (MTBE), was used to evaluate whether kidney and liver effects are consistent across routes of exposure, as well as between ETBE and TBA studies, on the basis of estimated internal dose. The results demonstrate that noncancer kidney effects, including kidney weight changes, urothelial hyperplasia, and chronic progressive nephropathy (CPN), yielded consistent dose–response relationships across routes of exposure and across ETBE and TBA studies using TBA blood concentration as the dose metric. Relative liver weights were also consistent across studies on the basis of TBA metabolism, which is proportional to TBA liver concentrations. However, kidney and liver tumors were not consistent using any dose metric. These results support the hypothesis that TBA mediates the noncancer kidney and liver effects following ETBE administration; however, additional factors besides internal dose are necessary to explain the induction of liver and kidney tumors. - Highlights: • We model two metabolically-related fuel oxygenates to address toxicity data gaps. • Kidney and liver effects are compared on an internal dose basis. • Noncancer kidney effects are consistent using TBA blood concentration. • Liver weight changes are consistent using TBA metabolic rate. • Kidney and liver tumors are not consistent using

  3. Development and application of a rat PBPK model to elucidate kidney and liver effects induced by ETBE and tert-butanol

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Keith D., E-mail: Salazar.keith@epa.gov [Toxicity Pathways Branch, IRIS Division, NCEA, ORD, US EPA, Washington, DC 20460 (United States); Brinkerhoff, Christopher J., E-mail: Brinkerhoff.Chris@epa.gov [Risk Assessment Division, OPPT, OCSPP, US EPA, Washington, DC 20460 (United States); Lee, Janice S., E-mail: Lee.JaniceS@epa.gov [Toxicity Pathways Branch, IRIS Division, NCEA, ORD, US EPA, Washington, DC 20460 (United States); Chiu, Weihsueh A., E-mail: wchiu@cvm.tamu.edu [Department of Veterinary Integrative Biosciences, College of Veterinary Medicine and Biomedical Sciences, Texas A& M University, College Station, TX 77843 (United States)

    2015-11-01

    Subchronic and chronic studies in rats of the gasoline oxygenates ethyl tert-butyl ether (ETBE) and tert-butanol (TBA) report similar noncancer kidney and liver effects but differing results with respect to kidney and liver tumors. Because TBA is a major metabolite of ETBE, it is possible that TBA is the active toxic moiety in all these studies, with reported differences due simply to differences in the internal dose. To test this hypothesis, a physiologically-based pharmacokinetic (PBPK) model was developed for ETBE and TBA to calculate internal dosimetrics of TBA following either TBA or ETBE exposure. This model, based on earlier PBPK models of methyl tert-butyl ether (MTBE), was used to evaluate whether kidney and liver effects are consistent across routes of exposure, as well as between ETBE and TBA studies, on the basis of estimated internal dose. The results demonstrate that noncancer kidney effects, including kidney weight changes, urothelial hyperplasia, and chronic progressive nephropathy (CPN), yielded consistent dose–response relationships across routes of exposure and across ETBE and TBA studies using TBA blood concentration as the dose metric. Relative liver weights were also consistent across studies on the basis of TBA metabolism, which is proportional to TBA liver concentrations. However, kidney and liver tumors were not consistent using any dose metric. These results support the hypothesis that TBA mediates the noncancer kidney and liver effects following ETBE administration; however, additional factors besides internal dose are necessary to explain the induction of liver and kidney tumors. - Highlights: • We model two metabolically-related fuel oxygenates to address toxicity data gaps. • Kidney and liver effects are compared on an internal dose basis. • Noncancer kidney effects are consistent using TBA blood concentration. • Liver weight changes are consistent using TBA metabolic rate. • Kidney and liver tumors are not consistent using

  4. Liraglutide Reduces Both Atherosclerosis and Kidney Inflammation in Moderately Uremic LDLr-/- Mice.

    Directory of Open Access Journals (Sweden)

    Line S Bisgaard

    Full Text Available Chronic kidney disease (CKD leads to uremia. CKD is characterized by a gradual increase in kidney fibrosis and loss of kidney function, which is associated with a progressive increase in risk of atherosclerosis and cardiovascular death. To prevent progression of both kidney fibrosis and atherosclerosis in uremic settings, insight into new treatment options with effects on both parameters is warranted. The GLP-1 analogue liraglutide improves glucose homeostasis, and is approved for treatment of type 2 diabetes. Animal studies suggest that GLP-1 also dampens inflammation and atherosclerosis. Our aim was to examine effects of liraglutide on kidney fibrosis and atherosclerosis in a mouse model of moderate uremia (5/6 nephrectomy (NX. Uremic (n = 29 and sham-operated (n = 14 atherosclerosis-prone low density lipoprotein receptor knockout mice were treated with liraglutide (1000 μg/kg, s.c. once daily or vehicle for 13 weeks. As expected, uremia increased aortic atherosclerosis. In the remnant kidneys from NX mice, flow cytometry revealed an increase in the number of monocyte-like cells (CD68+F4/80-, CD4+, and CD8+ T-cells, suggesting that moderate uremia induced kidney inflammation. Furthermore, markers of fibrosis (i.e. Col1a1 and Col3a1 were upregulated, and histological examinations showed increased glomerular diameter in NX mice. Importantly, liraglutide treatment attenuated atherosclerosis (~40%, p < 0.05 and reduced kidney inflammation in NX mice. There was no effect of liraglutide on expression of fibrosis markers and/or kidney histology. This study suggests that liraglutide has beneficial effects in a mouse model of moderate uremia by reducing atherosclerosis and attenuating kidney inflammation.

  5. Unilateral Renal Ischemia as a Model of Acute Kidney Injury and Renal Fibrosis in Cats.

    Science.gov (United States)

    Schmiedt, C W; Brainard, B M; Hinson, W; Brown, S A; Brown, C A

    2016-01-01

    The objectives of this study were to define the acute and chronic effects of 1-hour unilateral in vivo renal ischemia on renal function and histology in cats. Twenty-one adult purpose-bred research cats were anesthetized, and 1 kidney underwent renal artery and vein occlusion for 1 hour. Serum creatinine and urea concentrations, urine protein:creatinine ratio, urine-specific gravity, glomerular filtration rate, hematocrit, platelet concentration and function, and white blood cell count were measured at baseline and variable time points after ischemia. Renal histopathology was evaluated on days 3, 6, 12, 21, 42, and 70 postischemia; changes in smooth muscle actin and interstitial collagen were examined. Following ischemia, whole animal glomerular filtration rate was significantly reduced (57% of baseline on day 6; P < .05). At the early time points, the ischemic kidneys exhibited severe acute epithelial necrosis accompanied by evidence of regeneration of tubules predominantly within the corticomedullary junction. At later periods, postischemic kidneys had evidence of tubular atrophy and interstitial inflammation with significantly more smooth muscle actin and interstitial collagen staining and interstitial fibrosis when compared with the contralateral control kidneys. This study characterizes the course of ischemic acute kidney injury in cats and demonstrates that ischemic acute kidney injury triggers chronic fibrosis, interstitial inflammation, and tubular atrophy in feline kidneys. These late changes are typical of those observed in cats with naturally occurring chronic kidney disease. © The Author(s) 2015.

  6. Optical coherence tomography and computer-aided diagnosis of a murine model of chronic kidney disease

    Science.gov (United States)

    Wang, Bohan; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Tang, Qinggong; Wu, Tongtong; Falola, Reuben; Smith, Tikina; Andrews, Peter M.; Chen, Yu

    2017-12-01

    Chronic kidney disease (CKD) is characterized by a progressive loss of renal function over time. Histopathological analysis of the condition of glomeruli and the proximal convolutional tubules over time can provide valuable insights into the progression of CKD. Optical coherence tomography (OCT) is a technology that can analyze the microscopic structures of a kidney in a nondestructive manner. Recently, we have shown that OCT can provide real-time imaging of kidney microstructures in vivo without administering exogenous contrast agents. A murine model of CKD induced by intravenous Adriamycin (ADR) injection is evaluated by OCT. OCT images of the rat kidneys have been captured every week up to eight weeks. Tubular diameter and hypertrophic tubule population of the kidneys at multiple time points after ADR injection have been evaluated through a fully automated computer-vision system. Results revealed that mean tubular diameter and hypertrophic tubule population increase with time in post-ADR injection period. The results suggest that OCT images of the kidney contain abundant information about kidney histopathology. Fully automated computer-aided diagnosis based on OCT has the potential for clinical evaluation of CKD conditions.

  7. CKD in diabetes: diabetic kidney disease versus nondiabetic kidney disease.

    Science.gov (United States)

    Anders, Hans-Joachim; Huber, Tobias B; Isermann, Berend; Schiffer, Mario

    2018-06-01

    The increasing global prevalence of type 2 diabetes mellitus (T2DM) and chronic kidney disease (CKD) has prompted research efforts to tackle the growing epidemic of diabetic kidney disease (DKD; also known as diabetic nephropathy). The limited success of much of this research might in part be due to the fact that not all patients diagnosed with DKD have renal dysfunction as a consequence of their diabetes mellitus. Patients who present with CKD and diabetes mellitus (type 1 or type 2) can have true DKD (wherein CKD is a direct consequence of their diabetes status), nondiabetic kidney disease (NDKD) coincident with diabetes mellitus, or a combination of both DKD and NDKD. Preclinical studies using models that more accurately mimic these three entities might improve the ability of animal models to predict clinical trial outcomes. Moreover, improved insights into the pathomechanisms that are shared by these entities - including sodium-glucose cotransporter 2 (SGLT2) and renin-angiotensin system-driven glomerular hyperfiltration and tubular hyper-reabsorption - as well as those that are unique to individual entities might lead to the identification of new treatment targets. Acknowledging that the clinical entity of CKD plus diabetes mellitus encompasses NDKD as well as DKD could help solve some of the urgent unmet medical needs of patients affected by these conditions.

  8. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  9. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  10. New insights into potential functions for the protein 4.1superfamily of proteins in kidney epithelium

    Energy Technology Data Exchange (ETDEWEB)

    Calinisan, Venice; Gravem, Dana; Chen, Ray Ping-Hsu; Brittin,Sachi; Mohandas, Narla; Lecomte, Marie-Christine; Gascard, Philippe

    2005-06-17

    Members of the protein 4.1 family of adapter proteins are expressed in a broad panel of tissues including various epithelia where they likely play an important role in maintenance of cell architecture and polarity and in control of cell proliferation. We have recently characterized the structure and distribution of three members of the protein 4.1 family, 4.1B, 4.1R and 4.1N, in mouse kidney. We describe here binding partners for renal 4.1 proteins, identified through the screening of a rat kidney yeast two-hybrid system cDNA library. The identification of putative protein 4.1-based complexes enables us to envision potential functions for 4.1 proteins in kidney: organization of signaling complexes, response to osmotic stress, protein trafficking, and control of cell proliferation. We discuss the relevance of these protein 4.1-based interactions in kidney physio-pathology in the context of their previously identified functions in other cells and tissues. Specifically, we will focus on renal 4.1 protein interactions with beta amyloid precursor protein (beta-APP), 14-3-3 proteins, and the cell swelling-activated chloride channel pICln. We also discuss the functional relevance of another member of the protein 4.1 superfamily, ezrin, in kidney physiopathology.

  11. Patterns and Meanings of English Words through Word Formation Processes of Acronyms, Clipping, Compound and Blending Found in Internet-Based Media

    Directory of Open Access Journals (Sweden)

    Rio Rini Diah Moehkardi

    2017-02-01

    Full Text Available This research aims to explore the word-formation process in English new words found in the internet-based media through acronym, compound,  clipping and blending and their meanings. This study applies Plag’s (2002 framework of acronym and compound; Jamet’s (2009 framework of clipping, and Algeo’s framework (1977 in Hosseinzadeh  (2014 for blending. Despite the  formula established in each respective framework,  there could be occurrences  of novelty and modification on how words are formed and  how meaning developed in  the newly formed words. The research shows that well accepted acronyms can become real words by taking lower case and affixation. Some acronyms initialized non-lexical words, used non initial letters, and used letters and numbers that pronounced the same with the words they represent. Compounding also includes numbers as the element member of the compound. The nominal nouns are likely to have metaphorical and idiomatic meanings. Some compounds evolve to new and more specific meaning. The study also finds that back-clipping is the most dominant clipping. In blending, the sub-category clipping of blending, the study finds out that when clipping takes place, the non-head element is back-clipped and the head is fore-clipped.

  12. Sociolinguistic import of name-clipping among Omambala cultural ...

    African Journals Online (AJOL)

    This study examines the perceived but obvious manifestation of name-clipping among Omambala cultural zone of Anambra State. This situation has given rise to distortion of names and most often, to either mis-interpretation or complete loss of the original and full meanings of the names. This situation of misinterpretation is ...

  13. Using Film Clips to Teach Teen Pregnancy Prevention: "The Gloucester 18" at a Teen Summit

    Science.gov (United States)

    Herrman, Judith W.; Moore, Christopher C.; Anthony, Becky

    2012-01-01

    Teaching pregnancy prevention to large groups offers many challenges. This article describes the use of film clips, with guided discussion, to teach pregnancy prevention. In order to analyze the costs associated with teen pregnancy, a film clip discussion session based with the film "The Gloucester 18" was the keynote of a youth summit. The lesson…

  14. Correlation of Point Shear Wave Velocity and Kidney Function in Chronic Kidney Disease.

    Science.gov (United States)

    Grosu, Iulia; Bob, Flaviu; Sporea, Ioan; Popescu, Alina; Şirli, Roxana; Schiller, Adalbert

    2018-04-24

    Point shear wave elastography is a quantitative ultrasound-based imaging method used in the assessment of renal disease. Among point shear wave elastographic options, 2 techniques have been studied considerably: Virtual Touch quantification (VTQ; Siemens AG, Erlangen, Germany) and ElastPQ (EPQ; Philips Healthcare, Bothell, WA). Both rely on the tissue response to an acoustic beam generated by the ultrasound transducer. The data on renal VTQ are more extensive, whereas EPQ has been used less thus far in the assessment of the kidneys. This study aimed to evaluate the performance of EPQ in the kidney and compare it with VTQ. We studied 124 participants using EPQ: 22 with no renal disease and 102 with chronic kidney disease (CKD). Ninety-one were studied with both the EPQ and VTQ methods. We obtained 5 valid measurements in each kidney, expressed in meters per second. The mean kidney stiffness measurements ± SD obtained with EPQ in the healthy control group were as follows: right kidney, 1.23 ± 0.33 m/s; and left kidney, 1.26 ± 0.32 m/s (P = .6). In the patients with CKD (all stages), the mean kidney stiffness measurements obtained were significantly lower: right kidney, 1.09 ± 0.39 m/s; and left kidney, 1.04 ± 0.38 m/s (P = .4). We observed that, similar to VTQ, EPQ values decreased with CKD progression, based on analysis of variance results using different CKD stages. From a receiver operating characteristic curve analysis, the cutoff value for an estimated glomerular filtration rate of less than 45 mL/min was 1.24 m/s, and the value for an estimated glomerular filtration rate of less than 30 mL/min was 1.07 m/s. When using EPQ, the kidney shear wave velocity is decreased in patients with CKD, an observation similar to that obtained by using the VTQ method. © 2018 by the American Institute of Ultrasound in Medicine.

  15. O MONITORAMENTO DE NOTÍCIAS COMO FERRAMENTA PARA A INTELIGÊNCIA COMPETITIVATHE CLIPPING AS TOLL FOR COMPETITIVE INTELLIGENCE

    Directory of Open Access Journals (Sweden)

    Ariane Barbosa Lemos

    2011-07-01

    Full Text Available O artigo apresenta um diagnóstico do serviço de monitoramento de notícias (clipping. No estudo, foram investigados os processos de elaboração desse serviço por uma empresa especializada e sua utilização por parte de organizações dos setores de educação executiva, jurídico e entretenimento. Conclui que tanto a empresa clipadora quanto seus clientes consideram o clipping útil para o processo decisório e o serviço é visto de forma complementar a ação geral de inteligência competitiva das organizações. Palavras-chave inteligência competitiva, monitoramento ambiental, fontes de informação e monitoramento de notícias. Abstract The paper presents a diagnostic study about a clipping service. This study focused the development of the service provided by a specialized firm and its use by organizations operating in the executive education, legal and entertainment areas. It concludes that both the company and your customers consider clipping useful for decision making and the clipping is seen as complementary to general action of competitive intelligence organizations. Keywords competitive intelligence, environmental scanning, information source and clipping.

  16. Successful Dual Kidney Transplantation After Hypothermic Oxygenated Perfusion of Discarded Human Kidneys

    Science.gov (United States)

    Ravaioli, Matteo; De Pace, Vanessa; Comai, Giorgia; Busutti, Marco; Gaudio, Massimo Del; Amaduzzi, Annalisa; Cucchetti, Alessandro; Siniscalchi, Antonio; La Manna, Gaetano; D’Errico, Antonietta A.D.; Pinna, Antonio Daniele

    2017-01-01

    Patient: Female, 58 Final Diagnosis: Nephroangiosclerosis Symptoms: Renal failure Medication: — Clinical Procedure: Resuscitation of grafts by hypothermic oxygenated perfusion Specialty: Transplantology Objective: Challenging differential diagnosis Background: The recovery of discarded human kidneys has increased in recent years and impels to use of unconventional organ preservation strategies that improve graft function. We report the first case of human kidneys histologically discarded and transplanted after hypothermic oxygenated perfusion (HOPE). Case Report: Marginal kidneys from a 78-year-old woman with brain death were declined by Italian transplant centers due to biopsy score (right kidney: 6; left kidney: 7). We recovered and preserved both kidneys through HOPE and we revaluated their use for transplantation by means of perfusion parameters. The right kidney was perfused for 1 h 20 min and the left kidney for 2 h 30 min. During organ perfusion, the renal flow increased progressively. We observed an increase of 34% for the left kidney (median flow 52 ml/min) and 50% for the right kidney (median flow 24 ml/min). Both kidneys had low perfusate’s lactate levels. We used perfusion parameters as important determinants of the organ discard. Based on our previous organ perfusion experience, the increase of renal flow and the low level of lactate following 1 h of HOPE lead us to declare both kidneys as appropriate for dual kidney transplantation (DKT). No complications were reported during the transplant and in the post-transplant hospital stay. The recipient had immediate graft function and serum creatinine value of 0.95 mg/dL at 3 months post-transplant. Conclusions: HOPE provides added information in the organ selection process and may improve graft quality of marginal kidneys. PMID:28928357

  17. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming

    2013-04-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  18. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming; Wang, Wen Ping; Lé vy, Bruno L.; Liu, Yang

    2013-01-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  19. A nephron-based model of the kidneys for macro-to-micro α-particle dosimetry

    Science.gov (United States)

    Hobbs, Robert F.; Song, Hong; Huso, David L.; Sundel, Margaret H.; Sgouros, George

    2012-07-01

    Targeted α-particle therapy is a promising treatment modality for cancer. Due to the short path-length of α-particles, the potential efficacy and toxicity of these agents is best evaluated by microscale dosimetry calculations instead of whole-organ, absorbed fraction-based dosimetry. Yet time-integrated activity (TIA), the necessary input for dosimetry, can still only be quantified reliably at the organ or macroscopic level. We describe a nephron- and cellular-based kidney dosimetry model for α-particle radiopharmaceutical therapy, more suited to the short range and high linear energy transfer of α-particle emitters, which takes as input kidney or cortex TIA and through a macro to micro model-based methodology assigns TIA to micro-level kidney substructures. We apply a geometrical model to provide nephron-level S-values for a range of isotopes allowing for pre-clinical and clinical applications according to the medical internal radiation dosimetry (MIRD) schema. We assume that the relationship between whole-organ TIA and TIA apportioned to microscale substructures as measured in an appropriate pre-clinical mammalian model also applies to the human. In both, the pre-clinical and the human model, microscale substructures are described as a collection of simple geometrical shapes akin to those used in the Cristy-Eckerman phantoms for normal organs. Anatomical parameters are taken from the literature for a human model, while murine parameters are measured ex vivo. The murine histological slides also provide the data for volume of occupancy of the different compartments of the nephron in the kidney: glomerulus versus proximal tubule versus distal tubule. Monte Carlo simulations are run with activity placed in the different nephron compartments for several α-particle emitters currently under investigation in radiopharmaceutical therapy. The S-values were calculated for the α-emitters and their descendants between the different nephron compartments for both the

  20. A nephron-based model of the kidneys for macro-to-micro α-particle dosimetry

    International Nuclear Information System (INIS)

    Hobbs, Robert F; Song Hong; H Sundel, Margaret; Sgouros, George; Huso, David L

    2012-01-01

    Targeted α-particle therapy is a promising treatment modality for cancer. Due to the short path-length of α-particles, the potential efficacy and toxicity of these agents is best evaluated by microscale dosimetry calculations instead of whole-organ, absorbed fraction-based dosimetry. Yet time-integrated activity (TIA), the necessary input for dosimetry, can still only be quantified reliably at the organ or macroscopic level. We describe a nephron- and cellular-based kidney dosimetry model for α-particle radiopharmaceutical therapy, more suited to the short range and high linear energy transfer of α-particle emitters, which takes as input kidney or cortex TIA and through a macro to micro model-based methodology assigns TIA to micro-level kidney substructures. We apply a geometrical model to provide nephron-level S-values for a range of isotopes allowing for pre-clinical and clinical applications according to the medical internal radiation dosimetry (MIRD) schema. We assume that the relationship between whole-organ TIA and TIA apportioned to microscale substructures as measured in an appropriate pre-clinical mammalian model also applies to the human. In both, the pre-clinical and the human model, microscale substructures are described as a collection of simple geometrical shapes akin to those used in the Cristy–Eckerman phantoms for normal organs. Anatomical parameters are taken from the literature for a human model, while murine parameters are measured ex vivo. The murine histological slides also provide the data for volume of occupancy of the different compartments of the nephron in the kidney: glomerulus versus proximal tubule versus distal tubule. Monte Carlo simulations are run with activity placed in the different nephron compartments for several α-particle emitters currently under investigation in radiopharmaceutical therapy. The S-values were calculated for the α-emitters and their descendants between the different nephron compartments for both the

  1. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Science.gov (United States)

    2010-04-01

    ... and an external monitoring device by means of pinching skin tissue with a nonreusable clip. This... shall have an approved PMA or a declared completed PDP in effect before being placed in commercial...

  2. Direct mounted photovoltaic device with improved front clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle; Brown, Jr., Claude; Gaston, Ryan S; Hus, Michael; Langmaid, Joe A; Lesniak, Mike

    2013-11-05

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent (overlapping) photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  3. Direct mounted photovoltaic device with improved side clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle L; Brown, Jr., Claude; Eurich, Gerald K; Gaston, Ryan S; Hus, Michael

    2013-11-19

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  4. Development of a new detection device using a glass clip emitting infrared fluorescence for laparoscopic surgery of gastric cancer

    International Nuclear Information System (INIS)

    Inada, Shunko Albano; Mori, Kensaku; Fuchi, Shingo; Hasegawa, Junichi; Misawa, Kazunari; Nakanishi, Hayao

    2015-01-01

    In conventional method, to identify location of the tumor intraperitoneally for extirpation of the gastric cancer, charcoal ink is injected around the primary tumor. However, in the time of laparoscopic operation, it is difficult to estimate specific site of primary tumor. In this study we developed a glass phosphors was realized with Yb 3+ , Nd 3+ doped to Bi 2 O 3 -B 2 O 3 based glasses, which have central emission wavelength of 1020 nm and 100 nm of FWHM. Using this glass phosphor, we developed a fluorescent clip and the laparoscopic fluorescent detection system for clip-derived near-infrared light. To evaluated clinical performance of a fluorescent clip and the laparoscopic detection system, we used resected stomach from the patients. Fluorescent clip was fixed on the gastric mucosa, and an excitation light (wavelength: 808nm) was irradiated from outside of stomach for detection of fluorescent through stomach wall. As a result, fluorescent emission from the clip was successfully detected. These results indicate that the glass fluorescent clip in combination with laparoscopic detection system is a very useful method to identify the exact location of the primary gastric cancer. (paper)

  5. Early chronic kidney disease: diagnosis, management and models of care

    Science.gov (United States)

    Wouters, Olivier J.; O'Donoghue, Donal J.; Ritchie, James; Kanavos, Panos G.; Narva, Andrew S.

    2015-01-01

    Chronic kidney disease (CKD) is a prevalent condition in many countries, and it is estimated that over $1 trillion is spent globally on end-stage renal disease (ESRD) care. There is a clear clinical and economic rationale for designing timely and appropriate health system responses to limit progression from CKD to ESRD. This article reviews the gaps in our knowledge about which early CKD interventions are appropriate, the optimal time to intervene, and what model of care to adopt. The available diagnostic tests exhibit key limitations. Clinical care may improve if early-stage (1–3) CKD with risk for progression towards ESRD is differentiated from early CKD that is unlikely to advance. It is possible that CKD should be re-conceptualized as a part of primary care. Additional research is needed to better understand the risk factors for CKD progression. Systems modelling can be used to evaluate the impact of different care models on CKD outcomes and costs. The US Indian Health Service experience has demonstrated that an integrated, system-wide approach, even in an underfunded system, can produce significant benefits. PMID:26055354

  6. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  7. MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Krayenbühl, Niklaus; Sarnthein, Johannes; Oinas, Minna; Erdem, Eren; Krisht, Ali F

    2011-09-01

    During surgical clipping of intracranial aneurysms, reduction in SEP amplitude is thought to indicate cortical ischemia and subsequent neurological deficits. Since the sensitivity of SEP is questioned, we investigated SEP with respect to post-operative ischemia. In 36 patients with 51 intracranial aneurysms, clinical evaluation and diffusion-weighted MRI (DWI) was performed before and within 24h after surgery. During surgery, time of temporary occlusion was recorded. MRI images were reviewed for signs of ischemia. For 43 clip applications (84%), we observed neither pathologic SEP events nor ischemia in MRI. In two cases where reduction lasted >10 min after clip release, SEP events correlated with ischemia in the MRI. Only one of the ischemic patients was symptomatic and developed a transient hemiparesis. While pathologic SEP events correlated with visible ischemia in MRI only in two cases with late SEP recovery, ischemia in MRI may have been transient or may not have reached detection threshold in the other cases, in agreement with the absence of permanent neurological deficits. In complex aneurysm cases, where prolonged temporary occlusion is expected, SEP should be used to detect ischemia at a reversible stage to improve the safety of aneurysm clipping. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Custom-made different designs of pressure clips for the management of ear lobe keloids

    Directory of Open Access Journals (Sweden)

    Anshul Chugh

    2013-01-01

    Full Text Available Introduction : Keloids are frequent finding after physical trauma. Keloids of ear lobe are common complication of ear piercing, although its incidence remains unknown. The use of intrakeloid resection and a form pressure device to treat pinna keloids. The recommendation of this therapy is to maintain constant pressure and duration of pressure therapy was about 25 weeks. Clinical innovation : This article will present inexpensive custom made pressure clips of various designs. The dimensions of polymethylmethacrylate (PMMA plates in ear lobe clip presented by us though they esthetically not so good, but colored PMMA has been used to make it decorative and acceptable by most of the patients. This has been an encouraging experience to use the different designs. Discussion : Ear clip prosthesis has been developed for maintaining pressure on ear lobe keloids before and after surgical removal. The prosthesis includes an ear clip to which heat-polymerized acrylic resin is attached, which covers the keloid area. Pressure therapy is widely used to help in the early maturation of scar tissue and to prevent the recurrence of keloid. The preliminary report by Brent revealed that constant light pressure was an effective means of preventing post excision recurrence of ear lobe keloids using a decorative, spring-pressure earring.

  9. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements.

    Science.gov (United States)

    Carneiro, Grace Kelly Martins; Roque, Juliano Alves; Segundo, Aguinaldo Silva Garcez; Suzuki, Hideo

    2015-01-01

    The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip. Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip. The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle. Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  10. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Directory of Open Access Journals (Sweden)

    Grace Kelly Martins Carneiro

    2015-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20 were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000, after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811. There were significant differences on stiffness among the three types of brackets (p = 0.005. The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  11. Organoids: Modelling polycystic kidney disease

    Science.gov (United States)

    Romagnani, Paola

    2017-11-01

    Cysts were generated from organoids in vitro and the removal of adherent cues was shown to play a key role in polycystic kidney disease progression. These cysts resembled those of diseased tissue phenotypically and were capable of remodelling their microenvironment.

  12. A model-specific role of microRNA-223 as a mediator of kidney injury during experimental sepsis.

    Science.gov (United States)

    Colbert, James F; Ford, Joshay A; Haeger, Sarah M; Yang, Yimu; Dailey, Kyrie L; Allison, Kristen C; Neudecker, Viola; Evans, Christopher M; Richardson, Vanessa L; Brodsky, Kelley S; Faubel, Sarah; Eltzschig, Holger K; Schmidt, Eric P; Ginde, Adit A

    2017-08-01

    Sepsis outcomes are heavily dependent on the development of septic organ injury, but no interventions exist to interrupt or reverse this process. microRNA-223 (miR-223) is known to be involved in both inflammatory gene regulation and host-pathogen interactions key to the pathogenesis of sepsis. The goal of this study was to determine the role of miR-223 as a mediator of septic kidney injury. Using miR-223 knockout mice and multiple models of experimental sepsis, we found that miR-223 differentially influences acute kidney injury (AKI) based on the model used. In the absence of miR-223, mice demonstrated exaggerated AKI in sterile models of sepsis (LPS injection) and attenuated AKI in a live-infection model of sepsis (cecal ligation and puncture). We demonstrated that miR-223 expression is induced in kidney homogenate after cecal ligation and puncture, but not after LPS or fecal slurry injection. We investigated additional potential mechanistic explanations including differences in peritoneal bacterial clearance and host stool virulence. Our findings highlight the complex role of miR-223 in the pathogenesis of septic kidney injury, as well as the importance of differences in experimental sepsis models and their consequent translational applicability. Copyright © 2017 the American Physiological Society.

  13. Kidney function and mortality post-liver transplant in the Model for End-Stage Liver Disease era

    Directory of Open Access Journals (Sweden)

    Sethi A

    2011-11-01

    Full Text Available Aastha Sethi1, Michelle M Estrella1, Richard Ugarte2, Mohamed G Atta1 1Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD, USA; 2University of Maryland Medical Center, Department of Medicine, Baltimore, MD, USA Abstract: The Model for End-Stage Liver Disease (MELD score incorporates serum creatinine and was introduced to facilitate allocation of orthotopic liver transplantation (LT. The objective is to determine the impact of MELD and kidney function on all-cause mortality. Among LTs performed in a tertiary referral hospital between 1995 and 2009, 419 cases were studied. Cox proportional hazards models were constructed to estimate the hazard ratios (HR and 95% confidence intervals (CI for death. Over mean follow-ups of 8.4 and 3.1 years during the pre-MELD and MELD era, 57 and 63 deaths were observed, respectively. Those transplanted during the MELD era had a higher likelihood of hepatorenal syndrome (8% vs 2%, P < 0.01, lower kidney function (median estimated glomerular filtration rate [eGFR] 77.8 vs 92.6 mL/min/1.73 m2, P < 0.01, and more pretransplantation renal replacement therapy (RRT (5% vs 1%; P < 0.01. All-cause mortality risk was similar in the MELD vs the pre-MELD era (HR: 0.98, 95% CI: 0.58–1.65. The risk of death, however, was nearly 3-fold greater (95% CI: 1.14–6.60 among those requiring pre-transplant RRT. Similarly, eGFR < 60 mL/min/1.73 m2 post-transplant was associated with a 2.5-fold higher mortality (95% CI: 1.48–4.11. The study suggests that MELD implementation had no impact on all-cause mortality post-LT. However, the need for pre-transplant RRT and post-transplant kidney dysfunction was associated with a more than 2-fold greater risk of subsequent death. Keywords: eGFR, mortality, MELD, liver transplant

  14. Emotion Index of Cover Song Music Video Clips based on Facial Expression Recognition

    DEFF Research Database (Denmark)

    Kavallakis, George; Vidakis, Nikolaos; Triantafyllidis, Georgios

    2017-01-01

    This paper presents a scheme of creating an emotion index of cover song music video clips by recognizing and classifying facial expressions of the artist in the video. More specifically, it fuses effective and robust algorithms which are employed for expression recognition, along with the use...... of a neural network system using the features extracted by the SIFT algorithm. Also we support the need of this fusion of different expression recognition algorithms, because of the way that emotions are linked to facial expressions in music video clips....

  15. Clinical outcome of critically ill, not fully recompensated, patients undergoing MitraClip therapy

    DEFF Research Database (Denmark)

    Rudolph, Volker; Huntgeburth, Michael; von Bardeleben, Ralph Stephan

    2014-01-01

    AIMS: As periprocedural risk is low, MitraClip implantation is often performed in critically ill, not fully recompensated patients, who are in NYHA functional class IV at the time of the procedure, to accelerate convalescence. We herein sought to evaluate the procedural and 30-day outcome.......3%. CONCLUSION: MitraClip therapy is feasible and safe even in critically ill, not fully recompensated patients and leads to symptomatic improvement in over two-thirds of these patients; however, it is associated with an elevated 30-day mortality....

  16. Glycation in human fingernail clippings using ATR-FTIR spectrometry, a new marker for the diagnosis and monitoring of diabetes mellitus.

    Science.gov (United States)

    Coopman, Renaat; Van de Vyver, Thijs; Kishabongo, Antoine Sadiki; Katchunga, Philippe; Van Aken, Elisabeth H; Cikomola, Justin; Monteyne, Tinne; Speeckaert, Marijn M; Delanghe, Joris R

    2017-01-01

    Although HbA1c is a good diagnostic tool for diabetes, the precarity of the health system and the costs limit the use of this biomarker in developing countries. Fingernail clippings contain ±85% of keratins, which are prone to glycation. Nail keratin glycation may reflect the average glycemia over the last months. We explored if attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) can be used as a non-invasive tool for assessing glycation in diabetes. Using ATR-FTIR spectroscopy, glycation and deglycation experiments with fructosamine 3-kinase allowed to identify the spectrum that corresponds with keratin glycation in fingernail clippings. Clippings of 105 healthy subjects and 127 diabetics were subjected to the standardized ATR-FTIR spectroscopy method. In vitro glycation resulted in an increased absorption at 1047cm -1 . Following enzymatic deglycation, this peak diminished significantly, proving that the AUC between 970 and 1140cm -1 corresponded with glycated proteins. Within-run CV of the assay was 3%. Storage of nail clippings at 37°C for 2weeks did not significantly change results. In diabetics, glycated nail protein concentrations (median: 1.51μmol/g protein, IQR: 1.37-1.85μmol/g protein) were significantly higher than in the controls (median: 1.19μmol/g protein, IQR: 1.09-1.26μmol/g protein) (p<0.0001). ROC analysis yielded an AUC of 0.92 at a cut-off point of 1.28μmol/g nail (specificity: 82%; sensitivity: 90%). No correlation was observed between the glycated nail protein concentrations and HbA1c. Protein glycation analysis in fingernails with ATR-FTIR spectroscopy could be an alternative affordable technique for diagnosing and monitoring diabetes. As the test does not consume reagents, and the preanalytical phase is extremely robust, the test could be particularly useful in developing countries. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Top-down and Middle-down Protein Analysis Reveals that Intact and Clipped Human Histones Differ in Post-translational Modification Patterns

    DEFF Research Database (Denmark)

    Tvardovskiy, Andrey; Wrzesinski, Krzysztof; Sidoli, Simone

    2015-01-01

    Post-translational modifications (PTMs) of histone proteins play a fundamental role in regulation of DNA-templated processes. There is also growing evidence that proteolytic cleavage of histone N-terminal tails, known as histone clipping, influences nucleosome dynamics and functional properties...... hepatocytes and the hepatocellular carcinoma cell line HepG2/C3A when grown in spheroid (3D) culture, but not in a flat (2D) culture. Using tandem mass spectrometry we localized four different clipping sites in H3 and one clipping site in H2B. We show that in spheroid culture clipped H3 proteoforms are mainly...

  18. [MitraClip® for treatment of tricuspid valve insufficiency].

    Science.gov (United States)

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  19. Cystogenesis in ARPKD results from increased apoptosis in collecting duct epithelial cells of Pkhd1 mutant kidneys

    International Nuclear Information System (INIS)

    Hu, Bo; He, Xiusheng; Li, Ao; Qiu, Qingchao; Li, Cunxi; Liang, Dan; Zhao, Ping; Ma, Jie; Coffey, Robert J.; Zhan, Qimin; Wu, Guanqing

    2011-01-01

    Mutations in the PKHD1 gene result in autosomal recessive polycystic kidney disease (ARPKD) in humans. To determine the molecular mechanism of the cystogenesis in ARPKD, we recently generated a mouse model for ARPKD that carries a targeted mutation in the mouse orthologue of human PKHD1. The homozygous mutant mice display hepatorenal cysts whose phenotypes are similar to those of human ARPKD patients. By littermates of this mouse, we developed two immortalized renal collecting duct cell lines with Pkhd1 and two without. Under nonpermissive culture conditions, the Pkhd1 -/- renal cells displayed aberrant cell-cell contacts and tubulomorphogenesis. The Pkhd1 -/- cells also showed significantly reduced cell proliferation and elevated apoptosis. To validate this finding in vivo, we examined proliferation and apoptosis in the kidneys of Pkhd1 -/- mice and their wildtype littermates. Using proliferation (PCNA and Histone-3) and apoptosis (TUNEL and caspase-3) markers, similar results were obtained in the Pkhd1 -/- kidney tissues as in the cells. To identify the molecular basis of these findings, we analyzed the effect of Pkhd1 loss on multiple putative signaling regulators. We demonstrated that the loss of Pkhd1 disrupts multiple major phosphorylations of focal adhesion kinase (FAK), and these disruptions either inhibit the Ras/C-Raf pathways to suppress MEK/ERK activity and ultimately reduce cell proliferation, or suppress PDK1/AKT to upregulate Bax/caspase-9/caspase-3 and promote apoptosis. Our findings indicate that apoptosis may be a major player in the cyst formation in ARPKD, which may lead to new therapeutic strategies for human ARPKD.

  20. Kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin as prognostic markers in idiopathic membranous nephropathy.

    Science.gov (United States)

    Maas, Rutger Jh; van den Brand, Jan Ajg; Waanders, Femke; Meijer, Esther; Goor van, Harry; Peters, Hilde P; Hofstra, Julia M; Wetzels, Jack Fm

    2016-01-01

    Urinary excretion of alpha-1-microglobulin and beta-2-microglobulin reflects tubular damage and predicts outcome in patients with idiopathic membranous nephropathy with reasonable accuracy. Urinary kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin are novel biomarkers of tubular damage. We investigated if these markers could improve prediction of outcome in idiopathic membranous nephropathy. We measured kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin in urine samples from patients with idiopathic membranous nephropathy, who had nephrotic proteinuria and normal renal function. Excretion of alpha-1-microglobulin and beta-2-microglobulin had been measured previously. Progression was defined as a serum creatinine rise >30%, a rise in serum creatinine to an absolute value of ≥135 µmol/L, or a clinical decision to start immunosuppressive therapy. Remission was defined as proteinuria 50% reduction from baseline. Sixty-nine patients were included. Median follow-up was 35 months (interquartile range 18-63 months). Progression occurred in 30 patients (44%), and spontaneous remission in 36 (52%). Kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin excretion rates were significantly correlated with each other, and with alpha-1-microglobulin and beta-2-microglobulin. The areas under the receiver operating characteristic curves for progression were 0.75 (0.62-0.87) for kidney injury molecule-1 and 0.74 (0.62-0.87) for neutrophil gelatinase-associated lipocalin. In multivariate analysis with either alpha-1-microglobulin and beta-2-microglobulin, kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin did not independently predict outcome. Kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin excretion rates correlated with excretion rates of other tubular damage markers and predicted outcome in patients with idiopathic membranous nephropathy. They did not add prognostic value

  1. Comment: Kidney exchange to overcome financial barriers to kidney transplantation

    OpenAIRE

    Baines, L.S.; Jindal, R.M.

    2017-01-01

    Rees et al. have shown the feasibility of global kidney exchange (GKE) to overcome financial cost and address the current shortage of organs for transplantation. Wiseman and Gill, question their interpretation of definition of "financial incompatibility". The authors1 do not factor in the well documented cognitive and emotional aspects of kidney transplantation. Particularly, relevant to kidney transplantation is how patients calculate risk and the emotional turmoil characterised by anxiety a...

  2. Kidney Exchange to Overcome Financial Barriers to Kidney Transplantation.

    Science.gov (United States)

    Rees, M A; Dunn, T B; Kuhr, C S; Marsh, C L; Rogers, J; Rees, S E; Cicero, A; Reece, L J; Roth, A E; Ekwenna, O; Fumo, D E; Krawiec, K D; Kopke, J E; Jain, S; Tan, M; Paloyo, S R

    2017-03-01

    Organ shortage is the major limitation to kidney transplantation in the developed world. Conversely, millions of patients in the developing world with end-stage renal disease die because they cannot afford renal replacement therapy-even when willing living kidney donors exist. This juxtaposition between countries with funds but no available kidneys and those with available kidneys but no funds prompts us to propose an exchange program using each nation's unique assets. Our proposal leverages the cost savings achieved through earlier transplantation over dialysis to fund the cost of kidney exchange between developed-world patient-donor pairs with immunological barriers and developing-world patient-donor pairs with financial barriers. By making developed-world health care available to impoverished patients in the developing world, we replace unethical transplant tourism with global kidney exchange-a modality equally benefitting rich and poor. We report the 1-year experience of an initial Filipino pair, whose recipient was transplanted in the United states with an American donor's kidney at no cost to him. The Filipino donor donated to an American in the United States through a kidney exchange chain. Follow-up care and medications in the Philippines were supported by funds from the United States. We show that the logistical obstacles in this approach, although considerable, are surmountable. © 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  3. An Assessment of Urinary Biomarkers in a Series of Declined Human Kidneys Measured During ex-vivo Normothermic Kidney Perfusion

    OpenAIRE

    Hosgood, Sarah Anne; Nicholson, Michael Lennard

    2016-01-01

    BACKGROUND: The measurement of urinary biomarkers during ex-vivo normothermic kidney perfusion (EVKP) may aid in the assessment of a kidney prior to transplantation. This study measured levels of neutrophil gelatinase-associated lipocalin (NGAL), kidney injury molecule-1 (KIM-1) and endothelin-1 (ET-1) during EVKP in a series of discarded human kidneys. METHODS: Fifty six kidneys from deceased donors were recruited into the study. Each kidney underwent 60 minutes of EVKP and was scored based ...

  4. Determination of moulting events in rock lobsters from pleopod clipping.

    Science.gov (United States)

    Gardner, Caleb; Mills, David J

    2013-01-01

    Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  5. Determination of moulting events in rock lobsters from pleopod clipping.

    Directory of Open Access Journals (Sweden)

    Caleb Gardner

    Full Text Available Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  6. CLIP-seq analysis of multi-mapped reads discovers novel functional RNA regulatory sites in the human transcriptome.

    Science.gov (United States)

    Zhang, Zijun; Xing, Yi

    2017-09-19

    Crosslinking or RNA immunoprecipitation followed by sequencing (CLIP-seq or RIP-seq) allows transcriptome-wide discovery of RNA regulatory sites. As CLIP-seq/RIP-seq reads are short, existing computational tools focus on uniquely mapped reads, while reads mapped to multiple loci are discarded. We present CLAM (CLIP-seq Analysis of Multi-mapped reads). CLAM uses an expectation-maximization algorithm to assign multi-mapped reads and calls peaks combining uniquely and multi-mapped reads. To demonstrate the utility of CLAM, we applied it to a wide range of public CLIP-seq/RIP-seq datasets involving numerous splicing factors, microRNAs and m6A RNA methylation. CLAM recovered a large number of novel RNA regulatory sites inaccessible by uniquely mapped reads. The functional significance of these sites was demonstrated by consensus motif patterns and association with alternative splicing (splicing factors), transcript abundance (AGO2) and mRNA half-life (m6A). CLAM provides a useful tool to discover novel protein-RNA interactions and RNA modification sites from CLIP-seq and RIP-seq data, and reveals the significant contribution of repetitive elements to the RNA regulatory landscape of the human transcriptome. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  7. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi; Mandal, Papita; Tomar, Raghuvir S.

    2016-01-01

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have

  8. Endothelin 1 gene is not a major modifier of chronic kidney disease advancement among the autosomal dominant polycystic kidney disease patients

    Directory of Open Access Journals (Sweden)

    Annapareddy Shiva Nagendra Reddy

    2016-01-01

    Full Text Available Introduction: Autosomal dominant polycystic kidney disease (ADPKD is characterized by the presence of numerous cysts in the kidney and manifest with various renal and extra-renal complications leading to ESRD. Endothelin may contribute to various renal and extra-renal manifestations pointing to genetic and environmental modifying factors that alter the risk of developing chronic kidney disease (CKD in ADPKD. In the present study we investigated six genes coding for endothelin 1 (EDN1 tagging-single nucleotide polymorphisms (tag-SNPs to unravel the EDN1 gene modifier effect for renal disease progression in ADPKD. Materials and Methods: The tag-SNPs were genotyped using FRET-based KASPar method in 108 ADPKD patients and 119 healthy subjects. Cochran-Armitage trend test was used to determine the association between ADPKD and EDN1 tag-SNPs. Multivariate logistic regression analysis was performed to assess the effect of tag-SNPs on CKD progression. The relationship between different CKD stages and hypertension and their interaction Mantel-Haenszel stratified analysis was performed. Results: All loci are polymorphic and followed Hardy-Weinberg equilibrium. Distribution of EDN1 genotypes and haplotypes in control and ADPKD is not statistically significant. Five SNPs covering 3.4 kb forming single LD block, but the LD was not strong between SNPs. The EDN1 genotypes are not contributing to the CKD advancement among the ADPKD patients. Conclusion: These results suggest that the EDN1 gene is not a major modifier of CKD advancement among ADPKD patients.

  9. Cordyceps cicadae extracts ameliorate renal malfunction in a remnant kidney model.

    Science.gov (United States)

    Zhu, Rong; Chen, Yi-ping; Deng, Yue-yi; Zheng, Rong; Zhong, Yi-fei; Wang, Lin; Du, Lan-ping

    2011-12-01

    Chronic kidney disease (CKD) is a growing public health problem with an urgent need for new pharmacological agents. Cordyceps cicadae is widely used in traditional Chinese medicine (TCM) and has potential renoprotective benefits. The current study aimed to determine any scientific evidence to support its clinical use. We analyzed the potential of two kinds of C. cicadae extract, total extract (TE) and acetic ether extract (AE), in treating kidney disease simulated by a subtotal nephrectomy (SNx) model. Sprague-Dawley rats were divided randomly into seven groups: sham-operated group, vehicle-treated SNx, Cozaar, 2 g/(kg∙d) TE SNx, 1 g/(kg∙d) TE SNx, 92 mg/(kg∙d) AE SNx, and 46 mg/(kg∙d) AE SNx. Renal injury was monitored using urine and serum analyses, and hematoxylin and eosin (HE) and periodic acid-Schiff (PAS) stainings were used to analyze the level of fibrosis. The expression of type IV collagen (Col IV), fibronectin (FN), transforming growth factor-β1 (TGF-β1), and connective tissue growth factor (CTGF) was detected by immunohistochemistry. Renal injury, reflected in urine and serum analyses, and pathological changes induced by SNx were attenuated by TE and AE intervention. The depositions of Col IV and FN were also decreased by the treatments and were accompanied by reduced expression of TGF-β1 and CTGF. In some respects, 2 g/(kg∙d) of TE produced better effects than Cozaar. For the first time, we have shown that C. cicadae may inhibit renal fibrosis in vivo through the TGF-β1/CTGF pathway. Therefore, we conclude that the use of C. cicadae could provide a rational strategy for combating renal fibrosis.

  10. Elevated urinary levels of kidney injury molecule-1 among Chinese factory workers exposed to trichloroethylene

    Science.gov (United States)

    Vermeulen, Roel; Huang, Hanlin; Rothman, Nathaniel; Lan, Qing

    2012-01-01

    Epidemiological studies suggest that trichloroethylene (TCE) exposure may be associated with renal cancer. The biological mechanisms involved are not exactly known although nephrotoxicity is believed to play a role. Studies on TCE nephrotoxicity among humans, however, have been largely inconsistent. We studied kidney toxicity in Chinese factory workers exposed to TCE using novel sensitive nephrotoxicity markers. Eighty healthy workers exposed to TCE and 45 comparable unexposed controls were included in the present analyses. Personal TCE exposure measurements were taken over a 2-week period before urine collection. Ninety-six percent of workers were exposed to TCE below the current US Occupational Safety and Health Administration permissible exposure limit (100 ppm 8h TWA), with a mean (SD) of 22.2 (35.9) ppm. Kidney injury molecule-1 (KIM-1) and Pi-glutathione S transferase (GST) alpha were elevated among the exposed subjects as compared with the unexposed controls with a strong exposure-response association between individual estimates of TCE exposure and KIM-1 (P < 0.0001). This is the first report to use a set of sensitive nephrotoxicity markers to study the possible effects of TCE on the kidneys. The findings suggest that at relatively low occupational exposure levels a toxic effect on the kidneys can be observed. This finding supports the biological plausibility of linking TCE exposure and renal cancer. Abbreviations:GSTglutathione-S-transferaseKIM-1kidney injury molecule-1NAGN-acetyl-beta-(d)-glucosaminidaseOVMorganic vapour monitoringTCEtrichloroethyleneVEGFvascular endothelial growth factor. PMID:22665366

  11. Modeling elastic wave propagation in kidney stones with application to shock wave lithotripsy.

    Science.gov (United States)

    Cleveland, Robin O; Sapozhnikov, Oleg A

    2005-10-01

    A time-domain finite-difference solution to the equations of linear elasticity was used to model the propagation of lithotripsy waves in kidney stones. The model was used to determine the loading on the stone (principal stresses and strains and maximum shear stresses and strains) due to the impact of lithotripsy shock waves. The simulations show that the peak loading induced in kidney stones is generated by constructive interference from shear waves launched from the outer edge of the stone with other waves in the stone. Notably the shear wave induced loads were significantly larger than the loads generated by the classic Hopkinson or spall effect. For simulations where the diameter of the focal spot of the lithotripter was smaller than that of the stone the loading decreased by more than 50%. The constructive interference was also sensitive to shock rise time and it was found that the peak tensile stress reduced by 30% as rise time increased from 25 to 150 ns. These results demonstrate that shear waves likely play a critical role in stone comminution and that lithotripters with large focal widths and short rise times should be effective at generating high stresses inside kidney stones.

  12. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially

  13. Global gene expression profiling in PAI-1 knockout murine heart and kidney: molecular basis of cardiac-selective fibrosis.

    Directory of Open Access Journals (Sweden)

    Asish K Ghosh

    Full Text Available Fibrosis is defined as an abnormal matrix remodeling due to excessive synthesis and accumulation of extracellular matrix proteins in tissues during wound healing or in response to chemical, mechanical and immunological stresses. At present, there is no effective therapy for organ fibrosis. Previous studies demonstrated that aged plasminogen activator inhibitor-1 (PAI-1 knockout mice develop spontaneously cardiac-selective fibrosis without affecting any other organs. We hypothesized that differential expressions of profibrotic and antifibrotic genes in PAI-1 knockout hearts and unaffected organs lead to cardiac selective fibrosis. In order to address this prediction, we have used a genome-wide gene expression profiling of transcripts derived from aged PAI-1 knockout hearts and kidneys. The variations of global gene expression profiling were compared within four groups: wildtype heart vs. knockout heart; wildtype kidney vs. knockout kidney; knockout heart vs. knockout kidney and wildtype heart vs. wildtype kidney. Analysis of illumina-based microarray data revealed that several genes involved in different biological processes such as immune system processing, response to stress, cytokine signaling, cell proliferation, adhesion, migration, matrix organization and transcriptional regulation were affected in hearts and kidneys by the absence of PAI-1, a potent inhibitor of urokinase and tissue-type plasminogen activator. Importantly, the expressions of a number of genes, involved in profibrotic pathways including Ankrd1, Pi16, Egr1, Scx, Timp1, Timp2, Klf6, Loxl1 and Klotho, were deregulated in PAI-1 knockout hearts compared to wildtype hearts and PAI-1 knockout kidneys. While the levels of Ankrd1, Pi16 and Timp1 proteins were elevated during EndMT, the level of Timp4 protein was decreased. To our knowledge, this is the first comprehensive report on the influence of PAI-1 on global gene expression profiling in the heart and kidney and its implication

  14. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    Science.gov (United States)

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (psubdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  15. Clipping of tumour resection margins allows accurate target volume delineation in head and neck cancer adjuvant radiation therapy

    International Nuclear Information System (INIS)

    Bittermann, Gido; Wiedenmann, Nicole; Bunea, Andrei; Schwarz, Steffen J.; Grosu, Anca-L.; Schmelzeisen, Rainer; Metzger, Marc C.

    2015-01-01

    Background: Accurate tumour bed localisation is a key requirement for adjuvant radiotherapy. A new procedure is described for head and neck cancer treatment that improves tumour bed localisation using titanium clips. Materials and methods: Following complete local excision of the primary tumour, the tumour bed was marked with titanium clips. Preoperative gross target volume (GTV) and postoperative tumour bed were examined and the distances between the centres of gravity were evaluated. Results: 49 patients with squamous cell carcinoma of the oral cavity were prospectively enrolled in this study. All patients underwent tumour resection, neck lymph node dissection and defect reconstruction in one stage. During surgery, 7–49 clips were placed in the resection cavity. Surgical clip insertion was successful in 88% (n = 43). Clip identification and tumour bed delineation was successful in all 43 patients. The overall distance between the centres of gravity of the preoperative tumour extension to the tumour bed was 0.9 cm. A significant relationship between the preoperative tumour extension and the postoperative tumour bed volume could be demonstrated. Conclusion: We demonstrate a precise delineation of the former tumour cavity. Improvements in tumour bed delineation allow an increase of accuracy for adjuvant treatment

  16. Role of Integrin-Beta1 in Polycystic Kidney Disease

    Science.gov (United States)

    2012-04-01

    interactions affect proliferation and cell differentiation2. We previously showed an increase of integrin-!2ŕ expression in polycystin-1 (PC1) deficient...that since the Cre activity in TgAqp2-Cre transgenic mouse was observed also in testes, our breeding scheme was devised to ensure maternal ...inheritance of the transgene, as paternal transmission would lead to gene recombination not only in the kidneys, but also in sperm and the resulting

  17. Novel mTORC1 and 2 Signaling Pathways in Polycystic Kidney Disease (PKD)

    Science.gov (United States)

    2017-09-01

    30 27 32 2K (g) 0.35 0.53 0.36 * 2K/TBW (%) 1.1 2.0 1.2 * Cyst volume (%) 0 40.1 14.6 * No of cysts/kidney 0 5.3 0.8 * Heart wt (g) 0.3 0.15 0.17...some delay in the project. There were no other delays in the project Changes that had a significant impact on expenditures Delays in hiring PRA... Heart wt (g) 0.3 0.15 0.17 15 BUN (mg/dL) 24 29 25 SCr (mg/dL) 0.22 0.33 0.2* 2K/TBW (%) Two kidney/total body weight, *pɘ.05 vs. Pkd1

  18. Deregulated Renal Calcium and Phosphate Transport during Experimental Kidney Failure.

    Directory of Open Access Journals (Sweden)

    Wilco P Pulskens

    Full Text Available Impaired mineral homeostasis and inflammation are hallmarks of chronic kidney disease (CKD, yet the underlying mechanisms of electrolyte regulation during CKD are still unclear. Here, we applied two different murine models, partial nephrectomy and adenine-enriched dietary intervention, to induce kidney failure and to investigate the subsequent impact on systemic and local renal factors involved in Ca(2+ and Pi regulation. Our results demonstrated that both experimental models induce features of CKD, as reflected by uremia, and elevated renal neutrophil gelatinase-associated lipocalin (NGAL expression. In our model kidney failure was associated with polyuria, hypercalcemia and elevated urinary Ca(2+ excretion. In accordance, CKD augmented systemic PTH and affected the FGF23-αklotho-vitamin-D axis by elevating circulatory FGF23 levels and reducing renal αklotho expression. Interestingly, renal FGF23 expression was also induced by inflammatory stimuli directly. Renal expression of Cyp27b1, but not Cyp24a1, and blood levels of 1,25-dihydroxy vitamin D3 were significantly elevated in both models. Furthermore, kidney failure was characterized by enhanced renal expression of the transient receptor potential cation channel subfamily V member 5 (TRPV5, calbindin-D28k, and sodium-dependent Pi transporter type 2b (NaPi2b, whereas the renal expression of sodium-dependent Pi transporter type 2a (NaPi2a and type 3 (PIT2 were reduced. Together, our data indicates two different models of experimental kidney failure comparably associate with disturbed FGF23-αklotho-vitamin-D signalling and a deregulated electrolyte homeostasis. Moreover, this study identifies local tubular, possibly inflammation- or PTH- and/or FGF23-associated, adaptive mechanisms, impacting on Ca(2+/Pi homeostasis, hence enabling new opportunities to target electrolyte disturbances that emerge as a consequence of CKD development.

  19. Effects of Qiangji Jianli Yin on the hypothalamus CRH contents and plasma ACTH, cortisol levels in rat models of kidney-yang deficiency syndrome

    International Nuclear Information System (INIS)

    Zhao Hui; Chen Zhixi; Chen Jinyan; Li Zhiqiang; He Zanhou

    2007-01-01

    Objective: To investigate the effects of qiangji jianli yin on hypothalamus CRH contents and plasma ACTH, Cortisol levels in rat models with kidney-yang deficiency syndrome. Methods: Rat models of kidney-yang deficiency syndrome were prepared with intramuscular injuection of hydroeortisone and divided into 5 groups: (1) no further treatment, n=13 (2) treated with high dosage d qiangji jiandi yin, n=12 (3) treated with medium dosage of qiangji jianli yin, n=12 (4) treated with low dosage of qiangji jianli yin n=12, (5) treated with yougui wan, n=12. Ten rats injuected with intramuscular distilled water only served as controls. The animals were sacrificied 14 days later and the hypothalamus CRH contents as well as plasma AOM and cortisol levels were measured with RIA. The thymus gland weight index and the adrenal gland index were calculated. Results: (1) The hypothalamus CRH contents and plasma ACTH, cortisol levels were significantly lower (P<0.01) in the rat models of kidney-yang deficiency syndrome without any treatment thas those in controls rats; the thymus and adrenal gland weight index were significantly decreased too (P <0.01). The CRH conteats and ACTH, cortisol levels in all the three group of rat model treated with different dosage of qiangji jianli yin were significantly higher than those in the models without any treatment (P<0.05-0.01). Conclusion: In rat models of kidney-yang deficiency syndrome, dysfunction of the hypothalamus-pituitary-adrenal axis (HPAA) led to decreased secretion of related hormones. The HPAA function might be partially restored with administation of qiangji jianli yin. (authors)

  20. Diagnostic value of urinary kidney injury molecule 1 for acute kidney injury: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Xinghua Shao

    Full Text Available BACKGROUND: Urinary Kidney Injury Molecule 1 (KIM-1 is a proximal tubular injury biomarker for early detection of acute kidney injury (AKI, with variable performance characteristics depending on clinical and population settings. METHODS: Meta-analysis was performed to assess the diagnostic value of urinary KIM-1 in AKI. Relevant studies were searched from MEDLINE, EMBASE, Pubmed, Elsevier Science Direct, Scopus, Web of Science, Google Scholar and Cochrane Library. Meta-analysis methods were used to pool sensitivity and specificity and to construct summary receiver operating characteristic (SROC curves. RESULTS: A total of 2979 patients from 11 eligible studies were enrolled in the analysis. Five prospective cohorts, two cross-sectional and four case-control studies were identified for meta-analysis. The estimated sensitivity of urinary KIM-1 for the diagnosis of AKI was 74.0% (95% CI, 61.0%-84.0%, and specificity was 86.0% (95% CI, 74.0%-93.0%. The SROC analysis showed an area under the curve of 0.86(0.83-0.89. Subgroup analysis suggested that population settings and detection time were the key factors affecting the efficiency of KIM-1 for AKI diagnosis. LIMITATION: Various population settings, different definition of AKI and Serum creatinine level used as the standard might have influence on AKI diagnosis. The relatively small number of studies and heterogeneity between them also affected the evaluation. CONCLUSION: Urinary KIM-1 may be a promising biomarker for early detection of AKI with considerable predictive value, especially for cardiac surgery patients, and its potential value needs to be validated in large studies and across a broader scope of clinical settings.

  1. First- and third-party ground truth for key frame extraction from consumer video clips

    Science.gov (United States)

    Costello, Kathleen; Luo, Jiebo

    2007-02-01

    Extracting key frames (KF) from video is of great interest in many applications, such as video summary, video organization, video compression, and prints from video. KF extraction is not a new problem. However, current literature has been focused mainly on sports or news video. In the consumer video space, the biggest challenges for key frame selection from consumer videos are the unconstrained content and lack of any preimposed structure. In this study, we conduct ground truth collection of key frames from video clips taken by digital cameras (as opposed to camcorders) using both first- and third-party judges. The goals of this study are: (1) to create a reference database of video clips reasonably representative of the consumer video space; (2) to identify associated key frames by which automated algorithms can be compared and judged for effectiveness; and (3) to uncover the criteria used by both first- and thirdparty human judges so these criteria can influence algorithm design. The findings from these ground truths will be discussed.

  2. Risk of a Second Kidney Carcinoma Following Childhood Cancer: Role of Chemotherapy and Radiation Dose to Kidneys.

    Science.gov (United States)

    de Vathaire, Florent; Scwhartz, Boris; El-Fayech, Chiraz; Allodji, Rodrigue Sètchéou; Escudier, Bernard; Hawkins, Mike; Diallo, Ibrahima; Haddy, Nadia

    2015-11-01

    Kidney carcinoma is a rare second malignancy following childhood cancer. We sought to quantify risk and assess risk factors for kidney carcinoma following treatment for childhood cancer. We evaluated a cohort of 4,350 patients who were 5-year cancer survivors and had been treated for cancer as children in France and the United Kingdom. Patients were treated between 1943 and 1985, and were followed for an average of 27 years. Radiation dose to the kidneys during treatment was estimated with dedicated software, regardless of the site of childhood cancer. Kidney carcinoma developed in 13 patients. The cumulative incidence of kidney carcinoma was 0.62% (95% CI 0.27%-1.45%) at 40 years after diagnosis, which was 13.3-fold higher (95% CI 7.1-22.3) than in the general population. The absolute excess risk strongly increased with longer duration of followup (p kidney carcinoma was 5.7-fold higher (95% CI 1.4-14.7) if radiotherapy was not performed or less than 1 Gy had been absorbed by the kidney but 66.3-fold higher (95% CI 23.8-142.5) if the radiation dose to the kidneys was 10 to 19 Gy and 14.5-fold higher (95% CI 0.8-63.9) for larger radiation doses to the kidney. Treatment with chemotherapy increased the risk of kidney carcinoma (RR 5.1, 95% CI 1.1-22.7) but we were unable to identify a specific drug or drug category responsible for this effect. Moderate radiation dose to the kidneys during childhood cancer treatment increases the risk of a second kidney carcinoma. This incidence will be further increased when childhood cancer survivors reach old age. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Tetraethylammonium block of water flux in Aquaporin-1 channels expressed in kidney thin limbs of Henle's loop and a kidney-derived cell line.

    Directory of Open Access Journals (Sweden)

    Pannabecker Thomas L

    2002-03-01

    Full Text Available Abstract Background Aquaporin-1 (AQP1 channels are constitutively active water channels that allow rapid transmembrane osmotic water flux, and also serve as cyclic-GMP-gated ion channels. Tetraethylammonium chloride (TEA; 0.05 to 10 mM was shown previously to inhibit the osmotic water permeability of human AQP1 channels expressed in Xenopus oocytes. The purpose of the present study was to determine if TEA blocks osmotic water flux of native AQP1 channels in kidney, and recombinant AQP1 channels expressed in a kidney derived MDCK cell line. We also demonstrate that TEA does not inhibit the cGMP-dependent ionic conductance of AQP1 expressed in oocytes, supporting the idea that water and ion fluxes involve pharmacologically distinct pathways in the AQP1 tetrameric complex. Results TEA blocked water permeability of AQP1 channels in kidney and kidney-derived cells, demonstrating this effect is not limited to the oocyte expression system. Equivalent inhibition is seen in MDCK cells with viral-mediated AQP1 expression, and in rat renal descending thin limbs of Henle's loops which abundantly express native AQP1, but not in ascending thin limbs which do not express AQP1. External TEA (10 mM does not block the cGMP-dependent AQP1 ionic conductance, measured by two-electrode voltage clamp after pre-incubation of oocytes in 8Br-cGMP (10–50 mM or during application of the nitric oxide donor, sodium nitroprusside (2–4 mM. Conclusions TEA selectively inhibits osmotic water permeability through native and heterologously expressed AQP1 channels. The pathways for water and ions in AQP1 differ in pharmacological sensitivity to TEA, and are consistent with the idea of independent solute pathways within the channel structure. The results confirm the usefulness of TEA as a pharmacological tool for the analysis of AQP1 function.

  4. Testing Danegaptide Effects on Kidney Function after Ischemia/Reperfusion Injury in a New Porcine Two Week Model.

    Directory of Open Access Journals (Sweden)

    Chris Amdisen

    Full Text Available Ischemia/reperfusion injury (I/R-I is a leading cause of acute kidney injury (AKI and is associated with increased mortality. Danegaptide is a selective modifier of the gap junction protein connexion 43. It has cytoprotective as well as anti-arrhythmic properties and has been shown to reduce the size of myocardial infarct in pigs. The aim of this study was to investigate the ischemia-protective effect of Danegaptide in a porcine renal I/R-I model with two weeks follow up.Unilateral renal I/R-I was induced in pigs by clamping the left renal artery over a two hour period. The model allowed examination of renal blood flow by magnetic resonance imaging (MRI and the measurement of single kidney GFR two weeks after injury. Eleven animals were randomized to Danegaptide-infusion while nine animals received placebo. Kidney histology and urinary neutrophil gelatinase-associated lipocalin (NGAL excretion were included as markers of AKI.Unilateral kidney I/R-I resulted in an immediate ~50% GFR reduction, associated with a four-fold increase in urinary NGAL-excretion. Fourteen days after I/R-I, the total GFR was ~75% of baseline with a significantly lower GFR in the injured left kidney compared to the right kidney. No differences in GFR were observed between the treated and non-treated animals immediately after I/R-I or at Day 14. Furthermore, no differences were observed in the urinary excretion of NGAL, renal blood flow or other markers of renal function.As expected this porcine renal I/R-I model was associated with reduced GFR two weeks after injury. Danegaptide did not improve renal function after I/R-I.

  5. [Augmented reality for image guided therapy (ARIGT) of kidney tumor during nephron sparing surgery (NSS): animal model and clinical approach].

    Science.gov (United States)

    Drewniak, Tomasz; Rzepecki, Maciej; Juszczak, Kajetan; Kwiatek, Wojciech; Bielecki, Jakub; Zieliński, Krzysztof; Ruta, Andrzej; Czekierda, Łukasz; Moczulskis, Zbigniew

    2011-01-01

    The main problem in nephron sparing surgery (NSS) is to preserve renal tumors oncological purity during the removal of the tumor with a margin of macroscopically unchanged kidney tissue while keeping the largest possible amount of normal parenchyma of the operated kidney. The development of imaging techniques, in particular IGT (Image Guided Therapy) allows precise imaging of the surgical field and, therefore, is essential in improving the effectiveness of NSS (increase of nephron sparing with the optimal radicality). The aim of this study was to develop a method of the three-dimensional (3D) imaging of the kidney tumor and its lodge in the operated kidney using 3D laser scanner during NSS procedure. Additionally, the animal model of visualization was developed. The porcine kidney model was used to test the set built up with HD cameras and linear laser scanner connected to a laptop with graphic software (David Laser Scanner, Germany) showing the surface of the kidney and the lodge after removal the chunk of renal parenchyma. Additionally, the visualization and reconstruction was performed on animal porcine model. Moreover, 5 patients (3 women, 2 men) aged from 37 to 68 years (mean 56), diagnosed with kidney tumors in CT scans with a diameter of 3.7-6.9 cm (mean 4.9) were operated in our Department this year, scanning the surface during the treatment with the kidney tumor and kidney tumor after it is removed with a margin of renal tissue. In one case, the lodge of removed tumor was scanned. Dimensions in 3D reconstruction images of laser scans in the study of animal model and the images obtained intraoperatively were compared with the dimensions evaluated during preoperative CT scans, intraoperative measurements. Three-dimensional imaging laser scanner operating field loge resected tumor and the tumor on the kidney of animal models and during NSS treatments for patients with kidney tumors is possible in real time with an accuracy of -2 mm do +9 mm (+/- 3 mm). The

  6. The long noncoding RNA Tug1 connects metabolic changes with kidney disease in podocytes.

    Science.gov (United States)

    Li, Szu Yuan; Susztak, Katalin

    2016-11-01

    An increasing amount of evidence suggests that metabolic alterations play a key role in chronic kidney disease (CKD) pathogenesis. In this issue of the JCI, Long et al. report that the long noncoding RNA (lncRNA) taurine-upregulated 1 (Tug1) contributes to CKD development. The authors show that Tug1 regulates mitochondrial function in podocytes by epigenetic targeting of expression of the transcription factor PPARγ coactivator 1α (PGC-1α, encoded by Ppargc1a). Transgenic overexpression of Tug1 specifically in podocytes ameliorated diabetes-induced CKD in mice. Together, these results highlight an important connection between lncRNA-mediated metabolic alterations in podocytes and kidney disease development.

  7. A novel mutation causing nephronophthisis in the Lewis polycystic kidney rat localises to a conserved RCC1 domain in Nek8

    Directory of Open Access Journals (Sweden)

    McCooke John K

    2012-08-01

    Full Text Available Abstract Background Nephronophthisis (NPHP as a cause of cystic kidney disease is the most common genetic cause of progressive renal failure in children and young adults. NPHP is characterized by abnormal and/or loss of function of proteins associated with primary cilia. Previously, we characterized an autosomal recessive phenotype of cystic kidney disease in the Lewis Polycystic Kidney (LPK rat. Results In this study, quantitative trait locus analysis was used to define a ~1.6Mbp region on rat chromosome 10q25 harbouring the lpk mutation. Targeted genome capture and next-generation sequencing of this region identified a non-synonymous mutation R650C in the NIMA (never in mitosis gene a- related kinase 8 ( Nek8 gene. This is a novel Nek8 mutation that occurs within the regulator of chromosome condensation 1 (RCC1-like region of the protein. Specifically, the R650C substitution is located within a G[QRC]LG repeat motif of the predicted seven bladed beta-propeller structure of the RCC1 domain. The rat Nek8 gene is located in a region syntenic to portions of human chromosome 17 and mouse 11. Scanning electron microscopy confirmed abnormally long cilia on LPK kidney epithelial cells, and fluorescence immunohistochemistry for Nek8 protein revealed altered cilia localisation. Conclusions When assessed relative to other Nek8 NPHP mutations, our results indicate the whole propeller structure of the RCC1 domain is important, as the different mutations cause comparable phenotypes. This study establishes the LPK rat as a novel model system for NPHP and further consolidates the link between cystic kidney disease and cilia proteins.

  8. The source parameters of 2013 Mw6.6 Lushan earthquake constrained with the restored local clipped seismic waveforms

    Science.gov (United States)

    Hao, J.; Zhang, J. H.; Yao, Z. X.

    2017-12-01

    We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake

  9. Improved Structure and Function in Autosomal Recessive Polycystic Rat Kidneys with Renal Tubular Cell Therapy.

    Science.gov (United States)

    Kelly, K J; Zhang, Jizhong; Han, Ling; Kamocka, Malgorzata; Miller, Caroline; Gattone, Vincent H; Dominguez, Jesus H

    2015-01-01

    Autosomal recessive polycystic kidney disease is a truly catastrophic monogenetic disease, causing death and end stage renal disease in neonates and children. Using PCK female rats, an orthologous model of autosomal recessive polycystic kidney disease harboring mutant Pkhd1, we tested the hypothesis that intravenous renal cell transplantation with normal Sprague Dawley male kidney cells would improve the polycystic kidney disease phenotype. Cytotherapy with renal cells expressing wild type Pkhd1 and tubulogenic serum amyloid A1 had powerful and sustained beneficial effects on renal function and structure in the polycystic kidney disease model. Donor cell engraftment and both mutant and wild type Pkhd1 were found in treated but not control PCK kidneys 15 weeks after the final cell infusion. To examine the mechanisms of global protection with a small number of transplanted cells, we tested the hypothesis that exosomes derived from normal Sprague Dawley cells can limit the cystic phenotype of PCK recipient cells. We found that renal exosomes originating from normal Sprague Dawley cells carried and transferred wild type Pkhd1 mRNA to PCK cells in vivo and in vitro and restricted cyst formation by cultured PCK cells. The results indicate that transplantation with renal cells containing wild type Pkhd1 improves renal structure and function in autosomal recessive polycystic kidney disease and may provide an intra-renal supply of normal Pkhd1 mRNA.

  10. Economic impact of heart failure according to the effects of kidney failure.

    Science.gov (United States)

    Sicras Mainar, Antoni; Navarro Artieda, Ruth; Ibáñez Nolla, Jordi

    2015-01-01

    To evaluate the use of health care resources and their cost according to the effects of kidney failure in heart failure patients during 2-year follow-up in a population setting. Observational retrospective study based on a review of medical records. The study included patients ≥ 45 years treated for heart failure from 2008 to 2010. The patients were divided into 2 groups according to the presence/absence of KF. Main outcome variables were comorbidity, clinical status (functional class, etiology), metabolic syndrome, costs, and new cases of cardiovascular events and kidney failure. The cost model included direct and indirect health care costs. Statistical analysis included multiple regression models. The study recruited 1600 patients (prevalence, 4.0%; mean age 72.4 years; women, 59.7%). Of these patients, 70.1% had hypertension, 47.1% had dyslipidemia, and 36.2% had diabetes mellitus. We analyzed 433 patients (27.1%) with kidney failure and 1167 (72.9%) without kidney failure. Patients with kidney failure were associated with functional class III-IV (54.1% vs 40.8%) and metabolic syndrome (65.3% vs 51.9%, P<.01). The average unit cost was €10,711.40. The corrected cost in the presence of kidney failure was €14,868.20 vs €9,364.50 (P=.001). During follow-up, 11.7% patients developed ischemic heart disease, 18.8% developed kidney failure, and 36.1% developed heart failure exacerbation. Comorbidity associated with heart failure is high. The presence of kidney failure increases the use of health resources and leads to higher costs within the National Health System. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  11. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  12. Excisional wound healing is delayed in a murine model of chronic kidney disease.

    Directory of Open Access Journals (Sweden)

    Akhil K Seth

    Full Text Available BACKGROUND: Approximately 15% of the United States population suffers from chronic kidney disease (CKD, often demonstrating an associated impairment in wound healing. This study outlines the development of a surgical murine model of CKD in order to investigate the mechanisms underlying this impairment. METHODS: CKD was induced in mice by partial cauterization of one kidney cortex and contralateral nephrectomy, modifying a previously published technique. After a minimum of 6-weeks, splinted, dorsal excisional wounds were created to permit assessment of wound healing parameters. Wounds were harvested on postoperative days (POD 0, 3, 7, and 14 for histological, immunofluorescent, and quantitative PCR (qPCR. RESULTS: CKD mice exhibited deranged blood chemistry and hematology profiles, including profound uremia and anemia. Significant decreases in re-epithelialization and granulation tissue deposition rates were found in uremic mice wounds relative to controls. On immunofluorescent analysis, uremic mice demonstrated significant reductions in cellular proliferation (BrdU and angiogenesis (CD31, with a concurrent increase in inflammation (CD45 as compared to controls. CKD mice also displayed differential expression of wound healing-related genes (VEGF, IL-1β, eNOS, iNOS on qPCR. CONCLUSIONS: These findings represent the first reported investigation of cutaneous healing in a CKD animal model. Ongoing studies of this significantly delayed wound healing phenotype include the establishment of renal failure model in diabetic strains to study the combined effects of CKD and diabetes.

  13. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    Science.gov (United States)

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  14. Diffusion-weighted MRI of kidneys in healthy volunteers and living kidney donors

    International Nuclear Information System (INIS)

    Sulkowska, K.; Palczewski, P.; Duda-Zysk, A.; Szeszkowski, W.; Wojcik, D.; Kownacka-Piotrowska, D.; Gołebiowski, M.

    2015-01-01

    Aim: To establish the normal apparent diffusion coefficient (ADC) values in healthy kidneys, comparing them with the literature, and assessing the correlation between ADC values, creatinine blood level, and glomerular filtration rate (GFR). Materials and methods: Twenty-four healthy volunteers and 26 living kidney donors were examined on a 1.5 T magnetic resonance imaging (MRI) unit. Two diffusion-weighted imaging (DWI) sequences were included in the study protocol (protocol 1 with 16 b-values, protocol 2 with 10 b-values) before the examination blood and urine samples were collected. The GFR was calculated using Cockcroft & Gault and MDRD (Modification of Diet In Renal Disease) formulas and the ADC values were measured separately for the cortex and medulla of each kidney by two independent observers. All statistical analyses were performed using the STATISTICA (version 10.0) software package. Data were analysed using an unpaired t-test; p<0.05 indicated a statistically significant difference. Results: The average ADC value for protocol 1 for the cortex was 2.26×10 −3  mm 2 /s, for the medulla 2.21×10 −3  mm 2 /s. In protocol 2, the respective values were 2.13×10 −3  mm 2 /s and 2.06×10 −3  mm 2 /s. Neither statistically significant interobserver differences nor correlation between ADC values, GFR, and creatinine serum level were observed. Conclusion: The reference ADC values were established. The measurements show high interobserver consistency. The differences in ADC values reported in the literature suggest dependence on the equipment and methodology and point to the necessity of obtaining ADC norms for each MRI unit. -- Highlights: •Magnetic resonance diffusion-weighted imaging of kidneys. •Apparent diffusion coefficient in healthy individuals. •Monoexponential model of diffusion

  15. A pitfall of glomerular sieving: profibrotic and matrix proteins derive from the Bowman's capsule and not the glomerular tuft in rats with renovascular hypertension.

    Science.gov (United States)

    Steinmetz, O M; Panzer, U; Fehr, S; Meyer-Schwesinger, C; Stahl, R A K; Wenzel, U O

    2007-10-01

    The glomeruli in the non-clipped kidney of rats with 2-kidney, 1-clip hypertension are a classical model for studying the mechanisms of glomerular injury. In the present study, we compared the glomerular expression of PAI-1 and collagen I alpha1 mRNA from glomeruli isolated by the classic technique of sieving with the recently developed technique of tissue laser microdissection. For quantification of mRNA from both methods, real-time PCR was used. Real-time PCR revealed a 9.0 +/- 1.3- and a 7.1 +/- 0.2-fold induction of PAI-1 and collagen I alpha 1, respectively, in the glomeruli from hypertensive rats isolated by sieving. However, in situ hybridization and microdissection revealed that expression of both mRNAs was mainly from the Bowman's capsule and not from the glomerular tuft (10.7 +/- 1.3- and 7.2 +/- 0.6-fold higher induction in whole glomeruli compared with tuft alone). This emphasizes that studies focusing on processes in the mesangium, endothelial cells or podocytes should not rely on glomeruli obtained by sieving. Rather, a technique like the laser microdissection or in situ hybridization should be applied which allows the clear separation of different glomerular and periglomerular compartments.

  16. 33 CFR 183.532 - Clips, straps, and hose clamps.

    Science.gov (United States)

    2010-07-01

    ... resistant material; and (2) Not cut or abrade the fuel line. (b) If tested in accordance with the fire test under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips...

  17. Computer-assisted imaging algorithms facilitate histomorphometric quantification of kidney damage in rodent renal failure models

    Directory of Open Access Journals (Sweden)

    Marcin Klapczynski

    2012-01-01

    Full Text Available Introduction: Surgical 5/6 nephrectomy and adenine-induced kidney failure in rats are frequently used models of progressive renal failure. In both models, rats develop significant morphological changes in the kidneys and quantification of these changes can be used to measure the efficacy of prophylactic or therapeutic approaches. In this study, the Aperio Genie Pattern Recognition technology, along with the Positive Pixel Count, Nuclear and Rare Event algorithms were used to quantify histological changes in both rat renal failure models. Methods: Analysis was performed on digitized slides of whole kidney sagittal sections stained with either hematoxylin and eosin or immunohistochemistry with an anti-nestin antibody to identify glomeruli, regenerating tubular epithelium, and tubulointerstitial myofibroblasts. An anti-polymorphonuclear neutrophil (PMN antibody was also used to investigate neutrophil tissue infiltration. Results: Image analysis allowed for rapid and accurate quantification of relevant histopathologic changes such as increased cellularity and expansion of glomeruli, renal tubular dilatation, and degeneration, tissue inflammation, and mineral aggregation. The algorithms provided reliable and consistent results in both control and experimental groups and presented a quantifiable degree of damage associated with each model. Conclusion: These algorithms represent useful tools for the uniform and reproducible characterization of common histomorphologic features of renal injury in rats.

  18. A clip domain serine protease involved in moulting in the silkworm, Bombyx mori: cloning, characterization, expression patterns and functional analysis.

    Science.gov (United States)

    Liu, H-W; Wang, L-L; Meng, Z; Tang, X; Li, Y-S; Xia, Q-Y; Zhao, P

    2017-10-01

    Clip domain serine proteases (CLIPs), characterized by one or more conserved clip domains, are essential components of extracellular signalling cascades in various biological processes, especially in innate immunity and the embryonic development of insects. Additionally, CLIPs may have additional non-immune functions in insect development. In the present study, the clip domain serine protease gene Bombyx mori serine protease 95 (BmSP95), which encodes a 527-residue protein, was cloned from the integument of B. mori. Bioinformatics analysis indicated that BmSP95 is a typical CLIP of the subfamily D and possesses a clip domain at the N terminus, a trypsin-like serine protease (tryp_spc) domain at the C terminus and a conserved proline-rich motif between these two domains. At the transcriptional level, BmSP95 is expressed in the integument during moulting and metamorphosis, and the expression pattern is consistent with the fluctuating 20-hydroxyecdysone (20E) titre in B. mori. At the translational level, BmSP95 protein is synthesized in the epidermal cells, secreted as a zymogen and activated in the moulting fluid. Immunofluorescence revealed that BmSP95 is distributed into the old endocuticle in the moulting stage. The expression of BmSP95 was upregulated by 20E. Moreover, expression of BmSP95 was downregulated by pathogen infection. RNA interference-mediated silencing of BmSP95 led to delayed moulting from pupa to moth. These results suggest that BmSP95 is involved in integument remodelling during moulting and metamorphosis. © 2017 The Royal Entomological Society.

  19. Theobromine increases NAD⁺/Sirt-1 activity and protects the kidney under diabetic conditions.

    Science.gov (United States)

    Papadimitriou, Alexandros; Silva, Kamila C; Peixoto, Elisa B M I; Borges, Cynthia M; Lopes de Faria, Jacqueline M; Lopes de Faria, José B

    2015-02-01

    Reduction in sirtuin 1 (Sirt-1) is associated with extracellular matrix (ECM) accumulation in the diabetic kidney. Theobromine may reduce kidney ECM accumulation in diabetic rats. In the current study, we aimed to unravel, under diabetic conditions, the mechanism of kidney ECM accumulation induced by a reduction in Sirt-1 and the effect of theobromine in these events. In vitro, we used immortalized human mesangial cells (iHMCs) exposed to high glucose (HG; 30 mM), with or without small interfering RNA for NOX4 and Sirt-1. In vivo, spontaneously hypertensive rats (SHR) were rendered diabetic by means of streptozotocin and studied after 12 wk. The effects of treatment with theobromine were investigated under both conditions. HG leads to a decrease in Sirt-1 activity and NAD(+) levels in iHMCs. Sirt-1 activity could be reestablished by treatment with NAD(+), silencing NOX4, and poly (ADP-ribose) polymerase-1 (PARP-1) blockade, or with theobromine. HG also leads to a low AMP/ATP ratio, acetylation of SMAD3, and increased collagen IV, which is prevented by theobromine. Sirt-1 or AMPK blockade abolished these effects of theobromine. In diabetic SHR, theobromine prevented increases in albuminuria and kidney collagen IV, reduced AMPK, elevated NADPH oxidase activity and PARP-1, and reduced NAD(+) levels and Sirt-1 activity. These results suggest that in diabetes mellitus, Sirt-1 activity is reduced by PARP-1 activation and NAD(+) depletion due to low AMPK, which increases NOX4 expression, leading to ECM accumulation mediated by transforming growth factor (TGF)-β1 signaling. It is suggested that Sirt-1 activation by theobromine may have therapeutic potential for diabetic nephropathy. Copyright © 2015 the American Physiological Society.

  20. Kidney transplant

    Science.gov (United States)

    ... always take your medicine as directed. Alternative Names Renal transplant; Transplant - kidney Patient Instructions Kidney removal - discharge Images Kidney anatomy Kidney - blood and urine flow Kidneys Kidney transplant - ...

  1. Risk for cancer in living kidney donors and recipients.

    Science.gov (United States)

    Wang, Min; Zhang, Huai; Zhou, Dan; Qiao, Yong-Chao; Pan, Yan-Hong; Wang, Yan-Chao; Zhao, Hai-Lu

    2018-03-01

    Malignancy following renal transplantation remains inconsistent with the reported safety of kidney donation during the long-term follow-up. We conducted searches of the published literature which included healthy participants, recipients, living kidney donors (LKDs), and the availability of outcome data for malignancy. Eight from 938 potentially relevant studies were analyzed by means of fixed-effects model or random-effects model, as appropriately. In 48,950 participants, the follow-up range was 18 months to 20 years, and the mean age of the subjects was approximately 41 years. The incidence rate with 95% confidence interval (CI) for malignancy after kidney transplantation was 0.03 (0.01-0.05) in recipients and 0.03 (0.1-0.07) in LKDs, giving a pooled incidence rate of 0.03 (95% CI 0.02-0.04). LKDs contrasted nondonors by the overall odds ratio and 95% CI for total cancer of 2.80 (2.69-2.92). Kidney transplantation was associated with an increased risk of cancer during a long-term follow-up. Long-term risk for cancer in LKDs and kidney recipients should be monitored.

  2. Cordyceps cicadae extracts ameliorate renal malfunction in a remnant kidney model*

    Science.gov (United States)

    Zhu, Rong; Chen, Yi-ping; Deng, Yue-yi; Zheng, Rong; Zhong, Yi-fei; Wang, Lin; Du, Lan-ping

    2011-01-01

    Background and Objectives: Chronic kidney disease (CKD) is a growing public health problem with an urgent need for new pharmacological agents. Cordyceps cicadae is widely used in traditional Chinese medicine (TCM) and has potential renoprotective benefits. The current study aimed to determine any scientific evidence to support its clinical use. Methods: We analyzed the potential of two kinds of C. cicadae extract, total extract (TE) and acetic ether extract (AE), in treating kidney disease simulated by a subtotal nephrectomy (SNx) model. Sprague-Dawley rats were divided randomly into seven groups: sham-operated group, vehicle-treated SNx, Cozaar, 2 g/(kg∙d) TE SNx, 1 g/(kg∙d) TE SNx, 92 mg/(kg∙d) AE SNx, and 46 mg/(kg∙d) AE SNx. Renal injury was monitored using urine and serum analyses, and hematoxylin and eosin (HE) and periodic acid-Schiff (PAS) stainings were used to analyze the level of fibrosis. The expression of type IV collagen (Col IV), fibronectin (FN), transforming growth factor-β1 (TGF-β1), and connective tissue growth factor (CTGF) was detected by immunohistochemistry. Results: Renal injury, reflected in urine and serum analyses, and pathological changes induced by SNx were attenuated by TE and AE intervention. The depositions of Col IV and FN were also decreased by the treatments and were accompanied by reduced expression of TGF-β1 and CTGF. In some respects, 2 g/(kg∙d) of TE produced better effects than Cozaar. Conclusions: For the first time, we have shown that C. cicadae may inhibit renal fibrosis in vivo through the TGF-β1/CTGF pathway. Therefore, we conclude that the use of C. cicadae could provide a rational strategy for combating renal fibrosis. PMID:22135152

  3. Initial experience of percutaneous treatment of mitral regurgitation with MitraClip® therapy in Spain.

    Science.gov (United States)

    Carrasco-Chinchilla, Fernando; Arzamendi, Dabit; Romero, Miguel; Gimeno de Carlos, Federico; Alonso-Briales, Juan Horacio; Li, Chi-Hion; Mesa, Maria Dolores; Arnold, Roman; Serrador Frutos, Ana María; Pan, Manuel; Roig, Eulalia; Rodríguez-Bailón, Isabel; de la Fuente Galán, Luis; Hernández, José María; Serra, Antonio; Suárez de Lezo, José

    2014-12-01

    Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  4. Nuclear factor κB inhibitor BAY 11-7082 suppresses oxidative stress induced by endothelin-1 (ET-1) in rat kidney.

    Science.gov (United States)

    Kowalczyk, Agata; Kołodziejczyk, Michał; Gorąca, Anna

    2015-12-31

    The aim of the study was to evaluate the effect of BAY 11-7082, an NF-κB inhibitor, on basal and ET-1-induced production of reactive oxygen species (ROS), TNF-α and p65 protein in rat kidney. The experimental animals were divided into five groups (n=7) receiving: 1) saline (control); 2 and 3) ET-1 in a dose of 3 μg/kg body weight (b.w.) or 12.5 μg/kg b.w.; 4) BAY 11-7082 (10 mg/kg b.w.); 5) BAY 11-7082 (10 mg/kg b.w.) and ET-1 (12.5 μg/kg b.w.), respectively. In kidney homogenates the concentration of thiobarbituric acid reactive substances (TBARS), H2O2, TNF-α, p65 protein and GSH/GSSG ratio were determined. ET-1 resulted in a dose-dependent increase in TBARS and hydrogen peroxide (H2O2) levels, and a decrease in GSH/GSSG ratio when compared to the controls. BAY 11-7082 administered 1 h before ET-1 administration at a dose of 12.5 μg/kg resulted in a decrease (PET-1 groups. The level of TNF-α was increased (PET-1, while BAY 11-7082 reduced the TNF-α level (PET-1 induced oxidative stress in kidney tissue. These actions of BAY 11-7082 may result from reduced activity of NF-κB signaling pathways. Inhibition of the NF-κB pathway may be a promising strategy for preventing the progression of kidney damage.

  5. ET-1 deletion from endothelial cells protects the kidney during the extension phase of ischemia/reperfusion injury

    Energy Technology Data Exchange (ETDEWEB)

    Arfian, Nur [Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe (Japan); Emoto, Noriaki, E-mail: emoto@med.kobe-u.ac.jp [Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe (Japan); Department of Clinical Pharmacy, Kobe Pharmaceutical University, Kobe (Japan); Vignon-Zellweger, Nicolas; Nakayama, Kazuhiko; Yagi, Keiko [Department of Clinical Pharmacy, Kobe Pharmaceutical University, Kobe (Japan); Hirata, Ken-ichi [Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe (Japan)

    2012-08-24

    Highlights: Black-Right-Pointing-Pointer Ischemia/reperfusion injury (IRI) induced increased endothelin-1 (ET-1) expression. Black-Right-Pointing-Pointer IRI was accompanied by tubular injury and remodeling of renal arteries. Black-Right-Pointing-Pointer IRI increased oxidative stress and inflammation. Black-Right-Pointing-Pointer Genetic suppression of ET-1 in endothelial cells attenuates IRI in the kidney. Black-Right-Pointing-Pointer The mechanisms include the inhibition of oxidative stress and inflammation. -- Abstract: Background: The prognosis of patients after acute kidney injury (AKI) is poor and treatment is limited. AKI is mainly caused by renal ischemia/reperfusion injury (IRI). During the extension phase of IRI, endothelial damage may participate in ischemia and inflammation. Endothelin-1 (ET-1) which is mostly secreted by endothelial cells is an important actor of IRI, particularly through its strong vasoconstrictive properties. We aimed to analyze the specific role of ET-1 from the endothelial cells in AKI. Methods: We used mice lacking ET-1 in the vascular endothelial cells (VEETKO). We induced IRI in VEETKO mice and wild type controls by clamping both kidneys for 30 min. Sham operated mice were used as controls. Mice were sacrificed one day after IRI in order to investigate the extension phase of IRI. Kidney function was assessed based on serum creatinine concentration. Levels of expression of ET-1, its receptor ET{sub A}, protein kinase C, eNOS, E-Cadherin and inflammation markers were evaluated by real time PCR or western blot. Tubular injury was scored on periodic acid Schiff stained kidney preparations. Lumen and wall area of small intrarenal arteries were measured on kidney slices stained for alpha smooth muscle cell actin. Oxidative stress, macrophage infiltration and cell proliferation was evaluated on slices stained for 8-hydroxy-2 Prime -deoxyguanosine, F4/80 and PCNA, respectively. Results: IRI induced kidney failure and increased ET-1 and

  6. Temporo-sylvian anastomosis and aneurysm clipping in a case of left M1 aneurysm with progressive evolution after initial embolization; Case report

    Directory of Open Access Journals (Sweden)

    Ion Georgiana

    2015-06-01

    Full Text Available A giant unrupted middle cerebral artery aneurysm partially thrombosed, previously endovascularly treated after a mild right hemiparesis remitted. After 12 months, in routine check we discovered a reperfusion of the aneurysm and decide ECIC bypass and clipping, with a good outcome

  7. Influence of socioeconomic status on allograft and patient survival following kidney transplantation.

    Science.gov (United States)

    Ward, Frank L; O'Kelly, Patrick; Donohue, Fionnuala; ÓhAiseadha, Coilin; Haase, Trutz; Pratschke, Jonathan; deFreitas, Declan G; Johnson, Howard; Conlon, Peter J; O'Seaghdha, Conall M

    2015-06-01

    Whether socioeconomic status confers worse outcomes after kidney transplantation is unknown. Its influence on allograft and patient survival following kidney transplantation in Ireland was examined. A retrospective, observational cohort study of adult deceased-donor first kidney transplant recipients from 1990 to 2009 was performed. Those with a valid Irish postal address were assigned a socioeconomic status score based on the Pobal Hasse-Pratschke deprivation index and compared in quartiles. Cox proportional hazards models and Kaplan-Meier survival analysis were used to investigate any significant association of socioeconomic status with patient and allograft outcomes. A total of 1944 eligible kidney transplant recipients were identified. The median follow-up time was 8.2 years (interquartile range 4.4-13.3 years). Socioeconomic status was not associated with uncensored or death-censored allograft survival (hazard ratio (HR) 1.0, 95% confidence interval (CI) 0.99-1.00, P = 0.33 and HR 1.0, 95% CI 0.99-1.00, P = 0.37, respectively). Patient survival was not associated with socioeconomic status quartile (HR 1.0, 95% CI 0.93-1.08, P = 0.88). There was no significant difference among quartiles for uncensored or death-censored allograft survival at 5 and 10 years. There was no socioeconomic disparity in allograft or patient outcomes following kidney transplantation, which may be partly attributable to the Irish healthcare model. This may give further impetus to calls in other jurisdictions for universal healthcare and medication coverage for kidney transplant recipients. © 2015 Asian Pacific Society of Nephrology.

  8. Establishing a protocol for element determination in human nail clippings by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2011-01-01

    Human nail samples have been analyzed to evaluate occupational exposure, nutritional status and to diagnose certain diseases. However, sampling and washing protocols for nail analyses vary from study to study not allowing comparisons between studies. One of the difficulties in analyzing nail samples is to eliminate only surface contamination without removing elements of interest in this tissue. In the present study, a protocol was defined in order to obtain reliable results of element concentrations in human nail clippings. Nail clippings collected from all 10 fingers or toes were previously pre cleaned using an ethyl alcohol solution to eliminate microbes. Then, the clippings were cut in small pieces and submitted to different reagents for washing by shaking. Neutron activation analysis (NAA) was applied for nail samples analysis which consisted of irradiating aliquots of samples together with synthetic elemental standards in the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Comparisons made between the results obtained for nails submitted to different reagents for cleaning indicated that the procedure using acetone and Triton X100 solution is more effective than that of nitric acid solution. Analyses in triplicates of a nail sample indicated results with relative standard deviations lower than 15% for most of elements, showing the homogeneity of the prepared sample. Qualitative analyses of different nail polishes showed that the presence of elements determined in the present study is negligible in these products. Quality control of the analytical results indicated that the applied NAA procedure is adequate for human nail analysis. (author)

  9. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. 78 FR 78319 - Media Bureau Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips

    Science.gov (United States)

    2013-12-26

    ... Video Programming: Implementation of the Twenty-First Century Communications and Video Accessibility Act..., pursuant to the Twenty-First Century Communications and Video Accessibility Act of 2010 (``CVAA''),\\2\\ the... clips, especially news clips.\\8\\ The Commission stated that if it finds that consumers who are deaf or...

  11. Effect of gender on results of percutaneous edge-to-edge mitral valve repair with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Winter, Reidar

    2015-01-01

    ≤II in 73.1% of men vs 74.2% of women, p = 0.912). After a mean follow-up period of 16.1 ± 11.1 months, no difference was found between groups in the incidence of death or admission for heart failure (log-rank p = 0.798). In conclusion, MitraClip implantation seems to be an equally safe and effective...

  12. New susceptibility loci associated with kidney disease in type 1 diabetes

    DEFF Research Database (Denmark)

    Sandholm, Niina; Salem, Rany M; McKnight, Amy Jayne

    2012-01-01

    Diabetic kidney disease, or diabetic nephropathy (DN), is a major complication of diabetes and the leading cause of end-stage renal disease (ESRD) that requires dialysis treatment or kidney transplantation. In addition to the decrease in the quality of life, DN accounts for a large proportion...... mechanisms behind the disease remain poorly understood, and current therapeutic strategies rarely result in reversal of DN. In the GEnetics of Nephropathy: an International Effort (GENIE) consortium, we have undertaken a meta-analysis of genome-wide association studies (GWAS) of T1D DN comprising ~2...... SNP in the ERBB4 gene (rs7588550, P = 2.1 × 10(-7)), a gene with type 2 diabetes DN differential expression and in the same intron as a variant with cis-eQTL expression of ERBB4. All these detected associations represent new signals in the pathogenesis of DN....

  13. Alemtuzumab (Campath-1H) in kidney transplantation.

    Science.gov (United States)

    Ciancio, G; Burke, G W

    2008-01-01

    Kidney transplantation has become the treatment of choice for both the quality of life and survival in patients with end-stage renal disease (ESRD). However, the immunosuppressive regimen which allows optimal kidney transplant outcome remains elusive. One of the more promising induction agents, Alemtuzumab, was introduced to kidney transplantation by Calne in the late 1990s with low dose cyclosporine A monotherapy, with the hope of establishing 'prope' or near tolerance. Subsequent pilot studies with Alemtuzumab alone or monotherapy (DSG, Rapa) demonstrated high rates of acute rejection (AR) along with occasional humoral components that lead to abandoning the concept of Alemtuzumab as a 'magic bullet' to achieve tolerance, prope or otherwise. A number of programs (including our own) has since modified maintenance immunosuppression using low dose tacrolimus, and shown acceptable rates of AR, with relatively low incidence of viral infection and lymphoproliferative disorders along with cost benefit. However, there are only three prospective, randomized studies which are small with one year or less follow-up, and most published series utilize historical control groups with relatively short follow-up. As extrapolation from short-term data is far from secure, long-term, prospective, randomized studies with Alemtuzumab will be necessary to determine the optimal immunosuppressive regimen.

  14. Peptides-Derived from Thai Rice Bran Improves Endothelial Function in 2K-1C Renovascular Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Orachorn Boonla

    2015-07-01

    Full Text Available In recent years, a number of studies have investigated complementary medical approaches to the treatment of hypertension using dietary supplements. Rice bran protein hydrolysates extracted from rice is a rich source of bioactive peptides. The present study aimed to investigate the vasorelaxation and antihypertensive effects of peptides-derived from rice bran protein hydrolysates (RBP in a rat model of two kidney-one clip (2K-1C renovascular hypertension. 2K-1C hypertension was induced in male Sprague-Dawley rats by placing a silver clip around the left renal artery, whereas sham-operated rats were served as controls. 2K-1C and sham-operated rats were intragastrically administered with RBP (50 mg kg−1 or 100 mg kg−1 or distilled water continuously for six weeks. We observed that RBP augmented endothelium-dependent vasorelaxation in all animals. Administration of RBP to 2K-1C rats significantly reduced blood pressure and decreased peripheral vascular resistance compared to the sham operated controls (p < 0.05. Restoration of normal endothelial function and blood pressure was associated with reduced plasma angiotensin converting enzyme (ACE, decreased superoxide formation, reduced plasma malondialdehyde and increased plasma nitrate/nitrite (p < 0.05. Up-regulation of eNOS protein and down-regulation of p47phox protein were found in 2K-1C hypertensive rats-treated with RBP. Our results suggest that RBP possesses antihypertensive properties which are mainly due to the inhibition of ACE, and its vasodilatory and antioxidant activity.

  15. Volume effect on the radiation injury of rat kidney

    International Nuclear Information System (INIS)

    Lo, Y.-C.; Kutcher, Gerald J.; Ling, Clifton C.

    1996-01-01

    Purpose: To minimize the likelihood of radiation-induced kidney injury in treating tumors, the relationship of tolerance dose and irradiated volume of kidney should be known. We have used a rat model to determine the dose-response relationship when various volumes of the kidney are irradiated. Methods and Materials: Anesthetized adult male rats (CD, 10-12 week old) were irradiated with 250 KV x-rays. The kidney was exteriorized and placed in a jig designed to shield all other tissues. Graded single doses were delivered to each of four volumes: 1/4V (half of one kidney), 1/2V (one whole kidney, or half of each kidney), 3/4V (one and a half kidneys) and 1V, where V is the volume of both kidneys. In addition, to compare radiation injury and surgery, partial nephrectomy was performed for 1/4V, 1/2V and 3/4V. Four to sixteen rats were used for each dose-volume point. The rats have been followed up for 540 days. The endpoints for the damage were: lethality, anemia, glomerular filtration rate, effective renal flow, and histology. Results: We found that: (1) There was a threshold volume for radiation damage; injury did not occur if the volume irradiated was ≤ 1/2V, depending on the endpoints. (2) Median survival times did not depend on the dose when a small volume (i.e., 1/4V or 1/2V) was irradiated. (3) The LD 50 (and the 95% confidence limits) at 450 days were 11.35 (8.08 to 12.13) Gy for 1V, 12.38 (11.08 to 13.40) Gy for 3/4V, 21.16 (17.21 to 26.56) Gy for 1/2V, and 28.80 (21.11 to 65.00) Gy for 1/4V. (4) The ED 50 for animals with hematocrit level ≤0.36 at 365 days was 10.98 (4.96 to 13.67) Gy for 1.0V, and 13.82 (6.16 to 17.97) Gy for 3/4V. For 1/2V, only the 80% confidence limits could be derived, giving ED 50 +40.14 (27.98 to ∞) Gy. (5) The results for all other endpoints were similar to those for hematocrit. (6) The dose response was the same whether to half of each kidney or one whole kidney was irradiated. (7) While the threshold volume for radiation injury

  16. The metabolism of parathyroid hormone in kidney

    International Nuclear Information System (INIS)

    Hanao, Yasuhisa

    1978-01-01

    In order to investigate the mechanism and localization of parathyroid hormone (PTH), the degradation and the effects of calcium ion to PTH degradation in kidney, bovine PTH (b-PTH 1 - 84) and its synthetic N-terminal peptide (b-PTH 1 - 34) labeled with 125 I by Chloramine T methods ( 125 I-b-PTH 1 - 84 and 125 I-b-PTH 1 - 34) or labeled with horse radish peroxidase ( 125 I-POX-b-PTH 1 - 84 and 125 I-POX-bPTH 1-34) were used to study the disappearance from the blood stream and degradation and retention in the kidney after intravenous injections in male Wistar rats, weighing approximately 350 - 450 g. Degradation of PTH was studied in vitro, using isolated cells and homogenates of the kidney, and the effects of calcium ion to PTH degradation were furthermore studied, using our kidney perfusion system. PTH labeled with 125 I and POX was less degraded by the kidney than PTH labeled with 125 I alone. PTH 1 - 34 was more delayed in blood stream than PTH 1 - 84. Isolated intact kidney cells degrade PTH less efficiently than homogenates, indicating the prominance of microsomal degradative system in the kidney. The degradation of PTH in kidney was supposed to be controlled by calcium ion in our kidney perfusion system. (author)

  17. Trace elements in nail polish as a source of contamination of nail clippings when used in epidemiological studies

    International Nuclear Information System (INIS)

    Favaro, P.C.; Bode, P.; De Nadai Fernandes, E.A.

    2005-01-01

    Trace elements were determined in 27 brands of nail polish using INAA so as to estimate the impact of nail polish remainders when using (finger, toe) nail clippings as a bioindicator for epidemiological studies. Fe was found to be present up to almost 1.7% in one brand. No unambiguous correlation between trace elements and color was established, though transparent polish has the lowest trace element concentrations. An estimate of the maximum effect (no removal of the paint) indicates that over-estimates of some trace element levels in nail with more than 200.000% may occur. If nail clippings will be used to study trace elements, very high demands have to be set to the efficiency and selectivity of the cleaning procedure. (author)

  18. Optical coherence tomography (OCT) of a murine model of chronic kidney disease

    Science.gov (United States)

    Wang, Hsing-Wen; Guo, Hengchang; Andrews, Peter M.; Anderson, Erik; Chen, Y.

    2015-03-01

    Chronic Kidney Disease (CKD) is characterized by a progressive loss in renal function over time. Pathology can provide valuable insights into the progression of CKD by analyzing the status of glomeruli and the uriniferous tubules over time. Optical coherence tomography (OCT) is a new procedure that can analyze the microscopic structure of the kidney in a non-invasive manner. This is especially important because there are significant artifacts associated with excision biopsies and immersion fixation procedures. Recently, we have shown that OCT can provide real time images of kidney microstructure and Doppler OCT (DOCT) can image glomerular renal blood flow in vivo without administrating exogenous contrast agents. In this study, we used OCT to evaluate CKD in a model induced by intravenous Adriamycin injection into Munich-Wistar rats. We evaluated tubular density and tubular diameter from OCT images at several post- Adriamycin induction time points and compared them with conventional light microscopic histological imaging. Proteinurea and serum creatinine were used as physiological markers of the extent of CKD. Preliminary OCT results revealed changes in tubular density due to tubular necrosis and interstitial fibrosis within the first 4 weeks following Adriamycin injection. From week 4 to 8 after Adriamycin induction, changes in tubular density and diameter occurred due to both tubular loss and tubular dilation. The results suggest OCT can provide additional information about kidney histopathology in CKD. DOCT revealed reduced blood flow in some glomeruli probably as a consequence of focal glomerularsclerosis.

  19. Survival Prediction in Patients Undergoing Open-Heart Mitral Valve Operation After Previous Failed MitraClip Procedures.

    Science.gov (United States)

    Geidel, Stephan; Wohlmuth, Peter; Schmoeckel, Michael

    2016-03-01

    The objective of this study was to analyze the results of open heart mitral valve operations for survival prediction in patients with previously unsuccessful MitraClip procedures. Thirty-three consecutive patients who underwent mitral valve surgery in our institution were studied. At a median of 41 days, they had previously undergone one to five futile MitraClip implantations. At the time of their operations, patients were 72.6 ± 10.3 years old, and the calculated risk, using the European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, was a median of 26.5%. Individual outcomes were recorded, and all patients were monitored postoperatively. Thirty-day mortality was 9.1%, and the overall survival at 2.2 years was 60.6%. Seven cardiac-related and six noncardiac deaths occurred. Univariate survival regression models demonstrated a significant influence of the following variables on survival: EuroSCORE II (p = 0.0022), preoperative left ventricular end-diastolic dimension (p = 0.0052), left ventricular ejection fraction (p = 0.0249), coronary artery disease (p = 0.0385), and severe pulmonary hypertension (p = 0.0431). Survivors showed considerable improvements in their New York Heart Association class (p < 0.0001), left ventricular ejection fraction (p = 0.0080), grade of mitral regurgitation (p = 0.0350), and mitral valve area (p = 0.0486). Survival after mitral repair was not superior to survival after replacement. Indications for surgery after failed MitraClip procedures must be considered with the greatest of care. Variables predicting postoperative survival should be taken into account regarding the difficult decision as to whether to operate or not. Our data suggest that replacement of the pretreated mitral valve is probably the more reasonable concept rather than complex repairs. When the EuroSCORE II at the time of surgery exceeds 30%, conservative therapy is advisable. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc

  20. Do medical students watch video clips in eLearning and do these facilitate learning?

    Science.gov (United States)

    Romanov, Kalle; Nevgi, Anne

    2007-06-01

    There is controversial evidence of the impact of individual learning style on students' performance in computer-aided learning. We assessed the association between the use of multimedia materials, such as video clips, and collaborative communication tools with learning outcome among medical students. One hundred and twenty-one third-year medical students attended a course in medical informatics (0.7 credits) consisting of lectures, small group sessions and eLearning material. The eLearning material contained six learning modules with integrated video clips and collaborative learning tools in WebCT. Learning outcome was measured with a course exam. Approximately two-thirds of students (68.6%) viewed two or more videos. Female students were significantly more active video-watchers. No significant associations were found between video-watching and self-test scores or the time used in eLearning. Video-watchers were more active in WebCT; they loaded more pages and more actively participated in discussion forums. Video-watching was associated with a better course grade. Students who watched video clips were more active in using collaborative eLearning tools and achieved higher course grades.

  1. Better recovery of kidney function in patients with de novo chronic kidney disease after partial nephrectomy compared with those with pre-existing chronic kidney disease.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Hashimoto, Yasunobu; Yoshida, Kazuhiko; Tanabe, Kazunari

    2014-06-01

    We compared kidney functional recovery between patients with pre-existing chronic kidney disease, those with de novo chronic kidney disease and those with normal kidney function, after partial nephrectomy. A total of 311 patients who underwent partial nephrectomy at Tokyo Women's Medical University Hospital, Tokyo, Japan, between January 2004 and July 2011 with sufficient kidney functional data participated in the study. Patients with pre-existing chronic kidney disease (group1: 78 patients) were defined as those with estimated glomerular filtration rate under 60 mL/min/m(2) before partial nephrectomy. Patients with de novo chronic kidney disease (group 2: 49) were defined as those with estimated glomerular filtration rate over 60 mL/min/m(2) before surgery and who developed estimated glomerular filtration rate under 60 mL/min/m(2) 3 months after partial nephrectomy. Normal patients (group 3: 184) were defined as those with estimated glomerular filtration rate over 60 mL/min/m(2) both before and after partial nephrectomy. Group 1 was associated with older age and higher comorbidity, including hypertension and diabetes mellitus, compared with other groups. R.E.N.A.L. score was not significantly different between the groups. Although the percent change of estimated glomerular filtration rate between the preoperative period and 3 months after partial nephrectomy in group 2 was significantly decreased compared with that in other groups (group 1: -6.8%, group 2: -18%, group 3: -7.3%), the renal functional recovery between 3 and 12 months after partial nephrectomy in group 2 was better than that in other groups (group 1: -0.5%, group 2: 5.6%, group 3: -0.4%). Patients with de novo chronic kidney disease had better kidney functional recovery than the other two groups, which might suggest that they were surgically assaulted and developed chronic kidney disease in the early postoperative period, and were essentially different from those with pre-existing chronic kidney

  2. Dual Kidney Allocation Score: A Novel Algorithm Utilizing Expanded Donor Criteria for the Allocation of Dual Kidneys in Adults.

    Science.gov (United States)

    Johnson, Adam P; Price, Thea P; Lieby, Benjamin; Doria, Cataldo

    2016-09-08

    BACKGROUND Dual kidney transplantation (DKT) of expanded-criteria donors is a cost-intensive procedure that aims to increase the pool of available deceased organ donors and has demonstrated equivalent outcomes to expanded-criteria single kidney transplantation (eSKT). The objective of this study was to develop an allocation score based on predicted graft survival from historical dual and single kidney donors. MATERIAL AND METHODS We analyzed United Network for Organ Sharing (UNOS) data for 1547 DKT and 26 381 eSKT performed between January 1994 and September 2013. We utilized multivariable Cox regression to identify variables independently associated with graft survival in dual and single kidney transplantations. We then derived a weighted multivariable product score from calculated hazard ratios to model the benefit of transplantation as dual kidneys. RESULTS Of 36 donor variables known at the time of listing, 13 were significantly associated with graft survival. The derived dual allocation score demonstrated good internal validity with strong correlation to improved survival in dual kidney transplants. Donors with scores less than 2.1 transplanted as dual kidneys had a worsened median survival of 594 days (24%, p-value 0.031) and donors with scores greater than 3.9 had improved median survival of 1107 days (71%, p-value 0.002). There were 17 733 eSKT (67%) and 1051 DKT (67%) with scores in between these values and no differences in survival (p-values 0.676 and 0.185). CONCLUSIONS We have derived a dual kidney allocation score (DKAS) with good internal validity. Future prospective studies will be required to demonstrate external validity, but this score may help to standardize organ allocation for dual kidney transplantation.

  3. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  4. Revisiting double kidney transplantation: two kidneys provide better graft survival than one.

    Science.gov (United States)

    Cruzado, J M; Fernandez, L; Riera, L; Bestard, O; Carrera, M; Torras, J; Gil Vernet, S; Melilli, E; Ngango, L; Grinyó, J M

    2011-01-01

    Double kidney transplantation is an accepted strategy to increase the donor pool. Regarding older donor kidneys, protocols for deciding to perform a dual or a single transplantation are mainly based on preimplantation biopsies. The aim of our study was to evaluate the long-term graft and patient survivals of our "Dual Kidney Transplant program." Patients who lost one of their grafts peritransplantation were used as controls. A total of 203 patients underwent kidney transplantation from December 1996 to January 2008 in our "old for old" renal transplantation program. We excluded 21 patients because of a nonfunctioning kidney, hyperacute rejection, or patient death with a functioning graft within the first month. Seventy-nine among 182 kidney transplantation the "old for old" program were dual kidney transplantation (DKT). Fifteen of 79 patients lost one of their kidney grafts (the uninephrectomized (UNX) UNX group). At 1 year, renal function was lower and proteinuria greater among the UNX than the DKT group. Patient survival was similar in both groups. However, death-censored graft survival was lower in UNX than DKT patients. The 5-year graft survival rate was 70% in UNX versus 93% in DKT cohorts (P = .04). In conclusion, taking into account the kidney shortage, our results may question whether the excellent transplant outcomes with DKT counter balance the reduced donor pool obviating acceptable transplant outcomes for more patients with single kidney transplantation. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Improving NAVFAC's total quality management of construction drawings with CLIPS

    Science.gov (United States)

    Antelman, Albert

    1991-01-01

    A diagnostic expert system to improve the quality of Naval Facilities Engineering Command (NAVFAC) construction drawings and specification is described. C Language Integrated Production System (CLIPS) and computer aided design layering standards are used in an expert system to check and coordinate construction drawings and specifications to eliminate errors and omissions.

  6. Association Between Newborn Metabolic Profiles and Pediatric Kidney Disease

    Directory of Open Access Journals (Sweden)

    Manish M. Sood

    2018-05-01

    Full Text Available Introduction: Metabolomics offers considerable promise in early disease detection. We set out to test the hypothesis that routine newborn metabolic profiles at birth, obtained through screening for inborn errors of metabolism, would be associated with kidney disease and add incremental information to known clinical risk factors. Methods: We conducted a population-level cohort study in Ontario, Canada, using metabolic profiles from 1,288,905 newborns from 2006 to 2015. The primary outcome was chronic kidney disease (CKD or dialysis. Individual metabolites and their ratio combinations were examined by logistic regression after adjustment for established risk factors for kidney disease and incremental risk prediction measured. Results: CKD occurred in 2086 (0.16%, median time 612 days and dialysis in 641 (0.05%, median time 99 days infants and children. Individual metabolites consisted of amino acids, acylcarnitines, markers of fatty acid oxidation, and others. Base models incorporating clinical risk factors only provided c-statistics of 0.61 for CKD and 0.70 for dialysis. The addition of identified metabolites to risk prediciton models resulted in significant incremental improvement in the performance of both models (CKD model: c-statistic 0.66 NRI 0.36 IDI 0.04, dialysis model: c-statistic 0.77 NRI 0.57 IDI 0.09. This was consistent after internal validation using bootstrapping and a sensitivity analysis excluding outcomes within the first 30 days. Conclusion: Routinely collected screening metabolites at birth are associated with CKD and the need for dialytic therapies in infants and children, and add incremental information to traditional clinical risk factors. Keywords: chronic kidney disease, dialysis, end-stage kidney disease, metabolomics, newborn screening, pediatric, renal failure

  7. Cadmium and other heavy metal concentrations in bovine kidneys in the Republic of Ireland

    Energy Technology Data Exchange (ETDEWEB)

    Canty, Mary J., E-mail: mary.canty@agriculture.gov.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland); Department of Agriculture, Food and the Marine, Backweston Campus, Celbridge, Co. Kildare (Ireland); Scanlon, Aiden, E-mail: aiden.scanlon@agriculture.gov.ie [Department of Agriculture, Food and the Marine, Agriculture House, Kildare St, Dublin 2 (Ireland); Collins, Daniel M., E-mail: daniel.collins@ucd.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland); McGrath, Guy, E-mail: guy.mcgrath@ucd.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland); Clegg, Tracy A., E-mail: tracy.clegg@ucd.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland); Lane, Elizabeth, E-mail: elizabeth.lane@agriculture.gov.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland); Department of Agriculture, Food and the Marine, Backweston Campus, Celbridge, Co. Kildare (Ireland); Sheridan, Michael K., E-mail: michael.sheridan@agriculture.gov.ie [Department of Agriculture, Food and the Marine, Agriculture House, Kildare St, Dublin 2 (Ireland); More, Simon J., E-mail: simon.more@ucd.ie [Centre for Veterinary Epidemiology and Risk Analysis (CVERA), UCD School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4 (Ireland)

    2014-07-01

    In Ireland, an estimated 15% of Irish soils exceed the EU threshold limit for soil Cd of 1 mg/kg. The aim was to determine the concentrations of Cd and other heavy metals (As, Hg and Pb) in kidneys collected from cattle at slaughter. Systematic sampling of eligible animals (animals that were born and reared until slaughter in the same Irish county) at the time of slaughter was conducted, until a threshold number of animals from all 26 counties and 6 age categories was reached. A predictive surface of soil Cd was generated, by kriging the Cd values of 1310 previously reported soil samples. A linear regression weighted model was developed to model kidney Cd concentration, using the risk factors of age, sex, breed, province and estimated soil Cd concentration. Kidney Cd (n = 393) concentrations varied between 0.040 and 8.630 mg/kg wet weight; while concentrations of As, Hg and Pb were low. The estimated weighted proportion of animals with a high (≥ 1 mg/kg) kidney Cd concentration was 11.25% (95% CI: 8.63–14.53%). Key predictors for high kidney Cd concentration were soil Cd, animal age and province. At a soil Cd concentration of 1.5 mg/kg, it was predicted that an age threshold to avoid exceeding a kidney Cd concentration of 1 mg/kg in most animals would be ∼ 3 y in Connacht, > 4 y in Ulster, and > 5 y in Leinster and Munster. In naturally occurring areas of high Cd levels in soils in Ireland, the Cd level in bovine kidneys can exceed the current EU ML of 1 mg/kg in older animals. Kidneys of most cattle under three years of age will conform with EU requirements. - Highlights: • An estimated 15% of Irish soils exceed the EU Cd threshold limit of 1 mg/kg. • 11.3% of cattle had kidney Cd concentrations in excess of the EU ML of 1 mg/kg. • Age, soil Cd concentrations and region were key predictors of elevated kidney Cd. • Kidneys of most Irish cattle under three years of age will conform with EU requirements.

  8. Unilateral Partial Nephrectomy with Warm Ischemia Results in Acute Hypoxia Inducible Factor 1-Alpha (HIF-1α and Toll-Like Receptor 4 (TLR4 Overexpression in a Porcine Model.

    Directory of Open Access Journals (Sweden)

    Zhiyong Zhang

    Full Text Available Ischemia/reperfusion (I/R during partial nephrectomy (PN contributes to acute kidney injury (AKI, which is inaccurately assessed using existent clinical markers of renal function. We evaluated I/R-related changes in expression in hypoxia inducible factor 1α (HIF-1α and toll-like receptor 4 (TLR4, within kidney tissue and peripheral blood leukocytes (PBL in a porcine model of PN.Three adult pigs each underwent unilateral renal hilar cross clamping for 180 min followed by a 15 min reperfusion. The contralateral kidney served as control. Biopsies of clamped kidneys were obtained at baseline (time 0, every 60 min during the hypoxic phase, and post-reperfusion. Control kidneys were biopsied once at 180 min. Peripheral blood was sampled at time 0, every 30 min during the hypoxic phase, and post-reperfusion. HIF-1α and TLR4 expression in kidney tissue and PBL were analyzed by Western blotting. I/R-related histological changes were assessed.Expression of HIF-1α in clamped kidneys and PBL was below detection level at baseline, rising to detectable levels after 60 min of hypoxia, and continuing to rise throughout the hypoxic and reperfusion phases. Expression of TLR-4 in clamped kidneys followed a similar trend with initial detection after 30-60 min of hypoxia. Control kidneys exhibited no change in HIF-1α or TLR-4 expression. I/R-related histologic changes were minimal, primarily mild tubular dilatation.In a porcine model of PN, HIF-1α and TLR4 exhibited robust, I/R-related increases in expression in kidney tissue and PBL. Further studies investigating these molecules as potential markers of AKI are warranted.

  9. Role of adaptor proteins and clathrin in the trafficking of human kidney anion exchanger 1 (kAE1) to the cell surface.

    Science.gov (United States)

    Junking, Mutita; Sawasdee, Nunghathai; Duangtum, Natapol; Cheunsuchon, Boonyarit; Limjindaporn, Thawornchai; Yenchitsomanus, Pa-thai

    2014-07-01

    Kidney anion exchanger 1 (kAE1) plays an important role in acid-base homeostasis by mediating chloride/bicarbornate (Cl-/HCO3-) exchange at the basolateral membrane of α-intercalated cells in the distal nephron. Impaired intracellular trafficking of kAE1 caused by mutations of SLC4A1 encoding kAE1 results in kidney disease - distal renal tubular acidosis (dRTA). However, it is not known how the intracellular sorting and trafficking of kAE1 from trans-Golgi network (TGN) to the basolateral membrane occurs. Here, we studied the role of basolateral-related sorting proteins, including the mu1 subunit of adaptor protein (AP) complexes, clathrin and protein kinase D, on kAE1 trafficking in polarized and non-polarized kidney cells. By using RNA interference, co-immunoprecipitation, yellow fluorescent protein-based protein fragment complementation assays and immunofluorescence staining, we demonstrated that AP-1 mu1A, AP-3 mu1, AP-4 mu1 and clathrin (but not AP-1 mu1B, PKD1 or PKD2) play crucial roles in intracellular sorting and trafficking of kAE1. We also demonstrated colocalization of kAE1 and basolateral-related sorting proteins in human kidney tissues by double immunofluorescence staining. These findings indicate that AP-1 mu1A, AP-3 mu1, AP-4 mu1 and clathrin are required for kAE1 sorting and trafficking from TGN to the basolateral membrane of acid-secreting α-intercalated cells. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Integration of object-oriented knowledge representation with the CLIPS rule based system

    Science.gov (United States)

    Logie, David S.; Kamil, Hasan

    1990-01-01

    The paper describes a portion of the work aimed at developing an integrated, knowledge based environment for the development of engineering-oriented applications. An Object Representation Language (ORL) was implemented in C++ which is used to build and modify an object-oriented knowledge base. The ORL was designed in such a way so as to be easily integrated with other representation schemes that could effectively reason with the object base. Specifically, the integration of the ORL with the rule based system C Language Production Systems (CLIPS), developed at the NASA Johnson Space Center, will be discussed. The object-oriented knowledge representation provides a natural means of representing problem data as a collection of related objects. Objects are comprised of descriptive properties and interrelationships. The object-oriented model promotes efficient handling of the problem data by allowing knowledge to be encapsulated in objects. Data is inherited through an object network via the relationship links. Together, the two schemes complement each other in that the object-oriented approach efficiently handles problem data while the rule based knowledge is used to simulate the reasoning process. Alone, the object based knowledge is little more than an object-oriented data storage scheme; however, the CLIPS inference engine adds the mechanism to directly and automatically reason with that knowledge. In this hybrid scheme, the expert system dynamically queries for data and can modify the object base with complete access to all the functionality of the ORL from rules.

  11. Intermittent hypoxia increases kidney tumor vascularization in a murine model of sleep apnea.

    Science.gov (United States)

    Vilaseca, Antoni; Campillo, Noelia; Torres, Marta; Musquera, Mireia; Gozal, David; Montserrat, Josep M; Alcaraz, Antonio; Touijer, Karim A; Farré, Ramon; Almendros, Isaac

    2017-01-01

    We investigate the effects of intermittent hypoxia (IH), a characteristic feature of obstructive sleep apnea (OSA), on renal cancer progression in an animal and cell model. An in vivo mouse model (Balb/c, n = 50) of kidney cancer was used to assess the effect of IH on tumor growth, metastatic capacity, angiogenesis and tumor immune response. An in vitro model tested the effect of IH on RENCA cells, macrophages and endothelial cells. Tumor growth, metastatic capacity, circulating vascular endothelial growth factor (VEGF) and content of endothelial cells, tumor associated macrophages and their phenotype were assessed in the tumor. In vitro, VEGF cell expression was quantified.Although IH did not boost tumor growth, it significantly increased endothelial cells (p = 0.001) and circulating VEGF (p<0.001) in the in vivo model. Macrophages exposed to IH in vitro increased VEGF expression, whereas RENCA cells and endothelial cells did not. These findings are in keeping with previous clinical data suggesting that OSA has no effect on kidney cancer size and that the association observed between OSA and higher Fuhrman grade of renal cell carcinoma may be mediated though a proangiogenic process, with a key role of macrophages.

  12. Intermittent hypoxia increases kidney tumor vascularization in a murine model of sleep apnea.

    Directory of Open Access Journals (Sweden)

    Antoni Vilaseca

    Full Text Available We investigate the effects of intermittent hypoxia (IH, a characteristic feature of obstructive sleep apnea (OSA, on renal cancer progression in an animal and cell model. An in vivo mouse model (Balb/c, n = 50 of kidney cancer was used to assess the effect of IH on tumor growth, metastatic capacity, angiogenesis and tumor immune response. An in vitro model tested the effect of IH on RENCA cells, macrophages and endothelial cells. Tumor growth, metastatic capacity, circulating vascular endothelial growth factor (VEGF and content of endothelial cells, tumor associated macrophages and their phenotype were assessed in the tumor. In vitro, VEGF cell expression was quantified.Although IH did not boost tumor growth, it significantly increased endothelial cells (p = 0.001 and circulating VEGF (p<0.001 in the in vivo model. Macrophages exposed to IH in vitro increased VEGF expression, whereas RENCA cells and endothelial cells did not. These findings are in keeping with previous clinical data suggesting that OSA has no effect on kidney cancer size and that the association observed between OSA and higher Fuhrman grade of renal cell carcinoma may be mediated though a proangiogenic process, with a key role of macrophages.

  13. Cerebral activation associated with sexual arousal in response to a pornographic clip: A 15O-H2O PET study in heterosexual men.

    Science.gov (United States)

    Bocher, M; Chisin, R; Parag, Y; Freedman, N; Meir Weil, Y; Lester, H; Mishani, E; Bonne, O

    2001-07-01

    This study attempted to use PET and 15O-H2O to measure changes in regional cerebral blood flow (rCBF) during sexual arousal evoked in 10 young heterosexual males while they watched a pornographic video clip, featuring heterosexual intercourse. This condition was compared with other mental setups evoked by noisy, nature, and talkshow audiovisual clips. Immediately after each clip, the participants answered three questions pertaining to what extent they thought about sex, felt aroused, and sensed an erection. They scored their answers using a 1 to 10 scale. SPM was used for data analysis. Sexual arousal was mainly associated with activation of bilateral, predominantly right, inferoposterior extrastriate cortices, of the right inferolateral prefrontal cortex and of the midbrain. The significance of those findings is discussed in the light of current theories concerning selective attention, "mind reading" and mirroring, reinforcement of pleasurable stimuli, and penile erection.

  14. Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, Francois; Fournier, Catherine; Leon, Carine; Legendre, Christophe [Paris Descartes University, AP-HP, Hopital Necker-Enfants Malades, Renal Transplantation Department, Paris (France); Pavlov, Patrik [Linkoeping University, Linkoeping (Sweden); Tissier, Anne-Marie; Correas, Jean-Michel [Paris Descartes University, AP-HP, Hopital Necker-Enfants Malades, Radiology Department, Paris (France); Harache, Benoit; Hignette, Chantal; Weinmann, Pierre [Paris Descartes University, AP-HP, Hopital Europeen Georges Pompidou, Nuclear Medicine Department, Paris (France); Eladari, Dominique [Paris Descartes University, and INSERM, Unit 970, AP-HP, Hopital Europeen Georges Pompidou, Physiology Department, Paris (France); Timsit, Marc-Olivier; Mejean, Arnaud [Paris Descartes University, AP-HP, Hopital Europeen Georges Pompidou, Urology Department, Paris (France); Friedlander, Gerard; Courbebaisse, Marie [Paris Descartes University, and INSERM, Unit 1151, AP-HP, Hopital Europeen Georges Pompidou, Physiology Department, Paris (France); Houillier, Pascal [Paris Descartes University, INSERM, Unit umrs1138, and CNRS Unit erl8228, AP-HP, Hopital Europeen Georges Pompidou, Physiology Department, Paris (France)

    2017-02-15

    Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m{sup 2}/kidney. This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula: Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up. A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m{sup 2}/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m{sup 2}/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up. Length-split GFR can be used to detect patients requiring scintigraphy. (orig.)

  15. Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors

    International Nuclear Information System (INIS)

    Gaillard, Francois; Fournier, Catherine; Leon, Carine; Legendre, Christophe; Pavlov, Patrik; Tissier, Anne-Marie; Correas, Jean-Michel; Harache, Benoit; Hignette, Chantal; Weinmann, Pierre; Eladari, Dominique; Timsit, Marc-Olivier; Mejean, Arnaud; Friedlander, Gerard; Courbebaisse, Marie; Houillier, Pascal

    2017-01-01

    Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m"2/kidney. This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula: Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up. A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m"2/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m"2/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up. Length-split GFR can be used to detect patients requiring scintigraphy. (orig.)

  16. Chronic kidney disease: an inherent risk factor for acute kidney injury?

    Science.gov (United States)

    Singh, Prabhleen; Rifkin, Dena E; Blantz, Roland C

    2010-09-01

    Epidemiologic evidence suggests that chronic kidney disease (CKD) is a risk factor for acute kidney injury (AKI) due to the prevalence of CKD in patients who have episodes of AKI. However, the high burden of comorbidities such as age, diabetes, peripheral vascular, cardiovascular, and liver disease accompanying CKD, and the difficulties of defining AKI in the setting of CKD make these observations difficult to interpret. These comorbidities not only could alter the course of AKI but also may be the driving force behind the epidemiologic association between CKD and AKI because of systemic changes and/or increased exposure to potential nephrotoxic risks. Here, we contend that studies suggesting that CKD is a risk factor for AKI may suffer from residual confounding and reflect an overall susceptibility to illness rather than biologic susceptibility of the kidney parenchyma to injury. In support of our argument, we discuss the clinical evidence from epidemiologic studies, and the knowledge obtained from animal models on the pathophysiology of AKI and CKD, demonstrating a preconditioning influence of the previously impaired kidneys against subsequent injury. We conclude that, under careful analysis, factors apart from the inherent pathophysiology of the diseased kidney may be responsible for the increased frequency of AKI in CKD patients, and the impact of CKD on the risk and severity of AKI needs further investigation. Moreover, certain elements in the pathophysiology of a previously injured kidney may, surprisingly, bear out to be protective against AKI.

  17. Real-time video streaming of sonographic clips using domestic internet networks and free videoconferencing software.

    Science.gov (United States)

    Liteplo, Andrew S; Noble, Vicki E; Attwood, Ben H C

    2011-11-01

    As the use of point-of-care sonography spreads, so too does the need for remote expert over-reading via telesonogrpahy. We sought to assess the feasibility of using familiar, widespread, and cost-effective existent technology to allow remote over-reading of sonograms in real time and to compare 4 different methods of transmission and communication for both the feasibility of transmission and image quality. Sonographic video clips were transmitted using 2 different connections (WiFi and 3G) and via 2 different videoconferencing modalities (iChat [Apple Inc, Cupertino, CA] and Skype [Skype Software Sàrl, Luxembourg]), for a total of 4 different permutations. The clips were received at a remote location and recorded and then scored by expert reviewers for image quality, resolution, and detail. Wireless transmission of sonographic clips was feasible in all cases when WiFi was used and when Skype was used over a 3G connection. Images transmitted via a WiFi connection were statistically superior to those transmitted via 3G in all parameters of quality (average P = .031), and those sent by iChat were superior to those sent by Skype but not statistically so (average P = .057). Wireless transmission of sonographic video clips using inexpensive hardware, free videoconferencing software, and domestic Internet networks is feasible with retention of image quality sufficient for interpretation. WiFi transmission results in greater image quality than transmission by a 3G network.

  18. Relationships between serum MCP-1 and subclinical kidney disease: African American-Diabetes Heart Study

    Directory of Open Access Journals (Sweden)

    Murea Mariana

    2012-11-01

    Full Text Available Abstract Background Monocyte chemoattractant protein-1 (MCP-1 plays important roles in kidney disease susceptibility and atherogenesis in experimental models. Relationships between serum MCP-1 concentration and early nephropathy and subclinical cardiovascular disease (CVD were assessed in African Americans (AAs with type 2 diabetes (T2D. Methods Serum MCP-1 concentration, urine albumin:creatinine ratio (ACR, estimated glomerular filtration rate (eGFR, and atherosclerotic calcified plaque (CP in the coronary and carotid arteries and infrarenal aorta were measured in 479 unrelated AAs with T2D. Generalized linear models were fitted to test for associations between MCP-1 and urine ACR, eGFR, and CP. Results Participants were 57% female, with mean ± SD (median age 55.6±9.5 (55.0 years, diabetes duration 10.3±8.2 (8.0 years, urine ACR 149.7±566.7 (14.0 mg/g, CKD-EPI eGFR 92.4±23.3 (92.0 ml/min/1.73m2, MCP-1 262.9±239.1 (224.4 pg/ml, coronary artery CP 280.1±633.8 (13.5, carotid artery CP 47.1±132.9 (0, and aorta CP 1616.0±2864.0 (319.0. Adjusting for age, sex, smoking, HbA1c, BMI, and LDL, serum MCP-1 was positively associated with albuminuria (parameter estimate 0.0021, P=0.04 and negatively associated with eGFR (parameter estimate −0.0003, P=0.001. MCP-1 remained associated with eGFR after adjustment for urine ACR. MCP-1 levels did not correlate with the extent of CP in any vascular bed, HbA1c or diabetes duration, but were positively associated with BMI. No interaction between BMI and MCP-1 was detected on nephropathy outcomes. Conclusions Serum MCP-1 levels are associated with eGFR and albuminuria in AAs with T2D. MCP-1 was not associated with subclinical CVD in this population. Inflammation appears to play important roles in development and/or progression of kidney disease in AAs.

  19. Comparison of Outcome After Percutaneous Mitral Valve Repair With the MitraClip in Patients With Versus Without Atrial Fibrillation

    NARCIS (Netherlands)

    Velu, Juliëtte F.; Kortlandt, Friso A.; Hendriks, Tom; Schurer, Remco A. J.; van Boven, Ad J.; Koch, Karel T.; Vis, M. Marije; Henriques, Jose P.; Piek, Jan J.; van den Branden, Ben J. L.; Schaap, Jeroen; Rensing, Benno J.; Swaans, Martin J.; Bouma, Berto J.; van der Heyden, Jan A. S.; Baan, Jan

    2017-01-01

    Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is

  20. Magnetic resonance imaging of the transplanted kidneys

    International Nuclear Information System (INIS)

    Matsui, Suguru; Lee, Chol-Joo; Hamashima, Takashi

    1987-01-01

    Magnetic resonance imaging (MRI) is a new noninvasive means for evaluating pathological changes of kidney transplants. Thirty kidney transplants were examined by MRI study, comparing with 12 donor kidneys as control. Imaging of well functioning grafts using inversion recovery (IR) method displayed a clear figure of corticomedullary differentiation (CMD). Kidneys under acute rejection, chronic rejection, and ciclosporin nephrotoxicity displayed poor CMD. CMD of Kidneys under ATN was poor on IR imaging, but clear on T 1 weightened imaging. T 1 values of kidney grafts were obtained as the mean value of T 1 relaxation time of three areas including upper pole, lower pole, and the middle of the cortex. T 1 value of the grafts under chronic rejection was similar to that of well functioning grafts. The value increased in case of acute rejection, ATN, and ciclosporin nephrotoxicity and decreased as the graft function was getting better. Imaging and the estimation of T 1 value of kidney transplants of MRI were effective for evaluating graft function but of no use for differentiation of causes of graft deterioration. (author)

  1. Experimental evaluation of fluorescent (alizarin red S and calcein) and clip-tag markers for stock assessment of ark shell, Anadara broughtonii

    Science.gov (United States)

    Zhou, Shanshan; Zhang, Xiumei; Li, Wentao; Li, Long; Cai, Xingyuan

    2017-03-01

    Release programs to enhance stocks of ark shell ( Anadara broughtonii) have been undertaken in a number of Asian countries, but their effectiveness has rarely been investigated owing to a lack of marking methods. The quality and longevity of fluorescent markers, alizarin red S (ARS) and calcein (CAL) (200 and 300 mg/L), as well as clip tags, were tested on juvenile A. broughtonii. No significant differences in survival or shell growth were observed in juveniles stained with either of the two fluorochromes after a 160-day culture period, but the retention rate was 100% after 1 year. Fluorescent marks (≥grade 3) were observable microscopically in juveniles stained with the two fluorochromes, and some fluorescent marks (≥grade 4) were visible with the naked eye after 1 year. ARS-marked shells were brighter than those marked with CAL, and shells marked with 300 mg/L of the fluorochromes were easier to detect than those marked with 200 mg/L. Clip tags were incorporated into the shell as the bivalve grew, and the retention rate was 64.25% after 160 days. Significant differences in survival (at 30 days), shell length (at 60, 90, 120, and 160 days), and wet weight (at 90, 120, and 160 days) were observed between the clip-tagged and control groups (all P< 0.05), indicating that the tags may have passive effects on the ark shell. The results suggest that both ARS and CAL are suitable to mark A. broughtonii for large-scale restocking programs, and that optimal marking quality was achieved with 300 mg/L ARS. Lighter and smaller clip tags need to be developed to reduce injury and increase survival rate of clams.

  2. Simple Kidney Cysts

    Science.gov (United States)

    ... Solitary Kidney Your Kidneys & How They Work Simple Kidney Cysts What are simple kidney cysts? Simple kidney cysts are abnormal, fluid-filled ... that form in the kidneys. What are the kidneys and what do they do? The kidneys are ...

  3. Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys

    Directory of Open Access Journals (Sweden)

    Beomseok Sohn

    2014-04-01

    Conclusion: Obtaining ARFI measurements of the kidney is feasible in young children with median SWVs of 1.75 m/sec in normal kidneys. Median SWVs increased in high-grade hydronephrotic kidneys but were not different between hydronephrotic kidneys with and without UPJO.

  4. Integrated Kidney Exosome Analysis for the Detection of Kidney Transplant Rejection.

    Science.gov (United States)

    Park, Jongmin; Lin, Hsing-Ying; Assaker, Jean Pierre; Jeong, Sangmoo; Huang, Chen-Han; Kurdi, A; Lee, Kyungheon; Fraser, Kyle; Min, Changwook; Eskandari, Siawosh; Routray, Sujit; Tannous, Bakhos; Abdi, Reza; Riella, Leonardo; Chandraker, Anil; Castro, Cesar M; Weissleder, Ralph; Lee, Hakho; Azzi, Jamil R

    2017-11-28

    Kidney transplant patients require life-long surveillance to detect allograft rejection. Repeated biopsy, albeit the clinical gold standard, is an invasive procedure with the risk of complications and comparatively high cost. Conversely, serum creatinine or urinary proteins are noninvasive alternatives but are late markers with low specificity. We report a urine-based platform to detect kidney transplant rejection. Termed iKEA (integrated kidney exosome analysis), the approach detects extracellular vesicles (EVs) released by immune cells into urine; we reasoned that T cells, attacking kidney allografts, would shed EVs, which in turn can be used as a surrogate marker for inflammation. We optimized iKEA to detect T-cell-derived EVs and implemented a portable sensing system. When applied to clinical urine samples, iKEA revealed high level of CD3-positive EVs in kidney rejection patients and achieved high detection accuracy (91.1%). Fast, noninvasive, and cost-effective, iKEA could offer new opportunities in managing transplant recipients, perhaps even in a home setting.

  5. R1 autonomic nervous system in acute kidney injury.

    Science.gov (United States)

    Hering, Dagmara; Winklewski, Pawel J

    2017-02-01

    Acute kidney injury (AKI) is a rapid loss of kidney function resulting in accumulation of end metabolic products and associated abnormalities in fluid, electrolyte and acid-base homeostasis. The pathophysiology of AKI is complex and multifactorial involving numerous vascular, tubular and inflammatory pathways. Neurohumoral activation with heightened activity of the sympathetic nervous system and renin-angiotensin-aldosterone system play a critical role in this scenario. Inflammation and/or local renal ischaemia are underlying mechanisms triggering renal tissue hypoxia and resultant renal microcirculation dysfunction; a common feature of AKI occurring in numerous clinical conditions leading to a high morbidity and mortality rate. The contribution of renal nerves to the pathogenesis of AKI has been extensively demonstrated in a series of experimental models over the past decades. While this has led to better knowledge of the pathogenesis of human AKI, therapeutic approaches to improve patient outcomes are scarce. Restoration of autonomic regulatory function with vagal nerve stimulation resulting in anti-inflammatory effects and modulation of centrally-mediated mechanisms could be of clinical relevance. Evidence from experimental studies suggests that a therapeutic splenic ultrasound approach may prevent AKI via activation of the cholinergic anti-inflammatory pathway. This review briefly summarizes renal nerve anatomy, basic insights into neural control of renal function in the physiological state and the involvement of the autonomic nervous system in the pathophysiology of AKI chiefly due to sepsis, cardiopulmonary bypass and ischaemia/reperfusion experimental model. Finally, potentially preventive experimental pre-clinical approaches for the treatment of AKI aimed at sympathetic inhibition and/or parasympathetic stimulation are presented. © 2016 John Wiley & Sons Australia, Ltd.

  6. Human Anti-Oxidation Protein A1M—A Potential Kidney Protection Agent in Peptide Receptor Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    Jonas Ahlstedt

    2015-12-01

    Full Text Available Peptide receptor radionuclide therapy (PRRT has been in clinical use for 15 years to treat metastatic neuroendocrine tumors. PRRT is limited by reabsorption and retention of the administered radiolabeled somatostatin analogues in the proximal tubule. Consequently, it is essential to develop and employ methods to protect the kidneys during PRRT. Today, infusion of positively charged amino acids is the standard method of kidney protection. Other methods, such as administration of amifostine, are still under evaluation and show promising results. α1-microglobulin (A1M is a reductase and radical scavenging protein ubiquitously present in plasma and extravascular tissue. Human A1M has antioxidation properties and has been shown to prevent radiation-induced in vitro cell damage and protect non-irradiated surrounding cells. It has recently been shown in mice that exogenously infused A1M and the somatostatin analogue octreotide are co-localized in proximal tubules of the kidney after intravenous infusion. In this review we describe the current situation of kidney protection during PRRT, discuss the necessity and implications of more precise dosimetry and present A1M as a new, potential candidate for renal protection during PRRT and related targeted radionuclide therapies.

  7. Endoscopic Management of Gastrointestinal Leaks and Bleeding with the Over-the-Scope Clip: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Mahesh Kumar Goenka

    2017-01-01

    Full Text Available Background/Aims The over-the-scope clip (OTSC is a device used for endoscopic closure of perforations, leaks and fistulas, and for endoscopic hemostasis. To evaluate the clinical effectiveness and safety of OTSC. Methods Between October 2013 and November 2015, 12 patients underwent OTSC placement by an experienced endoscopist. OTSC was used for the closure of gastrointestinal (GI leaks and fistula in six patients, three of which were iatrogenic (esophageal, gastric, and duodenal and three of which were inflammatory. In six patients, OTSC was used for hemostasis of non-variceal upper GI bleeding. Endoscopic tattooing using India ink was used to assist the accurate placement of the clip. Results All subjects except one with a colonic defect experienced immediate technical success as well as long-term clinical success, during a mean follow-up of 6 weeks. Only one clip was required to close each of the GI defects and to achieve hemostasis in all patients. There were no misfirings or complications of clips. The procedure was well tolerated, and patients were hospitalized for an average of 8 days (range, 3 to 10. Antiplatelet therapy was continued in patients with GI bleeding. Conclusions In our experience, OTSC was safe and effective for the closure of GI defect and to achieve hemostasis of non-variceal GI bleeding.

  8. Thermoablation of Malignant Kidney Tumors Using Magnetic Nanoparticles: An In Vivo Feasibility Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Bruners, Philipp; Braunschweig, Till; Hodenius, Michael; Pietsch, Hubertus; Penzkofer, Tobias; Baumann, Martin; Guenther, Rolf W.; Schmitz-Rode, Thomas; Mahnken, Andreas H.

    2010-01-01

    The objective of this study was to assess the technical feasibility of CT-guided magnetic thermoablation for the treatment of malignant kidney tumors in a VX2 tumor rabbit model. VX2 tumors were implanted into the kidneys of five rabbits and allowed to grow for 2 weeks. After preinterventional CT perfusion imaging, CT-guided injection of superparamagnetic iron oxide particles (300 μl) was performed, followed by exposure of the animals to an alternating electromagnetic field for 15 min (∼0.32 kA/m). Then animals underwent CT perfusion imaging again. Afterward, animals were sacrificed and kidneys were dissected for macroscopic and histological evaluation. Changes in perfusion before and after exposure to the alternating magnetic field were analyzed. In one animal no tumor growth could be detected so the animal was used for optimization of the ablation procedure including injection technique and peri-interventional cross-sectional imaging (CT, MRI). After image-guided intratumoral injection of ferrofluids, the depiction of nanoparticle distribution by CT correlated well with macroscopic evaluation of the dissected kidneys. MRI was limited due to severe susceptibility artefacts. Postinterventional CT perfusion imaging revealed a perfusion deficiency around the ferrofluid deposits. Histological workup showed different zones of thermal damage adjacent to the ferrofluid deposits. In conclusion, CT-guided magnetic thermoablation of malignant kidney tumors is technically feasible in an animal model and results in a perfusion deficiency indicating tumor necrosis as depicted by CT perfusion imaging and shown in histological evaluation.

  9. Experimental transonic flutter characteristics of two 72 deg-sweep delta-wing models

    Science.gov (United States)

    Doggett, Robert V., Jr.; Soistmann, David L.; Spain, Charles V.; Parker, Ellen C.; Silva, Walter A.

    1989-01-01

    Transonic flutter boundaries are presented for two simple, 72 deg. sweep, low-aspect-ratio wing models. One model was an aspect-ratio 0.65 delta wing; the other model was an aspect-ratio 0.54 clipped-delta wing. Flutter boundaries for the delta wing are presented for the Mach number range of 0.56 to 1.22. Flutter boundaries for the clipped-delta wing are presented for the Mach number range of 0.72 to 0.95. Selected vibration characteristics of the models are also presented.

  10. Effects of low dose radiation on expressions of ICAM-1 mRNA and protein in kidney of diabetic mice

    International Nuclear Information System (INIS)

    Zhang Chi; Li Xiaokun; Gong Shouliang; Liu Xiaoju; Zhao Xue; Liu Xiaoju; Zhao Xue; Shen Wenjie; Li Cai; Cai Lu

    2010-01-01

    Objective: To study the effects of low dose radiation (LDR) on the expressions of intercellular adhesion molecule-1 (ICAM-1) mRNA and protein in kidney of diabetes mellitus (DM) mice and illuminate that anti-inflammation of LDR is a main mechanism for diabetic therapy. Methods: The healthy and right age C57BL/6J mice were divided into 4 groups including control, DM, LDR and DM/LDR. The mice in DM and DM/LDR groups were injected intraperitoneally with streptozocin (STZ) to set up DM models. The mice in DM/LDR and LDR groups were irradiated with 25 mGy every other day for 4 weeks. The expressions of ICAM-1 mRNA and protein in kidney were detected with RT-PCR and Western blotting 2, 4, 8, 12 and 16 weeks after irradiation. Results: The expressions of ICAM-1 mRNA and protein in kidney had no significant difference among 4 groups before LDR (P>0.05). The expressions of ICAM-1 mRNA and protein 2 weeks after irradiation with LDR were higher than those in the other 3 groups (P<0.05). The expressions of ICAM-1 mRNA and protein in the DM/LDR group 4 weeks after irradiation were also significantly higher than those in non-DM groups (P<0.05), but still significantly lower than those in DM group (P<0.05), and the significant differences were kept to 16 weeks after irradiation. But the expressions of ICAM-1 mRNA and protein in LDR group were significantly higher than those in control group (P<0.05). IHC assay showed that the glomerular and tubular in DM and DM/LDR groups were abnormal and the quantities of the positive staining cells were significantly increased compared with non-DM groups. However the damage of glomerular and tubular in DM/LDR was significantly supressed compared with DM group and the positive staining cells were also decreased. Conclusion: Under the circumstance of DM, LDR can significantly decrease the expressions of ICAM-1 mRNA and protein in mouse kidney to relief the inflammation reaction in kidney; but in normal condition, LDR can improve the immunity and

  11. Antifibrotic Effects of the Dual CCR2/CCR5 Antagonist Cenicriviroc in Animal Models of Liver and Kidney Fibrosis.

    Directory of Open Access Journals (Sweden)

    Eric Lefebvre

    Full Text Available Interactions between C-C chemokine receptor types 2 (CCR2 and 5 (CCR5 and their ligands, including CCL2 and CCL5, mediate fibrogenesis by promoting monocyte/macrophage recruitment and tissue infiltration, as well as hepatic stellate cell activation. Cenicriviroc (CVC is an oral, dual CCR2/CCR5 antagonist with nanomolar potency against both receptors. CVC's anti-inflammatory and antifibrotic effects were evaluated in a range of preclinical models of inflammation and fibrosis.Monocyte/macrophage recruitment was assessed in vivo in a mouse model of thioglycollate-induced peritonitis. CCL2-induced chemotaxis was evaluated ex vivo on mouse monocytes. CVC's antifibrotic effects were evaluated in a thioacetamide-induced rat model of liver fibrosis and mouse models of diet-induced non-alcoholic steatohepatitis (NASH and renal fibrosis. Study assessments included body and liver/kidney weight, liver function test, liver/kidney morphology and collagen deposition, fibrogenic gene and protein expression, and pharmacokinetic analyses.CVC significantly reduced monocyte/macrophage recruitment in vivo at doses ≥20 mg/kg/day (p < 0.05. At these doses, CVC showed antifibrotic effects, with significant reductions in collagen deposition (p < 0.05, and collagen type 1 protein and mRNA expression across the three animal models of fibrosis. In the NASH model, CVC significantly reduced the non-alcoholic fatty liver disease activity score (p < 0.05 vs. controls. CVC treatment had no notable effect on body or liver/kidney weight.CVC displayed potent anti-inflammatory and antifibrotic activity in a range of animal fibrosis models, supporting human testing for fibrotic diseases. Further experimental studies are needed to clarify the underlying mechanisms of CVC's antifibrotic effects. A Phase 2b study in adults with NASH and liver fibrosis is fully enrolled (CENTAUR Study 652-2-203; NCT02217475.

  12. Acute Kidney Injury as a Risk Factor for Delirium and Coma during Critical Illness.

    Science.gov (United States)

    Siew, Edward D; Fissell, William H; Tripp, Christina M; Blume, Jeffrey D; Wilson, Matthew D; Clark, Amanda J; Vincz, Andrew J; Ely, E Wesley; Pandharipande, Pratik P; Girard, Timothy D

    2017-06-15

    Acute kidney injury may contribute to distant organ dysfunction. Few studies have examined kidney injury as a risk factor for delirium and coma. To examine whether acute kidney injury is associated with delirium and coma in critically ill adults. In a prospective cohort study of intensive care unit patients with respiratory failure and/or shock, we examined the association between acute kidney injury and daily mental status using multinomial transition models adjusting for demographics, nonrenal organ failure, sepsis, prior mental status, and sedative exposure. Acute kidney injury was characterized daily using the difference between baseline and peak serum creatinine and staged according to Kidney Disease Improving Global Outcomes criteria. Mental status (normal vs. delirium vs. coma) was assessed daily with the Confusion Assessment Method for the ICU and Richmond Agitation-Sedation Scale. Among 466 patients, stage 2 acute kidney injury was a risk factor for delirium (odds ratio [OR], 1.55; 95% confidence interval [CI], 1.07-2.26) and coma (OR, 2.04; 95% CI, 1.25-3.34) as was stage 3 injury (OR for delirium, 2.56; 95% CI, 1.57-4.16) (OR for coma, 3.34; 95% CI, 1.85-6.03). Daily peak serum creatinine (adjusted for baseline) values were also associated with delirium (OR, 1.35; 95% CI, 1.18-1.55) and coma (OR, 1.44; 95% CI, 1.20-1.74). Renal replacement therapy modified the association between stage 3 acute kidney injury and daily peak serum creatinine and both delirium and coma. Acute kidney injury is a risk factor for delirium and coma during critical illness.

  13. The Inflammatory Transcription Factors NFκB, STAT1 and STAT3 Drive Age-Associated Transcriptional Changes in the Human Kidney

    Science.gov (United States)

    O’Brown, Zach K.; Van Nostrand, Eric L.; Higgins, John P.; Kim, Stuart K.

    2015-01-01

    Human kidney function declines with age, accompanied by stereotyped changes in gene expression and histopathology, but the mechanisms underlying these changes are largely unknown. To identify potential regulators of kidney aging, we compared age-associated transcriptional changes in the human kidney with genome-wide maps of transcription factor occupancy from ChIP-seq datasets in human cells. The strongest candidates were the inflammation-associated transcription factors NFκB, STAT1 and STAT3, the activities of which increase with age in epithelial compartments of the renal cortex. Stimulation of renal tubular epithelial cells with the inflammatory cytokines IL-6 (a STAT3 activator), IFNγ (a STAT1 activator), or TNFα (an NFκB activator) recapitulated age-associated gene expression changes. We show that common DNA variants in RELA and NFKB1, the two genes encoding subunits of the NFκB transcription factor, associate with kidney function and chronic kidney disease in gene association studies, providing the first evidence that genetic variation in NFκB contributes to renal aging phenotypes. Our results suggest that NFκB, STAT1 and STAT3 underlie transcriptional changes and chronic inflammation in the aging human kidney. PMID:26678048

  14. Kidney removal - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100069.htm Kidney removal (nephrectomy) - series—Normal anatomy To use the sharing features on this page, please enable JavaScript. Go to slide 1 out of 5 Go to slide 2 out of ... to slide 5 out of 5 Overview The kidneys are paired organs that lie posterior to the ...

  15. Preoperative Prediction of the Necessity for Anterior Clinoidectomy During Microsurgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Burkhardt, Jan-Karl; Tabani, Halima; Safaee, Michael M; Lawton, Michael T

    2018-01-01

    Although most posterior communicating artery (PCoA) aneurysms can be clipped easily with excellent results, some require anterior clinoidectomy for safe and complete clipping. To review our microsurgical series of ruptured PCoA aneurysms and identify the preoperative predictors for anterior clinoidectomy during microsurgical clipping for PCoA aneurysms. Results from microsurgical clipping of 104 patients with ruptured PCoA aneurysms were reviewed retrospectively. Distances and angles were obtained from computed tomographic angiography and compared between the anterior and nonanterior clinoidectomy groups. Anterior clinoidectomy was required in 19 of the 104 cases (18%). None developed surgical complications due to anterior clinoid process (ACP) resection, including postoperative visual deficit. Univariate and multivariate analyses revealed that the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were statistically significant predictive factors for the need of anterior clinoidectomy. Based on a receiver operating characteristic analysis, the distances from the ACP tip to the aneurysmal proximal neck PCoA aneurysm surgery, the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were both found to be useful predictors of whether anterior clinoidectomy was required. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A comparison of CLIPS- and LISP-based approaches to the development of a real-time expert system

    Science.gov (United States)

    Frainier, R.; Groleau, N.; Bhatnagar, R.; Lam, C.; Compton, M.; Colombano, S.; Lai, S.; Szolovits, P.; Manahan, M.; Statler, I.

    1990-01-01

    This paper describes an ongoing expert system development effort started in 1988 which is evaluating both CLIPS- and LISP- based approaches. The expert system is being developed to a project schedule and is planned for flight on Space Shuttle Mission SLS-2 in 1992. The expert system will help astronauts do the best possible science for a vestibular physiology experiment already scheduled for that mission. The system gathers and reduces data from the experiment, flags 'interesting' results, and proposes changes in the experiment both to exploit the in-flight observations and to stay within the time allowed by Mission Control for the experiment. These tasks must all be performed in real time. Two Apple Macintosh computers are used. The CLIPS- and LISP- based environments are layered above the Macintosh computer Operating System. The 'CLIPS-based' environment includes CLIPS and HyperCard. The LlSP-based environment includes Common LISP, Parmenides (a frame system), and FRuleKit (a rule system). Important evaluation factors include ease of programming, performance against real-time requirements, usability by an astronaut, robustness, and ease of maintenance. Current results on the factors of ease of programming, performance against real-time requirements, and ease of maintenance are discussed.

  17. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2014-01-01

    to conventional orthogonal frequency division multiplexing (OFDM technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER.

  18. Mammalian target of rapamycin inhibition in polycystic kidney disease: From bench to bedside

    Directory of Open Access Journals (Sweden)

    Hyun-Jung Kim

    2012-09-01

    Full Text Available Autosomal dominant polycystic kidney disease (ADPKD is the most common life-threatening hereditary disease in the USA resulting in chronic kidney disease and the need for dialysis and transplantation. Approximately 85% of cases of ADPKD are caused by a mutation in the Pkd1 gene that encodes polycystin-1, a large membrane receptor. The Pkd1 gene mutation results in abnormal proliferation in tubular epithelial cells, which plays a crucial role in cyst development and/or growth in PKD. Activation of the proliferative mammalian target of rapamycin (mTOR signaling pathway has been demonstrated in polycystic kidneys from rodents and humans. mTOR inhibition with sirolimus or everolimus decreases cysts in most animal models of PKD including Pkd1 and Pkd2 gene deficient orthologous models of human disease. On the basis of animal studies, human studies were undertaken. Two large randomized clinical trials published in the New England Journal of Medicine of everolimus or sirolimus in ADPKD patients were very unimpressive and associated with a high side-effect profile. Possible reasons for the unimpressive nature of the human studies include their short duration, the high drop-out rate, suboptimal dosing, lack of randomization of “fast” and “slow progressors” and the lack of correlation between kidney size and kidney function in ADPKD. The future of mTOR inhibition in ADPKD is discussed.

  19. Kidney Problems

    Science.gov (United States)

    ... our e-newsletter! Aging & Health A to Z Kidney Problems Basic Facts & Information The kidneys are two ... kidney (renal) diseases are called nephrologists . What are Kidney Diseases? For about one-third of older people, ...

  20. Renal oxygenation and hemodynamics in acute kidney injury and chronic kidney disease

    Science.gov (United States)

    Singh, Prabhleen; Ricksten, Sven-Erik; Bragadottir, Gudrun; Redfors, Bengt; Nordquist, Lina

    2013-01-01

    Summary 1. Acute kidney injury (AKI) puts a major burden on health systems that may arise from multiple initiating insults, including ischemia-reperfusion injury, cardiovascular surgery, radio-contrast administration as well as sepsis. Similarly, the incidence and prevalence of chronic kidney disease (CKD) continues to increase with significant morbidity and mortality. Moreover, an increasing number of AKI patients survive to develop CKD and end-stage kidney disease (ESRD). 2. Although the mechanisms for development of AKI and progression of CKD remain poorly understood, initial impairment of oxygen balance is likely to constitute a common pathway, causing renal tissue hypoxia and ATP starvation that will in turn induce extracellular matrix production, collagen deposition and fibrosis. Thus, possible future strategies for one or both conditions may involve dopamine, loop-diuretics, inducible nitric oxide synthase inhibitors and atrial natriuretic peptide, substances that target kidney oxygen consumption and regulators of renal oxygenation such as nitric oxide and heme oxygenase-1. PMID:23360244