WorldWideScience

Sample records for kev x-ray transmissivity

  1. Transmission X-ray mirror

    International Nuclear Information System (INIS)

    Lairson, B.M.; Bilderback, D.H.

    1982-01-01

    Transmission X-ray mirrors have been made from 400 A to 10 000 A thick soap films and have been shown to have novel properties. Using grazing angles of incidence, low energy X-rays were reflected from the front surface while more energetic X-rays were transmitted through the mirror largely unattenuated. A wide bandpass monochromator was made from a silicon carbide mirror followed by a soap film transmission mirror and operated in the white beam at the cornell High Energy Synchrotron Source (CHESS). Bandpasses of ΔE/E=12% to 18% were achieved at 13 keV with peak efficiencies estimated to be between 55% and 75%, respectively. Several wide angle scattering photographs of stretched polyethylene and a phospholipid were obtained in 10 s using an 18% bandpass. (orig.)

  2. A laboratory 8 keV transmission full-field x-ray microscope with a polycapillary as condenser for bright and dark field imaging

    Energy Technology Data Exchange (ETDEWEB)

    Baumbach, S., E-mail: baumbach@rheinahrcampus.de; Wilhein, T. [Institute for X-Optics, University of Applied Sciences Koblenz, RheinAhrCampus Remagen, Joseph-Rovan-Allee 2, D-53424 Remagen (Germany); Kanngießer, B.; Malzer, W. [Institute for Optics and Atomic Physics, Technical University of Berlin, Hardenbergstrasse 36, D-10623 Berlin (Germany); Stiel, H. [Max-Born-Institute, Max-Born-Strasse 2A, D-12489 Berlin (Germany)

    2015-08-15

    This article introduces a laboratory setup of a transmission full-field x-ray microscope at 8 keV photon energy. The microscope operates in bright and dark field imaging mode with a maximum field of view of 50 μm. Since the illumination geometry determines whether the sample is illuminated homogeneously and moreover, if different imaging methods can be applied, the condenser optic is one of the most significant parts. With a new type of x-ray condenser, a polycapillary optic, we realized bright field imaging and for the first time dark field imaging at 8 keV photon energy in a laboratory setup. A detector limited spatial resolution of 210 nm is measured on x-ray images of Siemens star test patterns.

  3. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  4. 3D nanoscale imaging of the yeast, Schizosaccharomyces pombe, by full-field transmission x-ray microscopy at 5.4 keV

    Science.gov (United States)

    Chen, Jie; Yang, Yunhao; Zhang, Xiaobo; Andrews, Joy C.; Pianetta, Piero; Guan, Yong; Liu, Gang; Xiong, Ying; Wu, Ziyu; Tian, Yangchao

    2010-01-01

    Three-dimensional (3D) nanoscale structures of the fission yeast, Schizosaccharomyces pombe, can be obtained by full-field transmission hard x-ray microscopy with 30 nm resolution using synchrotron radiation sources. Sample preparation is relatively simple and the samples are portable across various imaging environments, allowing for high throughput sample screening. The yeast cells were fixed and double stained with Reynold’s lead citrate and uranyl acetate. We performed both absorption contrast and Zernike phase contrast imaging on these cells in order to test this method. The membranes, nucleus and subcellular organelles of the cells were clearly visualized using absorption contrast mode. The x-ray images of the cells could be used to study the spatial distributions of the organelles in the cells. These results show unique structural information, demonstrating that hard x-ray microscopy is a complementary method for imaging and analyzing biological samples. PMID:20349228

  5. 3D nanoscale imaging of the yeast, Schizosaccharomyces pombe, by full-field transmission X-ray microscopy at 5.4 keV.

    Science.gov (United States)

    Chen, Jie; Yang, Yunhao; Zhang, Xiaobo; Andrews, Joy C; Pianetta, Piero; Guan, Yong; Liu, Gang; Xiong, Ying; Wu, Ziyu; Tian, Yangchao

    2010-07-01

    Three-dimensional (3D) nanoscale structures of the fission yeast, Schizosaccharomyces pombe, can be obtained by full-field transmission hard X-ray microscopy with 30 nm resolution using synchrotron radiation sources. Sample preparation is relatively simple and the samples are portable across various imaging environments, allowing for high-throughput sample screening. The yeast cells were fixed and double-stained with Reynold's lead citrate and uranyl acetate. We performed both absorption contrast and Zernike phase contrast imaging on these cells in order to test this method. The membranes, nucleus, and subcellular organelles of the cells were clearly visualized using absorption contrast mode. The X-ray images of the cells could be used to study the spatial distributions of the organelles in the cells. These results show unique structural information, demonstrating that hard X-ray microscopy is a complementary method for imaging and analyzing biological samples.

  6. Laboratory source based full-field x-ray microscopy at 9 keV

    Energy Technology Data Exchange (ETDEWEB)

    Fella, C.; Balles, A.; Wiest, W. [Lehrstuhl für Röntgenmikroskopie, Julius-Maximilians-Universität, 97074 Würzburg (Germany); Zabler, S.; Hanke, R. [Lehrstuhl für Röntgenmikroskopie, Julius-Maximilians-Universität, 97074 Würzburg (Germany); Fraunhofer Development Center X-Ray Technology (EZRT), Flugplatzstrasse 75, 90768 Fürth (Germany)

    2016-01-28

    In the past decade, hard x-ray transmission microscopy experienced tremendous developments. With the avail-ability of efficient Fresnel zone plates, even set-ups utilizing laboratory sources were developed [1]. In order to improve the performance of these x-ray microscopes, novel approaches to fabricate optical elements [2] and brighter x-ray tubes [3] are promising candidates. We are currently building a laboratory transmission x-ray microscope for 9.25 keV, using an electron impact liquid-metal-jet anode source. Up to now, the further elements of our setup are: a polycapillary condenser, a tungsten zone plate, and a scintillator which is optically coupled to a CMOS camera. However, further variations in terms of optical elements are intended. Here we present the current status of our work, as well as first experimental results.

  7. Streaked, x-ray-transmission-grating spectrometer

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  8. New Observations of Soft X-ray (0.5-5 keV) Solar Spectra

    Science.gov (United States)

    Caspi, A.; Woods, T. N.; Mason, J. P.; Jones, A. R.; Warren, H. P.

    2013-12-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable on many time scales. However, the actual solar soft X-ray (SXR) (0.5-5 keV) spectrum is not well known, particularly during solar quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include high-resolution but very narrow-band spectra from crystal spectrometers (e.g., Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g., GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with moderate energy resolution (~0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and SAX on MESSENGER, although they did not extend to energies below ~1 keV. We present observations of solar SXR emission obtained using new instrumentation flown on recent SDO/EVE calibration rocket underflights. The photon-counting spectrometer, a commercial Amptek X123 with a silicon drift detector and an 8 μm Be window, measures the solar disk-integrated SXR emission from ~0.5 to >10 keV with ~0.15 keV FWHM resolution and 1 s cadence. A novel imager, a pinhole X-ray camera using a cooled frame-transfer CCD (15 μm pixel pitch), Ti/Al/C filter, and 5000 line/mm Au transmission grating, images the full Sun in multiple spectral orders from ~0.1 to ~5 nm with ~10 arcsec/pixel and ~0.01 nm/pixel spatial and spectral detector scales, respectively, and 10 s cadence. These instruments are prototypes for future CubeSat missions currently being developed. We present new results of solar observations on 04 October 2013 (NASA sounding rocket 36.290). We compare with previous results from 23 June 2012 (NASA sounding rocket 36.286), during which solar activity was low and no signal was observed above ~4 keV. We compare our spectral and imaging measurements with spectra and broadband irradiances from other instruments, including SDO/EVE, GOES/XRS, TIMED

  9. Picosecond x-ray measurements from 100 eV to 30 keV

    International Nuclear Information System (INIS)

    Attwood, D.T.; Kauffman, R.L.; Stradling, G.L.

    1980-01-01

    Picosecond x-ray measurements relevant to the Livermore Laser Fusion Program are reviewed. Resolved to 15 picoseconds, streak camera detection capabilities extend from 100 eV to higher than 30 keV, with synchronous capabilities in the visible, near infrared, and ultraviolet. Capabilities include automated data retrieval using charge coupled devices (CCD's), absolute x-ray intensity levels, novel cathodes, x-ray mirror/reflector combinations, and a variety of x-ray imaging devices

  10. X-ray spectrometer having 12 000 resolving power at 8 keV energy

    Science.gov (United States)

    Seely, John F.; Hudson, Lawrence T.; Henins, Albert; Feldman, Uri

    2017-10-01

    An x-ray spectrometer employing a thin (50 μm) silicon transmission crystal was used to record high-resolution Cu Kα spectra from a laboratory x-ray source. The diffraction was from the (331) planes that were at an angle of 13.26° to the crystal surface. The components of the spectral lines resulting from single-vacancy (1s) and double-vacancy (1s and 3d) transitions were observed. After accounting for the natural lifetime widths from reference double-crystal spectra and the spatial resolution of the image plate detector, the intrinsic broadening of the transmission crystal was measured to be as small as 0.67 eV and the resolving power 12 000, the highest resolving power achieved by a compact (0.5 m long) spectrometer employing a single transmission crystal operating in the hard x-ray region. By recording spectra with variable source-to-crystal distances and comparing to the calculated widths from various geometrical broadening mechanisms, the primary contributions to the intrinsic crystal broadening were found to be the source height at small distances and the crystal apertured height at large distances. By reducing these two effects, using a smaller source size and vignetting the crystal height, the intrinsic crystal broadening is then limited by the crystal thickness and the rocking curve width and would be 0.4 eV at 8 keV energy (20 000 resolving power).

  11. K X-Ray production cross sections for 40-180 keV protons

    International Nuclear Information System (INIS)

    Szegedi, S.; Hassan, M.F.

    2002-01-01

    In view of the importance of the X-ray production cross-section for the determination of element concentration in a given material, we have measured them experimentally for light elements Sc and Fe using proton beams of energy between 40 and 180 keV. The obtained K X-ray production cross-section is compared with the previous experimental results. The experimental K X-ray production cross-section for proton induced X-ray emission (PIXE) analysis, using low energy (200 keV) accelerator, have been improved

  12. Diffuse cosmic x-rays below 1 keV

    International Nuclear Information System (INIS)

    Kraushaar, W.L.

    1973-01-01

    A description of those features of the low energy diffuse x-ray flux on which there is general observational agreement is given. Most of the discussion is restricted to the energy region below 280 eV, the carbon K edge. Topics include intensity, spatial structure, nature of the local emission, and the extragalactic component. It is concluded that the diffuse soft x-ray measurements cannot, taken alone, be said to provide positive evidence for a hot dense intergalactic medium. (U.S.)

  13. Bragg concentrators for hard (> 10 keV) X-ray astronomy: Status report

    Energy Technology Data Exchange (ETDEWEB)

    Pareschi, G.; Pasqualini, G. [Ferrara, Univ. (Italy). Dipt. di Fisica; Frontera, F. [CNR, Bologna (Italy). Istituto di TESRE]|[Ferrara, Univ. (Italy). Dipt. di Fisica

    1997-09-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. They present recent results obtained from their group regarding the possible use of Bragg-diffraction technique to design hard X-ray focusing telescopes.

  14. Bragg concentrators for hard (> 10 keV) X-ray astronomy: Status report

    International Nuclear Information System (INIS)

    Pareschi, G.; Pasqualini, G.; Frontera, F.; Ferrara, Univ.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. They present recent results obtained from their group regarding the possible use of Bragg-diffraction technique to design hard X-ray focusing telescopes

  15. Pixelated transmission-mode diamond X-ray detector.

    Science.gov (United States)

    Zhou, Tianyi; Ding, Wenxiang; Gaowei, Mengjia; De Geronimo, Gianluigi; Bohon, Jen; Smedley, John; Muller, Erik

    2015-11-01

    Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60-100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ∼ 1 kHz, which leads to an image sampling rate of ∼ 30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5-15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10(-2) to 90 W mm(-2). Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).

  16. Patient size and x-ray transmission in body CT.

    Science.gov (United States)

    Ogden, Kent; Huda, Walter; Scalzetti, Ernest M; Roskopf, Marsha L

    2004-04-01

    Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.

  17. Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

    Science.gov (United States)

    Shridhar, Ravi; Estabrook, William; Yudelev, Mark; Rakowski, Joseph; Burmeister, Jay; Wilson, George D; Joiner, Michael C

    2010-03-01

    Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

  18. Characteristic K-shell x-ray production by protons below 500 keV

    International Nuclear Information System (INIS)

    Wheeler, R.M.; Chaturvedi, R.P.; Zander, A.R.

    1974-01-01

    The total thick target yield of K-shell x-rays produced in Ni by incident protons over the energy range 90 to 415 keV was measured. Similar measurements with 130 to 415 keV protons were made for Ti, Mn, Fe, Cu, and Zn. The East Texas State University 150 keV Cockcroft--Walton accelerator was used to study Ni K-shell x-rays produced by 90 to 150 keV protons. The remaining data were taken with the SUNY College at Cortland 400 keV Van de Graaff generator. The characteristic x-rays were measured with high resolution Si(Li) detectors. Using the most recent values of K-shell fluorescent yields, x-ray ionization cross sections were calculated and compared to theoretical predictions based on the binary encounter approximation (BEA) model. It was found that even though the data were lower than those expected by the BEA theory, they lie on a universal curve. A comprehensive summary of x-ray ionization cross section references covering the proton energy range up to 500 keV is also included. Possible applications of low energy accelerators (E/sub p/ less than or equal to 500 keV) for further experimental work is discussed

  19. X-ray transmission movies of spontaneous dynamic events

    International Nuclear Information System (INIS)

    Smilowitz, L.; Henson, B. F.; Holmes, M.; Novak, A.; Oschwald, D.; Dolgonos, P.; Qualls, B.

    2014-01-01

    We describe a new x-ray radiographic imaging system which allows for continuous x-ray transmission imaging of spontaneous dynamic events. We demonstrate this method on thermal explosions in three plastic bonded formulations of the energetic material octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine. We describe the x-ray imaging system and triggering developed to enable the continuous imaging of a thermal explosion

  20. Bragg concentrators for hard (> 10keV) x-ray astronomy: Status report

    DEFF Research Database (Denmark)

    Pareschi, G.; Frontera, F.; Pasqualini, G.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg-diffraction tec......The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg...

  1. W/SiC X-ray multilayers optimized for use above 100 keV

    DEFF Research Database (Denmark)

    Windt, D.L.; Dongey, S.; Hailey, C.J.

    2002-01-01

    -derived optical constants, which we determined from reflectance-vs-incidence angle measurements also made using synchrotron radiation, in the range E=120 - 180 keV. We describe our experimental investigation in detail, compare the new W/SiC multilayers with both W/Si and W/B4C films that have been studied......We have developed a new depth-graded multilayer system comprising W and SiC layers, suitable for use as hard X-ray reflective coatings operating in the energy range 100 - 200 keV. Grazing incidence X-ray reflectance at E=8 keV was used to characterize the interface widths, as well as the temporal...... and thermal stability in both periodic and depth-graded W/SiC structures, while synchrotron radiation was used to measure the hard X-ray reflectance of a depth-graded multilayer designed specifically for use in the range Esimilar to150 - 170 keV. We have modeled the hard X-ray reflectance using newly...

  2. W/SiC x-ray multilayers optimized for use above 100 keV

    DEFF Research Database (Denmark)

    Windt, D.L.; Donguy, S.; Hailey, C.J.

    2003-01-01

    optical constants, which we determined from reflectance versus incidence angle measurements also made using synchrotron radiation, in the range E = 120-180 keV. We describe our experimental investigation in detail, compare the new W/SiC multilayers with both W/Si and W/B4C films that have been studied......We have developed a new depth-graded multilayer system comprising W and SiC layers, suitable for use as hard x-ray reflective coatings operating in the energy range 100-200 keV. Grazing-incidence x-ray reflectance at E = 8 keV was used to characterize the interface widths, as well as the temporal...... and thermal stability in both periodic and depth-graded W/SiC structures, whereas synchrotron radiation was used to measure the hard x-ray reflectance of a depth-graded multilayer designed specifically for use in, the range Esimilar to150-170 keV. We have modeled the hard x-ray reflectance using newly derived...

  3. The 7 keV axion dark matter and the X-ray line signal

    Energy Technology Data Exchange (ETDEWEB)

    Higaki, Tetsutaro [KEK, Tsukuba (Japan). Theory Center; Jeong, Kwang Sik [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Takahashi, Fuminobu [Tohoku Univ., Sendai (Japan). Dept. of Physics; Tokyo Univ., Kashiwa (Japan). Kavli IPMU, TODIAS

    2014-03-15

    We propose a scenario where the saxion dominates the energy density of the Universe and reheats the standard model sector via the dilatonic coupling, while its axionic partner contributes to dark matter decaying into photons via the same operator in supersymmetry. Interestingly, for the axion mass m{sub a} ≅ 7 keV and the decay constant f{sub a} ≅10{sup 14-15} GeV, the recently discovered X-ray line at 3.5 keV in the XMM Newton X-ray observatory data can be explained. We discuss various cosmological aspects of the 7 keV axion dark matter such as the production of axion dark matter, the saxion decay process, hot dark matter and isocurvature constraints on the axion dark matter, and the possible baryogenesis scenarios.

  4. The 7 keV axion dark matter and the X-ray line signal

    International Nuclear Information System (INIS)

    Higaki, Tetsutaro; Takahashi, Fuminobu; Tokyo Univ., Kashiwa

    2014-03-01

    We propose a scenario where the saxion dominates the energy density of the Universe and reheats the standard model sector via the dilatonic coupling, while its axionic partner contributes to dark matter decaying into photons via the same operator in supersymmetry. Interestingly, for the axion mass m a ≅ 7 keV and the decay constant f a ≅10 14-15 GeV, the recently discovered X-ray line at 3.5 keV in the XMM Newton X-ray observatory data can be explained. We discuss various cosmological aspects of the 7 keV axion dark matter such as the production of axion dark matter, the saxion decay process, hot dark matter and isocurvature constraints on the axion dark matter, and the possible baryogenesis scenarios.

  5. MULTI-KEV X-Ray Yields From High-Z Gas Targets Fielded At Omega

    International Nuclear Information System (INIS)

    Kane, J.O.; Fournier, K.B.; May, M.J.; Colvin, J.D.; Thomas, C.A.; Marrs, R.E.; Compton, S.M.; Moody, J.D.; Bond, E.J.; Davis, J.F.

    2010-01-01

    The authors report on modeling of x-ray yield from gas-filled targets shot at the OMEGA laser facility. The OMEGA targets were 1.8 mm long, 1.95 mm in diameter Be cans filled with either a 50:50 Ar:Xe mixture, pure Ar, pure Kr or pure Xe at ∼ 1 atm. The OMEGA experiments heated the gas with 20 kJ of 3ω (∼ 350 nm) laser energy delivered in a 1 ns square pulse. the emitted x-ray flux was monitored with the x-ray diode based DANTE instruments in the sub-keV range. Two-dimensional x-ray images (for energies 3-5 keV) of the targets were recorded with gated x-ray detectors. The x-ray spectra were recorded with the HENWAY crystal spectrometer at OMEGA. Predictions are 2D r-z cylindrical with DCA NLTE atomic physics. Models generally: (1) underpredict the Xe L-shell yields; (2) overpredict the Ar K-shell yields; (3) correctly predict the Xe thermal yields; and (4) greatly underpredict the Ar thermal yields. However, there are spreads within the data, e.g. the DMX Ar K-shell yields are correctly predicted. The predicted thermal yields show strong angular dependence.

  6. Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

    Science.gov (United States)

    Takeda, Tohoru; Wu, Jin; Tsuchiya, Yoshinori; Yoneyama, Akio; Lwin, Thet-Thet; Hyodo, Kazuyuki; Itai, Yuji

    2004-05-01

    Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen.

  7. Bragg transmission phase plates for the production of circularly polarized x-rays

    International Nuclear Information System (INIS)

    Lang, J.C.; Srajer, G.

    1994-01-01

    A thin-crystal Si (400) Bragg transmission x-ray phase plate has been constructed for the production of 5 to 12 keV circularly polarized x-rays. Using multiple beam diffraction from a GaAs crystal, a direct measurement of the degree of circular polarization as a function of off-Bragg position was made. These measurements indicated nearly complete circular polarization (|P c | ≥ 0.95) and full helicity reversal on opposite sides of the rocking curve

  8. Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL

    International Nuclear Information System (INIS)

    Liu, Y.; Andrews, J. C.; Mehta, A.; Pianetta, P.; Meirer, F.; Gil, S. Carrasco; Sciau, P.; Mester, Z.

    2011-01-01

    State-of-the-art hard x-ray full-field transmission x-ray microscopy (TXM) at beamline 6-2C of Stanford Synchrotron Radiation Lightsource has been applied to various research fields including biological, environmental, and material studies. With the capability of imaging a 32-micron field-of-view at 30-nm resolution using both absorption mode and Zernike phase contrast, the 3D morphology of yeast cells grown in gold-rich media was investigated. Quantitative evaluation of the absorption coefficient was performed for mercury nanoparticles in alfalfa roots exposed to mercury. Combining XANES and TXM, we also performed XANES-imaging on an ancient pottery sample from the Roman pottery workshop at LaGraufesenque (Aveyron).

  9. Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL

    Science.gov (United States)

    Liu, Y.; Andrews, J. C.; Meirer, F.; Mehta, A.; Gil, S. Carrasco; Sciau, P.; Mester, Z.; Pianetta, P.

    2011-09-01

    State-of-the-art hard x-ray full-field transmission x-ray microscopy (TXM) at beamline 6-2C of Stanford Synchrotron Radiation Lightsource has been applied to various research fields including biological, environmental, and material studies. With the capability of imaging a 32-micron field-of-view at 30-nm resolution using both absorption mode and Zernike phase contrast, the 3D morphology of yeast cells grown in gold-rich media was investigated. Quantitative evaluation of the absorption coefficient was performed for mercury nanoparticles in alfalfa roots exposed to mercury. Combining XANES and TXM, we also performed XANES-imaging on an ancient pottery sample from the Roman pottery workshop at LaGraufesenque (Aveyron).

  10. Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source

    International Nuclear Information System (INIS)

    Donath, Tilman; Bunk, Oliver; Groot, Waldemar; Bednarzik, Martin; Gruenzweig, Christian; David, Christian; Pfeiffer, Franz; Hempel, Eckhard; Popescu, Stefan; Hoheisel, Martin

    2009-01-01

    Phase-contrast imaging at laboratory-based x-ray sources using grating interferometers has been developed over the last few years for x-ray energies of up to 28 keV. Here, we show first phase-contrast projection and tomographic images recorded at significantly higher x-ray energies, produced by an x-ray tube source operated at 100 kV acceleration voltage. We find our measured tomographic phase images in good agreement with tabulated data. The extension of phase-contrast imaging to this significantly higher x-ray energy opens up many applications of the technique in medicine and industrial nondestructive testing.

  11. Using angular dispersion and anomalous transmission to shape ultramonochromatic x rays

    Energy Technology Data Exchange (ETDEWEB)

    Shvyd' ko, Yuri; Stoupin, Stanislav; Shu, Deming; Khachatryan, Ruben [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2011-11-15

    Optical spectrometers, instruments that work with highly monochromatic light, are commonly rated by the spectral bandwidth, which defines the ability to resolve closely spaced spectral components. Another equally important feature is the spectral contrast, the ability to detect faint objects among these components. Here we demonstrate that a combined effect of angular dispersion (AD) and anomalous transmission (AT) of x rays in Bragg reflection from asymmetrically cut crystals can shape spectral distributions of x rays to profiles with high contrast and small bandwidths. The AD and AT x-ray optics is implemented as a five-reflection, three-crystal arrangement featuring a combination of the above-mentioned attributes so desirable for x-ray monochromators and analyzers: a spectral contrast of {approx_equal} 500, a bandwidth of {approx_equal} 0.46 meV, and a remarkably large angular acceptance of {approx_equal} 107 {mu}rad with 9.1 keV x rays. The new optics can become a foundation for the next-generation inelastic x-ray scattering spectrometers for studies of atomic dynamics.

  12. Research on temperature measurement by X-ray transmission intensity

    International Nuclear Information System (INIS)

    Chen, Shuyue; Cheng, Rong

    2013-01-01

    The relationship between temperature and X-ray transmission intensity was researched and analyzed by inspecting material density change, which is caused by thermal expansion. A digital radiographic system was employed to obtain the images. On this basis, we deduced the temperature formula based on the average gray level of the captured images. The measured temperatures were obtained from the experiments and the errors were analyzed. We concluded that when X-rays pass through an object, the X-ray strength and the gray level of the image under high temperatures are greater than those under lower temperatures and the image gray level error has great impact on the accuracy of the measured temperature. The presented approach allowed the non-contact temperature measurement of material

  13. Analytical device for X-ray tomography by transmission

    International Nuclear Information System (INIS)

    Allemand, Robert.

    1975-01-01

    The invention concerns an analytical system for X ray tomography by transmission. The principle of these appliances is based on measuring the absorption of an X ray beam in terms of the density of the tissue being examined. In the apparatus marketed by E.M.I. (Electric and Musical Industries Ltd) of Great Britain, one hundred absorption determinations are performed during a scan lasting around one second; with this apparatus the number of scans is 180. In order to extend this examination to organs other than the brain, it is necessary to use shorter examination times. To do so, the detection cells employed are ionization chambers and they are associated with instrumentation for determining the charge collected in each chamber over a given time under the effect of the X rays which have passed through the organ being examined [fr

  14. Efficient focusing of 8 keV X-rays with multilayer Fresnel zone plates fabricated by atomic layer deposition and focused ion beam milling

    International Nuclear Information System (INIS)

    Mayer, Marcel; Keskinbora, Kahraman; Grévent, Corinne; Szeghalmi, Adriana; Knez, Mato; Weigand, Markus; Snigirev, Anatoly; Snigireva, Irina; Schütz, Gisela

    2013-01-01

    The fabrication and performance of multilayer Al 2 O 3 /Ta 2 O 5 Fresnel zone plates in the hard X-ray range and a discussion of possible future developments considering available materials are reported. Fresnel zone plates (FZPs) recently showed significant improvement by focusing soft X-rays down to ∼10 nm. In contrast to soft X-rays, generally a very high aspect ratio FZP is needed for efficient focusing of hard X-rays. Therefore, FZPs had limited success in the hard X-ray range owing to difficulties of manufacturing high-aspect-ratio zone plates using conventional techniques. Here, employing a method of fabrication based on atomic layer deposition (ALD) and focused ion beam (FIB) milling, FZPs with very high aspect ratios were prepared. Such multilayer FZPs with outermost zone widths of 10 and 35 nm and aspect ratios of up to 243 were tested for their focusing properties at 8 keV and shown to focus hard X-rays efficiently. This success was enabled by the outstanding layer quality thanks to ALD. Via the use of FIB for slicing the multilayer structures, desired aspect ratios could be obtained by precisely controlling the thickness. Experimental diffraction efficiencies of multilayer FZPs fabricated via this combination reached up to 15.58% at 8 keV. In addition, scanning transmission X-ray microscopy experiments at 1.5 keV were carried out using one of the multilayer FZPs and resolved a 60 nm feature size. Finally, the prospective of different material combinations with various outermost zone widths at 8 and 17 keV is discussed in the light of the coupled wave theory and the thin-grating approximation. Al 2 O 3 /Ir is outlined as a promising future material candidate for extremely high resolution with a theoretical efficiency of more than 20% for as small an outermost zone width as 10 nm at 17 keV

  15. Measurement of the G-value for 1. 5 keV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, J.P.; Schillaci, M.E.; Raju, M.R. (Los Alamos National Lab., NM (USA))

    1989-12-01

    Using a ferrous sulfate solution modified by the addition of benzoic acid, the authors measured relative G-values for Al{sub k} characteristic X-rays (1.5keV), {sup 238}Pu {alpha}-particles (3.7MeV), {sup 60}Co (1.17 MeV) and {sup 137}Cs (0.66 MeV){gamma}-rays. Relative ferrous-to-ferric conversions as a function of dose were similar for the two {gamma}-ray energies, yielding G-values of 1.62 and 1.59 {mu}mol J{sup -1} for the {sup 60}Co and {sup 137}Cs radiations. The {alpha}-particle G-value was 0.52 {mu}mol J{sup -1}, or 31% of that for {sup 60}Co {gamma}-rays. The Al{sub k} X-rays had a G-value of 0.92 {mu}mol J{sup -1} or 57% of that of the {sup 60}Co radiation. This G-value for 1.5 keV X-rays is within 20% of values predicted by current theories, and theoretical values are within the error range of the authors' measurements. (author).

  16. Soft X-ray scanning transmission X-ray microscopy (STXM) of actinide particles.

    Science.gov (United States)

    Nilsson, Hans J; Tyliszczak, Tolek; Wilson, Richard E; Werme, Lars; Shuh, David K

    2005-09-01

    A descriptive account is given of our most recent research on the actinide dioxides with the Advanced Light Source Molecular Environmental Science (ALS-MES) Beamline 11.0.2 soft X-ray scanning transmission X-ray microscope (STXM) at the Lawrence Berkeley National Laboratory (LBNL). The ALS-MES STXM permits near-edge X-ray absorption fine structure (NEXAFS) and imaging with 30-nm spatial resolution. The first STXM spectromicroscopy NEXAFS spectra at the actinide 4d5/2 edges of the imaged transuranic particles, NpO2 and PuO2, have been obtained. Radiation damage induced by the STXM was observed in the investigation of a mixed oxidation state particle (Np(V,VI)) and was minimized during collection of the actual spectra at the 4d5/2 edge of the Np(V,VI) solid. A plutonium elemental map was obtained from an irregular PuO2 particle with the dimensions of 650 x 650 nm. The Pu 4d5/2 NEXAFS spectra were collected at several different locations from the PuO2 particle and were identical. A representative oxygen K-edge spectrum from UO2 was collected and resembles the oxygen K-edge from the bulk material. The unique and current performance of the ALS-MES STXM at extremely low energies (ca. 100 eV) that may permit the successful measurement of the actinide 5d edge is documented. Finally, the potential of STXM as a tool for actinide investigations is briefly discussed.

  17. Characterizing automotive fuel cell materials by soft x-ray scanning transmission x-ray microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hitchcock, A. P., E-mail: aph@mcmaster.ca; Lee, V.; Wu, J.; Cooper, G. [Chemistry & Chemical Biology, McMaster University, Hamilton, ON, L8S 4M1 (Canada); West, M. M.; Berejnov, V. [Faculty of Health Sciences Electron Microscopy, McMaster University, Hamilton, ON L8N 3Z5 (Canada); Soboleva, T.; Susac, D.; Stumper, J. [Automotive Fuel Cell Cooperation Corp., Burnaby BC V5J 5J8 (Canada)

    2016-01-28

    Proton-Exchange Membrane Fuel Cell (PEM-FC) based engines are being developed rapidly for near-term implementation in hydrogen fueled, mass production, personal automobiles. Research is focused on understanding and controlling various degradation processes (carbon corrosion, Pt migration, cold start), and reducing cost by reducing or eliminating Pt catalyst. We are using soft X-ray scanning transmission X-ray microscopy (STXM) at the S 2p, C 1s, O 1s and F 1s edges to study a variety of issues related to optimization of PEM-FC materials for automotive applications. A method to efficiently and accurately measure perfluorosulfonic acid distributions was developed and is being used to better understand how different loadings and preparation methods affect the ionomer distribution in the cathode. Progress towards an environmental cell capable of controlling the temperature and humidity of a PEM-FC sample in the STXM is described. Methods for studying the 3D chemical structure of PEM-FC are outlined.

  18. Characterizing automotive fuel cell materials by soft x-ray scanning transmission x-ray microscopy

    International Nuclear Information System (INIS)

    Hitchcock, A. P.; Lee, V.; Wu, J.; Cooper, G.; West, M. M.; Berejnov, V.; Soboleva, T.; Susac, D.; Stumper, J.

    2016-01-01

    Proton-Exchange Membrane Fuel Cell (PEM-FC) based engines are being developed rapidly for near-term implementation in hydrogen fueled, mass production, personal automobiles. Research is focused on understanding and controlling various degradation processes (carbon corrosion, Pt migration, cold start), and reducing cost by reducing or eliminating Pt catalyst. We are using soft X-ray scanning transmission X-ray microscopy (STXM) at the S 2p, C 1s, O 1s and F 1s edges to study a variety of issues related to optimization of PEM-FC materials for automotive applications. A method to efficiently and accurately measure perfluorosulfonic acid distributions was developed and is being used to better understand how different loadings and preparation methods affect the ionomer distribution in the cathode. Progress towards an environmental cell capable of controlling the temperature and humidity of a PEM-FC sample in the STXM is described. Methods for studying the 3D chemical structure of PEM-FC are outlined

  19. Static and time-resolved 10-1000 keV x-ray imaging detector options for NIF

    International Nuclear Information System (INIS)

    Landen, O.L.; Bell, P.M.; McDonald, J.W.; Park, H.-S.; Weber, F.; Moody, J.D.; Lowry, M.E.; Stewart, R.E.

    2004-01-01

    High energy (>10 keV) x-ray self-emission imaging and radiography will be essential components of many NIF high energy density physics experiments. In preparation for such experiments, we have evaluated the pros and cons of various static [x-ray film, bare charge-coupled device (CCD), and scintillator + CCD] and time-resolved (streaked and gated) 10-1000 keV detectors

  20. A high resolution reflecting crystal spectrometer to measure 3 keV pionic hydrogen and deuterium X-rays

    International Nuclear Information System (INIS)

    Badertscher, A.; Bogdan, M.; Goudsmit, P.F.A.; Knecht, L.; Leisi, H.J.; Schroeder, H.C.; Sigg, D.; Zhao, Z.G.; Chatellard, D.; Egger, J.P.; Jeannet, E.; Aschenauer, E.C.; Gabathuler, K.; Simons, L.M.; Rusi El Hassani, A.J.

    1993-01-01

    A reflecting crystal spectrometer consisting of three cylindrically bent quartz (110) crystals is described. It was designed to measure the 3 keV K β X-rays from pionic hydrogen and deuterium. Charge coupled devices (CCDs) were used as X-ray detectors. Projecting the reflexes of all three crystals on one common focus, an instrumental energy resolution below 1 eV was obtained at an energy of 2.9 keV. (orig.)

  1. Extension to Low Energies (<7keV) of High Pressure X-Ray Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Itie, J.-P.; Flank, A.-M.; Lagarde, P.; Idir, M.; Polian, A.; Couzinet, B.

    2007-01-01

    High pressure x-ray absorption has been performed down to 3.6 keV, thanks to the new LUCIA beamline (SLS, PSI) and to the use of perforated diamonds or Be gasket. Various experimental geometries are proposed, depending on the energy of the edge and on the concentration of the studied element. A few examples will be presented: BaTiO3 at the titanium K edge, Zn0.95 Mn0.05O at the manganese K edge, KCl at the potassium K edge

  2. X-ray fluorescence in some medium-Z elements excited by 59.5 keV photons

    International Nuclear Information System (INIS)

    Han, I.; Shahin, M.; Demir, L.; Narmanli, E.

    2010-01-01

    K X-ray fluorescence parameters cross sections and average shell fluorescence yields) for selected ten elements in the atomic range 42 ≤ Z ≤ 66 have been experimentally determined at photon excitation energy of 59.5 keV. K X-rays emitted from the samples have been counted by a Si (Li) detector. The K spectra for investigated elements have been derived from the measured K shell X-ray spectra by peak fitting process. Experimental results of K X-ray fluorescence parameters have been compared with theory. In general there is an agreement within the standard uncertainties of the experimental and theoretical values

  3. X-ray absorption spectroscopy in the keV range with laser generated high harmonic radiation

    International Nuclear Information System (INIS)

    Seres, Enikoe; Seres, Jozsef; Spielmann, Christian

    2006-01-01

    By irradiating He and Ne atoms with 3 mJ, 12 fs, near infrared laser pulses from a tabletop laser system, the authors generated spatially and temporally coherent x rays up to a photon energy of 3.5 keV. With this source it is possible to use high-harmonic radiation for x-ray absorption spectroscopy in the keV range. They were able to clearly resolve the L absorption edges of titanium and copper and the K edges of aluminum and silicon. From the fine structure of the x-ray absorption they estimated the interatomic distances

  4. EMISSION LINES BETWEEN 1 AND 2 keV IN COMETARY X-RAY SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Ian; Christian, Damian J. [Department of Physics and Astronomy, California State University, 18111 Nordhoff Street, Northridge, CA 91330 (United States); Bodewits, Dennis [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Dennerl, Konrad [Max-Planck-Institut fuer extraterrestrische Physik, Postfach 1312, D-85741 Garching Germany (Germany); Lisse, Carey M. [Planetary Exploration Group, Space Department, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, MD 20723 (United States); Wolk, Scott J., E-mail: ian.ewing.794@my.csun.edu, E-mail: daman.christian@csun.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-01-20

    We present the detection of new cometary X-ray emission lines in the 1.0-2.0 keV range using a sample of comets observed with the Chandra X-Ray Observatory and ACIS spectrometer. We have selected five comets from the Chandra sample with good signal-to-noise spectra. The surveyed comets are C/1999 S4 (LINEAR), C/1999 T1 (McNaught-Hartley), 153P/2002 (Ikeya-Zhang), 2P/2003 (Encke), and C/2008 8P (Tuttle). We modeled the spectra with an extended version of our solar wind charge exchange (SWCX) emission model. Above 1 keV, we find Ikeya-Zhang to have strong emission lines at 1340 and 1850 eV which we identify as being created by SWCX lines of Mg XI and Si XIII, respectively, and weaker emission lines at 1470, 1600, and 1950 eV formed by SWCX of Mg XII, Mg XI, and Si XIV, respectively. The Mg XI and XII and Si XIII and XIV lines are detected at a significant level for the other comets in our sample (LS4, MH, Encke, 8P), and these lines promise additional diagnostics to be included in SWCX models. The silicon lines in the 1700-2000 eV range are detected for all comets, but with the rising background and decreasing cometary emission, we caution that these detections need further confirmation with higher resolution instruments.

  5. The detection of hard x-rays (10-140 KeV) by channel plate electron multipliers

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1976-12-01

    Results are presented indicating that hard X-rays in the energy range 10 to 50 keV can be detected with good efficiency (5 to 10%) in channel plate electron multipliers (CPEM). From 50 keV to 140 keV the detection efficiency lies in the range 1 to 2%. A simple physical model is developed which indicates that not only can good detection efficiency be obtained but that very good X-ray imaging is possible. The model predicts that with further development, a wideband, hard X-ray detector can be realised with a detection efficiency in the range 5 to 20% and spatial response better than 10 lp/mm in the energy range 10 to 140 keV. (author)

  6. A comparative study of the ionic keV X-ray line emission from ...

    Indian Academy of Sciences (India)

    resolved X-ray diffraction [15] etc. High conversion efficiency of the laser ... picosecond ionic X-ray pulses are produced when both the plasma density and the tem- ..... X-ray spectrum of magnesium plasma produced using femtosecond laser.

  7. Microstructural characterization of industrial foams by gamma ray transmission and X-ray microtomography

    International Nuclear Information System (INIS)

    Rodrigues, Luiz Eduardo

    2004-01-01

    This work presents the total porosity measurements of the aluminum and silicon carbide (SiC) foams samples. For porosity determination the gamma ray transmission and X-ray microtomography with conic beam techniques were used. These methods have more advantage than conventional ones, because they are non destructive and provide more details of the analyzed material porous structure. The aluminum foam samples with 10, 20, 30, 40 and 45 ppi (pores per inch) and SiC ceramic foam samples with 20, 30, 45, 60, 75, 80 and 90 ppi were analysed by gamma transmission. The SiC 60, 75 and 90 ppi samples were also analyzed by X-ray microtomography. For the gamma ray transmission measurements it was used an 241 Am source (59.53 keV), a NaI(Tl) scintillation detector, collimators, a XYZ micrometric table and standard gamma spectrometry electronics connected to a multichannel analyzer, at the LFNA/UEL. For the X-ray microtomographic measurements, the Fein Focus X-ray system of the Nuclear Instrumentation Laboratory of the COPPE, located at the Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, was used. This equipment provide us images with micrometric resolution (53.48 μm) using a conic X-ray beam and bidimensional detection. The microtomographic images were pre-processed and analyzed by the Imago software, developed at Porous Media and Materials Thermophysical Properties Laboratory (LMPT) of the Mechanical Engineering Department, located at Universidade Federal de Santa Catarina, Florianopolis, SC. Employing the The Imago software it was calculated the total porosity, pore size distribution and autocorrelation function C(u) of the binarized microtomographic images of the each sample. The microtomographic 3-D image of each sample was compared with 3-D image reconstructed by the Gaussian truncated method. This method generates a periodic 3-D porous structure by using of the autocorrelation function of one 2-D cross sectional image of the sample. (author)

  8. Calibration of hard x-ray (15 - 50 keV) optics at the MPE test facility PANTER

    Science.gov (United States)

    Bräuninger, Heinrich; Burkert, Wolfgang; Hartner, Gisela D.; Citterio, Oberto; Ghigo, Mauro; Mazzoleni, Francesco; Pareschi, Giovanni; Spiga, Daniele

    2004-02-01

    The Max-Planck-Institut für extraterrestrische Physik (MPE) in Garching, Germany, operates the large X-ray beam line facility PANTER for testing astronomical systems. At PANTER a number of telescopes like EXOSAT, ROSAT, SAX, JET-X, ABRIXAS, XMM and SWIFT operating in the soft energy range (0.02 - 15 keV) have been successfully calibrated. In the present paper we report on an important upgrade recently implemented that enables the calibration of hard X-ray optics (from 15 up to 50 keV). Currently hard X-ray optics based on single and multilayer coating are being developed for several future X-ray missions. The hard X-ray calibrations at PANTER are carried out by a high energy source based on an electron gun and several anodes, able to cover the energy range from 4.5 up to 50 keV. It provides fluxes up to 104 counts/sec/cm2 at the instrument chamber with a stability better than 1%. As detector a pn-CCD camera operating between 0.2 and 50 keV and a collecting area of 36 cm2 is used. Taking into account the high energy resolution of the CCD (145 eV at 6 keV), a very easy way to operate the facility in hard X-ray is in energy-dispersive mode (i.e. with a broad-band beam). A double crystal monochromator is also available providing energies up to 20 keV. In this paper we present the first results obtained by using PANTER for hard X-ray characterizations, performed on prototype multilayer optics developed by the Osservatorio Astronomico di Brera (OAB), Milano, Italy, and the Harvard-Smithsonian Center for Astrophysics (CfA), Cambridge, MA, USA.

  9. Cross section for induced L X-ray emission by protons of energy <400 keV

    International Nuclear Information System (INIS)

    Mohan, Harsh; Jain, Arvind Kumar; Kaur, Mandeep; Singh, Parjit S.; Sharma, Sunita

    2014-01-01

    In performing ion beam analysis, cross section for induced L X-ray emission plays a crucial role. There are different approaches by which these can be found experimentally or can be calculated theoretically based on various models. L X-ray production cross sections for Bi with protons in the energy range 260–400 keV at the interval of 20 keV are measured. These are compared with calculations obtained on the basis of current prevailing theories ECPSSR and ECPSSR-UA. Their importance in understanding this phenomenon and existing arguments in this regard will be highlighted

  10. Experimental time resolved measurement of fluence and energy spectra of photons emitted by a pulsed X-ray generator in the range 5-300 keV

    International Nuclear Information System (INIS)

    Vie, M.; Baboulet, J.P.

    1989-01-01

    We have developed: - A sensor to measure locally X ray fluence rate amplitude and variation versus time during X ray pulses, - A spectrometer based on ROSS method to measure absolute X ray spectrum versus time during X ray pulses. This metrology is used to characterise single shot X ray pulsed sources emitting photons in the range of 5 to 300 keV. Fluence domain is between 10 -9 and 5 10 -4 J. cm -2 with a few nanoseconds time resolution [fr

  11. NEW OBSERVATIONS OF THE SOLAR 0.5–5 KEV SOFT X-RAY SPECTRUM

    Energy Technology Data Exchange (ETDEWEB)

    Caspi, Amir; Woods, Thomas N. [Laboratory for Atmospheric and Space Physics, University of Colorado, Boulder, CO 80303 (United States); Warren, Harry P. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2015-03-20

    The solar corona is orders of magnitude hotter than the underlying photosphere, but how the corona attains such high temperatures is still not understood. Soft X-ray (SXR) emission provides important diagnostics for thermal processes in the high-temperature corona, and is also an important driver of ionospheric dynamics at Earth. There is a crucial observational gap between ∼0.2 and ∼4 keV, outside the ranges of existing spectrometers. We present observations from a new SXR spectrometer, the Amptek X123-SDD, which measured the spatially integrated solar spectral irradiance from ∼0.5 to ∼5 keV, with ∼0.15 keV FWHM resolution, during sounding rocket flights on 2012 June 23 and 2013 October 21. These measurements show that the highly variable SXR emission is orders of magnitude greater than that during the deep minimum of 2009, even with only weak activity. The observed spectra show significant high-temperature (5–10 MK) emission and are well fit by simple power-law temperature distributions with indices of ∼6, close to the predictions of nanoflare models of coronal heating. Observations during the more active 2013 flight indicate an enrichment of low first-ionization potential elements of only ∼1.6, below the usually observed value of ∼4, suggesting that abundance variations may be related to coronal heating processes. The XUV Photometer System Level 4 data product, a spectral irradiance model derived from integrated broadband measurements, significantly overestimates the spectra from both flights, suggesting a need for revision of its non-flare reference spectra, with important implications for studies of Earth ionospheric dynamics driven by solar SXRs.

  12. Precise rotational alignment of x-ray transmission diffraction gratings

    International Nuclear Information System (INIS)

    Hill, S.L.

    1988-01-01

    Gold transmission diffraction gratings used for x-ray spectroscopy must sometimes be rotationally aligned to the axis of a diagnostic instrument to within sub-milliradian accuracy. We have fabricated transmission diffraction gratings with high line-densities (grating period of 200 and 300 nm) using uv holographic and x-ray lithography. Since the submicron features of the gratings are not optically visible, precision alignment is time consuming and difficult to verify in situ. We have developed a technique to write an optically visible alignment pattern onto these gratings using a scanning electron microscope (SEM). At high magnification (15000 X) several submicron lines of the grating are observable in the SEM, making it possible to write an alignment pattern parallel to the grating lines in an electron-beam-sensitive coating that overlays the grating. We create an alignment pattern by following a 1-cm-long grating line using the SEM's joystick-controlled translation stage. By following the same grating line we are assured the traveled direction of the SEM electron beam is parallel to the grating to better than 10 μradian. The electron-beam-exposed line-width can be large (5 to 15 μm wide) depending on the SEM magnification, and is therefore optically visible. The exposed pattern is eventually made a permanent feature of the grating by ion beam etching or gold electroplating. The pattern can be used to accurately align the grating to the axis of a diagnostic instrument. More importantly, the alignment of the grating can be quickly verified in situ

  13. Heavy concerns about the light axino explanation of the 3.5 keV X-ray line

    CERN Document Server

    Colucci, Stefano; Staub, Florian; Ubaldi, Lorenzo

    2015-09-05

    An unidentified 3.5 keV line from X-ray observations of galaxy clusters has been reported recently. Although still under scrutiny, decaying dark matter could be responsible for this signal. We investigate whether an axino with a mass of 7 keV could explain the line, keeping the discussion as model independent as possible. We point out several obstacles, which were overlooked in the literature, and which make the axino an unlikely candidate.

  14. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  15. Transmission x-ray microscopy at Diamond-Manchester I13 Imaging Branchline

    Energy Technology Data Exchange (ETDEWEB)

    Vila-Comamala, Joan, E-mail: joan.vila.comamala@gmail.com; Wagner, Ulrich; Bodey, Andrew J.; Garcia-Fernandez, Miryam; Rau, Christoph [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); Bosgra, Jeroen; David, Christian [Paul Scherrer Institut, 5232 PSI-Villigen (Switzerland); Eastwood, David S. [Manchester X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL, UK and Research Complex at Harwell, Harwell Campus, Didcot OX11 0FA (United Kingdom)

    2016-01-28

    Full-field Transmission X-ray Microscopy (TXM) has been shown to be a powerful method for obtaining quantitative internal structural and chemical information from materials at the nanoscale. The installation of a Full-field TXM station will extend the current microtomographic capabilities of the Diamond-Manchester I13 Imaging Branchline at Diamond Light Source (UK) into the sub-100 nm spatial resolution range using photon energies from 8 to 14 keV. The dedicated Full-field TXM station will be built in-house with contributions of Diamond Light Source support divisions and via collaboration with the X-ray Optics Group of Paul Scherrer Institut (Switzerland) which will develop state-of-the-art diffractive X-ray optical elements. Preliminary results of the I13 Full-field TXM station are shown. The Full-field TXM will become an important Diamond Light Source direct imaging asset for material science, energy science and biology at the nanoscale.

  16. Transmission x-ray microscopy at Diamond-Manchester I13 Imaging Branchline

    International Nuclear Information System (INIS)

    Vila-Comamala, Joan; Wagner, Ulrich; Bodey, Andrew J.; Garcia-Fernandez, Miryam; Rau, Christoph; Bosgra, Jeroen; David, Christian; Eastwood, David S.

    2016-01-01

    Full-field Transmission X-ray Microscopy (TXM) has been shown to be a powerful method for obtaining quantitative internal structural and chemical information from materials at the nanoscale. The installation of a Full-field TXM station will extend the current microtomographic capabilities of the Diamond-Manchester I13 Imaging Branchline at Diamond Light Source (UK) into the sub-100 nm spatial resolution range using photon energies from 8 to 14 keV. The dedicated Full-field TXM station will be built in-house with contributions of Diamond Light Source support divisions and via collaboration with the X-ray Optics Group of Paul Scherrer Institut (Switzerland) which will develop state-of-the-art diffractive X-ray optical elements. Preliminary results of the I13 Full-field TXM station are shown. The Full-field TXM will become an important Diamond Light Source direct imaging asset for material science, energy science and biology at the nanoscale

  17. Transmission x-ray microscopy at Diamond-Manchester I13 Imaging Branchline

    Science.gov (United States)

    Vila-Comamala, Joan; Bosgra, Jeroen; Eastwood, David S.; Wagner, Ulrich; Bodey, Andrew J.; Garcia-Fernandez, Miryam; David, Christian; Rau, Christoph

    2016-01-01

    Full-field Transmission X-ray Microscopy (TXM) has been shown to be a powerful method for obtaining quantitative internal structural and chemical information from materials at the nanoscale. The installation of a Full-field TXM station will extend the current microtomographic capabilities of the Diamond-Manchester I13 Imaging Branchline at Diamond Light Source (UK) into the sub-100 nm spatial resolution range using photon energies from 8 to 14 keV. The dedicated Full-field TXM station will be built in-house with contributions of Diamond Light Source support divisions and via collaboration with the X-ray Optics Group of Paul Scherrer Institut (Switzerland) which will develop state-of-the-art diffractive X-ray optical elements. Preliminary results of the I13 Full-field TXM station are shown. The Full-field TXM will become an important Diamond Light Source direct imaging asset for material science, energy science and biology at the nanoscale.

  18. Low-energy x-ray dosimetry studies (6 to 16 keV) at SSRL beamline 1-5

    International Nuclear Information System (INIS)

    Ipe, N.E.; Chatterji, S.; Fassograve, A.; Kase, K.R.; Seefred, R.; Bilski, P.; Soares, C.

    1997-01-01

    Synchrotron radiation facilities provide a unique opportunity for low-energy x-ray dosimetry studies because of the availability of monochromatic x-ray beams. Results of such studies performed at the Stanford Synchrotron Radiation Laboratory (SSRL) are described. Polish lithium fluoride thermoluminescent dosemeters (TLDs), MTS-N(LiF:Mg, Ti- 0.4 mm thick), MCP-N (LiF:Mg, Cu, P - 0.4 mm thick) were exposed free in air to monochromatic x-rays (6 - 16 keV). These exposures were monitored with an SSRL ionization chamber. The responses (counts/Gy) of MTS-N and MCP-N were generally found to increase with increasing energy. The response at 16 keV is about 3 and 4 times higher than the response at 6 keV for MTS-N and MCP-N, respectively. Irradiation at 6 keV indicates a fairly linear dose response for both type of TLDs over a dose range of 0.01 to 0.4 Gy. In addition there appears to be no significant difference in responses between irradiating the TLDs from the front and the back sides. The energy response of the PTW ionization chamber type 23342 relative to the SSRL ionization chamber is within ±4.5% between 6 and 16 keV. Both the TLDs and the PTW ionization chamber can also be used for beam dosimetry. copyright 1997 American Institute of Physics

  19. Low-energy x-ray dosimetry studies (7 to 17.5 keV) with synchroton radiation

    International Nuclear Information System (INIS)

    Ipe, N.E.; Bellamy, H.; Flood, J.R.

    1995-06-01

    Unique properties of synchrotron radiation (SR), such as its high intensity, brightness, polarization, and broad spectral distribution (extending from x-ray to infra-red wavelengths) make it an attractive light source for numerous experiments. As SR facilities are rapidly being built all over the world, they introduce the need for low-energy x-ray dosemeters because of the potential radiation exposure to experimenters. However, they also provide a unique opportunity for low-energy x-ray dosimetry studies because of the availability of monochromatic x-ray beams. Results of such studies performed at the Stanford Synchrotron Radiation Laboratory are described. Lithium fluoride TLDs (TLD-100) of varying thicknesses (0.015 to 0.08 cm) were exposed free in air to monochromatic x-rays (7 to 17.5 keV). These exposures were monitored with ionization chambers. The response (nC/Gy) was found to increase with increasing TLD thickness and with increasing beam energy. A steeper increase in response with increasing energy was observed with the thicker TLDs. The responses at 7 and 17.5 keV were within a factor of 2.3 and 5.2 for the 0.015 and 0.08 cm-thick TLDs, respectively. The effects of narrow (beam size smaller than the dosemeter) and broad (beam size larger than the dosemeter) beams on the response of the TLDs are also reported

  20. An Einstein survey of the 1 keV soft X-ray background in the Galactic plane

    Science.gov (United States)

    Stanford, John M.; Caillault, Jean-Pierre

    1994-01-01

    We have analyzed 56 Einstein Observatory Imaging Proportional Counter (IPC) observations within +/- 3 deg of the Galactic plane in order to determine the low-latitude soft X-ray background flux in the 0.56-1.73 keV band. Any detected X-ray point source which fell within our regions of study was removed from the image, enabling us to present maps of the background flux as a function of Galactic latitude along 18 meridians. These maps reveal considerable structure to the background in the Galactic plane on an angular scale of approximately 1 deg. Our results are compared with those of an earlier study of the 1 keV X-ray background along l = 25 deg by Kahn & Caillault. The double-peaked structure they found is not discernible in our results, possibly because of the presence of solar backscattered flux in their data. A model which takes into account contributions to the background by extragalactic and stellar sources, the distribution of both atomic and molecular absorbing material with the Galaxy, the energy dependence of the cross section for absorption of X-rays, and the energy dependence of the detector has been constructed and fitted to these new data to derive constraints on the scale height, temperature, and volume emissivity of the unaccounted-for X-ray-emitting material. The results of this model along l = 25 deg are roughly similar to those of the model of Kahn & Caillault along the same meridian.

  1. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  2. Determination of tungsten target parameters for transmission X-ray tube: A simulation study using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Nasseri, Mohammad M. [School of Plasma Physics and Nuclear Fusion, Institute of Nuclear Science and Technology (AEOI), Tehran (Iran, Islamic Republic of)

    2016-06-15

    Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

  3. X-ray framing cameras for > 5 keV imaging

    International Nuclear Information System (INIS)

    Landen, O.L.; Bell, P.M.; Costa, R.; Kalantar, D.H.; Bradley, D.K.

    1995-01-01

    Recent and proposed improvements in spatial resolution, temporal resolution, contrast, and detection efficiency for x-ray framing cameras are discussed in light of present and future laser-plasma diagnostic needs. In particular, improvements in image contrast above hard x-ray background levels is demonstrated by using high aspect ratio tapered pinholes

  4. Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J. F., E-mail: seelyjf@gmail.com; Feldman, U. [Artep Inc., 2922 Excelsior Springs Court, Ellicott City, Maryland 21042 (United States); Glover, J. L.; Hudson, L. T.; Ralchenko, Y.; Henins, Albert [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Pereira, N. [Ecopulse Inc., P. O. Box 528, Springfield, Virginia 22152 (United States); Di Stefano, C. A.; Kuranz, C. C.; Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, Hui; Williams, G. J.; Park, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2014-11-15

    A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

  5. Final Report on Small Particle Speciation for Forensics Analysis by Soft X-ray Scanning Transmission X-ray Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pacold, J. I. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Altman, A. B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Donald, S B [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dai, Z. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Davisson, M. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Holliday, K S [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Knight, K. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kristo, M. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Minasian, S. G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nelson, A J [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tyliszczak, T [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Booth, C. H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shuh, D. K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-09-30

    Materials of interest for nuclear forensic science are often highly heterogeneous, containing complex mixtures of actinide compounds in a wide variety of matrices. Scanning transmission X-ray microscopy (STXM) is ideally suited to study such materials, as it can be used to chemically image specimens by acquiring X-ray absorption near-edge spectroscopy (XANES) data with 25 nm spatial resolution. In particular, STXM in the soft X-ray synchrotron radiation regime (approximately 120 – 2000 eV) can collect spectroscopic information from the actinides and light elements in a single experiment. Thus, STXM combines the chemical sensitivity of X-ray absorption spectroscopy with high spatial resolution in a single non-destructive characterization method. This report describes the application of STXM to a broad range of nuclear materials. Where possible, the spectroscopic images obtained by STXM are compared with information derived from other analytical methods, and used to make inferences about the process history of each material. STXM measurements can yield information including the morphology of a sample, “elemental maps” showing the spatial distribution of major chemical constituents, and XANES spectra from localized regions of a sample, which may show spatial variations in chemical composition.

  6. The physical and biomedical characteristics of the novel transmission type X-ray equipment

    International Nuclear Information System (INIS)

    Hsu, S.M.; Wang, S.F.; Hsieh, Y.J.; Cheng, C.C.; Liao, Y.J.

    2016-01-01

    The radiation output characteristics of the transmission-target X-ray tube are different from those of the traditional reflection-target X-ray tube. The aims of this study were to compare the differences of output dose and spectrum between these two X-ray tubes under the same conditions. The biomedical applications of the transmission-target X-ray in liver cancer cells were also evaluated. For these two systems, the dose output and the mAs appeared to have good linear relations; the dose output and kVp variations also had positive relations. However, under the same parameters, the dose output of transmission-target X-ray system was 2.64–3.21 times higher than the reflection-target system, implying that the transmission-target system had a higher X-ray production rate. The K characteristic radiations reach 22.96% and 8.91% of the spectrum in transmission-target and reflection-target, respectively. The spectrum measurements showed that the transmission-target system had more obvious output of K characteristic radiation. The 1 Gy of transmission-target can induce 16%–23% of cytotoxicity in liver cancer cells. Concerning the synergic effects of transmission-target combined with rose bengal, the data showed that 1 Gy of transmission-target exposure augment the 24%–28% of cytotoxicity at low dose of rose bengal treated condition. - Highlights: • The transmission-target X-ray system had a higher X-ray production rate. • The transmission-target X-ray system had more obvious output of K characteristic radiation. • The transmission-target X-ray enhanced rose bengal induced cytotoxicity in liver cancer cells.

  7. Photon-induced L X-ray production differential cross sections in thorium at 22.6 keV

    International Nuclear Information System (INIS)

    Puri, Sanjiv; Mehta, D.; Shahi, J.S.; Garg, M.L.; Singh, Nirmal; Trehan, P.N.

    1999-01-01

    The Ll, Lα, Lβ 2,4 , Lβ 1,3 and Lγ 1,5 X-ray production differential cross sections in 90 Th have been measured at 22.6 keV incident photon energy in an angular range 50-130 deg. The measurements were performed using a 109 Cd annular-source and a Si(Li) detector. The measured differential cross sections for various L X-rays are found to be angle-independent within experimental error. This is contrary to the strong angular-dependence of photon-induced Ll and Lα X-ray production cross sections as reported by Kahlon et al. (K.S. Kahlon, H.S. Aulakh, N. Singh, R. Mittal, K.L. Allawadhi, B.S. Sood, Phys. Rev. A 43 (1991) 1455) and Ertugrul (M. Ertugrul, Nucl. Instr. and Meth. B 119 (1996) 345). Integral cross sections for production of Ll, Lα, Lη, Lβ 6 , Lβ 2,4 , Lβ 1,3 , Lβ 9,10 , Lγ 1,5 and total Lγ X-rays are also deduced and are found to be in good agreement with those calculated using reliable theoretical values of the L i (i=1, 2, 3) subshell photoionisation cross sections, fluorescence yields, X-ray emission rates and Coster-Kronig transition probabilities

  8. Transmission X-ray microscopy for full-field nano-imaging of biomaterials

    Science.gov (United States)

    ANDREWS, JOY C; MEIRER, FLORIAN; LIU, YIJIN; MESTER, ZOLTAN; PIANETTA, PIERO

    2010-01-01

    Imaging of cellular structure and extended tissue in biological materials requires nanometer resolution and good sample penetration, which can be provided by current full-field transmission X-ray microscopic techniques in the soft and hard X-ray regions. The various capabilities of full-field transmission X-ray microscopy (TXM) include 3D tomography, Zernike phase contrast, quantification of absorption, and chemical identification via X-ray fluorescence and X-ray absorption near edge structure (XANES) imaging. These techniques are discussed and compared in light of results from imaging of biological materials including microorganisms, bone and mineralized tissue and plants, with a focus on hard X-ray TXM at ≤ 40 nm resolution. PMID:20734414

  9. Transmission X-ray microscopy for full-field nano imaging of biomaterials.

    Science.gov (United States)

    Andrews, Joy C; Meirer, Florian; Liu, Yijin; Mester, Zoltan; Pianetta, Piero

    2011-07-01

    Imaging of cellular structure and extended tissue in biological materials requires nanometer resolution and good sample penetration, which can be provided by current full-field transmission X-ray microscopic techniques in the soft and hard X-ray regions. The various capabilities of full-field transmission X-ray microscopy (TXM) include 3D tomography, Zernike phase contrast, quantification of absorption, and chemical identification via X-ray fluorescence and X-ray absorption near edge structure imaging. These techniques are discussed and compared in light of results from the imaging of biological materials including microorganisms, bone and mineralized tissue, and plants, with a focus on hard X-ray TXM at ≤ 40-nm resolution. Copyright © 2010 Wiley-Liss, Inc.

  10. Investigation of multilayer X-ray optics for 6 keV to 20 keV energy range

    Czech Academy of Sciences Publication Activity Database

    Oberta, Peter; Platonov, Y.; Flechsig, U.

    2012-01-01

    Roč. 19, č. 5 (2012), s. 675-681 ISSN 0909-0495 Institutional research plan: CEZ:AV0Z10100522 Keywords : X-ray optics * multilayer * energy resolution Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.186, year: 2012 http://journals.iucr.org/s/issues/2012/05/00/issconts.html

  11. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    International Nuclear Information System (INIS)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-01-01

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin

  12. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  13. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Science.gov (United States)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-12-01

    The "Commissariat à l'énergie atomique et aux énergies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  14. Accretion Properties of a Sample of Hard X-Ray (<60 keV) Selected Seyfert 1 Galaxies

    Science.gov (United States)

    Wang, J.; Mao, Y. F.; Wei, J. Y.

    2009-02-01

    We examine the accretion properties in a sample of 42 hard (3-60 keV) X-ray selected nearby broad-line active galactic nuclei (AGNs). The energy range in the sample is harder than that usually used in similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey, and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad Hβ emission line. The tight correlation between the hard X-ray (3-20 keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the Hβ emission line. In addition, all of these hard X-ray AGNs are biased toward luminous objects with a high Eddington ratio (mostly between 0.01 and 0.1) and a low column density (Simbol-X, and NeXT. Finally, the correlation between RFe (= optical Fe II/Hβ) and disk temperature as assessed by T vprop (L/L Edd)M -1 BH leads us to suggest that the strength of the Fe II emission is mainly determined by the shape of the ionizing spectrum.

  15. LABORATORY MEASUREMENTS COMPELLINGLY SUPPORT A CHARGE-EXCHANGE MECHANISM FOR THE “DARK MATTER” ∼3.5 keV X-Ray LINE

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chintan; Dobrodey, Stepan; Bernitt, Sven; Steinbrügge, René; López-Urrutia, José R. Crespo [Max-Planck-Institut für Kernphysik, Heidelberg, D-69117 Heidelberg (Germany); Gu, Liyi; Kaastra, Jelle [SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584 CA, Utrecht (Netherlands)

    2016-12-10

    The reported observations of an unidentified X-ray line feature at ∼3.5 keV have driven a lively discussion about its possible dark matter origin. Motivated by this, we have measured the K-shell X-ray spectra of highly ionized bare sulfur ions following charge exchange with gaseous molecules in an electron beam ion trap, as a source of or a contributor to this X-ray line. We produced S{sup 16+} and S{sup 15+} ions and let them capture electrons in collision with those molecules with the electron beam turned off while recording X-ray spectra. We observed a charge-exchange-induced X-ray feature at the Lyman series limit (3.47 ± 0.06 keV). The inferred X-ray energy is in full agreement with the reported astrophysical observations and supports the novel scenario proposed by Gu et al.

  16. Characterizations of MCP performance in the hard x-ray range (6–25 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ming, E-mail: minwu@sandia.gov; Rochau, Greg [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Moy, Ken [Special Technology Laboratories, NSTec, Santa Barbara, California 93111-2335 (United States); Kruschwitz, Craig [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    MCP detector performance at hard x-ray energies from 6 to 25 keV was recently investigated using NSLS beamline X15A at BNL. Measurements were made with an NSTec Gen-II (H-CA-65) framing camera, based on a Photonis MCP with ∼10 μm in diameter pores, ∼12 μm center-center spacing, an L/D ratio of 46, and a bias angle of 8°. The MCP characterizations were focused on (1) energy and angle dependent sensitivity, (2) energy and angle dependent spatial resolution, (3) energy dependent gain performance, and (4) energy dependent dynamic range. These measurement corroborated simulation results using a Monte Carlo model that included hard x-ray interactions and the subsequent electron cascade in the MCP.

  17. An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

    International Nuclear Information System (INIS)

    Lin, Yuan; Samei, Ehsan; Ramirez-Giraldo, Juan Carlos; Gauthier, Daniel J.; Stierstorfer, Karl

    2014-01-01

    spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures

  18. Energy dispersion of x-ray continua in the energy range 9kev to 19kev refraction on Si wafers

    International Nuclear Information System (INIS)

    Ebel, H.; Streli, C.; Pepponi, G.; Wobrauschek, P.

    2000-01-01

    Total reflection of x-rays in matter at given grazing incidence angle is characterized by the occurrence of an energy cut-off. Photons with energies greater than the cut-off energy penetrate into matter and are refracted according to a transition from the optically more dense to the optically less dense medium. Since the refractive index depends on photon energy, an energy dispersion of continuous x-radiation is observed. The present investigation is dedicated to the energy dispersion of continuous x-radiation (Mo, 45 kV) by Si wafers. Theory and experimental results are in excellent agreement. (author)

  19. Experimental and theoretical determination of the absorption coefficients of X-rays through barium plaster from 100 to 400 keV

    International Nuclear Information System (INIS)

    Joksimovicj, V.

    1976-01-01

    The absorption coefficients of X-rays from 100 to 400 keV through barium plaster of equivalent atomic number of 26 have been determined experimentally and theoretically. Calculated values are compared with experimental data. Matrix components of barium plaster were determined chemically and by X-ray fluorescence

  20. Measurement of 2-5 keV x-ray emission from laser-target interactions by using fluor-MCP and CsI-XRD detectors

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Tirsell, K.G.; Leipelt, G.R.; Laird, W.B.

    1981-01-01

    For inertial confinement fusion plasma diagnostics, x-ray diode (XRD) detectors using conventional cathodes are not sensitive enough to measure x-rays above approx. 1.5 keV. However, for laser driver fusion targets, x-rays in the range of 2 to 5 keV are important because of their mobility in the target. We have successfully used fluor-microchannel plate (MCP) detectors to obtain absolute x-ray measurements in the 2 to 5 keV range. Recent data obtained from experiments on the Shiva laser system are presented. In addition, designs for a variety of channels in the range using fluor-MCP and CsI-XRD's above 1.5 keV will be discussed

  1. A New Observation of the Quiet Sun Soft X-ray (0.5-5 keV) Spectrum

    Science.gov (United States)

    Caspi, Amir; Woods, Thomas N.; Stone, Jordan

    2013-03-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable with solar activity. While this is particularly true during solar flares, when emission can be enhanced by many orders of magnitude up to gamma-ray energies, even the so-called "quiet Sun" is bright in soft X-rays (SXRs), as the 1-2 MK ambient plasma of the corona emits significant thermal bremsstrahlung up to 5 keV. However, the actual solar SXR (0.5-5 keV) spectrum is not well known, particularly during quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include ultra-high-resolution but very narrow-band spectra from crystral spectrometers (e.g. Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g. GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with fair energy resolution ( 0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and XRS on MESSENGER, although they did not extend below 1 keV. We present observations of the quiet Sun SXR emission obtained using a new SXR spectrometer flown on the third SDO/EVE underflight calibration rocket (NASA 36.286). The commercial off-the-shelf Amptek X123 silicon drift detector, with an 8-micron Be window and custom aperture, measured the solar SXR emission from 0.5 to >10 keV with 0.15 keV FWHM resolution (though, due to hardware limitations, with only 0.12 keV binning) and 2-sec cadence over 5 minutes on 23 June 2012. Despite the rising solar cycle, activity on 23 June 2012 was abnormally low, with no visible active regions and GOES XRS emission near 2010 levels; we measured no solar counts above 4 keV during the observation period. We compare our X123 measurements with spectra and broadband irradiances from other instruments, including the SphinX observations during the deep solar minimum of 2009, and with upper limits of >3 keV quiet Sun emission

  2. X-ray optics for 50-100 keV undulator radiation using crystals and refractive lenses

    International Nuclear Information System (INIS)

    Shastri, S. D.; Mashayekhi, A.; Cremer, J. T.; Piestrup, M. A.

    2003-01-01

    Compound refractive lenses (CRLs) are effective for collimating or focusing high-energy x-ray beams (50 - 100 keV) and can be used in conjunction with crystal optics in a variety of configurations, as demonstrated at the 1-ID undulator beamline of the Advanced Photon Source. As a primary example, this article describes the quadrupling of the output flux when a collimating CRL, composed of cylindrical holes in aluminum, is inserted in between two successive monochromators -- a modest energy resolution premonochromator followed by a high-resolution monochromator. The premonochromator is a cryogenically cooled, divergence-preserving, bent double-Laue Si(111) crystal device delivering an energy width ΔE/E ∼ 10 -3 , sufficient for most experiments. The high-resolution monochromator is a four-reflection, flat Si(111) crystal system resembling two channel-cuts in a dispersive arrangement, reducing the bandwidth to ΔE/E -4 , as required for some applications. Tests with 67 keV and 81 keV photon energies show that the high-resolution monochromator, having a narrow angular acceptance of a few erad, exhibits, a four-fold throughput enhancement due to the insertion of a CRL which reduces the premonochromatized beam's vertical divergence from 29 erad to a few erad. The ability to focus high-energy x-rays with CRLs having long focal lengths (tens of meters) is also shown by creating a line focus of 70 - 90 μ m beam height in the beamline end-station with both the modest-energy-resolution and high-energy- resolution monochromatic x-rays

  3. Microstructural characterization of porous materials by X-ray microtomography and gamma ray transmission techniques

    International Nuclear Information System (INIS)

    Moreira, Anderson Camargo

    2006-01-01

    This work presents the application of the X-ray microtomography and gamma ray transmission techniques for the microstructure characterization of different kinds of materials. Total porosity, pore size distribution and the two point correlation functions were measured. The two point correlation function, which allows the reconstruction of 3D models, was carried out for two samples. Seven ceramic tablets of Alumina (Al 2 O 3 ), seven tablets of Boron Carbide (B 4 C), three samples of sedimentary rocks and one sample of Titanium foam were analyzed. The experimental set up for the Gamma Ray Transmission technique consisted of: a 2'' x 2'' crystal NaI(Tl) detector, an 241 Am radioactive source (59,53 keV, 100 mCi), an automatic micrometric table for the sample XZ movement and standard gamma spectrometry electronics. Two microtomography systems were used: a Fein Focus system, constituted by an X-ray tube, operated at 160 kV and 0.3 to 1.1 mA, a CCD camera and the movement sample system, and a Skyscan system, model 1072, with a X-ray tube operated at 100 kV and 100μA, and a CCD camera. The ceramic tablets, analyzed by the gamma ray transmission technique presented results for most of the porosities data with smaller confidence intervals and inside the intervals supplied by the tablets manufacturer. The Titanium porous sample was analyzed by the two techniques, its microtomography images achieved a resolution of 17μm, obtained employing the Fein Focus system. For both techniques, this sample showed high porosity, which allows its application for this purpose. The sandstones samples were analyzed by the Skyscan system, achieving resolutions of 19μm, 11μm and 3.8μm for each sample, respectively. The resolutions of 11μm and 3.8μm were the ones that generated better 2D sections for the respective samples and, consequently, more reliable porosities. The 3.8μm resolution was the one that best quantified the pore size distribution data, showing information not shown by

  4. X-ray attenuation coefficients and photoelectric cross sections of Cu, Fe and Sn for the energy range 3-29 KeV

    International Nuclear Information System (INIS)

    Wang Dachun; Yang Hua; Luo Pingan; Ding Xunliang; Wang Xinfu; Zhou Hongyu; Shen Xinyin; Zhu Guanghua

    1991-08-01

    The document contains the following two papers: X-ray attenuation coefficient and photoelectric cross sections of Sn for the Energy Range 3.3 KeV to 29.1 KeV - by Wang Dachun, Yang Hua and Luo Pingan. X-ray attenuation coefficients and photoelectric cross sections of Cu and Fe for the range 3 KeV to 29 KeV - by Wang Dachun, Ding Xunliang, Wang Xinfu, Yang Hua, Zhou Hongyu, Shen Xinyin and Zhu Guanghua. A separate abstract was prepared for each of these papers. Refs, figs and tabs

  5. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-01-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. The authors built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses their calibration philosophy and techniques, and describes some of the x-ray sources. Examples of actual calibration data are presented as well

  6. Facilities and Techniques for X-Ray Diagnostic Calibration in the 100-eV to 100-keV Energy Range

    Science.gov (United States)

    Gaines, J. L.; Wittmayer, F. J.

    1986-08-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well.

  7. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-06-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well

  8. Intensity-dependent resonant transmission of x-rays in solid-density aluminum plasma

    Science.gov (United States)

    Cho, M. S.; Chung, H.-K.; Cho, B. I.

    2018-05-01

    X-ray free-electron lasers (XFELs) provide unique opportunities to generate and investigate dense plasmas. The absorption and transmission properties of x-ray photons in dense plasmas are important in characterizing the state of the plasmas. Experimental evidence shows that the transmission of x-ray photons through dense plasmas depends greatly on the incident XFEL intensity. Here, we present a detailed analysis of intensity-dependent x-ray transmission in solid-density aluminum using collisional-radiative population kinetics calculations. Reverse saturable absorption (RSA), i.e., an increase in x-ray absorption with intensity has been observed for photon energies below the K-absorption edge and in the intensity range of 1016-1017 W/cm2 for XFEL photons with 1487 eV. At higher intensities, a transition from RSA to saturable absorption (SA) is predicted; thus, the x-ray absorption decreases with intensity above a threshold value. For XFEL photon energies of 1501 eV and 1515 eV, the transition from RSA to SA occurs at XFEL intensities between 1017-1018 W/cm2. Electron temperatures are predicted to be in the range of 30-50 eV for the given experimental conditions. Detailed population kinetics of the charge states explains the intensity-dependent absorption of x-ray photons and the fast modulation of XFEL pulses for both RSA and SA.

  9. The one square meter hard X-ray (15-200 KeV) sky survey

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; La Padula, C.D.; Polcaro, V.F.

    1981-01-01

    A long term program was started at I.A.S. since 1979 to perform a survey of the hard X-ray sky using multiwire high pressure Xenon filled Spectroscopic Proportional Counters (SPC). The first payload consisting of two very large area SPC (2,700 cm 2 each) was flown during summer 1980 from the Milo Base (Sicily, Italy). The instrument duplicated to reach 10,800 cm 2 geometric area is expected to fly from northern (1981), southern (1982) and equatorial (1983) bases to perform a deep sky survey

  10. Effect of particle size, filler loadings and x-ray tube voltage on the transmitted x-ray transmission in tungsten oxide—epoxy composites

    International Nuclear Information System (INIS)

    Noor Azman, N.Z.; Siddiqui, S.A.; Hart, R.; Low, I.M.

    2013-01-01

    The effect of particle size, filler loadings and x-ray tube voltage on the x-ray transmission in WO 3 -epoxy composites has been investigated using the mammography unit and a general radiography unit. Results indicate that nano-sized WO 3 has a better ability to attenuate the x-ray beam generated by lower tube voltages (25–35 kV) when compared to micro-sized WO 3 of the same filler loading. However, the effect of particle size on x-ray transmission was negligible at the higher x-ray tube voltages (40–120 kV). - Highlights: ► Investigated the effect of particle size of WO 3 on the x-ray attenuation ability. ► Nano-sized WO 3 has a better ability to attenuate lower x-ray energies (22–49 kV p ). ► Particle size has negligible effect at the higher x-ray energy range (40–120 kV p ).

  11. X-Ray Lines from Dark Matter Annihilation at the keV Scale.

    Science.gov (United States)

    Brdar, Vedran; Kopp, Joachim; Liu, Jia; Wang, Xiao-Ping

    2018-02-09

    In 2014, several groups reported hints for a yet unidentified line in astrophysical x-ray signals from galaxies and galaxy clusters at an energy of 3.5 keV. While it is not unlikely that this line is simply a reflection of imperfectly modeled atomic transitions, it has renewed the community's interest in models of keV-scale dark matter, whose decay would lead to such a line. The alternative possibility of dark matter annihilation into monochromatic photons is far less explored, a lapse that we strive to amend in this Letter. More precisely, we introduce a novel model of fermionic dark matter χ with O(keV) mass, annihilating to a scalar state ϕ which in turn decays to photons, for instance via loops of heavy vectorlike fermions. The resulting photon spectrum is box shaped, but if χ and ϕ are nearly degenerate in mass, it can also resemble a narrow line. We discuss dark matter production via two different mechanisms-misalignment and freeze-in-which both turn out to be viable in vast regions of parameter space. We constrain the model using astrophysical x-ray data, and we demonstrate that, thanks to the velocity dependence of the annihilation cross section, it has the potential to reconcile the various observations of the 3.5 keV line. We finally argue that the model can easily avoid structure formation constraints on keV-scale dark matter.

  12. Structural characterization of titanium porous foams by gamma rays transmission and X ray microtomography

    International Nuclear Information System (INIS)

    Moreira, Anderson C.; Appoloni, Carlos R.

    2007-01-01

    The advance in porous media studies and the consequent progresses of their applications in medicine, petroleum industry, metallurgy and others, rises the prominence of the area among scientists. This fact increases the research on different characterization techniques of porous materials. In this work three Titanium foams were analyzed by gamma rays transmission (GRT), and one of these was also analyzed by X-ray microtomography (μ-CT). The GRT experimental set consisted by a 2'' x 2''. NaI(Tl) detector, a 241-Am radioactive source (59,53 keV, 100 mCi) and a standard gamma spectrometry electronic chain. In the μ-CT technique it was used a SKYSCAN 1172 scanner consisting of an X-ray tube (20-100 kV and 0-250 μA), a CCD detector and a proper mechanic system for sample and detector movement. The system may reach ∼0.8 μm image resolution. Images of 815 slices of the sample were generated and analyzed by the IMAGO software. It permitted the determination of geometrical parameters like pore size distribution, total porosity and autocorrelation function. The analysis of data, obtained by both techniques, showed that porous media are homogeneous in the reached resolutions (1 mm to GRT and 5 μm to μ-CT). The average total porosities determined by GRT for each sample were φ 1 =53,47±0,36%, φ 2 =55,95±0,23% and φ 3 =56,80±0,56%, and the determined by μ-CT was φ 1 =53,47±0,36%. The porosity data of the Ti-1 sample shows good agreement from both techniques. The pore size distribution, from μ-CT technique of the Ti-1 sample, showed that 57% of porous phase have porous with radius in 20 to 80 μm range. (author)

  13. Compact scanning transmission x-ray microscope at the photon factory

    International Nuclear Information System (INIS)

    Takeichi, Yasuo; Inami, Nobuhito; Ono, Kanta; Suga, Hiroki; Takahashi, Yoshio

    2016-01-01

    We report the design and performance of a compact scanning transmission X-ray microscope developed at the Photon Factory. Piezo-driven linear stages are used as coarse stages of the microscope to realize excellent compactness, mobility, and vibrational and thermal stability. An X-ray beam with an intensity of ∼10 7 photons/s was focused to a diameter of ∼40 nm at the sample. At the soft X-ray undulator beamline used with the microscope, a wide range of photon energies (250–1600 eV) is available. The microscope has been used to research energy materials and in environmental sciences

  14. 8 to 11 keV x-ray sources for imaging and absorption experiments

    International Nuclear Information System (INIS)

    Molitoris, J.D.; Phillion, D.W.; Osterheld, A.L.; Stewart, R.E.; Rothman, S.D.

    1992-01-01

    We have measured the 8 to 11 keV emission spectra from plasmas produced by impinging 0.53 μm 100 and 200 ps FWHM Gaussian laser pulses on targets of different materials. The experimental spectra from W and Zn are identified by comparison with local thermodynamic equilibrium plasma emission calculations

  15. Azimuthal and polar angle dependence of L X-ray differential cross-sections of Yb at 59.54 keV photon energy

    Energy Technology Data Exchange (ETDEWEB)

    Akkuş, T.; Şahin, Y.; Yılmaz, D., E-mail: ddemir@atauni.edu.tr

    2016-01-01

    Highlights: • The azimuthal and polar angle dependence of L X-ray for Yb is investigated. • The azimuthal angle dependence of Ll and Lα X-rays are observed. • The azimuthal anisotropy of Lβ and Lγ X-rays are not observed. • The polar anisotropy of Ll and Lα X-rays are observed. • The polar anisotropy of Lβ and Lγ X-rays are not observed. - Abstract: The azimuthal and polar angle dependence of L X-ray was investigated in the same experimental setup to remove the existing ambiguity about alignments measurements. We measured Ll, Lα, Lβ and Lγ X-ray differential cross sections of Yb for several different azimuthal angles (30°, 20°, 10°, 0°, −10° and −20°) and polar angles (90°, 100°, 110°, 120°, 130° and 140°) at 59.54 keV photon energy by using a Si(Li) detector. The azimuthal angle dependence of Ll and Lα X-rays were observed. The azimuthal anisotropy of Lβ and Lγ X-rays were not observed. On the other hand, differential cross-sections for Lβ and Lγ X-rays were found independent on the polar angle within experimental error, those for Ll and Lα X-rays depended on the polar angles. Azimuthal and polar angles dependence of L X-ray differential cross-sections contrast with the other experimental and theoretical results, which report evidence of the isotropic emission of Ll and Lα X-rays following photoionization.

  16. Double and single ionization of helium by 58-keV X-rays

    International Nuclear Information System (INIS)

    Spielberger, L.; Buslaps, T.; Braeuning, H.; Gemmell, D.S.; Schmidt-Boecking, H.

    1996-03-01

    We have measured the ratio of cross sections for double to single ionization of helium by Compton scattering, R c =σ c ++ /σ c + at a photon energy of 58 keV using Cold Target Recoil Ion Momentum Spectroscopy. We find a value R c =(0.84 -11 +08 )% that is in agreement with the asymptotic limits predicted by Andersson and Burgdoerfer (Phys. Rev. A 50, R2810 (1994)) and Suric et al. (Phys. Rev. Lett. 73, 790 (1994)). (orig.)

  17. Note: On the generation of sub-300 keV flash-X-rays using rod-pinch diode: An experimental investigation

    Energy Technology Data Exchange (ETDEWEB)

    Satyanarayana, N.; Rajawat, R. K.; Basu, Shibaji [Facility for Electromagnetic Systems, BARCF(V), B-Block, Autonagar, Visakhapatnam 530012, Andhra Pradesh (India); Rao, A. Durga Prasad [Department of Nuclear Physics, Andhra University, Visakhapatnam 530001, Andhra Pradesh (India); Mittal, K. C. [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, Maharashtra (India)

    2014-09-15

    Generation of flash X-rays (FXRs) at less than 500 keV is described with emphasis on experimental investigation. The pulser is a Tesla transformer-Water transmission line based pulsed power generator operating in double resonance mode to power a rod-pinch diode. The configuration of aspect ratio reported here falls much below the normally reported ratios for the rod-pinch diode operation. Experimental investigation at such low pulsed voltage has revealed “flowering” of the anode tip and “pitting” of the perspex window. A possible explanation in terms of Lorentz body force is discussed rather than the pinch mechanism generally suggested in literature. The experimental investigation for the FXR generation is corroborated by measuring the radiation dose using CaSO{sub 4} (Dy) thermo luminescent dosimeters.

  18. The X-ray structure of Centaurus A from 0.1 to 50 keV observations with Exosat

    International Nuclear Information System (INIS)

    Morini, M.; Anselmo, F.; Molteni, D.

    1989-01-01

    The results from four Exosat observations of the radio galaxy Centaurus A performed during 1984-1985 are presented. The emission from the nucleus detected in the medium-energy X-ray band exhibits time variability on all time scales from a few minutes to years. Small changes are detected in the spectra of the source obtained at the different epochs. All spectra are well fitted by a power law with energy index alpha = 0.70 and strong low-energy photoelectric absorption, with an absorbing column N(H) variable between 1.4 and 1.7 x 10 to the 23rd/sq cm. An unabsorbed component is observed at low energies in all spectra which can be fitted with a thermal spectrum with T roughly 1.6 keV and which is consistent with the integrated emission of the spatially extended sources outside the nucleus. An iron fluorescence line is detected at 6.4 keV which seems to be constant in absolute intensity. The iron K-absorption edge at 7.1 keV is also observed, and the abundance of absorbing iron relative to lighter elements is larger than the cosmic value. 43 refs

  19. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zeniya, T.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T

    2001-07-21

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  20. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Science.gov (United States)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  1. X-ray intensity fluctuation spectroscopy in the energy range from 1 to 4 keV

    Energy Technology Data Exchange (ETDEWEB)

    Retsch, C.C.

    2001-06-01

    X-ray intensity fluctuation spectroscopy was developed in the energy range of 1 to 4 keV and was used to study complex sample structures and dynamics in a liquid-crystal - aerosil dispersion. The advantages of a focusing versus a nonfocusing setup were explored, and the effects of using X-ray energies near absorption edges were investigated to enhance the capabilities of the method. It was found that even though excellent real space resolution and an increase in flux density can be gained from a Fresnel zone plate focusing setup, this usually comes at the expense of speckle contrast. At absorption edges, the speckle contrast is dominated by the imaginary part of the sample's index of refraction and therefore varies in a way similar to the total transmitted intensity. Employing these results, the dynamics of a dispersion of low-density silica aerosil in octylcyanobiphenyl (8CB) were studied. It was found that the known cross-over behavior of 8CB - aerosil samples towards the 3d-XY universality class should be understood as the coupling of the aerosil-gel dynamics to the dynamics of the director fluctuations in the liquid-crystal. This work indicates that the aerosil-gel mimics and dampens these director fluctuations and thus, by suppressing the director fluctuations, achieves a pure 3d-XY system. (orig.)

  2. Using X-ray transmission/attenuation to quantify fluid absorption in cracked concrete

    DEFF Research Database (Denmark)

    Weiss, Jason; Geiker, Mette R.; Hansen, Kurt Kielsgaard

    2015-01-01

    Cracks can alter the rate of fluid transport in concrete. Unfortunately, however, quantitative information is lacking to provide definitive statements regarding the extent to which cracks reduce durability or long-term performance. This paper describes a study that used X-ray transmission......-ray attenuation measurements were taken using a grid of points around the crack. By repeating this measurement and comparing the change in X-ray transmission/attenuation, the ingress of the fluid could be determined by locating the position of the moisture front. An approach is presented to determine the geometry...

  3. The Z accelerator as a source of > 100 kJ of x-rays above 4.8 keV

    International Nuclear Information System (INIS)

    Deeney, C.; Coverdale, C.A.; Spielman, R.B.

    1998-01-01

    Recent K-shell scaling experiments on the 20 MA Z accelerator at Sandia National Laboratories have shown that large diameter (40 and 55 mm) arrays can be imploded with 80 to 210 wires of titanium or stainless steel. These implosions have produced up to 150 kJ of > 4.5 keV x-rays and 65 kJ of > 6.0 keV x-rays in 7 to 18 ns FWHM pulses. This is a major advance in plasma radiation source (PRS) capability since there is presently limited test capability above 3 keV. In fact, Z produces more > 4.5 keV x-rays than previous aboveground simulators produced at 1.5 keV. Z also produces some 200 kJ of x-rays between 1 and 3 keV in a continuous spectrum for these loads. The measured spectra and yields are consistent with 1-dimensional MHD calculations performed by NRL. Thermoelastic calorimeters, PVDF gauges, and optical impulse gauges have been successfully fielded with these sources

  4. Measurements of L shell X-ray yields of thick Ag target by 6–29 keV electron impact

    International Nuclear Information System (INIS)

    Zhao, J.L.; Tian, L.X.; Li, X.L.; An, Z.; Zhu, J.J.; Liu, M.T.

    2015-01-01

    In this paper, the L shell X-ray yields for a thick Ag target have been measured at incident electron energies of 6–29 keV. The experimental values are compared with the Monte Carlo simulation results that are obtained by using the PENELOPE code, in which the inner-shell ionization cross sections by electron impact calculated in the theoretical frame of distorted wave Born approximation are used. The experimental and simulation values are in agreement with ∼10% difference. Meanwhile, the L shell X-ray production cross sections are also obtained based on the measured L shell X-ray yields for a thick Ag target in this paper, and are compared with other experimental Ag L shell X-ray production cross section data by electron and positron impact measured previously and some theoretical models. Some factors that could affect these comparisons are also discussed in this paper. - Highlights: • We measured L shell X-ray yields of thick Ag target by 6–29 keV electrons. • Our measured X-ray yields are in good agreement with the MC results with ∼10%. • L shell production cross sections are obtained based on the measured X-ray yields. • L shell production cross sections obtained are in good agreement with theories

  5. Soft x-ray transmission measurements on thin films used for XMM CCD-filters

    Science.gov (United States)

    Stephan, K.-H.; Reppin, C.; Maier, H. J.; Frischke, D.; Fuchs, D.; Müller, P.

    1997-02-01

    We have been developing optical filters for ESA's X-ray astronomy project XMM (X-ray Multi Mirror Mission). Specific CCDs will be used as detectors in the focal plane on board the observatory (1). Since these detectors are sensitive from the X-ray to the near infrared spectral range, X-ray observations require optical filters, which combine a high transparency for photon energies in the soft X-ray region and a high opacity for ultraviolet and visible radiation as well. With respect to the mission goal in orbit three types of flight model filters are designed having different spectral transmittance functions. We report on one of these types, a so-called "thick" filter, which has been realized within the EQM (Electrical Qualification Model)-phase of the project. The filter features a cut-off in the extreme ultraviolet spectral range and suppresses radiation below ˜10 eV photon energy by more than 8 orders of magnitude. It has an effective aperture of 73 mm without any support structure. A 0.35 μm thick polypropylene carrier foil is coated with metallic films of Al and Sn. We describe transmission measurements in the soft X-ray photon energy range to determine the thickness of the individual layers and present the optical performance data of the filter.

  6. L X-ray fluorescence cross sections experimentally determined for elements with 45keV

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, Edgardo V., E-mail: bonzie@famaf.unc.edu.ar [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Badiger, Nagappa M. [Departments of Physics, Karnatak University, Dharwad 580 003, Karnataka (India); Grad, Gabriela B. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Barrea, Raul A. [The Biophysics Collaborative Access Team (BioCAT), Dept of Biological Chemical, and Physical Sciences, Illinois Institute of Technology, Chicago, IL 60616 (United States); Figueroa, Rodolo G. [Departamento de Cs. Fisicas, Universidad de La Frontera, Temuco (Chile)

    2012-04-15

    Experimental determination of L fluorescence cross-sections for elements with 45keV using Synchrotron radiation. This work is part of an investigation we did at low energies in the same group of elements. The individual L X-ray photons, Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} produced in the target were measured using a Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross sections obtained in this work were compared with data calculated using coefficients from , , and Scofield and Puri et al. (1993, 1995) - Highlights: Black-Right-Pointing-Pointer Experimental data of L fluorescence cross-sections with 45keV by Synchrotron radiation. Black-Right-Pointing-Pointer The cross sections Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} obtained, were compared with calculated data. Black-Right-Pointing-Pointer The Hypermet function was used to fit the data, because it considers a tail on the left side of the peak. Black-Right-Pointing-Pointer The tail is relevant when a small peak has another one on the right side with a big area.

  7. Anatomy-based transmission factors for technique optimization in portable chest x-ray

    Science.gov (United States)

    Liptak, Christopher L.; Tovey, Deborah; Segars, William P.; Dong, Frank D.; Li, Xiang

    2015-03-01

    Portable x-ray examinations often account for a large percentage of all radiographic examinations. Currently, portable examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the x-ray spectrum, detector positioning, collimation, and source-to-detector distance. Simulations were performed using 18 computational patient models from the extended cardiac-torso (XCAT) family (9 males, 9 females; age range: 2-58 years; weight range: 12-117 kg). The ratio of air kerma at the detector with and without a patient model was calculated as the transmission factor. Our study showed that the transmission factor decreased exponentially with increasing patient thickness. For the range of patient thicknesses examined (12-28 cm), the transmission factor ranged from approximately 21% to 1.9% when the air kerma used in the calculation represented an average over the entire imaging field of view. The transmission factor ranged from approximately 21% to 3.6% when the air kerma used in the calculation represented the average signals from two discrete AEC cells behind the lung fields. These exponential relationships may be used to optimize imaging techniques for patients of various body thicknesses to aid in the design of clinical technique charts.

  8. Visualization of magnetic dipolar interaction based on scanning transmission X-ray microscopy

    International Nuclear Information System (INIS)

    Ohtori, Hiroyuki; Iwano, Kaoru; Takeichi, Yasuo; Ono, Kanta; Mitsumata, Chiharu; Yano, Masao; Kato, Akira; Miyamoto, Noritaka; Shoji, Tetsuya; Manabe, Akira

    2014-01-01

    Using scanning transmission X-ray microscopy (STXM), in this report we visualized the magnetic dipolar interactions in nanocrystalline Nd-Fe-B magnets and imaged their magnetization distributions at various applied fields. We calculated the magnetic dipolar interaction by analyzing the interaction between the magnetization at each point and those at the other points on the STXM image.

  9. Simbol-X Mirror Module Thermal Shields: I-Design and X-Ray Transmission

    Science.gov (United States)

    Collura, A.; Barbera, M.; Varisco, S.; Basso, S.; Pareschi, G.; Tagliaferri, G.; Ayers, T.

    2009-05-01

    The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

  10. Simbol-X Mirror Module Thermal Shields: I - Design and X-Ray Transmission

    International Nuclear Information System (INIS)

    Collura, A.; Varisco, S.; Barbera, M.; Basso, S.; Pareschi, G.; Tagliaferri, G.; Ayers, T.

    2009-01-01

    The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

  11. Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography

    International Nuclear Information System (INIS)

    Rocha, Wilson Roberto Dejato da

    2005-01-01

    In this work, the gamma rays transmission and X-rays microtomography techniques are used for the evaluation of the porosity and the pore size distribution of SiC ceramic foams. It was also accomplished the three-dimensional images after the determination of samples geometric parameters. The geometric parameters were obtained by two-dimensional images analyses, generated by a Microfocus system, with a CCD camera, an images intensifier, a X-rays tube and an automatic system for rotation of the sample. The spatial resolution of the images was about 32 μm. In the gamma rays transmission methodology, a Nal(Tl) scintillation detector, an 241 Am (59.53 keV, 100 mCi) radioactive source and an automatic X-Z micrometric table was used. The analyzed samples had pores density of 30, 45, 60, 80 and 100 ppi (pores per inch). The gamma rays transmission technique was accurate to supply the porosity of the samples, which ranged about 90% and was in agreement with the values supplied by manufacturer of the foams. The 30 and 45 ppi samples analyzed by X-rays microtomography showed porosity results that agree with the average porosity supplied by the manufacturer. In other hand, the 60, 80 and 100 ppi samples systematically showed average porosity about 4%, lower than the average of the manufacturer. The pore size distributions found through the software IMAGO show the presence of smaller pores than those nominated by the manufacturer. The 30 ppi samples had voids inside the solid material of the ceramic foams structure. Gaussian truncated method, used in the three-dimensional reconstruction, was not able to take into the account the voids inside the solid matrix. (author)

  12. Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

    Energy Technology Data Exchange (ETDEWEB)

    Moffet, Ryan C.; Tivanski, Alexei V.; Gilles, Mary K.

    2011-01-20

    Scanning transmission x-ray microscopy (STXM) combines x-ray microscopy and near edge x-ray absorption fine structure spectroscopy (NEXAFS). This combination provides spatially resolved bonding and oxidation state information. While there are reviews relevant to STXM/NEXAFS applications in other environmental fields (and magnetic materials) this chapter focuses on atmospheric aerosols. It provides an introduction to this technique in a manner approachable to non-experts. It begins with relevant background information on synchrotron radiation sources and a description of NEXAFS spectroscopy. The bulk of the chapter provides a survey of STXM/NEXAFS aerosol studies and is organized according to the type of aerosol investigated. The purpose is to illustrate the current range and recent growth of scientific investigations employing STXM-NEXAFS to probe atmospheric aerosol morphology, surface coatings, mixing states, and atmospheric processing.

  13. 3D elemental sensitive imaging using transmission X-ray microscopy.

    Science.gov (United States)

    Liu, Yijin; Meirer, Florian; Wang, Junyue; Requena, Guillermo; Williams, Phillip; Nelson, Johanna; Mehta, Apurva; Andrews, Joy C; Pianetta, Piero

    2012-09-01

    Determination of the heterogeneous distribution of metals in alloy/battery/catalyst and biological materials is critical to fully characterize and/or evaluate the functionality of the materials. Using synchrotron-based transmission x-ray microscopy (TXM), it is now feasible to perform nanoscale-resolution imaging over a wide X-ray energy range covering the absorption edges of many elements; combining elemental sensitive imaging with determination of sample morphology. We present an efficient and reliable methodology to perform 3D elemental sensitive imaging with excellent sample penetration (tens of microns) using hard X-ray TXM. A sample of an Al-Si piston alloy is used to demonstrate the capability of the proposed method.

  14. High-energy (>70 keV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    Science.gov (United States)

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; Martinez, D. A.; Di Nicola, P.; Tommasini, R.; Landen, O. L.; Alessi, D.; Bowers, M.; Browning, D.; Brunton, G.; Budge, T.; Crane, J.; Di Nicola, J.-M.; Döppner, T.; Dixit, S.; Erbert, G.; Fishler, B.; Halpin, J.; Hamamoto, M.; Heebner, J.; Hernandez, V. J.; Hohenberger, M.; Homoelle, D.; Honig, J.; Hsing, W.; Izumi, N.; Khan, S.; LaFortune, K.; Lawson, J.; Nagel, S. R.; Negres, R. A.; Novikova, L.; Orth, C.; Pelz, L.; Prantil, M.; Rushford, M.; Shaw, M.; Sherlock, M.; Sigurdsson, R.; Wegner, P.; Widmayer, C.; Williams, G. J.; Williams, W.; Whitman, P.; Yang, S.

    2017-03-01

    The Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20-30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4-9 × 10-4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

  15. 1- to 10-keV x-ray backlighting of annular wire arrays on the Sandia Z-machine using bent-crystal imaging techniques

    International Nuclear Information System (INIS)

    Rambo, Patrick K.; Wenger, David Franklin; Bennett, Guy R.; Sinars, Daniel Brian; Smith, Ian Craig; Porter, John Larry Jr.; Cuneo, Michael Edward; Rovang, Dean Curtis; Anderson, Jessica E.

    2003-01-01

    Annular wire array implosions on the Sandia Z-machine can produce >200 TW and 1-2 MJ of soft x rays in the 0.1-10 keV range. The x-ray flux and debris in this environment present significant challenges for radiographic diagnostics. X-ray backlighting diagnostics at 1865 and 6181 eV using spherically-bent crystals have been fielded on the Z-machine, each with a ∼0.6 eVspectral bandpass, 10 (micro)m spatial resolution, and a 4 mm by 20mm field of view. The Z-Beamlet laser, a 2-TW, 2-kJ Nd:glass laser(λ = 527 nm), is used to produce 0.1-1 J x-ray sources for radiography. The design, calibration, and performance of these diagnostics is presented.

  16. Differential and total M-shell X-ray production cross-sections of some selected elements between Au and U at 5.96 keV

    International Nuclear Information System (INIS)

    Ozdemir, Yueksel

    2007-01-01

    Differential M-shell X-ray production (MXRP) cross-sections for selected heavy elements between Au and U have been measured at 5.59 keV incident photon energy, respectively at seven angles varying from 120 o to 150 o a Si(Li) detector. The differential M-shell X-ray production cross-sections have been derived, using M-shell fluorescence yields, experimental total M X-ray production cross-sections and theoretical M-shell photoionization cross-sections. The differential M-shell X-ray production cross-sections have been compared with the semi-empirical fits. The measured differential M X-ray production cross-sections have been found within experimental error. Differential M X-ray production cross-section can be fitted to the Σ n a n Z n (n = 2) as a function of cos θ. Total M X-ray production cross-sections have been derived using the fitted values

  17. Measurement of angular dependence of M X-ray production cross-sections in Re, Bi and U at 5.96 keV

    International Nuclear Information System (INIS)

    Apaydin, G.; Tirasoglu, E.; Sogut, O.

    2008-01-01

    The M X-ray production differential cross sections in Re, Bi and U elements have been measured at the 5.96 keV incident photon energy in an angular range 135 - 155 degrees. The measurements were performed using a Fe 55 source and a Si(Li) detector. It appears that, after photoionization of inner shells, the vacancy state has equal population of magnetic substates and the subsequent X-ray emission is isotropic. Total M X-ray production cross sections from the decay at the 5.96 keV photon energies are found to be in good agreement with the calculated theoretical results using the theoretical values of M shell photoionization cross section. (authors)

  18. A high-spatial-resolution three-dimensional detector array for 30-200 keV X-rays based on structured scintillators

    DEFF Research Database (Denmark)

    Olsen, Ulrik Lund; Schmidt, Søren; Poulsen, Henning Friis

    2008-01-01

    A three-dimensional X-ray detector for imaging 30-200 keV photons is described. It comprises a set of semi-transparent structured scintillators, where each scintillator is a regular array of waveguides in silicon, and with pores filled with CsI. The performance of the detector is described...

  19. Monitoring the mass of UF6 gas and uranium deposits in aluminium pipes using X-ray fluorescence and X-ray transmission gauges

    International Nuclear Information System (INIS)

    Packer, T.W.; Smith, S.M.

    1984-12-01

    In order to determine the enrichment of UF 6 gas in centrifuge plant pipework it is necessary to measure the mass of the gas (pressure) and the mass per unit area of any uranium deposited on the pipe. This paper shows that it is possible to determine the pressure of the UF 6 gas in pipes 120 mm in diameter using an energy-dispersive X-ray fluorescence spectrometer. Results are also given of transmission measurements made using a low power X-ray generator operated at two different applied voltages. A method of using the two measurements to determine the mass per unit area of deposited uranium is described. (author)

  20. Single x-ray transmission system for bone mineral density determination

    International Nuclear Information System (INIS)

    Jimenez-Mendoza, Daniel; Vargas-Vazquez, Damian; Espinosa-Arbelaez, Diego G.; Giraldo-Betancur, Astrid L.; Hernandez-Urbiola, Margarita I.; Rodriguez-Garcia, Mario E.

    2011-01-01

    Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm 2 )], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

  1. Characteristics of Transmission-type Microfocus X-ray Tube based-on Carbon Nanotube Field Emitter

    International Nuclear Information System (INIS)

    Heo, Sung Hwan; Ihsan, Aamir; Cho, Sung Oh

    2007-01-01

    A high resolution microfocus x-ray source is widely applied to noninvasive detection for industrial demands, material science and engineering, and to diagnostic study of microbiology and micro-tomography. Carbon nanotube (CNT) is regarded as an excellent electron emitter, which outperforms conventional electron sources in point of brightness. It has been suggested that CNT is used as an electron source of a high resolution x-ray tube according to their low threshold field with atomically sharp geometry, chemically robust structure, and electric conductivity. Several researchers have reported miniaturized x-ray tube based on diode structure and micro x-ray radiography and computed tomography systems using triode types with precise emission control and electrostatic focusing. Especially, a microfocus x-ray source of 30 μm resolution has been demonstrated recently using an elliptical CNT cathode and asymmetrical Eingel lens. However, to increase the spatial resolution of x-ray source, a smaller CNT emitter is desired. Electron focusing optics must be corrected to reduce aberrations. A thin wire tip end can provide a micro-area of CNT substrate, and a magnetic lens and transmission x-ray target are proper to reduce the lens aberration and a focal length. Until now, CNT based microfocus x-ray source with less than 10 um resolution has not been shown. Here we report a microfocus x-ray source with 4.7 μm x-ray focal spot consisted of a conical CNT tip, a single solenoid lens, and a transmission type x-ray target. A magnified x-ray image larger than 230 times was resolved with advantage of microfocused focal spot and transmission x-ray target

  2. Scanning transmission x-ray microscope for materials science spectromicroscopy at the ALS

    Energy Technology Data Exchange (ETDEWEB)

    Warwick, T.; Seal, S.; Shin, H. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    The brightness of the Advanced Light Source will be exploited by several new instruments for materials science spectromicroscopy over the next year or so. The first of these to become operational is a scanning transmission x-ray microscope with which near edge x-ray absorption spectra (NEXAFS) can be measured on spatial features of sub-micron size. Here the authors describe the instrument as it is presently implemented, its capabilities, some studies made to date and the developments to come. The Scanning Transmission X-ray Microscope makes use of a zone plate lens to produce a small x-ray spot with which to perform absorption spectroscopy through thin samples. The x-ray beam from ALS undulator beamline 7.0 emerges into the microscope vessel through a silicon nitride vacuum window 160nm thick and 300{mu}m square. The vessel is filled with helium at atmospheric pressure. The zone plate lens is illuminated 1mm downstream from the vacuum window and forms an image in first order of a pinhole which is 3m upstream in the beamline. An order sorting aperture passes the first order converging light and blocks the unfocused zero order. The sample is at the focus a few mm downstream of the zone plate and mounted from a scanning piezo stage which rasters in x and y so that an image is formed, pixel by pixel, by an intensity detector behind the sample. Absorption spectra are measured point-by-point as the photon energy is scanned by rotating the diffraction grating in the monochromator and changing the undulator gap.

  3. 3D imaging of a rice pollen grain using transmission X-ray microscopy.

    Science.gov (United States)

    Wang, Shengxiang; Wang, Dajiang; Wu, Qiao; Gao, Kun; Wang, Zhili; Wu, Ziyu

    2015-07-01

    For the first time, the three-dimensional (3D) ultrastructure of an intact rice pollen cell has been obtained using a full-field transmission hard X-ray microscope operated in Zernike phase contrast mode. After reconstruction and segmentation from a series of projection images, complete 3D structural information of a 35 µm rice pollen grain is presented at a resolution of ∼100 nm. The reconstruction allows a clear differentiation of various subcellular structures within the rice pollen grain, including aperture, lipid body, mitochondrion, nucleus and vacuole. Furthermore, quantitative information was obtained about the distribution of cytoplasmic organelles and the volume percentage of each kind of organelle. These results demonstrate that transmission X-ray microscopy can be quite powerful for non-destructive investigation of 3D structures of whole eukaryotic cells.

  4. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

    Science.gov (United States)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; Harding, E. C.; Jennings, C. A.; Lamppa, D. C.; Loisel, G. P.; Martin, M. R.; Robertson, G. K.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Weis, M. R.; Porter, J. L.; McBride, R. D.

    2017-10-01

    Many experiments on Sandia National Laboratories' Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [ C R = r i ( 0 ) / r i ( t ) ] using the 6.151-keV backlighter system were too opaque to identify the inner radius r i of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

  5. L-shell X-ray production of molybdenum and niobium induced by 1500–3500 keV Xe26+ ions

    International Nuclear Information System (INIS)

    Guo, Yipan; Yang, Zhihu; Song, Zhangyong; Xu, Qiumei; Chen, Jing; Yang, Bian

    2013-01-01

    L-shell X-ray production cross sections are measured for molybdenum and niobium target induced by Xe 26+ ions. The incident energy range varies from 1500 to 3500 keV. The experimental results are well reproduced by the binding-energy-modified binary encounter approximation model in the united-atom limit. In addition to target L-shell X-ray spectra, we also observe a weak spectrum which corresponds to the forbidden transition 3d → 2s from the projectiles

  6. Adjustment of a goniometer for X-rays optics calibration in the spectral range 1.5-20 KeV

    International Nuclear Information System (INIS)

    Legistre, S.

    1992-10-01

    The aim of this memoir is the adjustment of a (θ, 2θ) goniometer coupled to X-rays source to calibrate mirrors (single layers like C, Ni, Au, etc... and multilayers like C/W, Si/W, etc...) in the spectral range 1.5 - 20 keV. For each kind of tested optics the adjustment of the goniometer include the procedure alignment of the different components (X-ray source, collimation slits, optics, detectors) and the first reflectivity measurements. Those measurements are compared those realized at LURE, using synchrotron radiation provided by SUPER ACO storage ring, and to a theoretical simulation

  7. Longitudinal detection of ferromagnetic resonance using x-ray transmission measurements

    International Nuclear Information System (INIS)

    Boero, G.; Rusponi, S.; Kavich, J.; Rizzini, A. Lodi; Piamonteze, C.; Nolting, F.; Tieg, C.; Thiele, J.-U.; Gambardella, P.

    2009-01-01

    We describe a setup for the x-ray detection of ferromagnetic resonance in the longitudinal geometry using element-specific transmission measurements. Thin magnetic film samples are placed in a static magnetic field collinear with the propagation direction of a polarized soft x-ray beam and driven to ferromagnetic resonance by a continuous wave microwave magnetic field perpendicular to it. The transmitted photon flux is measured both as a function of the x-ray photon energy and as a function of the applied static magnetic field. We report experiments performed on a 15 nm film of doped Permalloy (Ni 73 Fe 18 Gd 7 Co 2 ) at the L 3 /L 2 -edges of Fe, Co, and Ni. The achieved ferromagnetic resonance sensitivity is about 0.1 monolayers/√(Hz). The obtained results are interpreted in the framework of a conductivity tensor based formalism. The factors limiting the sensitivity as well as different approaches for the x-ray detection of ferromagnetic resonance are discussed.

  8. Data transmission from the DRON-2 X-ray diffractometers to a computer

    International Nuclear Information System (INIS)

    Abramov, V.G.; Monov, N.A.; Sazonov, V.F.; Chernomorskaya, E.A.

    1991-01-01

    The circuit of data transmission from DRON-2 X-ray diffractometer to a measurement-computation complex based on UVK SM-3 computer and CAMAC crate is described. The data is transmitted along two-wire TRP 1x2 telephone line of 'current loop type'. Pulses from intensity channel outlet are transmitted as unipolar mark pulses of ∼1 μs duration. The channels are separated by amplitudes

  9. Time-resolved X-ray transmission microscopy on magnetic microstructures; Zeitaufloesende Roentgentransmissionsmikroskopie an magnetischen Mikrostrukturen

    Energy Technology Data Exchange (ETDEWEB)

    Puzic, Aleksandar

    2007-10-23

    Three excitation schemes were designed for stroboscopic imaging of magnetization dynamics with time-resolved magnetic transmission X-ray microscopy (TR-MTXM). These techniques were implemented into two types of X-ray microscopes, namely the imaging transmission X-ray microscope (ITXM) and the scanning transmission X-ray microscope (STXM), both installed at the electron storage ring of the Advanced Light Source in Berkeley, USA. Circular diffraction gratings (Fresnel zone plates) used in both microscopes as focusing and imaging elements presently allow for lateral resolution down to 30 nm. Magnetic imaging is performed by using the X-ray magnetic circular dichroism (XMCD) as element specific contrast mechanism. The developed methods have been successfully applied to the experimental investigation of magnetization dynamics in ferromagnetic microstructures. A temporal resolution well below 100 ps was achieved. A conventional pump-probe technique was implemented first. The dynamic response of the magnetization excited by a broadband pulsed magnetic field was imaged spatially resolved using focused X-ray flashes. As a complementary method, the spatially resolved ferromagnetic resonance (SR-FMR) technique was developed for experimental study of magnetization dynamics in the frequency domain. As a third excitation mode, the burst excitation was implemented. The performance and efficiency of the developed methods have been demonstrated by imaging the local magnetization dynamics in laterally patterned ferromagnetic thin-film elements and three-layer stacks. The existence of multiple eigenmodes in the excitation spectra of ferromagnetic microstructures has been verified by using the pump-probe technique. Magnetostatic spin waves were selectively excited and detected with a time resolution of 50 ps using the SR-FMR technique. Thorough analysis of 20 in most cases independently prepared samples has verified that vortices which exhibit a low-amplitude switching of their core

  10. Time-resolved X-ray transmission microscopy on magnetic microstructures

    International Nuclear Information System (INIS)

    Puzic, Aleksandar

    2007-01-01

    Three excitation schemes were designed for stroboscopic imaging of magnetization dynamics with time-resolved magnetic transmission X-ray microscopy (TR-MTXM). These techniques were implemented into two types of X-ray microscopes, namely the imaging transmission X-ray microscope (ITXM) and the scanning transmission X-ray microscope (STXM), both installed at the electron storage ring of the Advanced Light Source in Berkeley, USA. Circular diffraction gratings (Fresnel zone plates) used in both microscopes as focusing and imaging elements presently allow for lateral resolution down to 30 nm. Magnetic imaging is performed by using the X-ray magnetic circular dichroism (XMCD) as element specific contrast mechanism. The developed methods have been successfully applied to the experimental investigation of magnetization dynamics in ferromagnetic microstructures. A temporal resolution well below 100 ps was achieved. A conventional pump-probe technique was implemented first. The dynamic response of the magnetization excited by a broadband pulsed magnetic field was imaged spatially resolved using focused X-ray flashes. As a complementary method, the spatially resolved ferromagnetic resonance (SR-FMR) technique was developed for experimental study of magnetization dynamics in the frequency domain. As a third excitation mode, the burst excitation was implemented. The performance and efficiency of the developed methods have been demonstrated by imaging the local magnetization dynamics in laterally patterned ferromagnetic thin-film elements and three-layer stacks. The existence of multiple eigenmodes in the excitation spectra of ferromagnetic microstructures has been verified by using the pump-probe technique. Magnetostatic spin waves were selectively excited and detected with a time resolution of 50 ps using the SR-FMR technique. Thorough analysis of 20 in most cases independently prepared samples has verified that vortices which exhibit a low-amplitude switching of their core

  11. Studies of soft x-ray transmission through grid supported CH layers

    Science.gov (United States)

    Davis, J. S.; Keiter, P. A.; Klein, S. R.; Frank, Y.; Drake, R. P.; Shvarts, D.

    2017-10-01

    Recent experiments have shown that it may be possible to use laser-heated high-Z foils to drive new radiation transport (RadTran) experiments in gas fill tubes. These tubes must be pressurized above 1atm and the x-ray source needs to be physically separated from the gas. To achieve this, a grid-supported CH seal is implemented. The grid reduces the total surface area of the gas-seal interaction region lowering the thickness requirements for the CH layer. However, as mesh spacing is reduced, hole closure from wire ablation may reduce the x-ray flux. To optimize the seal design, experiments were performed measuring x-ray transmission through CH layers supported by meshes composed of copper, gold, or stainless steel and using hexagonal or square mesh geometries. The x-ray source was formed by heating a 0.5 μm thick planar gold foil with a 4 ns laser pulse at an intensity of 2 ×1014 W / cm 2. Emission data was collected using an x-ray framing camera and a Dante photodiode array. Experiments show that the CH layers can reach effective temperatures of nearly 100 eV but mesh design significantly affects performance, with a nearly 20 eV difference between the best and worst performing seal targets. This talk will discuss our findings and their impact on future RadTran experiments. This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HED Laboratory Plasmas, Grant Number DE-NA0001840, the National LUFP, Grant Number DE-NA0000850, and through NNSA/OICF under Cooperatvie Agreement No. DE-FC52-08NA2830.

  12. Contribution to time resolved X-ray fluence and differential spectra measurement method improvement in 5-200 KeV range. Application to pulsed emission sources

    International Nuclear Information System (INIS)

    Vie, M.

    1983-09-01

    Two types of sensors have been developed to measure locally the time-resolved fluence and differential energetic spectrum of pulsed X-ray in the energy range 5 to 200 keV. Rise time of these sensors is very short (10 ns) in order to permit time-resolved measurements. Fluence sensors have been developed by putting filters in front of detector in order to make sensor response independent of X-ray energy and proportional to X-ray fluence. The energetic differential spectrum was calculated by way of a method similar to the ROSS method but using filters separated within a pair defining adjacent spectral width. A detailed analysis of uncertainties affecting calculated fluence and spectrum has been done [fr

  13. Nanoscale examination of microdamage in sheep cortical bone using synchrotron radiation transmission x-ray microscopy.

    Directory of Open Access Journals (Sweden)

    Garry R Brock

    Full Text Available Microdamage occurs in bone through repeated and excessive loading. Accumulation of microdamage weakens bone, leading to a loss of strength, stiffness and energy dissipation in the tissue. Imaging techniques used to examine microdamage have typically been limited to the microscale. In the current study microdamage was examined at the nanoscale using transmission x-ray microscopy with an x-ray negative stain, lead-uranyl acetate. Microdamage was generated in notched and unnotched beams of sheep cortical bone (2×2×20 mm, with monotonic and fatigue loading. Bulk sections were removed from beams and stained with lead-uranyl acetate to identify microdamage. Samples were sectioned to 50 microns and imaged using transmission x-ray microscopy producing projection images of microdamage with nanoscale resolution. Staining indicated microdamage occurred in both the tensile and compressive regions. A comparison between monotonic and fatigue loading indicated a statistically significant greater amount of stain present in fatigue loaded sections. Microdamage occurred in three forms: staining to existing bone structures, cross hatch damage and a single crack extending from the notch tip. Comparison to microcomputed tomography demonstrated differences in damage morphology and total damage between the microscale and nanoscale. This method has future applications for understanding the underlying mechanisms for microdamage formation as well as three-dimensional nanoscale examination of microdamage.

  14. Confocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations

    International Nuclear Information System (INIS)

    Späth, Andreas; Raabe, Jörg; Fink, Rainer H.

    2015-01-01

    A conventional STXM setup has been upgraded with a second micro zone plate and aligned to confocal geometry. Two confocal geometries (in-line and off-axis) have been evaluated and a discussion on prospects and limitations is presented. Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relatively large depth of focus of zone plates, the resolution of STXM along the optical axis so far stays unambiguously behind for thicker X-ray transparent specimens. This challenge can be addressed by the implementation of a second zone plate in the detection pathway of the beam, resulting in a confocal arrangement. Within this paper a first proof-of-principle study for a confocal STXM (cSTXM) and an elaborate alignment procedure in transmission and fluorescence geometry are presented. Based on first confocal soft X-ray micrographs of well known specimens, the advantage and limitation of cSTXM as well as further development potentials for future applications are discussed

  15. Confocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Späth, Andreas [Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany); Raabe, Jörg [Paul Scherrer Institut, 5232 Villigen (Switzerland); Fink, Rainer H., E-mail: rainer.fink@fau.de [Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany); Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany)

    2015-01-01

    A conventional STXM setup has been upgraded with a second micro zone plate and aligned to confocal geometry. Two confocal geometries (in-line and off-axis) have been evaluated and a discussion on prospects and limitations is presented. Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relatively large depth of focus of zone plates, the resolution of STXM along the optical axis so far stays unambiguously behind for thicker X-ray transparent specimens. This challenge can be addressed by the implementation of a second zone plate in the detection pathway of the beam, resulting in a confocal arrangement. Within this paper a first proof-of-principle study for a confocal STXM (cSTXM) and an elaborate alignment procedure in transmission and fluorescence geometry are presented. Based on first confocal soft X-ray micrographs of well known specimens, the advantage and limitation of cSTXM as well as further development potentials for future applications are discussed.

  16. Design parameters of transmission curved crystal spectrometer for hard X-ray diagnoses

    International Nuclear Information System (INIS)

    Qian Feng; Cao Leifeng; Zhou Weimin; Zhao Zongqing; Gu Yuqiu; Yan Yonghong; Wei Lai; Xiao Shali

    2013-01-01

    The high resolving measurement of hard X-ray spectra generated in laser-produced plasma is usually performed using a cylindrically curved crystal spectrometer. In this paper, theoretical analysis and numerical simulation are performed to investigate the dependence of the energy range and resolving power on various design parameters, including crystal bending radius, source to crystal standoff distance, source size, location of the detector, etc. The investigation provides a means to design and develop cylindrically transmission curved crystal spectrometer which is used in hard X-ray diagnostics. The results show that crystal bending radius has a great influence on energy range of spectra and resolving power, and the separation between the spectral lines increases with the distance behind the focal circle faster than the line width, resulting in increased resolving power with distance. (authors)

  17. Instrumentation for in situ flow electrochemical Scanning Transmission X-ray Microscopy (STXM)

    Science.gov (United States)

    Prabu, Vinod; Obst, Martin; Hosseinkhannazer, Hooman; Reynolds, Matthew; Rosendahl, Scott; Wang, Jian; Hitchcock, Adam P.

    2018-06-01

    We report the design and performance of a 3-electrode device for real time in situ scanning transmission X-ray microscopy studies of electrochemical processes under both static (sealed, non-flow) conditions and with a continuous flow of electrolytes. The device was made using a combination of silicon microfabrication and 3D printing technologies. The performance is illustrated by results of a study of copper deposition and stripping at a gold working electrode. X-ray absorption spectromicroscopy at the Cu 2p edge was used to follow the evolution as a function of potential and time of the spatial distributions of Cu(0) and Cu(i) species electro-deposited from an aqueous solution of copper sulphate. The results are interpreted in terms of competing mechanisms for the reduction of Cu(ii).

  18. Transmission X-ray scattering as a probe for complex liquid-surface structures

    Energy Technology Data Exchange (ETDEWEB)

    Fukuto, Masafumi; Yang, Lin; Nykypanchuk, Dmytro; Kuzmenko, Ivan

    2016-01-28

    The need for functional materials calls for increasing complexity in self-assembly systems. As a result, the ability to probe both local structure and heterogeneities, such as phase-coexistence and domain morphologies, has become increasingly important to controlling self-assembly processes, including those at liquid surfaces. The traditional X-ray scattering methods for liquid surfaces, such as specular reflectivity and grazing-incidence diffraction, are not well suited to spatially resolving lateral heterogeneities due to large illuminated footprint. A possible alternative approach is to use scanning transmission X-ray scattering to simultaneously probe local intermolecular structures and heterogeneous domain morphologies on liquid surfaces. To test the feasibility of this approach, transmission small- and wide-angle X-ray scattering (TSAXS/TWAXS) studies of Langmuir films formed on water meniscus against a vertically immersed hydrophilic Si substrate were recently carried out. First-order diffraction rings were observed in TSAXS patterns from a monolayer of hexagonally packed gold nanoparticles and in TWAXS patterns from a monolayer of fluorinated fatty acids, both as a Langmuir monolayer on water meniscus and as a Langmuir–Blodgett monolayer on the substrate. The patterns taken at multiple spots have been analyzed to extract the shape of the meniscus surface and the ordered-monolayer coverage as a function of spot position. These results, together with continual improvement in the brightness and spot size of X-ray beams available at synchrotron facilities, support the possibility of using scanning-probe TSAXS/TWAXS to characterize heterogeneous structures at liquid surfaces.

  19. Comparison of x-ray computed tomography, through-transmission ultrasound, and low-kV x-ray imaging for characterizing green-state ceramics

    International Nuclear Information System (INIS)

    Roberts, R.A.; Ellingson, W.A.; Vannier, M.W.

    1985-06-01

    Green-state MgAl 2 O 4 compact disk specimens have been studied by x-ray computed tomography (CT), through-transmission pulsed ultrasound, and low-kV x-ray imaging to compare the abilities of these nondestructive evaluation (NDE) methods to detect flaws and density variations. X-ray computed tomographic images were obtained from a 125-kV (peak) imaging system with a 512 x 512 matrix and a pixel size of 100 μm. A 3- to 10- MHz focused-beam ultrasonic transducer was used, together with special immersion techniques, to obtain topographical maps of acoustic attenuation and phase velocity; a 30 x 30 matrix was used in the ultrasonic scans. A 35-kV x-ray system with high-resolution type RR film was used to obtain conventional radiographs. Large-scale nonuniform density gradients were detected with CT and ultrasonics in supposedly uniform ceramic disks. In addition, inclusions in the green-state samples were detected by all three methods, with each method providing certain advantages. The influence of grain structure and other ceramic powder characteristics will be examined in the future. 5 refs., 9 figs

  20. Spatial coherence properties of a compact and ultrafast laser-produced plasma keV x-ray source

    International Nuclear Information System (INIS)

    Boschetto, D.; Mourou, G.; Rousse, A.; Mordovanakis, A.; Hou, Bixue; Nees, J.; Kumah, D.; Clarke, R.

    2007-01-01

    The authors use Fresnel diffraction from knife-edges to demonstrate the spatial coherence of a tabletop ultrafast x-ray source produced by laser-plasma interaction. Spatial coherence is achieved in the far field by producing micrometer-scale x-ray spot dimensions. The results show an x-ray source size of 6 μm that leads to a transversal coherence length of 20 μm at a distance of 60 cm from the source. Moreover, they show that the source size is limited by the spatial spread of the absorbed laser energy

  1. Hard x-ray (>100 keV) imager to measure hot electron preheat for indirectly driven capsule implosions on the NIF.

    Science.gov (United States)

    Döppner, T; Dewald, E L; Divol, L; Thomas, C A; Burns, S; Celliers, P M; Izumi, N; Kline, J L; LaCaille, G; McNaney, J M; Prasad, R R; Robey, H F; Glenzer, S H; Landen, O L

    2012-10-01

    We have fielded a hard x-ray (>100 keV) imager with high aspect ratio pinholes to measure the spatially resolved bremsstrahlung emission from energetic electrons slowing in a plastic ablator shell during indirectly driven implosions at the National Ignition Facility. These electrons are generated in laser plasma interactions and are a source of preheat to the deuterium-tritium fuel. First measurements show that hot electron preheat does not limit obtaining the fuel areal densities required for ignition and burn.

  2. Efficient laser-induced 6-8 keV x-ray production from iron oxide aerogel and foil-lined cavity targets

    Energy Technology Data Exchange (ETDEWEB)

    Pérez, F.; Kay, J. J.; Patterson, J. R.; Kane, J.; Villette, B.; Girard, F.; Reverdin, C.; May, M.; Emig, J.; Sorce, C.; Colvin, J.; Gammon, S.; Jaquez, J.; Satcher, J. H.; Fournier, K. B.

    2012-08-01

    The performance of new iron-based laser-driven x-ray sources has been tested at the OMEGA laser facility for production of x rays in the 6.5–8.5 keV range. Two types of targets were experimentally investigated: low-density iron oxide aerogels (density 6-16 mg/cm36-16 mg/cm3) and stainless steel foil-lined cavity targets (steel thickness 1-5 μm1-5 μm). The targets were irradiated by 40 beams of the OMEGA laser (500 J/beam, 1 ns pulse, wavelength 351 nm). All targets showed good coupling with the laser, with <5%<5% of the incident laser light backscattered by the resulting plasma in all cases (typically <2.5%<2.5%). The aerogel targets produced Te=2Te=2 to 3 keV, ne=0.12-0.2ne=0.12-0.2 critical density plasmas yielding a 40%–60% laser-to-x-ray total conversion efficiency (CE) (1.2%–3% in the Fe K-shell range). The foil cavity targets produced Te~2 keV, Te~2 keV, ne~0.15ne~0.15 critical density plasmas yielding a 60%–75% conversion efficiency (1.6%–2.2% in the Fe K-shell range). Time-resolved images illustrate that the volumetric heating of low-density aerogels allow them to emit a higher K-shell x-ray yield even though they contain fewer Fe atoms. However, their challenging fabrication process leads to a larger shot-to-shot variation than cavity targets.

  3. INTEGRAL observations of the cosmic X-ray background in the 5-100 keV range via occultation by the Earth

    DEFF Research Database (Denmark)

    Churazov, E.; Sunyaev, R.; Revnivtsev, M.

    2007-01-01

    by the Earth atmosphere and the Earth auroral emission. Results. The spectrum of the cosmic X-ray background in the energy band 5-100 keV is obtained. The shape of the spectrum is consistent with that obtained previously by the HEAO-1 observatory, while the normalization is similar to 10% higher....... This difference in normalization can ( at least partly) be traced to the different assumptions on the absolute flux from the Crab Nebulae. The increase relative to the earlier adopted value of the absolute flux of the CXB near the energy of maximum luminosity (20-50 keV) has direct implications for the energy...

  4. Scatter and transmission doses from several pediatric X-ray examinations in a nursery

    International Nuclear Information System (INIS)

    Burrage, John W.; Rampant, Peter L.; Beeson, Brendan P.

    2003-01-01

    While several studies have investigated the dose from scattered radiation from X-ray procedures in a pediatric nursery, they examined scatter from chest procedures only, or the types of examination were not specified. The aim of this study was to collect scatter and transmission data from several types of X-ray examinations. Using a ''newborn'' anthropomorphic phantom and an ion chamber, a series of scatter and transmission dose measurements were performed using typical exposure factors for chest, chest and abdomen, skull, skeletal long bone and spine procedures. The phantom was inside a crib for all exposures. The maximum scatter dose measured at 1 m from the field center was about 0.05 μGy per exposure for lateral skulls. Transmission doses for lateral exams were around 0.1 μGy per exposure at 1 m from the isocenter. The study demonstrated that scatter dose to other patients in a neonatal unit is not significant, assuming the distance between adjacent cribs is in the order of 1 m. Transmission doses are also low provided the beam is fully intercepted by the cassette. For an average workload the dose received by imaging technologists would be small. (orig.)

  5. An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Stephen T.; Nigge, Pascal; Prakash, Shruti; Gilles, Mary K. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Laskin, Alexander; Wang, Bingbing [William R. Wiley Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Leone, Stephen R. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Department of Chemistry and Department of Physics, University of California, Berkeley, California 94720 (United States)

    2013-07-15

    We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconfiguration. The reactor accommodates many gas atmospheres, but was designed specifically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor reduces x-ray absorption from the process gas by over 85% compared to analogous experiments with the entire STXM instrument filled with process gas. Reduced absorption by the process gas allows data collection at full instrumental resolution, minimizes radiation dose to the sample, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

  6. Bone histomorphometric quantification by X-ray phase contrast and transmission 3D SR microcomputed tomography

    International Nuclear Information System (INIS)

    Nogueira, L.P.; Pinheiro, C.J.G.; Braz, D.; Oliveira, L.F.; Barroso, R.C.

    2008-01-01

    Full text: Conventional histomorphometry is an important method for quantitative evaluation of bone microstructure. X-ray computed tomography is a noninvasive technique, which can be used to evaluate histomorphometric indices. In this technique, the output 3D images are used to quantify the whole sample, differently from the conventional one, in which the quantification is performed in 2D slices and extrapolated for 3D case. Looking for better resolutions and visualization of soft tissues, X-ray phase contrast imaging technique was developed. The objective of this work was to perform histomorphometric quantification of human cancellous bone using 3D synchrotron X ray computed microtomography, using two distinct techniques: transmission and phase contrast, in order to compare the results and evaluate the viability of applying the same methodology of quantification for both technique. All experiments were performed at the ELETTRA Synchrotron Light Laboratory in Trieste (Italy). MicroCT data sets were collected using the CT set-up on the SYRMEP (Synchrotron Radiation for Medical Physics) beamline. Results showed that there is a better correlation between histomorphometric parameters of both techniques when morphological filters had been used. However, using these filters, some important information given by phase contrast are lost and they shall be explored by new techniques of quantification

  7. Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

    International Nuclear Information System (INIS)

    Andrianov, Konstantin; Ewald, Johannes; Nisius, Thomas; Wilhein, Thomas; Lühl, Lars; Malzer, Wolfgang; Kanngießer, Birgit

    2016-01-01

    We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2

  8. Multispecies Biofilms Transform Selenium Oxyanions into Elemental Selenium Particles: Studies Using Combined Synchrotron X-ray Fluorescence Imaging and Scanning Transmission X-ray Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Soo In; George, Graham N.; Lawrence, John R.; Kaminskyj, Susan G. W.; Dynes, James J.; Lai, Barry; Pickering, Ingrid J.

    2016-10-04

    Selenium (Se) is an element of growing environmental concern, because low aqueous concentrations can lead to biomagnification through the aquatic food web. Biofilms, naturally occurring microbial consortia, play numerous important roles in the environment, especially in biogeochemical cycling of toxic elements in aquatic systems. The complexity of naturally forming multispecies biofilms presents challenges for characterization because conventional microscopic techniques require chemical and physical modifications of the sample. Here, multispecies biofilms biotransforming selenium oxyanions were characterized using X-ray fluorescence imaging (XFI) and scanning transmission X-ray microscopy (STXM). These complementary synchrotron techniques required minimal sample preparation and were applied correlatively to the same biofilm areas. Sub-micrometer XFI showed distributions of Se and endogenous metals, while Se K-edge X-ray absorption spectroscopy indicated the presence of elemental Se (Se0). Nanoscale carbon K-edge STXM revealed the distributions of microbial cells, extracellular polymeric substances (EPS), and lipids using the protein, saccharide, and lipid signatures, respectively, together with highly localized Se0 using the Se LIII edge. Transmission electron microscopy showed the electron-dense particle diameter to be 50–700 nm, suggesting Se0 nanoparticles. The intimate association of Se0 particles with protein and polysaccharide biofilm components has implications for the bioavailability of selenium in the environment.

  9. 3-d chemical imaging using angle-scan nanotomography in a soft X-ray scanning transmission X-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Hitchcock, A.P.; Johansson, G.A. [McMaster, BIMR, Hamilton (Canada); Mitchell, G.E. [Dow Chemical, Analytical Science, Midland, MI (United States); Keefe, M.H. [Dow Chemical, Dow Latex, Midland, MI (United States); Tyliszcak, T. [LBNL, Advanced Light Source, Berkeley, CA (United States)

    2008-08-15

    Three-dimensional chemical mapping using angle scan nanotomography in a soft X-ray scanning transmission X-ray microscope (STXM) has been used to investigate the spatial distributions of a low density polyacrylate polyelectrolyte ionomer inside submicron sized polystyrene microspheres. Acquisition of tomograms at multiple photon energies provides true, quantifiable 3-d chemical sensitivity. Both pre-O 1s and C 1s results are shown. The study reveals aspects of the 3-d distribution of the polyelectrolyte that were inferred indirectly or had not been known prior to this study. The potential and challenges for extension of the technique to studies of other polymeric and to biological systems is discussed. (orig.)

  10. Characterization of the Carancas-Puno meteorite by energy dispersive X-ray fluorescence, X-ray diffractometry and transmission Moessbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ceron Loayza, Maria L., E-mail: malucelo@hotmail.com; Bravo Cabrejos, Jorge A. [Universidad Nacional Mayor de San Marcos, Laboratorio de Analisis de Suelos, Facultad de Ciencias Fisicas (Peru)

    2011-11-15

    We report the results of the study of a meteorite that impacted an inhabited zone on 15 September 2007 in the neighborhood of the town of Carancas, Puno Region, about 1,300 km south of Lima. The analysis carried out by energy dispersive X-ray fluorescence, X-ray diffractometry and transmission Moessbauer spectroscopy (at room temperature and at 4.2 K), reveal the presence in the meteorite sample of magnetic sites assigned to taenite (Fe,Ni) and troilite (Fe,S) phases, and of two paramagnetic doublets assigned to Fe{sup 2 + }, one associated with olivine and the other to pyroxene. In accord with these results, this meteorite is classified as a type IV chondrite meteorite.

  11. Extension of self-seeding to hard X-rays >10 keV as a way to increase user access at the European XFEL

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-11-01

    We propose to use the self-seeding scheme with single crystal monochromator at the European X-ray FEL to produce monochromatic, high-power radiation at 16 keV. Based on start to end simulations we show that the FEL power of the transform-limited pulses can reach about 100 GW by exploiting tapering in the tunable-gap baseline undulator. The combination of high photon energy, high peak power, and very narrow bandwidth opens a vast new range of applications, and includes the possibility to considerably increase the user capacity and fully exploit the high repetition rate of the European XFEL. In fact, dealing with monochromatic hard X-ray radiation one may use crystals as deflectors with minimum beam loss. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed for future study and possible extension of the baseline facility. They can be repeated a number of times to forman almost complete (one meter scale) ring with an angle of 20 degrees between two neighboring lines. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezo-electric devices similar to those for X-ray phase retarders at synchrotron radiation facilities. It is then possible to distribute monochromatic hard X-rays among 10 independent instruments, thereby enabling 10 users to work in parallel. The unmatched repetition rate of the European XFEL would be therefore fully exploited. (orig.)

  12. Extension of self-seeding to hard X-rays >10 keV as a way to increase user access at the European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-11-15

    We propose to use the self-seeding scheme with single crystal monochromator at the European X-ray FEL to produce monochromatic, high-power radiation at 16 keV. Based on start to end simulations we show that the FEL power of the transform-limited pulses can reach about 100 GW by exploiting tapering in the tunable-gap baseline undulator. The combination of high photon energy, high peak power, and very narrow bandwidth opens a vast new range of applications, and includes the possibility to considerably increase the user capacity and fully exploit the high repetition rate of the European XFEL. In fact, dealing with monochromatic hard X-ray radiation one may use crystals as deflectors with minimum beam loss. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed for future study and possible extension of the baseline facility. They can be repeated a number of times to forman almost complete (one meter scale) ring with an angle of 20 degrees between two neighboring lines. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezo-electric devices similar to those for X-ray phase retarders at synchrotron radiation facilities. It is then possible to distribute monochromatic hard X-rays among 10 independent instruments, thereby enabling 10 users to work in parallel. The unmatched repetition rate of the European XFEL would be therefore fully exploited. (orig.)

  13. Relative efficiency calibration between two silicon drift detectors performed with a monochromatized X-ray generator over the 0.1-1.5 keV range

    Science.gov (United States)

    Hubert, S.; Boubault, F.

    2018-03-01

    In this article, we present the first X-ray calibration performed over the 0.1-1.5 keV spectral range by means of a soft X-ray Manson source and the monochromator SYMPAX. This monochromator, based on a classical Rowland geometry, presents the novelty to be able to board simultaneously two detectors and move them under vacuum in front of the exit slit of the monochromatizing stage. This provides the great advantage to perform radiometric measurements of the monochromatic X-ray photon flux with one reference detector while calibrating another X-ray detector. To achieve this, at least one secondary standard must be operated with SYMPAX. This paper presents thereby an efficiency transfer experiment between a secondary standard silicon drift detector (SDD), previously calibrated on BESSY II synchrotron Facility, and another one ("unknown" SDD), devoted to be used permanently with SYMPAX. The associated calibration process is described as well as corresponding results. Comparison with calibrated measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) Radiometric Laboratory shows a very good agreement between the secondary standard and the unknown SDD.

  14. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  15. A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV

    International Nuclear Information System (INIS)

    Vieira, A.A.; Linke, A.; Yoshimura, E.M.; Terini, R.A.; Herdade, S.B.

    2011-01-01

    Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 o , measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments.

  16. VOXES: a high precision X-ray spectrometer for diffused sources with HAPG crystals in the 2–20 keV range

    Science.gov (United States)

    Scordo, A.; Curceanu, C.; Miliucci, M.; Shi, H.; Sirghi, F.; Zmeskal, J.

    2018-04-01

    Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements and has been widely used in several fields, going from fundamental physics to quantum mechanics tests, synchrotron radiation and X-FEL applications, astronomy, medicine and industry. However, this technique is limited to the measurement of photons produced from well collimated or point-like sources and becomes quite inefficient for photons coming from extended and diffused sources like those, for example, emitted in the exotic atoms radiative transitions. The VOXES project's goal is to realise a prototype of a high resolution and high precision X-ray spectrometer, using Highly Annealed Pyrolitic Graphite (HAPG) crystals in the Von Hamos configuration, working also for extended sources. The aim is to deliver a cost effective system having an energy resolution at the level of eV for X-ray energies from about 2 keV up to tens of keV, able to perform sub-eV precision measurements with non point-like sources. In this paper, the working principle of VOXES, together with first results, are presented.

  17. Kaolinite flocculation induced by smectite addition - a transmission X-ray microscopic study.

    Science.gov (United States)

    Zbik, Marek S; Song, Yen-Fang; Frost, Ray L

    2010-09-01

    The influence of smectite addition on kaolinite suspensions in water was investigated by transmission X-ray microscopy (TXM) and Scanning Electron Microscopy (SEM). Sedimentation test screening was also conducted. Micrographs were processed by the STatistic IMage Analysing (STIMAN) program and structural parameters were calculated. From the results of the sedimentation tests important influences of small smectite additions to about 3wt.% on kaolinite suspension flocculation has been found. In order to determine the reason for this smectite impact on kaolinite suspension, macroscopic behaviour micro-structural examination using Transmission X-ray Microscope (TXM) and SEM has been undertaken. TXM & SEM micrographs of freeze-dried kaolinite-smectite suspensions with up to 20% smectite showed a high degree of orientation of the fabric made of highly oriented particles and greatest density when 3wt.% of smectite was added to the 10wt.% dense kaolinite suspension. In contrast, suspensions containing pure kaolinite do not show such platelet mutual orientation but homogenous network of randomly oriented kaolinite platelets. This suggests that in kaolinite-smectite suspensions, smectite forms highly oriented basic framework into which kaolinite platelets may bond in face to face preferential contacts strengthening structure and allowing them to show plastic behaviour which is cause of platelets orientation. Copyright 2010 Elsevier Inc. All rights reserved.

  18. X-ray and gamma-ray transmission computed tomographic imaging of archaeological objects

    International Nuclear Information System (INIS)

    Jaafar Abdullah; Susan Maria Sipaun

    2004-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-section images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography or computed-aided tomography. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper presents a brief overview of X-ray or gamma-ray transmission tomography. It is not intended to be a technical treatise but is hoped that it would raise awareness and promote opportunities for further collaboration amongst the nuclear research community, including archaeologists and those in the conservation profession. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. In addition, a few examples of CT images for archaeological objects are presented. The examples were purposely chosen to illustrate clearly and precisely the fundamental concepts of this sophisticated field. (Author)

  19. Application of an expectation maximization method to the reconstruction of X-ray-tube spectra from transmission data

    International Nuclear Information System (INIS)

    Endrizzi, M.; Delogu, P.; Oliva, P.

    2014-01-01

    An expectation maximization method is applied to the reconstruction of X-ray tube spectra from transmission measurements in the energy range 7–40 keV. A semiconductor single-photon counting detector, ionization chambers and a scintillator-based detector are used for the experimental measurement of the transmission. The number of iterations required to reach an approximate solution is estimated on the basis of the measurement error, according to the discrepancy principle. The effectiveness of the stopping rule is studied on simulated data and validated with experiments. The quality of the reconstruction depends on the information available on the source itself and the possibility to add this knowledge to the solution process is investigated. The method can produce good approximations provided that the amount of noise in the data can be estimated. - Highlights: • An expectation maximization method was used together with the discrepancy principle. • The discrepancy principle is a suitable criterion for stopping the iteration. • The method can be applied to a variety of detectors/experimental conditions. • The minimum information required is the amount of noise that affects the data. • Improved results are achieved by inserting more information when available

  20. X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$

    CERN Document Server

    Aune, S; Calvet, D.; Dafni, T.; Diago, A.; Druillole, F.; Fanourakis, G.; Ferrer-Ribas, E.; Galán, J.; García, J.A.; Gardikiotis, A.; Garza, J.G.; Geralis, T.; Giomataris, I.; Gómez, H.; González-Díaz, D.; Herrera, D.C.; Iguaz, F.J.; Irastorza, I.G.; Jourde, D.; Luzón, G.; Mirallas, H.; Mols, J.P.; Papaevangelou, T.; Rodríguez, A.; Seguí, L.; Tomás, A.; Vafeiadis, T.; Yildiz, S.C.

    2013-01-01

    Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detectors' response. The upgrades encompass the readout electronics, a new detector design and the implementation of a more efficient cosmic muon veto system. Background levels below 10$^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained at sea level for the first time, demonstrating the feasibility of the expectations posed by IAXO, the next generation axion helioscope. Some results obtained with a set of measurements conducted in the x-ray beam of the CAST Detector Laboratory will be also presented and discussed.

  1. Broadband transmission masks, gratings and filters for extreme ultraviolet and soft X-ray lithography

    International Nuclear Information System (INIS)

    Brose, S.; Danylyuk, S.; Juschkin, L.; Dittberner, C.; Bergmann, K.; Moers, J.; Panaitov, G.; Trellenkamp, St.; Loosen, P.; Grützmacher, D.

    2012-01-01

    Lithography and patterning on a nanometre scale with extreme ultraviolet (EUV) and soft X-ray radiation allow creation of high resolution, high density patterns independent of a substrate type. To realize the full potential of this method, especially for EUV proximity printing and interference lithography, a reliable technology for manufacturing of the transmission masks and gratings should be available. In this paper we present a development of broadband amplitude transmission masks and gratings for extreme ultraviolet and soft X-ray lithography based on free-standing niobium membranes. In comparison with a standard silicon nitride based technology the transmission masks demonstrate high contrast not only for in-band EUV (13.5 nm) radiation but also for wavelengths below Si L-absorption edge (12.4 nm). The masks and filters with free standing areas up to 1000 × 1000 μm 2 and 100 nm to 300 nm membrane thicknesses are shown. Electron beam structuring of an absorber layer with dense line and dot patterns with sub-50 nm structures is demonstrated. Diffractive and filtering properties of obtained structures are examined with EUV radiation from a gas discharge plasma source. - Highlights: ► Broadband transmission masks for EUV proximity and interference lithography. ► Technology for free standing niobium membranes with areas up to 1 mm 2 . ► High density patterns with periods of 100 nm and structure sizes below 40 nm. ► Measured diffraction efficiency at 11 nm is in agreement with the theory. ► Produced masks can be effectively used with wavelengths between 6 nm and 17 nm.

  2. Study of Radiation Shielding Properties of selected Tropical Wood Species for X-rays in the 50-150 keV Range

    Directory of Open Access Journals (Sweden)

    S. Aggrey-Smith

    2016-03-01

    Full Text Available This paper compares the attenuation coefficients of 20 tropical hard wood species based on their linear and mass attenuation and half value layer (HVL properties for X-rays of energy 50–150 keV using a narrow collimated beam from a Cs-137 source. The narrow collimated beam method made corrections from multiple and small-angle scatterings of photons unnecessary. The attenuation depended on the chemical composition and densities of the wood species. The linear attenuation coefficients of wood species at 50–150 keV were highest for Pterygota macrocarpa (4.53 m−1 and lowest for Antiaris africana (1.24 m−1; the mass attenuation coefficient was highest for Triplochiton scleroxylon (17.62 m2/kg and lowest for Nesogordonia papaverifera (2.27 m2/kg.The HVL was highest for Antiaris africana (0.27 m and lowest for Pterygota macrocarpa (0.149 m. Pterygota macrocarpa of about 0.36 m thickness could serve as a more affordable radiation shielding material against secondary scatter and leakage radiations in place of lead, copper or concrete for low X-ray radiations up to 150 keV.

  3. Advancement of Solidification Processing Technology Through Real Time X-Ray Transmission Microscopy: Sample Preparation

    Science.gov (United States)

    Stefanescu, D. M.; Curreri, P. A.

    1996-01-01

    Two types of samples were prepared for the real time X-ray transmission microscopy (XTM) characterization. In the first series directional solidification experiments were carried out to evaluate the critical velocity of engulfment of zirconia particles in the Al and Al-Ni eutectic matrix under ground (l-g) conditions. The particle distribution in the samples was recorded on video before and after the samples were directionally solidified. In the second series samples of the above two type of composites were prepared for directional solidification runs to be carried out on the Advanced Gradient Heating Facility (AGHF) aboard the space shuttle during the LMS mission in June 1996. X-ray microscopy proved to be an invaluable tool for characterizing the particle distribution in the metal matrix samples. This kind of analysis helped in determining accurately the critical velocity of engulfment of ceramic particles by the melt interface in the opaque metal matrix composites. The quality of the cast samples with respect to porosity and instrumented thermocouple sheath breakage or shift could be easily viewed and thus helped in selecting samples for the space shuttle experiments. Summarizing the merits of this technique it can be stated that this technique enabled the use of cast metal matrix composite samples since the particle location was known prior to the experiment.

  4. Measurement of angular distributions of K x-ray intensity of Ti and Cu thick targets following impact of 10–25 keV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Bhupendra; Kumar, Sunil; Prajapati, Suman; Singh, Bhartendu K. [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India); Llovet, Xavier [Scientific and Technological Centers, Universitat de Barcelona, Lluís Solé i Sabarís 1-3, 08028 Barcelona (Spain); Shanker, R., E-mail: shankerorama@gmail.com [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India)

    2017-04-15

    Highlights: • New results on the angular distributions of relative intensities of K-X-rays lines of Ti and Cu thick targets under electron bombardment are reported. • An increase of relative intensity of Kα and Kβ X-ray lines has been found to be about 60–70% in the detection range θ = 105{sup 0}–165{sup 0}. • There is a slight impact energy dependence of Cu Kα X-ray line. • A reasonable agreement between experimental and PENELOPE MC Calculations are obtained. - Abstract: We present new results on angular distributions of the relative intensity of K{sub α} and K{sub β} x-ray lines of thick targets of Ti (Z = 22) and Cu (Z = 29) pure elements following impact of 10–25 keV electrons. The angular measurements of the K x-radiations were accomplished by rotating the target surface with respect to the electron beam direction. The x-rays emerging from the target surface in reflection mode were detected by an energy dispersive Si P-I-N photodiode detector. The resulting variation of the relative intensity of the characteristic lines as a function of angle of detection and impact energy has been found to be anisotropic and it is considered to arise due to change in path lengths at a given incidence angle α for the photons generated by direct as well as by indirect K shell ionization processes. The measured angular variations of relative intensity of K{sub α} and K{sub β} x-ray lines of both targets are found to increase by about 60–70% in going from θ = 105{sup 0} to 165{sup 0} at a given impact energy; however there is a slight indication of impact energy dependence of Cu K{sub α} x-ray line as also noted by the earlier workers. We compare the experimental results with those obtained by Monte Carlo simulations using PENELOPE calculations; the agreement between experiment and theory is found to be satisfactory within uncertainties involved in the measurements and the theoretical results.

  5. YIELDS OF IONS AND EXCITED STATES IN NONPOLAR LIQUIDS EXPOSED TO X-RAYS OF 1 TO 30 KEV ENERGY

    International Nuclear Information System (INIS)

    HOLROYD, R.A.

    1999-01-01

    When x-rays from a synchrotron source are absorbed in a liquid, the x-ray energy (E x ) is converted by the photoelectric effect into the kinetic energy of the electrons released. For hydrocarbons, absorption by the K-electrons of carbon dominates. Thus the energy of the photoelectron (E pe ) is E x -E b , where E b is the K-shell binding energy of carbon. Additional electrons with energy equal to E b is released in the Auger process that fills the hole in the K-shell. These energetic electrons will produce many ionizations, excitations and products. The consequences of the high density of ionizations and excitations along the track of the photoelectron and special effects near the K-edge are examined here

  6. Monte-Carlo simulations of secondary electron emission from CsI, induced by 1-10 keV X-rays and electrons

    International Nuclear Information System (INIS)

    Akkerman, A.; Gibrekhterman, A.; Breskin, A.; Chechik, R.

    1992-05-01

    A model for electron transport and emission in CsI is proposed. It is based on theoretically calculated microscopic cross-sections for electron interaction with the nuclear and the electronic components of the solid. A Monte Carlo program based on this model was developed to simulate secondary electron emission induced by X-rays and electrons in the energy range of 1 to 10 keV. The calculated secondary emission yields agree with existing experimental data. The model provides all necessary characteristics for the design of radiation detectors based on secondary electron emission. It can be expanded to higher incident energies and other alkali halides. (author)

  7. Transmission X-ray microscopy (TXM) reveals the nanostructure of a smectite gel.

    Science.gov (United States)

    Zbik, Marek S; Martens, Wayde N; Frost, Ray L; Song, Yen-Fang; Chen, Yi-Ming; Chen, Jian-Hua

    2008-08-19

    The unusual behavior of smectites, the ability to change volume when wetted (swelling) or dried (shrinking), makes soil rich in smectites very unstable and dangerous for the building industry because of the movement of building foundations and poor slope stability. These macroscopic properties are dominated by the structural arrangement of the smectites' finest fraction. Here, we show in three dimensions how the swelling phenomenon in smectite, caused by a combination of hydratation and electrostatic forces, may expand the dry smectite volume not 10-fold, as previously thought, but to more than 1000-fold. A new technique, transmission X-ray microscopy, makes it possible to investigate the internal structure and 3-D tomographic reconstruction of clay aggregates. This reveals, for the first time, the smectite gel arrangement in the voluminous cellular tactoid structure within a natural aqueous environment.

  8. Design and performance of a compact scanning transmission X-ray microscope at the Photon Factory

    Energy Technology Data Exchange (ETDEWEB)

    Takeichi, Y., E-mail: yasuo.takeichi@kek.jp; Mase, K.; Ono, K. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Department of Materials Structure Science, SOKENDAI (The Graduate University for Advanced Studies), 1-1 Oho, Tsukuba 305-0801 (Japan); Inami, N. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Suga, H. [Department of Earth and Planetary Systems Science, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526 (Japan); Miyamoto, C. [Department of Earth and Planetary Systems Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku 113-0033 (Japan); Ueno, T. [National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Takahashi, Y. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Department of Earth and Planetary Systems Science, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526 (Japan); Department of Earth and Planetary Systems Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku 113-0033 (Japan)

    2016-01-15

    We present a new compact instrument designed for scanning transmission X-ray microscopy. It has piezo-driven linear stages, making it small and light. Optical components from the virtual source point to the detector are located on a single optical table, resulting in a portable instrument that can be operated at a general-purpose spectroscopy beamline without requiring any major reconstruction. Careful consideration has been given to solving the vibration problem common to high-resolution microscopy, so as not to affect the spatial resolution determined by the Fresnel zone plate. Results on bacteriogenic iron oxides, single particle aerosols, and rare-earth permanent magnets are presented as examples of its performance under diverse applications.

  9. Development of an X-ray imaging system within 10-30 keV spectral range based on organic or inorganic scintillator

    International Nuclear Information System (INIS)

    Turk, G.

    2011-01-01

    This thesis aims at developing an x-ray imaging system intended for the Laser Mega Joule, within the framework of Inertial Confinement Fusion (ICF) experiments. ICF aims at yielding thermonuclear energy through laser-driven fusion of a deuterium-tritium mix. The operational function of our system is to acquire an image of the 10-30 keV x-rays emitted by the maximally compressed micro-balloon, with spatial resolution better than 10 μm. The presented system is only a part of a complete diagnostic system, which normally includes an x-ray optical subsystem. Our system conception largely takes vulnerability into account. The ignition phase of ICF yields 10 16 neutrons, with energies scaling up to 14 MeV. The neutrons generate such a hard surrounding with effects scaling down from image degradation up to instrumentation destruction. The presented system consists in a scintillator which is focused on a CCD camera through a catadioptric image transport system. An innovation work has been lead on scintillators to provide an answer to specifications greatly influenced by vulnerability. Those thesis works lead to an imaging system allowing to deport the CCD camera by 4 meters from the scintillator, with 100 μm spatial resolution in the scintillator plane. Those works have paved the way to outlooks such as enhancement of organic loaded scintillators compositions and improvement of optical relay system. (author) [fr

  10. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Tovar M, V.M.; Azorin N, J.; Furetta, C.; Quiroz C, M.C.

    2005-01-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  11. Fabrication update on critical-angle transmission gratings for soft x-ray grating spectrometers

    Science.gov (United States)

    Heilmann, Ralf K.; Bruccoleri, Alex; Mukherjee, Pran; Yam, Jonathan; Schattenburg, Mark L.

    2011-09-01

    Diffraction grating-based, wavelength dispersive high-resolution soft x-ray spectroscopy of celestial sources promises to reveal crucial data for the study of the Warm-Hot Intergalactic Medium, the Interstellar Medium, warm absorption and outflows in Active Galactic Nuclei, coronal emission from stars, and other areas of interest to the astrophysics community. Our recently developed critical-angle transmission (CAT) gratings combine the advantages of the Chandra high and medium energy transmission gratings (low mass, high tolerance of misalignments and figure errors, polarization insensitivity) with those of blazed reflection gratings (high broad band diffraction efficiency, high resolution through use of higher diffraction orders) such as the ones on XMM-Newton. Extensive instrument and system configuration studies have shown that a CAT grating-based spectrometer is an outstanding instrument capable of delivering resolving power on the order of 5,000 and high effective area, even with a telescope point-spread function on the order of many arc-seconds. We have fabricated freestanding, ultra-high aspect-ratio CAT grating bars from silicon-on-insulator wafers using both wet and dry etch processes. The 200 nm-period grating bars are supported by an integrated Level 1 support mesh, and a coarser external Level 2 support mesh. The resulting grating membrane is mounted to a frame, resulting in a grating facet. Many such facets comprise a grating array that provides light-weight coverage of large-area telescope apertures. Here we present fabrication results on the integration of CAT gratings and the different high-throughput support mesh levels and on membrane-frame bonding. We also summarize recent x-ray data analysis of 3 and 6 micron deep wet-etched CAT grating prototypes.

  12. Automated correction on X-rays calibration using transmission chamber and LabVIEWTM

    International Nuclear Information System (INIS)

    Betti, Flavio; Potiens, Maria da Penha Albuquerque

    2009-01-01

    Uncertainties during prolonged exposure times on X-rays calibration procedures at the Instruments Calibration facilities at IPEN may suffer from efficiency (and therefore intensity) variations on the industrial X-Ray generator used. Using a transmission chamber as an online reference chamber during the whole irradiation process is proposed in order to compensate for such error source. Also temperature (and pressure) fluctuations may arise from the performance limited calibration room air conditioning system. As an open ionization chamber, that monitor chamber does require calculation of a correction factor due to the temperature and pressure effects on air density. Sending and processing data from all related instruments (electrometer, thermometer and barometer) can be more easily achieved by interfacing them to a host computer running an especially developed algorithm using LabVIEW TM environment which will not only apply the proper correction factors during runtime, but also determine the exact length of time to reach a desired condition, which can be: time period, charge collected, or air kerma, based on the previous calibration of the whole system using a reference chamber traceable to primary standard dosimetry laboratories. When performing such calibration, two temperature sensors (secondary standard thermistors) are simultaneously used, one for the transmission chamber, and other for the reference chamber. As the substitution method is used during actual customer's calibration, the readings from the second thermistor can also be used when desired for further corrections. Use of LabVIEW TM programming language allowed for a shorter development time, and it is also extremely convenient to make things easier when improvements and modifications are called for. (author)

  13. Image statistics and nonlinear artifacts in composed transmission x-ray tomography

    International Nuclear Information System (INIS)

    Duerinckx, A.J.G.

    1979-01-01

    Knowledge of the image quality and image statistics in Computed Tomography (CT) images obtained with transmission x-ray CT scanners can increase the amount of clinically useful information that can be retrieved. Artifacts caused by nonlinear shadows are strongly object-dependent and are visible over larger areas of the image. No simple technique exists for their complete elimination. One source of artifacts in the first order statistics is the nonlinearities in the measured shadow or projection data used to reconstruct the image. One of the leading causes is the polychromaticity of the x-ray beam used in transmission CT scanners. Ways to improve the resulting image quality and techniques to extract additional information using dual energy scanning are discussed. A unique formalism consisting of a vector representation of the material dependence of the photon-tissue interactions is generalized to allow an in depth analysis. Poly-correction algorithms are compared using this analytic approach. Both quantum and detector electronic noise decrease the quality or information content of first order statistics. Preliminary results are presented using an heuristic adaptive nonlinear noise filter system for projection data. This filter system can be improved and/or modified to remove artifacts in both first and second order image statistics. Artifacts in the second order image statistics arise from the contribution of quantum noise. This can be described with a nonlinear detection equivalent model, similar to the model used to study artifacts in first order statistics. When analyzing these artifacts in second order statistics, one can divide them into linear artifacts, which do not present any problem of interpretation, and nonlinear artifacts, referred to as noise artifacts. A study of noise artifacts is presented together with a discussion of their relative importance in diagnostic radiology

  14. Measurements of Lα, Lβ X-ray production cross sections of Bi by 17-40 keV electron impact

    International Nuclear Information System (INIS)

    Wu, Y.; An, Z.; Duan, Y.M.; Liu, M.T.

    2010-01-01

    We present results of measurements of L α , L β X-ray production cross sections for the element Bi (Z = 83) by 17-40 keV electron impact. The target used in the experiment was prepared by evaporating the element Bi to the thick pure carbon substrate. The effects of multiple scattering of electrons when penetrating the target film, of electrons reflected from the thick pure carbon substrate and of bremsstrahlung photons produced by the impact of incident electrons on the target are corrected by means of Monte Carlo simulation. The experimental data, reported here for the first time in the energy region of 17-40 keV, are compared with the DWBA theory and the PWBA-C-Ex theory. They are in good agreement.

  15. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    International Nuclear Information System (INIS)

    Donath, T; Brandstetter, S; Commichau, S; Hofer, P; Lüthi, B; Schneebeli, M; Schulze-Briese, C; Cibik, L; Krumrey, M; Marggraf, S; Müller, P; Wernecke, J

    2013-01-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm 2 ). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  16. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    Science.gov (United States)

    Donath, T.; Brandstetter, S.; Cibik, L.; Commichau, S.; Hofer, P.; Krumrey, M.; Lüthi, B.; Marggraf, S.; Müller, P.; Schneebeli, M.; Schulze-Briese, C.; Wernecke, J.

    2013-03-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm2). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  17. M sub shell X-ray emission cross section measurements for Pt, Au, Hg, Pb, Th and U at 8 and 10 keV synchrotron photons

    International Nuclear Information System (INIS)

    Kaur, Gurpreet; Gupta, Sheenu; Tiwari, M.K.; Mittal, Raj

    2014-01-01

    Highlights: • First time M sub shell fluorescence cross section measurements at 8 and 10 keV photons. • Comparison with theoretical evaluations from different model data for parameters. • Explained the large deviations from the trend of parameters with atomic number Z. • A specific pattern of cross sections with Z is predicted in the region, 78 ⩽ Z ⩽ 92. • Confirmation of prediction requires more experiment in these Z and energy region. -- Abstract: M sub shell X-ray emission cross sections of Pt, Au, Hg, Pb, Th and U at 8 and 10 keV photon energies have been determined with linearly polarized photon beam from Indus-2 synchrotron source. The measured cross sections have been reported for the first time and were used to check the available theoretical Dirac–Hartree–Slater (DHS) and Dirac–Fock (DF) values reported in literature and also the presently derived Non Relativistic Hartree–Slater (NRHS), DF and DHS values for M ξ , M δ , M α , M β , M γ , M m1 and M m2 group of X-rays

  18. Nanoscale characterization of local structures and defects in photonic crystals using synchrotron-based transmission soft X-ray microscopy

    Science.gov (United States)

    Nho, Hyun Woo; Kalegowda, Yogesh; Shin, Hyun-Joon; Yoon, Tae Hyun

    2016-01-01

    For the structural characterization of the polystyrene (PS)-based photonic crystals (PCs), fast and direct imaging capabilities of full field transmission X-ray microscopy (TXM) were demonstrated at soft X-ray energy. PS-based PCs were prepared on an O2-plasma treated Si3N4 window and their local structures and defects were investigated using this label-free TXM technique with an image acquisition speed of ~10 sec/frame and marginal radiation damage. Micro-domains of face-centered cubic (FCC (111)) and hexagonal close-packed (HCP (0001)) structures were dominantly found in PS-based PCs, while point and line defects, FCC (100), and 12-fold symmetry structures were also identified as minor components. Additionally, in situ observation capability for hydrated samples and 3D tomographic reconstruction of TXM images were also demonstrated. This soft X-ray full field TXM technique with faster image acquisition speed, in situ observation, and 3D tomography capability can be complementally used with the other X-ray microscopic techniques (i.e., scanning transmission X-ray microscopy, STXM) as well as conventional characterization methods (e.g., electron microscopic and optical/fluorescence microscopic techniques) for clearer structure identification of self-assembled PCs and better understanding of the relationship between their structures and resultant optical properties. PMID:27087141

  19. Hard-x-ray phase-imaging microscopy using the self-imaging phenomenon of a transmission grating

    International Nuclear Information System (INIS)

    Yashiro, Wataru; Harasse, Sebastien; Momose, Atsushi; Takeuchi, Akihisa; Suzuki, Yoshio

    2010-01-01

    We report on a hard-x-ray imaging microscope consisting of a lens, a sample, and a transmission grating. After the theoretical framework of self-imaging phenomenon by the grating in the system is presented, equations for the electric field on the image plane are derived for ideal and real lenses and an equation for the intensity on the image plane for partially coherent illumination is derived. The equations are simple and similar to those applying to a projection microscope consisting of a transmission grating except that there is no defocusing effect, regardless of whether the grating is in front of or behind the lens. This means that x-ray phase-imaging microscopy can be done without the defocusing effect. It is also shown that, by resolving the self-image on the image plane, high-sensitive x-ray phase-imaging microscopy can be attained without degradation in the spatial resolution due to diffraction by the grating. Experimental results obtained using partially coherent illumination from a synchrotron x-ray source confirm that hard-x-ray phase-imaging microscopy can be quantitatively performed with high sensitivity and without the spatial resolution degradation.

  20. Portable pulsed X-ray digital radiographic system based on network transmission

    International Nuclear Information System (INIS)

    Tang Le; Li Yuanjing; Wang Yi; Cheng Jianping

    2004-01-01

    Network communication technology of TCP/IP protocol serves as application in pulse X-ray digital radiography system. The system radiographs synchronously with pulse X-ray and converts image signals to digital data, which are transmitted to computer for displaying and processing in network. The system composing structures are present and portable and other characteristics are introduced. (authors)

  1. Characterization of a quadrant diamond transmission X-ray detector including a precise determination of the mean electron-hole pair creation energy.

    Science.gov (United States)

    Keister, Jeffrey W; Cibik, Levent; Schreiber, Swenja; Krumrey, Michael

    2018-03-01

    Precise monitoring of the incoming photon flux is crucial for many experiments using synchrotron radiation. For photon energies above a few keV, thin semiconductor photodiodes can be operated in transmission for this purpose. Diamond is a particularly attractive material as a result of its low absorption. The responsivity of a state-of-the art diamond quadrant transmission detector has been determined, with relative uncertainties below 1% by direct calibration against an electrical substitution radiometer. From these data and the measured transmittance, the thickness of the involved layers as well as the mean electron-hole pair creation energy were determined, the latter with an unprecedented relative uncertainty of 1%. The linearity and X-ray scattering properties of the device are also described.

  2. An analytical X-ray CdTe detector response matrix for incomplete charge collection correction for photon energies up to 300 keV

    Science.gov (United States)

    Kurková, Dana; Judas, Libor

    2018-05-01

    Gamma and X-ray energy spectra measured with semiconductor detectors suffer from various distortions, one of them being so-called "tailing" caused by an incomplete charge collection. Using the Hecht equation, a response matrix of size 321 × 321 was constructed which was used to correct the effect of incomplete charge collection. The correction matrix was constructed analytically for an arbitrary energy bin and the size of the energy bin thus defines the width of the spectral window. The correction matrix can be applied separately from other possible spectral corrections or it can be incorporated into an already existing response matrix of the detector. The correction was tested and its adjustable parameters were optimized on the line spectra of 57Co measured with a cadmium telluride (CdTe) detector in a spectral range from 0 up to 160 keV. The best results were obtained when the values of the free path of holes were spread over a range from 0.4 to 1.0 cm and weighted by a Gauss function. The model with the optimized parameter values was then used to correct the line spectra of 152Eu in a spectral range from 0 up to 530 keV. An improvement in the energy resolution at full width at half maximum from 2.40 % ± 0.28 % to 0.96 % ± 0.28 % was achieved at 344.27 keV. Spectra of "narrow spectrum series" beams, N120, N150, N200, N250 and N300, generated with tube voltages of 120 kV, 150 kV, 200 kV, 250 kV and 300 kV respectively, and measured with the CdTe detector, were corrected in the spectral range from 0 to 160 keV (N120 and N150) and from 0 to 530 keV (N200, N250, N300). All the measured spectra correspond both qualitatively and quantitatively to the available reference data after the correction. To obtain better correspondence between N150, N200, N250 and N300 spectra and the reference data, lower values of the free paths of holes (range from 0.16 to 0.65 cm) were used for X-ray spectra correction, which suggests energy dependence of the phenomenon.

  3. On generation of high power x-rays in the range 7-20 keV

    International Nuclear Information System (INIS)

    Ratakhin, N.A.

    1997-01-01

    An attempt is made on the base of general relations to evaluate possibility of two approaches to the problem of receiving powerful x-radiation id spectral range of (7-20) keV. Extremely cut possibilities of electron beams of vacuum diodes and Z-pinch plasma thermal radiation are shown. Some perspectives of increasing such radiation power in connection with possibility of generation of high-energy electrons in Z-pinch plasma are noted

  4. Measurement of the x-ray mass-attenuation coefficients of gold, derived quantities between 14 keV and 21 keV and determination of the bond lengths of gold

    International Nuclear Information System (INIS)

    Glover, J L; Chantler, C T; Barnea, Z; Rae, N A; Tran, C Q

    2010-01-01

    The x-ray mass-attenuation coefficients of gold are measured at 91 energies between 14 keV and 21 keV using synchrotron radiation. The measurements are accurate to between 0.08% and 0.1%. The photoelectric mass-absorption coefficients and the imaginary component of the form factors of gold are also determined. The results include the L I edge and are the most accurate and extensive gold dataset available in this energy range. An analysis of the L I edge XAFS showed excellent agreement between the measured and simulated XAFS and yielded highly accurate values of the bond lengths of gold. When our results are compared with earlier measurements and with predictions of major theoretical tabulations, significant discrepancies are noted. The comparison raises questions about the nature of discrepancies between experimental and theoretical values of mass-attenuation coefficients.

  5. Three-dimensional visualization of material flow during friction stir welding by two pairs of X-ray transmission systems

    International Nuclear Information System (INIS)

    Morisada, Y.; Fujii, H.; Kawahito, Y.; Nakata, K.; Tanaka, M.

    2011-01-01

    Material flow during friction stir welding is crucial to obtaining sound joints. However, this phenomenon is still not fully understood despite many investigations and numerous models. In this study, the material flow is three-dimensionally visualized by X-ray radiography using a tiny spherical tungsten tracer. The movement of the tracer during the friction stir welding is observed by two pairs of X-ray transmission real-time imaging systems. The three-dimensional material flow is obtained by following the locus of the tracer.

  6. Effect of spectral shape in the relative efficiency of LiF: Mg,Ti exposed to 20 keV effective energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Ixquiac-Cabrera, J.M., E-mail: mixquiac@nucleares.unam.m [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 DF (Mexico); Departamento de Fisica, Universidad de San Carlos de Guatemala, Edificio T-1 Facultad de Ingenieria (Guatemala); Brandan, M.E.; Martinez-Davalos, A.; Rodriguez-Villafuerte, M.; Ruiz-Trejo, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 DF (Mexico); Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 DF (Mexico)

    2011-04-15

    This work is aimed at studying the possible dependence of the thermoluminescent response of LiF:Mg,Ti (TLD-100) on the X-ray beam spectrum. TLD-100 chips were irradiated with 20 keV effective energy filtered tungsten X-ray spectra, generated by a tube operated at 30, 40, 50, 60, 70 and 80 kV, and the response was measured relative to the response to {sup 60}Co gammas. TLDs were exposed in air at air kerma values between 50 and 300 mGy. Glow curve deconvolution into 8 peaks (3, 4, 5, 6a, 6b, 7, 8 and 9) was performed in order to evaluate the response of individual peaks and regions of interest in the glow curve. Results show that all peaks display a linear response, at least up to 200 mGy, for all X-ray beam qualities. The relative response of the total glow curve area, the dosimetric region (peaks 3 + 4 + 5) and peaks 5 to 9 is statistically constant for beams generated by voltages from 30 to 70 kV; for 80 kV, the values are lower by about 20% for peaks 8 and 9 and 9% for the rest. The relative efficiency for the glow curve area, the dosimetric region and peaks 5 (1.15, 1.10 and 1.13), peaks 8 and 9 (2.05 and 1.55) do not depend on the beam spectrum between 30 and 70 kV, while for 80 kV the efficiency is lower. For peaks 6a, 6b and 7, relative efficiencies (1.91, 2.94 and 2.60) are voltage independent.

  7. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  8. Transmission X-ray Microscopy—A New Tool in Clay Mineral Floccules Characterization

    Directory of Open Access Journals (Sweden)

    Ray L. Frost

    2012-10-01

    Full Text Available Effective flocculation and dewatering of mineral processing streams containing clays are microstructure dependent in clay-water systems. Initial clay flocculation is crucial in the design and for the development of a new methodology of gas exploitation. Microstructural engineering of clay aggregates using covalent cations and Keggin macromolecules have been monitored using the new state of the art Transmission X-ray Microscope (TXM with 60 nm tomography resolution installed in a Taiwanese synchrotron. The 3-D reconstructions from TXM images show complex aggregation structures in montmorillonite aqueous suspensions after treatment with Na+, Ca2+ and Al13 Keggin macromolecules. Na-montmorillonite displays elongated, parallel, well-orientated and closed-void cellular networks, 0.5–3 µm in diameter. After treatment by covalent cations, the coagulated structure displays much smaller, randomly orientated and openly connected cells, 300–600 nm in diameter. The average distances measured between montmorillonite sheets was around 450 nm, which is less than half of the cell dimension measured in Na-montmorillonite. The most dramatic structural changes were observed after treatment by Al13 Keggin; aggregates then became arranged in compacted domains of a 300 nm average diameter composed of thick face-to-face oriented sheets, which forms porous aggregates with larger intra-aggregate open and connected voids.

  9. Scanning transmission X-ray microscopy as a speciation tool for natural organic molecules

    Energy Technology Data Exchange (ETDEWEB)

    Rothe, J.; Plaschke, M.; Denecke, M.A. [Inst. fuer Nukleare Entsorgung, Forschungszentrum Karlsruhe, Karlsruhe (Germany)

    2004-07-01

    A molecular-scale understanding of the basic processes affecting stability and transport behavior of actinide cations, complexes or hydroxide ('eigencolloid') species is prerequisite to performance assessment of nuclear waste disposal in geological formations. Depending on their functional group chemistry and macromolecular structure, naturally occurring organic molecules (NOM) possess a high tendency towards actinide complexation reactions. However, the compositional and structural heterogeneity of NOM and mixed aggregates with inorganic phases makes speciation by spectromicroscopy techniques highly desirable. The applicability of Scanning Transmission X-ray Microscopy (STXM) as a speciation tool for the characterization of NOM is demonstrated for a multifunctional natural organic acid (chlorogenic acid), Eu(III)-loaded humic acid (HA) aggregates and Eu(III)-oxo/hydroxide/HA hetero-aggregates. It is shown that in situ probing of HA functional group chemistry down to a spatial resolution < 100 nm (i.e., less than femto-liter sampled volumes) is feasible, at the same time revealing morphological details on NOM aggregates and NOM/mineral associations. (orig.)

  10. A method for describing the doses delivered by transmission x-ray computed tomography

    International Nuclear Information System (INIS)

    Shope, T.B.; Gagne, R.M.; Johnson, G.C.

    1981-01-01

    A method for describing the absorbed dose delivered by x-ray transmission computed tomography (CT) is proposed which provides a means to characterize the dose resulting from CT procedures consisting of a series of adjacent scans. The dose descriptor chosen is the average dose at several locations in the imaged volume of the central scan of the series. It is shown that this average dose, as defined, for locations in the central scan of the series can be obtained from the integral of the dose profile perpendicular to the scan plane at these same locations for a single scan. This method for estimating the average dose from a CT procedure has been evaluated as a function of the number of scans in the multiple scan procedure and location in the dosimetry phantom using single scan dose profiles obtained from five different types of CT systems. For the higher dose regions in the phantoms, the multiple scan dose descriptor derived from the single scan dose profiles overestimates the multiple scan average dose by no more than 10%, provided the procedure consists of at least eight scans

  11. Development of a new method to characterize low-to-medium energy X-ray beams (E≤150 keV) used in dosimetry

    International Nuclear Information System (INIS)

    Deloule, Sybelle

    2014-01-01

    In the field of dosimetry, the knowledge of the whole photon fluence spectrum is an essential parameter. In the low-to-medium energy range (i.e. E≤150 keV), the LNHB possess 5 X-ray tubes and iodine-125 brachytherapy seeds, both emitting high fluence rates. The performance of calculation (either Monte Carlo codes or deterministic software) is flawed by increasing uncertainties on fundamental parameters at low energies, and modelling issues. Therefore, direct measurement using a high purity germanium is preferred, even though it requires a time-consuming set-up and mathematical methods to infer impinging spectrum from measured ones (such as stripping, model-fitting or Bayesian inference). Concerning brachytherapy, the knowledge of the seed's parameters has been improved. Moreover, various calculated X-ray tube fluence spectra have been compared to measured ones, after unfolding. The results of all these methods have then be assessed, as well as their impact on dosimetric parameters. (author) [fr

  12. X-ray attenuation cross sections for energies 100 eV to 100 keV and elements Z = 1 to Z = 92

    International Nuclear Information System (INIS)

    Saloman, E.B.; Hubbell, J.H.; Scofield, J.H.

    1988-01-01

    This work presents for the energy range 0.1--100 keV the National Bureau of Standards (NBS) database of experimental x-ray attenuation coefficients (total absorption cross sections) and cross sections calculated using a relativistic Hartree--Slater model for the photoelectric cross section for all elements of atomic number Z = 1--92. The information is displayed in both tabular and graphical form. Also shown on the graphs are cross sections obtained using the semiempirical set of recommended values of B. L. Henke and co-workers (Atomic Data and Nuclear Data Tables 27, 1 (1982)). A bibliography of the NBS database for this energy range is included. copyright 1988 Academic Press, Inc

  13. Microtomographic images of rat's lumbar vertebra microstructure using 30 keV synchrotron X-rays: an analysis in terms of 3D visualization

    Science.gov (United States)

    Rao, D. V.; Takeda, T.; Kawakami, T.; Uesugi, K.; Tsuchiya, Y.; Wu, J.; Lwin, T. T.; Itai, Y.; Zeniya, T.; Yuasa, T.; Akatsuka, T.

    2004-05-01

    Microtomographic images of rat's lumbar vertebra of different age groups varying from 8, 56 and 78 weeks were obtained at 30 keV using synchrotron X-rays with a spatial resolution of 12 μm. The images are analyzed in terms of 3D visualization and micro-architecture. Density histogram of rat's lumbar vertebra is compared with test phantoms. Rat's lumbar volume and phantom volume are studied at different concentrations of hydroxyapatite with slice number. With the use of 2D slices, 3D images are reconstructed, in order to know the evolution and a state of decline of bone microstructure with aging. Cross-sectional μ-CT images shows that the bone of young rat has a fine trabecular microstructure while that of the old rat has large meshed structure.

  14. Microtomographic images of rat's lumbar vertebra microstructure using 30 keV synchrotron X-rays: an analysis in terms of 3D visualization

    Energy Technology Data Exchange (ETDEWEB)

    Rao, D.V.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Kawakami, T.; Uesugi, K.; Tsuchiya, Y.; Wu, J.; Lwin, T.T.; Itai, Y.; Zeniya, T.; Yuasa, T.; Akatsuka, T

    2004-05-01

    Microtomographic images of rat's lumbar vertebra of different age groups varying from 8, 56 and 78 weeks were obtained at 30 keV using synchrotron X-rays with a spatial resolution of 12 {mu}m. The images are analyzed in terms of 3D visualization and micro-architecture. Density histogram of rat's lumbar vertebra is compared with test phantoms. Rat's lumbar volume and phantom volume are studied at different concentrations of hydroxyapatite with slice number. With the use of 2D slices, 3D images are reconstructed, in order to know the evolution and a state of decline of bone microstructure with aging. Cross-sectional {mu}-CT images shows that the bone of young rat has a fine trabecular microstructure while that of the old rat has large meshed structure.

  15. Measurement of L X-ray fluorescence cross-sections for elements with 45 ≤ Z ≤ 50 using synchrotron radiation at 8 keV

    International Nuclear Information System (INIS)

    Bonzi, Edgardo V.; Badiger, Nagappa M.; Grad, Gabriela B.; Barrea, Raul A.; Figueroa, Rodolfo G.

    2011-01-01

    The L shell fluorescence cross-sections of the elements in range 45 ≤ Z ≤ 50 have been determined at 8 keV using Synchrotron radiation. The individual L X-ray photons, Ll, Lα, Lβ I , Lβ II , Lγ I and Lγ II produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield Krause and Scofield and Puri et al. . These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lγ, where values measured of this work are slighter higher.

  16. Total L-shell X-ray production cross sections by 400-700 keV proton impact for elements with 34≤Z≤53

    International Nuclear Information System (INIS)

    Miranda, J.; Ledesma, R.; Lucio, O.G. de

    2001-01-01

    Total L-shell X-ray production cross sections induced by protons with energies between 400 and 700 keV were measured for elements with atomic number Z between 34 and 53. The ECPSSR theory describes appropriately the results. This model modifies the plane wave born approximation by considering projectile energy loss (E), Coulomb deflection of the incoming ion (C), polarization and change in electron binding energies through a perturbed stationary states method (PSS) and relativistic values of target electron mass (R). A comparison is given with previously published data for proton energies below 1 MeV and 26 ≤ Z ≤ 53, based on a scaling obtained from a reduced velocity parameter ξ L R . The results show that the scaling for these atomic numbers and energy ranges is adequate and a semi-empirical expression to calculate those cross sections is proposed

  17. Measurement of L x-ray emission from elements in 64 ≤ Z ≤ 73 interval stimulated by 59.54 keV photons

    International Nuclear Information System (INIS)

    Baraldi, C; Casnati, E; Tartari, A; Singh, B

    2005-01-01

    Accurate measurements (mostly within 5%) of L α , L β and L γ x-ray emission cross sections were carried out on thick foils of elements lying in 64 ≤ Z ≤ 73 interval, stimulated by 59.54 keV photons. They can be of help as an overall reference to compare the theoretical and semi-empirical approaches by which the atomic parameters included in the expressions of L emission cross sections are evaluated. An appropriate extension of the expression linking the cross section to the counting rate measured in reflection geometry on thick targets makes it possible to overcome the difficulties arising from the width in energy of the L β and L γ groups and from the jump present in the attenuation coefficients of the target elements within the energy interval of their L γ emission lines

  18. Measurements of Lα, Lβ x-ray production cross sections of Pb by 16-40 keV electron impact

    International Nuclear Information System (INIS)

    Wu, Y; An, Z; Duan, Y M; Liu, M T; Tang, C H

    2007-01-01

    The measurement of L α , L β x-ray production cross sections for the element Pb (Z = 82) by 16-40 keV electron impact is reported in this paper. The target used in the experiment was prepared by evaporating the elemental Pb onto a thick pure carbon substrate. The effects of multiple scattering of electrons when penetrating the target film, of electrons reflected from the thick pure carbon substrate and of bremsstrahlung photons produced by the impact of incident electrons on the target are corrected using the Monte Carlo method. The experimental data, reported here for the first time in the energy region of interest, are compared with the plane-wave Born approximation theory with exchange, Coulomb and relativistic corrections. They are in good agreement

  19. In situ thin film measurement by X-rays induced by 10 KeV-100 KeV ion beams

    International Nuclear Information System (INIS)

    Torrisi, L.; Calcagno, L.; Trovato, A.; Foti, G.

    1982-01-01

    The in situ measurement of thin film thickness between 50 and 100 KeV is described. The method used seems to be flexible enough and can be applied to any type of material. The only parameter intervening in the thickness measurement is the specific energy loss of the proton beams. Film of Al, Cu and Ag have been considered. When the primary beam energy increases the perception in depth of the method grows, reaching 10 μm with 1 MeV beam. In this case the autoabsorption takes place

  20. M-shell X-ray production cross-sections for elements with 67 ≤ Z ≤ 92 at incident photon energies EM1inc≤150keV

    International Nuclear Information System (INIS)

    Chauhan, Yogeshwar; Kumar, Anil; Puri, Sanjiv

    2009-01-01

    The X-ray production cross-sections for the Mk (k = ξ, δ, α, β, ζ, γ, m 1 and m 2 ) groups of X-rays have been evaluated for all the elements with 67 ≤ Z ≤ 92 at incident photon energies ranging E M 1 inc ≤150 keV using currently available theoretical data sets of different physical parameters, namely, partial photoionization cross-sections, X-ray emission rates, fluorescence and Coster-Kronig yields, and the K-shell/L j (j = 1-3) subshell to the M i (i = 1-5) subshell vacancy transfer probabilities, based on the independent particle models.

  1. Measurement of mass attenuation coefficients of Rhizophora spp. binderless particleboards in the 16.59-25.26 keV photon energy range and their density profile using x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marashdeh, M.W., E-mail: mwmarashdeh@yahoo.com [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Bauk, S. [Physics Section, P.P.P. Jarak Jauh, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Tajuddin, A.A. [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hashim, R. [Division of Bio-resource, Paper and Coatings Technology, School of Industrial Technology, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia)

    2012-04-15

    The mass attenuation coefficients of Rhizophora spp. binderless particleboard with four different particle sizes (samples A, B, C and D) and natural raw Rhizophora spp. wood (sample E) were determined using single-beam photon transmission in the energy range between 16.59 and 25.26 keV. This was done by determining the attenuation of K{sub {alpha}1} X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver and tin targets. The results were compared with theoretical values of young-age breast (Breast 1) and water calculated using a XCOM computer program. It was found that the mass attenuation coefficient of Rhizophora spp. binderless particleboards to be close to the calculated XCOM values in water than natural Rhizophora spp. wood. Computed tomography (CT) scans were then used to determine the density profile of the samples. The CT scan results showed that the Rhizophora spp. binderless particleboard has uniform density compared to natural Rhizophora spp. wood. In general, the differences in the variability of the profile density decrease as the particle size of the pellet samples decreases. - Highlights: Black-Right-Pointing-Pointer Mass attenuation coefficients were determined by X-ray fluorescent photons. Black-Right-Pointing-Pointer Sample with smaller particle size found very close to calculated water XCOM. Black-Right-Pointing-Pointer X-ray computed tomography scanner was used to investigate the density distribution. Black-Right-Pointing-Pointer The density distribution profile is improved with the decrease in the particle size. Black-Right-Pointing-Pointer Rhizophora spp. binderless particleboard could be used as phantom material.

  2. Quantifying vertical stress transmission and compaction-induced soil structure using sensor mat and X-ray computed tomography

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Schjønning, Per; Keller, Thomas

    2016-01-01

    tillage. In this study, partially confined uniaxial compression tests were carried out on intact topsoil columns placed on subsoil columns. Two methods were employed for estimation of stress transmission in soil: (i) soil deformation patterns were quantified using X-ray CT and converted to stress......Accurate estimation of stress transmission in soil and quantification of compaction-induced soil pore structure is important for efficient soil use and management. Continuum mechanics have so far mostly been applied for agricultural soils, even if topsoil structure is aggregated due to regular...... distributions, and (ii) a tactile sensor mat was employed for measuring stresses at the interface of the topsoil and subsoil columns. The resulting soil pore structure under applied stresses was quantified using X-ray CT and by air-permeability measurements. In topsoil discrete stress transmission patterns were...

  3. Diffuse x-ray scattering and transmission electron microscopy study of defects in antimony-implanted silicon

    Science.gov (United States)

    Takamura, Y.; Marshall, A. F.; Mehta, A.; Arthur, J.; Griffin, P. B.; Plummer, J. D.; Patel, J. R.

    2004-04-01

    Ion implantation followed by laser annealing has been used to create supersaturated and electrically active concentrations of antimony in silicon. Upon subsequent thermal annealing, however, these metastable dopants deactivate towards the equilibrium solubility limit. In this work, the formation of inactive antimony structures has been studied with grazing incidence diffuse x-ray scattering, and transmission electron microscopy, and the results are correlated to previous high-resolution x-ray diffraction data. We find that at a concentration of 6.0×1020 cm-3, small, incoherent clusters of radius 3-4 Å form during annealing at 900 °C. At a higher concentration of 2.2×1021 cm-3, deactivation at 600 °C occurs through the formation of small, antimony aggregates and antimony precipitates. The size of these precipitates from diffuse x-ray scattering is roughly 15 Å in radius for anneal times from 15 to 180 seconds. This value is consistent with the features observed in high-resolution and mass contrast transmission electron microscopy images. The coherent nature of the aggregates and precipitates causes the expansion of the surrounding silicon matrix as the deactivation progresses. In addition, the sensitivity of the diffuse x-ray scattering technique has allowed us to detect the presence of small clusters of radius ˜2 Å in unprocessed Czochralski silicon wafers. These defects are not observed in floating zone silicon wafers, and are tentatively attributed to thermal donors.

  4. The emission of characteristic and non-characteristic x-rays from collisions of 10-22 keV electrons with argon

    Energy Technology Data Exchange (ETDEWEB)

    Singh, R K; Shanker, R [Atomic Physics Laboratory, Department of Physics, Banaras Hindu University, Varanasi-221 005 (India)

    2003-07-28

    Measurements of the emission cross sections of the characteristic and the non-characteristic x-rays produced from collisions of 10-22 keV electrons with Ar atoms are presented. The relative cross sections for Ar K-shell ionization as a function of impact energy are shown to yield satisfactory agreement (within the experimental uncertainty) with Born-Ochkur calculations and with results obtained from an empirical formula proposed by Hombourger (1998 J. Phys. B: At. Mol. Opt. Phys. 31 3693). Furthermore, the double differential cross sections of bremsstrahlung photons emitted from 10-22 keV e{sup -}-Ar collisions as a function of impact energy for different photon energies were measured. The shape of the experimental bremsstrahlung cross section function is found to exhibit good agreement with the theoretical calculations of Kissel et al (1983 At. Data Nucl. Data Tables 28 381) within the experimental uncertainty. In addition, the shape of the angular distributions of the bremsstrahlung is in accord with the calculations of Kissel et al and those of the modified Sommerfeld (Kulenkampff et al 1959 Z. Phys. 157 275) formula.

  5. Linear and mass attenuation coefficient for CdTe compound of X-rays from 10 to 100 keV energy range in different phases

    Energy Technology Data Exchange (ETDEWEB)

    Saim, A., E-mail: saim1989asma@gmail.com; Tebboune, A.; Berkok, H.; Belameiri, N.; Belbachir, A.H.

    2014-07-25

    The Full Potential Linear Muffin Tin Orbitals method within the density functional theory has been utilized to calculate structural and electronic properties of the CdTe compound. We have checked that the CdTe has two phase-transitions from zinc-blend to cinnabar and from cinnabar to rocksalt. We have found that the rigidity, the energy and the nature of the gap change according to the phase change, so we can predict that a CdTe detector may have different behaviors in different phase conditions. In order to investigate this behavior change, the linear and the mass attenuation coefficients of X-ray in rocksalt, zinc-blend and cinnabar structures are calculated from 10 keV to100 keV, using the XCOM data. We have found that when CdTe undergoes a phase transition from zinc-blend to cinnabar, its linear attenuation coefficient decreases down to a value of about 100 times smaller than its initial one, and when it undergoes a transition from cinnabar to rocksalt it increases up to a value about 90 times larger than its initial one.

  6. Depth profiling: RBS versus energy-dispersive X-ray imaging using scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Markwitz, Andreas

    2000-01-01

    Rutherford backscattering spectrometry (RBS) is known to be one of the techniques ideal for analysis of thin films. Elemental concentrations of matrix components and impurities can be investigated as well as depth profiles of almost each element of the periodic table. Best of all, RBS has both a high sensitivity and a high depth resolution, and is a non-destructive analysis technique that does not require specific sample preparation. Solid-state samples are mounted without preparation inside a high-vacuum analysis chamber. However, depth-related interpretation of elemental depth profiles requires the material density of the specimen and stopping power values to be taken into consideration. In many cases, these parameters can be estimated with sufficient precision. However, the assumed density can be inaccurate for depth scales in the nanometer range. For example, in the case of Ge nanoclusters in 500 nm thick SiO 2 layers, uncertainty is related to the actual position of a very thin Ge nanocluster band. Energy-dispersive X-ray emission (EDX) spectroscopy, using a high-resolution scanning transmission electron microscope (STEM) can assist in removing this uncertainty. By preparing a thin section of the specimen, EDX can be used to identify the position of the Ge nanocluster band very precisely, by correlating the Ge profile with the depth profiles of silicon and oxygen. However, extraction of the concentration profiles from STEM-EDX spectra is in general not straightforward. Therefore, a combination of the two very different analysis techniques is often the best and only successful way to extract high-resolution concentration profiles

  7. Synchrotron-based transmission x-ray microscopy for improved extraction in shale during hydraulic fracturing

    Science.gov (United States)

    Kiss, Andrew M.; Jew, Adam D.; Joe-Wong, Claresta; Maher, Kate M.; Liu, Yijin; Brown, Gordon E.; Bargar, John

    2015-09-01

    Engineering topics which span a range of length and time scales present a unique challenge to researchers. Hydraulic fracturing (fracking) of oil shales is one of these challenges and provides an opportunity to use multiple research tools to thoroughly investigate a topic. Currently, the extraction efficiency from the shale is low but can be improved by carefully studying the processes at the micro- and nano-scale. Fracking fluid induces chemical changes in the shale which can have significant effects on the microstructure morphology, permeability, and chemical composition. These phenomena occur at different length and time scales which require different instrumentation to properly study. Using synchrotron-based techniques such as fluorescence tomography provide high sensitivity elemental mapping and an in situ micro-tomography system records morphological changes with time. In addition, the transmission X-ray microscope (TXM) at the Stanford Synchrotron Radiation Lightsource (SSRL) beamline 6-2 is utilized to collect a nano-scale three-dimensional representation of the sample morphology with elemental and chemical sensitivity. We present the study of a simplified model system, in which pyrite and quartz particles are mixed and exposed to oxidizing solution, to establish the basic understanding of the more complex geology-relevant oxidation reaction. The spatial distribution of the production of the oxidation reaction, ferrihydrite, is retrieved via full-field XANES tomography showing the reaction pathway. Further correlation between the high resolution TXM data and the high sensitivity micro-probe data provides insight into potential morphology changes which can decrease permeability and limit hydrocarbon recovery.

  8. Small angle X-ray scattering and transmission electron microscopy study of the Lactobacillus brevis S-layer protein

    Energy Technology Data Exchange (ETDEWEB)

    Jaeaeskelaeinen, Pentti [Department of Biomedical Engineering and Computational Science, PO Box 2200, FI-02015 Aalto University School of Science and Technology (Finland); Engelhardt, Peter [Haartman Institute, Department of Pathology, PO Box 21, FIN-00014 University of Helsinki (Finland); Hynoenen, Ulla; Palva, Airi [Department of Basic Veterinary Sciences, Division of Microbiology, FIN-00014 University of Helsinki (Finland); Torkkeli, Mika; Serimaa, Ritva, E-mail: ritva.serimaa@helsinki.f [Department of Physics, POB 64, 00014 University of Helsinki (Finland)

    2010-10-01

    The structure of self-assembly domain containing recombinant truncation mutants of Lactobacillus brevis surface layer protein SlpA in aqueous solution was studied using small-angle X-ray scattering and transmission electron microscopy. The proteins were found out to interact with each other forming stable globular oligomers of about 10 monomers. The maximum diameter of the oligomers varied between 75 A and 435 A.

  9. Detection methods of pulsed X-rays for transmission tomography with a linear accelerator

    International Nuclear Information System (INIS)

    Glasser, F.

    1988-07-01

    Appropriate detection methods are studied for the development of a high energy tomograph using a linear accelerator for nondestructive testing of bulky objects. The aim is the selection of detectors adapted to a pulsed X-ray source and with a good behavior under X-ray radiations of several MeV. Performance of semiconductors (HgI 2 , Cl doped CdTe, GaAs, Bi 12 Ge0 20 ) and a scintillator (Bi 4 Ge 3 0 12 ) are examined. A prototype tomograph gave images that show the validity of detectors for analysis of medium size equipment such as a concrete drum of 60 cm in diameter [fr

  10. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  11. Observation of dislocations in crystals using X-ray and electron transmission

    International Nuclear Information System (INIS)

    Morlevat, J.P.

    1965-10-01

    Two approaches of the dynamical theory of diffraction (EWALD's and AUTHIER's) are recalled briefly. In the light of these theories, one then considers what information concerning the dislocations existing in a crystal can be obtained by X-Ray as well as electron diffraction. (author) [fr

  12. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  13. Guiding hard x rays with glass polycapillary fiber

    International Nuclear Information System (INIS)

    Xiao, Q.F.; Ponomarev, I.Y.; Kolomitsev, A.I.; Gibson, D.M.; Dilmanian, F.A.; Nachaliel, E.

    1993-01-01

    X rays can be guided through a polycapillary fiber by multiple total reflections from the smooth channel walls of the fiber. Using monochromatic Synchrotron Radiation at energies of 22 and 44 keV, we measured the efficiency of transmission of x rays through polycapillary fibers with channel diameters of about 13 μm. Efficiencies of 57.3% and 54.5% for 22 keV and 44 keV x rays, respectively, were obtained with a 120-mm-long straight polycapillary fiber aligned with the incident beam. These values are close to the open fraction of the fiber, which is about 60%. In addition, transmission efficiency was measured as a function of the tilt angle between the incident beam and the axis of the fiber. We also measured the transmission efficiency as a function of the deflection angle for a 114-mm-long curved polycapillary fiber. The measurements are compared with a ray-tracing simulation

  14. Transmission properties of barite mortar using X-ray spectra measured with Cd Te detector

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J. C.; Mariano, L.; Costa, P. R. [Universidade de Sao Paulo, Instituto de Fisica, Rua do Matao Travessa R. 187, Cidade Universitaria, 05508-090 Sao Paulo (Brazil); Tomal, A., E-mail: josilene@usp.br [Universidade Federal de Goias, Instituto de Fisica, Campus Samambaia, 74001-970 Goiania (Brazil)

    2014-08-15

    Current methods for calculating X-ray shielding barriers do not take into account spectral distribution of the beam transmitted by the protective material. This consideration is important in dose estimations for radiation workers and general public in diagnostic radiology facilities. The aim of the present study was to estimate barite mortar attenuation curves using X-ray spectra weighted by a workload distribution. These curves were described in units of ambient dose equivalent (H (10)), since it is the radiation quantity adopted by IAEA for dose assessment in medical environment. Attenuation curves were determined using the optimized model for shielding evaluation presented by Costa and Caldas (2002). Workload distribution presented by Simpkin (1996), measured primary spectra and mass attenuation coefficients of barite mortar were used as input data in this model. X-ray beams in diagnostic energy range were generated by an industrial X-ray tube with 3 mm of aluminum additional filtration. Primary experimental spectra were measured by a Cd Te detector and corrected by the response function of detector by means of a stripping procedure. Air kerma measurements were performed using an ionization chamber for normalization purpose of the spectra. The corrected spectra presented good agreement with spectra generated by a semi-empirical model. The variation of the ambient dose equivalent as a function of barite mortar thickness was calculated. Using these data, it was estimated the optimized thickness of protective barrier needed for shielding a particular area in an X-ray imaging facility. The results obtained for primary protective barriers exhibit qualitative agreement with those presented in literature. (Author)

  15. Explaining the 3.5 keV X-ray line in a Lμ‑Lτ extension of the inert doublet model

    Science.gov (United States)

    Biswas, Anirban; Choubey, Sandhya; Covi, Laura; Khan, Sarif

    2018-02-01

    We explain the existence of neutrino masses and their flavour structure, dark matter relic abundance and the observed 3.5 keV X-ray line within the framework of a gauged U(1)Lμ ‑ Lτ extension of the "scotogenic" model. In the U(1)Lμ ‑ Lτ symmetric limit, two of the RH neutrinos are degenerate in mass, while the third is heavier. The U(1)Lμ ‑ Lτ symmetry is broken spontaneously. Firstly, this breaks the μ‑τ symmetry in the light neutrino sector. Secondly, this results in mild splitting of the two degenerate RH neutrinos, with their mass difference given in terms of the U(1)Lμ ‑ Lτ breaking parameter. Finally, we get a massive Zμτ gauge boson. Due to the added Z2 symmetry under which the RH neutrinos and the inert doublet are odd, the canonical Type-I seesaw is forbidden and the tiny neutrino masses are generated radiatively at one loop. The same Z2 symmetry also ensures that the lightest RH neutrino is stable and the other two can only decay into the lightest one. This makes the two nearly-degenerate lighter neutrinos a two-component dark matter, which in our model are produced by the freeze-in mechanism via the decay of the Zμτ gauge boson in the early universe. We show that the next-to-lightest RH neutrino has a very long lifetime and decays into the lightest one at the present epoch explaining the observed 3.5 keV line.

  16. Composition measurement in substitutionally disordered materials by atomic resolution energy dispersive X-ray spectroscopy in scanning transmission electron microscopy.

    Science.gov (United States)

    Chen, Z; Taplin, D J; Weyland, M; Allen, L J; Findlay, S D

    2017-05-01

    The increasing use of energy dispersive X-ray spectroscopy in atomic resolution scanning transmission electron microscopy invites the question of whether its success in precision composition determination at lower magnifications can be replicated in the atomic resolution regime. In this paper, we explore, through simulation, the prospects for composition measurement via the model system of Al x Ga 1-x As, discussing the approximations used in the modelling, the variability in the signal due to changes in configuration at constant composition, and the ability to distinguish between different compositions. Results are presented in such a way that the number of X-ray counts, and thus the expected variation due to counting statistics, can be gauged for a range of operating conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  18. Lα and Mαβ X-ray production cross-sections of Bi by 6-30 keV electron impact

    Science.gov (United States)

    Liang, Y.; Xu, M. X.; Yuan, Y.; Wu, Y.; Qian, Z. C.; Chang, C. H.; Mei, C. S.; Zhu, J. J.; Moharram, K.

    2017-12-01

    In this paper, the Lα and Mαβ X-ray production cross-sections for Bi impacted by 6-30 keV electron have been measured. The experiments were performed at a Scanning Electron Microscope equipped with a silicon drift detector. The thin film with thick C substrate and the thin film deposited on self-supporting thin C film were both used as the targets to make a comparison. For the thick carbon substrate target, the Monte Carlo method has been used to eliminate the contribution of backscattering particles. The measured data are compared with the DWBA theoretical model and the experimental results in the literature. The experimental data for the thin film with thick C substrate target and the thin film deposited on self-supporting thin C film target are within reasonable gaps. The DWBA theoretical model gives good fit to the experimental data both for L- and M- shells. Besides, we also analyze the reasons why the discrepancies exist between our measurements and the experimental results in the literature.

  19. X-ray variability of the BL Lacertae object PKS 2155 - 304 in the 0.1-6 keV range

    International Nuclear Information System (INIS)

    Morini, M.; Chiappetti, L.; Maccagni, D.; Maraschi, L.; Molteni, D.; CNR, Istituto di Fisica Cosmica, Milan, Italy; CNR, Istituto di Fisica Cosmica; Milano Universita, Italy; Palermo Universita, Italy)

    1986-01-01

    Observations of the bright BL Lac object PKS 2155 - 304 obtained at 1-6 keV using the ME argon counters and channel-multiplier array at the focus of the Exosat LE telescope, in conjunction with the 0.05-2-keV-bandpass 3000-A Lexan filter, during a total of 30 h in October-November 1983 and November 1984 are reported. The data are presented in tables and graphs and characterized. Findings discussed include an overall variation of a factor of 10, one factor-of-four increase over 4 h, and maximum luminosity variation dL/dt = 2 x 10 to the 42nd erg/s sq for H = 100 km/s Mpc (corresponding to a lower limit of mass of 10 to the 8th solar mass and a gravitational radius of 3 x 10 to the 13th cm). The implications of these results for theoretical models of the X-ray emission source are considered. 17 references

  20. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements

    Energy Technology Data Exchange (ETDEWEB)

    Seidler, G. T., E-mail: seidler@uw.edu; Mortensen, D. R.; Remesnik, A. J.; Pacold, J. I.; Ball, N. A.; Barry, N.; Styczinski, M.; Hoidn, O. R. [Physics Department, University of Washington, Seattle, Washington 98195-1560 (United States)

    2014-11-15

    We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 10{sup 6}–10{sup 7} photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.

  1. Effect of external magnetic field on the Kβ/Kα X-ray intensity ratios of TixNi1-x alloys excited by 59.54 and 22.69keV photons.

    Science.gov (United States)

    Perişanoğlu, Ufuk; Alım, Bünyamin; Uğurlu, Mine; Demir, Lütfü

    2016-09-01

    The effects of external magnetic field and exciting photon energies on the Kβ/Kα X-ray intensity ratios of various alloy compositions of Ti-Ni transition metal alloys have been investigated in this work using X-ray fluorescence spectroscopy. The spectrum of characteristic K-X-ray photons from pure Ti, pure Ni and TixNi1-x (x=0.30; 0.40; 0.50; 0.60; 0.70) alloys were detected with a high resolution Si (Li) solid-state detector. Firstly, Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni and TixNi1-x alloys were measured following excitation by 59.54keV γ-rays from a 200mCi (241)Am radioactive point source without any magnetic field and under 0.5 and 1T external magnetic fields, separately. Later, the same measurements were repeated under the same experimental conditions for 22.69keV X-rays from a 370 MBq(1)(0)(9)Cd radioactive point source. The results obtained for Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni, Ti and Ni in various Ti-Ni alloys were evaluated in terms of both external magnetic field effect and exciting photon energy effect. When the results obtained for both exciting photon energies are evaluated in terms of changing of Kβ/Kα X-ray intensity ratios depending on the alloy composition, the tendency of these changes are observed to be similar. Also, Kβ/Kα X-ray intensity ratios for all samples examined have changed with increasing external magnetic field. Therefore, the results obtained have shown that Kβ/Kα X-ray intensity ratios of Ti and Ni in TixNi1-x alloys are connected with the external magnetic field. The present study makes it possible to perform reliable interpretation of experimental Kβ/Kα X-ray intensity ratios for Ti, Ni and TixNi1-x alloys and can also provide quantitative information about the changes of the Kβ/Kα X-ray intensity ratios of these metals with alloy composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Compact, rugged in-chamber transmission spectrometers (7-28 keV) for the Sandia Z facility.

    Science.gov (United States)

    Sinars, D B; Wenger, D F; Pikuz, S A; Jones, B; Geissel, M; Hansen, S B; Coverdale, C A; Ampleford, D J; Cuneo, M E; McPherson, L A; Rochau, G A

    2011-06-01

    We describe a pair of time-integrated transmission spectrometers that are designed to survey 7-28 keV (1.9 to 0.43 Å) x-ray photons produced by experiments on the Sandia Z pulsed power facility. Each spectrometer uses a quartz 10-11 crystal in a Cauchois geometry with a slit to provide spatial resolution along one dimension. The spectrometers are located in the harsh environment of the Z vacuum chamber, which necessitates that their design be compact and rugged. Example data from calibration tests and Z experiments are shown that illustrate the utility of the instruments. © 2011 American Institute of Physics

  3. A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Ewald, J.; Nisius, T.; Abbati, G.; Baumbach, S.; Overbuschmann, J.; Wilhein, T. [Institute for X-Optics (IXO), Hochschule Koblenz, Joseph-Rovan-Allee 2, 53424 Remagen (Germany); Wessels, P.; Wieland, M.; Drescher, M. [The Hamburg Centre for Ultrafast Imaging (CUI), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg (Germany); Institut für Experimentalphysik, University of Hamburg, Luruper Chaussee 149, 22761 Hamburg (Germany); Vogel, A. [Institut für Angewandte Physik, University of Hamburg, Jungiusstraße 11, 20355 Hamburg (Germany); Viefhaus, J. [Deutsches Elektronen-Synchrotron (DESY), Notkestraße 85, 22607 Hamburg (Germany); Meier, G. [The Hamburg Centre for Ultrafast Imaging (CUI), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg (Germany); Max Planck Institute for the Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg (Germany)

    2016-01-28

    Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.

  4. On the wide-energy-range tuning of x-ray photoemission electron microscope optics for the observation of the photoelectrons excited by several keV x-rays

    International Nuclear Information System (INIS)

    Yasufuku, H.; Yoshikawa, H.; Kimura, M.; Vlaicu, A.M.; Kato, M.; Kudo, M.; Fujikata, J.; Fukushima, S.

    2006-01-01

    We have newly developed an x-ray photoemission electron microscope (XPEEM) which uses both soft x-rays and hard x-rays at the undulator beam line BL15XU in the synchrotron radiation (SR) facility SPring-8 to observe various practical materials. In combination with an energy analyzer and high brilliant x-ray source, the detection of high kinetic energy inner-shell photoelectrons is essential for revealing the chemical properties of specimen subsurfaces or buried interfaces, owing to long inelastic mean free path of the high kinetic energy photoelectrons. The most significant result in our design is the new combined electric and magnetic field objective lens in which the magnetic field penetrates up to the sample surface. This allows the measurement with high spatial resolution of both low intensity images of inner-shell photoelectrons with high kinetic energy and high intensity images of secondary electrons. By using the sample bias scan method, we can easily change the focus condition of the objective lens in order to allow the energy filtered imaging with photoelectrons having the kinetic energy in a wide range (1-10 000 eV). By the combination of high brilliant SR x-rays, the new objective lens, and sample bias method, our XPEEM can successfully obtain the microarea x-ray photoelectron spectra and energy filtered XPEEM images of inner-shell photoelectrons, such as Si 1s, without any surface cleaning procedure. The energy filtered XPEEM image using photoelectrons from deep inner shells, Si 1s, was obtained for the first time

  5. Dose and induction to cancer risk evaluation associated to use of X ray body scanners by transmission at airports

    International Nuclear Information System (INIS)

    Correa, Samanda Cristine Arruda; Aquino, Josilto Oliveira de; Souza, Edmilson Monteiro de; Silva, Ademir Xavier da

    2011-01-01

    This paper uses the Monte Carlo MCNPX and the phantoms in male voxel and female voxel to evaluate the absorbed doses effective doses and the induction risk and the mortality due to cancer associated to exposures of individual submitted to X ray body scanners by transmission at various projections. The values of effective dose were calculated according to the recommended by the new ICRP 103 and the values of induction risks and mortality due to cancer were estimated through the document BEIR VII. (author)

  6. Microstructural characterization of industrial foams by gamma ray transmission and X-ray microtomography; Caracterizacao microestrutural de espumas industriais por transmissao de raios gama e microtomografia de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Luiz Eduardo

    2004-07-01

    This work presents the total porosity measurements of the aluminum and silicon carbide (SiC) foams samples. For porosity determination the gamma ray transmission and X-ray microtomography with conic beam techniques were used. These methods have more advantage than conventional ones, because they are non destructive and provide more details of the analyzed material porous structure. The aluminum foam samples with 10, 20, 30, 40 and 45 ppi (pores per inch) and SiC ceramic foam samples with 20, 30, 45, 60, 75, 80 and 90 ppi were analysed by gamma transmission. The SiC 60, 75 and 90 ppi samples were also analyzed by X-ray microtomography. For the gamma ray transmission measurements it was used an {sup 241} Am source (59.53 keV), a NaI(Tl) scintillation detector, collimators, a XYZ micrometric table and standard gamma spectrometry electronics connected to a multichannel analyzer, at the LFNA/UEL. For the X-ray microtomographic measurements, the Fein Focus X-ray system of the Nuclear Instrumentation Laboratory of the COPPE, located at the Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, was used. This equipment provide us images with micrometric resolution (53.48 {mu}m) using a conic X-ray beam and bidimensional detection. The microtomographic images were pre-processed and analyzed by the Imago software, developed at Porous Media and Materials Thermophysical Properties Laboratory (LMPT) of the Mechanical Engineering Department, located at Universidade Federal de Santa Catarina, Florianopolis, SC. Employing the The Imago software it was calculated the total porosity, pore size distribution and autocorrelation function C(u) of the binarized microtomographic images of the each sample. The microtomographic 3-D image of each sample was compared with 3-D image reconstructed by the Gaussian truncated method. This method generates a periodic 3-D porous structure by using of the autocorrelation function of one 2-D cross sectional image of the sample. (author)

  7. Calculated efficiencies of three-material low stress coatings for diffractive x-ray transmission optics

    International Nuclear Information System (INIS)

    Kubec, Adam; Braun, Stefan; Gawlitza, Peter; Menzel, Maik; Leson, Andreas

    2016-01-01

    Diffractive X-ray optical elements made by thin film coating techniques such as multilayer Laue lenses (MLL) and multilayer zone plates (MZP) are promising approaches to achieve resolutions in hard X-ray microscopy applications of less than 10 nm. The challenge is to make a lens with a large numerical aperture on the one hand and a decent working distance on the other hand. One of the limiting factors with the coated structures is the internal stress in the films, which can lead to significant bending of the substrate and various types of unwanted diffraction effects. Several approaches have been discussed to overcome this challenge. One of these is a three-material combination such as Mo/MoSi_2/Si, where four single layers per period are deposited. Mo and Si represent the absorber and spacer in this case while MoSi_2 forms a diffusion barrier; in addition the thicknesses of absorber and spacer are chosen to minimize residual stress of the overall coating. Here the diffraction efficiency as well as the profile of the beam in the focal plane are discussed in order to find a tradeoff between lowest residual stress and best diffraction properties.

  8. Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser

    NARCIS (Netherlands)

    Andreasson, J.; Iwan, B.; Andrejczuk, A.; Abreu, E.; Bergh, M.; Caleman, C.; Nelson, A. J.; Bajt, S.; Chalupsky, J.; Chapman, H. N.; Faustlin, R. R.; Hajkova, V.; Heimann, P. A.; Hjorvarsson, B.; Juha, L.; Klinger, D.; Krzywinski, J.; Nagler, B.; Palsson, G. K.; Singer, W.; Seibert, M. M.; Sobicrajski, R.; Tolcikis, S.; Tschentscher, T.; Vinko, S. M.; Lee, R. W.; Hajdu, J.; Timneanu, N.

    2011-01-01

    Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray

  9. Rapid simulation of X-ray transmission imaging for baggage inspection via GPU-based ray-tracing

    Science.gov (United States)

    Gong, Qian; Stoian, Razvan-Ionut; Coccarelli, David S.; Greenberg, Joel A.; Vera, Esteban; Gehm, Michael E.

    2018-01-01

    We present a pipeline that rapidly simulates X-ray transmission imaging for arbitrary system architectures using GPU-based ray-tracing techniques. The purpose of the pipeline is to enable statistical analysis of threat detection in the context of airline baggage inspection. As a faster alternative to Monte Carlo methods, we adopt a deterministic approach for simulating photoelectric absorption-based imaging. The highly-optimized NVIDIA OptiX API is used to implement ray-tracing, greatly speeding code execution. In addition, we implement the first hierarchical representation structure to determine the interaction path length of rays traversing heterogeneous media described by layered polygons. The accuracy of the pipeline has been validated by comparing simulated data with experimental data collected using a heterogenous phantom and a laboratory X-ray imaging system. On a single computer, our approach allows us to generate over 400 2D transmission projections (125 × 125 pixels per frame) per hour for a bag packed with hundreds of everyday objects. By implementing our approach on cloud-based GPU computing platforms, we find that the same 2D projections of approximately 3.9 million bags can be obtained in a single day using 400 GPU instances, at a cost of only 0.001 per bag.

  10. Compton polarimetry of 6-35 keV X-rays. Influence of Breit interaction on the linear polarisation of KLL dielectronic recombination transitions in highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Joerg, Holger Eric

    2016-12-21

    The polarisation of X-rays emitted during K shell dielectronic recombination (DR) into highly charged ions was studied using electron beam ion traps. In the first experiment, the degree of linear polarisation of X-rays due to K shell DR transitions of highly charged krypton ions was measured with a newly developed Compton polarimeter based on SiPIN diodes. Such polarisation measurements allow a study of the population mechanism of magnetic sublevels in collisions between electrons and ions. In a second experiment, the influence of Breit interaction between electrons on the polarisation of X-rays emitted during K shell DR into highly charged xenon ions was studied. Here, polarisation measurements provide an access to the finer details of the electron-electron interaction in electron-ion collisions. Furthermore, a second Compton polarimeter based on silicon drift detectors has been developed for polarisation measurements at synchrotrons. It has been developed for X-ray polarimetry with a high energy resolution for energies between 6 keV and 35 keV. It was tested in the course of polarisation measurements at an electron beam ion trap and at a synchrotron radiation source.

  11. The NuSTAR Extragalactic Survey: First Direct Measurements of the Greater Than Or Similar To 10 Kev X-Ray Luminosity Function For Active Galactic Nuclei At z > 0.1

    DEFF Research Database (Denmark)

    Aird, J.; Alexander, D. M.; Ballantyne, D. R.

    2015-01-01

    We present the first direct measurements of the rest-frame 10-40 keV X-ray luminosity function (XLF) of active galactic nuclei (AGNs) based on a sample of 94 sources at 0.1 ... program. Our results are consistent with the strong evolution of the AGN population seen in prior, lower-energy studies of the XLF. However, different models of the intrinsic distribution of absorption, which are used to correct for selection biases, give significantly different predictions for the total...... component (with a relative normalization of R ∼ 2 at all luminosities) can bring extrapolations of the XLF from 2-10 keV into agreement with our NuSTAR sample. Ultimately, X-ray spectral analysis of the NuSTAR sources is required to break this degeneracy between the distribution of absorbing column...

  12. X-ray diagnostic in gas discharge

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Cui Gaoxian; Wang Mei; Fu Yibei; Zhang Xinwei; Zhang Wushou

    1995-01-01

    X rays were observed when the anomalous phenomenon in the metal loaded with deuterium studied by the gas-discharge method. Therefore the X-ray energy spectra were measured by the absorption method, the specific X-ray approach and the NaI scintillation counter, while X-ray intensity was estimated by using 7 Li thermoluminescent foils. The X-ray average energy measured by the absorption method is 27.6 +- 2.1 keV, which is fitted within the error extent to 26.0 +-2.4 keV monoenergetic X rays measured by the NaI scintillation counter

  13. Biological effect of ultrasoft x-ray, 1

    International Nuclear Information System (INIS)

    Narita, Noboru

    1985-01-01

    Biological effect on Escherichia coli by ultrasoft X-ray have been studied by comparing with that by uv light (2537 A) and by soft X-ray (40 kVp, 5 mA). Ultrasoft X-ray is aluminium characteristic X-ray (about 1.5 keV) produced by low energy electron collision on aluminium foil target and is obtained from Lea-type transmission target discharge tube. Escherichia coli used here are AB1157, AB1886 (uvrA6), JC1569 (recA), AB2470 (recB) and AB2480 (uvr rec) for inactivation experiment and WP2, WP2uvrA, WP2pKM101 and WP2uvrApKM101 for mutation induction experiment. These strains are all irradiated in buffer. Results obtained are summerized as follows : (i) inactivation by ultrasoft X-ray is located between ones by uv light and by soft X-ray, or ultrasoft X-ray gives a lethal damage that uvrA6 gene seems to contribute, and (ii) ultrasoft X-ray does not show the remarkable mutation induction like that induced by low dose irradiation of uv light or soft X-ray. (author)

  14. Pair distribution functions of amorphous organic thin films from synchrotron X-ray scattering in transmission mode

    Directory of Open Access Journals (Sweden)

    Chenyang Shi

    2017-09-01

    Full Text Available Using high-brilliance high-energy synchrotron X-ray radiation, for the first time the total scattering of a thin organic glass film deposited on a strongly scattering inorganic substrate has been measured in transmission mode. The organic thin film was composed of the weakly scattering pharmaceutical substance indomethacin in the amorphous state. The film was 130 µm thick atop a borosilicate glass substrate of equal thickness. The atomic pair distribution function derived from the thin-film measurement is in excellent agreement with that from bulk measurements. This ability to measure the total scattering of amorphous organic thin films in transmission will enable accurate in situ structural studies for a wide range of materials.

  15. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.

    Science.gov (United States)

    Platten, David John

    2014-06-01

    Existing data used to calculate the barrier transmission of scattered radiation from computed tomography (CT) are based on primary beam CT energy spectra. This study uses the EGSnrc Monte Carlo system and Epp user code to determine the energy spectra of CT scatter from four different primary CT beams passing through an ICRP 110 male reference phantom. Each scatter spectrum was used as a broad-beam x-ray source in transmission simulations through seventeen thicknesses of lead (0.00-3.50 mm). A fit of transmission data to lead thickness was performed to obtain α, β and γ parameters for each spectrum. The mean energy of the scatter spectra were up to 12.3 keV lower than that of the primary spectrum. For 120 kVp scatter beams the transmission through lead was at least 50% less than predicted by existing data for thicknesses of 1.5 mm and greater; at least 30% less transmission was seen for 140 kVp scatter beams. This work has shown that the mean energy and half-value layer of CT scatter spectra are lower than those of the corresponding primary beam. The transmission of CT scatter radiation through lead is lower than that calculated with currently available data. Using the data from this work will result in less lead shielding being required for CT scanner installations.

  16. Electroadsorption-assisted direct determination of trace arsenic without interference using transmission X-ray fluorescence spectroscopy.

    Science.gov (United States)

    Jiang, Tian-Jia; Guo, Zheng; Liu, Jin-Huai; Huang, Xing-Jiu

    2015-08-18

    An analytical technique based on electroadsorption and transmission X-ray fluorescence (XRF) for the quantitative determination of arsenic in aqueous solution with ppb-level limits of detection (LOD) is proposed. The approach uses electroadsorption to enhance the sensitivity and LOD of the arsenic XRF response. Amine-functionalized carbonaceous microspheres (NH2-CMSs) are found to be the ideal materials for both the quantitative adsorption of arsenic and XRF analysis due to the basic amine sites on the surface and their noninterference in the XRF spectrum. In electroadsorptive X-ray fluorescence (EA-XRF), arsenic is preconcentrated by a conventional three-electrode system with a positive electricity field around the adsorbents. Then, the quantification of arsenic on the adsorbents is achieved using XRF. The electroadsorption preconcentration can realize the fast transfer of arsenic from the solution to the adsorbents and improve the LOD of conventional XRF compared with directly determining arsenic solution by XRF alone. The sensitivity of 0.09 cnt ppb(-1) is obtained without the interferences from coexisted metal ions in the determination of arsenic, and the LOD is found to be 7 ppb, which is lower than the arsenic guideline value of 10 ppb given by the World Health Organization (WHO). These results demonstrated that XRF coupled with electroadsorption was able to determine trace arsenic in real water sample.

  17. Absolutely calibrated, time-resolved measurements of soft x rays using transmission grating spectrometers at the Nike Laser Facility

    International Nuclear Information System (INIS)

    Weaver, J.L.; Feldman, U.; Seely, J.F.; Holland, G.; Serlin, V.; Klapisch, M.; Columbant, D.; Mostovych, A.

    2001-01-01

    Accurate simulation of pellet implosions for direct drive inertial confinement fusion requires benchmarking the codes with experimental data. The Naval Research Laboratory (NRL) has begun to measure the absolute intensity of radiation from laser irradiated targets to provide critical information for the radiatively preheated pellet designs developed by the Nike laser group. Two main diagnostics for this effort are two spectrometers incorporating three detection systems. While both spectrometers use 2500 lines/mm transmission gratings, one instrument is coupled to a soft x-ray streak camera and the other is coupled to both an absolutely calibrated Si photodiode array and a charge coupled device (CCD) camera. Absolute calibration of spectrometer components has been undertaken at the National Synchrotron Light Source at Brookhaven National Laboratories. Currently, the system has been used to measure the spatially integrated soft x-ray flux as a function of target material, laser power, and laser spot size. A comparison between measured and calculated flux for Au and CH targets shows reasonable agreement to one-dimensional modeling for two laser power densities

  18. Scanning transmission x-ray microscopy of polymer nanoparticles: probing morphology on sub-10 nm length scales.

    Science.gov (United States)

    Burke, Kerry B; Stapleton, Andrew J; Vaughan, Ben; Zhou, Xiaojing; Kilcoyne, A L David; Belcher, Warwick J; Dastoor, Paul C

    2011-07-01

    Water-processable nanoparticle dispersions of semiconducting polymers offer an attractive approach to the fabrication of organic electronic devices since they offer: (1) control of nanoscale morphology and (2) environmentally friendly fabrication. Although the nature of phase segregation in these polymer nanoparticles is critical to device performance, to date there have been no techniques available to directly determine their intra-particle structure, which consequently has been poorly understood. Here, we present scanning transmission x-ray microscopy (STXM) compositional maps for nanoparticles fabricated from poly(9,9-dioctyl-fluorene-2,7-diyl-co-bis-N, N'-(4-butylphenyl)-bis-N, N'-phenyl-1,4-phenylenedi-amine) (PFB) and poly(9,9-dioctylfluorene-2,7-diyl-co-benzothiadiazole) (F8BT) 1:1 blend mixtures. The images show distinct phase segregation within the nanoparticles. The compositional data reveals that, within these nanoparticles, PFB and F8BT segregate into a core-shell morphology, with an F8BT-rich core and a PFB-rich shell. Structural modelling demonstrates that the STXM technique is capable of quantifying morphological features on a sub-10 nm length scale; below the spot size of the incident focused x-ray beam. These results have important implications for the development of water-based 'solar paints' fabricated from microemulsions of semiconducting polymers.

  19. Scanning transmission x-ray microscopy of polymer nanoparticles: probing morphology on sub-10 nm length scales

    Science.gov (United States)

    Burke, Kerry B.; Stapleton, Andrew J.; Vaughan, Ben; Zhou, Xiaojing; Kilcoyne, A. L. David; Belcher, Warwick J.; Dastoor, Paul C.

    2011-07-01

    Water-processable nanoparticle dispersions of semiconducting polymers offer an attractive approach to the fabrication of organic electronic devices since they offer: (1) control of nanoscale morphology and (2) environmentally friendly fabrication. Although the nature of phase segregation in these polymer nanoparticles is critical to device performance, to date there have been no techniques available to directly determine their intra-particle structure, which consequently has been poorly understood. Here, we present scanning transmission x-ray microscopy (STXM) compositional maps for nanoparticles fabricated from poly(9,9-dioctyl-fluorene-2,7-diyl-co-bis-N, N'-(4-butylphenyl)-bis-N, N'-phenyl-1,4-phenylenedi-amine) (PFB) and poly(9,9-dioctylfluorene-2,7-diyl-co-benzothiadiazole) (F8BT) 1:1 blend mixtures. The images show distinct phase segregation within the nanoparticles. The compositional data reveals that, within these nanoparticles, PFB and F8BT segregate into a core-shell morphology, with an F8BT-rich core and a PFB-rich shell. Structural modelling demonstrates that the STXM technique is capable of quantifying morphological features on a sub-10 nm length scale; below the spot size of the incident focused x-ray beam. These results have important implications for the development of water-based 'solar paints' fabricated from microemulsions of semiconducting polymers.

  20. Scanning transmission x-ray microscopy of polymer nanoparticles: probing morphology on sub-10 nm length scales

    International Nuclear Information System (INIS)

    Burke, Kerry B; Stapleton, Andrew J; Vaughan, Ben; Zhou Xiaojing; Belcher, Warwick J; Dastoor, Paul C; Kilcoyne, A L David

    2011-01-01

    Water-processable nanoparticle dispersions of semiconducting polymers offer an attractive approach to the fabrication of organic electronic devices since they offer: (1) control of nanoscale morphology and (2) environmentally friendly fabrication. Although the nature of phase segregation in these polymer nanoparticles is critical to device performance, to date there have been no techniques available to directly determine their intra-particle structure, which consequently has been poorly understood. Here, we present scanning transmission x-ray microscopy (STXM) compositional maps for nanoparticles fabricated from poly(9,9-dioctyl-fluorene-2,7-diyl-co-bis-N, N ' -(4-butylphenyl)-bis-N, N ' -phenyl-1,4-phenylenedi-amine) (PFB) and poly(9,9-dioctylfluorene-2,7-diyl-co-benzothiadiazole) (F8BT) 1:1 blend mixtures. The images show distinct phase segregation within the nanoparticles. The compositional data reveals that, within these nanoparticles, PFB and F8BT segregate into a core-shell morphology, with an F8BT-rich core and a PFB-rich shell. Structural modelling demonstrates that the STXM technique is capable of quantifying morphological features on a sub-10 nm length scale; below the spot size of the incident focused x-ray beam. These results have important implications for the development of water-based 'solar paints' fabricated from microemulsions of semiconducting polymers.

  1. Scanning transmission x-ray microscopy of polymer nanoparticles: probing morphology on sub-10 nm length scales

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Kerry B; Stapleton, Andrew J; Vaughan, Ben; Zhou Xiaojing; Belcher, Warwick J; Dastoor, Paul C [Centre for Organic Electronics, University of Newcastle, Callaghan, NSW 2308 (Australia); Kilcoyne, A L David, E-mail: Paul.Dastoor@newcastle.edu.au [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2011-07-01

    Water-processable nanoparticle dispersions of semiconducting polymers offer an attractive approach to the fabrication of organic electronic devices since they offer: (1) control of nanoscale morphology and (2) environmentally friendly fabrication. Although the nature of phase segregation in these polymer nanoparticles is critical to device performance, to date there have been no techniques available to directly determine their intra-particle structure, which consequently has been poorly understood. Here, we present scanning transmission x-ray microscopy (STXM) compositional maps for nanoparticles fabricated from poly(9,9-dioctyl-fluorene-2,7-diyl-co-bis-N, N{sup '}-(4-butylphenyl)-bis-N, N{sup '}-phenyl-1,4-phenylenedi-amine) (PFB) and poly(9,9-dioctylfluorene-2,7-diyl-co-benzothiadiazole) (F8BT) 1:1 blend mixtures. The images show distinct phase segregation within the nanoparticles. The compositional data reveals that, within these nanoparticles, PFB and F8BT segregate into a core-shell morphology, with an F8BT-rich core and a PFB-rich shell. Structural modelling demonstrates that the STXM technique is capable of quantifying morphological features on a sub-10 nm length scale; below the spot size of the incident focused x-ray beam. These results have important implications for the development of water-based 'solar paints' fabricated from microemulsions of semiconducting polymers.

  2. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  3. Development of wave length-dispersive soft x-ray emission spectrometers for transmission electron microscopes - an introduction of valence electron spectroscopy for transmission electron microscopy

    International Nuclear Information System (INIS)

    Terauchi, Masami; Koike, Masato; Fukushima, Kurio; Kimura, Atsushi

    2010-01-01

    Two types of wavelength-dispersive soft X-ray spectrometers, a high-dispersion type and a conventional one, for transmission electron microscopes were constructed. Those spectrometers were used to study the electronic states of valence electrons (bonding electrons). Both spectrometers extended the acceptable energy regions to higher than 2000 eV. The best energy resolution of 0.08 eV was obtained for an Al L-emission spectrum by using the high-dispersion type spectrometer. By using the spectrometer, C K-emission of carbon allotropes, Cu L-emission of Cu 1-x Zn x alloys and Pt M-emission spectra were presented. The FWHM value of 12 eV was obtained for the Pt Mα-emission peak. The performance of the conventional one was also presented for ZnS and a section specimen of a multilayer device. W-M and Si-K emissions were clearly resolved. Soft X-ray emission spectroscopy based on transmission electron microscopy (TEM) has an advantage for obtaining spectra from a single crystalline specimen with a defined crystal setting. As an example of anisotropic soft X-ray emission, C K-emission spectra of single crystalline graphite with different crystal settings were presented. From the spectra, density of states of π- and σ-bondings were separately derived. These results demonstrated a method to analyse the electronic states of valence electrons of materials in the nanometre scale based on TEM. (author)

  4. Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation

    Science.gov (United States)

    Takeda, Tohoru; Yu, Quanwen; Yashiro, Toru; Yuasa, Tetsuya; Hasegawa, Yasuo; Itai, Yuji; Akatsuka, Takao

    1999-09-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT system consists of a silicon (111) channel cut monochromator, an x-ray slit and a collimator for fluorescent x ray detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the fluorescent K(alpha) line, incident monochromatic x-ray was set at 37 keV. The FXCT clearly imaged a human thyroid gland and iodine content was estimated quantitatively. In a case of hyperthyroidism, the two-dimensional distribution of iodine content was not uniform, and thyroid cancer had a small amount of iodine. FXCT can be used to detect iodine within thyroid gland quantitatively and to delineate its distribution.

  5. Coherent hard x-ray focusing optics and applications

    Energy Technology Data Exchange (ETDEWEB)

    Yun, W.B.; Viccaro, P.J.; Chrzas, J.; Lai, B.

    1991-01-01

    Coherent hard x-ray beams with a flux exceeding 10{sup 9} photons/second with a bandwidth of 0.1% will be provided by the undulator at the third generation synchrotron radiation sources such as APS, ESRF, and Spring-8. The availability of such high flux coherent x-ray beams offers excellent opportunities for extending the coherence-based techniques developed in the visible and soft x-ray part of the electromagnetic spectrum to the hard x-rays. These x-ray techniques (e.g., diffraction limited microfocusing, holography, interferometry, phase contrast imaging and signal enhancement), may offer substantial advantages over non-coherence-based x-ray techniques currently used. For example, the signal enhancement technique may be used to enhance an anomalous x-ray or magnetic x-ray scattering signal by several orders of magnitude. Coherent x-rays can be focused to a very small (diffraction-limited) spot size, thus allowing high spatial resolution microprobes to be constructed. The paper will discuss the feasibility of the extension of some coherence-based techniques to the hard x-ray range and the significant progress that has been made in the development of diffraction-limited focusing optics. Specific experimental results for a transmission Fresnel phase zone plate that can focus 8.2 keV x-rays to a spot size of about 2 microns will be briefly discussed. The comparison of measured focusing efficiency of the zone plate with that calculated will be made. Some specific applications of zone plates as coherent x-ray optics will be discussed. 17 refs., 4 figs.

  6. Characterization of pigments applied on archaeological material from Chincha's Culture by x-rays fluorescence and transmission electronic microscopy

    International Nuclear Information System (INIS)

    Lopez M, Alcides; Olivera, Paula

    2007-01-01

    The elementary characterization of some pigments applied in the decoration of recipients used by our ancestors of the Chincha Culture by Energy dispersive X-ray fluorescence (EDXRF)method was allowed. Additionally, the morphological and crystalline characterization by Transmission Electronic Microscopy (TEM) method has been possible. The results have allowed identifying the presence of mercury sulphur (HgS) (cinnabar) in the red pigment on the 'mate'; the black and white pigments are constituted by materials of organic aspect; in the case the dark brown one they are constituted by organic matter and ferric oxide. This work also demonstrates that a portable EDXRF spectrometer is the most suitable for the study of pieces of our cultural patrimony, mainly of those that are difficult to transport from an archaeological place or museum to an analytic laboratory by reason of its dimensions and conservation conditions. (author)

  7. In situ observation of Cu-Ni alloy nanoparticle formation by X-ray diffraction, X-ray absorption spectroscopy, and transmission electron microscopy: Influence of Cu/Ni ratio

    DEFF Research Database (Denmark)

    Wu, Qiongxiao; Duchstein, Linus Daniel Leonhard; Chiarello, Gian Luca

    2014-01-01

    Silica-supported, bimetallic Cu-Ni nanomaterials were prepared with different ratios of Cu to Ni by incipient wetness impregnation without a specific calcination step before reduction. Different in situ characterization techniques, in particular transmission electron microscopy (TEM), X-ray...... diffraction (XRD), and X-ray absorption spectroscopy (XAS), were applied to follow the reduction and alloying process of Cu-Ni nanoparticles on silica. In situ reduction of Cu-Ni samples with structural characterization by combined synchrotron XRD and XAS reveals a strong interaction between Cu and Ni species......, which results in improved reducibility of the Ni species compared with monometallic Ni. At high Ni concentrations silica-supported Cu-Ni alloys form a homogeneous solid solution of Cu and Ni, whereas at lower Ni contents Cu and Ni are partly segregated and form metallic Cu and Cu-Ni alloy phases. Under...

  8. Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range

    International Nuclear Information System (INIS)

    Jonge, Martin D. de; Tran, Chanh Q.; Chantler, Christopher T.; Barnea, Zwi; Dhal, Bipin B.; Cookson, David J.; Lee, Wah-Keat; Mashayekhi, Ali

    2005-01-01

    We use the x-ray extended-range technique (XERT) [Chantler et al., Phys. Rev. A 64, 062506 (2001)] to measure the mass attenuation coefficients of molybdenum in the x-ray energy range of 13.5-41.5 keV to 0.02-0.15 % accuracy. Measurements made over an extended range of the measurement parameter space are critically examined to identify, quantify, and correct where necessary a number of experimental systematic errors. These results represent the most extensive experimental data set for molybdenum and include absolute mass attenuation coefficients in the regions of the x-ray absorption fine structure (XAFS) and x-ray-absorption near-edge structure (XANES). The imaginary component of the atomic form-factor f 2 is derived from the photoelectric absorption after subtracting calculated Rayleigh and Compton scattering cross sections from the total attenuation. Comparison of the result with tabulations of calculated photoelectric absorption coefficients indicates that differences of 1-15 % persist between the calculated and observed values

  9. A compact soft x-ray (0.1–1.2 keV) calibration bench for radiometric measurements using an original versatile Rowland circle grazing incidence monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr

    2017-05-21

    This paper describes an original Rowland circle grazing incidence spectrometer used as a monochromator for a soft x-ray Manson source in order to calibrate both the source and detectors over the 0.1–1.2 keV spectral range. The originality of the instrument lies on a patented vacuum manipulator which allows the simultaneous boarding of two detectors, one (reference) for measuring the monochromatic radiation and the second to be calibrated. In order to achieve this, the vacuum manipulator is able to interchange, in vacuum, one detector with the other in front of the exit slit of the monochromatizing stage. One purpose of this apparatus was to completely eliminate the intrinsic bremsstrahlung emission of the x-ray diode source and isolate each characteristic line for quantitative detector calibrations. Obtained spectral resolution (Δλ/λ<10{sup −2}) and spectral purity (>98%) fully meet this objective. Initially dimensioned to perform calibration of bulky x-ray cameras unfolded on the Laser MégaJoule Facility, other kinds of detector can be obviously calibrated using this instrument. A brief presentation of the first calibration of an x-ray CCD through its quantum efficiency (QE) measurement is included in this paper as example. Comparison with theoretical model for QE and previous measurements at higher energy are finally presented and discussed.

  10. A simplified mathematical model for scattered transmission of X-rays in raw brown coal

    International Nuclear Information System (INIS)

    Braune, M.

    1983-01-01

    A simplified mathematical model is presented which renders it possible to calculate the ash content of lignite from scattered transmission of X radiation taking into account two grain classes, the bulk density, and the fill height. The fine grain is assigned to sand and the coarse one to lignite. The model provides a correlation between the fine grain content and the counting rate

  11. Simulations of X-ray transmission through laser-produced plasmas

    International Nuclear Information System (INIS)

    Yan Jun; Qu Yizhi; Li Jiaming

    1999-01-01

    Using the detailed configuration accounting with the term structures treated by the unresolved transition array model, the authors present a method to calculate the transmission spectra for high-power laser-produced plasmas in local thermodynamic equilibrium. Based on the quantum defect theory, the UTA parameters with high principal quantum numbers can be conveniently calculated with much less computational efforts. This ensure us to handle a huge number of transition arrays from many configurations occurring in typical laser-produced middle-Z and high-Z plasmas

  12. R.b.e. of 50 kVp X-rays and 660 keV γ-rays (137Cs) with respect to the production of DNA damage, repair and cell-killing in Escherichia coli K-12

    International Nuclear Information System (INIS)

    Bonura, T.; Youngs, D.A.; Smith, K.C.

    1975-01-01

    A comparison has been made of the efficiency of cell-killing, DNA single-strand breakage and double-strand breakage in an Escherichia coli K-12 wild-type strain after irradiation with soft X-rays (50 kVp) and hard γ-rays (660 keV) under aerobic conditions. Irradiation with 50 kVp X-rays resulted in 1.47 times more cell-killing than was observed with 137 Cs γ-rays based on a comparison of D 0 values evaluated from the survival curves. DNA sedimentation studies showed that, although 50 kVp X-rays were 1.93 times more effective than 137 Cs γ-rays in producing DNA double-strand breaks, there was no significant difference between the two qualities of radiation with respect to the initial number of single-strand breaks produced. When the cells were irradiated and allowed to repair maximally in minimal medium, 1.57 times more unrepaired DNA single-strand breaks remained per krad after irradiation with 50 kVp X-rays than with 137 Cs γ-rays. The increased yield of DNA double-strand breaks resulting from 50 kVp X-irradiation may account for most of these additional unrepaired single-strand breaks, since single- and double-strand breaks are indistinguishable on alkaline sucrose gradients. These results suggest that the greater r.b.e. of 50 kVp X-rays may be related to an increased effectiveness for producing DNA double-strand breaks compared with the higher energy 137 Cs γ-rays. (author)

  13. Transmission X-ray Diffraction (XRD) Patterns Relevant to the MSL Chemin Amorphous Component: Sulfates And Silicates

    Science.gov (United States)

    Morris, R. V.; Rampe, E. B.; Graff, T. G.; Archer, P. D., Jr.; Le, L.; Ming, D. W.; Sutter, B.

    2015-01-01

    The Mars Science Laboratory (MSL) CheMin instrument on the Curiosity rover is a transmission X-ray diffractometer (Co-Kalpha radiation source and a approx.5deg to approx.52deg 2theta range) where the analyzed powder samples are constrained to have discrete particle diameters XRD amorphous component. Estimates of amorphous component abundance, based on the XRD data itself and on mass-balance calculations using APXS data crystalline component chemistry derived from XRD data, martian meteorites, and/or stoichiometry [e.g., 6-9], range from approx.20 wt.% to approx.50 wt.% of bulk sample. The APXSbased calculations show that the amorphous component is rich in volatile elements (esp. SO3) and is not simply primary basaltic glass, which was used as a surrogate to model the broad band in the RN CheMin pattern. For RN, the entire volatile inventory (except minor anhydrite) is assigned to the amorphous component because no volatile-bearing crystalline phases were reported within detection limits [2]. For JK and CB, Fesaponite, basanite, and akaganeite are volatile-bearing crystalline components. Here we report transmission XRD patterns for sulfate and silicate phases relevant to interpretation of MSL-CheMin XRD amorphous components.

  14. Quantified abundance of magnetofossils at the Paleocene-Eocene boundary from synchrotron-based transmission X-ray microscopy.

    Science.gov (United States)

    Wang, Huapei; Wang, Jun; Chen-Wiegart, Yu-Chen Karen; Kent, Dennis V

    2015-10-13

    The Paleocene-Eocene boundary (∼55.8 million years ago) is marked by an abrupt negative carbon isotope excursion (CIE) that coincides with an oxygen isotope decrease interpreted as the Paleocene-Eocene thermal maximum. Biogenic magnetite (Fe3O4) in the form of giant (micron-sized) spearhead-like and spindle-like magnetofossils, as well as nano-sized magnetotactic bacteria magnetosome chains, have been reported in clay-rich sediments in the New Jersey Atlantic Coastal Plain and were thought to account for the distinctive single-domain magnetic properties of these sediments. Uncalibrated strong field magnet extraction techniques have been typically used to provide material for scanning and transmission electron microscopic imaging of these magnetic particles, whose concentration in the natural sediment is thus difficult to quantify. In this study, we use a recently developed ultrahigh-resolution, synchrotron-based, full-field transmission X-ray microscope to study the iron-rich minerals within the clay sediment in their bulk state. We are able to estimate the total magnetization concentration of the giant biogenic magnetofossils to be only ∼10% of whole sediment. Along with previous rock magnetic studies on the CIE clay, we suggest that most of the magnetite in the clay occurs as isolated, near-equidimensional nanoparticles, a suggestion that points to a nonbiogenic origin, such as comet impact plume condensates in what may be very rapidly deposited CIE clays.

  15. Observations of celestial X-ray sources above 20 keV with the high-energy scintillation spectrometer on board OSO-8

    International Nuclear Information System (INIS)

    Crannell, C.J.; Dennis, B.R.; Dolan, J.F.; Frost, K.J.; Orwig, L.E.; Maurer, G.S.

    1977-01-01

    High-energy x-ray spectra of the Crab Nebula, Cyg XR-1, and Cen A have been determined from observations with the scintillation spectrometer on board the OSO-8 satellite, launched in June, 1975. Each of these sources was observed over two periods of 8 days or more, enabling a search for day-to-day and year-to-year variations in the spectral and temporal characteristics of the x-ray emission. No variation in the light curve of the Crab pulsar has been found from observations which span a 15-day period in March 1976, with demonstrable phase stability. Transitions associated with the binary phase of Cyg XR-1 and a large change in the emission from Cen A are reported

  16. X-ray optics and X-ray microscopes: new challenges

    International Nuclear Information System (INIS)

    Susini, J.

    2004-01-01

    main fields of applications are driven by the unique attributes of X-ray microscopy in the multi-keV energy range: i) access to K-absorption edges and fluorescence emission lines of medium-light elements and L,M - edges of heavy materials for micro-spectroscopy (e.g. XANES), chemical or trace element mapping ii) higher penetration depths compared to soft X-rays allowing imaging of thicker samples, iii) favorable wavelengths for diffraction studies and iv) generally large focal lengths and depths of focus which are advantageous for the use of specific sample environments (high pressure, controlled temperatures....). Typical experiments can be broadly divided into two categories: i) morphological studies which require high spatial resolution and are therefore well adapted to 2D or 3D transmission full-field microscopy. ii) studies dealing with co-localization and/or speciation of trace elements in heterogeneous matrices at the micron scale. Following a brief account on the basic principles and methods, strengths and weaknesses of X-ray microscopy and spectro-microscopy techniques in the 1 - 30 keV range will be discussed and illustrated by examples of applications. The main technical developments, involving new focusing lenses or novel phase contrast geometry, will be presented. (author)

  17. Fabrication and characterization of free-standing, high-line-density transmission gratings for the vacuum UV to soft X-ray range

    NARCIS (Netherlands)

    Goh, S.J.; Bastiaens, Hubertus M.J.; Vratzov, B.; Huang, Qiushi; Bijkerk, Frederik; Boller, Klaus J.

    2015-01-01

    We present state-of-the-art high resolution transmission gratings, applicable for spectroscopy in the vacuum ultraviolet (VUV) and the soft X-ray (SRX) wavelength range, fabricated with a novel process using ultraviolet based nano imprint lithography (UV-NIL). Free-standing, high-line-density

  18. Characterization by Raman scattering, x-ray diffraction, and transmission electron microscopy of (AlAs)m(InAs)m short period superlattices grown by migration enhanced epitaxy

    DEFF Research Database (Denmark)

    Bradshaw, J.; Song, X.J.; Shealy, J.R.

    1992-01-01

    We report growth of (InAs)1(AlAs)1 and (InAs)2(AlAs)2 strained layer superlattices by migration enhanced epitaxy. The samples were grown on InP (001) substrates and characterized by Raman spectroscopy, x-ray diffraction, and transmission electron microscopy. Satellite peaks in the x-ray data...... confirm the intended periodicity and indicate the presence of some disorder in the monolayer sample. The energies of the zone folded and quantum confined optic phonons are in reasonable agreement with calculations based on one-dimensional elastic continuum and linear chain models. Journal of Applied...

  19. Analytical electron microscope based on scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy to realize highly sensitive elemental imaging especially for light elements

    International Nuclear Information System (INIS)

    Koguchi, Masanari; Tsuneta, Ruriko; Anan, Yoshihiro; Nakamae, Koji

    2017-01-01

    An analytical electron microscope based on the scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy (STEM-WDX) to realize highly sensitive elemental imaging especially for light elements has been developed. In this study, a large-solid-angle multi-capillary x-rays lens with a focal length of 5 mm, long-time data acquisition (e.g. longer than 26 h), and a drift-free system made it possible to visualize boron-dopant images in a Si substrate at a detection limit of 0.2 atomic percent. (paper)

  20. An expert system for the conception of industrial gauges based on beta, gamma or X ray transmission (JANU)

    International Nuclear Information System (INIS)

    Tola, F.

    2000-01-01

    A knowledge based software (named JANU expert system) for radiogauges design mainly density, thickness, mass per unit area, level and two-phase flows gauges, was prepared recently. Its aim is to optimise the different components of a transmission gauge (radioactive source, detector, electronic device, collimators and shielding), taking into account parameters and constraints linked to the configuration (nature and composition of materials, presence of shields and walls, ...), as well as users requirements (accuracy, counting time, beam collimating, duration of tests, ...). The database includes characteristics of radionuclides and industrial sources, photon cross sections, build-up factors, specific dose constants, physical properties of elements, usual scintillation detectors and shielding materials. It allows the determination of the most suited emitter, as well as a precise characterisation of a given emitter, including required source activity, expected counting rates, dose rates, etc. It has been extended to X rays generators, voltage and current intensity replacing in this case the energy and activity of the source. Information supplied by JANU has been validated by applications developed during the past 30 years. Its choices have always revealed most judicious and in general, numerical results in good agreement with experiments. Thus, it has become an essential and reliable tool for gauge designers. (author)

  1. A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

    International Nuclear Information System (INIS)

    Kilcoyne, David; Ade, Harald; Attwood, David; Hitchcock, Adam; McKean, Pat; Mitchell, Gary; Monteiro, Paulo; Tyliszczak, Tolek; Warwick, Tony

    2010-01-01

    We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

  2. Smectite flocculation structure modified by Al13 macro-molecules--as revealed by the transmission X-ray microscopy (TXM).

    Science.gov (United States)

    Zbik, Marek S; Martens, Wayde N; Frost, Ray L; Song, Yen-Fang; Chen, Yi-Ming; Chen, Jian-Hua

    2010-05-01

    The aggregate structure which occurs in aqueous smectitic suspensions is responsible for poor water clarification, difficulties in sludge dewatering and the unusual rheological behaviour of smectite rich soils. These macroscopic properties are dictated by the 3D structural arrangement of smectite finest fraction within flocculated aggregates. Here, we report results from a relatively new technique, transmission X-ray microscopy (TXM), which makes it possible to investigate the internal structure and 3D tomographic reconstruction of the smectite clay aggregates modified by Al(13) Keggin macro-molecule [Al(13)(O)(4)(OH)(24)(H(2)O)(12)](7+). Three different treatment methods were shown resulted in three different micro-structural environments of the resulting flocculation. In case of smectite sample prepared in Methods 1 and 3 particles fall into the primary minimum where Van der Waals forces act between FF oriented smectite flakes and aggregates become approach irreversible flocculation. In case of sample prepared using Method 2, particles contacting by edges (EE) and edge to face (EF) orientation fell into secondary minimum and weak flocculation resulted in severe gelation and formation of the micelle-like texture in fringe superstructure, which was first time observed in smectite based gel. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Real-time X-ray transmission microscopy for fundamental studies solidification: Al-Al2Au eutectic

    International Nuclear Information System (INIS)

    Curreri, Peter A.; Kaukler, William F.; Sen, Subhayu

    1998-01-01

    High resolution real-time X-ray Transmission Microscopy, XTM, has been applied to obtain information fundamental to solidification of optically opaque metallic systems. We have previously reported the measurement of the solute profile in the liquid, phase growth, and detailed solid-liquid interfacial morphology of aluminum based alloys with exposure times less than 2 seconds. Recent advances in XTM furnace design have provided an increase in real-time magnification (during solidification) for the XTM from 40X to 160X. The increased magnification has enabled for the first time the XTM imaging of real-time growth of fibers and particles with diameters of 5 μm. We have previously applied this system to study the kinetics of formation and morphological evolution of secondary fibers and particles in Al-Bi monotectic alloys. In this paper we present the preliminary results of the first real-time observations of fiber morphology evolution in optically opaque bulk metal sample of Aluminum-Gold eutectic alloy. These studies show that the XTM can be applied to study the fundamentals of eutectic and monotectic solidification. We are currently attempting to apply this technology in the fundamentals of solidification in microgravity

  4. Transmission X-Ray Microscopy of the Galvanostatic Growth of Lead Sulfate on Lead: Impact of Lignosulfonate

    International Nuclear Information System (INIS)

    Knehr, K.W.; Eng, Christopher; Wang, Jun; West, Alan C.

    2015-01-01

    The galvanostatic growth of PbSO 4 on Pb in H 2 SO 4 was studied using scanning electron microscopy and in situ transmission X-ray microscopy (TXM). Images from the TXM are used to investigate the effects of sodium lignosulfonate on the PbSO 4 formation and the initial growth of the PbSO 4 crystals. Sodium lignosulfonate is shown to retard, on average, the growth of the PbSO 4 crystals, yielding a film with smaller crystals and higher crystal densities. In addition, results from experiments with and without sodium lignosulfonate indicate an increase in the nucleation rate of the PbSO 4 crystals when the oxidation current is applied, which was attributed to an increase in the supersaturation of the electrolyte. Furthermore, an analysis of the growth rates of individual, large crystals showed an initial rapid growth which declined as the PbSO 4 surface coverage increased. It was concluded that the increase in PbSO 4 provides additional sites for precipitation and reduces the precipitation rate on the existing crystals. Finally, the potential-time transient at the beginning of oxidation is suggested to result from the relaxation of a supersaturated solution and the development of a PbSO 4 film with increasing resistance

  5. Induced magnetic anisotropy in Si-free nanocrystalline soft magnetic materials: A transmission x-ray diffraction study

    International Nuclear Information System (INIS)

    Parsons, R.; Suzuki, K.; Yanai, T.; Kishimoto, H.; Kato, A.; Ohnuma, M.

    2015-01-01

    In order to better understand the origin of field-induced anisotropy (K u ) in Si-free nanocrystalline soft magnetic alloys, the lattice spacing of the bcc-Fe phase in nanocrystalline Fe 94−x Nb 6 B x (x = 10, 12, 14) alloys annealed under an applied magnetic field has been investigated by X-ray diffraction in transmission geometry (t-XRD) with the diffraction vector parallel and perpendicular to the field direction. The saturation magnetostriction (λ s ) of nanocrystalline Fe 94−x Nb 6 B x was found to increase linearly with the volume fraction of the residual amorphous phase and is well described by taking into account the volume-weighted average of two local λ s values for the bcc-Fe nanocrystallites (−5 ± 2 ppm) and the residual amorphous matrix (+8 ± 2 ppm). The lattice distortion required to produce the measured K u values (∼100 J/m 3 ) was estimated via the inverse magnetostrictive effect using the measured λ s values and was compared to the lattice spacing estimations made by t-XRD. The lattice strain required to produce K u under the magnetoelastic model was not observed by the t-XRD experiments and so the findings of this study suggest that the origin of magnetic field induced K u cannot be explained through the magnetoelastic effect

  6. Classification of Multiple Types of Organic Carbon Composition in Atmospheric Particles by Scanning Transmission X-Ray Microscopy Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kilcoyne, Arthur L; Takahama, S.; Gilardoni, S.; Russell, L.M.; Kilcoyne, A.L.D.

    2007-05-16

    A scanning transmission X-ray microscope at the Lawrence Berkeley National Laboratory is used to measure organic functional group abundance and morphology of atmospheric aerosols. We present a summary of spectra, sizes, and shapes observed in 595 particles that were collected and analyzed between 2000 and 2006. These particles ranged between 0.1 and 12 mm and represent aerosols found in a large range of geographical areas, altitudes, and times. They include samples from seven different field campaigns: PELTI, ACE-ASIA, DYCOMS II, Princeton, MILAGRO (urban), MILAGRO (C-130), and INTEX-B. At least 14 different classes of organic particles show different types of spectroscopic signatures. Different particle types are found within the same region while the same particle types are also found in different geographical domains. Particles chemically resembling black carbon, humic-like aerosols, pine ultisol, and secondary or processed aerosol have been identified from functional group abundance and comparison of spectra with those published in the literature.

  7. Charge state mapping of mixed valent iron and manganese mineral particles using Scanning Transmission X-ray Microscopy (STXM)

    International Nuclear Information System (INIS)

    Pecher, K.; Nealson, K.; Kneedler, E.; Rothe, J.; Meigs, G.; Warwick, T.; Tonner, B.

    2000-01-01

    The interfaces between solid mineral particles and water play a crucial role in partitioning and chemical transformation of many inorganic as well as organic pollutants in environmental systems. Among environmentally significant minerals, mixed-valent oxides and hydroxides of iron (e.g. magnetite, green rusts) and manganese (hausmanite, birnessite) have been recognized as particularly strong sorbents for metal ions. In addition, minerals containing Fe(II) have recently been proven to be powerful reductants for a wide range of pollutants. Chemical properties of these minerals strongly depend on the distribution and availability of reactive sites and little is known quantitatively about the nature of these sites. We have investigated the bulk distribution of charge states of manganese (Mn (II, III, IV)) and iron (Fe(II, III)) in single particles of natural manganese nodules and synthetic green rusts using Scanning Transmission X-ray SpectroMicroscopy (STXM). Pixel resolved spectra (XANES) extracted from stacks of images taken at different wave lengths across the metal absorption edge were fitted to total electron yield (TEY) spectra of single valent reference compounds. Two dimensional maps of bulk charge state distributions clearly reveal domains of different oxidation states within single particles of Mn-nodules and green rust precipitates. Changes of oxidation states of iron were followed as a result of reductive transformation of an environmental contaminant (CCl 4 ) using green rust as the only reductant

  8. Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Wilson Roberto Dejato da

    2005-07-01

    In this work, the gamma rays transmission and X-rays microtomography techniques are used for the evaluation of the porosity and the pore size distribution of SiC ceramic foams. It was also accomplished the three-dimensional images after the determination of samples geometric parameters. The geometric parameters were obtained by two-dimensional images analyses, generated by a Microfocus system, with a CCD camera, an images intensifier, a X-rays tube and an automatic system for rotation of the sample. The spatial resolution of the images was about 32 {mu}m. In the gamma rays transmission methodology, a Nal(Tl) scintillation detector, an {sup 241}Am (59.53 keV, 100 mCi) radioactive source and an automatic X-Z micrometric table was used. The analyzed samples had pores density of 30, 45, 60, 80 and 100 ppi (pores per inch). The gamma rays transmission technique was accurate to supply the porosity of the samples, which ranged about 90% and was in agreement with the values supplied by manufacturer of the foams. The 30 and 45 ppi samples analyzed by X-rays microtomography showed porosity results that agree with the average porosity supplied by the manufacturer. In other hand, the 60, 80 and 100 ppi samples systematically showed average porosity about 4%, lower than the average of the manufacturer. The pore size distributions found through the software IMAGO show the presence of smaller pores than those nominated by the manufacturer. The 30 ppi samples had voids inside the solid material of the ceramic foams structure. Gaussian truncated method, used in the three-dimensional reconstruction, was not able to take into the account the voids inside the solid matrix. (author)

  9. Radiation transmission of heavyweight and normal-weight concretes containing colemanite for 6 MV and 18 MV X-rays using linear accelerator

    International Nuclear Information System (INIS)

    Demir, F.; Budak, G.; Sahin, R.; Karabulut, A.; Oltulu, M.; Serifoglu, K.; Un, A.

    2010-01-01

    Accurate measurements have been made to determine radiation transmission of concretes produced with barite, colemanite and normal aggregate by using beam transmission method for 6 and 18 MV X-rays with a linear accelerator (LINAC). Linear attenuation coefficients of thirteen heavy- and four normal-weight concretes were calculated. It was determined that linear attenuation coefficient (μ, cm -1 ) decreased with colemanite concentration and increased with barite concentration in both types of the concretes.

  10. Structure-Property Relationships in Aluminum-Copper alloys using Transmission X-Ray Microscopy (TXM) and Micromechanical Testing

    Science.gov (United States)

    Kaira, Chandrashekara Shashank

    that effect, in situ tests were conducted at the synchrotron (Advanced Photon Source) using Transmission X-Ray Microscopy as well as in a scanning electron microscope (SEM) to study real-time damage evolution in such alloys. Findings of precipitate size-dependent transition in deformation behavior from these tests have inspired a novel resilient aluminum alloy design.

  11. Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser

    Czech Academy of Sciences Publication Activity Database

    Andreasson, J.; Iwan, B.; Andrejczuk, A.; Abreu, E.; Bergh, M.; Caleman, C.; Nelson, A.J.; Bajt, S.; Chalupský, Jaromír; Chapman, H.N.; Fäustlin, R.R.; Hájková, Věra; Heimann, P.A.; Hjörvarsson, B.; Juha, Libor; Klinger, D.; Krzywinski, J.; Nagler, B.; Pálsson, G.K.; Singer, W.; Seibert, M.M.; Sobierajski, R.; Toleikis, S.; Tschentscher, T.; Vinko, S.M.; Lee Seung-Soo, S.; Hajdu, J.; Timneanu, N.

    2011-01-01

    Roč. 83, č. 1 (2011), "016403-1"-"016403-7" ISSN 1539-3755 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAAX00100903; GA MŠk(CZ) ME10046 Institutional research plan: CEZ:AV0Z10100523 Keywords : X-ray laser * XUV laser * warm dense matter * ion emission Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.255, year: 2011

  12. Beryllium parabolic refractive x-ray lenses

    International Nuclear Information System (INIS)

    Lengeler, B.; Schroer, C.G.; Kuhlmann, M.; Benner, B.; Guenzler, T.F.; Kurapova, O.; Somogyi, A.; Snigirev, A.; Snigireva, I.

    2004-01-01

    Parabolic refractive x-ray lenses are novel optical components for the hard x-ray range from about 5 keV to about 120 keV. They focus in both directions. They are compact, robust, and easy to align and to operate. They can be used like glass lenses are used for visible light, the main difference being that the numerical aperture N.A. is much smaller than 1 (of order 10-4 to 10-3). Their main applications are in micro- and nanofocusing, in imaging by absorption and phase contrast and in fluorescence mode. In combination with tomography they allow for 3-dimensional imaging of opaque media with submicrometer resolution. Finally, they can be used in speckle spectroscopy by means of coherent x-ray scattering. Beryllium as lens material strongly enhances the transmission and the field of view as compared to aluminium. With increased N.A. the lateral resolution is also considerably improved with Be lenses. References to a number of applications are given

  13. A low power x-ray tube for use in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kataria, S.K.; Govil, Rekha; Lal, M.

    1980-01-01

    A low power X-ray tube with thin molybdenum transmission target for use in energy dispersive X-ray fluorescence (ENDXRF) element analysis has been indigenously built, along with its power supply. The X-ray tube has been in operation since August 1979, and it has been operated upto maximum target voltage of 35 KV and tube current upto 200 μA which is more than sufficient for trace element analysis. This X-ray tube has been used alongwith the indigenously built Si(Li) detector X-ray spectrometer with an energy resolution of 200 eV at 5.9 Kev MnKsub(α) X-ray peak for ENDXRF analysis. A simple procedure of calibration has been developed for thin samples based on the cellulose diluted, thin multielement standard pellets. Analytical sensitivities of the order of a few p.p.m. have been obtained with the experimental setup for elements with 20 < = Z < = 38 and 60 < = Z < = 90. A number of X-ray spectra for samples of environmental, biological, agricultural, industrial and metallurgical interest are presented to demonstrate the salient features of the experimental sep up. (auth.)

  14. Microfocussing of synchrotron X-rays using X-ray refractive lens

    Indian Academy of Sciences (India)

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance ...

  15. Nanoscale X-Ray Microscopic Imaging of Mammalian Mineralized Tissue

    OpenAIRE

    Andrews, Joy C.; Almeida, Eduardo; van der Meulen, Marjolein C.H.; Alwood, Joshua S.; Lee, Chialing; Liu, Yijin; Chen, Jie; Meirer, Florian; Feser, Michael; Gelb, Jeff; Rudati, Juana; Tkachuk, Andrei; Yun, Wenbing; Pianetta, Piero

    2010-01-01

    A novel hard transmission X-ray microscope (TXM) at the Stanford Synchrotron Radiation Light-source operating from 5 to 15 keV X-ray energy with 14 to 30 µm2 field of view has been used for high-resolution (30–40 nm) imaging and density quantification of mineralized tissue. TXM is uniquely suited for imaging of internal cellular structures and networks in mammalian mineralized tissues using relatively thick (50 µm), untreated samples that preserve tissue micro- and nanostructure. To test this...

  16. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  17. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  18. Preparation of biological samples for transmission X-ray microanalysis: a review of alternative procedures to the use of sectioned material

    International Nuclear Information System (INIS)

    Sigee, D.C.

    1988-01-01

    Although transmission X-ray microanalysis of biological material has traditionally been carried out mainly on sectioned preparations, a number of alternative procedures exist. These are considered under three major headings - whole cell preparations, analysis of cell homogenates and biological fluids, and applications of the technique to microsamples of purified biochemicals. These three aspects provide a continuous range of investigative level - from the cellular to the molecular. The use of X-ray microanalysis with whole cell preparations is considered in reference to eukaryote (animal) cells and prokaryotes - where it has particular potential in environmental studies on bacteria. In the case of cell homogenates and biological fluids, the technique has been used mainly with microdroplets of animal material. The use of X-ray microanalysis with purified biochemicals is considered in relation to both particulate and non-particulate samples. In the latter category, the application of this technique for analysis of thin films of metalloprotein is particularly emphasised. It is concluded that wider use could be made of the range of preparative techniques available - both within a particular investigation, and in diverse fields of study. Transmission X-ray microanalysis has implications for environmental, physiological and molecular biology as well as cell biology

  19. New Constraints on the Geometry and Kinematics of Matter Surrounding the Accretion Flow in X-Ray Binaries from Chandra High-energy Transmission Grating X-Ray Spectroscopy

    Science.gov (United States)

    Tzanavaris, P.; Yaqoob, T.

    2018-03-01

    The narrow, neutral Fe Kα fluorescence emission line in X-ray binaries (XRBs) is a powerful probe of the geometry, kinematics, and Fe abundance of matter around the accretion flow. In a recent study it has been claimed, using Chandra High-Energy Transmission Grating (HETG) spectra for a sample of XRBs, that the circumnuclear material is consistent with a solar-abundance, uniform, spherical distribution. It was also claimed that the Fe Kα line was unresolved in all cases by the HETG. However, these conclusions were based on ad hoc models that did not attempt to relate the global column density to the Fe Kα line emission. We revisit the sample and test a self-consistent model of a uniform, spherical X-ray reprocessor against HETG spectra from 56 observations of 14 Galactic XRBs. We find that the model is ruled out in 13/14 sources because a variable Fe abundance is required. In two sources a spherical distribution is viable, but with nonsolar Fe abundance. We also applied a solar-abundance Compton-thick reflection model, which can account for the spectra that are inconsistent with a spherical model, but spectra with a broader bandpass are required to better constrain model parameters. We also robustly measured the velocity width of the Fe Kα line and found FWHM values of up to ∼5000 km s‑1. Only in some spectra was the Fe Kα line unresolved by the HETG.

  20. New Constraints on the Geometry and Kinematics of Matter Surrounding the Accretion Flow in X-Ray Binaries from Chandra High-Energy Transmission Grating X-Ray Spectroscopy

    Science.gov (United States)

    Tzanavaris, P.; Yaqoob, T.

    2018-01-01

    The narrow, neutral Fe Ka fluorescence emission line in X-ray binaries (XRBs) is a powerful probe of the geometry, kinematics, and Fe abundance of matter around the accretion flow. In a recent study it has been claimed, using Chandra High-Energy Transmission Grating (HETG) spectra for a sample of XRBs, that the circumnuclear material is consistent with a solar-abundance, uniform, spherical distribution. It was also claimed that the Fe Ka line was unresolved in all cases by the HETG. However, these conclusions were based on ad hoc models that did not attempt to relate the global column density to the Fe Ka line emission. We revisit the sample and test a self-consistent model of a uniform, spherical X-ray reprocessor against HETG spectra from 56 observations of 14 Galactic XRBs. We find that the model is ruled out in 13/14 sources because a variable Fe abundance is required. In two sources a spherical distribution is viable, but with nonsolar Fe abundance. We also applied a solar-abundance Compton-thick reflection model, which can account for the spectra that are inconsistent with a spherical model, but spectra with a broader bandpass are required to better constrain model parameters. We also robustly measured the velocity width of the Fe Ka line and found FWHM values of up to approx. 5000 km/s. Only in some spectra was the Fe Ka line unresolved by the HETG.

  1. DIELECTRICALLY-LOADED WAVEGUIDE AS A MICROWAVE UNDULATOR FOR HIGH BRILLANCE X-RAYS AT 45 – 90 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Kustom, R. L.; Waldschmidt, G.; Nassiri, A.

    2017-06-01

    The HEM12 mode in a cylindrical, dielectrically-loaded waveguide provides E and H fields on the central axis that are significantly higher than the fields on the conducting walls. This structure, operating near the cutoff frequency of the HEM12 mode, spans a frequency range where the wavelength and phase velocity vary significantly. This property can be exploited to generate undulator action with short periods for the generation of high brightness xrays. The frequency range of interest would be from 18 to 34.5-GHz. The goal would be to generate x-rays on the fundamental mode over a range of 45 to 90-keV.The tunability would be achieved by changing the source frequency while maintaining a constant on-axis equivalent undulator field strength of 0.5-T.

  2. 3.5 keV X-ray line signal from dark matter decay in local U(1){sub B−L} extension of Zee-Babu model

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seungwon [School of Physics and Open KIAS Center, KIAS,85 Hoegiro Dongdaemun-gu, Seoul 130-722 (Korea, Republic of)

    2015-08-06

    We consider a local U(1){sub B−L} extension of Zee-Babu model to explain the recently observed 3.5 keV X-ray line signal. The model has three Standard model (SM)-singlet Dirac fermions with different U(1){sub B−L} charges. A complex scalar field charged under U(1){sub B−L} is introduced to break the U(1){sub B−L} symmetry. After U(1){sub B−L} symmetry breaking a remnant discrete symmetry stabilizes the lightest state of the Dirac fermions, which can be a stable dark matter (DM). The second lightest state, if mass splitting with the stable DM is about 3.5 keV, decays dominantly to the stable DM and 3.5 keV photon through two-loop diagrams, explaining the X-ray line signal. Two-loop suppression of the decay amplitude makes its lifetime much longer than the age of the universe and it can be a decaying DM candidate in large parameter region. We also introduce a real scalar field which is singlet under both the SM and U(1){sub B−L} and can explain the current relic abundance of the Dirac fermionic DMs. If the mixing with the SM Higgs boson is small, it does not contribute to DM direct detection. The main contribution to the scattering of DM off atomic nuclei comes from the exchange of U(1){sub B−L} gauge boson, Z{sup ′}, and is suppressed below current experimental bound when Z{sup ′} mass is heavy (≳10 TeV). If the singlet scalar mass is about 0.1–10 MeV, DM self-interaction can be large enough to solve small scale structure problems in simulations with the cold DM, such as, the core-vs-cusp problem and too-big-to-fail problem.

  3. Induced magnetic anisotropy in Si-free nanocrystalline soft magnetic materials: A transmission x-ray diffraction study

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, R., E-mail: rparsons01@gmail.com; Suzuki, K. [Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800 (Australia); Yanai, T. [Graduate School of Engineering, Nagasaki University, Nagasaki 852-8521 (Japan); Kishimoto, H.; Kato, A. [Toyota Motor Corporation, Mishuku, Susono, Shizuoka 410-1193 (Japan); Ohnuma, M. [Faculty and Graduate School of Engineering, Hokkaido University, Sapporo 060-8628 (Japan)

    2015-05-07

    In order to better understand the origin of field-induced anisotropy (K{sub u}) in Si-free nanocrystalline soft magnetic alloys, the lattice spacing of the bcc-Fe phase in nanocrystalline Fe{sub 94−x}Nb{sub 6}B{sub x} (x = 10, 12, 14) alloys annealed under an applied magnetic field has been investigated by X-ray diffraction in transmission geometry (t-XRD) with the diffraction vector parallel and perpendicular to the field direction. The saturation magnetostriction (λ{sub s}) of nanocrystalline Fe{sub 94−x}Nb{sub 6}B{sub x} was found to increase linearly with the volume fraction of the residual amorphous phase and is well described by taking into account the volume-weighted average of two local λ{sub s} values for the bcc-Fe nanocrystallites (−5 ± 2 ppm) and the residual amorphous matrix (+8 ± 2 ppm). The lattice distortion required to produce the measured K{sub u} values (∼100 J/m{sup 3}) was estimated via the inverse magnetostrictive effect using the measured λ{sub s} values and was compared to the lattice spacing estimations made by t-XRD. The lattice strain required to produce K{sub u} under the magnetoelastic model was not observed by the t-XRD experiments and so the findings of this study suggest that the origin of magnetic field induced K{sub u} cannot be explained through the magnetoelastic effect.

  4. Atomic level study of water-gas shift catalysts via transmission electron microscopy and x-ray spectroscopy

    Science.gov (United States)

    Akatay, Mehmed Cem

    Water-gas shift (WGS), CO + H2O ⇆ CO2 + H2 (DeltaH° = -41 kJ mol -1), is an industrially important reaction for the production of high purity hydrogen. Commercial Cu/ZnO/Al2O3 catalysts are employed to accelerate this reaction, yet these catalysts suffer from certain drawbacks, including costly regeneration processes and sulfur poisoning. Extensive research is focused on developing new catalysts to replace the current technology. Supported noble metals stand out as promising candidates, yet comprise intricate nanostructures complicating the understanding of their working mechanism. In this study, the structure of the supported Pt catalysts is explored by transmission electron microscopy and X-ray spectroscopy. The effect of the supporting phase and the use of secondary metals on the reaction kinetics is investigated. Structural heterogeneities are quantified and correlated with the kinetic descriptors of the catalysts to develop a fundamental understanding of the catalytic mechanism. The effect of the reaction environment on catalyst structure is examined by in-situ techniques. This study benefitted greatly from the use of model catalysts that provide a convenient medium for the atomic level characterization of nanostructures. Based on these studies, Pt supported on iron oxide nano islands deposited on inert spherical alumina exhibited 48 times higher WGS turnover rate (normalized by the total Pt surface area) than Pt supported on bulk iron oxide. The rate of aqueous phase glycerol reforming reaction of Pt supported on multiwall carbon nanotubes (MWCNT) is promoted by co-impregnating with cobalt. The synthesis resulted in a variety of nanostructures among which Pt-Co bimetallic nanoparticles are found to be responsible for the observed promotion. The unprecedented WGS rate of Pt supported on Mo2C is explored by forming Mo 2C patches on top of MWCNTs and the rate promotion is found to be caused by the Pt-Mo bimetallic entities.

  5. X-ray imaging with compound refractive lens and microfocus X-ray tube

    OpenAIRE

    Pina, Ladislav; Dudchik, Yury; Jelinek, Vaclav; Sveda, Libor; Marsik, Jiri; Horvath, Martin; Petr, Ondrej

    2008-01-01

    Compound refractive lenses (CRL), consisting of a lot number in-line concave microlenses made of low-Z material were studied. Lenses with focal length 109 mm and 41 mm for 8-keV X-rays, microfocus X-ray tube and X-ray CCD camera were used in experiments. Obtained images show intensity distribution of magnified microfocus X-ray source focal spot. Within the experiments, one lens was also used as an objective lens of the X-ray microscope, where the copper anode X-ray microfocus tube served as a...

  6. Detailed tabulation of atomic form factors, photoelectric absorption and scattering cross section, and mass attenuation coefficients in the vicinity of absorption edges in the soft X-ray (Z=30-36, Z=60-89, E=0.1 keV-10 keV), addressing convergence issues of earlier work

    International Nuclear Information System (INIS)

    Chantler, C.T.

    2000-01-01

    Reliable knowledge of the complex x-ray form factor [Re(f ) ] and the photoelectric attenuation coefficient (σ PE ) is required for crystallography, medical diagnosis, radiation safety, and XAFS studies. Discrepancies between currently used theoretical approaches of 200% exist for numerous elements from 1 to 3 keV x-ray energies. The key discrepancies are due to the smoothing of edge structure, the use of nonrelativistic wave functions, and the lack of appropriate convergence of wave functions. This paper addresses these key discrepancies and derives new theoretical results of substantially higher accuracy in near-edge soft x-ray regions. The high-energy limitations of the current approach are also illustrated. The energy range covered is 0.1 to 10 keV. The associated figures and tabulation demonstrate the current comparison with alternate theory and with available experimental data. In general, experimental data are not sufficiently accurate to establish the errors and inadequacies of theory at this level. However, the best experimental data and the observed experimental structure as a function of energy are strong indicators of the validity of the current approach. New developments in experimental measurement hold great promise in making critical comparisons with theory in the near future

  7. Detailed new tabulation of atomic form factors and attenuation coefficients in the near-edge soft x-ray regime (Z = 30-36, Z = 60-89, E 0.1 keV - 8 keV), addressing convergence issues of earlier work

    International Nuclear Information System (INIS)

    Chantler, C.T.

    1998-01-01

    Reliable knowledge of the complex X-ray form factor (Re(f) and f ) and the photoelectric attenuation coefficient σ PE is required for crystallography, medical diagnosis, radiation safety and XAFS studies. Discrepancies between currently used theoretical approaches of 200% exist for numerous elements from 1 keV to 3 keV X-ray energies. The key discrepancies are due to the smoothing of edge structure, the use of non-relativistic wavefunctions, and the lack of appropriate convergence of wavefunctions. This paper addresses these key discrepancies and derives new theoretical results of substantially higher accuracy in near-edge soft X-ray regions. The high-energy limitations of the current approach are also illustrated. The associated figures and tabulation demonstrate the current comparison with alternate theory and with available experimental data. In general, experimental data is not sufficiently accurate to establish the errors and inadequacies of theory at this level. However, the best experimental data and the observed experimental structure as a function of energy are strong indicators of the validity of the current approach. New developments in experimental measurement hold great promise in making critical comparisons with theory in the near future. (authors)

  8. Li (i = 1-3) subshell X-ray production cross sections and fluorescence yields for some elements with 56 ≤ Z ≤ 68 at 22.6 keV

    International Nuclear Information System (INIS)

    Chauhan, Yogeshwar; Tiwari, M.K.; Puri, Sanjiv

    2008-01-01

    The L k (k = l, α, β 1,4 , β 3,6 , β 2,15,9,10,7 , γ 1,5 and γ 2,3,4 ) X-ray production (XRP) cross sections have been measured for six elements with 56 ≤ Z ≤ 68 at 22.6 keV incident photon energy using the EDXRF spectrometer. The incident photon intensity, detector efficiency and geometrical factors have been determined from the K X-ray yields emitted from elemental targets with 22 ≤ Z ≤ 42 in the same geometrical setup and from knowledge of the K XRP cross sections. The L 1 and L 2 subshell fluorescence yields have been deduced from the present measured L k XRP cross sections using the relativistic Hartree-Fock-Slater (HFS) model based photoionization cross sections. The present deduced ω 1 (exp) values have been found to be, on an average, higher by 15% and 20% than those based on the Dirac-Hartree-Slater (DHS) model and the semi-empirical values compiled by Krause, respectively, for elements with 60 ≤ Z ≤ 68

  9. Fluorescent x-ray computed tomography to visualize specific material distribution

    Science.gov (United States)

    Takeda, Tohoru; Yuasa, Tetsuya; Hoshino, Atsunori; Akiba, Masahiro; Uchida, Akira; Kazama, Masahiro; Hyodo, Kazuyuki; Dilmanian, F. Avraham; Akatsuka, Takao; Itai, Yuji

    1997-10-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT systems consists of a silicon channel cut monochromator, an x-ray slit and a collimator for detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the K(alpha) line, incident monochromatic x-ray was set at 37 keV. At 37 keV Monte Carlo simulation showed almost complete separation between Compton scattering and the K(alpha) line. Actual experiments revealed small contamination of Compton scattering on the K(alpha) line. A clear FXCT image of a phantom was obtained. Using this system the minimal detectable dose of iodine was 30 ng in a volume of 1 mm3, and a linear relationship was demonstrated between photon counts of fluorescent x-rays and the concentration of iodine contrast material. The use of high incident x-ray energy allows an increase in the signal to noise ratio by reducing the Compton scattering on the K(alpha) line.

  10. Mass attenuation coefficients in the range 3.8⩽E⩽11 keV, K fluorescence yield and Kβ/Kα relative X-ray emission rate for Ti, V, Fe, Co, Ni, Cu and Zn measured with a tunable monochromatic X-ray source

    Science.gov (United States)

    Ménesguen, Y.; Lépy, M.-C.

    2010-08-01

    This work presents new measurements of mass attenuation coefficients in the range 3.8⩽E⩽11 keV, K-absorption jump-ratios, Kα and Kβ fluorescence yields for Ti, V, Fe, Co, Ni, Cu and Zn. We use the experimental facility SOLEX, a tunable monochromatic X-ray source combined with an energy-dispersive high-purity germanium detector. The results are compared with theoretical values as well as with other experimental data and show a relatively good agreement. However, the derived K-jump-ratios appear larger than those widely used in the XCOM database. The Kα and Kβ fluorescence yields and the corresponding relative emission rates Kβ/Kα are also derived, which was made possible by the use of energy-dispersive detectors with good spectral resolution.

  11. Image and diagnosis quality of X-ray image transmission via cell phone camera: a project study evaluating quality and reliability.

    Directory of Open Access Journals (Sweden)

    Hans Goost

    Full Text Available INTRODUCTION: Developments in telemedicine have not produced any relevant benefits for orthopedics and trauma surgery to date. For the present project study, several parameters were examined during assessment of x-ray images, which had been photographed and transmitted via cell phone. MATERIALS AND METHODS: A total of 100 x-ray images of various body regions were photographed with a Nokia cell phone and transmitted via email or MMS. Next, the transmitted photographs were reviewed on a laptop computer by five medical specialists and assessed regarding quality and diagnosis. RESULTS: Due to their poor quality, the transmitted MMS images could not be evaluated and this path of transmission was therefore excluded. Mean size of transmitted x-ray email images was 394 kB (range: 265-590 kB, SD ± 59, average transmission time was 3.29 min ± 8 (CI 95%: 1.7-4.9. Applying a score from 1-10 (very poor - excellent, mean image quality was 5.8. In 83.2 ± 4% (mean value ± SD of cases (median 82; 80-89%, there was agreement between final diagnosis and assessment by the five medical experts who had received the images. However, there was a markedly low concurrence ratio in the thoracic area and in pediatric injuries. DISCUSSION: While the rate of accurate diagnosis and indication for surgery was high with a concurrence ratio of 83%, considerable differences existed between the assessed regions, with lowest values for thoracic images. Teleradiology is a cost-effective, rapid method which can be applied wherever wireless cell phone reception is available. In our opinion, this method is in principle suitable for clinical use, enabling the physician on duty to agree on appropriate measures with colleagues located elsewhere via x-ray image transmission on a cell phone.

  12. Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    Science.gov (United States)

    Buhr, H; Büermann, L; Gerlach, M; Krumrey, M; Rabus, H

    2012-12-21

    For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron storage ring BESSY II both the radiant power and the fraction of power deposited in dry air were measured using a cryogenic electrical substitution radiometer and a free air ionization chamber, respectively. The measured absorption coefficients were compared with state-of-the art calculations and showed an average deviation of 2% from calculations by Seltzer. However, they agree within 1% with data calculated earlier by Hubbell. In the course of this work, an improvement of the data analysis of a previous experimental determination of the mass energy-absorption coefficient of air in the range of 3 to 10 keV was found to be possible and corrected values of this preceding study are given.

  13. Miniature x-ray point source for alignment and calibration of x-ray optics

    International Nuclear Information System (INIS)

    Price, R.H.; Boyle, M.J.; Glaros, S.S.

    1977-01-01

    A miniature x-ray point source of high brightness similar to that of Rovinsky, et al. is described. One version of the x-ray source is used to align the x-ray optics on the Argus and Shiva laser systems. A second version is used to determine the spatial and spectral transmission functions of the x-ray optics. The spatial and spectral characteristics of the x-ray emission from the x-ray point source are described. The physical constraints including size, intensity and thermal limitations, and useful lifetime are discussed. The alignment and calibration techniques for various x-ray optics and detector combinations are described

  14. Structure formation in a mixed dark matter model with decaying sterile neutrino: the 3.5 keV X-ray line and the Galactic substructure

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Akira [Department of Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 Japan (Japan); Kamada, Ayuki, E-mail: harada@utap.phys.s.u-tokyo.ac.jp, E-mail: ayuki.kamada@ucr.edu [Kavli IPMU (WPI), University of Tokyo, 5-1-5 Kashiwa-no-ha, Kashiwa-shi, Chiba, 277-8583 Japan (Japan)

    2016-01-01

    We perform a set of cosmological simulations of structure formation in a mixed dark matter (MDM) model. Our model is motivated by the recently identified 3.5 keV X-ray line, which can be explained by the decay of non-resonantly produced sterile neutrinos accounting for 20–60% of the dark matter in the Universe. These non-resonantly produced sterile neutrinos have a sizable free-streaming length and hence behave effectively as warm dark matter (WDM). Assuming the rest of dark matter is composed of some cold dark matter (CDM) particles, we follow the coevolution of a mixed WDM plus CDM cosmology. Specifically, we consider the models with the warm component fraction of r{sub warm}=0.25 and 0.50. Our MDM models predict that the comoving Jeans length at the matter-radiation equality is close to that of the thermally produced warm dark matter model with particle mass m{sub WDM}=2.4 keV, but the suppression in the fluctuation power spectrum is weaker. We perform large N-body simulations to study the structure of non-linear dark halos in the MDM models. The abundance of substructure is significantly reduced in the MDM models, and hence the so-called small-scale crisis is mitigated. The cumulative maximum circular velocity function (CVF) of at least one halo in the MDM models is in good agreement with the CVFs of the observed satellites in the Milky Way and the Andromeda galaxy. We argue that the MDM models open an interesting possibility to reconcile the reported 3.5 keV line and the internal structure of galaxies.

  15. Electromigration in integrated circuit interconnects studied by X-ray microscopy

    CERN Document Server

    Schneider, G; Anderson, E; Bates, W; Salmassi, F; Nachimuthu, P; Pearson, A; Richardson, D; Hambach, D; Hoffmann, N; Hasse, W; Hoffmann, K

    2003-01-01

    To study mass transport phenomena in advanced microelectronic devices with X-rays requires penetration of dielectric and Si layers up to 30 mu m thick. X-ray imaging at 1.8 keV photon energy provides a high amplitude contrast between Cu or Al interconnects and dielectric layers and can penetrate through the required thickness. To perform X-ray microscopy at 1.8 keV, a new Ru/Si multilayer was designed for the transmission X-ray microscope XM-1 installed at the Advanced Light Source in Berkeley. The mass flow in a passivated Cu interconnect was studied at current densities up to 10 sup 7 A/cm sup 2. In addition, we demonstrated the high material contrast from different elements in integrated circuits with a resolution of about 40 nm.

  16. Electromigration in integrated circuit interconnects studied by X-ray microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, G. E-mail: gschnei1@gwdg.de; Denbeaux, G.; Anderson, E.; Bates, W.; Salmassi, F.; Nachimuthu, P.; Pearson, A.; Richardson, D.; Hambach, D.; Hoffmann, N.; Hasse, W.; Hoffmann, K

    2003-01-01

    To study mass transport phenomena in advanced microelectronic devices with X-rays requires penetration of dielectric and Si layers up to 30 {mu}m thick. X-ray imaging at 1.8 keV photon energy provides a high amplitude contrast between Cu or Al interconnects and dielectric layers and can penetrate through the required thickness. To perform X-ray microscopy at 1.8 keV, a new Ru/Si multilayer was designed for the transmission X-ray microscope XM-1 installed at the Advanced Light Source in Berkeley. The mass flow in a passivated Cu interconnect was studied at current densities up to 10{sup 7} A/cm{sup 2}. In addition, we demonstrated the high material contrast from different elements in integrated circuits with a resolution of about 40 nm.

  17. A planar parabolic refractive nickel lens for high-energy X-rays

    International Nuclear Information System (INIS)

    Andrejczuk, Andrzej; Nagamine, Masaru; Sakurai, Yoshiharu; Itou, Masayoshi

    2013-01-01

    A compound refractive nickel lens focusing 174 keV X-rays to 5 µm with a gain of 4 is presented. A compound refractive lens made of nickel and designed for focusing high-energy synchrotron X-rays is presented. The lens consists of 600 parabolic grooves and focuses X-rays in one plane only (planar lens). The lenses made and investigated by us earlier exhibited low transmission and irregularities in the focused beam profile. Since then, improvements in lens manufacturing technology have been made. The present lens gives an almost Gaussian profile and produces four times higher intensity at its maximum compared with the intensity of primary X-ray beams of 174 keV

  18. Comparison of contrast-to-noise ratios of transmission and dark-field signal in grating-based X-ray imaging for healthy murine lung tissue

    International Nuclear Information System (INIS)

    Schwab, Felix; Schleede, Simone; Hahn, Dieter

    2013-01-01

    Purpose: An experimental comparison of the contrast-to-noise ratio (CNR) between transmission and dark-field signals in grating-based X-ray imaging for ex-vivo murine lung tissue. Materials and Methods: Lungs from three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Background noise of transmission and dark-field signal was quantified by measuring the standard deviation in a region of interest (ROI) placed in a homogeneous area outside the specimen. Image contrast was quantified by measuring the signal range in rectangular ROIs placed in central and peripheral lung parenchyma. The relative contrast gain (RCG) of dark-field over transmission images was calculated as CNRDF / CNRT. Results: In all images, there was a trend for contrast-to-noise ratios of dark-field images (CNRDF) to be higher than for transmission images (CNRT) for all ROIs (median 61 vs. 38, p = 0.10), but the difference was statistically significant only for peripheral ROIs (61 vs. 32, p = 0.03). Median RCG was >1 for all ROIs (1.84). RCG values were significantly smaller for central ROIs than for peripheral ROIs (1.34 vs. 2.43, p = 0.03). Conclusion: The contrast-to-noise ratio of dark-field images compares more favorably to the contrast-to-noise ratio of transmission images for peripheral lung regions as compared to central regions. For any specific specimen, a calculation of the RCG allows comparing which X-ray modality (dark-field or transmission imaging) produces better contrast-to-noise characteristics in a well-defined ROI. (orig.)

  19. The 2-79 keV X-ray spectrum of the Circinus galaxy with NuSTAR, XMM-Newton, and Chandra: a fully Compton-thick active galactic nucleus

    International Nuclear Information System (INIS)

    Arévalo, P.; Bauer, F. E.; Puccetti, S.; Walton, D. J.; Fuerst, F.; Grefenstette, B. W.; Harrison, F. A.; Madsen, K. K.; Koss, M.; Boggs, S. E.; Craig, W. W.; Brandt, W. N.; Luo, B.; Brightman, M.; Christensen, F. E.; Comastri, A.; Gandhi, P.; Hailey, C. J.; Madejski, G.; Marinucci, A.

    2014-01-01

    The Circinus galaxy is one of the closest obscured active galactic nuclei (AGNs), making it an ideal target for detailed study. Combining archival Chandra and XMM-Newton data with new NuSTAR observations, we model the 2-79 keV spectrum to constrain the primary AGN continuum and to derive physical parameters for the obscuring material. Chandra's high angular resolution allows a separation of nuclear and off-nuclear galactic emission. In the off-nuclear diffuse emission, we find signatures of strong cold reflection, including high equivalent-width neutral Fe lines. This Compton-scattered off-nuclear emission amounts to 18% of the nuclear flux in the Fe line region, but becomes comparable to the nuclear emission above 30 keV. The new analysis no longer supports a prominent transmitted AGN component in the observed band. We find that the nuclear spectrum is consistent with Compton scattering by an optically thick torus, where the intrinsic spectrum is a power law of photon index Γ = 2.2-2.4, the torus has an equatorial column density of N H = (6-10) × 10 24 cm –2 , and the intrinsic AGN 2-10 keV luminosity is (2.3-5.1) × 10 42 erg s –1 . These values place Circinus along the same relations as unobscured AGNs in accretion rate versus Γ and L X versus L IR phase space. NuSTAR's high sensitivity and low background allow us to study the short timescale variability of Circinus at X-ray energies above 10 keV for the first time. The lack of detected variability favors a Compton-thick absorber, in line with the spectral fitting results.

  20. Experimental determination of L X-ray fluorescence cross sections for elements with 45 < Z < 50 at 10 keV

    Directory of Open Access Journals (Sweden)

    Edgardo Bonzi

    2014-02-01

    Full Text Available Synchrotron radiation at 10 keV was used to experimentally determine the Ll, L, LI, LII, LI and LII fluorescence cross sections for elements with 45 < Z < 50, as part of an ongoing investigation at low energies. The measured data were compared with calculated values obtained using coefficients from Scofield, Krause and Puri et al. Received: 19 December 2013, Accepted: 20 January 2014; Reviewed by: J. P. Marques, Departamento de Física, Centro de Física Atómica, Fac. de Ciências, Universidade de Lisboa, Portugal.; Edited by: P. Weck; DOI: http://dx.doi.org/10.4279/PIP.060001 Cite as: E V Bonzi, G B Grad, R A Barrea, Papers in Physics 6, 060001 (2014

  1. Self-consistent method for quantifying indium content from X-ray spectra of thick compound semiconductor specimens in a transmission electron microscope.

    Science.gov (United States)

    Walther, T; Wang, X

    2016-05-01

    Based on Monte Carlo simulations of X-ray generation by fast electrons we calculate curves of effective sensitivity factors for analytical transmission electron microscopy based energy-dispersive X-ray spectroscopy including absorption and fluorescence effects, as a function of Ga K/L ratio for different indium and gallium containing compound semiconductors. For the case of InGaN alloy thin films we show that experimental spectra can thus be quantified without the need to measure specimen thickness or density, yielding self-consistent values for quantification with Ga K and Ga L lines. The effect of uncertainties in the detector efficiency are also shown to be reduced. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  2. Optimization of planar metallic nonrefracting transmission-grating profiles for M/sup th/-order intensity maximization in the soft x-ray range

    International Nuclear Information System (INIS)

    Tatchyn, R.; Csonka, P.L.; Lindau, I.

    1982-01-01

    In this paper, we derive the thickness profiles of metallic transmission-grating bars which maximize either the power throughput into the m/sup th/ diffracted order or the ratio of the m/sup th/-order diffracted power to the total output power (in the soft x-ray range). The derivation is performed for both general and symmetric bar shapes and for the two physically important cases of continuous gratings and gratings with integral bars. The solutions derived are shown to be valid for cases where the optical constants are generalized to be functions of position in a direction perpendicular to the grating bars. Examples of some optimum profiles for gold in the soft x-ray range are computed on the basis of the presented analysis and tabulated for convenient reference. 18 references

  3. X-ray and visible light transmission as two-dimensional, full-field moisture-sensing techniques: A preliminary comparison

    International Nuclear Information System (INIS)

    Tidwell, V.C.; Glass, R.J.

    1992-01-01

    Two independent high-resolution moisture-sensing techniques, x-ray absorption and light transmission, have been developed for use in two-dimensional, thin-slab experimental systems. The techniques yield full-field measurement capabilities with exceptional resolution of moisture content in time and space. These techniques represent powerful tools for the experimentalist to investigate processes governing unsaturated flow and transport through fractured and nonfractured porous media. Evaluation of these techniques has been accomplished by direct comparison of data obtained by means of the x-ray and light techniques as well as comparison with data collected by gravimetric and gamma-ray densitometry techniques. Results show excellent agreement between data collected by the four moisture-content measurement techniques. This program was established to support the Yucca Mountain Site Characterization Project

  4. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  5. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  7. A new spectroscopic imager for X-rays from 0.5 keV to 150 keV combining a pnCCD and a columnar CsI(Tl) scintillator

    Science.gov (United States)

    Schlosser, D. M.; Hartmann, R.; Kalok, D.; Bechteler, A.; Abboud, A.; Shokr, M.; Çonka, T.; Pietsch, U.; Strüder, L.

    2017-04-01

    By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 μm. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 μm.

  8. Studies of SmCo5/Fe nanocomposite magnetic bilayers with magnetic soft x-ray transmission microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shahzad, F.; Siddiqi, S. A.; Im, M.-Y.; Avallone, A.; Fischer, P.; Hussain, Z.; Siddiqi, I.; Hellman, F.; Zhao, J.

    2009-12-04

    A hard/soft SmCo{sub 5}/Fe nanocomposite magnetic bilayer system has been fabricated on X-ray transparent 100-200 nm thin Si{sub 3}N{sub 4} membranes by magnetron sputtering. The microscopic magnetic domain pattern and its behavior during magnetization reversal in the hard and soft magnetic phases have been individually studied by element specific magnetic soft x-ray microscopy at a spatial resolution of better than 25nm. We observe that the domain patterns for soft and hard phases switch coherently throughout the full hysteresis cycle upon applying external magnetic fields. We derived local M(H) curves from the images for Fe and SmCo5 separately and found switching for both hard and soft phases same.

  9. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  10. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  11. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities

    International Nuclear Information System (INIS)

    Kharrati, Hedi; Agrebi, Amel; Karaoui, Mohamed-Karim

    2007-01-01

    X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement. Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities

  12. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV; Respuesta TL de LiF: Mg, Cu, P+Ptfe a rayos X de 24, 42 y 100 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Tovar M, V.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy); Quiroz C, M.C. [Facultad de Medicina, UAEM, 50180 Toluca, Estado de Mexico (Mexico)

    2005-07-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  13. A Scanning Transmission X-ray Microscopy Study of Cubic and Orthorhombic C3A and Their Hydration Products in the Presence of Gypsum

    Directory of Open Access Journals (Sweden)

    Vanessa Rheinheimer

    2016-08-01

    Full Text Available This paper shows the microstructural differences and phase characterization of pure phases and hydrated products of the cubic and orthorhombic (Na-doped polymorphs of tricalcium aluminate (C3A, which are commonly found in traditional Portland cements. Pure, anhydrous samples were characterized using scanning transmission X-ray microscopy (STXM, X-ray photoelectron spectroscopy (XPS and X-ray diffraction (XRD and demonstrated differences in the chemical and mineralogical composition as well as the morphology on a micro/nano-scale. C3A/gypsum blends with mass ratios of 0.2 and 1.9 were hydrated using a water/C3A ratio of 1.2, and the products obtained after three days were assessed using STXM. The hydration process and subsequent formation of calcium sulfate in the C3A/gypsum systems were identified through the changes in the LIII edge fine structure for Calcium. The results also show greater Ca LII binding energies between hydrated samples with different gypsum contents. Conversely, the hydrated samples from the cubic and orthorhombic C3A at the same amount of gypsum exhibited strong morphological differences but similar chemical environments.

  14. Microfocussing of synchrotron X-rays using X-ray refractive lens developed at Indus-2 deep X-ray lithography beamline

    International Nuclear Information System (INIS)

    Dhamgaye, V.P.; Tiwari, M.K.; Lodha, G.S.; Sawhney, K.J.S.

    2014-01-01

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance sources are compared. (author)

  15. X-rays from supernova 1987A

    International Nuclear Information System (INIS)

    Xu, Y.; Sutherland, P.; Mccray, R.; Ross, R.R.

    1988-01-01

    Detailed calculations of the development of the X-ray spectrum of 1987A are presented using more realistic models for the supernova composition and density structure provided by Woosley. It is shown how the emergence of the X-ray spectrum depends on the parameters of the model and the nature of its central energy source. It is shown that the soft X-ray spectrum should be dominated by a 6.4 keV Fe K(alpha) emission line that could be observed by a sensitive X-ray telescope. 28 references

  16. Microstructural characterization of porous materials by X-ray microtomography and gamma ray transmission techniques; Caracterizacao da microestrutura de materiais porosos por microtomografia de raios X e transmissao de raios gama

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Anderson Camargo

    2006-07-01

    This work presents the application of the X-ray microtomography and gamma ray transmission techniques for the microstructure characterization of different kinds of materials. Total porosity, pore size distribution and the two point correlation functions were measured. The two point correlation function, which allows the reconstruction of 3D models, was carried out for two samples. Seven ceramic tablets of Alumina (Al{sub 2}O{sub 3}), seven tablets of Boron Carbide (B{sub 4}C), three samples of sedimentary rocks and one sample of Titanium foam were analyzed. The experimental set up for the Gamma Ray Transmission technique consisted of: a 2'' x 2'' crystal NaI(Tl) detector, an {sup 241} Am radioactive source (59,53 keV, 100 mCi), an automatic micrometric table for the sample XZ movement and standard gamma spectrometry electronics. Two microtomography systems were used: a Fein Focus system, constituted by an X-ray tube, operated at 160 kV and 0.3 to 1.1 mA, a CCD camera and the movement sample system, and a Skyscan system, model 1072, with a X-ray tube operated at 100 kV and 100{mu}A, and a CCD camera. The ceramic tablets, analyzed by the gamma ray transmission technique presented results for most of the porosities data with smaller confidence intervals and inside the intervals supplied by the tablets manufacturer. The Titanium porous sample was analyzed by the two techniques, its microtomography images achieved a resolution of 17{mu}m, obtained employing the Fein Focus system. For both techniques, this sample showed high porosity, which allows its application for this purpose. The sandstones samples were analyzed by the Skyscan system, achieving resolutions of 19{mu}m, 11{mu}m and 3.8{mu}m for each sample, respectively. The resolutions of 11{mu}m and 3.8{mu}m were the ones that generated better 2D sections for the respective samples and, consequently, more reliable porosities. The 3.8{mu}m resolution was the one that best quantified the pore size

  17. X-ray streak crystal spectography

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Brown, T.; Medecki, H.

    1983-01-01

    We have built an x-ray streaked crystal spectrograph for making time-resolved x-ray spectral measurements. This instrument can access Bragg angles from 11 0 to 38 0 and x-ray spectra from 200 eV to greater than 10 keV. We have demonstrated resolving powers, E/δE > 200 at 1 keV and time resolution less than 20 psec. A description of the instrument and an example of the data is given

  18. Scanning and transmission electron microscopy of a craniopharyngioma: x-ray microanalytical study of the intratumoral mineralized deposits

    Energy Technology Data Exchange (ETDEWEB)

    Vilches, J.; Lopez, A.; Martinez, M.C.; Gomez, J.; Barbera, J.

    This paper discusses the value of scanning electron microscopy (SEM) and x-ray microanalysis in the classification of craniopharyngiomas. This neoplasm shows epithelial nest, cords of cuboid cells, foci of squamous metaplasia, and microcystic degeneration. SEM reveals that the epithelial cysts are lined with elongated cells that possess numerous microvilli and blebs and that some cysts are lined with polyhedral cells. The microvilli are interpreted as characteristic of the fast growing craniopharyngiomas. A microanalytical study of the calcified areas reveals the presence of magnesium, phosphorus, and calcium.

  19. Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Noor Azman, N.Z. [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia); School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Siddiqui, S.A. [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia); Low, I.M., E-mail: j.low@curtin.edu.au [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia)

    2013-12-01

    Characteristics of X-ray transmissions were investigated for epoxy composites filled with 2–10 vol% WO{sub 3} loadings using synchrotron X-ray absorption spectroscopy (XAS) at 10–40 keV. The results obtained were used to determine the equivalent X-ray energies for the operating X-ray tube voltages of mammography and radiology machines. The results confirmed the superior attenuation ability of nano-sized WO{sub 3}-epoxy composites in the energy range of 10–25 keV when compared to their micro-sized counterparts. However, at higher synchrotron radiation energies (i.e., 30–40 keV), the X-ray transmission characteristics were similar with no apparent size effect for both nano-sized and micro-sized WO{sub 3}-epoxy composites. The equivalent X-ray energies for the operating X-ray tube voltages of the mammography unit (25–49 kV) were in the range of 15–25 keV. Similarly, for a radiology unit operating at 40–60 kV, the equivalent energy range was 25–40 keV, and for operating voltages greater than 60 kV (i.e., 70–100 kV), the equivalent energy was in excess of 40 keV. The mechanical properties of epoxy composites increased initially with an increase in the filler loading but a further increase in the WO{sub 3} loading resulted in deterioration of flexural strength, modulus and hardness. - Highlights: • Nano-sized WO{sub 3}-epoxy composites have superior x-ray shielding capability. • No size effect in x-ray attenuation was observed at 30–40 keV. • An optimum filler loading for improving the mechanical properties of WO{sub 3}-epoxy composites.

  20. Chemical and structural composition study through transmission and reflection electron microscopy and X-ray microanalysis of damaged duramater cardiac valves

    International Nuclear Information System (INIS)

    Verginelli, G.; Didio, L.J.A.; Puig, L.B.; Allen, D.J.; Highinson, G.H.; Zerbini, E.J.

    1982-01-01

    Ten malfunctioning durameter aortic prosthesis, excised surgically after 44 to 54 months of implantation were studied through transmission and reflection electron microscopy and X-ray microanalysis. Duramater extracted at necropsy but not used for valve prosthesis and duramater aortic prosthesis not implanted in patients were used as controls. It was concluded that homologous duramater valves present subcellular changes following implantation, with degenerating and proliferating areas which could correspond either to normal adaptation or consequence of degeneration - rebuilding which begins with implantation; it is also emphazised the need for ultramicroscopic studies in evaluating biological tissues and establishing its applicability in cardiac surgery. (M.A.C.) [pt

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  2. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  3. Hard X-ray irradiation of cosmic silicate analogs: structural evolution and astrophysical implications

    Science.gov (United States)

    Gavilan, L.; Jäger, C.; Simionovici, A.; Lemaire, J. L.; Sabri, T.; Foy, E.; Yagoubi, S.; Henning, T.; Salomon, D.; Martinez-Criado, G.

    2016-03-01

    Context. Protoplanetary disks, interstellar clouds, and active galactic nuclei contain X-ray-dominated regions. X-rays interact with the dust and gas present in such environments. While a few laboratory X-ray irradiation experiments have been performed on ices, X-ray irradiation experiments on bare cosmic dust analogs have been scarce up to now. Aims: Our goal is to study the effects of hard X-rays on cosmic dust analogs via in situ X-ray diffraction. By using a hard X-ray synchrotron nanobeam, we seek to simulate cumulative X-ray exposure on dust grains during their lifetime in these astrophysical environments and provide an upper limit on the effect of hard X-rays on dust grain structure. Methods: We prepared enstatite (MgSiO3) nanograins, which are analogs to cosmic silicates, via the melting-quenching technique. These amorphous grains were then annealed to obtain polycrystalline grains. These were characterized via scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) before irradiation. Powder samples were prepared in X-ray transparent substrates and were irradiated with hard X-rays nanobeams (29.4 keV) provided by beamline ID16B of the European Synchrotron Radiation Facility (Grenoble). X-ray diffraction images were recorded in transmission mode, and the ensuing diffractograms were analyzed as a function of the total X-ray exposure time. Results: We detected the amorphization of polycrystalline silicates embedded in an organic matrix after an accumulated X-ray exposure of 6.4 × 1027 eV cm-2. Pure crystalline silicate grains (without resin) do not exhibit amorphization. None of the amorphous silicate samples (pure and embedded in resin) underwent crystallization. We analyze the evolution of the polycrystalline sample embedded in an organic matrix as a function of X-ray exposure. Conclusions: Loss of diffraction peak intensity, peak broadening, and the disappearance of discrete spots and arcs reveal the amorphization

  4. Hard X-ray mirrors for Nuclear Security

    Energy Technology Data Exchange (ETDEWEB)

    Descalle, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brejnholt, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hill, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Decker, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alameda, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Soufli, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pivovaroff, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pardini, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-07

    Research performed under this LDRD aimed to demonstrate the ability to detect and measure hard X-ray emissions using multilayer X-ray reflective optics above 400 keV, to enable the development of inexpensive and high-accuracy mirror substrates, and to investigate applications of hard X-ray mirrors of interest to the nuclear security community. Experiments conducted at the European Synchrotron Radiation Facility demonstrated hard X-ray mirror reflectivity up to 650 keV for the first time. Hard X-ray optics substrates must have surface roughness under 3 to 4 Angstrom rms, and three materials were evaluated as potential substrates: polycarbonates, thin Schott glass and a new type of flexible glass called Willow Glass®. Chemical smoothing and thermal heating of the surface of polycarbonate samples, which are inexpensive but have poor intrinsic surface characteristics, did not yield acceptable surface roughness. D263 Schott glass was used for the focusing optics of the NASA NuSTAR telescope. The required specialized hardware and process were costly and motivated experiments with a modified non-contact slumping technique. The surface roughness of the glass was preserved and the process yielded cylindrical shells with good net shape pointing to the potential advantage of this technique. Finally, measured surface roughness of 200 and 130 μm thick Willow Glass sheets was between 2 and 2.5 A rms. Additional results of flexibility tests and multilayer deposition campaigns indicated it is a promising substrate for hard X-ray optics. The detection of U and Pu characteristics X-ray lines and gamma emission lines in a high background environment was identified as an area for which X-ray mirrors could have an impact and where focusing optics could help reduce signal to noise ratio by focusing signal onto a smaller detector. Hence the first one twelvetant of a Wolter I focusing optics for the 90 to 140 keV energy range based on aperiodic multilayer coating was designed. Finally

  5. Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, V. V., E-mail: VVYashchuk@lbl.gov; Chan, E. R.; Lacey, I. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Fischer, P. J. [Center for X-Ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Physics Department, University of California Santa Cruz, Santa Cruz, California 94056 (United States); Conley, R. [Advance Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); McKinney, W. R. [Diablo Valley College, 321 Golf Club Road, Pleasant Hill, California 94523 (United States); Artemiev, N. A. [KLA-Tencor Corp., 1 Technology Drive, Milpitas, California 95035 (United States); Bouet, N. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); Cabrini, S. [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Calafiore, G.; Peroz, C.; Babin, S. [aBeam Technologies, Inc., Hayward, California 94541 (United States)

    2015-12-15

    We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

  6. Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

    International Nuclear Information System (INIS)

    Yashchuk, V. V.; Chan, E. R.; Lacey, I.; Fischer, P. J.; Conley, R.; McKinney, W. R.; Artemiev, N. A.; Bouet, N.; Cabrini, S.; Calafiore, G.; Peroz, C.; Babin, S.

    2015-01-01

    We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters

  7. Compound refractive lenses for novel X-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Piestrup, M.A. E-mail: melpie@adelphitech.com; Beguiristain, H.R.; Gary, C.K.; Cremer, J.T.; Pantell, R.H.; Tatchyn, R

    2001-01-01

    We have measured the intensity profile of X-rays focused by a linear array of closely spaced spherical lenses fabricated using Mylar (C{sub 5}H{sub 4}O{sub 2}). We have experimentally demonstrated that we can achieve two-dimensional focusing for photon energies between 7 and 9 keV with imaging distances of less than 1 m. For example, using 8-keV X-rays we have achieved full-width-at-half-maximum (FWHM) linewidths down to 27.5 {mu}m at a distance of only 62 cm from the lens. The effective aperture of the lens was measured to be about 390 {mu}m with 38% transmission at 9 keV. A synchrotron source having source-size dimensions of 0.44x1.7 mm{sup 2} was utilized for the experimental work. Such lenses are seen as useful for focusing and increasing the intensity of novel X-ray sources that are directional and have small source size ({sigma}<1 mm)

  8. Characterization and cross calibration of Agfa D4, D7, and D8 and Kodak SR45 x-ray films against direct exposure film at 4.0-5.5 keV

    International Nuclear Information System (INIS)

    Lanier, N.E.; Cowan, J.S.; Workman, J.

    2006-01-01

    Kodak direct exposure film (DEF) [B. L. Henke et al., J. Opt. Soc. Am. B 3, 1540 (1986)] has been the standard for moderate energy (1-10 keV) x-ray diagnostic applications among the high-energy-density and inertial confinement fusion research communities. However, market forces have prompted Kodak to discontinue production of DEF, leaving these specialized communities searching for a replacement. We have conducted cross-calibration experiments and film characterizations on five possible substitutes for Kodak DEF. The film types studied were Kodak's Biomax MR (BMR) and SR45 along with Agfa's D8, D7, and D4sc. None of the films tested matched the speed of DEF. BMR and D8 were closest but D8 exhibited lower noise, with superior resolution and dynamic range. Agfa D7, Agfa D4sc, and Kodak SR45 were significantly less sensitive than BMR and D8, however, the improvements they yielded in resolution and dynamic range warrant their use if experimental constraints allow

  9. Transmission and fluorescence X-ray absorption spectroscopy cell/flow reactor for powder samples under vacuum or in reactive atmospheres

    KAUST Repository

    Hoffman, A. S.; Debefve, L. M.; Bendjeriou-Sedjerari, Anissa; Ould-Chikh, Samy; Bare, Simon R.; Basset, Jean-Marie; Gates, B. C.

    2016-01-01

    X-ray absorption spectroscopy is an element-specific technique for probing the local atomic-scale environment around an absorber atom. It is widely used to investigate the structures of liquids and solids, being especially valuable for characterization of solid-supported catalysts. Reported cell designs are limited in capabilities—to fluorescence or transmission and to static or flowing atmospheres, or to vacuum. Our goal was to design a robust and widely applicable cell for catalyst characterizations under all these conditions—to allow tracking of changes during genesis and during operation, both under vacuum and in reactive atmospheres. Herein, we report the design of such a cell and a demonstration of its operation both with a sample under dynamic vacuum and in the presence of gases flowing at temperatures up to 300 °C, showing data obtained with both fluorescence and transmission detection. The cell allows more flexibility in catalyst characterization than any reported.

  10. Transmission and fluorescence X-ray absorption spectroscopy cell/flow reactor for powder samples under vacuum or in reactive atmospheres

    KAUST Repository

    Hoffman, A. S.

    2016-07-26

    X-ray absorption spectroscopy is an element-specific technique for probing the local atomic-scale environment around an absorber atom. It is widely used to investigate the structures of liquids and solids, being especially valuable for characterization of solid-supported catalysts. Reported cell designs are limited in capabilities—to fluorescence or transmission and to static or flowing atmospheres, or to vacuum. Our goal was to design a robust and widely applicable cell for catalyst characterizations under all these conditions—to allow tracking of changes during genesis and during operation, both under vacuum and in reactive atmospheres. Herein, we report the design of such a cell and a demonstration of its operation both with a sample under dynamic vacuum and in the presence of gases flowing at temperatures up to 300 °C, showing data obtained with both fluorescence and transmission detection. The cell allows more flexibility in catalyst characterization than any reported.

  11. Cell survival studies using ultrasoft x rays

    International Nuclear Information System (INIS)

    Schillaci, M.E.; Raju, M.R.; Carpenter, S.; Cornforth, M.; Wilder, M.

    1987-01-01

    Cell survival was studied for V79 hamster, 10T1/2 mouse, and human skin fibroblast cell lines, using carbon K (0.28 keV), copper K (8.0 keV), and 250 kVp x rays. Because of the rapid attenuation of the carbon x rays, cellular dimensions at the time of exposure were measured using optical and electron microscopy, and frequency distributions of mean dose absorbed by the cell nucleus were obtained. The results indicate that the differences in cell killing between ultra-soft and hard x rays may depend on the nuclear thickness of the cells. Studies of the effects of hypoxia on V79 and 10T1/2 cells using carbon K, aluminum K (1.5 keV), and copper K x rays show decreasing OER values with decreasing x-ray energy and no difference between the two cell lines. Age response studies with V79 cells show similar cell-cycle variation of survival for carbon K and aluminum K x rays as for hard x rays

  12. Characterizing X-Ray and Radio Emission in the Black Hole X-Ray Binary V404 Cygni During Quiescence

    DEFF Research Database (Denmark)

    Rana, Vikram; Loh, Alan; Corbel, Stephane

    2016-01-01

    We present results from multi-wavelength simultaneous X-ray and radio observations of the black hole X-ray binary V404 Cyg in quiescence. Our coverage with NuSTAR provides the very first opportunity to study the X-ray spectrum of V404 Cyg at energies above 10 keV. The unabsorbed broadband (0...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  15. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  16. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  17. Analysis of the dislocation content in a deformed Co-based superalloy by transmission electron microscopy and X-ray diffraction

    International Nuclear Information System (INIS)

    Breuer, D.; Klimanek, P.; Muehle, U.; Martin, U.

    1997-01-01

    The present paper compares the dislocation densities as determined in a Co-based superalloy (CoNi22Cr22W14) after creep and tensile deformation by Transmission Electron Microscopy (TEM) and X-ray profile analysis (XRD). After creep tests the dislocation densities obtained by both methods are in good agreement, which is the result of a nearly homogeneous dislocation distribution. The relationship between the dislocation density and the flow stress meets the Taylor equation. After tensile deformation the dislocation densities determined by TEM and XRD differ systematically from each other, but in both cases also a Taylor relationship can be obtained. The constant α of the dislocation interaction derived by TEM is much larger than in the creep tests and also than that of the XRD, which agrees well with the creep data. The difference between the TEM and the XRD results is the consequence of the dislocation cell structure much more developed in the tensile specimens, which leads to an underestimation of the dislocation density in TEM because of overweighting the cell interior. By fitting the Fourier coefficients of the X-ray diffraction line shapes with a bimodal distribution of the defect content (composite model), dislocation densities of the cell interior can be estimated that correspond well to the TEM data. (orig.)

  18. BSRF-3B3 Medium Energy X-ray Beamline and Its Application for XAFS Research

    International Nuclear Information System (INIS)

    Ma Chenyan; Cui Mingqi; Zhou Kejin; Zhao Yidong; Tian Yulian; Wu Ziyu; Zheng Lei; Zhu Jie; Zhao Jia; Chen Kai; Sun Lijuan

    2007-01-01

    A new medium X-ray beamline 3B3 covering energy from 1.2 keV up to 6.0 keV was built at Beijing Synchrotron Radiation Facility (BSRF) in 2005. With perfect capability of high monochromaticity, good focus and low harmonics, it could be applied to study metrology, optic component characteristics and medium X-ray absorption spectroscopy (XAS). A simple XAFS apparatus has been set up and some measurements such as S, P, Cl, Ca, Al, Mg K-edge X-ray absorption fine structure (XAFS) in their compounds have also been carried out. The results show that it is feasible to do XAFS research at 3B3 beamline under present condition. The fabrication of a more delicate medium XAFS spectrometer is underway including transmission, fluorescence and electronic yield modes

  19. Experimental studies on pulse soft X-ray generator

    International Nuclear Information System (INIS)

    Li Chengrong; Yang Qinchi; Luo Chengmu; Han Min

    1990-01-01

    Emission sources of soft x rays (2 keV < hv < 6 keV) from hot plasmas have been studied in a small gas-puff Z-pinch. The emission sources are a group of uncontinuous hot spots. The output of soft x rays from the hot spots have been measured and the effect of the initial gas density on the yield of soft x rays has been investigated

  20. A comparative transmission electron microscopy, energy dispersive x-ray spectroscopy and spatially resolved micropillar compression study of the yttria partially stabilised zirconia - porcelain interface in dental prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Lunt, Alexander J.G., E-mail: alexander.lunt@chch.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Mohanty, Gaurav, E-mail: gaurav.mohanty@empa.ch [EMPA Materials Science & Technology, Feuerwerkerstrasse 39, CH-3602 Thun (Switzerland); Ying, Siqi, E-mail: siqi.ying@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Dluhoš, Jiří, E-mail: jiri.dluhos@tescan.cz [TESCAN Brno, s.r.o., Libušina tř. 1, 623 00 Brno-Kohoutovice (Czech Republic); Sui, Tan, E-mail: tan.sui@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Neo, Tee K., E-mail: neophyte@singnet.com.sg [Specialist Dental Group, Mount Elizabeth Orchard, 3 Mount Elizabeth, #08-03/08-08/08-10, 228510 (Singapore); Michler, Johann, E-mail: johann.michler@empa.ch [EMPA Materials Science & Technology, Feuerwerkerstrasse 39, CH-3602 Thun (Switzerland); Korsunsky, Alexander M., E-mail: alexander.korsunsky@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom)

    2015-12-01

    Recent studies into the origins of failure of yttria partially stabilised zirconia–porcelain veneered prosthesis have revealed the importance of micro-to-nano scale characterisation of this interface zone. Current understanding suggests that the heat treatment, residual stresses and varying microstructure at this location may contribute to near-interface porcelain chipping. In this study the chemical, microstructural and mechanical property variation across the interfacial zone has been characterised at two differing length scales and using three independent techniques; energy dispersive X-ray spectroscopy, transmission electron microscopy and micropillar compression. Energy dispersive X-ray spectroscopy mapping of the near-interface region revealed, for the first time, that the diffusional lengths of twelve principal elements are limited to within 2–6 μm of the interface. This study also revealed that 0.2–2 μm diameter zirconia grains had become detached from the bulk and were embedded in the near-interface porcelain. Transmission electron microscopy analysis demonstrated the presence of nanoscale spherical features, indicative of tensile creep induced voiding, within the first 0.4–1.5 μm from the interface. Within zirconia, variations in grain size and atomistic structure were also observed within the 3 μm closest to the interface. Micropillar compression was performed over a 100 μm range on either side of the interface at the spatial resolution of 5 μm. This revealed an increase in zirconia and porcelain loading modulus at close proximities (< 5 μm) to the interface and a decrease in zirconia modulus at distances between 6 and 41 μm from this location. The combination of the three experimental techniques has revealed intricate details of the microstructural, chemical and consequently mechanical heterogeneities in the YPSZ–porcelain interface, and demonstrated that the length scales typically associated with this behaviour are approximately ± 5

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  3. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  4. X-ray astronomy 2000: Wide field X-ray monitoring with lobster-eye telescopes

    International Nuclear Information System (INIS)

    Inneman, A.; Hudec, R.; Pina, L.; Gorenstein, P.

    2001-01-01

    The recently available first prototypes of innovative very wide field X-ray telescopes of Lobster-Eye type confirm the feasibility to develop such flight instruments in a near future. These devices are expected to allow very wide field (more than 1000 square degrees) monitoring of the sky in X-rays (up to 10 keV and perhaps even more) with faint limits. We will discuss the recent status of the development of very wide field X-ray telescopes as well as related scientific questions including expected major contributions such as monitoring and study of X-ray afterglows of Gamma Ray Bursts

  5. Arrangement for X-ray shield

    International Nuclear Information System (INIS)

    1980-01-01

    X-ray screen unit consisting of a light transmissive carrier onto which scintillation material is deposited, which is able to generate light under the influence of incident X-ray irradiation, characterised in that the X-ray screen comprises a number of sectors, wherein the surface with respect to the incident X-radiation is maintained at an acute angle. (G.C.)

  6. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  7. Microstructural changes in CdSe-coated ZnO nanowires evaluated by in situ annealing in transmission electron microscopy and x-ray diffraction

    International Nuclear Information System (INIS)

    Majidi, Hasti; Baxter, Jason B; Winkler, Christopher R; Taheri, Mitra L

    2012-01-01

    We report on the crystallite growth and phase change of electrodeposited CdSe coatings on ZnO nanowires during annealing. Both in situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) reveal that the nanocrystal size increases from ∼3 to ∼10 nm upon annealing at 350 °C for 1 h and then to more than 30 nm during another 1 h at 400 °C, exhibiting two distinct growth regimes. Nanocrystal growth occurs together with a structural change from zinc blende to wurtzite. The structural transition begins at 350 °C, which results in the formation of stacking faults. Increased crystallite size, comparable to the coating thickness, can improve charge separation in extremely thin absorber solar cells. We demonstrate a nearly two-fold improvement in power conversion efficiency upon annealing. (paper)

  8. Microstructural changes in CdSe-coated ZnO nanowires evaluated by in situ annealing in transmission electron microscopy and x-ray diffraction

    Science.gov (United States)

    Majidi, Hasti; Winkler, Christopher R.; Taheri, Mitra L.; Baxter, Jason B.

    2012-07-01

    We report on the crystallite growth and phase change of electrodeposited CdSe coatings on ZnO nanowires during annealing. Both in situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) reveal that the nanocrystal size increases from ˜3 to ˜10 nm upon annealing at 350 °C for 1 h and then to more than 30 nm during another 1 h at 400 °C, exhibiting two distinct growth regimes. Nanocrystal growth occurs together with a structural change from zinc blende to wurtzite. The structural transition begins at 350 °C, which results in the formation of stacking faults. Increased crystallite size, comparable to the coating thickness, can improve charge separation in extremely thin absorber solar cells. We demonstrate a nearly two-fold improvement in power conversion efficiency upon annealing.

  9. Revealing the synergetic effects in Ni nanoparticle-carbon nanotube hybrids by scanning transmission X-ray microscopy and their application in the hydrolysis of ammonia borane.

    Science.gov (United States)

    Zhao, Guanqi; Zhong, Jun; Wang, Jian; Sham, Tsun-Kong; Sun, Xuhui; Lee, Shuit-Tong

    2015-06-07

    The hybrids of carbon nanotubes (CNTs) and the supported Ni nanoparticles (NPs) have been studied by scanning transmission X-ray microscopy (STXM) and tested by the hydrolysis reaction of ammonia borane (AB, NH3BH3). Data clearly showed the existence of a strong interaction between Ni NPs and thin CNTs (C-O-Ni bonds), which favored the tunable (buffer) electronic structure of Ni NPs facilitating the catalytic process. The hydrolysis process of AB confirmed the hypothesis that the hybrids with a strong interfacial interaction would show superior catalytic performance, while the hybrids with a weak interfacial interaction show poor performance. Our results provide a wealth of detailed information regarding the electronic structure of the NP-CNT hybrids and provide guidance towards the rational design of high-performance catalysts for energy applications.

  10. Localization of lead within leaf cells of Rhytidiadelphus squarrosus (Hedw. ) Warnst. by means of transmission electron microscopy and X-ray microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Ophus, E M; Gullvag, B M

    1974-01-01

    Results of ultrastructural studies and transmission electron microscope microanalysis of leaves of the bryophyte Rhytidiadelphus squarrosus collected from a park in Trondheim are presented. The lead content of these leaves primarily derives from motor traffic exhaust gases. A fine structural examination of the leaf cells revealed that detectable amounts of lead had entered the cytoplasm and could be recognized as electron-dense precipitates localized inside the plasma membrane, within vesicles or vacuoles, chloroplasts, mitochondria, microbodies and plasmodesmata. Control material, fixed only in glutaraledhyde and not post-stained, showed that these precipitates must be due to metallic elements having great electron-scattering properties. TEM-X-ray microanalysis indicated the definite presence of lead and phosphorus within both the nuclear and chloroplast inclusions. The possible presence of some other metals is also discussed.

  11. Nanometer-scale, quantitative composition mappings of InGaN layers from a combination of scanning transmission electron microscopy and energy dispersive x-ray spectroscopy

    International Nuclear Information System (INIS)

    Pantzas, K; Voss, P L; Ougazzaden, A; Patriarche, G; Largeau, L; Mauguin, O; Troadec, D; Gautier, S; Moudakir, T; Suresh, S

    2012-01-01

    Using elastic scattering theory we show that a small set of energy dispersive x-ray spectroscopy (EDX) measurements is sufficient to experimentally evaluate the scattering function of electrons in high-angle annular dark field scanning transmission microscopy (HAADF-STEM). We then demonstrate how to use this function to transform qualitative HAADF-STEM images of InGaN layers into precise, quantitative chemical maps of the indium composition. The maps obtained in this way combine the resolution of HAADF-STEM and the chemical precision of EDX. We illustrate the potential of such chemical maps by using them to investigate nanometer-scale fluctuations in the indium composition and their impact on the growth of epitaxial InGaN layers. (paper)

  12. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  13. Simulation of transmitted X-rays in a polycapillary X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Shiqi [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Liu, Zhiguo, E-mail: liuzhiguo512@126.com [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi; Wang, Kai; Yi, Longtao; Yang, Kui; Chen, Man; Wang, Jinbang [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-09-21

    The geometrical description of capillary systems adjusted for the controlled guiding of X-rays and the basic theory of the transmission of X-rays are presented. A method of numerical calculation, based on Ray-Tracing theory, is developed to simulate the transmission efficiency of an X-ray parallel lens and the shape and size of the light spot gain from it. The simulation results for two half-lenses are in good agreement with the experimental results.

  14. L{sub {iota}}, L{sub {alpha}}, L{sub {beta}} and L{sub {gamma}} X-ray fluorescence cross-sections of heavy elements for the exciting photons energy 38.18, 43.95, 50.21 and 59.5 keV

    Energy Technology Data Exchange (ETDEWEB)

    Bastug, Arif [Department of Physics Education, College of Education, Erzincan University, 24030 Erzincan (Turkey)], E-mail: abastug40@hotmail.com

    2008-03-15

    The cross-sections for the production of L{sub {iota}}, L{sub {alpha}}, L{sub {beta}} and L{sub {gamma}} X-ray fluorescence (XRF) in Er, Ta, W, Au, Hg, Tl, Pb and Bi by photons with energies in the range 38-59.5 keV have been measured, using a standard doublereflection experimental set-up. Measurements have been performed using an annular 241 Am primary source and X-ray emitting secondary-exciter system. Experimental cross-sections have been compared with the theoretically calculated values of L X-ray cross-sections and fairly good agreement is observed between the experimental and theoretical values.

  15. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  16. X-ray microscopy in Aarhus

    International Nuclear Information System (INIS)

    Uggerhoej, Erik; Abraham-Peskir, Joanna V.

    2000-01-01

    The Aarhus imaging soft X-ray microscope is now a busy multi-user facility. The optical set-up will be described and project highlights discussed. a) Metal-induced structural changes in whole cells in solution. The effects of aluminum, copper, nickel and zinc on protozoa investigated by using a combination of light microscopy, confocal scanning laser microscopy and X-ray microscopy. b) Botanical studies by X-ray microscopy used to compliment electron microscopy studies. c) Sludge morphology and iron precipitation in Danish freshwater plants by combining X-ray, scanning electron and transmission electron microscopy

  17. X-ray emission characteristics of foam target plasmas

    International Nuclear Information System (INIS)

    Fronya, A.A.; Borisenko, N.G.; Chernodub, M.L.; Merkuliev, Yu.A.; Osipov, M.V.; Puzyrev, V.N.; Sahakyan, A.T.; Starodub, A.N.; Vasin, B.L.; Yakushev, O.F.

    2010-01-01

    Complete text of publication follows. Experimental results of laser radiation interaction with a foam targets are presented. The spatial, temporal and energy characteristics of x-ray plasma radiation have been investigated. The pinhole-camera and Schwarzschild objective have been used for the plasma image formation in different spectral ranges. The plasma image is registered by the Schwarzschild objective in a narrow spectral range 180 - 200 A. Spectral characteristics of x-ray radiation registered by pinhole-camera have been defined by means outer filters. The use of the filters with different transmission curves allowed one the determine the localization of x-ray radiation with fixed wavelength. Spatial resolution accounts 16 μm in the pinhole-camera diagnostic channel and 2.5 μm in the Schwarzschild objective diagnostic channel. The plasma images in the intrinsic x-ray radiation show that the emission area in the transverse direction with respect to the direction of the propagating heating radiation exceeds the focal spot size. This fact indicates that the target heating in the transverse direction is due to internal energy of the created plasma. The average value of plasma electron temperature is ∼ 0.4 - 1.4 keV. Acknowledgements. The work is partly supported by the Russian Foundation for Basic Researches, grant no. 10-02-00113 and by Federal Target Program 'Research and scientific-pedagogical cadres of Innovative Russia' (grant 2009-1.1-122-052-025).

  18. SphinX: The Solar Photometer in X-Rays

    Science.gov (United States)

    Gburek, Szymon; Sylwester, Janusz; Kowalinski, Miroslaw; Bakala, Jaroslaw; Kordylewski, Zbigniew; Podgorski, Piotr; Plocieniak, Stefan; Siarkowski, Marek; Sylwester, Barbara; Trzebinski, Witold; Kuzin, Sergey V.; Pertsov, Andrey A.; Kotov, Yurij D.; Farnik, Frantisek; Reale, Fabio; Phillips, Kenneth J. H.

    2013-04-01

    Solar Photometer in X-rays (SphinX) was a spectrophotometer developed to observe the Sun in soft X-rays. The instrument observed in the energy range ≈ 1 - 15 keV with resolution ≈ 0.4 keV. SphinX was flown on the Russian CORONAS-PHOTON satellite placed inside the TESIS EUV and X telescope assembly. The spacecraft launch took place on 30 January 2009 at 13:30 UT at the Plesetsk Cosmodrome in Russia. The SphinX experiment mission began a couple of weeks later on 20 February 2009 when the first telemetry dumps were received. The mission ended nine months later on 29 November 2009 when data transmission was terminated. SphinX provided an excellent set of observations during very low solar activity. This was indeed the period in which solar activity dropped to the lowest level observed in X-rays ever. The SphinX instrument design, construction, and operation principle are described. Information on SphinX data repositories, dissemination methods, format, and calibration is given together with general recommendations for data users. Scientific research areas in which SphinX data find application are reviewed.

  19. X-ray investigations of the hot ISM

    Science.gov (United States)

    Sanders, W. T.

    1993-01-01

    At energies less than one keV, the intensity of the galactic x-ray background dominates that of the extragalactic background in almost every direction on the sky. Below 1/4 keV, the galactic x-ray background has a galactic stellar component, but the dominant emitter seems to be hot interstellar matter. The origin of the general 3/4 keV x-ray background remains uncertain, but one component must also be the contribution from hot interstellar matter. An overview is given of recent x-ray investigations of the hot interstellar medium using data from the ROSAT X-ray Telescope/Position-Sensitive Proportional Counter (XRT/PSPC) instrument. Several prominent features in the low energy x-ray background that are interpreted as fossil supernova remnants are discussed.

  20. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  1. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  2. Ultrashort X-ray pulse science

    International Nuclear Information System (INIS)

    Chin, A.H.; Lawrence Berkeley National Lab., CA

    1998-01-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90 o Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ∼ 300 fs, 30 keV (0.4 (angstrom)) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been

  3. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  4. Use of proportional counter in X-Ray spectrometry between 5 and 100 keV. Application to the detection of fission products and to the determination of absolute X-Ray disintegration rates; Utilisation d'un compteur proportionnel en spectrometrie de rayons X entre 5 et 100 keV. Application a la detection des produits de fission et a la determination des taux d'emission X absolus

    Energy Technology Data Exchange (ETDEWEB)

    Cerf, J [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1969-07-01

    The measurement of electromagnetic radiations is difficult in the energy range 20-100 keV. We made suitable for this purpose a regular proportional counter, modifying both the nature and pressure of the gaseous mixture filling the detector volume. We selected the CPEN-SAIP counter, which is able to withstand such modifications. In the energy range considered, the counter is to be standardized with radioactive sources. Such standards were selected according to their disintegration schemes. We thus defined the conditions of use (resolution, yield) of the CPN counter, filled with an argon-methane mixture under a pressure of about 3 bars, in the energy range 5-100 keV. With such an equipment, we were able to measure the absolute disintegration rate for the X-rays of 133 Ba and 75 Se, then to perform the study of a mixed fission products sample. In the same way, we used xenon-based gaseous mixtures, in order to improve the detector yield; in the later case, we carefully examined the limitations introduced by the presence of many parasite rays emitted by the gas. We thus displayed in addition to the leakage peak, the fluorescence ray of the gas, whose origin is difficult to explain. (author) [French] La mesure des rayonnements electromagnetiques est difficile dans une bande d'energie comprise entre 20 et 100 keV environ. Nous avons rendu utilisable, a cet effet, un compteur proportionnel existant en modifiant la nature et la pression du melange gazeux constituant le volume detecteur. De par sa construction, le compteur CPXN, fabrique par les Etablissements S.A.I.P., rend ces experiences possibles. C'est pourquoi nous l'avons choisi. Dans le domaine d'energie consideree l'etalonnage du compteur necessite l'emploi de sources radioactives. Pour les preparer, nous sommes amenes a choisir les radio-nucleides utilisables par l'etude de leur schema de desintegration. Ainsi, nous avons defini les conditions d'utilisation (resolution, efficacite) du compteur CPNX rempli d

  5. The 2-ID-B intermediate-energy scanning X-ray microscope at the APS

    International Nuclear Information System (INIS)

    McNulty, I.; Paterson, D.; Arko, J.; Erdmann, M.; Goetze, K.; Ilinski, P.; Mooney, T.; Vogt, S.; Xu, S.; Frigo, S.P.; Stampfl, A.P.J.; Wang, Y.

    2002-01-01

    The intermediate-energy scanning x-ray microscope at beamline 2-ID-B at the Advanced Photon Source is a dedicated instrument for materials and biological research. The microscope uses a zone plate lens to focus coherent 1-4 keV x-rays to a 60 nm focal spot of 10 9 photons/s onto the sample. It records simultaneous transmission and energy-resolved fluorescence images. We have used the microscope for nano-tomography of chips and micro-spectroscopy of cells. (authors)

  6. Transmission microscopy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft X-ray photons

    International Nuclear Information System (INIS)

    Sayre, D.; Feder, R.; Spiller, E.; Kirz, J.; Kim, D.M.

    1977-01-01

    The minimum radiation dosage in a specimen consistent with transmission microscopy at resolution d and specimen thickness t is calculated for model specimens resembling biological materials in their natural state. The calculations cover 10 4 -10 7 eV electrons and 1.3-90 A photons in a number of microscopy modes. The results indicate that over a considerable part of the (t,d)-plane transmission microscopy on such specimens can be carried out at lower dosage with photons than with electrons. Estimates of the maximum resolutions obtainable with electrons and photons, consistent with structural survival of the specimen, are obtained, as are data on optimal operating conditions for microscopy with the two particles

  7. Interfacial reaction pathways and kinetics during annealing of 111-textured Al/TiN bilayers: A synchrotron x-ray diffraction and transmission electron microscopy study

    International Nuclear Information System (INIS)

    Chun, J.-S.; Desjardins, P.; Lavoie, C.; Petrov, I.; Cabral, C. Jr.; Greene, J. E.

    2001-01-01

    Growth of TiN layers in most diffusion-barrier applications is limited to deposition temperatures T s s =450 deg. C on SiO 2 by ultrahigh vacuum reactive magnetron sputter deposition in pure N 2 . Al overlayers, 160 nm thick with inherited 111 preferred orientation, were then deposited at T s =100 deg. C without breaking vacuum. The as-deposited TiN layer is underdense due to the low deposition temperature (T s /T m ≅0.23 in which T m is the melting point) resulting in kinetically limited adatom mobilities leading to atomic shadowing which, in turn, results in a columnar microstructure with both inter- and intracolumnar voids. The Al overlayer is fully dense. Synchrotron x-ray diffraction was used to follow interfacial reaction kinetics during postdeposition annealing of the 111-textured Al/TiN bilayers as a function of time (t a =12-1200 s) and temperature (T a =440-550 deg. C). Changes in bilayer microstructure and microchemistry were investigated using transmission electron microscopy (TEM) and scanning TEM to obtain compositional maps of plan-view and cross-sectional specimens. Interfacial reaction during annealing is initiated at the Al/TiN interface. Al diffuses rapidly into TiN voids during anneals at temperatures ∼ 3 Ti at the interface. Al 3 Ti exhibits a relatively planar growth front extending toward the Al free surface. Analyses of time-dependent x-ray diffraction peak intensities during isothermal annealing as a function of temperature show that Al 3 Ti growth kinetics are, for the entire temperature range investigated, diffusion limited with an activation energy of 1.5±0.2 eV

  8. X-ray lenses with large aperture

    International Nuclear Information System (INIS)

    Simon, Markus

    2010-01-01

    Up to now, most X-ray imaging setups are based on absorption contrast imaging. There is a demand for focused X-rays in many X-ray analysis applications, either to increase the resolution of an imaging system, or, to reduce the time effort of an experiment through higher photon flux. For photon energies higher than 15 keV refractive X-ray optics are more efficient in comparison to non-refractive X-ray optics. The aim of this work was to develop X-ray lenses with large apertures and high transparency. By increasing the number of refracting surfaces while removing unnecessary lens material such lenses have been developed. Utilizing this approach the overall beam deflection angle is large with respect to the lens material it propagates through and so the transparency of the lens is increased. Within this work, X-ray lenses consisting of several thousands of prisms with an edge length in the range of micrometers have been developed and fabricated by deep X-ray lithography. Deep X-ray lithography enables high precision microstrucures with smooth sidewalls and large aspect ratios. The aperture of high-transparency X-ray lenses made this way is greater than 1 mm. They are suitable for photon energies in the range of 8 keV to 24 keV and offer a focal width of smaller than 10 μm at a transparency of around 40%. Furthermore, rolled X-ray lenses have been developed, that are made out of a microstructured polyimide film, which is cut according to the requirements regarding focal length and photon energy. The microstructured film is fabricated by molding, using an anisotropically etched silicon wafer as molding tool. Its mean roughness is in the range of nanometers. The film features prismatic structures, its surface topology is similar to an asparagus field. The measured diameter of the point focus was 18 μm to 31 μm, the calculated opticla efficiency was 37%. Future work will concentrate on increasing the aspect ratio of Prism Lenses and on increasing the rolling accuracy

  9. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  10. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  11. Micro-fresnel structures for microscopy of laser generated bright x-ray sources

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Shavers, D.C.; Flanders, D.C.; Smith, H.I.

    1979-01-01

    A brief parametric survey of the x-ray characteristics of a gold micro-disk irradiated at 3 x 10 14 watt/cm 2 by a 1 nsec Nd-glass laser pulse has been provided as an example of a laser generated bright x-ray source. It was shown that a simple phenomenological model of the laser generated x-ray source as a microscopic equilibrium plasma radiating as a blackbody for a finite time determined by its hydrodynamic disassembly and radiation losses, serves to provide an adequate approximation to the x-ray characteristics of such sources. The current state of x-ray microscopy within the LLL laser fusion program was briefly reviewed. Kirpatrick--Baez grazing incidence reflection x-ray microscopes are being used to provide 3 to 5 μm resolution, broadband images (ΔE/E approx. 0.3) over a spectral range from .6 keV to 3.5 keV. Zone Plate Coded Imaging is used to provide 5 to 10 μm resolution, broadband (ΔE/E approx. 0.5) images over a spectral range from 3 keV to 50 keV. Efficient x-ray lensing elements with anticipated submicron resolution are being developed for narrowband (ΔE/E approx. 10 -2 ) imaging applications over a spectral range .1 keV to 8 keV. The x-ray lens design is that of a transmission blazed Fresnel phase plate. Micro--Fresnel zone plates with 3200 A minimum linewidth have been fabricated and preliminary resolution tests begun. The first resolution test pattern, having minimum linewidth of 2.5 μm, was imaged in lambda = 8.34 A light with no difficulty. Newer test patterns with submicron minimum line are being prepared for the next stage of resolution testing. An off-axis Fresnel zone plate with 1600 A minimum linewidth is presently being fabricated for use as an imaging spectrometer in order to provide spatially separated, chromatically distinct images of characteristic line emissions from laser fusion targets

  12. X-ray interferometric Fourier holography

    International Nuclear Information System (INIS)

    Balyan, M.K.

    2016-01-01

    The X-ray interferometric Fourier holography is proposed and theoretically investigated. Fourier The X-ray interferometric Young fringes and object image reconstruction are investigated. It is shown that the interference pattern of two slits formed on the exit surface of the crystal-analyzer (the third plate of the interferometer) is the X-ray interferometric Young fringes. An expression for X-ray interferometric Young fringes period is obtained. The subsequent reconstruction of the slit image as an object is performed by means of Fourier transform of the intensity distribution on the hologram. Three methods of reconstruction of the amplitude transmission complex function of the object are presented: analytical - approximate method, method of iteration and step by step method. As an example the X-ray Fourier interferometric hologram recording and the complex amplitude transmission function reconstruction for a beryllium circular wire are considered

  13. Effective Energy Determination Of Radiodiagnostic X-Rays

    International Nuclear Information System (INIS)

    Sumarni; Mart, Terry

    2000-01-01

    X-rays have been used for diagnostic radiology to produce image on film that give anatomy information. Effective energy should be known to get benefit exposure. Half value layer (HVL) as shown as monoenergetic x-rays has similar spectra of energy x-rays. It has been done measurement with x-ray machine Tanka at P3KRBIN-Batan for 40 kVp to 119 kVp of potential found of Aluminium HVL are 0.115 cm to 0.385 cm and energy effective between 23.24 keV to 37.5 keV

  14. Scanning transmission X-ray microscopy probe for in situ mechanism study of graphene-oxide-based resistive random access memory.

    Science.gov (United States)

    Nho, Hyun Woo; Kim, Jong Yun; Wang, Jian; Shin, Hyun-Joon; Choi, Sung-Yool; Yoon, Tae Hyun

    2014-01-01

    Here, an in situ probe for scanning transmission X-ray microscopy (STXM) has been developed and applied to the study of the bipolar resistive switching (BRS) mechanism in an Al/graphene oxide (GO)/Al resistive random access memory (RRAM) device. To perform in situ STXM studies at the C K- and O K-edges, both the RRAM junctions and the I0 junction were fabricated on a single Si3N4 membrane to obtain local XANES spectra at these absorption edges with more delicate I0 normalization. Using this probe combined with the synchrotron-based STXM technique, it was possible to observe unique chemical changes involved in the BRS process of the Al/GO/Al RRAM device. Reversible oxidation and reduction of GO induced by the externally applied bias voltages were observed at the O K-edge XANES feature located at 538.2 eV, which strongly supported the oxygen ion drift model that was recently proposed from ex situ transmission electron microscope studies.

  15. Transmission of broad W/Rh and W/Al (target/filter) x-ray beams operated at 25-49 kVp through common shielding materials.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2012-07-01

    To provide transmission data for broad 25-39 kVp (kilovolt peak) W/Rh and 25-49 kVp W/Al (target/filter, W-tungsten, Rh-rhodium, and Al-aluminum) x-ray beams through common shielding materials, such as lead, concrete, gypsum wallboard, wood, steel, and plate glass. The unfiltered W-target x-ray spectra measured on a Selenia Dimensions system (Hologic Inc., Bedford, MA) set at 20-49 kVp were, respectively, filtered using 50-μm Rh and 700-μm Al, and were subsequently used for Monte Carlo calculations. The transmission of broad x-ray beams through shielding materials was simulated using Geant4 low energy electromagnetic physics package with photon- and electron-processes above 250 eV, including photoelectric effect, Compton scattering, and Rayleigh scattering. The calculated transmission data were fitted using Archer equation with a robust fitting algorithm. The transmission of broad x-ray beams through the above-mentioned shielding materials was calculated down to about 10(-5) for 25-39 kVp W/Rh and 25-49 kVp W/Al. The fitted results of α, β, and γ in Archer equation were provided. The α values of kVp ≥ 40 were approximately consistent with those of NCRP Report No. 147. These data provide inputs for the shielding designs of x-ray imaging facilities with W-anode x-ray beams, such as from Selenia Dimensions.

  16. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  17. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  18. X-rays utilization

    International Nuclear Information System (INIS)

    Rebigan, F.

    1979-03-01

    The modality of X-ray utilization in different activities and economy is given. One presents firstly quantities and units used in radiation dosimetry and other fields. One gives the generation of X-rays, their properties as well as the elements of radiation protection. The utilization characteristics of these radiations in different fields are finally given. (author)

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  20. X rays from radio binaries

    International Nuclear Information System (INIS)

    Apparao, K.M.V.

    1977-01-01

    Reference is made to the radio binary systems CC Cas, AR Lac, β Per (Algol), β Lyr, b Per and Cyg X-1. It is stated that a thermal interpretation of the radiation from Algol requires a much larger x-ray flux than the observed value of 3.8 x 10 -11 erg/cm 2 /sec/keV in the 2 to 6 keV energy range. Observations of some non-thermal flares, together with the small size of the radio source in Algol, indicate that the radio emission is non-thermal in nature. The radio emission is interpreted as synchrotron radiation and it is suggested that the observed x-ray emission is due to inverse Compton scattering of the light of the primary star by the radio electrons. The x-ray emission from other radio binaries is also calculated using this model. The energy for the radio electrons can arise from annihilation of magnetic lines connecting the binary stars, twisted by the rotation of the stars. (U.K.)

  1. X-ray clusters of galaxies

    International Nuclear Information System (INIS)

    McKee, J.D.

    1980-01-01

    This work is in three chapters, of which the first is an introduction to clusters of galaxies. The second chapter describes the HEAO A-2 Survey of Abell Clusters. The 225 clusters of galaxies listed in Abell's (1958) catalog which are of distance class four or less, were surveyed for 2 to 10 keV x-ray emission. Thirty-two identifications of x-ray sources with the clusters were made, fluxes and error boxes were determined for these sources; twelve of the identifications are new. The x-ray luminosity function has been derived and analytical fits have been made, the best fit is f(L) = 26.9 x 10 -8 exp( - L 44 /1.7) per Mpc per 10 44 erg s -1 per 2 to 10 keV band pass. The relationship between x-ray luminosity, Bautz-Morgan type, Rood-Sastry type, and richness has also been examined. The contribution of clusters to the x-ray background has been calculated from the luminosity function and has been found to be 3.5%, and with 90% certainty, less than 8% in the 2 to 10 keV band pass, assuming that clusters were not brighter in the past than they are at present. If they were bright enough in the past to account for the x-ray background, the evolution must have scaled more rapidly than (1 + z) 7 if clusters formed at z = 3, or (1 + z) 5 if clusters formed at z = 10. Chapter Three examines x-ray emission from poor clusters of galaxies. Burns and Owens' (1979) sample of 25 4C radio sources which coincide with Zwicky clusters of galaxies has been searched for x-ray emission in the HEAO A-2 data base. X-ray emission was detected from five sources at the 3sigma level, two exceeded 5 sigma. The search for x-ray emission was prompted by the knowledge of the existence of distorted radio sources in the clusters. The distortion implies the presence of a relatively dense intracluster medium which is expected to produce thermal bremsstrahlung x-ray emission

  2. Achromatic X-ray lenses

    International Nuclear Information System (INIS)

    Umbach, Marion

    2009-01-01

    This thesis presents first results on the development of achromatic refractive X-ray lenses which can be used for scientific experiments at synchrotron sources. First of all the different requirements for achromatic X-ray lenses have been worked out. There are different types of lenses, one type can be used for monochromatized sources when the energy is scanned while the spot size should be constant. The other type can be used at beamlines providing a broad energy band. By a combination of focusing and defocusing elements we have developed a lens system that strongly reduces the chromatic aberration of a refractive lens in a given energy range. The great challenge in the X-ray case - in contrast to the visible range - the complex refractive index, which is very similar for the possible materials in the X-ray spectrum. For precise studies a numerical code has been developed, which calculates the different rays on their way through the lenses to the detector plane via raytracing. In this numerical code the intensity distribution in the detector plane has been analyzed for a chromatic and the corresponding achromatic system. By optimization routines for the two different fields of applications specific parameter combinations were found. For the experimental verification an achromatic system has been developed, consisting of biconcave SU-8 lenses and biconvex Nickel Fresnel lenses. Their fabrication was based on the LIGA-process, including a further innovative development, namely the fabrication of two different materials on one wafer. In the experiment at the synchrotron source ANKA the energy was varied in a specific energy range in steps of 0.1 keV. The intensity distribution for the different energies was detected at a certain focal length. For the achromatic system a reduction of the chromatic aberration could be clearly shown. Achromatic refractive X-ray lenses, especially for the use at synchrotron sources, have not been developed so far. As a consequence of the

  3. Time-resolved suprathermal x-rays

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Rosen, M.D.

    1978-01-01

    Temporally resolved x-ray spectra in the range of 1 to 20 keV have been obtained from gold disk targets irradiated by 1.06 μm laser pulses from the Argus facility. The x-ray streak camera used for the measurement has been calibrated for streak speed and dynamic range by using an air-gap Fabry-Perot etalon, and the instrument response has been calibrated using a multi-range monoenergetic x-ray source. The experimental results indicate that we are able to observe the ''hot'' x-ray temperature evolve in time and that the experimentally observed values can be qualitatively predicted by LASNEX code computations when the inhibited transport model is used

  4. X-ray Optics Development at MSFC

    Science.gov (United States)

    Sharma, Dharma P.

    2017-01-01

    Development of high resolution focusing telescopes has led to a tremendous leap in sensitivity, revolutionizing observational X-ray astronomy. High sensitivity and high spatial resolution X-ray observations have been possible due to use of grazing incidence optics (paraboloid/hyperboloid) coupled with high spatial resolution and high efficiency detectors/imagers. The best X-ray telescope flown so far is mounted onboard Chandra observatory launched on July 23,1999. The telescope has a spatial resolution of 0.5 arc seconds with compatible imaging instruments in the energy range of 0.1 to 10 keV. The Chandra observatory has been responsible for a large number of discoveries and has provided X-ray insights on a large number of celestial objects including stars, supernova remnants, pulsars, magnetars, black holes, active galactic nuclei, galaxies, clusters and our own solar system.

  5. X-ray tube transformer

    International Nuclear Information System (INIS)

    1980-01-01

    An X-ray generator is described which comprises a transmission line transformer including an electrical conductor with a cavity and a second electrical conductor including helical windings disposed along a longitudinal axis within the cavity of the first conductor. The windings have a pitch which varies per unit length along the axis. There is dielectric material in the cavity for insulation and to couple electromagnetically the two conductors in response to an electric current flowing through the conductors, which have an impedance between them; this varies with distance along the axis of the helix of the second conductor. An X-ray tube is disposed along the longitudinal axis within the cavity, for radiating X-rays. The invention increases the voltage of applied voltage pulses at the remote tube-head with a transformer formed by using a spiral delay line geometry to give a tapered-impedance coaxial high voltage multiplier for pulse voltage operation. This transformer is smaller and lighter than previous designs for the same high peak voltage and power ratings. This is important because the penetration capabilities of Flash X-ray equipment increase with voltage, particularly in heavy materials such as steel. (U.K.)

  6. Position sensitive x-ray detector

    International Nuclear Information System (INIS)

    Macchione, E.L.A.

    1990-01-01

    A multi ware position sensitive gas counter for X-ray detection was developed in our laboratory, making use of commercial delay-lines for position sensing. Six delay-line chips (50 ns delay each, 40 Mhz cut-off frequency) cover a total sensitive length of 150 mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9 keV X-ray line from a 55 Fe source and integral linearity better than 0,1% and a maximal differential linearity of ±4,0% were obtained operating the detector with an Ar-C H 4 (90%-10%) gas mixture at 700 torr. Similar tests were performed, using the 8,04 keV line from a Cu x-ray tube. A total resolution of 330 μm, and the same integral and differential linearities were obtained. (author)

  7. Nanofocusing Parabolic Refractive X-Ray Lenses

    International Nuclear Information System (INIS)

    Schroer, C.G.; Kuhlmann, M.; Hunger, U.T.; Guenzler, T.F.; Kurapova, O.; Feste, S.; Lengeler, B.; Drakopoulos, M.; Somogyi, A.; Simionovici, A. S.; Snigirev, A.; Snigireva, I.

    2004-01-01

    Parabolic refractive x-ray lenses with short focal distance can generate intensive hard x-ray microbeams with lateral extensions in the 100nm range even at short distance from a synchrotron radiation source. We have fabricated planar parabolic lenses made of silicon that have a focal distance in the range of a few millimeters at hard x-ray energies. In a crossed geometry, two lenses were used to generate a microbeam with a lateral size of 330nm by 110nm at 25keV in a distance of 41.8m from the synchrotron radiation source. First microdiffraction and fluorescence microtomography experiments were carried out with these lenses. Using diamond as lens material, microbeams with lateral size down to 20nm and below are conceivable in the energy range from 10 to 100keV

  8. Nanofocusing parabolic refractive x-ray lenses

    International Nuclear Information System (INIS)

    Schroer, C.G.; Kuhlmann, M.; Hunger, U.T.; Guenzler, T.F.; Kurapova, O.; Feste, S.; Frehse, F.; Lengeler, B.; Drakopoulos, M.; Somogyi, A.; Simionovici, A.S.; Snigirev, A.; Snigireva, I.; Schug, C.; Schroeder, W.H.

    2003-01-01

    Parabolic refractive x-ray lenses with short focal distance can generate intensive hard x-ray microbeams with lateral extensions in the 100 nm range even at a short distance from a synchrotron radiation source. We have fabricated planar parabolic lenses made of silicon that have a focal distance in the range of a few millimeters at hard x-ray energies. In a crossed geometry, two lenses were used to generate a microbeam with a lateral size of 380 nm by 210 nm at 25 keV in a distance of 42 m from the synchrotron radiation source. Using diamond as the lens material, microbeams with a lateral size down to 20 nm and below are conceivable in the energy range from 10 to 100 keV

  9. Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays.

    Science.gov (United States)

    Azman, N Z Noor; Siddiqui, S A; Low, I M

    2013-12-01

    Characteristics of X-ray transmissions were investigated for epoxy composites filled with 2-10 vol% WO3 loadings using synchrotron X-ray absorption spectroscopy (XAS) at 10-40 keV. The results obtained were used to determine the equivalent X-ray energies for the operating X-ray tube voltages of mammography and radiology machines. The results confirmed the superior attenuation ability of nano-sized WO3-epoxy composites in the energy range of 10-25 keV when compared to their micro-sized counterparts. However, at higher synchrotron radiation energies (i.e., 30-40 keV), the X-ray transmission characteristics were similar with no apparent size effect for both nano-sized and micro-sized WO3-epoxy composites. The equivalent X-ray energies for the operating X-ray tube voltages of the mammography unit (25-49 kV) were in the range of 15-25 keV. Similarly, for a radiology unit operating at 40-60 kV, the equivalent energy range was 25-40 keV, and for operating voltages greater than 60 kV (i.e., 70-100 kV), the equivalent energy was in excess of 40 keV. The mechanical properties of epoxy composites increased initially with an increase in the filler loading but a further increase in the WO3 loading resulted in deterioration of flexural strength, modulus and hardness. © 2013.

  10. Quantitative Phase Imaging Using Hard X Rays

    International Nuclear Information System (INIS)

    Nugent, K.A.; Gureyev, T.E.; Cookson, D.J.; Paganin, D.; Barnea, Z.

    1996-01-01

    The quantitative imaging of a phase object using 16keV xrays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. We find that our phase image is in quantitative agreement with independent measurements of the object. copyright 1996 The American Physical Society

  11. X-ray characterization of curved crystals for hard x-ray astronomy

    Science.gov (United States)

    Buffagni, Elisa; Bonnini, Elisa; Ferrari, Claudio; Virgilli, Enrico; Frontera, Filippo

    2015-05-01

    Among the methods to focus photons the diffraction in crystals results as one of the most effective for high energy photons. An assembling of properly oriented crystals can form a lens able to focus x-rays at high energy via Laue diffraction in transmission geometry; this is a Laue lens. The x-ray diffraction theory provides that the maximum diffraction efficiency is achieved in ideal mosaic crystals, but real mosaic crystals show diffraction efficiencies several times lower than the ideal case due to technological problems. An alternative and convenient approach is the use of curved crystals. We have recently optimized an efficient method based on the surface damage of crystals to produce self-standing uniformly curved Si, GaAs and Ge tiles of thickness up to 2-3 mm and curvature radii R down to a few meters. We show that, for curved diffracting planes, such crystals have a diffraction efficiency nearly forty times higher than the diffraction efficiency of perfect similar flat crystals, thus very close to that of ideal mosaic crystals. Moreover, in an alternative configuration where the diffracting planes are perpendicular to the curved ones, a focusing effect occurs and will be shown. These results were obtained for several energies between 17 and 120 keV with lab sources or at high energy facilities such as LARIX at Ferrara (Italy), ESRF at Grenoble (France), and ANKA at Karlsruhe (Germany).

  12. X-ray diffraction and high resolution transmission electron microscopy characterization of intermetallics formed in Fe/Ti nanometer-scale multilayers during thermal annealing

    International Nuclear Information System (INIS)

    Wu, Z.L.; Peng, T.X.; Cao, B.S.; Lei, M.K.

    2009-01-01

    Intermetallics formation in the Fe/Ti nanometer-scale multilayers magnetron-sputtering deposited on Si(100) substrate during thermal annealing at 623-873 K was investigated by using small and wide angle X-ray diffraction and cross-sectional high-resolution transmission electron microscopy. The Fe/Ti nanometer-scale multilayers were constructed with bilayer thickness of 16.2 nm and the sublayer thickness ratio of 1:1. At the annealing temperature of 623 K, intermetallics FeTi were formed by nucleation at the triple joins of α-Fe(Ti)/α-Ti interface and α-Ti grain boundary with an orientational correlation of FeTi(110)//α-Ti(100) and FeTi[001]//α-Ti[001] to adjacent α-Ti grains. The lateral growth of intermetallics FeTi which is dependent on the diffusion path of Ti led to a coalescence into an intermetallic layer. With an increase in the annealing temperature, intermetallics Fe 2 Ti were formed between the intermetallics FeTi and the excess Fe due to the limitation of Fe and Ti atomic concentrations, resulting in the coexistence of intermetallics FeTi and Fe 2 Ti. It was found that the low energy interface as well as the dominant diffusion path constrained the nucleation and growth of intermetallics during interfacial reaction in the nanometer-scale metallic multilayers.

  13. Comparative and complementary characterization of precipitate microstructures in Al-Mg-Si(-Li) alloys by transmission electron microscopy, energy dispersive X-ray spectroscopy and atom probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koshino, Yuki [Department of Mechanical Engineering and Materials Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501 (Japan); Kozuka, Masaya [Materials Research Laboratory, Kobe Steel, Ltd., 1-5-5 Takatsukadai, Nishi-ku, Kobe 651-2271 (Japan); Hirosawa, Shoichi, E-mail: hirosawa@ynu.ac.jp [Department of Mechanical Engineering and Materials Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501 (Japan); Aruga, Yasuhiro [Materials Research Laboratory, Kobe Steel, Ltd., 1-5-5 Takatsukadai, Nishi-ku, Kobe 651-2271 (Japan)

    2015-02-15

    Highlights: • Microalloying addition of Li enhances the age-hardening response of Al-Mg-Si alloys. • Size and number density of nanoclusters or precipitates are increased by Li addition. • Mg and Si contents within the aggregates are inversely decreased by Li addition. • Microalloying Li accelerates heterogeneous nucleation of such Mg-Si aggregates. - Abstract: In this study, comparative and complementary characterization of precipitate microstructures by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS) and atom probe tomography (APT) has been performed for Al-0.55 wt%Mg-0.89 wt%Si(-0.043 wt%Li) alloys aged at 433 K for 1.2 ks (under aging) and 36 ks (peak aging). Quantitative estimation of nanometer-scale clusters (nanoclusters) and β″ precipitates by TEM and APT revealed that microalloying addition of Li increases the size and number density of these Mg-Si aggregates, resulting in the enhanced age-hardening response. Positive evidence by APT for the segregation of Li suggests that heterogeneous nucleation of such Mg-Si aggregates with the aid of Li is attributed to the modified precipitate microstructures and thus improved mechanical strength of this alloy system.

  14. Characterization of CuCl quantum dots grown in NaCl single crystals via optical measurements, X-ray diffraction, and transmission electron microscopy

    Science.gov (United States)

    Miyajima, Kensuke; Akatsu, Tatsuro; Itoh, Ken

    2018-05-01

    We evaluated the crystal size, shape, and alignment of the lattice planes of CuCl quantum dots (QDs) embedded in NaCl single crystals by optical measurements, X-ray diffraction (XRD) patterns, and transmission electron microscopy (TEM). We obtained, for the first time, an XRD pattern and TEM images for CuCl QDs in NaCl crystals. The XRD pattern showed that the lattice planes of the CuCl QDs were parallel to those of the NaCl crystals. In addition, the size of the QDs was estimated from the diffraction width. It was apparent from the TEM images that almost all CuCl QDs were polygonal, although some cubic QDs were present. The mean size and size distribution of the QDs were also obtained. The dot size obtained from optical measurements, XRD, and TEM image were almost consistent. Our new findings can help to reveal the growth mechanism of semiconductor QDs embedded in a crystallite matrix. In addition, this work will play an important role in progressing the study of optical phenomena originating from assembled semiconductor QDs.

  15. 3D membrane segmentation and quantification of intact thick cells using cryo soft X-ray transmission microscopy: A pilot study

    Science.gov (United States)

    Klementieva, Oxana; Werner, Stephan; Guttmann, Peter; Pratsch, Christoph; Cladera, Josep

    2017-01-01

    Structural analysis of biological membranes is important for understanding cell and sub-cellular organelle function as well as their interaction with the surrounding environment. Imaging of whole cells in three dimension at high spatial resolution remains a significant challenge, particularly for thick cells. Cryo-transmission soft X-ray microscopy (cryo-TXM) has recently gained popularity to image, in 3D, intact thick cells (∼10μm) with details of sub-cellular architecture and organization in near-native state. This paper reports a new tool to segment and quantify structural changes of biological membranes in 3D from cryo-TXM images by tracking an initial 2D contour along the third axis of the microscope, through a multi-scale ridge detection followed by an active contours-based model, with a subsequent refinement along the other two axes. A quantitative metric that assesses the grayscale profiles perpendicular to the membrane surfaces is introduced and shown to be linearly related to the membrane thickness. Our methodology has been validated on synthetic phantoms using realistic microscope properties and structure dimensions, as well as on real cryo-TXM data. Results demonstrate the validity of our algorithms for cryo-TXM data analysis. PMID:28376110

  16. An in situ cell to study phase transitions in individual aerosol particles on a substrate using scanning transmission x-ray microspectroscopy

    International Nuclear Information System (INIS)

    Huthwelker, T.; Zelenay, V.; Birrer, M.; Krepelova, A.; Raabe, J.; Ammann, M.; Tzvetkov, G.; Vernooij, M. G. C.

    2010-01-01

    A new in situ cell to study phase transitions and chemical processes on individual aerosol particles in the x-ray transmission microscope at the PolLux beamline of the Swiss light source has been built. The cell is machined from stainless steel and aluminum components and is designed to be used in the standard mount of the microscope without need of complicated rearrangements of the microscope. The cell consists of two parts, a back part which contains connections for the gas supply, heating, cooling devices, and temperature measurement. The second part is a removable clip, which hosts the sample. This clip can be easily exchanged and brought into a sampling unit for aerosol particles. Currently, the cell can be operated at temperatures ranging from -40 to +50 deg. C. The function of the cell is demonstrated using two systems of submicron size: inorganic sodium bromide aerosols and soot originating from a diesel passenger car. For the sodium bromide we demonstrate how phase transitions can be studied in these systems and that O1s spectra from aqueous sodium bromide solution can be taken from submicron sized particles. For the case of soot, we demonstrate that the uptake of water onto individual soot particles can be studied.

  17. Different X-ray spectral evolution for black hole X-ray binaries in dual tracks of radio-X-ray correlation

    International Nuclear Information System (INIS)

    Cao, Xiao-Feng; Wu, Qingwen; Dong, Ai-Jun

    2014-01-01

    Recently, an 'outlier' track of radio-X-ray correlation was found, which is much steeper than the former universal correlation, where dual tracks were speculated to be triggered by different accretion processes. In this work, we test this issue by exploring hard X-ray spectral evolution in four black-hole X-ray binaries with multiple, quasi-simultaneous radio and X-ray observations. First, we find that hard X-ray photon indices, Γ, are negatively and positively correlated with X-ray fluxes when the X-ray flux, F 3-9 keV , is below and above a critical flux, F X, crit , which are consistent with predictions of the advection-dominated accretion flow and the disk-corona model, respectively. Second, and most importantly, we find that the radio-X-ray correlations are also clearly different when the X-ray fluxes are higher and lower than the critical flux as defined by X-ray spectral evolution. The data points with F 3-9 keV ≳ F X, crit have a steeper radio-X-ray correlation (F X ∝F R b and b ∼ 1.1-1.4), which roughly forms the ''outlier'' track. However, the data points with anti-correlation of Γ – F 3-9 keV either stay in the universal track with b ∼ 0.61 or stay in the transition track (from the universal to 'outlier' tracks or vice versa). Therefore, our results support that the universal and ''outlier'' tracks of radio-X-ray correlations are regulated by radiatively inefficient and radiatively efficient accretion model, respectively.

  18. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  19. X-ray metrology for ULSI structures

    International Nuclear Information System (INIS)

    Bowen, D. K.; Matney, K. M.; Wormington, M.

    1998-01-01

    Non-destructive X-ray metrological methods are discussed for application to both process development and process control of ULSI structures. X-ray methods can (a) detect the unacceptable levels of internal defects generated by RTA processes in large wafers, (b) accurately measure the thickness and roughness of layers between 1 and 1000 nm thick and (c) can monitor parameters such as crystallographic texture and the roughness of buried interfaces. In this paper we review transmission X-ray topography, thin film texture measurement, grazing-incidence X-ray reflectivity and high-resolution X-ray diffraction. We discuss in particular their suitability as on-line sensors for process control

  20. Electrical interface characteristics (I-V), optical time of flight measurements, and the x-ray (20 keV) signal response of amorphous-selenium/crystalline-silicon heterojunction structures

    Science.gov (United States)

    Hunter, David M.; Ho, Chu An; Belev, George; De Crescenzo, Giovanni; Kasap, Safa O.; Yaffe, Martin J.

    2011-03-01

    We have investigated the dark current, optical TOF (time of flight) properties, and the X-ray response of amorphousselenium (a-Se)/crystalline-silicon (c-Si) heterostructures for application in digital radiography. The structures have been studied to determine if an x-ray generated electron signal, created in an a-Se layer, could be directly transferred to a c-Si based readout device such as a back-thinned CCD (charge coupled device). A simple first order band-theory of the structure indicates that x-ray generated electrons should transfer from the a-Se to the c-Si, while hole transfer from p-doped c-Si to the a-Se should be blocked, permitting a low dark signal as required. The structures we have tested have a thin metal bias electrode on the x-ray facing side of the a-Se which is deposited on the c-Si substrate. The heterostructures made with pure a-Se deposited on epitaxial p-doped (5×10 14 cm-3) c-Si exhibited very low dark current of 15 pA cm-2 at a negative bias field of 10 V μm-1 applied to the a-Se. The optical TOF (time of flight) measurements show that the applied bias drops almost entirely across the a-Se layer and that the a-Se hole and electron mobilities are within the range of commonly accepted values. The x-ray signal measurements demonstrate the structure has the expected x-ray quantum efficiency. We have made a back-thinned CCD coated with a-Se and although most areas of the device show a poor x-ray response, it does contain small regions which do work properly with the expected x-ray sensitivity. Improved understanding of the a-Se/c-Si interface and preparation methods should lead to properly functioning devices.

  1. Evolution and change of He bubbles in He-containing Ti films upon thermal treatment studied by small-angle X-ray scattering and transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Guangai [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Wu, Erdong, E-mail: ewu@imr.ac.cn [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Huang, Chaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Cheng, Chun [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Yan, Guanyun [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Wang, Xiaolin [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Liu, Shi [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Tian, Qiang; Chen, Bo [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Wu, Zhonghua [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Liu, Yi; Wang, Jie [Institute of Shanghai Apply Physics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2014-05-02

    Evolution and change of He bubbles in magnetron sputtering prepared He-containing Ti films under thermal treatment are studied by small-angle X-ray scattering (SAXS), transmission electron microscopy (TEM) and X-ray diffraction. Incorporation of He introduces a large number of He-vacancy clusters and some voids in the films, and significantly increases SAXS intensity and causes anisotropic scattering. The change of He induced defects during annealing is affected by thermal diffusion and migration of trapped He to the surface and between interfaces of He induced defects within the films. Annealing at 200 and 400 °C reduces intensity and anisotropy of SAXS, in accord with observed shrinking and disappearance of the voids. The simultaneous growth of non-uniformly distributed He bubbles to the sizes of 1–2 nm and a population level of 10{sup 5}/μm{sup 3} are detected in the temperature range. The changes are explained by migration and coalescence mechanisms, which requires low apparent activation energy. Inconsistence between TEM and SAXS observations is noted and attributed to thinning induced internal stress relaxation of TEM specimen. Remarkable enlargement of He bubbles, associated with increased SAXS intensity and fractal dimension, is observed after 600 °C annealing, indicating involvement of Ostwald Ripening (OR) mechanism. The OR process dominates at 800 °C, where the high temperature provides activation energy for accelerated He dissociation from small bubbles into larger ones, and generating textured microstructure and agglomerated bubble clusters. The inhomogeneous bubble size distribution observed at this temperature covers a broad range of about 10–50 nm and possessing a population density level of 10{sup 3}/μm{sup 3}. - Highlights: • Change of He bubbles in thermally treated Ti–He films is studied by SAXS and TEM. • SAXS reveals size distribution and fractional population of He bubbles in films. • He-vacancy clusters in Ti–He film

  2. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  3. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  4. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  5. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  6. Application of low power X-ray tubes in geology

    International Nuclear Information System (INIS)

    Massalski, J.M.; Zaraska, W.

    1981-01-01

    Low power X-ray tubes with transmission anodes for X-ray fluorescence analysis with energy dispersion were elaborated. Paper contains experimental results of application of X-ray tubes in the apparatus for nondestructive measurements of the concentration of some elements in borehole cores. (author)

  7. Study of non-validity of mixture rule near K-absorption edges by X-ray spectrometric technique

    International Nuclear Information System (INIS)

    Sharanabasappa; Chitralekha, A.; Kerur, B.R.; Anilkumar, S.

    2012-01-01

    X-ray spectrometric technique has been described to determine the X-ray mass attenuation coefficient, μ/ρ, of X-rays employing HPGe X-ray detector and radioactive sources. The photon intensity is measured by gating the channel of the spectrometer at FWHM/photo peak. Using the technique the 'best value' values of μ/ρ were obtained for those thicknesses which lie in the transmission (T) range 0.5 ≥ T ≥ 0.02. Total attenuation cross sections for other elements and lead compounds were measured at photon energies from 17 to 88 keV to study the Bragg's additivity law near the absorption edge of the lead. The measured values of mass attenuation coefficient values are compared with theoretical values obtained using Winxcom (programme). This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 17-23%. (author)

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  10. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  12. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  14. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  15. Backscatter, anisotropy, and polarization of solar hard X-rays

    International Nuclear Information System (INIS)

    Bai, T.; Ramaty, R.

    1978-01-01

    Hard X-rays incident upon the photosphere with energies > or approx. =15 keV have high probabilities of backscatter due to Compton collisions with electrons. This effect has a strong influence on the spectrum, intensity, and polarization of solar hard X-rays - especially for anisotropic models in which the primary X-rays are emitted predominantly toward the photosphere. We have carried out a detailed study of X-ray backscatter, and we have investigated the interrelated problems of anisotropy, polarization, center-to-limb variation of the X-ray spectrum, and Compton backscatter in a coherent fashion. The results of this study are compared with observational data. Because of the large contribution from backscatter, for an anisotropic primary X-ray source which is due to bremsstrahlung of accelerated electrons moving predominantly down toward the photosphere, the observed X-ray flux around 30 keV does not depend significantly on the position of flare on the Sun. For such an anisotropic source, the X-ray spectrum observed in the 15-50 keV range becomes steeper with the increasing heliocentric angle of the flare. These results are compatible with the data. The degree of polarization of the sum of the primary and reflected X-rays with energies between about 15 and 30 keV can be very large for anisotropic primary X-ray sources, but it is less than about 4% for isotropic sources. We also discuss the characteristics of the brightness distribution of the X-ray albedo patch created by the Compton backscatter. The height and anisotropy of the primary hard X-ray source might be inferred from the study of the albedo patch

  16. High-energy X-ray observations of extragalactic objects

    International Nuclear Information System (INIS)

    Pietsch, W.; Reppin, C.; Truemper, J.; Voges, W.; Lewin, W.; Kendziorra, E.; Staubert, R.

    1981-01-01

    During a balloon flight from Alice Springs, Australia, six extragalactic sources which are known as potential X-ray sources have been observed in hard X-rays (E > 20 keV). We present X-ray spectra of 3C 273 and Cen-A as well as upper limits on 3C 120, MKN 509, NGC 5506, and MR 2251-178. (orig.)

  17. Hard X-ray techniques suitable for polymer experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bras, W; Goossens, H; Goderis, B, E-mail: Wim.Bras@esrf.fr [Netherlands Organisation for Scientific Research (NWO) (Netherlands); DUBBLE-ESRF, BP 220, F38043 Grenoble Cedex (France); Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Molecular and Nanomaterials, Chemistry Department, Catholic University of Leuven, Celestijnenlaan 200F (Belgium)

    2010-11-15

    Polymers have been studied since 1979 with 8-12 keV synchrotron radiation X-ray scattering methods and the number and sophistication of the experiments have rapidly grown ever since. More recently, new experimental techniques have been developed that use softer or harder X-rays in less conventional ways. This article provides a brief overview of the possibilities of hard X-ray techniques and indicates some areas that might gain from further developments.

  18. Hard X-ray techniques suitable for polymer experiments

    International Nuclear Information System (INIS)

    Bras, W; Goossens, H; Goderis, B

    2010-01-01

    Polymers have been studied since 1979 with 8-12 keV synchrotron radiation X-ray scattering methods and the number and sophistication of the experiments have rapidly grown ever since. More recently, new experimental techniques have been developed that use softer or harder X-rays in less conventional ways. This article provides a brief overview of the possibilities of hard X-ray techniques and indicates some areas that might gain from further developments.

  19. Calibration of high-dynamic-range, finite-resolution x-ray pulse-height spectrometers for extracting electron energy distribution data from the PFRC-2 device

    Science.gov (United States)

    Swanson, C.; Jandovitz, P.; Cohen, S. A.

    2017-10-01

    Knowledge of the full x-ray energy distribution function (XEDF) emitted from a plasma over a large dynamic range of energies can yield valuable insights about the electron energy distribution function (EEDF) of that plasma and the dynamic processes that create them. X-ray pulse height detectors such as Amptek's X-123 Fast SDD with Silicon Nitride window can detect x-rays in the range of 200eV to 100s of keV. However, extracting EEDF from this measurement requires precise knowledge of the detector's response function. This response function, including the energy scale calibration, the window transmission function, and the resolution function, can be measured directly. We describe measurements of this function from x-rays from a mono-energetic electron beam in a purpose-built gas-target x-ray tube. Large-Z effects such as line radiation, nuclear charge screening, and polarizational Bremsstrahlung are discussed.

  20. Development of x-ray laminography under an x-ray microscopic condition

    International Nuclear Information System (INIS)

    Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa; Suzuki, Yoshio; Yagi, Naoto

    2011-01-01

    An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.

  1. Controlling X-ray beam trajectory with a flexible hollow glass fibre

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Yoshihito, E-mail: yotanaka@riken.jp [RIKEN, 1-1-1 Kouto, Sayo-cho, Hyogo 679-5148 (Japan); Kwansei Gakuin University, Gakuen, Sanda, Hyogo 669-1337 (Japan); Nakatani, Takashi; Onitsuka, Rena [Kwansei Gakuin University, Gakuen, Sanda, Hyogo 669-1337 (Japan); Sawada, Kei [RIKEN, 1-1-1 Kouto, Sayo-cho, Hyogo 679-5148 (Japan); Takahashi, Isao [Kwansei Gakuin University, Gakuen, Sanda, Hyogo 669-1337 (Japan)

    2014-01-01

    X-ray beam trajectory control has been performed by using a 1.5 m-long flexible hollow glass fibre. A two-dimensional scan of a synchrotron radiation beam was demonstrated for X-ray absorption mapping. A metre-length flexible hollow glass fibre with 20 µm-bore and 1.5 mm-cladding diameters for transporting a synchrotron X-ray beam and controlling the trajectory has been examined. The large cladding diameter maintains a moderate curvature to satisfy the shallow glancing angle of total reflection. The observed transmission efficiency was more than 20% at 12.4 keV. As a demonstration, a wide-area scan of a synchrotron radiation beam was performed to identify the elements for a fixed metal film through its absorption spectra.

  2. Photoemission measurements for low energy x-ray detector applications

    International Nuclear Information System (INIS)

    Day, R.H.

    1981-01-01

    Photoemission has been studied for nearly 100 years as both a means of investigating quantum physics, and as a practical technique for transducing optical/x-ray photons into electrical currents. Numerous x-ray detection schemes, such as streak cameras and x-ray sensitive diodes, exploit this process because of its simplicity, adaptability, and speed. Recent emphasis on diagnostics for low temperature, high density, and short-lived, plasmas for inertial confinement fusion has stimulated interest in x-ray photoemission in the sub-kilovolt regime. In this paper, a review of x-ray photoemission measurements in the 50 eV to 10 keV x-ray region is given and the experimental techniques are reviewed. A semiempirical model of x-ray photoemission is discussed and compared to experimental measurements. Finally, examples of absolutely calibrated instruments are shown

  3. Hard X-ray detection of the black hole candidates 4U 1630-47 and IGR J17091-3624 up to 200 keV with INTEGRAL

    DEFF Research Database (Denmark)

    Bodaghee, A.; Kuulkers, E.; Tomsick, J. A.

    2012-01-01

    During monitoring observations of the Norma and Inner Perseus Arms (rev. 1209: 2012 Sept. 6 from 18:18:23 to 22:00:21 UTC), INTEGRAL-ISGRI revealed that the accreting black hole candidates 4U 1630-47 and IGR J17091-3624 have brightened in the hard X-rays. Mosaic images consisting of 12.6 ks worth...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... also be useful to help diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  6. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... June is Men's Health Month Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  14. Thermal x-rays from SN 1987A

    International Nuclear Information System (INIS)

    Nomoto, K.; Shigeyama, T.; Hayakawa, S.; Itoh, H.; Masai, K.

    1988-01-01

    The authors discuss how the x-ray spectrum of SN 1987A observed with the Ginga satellite may be explained by the ejecta-circumstellar matter collision model at photon energies below 15 keV. The harder x-rays may be ascribed to Compton degradation of the gamma-rays from 56 Co

  15. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  2. Simulation of X-ray irradiation on human hand

    International Nuclear Information System (INIS)

    Amaya, Fabiola; Montoya, Modesto

    2001-01-01

    Using the Monte Carlo code MCNP we simulate a human hand X-rays irradiation with radiodiagnostic energies to find the better range energy to make radiographs with the lowest dose and an optimal contrast. We calculate bone doses by considering a soft tissue - water - and calcium bone hand, which is irradiated with a million of X-rays photons from a punctual source. These photons are directed inside a conic angle on the hand. Afterwards, we simulate elements which normally compose bones (C, H, O, N, Mg, P, Ca, and S). We estimate bone dose considering: a) bone material (water, calcium and bone tissue); b) bone thickness (0.01; 0.1; 0.5; 1.0; 1.5 and 3.0 cm); and c) source-hand distance (30, 50, 70 and 90 cm). We calculate photon transmission percent through soft tissue and bone tissue and the statistics from the number of photons that reach the radiographic film after passing through soft tissue or bone tissue for our geometric configuration. We found that we can obtain a good image contrast by using X-rays with energies in the range of 20 to 40 keV. (author)

  3. Low energy x-ray spectrometer

    International Nuclear Information System (INIS)

    Woodruff, W.R.

    1981-01-01

    A subkilovolt spectrometer has been produced to permit high-energy-resolution, time-dependent x-ray intensity measurements. The diffracting element is a curved mica (d = 9.95A) crystal. To preclude higher order (n > 1) diffractions, a carbon x-ray mirror that reflects only photons with energies less than approx. 1.1 keV is utilized ahead of the diffracting element. The nominal energy range of interest is 800 to 900 eV. The diffracted photons are detected by a gold-surface photoelectric diode designed to have a very good frequency response, and whose current is recorded on an oscilloscope. A thin, aluminium light barrier is placed between the diffracting crystal and the photoelectric diode detector to keep any uv generated on or scattered by the crystal from illuminating the detector. High spectral energy resolution is provided by many photocathodes between 8- and 50-eV wide placed serially along the diffracted x-ray beam at the detector position. The spectrometer was calibrated for energy and energy dispersion using the Ni Lα 1 2 lines produced in the LLNL IONAC accelerator and in third order using a molybdenum target x-ray tube. For the latter calibration the carbon mirror was replaced by one surfaced with rhodium to raise the cut-off energy to about 3 keV. The carbon mirror reflection dependence on energy was measured using one of our Henke x-ray sources. The curved mica crystal diffraction efficiency was measured on our Low-Energy x-ray (LEX) machine. The spectrometer performs well although some changes in the way the x-ray mirror is held are desirable. 16 figures

  4. Sixa-silicon x-ray array

    International Nuclear Information System (INIS)

    Taylor, I.

    1995-01-01

    Full text: The Spectrum-X-Gamma (SRG) satellite is scheduled for launch in 1995-96. Mission objectives include broad and narrow band imaging spectroscopy over a wide range of energies from the EUV through hard X-rays with an emphasis on studying galactic and extragalactic X-ray sources. Timing and moderate resolution spectroscopy can be performed with the solid state spectrometer SIXA (Silicon X-Ray Array), placed on the focal plane of the SODART telescope with total effective area of 1150 cm 2 at 6 keV (for f = 8 in telescope). The detector consists of 19 circular Si(Li) pixels, each with an active diameter of 9.2 min and thickness of 3 min. A radiative cooler will be used to bring the detector to the proper operating temperature (120-130 K). The energy range 0.5-20 keV is divided into 1024 channels of 20 eV size. Photons can be recorded with 30 μs time resolution and 160-200 eV (1-7 keV) energy resolution. Potential observing programmes (for e.g. time-resolved Iron Kα line spectroscopy) include stellar coronae, cataclysmic variables and X-ray binaries; accretion discs and coronae of neutron stars and black hole candidates; supernova remnants, active galactic nuclei and clusters of galaxies. (author)

  5. X-ray fluorescence cross sections for K and L x rays of the elements

    International Nuclear Information System (INIS)

    Krause, M.O.; Nestor, C.W. Jr.; Sparks, C.J. Jr.; Ricci, E.

    1978-06-01

    X-ray fluorescence cross sections are calculated for the major x rays of the K series 5 less than or equal to Z less than or equal to 101, and the three L series 12 less than or equal to Z less than or equal to 101 in the energy range 1 to 200 keV. This calculation uses Scofield's theoretical partical photoionization cross sections, Krause's evaluation of fluorescence and Coster-Kronig yields, and Scofield's theoretical radiative rates. Values are presented in table and graph format, and an estimate of their accuracy is made. The following x rays are considered: Kα 1 , Kα 1 , 2 , Kβ 1 , Kβ 1 , 3 , Lα 1 , Lα 1 , 2 , Lβ 1 , Lβ 2 , 15 , Lβ 3 , Ll, Lγ 1 , Lγ 4 , and L 1 → L 2 , 3 . For use in x-ray fluorescence analysis, Kα and Lα fluorescence cross sections are presented at specific energies: TiK identical with 4.55 keV, CrK identical with 5.46 keV, CoK identical with 7.00 keV, CuK identical with 8.13 keV, MoKα identical with 17.44 keV, AgK identical with 22.5 keV, DyK identical with 47.0 keV, and 241 Am identical with 59.54 keV. Supplementary material includes fluorescence and Coster--Kronig yields, fractional radiative rates, fractional fluorescence yields, total L-shell fluorescence cross sections, fluorescence and Coster-Kronig yields in condensed matter, effective fluorescence yields, average L-shell fluorescence yield, L-subshell photoionization cross section ratios, and conversion factors from barns per atom to square centimeters per gram

  6. Picosecond chronography at x-ray wavelengths

    International Nuclear Information System (INIS)

    Bird, P.R.; Bradley, D.J.; Roddie, A.G.; Sibbett, W.; Key, M.H.; Lamb, M.J.; Lewis, C.L.S.

    1975-01-01

    An ultrafast streak camera for vacuum U-V to X-ray radiation is described. Preliminary measurements on laser-produced plasmas are presented with time resolution down to 150 psecs and space resolution down to 40μm for 1keV X-ray emission from a plasma generated by 2GW laser pulses focussed on a Cu target. High sensitivity and wide spectral bandwidth is due to front surface photoemission at oblique incidence. Time resolution capability of 40 psec and simultaneous spatial resolution down to a few microns is theoretically possible with this system. (author)

  7. Superconductive junctions for x-ray spectroscopy

    International Nuclear Information System (INIS)

    Grand, J.B. le; Bruijn, M.P.; Frericks, M.; Korte, P.A.J. de; Houwman, E.P.; Flokstra, J.

    1992-01-01

    Biasing of SIS-junctions for the purpose of high energy resolution x-ray detection is complicated by the presence of a DC Josephson current and AC Josephson current resonances, so that a large magnetic field is normally used for the suppression of these Josephson features. A transimpedance amplifier is proposed for biasing and signal amplification at low magnetic field. X-ray spectroscopy detectors for astronomy require a high detection efficiency in the 0.5-10 keV energy band and a reasonable (∼1 cm 2 ) detector area. Calculations on absorber-junctions combinations which might meet these requirements are presented. (author) 9 refs.; 10 figs

  8. Order-disorder phase transformations in quaternary pyrochlore oxide system: Investigated by X-ray diffraction, transmission electron microscopy and Raman spectroscopic techniques

    International Nuclear Information System (INIS)

    Radhakrishnan, A.N.; Prabhakar Rao, P.; Sibi, K.S.; Deepa, M.; Koshy, Peter

    2009-01-01

    Order-disorder transformations in a quaternary pyrochlore oxide system, Ca-Y-Zr-Ta-O, were studied by powder X-ray diffraction (XRD) method, transmission electron microscope (TEM) and FT-NIR Raman spectroscopic techniques. The solid solutions in different ratios, 4:1, 2:1, 1:1, 1:2, 1:4, 1:6, of CaTaO 3.5 and YZrO 3.5 were prepared by the conventional high temperature ceramic route. The XRD results and Rietveld analysis revealed that the crystal structure changed from an ordered pyrochlore structure to a disordered defect fluorite structure as the ratios of the solid solutions of CaTaO 3.5 and YZrO 3.5 were changed from 4:1 to 1:4. This structural transformation in the present system is attributed to the lowering of the average cation radius ratio, r A /r B as a result of progressive and simultaneous substitution of larger cation Ca 2+ for Y 3+ at A sites and smaller cation Ta 5+ for Zr 4+ at B sites. Raman spectroscopy and TEM analysis corroborated the XRD results. - Graphical abstract: Selected area electron diffraction (SAED) patterns showed highly ordered diffraction maxima with characteristic superlattice weak diffraction spots of the pyrochlore structure for (a) Ca 0.6 7Y 1.33 Zr 1.33 Ta 0.33 O 7 (C2YZT2) and bright diffraction maxima arranged in a ring pattern of the fluorite structure for (b) Ca 0.29 7Y 1.71 Zr 1.71 Ta 0.29 O 7 (CY6Z6T).

  9. Effect of polymers on the nanostructure and on the carbonation of calcium silicate hydrates: a scanning transmission X-ray microscopy study

    KAUST Repository

    Ha, J.

    2011-09-07

    This study investigated the effects of organic polymers (polyethylene glycol and hexadecyltrimethylammonium) on structures of calcium silicate hydrates (C-S-H) which is the major product of Portland cement hydration. Increased surface areas and expansion of layers were observed for all organic polymer modified C-S-H. The results from attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopic measurements also suggest lowered water contents in the layered structures for the C-S-H samples that are modified by organic polymers. Scanning transmission X-ray microscopy (STXM) results further supports this observation. We also observed difference in the extent of C-S-H carbonation due to the presence of organic polymers. No calcite formed in the presence of HDTMA whereas formation of calcite was observed with C-S-H sample modified with PEG. We suggest that the difference in the carbonation reaction is possibly due to the ease of penetration and diffusion of the CO 2. This observation suggests that CO 2 reaction strongly depends on the presence of organic polymers and the types of organic polymers incorporated within the C-S-H structure. This is the first comprehensive study using STXM to quantitatively characterize the level of heterogeneity in cementitious materials at high spatial and spectral resolutions. The results from BET, XRD, ATR-FTIR, and STXM measurements are consistent and suggest that C-S-H layer structures are significantly modified due to the presence of organic polymers, and that the chemical composition and structural differences among the organic polymers determine the extent of the changes in the C-S-H nanostructures as well as the extent of carbonation reaction. © 2011 Springer Science+Business Media, LLC.

  10. Structure determination of chitosan-stabilized Pt and Pd based bimetallic nanoparticles by X-ray photoelectron spectroscopy and transmission electron microscopy

    International Nuclear Information System (INIS)

    Wu, Lihua; Shafii, Salimah; Nordin, Mohd Ridzuan; Liew, Kong Yong; Li, Jinlin

    2012-01-01

    Chitosan (CTS)-stabilized bimetallic nanoparticles were prepared at room temperature (rt.) in aqueous solution. Palladium (Pd) and platinum (Pt) were selected as the first metals while iron (Fe) and nickel (Ni) functioned as the second metals. In order to obtain the noble metal core-transition metal shell structures, bimetallic nanoparticles were prepared in a two-step process: the preparation of mono noble metallic (Pd or Pt) nanoparticles and the deposition of transition metals (Fe or Ni) on the surface of the monometallic nanoparticles. The structures of the nanoparticles were studied using X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The XPS results show that Pd and Pt exist mainly in zero valences. The presence of Fe and Ni in the bimetallic nanoparticles affects the binding energy of Pd and Pt. Moreover, the studies of O 1s spectra indicate the presence of Fe or Ni shells. The analyses of TEM micrographs give the particle size and size distributions while the high-resolution TEM (HRTEM) micrographs show the existence of noble metal core lattices. The results confirm the formation of noble metal core-transition metal shell structures. -- Highlights: ► Chitosan-stabilized bimetallic nanoparticles were prepared at room temperature in aqueous solution. ► The presence of Fe or Ni shells was proven by XPS study. ► The existence of noble metal cores covered by amorphous shells was indicated by TEM study. ► The formation of noble metal core-transition metal shell structures was confirmed.

  11. NuSTAR Hard X-ray Survey of the Galactic Center Region. I. Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    DEFF Research Database (Denmark)

    Mori, Kaya; Hailey, Charles J.; Krivonos, Roman

    2015-01-01

    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources, and a previously unknown central component of hard X-ray emission (CHXE). Nu...

  12. NuSTAR Hard X-Ray Survey of the Galactic Center Region. II. X-Ray Point Sources

    DEFF Research Database (Denmark)

    Hong, JaeSub; Mori, Kaya; Hailey, Charles J.

    2016-01-01

    persistent luminous X-ray binaries (XBs) and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr. A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra...

  13. Design studies for ITER x-ray diagnostics

    International Nuclear Information System (INIS)

    Hill, K.W.; Bitter, M.; von Goeler, S.; Hsuan, H.

    1995-01-01

    Concepts for adapting conventional tokamak x-ray diagnostics to the harsh radiation environment of ITER include use of grazing-incidence (GI) x-ray mirrors or man-made Bragg multilayer (ML) elements to remove the x-ray beam from the neutron beam, or use of bundles of glass-capillary x-ray ''light pipes'' embedded in radiation shields to reduce the neutron/gamma-ray fluxes onto the detectors while maintaining usable x-ray throughput. The x-ray optical element with the broadest bandwidth and highest throughput, the GI mirror, can provide adequate lateral deflection (10 cm for a deflected-path length of 8 m) at x-ray energies up to 12, 22, or 30 keV for one, two, or three deflections, respectively. This element can be used with the broad band, high intensity x-ray imaging system (XIS), the pulseheight analysis (PHA) survey spectrometer, or the high resolution Johann x-ray crystal spectrometer (XCS), which is used for ion-temperature measurement. The ML mirrors can isolate the detector from the neutron beam with a single deflection for energies up to 50 keV, but have much narrower bandwidth and lower x-ray power throughput than do the GI mirrors; they are unsuitable for use with the XIS or PHA, but they could be used with the XCS; in particular, these deflectors could be used between ITER and the biological shield to avoid direct plasma neutron streaming through the biological shield. Graded-d ML mirrors have good reflectivity from 20 to 70 keV, but still at grazing angles (<3 mrad). The efficiency at 70 keV for double reflection (10 percent), as required for adequate separation of the x-ray and neutron beams, is high enough for PHA requirements, but not for the XIS. Further optimization may be possible

  14. Fabrication techniques of X-ray spiral zone plates

    International Nuclear Information System (INIS)

    Gao Nan; Zhu Xiaoli; Li Hailiang; Xie Changqing

    2010-01-01

    The techniques to make X-ray spiral zone plates using electron beam and X-ray lithography were studied. A master mask was fabricated on polyimide membrane by E-beam lithography and micro-electroplating. Spiral zone plates were efficiently replicated by X-ray lithography and micro-electroplating. By combining the techniques, spiral zone plates at 1 keV were successfully fabricate. With an outermost zone width of the 200 nm, and the gold absorbers thickness of 700 nm, the high quality zone plates can be used for X-ray phase contrast microscopy.(authors)

  15. Quantitative analysis with energy dispersive X-ray fluorescence analyser

    International Nuclear Information System (INIS)

    Kataria, S.K.; Kapoor, S.S.; Lal, M.; Rao, B.V.N.

    1977-01-01

    Quantitative analysis of samples using radioisotope excited energy dispersive x-ray fluorescence system is described. The complete set-up is built around a locally made Si(Li) detector x-ray spectrometer with an energy resolution of 220 eV at 5.94 KeV. The photopeaks observed in the x-ray fluorescence spectra are fitted with a Gaussian function and the intensities of the characteristic x-ray lines are extracted, which in turn are used for calculating the elemental concentrations. The results for a few typical cases are presented. (author)

  16. Development of real-time x-ray microtomography system

    International Nuclear Information System (INIS)

    Takano, H; Morikawa, M; Konishi, S; Azuma, H; Shimomura, S; Tsusaka, Y; Kagoshima, Y; Nakano, S; Kosaka, N; Yamamoto, K

    2013-01-01

    We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a 'zoom resolution' procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 μm using 10 keV x-rays

  17. Start of Eta Car's X-ray Minimum

    Science.gov (United States)

    Corcoran, Michael F.; Liburd, Jamar; Hamaguchi, Kenji; Gull, Theodore; Madura, Thomas; Teodoro, Mairan; Moffat, Anthony; Richardson, Noel; Russell, Chris; Pollock, Andrew; hide

    2014-01-01

    Analysis of Eta Car's X-ray spectrum in the 2-10 keV band using quicklook data from the XRay Telescope on Swift shows that the flux on July 30, 2014 was 4.9 plus or minus 2.0×10(exp-12) ergs s(exp-1)cm(exp-2). This flux is nearly equal to the X-ray minimum flux seen by RXTE in 2009, 2003.5, and 1998, and indicates that Eta Car has reached its X-ray minimum, as expected based on the 2024-day period derived from previous 2-10 keV observations with RXTE.

  18. Fresnel zone-plate based X-ray microscopy in Zernike phase contrast with sub-50 nm resolution at NSRL

    Energy Technology Data Exchange (ETDEWEB)

    Chen Jie; Li Wenjie; Tian Jinping; Liu Longhua; Xiong Ying; Liu Gang; Wu Ziyu; Tian Yangchao [National Synchrotron Radiation Laboratory (China); Liu Yijin [School of Physics (China); Yue Zhengbo; Yu Hanqing [Laboratory of Environmental Engineering, School of Chemistry, University of Science and Technology of China, Hefei Anhui 230029 (China); Wang Chunru, E-mail: ychtian@ustc.edu.c [Institute of Chemistry, Chinese Academy of Sciences, Beijing 10060 (China)

    2009-09-01

    A transmission X-ray microscope using Fresnel zone-plates (FZPs) has been installed at U7A beamline of National Synchrotron Radiation Laboratory (NSRL). The objective FZP with 45 nm outermost zone width delivers a sub-50 nm resolution. A gold phase ring with 2.5 {mu}m thickness and 4 {mu}m width was placed at the focal plane of the objective FZP at 8 keV to produce a negative Zernike phase contrast. A series of samples were used to test the performance of the Zernike phase contrast X-ray microscopy.

  19. Fresnel zone-plate based X-ray microscopy in Zernike phase contrast with sub-50 nm resolution at NSRL

    International Nuclear Information System (INIS)

    Chen Jie; Li Wenjie; Tian Jinping; Liu Longhua; Xiong Ying; Liu Gang; Wu Ziyu; Tian Yangchao; Liu Yijin; Yue Zhengbo; Yu Hanqing; Wang Chunru

    2009-01-01

    A transmission X-ray microscope using Fresnel zone-plates (FZPs) has been installed at U7A beamline of National Synchrotron Radiation Laboratory (NSRL). The objective FZP with 45 nm outermost zone width delivers a sub-50 nm resolution. A gold phase ring with 2.5 μm thickness and 4 μm width was placed at the focal plane of the objective FZP at 8 keV to produce a negative Zernike phase contrast. A series of samples were used to test the performance of the Zernike phase contrast X-ray microscopy.

  20. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  1. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  2. The MEL-X project at the Lawrence Livermore National Laboratory: a mirror-based delay line for x-rays

    Science.gov (United States)

    Pardini, Tom; Hill, Randy; Decker, Todd; Alameda, Jennifer; Soufli, Regina; Aquila, Andy; Guillet, Serge; Boutet, Sébastien; Hau-Riege, Stefan P.

    2015-09-01

    At the Lawrence Livermore National Laboratory (LLNL) in collaboration with the Linac Coherent Light Source (LCLS) we are developing a mirror-based delay line for x-rays (MEL-X) to enable x-ray pump/x-ray probe experiments at Free Electron Lasers (XFELs). The goal of this project is the development and deployment of a proof-of-principle delay line featuring coated x-ray optics. The four-mirror design of the MEL-X is motivated by the need for ease of alignment and use. In order to simplify the overlap of the pump and the probe beam after each delay time change, a scheme involving super-polished rails and mirror-to-motor decoupling has been adopted. The MEL-X, used in combination with a bright pulsed source like LCLS, features a capability for a high intensity pump beam. Its Iridium coating allows it to work at hard x-ray energies all the way up to 9 keV, with a probe beam transmission of 35% up to 8keV, and 14% at 9keV. The delay time can be tailored to each particular experiment, with a nominal range of 70 - 350 fs for this prototype. The MEL-X, combined with established techniques such as x-ray diffraction, absorption or emission, could provide new insights on ultra-fast transitions in highly excited states of matter.

  3. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...... in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all...

  4. Half a century of cosmic x-ray research

    International Nuclear Information System (INIS)

    Makishima, Kazuo; Takahashi, Tadayuki

    2012-01-01

    The year of 2012, which is the centennial of the cosmic-ray discovery, happens to coincide with the 50th anniversary of the discovery of cosmic X-ray sources. First carried by cosmic-ray physicists, the study of cosmic X-rays has made explosive developments over the last half a century, and has established the X-ray wavelength as an indispensable window onto the Universe. Among a variety of X-ray emitting celestial objects, we choose here neutron stars as a representative, and review the 50 years connecting the dawn era of the research and the state-of-the-art ASTRO-H satellite to be launched in 2014. In this article, 'X-rays' mean energetic photons with energies from 0.1 keV up to a few hundreds keV. (author)

  5. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  6. X-ray astronomy

    International Nuclear Information System (INIS)

    Narayanan, M.S.

    1976-01-01

    The deployment of detectors outside the deleterious effects of the atmosphere by sending them in space vehicles, has been explained. This has thrown open the entire spectrum of the electromagnetic and particle radiation to direct observations, thus enlarging the vistas of the field of astronomy and astrophysics. The discovery of strong emitters of X-rays such as SCO X-1, NorX-2, transient sources such as Cen X-2, Cen X-4, Cen X-1, Supernova remnants Tan X-1, etc., are reported. The background of the X-ray spectrum as measured during two rocket flights over Thumba, India is presented. (K.B.)

  7. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  8. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  9. The superconducting high-resolution soft X-ray spectrometer at the advanced biological and environmental X-ray facility

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, S. [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-188, Livermore, CA 94550 (United States); Advanced Biological and Environmental X-ray Facility, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 6-2100, Berkeley, CA 94720 (United States)], E-mail: Friedrich1@llnl.gov; Drury, O.B. [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-188, Livermore, CA 94550 (United States); Advanced Biological and Environmental X-ray Facility, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 6-2100, Berkeley, CA 94720 (United States); Biophysics Group, University of California, 1 Shields Avenue, EU-III, Davis, CA 95616 (United States); George, S.J. [Advanced Biological and Environmental X-ray Facility, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 6-2100, Berkeley, CA 94720 (United States); Cramer, S.P. [Advanced Biological and Environmental X-ray Facility, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 6-2100, Berkeley, CA 94720 (United States); Biophysics Group, University of California, 1 Shields Avenue, EU-III, Davis, CA 95616 (United States)

    2007-11-11

    We have built a 36-pixel superconducting tunnel junction X-ray spectrometer for chemical analysis of dilute samples in the soft X-ray band. It offers an energy resolution of {approx}10-20 eV FWHM below 1 keV, a solid angle coverage of {approx}10{sup -3}, and can be operated at total rates of up to {approx}10{sup 6} counts/s. Here, we describe the spectrometer performance in speciation measurements by fluorescence-detected X-ray absorption spectroscopy at the Advanced Biological and Environmental X-ray facility at the ALS synchrotron.

  10. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  11. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  12. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  13. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  14. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  15. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  16. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  17. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  18. Medical X-ray sources now and for the future

    Science.gov (United States)

    Behling, Rolf

    2017-11-01

    This paper focuses on the use of X-rays in their largest field of application: medical diagnostic imaging and image-guided therapy. For this purpose, vacuum electronics in the form of X-ray tubes as the source of bremsstrahlung (braking radiation) have been the number one choice for X-ray production in the range of photon energies between about 16 keV for mammography and 150 keV for general radiography. Soft tissue on one end and bony structures on the other are sufficiently transparent and the contrast delivered by difference of absorption is sufficiently high for this spectral range. The dominance of X-ray tubes holds even more than 120 years after Conrad Roentgen's discovery of the bremsstrahlung mechanism. What are the specifics of current X-ray tubes and their medical diagnostic applications? How may the next available technology at or beyond the horizon look like? Can we hope for substantial game changers? Will flat panel sources, less expensive X-ray "LED's", compact X-ray Lasers, compact synchrotrons or equivalent X-ray sources appear in medical diagnostic imaging soon? After discussing the various modalities of imaging systems and their sources of radiation, this overview will briefly touch on the physics of bremsstrahlung generation, key characteristics of X-ray tubes, and material boundary conditions, which restrict performance. It will discuss the deficits of the bremsstrahlung technology and try to sketch future alternatives and their prospects of implementation in medical diagnostics.

  19. Diagnostic X-ray sources-present and future

    Science.gov (United States)

    Behling, Rolf; Grüner, Florian

    2018-01-01

    This paper compares very different physical principles of X-ray production to spur ideation. Since more than 120 years, bremsstrahlung from X-ray tubes has been the workhorse of medical diagnostics. Generated by X-ray segments comprised of X-ray tubes and high-voltage generators in the various medical systems, X-ray photons in the spectral range between about 16 keV and 150 keV deliver information about anatomy and function of human patients and in pre-clinical animal studies. Despite of strides to employ the wave nature of X-rays as phase sensitive means, commercial diagnostic X-ray systems available until the time of writing still rely exclusively on measuring the attenuation and scattering of X-rays by matter. Significant activities in research aim at building highly brilliant short pulse X-ray sources, based on e.g. synchrotron radiation, free electron lasers and/or laser wake-field acceleration of electrons followed by wiggling with magnetic structures or Thomson scattering in bunches of light. While both approaches, non-brilliant and brilliant sources, have different scope of application, we speculate that a combination may expand the efficacy in medical application. At this point, however, severe technical and commercial difficulties hinder closing this gap. This article may inspire further development and spark innovation in this important field.

  20. Discovery of Hard Nonthermal Pulsed X-Ray Emission from the Anomalous X-Ray Pulsar 1E 1841-045

    NARCIS (Netherlands)

    Kuiper, L.; Hermsen, W.; Méndez, R.M.

    2004-01-01

    We report the discovery of nonthermal pulsed X-ray/soft gamma-ray emission up to ~150 keV from the anomalous 11.8 s X-ray pulsar AXP 1E 1841-045 located near the center of supernova remnant Kes 73 using Rossi X-Ray Timing Explorer (RXTE) Proportional Counter Array and High Energy X-Ray Timing

  1. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  2. Joint European x-ray monitor (JEM-X): x-ray monitor for ESA's

    DEFF Research Database (Denmark)

    Schnopper, H.W.; Budtz-Joergensen, C.; Westergaard, Niels Jørgen Stenfeldt

    1996-01-01

    JEM-X will extend the energy range of the gamma ray instruments on ESA's INTEGRAL mission (SPI, IBIS) to include the x-ray band. JEM-X will provide images with arcminute angular resolution in the 2 - 60 keV band. The baseline photon detection system consists of two identical, high pressure, imagi...

  3. X-Ray Calorimeter Arrays for Astrophysics

    Science.gov (United States)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  4. Synchrotron radiation calibration for soft X-ray detector

    International Nuclear Information System (INIS)

    Ning, Jiamin; Guo, Cun; Xu, Rongkun; Jiang, Shilun; Xu, Zeping; Chen, Jinchuan; Xia, Guangxin; Xue, Feibiao; Qin, Yi

    2009-04-01

    The calibration experiments were carried out to X-ray film, scintillator and transmission grating by employing the soft X-ray station at 3W1B beam-line in Beijing synchrotron Radiation Facility. The experiments presented the black intensity curve and energy response curve of soft X-ray film. And the experimental results can be used in diagnosis of X-ray radiation characterization of Z-pinch, such as in the measurement of soft X-ray Power Meter, grating spectrometer, pinhole camera and one-dimension imaging system which can ensure precision of Z-pinch results. (authors)

  5. High-Resolution X-Ray Spectra of the Symbiotic Star SS73 17

    Science.gov (United States)

    Eze, R. N. C.; Luna, G. J. M.; Smith, R. K.

    2010-01-01

    SS73 17 was an innocuous Mira-type symbiotic star until the International Gamma-Ray Astrophysics Laboratory and Swift discovered its bright hard X-ray emission, adding it to the small class of "hard X-ray emitting symbiotics." Suzaku observations in 2006 then showed it emits three bright iron lines as well, with little to no emission in the 0.3-2.0 keV bandpass. We present here follow-up observations with the Chandra High Energy Transmission Grating and Suzaku that confirm the earlier detection of strong emission lines of Fe K(alpha) fluorescence, Fe XXV and Fe XXVI but also show significantly more soft X-ray emission. The high-resolution spectrum also shows emission lines of other highly ionized ions as Si xiv and possibly S XVI. In addition, a re-analysis of the 2006 Suzaku data using the latest calibration shows that the hard (15-50 keV) X-ray emission is brighter than previously thought and remains constant in both the 2006 and 2008 data. The G ratio calculated from the Fe xxv lines shows that these lines are thermal, not photoionized, in origin.With the exception of the hard X-ray emission, the spectra from both epochs can be fit using thermal radiation assuming a differential emission measure based on a cooling-flow model combined with a full and partial absorber. We show that acceptable fits can be obtained for all the data in the 1-10 keV band varying only the partial absorber. Based on the temperature and accretion rate, the thermal emission appears to be arising from the boundary layer between the accreting white dwarf and the accretion disk.

  6. HIGH-RESOLUTION X-RAY SPECTRA OF THE SYMBIOTIC STAR SS73 17

    International Nuclear Information System (INIS)

    Eze, R. N. C.; Luna, G. J. M.; Smith, R. K.

    2010-01-01

    SS73 17 was an innocuous Mira-type symbiotic star until the International Gamma-Ray Astrophysics Laboratory and Swift discovered its bright hard X-ray emission, adding it to the small class of 'hard X-ray emitting symbiotics'. Suzaku observations in 2006 then showed it emits three bright iron lines as well, with little to no emission in the 0.3-2.0 keV bandpass. We present here follow-up observations with the Chandra High Energy Transmission Grating and Suzaku that confirm the earlier detection of strong emission lines of Fe Kα fluorescence, Fe XXV and Fe XXVI but also show significantly more soft X-ray emission. The high-resolution spectrum also shows emission lines of other highly ionized ions as Si XIV and possibly S XVI. In addition, a re-analysis of the 2006 Suzaku data using the latest calibration shows that the hard (15-50 keV) X-ray emission is brighter than previously thought and remains constant in both the 2006 and 2008 data. The G ratio calculated from the Fe XXV lines shows that these lines are thermal, not photoionized, in origin. With the exception of the hard X-ray emission, the spectra from both epochs can be fit using thermal radiation assuming a differential emission measure based on a cooling-flow model combined with a full and partial absorber. We show that acceptable fits can be obtained for all the data in the 1-10 keV band varying only the partial absorber. Based on the temperature and accretion rate, the thermal emission appears to be arising from the boundary layer between the accreting white dwarf and the accretion disk.

  7. Micron-CT using quasi-monochromatic x-rays produced in micro-PIXE

    International Nuclear Information System (INIS)

    Ishii, K.

    2009-01-01

    In ion-atom collision, characteristic X-rays are intensively produced and can be considered as a monochromatic X-ray source. We apply this feature to X-ray CT. By using micro-beams, cross sectional images can be provided with a spatial resolution of about 1 μm. On the basis of this idea, we developed a micron-CT consisting of a micro-beam system and an X-ray CCD camera. A tube holding samples was rotated by a stepping motor and the transmission images of the sample were taken with characteristic K-X-rays of Ti (4.558 keV) produced by 3 MeV proton micro-beams. After image reconstruction, images of cross sections of small objects were obtained with a spatial resolution of 3 μm. Using an absorption edge, we can identify an element in a sample. It is expected that our micron-CT can provide cross sectional images of in-vivo cellular samples and can be applied to a wide range of researches in biology and medicine. (author)

  8. Ion beam induced surface graphitization of CVD diamond for x-ray beam position monitor applications

    International Nuclear Information System (INIS)

    Liu, Chian; Shu, D.; Kuzay, T.M.; Wen, L.; Melendres, C.A.; Argonne National Lab., IL

    1996-01-01

    The Advanced Photon Source at ANL is a third-generation synchrotron facility that generates powerful x-ray beams on its undulator beamlines. It is important to know the position and angle of the x- ray beam during experiments. Due to very high heat flux levels, several patented x-ray beam position monitors (XBPM) exploiting chemical vapor deposition (CVD) diamond have been developed. These XBPMs have a thin layer of low-atomic-mass metallic coating so that photoemission from the x rays generate a minute but measurable current for position determination. Graphitization of the CVD diamond surface creates a very thin, intrinsic and conducting layer that can stand much higher temperatures and minimal x-ray transmission losses compared to the coated metallic layers. In this paper, a laboratory sputter ion source was used to transform selected surfaces of a CVD diamond substrate into graphite. The effect of 1-5 keV argon ion bombardment on CVD diamond surfaces at various target temperatures from 200 to 500 C was studied using Auger electron spectroscopy and in-situ electrical resistivity measurements. Graphitization after the ion bombardment has been confirmed and optimum conditions for graphitization studied. Raman spectroscopy was used to identify the overall diamond structure in the bulk of CVD diamond substrate after the ion bombardments. It was found that target temperature plays an important role in stability and electrical conductivity of the irradiated CVD diamonds

  9. A phantom test of proton-induced dual-energy X-ray angiography using iodinated contrast media

    International Nuclear Information System (INIS)

    Oguri, Y.; Hasegawa, J.; Ogawa, M.; Kaneko, J.; Sasa, K.

    2007-01-01

    Characteristic-line radiation from heavy metal targets bombarded by MeV proton beams has been tested as an X-ray source for dual-energy K-edge subtraction imaging for human angiography (blood vessel imaging) based on iodinated contrast media. To utilize the strong absorption by iodine (Z=53) at its K-absorption edge (33.2 keV), we used K α -line of La (lanthanum, Z=57) at 33.4 keV. As a reference, also K α X emission of Sn (tin, Z=50) at 25.2 keV was employed. Metallic plates of La and Sn were irradiated by 7-MeV protons to produce these characteristic X-rays. Energy-subtraction method was tested using Lucite phantoms which contain aqueous solutions of KI (potassium iodide) with different concentrations. Also Ca(H 2 PO 4 ) 2 powder was stuffed in these phantoms to simulate bones. The transmission images of the phantoms were recorded on imaging plates. During the exposure, the energy spectra of the X-rays were monitored by a CdTe detector. We found that the contrast of images of iodide solutions taken with La X-rays was higher than that with Sn X-rays. Also the energy subtraction procedure was successfully applied to reduce the graphical noise due to the bones and inhomogeneity of the soft tissue. However, to apply the present method to actual clinical use, the X-ray intensity must be increased by several orders of magnitude. Also the transmission of the 'lower-energy' photons has to be a few orders higher for imaging of objects as thick as human chest. (author)

  10. Chest X-Ray

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  11. X-ray sources

    International Nuclear Information System (INIS)

    Bonse, U.

    1979-11-01

    The author describes several possibilities for the production of X-radiation. Especially he discusses the use of bremsstrahlung at electron impact on solid targets and the synchrotron radiation. He presents some equations for the calculation of X-ray intensities. Especially the X-radiation from the DORIS storage ring is discussed. (HSI)

  12. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... change into a gown. You may have some concerns about chest x-rays. However, it’s important to ... You Sponsored by About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  14. X-ray Microprobe for Fluorescence and Diffraction Analysis

    International Nuclear Information System (INIS)

    Ice, G.E.

    2005-01-01

    microdiffraction analysis techniques some of the most powerful techniques available for the nondestructive measurement of chemical and crystallographic distributions in materials. This unit reviews the physics, advantages, and scientific applications of hard x-ray (E > 3 keV) microfluorescence and x-ray microdiffraction analysis. Because practical x-ray microbeam instruments are extremely rare, a special emphasis will be placed on instrumentation, accessibility, and experimental needs which justify the use of x-ray microbeam analysis.

  15. X-Ray and Near-Infrared Spectroscopy of Dim X-Ray Point Sources Constituting the Galactic Ridge X-Ray Emission

    Directory of Open Access Journals (Sweden)

    Kumiko Morihana

    2014-12-01

    Full Text Available We present the results of X-ray and Near-Infrared observations of the Galactic Ridge X-ray Emission (GRXE. We extracted 2,002 X-ray point sources in the Chandra Bulge Field (l =0°.113, b = 1°.424 down to ~10-14.8 ergscm-2s-1 in 2-8 keV band with the longest observation (900 ks of the GRXE. Based on X-ray brightness and hardness, we classied the X-ray point sources into three groups: A (hard, B (soft and broad spectrum, and C (soft and peaked spectrum. In order to know populations of the X-ray point sources, we carried out NIR imaging and spectroscopy observation. We identied 11% of X-ray point sources with NIR and extracted NIR spectra for some of them. Based on X-ray and NIR properties, we concluded that non-thermal sources in the group A are mostly active galactic nuclei and the thermal sources are mostly white dwarf binaries such as cataclysmic variables (CVs and Pre-CVs. We concluded that the group B and C sources are X-ray active stars in flare and quiescence, respectively.

  16. X-ray irradiation of yeast cells

    Science.gov (United States)

    Masini, Alessandra; Batani, Dimitri; Previdi, Fabio; Conti, Aldo; Pisani, Francesca; Botto, Cesare; Bortolotto, Fulvia; Torsiello, Flavia; Turcu, I. C. Edmond; Allott, Ric M.; Lisi, Nicola; Milani, Marziale; Costato, Michele; Pozzi, Achille; Koenig, Michel

    1997-10-01

    Saccharomyces Cerevisiae yeast cells were irradiated using the soft X-ray laser-plasma source at Rutherford Laboratory. The aim was to produce a selective damage of enzyme metabolic activity at the wall and membrane level (responsible for fermentation) without interfering with respiration (taking place in mitochondria) and with nuclear and DNA activity. The source was calibrated by PIN diodes and X-ray spectrometers. Teflon stripes were chosen as targets for the UV laser, emitting X-rays at about 0.9 keV, characterized by a very large decay exponent in biological matter. X-ray doses to the different cell compartments were calculated following a Lambert-Bouguet-Beer law. After irradiation, the selective damage to metabolic activity at the membrane level was measured by monitoring CO2 production with pressure silicon detectors. Preliminary results gave evidence of pressure reduction for irradiated samples and non-linear response to doses. Also metabolic oscillations were evidenced in cell suspensions and it was shown that X-ray irradiation changed the oscillation frequency.

  17. Monte Carlo simulation of photon buildup factors for shielding materials in diagnostic x-ray facilities

    International Nuclear Information System (INIS)

    Kharrati, Hedi; Agrebi, Amel; Karoui, Mohamed Karim

    2012-01-01

    Purpose: A simulation of buildup factors for ordinary concrete, steel, lead, plate glass, lead glass, and gypsum wallboard in broad beam geometry for photons energies from 10 keV to 150 keV at 5 keV intervals is presented. Methods: Monte Carlo N-particle radiation transport computer code has been used to determine the buildup factors for the studied shielding materials. Results: An example concretizing the use of the obtained buildup factors data in computing the broad beam transmission for tube potentials at 70, 100, 120, and 140 kVp is given. The half value layer, the tenth value layer, and the equilibrium tenth value layer are calculated from the broad beam transmission for these tube potentials. Conclusions: The obtained values compared with those calculated from the published data show the ability of these data to predict shielding transmission curves. Therefore, the buildup factors data can be combined with primary, scatter, and leakage x-ray spectra to provide a computationally based solution to broad beam transmission for barriers in shielding x-ray facilities.

  18. Monte Carlo simulation of photon buildup factors for shielding materials in diagnostic x-ray facilities.

    Science.gov (United States)

    Kharrati, Hedi; Agrebi, Amel; Karoui, Mohamed Karim

    2012-10-01

    A simulation of buildup factors for ordinary concrete, steel, lead, plate glass, lead glass, and gypsum wallboard in broad beam geometry for photons energies from 10 keV to 150 keV at 5 keV intervals is presented. Monte Carlo N-particle radiation transport computer code has been used to determine the buildup factors for the studied shielding materials. An example concretizing the use of the obtained buildup factors data in computing the broad beam transmission for tube potentials at 70, 100, 120, and 140 kVp is given. The half value layer, the tenth value layer, and the equilibrium tenth value layer are calculated from the broad beam transmission for these tube potentials. The obtained values compared with those calculated from the published data show the ability of these data to predict shielding transmission curves. Therefore, the buildup factors data can be combined with primary, scatter, and leakage x-ray spectra to provide a computationally based solution to broad beam transmission for barriers in shielding x-ray facilities.

  19. Development of X-ray excitable luminescent probes for scanning X-ray microscopy

    International Nuclear Information System (INIS)

    Moronne, M.M.

    1999-01-01

    Transmission soft X-ray microscopy is now capable of achieving resolutions that are typically 5 times better than the best-visible light microscopes. With expected improvements in zone plate optics, an additional factor of two may be realized within the next few years. Despite the high resolution now available with X-ray microscopes and the high X-ray contrast provided by biological molecules in the soft X-ray region (λ=2-5 nm), molecular probes for localizing specific biological targets have been lacking. To circumvent this problem, X-ray excitable molecular probes are needed that can target unique biological features. In this paper we report our initial results on the development of lanthanide-based fluorescent probes for biological labeling. Using scanning luminescence X-ray microscopy (SLXM, Jacobsen et al., J. Microscopy 172 (1993) 121-129), we show that lanthanide organo-polychelate complexes are sufficiently bright and radiation resistant to be the basis of a new class of X-ray excitable molecular probes capable of providing at least a fivefold improvement in resolution over visible light microscopy. Lanthanide probes, able to bind 80-100 metal ions per molecule, were found to give strong luminescent signals with X-ray doses exceeding 10 8 Gy, and were used to label actin stress fibers and in vitro preparations of polymerized tubulin. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  20. Krypton K-shell X-ray spectra recorded by the HENEX spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J.F. [Naval Research Laboratory, Space Science Division, Washington DC 20375 (United States)]. E-mail: john.seely@nrl.navy.mil; Back, C.A. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Constantin, C. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Lee, R.W. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Chung, H.-K. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Hudson, L.T. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Szabo, C.I. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Henins, A. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Holland, G.E. [SFA Inc., 9315 Largo Drive West Suite 200, Largo MD 20774 (United States); Atkin, R. [Tiger Innovations, L.L.C., 3610 Vacation Lane, Arlington VA 22207 (United States); Marlin, L. [Naval Research Laboratory, Space Science Division, Washington DC 20375 (United States)

    2006-05-15

    High-resolution X-ray spectra were recorded by the High-Energy Electronic X-ray (HENEX) spectrometer from a variety of targets irradiated by the Omega laser at the Laboratory for Laser Energetics. The HENEX spectrometer utilizes four reflection crystals covering the 1-20keV energy range and one quartz(10-11) transmission crystal (Laue geometry) covering the 11-40keV range. The time-integrated spectral images were recorded on five CMOS X-ray detectors. In the spectra recorded from krypton-filled gasbag and hohlraum targets, the helium-like K-shell transitions n=1-2, 1-3, and 1-4 appeared in the 13-17keV energy range. A number of additional spectral features were observed at energies lower than the helium-like n=1-3 and n=1-4 transitions. Based on computational simulations of the spectra using the FLYCHK/FLYSPEC codes, which included opacity effects, these additional features are identified to be inner-shell transitions from the Li-like through N-like krypton charge states. The comparisons of the calculated and observed spectra indicate that these transitions are characteristic of the plasma conditions immediately after the laser pulse when the krypton density is 2x10{sup 18}cm{sup -3} and the electron temperature is in the range 2.8-3.2keV. These spectral features represent a new diagnostic for the charge state distribution, the density and electron temperature, and the plasma opacity. Laboratory experiments indicate that it is feasible to record K-shell spectra from gold and higher Z targets in the >60keV energy range using a Ge(220) transmission crystal.