WorldWideScience

Sample records for kaon beam line

  1. 1 to 2 GeV/c beam line for hypernuclear and kaon research

    Energy Technology Data Exchange (ETDEWEB)

    Chrien, R.E.

    1985-02-15

    A kaon beam line operating in the range from 1.0 to 2.0 GeV/c is proposed. The line is meant for kaon and pion research in a region hitherto inaccessible to experimenters. Topics in hypernuclear and kaon physics of high current interest include the investigation of doubly strange nuclear systems with the K/sup -/,K/sup +/ reaction, searching for dibaryon resonances, hyperon-nucleon interactions, hypernuclear ..gamma.. rays, and associated production of excited hypernuclei. The beam line would provide separated beams of momentum analyzed kaons at intensities greater than 10/sup 6/ particles per spill with a momentum determined to one part in a thousand. This intensity is an order of magnitude greater than that currently available. 63 references.

  2. Targets for a Neutral Kaon Beam

    Energy Technology Data Exchange (ETDEWEB)

    Keith, Christopher [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-04-01

    A secondary beam of neutral Kaons is under consideration for Hall D at Jefferson Lab to perform spectroscopic studies of hyperons produced by K 0 L particles scattering from proton and deuteron targets. The proposed physics program would utilize the GlueX detector package currently installed in Hall D. This contribution looks at potential targets for use in the new facility, paying close attention to the existing infrastructure of GlueX and Hall D. Unpolarized cryotargets of liquid hydrogen and deuerium, as well as polarized solid targets of protons and deuterons are examined.

  3. ENUBET: Enhanced NeUtrino BEams from kaon Tagging

    Science.gov (United States)

    Meregaglia, A.

    2016-12-01

    A reduction of the neutrino flux uncertainty by one order of magnitude in conventional neutrino beams can be achieved monitoring the positron production in the decay tunnel originating from the Ke3 decays of charged kaons. This novel approach will be developed in the framework of the ERC ENUBET Project. In this talk we present the aims of the project and the ongoing R&D for the instrumentation of the decay tunnel. In particular, we describe a specialized shashlik calorimeter (iron-scintillator) with a compact readout based on small-area silicon photo multipliers that allows for a very effective longitudinal segmentation of the detector to enhance electron/hadron separation. The expected performance of the detector estimated from a full GEANT4 simulation of the neutrino decay tunnel are presented. We also discuss preliminary results on a prototype composed by 12 ultra compact modules exposed to pions and electrons at CERN-PS.

  4. Eta Production from Hydrogen using Pion and Kaon Beams.

    Science.gov (United States)

    Tippens, W. Bradford

    1999-10-01

    Eta meson production data from pions and kaons near threshold are scarce and of poor quality. These data are important for determining the η n and ηΛ scattering lengths and for determining the role of resonances in the η production process. Both processes interestingly have dominant production resonances with masses very near the reaction threshold, which complicates the determination of the resonance parameters. Precision η production data from pions are needed to help resolve ambiguities in the determination of the resonance parameters of the N S_11 resonance and in the determination of the helicity amplitudes for η photoproduction. We report differential cross sections for η production near threshold from the reactions π^- p→ η n and K^- p→ ηΛ based upon data recently taken by the Crystal Ball Collaboration. Excitation functions and angular distributions will be presented. Angular distributions from both reactions show significant deviation from S-wave production.

  5. High energy beam lines

    Science.gov (United States)

    Marchetto, M.; Laxdal, R. E.

    2014-01-01

    The ISAC post accelerator comprises an RFQ, DTL and SC-linac. The high energy beam lines connect the linear accelerators as well as deliver the accelerated beams to two different experimental areas. The medium energy beam transport (MEBT) line connects the RFQ to the DTL. The high energy beam transport (HEBT) line connects the DTL to the ISAC-I experimental stations (DRAGON, TUDA-I, GPS). The DTL to superconducting beam (DSB) transport line connects the ISAC-I and ISAC-II linacs. The superconducting energy beam transport (SEBT) line connects the SC linac to the ISAC-II experimental station (TUDA-II, HERACLES, TIGRESS, EMMA and GPS). All these lines have the function of transporting and matching the beams to the downstream sections by manipulating the transverse and longitudinal phase space. They also contain diagnostic devices to measure the beam properties.

  6. Workshop on Physics with Neutral Kaon Beam at JLab (KL2016) Mini-Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Strakovsky, Igor I. [George Washington Univ., Washington, DC (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Amaryan, Moskov [Old Dominion Univ., Norfolk, VA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Chudakov, Eugene A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Meyer, Curtis A. [Carnegie Mellon Univ., Pittsburgh, PA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Pennington, Michael R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ritman, James L. [Forschungszentrum Juelich Institut fuer Kernphysik

    2016-05-01

    The KL2016 Workshop is following the Letter of Intent LoI12-15-001 "Physics Opportunities with Secondary KL beam at JLab" submitted to PAC43 with the main focus on the physics of excited hyperons produced by the Kaon beam on unpolarized and polarized targets with GlueX setup in Hall D. Such studies will broaden a physics program of hadron spectroscopy extending it to the strange sector. The Workshop was organized to get a feedback from the community to strengthen physics motivation of the LoI and prepare a full proposal.

  7. An rf separated kaon beam from the Main Injector: Superconducting aspects

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Edwards

    1998-11-01

    ThE report is intended to focus on the superconducting aspects of a potential separated kaon beam facility for the Main Injector, and most of this document reflects that emphasis. However, the RF features cannot be divorced from the overall beam requirements, and so the next section is devoted to the latter subject. The existing optics design that meets the needs of the two proposed experiments is outliied, and its layout at Fermilab is shown. The frequency and deflection gradient choices present implementation dMiculties, and the section closes with some commentary on these issues. Sec. 3 provides an introduction to cavity design considerations, and, in particular carries forward the discussion of resonator shape and frequency selection. The R&D program is the subject of Sec. 4. Provisional parameter choices will be summarized. Initial steps toward cavity fabrication based `on copper models have been taken. The next stages in cavity fabrication will be reviewed in some detail. The infrastructure needs and availability will be discussed. Sec. 5 discusses what maybe characterized as the in~edlents of a point design. At this writing, some aspects are clear and some are not. The basic systems are reasonably clear and are described. The final section presents a cost and schedule estimate for both the Ft&D and production phase. Some supporting material and elaboration is provided in the Appendices.

  8. Beam polarization asymmetry and the electromagnetic production of kaons from protons

    Science.gov (United States)

    Maxwell, Oren V.

    2012-12-01

    The beam polarization asymmetry in the reaction ep→e'K+Λ has been investigated in a tree-level effective Lagrangian model. The model incorporates most of the well-established baryon resonances with spins up to (5)/(2), four less well-established nucleon resonances with larger mass, and the two kaon resonances K(892) and K1(1270). The off-shell structure of the electromagnetic vertices was accounted for by the inclusion of electromagnetic form factors at those vertices. The free parameters of the model were fitted in a previous study to a large pool of photoproduction data from the CLAS, GRAAL, SAPHIR, and LEPS collaborations and to CLAS data for the virtual photoproduction structure functions σU, σT, σL, σTT, and σLT. Using this model, results were obtained for the beam polarization asymmetry structure function σLT' and compared with CLAS data. Two new fits to the combined photoproduction and electroproduction data with the σLT' data included were then generated. The first of these includes contributions from all of the resonances included in the previous study; the second excludes contributions from the N(2080) and N(2200) resonances. The results of both fits for both photoproduction and electroproduction observables are compared with the results of the previous fit and the data.

  9. Neutrino beam line optics study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ming-Jen

    1996-09-01

    A study was done to understand the beam line optics from the beginning of Switchyard all the way to the end of Neutrino beam line. All available SWIC data were taken to get the beam centroid and width to be used in the analysis. The beam emittance and lattice function at the beginning of beam line can also be inferred from the study. The result indicated that the normalized 95% emittance to be around 15 {pi}-mm-mr for the vertical plane and about 28 {pi}-mm-mr for the horizontal plane.

  10. RIA Fragmentation Line Beam Dumps

    Energy Technology Data Exchange (ETDEWEB)

    Stein, W

    2003-08-08

    The Rare Isotope Accelerator project involves generating heavy-element ion beams for use in a fragmentation target line to produce beams for physics research. The main beam, after passing through the fragmentation target, may be dumped into a beam dump located in the vacuum cavity of the first dipole magnet. For a dump beam power of 100 kW, cooling is required to avoid excessive high temperatures. The proposed dump design involves rotating cylinders to spread out the energy deposition and turbulent subcooled water flow through internal water cooling passages to obtain high, nonboiling, cooling rates.

  11. Beam line design using G4BeamLine

    CERN Document Server

    Dogan, Arda

    2014-01-01

    In Turkey in Ankara TAEK SANAEM Proton Accelerator Facility (PAF), there is a cyclotron which produces a focused intense 30 MeV proton beam and sends this beam to four different arms, three of which uses this beam to produce pharmaceutical medicine. The remaining one is spared for R&D purposes and the idea was to use these protons coming out from the fourth arm to use space radiation tests, which cannot be done in Turkey at the moment. However, according to SCC 25100 standards which is for 30 MeV protons, the beam coming out of cyclotron is too intense and focused to use for space radiation tests. Therefore, the main aim of my project is to design a beam line which will defocus the beam and reduce the flux so that the space radiation tests can be done according to the standards of SCC 25100.

  12. Beam and target dependencies of two-kaon femtoscopic correlations in SELEX

    Science.gov (United States)

    Nigmatkulov, Grigory

    2017-03-01

    The space and time extents of the particle emitting source created in collisions of particles with nuclei can be measured using a correlation femtoscopy method. In this paper we show the preliminary measurements of K± K± correlation functions in 600 GeV/c Σ-, π- and 540 GeV/c p interactions with carbon and copper nuclei. The one-dimensional correlation functions are parameterized by a Gaussian form. The dependencies of the charged kaon emitting source radii on the different h+A collisions are presented.

  13. Performance of the KTeV high-energy neutral kaon beam at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Bocean, V.

    1998-06-01

    The performance of the primary and secondary beams for the KTeV experiments E832 and E799-II is reviewed. The beam was commissioned in the summer of 1996 and initially operated for approximately one year. The report includes results on the primary beam, target station including primary beam dump and muon sweeping system, neutral beam collimation system, and alignment.

  14. Nonlinear optimization of beam lines

    CERN Document Server

    Tomás Garcia, Rogelio

    2006-01-01

    The current final focus systems of linear colliders have been designed based on the local compensation scheme proposed by P. Raimondi and A. Seryi [1]. However, there exist remaining aberrations that deteriorate the performance of the system. This paper develops a general algorithm for the optimization of beam lines based on the computation of the high orders of the transfer map using MAD-X [2] and PTC [3]. The algorithm is applied to the CLIC [4] Beam Delivery System (BDS).

  15. Kaon interferometry

    CERN Document Server

    Heinz, Ulrich W; Wiedemann, Urs Achim; Wu Yuang Fang

    1996-01-01

    Two-kaon and two-pion correlation functions for an expanding thermalized source are compared. In the Yano-Koonin-Podgoretskii parametrization of the correlation function, the HBT radius parameters are shown to obey M_\\bot- scaling in the absence of collective transverse flow. This scaling is broken by transverse flow. An accurate comparison of pion and kaon correlations can thus resolve issue whether the observed M_\\bot-dependence of the transverse radius parameter is due to transverse collective flow or other transverse gradients. Effects from resonance decays are shortly discussed.

  16. The Beam and Detector for the NA48 Neutral Kaon CP Violation Experiment at CERN

    CERN Document Server

    Fanti, V; Marras, D; Musa, L; Nappi, A; Batley, J Richard; Bevan, A; Dosanjh, R S; Galik, R; Gershon, T; Hay, B; Kalmus, George Ernest; Katvars, S; Lazzeroni, C; Moore, R; Munday, D J; Needham, M D; Olaiya, E; Parker, M A; Patel, M; Slater, M; Takach, S; White, T O; Wotton; Bal, F; Barr, G; Bocquet, G; Bremer, J; Brodier-Yourstone, P; Buchholz, P; Burns, M; Ceccucci, A; Clément, M; Cuhadar-Donzelsmann, T; Cundy, Donald C; Doble, Niels; Falaleev, V; Formenti, F; Funk, W; Gatignon, L; Gonidec, A; Grafström, P; Hallgren, B; Kapusta, P; Kesseler, G; Kubischta, Werner; Iwanski, W; Lacourt, A; Laverriere, G; Linser, G; Ljuslin, C; Marchioro, A; Mast, M; Matheys, J P; Morel, M; Norton, A; Orlic, J P; Panzer-Steindel, B; Schinzel, D; Seidl, W; Taureg, H; Tarlé, J C; Velasco, M; Vossnack, O; Wahl, H; Wertelaers, P; Weterings, J; Cheshkov, C; Gaponenko, A; Goudzovski, E; Khristov, P Z; Kalinin, A; Kekelidze, V D; Kozhevnikov, Yu; Madigozhin, D T; Molokanova, N A; Potrebenikov, Yu K; Tkatchev, A; Zinchenko, A I; Boyle, O; Knowles, I; Martin, V; Parsons, H; Peach, K J; Sacco, R; Veitch, E; Walker, A; Carassiti, V; Contalbrigo, M; Cotta-Ramusino, A; Dalpiaz, P; Damiani, C; Duclos, J; Ferretti, P; Frabetti, P L; Gianoli, A; Martini, M; Petrucci, F; Porcu, M; Rossi, F; Savrié, M; Scarpa, M; Simani, C; Bizzeti, A; Calvetti, M; Collazuol, G; Graziani, G; Iacopini, E; Lenti, M; Martelli, F; Michetti, A; Ruggiero, G; Veltri, M; Becker, H G; Behler, M; Blümer, H; Coward, D; Ebersberger, C; Eppard, K; Eppard, M; Fox, H; Geib, K H; Hirstius, A; Kalter, A; Kleinknecht, K; Koch, U; Köpke, L; Lopes da Silva, P; Luitz, S; Marouelli, P; Masetti, L; Melzer-Pellmann, I; Moosbrugger, U; Morales-Morales, C; Peters, A; Renk, B; Scheidt, J; Schmidt, J; Schmidt, S A; Schönharting, V; Schué, Yu; Staeck, J; Wanke, R; Wilhelm, R; Winhart, A; Wittgen, M; Zeitnitz, O; Dabrowski, A; Fonseca-Martin, T; Chollet, J C; Crépé, S; de La Taille, C; Fayard, L; Iconomidou-Fayard, L; Martin-Chassard, G; Ocariz, J; Unal, G; Wingerter-Seez, I; Anzivino, Giuseppina; Bordacchini, F; Cenci, P; Imbergamo, E; Lariccia, P; Lubrano, P; Mestvirishvili, A; Papi, A; Pepé, M; Piccini, M; Punturo, M; Talamonti, C; Tondini, F; Bertanza, L; Calafiura, P; Carosi, R; Casali, R; Cerri, C; Cirilli, M; Costantini, F; Fantechi, R; Fidecaro, Francesco; Fiorini, L; Giudici, S; Gorini, B; Laico, F; Lamanna, G; Mannelli, I; Marzulli, V; Passuello, D; Pierazzini, G M; Raffaelli, F; Sozzi, M; Tripiccione, R; Anvar, S; Bédérède, D; Bugeon, F; Chèze, J B; Cogan, J; De Beer, M; Debu, P; Durand, D; Edard, S; Fallou, J L; Formica, A; Gosset, L; Granier de Cassagnac, R; Heitzmann, J; Le Provost, H; Louis, F; Mandzhavidze, I; Mazzucato, E; Migliori, A; Mur, M; Peyaud, B; Schanne, S; Steinkamp, O; Tarte, Gérard; Turlay, René; Vallage, B; Holder, M; Augustin, I; Bender, M; Maier, A; Schwarz, I; Ziolkowski, M; Arcidiacono, R; Barberis, P L; Benotto, F; Bertolino, F; Biino, C; Brunasso, O; Cartiglia, N; Clemencic, M; Dattola, D; Goy-Lopez, S; Govi, G; Guida, R; Marchetto, F; Menichetti, E; Palestini, S; Pastrone, N; Chlopik, A; Guzik, Z; Nassalski, J P; Rondio, E; Szleper, M; Wislicki, W; Wronka, S; Dibon, Heinz; Fischer, G; Jeitler, Manfred; Markytan, Manfred; Mikulec, I; Neuhofer, G; Pernicka, M; Taurok, Anton; Widhalm, L

    2007-01-01

    The Beam and Detector, used for the NA48 experiment, devoted to the measurement of $Re(\\epsilon^{\\prime}/\\epsilon)$, and for the NA48/1 experiment on rare K_S and neutral hyperon decays, are described.

  17. MICRO-BUNCHING OF THE AGS SLOW EXTRACTED BEAM FOR A RARE KAON DECAY SEARCH.

    Energy Technology Data Exchange (ETDEWEB)

    GLENN,J.; SIVERTZ,M.; CHIANG,I.; LAZARUS,D.; KOSCIELNIAK,S.

    2001-06-18

    The AGS Slow Extracted Beam (SEB) must be chopped with 250 ps bursts every 40 ns to permit time-of-flight (ToF) measurement of the secondary K{sup 0} beam. Standard techniques to produce this level of bunching would require excessive rf voltage, thus we have developed a ''Micro-Bunching'' technique of extracting the beam as it is forced between empty rf buckets. A specification of the required rf system will be given. Four-dimensional model simulations of particle dynamics for the planned rf and extraction systems will be shown. Simulations of previous tests along with the test measurements are also presented. Measurement of tight bunching requires dedicated instrumentation. The design of a detector system to measure bunch widths and the extinction factor between bunches will be given; considerations include the various particles produced and transported, timing precision and background.

  18. The appearance of beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Carey, D.C.

    1993-05-01

    The combination of an existing graphics package with a large program like TRANSPORT has often resulted in considerable modification to the large program. Use of other graphics package has resulted in essentially having to repeat the work. This difficulty has been avoided in a modification of TRANSPORT which produce layouts of beam lines. Drawings of the reference trajectory and three-dimensional images of all magnets are made by the graphics package TOP DRAWER. Nothing specific to TOP DRAWER or any other graphics has been incorporated into TRANSPORT. If a user is with a different graphics package he or she can then begin usage of this alternate package essentially immediately.

  19. A new-concept calorimeter for future neutrino beams based on Kaon tagging

    Science.gov (United States)

    Longhin, A.; Ludovici, L.; Terranova, F.

    2016-07-01

    Neutrino cross-section measurements are an essential requirement for the next generation of neutrino oscillation experiments and they are presently limited by uncertainties on neutrino fluxes. In [1] we propose to instrument a neutrino decay tunnel to detect large angle positrons and tag the three-body semileptonic K+ →e+π0νe decays. In such a facility the absolute electron neutrino flux could be determined with unprecedented precision (O(1%)). An e+/π+ separation capability of about 2% as well as a high e+ efficiency is required for a diffuse particle source over a length of several tens of meters. Additional constraints, due to the harsh beam environment, involve radiation hardness and fast response. For this purpose we propose a specialized shashlik calorimeter (copper-scintillator) with a compact readout based on small-area Silicon PhotoMultipliers coupled to WLS fibers. The setup would allow an effective longitudinal segmentation for electron/hadron separation, reducing the dead zones introduced by fiber bundling. Detailed Monte Carlo simulations are in progress. The construction of a small prototype and exposures to pion and electron beams are foreseen.

  20. Beam line to S155

    CERN Multimedia

    1977-01-01

    The experiment S155 was designed by the Orsay (CSNM-CNRS) Collaboration to observe the properties of exotic light nuclei. It was installed in the PS neutrino tunnel. The photo shows a mass spectrometer (in the background) on line with the PS proton beam which arrives (bottom, right) from the fast extraction FE74. Roger Fergeau stands on the left. The alkaline isotopes produced in the carbon-uranium target heated at 2000°C were swiftly extracted, mass separated, and brought to a detector behind the shielding. Sodium 34 (11 protons and 23 neutrons) was observed and its half-life of only 5 ms was measured. The excited levels 2+ of Magnesium 30 and Magnesium 32 (Sodium descendants) were localised, and the magic number 20 was found to vanish. Thus, the discovery made earlier for Sodium 30 and Sodium 32, with the same apparatus, was confirmed. (See also photo 7706511.)

  1. BEAM TRANSPORT LINES FOR THE BSNS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI, J.

    2006-06-26

    This paper presents the design of two beam transport lines at the BSNS: one is the injection line from the Linac to the RCS and the other is the target line from the RCS to the target station. In the injection beam line, space charge effects, transverse halo collimation, momentum tail collimation and debunching are the main concerned topics. A new method of using triplet cells and stripping foils is used to collimate transverse halo. A long straight section is reserved for the future upgrading linac and debuncher. In the target beam line, large halo emittance, beam stability at the target due to kicker failures and beam jitters, shielding of back-scattering neutrons from the target are main concerned topics. Special bi-gap magnets will be used to reduce beam losses in the collimators in front of the target.

  2. Vortex-based line beam optical tweezers

    Science.gov (United States)

    Cheng, Shubo; Tao, Shaohua

    2016-10-01

    A vortex-based line beam, which has a straight-line shape of intensity and possesses phase gradient along the line trajectory is developed and applied for optical manipulation in this paper. The intensity and phase distributions of the beam in the imaging plane of the Fourier transform are analytically studied. Simulation results show that the length of the line and phase gradient possessed by a vortex-based line beam are dependent on the topological charge and the azimuthal proportional constant. A superposition of multiple phase-only holograms with elliptical azimuthal phases can be used to generate an array of vortex-based line beams. Optical trapping with the vortex-based line beams has been implemented. Furthermore, the automatic transportation of microparticles along the line trajectory perpendicular to the optical axis is realized with an array of the beams. The generation method for the vortex-based line beam is simple. The beam would have potential applications in fields such as optical trapping, laser machining, and so on.

  3. FFAG Beam Line for nuPIL - Neutrinos from PIon Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, Jean-Baptiste [Fermilab; Pasternak, Jaroslaw [Rutherford; Bross, Alan [Fermilab; Liu, Ao [Fermilab; Appleby, Robert [Cockcroft Inst. Accel. Sci. Tech.; Tygier, Sam [Cockcroft Inst. Accel. Sci. Tech.

    2016-06-01

    The Long Baseline Neutrino Facilities (LBNF) program aims to deliver a neutrino beam for the Deep Underground Neutrino Experiment (DUNE). The current baseline for LBNF is a conventional magnetic horn and decay pipe system. Neutrinos from PIon beam Line (nuPIL) is a part of the optimization effort to optimize the LBNF. It consists of a pion beam line after the horn to clean the beam of high energy protons and wrong-sign pions before transporting them into a decay beam line, where instrumentation could be implemented. This paper focuses on the FFAG solution for this pion beam line. The resulting neutrino flux is also presented.

  4. System-size and centrality dependence of charged kaon and pion production in nucleus-nucleus collisions at 40A GeV and 158A GeV beam energy

    NARCIS (Netherlands)

    Anticic, T.; Baatar, B.; Christakoglou, P.; van Leeuwen, M.; Wojtaszek-Szwarc, A.

    2012-01-01

    Measurements of charged pion and kaon production are presented in centrality selected Pb+Pb collisions at 40A GeV and 158A GeV beam energy as well as in semicentral C+C and Si+Si interactions at 40A GeV. Transverse mass spectra, rapidity spectra, and total yields are determined as a function of

  5. Beamline for schools beam line training day

    CERN Multimedia

    Photo Service, CERN

    2014-01-01

    The first two teams to participate in CERN's Beamline for Schools project spent their second day at CERN learning the basics of beam physics, and visiting their experimental setup at the T9 beam line in CERN's East Hall on the Meyrin site.

  6. Beam line for Schools: beyond expectations

    CERN Multimedia

    Cian O'Luanaigh

    2014-01-01

    Out of 292 proposals for CERN's first ever "Beam line for Schools" contest, two teams of high-school students – Odysseus' Comrades from Varvakios Pilot School in Athens, Greece and Dominicuscollege from Dominicus College in Nijmegen in the Netherlands – were selected to spend 10 days conducting their proposed experiments at the fully equipped T9 beam line on CERN's Meyrin site. Dedicated CERN staff and users from across the departments have put in a huge effort to ensure the success of the project.   Detector physicist Cenk Yidriz (centre, white helmet) explains the setup of the "Beamline for schools" experiment at the T9 beamline. It's finally beam time. After months of organisation, coding, engineering and even painting the experimental area, the T9 beam line is ready to deliver protons to experiments devised and built by high-school students. “They are here to collect data and experience the l...

  7. Current status of HESYRL lithography beam line

    Science.gov (United States)

    Qian, Shinan; Li, Guihe; Liu, Zewen; Chen, Qianhong; Jiang, Dikui; kan, Ya; Liu, Wanpo

    1990-06-01

    A lithography beam line, as the first of possibly six or more, has been installed in the Hefei Synchrotron Radiation Laboratory (HESYRL). A scanning mirror is used to cut off shorter wavelengths and to expand exposure dimensions vertically. The scanning mirror is oscillated by a stepping motor while an in-situ Moirè fringe grating system measures motor speed uniformity. Some testing results are given. In the first part of the beam line, there is a beryllium window to block longer wavelength light, a laser alignment unit to align the beam line and a special exposure shutter, which is controlled by another stepping motor. An exposure chamber with vacuum of 5 × 10-7 torr is located 7 meters downstream from the source point. Because there is no window at the entrance of the chamber, a differential pumping system is needed. The chamber is equipped with a mask-wafer system, driven by a third stepping motor.

  8. Kaons in nuclear matter

    Energy Technology Data Exchange (ETDEWEB)

    Heiselberg, H. [NORDITA, Copenhagen (Denmark)

    1998-06-01

    The kaon energy in a nuclear medium and its dependence on kaon-nucleon and nucleon-nucleon correlations is discussed. The transition from the Lenz potential at low densities to the Hartree potential at high densities can be calculated analytically by making a Wigner-Seitz cell approximation and employing a square well potential. As the Hartree potential is less attractive than the Lenz one, kaon condensation inside cores of neutron stars appears to be less likely than previously estimated. (orig.)

  9. Bose-Einstein correlations of charged kaons in central Pb + Pb collisions at $E_{beam}$ = 158 GeV per nucleon

    CERN Document Server

    Afanasiev, S V; Baatar, B; Barna, D; Bartke, Jerzy; Barton, R A; Behler, M; Betev, L; Bialkowska, H; Billmeier, A; Blume, C; Blyth, C O; Boimska, B; Botje, M; Bracinik, J; Bramm, R; Brun, R; Buncic, P; Cerny, V; Chvala, O; Cramer, J G; Csató, P; Dinkelaker, P; Eckardt, V; Filip, P; Fodor, Z; Foka, P Y; Freund, P; Friese, V; Gál, J; Gazdzicki, M; Georgopoulos, G; Gladysz-Dziadus, E; Hegyi, S; Höhne, C; Igo, G; Jones, P G; Kadija, K; Karev, A; Kolesnikov, V I; Kollegger, T; Kowalski, M; Kraus, I; Kreps, M; Van Leeuwen, M; Lednicky, R; Lévai, Peter; Malakhov, A I; Margetis, S; Markert, C; Mayes, B W; Melkumov, G L; Meurer, C; Mischke, A; Mitrovski, M; Molnár, J; Nelson, J M; Pálla, G; Panagiotou, A D; Perl, K; Petridis, A; Pikna, M; Pinsky, L; Pühlhofer, F; Reid, J G; Renfordt, R E; Retyk, W; Roland, C; Roland, G; Rybicki, A; Sammer, T; Sandoval, A; Sann, H; Schmitz, N; Seyboth, P; Siklér, F; Sitár, B; Skrzypczak, E; Squier, G T A; Stock, R; Ströbele, H; Susa, T; Szentpétery, I; Sziklai, J; Trainor, T A; Varga, D; Vassiliou, Maria; Veres, G I; Vesztergombi, G; Vranic, D; Wetzler, A; Whitten, C; Yoo, I K; Zaranek, J; Zimányi, J; 10.1016/S0370-2693(03)00102-3

    2003-01-01

    Bose-Einstein correlations of charged kaons were measured near mid- rapidity in central Pb + Pb collisions at 158 A GeV by the NA49 experiment at the CERN SPS. Source radii were extracted using the Yano-Koonin-Podgoretsky and Bertsch-Pratt parameterizations. The results are compared to published pion and kaon data. The measured m /sub perpendicular to / dependence for kaons and pions is consistent with collective transverse expansion of the source and a freeze-out time of about 9.5 fm. (31 refs).

  10. Implementation of EPICS based Control System for Radioisotope Beam line

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    Korea Mult-purpose Accelerator Complex (KOMAC) has been operating 100 MeV proton linear accelerator . For operating 100 MeV linac, various control system has been implemented such as vacuum, power supply, RCCS and etc. KOMAC is operating two beam lines so that clients can use 100 MeV proton beam for their experiment. KOMAC sends beam to beam line and target room using two dipole magnets and several quadrupole magnets. As demand for experiments and Radius Isotope using beam is increased, another beam line is under construction and RI beam line control system is need. To synchronize with KOMAC control system, RI beam line control system is based on Experimental Physics and Industrial control System (EPICS) software. The beam is transported to RI beam line to control magnet power supply and vacuum. Implementation of RI beam line control system is presented and some preliminary results are reported. The base RI beam line control system is implemented. It can control beam direction and vacuum. Comparing archived data and current data, RI beam line and control system will be improved. In the future, scroll pump and gate control system will be implemented using programmable logic controller PLC. RI beam interlock sequence will be added to KOMAC interlock system to protect linac.

  11. High spin isomer beam line at RIKEN

    Energy Technology Data Exchange (ETDEWEB)

    Kishida, T.; Ideguchi, E.; Wu, H.Y. [Institute of Physical and Chemical Research, Saitama (Japan)] [and others

    1996-12-31

    Nuclear high spin states have been the subject of extensive experimental and theoretical studies. For the production of high spin states, fusion reactions are usually used. The orbital angular momentum brought in the reaction is changed into the nuclear spin of the compound nucleus. However, the maximum induced angular momentum is limited in this mechanism by the maximum impact parameter of the fusion reaction and by the competition with fission reactions. It is, therefore, difficult to populate very high spin states, and as a result, large {gamma}-detector arrays have been developed in order to detect subtle signals from such very high spin states. The use of high spin isomers in the fusion reactions can break this limitation because the high spin isomers have their intrinsic angular momentum, which can bring the additional angular momentum without increasing the excitation energy. There are two methods to use the high spin isomers for secondary reactions: the use of the high spin isomers as a target and that as a beam. A high spin isomer target has already been developed and used for several experiments. But this method has an inevitable shortcoming that only {open_quotes}long-lived{close_quotes} isomers can be used for a target: {sup 178}Hf{sup m2} (16{sup +}) with a half-life of 31 years in the present case. By developing a high spin isomer beam, the authors can utilize various short-lived isomers with a short half-life around 1 {mu}s. The high spin isomer beam line of RIKEN Accelerator Facility is a unique apparatus in the world which provides a high spin isomer as a secondary beam. The combination of fusion-evaporation reaction and inverse kinematics are used to produce high spin isomer beams; in particular, the adoption of `inverse kinematics` is essential to use short-lived isomers as a beam.

  12. Radioactive ion beam line in Lanzhou

    Institute of Scientific and Technical Information of China (English)

    詹文龙; 郭忠言; 刘冠华; 党建荣; 何锐荣; 周嗣信; 尹全民; 罗亦孝; 王义芳; 魏宝文; 孙志宇; 肖国青; 王金川; 江山红; 李加兴; 孟祥伟; 张万生; 秦礼军; 王全进

    1999-01-01

    Radioactive ion beam line in Lanzhou (RIBLL) has been constructed for the production of short-lived radioactive nuclei and studies of exotic nuclei far from the β-stability line. It has been put into operation recently at the National Laboratory of Heavy Ion Accelerator Lanzhou. RIBLL consists of two doubly achromatic parts with a solid acceptance ΔΩ≥6.5 msr, momentum acceptance Δp/p=±5% and maximum magnetic rigidity Bρmax=4.2 Tm. The second part of RIBLL serving as a spectrometer gives an element resolution Z/ΔZ>150 and mass resolution A/ΔA>300. The polarized secondary beams can be obtained by using a swinger dipole magnet to change the incident direction of primary projectile from 0°to 5°. The shortest lift time for secondary beams on RIBLL is less than 1μs. First experiments were performed with neutron rich nuclei for understanding the properties of halo nuclei and exotic nuclear reactions.

  13. Synthesis of Beam Lines with Necessary Properties

    CERN Document Server

    Andrianov, Serge

    2005-01-01

    In this paper a new approach to the problem of synthesis of beam lines is discussed. Usually this problem can be overcome by the use of numerical simulation and optimal control theory methods. But this results in sufficiently great number of variable parameters and functions. Obviously, that this degrades quality of a modeling procedure. The suggested approach is demonstrated on a problem of a microprobe design problem. Essence of the problem is that necessary to design a high precision focusing system which satisfies some additional conditions. For solution of this problem we use an algebraic treatment based on Lie algebraic methods and computer algebra techniques. Using the symmetry ideology this approach allows rewriting beam properties to enough simple conditions for control parameters and functions. This leads a set of desired solutions and show results in some most suitable form. Moreover, this approach decreases the number of variable parameters.

  14. Direct CP violation in neutral kaon decays

    Indian Academy of Sciences (India)

    Wojciech Wiślicki

    2004-03-01

    The final result of the NA48 experiment is presented and performed at the CERN SPS neutral kaon beams, on the direct CP violation parameter Re$('/)$, as measured from the decay rates of neutral kaons into two pions. The data collected in the years 1997-2001 yield the evidence for the direct CP violation with Re$('/)=(14.7± 2.2)× 10^{-4}$. Description of experimental method and systematics, comparison with the corresponding FNAL result and discussion of some implications for the theory are given.

  15. Beam Line: 100 years of elementary particles

    Science.gov (United States)

    Pais, A.; Weinberg, S.; Quigg, C.; Riordan, M.; Panofsky, W. K. H.

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  16. Multi-transmission-line-beam interactive system

    Energy Technology Data Exchange (ETDEWEB)

    Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

    2013-11-15

    We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

  17. RARE KAON DECAYS.

    Energy Technology Data Exchange (ETDEWEB)

    LITTENBERG, L.

    2005-07-19

    Lepton flavor violation (LFV) experiments have probed sensitivities corresponding to mass scales of well over 100 TeV, making life difficult for models predicting accessible LFV in kaon decay and discouraging new dedicated experiments of this type.

  18. Analysis of transmission efficiency of SSRF electron beam transfer lines

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this article, the main factors which influence transmission efficiency of the SSRF electron beam transfer lines are described, including physical requirements for magnet system, vacuum system, beam diagnostic system,trajectory correction system, etc. The dynamic simulation calculation and transmission efficiency analysis of the SSRF electron beam transfer lines are presented, and the studies show that the design purpose of efficient beam transmission and injection will be achieved.

  19. Kaon Physics Review

    CERN Document Server

    Lellouch, L

    2009-01-01

    I critically review recent lattice QCD results relevant for kaon phenomenology, as well as the methods that are used to obtain them. The focus is on calculations with N_f=2 and N_f=2+1 flavors of sea quarks. Concerning methodology, the subjects covered include a discussion of how best to extrapolate and/or interpolate results to the physical quark-mass point, a scheme for assessing the extent to which a lattice QCD calculation includes the various effects required to compute a given quantity reliably and a procedure for averaging lattice results. The phenomenological topics that I review comprise leptonic and semileptonic kaon decays, as well as neutral kaon mixing and CP violation in K->\\pi\\pi decays.

  20. Enhancing the accelerated beam current in the booster synchrotron by optimizing the transport line beam propagation

    Indian Academy of Sciences (India)

    Saini R S; Tyagi Y; Ghodke A D; Puntambekar T A

    2016-04-01

    In this paper, we present the results of transverse beam emittance and twiss parameter measurement of an electron beam, delivered by a 20 MeV microtron which is used as a pre-injector system for a booster synchrotron in the Indus Accelerator Facility at RRCAT Indore. Based on these measured beam parameters, beam optics of a transport line was optimized and its results are alsodiscussed in this paper. This beam transport line is used to transport the electron beam from the 20MeV microtron to the booster synchrotron. The booster synchrotron works as a main injector for Indus-1 and Indus-2 synchrotron radiation facilities. To optimize the beam optics of a transport linefor proper beam transmission through the line as well as to match the beam twiss parameters at the beam injection point of another accelerator, it is necessary to know the transverse beam emittance and twiss parameters of the beam coming from the first one. A MATLAB-based GUI program has been developed to calculate the beam emittance and twiss parameters, using quadrupole scanmethod. The measured parameters have been used for beam transport line optimization and twiss parameters matching at booster injection point. After this optimization, an enhancement of ∼50% beam current has been observed in the booster synchrotron.

  1. Muon Beam Studies in the H4 beam line and the Gamma Irradiation Facility (GIF++)

    CERN Document Server

    Margraf, Rachel; CERN. Geneva. EN Department

    2017-01-01

    In this report, I summarize my work of detailed study and optimization of the muon beam configuration of H4 beam line in SPS North Area. Using Monte-Carlo simulations, I studied the properties and behavior of the muon beam in combination with the field of the large, spectrometer “ GOLIATH” magnet at -1.5, -1.0, 0, 1.0 and 1.5 Tesla, which is shown to affect the central x position of the muon beam that is delivered to the Gamma Irradiation Facility (GIF++). I also studied the muon beam for different configurations of the two XTDV beam dumps upstream of GIF++ in the H4 beam line. I will also discuss my role in mapping the magnetic field of the GOLIATH magnet in the H4 beam line.

  2. Beam coupling impedances of fast transmission-line kickers.

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey)

    2002-01-01

    Fast transmission-line kickers contain no ferrite and consist of two long metallic parallel plates supported by insulators inside a beam pipe. A beam is deflected by both the electric and magnetic fields of a TEM wave created by a pulse propagating along the strips in the direction opposite to the beam. Computations of the beam coupling impedances for such structures are difficult because of their length. In the paper, the beam coupling impedances of transmission-line kickers are calculated by combining analytical and numerical methods: the wake potentials computed in short models are extended analytically to obtain the wakes for the long kickers, and then the corresponding beam impedances are derived. At very low frequencies the results are compared with simple analytical expressions for the coupling impedances of striplines in beam position monitors.

  3. Neutrinos from PIon Beam Line, nuPIL

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, J. B. [Imperial Coll., London; Pasternak, J. [Imperial Coll., London; Bross, A. [Fermilab; Liu, A. [Fermilab

    2016-05-05

    LBNF-DUNE (Long Baseline Neutrino Facilities - Deep Underground Neutrino Experiment) is a project based at Fermilab to study neutrino oscillations. The current baseline regarding the neutrino production considers the conventional approach: a high energy proton beam hits a target, producing pions that are collected by a horn and that decay in a decay pipe. An alternative solution, called nuPIL (neutrinos from a Pion beam Line) consists of using a beam line to guide the pions to clean the beam and to put instrumentation to monitor it. This paper presents the concept and the first preliminary results.

  4. International Meeting on Physics at KAON

    CERN Document Server

    Gill, David; Speth, Josef

    1990-01-01

    "Physics at KAON", an international meeting jointly organized by the KFA Jillich and TRI­ UMF, was held in the Physikzentrum Bad Honnef from June 7 through June 9, 1989. This was one of a series of meetings - the first one in Europe - in which plans for the medium energy physics laboratory KAON were presented and some aspects of the physics at this new facility were discussed. The meeting focussed mainly on the topics of hadron spectroscopy, J{ -meson scattering, strangeness in nuclei, and rare decays. Also presented were some of the research programs at SATURNE and COSY which may well lead to KAON physics in the future. These proceed­ ings include articles which summarize our current experimental and theoretical knowledge in the various areas, as well as papers which describe lines of research feasible with KAON. The large number of participants - limited, in fact, by the capacity of the Physikzentrum - clearly demonstrates the great interest of the European physics community in the research avenue...

  5. Radiation Shielding Design for ISOL System Beam Line

    Institute of Scientific and Technical Information of China (English)

    WANG; Feng; QIN; Jiu-chang

    2013-01-01

    The beam line of the ISOL system passes through the shielding wall and connects the HI-13 tandem accelerator.Neutron produced by tandem accelerator will affect the area of BRIF through the beam line.To protect the staff in BRIF area from radiation a shielding design of the beam line is carried out.The neutron source in the vault of tandem accelerator is the H.E Faraday cup of HI-13 tandem accelerator as showed in Fig.1.The Faraday cup is consisted of 1 mm molybdenum sheet and 10 mm

  6. Generate Uniform Transverse Distributed Electron Beam along a Beam Line

    CERN Document Server

    Jiao, Y

    2015-01-01

    It has been reported that transverse distribution shaping can help to further enhance the energy extraction efficiency in a terawatt, tapered X-ray free-electron laser. Thus, methods of creating and keeping almost uniform transverse distributed (UTD) beam within undulators are required. This study shows that a UTD electron beam can be generated within evenly distributed drift sections where undulators can be placed, by means of octupoles and particular optics. A concrete design is presented, and numerical simulations are done to verify the proposed method.

  7. Kaon Physics at KLOE

    CERN Document Server

    Ambrosino, F; Antonelli, M; Bacci, C; Beltrame, P; Bencivenni, G; Bertolucci, Sergio; Bini, C; Bloise, C; Bocci, V; Bossi, F; Bowring, D; Branchini, P; Caloi, R; Campana, P; Capon, G; Capussela, T; Cera, F; Chi, S; Chiefari, G; Ciambrone, P; Conetti, S; De Lucia, E; De Santis, A; De Simone, P; De Zorzi, G; Dell'Agnello, S; Denig, A; Di Domenico, A; Di Donato, C; Di Falco, S; Di Micco, B; Doria, A; Dreucci, M; Fe, G; Ferrari, A; Ferrer, M L; Finocchiaro, G; Fiore, S; Forti, C; Franzini, P; Gatti, C; Gauzzi, P; Giovannella, S; Gorini, E; Graziani, E; Incagli, M; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Leone, D; Martini, M; Massarotti, P; Mei, W; Meola, S; Miscetti, S; Moulson, M; Müller, S; Murtas, F; Napolitano, M; Nguyen, F; Palutan, M; Pasqualucci, E; Passeri, A; Patera, V; Perfetto, F; Pontecorvo, L; Primavera, M; San, P; Santovetti, E; Saracino, G; Sciascia, B; Sciubba, A; Scuri, F; Sfiligoi, I; Spadaro, T; Testa, M; Tortora, L; Valente, P; Valeriani, B; Venanzoni, G; Veneziano, Stefano; Ventura, A; Versaci, R; Xu, G; Palutan, Matteo

    2006-01-01

    The most precise determination of Vus comes from semileptonic kaon decays. We have measured with the KLOE detector at DAFNE, the Frascati phi-factory, all the experimental inputs to Vus for both neutral and charged kaons. Using our results we extract the value of Vus with about 0.9% fractional error, which is entirely dominated by the theoretical error on the knowledge of the normalization of the decay form factors, f0. A new determination of the ratio Vus/Vud is also presented, based on our precise measurement of the absolute branching ratio for the decay K+ -> mu+nu, combined with recent lattice results for the ratio f_K/f_pi. New results on CPT symmetry have also been achieved, which are based on the first measurement of the charge asymmetry for Ks -> pi e nu decay.

  8. Alignment Sensitivity Study of the St. ANA Beam Line

    Science.gov (United States)

    Gervais, Michelle; Couder, Manoel; Jung, Hyo Soon; Setoodehnia, Kiana

    2014-09-01

    The St. ANA (STable Accelerator for Nuclear Astrophysics) accelerator is being prepared for use with the St. George recoil mass separator. The accelerator is in working condition for use in direct kinematic experiments but the St. George separator works with inverse kinematics and requires a highly controlled beam restricted by severe position and divergence parameters that are not achieved at the present time. A systematic sensitivity study was conducted using a simulation of the beam line in order to assess the impact of a misalignment in each optical element or in the beam itself. Tests were done with the beam to analyze how the beam behaves at various points in the line and to compare this data with simulation results to determine possible causes of misalignment. The results of these tests and simulations are that the beam characteristics are now better understood and the possible causes of the limitations have been narrowed down. The St. ANA (STable Accelerator for Nuclear Astrophysics) accelerator is being prepared for use with the St. George recoil mass separator. The accelerator is in working condition for use in direct kinematic experiments but the St. George separator works with inverse kinematics and requires a highly controlled beam restricted by severe position and divergence parameters that are not achieved at the present time. A systematic sensitivity study was conducted using a simulation of the beam line in order to assess the impact of a misalignment in each optical element or in the beam itself. Tests were done with the beam to analyze how the beam behaves at various points in the line and to compare this data with simulation results to determine possible causes of misalignment. The results of these tests and simulations are that the beam characteristics are now better understood and the possible causes of the limitations have been narrowed down. Project advisor

  9. The SPS beam lines to the West Hall

    CERN Multimedia

    1976-01-01

    The proton beam arriving from bottom is cut into three parts by the special steel septum magnets, seen in the centre, and then focussed onto the targets just out the sight on the top. The beam line near the right hand wall carries an RF-separated beam to BEBC from a target located deep in the TT60 tunnel. (Annual Report 1976 p. 116)

  10. Improvements and developments on radioactive ion beam line in Lanzhou

    CERN Document Server

    Guo Zhong Yan; Xiao Guo Qing; Xu Hu Shan; Sun Zhi Yu; Li Jia Xing; Wang Meng; Chen Zhi Qiang; Mao Rui Shi; Wang Wu Sheng; Bai Jie; Hu Zheng Guo; Chen Li Xin; Li Chen

    2003-01-01

    The improvements and the developments on radioactive ion beam line in Lanzhou (RIBLL) were carried out. So the performances of RIBLL are toned up evidently. It makes operating and setting RIBLL convenient and reliable

  11. Kaon Production and Interaction

    CERN Document Server

    Wolke, B M; Budzanowski, A; Czyzykiewicz, R; Grzonka, D; Jarczyk, L; Kamys, B; Khoukaz, A; Kilian, K; Kowina, P; Lister, T A; Moskal, P; Oelert, Walter; Rozek, T; Santo, R; Schepers, G; Sefzick, T; Siemaszko, M; Smyrski, J; Steltenkamp, S; Strzalkowski, A; Winter, P; Wüstner, P; Zipper, W; Wolke, By M.

    2003-01-01

    Exclusive data on both the elementary kaon and antikaon production channels have been taken at the cooler synchrotron COSY in proton-proton scattering. In the kaon--hyperon production an enhancement by one order of magnitude of the Lambda/Sigma0 ratio has been observed at excess energies below Q=13 MeV compared to data at higher excess energies (Q>300 MeV). New results obtained at the COSY-11 facility explore the transition region between the regime of this low-energy Sigma0 suppression and excess energies of 60 MeV. A comparison of the energy dependence of the Lambda and Sigma0 total cross sections exhibits distinct qualitative differences between both hyperon production channels. Studies of kaon-antikaon production have been motivated especially by the ongoing discussion about the nature of the scalar resonances f0(980) and a0(980) coupling to the K anti-K channel. For the reaction pp->ppK+K- a first total cross section value is reported at an excess energy of Q=17 MeV, i.e. below the phi threshold. Calcula...

  12. Design and Performance of the CNGS Secondary Beam Line

    CERN Document Server

    Gschwendtner, E; Elsener, K; Ferrari, A; Guglielmi, A; Meddahi, M; Pardons, A; Rangod, Stephane; Sala, P

    2007-01-01

    An intense muon-neutrino beam (1017nm /day) is generated at CERN and directed towards the Gran Sasso National Laboratory, LNGS, in Italy, 732 km away from CERN. In the presently approved physics programme, it is foreseen to run the CNGS facility with 4.5.1019 protons per year for five years. During a nominal CNGS cycle, i.e. every 6s, two nominal SPS extractions of 2.4.1013 protons each at 400GeV/c are sent down the proton beam line to the target. The CNGS secondary beam line, starting with the target, has to cope with this situation, which pushes the beam line equipment and instrumentation to the limits of radiation hardness and mechanical stresses during the CNGS operation. An overview of the CNGS secondary beam line is given. Emphasis is on the target, the magnetic focusing lenses (horn and reflector) and the muon monitors. The performance of the secondary beam line during beam commissioning and physics operation is discussed and measurements are compared with simulations.

  13. Snake beam: a paraxial arbitrary focal line

    OpenAIRE

    Rosen, Joseph; Yariv, Amnon

    1995-01-01

    The creation of paraxial arbitrary focal lines by a Fourier computer-generated hologram is demonstrated. The desired focal line is represented by a series of connected straight line segments, each of which is implemented by a radial harmonic function located on a different radial portion of the entire hologram. Each subhologram is multiplied by appropriate linear and quadratic phase functions and is shifted by some distance from the center. The two phase factors determine the location of each...

  14. System-size and centrality dependence of charged kaon and pion production in nucleus-nucleus collisions at 40A GeV and158A GeV beam energy

    CERN Document Server

    Anticic, T.; Barna, D.; Bartke, J.; Beck, H.; Betev, L.; Bialkowska, H.; Blume, C.; Bogusz, M.; Boimska, B.; Book, J.; Botje, M.; Buncic, P.; Cetner, T.; Christakoglou, P.; Chung, P.; Chvala, O.; Cramer, J.G.; Dinkelaker, P.; Eckardt, V.; Fodor, Z.; Foka, P.; Friese, V.; Gazdzicki, M.; Grebieszkow, K.; Hohne, C.; Kadija, K.; Karev, A.; Kliemant, M.; Kolesnikov, V.I.; Kollegger, T.; Kowalski, M.; Kresan, D.; Laszlo, A.; Lacey, R.; van Leeuwen, M.; Lungwitz, B.; Mackowiak, M.; Makariev, M.; Malakhov, A.I.; Mateev, M.; Melkumov, G.L.; Mitrovski, M.; Mrowczynski, St.; Nicolic, V.; Palla, G.; Panagiotou, A.D.; Peryt, W.; Pluta, J.; Prindle, D.; Puhlhofer, F.; Renfordt, R.; Roland, C.; Roland, G.; Rybczynski, M.; Rybicki, A.; Sandoval, A.; Schmitz, N.; Schuster, T.; Seyboth, P.; Sikler, F.; Skrzypczak, E.; Slodkowski, M.; Stefanek, G.; Stock, R.; Strobele, H.; Susa, T.; Szuba, M.; Utvic, M.; Varga, D.; Vassiliou, M.; Veres, G.I.; Vesztergombi, G.; Vranic, D.; Wlodarczyk, Z.; Wojtaszek-Szwarc, A.

    2012-01-01

    Measurements of charged pion and kaon production are presented in centrality selected Pb+Pb collisions at 40A GeV and 158A GeV beam energy as well as in semi-central C+C and Si+Si interactions at 40A GeV. Transverse mass spectra, rapidity spectra and total yields are determined as a function of centrality. The system-size and centrality dependence of relative strangeness production in nucleus-nucleus collisions at 40A GeV and 158A GeV beam energy are derived from the data presented here and published data for C+C and Si+Si collisions at 158A GeV beam energy. At both energies a steep increase with centrality is observed for small systems followed by a weak rise or even saturation for higher centralities. This behavior is compared to calculations using transport models (UrQMD and HSD), a percolation model and the core-corona approach.

  15. Charged kaon mass measurement using the Cherenkov effect

    Energy Technology Data Exchange (ETDEWEB)

    Graf, N., E-mail: ngraf@umail.iu.ed [Indiana University, Bloomington, IN 47403 (United States); Lebedev, A. [Harvard University, Cambridge, MA 02138 (United States); Abrams, R.J. [University of Michigan, Ann Arbor, MI 48109 (United States); Akgun, U.; Aydin, G. [University of Iowa, Iowa City, IA 52242 (United States); Baker, W. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Barnes, P.D. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Bergfeld, T. [University of South Carolina, Columbia, SC 29201 (United States); Beverly, L. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Bujak, A. [Purdue University, West Lafayette, IN 47907 (United States); Carey, D. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Dukes, C. [University of Virginia, Charlottesville, VA 22904 (United States); Duru, F. [University of Iowa, Iowa City, IA 52242 (United States); Feldman, G.J. [Harvard University, Cambridge, MA 02138 (United States); Godley, A. [University of South Carolina, Columbia, SC 29201 (United States); Guelmez, E.; Guenaydin, Y.O. [University of Iowa, Iowa City, IA 52242 (United States); Gustafson, H.R. [University of Michigan, Ann Arbor, MI 48109 (United States); Gutay, L. [Purdue University, West Lafayette, IN 47907 (United States); Hartouni, E. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2010-03-21

    The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 to +63GeV/c. The measured value is 491.3+-1.7MeV/c{sup 2}, which is within 1.4sigma of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.

  16. Charged Kaon Mass Measurement using the Cherenkov Effect

    CERN Document Server

    Graf, N; Abrams, R J; Akgun, U; Aydin, G; Baker, W; Barnes, P D; Bergfeld, T; Beverly, L; Bujak, A; Carey, D; Dukes, C; Duru, F; Feldman, G J; Godley, A; Gülmez, E; Günaydın, Y O; Gustafson, H R; Gutay, L; Hartouni, E; Hanlet, P; Hansen, S; Heffner, M; Johnstone, C; Kaplan, D; Kamaev, O; Kilmer, J; Klay, J; Kostin, M; Lange, D; Ling, J; Longo, M J; Lu, L C; Materniak, C; Messier, M D; Meyer, H; Miller, D E; Mishra, S R; Nelson, K; Nigmanov, T; Norman, A; Onel, Y; Paley, J M; Park, H K; Penzo, A; Peterson, R J; Raja, R; Rajaram, D; Ratnikov, D; Rosenfeld, C; Rubin, H; Seun, S; Solomey, N; Soltz, R; Swallow, E; Schmitt, R; Subbarao, P; Torun, Y; Tope, T E; Wilson, K; Wright, D; Wu, K

    2009-01-01

    The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 GeV/c to +63 GeV/c. The measured value is 491.3 +/- 1.7 MeV/c^2, which is within 1.4 sigma of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.

  17. R&D of the Fluoroscopes of 100 MeV Cyclotron Beam Lines

    Institute of Scientific and Technical Information of China (English)

    YIN; Meng; GUAN; Feng-ping; XIE; Huai-dong; ZHENG; Xia; XING; Jian-sheng; LV; Yin-long

    2013-01-01

    Beijing Radioactive Ion-beam Facility(BRIF)consists of a 100 MeV H-cyclotron CYCIAE-100and nine beam lines.All the beam lines provide the channels of the proton beam or the neutron beam to the terminal of physics experiment.There are many beam diagnosis monitors distributing along the beam lines,including,Faraday cups,beam position monitors,fluoroscopes,collimators,emittance measurement

  18. An electromagnetically focused electron beam line source

    Science.gov (United States)

    Iqbal, Munawar; Masood, Khalid; Rafiq, Mohammad; Chaudhary, Maqbool A.; Aleem, Fazal-e.-

    2003-11-01

    A directly heated thermionic electron beam source was constructed. A tungsten wire of length 140 mm with diameter 0.9 mm was used as a cathode. An emission current of 5000 mA was achieved at an input heating power of 600 W. Cathode to anode distance of 6 mm with acceleration voltage of 10 kV was used. A uniform external magnetic field of 50 G was employed to obtain a well-focused electron beam at a deflection of 180°, with cathode to work site distance of 130 mm. Dimensions of the beam (1.25×120 mm) recorded at the work site were found to be in good agreement with the designed length of cathode. The deformation of the cathode was overcome by introducing a spring action mechanism, which gives uniform emission current density throughout the emission surface. We have achieved the saturation limit of the designed source resulting in smooth and swift operation of the gun for many hours (10-15 h continuously). The design of gun is so simple that it can accommodate longer cathodes for obtaining higher emission values. This gun has made it possible to coat large substrate surfaces at much faster evaporation rate at lower cost. It can also be useful in large-scale vacuum metallurgy plants for melting, welding and heat treatment.

  19. Materials research and beam line operation utilizing NSLS. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Liedl, G.L.

    1993-06-01

    MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year all 232 operational days were fully utilized. Beam line tests coupled with MATRIX members combined to use 284 days. General user demand for use of the beam line continues to be strong and four groups were provided 48 operating days. Research production has been growing as NSLS and the beam line become a more stable type of operation. For 1992 the MATRIX group published six articles. To date, for 1993 the same group has published, submitted, or has in preparation nine articles. Recent research milestones include: the first quantitative structural information on the as-quenched and early stages of decomposition of supersaturated Al-Li alloys; the first quantitative diffuse scattering measurements on a complex system (Co substitute for Cu YBCO superconductor); demonstration of capabilities of a new UHV surface diffraction chamber with in-situ characterization and temperature control (30-1300K); feasibility of phasing structure factors in a quasicrystal using multiple Bragg scattering.

  20. Beam Diagnostics Instrumentation for the High Energy Beam Transport Line of I.P.H.I.

    CERN Document Server

    Ausset, P; Coacolo, J L; Lesrel, J; Maymon, J N; Olivier, A; Rouviere, N; Solal-Cohen, M; Vatrinet, L; Yaniche, J F

    2005-01-01

    I.P.H.I. is a High Intensity Proton Injector under construction at Saclay (C.N.R.S/ I.N.2P.3; C.E.A. / D.A.P.N.I.A and C.E.R.N. collaboration). An E.C.R. produces a 100 keV, 100 mA C.W. proton beam which will be accelerated at 3 MeV by a 4 vanes R.F.Q. operating at 352.2 MHz. Finally, a High Energy Beam Transport Line (H.E.B.T.) will deliver the beam to a beam stopper and will be equipped with appropriate beam diagnostics to carry intensity; centroïd beam transverse position, transverse beam profiles, beam energy and energy spread measurements for the commissioning of I.P.H.I. These beam diagnostics will operate under both pulsed and C.W. operation. Transverse beam profile measurements will be acquired under low and high duty factor pulsed beam operation using a slow wire scanner and a C.C.D. camera to image the beam-induced fluorescence. The beam instrumentation of the H.E.B.T. is reviewed and preliminary obtained transverse profile measurements at 100 keV are described.

  1. Beam diagnostics instrumentation for the high energy beam transfer line of I.P.H.I

    Energy Technology Data Exchange (ETDEWEB)

    Ausset, P.; Berthelot, S.; Coacolo, J.L.; Lesrel, J.; Maymon, J.N.; Olivier, A.; Rouviere, N.; Solal, M.; Vatrinet, L.; Yaniche, J.F. [Institut de Physique Nucleaire, (IN2P3/CNRS) 91 - Orsay (France); Belyaev, G.; Roudskoy, I. [I.T.E.P. Moscow (Russian Federation)

    2005-07-01

    I.P.H.I. is a High Intensity Proton Injector under construction at Saclay. An E.C.R. source produces a 100 keV, 100 mA C.W. proton beam which will be accelerated at 3 MeV by a 4 vanes R.F.Q. operating at 352.2 MHz. Finally, a High Energy Beam Transport Line (H.E.B.T.) will deliver the beam to a beam stopper and will be equipped with appropriate beam diagnostics to carry intensity, centroid beam transverse position, transverse beam profiles, beam energy and energy spread measurements for the commissioning of I.P.H.I. These beam diagnostics will operate under both pulsed and C.W. operation. Transverse beam profile measurements will be acquired under low and high duty factor pulsed beam operation using a slow wire scanner and a C.C.D. camera to image the beam-induced fluorescence. The beam instrumentation of the H.E.B.T. is reviewed and preliminary obtained transverse profile measurements at 100 keV are described. (authors)

  2. A beam optics study of the biomedical beam line at a proton therapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Chong Cheoul [National Center for Inter-University Research Facilities, Seoul National University, Sillim-dong, Gwanak, Seoul (Korea, Republic of); Kim, Jong-Won [Research Institute and Hospital, National Cancer Center, 809 Madu-dong, Ilsan-gu, Koyang, Kyonggi 410 769 (Korea, Republic of)], E-mail: jwkim@ncc.re.kr

    2007-10-15

    A biomedical beam line has been designed for the experimental area of a proton therapy facility to deliver mm to sub-mm size beams in the energy range of 20-50 MeV using the TRANSPORT/TURTLE beam optics codes and a newly-written program. The proton therapy facility is equipped with a 230 MeV fixed-energy cyclotron and an energy selection system based on a degrader and slits, so that beam currents available for therapy decrease at lower energies in the therapeutic beam energy range of 70-230 MeV. The new beam line system is composed of an energy-degrader, two slits, and three quadrupole magnets. The minimum beam sizes achievable at the focal point are estimated for the two energies of 50 and 20 MeV. The focused FWHM beam size is approximately 0.3 mm with an expected beam current of 20 pA when the beam energy is reduced to 50 MeV from 100 MeV, and roughly 0.8 mm with a current of 10 pA for a 20 MeV beam.

  3. Kaon fluctuations from lattice QCD

    CERN Document Server

    Noronha-Hostler, Jacquelyn; Gunther, Jana; Parotto, Paolo; Pasztor, Attila; Vazquez, Israel Portillo; Ratti, Claudia

    2016-01-01

    We show that it is possible to isolate a set of kaon fluctuations in lattice QCD. By means of the Hadron Resonance Gas (HRG) model, we calculate the actual kaon second-to-first fluctuation ratio, which receives contribution from primordial kaons and resonance decays, and show that it is very close to the one obtained for primordial kaons in the Boltzmann approximation. The latter only involves the strangeness and electric charge chemical potentials, which are functions of $T$ and $\\mu_B$ due to the experimental constraint on strangeness and electric charge, and can therefore be calculated on the lattice. This provides an unambiguous method to extract the kaon freeze-out temperature, by comparing the lattice results to the experimental values for the corresponding fluctuations.

  4. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  5. Simulating the Beam-line at CERN's ISOLDE Experiment

    CERN Document Server

    McGrath, Casey

    2013-01-01

    Maximizing the optical matching along portions of the ISOLDE beam-line and automating this procedure will make it easier for scientists to determine what the strengths of the electrical elds of each beam-line element should be in order to reduce particle loss. Simulations are run using a program called MAD-X, however, certain issues were discovered that hindered an immediate success of the simulations. Specifically, the transfer matrices for electrostatic components like the switchyards, kickers, and electric quadrupoles were missing from the original coding. The primary aim of this project was to design these components using AutoCAD and then extract the transfer matrices using SIMION. Future work will then implement these transfer matrices into the MAD-X code to make the simulations of the beam-line more accurate.

  6. On-line laser spectroscopy with thermal atomic beams

    CERN Document Server

    Thibault, C; De Saint-Simon, M; Duong, H T; Guimbal, P; Huber, G; Jacquinot, P; Juncar, P; Klapisch, Robert; Liberman, S; Pesnelle, A; Pillet, P; Pinard, J; Serre, J M; Touchard, F; Vialle, J L

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a CW tunable dye laser interacts at right angles with a thermal atomic beam. /sup 76-98/Rb, /sup 118-145 /Cs and /sup 208-213/Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while /sup 30-31/Na and /sup 38-47/K have been studied by setting the apparatus directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. The hyperfine structure, spins and isotope shifts of the alkali isotopes and isomers are measured. (8 refs).

  7. Beam lines from Linac 1 to PS and Booster

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    View against the direction of the proton beams. The 50 MeV Linac 1 is behind the concrete wall. Its beam emerges from the hole near the centre of the picture. A switching magnet directs the beam either to the PS (to the right in the sense of the beam; original injection line), or lets it go straight on to the Booster (originally 800 MeV, now 1.4 GeV). The huge drum in the line to the Booster is a "debuncher", driven by the 200 MHz RF of the linac. It reduces the beam's momentum spread. This was the last year of Linac 1 as provider of protons to the Booster. Linac 2, nearly completed at the time of this picture, took up trial delivery at the end of 1978, and routine delivery in 1979. The beam line from Linac 2, barely visible here, can be clearly seen on 7802260. Linac 1 had a second life as an ion accelerator.

  8. FIRST BEAM TESTS OF THE MUON COLLIDER TARGET TEST BEAM LINE AT THE AGS.

    Energy Technology Data Exchange (ETDEWEB)

    BROWN,K.A.; GASSNER,D.; GLENN,J.W.; PRIGL,R.; SIMOS,N.; SCADUTO,J.; TSOUPAS,N.

    2001-06-18

    In this report we will describe the muon collider target test beam line which operates off one branch of the AGS switchyard. The muon collider target test facility is designed to allow a prototype muon collider target system to be developed and studied. The beam requirements for the facility are ambitious but feasible. The system is designed to accept bunched beams of intensities up to 1.6 x 10{sup 13} 24 GeV protons in a single bunch. The target specifications require beam spot sizes on the order of 1 mm, 1 sigma rms at the maximum intensity. We will describe the optics design, the instrumentation, and the shielding design. Results from the commissioning of the beam line will be shown.

  9. Confining continuous manipulations of accelerator beam-line optics

    Science.gov (United States)

    Amstutz, Ph.; Plath, T.; Ackermann, S.; Bödewadt, J.; Lechner, C.; Vogt, M.

    2017-04-01

    Altering the optics in one section of a linear accelerator beam line will in general cause an alteration of the optics in all downstream sections. In circular accelerators, changing the optical properties of any beam-line element will have an impact on the optical functions throughout the whole machine. In many cases, however, it is desirable to change the optics in a certain beam-line section without disturbing any other parts of the machine. Such a local optics manipulation can be achieved by adjusting a number of additional corrector magnets that restore the initial optics after the manipulated section. In that case, the effect of the manipulation is confined in the region between the manipulated and the correcting beam-line elements. Introducing a manipulation continuously, while the machine is operating, therefore requires continuous correction functions to be applied to the correcting quadrupole magnets. In this paper, we present an approach to calculate such continuous correction functions for six quadrupole magnets by means of a homotopy method. Besides a detailed derivation of the method, we present its application to an algebraic example, as well as its demonstration at the seeding experiment sFLASH at the free-electron laser FLASH located at DESY in Hamburg.

  10. Overview of kaon decay physics

    CERN Document Server

    Peccei, Roberto D

    1995-01-01

    After a brief history of the insights gained from Kaon physics, the potential of Kaon decays for probing lepton number violation is discussed. Present tests of CTP and of Quantum Mechanics in the neutral Kaon sector are then reviewed and the potential of the Frascati \\Phi factory for doing incisive tests in this area is emphasized. The rest of this overview focuses on CP violating effects in the Kaon system. Although present observations of CP violation are perfectly consistent with the CKM model, we emphasize the theoretical and experimental difficulties which must be faced to establish this conclusively. In so doing, theoretical predictions and experimental prospects for detecting \\Delta S=1 CP violation through measurements of \\epsilon^\\prime/\\epsilon and of rare K decays are reviewed. The importance of looking for evidence for non-CKM CP-violating phases, through a search for a non-vanishing transverse muon polarization in K_{\\mu 3} decays, is also stressed.

  11. Preliminary design of electrostatic sensors for MITICA beam line components

    Energy Technology Data Exchange (ETDEWEB)

    Spagnolo, S., E-mail: spagnolo@igi.cnr.it; Spolaore, M.; Dalla Palma, M.; Pasqualotto, R.; Sartori, E.; Serianni, G.; Veltri, P. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, 35127 Padova (Italy)

    2016-02-15

    Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

  12. Error analysis in post linac to driver linac transport beam line of RAON

    Science.gov (United States)

    Kim, Chanmi; Kim, Eun-San

    2016-07-01

    We investigated the effects of magnet errors in the beam transport line connecting the post linac to the driver linac (P2DT) in the Rare Isotope Accelerator in Korea (RAON). The P2DT beam line is bent by 180-degree to send the radioactive Isotope Separation On-line (ISOL) beams accelerated in Linac-3 to Linac-2. This beam line transports beams with multi-charge state 132Sn45,46,47. The P2DT beam line includes 42 quadrupole, 4 dipole and 10 sextupole magnets. We evaluate the effects of errors on the trajectory of the beam by using the TRACK code, which includes the translational and the rotational errors of the quadrupole, dipole and sextupole magnets in the beam line. The purpose of this error analysis is to reduce the rate of beam loss in the P2DT beam line. The distorted beam trajectories can be corrected by using six correctors and seven monitors.

  13. International Conference on Kaon Physics

    CERN Document Server

    2016-01-01

    The Conference follows former editions with similar emphasis on kaon physics. aiming at a comprehensive discussion on the latest experimental and theoretical achievements and development of new projects. TOPICS: CP and T violation CKM matrix and Flavor Mixing Rare decays Precise SM tests CPT and Quantum Mechanics Lepton universality and flavor violation Lattice gauge theory Chiral perturbation theory Physics beyond the Standard Model Future opportunities in Kaon Physics

  14. Monte Carlo Simulations of Beam Losses in the Test Beam Line of CTF3

    CERN Document Server

    Nebot Del Busto, E; Branger, E; Holzer, E B; Doebert, S; Lillestol, R L; Welsch, C P

    2013-01-01

    The Test Beam Line (TBL) of the CLIC Test Facility 3 (CTF3) aims to validate the drive beam deceleration concept of CLIC, in which the RF power requested to boost particles to multi-TeV energies is obtained via deceleration of a high current and low energy drive beam (DB). Despite a TBL beam energy (150-80 MeV) significantly lower than the minimum nominal energy of the CLIC DB (250 MeV), the pulse time structure of the TBL provides the opportunity to measure beam losses with CLIC-like DB timing conditions. In this contribution, a simulation study on the detection of beam losses along the TBL for the commissioning of the recently installed beam loss monitoring system is presented. The most likely loss locations during stable beam conditions are studied by considering the beam envelope defined by the FODO lattice as well as the emittance growth due to the deceleration process. Moreover, the optimization of potential detector locations is discussed. Several factors are considered, namely: the distance to the bea...

  15. G4beamline Particle Tracking in Matter Dominated Beam Lines

    Energy Technology Data Exchange (ETDEWEB)

    T.J. Roberts, K.B. Beard, S. Ahmed, D. Huang, D.M. Kaplan

    2011-03-01

    The G4beamline program is a useful and steadily improving tool to quickly and easily model beam lines and experimental equipment without user programming. It has both graphical and command-line user interfaces. Unlike most accelerator physics codes, it easily handles a wide range of materials and fields, being particularly well suited for the study of muon and neutrino facilities. As it is based on the Geant4 toolkit, G4beamline includes most of what is known about the interactions of particles with matter. We are continuing the development of G4beamline to facilitate its use by a larger set of beam line and accelerator developers. A major new feature is the calculation of space-charge effects. G4beamline is open source and freely available at http://g4beamline.muonsinc.com

  16. Laser-driven beam lines for delivering intensity modulated radiation therapy with particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, K. M.; Schell, S.; Wilkens, J. J. [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 München (Germany)

    2013-07-26

    Laser-accelerated particles can provide a promising opportunity for radiation therapy of cancer. Potential advantages arise from combining a compact, cost-efficient treatment unit with the physical advantages in dose delivery of charged particle beams. We consider different dose delivery schemes and the required devices to design a possible treatment unit. The secondary radiation produced in several beam line elements remains a challenge to be addressed.

  17. Neutronics Assessments for a RIA Fragmentation Line Beam Dump Concept

    CERN Document Server

    Boles, Jason; Reyes, Susana; Stein, Werner

    2005-01-01

    Heavy ion and radiation transport calculations are in progress for conceptual beam dump designs for the fragmentation line of the proposed Rare Isotope Accelerator (RIA). Using the computer code PHITS, a preliminary design of a motor-driven rotating wheel beam dump and adjacent downstream multipole has been modeled. Selected results of these calculations are given, including neutron and proton flux in the wheel, absorbed dose and displacements per atom in the hub materials, and heating from prompt radiation and from decay heat in the multipole.

  18. Beam manipulation and acceleration with Dielectric-Lined Waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Lemery, Francois [Northern Illinois Univ., DeKalb, IL (United States)

    2015-06-01

    The development of next-generation TeV+ electron accelerators will require either immense footprints based on conventional acceleraton techniques or the development of new higher{gradient acceleration methods. One possible alternative is beam-driven acceleration in a high-impedance medium such as a dielectric-lined-waveguide (DLW), where a highcharge bunch passes through a DLW and can excite gradients on the order of GV/m. An important characteristic of this acceleration class is the transformer ratio which characterizes the energy transfer of the scheme. This dissertation discusses alternative methods to improve the transformer ratio for beam-driven acceleration and also considers the use of DLWs for beam manipulation at low energy.

  19. Physics at the new CERN neutron beam line

    CERN Document Server

    Guerrero, C

    2014-01-01

    A new neutron beam line (n_TOF EAR - 2) is being built at CERN within the n_TOF facility. Compared to the existing 185 meters long time - of - flight beam line, the new one (which will operate in parallel) will feature a shorter flight of 20 meters, providing a 2 7 times more intense neutron flux extending from thermal to 300 MeV. The scientific program is now bein g discussed and the first detailed proposals will be refereed by February 2014. This contribution is devoted to present and discuss the expected performance of the facility, briefly, and the details of some of the first measureme nts foreseen for 2014 and 2015.

  20. Kaon photoproduction off proton

    Science.gov (United States)

    Skoupil, Dalibor; Bydžovský, Petr

    2016-11-01

    We have recently constructed our version of the Regge-plus-resonance (RPR) model and two variants of an isobar model for photoproduction of kaons on the proton, utilizing new experimental data from CLAS, LEPS, and GRAAL collaborations for adjusting free parameters of the models. Higher-spin nucleon (3/2 and 5/2) and hyperon (3/2) resonances were included using the consistent formalism by Pascalutsa and found to play an important role in data description. The set of chosen nucleon resonances in our new isobar models agrees well with the set of the most probable contributing states determined in the Bayesian analysis with the RPR model whilst only 6 out of 10 N*'s selected in the RPR fit of ours overlap with the nucleon resonant states in the Bayesian analysis. Results of two versions of the isobar model are compared to the new version of the RPR model and experimental data in the third-resonance region and their properties are discussed. We place an emphasis on the choice of resonances, the predictions in the forward- and backward-angle region as well as the choice of the hadron form factor.

  1. Kaon photoproduction off proton

    Directory of Open Access Journals (Sweden)

    Skoupil Dalibor

    2016-01-01

    Full Text Available We have recently constructed our version of the Regge-plus-resonance (RPR model and two variants of an isobar model for photoproduction of kaons on the proton, utilizing new experimental data from CLAS, LEPS, and GRAAL collaborations for adjusting free parameters of the models. Higher-spin nucleon (3/2 and 5/2 and hyperon (3/2 resonances were included using the consistent formalism by Pascalutsa and found to play an important role in data description. The set of chosen nucleon resonances in our new isobar models agrees well with the set of the most probable contributing states determined in the Bayesian analysis with the RPR model whilst only 6 out of 10 N*’s selected in the RPR fit of ours overlap with the nucleon resonant states in the Bayesian analysis. Results of two versions of the isobar model are compared to the new version of the RPR model and experimental data in the third-resonance region and their properties are discussed. We place an emphasis on the choice of resonances, the predictions in the forward- and backward-angle region as well as the choice of the hadron form factor.

  2. 3B1 beam line and its physical properties

    Science.gov (United States)

    Yi, Futing; Wang, Peiwei; Jin, Ming; Wu, Jianwu

    1995-02-01

    The 3B1 beam line is in the hall of 13# on BSRF, and is used for the lithography, biology and multilayer reflection research. On the line, there are a cylinder mirror system, a vacuum control system, an exposure chamber and a beryllium window for lithography research. The mirror coated with gold receives the synchrotron radiation at a glance angle of 1.5°, and scans in the vertical for lithography. The light, reflected by the scanning mirror and absorbed by the window, produces a spectrum of 4-20 Å and a uniformity spot for the lithography.

  3. Beam Line and Associated Work: Operational Phase 1985-1987

    Science.gov (United States)

    1988-08-26

    237 582-32 Optics for ineertion-devcs beam lines, V. Rehn. Michelson Lab. (invited Paper).............................. 238 582-35 The SSRL...University; Claudia Pellegrini, Brookhaven National Laboratory; Victor Rehn, Michelson Laboratory/U.S. Naval Weapons Center; R. P. Walker, SERC...moving through a bolted-together pair of Cu monoliths . Due to symmetry, the turning pro- cers yielded two mirrors, one of which is shown in Fig. 2. As is

  4. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    Science.gov (United States)

    Scisciò, M.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Papaphilippou, Y.; Antici, P.

    2016-03-01

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  5. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    Energy Technology Data Exchange (ETDEWEB)

    Scisciò, M.; Antici, P., E-mail: patrizio.antici@polytechnique.edu [INFN-RM1 and SBAI, Università di Roma “La Sapienza,” Via Scarpa 16, 00161 Roma (Italy); INRS-EMT, Université du Québec, 1650 Lionel Boulet, Varennes, Québec J3X 1S2 (Canada); Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L. [INFN-RM1 and SBAI, Università di Roma “La Sapienza,” Via Scarpa 16, 00161 Roma (Italy); Papaphilippou, Y. [CERN, CH 1211 Geneva 23 (Switzerland)

    2016-03-07

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  6. Bending magnets for the CBA beam-transport line

    Energy Technology Data Exchange (ETDEWEB)

    Thern, R.E.

    1983-01-01

    The beam-transport line from the AGS to CBA requires 68 large bending magnets, consisting of pure dipoles and two types of combined function gradient magnets. All three types were designed with magnetic-field calculation program POISSON, using the same exterior dimensions and coil package. The design goal of +-1% momentum acceptance for the transport line required a wide horizontal aperture, with a much-smaller vertical aperture for economy. Two prototypes of one gradient magnet were built, and a facility constructed to measure them and the later production magnets. Measurements were done using both a long coil and a point coil (Rawson-Lush gaussmeter). Preliminary results show ..delta..B/B < 0.2 x 10/sup -3/, ..delta..G/G < 0.3 x 10/sup -2/, and ..delta..B/sub 2//B < 0.3 x 10/sup -4/ cm/sup -2/ over the beam aperture. Due to end effects, the actual gradient differs from the design gradient by 1%, which has been compensated for in the beam-line design.

  7. Optimization of solenoid based low energy beam transport line for high current H+ beams

    Science.gov (United States)

    Pande, R.; Singh, P.; Rao, S. V. L. S.; Roy, S.; Krishnagopal, S.

    2015-02-01

    A 20 MeV, 30 mA CW proton linac is being developed at BARC, Mumbai. This linac will consist of an ECR ion source followed by a Radio Frequency Quadrupole (RFQ) and Drift tube Linac (DTL). The low energy beam transport (LEBT) line is used to match the beam from the ion source to the RFQ with minimum beam loss and increase in emittance. The LEBT is also used to eliminate the unwanted ions like H2+ and H3+ from entering the RFQ. In addition, space charge compensation is required for transportation of such high beam currents. All this requires careful design and optimization. Detailed beam dynamics simulations have been done to optimize the design of the LEBT using the Particle-in-cell code TRACEWIN. We find that with careful optimization it is possible to transport a 30 mA CW proton beam through the LEBT with 100% transmission and minimal emittance blow up, while at the same time suppressing unwanted species H2+ and H3+ to less than 3.3% of the total beam current.

  8. Appropriate observables for investigating narrow resonances in kaon photoproduction off a proton

    CERN Document Server

    Mart, T

    2011-01-01

    The existence of non-strange partner of pentaquark, the J^p = 1/2^+ narrow resonance, has been investigated by utilizing kaon photoproduction off a proton. It is found that the corresponding mass is 1650 MeV and the appropriate observables for investigating this resonance are the recoiled hyperon polarization, the beam-recoil double polarization C_x, and differential cross section at backward angles. Future kaon photoproduction experiments at low energies should focus on these observables.

  9. Experimental Program for the CLIC test facility 3 test beam line

    CERN Document Server

    Adli, E; Dobert, S; Olvegaard, M; Schulte, D; Syratchev, I; Lillestol, Reidar

    2010-01-01

    The CLIC Test Facility 3 Test Beam Line is the first prototype for the CLIC drive beam decelerator. Stable transport of the drive beam under deceleration is a mandatory component in the CLIC two-beam scheme. In the Test Beam Line more than 50% of the total energy will be extracted from a 150 MeV, 28 A electron drive beam, by the use of 16 power extraction and transfer structures. A number of experiments are foreseen to investigate the drive beam characteristics under deceleration in the Test Beam Line, including beam stability, beam blow up and the efficiency of the power extraction. General benchmarking of decelerator simulation and theory studies will also be performed. Specially designed instrumentation including precision BPMs, loss monitors and a time-resolved spectrometer dump will be used for the experiments. This paper describes the experimental program foreseen for the Test Beam Line, including the relevance of the results for the CLIC decelerator studies.

  10. Photoproduction of the kaon(+)kaon(-)(1750)

    Science.gov (United States)

    Mitchell, Ryan Edward

    2003-07-01

    While photoproduction has often been advertised as an important environment in which to study light meson spectroscopy, solid experimental results are sparse. In fact, beyond the relatively straightforward photoproduction of the rho, o, and φ mesons, the few results of exclusive photoproduction that do exist are poorly understood, and several, perhaps, have even been misinterpreted. After extensively reviewing the sometimes tenuous history of the exclusive photoproduction of the "rho'(1600)," the "opi0(1250)," the "o(1650)," and the "K+K -(1750)," new results from the E831/FOCUS photoproduction experiment at Fermilab are presented which address the interpretation of the K+K-(1750). This enhancement in low-pT K +K- pairs at a mass near 1750 MeV/c2 has been observed by several previous photoproduction experiments, but, despite several apparent inconsistencies, it has always been interpreted as the JPC = 1-- φ(1680) meson. With nearly two orders of magnitude more events than any previous observation of the K+ K-(1750), and based on precise measurements of its mass and width, and its absence from the K* K final state, the FOCUS data can finally render this interpretation implausible. In addition, several steps have been taken towards establishing a new interpretation. Based on limited angular analyses of its decay and the beam energy dependence of its production, we argue that, in the absence of any wild interference scenarios, the K+ K-(1750) has JPC ≠ 1--, and, in fact, the most likely assignment appears to be 2++. It is hoped that this work can help set the stage for future reevaluations and new insights in photoproduction.

  11. The Beam Position System of the CERN Neutrino to Gran Sasso Proton Beam Line

    CERN Document Server

    Bogey, T

    2008-01-01

    The CERN Neutrino to Gran Sasso (CNGS) experiment uses 400GeV protons extracted from the SPS, which travel along 825 meters of beam line before reaching the CNGS target. This beam line is equipped with 23 BPMs capable of measuring both the horizontal and vertical position of the beam. The final BPM is linked to the target station and due to radiation constraints has been designed to work in air. This contribution will give an overview of the BPMs used in the transfer line. It will also provide a detailed explanation of their logarithmic amplifier based acquisition electronics, which consists of an autotriggered sequencer controlling an integrator, the A/D conversion and the Manchester encoded transmission of the digital data to the surface. At the surface the digital data is acquired using the Digital Acquisition Board (DAB) developed by TRIUMF (Canada) for the LHC BPM system. Results from both laboratory measurements and beam measurements during the 2006 CNGS run will also be presented.

  12. Base Line Design for a Beta/Beam Neutrino Facility

    CERN Document Server

    Benedikt, Michael

    2004-01-01

    The term beta-beam has been coined for the production of pure beams of electron neutrinos or their antiparticles through the decay of radioactive ions circulating in a storage ring. The neutrino source itself consists of a high-energy storage ring (gamma ~150), with long straight sections in line with the experiment(s). The radioactive ions (6He and 18Ne) will be produced in an ISOL type target system. Due to the short life times of around 1 s at rest, the beam needs to be accelerated as quickly as possible. For this a staged system of accelerators is proposed. The chain starts with a linac followed by a rapid cycling synchrotron for acceleration up to ~300 MeV/u. For further acceleration the existing PS and SPS machines are used. Finally, after acceleration to SPS top energy, the ions are transferred to a decay ring where they are merged with the existing bunches through a longitudinal stacking procedure. The baseline design of the beta-beam facility will be presented together with its major problems. Potent...

  13. Particle Identification with Cherenkov detectors in the 2011 CALICE Tungsten Analog Hadronic Calorimeter Test Beam at the CERN SPS

    CERN Document Server

    Dannheim, D; Klempt, W; Lucaci Timoce, A; van der Kraaij, E

    2013-01-01

    In 2011 the CALICE Tungsten Analog Hadronic Calorimeter prototype (W-AHCAL) was exposed to mixed beams of electrons, pions, kaons and protons with momenta from 10 to 300 GeV in the CERN SPS H8 beam line. The selection of pion, kaon and proton samples is based on the information obtained from two Cherenkov threshold counters. This note presents the strategy for the particle identification, as well as the calibration, operation and analysis of the Cherenkov counters. Efficiency and sample-purity estimates are given for the data selected for the W-AHCAL data analysis.

  14. Kaon Flavour Physics Strikes Back

    CERN Document Server

    Buras, Andrzej J

    2016-01-01

    In this short presentation I emphasize the increased importance of kaon flavour physics in the search for new physics (NP) that we should witness in the rest of this decade and in the next decade. The main actors will be the branching ratios for the rare decays $K^+\\rightarrow\\pi^+\

  15. CP violation in kaon decays

    CERN Document Server

    D'Ambrosio, G

    1996-01-01

    We review the Standard Model predictions of CP violation in kaon decays. We present an elementary introduction to Chiral Perturbation Theory, four--quark effective hamiltonians and the relation among them. Particular attention is devoted to $K\\to 3\\pi$, $K\\to 2\\pi \\gamma$ and $K\\to \\pi \\bar{f} f$ decays.

  16. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B. [Los Alamos National Laboratory, M. S. H808, Los Alamos, New Mexico 87545 (United States)

    1995-05-05

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  17. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Science.gov (United States)

    Gilpatrick, J. D.; Carter, H.; Plum, M.; Power, J. F.; Rose, C. R.; Shurter, R. B.

    1995-05-01

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  18. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B.

    1995-12-31

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  19. Searches for very rare decays of kaons

    Energy Technology Data Exchange (ETDEWEB)

    Lang, K. [Univ. of Texas, Austin, TX (United States)

    1997-01-01

    The physics motivation for searches for very rare kaon decays, either forbidden or suppressed within the Standard Model, is briefly discussed. Simple arguments conclude that such searches probe possible new forces at a 200 TeV mass scale or constitute a precision test of the electroweak model. The examples of such process are decays of K{sub L}{sup 0} {yields} {mu} {sup {+-}}e{sup -+}, K{sup +} {yields} {pi}{sup +} {mu}{sup +} e{sup -}, K{sub L}{sup 0} {yields} {mu}{sup +} {mu}{sup -}, and K{sup +} {yields} {pi} {yields} {pi}{sup +}{nu}{bar {nu}}. We present the current experimental status and describe the new efforts to reach sensitivities down to one part in 10{sup 12}. The discussion is focused on the experimental program at the Alternating Gradient Synchrotron at Brookhaven National Laboratory, where intense beams make such studies possible.

  20. The effects of beam line pressure on the beam quality of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V., E-mail: ville.toivanen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland); Steczkiewicz, O.; Tarvainen, O.; Ropponen, T.; Arje, J.; Koivisto, H. [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-05-01

    The results of a series of measurements studying the possibility to use neutral gas feeding into the beam line as a way to improve the quality of the heavy ion beams produced with an electron cyclotron resonance ion source (ECRIS) are presented. Significant reduction of the beam spot size and emittance can be achieved with this method. The observed effects are presumably due to increased space charge compensation degree of the ion beam in the beam line section between the ion source and the analyzing magnet. This is the region where the neutral gas was injected. It is shown that the effects are independent of the ion source tuning. Transmission measurements through the beam line and K-130 cyclotron have been carried out to study the effects of improved ion beam quality to the transmission efficiency.

  1. Development of BPM/BLM DAQ System for KOMAC Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Kim, Jae-Ha; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The proton beam is accelerated from 3 MeV to 100 MeV through 11 DTL tanks. The KOMAC installed 10 beam lines, 5 for 20-MeV beams and 5 for 100-MeV beams. The proton beam is transmitted to two target room. The KOMAC has been operating two beam lines, one for 20 MeV and one for 100 MeV. New beam line, RI beam line is under commissioning. A Data Acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. A data acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. The DAQ digitizes beam signal and the sampling is synchronized with a reference signal which is an external trigger for beam operation. The digitized data is accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. The beam monitoring system integrates BLM and BPM signals into the control system and offers realtime data to operators. The IOC, which is implemented with Linux and a PCI driver, supports data acquisition as a very flexible solution.

  2. Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following a beam line

    NARCIS (Netherlands)

    van Goethem, M. J.; van der Meer, R.; Reist, H. W.; Schippers, J. M.

    2009-01-01

    Monte Carlo simulations based on the Geant4 simulation toolkit were performed for the carbon wedge degrader used in the beam line at the Center of Proton Therapy of the Paul Scherrer Institute (PSI). The simulations are part of the beam line studies for the development and understanding of the GANTR

  3. Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, C.; Halama, H.; Thomlinson, W.

    1986-10-01

    Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

  4. Beam line shielding calculations for an Electron Accelerator Mo-99 production facility

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-03

    The purpose of this study is to evaluate the photon and neutron fields in and around the latest beam line design for the Mo-99 production facility. The radiation dose to the beam line components (quadrupoles, dipoles, beam stops and the linear accelerator) are calculated in the present report. The beam line design assumes placement of two cameras: infra red (IR) and optical transition radiation (OTR) for continuous monitoring of the beam spot on target during irradiation. The cameras will be placed off the beam axis offset in vertical direction. We explored typical shielding arrangements for the cameras and report the resulting neutron and photon dose fields.

  5. Characterization of a tagged $\\gamma$-ray beam line at the DAFNE Beam Test Facility

    CERN Document Server

    Cattaneo, P W; Boffelli, F; Bulgarelli, A; Buonomo, B; Chen, A W; D’Ammando, F; FoggettA, L; Froysland, T; Fuschino, F; Galli, M; Gianotti, F; Giuliani, A; Longo, F; Marisaldi, M; Mazzitelli, G; Pellizzoni, A; Prest, M; Pucella, G; Quintieri, L; Rappoldi, A; Tavani, M; Trifoglio, M; Trois, A; Valente, P; Vallazza, E; Vercellone, S; Zambra, A; Barbiellini, G; Caraveo, P; Cocco, V; Costa, E; De Paris, G; Del Monte, E; Di Cocco, G; Donnarumma, I; Evangelista, Y; Feroci, M; Ferrari, A; Fiorini, M; Labanti, C; Lapshov, I; Lazzarotto, F; Lipari, P; Mastropietro, M; Mereghetti, S; Morelli, E; Moretti, E; Morselli, A; Pacciani, L; Perotti, F; Piano, G; Picozza, P; Pilia, M; Porrovecchio, G; Rapisarda, M; Rubini, A; Sabatini, S; Soffitta, P; Striani, E; Vittorini, V; Zanello, D; Colafrancesco, S; Giommi, P; Pittori, C; Santolamazza, P; Verrecchia, F; Salotti, L

    2012-01-01

    At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a γ-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the γ rays. A tagged γ-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating γ-rays through bremsstrahlung in a position-sensitive target. The γ-ray energy is deduced by difference with the post-bremsstrahlung electron energy [1] and [2]. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon be...

  6. Charged Kaon Mass Measurement using the Cherenkov Effect

    Energy Technology Data Exchange (ETDEWEB)

    Graf, N.; /Indiana U.; Lebedev, A.; /Harvard U., Phys. Dept.; Abrams, R.J.; /Michigan U.; Akgun, U.; Aydin, G.; /Iowa U.; Baker, W.; /Fermilab; Barnes, P.D., Jr.; /LLNL, Livermore; Bergfeld, T.; /South Carolina U.; Beverly, L.; /Fermilab; Bujak, A.; /Purdue U.; Carey, D.; /Fermilab /Virginia U. /Iowa U.

    2009-09-01

    The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 GeV/c to +63 GeV/c. The measured value is 491.3 {+-} 1.7 MeV/c{sup 2}, which is within 1.4{sigma} of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.

  7. Quasifree kaon photoproduction on nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Frank Lee; T. MART; Cornelius Bennhold; Lester Wright

    2001-12-01

    Investigations of the quasifree reaction A({gamma}, K Y)B are presented in the distorted wave impulse approximation (DWIA). For this purpose, we present a revised tree-level model of elementary kaon photoproduction that incorporates hadronic form factors consistent with gauge invariance, uses SU(3) values for the Born couplings and uses resonances consistent with multi-channel analyses. The potential of exclusive quasifree kaon photoproduction on nuclei to reveal details of the hyperon-nucleus interaction is examined. Detailed predictions for the coincidence cross section, the photon asymmetry, and the hyperon polarization and their sensitivities to the ingredients of the model are obtained for all six production channels. Under selected kinematics these observables are found to be sensitive to the hyperon-nucleus final state interaction. Some polarization observables are found to be insensitive to distortion effects, making them ideal tools to search for possible medium modifications of the elementary amplitude.

  8. KTAG: The Kaon Identification Detector for CERN experiment NA62

    Science.gov (United States)

    Fry, J. R.

    2016-07-01

    In the study of ultra-rare kaon decays, CERN experiment NA62 exploits an unseparated monochromatic (75 GeV/c) beam of charged particles of flux 800 MHz, of which 50 MHz are K+. Kaons are identified with more than 95% efficiency, a time resolution of better than 100 ps, and misidentification of less than 10-4 using KTAG, a differential, ring-focussed, Cherenkov detector. KTAG utilises 8 sets of 48 Hamamatsu PMTs, of which 32 are of type 9880 and 16 of type 7400, with signals fed directly to the differential inputs of NINO front-end boards and then to TDC cards within the TEL62 system. Leading and trailing edges of the PMT signal are digitised, enabling slewing corrections to be made, and a mean hit rate of 5 MHz per PMT is supported. The electronics is housed within a cooled and insulated Faraday cage with environmental monitoring capabilities.

  9. CEBAF at higher energies and the kaon electromagnetic form factor

    Energy Technology Data Exchange (ETDEWEB)

    Baker, O.K.

    1994-04-01

    The electromagnetic production of strangeness, the physics of exciting systems having strangeness degrees of freedom (production of hadrons with one or more strange constituent quarks) using electromagnetic probes (real or virtual photons), is one of the frontier areas of research which will be investigated at the Continuous Electron Beam Accelerator Facility (CEBAF) when it becomes operational. CEBAF is expected to have an important impact upon this field of research using its specialized set of detection instruments and high quality electron beam. This paper focusses upon one aspect of the associated production of strangeness - the determination of the kaon electromagnetic form factor at high squared momentum transfers.

  10. Bayesian analysis for kaon photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Marsainy, T., E-mail: tmart@fisika.ui.ac.id; Mart, T., E-mail: tmart@fisika.ui.ac.id [Department Fisika, FMIPA, Universitas Indonesia, Depok 16424 (Indonesia)

    2014-09-25

    We have investigated contribution of the nucleon resonances in the kaon photoproduction process by using an established statistical decision making method, i.e. the Bayesian method. This method does not only evaluate the model over its entire parameter space, but also takes the prior information and experimental data into account. The result indicates that certain resonances have larger probabilities to contribute to the process.

  11. Optical substrate materials for synchrotron radiation beam lines

    Science.gov (United States)

    Howells, Malcolm R.; Paquin, Roger A.

    1997-09-01

    We consider the materials choices available for making optical substrates for synchrotron radiation beam lines. We find that currently the optical surfaces can only be polished to the required finish in fused silica and other glasses, silicon, CVD silicon carbide, electroless nickel and 17-4 PH stainless steel. Substrates must therefore be made of one of these materials or of a metal that can be coated with electroless nickel. In the context of material choices for mirrors we explore the issues of dimensional stability, polishing, bending, cooling, and manufacturing strategy. We conclude that metals are best from an engineering and cost standpoint while the ceramics are best from a polishing standpoint. We then give discussions of specific materials as follows: silicon carbide, silicon, electroless nickel, GlidcopTM, aluminum, precipitation- hardening stainless steel, mild steel, invar and superinvar. Finally we summarize conclusions and propose ideas for further research.

  12. Renormalisation Group Flow and Kaon Condensation

    CERN Document Server

    Krippa, Boris

    2016-01-01

    Functional renormalisation group approach is applied to a system of kaons with finite chemical potential. A set of approximate flow equations for the effective couplings is derived and solved. At high scale the system is found to be at the normal phase whereas at some critical value of the running scale it undergoes the phase transition (PT) to the phase with a spontaneously broken symmetry with the kaon condensate as an order parameter. The value of the condensate turns out to be quite sensitive to the kaon-kaon scattering length.

  13. The transverse momentum dependence of charged kaon Bose–Einstein correlations in the SELEX experiment

    Directory of Open Access Journals (Sweden)

    G.A. Nigmatkulov

    2016-02-01

    Full Text Available We report the measurement of the one-dimensional charged kaon correlation functions using 600GeV/c Σ−, π− and 540GeV/c p beams from the SELEX (E781 experiment at the Fermilab Tevatron. K±K± correlation functions are studied for three transverse pair momentum, kT, ranges and parameterized by a Gaussian form. The emission source radii, R, and the correlation strength, λ, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.

  14. The transverse momentum dependence of charged kaon Bose-Einstein correlations in the SELEX experiment

    Science.gov (United States)

    Nigmatkulov, G. A.; Ponosov, A. K.; Akgun, U.; Alkhazov, G.; Amaro-Reyes, J.; Asratyan, A.; Atamantchouk, A. G.; Ayan, A. S.; Balatz, M. Y.; Blanco-Covarrubias, A.; Bondar, N. F.; Cooper, P. S.; Dauwe, L. J.; Davidenko, G. V.; Dersch, U.; Dolgolenko, A. G.; Dzyubenko, G. B.; Edelstein, R.; Emediato, L.; Endler, A. M. F.; Engelfried, J.; Eschrich, I.; Escobar, C. O.; Estrada, N.; Evdokimov, A. V.; Filimonov, I. S.; Flores-Castillo, A.; Garcia, F. G.; Giller, I.; Golovtsov, V. L.; Gouffon, P.; Gülmez, E.; Iori, M.; Jun, S. Y.; Kaya, M.; Kilmer, J.; Kim, V. T.; Kochenda, L. M.; Konorov, I.; Kozhevnikov, A. P.; Krivshich, A. G.; Krüger, H.; Kubantsev, M. A.; Kubarovsky, V. P.; Kulyavtsev, A. I.; Kuropatkin, N. P.; Kurshetsov, V. F.; Kushnirenko, A.; Lach, J.; Landsberg, L. G.; Larin, I.; Leikin, E. M.; López-Hinojosa, G.; Lungov, T.; Maleev, V. P.; Mao, D.; Mathew, P.; Mattson, M.; Matveev, V.; McCliment, E.; Moinester, M. A.; Molchanov, V. V.; Morelos, A.; Nemitkin, A. V.; Neoustroev, P. V.; Newsom, C.; Nilov, A. P.; Nurushev, S. B.; Ocherashvili, A.; Onel, Y.; Ozkorucuklu, S.; Penzo, A.; Petrenko, S. V.; Procario, M.; Prutskoi, V. A.; Razmyslovich, B. V.; Romanov, D. A.; Rud, V. I.; Russ, J.; Sánchez-López, J. L.; Savchenko, A. A.; Simon, J.; Sinev, G. V.; Sitnikov, A. I.; Smith, V. J.; Srivastava, M.; Steiner, V.; Stepanov, V.; Stutte, L.; Svoiski, M.; Tarasov, V. V.; Terentyev, N. K.; Torres, I.; Uvarov, L. N.; Vasiliev, A. N.; Vavilov, D. V.; Vázquez-Jáuregui, E.; Verebryusov, V. S.; Victorov, V. A.; Vishnyakov, V. E.; Vorobyov, A. A.; Vorwalter, K.; You, J.; Zukanovich-Funchal, R.

    2016-02-01

    We report the measurement of the one-dimensional charged kaon correlation functions using 600GeV / cΣ-, π- and 540GeV / cp beams from the SELEX (E781) experiment at the Fermilab Tevatron. K±K± correlation functions are studied for three transverse pair momentum, kT, ranges and parameterized by a Gaussian form. The emission source radii, R, and the correlation strength, λ, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.

  15. The transverse momentum dependencies of charged kaon Bose-Einstein correlations in the SELEX experiment

    CERN Document Server

    Nigmatkulov, G A; Akgun, U; Alkhazov, G; Amaro-Reyes, J; Asratyan, A; Atamantchouk, A G; Ayan, A S; Balatz, M Y; Blanco-Covarrubias, A; Bondar, N F; Cooper, P S; Dauwe, L J; Davidenko, G V; Dersch, U; Dolgolenko, A G; Dzyubenko, G B; Edelstein, R; Emediato, L; Endler, A M F; Engelfried, J; Eschrich, I; Escobar, C O; Estrada, N; Evdokimov, A V; Filimonov, I S; Flores-Castillo, A; Garcia, F G; Golovtsov, V L; Gouffon, P; Gülmez, E; Iori, M; Jun, S Y; Kaya, M; Kilmer, J; Kim, V T; Kochenda, L M; Konorov, I; Kozhevnikov, A P; Krivshich, A G; Krüger, H; Kubantsev, M A; Kubarovsky, V P; Kulyavtsev, A I; Kuropatrkin, N P; Kurshetsov, V F; Kushnirenko, A; Lach, J; Landsberg, L G; Larin, I; Leikin, E M; López-Hinojosa, G; Lungov, T; Maleev, V P; Mao, D; Mathew, P; Mattson, M; Matveev, V; McCliment, E; Moinester, M A; Molchanov, V V; Morelos, A; Nemitkin, A V; Neoustroev, P V; Newsom, C; Nilov, A P; Nurushev, S B; Ocherashvili, A; Onel, Y; Ozkorucuklu, S; Penzo, A; Petrenko, S V; Procario, M; Prutskoi, V A; Razmyslovich, B V; Romanov, D A; Rud, V I; Russ, J; Sánchez-López, J L; Savchenko, A A; Simon, J; Sinev, G V; Sitnikov, A I; Smith, V J; Srivastava, M; Steiner, V; Stepanov, V; Stutte, L; Svoiski, M; Tarasov, V V; Terentyev, N K; Torres, I; Uvarov, L N; Vasiliev, A N; Vavilov, D V; Vázquez-Jáuregui, E; Verebryusov, V S; Victorov, V A; Vishnyakov, V E; Vorobyov, A A; Vorwalter, K; You, J; Zukanovich-Funchal, R

    2015-01-01

    We report on the measurement of the charged kaon correlation functions $k_T$ dependencies using 600 GeV/$c$ $\\Sigma^-$, $\\pi^-$ and 540 GeV/$c$ $p$ beams from the SELEX (E781) experiment at Tevatron. One-dimentional $K^{ch}K^{ch}$ correlation functions are constructed in three transverse momentum ranges. The emission source parameters $\\lambda$ and $R$ are extracted. The analysis shows a decrease of the source radii with the kaon pair transverse momentum for all beam types

  16. Beam dynamics and error study of the medium energy beam transport line in the Korea Heavy-Ion Medical Accelerator

    Science.gov (United States)

    Kim, Chanmi; Kim, Eun-San; Hahn, Garam

    2016-11-01

    The Korea Heavy Ion Medical Accelerator consists of an injector and a synchrotron for an ion medical accelerator that is the first carbon-ion therapy system in Korea. The medium energy beam transport(MEBT) line connects the interdigital H-mode drift tube linac and the synchrotron. We investigated the beam conditions after the charge stripper by using the LISE++ and the SRIM codes. The beam was stripped from C4+ into C6+ by using the charge stripper. We investigated the performance of a de-buncher in optimizing the energy spread and the beam distribution in z-dW/W (direction of beam progress-beam and energy) phase. We obtained the results of the tracking simulation and the error analysis by using the TRACK code. Possible misalignments and rotations of the magnets were considered in the simulations. States of the beam were examined when errors occurred in the magnets by the applying analytic fringe field model in TRACK code. The condition for the beam orbit was optimized by using correctors and profile monitors to correct the orbit. In this paper, we focus on the beam dynamics and the error studies dedicated to the MEBT beam line and show the optimized beam parameters for the MEBT.

  17. New magnet transport system for the LHC beam transfer lines

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system (pictured here in one of the tunnels) is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The lead vehicle is powered by an electric rail set into the roof of the tunnel. The system is backed up by electrical batteries that enable it to operate in the absence of an outside power source or in the event of power failure. Last but not least, for the long-distance transport of magnets, it can be optically guided by a line traced on the tunnel floor. The convoy moves through the particularly narr...

  18. Lattice design and beam dynamics studies of the high energy beam transport line in the RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hyunchang, E-mail: hcjin@ibs.re.kr; Jang, Ji-Ho; Jang, Hyojae; Jeon, Dong-O

    2015-12-01

    In RAON heavy ion accelerator, beams generated by superconducting electron cyclotron resonance ion source (ECR-IS) or Isotope Separation On-Line (ISOL) system are accelerated by lower energy superconducting linac and high energy superconducting linac. The accelerated beams are used in the high energy experimental hall which includes bio-medical and muon-SR facilities, after passing through the high energy beam transport lines. At the targets of those two facilities, the stable and small beams meeting the requirements rigorously are required in the transverse plane. Therefore the beams must be safely sent to the targets and simultaneously satisfy the two requirements, the achromatic condition and the mid-plane symmetric condition, of the targets. For this reason, the lattice design of the high energy beam transport lines in which the long deflecting sections are included is considered as a significant issue in the RAON accelerator. In this paper, we will describe the calculated beam optics satisfying the conditions and present the result of particle tracking simulations with the designed lattice of the high energy beam transport lines in the RAON accelerator. Also, the orbit distortion caused by the machine imperfections and the orbit correction with correctors will be discussed.

  19. Measurement of the charged kaon mass with the MIPP RICH

    Energy Technology Data Exchange (ETDEWEB)

    Graf, Nicholas J. [Indiana Univ., Bloomington, IN (United States)

    2008-08-01

    The currently accepted value of the charged kaon mass is 493.677 ± 0.013 MeV (26 ppm). It is a weighted average of six measurements, most of which use kaonic atom X-ray energy techniques. The two most recent and precise results dominate the average but differ by 122 ppm. Inconsistency in the data set needs to be resolved, preferably using independent techniques. One possibility uses the Cherenkov effect. A measurement of the charged kaon mass using this technique is presented. The data was taken with the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory using a tagged beam of protons, kaons, and pions ranging in momentum from 37 GeV/c to 63 GeV/c. The measured value is 491.3 ± 1.7 MeV. This is within 1.4σ of the current value. An improvement in precision by a factor of 35 would make this technique competitive for resolving the ambiguity in the X-ray data.

  20. Induced polarization of Λ(1116) in kaon electroproduction with CLAS

    Science.gov (United States)

    Gabrielyan, Marianna; Raue, Brian; Carman, Daniel S.; Park, Kijun

    2013-10-01

    The CLAS Collaboration is using the p(e,e'K+p)π- reaction to perform a measurement of the induced polarization of the electroproduced Λ(1116). The parity-violating weak decay of the Λ into p&pgr- (64%) allows extraction of the recoil polarization of the Λ. This study uses the CEBAF Large Acceptance Spectrometer (CLAS) to detect the scattered electron, the kaon, and the decay proton. CLAS allows for a large kinematic acceptance with 0.8 ≤ Q2 ≤ 3.5 GeV2, 1.6 ≤ W ≤ 3.0 GeV, as well as the kaon scattering angle. In this experiment a 5.5 GeV electron beam was incident upon an unpolarized liquid-hydrogen target. The goal is to map out the kinematic dependencies for this polarization observable to provide new constraints for theoretical models of the electromagnetic production of kaon-hyperon final states. Along with previously published photo- and electro-production cross sections and polarization observables from CLAS, SAPHIR, and GRAAL, these data are needed in a coupled-channel analysis to identify previously unobserved s-channel resonances.

  1. RESULTS FROM THE COMMISSIONING OF THE NSRL BEAM TRANSFER LINE AT BNL.

    Energy Technology Data Exchange (ETDEWEB)

    TSOUPAS,N.; BELLAVIA,S.; BONATI,R.; ET AL.

    2004-07-05

    The NASA SPACE RADIATION LABORATORY (NSRL) has been constructed and started operations at the Brookhaven National Laboratory in 2003. The NSRL facility will be used by NASA to perform radiation effect studies on materials and biological samples for the space program. The facility utilizes proton and heavy-ion beams of energies from 50 to 3000 MeVln which are accelerated by the AGS Booster synchrotron accelerator. To date, {sup 1}H, {sup 12}C, {sup 56}Fe, {sup 48}Ti, and {sup 197}Au ion beams of various magnetic rigidities have been extracted from the Booster, and transported by the NSRL beam transport line to the sample location which is located 100 m from the extraction point. The NSRL beam transport line has been designed to employ octupole magnetic elements which transform the normal (Gaussian) beam distribution at the location of the sample into a beam with rectangular cross section, and uniformly distributed over the sample. When using the octupole magnetic elements to obtain the uniform beam distribution on the sample, no beam-collimation is applied at any location along the NSRL beam transport line and the beam focusing on the sample is purely magnetic. The main subject of this paper will be the performance of the octupoles (third order optics) in obtaining uniform beam distributions at the target of the NSRL beam transport line.

  2. Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation

    Institute of Scientific and Technical Information of China (English)

    杨尧; 赵红卫; 原有进; 冯玉成; 孙良亭; 方兴; 卢旺; 张文慧; 曹云; 张雪珍

    2015-01-01

    The operation of the HIRFL accelerator has shown that the beam transmission efficiency of the sector focusing cyclotron (SFC) injector line is rather poor. Beam simulations have been performed to investigate the possible causes for this low transmission. It is predicted that the property of transversal coupling of the ion beam from electron cyclotron resonance (ECR) ion source can be an important factor to degrade the beam quality by increasing the beam emittance, resulting in a serious particle loss. An improved operation scheme for the SECRAL associated line has been proposed, and the corresponding experiment was carried out. This paper presents the test results.

  3. RI-induced reaction studies by new energy-degrading beam line, OEDO

    Science.gov (United States)

    Michimasa, Shin'ichiro

    2014-09-01

    The RI beam factory (RIBF) has expanded variety of accessible nuclei, and provides very intense RI beams. However, the beams are energy range of above 100 MeV/u, and are not necessarily suitable to some kinds of nuclear reactions. Therefore, deceleration of intense RI beams from RIBF open potentially new scientific opportunities to access various states in exotic nuclei by using characteristics probes, such as transfer reactions at several ten MeV/u and fusion reactions at several MeV/u. For energy degrading of nuclear beams, the degrader is generally used. This method easily controls beam energy, while multiple scattering effect and energy straggling in the material broaden the beam spot size at the downstream foci. Therefore, a key issue for reaction measurements is achievement of ion transport to reduce the beam emittance at the secondary target. For this purpose, CNS has set up OEDO (Optimized Energy Degrading Optics for RI beam) project for production of high-quality low energy RI beams. The OEDO beam line scheme is planned to be achieved by re-arrangement of magnets of the high-resolution beam line, where the SHARAQ spectrometer is useful as a spectrograph for low-energy reaction spectroscopy. In this presentation, I will discuss scientific opportunities in the OEDO beam line and the SHARAQ spectrometer.

  4. REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.

    Energy Technology Data Exchange (ETDEWEB)

    FOERSTER,C.

    1999-05-01

    Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of {approximately} 1 x 10{sup {minus}10} Torr without beam and {approximately} 1 x 10{sup {minus}9} Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware

  5. Beam chopper For the Low-Energy Undulator Test Line (LEUTL) in the APS

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Y.; Wang, J.; Milton, S.; Teng, L. [and others

    1997-08-01

    The low-energy undulator test line (LEUTL) is being built and will be tested with a short beam pulse from an rf gun in the Advanced Photon Source (APS) at the Argonne National Laboratory. In the LEUTL a beam chopper is used after the rf gun to deflect the unwanted beam to a beam dump. The beam chopper consists of a permanent magnet and an electric deflector that can compensate for the magnetic deflection. A 30-kV pulsed power supply is used for the electric deflector. The chopper subsystem was assembled and tested for beamline installation. The electrical and beam properties of the chopper assembly are presented.

  6. An after-market, five-port vertical beam line extension for the PETtrace

    DEFF Research Database (Denmark)

    Barnhart, T. E.; Engle, J. W.; Severin, Gregory

    2012-01-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target...... positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates. © 2012 American Institute of Physics...

  7. An after-market, five-port vertical beam line extension for the PETtrace

    Science.gov (United States)

    Barnhart, T. E.; Engle, J. W.; Severin, G. W.; Valdovinos, H. F.; Gagnon, K.; Nickles, R. J.

    2012-12-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates.

  8. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Science.gov (United States)

    Zhang, Xu; Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming; Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN-LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  9. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xu, E-mail: emmazhang103@gmail.com [China Institute of Atomic Energy (China); Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming [China Institute of Atomic Energy (China); Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir [BEST Cyclotron Inc (Canada)

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN–LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  10. DIAGNOSIS OF THE LOW EMITTANCE BEAM IN ATF DR EXTRACTION LINE

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, Douglas

    2003-05-06

    The ATF (Accelerator Test Facility in KEK) damping ring has been designed to produce the low emittance beam required by future linear colliders. In the design, the normalized vertical emittance of the ATF damping ring is 3.0E-8 radm which corresponds to the vertical beam size of about 10 micron in the extraction line. The emittance of the beam extracted from the ATF damping ring is measured with four wire scanners located in a dispersion free region of the extraction line. The optics of the extraction line is also studied. We will report the method and the result of the emittance measurement at the extraction line.

  11. A high-resolution x-ray spectrometer for a kaon mass measurement

    Science.gov (United States)

    Phelan, Kevin; Suzuki, Ken; Zmeskal, Johann; Tortorella, Daniele; Bühler, Matthias; Hertrich, Theo

    2017-02-01

    The ASPECT consortium (Adaptable Spectrometer Enabled by Cryogenic Technology) is currently constructing a generalised cryogenic platform for cryogenic detector work which will be able to accommodate a wide range of sensors. The cryogenics system is based on a small mechanical cooler with a further adiabatic demagnetisation stage and will work with cryogenic detectors at sub-Kelvin temperatures. The commercial aim of the consortium is to produce a compact, user-friendly device with an emphasis on reliability and portability which can easily be transported for specialised on-site work, such as beam-lines or telescope facilities. The cryogenic detector platform will accommodate a specially developed cryogenic sensor, either a metallic magnetic calorimeter or a magnetic penetration-depth thermometer. The detectors will be designed to work in various temperatures regions with an emphasis on optimising the various detector resolutions for specific temperatures. One resolution target is of about 10 eV at the energies range typically created in kaonic atoms experiments (soft x-ray energies). A following step will see the introduction of continuous, high-power, sub-Kelvin cooling which will bring the cryogenic basis for a high resolution spectrometer system to the market. The scientific goal of the project will produce an experimental set-up optimised for kaon-mass measurements performing high-resolution x-ray spectroscopy on a beam-line provided foreseeably by the J-PARC (Tokai, Japan) or DAΦNE (Frascati, Italy) facilities.

  12. A beam position monitor for the diagnostic line in MEBT2 of J-PARC linac

    Science.gov (United States)

    Miura, A.; Tamura, J.; Kawane, Y.

    2017-07-01

    In the linac of the Japan Proton Accelerator Research Complex (J-PARC), the neutral hydrogen (H0) beam from the negative hydrogen ion (H-) beam is one of key issues in mitigating beam losses. To diagnose H0 particles, we installed a set of beam-bump magnets to generate a chicane orbit of the H- beam. The beam position monitors (BPMs) in the beam line are used for orbit correction to maintain the beam displacement within 2.0 mm from the duct center. To measure the beam displacement under different drive currents of the beam-bump magnets, a new wide-range BPM was designed and manufactured to evaluate the horizontal beam position by using a correction function to compensate for non-linearity. We also employed the beam profile monitor (WSM: wire scanner monitor) to measure the H- beam profile, which helped us to compare the beam position measurements. In this paper, the design and the performance of the wide-range BPM are described. In addition, we present a comparison of the beam position measured by the BPM and the WSM.

  13. Report on strangeness photoproduction experiments performed with the Neutral Kaon Spectrometer 2

    CERN Document Server

    Beckford, B; Doi, D; Fujibayashi, J; Fujii, T; Fujii, Y; Futatsukawa, K; Gogami, T; Hashimoto, O; Han, Y C; Hirose, K; Hirose, S; Honda, R; Honda, R; Hosomi, K; Iguchi, A; Ishikawa, T; Kanda, H; Kaneta, M; Kaneko, Y; Kato, S; Kawama, D; Kawasaki, T; Kiyokawa, S; Koike, T; Maeda, K; Makabe, K; Maruyama, N; Matsubara, M; Miwa, K; Miyagi, Y; Nagao, S; Nakamura, S N; Okuyama, A; Shirotori, K; Sugihara, K; Suzuki, K; Tamae, T; Tamura, H; Terada, N; Tsukada, K; Yagi, K; Yamamoto, F; Yamamoto, T O; Yamazaki, H; Yonemoto, Y

    2012-01-01

    An experiment designed to investigate the strangeness photoproduction process using a tagged photon beam in the energy range of 0.90 -1.08 GeV incident on a liquid deuterium target was successfully performed. The purpose of the experiment was to measure the production of neutral kaons and the lambda particles on a deuteron. The generation of photo produced particles was verified by the measurement of their decayed charged particles in the Neutral Kaon Spectrometer 2. The reconstructed invariant mass distributions were achieved by selecting events where two or more particles tracks were identified. Preliminary results are presented here.

  14. Feedback phase correction of Bessel beams in confocal line light-sheet microscopy: a simulation study.

    Science.gov (United States)

    Moosavi, S Hoda; Gohn-Kreuz, Cristian; Rohrbach, Alexander

    2013-08-10

    Confocal line detection has been shown to improve contrast in light-sheet-based microscopy especially when illuminating the sample by Bessel beams. Besides their self-reconstructing capability, the stability in propagation direction of Bessel beams allows to block the unwanted emission light from the Bessel beam's ring system. However, due to phase aberrations induced especially at the border of the specimen, Bessel beams may not propagate along lines parallel to the slit detector. Here we present a concept of how to correct the phase of each incident Bessel beam such that the efficiency of confocal line detection is improved by up to 200%-300%. The applicability of the method is verified by the results obtained from numerical simulations based on the beam propagation method.

  15. Kaon Physics at CERN – Recent Results from the NA48/2 and NA62 Experiments

    Directory of Open Access Journals (Sweden)

    Winhart Andreas

    2012-12-01

    Full Text Available This letter presents recent results from the kaon experiments NA48/2 and its successor NA62 at CERN. With samples of 2.5 × 106 Kµ3± and 4.0 × 106 Ke3± events collected by NA48/2 in 2004, precise measurements of the form factors were performed. The Chiral Perturbation Theory was tested through a new study of K± → π±γγ decays based on data taken with minimal trigger conditions. Using the beam line and detector of NA48/2 in the years 2007-2008, NA62 performed a precison measurement of the helicitysuppressed ratio of the charged kaon leptonic decay rates K± → e+ν and K± → μ+ν Using the full data set, which is about ten times larger than the previous world data sample, the total uncertainty on this ratio is only 0.4%, representing a precision test of μ – e lepton universality. Finally, the main stage of the NA62 experiment is presented. The planned measurement of the ultra rare decay K+ → π+ vv¯ $var v$ at 10% precision will provide a powerful test of the Standard Model. The experimental challenges to reach this goal require new detectors with exceptional performances.

  16. Beam Transfer Line Design for a Plasma Wakefield Acceleration Experiment (AWAKE) at the CERN SPS

    CERN Document Server

    Bracco, C; Brethoux, D; Clerc, V; Goddard, B; Gschwendtner, E; Jensen, L K; Kosmicki, A; Le Godec, G; Meddahi, M; Muggli, P; Mutin, C; Osborne, O; Papastergiou, K; Pardons, A; Velotti, F M; Vincke, H

    2013-01-01

    The world’s first proton driven plasma wakefield acceleration experiment (AWAKE) is presently being studied at CERN. The experimentwill use a high energy proton beam extracted from the SPS as driver. Two possible locations for installing the AWAKE facility were considered: the West Area and the CNGS beam line. The previous transfer line from the SPS to the West Area was completely dismantled in 2005 and would need to be fully re-designed and re-built. For this option, geometric constraints for radiation protection reasons would limit the maximum proton beam energy to 300 GeV. The existing CNGS line could be used by applying only minor changes to the lattice for the final focusing and the interface between the proton beam and the laser, required for plasma ionisation and bunch-modulation seeding. The beam line design studies performed for the two options are presented.

  17. Tomography and imaging at the PSICHE beam line of the SOLEIL synchrotron

    Science.gov (United States)

    King, A.; Guignot, N.; Zerbino, P.; Boulard, E.; Desjardins, K.; Bordessoule, M.; Leclerq, N.; Le, S.; Renaud, G.; Cerato, M.; Bornert, M.; Lenoir, N.; Delzon, S.; Perrillat, J.-P.; Legodec, Y.; Itié, J.-P.

    2016-09-01

    PSICHE (Pressure, Structure and Imaging by Contrast at High Energy) is the high-energy beam line of the SOLEIL synchrotron. The beam line is designed to study samples at extreme pressures, using diffraction, and to perform imaging and tomography for materials science and other diverse applications. This paper presents the tomograph and the use of the beam line for imaging, with emphasis on developments made with respect to existing instruments. Of particular note are the high load capacity rotation stage with free central aperture for installing large or complex samples and sample environments, x-ray mirror and filter optics for pink beam imaging, and multiple options for combining imaging and diffraction measurement. We describe how x-ray imaging techniques have been integrated into high-pressure experiments. The design and the specifications of the beam line are described, and several case studies drawn from the first user experiments are presented.

  18. The First On-line Radioactive Ion Beam from BRIF

    Institute of Scientific and Technical Information of China (English)

    CUI; Bao-qun; MA; Ying-jun; MA; Rui-gang; TANG; Bing; HUANG; Qing-hua; CHEN; Li-hua; MA; Xie

    2015-01-01

    Many of the reactions fundamentally important in nuclear physics and astrophysics can only be studied with high energy radioactive ion beams (RIBs).Radioactive ion beams offer unique opportunities to further our knowledge about the structure of the nucleus,the stellar processes.

  19. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    CERN Document Server

    Bogomilov, M.; Kolev, D.; Russinov, I.; Tsenov, R.; Vankova-Kirilova, G.; Wang, L.; Xu, F.Y.; Zheng, S.X.; Bertoni, R.; Bonesini, M.; Ferri, F.; Lucchini, G.; Mazza, R.; Paleari, F.; Strati, F.; Palladino, V.; Cecchet, G.; de Bari, A.; Capponi, M.; Cirillo, A.; Iaciofano, A.; Manfredini, A.; Parisi, M.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Mori, Y.; Kuno, Y.; Sakamoto, H.; Sato, A.; Yano, T.; Yoshida, M.; Ishimoto, S.; Suzuki, S.; Yoshimura, K.; Filthaut, F.; Garoby, R.; Gilardoni, S.; Gruber, P.; Hanke, K.; Haseroth, H.; Janot, P.; Lombardi, A.; Ramberger, S.; Vretenar, M.; Bene, P.; Blondel, A.; Cadoux, F.; Graulich, J.S.; Grichine, V.; Gschwendtner, E.; Masciocchi, F.; Sandstrom, R.; Verguilov, V.; Wisting, H.; Petitjean, C.; Seviour, R.; Alexander, J.; Charnley, G.; Collomb, N.; Griffiths, S.; Martlew, B.; Moss, A.; Mullacrane, I.; Oates, A.; Owens, P.; White, C.; York, S.; Adams, D.; Apsimon, R.; Barclay, P.; Baynham, D.E.; Bradshaw, T.W.; Courthold, M.; Drumm, P.; Edgecock, R.; Hayler, T.; Hills, M.; Ivaniouchenkov, Y.; Jones, A.; Lintern, A.; MacWaters, C.; Nelson, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rochford, J.H.; Rogers, C.; Spensley, W.; Tarrant, J.; Tilley, K.; Watson, S.; Wilson, A.; Forrest, D.; Soler, F.J.P.; Walaron, K.; Cooke, P.; Gamet, R.; Alekou, A.; Apollonio, M.; Barber, G.; Clark, D.; Clark, I.; Dobbs, A.; Dornan, P.; Fish, A.; Hare, R.; Greenwood, S.; Jamdagni, A.; Kasey, V.; Khaleeq, M.; Leaver, J.; Long, K.; McKigney, E.; Matsushita, T.; Pasternak, J.; Sashalmi, T.; Savidge, T.; Takahashi, M.; Blackmore, V.; Carlisle, T.; Cobb, J.H.; Lau, W.; Rayner, M.; Tunnell, C.D.; Witte, H.; Yang, S.; Booth, C.N.; Hodgson, P.; Howlett, L.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.; Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Ellis, M.; Kyberd, P.; Littlefield, M.; Nebrensky, J.J.; Bross, A.D.; Geer, S.; Neuffer, D.; Moretti, A.; Popovic, M.; Cummings, M.A.C.; Roberts, T.J.; DeMello, A.; Green, M.A.; Li, D.; Virostek, S.; Zisman, M.S.; Freemire, B.; Hanlet, P.; Huang, D.; Kafka, G.; Kaplan, D.M.; Snopok, P.; Torun, Y.; Blot, S.; Kim, Y.K.; Bravar, U.; Onel, Y.; Cline, D.; Fukui, Y.; Lee, K.; Yang, X.; Rimmer, R.A.; Cremaldi, L.M.; Gregoire, G.; Hart, T.L.; Sanders, D.A.; Summers, D.J.; Coney, L.; Fletcher, R.; Hanson, G.G.; Heidt, C.; Gallardo, J.; Kahn, S.; Kirk, H.; Palmer, R.B.

    2012-01-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz muon rate, with a neglible pion contamination in the beam.

  20. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    CERN Document Server

    Bogomilov, M.

    2012-01-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz muon rate, with a neglible pion contamination in the beam.

  1. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bogomilov, M.; Karadzhov, Y.; Kolev, D.; Russinov, I.; Tsenov, R.; Vankova-Kirilova, G.; Wang, L.; Xu, F. Y.; Zheng, S. X.; Bertoni, R.; Bonesini, M.; Ferri, F.; Lucchini, G.; Mazza, R.; Paleari, F.; Strati, F.; Palladino, V.; Cecchet, G.; Bari, A. de; Capponi, M.; Cirillo, A.; Iaciofano, A.; Manfredini, A.; Parisi, M.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Mori, Y.; Kuno, Y.; Sakamoto, H.; Sato, A.; Yano, T.; Yoshida, M.; Ishimoto, S.; Suzuki, S.; Yoshimura, K.; Filthaut, F.; Garoby, R.; Gilardoni, S.; Gruber, P.; Hanke, K.; Haseroth, H.; Janot, P.; Lombardi, A.; Ramberger, S.; Vretenar, M.; Bene, P.; Blondel, A.; Cadoux, F.; Graulich, J. -S; Grichine, V.; Gschwendtner, E.; Masciocchi, F.; Sandstrom, R.; Verguilov, V.; Wisting, H.; Petitjean, C.; Seviour, R.; Alexander, J.; Charnley, G.; Collomb, N.; Griffiths, S.; Martlew, B.; Moss, A.; Mullacrane, I.; Oates, A.; Owens, P.; White, C.; York, S.; Adams, D.; Apsimon, R.; Barclay, P.; Baynham, D. E.; Bradshaw, T. W.; Courthold, M.; Drumm, P.; Edgecock, R.; Hayler, T.; Hills, M.; Ivaniouchenkov, Y.; Jones, A.; Lintern, A.; MacWaters, C.; Nelson, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rochford, J. H.; Rogers, C.; Spensley, W.; Tarrant, J.; Tilley, K.; Watson, S.; Wilson, A.; Forrest, D.; Soler, F. J. P.; Walaron, K.; Cooke, P.; Gamet, R.; Alekou, A.; Apollonio, M.; Barber, G.; Beuselinck, R.; Clark, D.; Clark, I.; Colling, D.; Dobbs, A.; Dornan, P.; Fayer, S.; Fish, A.; Hare, R.; Greenwood, S.; Jamdagni, A.; Kasey, V.; Khaleeq, M.; Leaver, J.; Long, K.; McKigney, E.; Matsushita, T.; Pasternak, J.; Sashalmi, T.; Savidge, T.; Takahashi, M.; Blackmore, V.; Carlisle, T.; Cobb, J. H.; Lau, W.; Rayner, M.; Tunnell, C. D.; Witte, H.; Yang, S.; Booth, C. N.; Hodgson, P.; Howlett, L.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.; Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Ellis, M.; Kyberd, P.; Littlefield, M.; Nebrensky, J. J.; Bross, A. D.; Geer, S.; Neuffer, D.; Moretti, A.; Popovic, M.; Cummings, M. A. C.; Roberts, T. J.; DeMello, A.; Green, M. A.; Li, D.; Virostek, S.; Zisman, M. S.; Freemire, B.; Hanlet, P.; Huang, D.; Kafka, G.; Kaplan, D. M.; Snopok, P.; Torun, Y.; Blot, S.; Kim, Y. K.; Bravar, U.; Onel, Y.; Cline, D.; Fukui, Y.; Lee, K.; Yang, X.; Rimmer, R. A.; Cremaldi, L. M.; Gregoire, G.; Hart, T. L.; Sanders, D. A.; Summers, D. J.; Coney, L.; Fletcher, R.; Hanson, G. G.; Heidt, C.; Gallardo, J.; Kahn, S.; Kirk, H.; Palmer, R. B.

    2012-05-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

  2. Upgrade of the beam transport lines and the beam-abort system and development of a tune compensator in KEKB

    Science.gov (United States)

    Iida, Naoko; Kikuchi, Mitsuo; Mimashi, Toshihiro; Nakayama, Hisayoshi; Sakamoto, Yutaka; Satoh, Kotaro; Takasaki, Seiji; Tawada, Masafumi

    2013-03-01

    The KEKB collider achieved a maximum peak luminosity of 2.1×1034 cm-2 s-1 and an integrated luminosity of 1 ab-1 in its ten-year operation. Behind these glorious records there have been uncountable improvements in every subsystem. This paper describes the improvements in the beam transport line, injection kickers, septum magnets, the beam-abort system, and a newly developed pulsed-quadrupole system in detail.

  3. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Science.gov (United States)

    Braccini, Saverio

    2013-04-01

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few μA for radioisotope production, as well as for both pulsed and continuous beams.

  4. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, Saverio [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2013-04-19

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few {mu}A for radioisotope production, as well as for both pulsed and continuous beams.

  5. Design of the prototype of a beam transport line for handling and selection of low energy laser-driven beams

    Science.gov (United States)

    Schillaci, F.; Maggiore, M.; Cirrone, G. A. P.; Cuttone, G.; Pisciotta, P.; Costa, M.; Rifuggiato, D.; Romano, F.; Scuderi, V.

    2016-11-01

    A first prototype of transport beam-line for laser-driven ion beams to be used for the handling of particles accelerated by high-power laser interacting with solid targets has been realized at INFN. The goal is the production of a controlled and stable beam in terms of energy and angular spread. The beam-line consists of two elements: an Energy Selection System (ESS), already realized and characterized with both conventional and laser-accelerated beams, and a Permanent Magnet Quadrupole system (PMQ) designed, in collaboration with SIGMAPHI (Fr), to improve the ESS performances. In this work a description of the ESS system and some results of its characterization with conventional beams are reported, in order to provide a complete explanation of the acceptance calculation. Then, the matching with the PMQ system is presented and, finally, the results of preliminary simulations with a realistic laser-driven energy spectrum are discussed demonstrating the possibility to provide a good quality beam downstream the systems.

  6. In-line E-beam metrology and defect inspection: industry reflections, hybrid E-beam opportunities, recommendations and predictions

    Science.gov (United States)

    Solecky, Eric; Rasafar, Allen; Cantone, Jason; Bunday, Benjamin; Vaid, Alok; Patterson, Oliver; Stamper, Andrew; Wu, Kevin; Buengener, Ralf; Weng, Weihao; Dai, Xintuo

    2017-03-01

    At SPIE 2013 in Metrology, Inspection, and Process Control for Microlithography an invited paper was published titled "In-line E-beam wafer metrology and defect inspection: the end of an era for image-based critical dimensional metrology? New life for defect inspection". Three years have passed and numerous developments have occurred as predicted in this paper. The development of E-beam tools that can concurrently handle metrology and defect applications is one of the primary developments. In this paper, the capabilities of these new E-beam tools and their current use cases will be discussed in the areas of Critical Dimension Uniformity (CDU), In-die overlay, Hot spot and Physical defect inspection. Emphasis will be placed on use cases where "massive" CDU data is collected in order to increase yield learning for manufacturing (14nm) and decrease cycles of learning for development (7nm). Additionally, some of the other subject material from the previous publication will also be discussed such as the current state of E-beam critical dimension image fidelity and physical defect detection capabilities. Lastly, future directions and opportunities for In-line E-beam including Multi-beam and/or Multi-column E-beam will be discussed.

  7. Visualization and on line monitoring of geometric parameters of beams at KSRS

    CERN Document Server

    Ioudin, L; Potlovsky, K; Rezvov, V

    2001-01-01

    On the basis of developed hardware and software we investigate the opportunity of on line registration of geometric parameters of low intensity SR beam and electron beams in single shot mode. Ionization and luminescence detectors form real optic image of a beam cross section. The image is registered by a TV camera, digitized and processed by a computer. Gray scale image and profiles of a beam are represented. Accumulation and statistic processing of the data give the possibility to increase the sensitivity of the hardware and to calculate the average position of the beam gravity center, dispersion and statistic uncertainty.

  8. A Monitor and Control System for the Synchrotron Radiation Beam Lines at DAΦNE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Three synchrotron radiation beam lines have been built on DAΦNE,the Frascati electron-positron accelerator.It is Possible to monitor and control all the elements on the beam lines using a modular network distributed I/O system by National Instrunments (FieldPoint) with Bridge VIEW/Lab VIEW programs,Two of these beam lines have radiation safety problems solved by two independent and redundant systems,using mechanical switches ,and S7-200 PLC's by Siemens.In this article our solution will be described in details.

  9. Fabrication of patterned mirror modules for generating laser line beams

    Science.gov (United States)

    Lee, Changyun; Kim, Taeggyum; Hong, Sangsu; Kim, Baekyun

    2008-02-01

    A method for fabricating Ag coated beam splitter is reported. This is showing specific patterned transmittance by immersing glass substrates in the mixture of H IISO 4 and H IIO II to make negatively charged oxygen sites at silica surface and then in ethanolic solutions of AgNO 3 and butylamine. We controlled the soaking time and molar ratios of the mixture of AgNO 3 and butylamine to pattern % transmittance of electroless coated glass surface. Finally, we made a functionalized beam splitters showing step function like transmittance and applied this to make multiple laser beams for display and laser machining.

  10. Laser beams as fiducial lines in bubble chambers

    CERN Document Server

    Leutz, H; Klamann, H; Muuss, H; Schmelzer, C

    1971-01-01

    It is proposed to base the fiduciary system of large volume bubble chambers on laser beams originating from theodolite-fixed positions and thus traversing the liquid at well defined space coordinates. From a series of experiments some important conditions for this proposal have been established: Rayleigh-scattering on molecular concentration fluctuations in the chamber liquid is responsible for the visibility of laser beams which can be photographed under angles up to 90 degrees within reasonable exposures. Small-angle random deflections of the laser beam were observed which are due to thermal turbulence in the chamber liquid.

  11. Development of pulsed positron beam line with compact pulsing system

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Masaki, E-mail: maekawa.masaki@jaea.go.jp [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Kawasuso, Atsuo [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2012-01-01

    We have developed a pulsed slow positron beam with a pulse width of less than 200 ps and a period of 25 ns. The beam apparatus is composed of a Munich-type pre-buncher, a chopper and a buncher. Instead of the conventional RF cavity, a simple double-cylinder electrode is used for the buncher. The beam will be used for positron lifetime measurements. The time resolution of the whole system including lifetime measurement circuits is 250 ps, which is adequate for studying semiconductors and metals.

  12. CPT Tests: Kaon vs neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Murayama, Hitoshi

    2003-07-09

    CPT violation has an impressive limit in the neutral kaon system |m(K{sup 0})-m({bar K}{sup 0})| < 10{sup -18} m{sub K} = 0.50 x 10{sup -18} GeV. However, if viewed as a constraint on the mass-squared, the bound appears weak, |m{sup 2}(K{sup 0})-m{sup 2}({bar K}{sup 0})| < 0.25 eV{sup 2}. the authors point out that neutrino oscillation offers better limits on CPT violation in this case. The comparison of solar and rector neutrino results puts the best limit on CPT violation by far, |{Delta}m{sub {nu}}{sup 2}-{Delta}m{sub {rho}}{sup 2}| < 1.3 x 10{sup -3} eV{sup 2} (90% CL).

  13. Nucleon Resonances in Kaon Photoproduction

    CERN Document Server

    Bennhold, C; Waluyo, A; Haberzettl, H; Penner, G; Feuster, T; Mosel, U

    1999-01-01

    Nucleon resonances are investigated through the electromagnetic production of K-mesons. We study the kaon photoproduction process at tree-level and compare to a recently developed unitary K-matrix approach. Employing hadronic form factors along with the proper gauge prescription yields suppression of the Born terms and leads a resonance dominated process for both K-Lambda and K-Sigma photoproduction. Using new SAPHIR data we find the K+-Lambda photoproduction to be dominated by the S11(1650) at threshold, with additional contributions from the P11(1710) and P13(1720) states. The K-Sigma channel couples to a cluster of Delta resonances around W = 1900 MeV. We briefly discuss some tantalizing evidence for a missing D13 resonance around 1900 MeV with a strong branching ratio into KLambda channel.

  14. Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guimei [Peking Univ., Beijing (China)

    2011-12-31

    Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam

  15. One-prong $\\tau$ decays with kaons

    CERN Document Server

    Barate, R.; Ghez, Philippe; Goy, C.; Lees, J.P.; Merle, E.; Minard, M.N.; Pietrzyk, B.; Alemany, R.; Casado, M.P.; Chmeissani, M.; Crespo, J.M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, L.; Grauges, E.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, L.M.; Pacheco, A.; Park, I.C.; Riu, I.; Colaleo, A.; Creanza, D.; De Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Becker, U.; Boix, G.; Cattaneo, M.; Ciulli, V.; Dissertori, G.; Drevermann, H.; Forty, R.W.; Frank, M.; Halley, A.W.; Hansen, J.B.; Harvey, John; Janot, P.; Jost, B.; Lehraus, I.; Leroy, O.; Mato, P.; Minten, A.; Moutoussi, A.; Ranjard, F.; Rolandi, Gigi; Rousseau, D.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Teubert, F.; Tomalin, I.R.; Tournefier, E.; Wright, A.E.; Ajaltouni, Z.; Badaud, F.; Chazelle, G.; Deschamps, O.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.C.; Pallin, D.; Perret, P.; Podlyski, F.; Hansen, J.D.; Hansen, J.R.; Hansen, P.H.; Nilsson, B.S.; Rensch, B.; Waananen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Blondel, A.; Bonneaud, G.; Brient, J.C.; Rouge, A.; Rumpf, M.; Swynghedauw, M.; Verderi, M.; Videau, H.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Cerutti, F.; Chiarella, V.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G.P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Lynch, J.G.; Negus, P.; O'Shea, V.; Raine, C.; Teixeira-Dias, P.; Thompson, A.S.; Buchmuller, O.; Dhamotharan, S.; Geweniger, C.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E.E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D.M.; Cameron, W.; Dornan, P.J.; Girone, M.; Goodsir, S.; Martin, E.B.; Marinelli, N.; Sedgbeer, J.K.; Spagnolo, P.; Thomson, Evelyn J.; Williams, M.D.; Ghete, V.M.; Girtler, P.; Kneringer, E.; Kuhn, D.; Rudolph, G.; Betteridge, A.P.; Bowdery, C.K.; Buck, P.G.; Colrain, P.; Crawford, G.; Finch, A.J.; Foster, F.; Hughes, G.; Jones, R.W.L.; Robertson, N.A.; Williams, M.I.; Giehl, I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.G.; van Gemmeren, P.; Wachsmuth, H.; Zeitnitz, C.; Aubert, J.J.; Benchouk, C.; Bonissent, A.; Carr, J.; Coyle, P.; Etienne, F.; Motsch, F.; Payre, P.; Talby, M.; Thulasidas, M.; Aleppo, M.; Antonelli, M.; Ragusa, F.; Berlich, R.; Buescher, Volker; Dietl, H.; Ganis, G.; Huttmann, K.; Lutjens, G.; Mannert, C.; Manner, W.; Moser, H.G.; Schael, S.; Settles, R.; Seywerd, H.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Azzurri, P.; Boucrot, J.; Callot, O.; Chen, S.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.F.; Heusse, P.; Hocker, Andreas; Jacholkowska, A.; Kim, D.W.; Le Diberder, F.; Lefrancois, J.; Lutz, A.M.; Schune, M.H.; Veillet, J.J.; Videau, I.; Zerwas, D.; Bagliesi, Giuseppe; Bettarini, S.; Boccali, T.; Bozzi, C.; Calderini, G.; Dell'Orso, R.; Ferrante, I.; Foa, L.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P.S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Sciaba, A.; Sguazzoni, G.; Tenchini, R.; Vannini, C.; Venturi, A.; Verdini, P.G.; Blair, G.A.; Cowan, G.; Green, M.G.; Medcalf, T.; Strong, J.A.; von Wimmersperg-Toeller, J.H.; Botterill, D.R.; Clifft, R.W.; Edgecock, T.R.; Norton, P.R.; Thompson, J.C.; Bloch-Devaux, Brigitte; Colas, P.; Emery, S.; Kozanecki, W.; Lancon, E.; Lemaire, M.C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.F.; Roussarie, A.; Schuller, J.P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S.N.; Dann, J.H.; Johnson, R.P.; Kim, H.Y.; Konstantinidis, N.; Litke, A.M.; McNeil, M.A.; Taylor, G.; Booth, C.N.; Cartwright, S.; Combley, F.; Kelly, M.S.; Lehto, M.; Thompson, L.F.; Affholderbach, K.; Boehrer, Armin; Brandt, S.; Grupen, C.; Prange, G.; Giannini, G.; Gobbo, B.; Rothberg, J.; Wasserbaech, S.; Armstrong, S.R.; Charles, E.; Elmer, P.; Ferguson, D.P.S.; Gao, Y.; Gonzalez, S.; Greening, T.C.; Hayes, O.J.; Hu, H.; Jin, S.; McNamara, P.A., III; Nachtman, J.M.; Nielsen, J.; Orejudos, W.; Pan, Y.B.; Saadi, Y.; Scott, I.J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Zobernig, G.

    1999-01-01

    One-prong $\\tau$ decays into final states involving kaons are studied with about 161k $\\tau^+\\tau^-$ events collected by the ALEPH detector from 1991 to 1995. Charged kaons are identified by dE/dx measurement, while $K^0_L$'s are detected through their interaction in calorimeters. Branching ratios are measured for the inclusive mode, $B(\\tau^-\\rightarrow K^-X\

  16. A straw drift chamber spectrometer for studies of rare kaon decays

    CERN Document Server

    Lang, K; Arroyo, C; Bachman, M; Connor, D; Eckhause, M; Ecklund, K M; Graessle, S C; Hamela, M; Hamilton, S; Hancock, A D; Hartman, K; Hebert, M; Hoff, C H; Hoffmann, G W; Irwin, G M; Kane, J R; Kanematsu, N; Kuang, Y; Lee, R; Marcin, M; Martin, R D; McDonough, J; Milder, A J; Molzon, W R; Ouimette, D A; Pommot-Maia, M C; Proga, M; Riley, P J; Ritchie, J L; Rubin, P D; Vassilakopoulos, V I; Ware, B; Welsh, R E; Wojcicki, S G; Worm, S

    2004-01-01

    We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds.

  17. Transverse target single-spin asymmetry in inclusive electroproduction of charged pions and kaons

    OpenAIRE

    Airapetian, Avetik; Akopov, N.; Blok, H. P.; Schnell, Gunar; Seitz, B.; Shibata, T.A.; Shutov, V.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stewart, J.; Stinzing, F.; Borissov, A.; Taroian, S.

    2014-01-01

    Single-spin asymmetries were investigated in inclusive electroproduction of charged pions and kaons from transversely polarized protons at the HERMES experiment. The asymmetries were studied as a function of the azimuthal angle $\\psi$ about the beam direction between the target-spin direction and the hadron production plane, the transverse hadron momentum relative to the direction of the incident beam, and the Feynman variable $x_F$. The $\\sin(\\psi)$ amplitudes are positive for positive pions...

  18. Transverse target single-spin asymmetry in inclusive electroproduction of charged pions and kaons

    OpenAIRE

    Airapetian, A.; Akopov, N.; Blok, H. P.; Schnell, G.; Seitz, B.; Shibata, T.A.; Shutov, V.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stewart, J.; Stinzing, F.; Borissov, A.; Taroian, S.

    2013-01-01

    Single-spin asymmetries were investigated in inclusive electroproduction of charged pions and kaons from transversely polarized protons at the HERMES experiment. The asymmetries were studied as a function of the azimuthal angle $\\psi$ about the beam direction between the target-spin direction and the hadron production plane, the transverse hadron momentum relative to the direction of the incident beam, and the Feynman variable $x_F$. The $\\sin(\\psi)$ amplitudes are positive for positive pions...

  19. A straw drift chamber spectrometer for studies of rare kaon decays

    Energy Technology Data Exchange (ETDEWEB)

    Lang, K. E-mail: lang@mail.hep.utexas.edu; Ambrose, D.; Arroyo, C.; Bachman, M.; Connor, D.; Eckhause, M.; Ecklund, K.M.; Graessle, S.; Hamela, M.; Hamilton, S.; Hancock, A.D.; Hartman, K.; Hebert, M.; Hoff, C.H.; Hoffmann, G.W.; Irwin, G.M.; Kane, J.R.; Kanematsu, N.; Kuang, Y.; Lee, R.; Marcin, M.; Martin, R.D.; McDonough, J.; Milder, A.; Molzon, W.R.; Ouimette, D.; Pommot-Maia, M.; Proga, M.; Riley, P.J.; Ritchie, J.L.; Rubin, P.D.; Vassilakopoulos, V.I.; Ware, B.; Welsh, R.E.; Wojcicki, S.G.; Worm, S

    2004-04-21

    We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5-mm-diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds.

  20. Transport and dosimetric solutions for the ELIMED laser-driven beam line

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Romano, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Scuderi, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Amato, A. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Candiano, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Cuttone, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Giove, D. [INFN Sezione di Milano, Via Celoria 16, Milano (Italy); Korn, G.; Krasa, J. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Leanza, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Manna, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Maggiore, M. [INFN-LNL, Viale dell' Universitá 2 - 35020 Legnaro (PD) (Italy); Marchese, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Margarone, D. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Milluzzo, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Petringa, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Sabini, M.G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Azienda Ospedaliera Cannizzaro, Via Messina 829 - 95100 Catania (Italy); Schillaci, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); and others

    2015-10-01

    Within 2017, the ELIMED (ELI-Beamlines MEDical applications) transport beam-line and dosimetric systems for laser-generated beams will be installed at the ELI-Beamlines facility in Prague (CZ), inside the ELIMAIA (ELI Multidisciplinary Applications of laser–Ion Acceleration) interaction room. The beam-line will be composed of two sections: one in vacuum, devoted to the collecting, focusing and energy selection of the primary beam and the second in air, where the ELIMED beam-line dosimetric devices will be located. This paper briefly describes the transport solutions that will be adopted together with the main dosimetric approaches. In particular, the description of an innovative Faraday Cup detector with its preliminary experimental tests will be reported.

  1. Kaons in nuclear matter; Kaonen in Kernmaterie

    Energy Technology Data Exchange (ETDEWEB)

    Kolomeitsev, E.E.

    1997-02-01

    The subject of the doctoral thesis is examination of the properties of kaons in nuclear matter. A specific method is explained that has been developed for the scientific objectives of the thesis and permits description of the kaon-nucleon interactions and kaon-nucleon scattering in a vacuum. The main challenge involved was to find approaches that would enable application of the derived relations out of the kaon mass shell, connected with the second objective, namely to possibly find methods which are independent of models. The way chosen to achieve this goal relied on application of reduction formulas as well as current algebra relations and the PCAC hypothesis. (orig./CB) [Deutsch] Die Arbeit befasst sich mit der Untersuchung der Eigenschaften von Kao nen in Kernmaterie. Zu diesem Zweck wurde ein Verfahren entwickelt, di e Kaon- Nukleon- Wechselwirkung und Kaon- Nukleon- Streuung im Vakuumzu beschreiben. Die Hauptherausforderung bestand darin, dass die abgel eiteten Relationen ausserhalb der Kaonen- Massenschale anwendbar werde n. Eine Nebenforderung war, dass die vorgeschlagenen Verfahren moeglic hst modell- unabhaengig sind. Um dieses Ziel zu erreichen, wurden Redu ktionsformeln, Stromalgebra- Relationen und die PCAC- Hypothese angewe ndet.

  2. Measurement of Velocity Distribution in Atomic Beam by Diode Laser with Narrow Line width

    Institute of Scientific and Technical Information of China (English)

    CHEN Jingbiao; WANG Fengzhi; YANG Donghai; WANG YiQiu

    2001-01-01

    In this paper, by using the detecting laser beam interacts with the atomic beam at a sharp angle and the Doppler frequency shift effect, the velocity distribution in cesium atomic beam is measured with a diode laser of narrow linewidth of 1 MHz. The effects of the atomic natural line width and cycling transition detecting factor on the measured results have been analyzed. Finally, the measured results have been compared with the theoretical calculation.

  3. A transition radiation detector for kaon/pion separation

    Energy Technology Data Exchange (ETDEWEB)

    Baake, M.; Diekmann, B.; Gebert, F.; Heinloth, K.; Holzkamp, S.; Koersgen, G.; Voigtlaender-Tetzner, A. (Bonn Univ. (Germany, F.R.)); Bagdassarian, L.; Kazarian, C.; Oganessian, A. (Erevanskij Gosudarstvennyj Univ. (USSR))

    1989-09-01

    The experiment WA69 at the CERN Omega spectrometer facility has studied fixed target photon and hadron production of inclusive hadronic final states with tagged photon beams of 65-175 GeV in comparison to charged hadron beams ({pi} and K) of 80 and 140 GeV fixed energies. For the identification of final state pions and kaons above 100 GeV/c a transition radiation detector (TRAD) has been developed. This detector was constructed of 12 modules, each consisting of a polypropylene fibre radiator and a proportional chamber with a xenon/methane gas mixture to detect the transition radiation produced by fast moving charged particles. We give a description of the detector setup and working conditions. As a first result obtained with the TRAD the ratio of photoproduced kaons and pions in the extreme forward regime (x{sub F}>0.7 and -t<1 GeV{sup 2}) is measured to be 10.2(+-1.7)% which is in agreement with VDM predictions. (orig.).

  4. BEAM EXTRACTION FROM THE RECYCLER RING TO P1 LINE AT FERMILAB

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, M. [Fermilab; Capista, D. [Fermilab; Adams, P. [Fermilab; Morris, D. [Fermilab; Yang, M. J. [Fermilab; Hazewood, K. [Fermilab

    2016-10-03

    The transfer line for beam extraction from the Recycler ring to P1 line provides a way to deliver 8 GeV kinetic energy protons from the Booster to the Delivery ring, via the Recycler, using existing beam transport lines, and without the need for new civil construction. It was designed in 2012. The kicker magnets at RR520 and the lambertson magnet at RR522 in the RR were installed in 2014 Summer Shutdown, the elements of RR to P1 Stub (permanent quads, trim quads, correctors, BPMs, the toroid at 703 and vertical bending dipole at V703 (ADCW) were installed in 2015 Summer Shutdown. On Tuesday, June 21, 2016, beam line from the Recycler Ring to P1 line was commissioned. The detailed results will be presented in this report.

  5. Interleaving of beam lines inside the PS tunnel

    CERN Multimedia

    1983-01-01

    View against the direction of the proton beams. The PS ring (section 26) is on the left. The injection tunnel for LEAR leaving from here has increased the trafic in this already busy area where the two Linacs and the transfer tunnel leading to the SPS, ISR and AA join the PS ring (cf. photo 7802260, 7802261, Annual Report 1981, p. 89, fig. 12).

  6. Status of the PXIE Low Energy Beam Transport Line

    Energy Technology Data Exchange (ETDEWEB)

    Prost, Lionel [Fermilab; Andrews, Richard [Fermilab; Chen, Alex [Fermilab; Hanna, Bruce [Fermilab; Scarpine, Victor [Fermilab; Shemyakin, Alexander [Fermilab; Steimel, Jim [Fermilab; D' Arcy, Richard [University Coll. London

    2014-07-01

    A CW-compatible, pulsed H- superconducting RF linac (a.k.a. PIP-II) is envisaged as a possible path for upgrading Fermilab’s injection complex [1]. To validate the concept of the front-end of such machine, a test accelerator (a.k.a. PXIE) [2] is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2m-long LEBT, a 2.1 MeV CW RFQ, and a MEBT that feeds the first cryomodule. In addition to operating in the nominal CW mode, the LEBT should be able to produce a pulsed beam for both PXIE commissioning and modelling of the front-end nominal operation in the pulsed mode. Concurrently, it needs to provide effective means of inhibiting beam as part of the overall machine protection system. A peculiar feature of the present LEBT design is the capability of using the ~1m-long section immediately preceding the RFQ in two regimes of beam transport dynamics: neutralized and space charge dominated. This paper introduces the PXIE LEBT, reports on the status of the ion source and LEBT installation, and presents the first beam measurements.

  7. Design of the low energy beam transport line for the China spallation neutron source

    Institute of Scientific and Technical Information of China (English)

    LI Jin-Hai; OUYANG Hua-Fu; FU Shi-Nian; ZHANG Sua-Shun; HE Wei

    2008-01-01

    The design of the China Spallation Neutron Source (CSNS) low-energy beam transport (LEBT) line, which locates between the ion source and the radio-frequency quadrupole (RFQ), has been completed with the TRACE3D code. The design aims at perfect matching, primary chopping, a small emittance growth and sufficient space for beam diagnostics. The line consists of three solenoids, three vacuum chambers, two steering magnets and a pre-chopper. The total length of LEBT is about 1.74 m. This LEBT is designed to transfer 20 mA of H-pulsed beam from the ion source to the RFQ. An induction cavity is adopted as the pre-chopper.The electrostatic octupole steerer is discussed as a candidate. A four-quadrant aperture for beam scraping and beam position monitoring is designed.

  8. Emittance Measurements For Future LHC Beams Using The PS Booster Measurement Line

    CERN Document Server

    Abelleira, Jose; Mikulec, Bettina; Di Giovanni, Gian Piero; CERN. Geneva. ATS Department

    2017-01-01

    The CERN PS Booster measurement line contains three pairs of SEM grids separated by drift space that measures the beam size in both planes. The combined analysis of these grids allows calculating a value for the transverse beam emittances. The precision of such a measurement depends on the ratio of RMS beam size and wire spacing. Within the LIU-PSB upgrade the extraction kinetic energy of the PSB will be increased from the current 1.4 GeV to 2.0 GeV. This will result in smaller transverse beam sizes for some of the future beams. The present layout of the transverse emittance measurement line is reviewed to verify if it will satisfy future requirements.

  9. Status of the ELIMED multidisciplinary and medical beam-line at ELI-Beamlines

    Science.gov (United States)

    Romano, F.; Cirrone, G. A. P.; Cuttone, G.; Schillaci, F.; Scuderi, V.; Amico, A.; Candiano, G.; Giordanengo, S.; Guarachi, L. F.; Korn, G.; Larosa, G.; Leanza, R.; Manna, R.; Marchese, V.; Marchetto, F.; Margarone, D.; Milluzzo, G.; Petringa, G.; Pipek, J.; Sacchi, R.; Vignati, A.

    2017-01-01

    Nowadays, one of the biggest challenges consists in using high intensity laser-target interaction to generate high-energy ions for medical purposes, eventually replacing the old paradigm of acceleration characterized by huge and complex machines. In order to investigate the feasibility of using laser-driven ion beams for multidisciplinary application, a dedicated beam transport line will be installed at the ELI-Beamlines facility in Prague (CZ), as a part of the User-oriented ELIMAIA beam-line dedicated to ion acceleration and their potential applications. The beam-line section dedicated to transport and dosimetric endpoints is called ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) and will be developed by the INFN-LNS.

  10. Magnet Design for the ISIS Second Target Station Proton Beam Line

    CERN Document Server

    Thomas, Chris; Jago, Stephen

    2005-01-01

    The ISIS facility, based at the Rutherford Appleton Laboratory in the UK, is an intense source of neutrons and muons for condensed matter research. The accelerator facility delivers an 800 MeV proton beam of 2.5x1013 protons per pulse at 50 Hz to the present target station. As part of a facility upgrade, it is planned to share the source with a second, 10 Hz, target station. The beam line supplying this target will extract from the existing target station beam line. Electromagnetic Finite Element Modelling techniques have been used to design the magnets required to meet the specified beam line optics. Kicker, septum, dipole, quadrupole, and steering magnets are covered. The magnet design process, involving 2D and 3D modelling, the calculation of ideal shims and chamfers, choice of steel, design of conducting coils, handling of heating issues and eddy current effects, is discussed.

  11. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    CERN Document Server

    Gencer, A.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-01-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between View the MathML source10μA and View the MathML source1.2mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam ...

  12. X International Conference on Kaon Physics

    Science.gov (United States)

    2017-01-01

    The International Conference on Kaon Physics 2016 took place at the University of Birmingham (United Kingdom) on 14-17 September 2016. This conference continued the KAON series, offering an opportunity for theorists and experimentalists from the high-energy physics community to discuss all aspects of kaon physics. The 2016 edition saw a strong participation from theory and phenomenology and the first kaon results from the LHCb experiment at CERN, as well as updates from several experiments around the world including NA62 and KOTO. All papers published in this volume of KAON2016 have been peer reviewed through processes administered by the proceedings Editors. Reviews were conducted by expert referees to the professional and scientific standards expected of a proceedings journal published by IOP Publishing. The organizers and the participants wish to thank the University of Birmingham, the European Research Council, CERN, the UK Science and Technology Facility Council and the UK Institute for Particle Physics Phenomenology for their support in the organization of this successful edition. Figure for summary

  13. Exploring Hadron Structure Through Exclusive Kaon Electroproduction

    Energy Technology Data Exchange (ETDEWEB)

    Carmignotto, Marco A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-04-01

    The kaon electroproduction cross section was extracted from data from the E93-018 and the E01-004 (FPI-2) experiments taken at the Thomas Jefferson National Accelerator Facility in the p(e,e'K+)Λ channel. The cross section was fully separated into longitudinal, transverse, and two interference components at four-momentum transfers Q2 of 1.0 (GeV/c)2 (with center of mass energy W=1.81 GeV), 1.36 and 2.07 (GeV/c)2 (W=2.31 GeV). The kaon form factor (FK) was extracted from the longitudinal cross section in these kinematics using the Regge model by Vanderhaeghen, Guidal, and Laget. Results show FK to be systematically lower than the empirical monopole form, although still compatible with this form within the estimated uncertainties. The resulting kaon form factor values were combined with the world pion and kaon form factor data to extract the transverse change densities of the pion and kaon. These were compared to that of the proton, showing a possible experimental glimpse of the transition between the proton core and the meson cloud in terms of transverse densities.

  14. Revisiting RG Flow for Kaon Condensation

    CERN Document Server

    Paeng, Won-Gi

    2014-01-01

    Kaon condensation in compact-star matter can be considered as a quantum critical phenomenon with the kaon mass tuned to zero by the baryon density plus the electron chemical potential that increases at the increase of the density. We approach this problem with a renormalization group flow at one loop of the system of anti-kaons considered as pseudo-Goldstone bosons coupled to nucleonic matter described as a Fermi liquid near its fixed point. While the Weinberg-Tomozawa term in chiral Lagrangians is of leading order in describing kaon-nucleon interactions in chiral perturbation theory, hence widely employed in the literature, it is irrelevant in the RG sense, therefore plays, if any, a less important role in the condensation process. The consequence is that the $\\Lambda (1405)$ resonance which is driven by the Weinberg-Tomozawa term is irrelevant for triggering kaon condensation. On the contrary, the $KN$ sigma term $\\Sigma_{KN}$, subleading in chiral counting, can play a more crucial role in renormalization g...

  15. Transverse Flow of Kaons in Heavy-Ion Collisions

    Institute of Scientific and Technical Information of China (English)

    郑玉明; 储自力; FUCHS Christian; FAESSLER Amand; 肖武; 华大平; 阎玉鹏

    2002-01-01

    The transverse flow of positively charged kaons from heavy-ion collisions at intermediate energy is investigatedwithin the framework of the quantum molecular dynamics model. The calculated results show that the experi-mental data are only consistent with those including the kaon mean-field potential from the chiral Lagrangian.This indicates that the transverse flow pattern of kaons is a useful probe of the kaon potential in a nuclearmedium.

  16. The Joint Structural Biology Group beam lines at the ESRF: Modern macromolecular crystallography

    CERN Document Server

    Mitchell, E P

    2001-01-01

    Macromolecular crystallography has evolved considerably over the last decade. Data sets in under an hour are now possible on high throughput beam lines leading to electron density and, possibly, initial models calculated on-site. There are five beam lines currently dedicated to macromolecular crystallography: the ID14 complex and BM-14 (soon to be superseded by ID-29). These lines handle over five hundred projects every six months and demand is increasing. Automated sample handling, alignment and data management protocols will be required to work efficiently with this demanding load. Projects developing these themes are underway within the JSBG.

  17. Chemical investigations of isotope separation on line target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive ion beams (RIBs) are of significant interest in a number of applications. Isotope separation on line (ISOL) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to CO/sub x/ and NOmaterials are potential construction materials for the above-mentioned areas. Off-line and on-line tests have been performed using a gas thermochromatography setup with radioactive tracers. The experiments were performed at the production of tracers for atmospheric chemistry (PROTRAC) facility at the Paul Schener Institute in Villigen...

  18. Changes to the Transfer Line Collimation System for the High-Luminosity LHC Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V. [CERN; Aberle, O. [CERN; Bracco, C. [CERN; Fraser, M. [CERN; Galleazzi, F. [CERN; Gianfelice-Wendt, E. [Fermilab; Kosmicki, A. [CERN; Maciariello, F. [CERN; Meddahi, M. [CERN; Nuiry, F. X. [CERN; Steele, G. [CERN; Velotti, F. [CERN

    2015-06-01

    The current LHC transfer line collimation system will not be able to provide enough protection for the high brightness beams in the high-luminosity LHC era. The new collimation system will have to attenuate more and be more robust than its predecessor. The active jaw length of the new transfer line collimators will therefore be 2.1 m instead of currently 1.2 m. The transfer line optics will have to be adjusted for the new collimator locations and larger beta functions at the collimators for absorber robustness reasons. In this paper the new design of the transfer line collimation system will be presented with its implications on transfer line optics and powering, maintainability, protection of transfer line magnets in case of beam loss on a collimator and protection of the LHC aperture.

  19. Changes to the Transfer Line Collimation System for the High-Luminosity LHC Beams

    CERN Document Server

    Kain, V; Bracco, C; Fraser, M; Galleazzi, F; Gianfelice-Wendt, E; Kosmicki, A; Maciariello, F; Meddahi, M; Nuiry, F X; Steele, G; Velotti, F

    2015-01-01

    The current LHC transfer line collimation system will not be able to provide enough protection for the high brightness beams in the high-luminosity LHC era. The new collimation system will have to attenuate more and be more robust than its predecessor. The active jaw length of the new transfer line collimators will therefore be 2.1 m instead of currently 1.2 m. The transfer line optics will have to be adjusted for the new collimator locations and larger beta functions at the collimators for absorber robustness reasons. In this paper the new design of the transfer line collimation system will be presented with its implications on transfer line optics and powering, maintainability, protection of transfer line magnets in case of beam loss on a collimator and protection of the LHC aperture.

  20. Induced polarization of {\\Lambda}(1116) in kaon electroproduction

    CERN Document Server

    Gabrielyan, M; Carman, D S; Park, K; Adhikari, K P; Adikaram, D; Amaryan, M J; Pereira, S Anefalos; Avakian, H; Ball, J; Baltzell, N A; Battaglieri, M; Baturin, V; Bedlinskiy, I; Biselli, A S; Bono, J; Boiarinov, S; Briscoe, W J; Brooks, W K; Burkert, V D; Cao, T; Celentano, A; Chandavar, S; Charles, G; Cole, P L; Contalbrigo, M; Cortes, O; Crede, V; DAngelo, A; Dashyan, N; De Vita, R; De Sanctis, E; Deur, A; Djalali, C; Doughty, D; Dupre, R; Fassi, L El; Eugenio, P; Fedotov, G; Fegan, S; Fleming, J A; Forest, T A; Garillon, B; Gevorgyan, N; Ghandilyan, Y; Gilfoyle, G P; Giovanetti, K L; Girod, F X; Goetz, J T; Golovatch, E; Gothe, R W; Griffioen, K A; Guidal, M; Guo, L; Hafidi, K; Hakobyan, H; Hattawy, M; Hicks, K; Ho, D; Holtrop, M; Hughes, S M; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Jenkins, D; Jiang, H; Jo, H S; Joo, K; Keller, D; Khandaker, M; Kim, W; Klein, F J; Koirala, S; Kubarovsky, V; Kuhn, S E; Kuleshov, S V; Lenisa, P; Levine, W I; Livingston, K; MacGregor, I J D; Mayer, M; McKinnon, B; Meyer, C A; Mestayer, M D; Mirazita, M; Mokeev, V; Moody, C I; Moutarde, H; Movsisyan, A; Munevar, E; Camacho, C Munoz; Nadel-Turonski, P; Niccolai, S; Niculescu, G; Osipenko, M; Pappalardo, L L; Paremuzyan, R; Pasyuk, E; Peng, P; Phelps, W; Phillips, J J; Pisano, S; Pogorelko, O; Pozdniakov, S; Price, J W; Procureur, S; Protopopescu, D; Rimal, D; Ripani, M; Rizzo, A; Sabatie, F; Salgado, C; Schott, D; Schumacher, R A; Simonyan, A; Smith, G D; Sober, D I; Sokhan, D; Stepanyan, S S; Stepanyan, S; Strakovsky, I I; Strauch, S; Sytnik, V; Tang, W; Ungaro, M; Vlassov, A V; Voskanyan, H; Voutier, E; Walford, N K; Watts, D P; Wei, X; Weinstein, L B; Zachariou, N; Zana, L; Zhang, J

    2014-01-01

    We have measured the induced polarization of the ${\\Lambda}(1116)$ in the reaction $ep\\rightarrow e'K^+{\\Lambda}$, detecting the scattered $e'$ and $K^+$ in the final state along with the proton from the decay $\\Lambda\\rightarrow p\\pi^-$.The present study used the CEBAF Large Acceptance Spectrometer (CLAS), which allowed for a large kinematic acceptance in invariant energy $W$ ($1.6\\leq W \\leq 2.7$ GeV) and covered the full range of the kaon production angle at an average momentum transfer $Q^2=1.90$ GeV$^2$.In this experiment a 5.50 GeV electron beam was incident upon an unpolarized liquid-hydrogen target. We have mapped out the $W$ and kaon production angle dependencies of the induced polarization and found striking differences from photoproduction data over most of the kinematic range studied. However, we also found that the induced polarization is essentially $Q^2$ independent in our kinematic domain, suggesting that somewhere below the $Q^2$ covered here there must be a strong $Q^2$ dependence. Along wit...

  1. The Challenge of Interfacing the Primary Beam Lines for the AWAKE Project at CERN

    CERN Document Server

    Bracco, C; Gschwendtner, E; Meddahi, M; Petrenko, A; Velotti, FM

    2014-01-01

    The Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) at CERN foresees the simultaneous operation of a proton, a laser and an electron beam. The first stage of the experiment will consist in proving the self-modulation, in the plasma, of a long proton bunch into micro-bunches. The success of this experiment requires an almost perfect concentricity of the proton and laser beam, over the full length of the plasma cell. The complexity of integrating the laser into the proton beam line and fulfilling the strict requirements in terms of pointing precision of the proton beam at the plasma cell are described. The second stage of the experiment foresees also the injection of electron bunches to probe the accelerating wakefields driven by the proton beam. Studies were performed to evaluate the possibility of injecting the electron beam parallel and with an offset to the beam axis. This option would imply that protons and electrons will have to share the last few meters of a common beam line. Issues and po...

  2. CP Violation in Kaon Decays (II)

    CERN Document Server

    Yamanaka, Taku

    2014-01-01

    Major progress has been made in kaon physics in the past 50 years. The number of KL->pi+pi- events has increased by 6 orders of magnitude, and the observed CP violation was experimentally proven to be caused by a complex phase in the CKM matrix. Recent kaon experiments are now searching for new physics beyond the standard model with the K->pi nu nu-bar decays. The branching ratio of K->pi nu nu-bar decays are 7-8 orders of magnitude smaller than the branching ratio of KL->pi+ pi-. This paper reviews the progress of kaon experiments in the US and Japan, and how the 6-7 orders of magnitude improvements were possible in the past 50 years.

  3. Proposal for a Multi-Use Test Beam Area in the SLAC B-Line

    CERN Document Server

    Emma, Paul; Erickson, Roger; Fieguth, Theodore; Seeman, John; Seryi, Andrei

    2005-01-01

    With the impending construction of the Linac Coherent Light Source (LCLS) at SLAC, displacing the well-used Final Focus Test Beam (FFTB) area, there is growing interest in developing a new test beam facility, available during LCLS operations and located in the old B-Line tunnel at the end of the linac. The success of the Sub-Picosecond Pulse Source (SPPS) and the desire to preserve this capacity suggests a new beamline with similar or improved electron beam quality, including bunch length compression to 10 microns. Beam availability during LCLS operations requires a new 1.2-km bypass line connecting the 2/3-point of the linac with the B-Line. A second operating mode, with LCLS not in use, involves a trajectory directly from the end of the linac to the B-line. This feature provides the highest beam quality at 30 GeV, and also allows a possible third operational mode by deflecting a few of the very high-brightness 120-Hz, 14-GeV LCLS bunches at low rate (1-10 Hz) into the B-line. Finally, linear collider resear...

  4. Modification and alignment of beam line of 10 MeV RF electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Barnwal, R; Ghodke, S R; Bhattacharjee, D; Kumar, M; Jayaprakash, D; Chindarkar, A R; Mishra, R L; Kumar, M; P, Dixit K; S, Acharya; Barje, S R; Lawangare, N K; C, Saroj P; Nimje, V T; Chandan, S; Tillu, A R; V, Sharma; Chavan, R B [Accelerator and Pulse Power Division, BARC, Mumbai, India-400085 (India); Dolas, S [Centre for Design and Manufacturing, BARC, Mumbai, India-400085 (India); Kulkarni, S Y [SAMEER, IIT Powai campus, Mumbai, India-400076 (India)], E-mail: rajesh_barc47@indiatimes.com (and others)

    2008-05-01

    A 10 MeV, 10 kW RF industrial Electron linac designed and developed at BARC is installed at the Electron Beam Center Kharghar, Navi Mumbai. The entire RF accelerator assembly consists of Electron gun, RF source, RF linac structure, Beam diagnostic chamber, Drift tube, Scanning magnet, Beam sensing aperture, Scan horn, and is spread over two floors at EBC. The paper discusses in detail about the alignment procedure adopted for the equipments of 10 MeV RF beamline. The complete electron beamline will be maintained under ultra high vacuum of the order of 10-7 torr. The paper discusses about the present problem of alignment, measurement technique of alignment, reason for misalignment, possible ways to solve the problem, equipment used for alignment, supports and arrestors, verification of alignment under vacuum.

  5. Modification & alignment of beam line of 10 MeV RF electron beam accelerator

    Science.gov (United States)

    Barnwal, R.; Ghodke, S. R.; Bhattacharjee, D.; Kumar, M.; Jayaprakash, D.; Chindarkar, A. R.; Mishra, R. L.; Dolas, S.; Kulkarni, S. Y.; Kumar, M.; P, Dixit K.; S, Acharya; Barje, S. R.; Lawangare, N. K.; C, Saroj P.; Nimje, V. T.; Chandan, S.; Tillu, A. R.; V, Sharma; Chavan, R. B.; V, Yadav; P, Roychowdhury; Mittal, K. C.; Chakravarthy, D. P.; Ray, A. K.

    2008-05-01

    A 10 MeV, 10 kW RF industrial Electron linac designed and developed at BARC is installed at the Electron Beam Center Kharghar, Navi Mumbai. The entire RF accelerator assembly consists of Electron gun, RF source, RF linac structure, Beam diagnostic chamber, Drift tube, Scanning magnet, Beam sensing aperture, Scan horn, and is spread over two floors at EBC. The paper discusses in detail about the alignment procedure adopted for the equipments of 10 MeV RF beamline. The complete electron beamline will be maintained under ultra high vacuum of the order of 10-7 torr. The paper discusses about the present problem of alignment, measurement technique of alignment, reason for misalignment, possible ways to solve the problem, equipment used for alignment, supports & arrestors, verification of alignment under vacuum

  6. Kaons in flavour tagged B decays

    Science.gov (United States)

    Albrecht, H.; Ehrlichmann, H.; Hamacher, T.; Hofmann, R. P.; Kirchhoff, T.; Nau, A.; Nowak, S.; Schröder, H.; Schulz, H. D.; Walter, M.; Wurth, R.; Hast, C.; Kolanoski, H.; Kosche, A.; Lange, A.; Lindner, A.; Mankel, R.; Schieber, M.; Siegmund, T.; Spaan, B.; Thurn, H.; Töpfer, D.; Wegener, D.; Bittner, M.; Eckstein, P.; Paulini, M. G.; Reim, K.; Wegener, H.; Mundt, R.; Oest, T.; Reiner, R.; Schmidt-Parzefall, W.; Funk, W.; Stiewe, J.; Werner, S.; Ehret, K.; Hofmann, W.; Hüpper, A.; Khan, S.; Knöpfle, K. T.; Seeger, M.; Spengler, J.; Britton, D. I.; Charlesworth, C. E. K.; Edwards, K. W.; Hyatt, E. R. F.; Kapitza, H.; Krieger, P.; Macfarlane, D. B.; Patel, P. M.; Prentice, J. D.; Saull, P. R. B.; Tzamariudaki, K.; van de Water, R. G.; Yoon, T.-S.; Reßing, D.; Schmidtler, M.; Schneider, M.; Schubert, K. R.; Strahl, K.; Waldi, R.; Weseler, S.; Kernel, G.; Križan, P.; Križnič, E.; Podobnik, T.; Živko, T.; Cronström, H. I.; Jönsson, L.; Balagura, V.; Belyaev, I.; Chechelnitsky, S.; Danilov, M.; Droutskoy, A.; Gershtein, Yu.; Golutvin, A.; Kostina, G.; Litvintsev, D.; Lubimov, V.; Pakhlov, P.; Ratnikov, F.; Semenov, S.; Snizhko, A.; Soloshenko, V.; Tichomirov, I.; Zaitsev, Yu.

    1994-09-01

    Using the ARGUS detector at the e + e - storage ring DORIS II, flavour-dependent kaon production in B meson decays has been studied. Using the leptons as flavour tags, it has been possible to separately measure the multiplicities of K +, K - and K {/s 0} in inclusive B decays and in semileptonic B decays. The kaon production in semileptonic B decays was further used to estimate the ratio of charmed decays over all decays, and thus also the fraction of charmless B decays.

  7. Rare kaon, muon, and pion decay

    Energy Technology Data Exchange (ETDEWEB)

    Littenberg, L.

    1998-12-01

    The author discusses the status of and prospects for the study of rare decays of kaons, muons, and pions. Studies of rare kaon decays are entering an interesting new phase wherein they can deliver important short-distance information. It should be possible to construct an alternative unitarity triangle to that determined in the B sector, and thus perform a critical check of the Standard Model by comparing the two. Rare muon decays are beginning to constrain supersymmetric models in a significant way, and future experiments should reach sensitivities which this kind of model must show effects, or become far less appealing.

  8. Quark model for kaon nucleon scattering

    Indian Academy of Sciences (India)

    Ahmed Osman

    2011-12-01

    Kaon nucleon elastic scattering is studied using chiral (3) quark model including antiquarks. Parameters of the present model are essentially based on nucleon–nucleon and nucleon–hyperon interactions. The mass of the scalar meson is taken as 635 MeV. Using this model, the phase shifts of the and partial waves of the kaon nucleon elastic scattering are investigated for isospins 0 and 1. The results of the numerical calculations of different partial waves are in good agreement with experimental data.

  9. Pulse-by-pulse multi-beam-line operation for x-ray free-electron lasers

    Directory of Open Access Journals (Sweden)

    Toru Hara

    2016-02-01

    Full Text Available The parallel operation of plural undulator beam lines is an important means of improving the efficiency and usability of x-ray free-electron laser facilities. After the installation of a second undulator beam line (BL2 at SPring-8 Angstrom compact free-electron laser (SACLA, pulse-by-pulse switching between two beam lines was tested using kicker and dc twin-septum magnets. To maintain a compact size, all undulator beam lines at SACLA are designed to be placed within the same undulator hall located downstream of the accelerator. In order to ensure broad tunability of the laser wavelength, the electron bunches are accelerated to different beam energies optimized for the wavelengths of each beam line. In the demonstration, the 30 Hz electron beam was alternately deflected to two beam lines and simultaneous lasing was achieved with 15 Hz at each beam line. Since the electron beam was deflected twice by 3° in a dogleg to BL2, the coherent synchrotron radiation (CSR effects became non-negligible. Currently in a wavelength range of 4–10 keV, a laser pulse energy of 100–150  μJ can be obtained with a reduced peak current of around 1 kA by alleviating the CSR effects. This paper reports the results and operational issues related to the multi-beam-line operation of SACLA.

  10. The Gas Flow from the Gas Attenuator to the Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.D.

    2010-12-03

    The gas leak from the gas attenuator to the main beam line of the Linac Coherent Light Source has been evaluated, with the effect of the Knudsen molecular beam included. It has been found that the gas leak from the gas attenuator of the present design, with nitrogen as a working gas, does not exceed 10{sup -5} torr x l/s even at the highest pressure in the main attenuation cell (20 torr).

  11. On-Line Bunch Tomography and Beam Modelling for MTE Commissioning

    CERN Document Server

    Rothe, Johannes

    2015-01-01

    For my stay as a CERN Summer Student from June 29 to September 25, 2015, I worked with Guido Sterbini of the Accelerator and Beam Physics group. I was based in the CERN Control Center (CCC) at the Prevessin Site, and supported the ongoing beam commissioning work on Multi-Turn Extraction through the development of on-line monitoring and control tools for the Proton Synchrotron (PS) machine.

  12. Evaluation and Compensation of Detector Solenoid Effects on Disrupted Beam in the ILC 14 mrad Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Toprek, Dragan; /VINCA Inst. Nucl. Sci., Belgrade; Nosochkov, Yuri; /SLAC

    2008-12-18

    This paper presents calculations of detector solenoid effects on disrupted primary beam in the ILC 14 mrad extraction line. Particle tracking simulations are performed for evaluation of primary beam loss along the line as well as of beam distribution and polarization at Compton Interaction Point. The calculations are done both without and with solenoid compensation. The results are obtained for the baseline ILC energy of 500 GeV center-of-mass and three options of beam parameters.

  13. On-line Observation Of Electron Beam Bunches In The Large Storage Ring Of Kurchatov Srs

    CERN Document Server

    Ioudin, L I; Krylov, Y V; Rezvov, V A; Stirin, A I; Valentinov, A G; Yupinov, Y L

    2004-01-01

    A complex of instrumentation for visual quantitative estimation of electron beam bunches in the big storage ring of Kurchatov Synchrotron Radiation Centre (KSRC) is tested. The bunches pass through a cylindrical electrostatic sensor whose signal is recorded by a wide-band oscillograph. The TV camera reads the optical image of the signal from the oscillograph screen. The TV signal numbering board inputs the video image to the computer memory. The monitor displays the beam bunch structure. A special program provides on-line visualisation of bunch behaviour on the beam orbit. The images of beam structure and a series of images showing the beam behaviour in the regimes of accumulation, acceleration and in the stationary regime a full power are numbered and stored.

  14. A logarithmic processor for Beam Position Measurements applied to a Transfer Line at CERN

    CERN Document Server

    Schmickler, Hermann

    2001-01-01

    The transfer line from the CERN proton synchrotron (PS) to the super proton synchrotron (SPS) requires a new beam position measurement system in view of the LHC. In this line, the single passage of various beam types (up to 7), induces signals with a global signal dynamics of more than 100 dB and with a wide frequency spectral distribution. Logarithmic amplifiers, have been chosen as technical solution for the challenges described above. The paper describes the details of the adopted solutions to make beam position measurements, with a resolution down to few 10-4 of the full pickup aperture over more than 50 dB of the total signal dynamics. The reported performances has been measured on the series production cards, already installed into the machine and on one pickup in the transfer line.

  15. Successful beam test of the SPS-to-LHC transfer line TI2

    CERN Multimedia

    2007-01-01

    Image of the first beam spot on the last BTV screen traversed by the beam during the TI 2 test.At 12:03:47 on 28 October a beam passed down the 2.7 km of the new SPS-to-LHC transfer line TI 2 at the first attempt, to within some 50 m of the LHC tunnel. After initial tuning, a range of measurements was carried out with a low intensity proton beam and preliminary analyses look good. After the test, no increase in radiation levels was found in either the LHC or ALICE, and the zones were rapidly opened again for access. As from next year TI 2 will regularly transport a beam from the SPS to the LHC injection point of Ring 1, near Point 2 (ALICE). The TI 8 transfer line, which will bring particles from the SPS to the injection point in Ring 2, near Point 8 (LHCb), was commissioned successfully with low intensity beam in 2004. The two LHC injection lines have a combined length of 5.6 km and comprise some seven hundred warm magnets. While a...

  16. Simulation and Field Measurement of Quadrupole Magnets for KOMAC 20MeV Beam line

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B. H.; Kim, H. S.; Song, Y. G.; Kwon, H. J.; Cho, Y. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, quadrupole magnets the same as installed at the beam line simulated and analyzed for magnetic fields. Also quadrupole magnets will be measured field stability and evaluated reliability on long time operation. Control system consisted of Labview program and communication method consisted of Ethernet and Rs-232 with optical fiber for devices safety from high voltage and/or high current. As a results the DC power supply is controlled, magnetic fields data is acquired and coil temperature is measured. Magnetic field with hall sensor and temperature with K-type thermo-couple are measured with conversion factor using by voltmeter. Korea Multi-purpose Accelerator Complex (KOMAC) was developed at Gyeongju in Korea in 2012. KOMAC including a 50-keV ion source, a 3-MeV RFQ, and a 100-MeV DTL. And beam line consists of 20-MeV and 100-MeV for user. Proton beam transferred from the linac to the beam line using by dipole magnets and transferred proton beam focused and decreased beam loss and by quadrupole magnets.

  17. Development of a low-energy, high-brightness $\\mu^+$ beam line

    CERN Document Server

    Eggenberger, A; Wichmann, G

    2016-01-01

    We are developing a beam line which compresses the phase space of a standard surface $\\mu^+$ beam by 10 orders of magnitude with an efficiency of $10^{-3}$. Phase space compression occurs in a He gas target and consists of three consecutive stages: Transverse (perpendicular to the beam axis) compression, longitudinal compression and re-extraction into vacuum. Transverse compression was observed for the first time and longitudinal compression has been measured to occur within 2.5 $\\mu$s with high efficiency.

  18. Accelerator and detector physics at the Bern medical cyclotron and its beam transport line

    Directory of Open Access Journals (Sweden)

    Auger Martin

    2016-03-01

    Full Text Available The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.

  19. Neutron beam line design of a white neutron source at CSNS

    Science.gov (United States)

    Jing, Hantao; Zhang, Liying; Tang, Jingyu; Ruan, Xichao; Ning, Changjun; Yu, Yongji; Wang, Pengcheng; Li, Qiang; Ren, Jie; Tang, Hongqing; Wang, Xiangqi

    2017-09-01

    China Spallation Neutron Source (CSNS), which is under construction, is a large scientific facility dedicated mainly for multi-disciplinary research on material characterization using neutron scattering techniques. The CSNS Phase-I accelerator will deliver a proton beam with an energy of 1.6 GeV and a pulse repetition rate of 25 Hz to a tungsten target, and the beam power is 100 kW. A white neutron source using the back-streaming neutrons through the incoming proton beam channel was proposed and is under construction. The back-streaming neutrons which are very intense and have good time structure are very suitable for nuclear data measurements. The white neutron source includes an 80-m neutron beam line, two experimental halls, and also six different types of spectrometers. The physics design of the beam line is presented in this paper, which includes beam optics and beam characterization simulations, with the emphasis on obtaining extremely low background. The first-batch experiments on nuclear data measurements are expected to be conducted in late 2017.

  20. Lessons from shielding retrofits at the LAMPF/LANSCE/PSR accelerator, beam lines and target facilities

    Energy Technology Data Exchange (ETDEWEB)

    Macek, R.J.

    1994-07-01

    The experience in the past 7 years to improve the shielding and radiation control systems at the Los Alamos Meson Physics Facility (LAMPF) and the Manuel Lujan Jr. Neutron Scattering Center (LANSCE) provides important lessons for the design of radiation control systems at future, high beam power proton accelerator facilities. Major issues confronted and insight gained in developing shielding criteria and in the use of radiation interlocks are discussed. For accelerators and beam lines requiring hands-on-maintenance, our experience suggests that shielding criteria based on accident scenarios will be more demanding than criteria based on routinely encountered beam losses. Specification and analysis of the appropriate design basis accident become all important. Mitigation by active protection systems of the consequences of potential, but severe, prompt radiation accidents has been advocated as an alternate choice to shielding retrofits for risk management at both facilities. Acceptance of active protection systems has proven elusive primarily because of the difficulty in providing convincing proof that failure of active systems (to mitigate the accident) is incredible. Results from extensive shielding assessment studies are presented including data from experimental beam spill tests, comparisons with model estimates, and evidence bearing on the limitations of line-of-sight attenuation models in complex geometries. The scope and significant characteristics of major shielding retrofit projects at the LAMPF site are illustrated by the project to improve the shielding beneath a road over a multiuse, high-intensity beam line (Line D).

  1. Design of the beam transport line and injection system of the compact storage ring for TTX

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In this article, we present the design of the beam transport line and injection system of the compact storage ring for the Tsinghua Thomson scattering X-ray (TTX) source. The layout of the beam transport line fits in with the limited available space. The injection system is simplified, consisting of only one single kicker; the stray field on the reference orbit is also reduced without the septum magnet. We choose a travelling wave kicker and present both 2D and 3D simulations for the structure design.

  2. Present Status And First Results of the Final Focus Beam Line at the KEK Accelerator Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bambade, P.; /Orsay /KEK, Tsukuba; Alabau Pons, M.; /Valencia U., IFIC; Amann, J.; /SLAC; Angal-Kalinin, D.; /Daresbury; Apsimon, R.; /Oxford U., JAI; Araki, S.; Aryshev, A.; /KEK, Tsukuba; Bai, S.; /Beijing, Inst. High Energy Phys.; Bellomo, P.; /SLAC; Bett, D.; /Oxford U., JAI; Blair, G.; /Royal Holloway, U. of London; Bolzon, B.; /Savoie U.; Boogert, S.; Boorman, G.; /Royal Holloway, U. of London; Burrows, P.N.; Christian, G.; Coe, P.; Constance, B.; /Oxford U., JAI; Delahaye, Jean-Pierre; /CERN; Deacon, L.; /Royal Holloway, U. of London; Elsen, E.; /DESY /Valencia U., IFIC /KEK, Tsukuba /Beijing, Inst. High Energy Phys. /Savoie U. /Fermilab /Ecole Polytechnique /KEK, Tsukuba /Kyungpook Natl. U. /KEK, Tsukuba /Pohang Accelerator Lab. /Kyoto U., Inst. Chem. Res. /Savoie U. /Daresbury /Tokyo U. /Royal Holloway, U. of London /Kyungpook Natl. U. /Pohang Accelerator Lab. /Tokyo U. /KEK, Tsukuba /SLAC /University Coll. London /KEK, Tsukuba /SLAC /Royal Holloway, U. of London /KEK, Tsukuba /Tokyo U. /SLAC /Tohoku U. /KEK, Tsukuba /Tokyo U. /Pohang Accelerator Lab. /Brookhaven /SLAC /Oxford U., JAI /SLAC /Orsay /KEK, Tsukuba /Oxford U., JAI /Orsay /Fermilab /Tohoku U. /Manchester U. /CERN /SLAC /Tokyo U. /KEK, Tsukuba /Oxford U., JAI /Hiroshima U. /KEK, Tsukuba /CERN /KEK, Tsukuba /Oxford U., JAI /Ecole Polytechnique /SLAC /Oxford U., JAI /Fermilab /SLAC /Liverpool U. /SLAC /Tokyo U. /SLAC /Tokyo U. /KEK, Tsukuba /SLAC /CERN

    2011-11-11

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  3. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, Jean-Pierre; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A -Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E -S; Kim, H -S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M -H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  4. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, J P; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E S; Kim, H S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F; 10.1103/PhysRevSTAB.13.042801

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  5. Two kaon correlations from Pb+Pb collisions at 160 AGeV from NA44

    CERN Document Server

    Reichhold, D M; Bøggild, H; Boissevain, J G; Bussmann, K; Christiansen, P; Di Torre, G; Dodd, J; Erazmus, B; Esumi, S; Fabjan, Christian Wolfgang; Fields, D E; Franz, A; Gaardhøje, J J; Hamelin, M; Hansen, A G; Hansen, O; Hardtke, D; Hecke, H V; Holzer, B E; Humanic, T; Hummel, P; Jacak, B V; Jayanti, R; Kaneta, M; Kohama, T; Kopytine, M; Ljubicic, T; Lörstad, B; Maeda, N; Martin, L; Matsumoto, N; Murray, M; Nishimura, S; Ohnishi, H; Paic, G; Pandey, S U; Piuz, François; Pluta, J; Polychronakos, V; Potekhin, M V; Poulard, G; Sakaguchi, A; Schmidt-Sørensen, J; Simon-Gillo, J; Sondheim, W E; Sugitate, T; Sullivan, J P; Sumi, Y; Williams, D; Willis, W J; Wolf, K; Xu, N; Zachary, D S

    1999-01-01

    K sup + K sup + correlations from Pb+Pb collisions at the CERN experiment NA44 will be presented. NA44 is a focussing spectrometer that uses the 160 AGeV Pb beam at the SPS and specializes in the detection of a few artices near mid-rapidity. A comparison of the results from pion and kaon correlations will be made, and the m sub t dependence of hadron correlations will also be discussed.

  6. Neutrino emissivity under neutral kaon condensation

    CERN Document Server

    Kubis, S

    2006-01-01

    Neutrino emissivity from neutron star matter with neutral kaon condensate is considered. It is shown that a new cooling channel is opened, and what is more, all previously known channels acquire the greater emissivity reaching the level of the direct URCA cycle in normal matter.

  7. Isospin violation in pion-kaon scattering

    CERN Document Server

    Kubis, B; Kubis, Bastian; Mei{\\ss}ner, Ulf-G.

    2002-01-01

    We consider strong and electromagnetic isospin violation in near-threshold pion-kaon scattering. At tree level, such effects are small for all physical channels. We work out the complete one-loop corrections to the process pi^- K^+ -> pi^0 K^0. They come out rather small. We also show that the corresponding radiative cross section is highly suppressed at threshold.

  8. Nonlinear Effect on Effective Mass of Kaon

    Institute of Scientific and Technical Information of China (English)

    LiXiguo; GuoYanrui; GaoYuan; JinGenming

    2003-01-01

    The study of hardron properties in dense medium crekted in relativistic heavy ion collision is a subject of considerable current interest. Of particular importance is the modification of kaon properties in-medium. The knowledge is useful for our understanding of both chiral symmetry restoration in dense matter and the properties of the dense nuclear matter existing in neutron stars.

  9. Neutrino emissivity under neutral kaon condensation

    OpenAIRE

    Kubis, Sebastian

    2005-01-01

    Neutrino emissivity from neutron star matter with neutral kaon condensate is considered. It is shown that a new cooling channel is opened, and what is more, all previously known channels acquire the greater emissivity reaching the level of the direct URCA cycle in normal matter.

  10. The Revival of Kaon Flavour Physics

    CERN Document Server

    Buras, Andrzej J

    2016-01-01

    After years of silence we should witness in the rest of this decade and in the next decade the revival of kaon flavour physics. This is not only because of the crucial measurements of the branching ratios for the rare decays $K^+\\to\\pi^+\

  11. Transfer line scattering model of therapeutic hadron beams and applications to nozzle and gantry optimization

    Science.gov (United States)

    Palm, M.; Benedikt, M.; Dorda, U.

    2013-01-01

    The field of hadron therapy is growing rapidly with several facilities currently being planned, under construction or in commissioning worldwide. In the “active scanning” irradiation technique, the target is irradiated using a narrow pencil beam that is scanned transversally over the target while the penetration depth is altered with the beam energy. Together, the target dose can thereby be conformed in all three dimensions to the shape of the tumor. For applications where a sharp lateral beam penumbra is required in order to spare critical organs from unwanted dose, beam size blowup due to scattering in on-line beam diagnostic monitors, air gaps and passive elements like the ripple filter must be minimized. This paper presents a model for transverse scattering of therapeutic hadron beams along arbitrary multislab geometries. The conventional scattering formulation, which is only applicable to a drift space, is extended to not only take beam optics into account, but also non-Gaussian transverse beam profiles which are typically obtained from the slow resonant extraction from a synchrotron. This work has been carried out during the design phase of the beam delivery system for MedAustron, an Austrian hadron therapy facility with first patient treatment planned for the end of 2015. Irradiation will be performed using active scanning with proton and carbon ion beams. As a direct application of the scattering model, design choices for the MedAustron proton gantry and treatment nozzles are evaluated with respect to the transverse beam profile at the focal point; in air and at the Bragg peak.

  12. Upgrades to the SPS-to-LHC Transfer Line Beam Stoppers for the LHC High-Luminosity Era

    CERN Document Server

    Kain, Verena; Fraser, Matthew; Goddard, Brennan; Meddahi, Malika; Perillo Marcone, Antonio; Steele, Genevieve; Velotti, Francesco

    2016-01-01

    Each of the 3 km long transfer lines between the SPS and the LHC is equipped with two beam stoppers (TEDs), one at the beginning of the line and one close to the LHC injection point, which need to absorb the full transferred beam. The beam stoppers are used for setting up the SPS extractions and transfer lines with beam without having to inject into the LHC. Energy deposition and thermo-mechanical simulations have, however, shown that the TEDs will not be robust enough to safely absorb the high intensity beams foreseen for the high-luminosity LHC era. This paper will summarize the simulation results and limitations for upgrading the beam stoppers. An outline of the hardware upgrade strategy for the TEDs together with modifications to the SPS extraction interlock system to enforce intensity limitations for beam on the beam stoppers will be given.

  13. Characterization of a tagged $\\gamma$-ray beam line at the DA$\\Phi$NE Beam Test Facility

    CERN Document Server

    Cattaneo, P W; Boffelli, F; Bulgarelli, A; Buonomo, B; Chen, A W; D'Ammando, F; Froysland, T; Fuschino, F; Galli, M; Gianotti, F; Giuliani, A; Longo, F; Marisaldi, M; Mazzitelli, G; Pellizzoni, A; Prest, M; Pucella, G; Quintieri, L; Rappoldi, A; Tavani, M; Trifoglio, M; Trois, A; Valente, P; Vallazza, E; Vercellone, S; Zambra, A; Barbiellini, G; Caraveo, P; Cocco, V; Costa, E; De Paris, G; Del Monte, E; Di Cocco, G; Donnarumma, I; Evangelista, Y; Feroci, M; Ferrari, A; Fiorini, M; Labanti, C; Lapshov, I; Lazzarotto, F; Lipari, P; Mastropietro, M; Mereghetti, S; Morelli, E; Moretti, E; Morselli, A; Pacciani, L; Perotti, F; Piano, G; Picozza, P; Pilia, M; Porrovecchio, G; Rapisarda, M; Rubini, A; Sabatini, S; Soffitta, P; Striani, E; Vittorini, V; Zanello, D; Colafrancesco, S; Giommi, P; Pittori, C; Santolamazza, P; Verrecchia, F; Salotti, L

    2011-01-01

    At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $\\gamma$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $\\gamma$ rays. A tagged $\\gamma$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $\\gamma$ rays through Bremsstrahlung in a position-sensitive target. The $\\gamma$-ray energy is deduced by difference with the post-Bremsstrahlung electron energy \\cite{prest}-\\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the...

  14. The Very Low 1-9 GeV/c Tertiary Beam Extension of the H8 Beam Line of CERN SPS

    CERN Document Server

    Efthymiopoulos, Ilias

    2016-01-01

    The H8 beam line on the North Area of CERN SPS is a multipurpose experimental secondary particle beam able to transport particles of various types (hadrons, electrons, muons and ions) in a large momentum range from 10 GeV/c up to the top SPS energy (400 or 450 GeV/C). During the 2003-2004 shutdown the beam line was modi?fied in order to accommodate a new tertiary beam line, able to produce and transport particles in the momentum range of 1 to 9 GeV/c. Such low momentum hadron and electron particle beams are requested by the LHC experiments in order to calibrate various sub-detector systems. The design and first performance results from this new tertiary beam are described here.

  15. Validation of Monte-Carlo simulations with measurements at the ICON beam-line at SINQ

    Energy Technology Data Exchange (ETDEWEB)

    Giller, L. [LRS, Physics Department, Ecole Polytechnique Federal de Lausanne, CH-1015 Lausanne (Switzerland); Filges, U. [LDM, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)], E-mail: uwe.filges@psi.ch; Kuehne, G. [ASQ, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Wohlmuther, M. [ABE, GFA Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Zanini, L. [ASQ, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2008-02-11

    ICON is the new cold neutron imaging facility at the neutron spallation source SINQ. The ICON facility is placed at beam-line S52 with direct view to the cold liquid D{sub 2} moderator. The beam-line includes a 4.4 m long collimation section followed by a 11 m long flight path to the imaging system. The essential part of the collimation section is composed of six revolving drums and a variable aperture wheel. Depending on the investigated object, different apertures are used. Measurements have shown that each setup has a different spatial neutron flux distribution and specific beam profiles. Measured beam profiles have been used to validate results of simulations coupling the Monte-Carlo program MCNPX with the neutron ray-tracing program McStas. In a first step, MCNPX was used to calculate neutron spectra closed to the SINQ target, at the entrance of the collimation section. These results served as an input for McStas where the beam-line itself was simulated. In the present paper, experimental and theoretical results will be compared and discussed.

  16. Validation of Monte-Carlo simulations with measurements at the ICON beam-line at SINQ

    Science.gov (United States)

    Giller, L.; Filges, U.; Kühne, G.; Wohlmuther, M.; Zanini, L.

    2008-02-01

    ICON is the new cold neutron imaging facility at the neutron spallation source SINQ. The ICON facility is placed at beam-line S52 with direct view to the cold liquid D 2 moderator. The beam-line includes a 4.4 m long collimation section followed by a 11 m long flight path to the imaging system. The essential part of the collimation section is composed of six revolving drums and a variable aperture wheel. Depending on the investigated object, different apertures are used. Measurements have shown that each setup has a different spatial neutron flux distribution and specific beam profiles. Measured beam profiles have been used to validate results of simulations coupling the Monte-Carlo program MCNPX with the neutron ray-tracing program McStas. In a first step, MCNPX was used to calculate neutron spectra closed to the SINQ target, at the entrance of the collimation section. These results served as an input for McStas where the beam-line itself was simulated. In the present paper, experimental and theoretical results will be compared and discussed.

  17. RESIDUAL GAS IONIZATION BEAM PROFILE MONITOR ON 40MeV H— BEAM TRANSPORT LINE

    Institute of Scientific and Technical Information of China (English)

    徐伟鹏; E.Takasaki

    1995-01-01

    The monitor is composed of a pair of electrodes,a single stage of microchannel plate,a phosphor screen,a CCD camera and a PC computer,To obtain a good uniform collecting field,forming electrodes system is used instead of that with a resistive divider,The readout system is performed by the phosphor screen and the CCD camera because the spatial resolution is not limited by the mechanical structure like the anode strip type and such video display system is very useful for beam studies and operation of the 40MeV linac,Besides,the design and test results are described in detail.

  18. Achieving Stability Requirements for Nanoprobe and Long Beam Lines at NSLS II. A Comprehensive Study

    Energy Technology Data Exchange (ETDEWEB)

    Simos,N.; Fallier, M.; Hill, J.; Berman, L.; Evans-Lutterodt, K.; Broadbent, A.

    2008-06-23

    Driven by beam stability requirements at the NSLS II synchrotron, such that the desired small beam sizes and high brightness are both realized and stable, a comprehensive study has been launched seeking to provide assurances that stability at the nanometer level at critical x-ray beam-lines, is achievable, given the natural and cultural vibration environment at the selected site. The study consists of (a) an extensive investigation of the site to evaluate the existing ground vibration, in terms of amplitude, frequency content and coherence, and (b) of a numerical study of wave propagation and interaction with the infrastructure of the sensitive lines. The paper presents results from both aspects of the study.

  19. In situ baking method for degassing of a kicker magnet in accelerator beam line

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Junichiro, E-mail: kamiya.junichiro@jaea.go.jp; Ogiwara, Norio; Yanagibashi, Toru; Kinsho, Michikazu [Japan Atomic Energy Agency, J-PARC Center, Ooaza Shirakata 2-4, Tokai, Naka, Ibaraki 319-1195 (Japan); Yasuda, Yuichi [SAKAGUCHI E.H VOC CORP., Sakura Dai-san Kogyodanchi 1-8-6, Osaku, Sakura, Chiba 285-0802 (Japan)

    2016-03-15

    In this study, the authors propose a new in situ degassing method by which only kicker magnets in the accelerator beam line are baked out without raising the temperature of the vacuum chamber to prevent unwanted thermal expansion of the chamber. By simply installing the heater and thermal radiation shield plates between the kicker magnet and the chamber wall, most of the heat flux from the heater directs toward the kicker magnet. The result of the verification test showed that each part of the kicker magnet was heated to above the target temperature with a small rise in the vacuum chamber temperature. A graphite heater was selected in this application to bake-out the kicker magnet in the beam line to ensure reliability and easy maintainability of the heater. The vacuum characteristics of graphite were suitable for heater operation in the beam line. A preliminary heat-up test conducted in the accelerator beam line also showed that each part of the kicker magnet was successfully heated and that thermal expansion of the chamber was negligibly small.

  20. Design of a support system for the vertical beam transfer lines of the ELENA project

    CERN Document Server

    Bozhkov, Kristiyan

    2016-01-01

    This report aims to present the design of a support system for the vertical beam transfer lines of the ELENA project. Two different designs can be found in this report. The mechanical strength and the structure performance of the support are analysed by a finite element model.

  1. Beam line I411 at MAX II--performance and first results

    CERN Document Server

    Baessler, M; Jurvansuu, M; Feifel, R; Forsell, J O; Tarso-Fonseca, P D; Kivimaeki, A; Sundin, S; Sorensen, S L; Nyholm, R; Bjoerneholm, O; Aksela, S; Svensson, S

    2001-01-01

    We report on the characteristics and first results from the soft X-ray beam line I411, based on an undulator at the third generation synchrotron facility MAX II, Sweden. The beam line is designed for high-resolution, angle-resolved electron spectroscopy on gases, liquids and solids. Main components are the modified SX700 monochromator and the end station, both of which were previously used at beam line 51 at MAX I. The end station is equipped with a rotatable SES-200 hemispherical electron-analyser. Before the end station, a one-metre section is reserved for exchangeable experimental set-ups. The usable photon energy range is 50-1500 eV and the photon flux is two orders of magnitudes higher compared to beam line 51. At 400 eV a resolving power of about 5700 in the first order of the monochromator grating could be obtained. In gas phase, a total electron energy resolution of 16 meV has been achieved. Detailed results on the undulator performance, flux, photon and electron energy resolution as well as some tech...

  2. The Fluka Linebuilder and Element Database: Tools for Building Complex Models of Accelerators Beam Lines

    CERN Document Server

    Mereghetti, A; Cerutti, F; Versaci, R; Vlachoudis, V

    2012-01-01

    Extended FLUKA models of accelerator beam lines can be extremely complex: heavy to manipulate, poorly versatile and prone to mismatched positioning. We developed a framework capable of creating the FLUKA model of an arbitrary portion of a given accelerator, starting from the optics configuration and a few other information provided by the user. The framework includes a builder (LineBuilder), an element database and a series of configuration and analysis scripts. The LineBuilder is a Python program aimed at dynamically assembling complex FLUKA models of accelerator beam lines: positions, magnetic fields and scorings are automatically set up, and geometry details such as apertures of collimators, tilting and misalignment of elements, beam pipes and tunnel geometries can be entered at user’s will. The element database (FEDB) is a collection of detailed FLUKA geometry models of machine elements. This framework has been widely used for recent LHC and SPS beam-machine interaction studies at CERN, and led to a dra...

  3. Results from Tests of the Muon Endcap Alignment System in the H8 Beam Line 2002

    CERN Document Server

    Amelung, C; Cerutti, F; Handrich, K; Hashemi, K S; Mair, K; Palestini, S; Rothberg, J E; Schricker, A; Trigger, I

    2003-01-01

    The ATLAS muon spectrometer endcap test setup assembled in the H8 beam line at CERN in 2002 consisted of six alignment bars and six MDT chambers, representing part of one octant of the endcap. These elements were equipped with a full set of alignment sensors, which were used to obtain a first appraisal of the performance of the alignment system.

  4. On-line beam monitoring for neutron capture therapy at the MIT Research Reactor

    Science.gov (United States)

    Harling, Otto K.; Moulin, Damien J.; Chabeuf, Jean-Michel; Solares, Guido R.

    1995-08-01

    Neutron capture therapy sets new requirements on the measurement and monitoring of the radiation fields used in this new form of therapy. Beams used for neutron capture therapy are comprised of mixed radiation fields which include slow, epithermal, and fast neutrons, as well as gamma rays. A computer-based beam monitoring system for epithermal or thermal neutron capture therapy is described. This system provides accurate, sensitive, and rapid on-line readout and recording of the various beam components. Readout of fluxes, fluences, and corresponding doses in the target are provided in color coded graphic analog as well as numerical form on the computer monitors. Variations in neutron spectrum or spatial distribution of the beam can be rapidly diagnosed with the aid of the monitor readout. Redundancy of fluence measurement is provided by an independent system using scalers and timers and by utilizing reactor power measuring instruments.

  5. Design of a large acceptance, high efficiency energy selection system for the ELIMAIA beam-line

    Science.gov (United States)

    Schillaci, F.; Maggiore, M.; Andó, L.; Cirrone, G. A. P.; Cuttone, G.; Romano, F.; Scuderi, V.; Allegra, L.; Amato, A.; Gallo, G.; Korn, G.; Leanza, R.; Margarone, D.; Milluzzo, G.; Petringa, G.

    2016-08-01

    A magnetic chicane based on four electromagnetic dipoles is going to be realized by INFN-LNS to be used as an Energy Selection System (ESS) for laser driven proton beams up to 300 MeV and C6+ up to 70 MeV/u. The system will provide, as output, ion beams with a contrallable energy spread varying from 5% up to 20% according to the aperture slit size. Moreover, it has a very wide acceptance in order to ensure a very high transmission efficiency and, in principle, it has been designed to be used also as an active energy modulator. This system is the core element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be developed by INFN-LNS (It) and installed at the ELI-Beamlines facility in Prague (Cz). ELIMED will be the first user's open transport beam-line where a controlled laser-driven ion beam will be used for multidisciplinary research. The definition of well specified characteristics, both in terms of performance and field quality, of the magnetic chicane is crucial for the system realization, for the accurate study of the beam dynamics and for the proper matching with the Permanent Magnet Quadrupoles (PMQs) used as a collection system already designed. Here, the design of the magnetic chicane is described in details together with the adopted solutions in order to realize a robust system form the magnetic point of view. Moreover, the first preliminary transport simulations are also described showing the good performance of the whole beam line (PMQs+ESS).

  6. Beam emittance measurements and simulations of injector line for radio frequency quadrupole

    Science.gov (United States)

    Mathew, Jose V.; Rao, S. V. L. S.; Pande, Rajni; Singh, P.

    2015-07-01

    A 400 keV deuteron (D+) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H+ and D+ beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D+ beam through the RFQ, while 95% transmission has been measured experimentally.

  7. Modeling the Biophysical Effects in a Carbon Beam Delivery Line using Monte Carlo Simulation

    CERN Document Server

    Cho, Ilsung; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-01-01

    Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion beam therapy. In this study the biological effectiveness of a carbon ion beam delivery system was investigated using Monte Carlo simulation. A carbon ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon beam transporting into media. An incident energy carbon ion beam in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model is applied to describe the RBE of 10% survival in human salivary gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetrating depth of the water phantom along the incident beam direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the water phantom depth.

  8. Modeling the biophysical effects in a carbon beam delivery line by using Monte Carlo simulations

    Science.gov (United States)

    Cho, Ilsung; Yoo, SeungHoon; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-09-01

    The Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion-beam therapy. In this study, the biological effectiveness of a carbon-ion beam delivery system was investigated using Monte Carlo simulations. A carbon-ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon-ion beam transport into media. An incident energy carbon-ion beam with energy in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model was applied to describe the RBE of 10% survival in human salivary-gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetration depth in the water phantom along the incident beam's direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE-weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the depth in the water phantom.

  9. Beam imaging in the injection line of the INFN-LNS superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Nicolosi, Dario, E-mail: dario.nicolosi@lns.infn.it; Cosentino, Luigi; Mascali, David; Pappalardo, Alfio; Castro, Maurizio; Celona, Luigi; Marchetta, Carmelo; Marletta, Salvatore; Maugeri, Antonio; Rifuggiato, Danilo; Seminara, Angelo; Gammino, Santo [INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy)

    2016-02-15

    A cheap and efficient diagnostic system for beam monitoring has been recently developed at INFN-LNS in Catania. It consists of a high sensitivity CCD camera detecting the light produced by an ion beam hitting the surface of a scintillating screen and a frame grabber for image acquisition. A scintillating screen, developed at INFN-LNS and consisting of a 2 μm BaF{sub 2} layer evaporated on an aluminium plate, has been tested by using {sup 20}Ne and {sup 40}Ar beams in the keV energy range. The CAESAR ECR ion source has been used for investigating the influence of the frequency and magnetic field tuning effects, the impact of the microwave injected power, and of the focusing solenoids along the low energy beam transport on the beam shape and current. These tests will allow to better understand the interplay between the plasma and beam dynamics and, moreover, to improve the transport efficiency along the low energy beam line and the matching with the superconducting cyclotron, particularly relevant in view of the expected upgrade of the machine.

  10. Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M. J.; Boilson, D.; Hemsworth, R. S.; Geli, F.; Graceffa, J.; Urbani, M.; Schunke, B.; Chareyre, J. [ITER Organisation, 13607 St. Paul-Lez-Durance Cedex (France); Dlougach, E.; Krylov, A. [RRC Kurchatov institute, 1, Kurchatov Sq, Moscow, 123182 (Russian Federation)

    2015-04-08

    The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER

  11. Line end shortening and application of novel correction algorithms in e-beam direct write

    Science.gov (United States)

    Freitag, Martin; Choi, Kang-Hoon; Gutsch, Manuela; Hohle, Christoph

    2011-03-01

    For the manufacturing of semiconductor technologies following the ITRS roadmap, we will face the nodes well below 32nm half pitch in the next 2~3 years. Despite being able to achieve the required resolution, which is now possible with electron beam direct write variable shaped beam (EBDW VSB) equipment and resists, it becomes critical to precisely reproduce dense line space patterns onto a wafer. This exposed pattern must meet the targets from the layout in both dimensions (horizontally and vertically). For instance, the end of a line must be printed in its entire length to allow a later placed contact to be able to land on it. Up to now, the control of printed patterns such as line ends is achieved by a proximity effect correction (PEC) which is mostly based on a dose modulation. This investigation of the line end shortening (LES) includes multiple novel approaches, also containing an additional geometrical correction, to push the limits of the available data preparation algorithms and the measurement. The designed LES test patterns, which aim to characterize the status of LES in a quick and easy way, were exposed and measured at Fraunhofer Center Nanoelectronic Technologies (CNT) using its state of the art electron beam direct writer and CD-SEM. Simulation and exposure results with the novel LES correction algorithms applied to the test pattern and a large production like pattern in the range of our target CDs in dense line space features smaller than 40nm will be shown.

  12. A beam monitoring and validation system for continuous line scanning in proton therapy

    Science.gov (United States)

    Klimpki, G.; Psoroulas, S.; Bula, C.; Rechsteiner, U.; Eichin, M.; Weber, D. C.; Lomax, A.; Meer, D.

    2017-08-01

    Line scanning represents a faster and potentially more flexible form of pencil beam scanning than conventional step-and-shoot irradiations. It seeks to minimize dead times in beam delivery whilst preserving the possibility of modulating the dose at any point in the target volume. Our second generation proton gantry features irradiations in line scanning mode, but it still lacks a dedicated monitoring and validation system that guarantees patient safety throughout the irradiation. We report on its design and implementation in this paper. In line scanning, we steer the proton beam continuously along straight lines while adapting the speed and/or current frequently to modulate the delivered dose. We intend to prevent delivery errors that could be clinically relevant through a two-stage system: safety level 1 monitors the beam current and position every 10 μs. We demonstrate that direct readings from ionization chambers in the gantry nozzle and Hall probes in the scanner magnets provide required information on current and position, respectively. Interlocks will be raised when measured signals exceed their predefined tolerance bands. Even in case of an erroneous delivery, safety level 1 restricts hot and cold spots of the physically delivered fraction dose to  ±36~mGy (±2% of 2~Gy biologically). In safety level 2—an additional, partly redundant validation step—we compare the integral line profile measured with a strip monitor in the nozzle to a forward-calculated prediction. The comparison is performed between two line applications to detect amplifying inaccuracies in speed and current modulation. This level can be regarded as an online quality assurance of the machine. Both safety levels use devices and functionalities already installed along the beamline. Hence, the presented monitoring and validation system preserves full compatibility of discrete and continuous delivery mode on a single gantry, with the possibility of switching between modes during the

  13. Design method for a laser line beam shaper of a general 1D angular power distribution

    Science.gov (United States)

    Oved, E.; Oved, A.

    2016-05-01

    Laser line is a beam of laser, spanned in one direction using a beam shaper to form a fan of light. This illumination tool is important in laser aided machine vision, 3D scanners, and remote sensing. For some applications the laser line should have a specific angular power distribution. If the distribution is nonsymmetrical, the beam shaper is required to be nonsymmetrical freeform, and its design process using optical design software is time consuming due to the long optimization process which usually converges to some local minimum. In this paper we introduce a new design method of a single element refractive beam shaper of any predefined general 1D angular power distribution. The method makes use of a notion of "prism space", a geometrical representation of all double refraction prisms, and any 1D beam shaper can be described by a continuous curve in this space. It is shown that infinitely many different designs are possible for any given power distribution, and it is explained how an optimal design is selected among them, based on criteria such as high transmission, low surface slopes, robustness to manufacturing errors etc. The method is non-parametric and hence does not require initial guess of a functional form, and the resultant optical surfaces are described by a sequence of points, rather than by an analytic function.

  14. Kaon Condensates, Nuclear Symmetry Energy and Cooling of Neutron Stars

    CERN Document Server

    Kubis, S

    2003-01-01

    The cooling of neutron stars by URCA processes in the kaon-condensed neutron star matter for various forms of nuclear symmetry energy is investigated. The kaon-nucleon interactions are described by a chiral lagrangian. Nuclear matter energy is parametrized in terms of the isoscalar contribution and the nuclear symmetry energy in the isovector sector. High density behaviour of nuclear symmetry energy plays an essential role in determining the composition of the kaon-condensed neutron star matter which in turn affects the cooling properties. We find that the symmetry energy which decreases at higher densities makes the kaon-condensed neutron star matter fully protonized. This effect inhibits strongly direct URCA processes resulting in slower cooling of neutron stars as only kaon-induced URCA cycles are present. In contrast, for increasing symmetry energy direct URCA processes are allowed in the almost whole density range where the kaon condensation exists.

  15. Nonequilibrium Weak Processes in Kaon Condensation; 2, Kinetics of condensation

    CERN Document Server

    Muto, T; Iwamoto, N; Muto, Takumi; Tatsumi, Toshitaka; Iwamoto, Naoki

    2000-01-01

    The kinetics of negatively charged kaon condensation in the early stages of a newly born neutron star is considered. The thermal kaon process, in which kaons are thermally produced by nucleon-nucleon collisions, is found to be dominant throughout the equilibration process. Temporal changes of the order parameter of the condensate and the number densities of the chemical species are obtained from the rate equations, which include the thermal kaon reactions as well as the kaon-induced Urca and the modified Urca reactions. It is shown that the dynamical evolution of the condensate is characterized by three stages: the first, prior to establishment of a condensate, the second, during the growth and subsequent saturation of the condensate, and the third, near chemical equilibrium. The connection between the existence of a soft kaon mode and the instability of the noncondensed state is discussed. Implications of the nonequilibrium process on the possible delayed collapse of a protoneutron star are also mentioned.

  16. Extraction of kaon production cross-sections in HARP

    CERN Document Server

    Schroeter, Raphael; Blondel, Alain; Cervera Villanueva, Anselmo

    Precise measurements of secondary yields in hadron-nucleus collisions in the few GeV/c region are relevant to several areas of particle physics, particularly experimental neutrino physics. In particular, measurements made at HARP can have a direct impact on the detailed understanding of the neutrino fluxes of several accelerator-based neutrino experiments, including the K2K experiment in Japan and MiniBooNE and SciBooNE at Fermilab. HARP took data with these exact beam energies and target materials using both thin and thick targets. Strange particle production in the forward direction must be well known when trying to determine the ve background in a vµ beam, since Ke3 decays of K± and K0L constitute an irreducible background in the search of the vµ -> ve oscillations. This applies particularly to experiments such as MiniBooNE where G4 simulations showed that kaon decays contribute to more than 40% of the total intrinsic ve background of the beam. A complete analysis method has been developed to extract th...

  17. In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

    Science.gov (United States)

    Shao, Yiping; Sun, Xishan; Lou, Kai; Zhu, Xiaorong R.; Mirkovic, Dragon; Poenisch, Falk; Grosshans, David

    2014-07-01

    We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered ˜50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180° were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A 22Na disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.

  18. Design and performance of the beam transfer lines for the HIE-ISOLDE Project

    CERN Document Server

    Parfenova, A; Bauche, J; Cantero, E D; Farantatos, P; Fraser, M A; Goddard, B; Kadi, Y; Kolehmainen, A J; Lanaia, D; Martino, M; Mompo, R; Siesling, E; Sosa, A G; Timmins, M; Vandoni, G; Voulot, D; Zografos, E

    2013-01-01

    Beam design and beam optics studies for the HIE-ISOLDE transfer lines [1] have been carried out in MadX [2], and benchmarked against Trace3D results [3, 4]. Magnet field errors and alignment imperfections leading to deviations from design parameters have been treated explicitly, and the sensitivity of the machine lattice to different individual error sources was studied. As a result, the tolerances for the various error-contributions have been specified for the different equipment systems. The design choices for the expected magnet field and power supply quality, alignment tolerances, instrument resolution and physical aperture were validated. The methodology and results of the studies are presented.

  19. Weak Kaon Production off the Nucleon

    CERN Document Server

    Alam, M Rafi; Athar, M Sajjad; Vacas, M J Vicente

    2010-01-01

    The weak kaon production off the nucleon induced by neutrinos is studied at the low and intermediate energies of interest for some ongoing and future neutrino oscillation experiments. This process is also potentially important for the analysis of proton decay experiments. We develop a microscopical model based on the SU(3) chiral Lagrangians. The basic parameters of the model are fpi, the pion decay constant, Cabibbo's angle, the proton and neutron magnetic moments and the axial vector coupling constants for the baryons octet, D and F, that are obtained from the analysis of the semileptonic decays of neutron and hyperons. The studied mechanisms are the main source of kaon production for neutrino energies up to 1.2 to 1.5 GeV for the various channels and the cross sections are large enough to be amenable to be measured by experiments such as Minerva and T2K.

  20. Power production experiments at the Test Beam Line in the CLIC Test Facility 3

    CERN Document Server

    Lillestøl, Reidar Lunde; Adli, Erik; Lundheim, Lars Magne

    2010-01-01

    CLIC is an international study of a future multi-TeV electron-positron linear collider, where the energy of a high-intensity drive beam is extracted and transferred to the main beam via Power Extraction and Transfer Structures (PETS) in the form of rf power. The study of power production is therefore essential for the feasibility of CLIC. Power production in PETS has been studied, and ex- periments have been performed in the decelerator Test Beam Line in the CLIC Test Facility 3. In particular, the correlation of the power production and the beam position inside the structure has been studied. It is shown that the total produced power is constant when the beam has a position offset through the PETS. In addition, the difference between the measured phases from each side is independent of the beam position, which allows for efficient combination of the fields. However, the ratio of the power on each side of the PETS unexpectedly shows a linear dependence on the horizontal offset, with a correlation value of 0.8...

  1. Mechanical Design of a Heavy Ion Beam Dump for the RIA Fragmentation Line

    CERN Document Server

    Stein, Werner; Conner, David L

    2005-01-01

    The RIA fragmentation line requires a beam stop for the primary beam downstream of the first dipole magnet. The beam may consist of U, Ca, Sn, Kr, or O ions. with a variety of power densities. The configuration with highest power density is for the U beam, with a spot size of 3 cm x 3 cm and a total power of up to 300 kW. The mechanical design of the dump that meets these criteria consists of a 50 cm diameter aluminum wheel with water coolant channels. A hollow drive shaft supplies the coolant water and connects the wheel to an electrical motor located in an air space in the floor above the dump. The beam strikes the wheel along the outer perimeter and passes through a thin window of aluminum where 10% of its power is absorbed and the remainder of the beam is absorbed in flowing water behind the window. Rotation of the wheel at 400 RPM results in maximum aluminum temperatures below 100 C and acceptably low thermal stresses of 5 ksi. Rotating the wheel also results in low radiation damage levels by spreading t...

  2. SIMULATION OF NEUTRON BACKGROUNDS FROM THE ILC EXTRACTION LINE BEAM DUMP

    Energy Technology Data Exchange (ETDEWEB)

    Darbha, S; Keller, L.; Maruyama, T.

    2008-01-01

    The operation of the International Linear Collider (ILC) as a precision measurement machine is dependent upon the quality of the charge-coupled device (CCD) silicon vertex detector. An integrated fl ux of 1010 neutrons/cm2 incident upon the vertex detector will degrade its performance by causing displacement damage in the silicon. One source of the neutron background arises from the dumping of the spent electron and positron beams into the extraction line beam dumps. The Monte Carlo program FLUKA was used to simulate the collision of the electron beam with the dump and to determine the resulting neutron fl ux at the interaction point (IP). A collimator and tunnel were added and their effect on the fl ux was analyzed. A neutron source was then generated and directed along the extraction line towards a model of the vertex detector to determine the neutron fl ux in its silicon layers. Models of the beampipe and BeamCal, a silicon-tungsten electromagnetic calorimeter in the very forward region of the detector, were placed in the extraction line and their effects on scattering were studied. The IP fl uence was determined to be 3.7x1010 +/- 2.3x1010 neutrons/cm2/year when the tunnel and collimator were in place, with no appreciable increase in statistics when the tunnel was removed. The BeamCal was discovered to act as a collimator by signifi cantly impeding the fl ow of neutrons towards the detector. The majority of damage done to the fi rst layer of the detector was found to come from neutrons with a direct line of sight from the fi rst extraction line quadrupole QDEX1, with only a small fraction scattering off of the beampipe and into the detector. The 1 MeV equivalent neutron fl uence was determined to be 9.3x108 neutrons/cm2/year from the electron beam alone. The two beams collectively contribute double to this fl uence, which is 19% of the threshold value in one year. Future work will improve the detector model and other sources of neutron backgrounds will be

  3. Loop corrections to pion and kaon neutrinoproduction

    CERN Document Server

    Siddikov, Marat

    2016-01-01

    In this paper we study the next-to-leading order corrections to deeply virtual pion and kaon production in neutrino experiments. We estimate these corrections in the kinematics of the Minerva experiment at FERMILAB, and find that they are sizable and increase the leading order cross-section by up to a factor of two. We provide a code, which can be used for the evaluation of the cross-sections, taking into account these corrections and employing various GPD models.

  4. CALCULATION OF KAON ELECTROMAGNETIC FORM FACTOR

    Institute of Scientific and Technical Information of China (English)

    WANG ZHI-GANG; WAN SHAO-LONG; WANG KE-LIN

    2001-01-01

    The kaon meson electromagnetic form factor is calculated in the framework of coupled Schwinger-Dyson and Bethe-Salpeter formulation in simplified impulse approximation (dressed vertex) with modified fiat-bottom potential,which is a combination of the flat-bottom potential taking into consideration the infrared and ultraviolet asymptotic behaviours of the effective quark-gluon coupling. All the numerical results give a good fit to experimental values.

  5. Non-perturbative renormalization in kaon decays

    CERN Document Server

    Donini, Andrea; Martinelli, G; Rossi, G C; Talevi, M; Testa, M; Vladikas, A

    1996-01-01

    We discuss the application of the MPSTV non-perturbative method \\cite{NPM} to the operators relevant to kaon decays. This enables us to reappraise the long-standing question of the $\\Delta I=1/2$ rule, which involves power-divergent subtractions that cannot be evaluated in perturbation theory. We also study the mixing with dimension-six operators and discuss its implications to the chiral behaviour of the $B_K$ parameter.

  6. A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line.

    Science.gov (United States)

    Romano, F; Cirrone, G A P; Cuttone, G; Rosa, F Di; Mazzaglia, S E; Petrovic, I; Fira, A Ristic; Varisano, A

    2014-06-21

    Fluence, depth absorbed dose and linear energy transfer (LET) distributions of proton and carbon ion beams have been investigated using the Monte Carlo code Geant4 (GEometry ANd Tracking). An open source application was developed with the aim to simulate two typical transport beam lines, one used for ocular therapy and cell irradiations with protons and the other for cell irradiations with carbon ions. This tool allows evaluation of the primary and total dose averaged LET and predict their spatial distribution in voxelized or sliced geometries. In order to reproduce the LET distributions in a realistic way, and also the secondary particles' contributions due to nuclear interactions were considered in the computations. Pristine and spread-out Bragg peaks were taken into account both for proton and carbon ion beams, with the maximum energy of 62 MeV/n. Depth dose distributions were compared with experimental data, showing good agreement. Primary and total LET distributions were analysed in order to study the influence of contributions of secondary particles in regions at different depths. A non-negligible influence of high-LET components was found in the entrance channel for proton beams, determining the total dose averaged LET by the factor 3 higher than the primary one. A completely different situation was obtained for carbon ions. In this case, secondary particles mainly contributed in the tail that is after the peak. The results showed how the weight of light and heavy secondary ions can considerably influence the computation of LET depth distributions. This has an important role in the interpretation of results coming from radiobiological experiments and, therefore, in hadron treatment planning procedures.

  7. A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line

    Science.gov (United States)

    Romano, F.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Mazzaglia, S. E.; Petrovic, I.; Ristic Fira, A.; Varisano, A.

    2014-06-01

    Fluence, depth absorbed dose and linear energy transfer (LET) distributions of proton and carbon ion beams have been investigated using the Monte Carlo code Geant4 (GEometry ANd Tracking). An open source application was developed with the aim to simulate two typical transport beam lines, one used for ocular therapy and cell irradiations with protons and the other for cell irradiations with carbon ions. This tool allows evaluation of the primary and total dose averaged LET and predict their spatial distribution in voxelized or sliced geometries. In order to reproduce the LET distributions in a realistic way, and also the secondary particles’ contributions due to nuclear interactions were considered in the computations. Pristine and spread-out Bragg peaks were taken into account both for proton and carbon ion beams, with the maximum energy of 62 MeV/n. Depth dose distributions were compared with experimental data, showing good agreement. Primary and total LET distributions were analysed in order to study the influence of contributions of secondary particles in regions at different depths. A non-negligible influence of high-LET components was found in the entrance channel for proton beams, determining the total dose averaged LET by the factor 3 higher than the primary one. A completely different situation was obtained for carbon ions. In this case, secondary particles mainly contributed in the tail that is after the peak. The results showed how the weight of light and heavy secondary ions can considerably influence the computation of LET depth distributions. This has an important role in the interpretation of results coming from radiobiological experiments and, therefore, in hadron treatment planning procedures.

  8. Millimeter-wave Line Ratios and Sub-beam Volume Density Distributions

    Science.gov (United States)

    Leroy, Adam K.; Usero, Antonio; Schruba, Andreas; Bigiel, Frank; Kruijssen, J. M. Diederik; Kepley, Amanda; Blanc, Guillermo A.; Bolatto, Alberto D.; Cormier, Diane; Gallagher, Molly; Hughes, Annie; Jiménez-Donaire, Maria J.; Rosolowsky, Erik; Schinnerer, Eva

    2017-02-01

    We explore the use of mm-wave emission line ratios to trace molecular gas density when observations integrate over a wide range of volume densities within a single telescope beam. For observations targeting external galaxies, this case is unavoidable. Using a framework similar to that of Krumholz & Thompson, we model emission for a set of common extragalactic lines from lognormal and power law density distributions. We consider the median density of gas that produces emission and the ability to predict density variations from observed line ratios. We emphasize line ratio variations because these do not require us to know the absolute abundance of our tracers. Patterns of line ratio variations have the potential to illuminate the high-end shape of the density distribution, and to capture changes in the dense gas fraction and median volume density. Our results with and without a high-density power law tail differ appreciably; we highlight better knowledge of the probability density function (PDF) shape as an important area. We also show the implications of sub-beam density distributions for isotopologue studies targeting dense gas tracers. Differential excitation often implies a significant correction to the naive case. We provide tabulated versions of many of our results, which can be used to interpret changes in mm-wave line ratios in terms of adjustments to the underlying density distributions.

  9. Sterile neutrinos facing kaon physics experiments

    Science.gov (United States)

    Abada, A.; Bečirević, D.; Sumensari, O.; Weiland, C.; Funchal, R. Zukanovich

    2017-04-01

    We discuss weak kaon decays in a scenario in which the Standard Model is extended by massive sterile fermions. After revisiting the analytical expressions for leptonic and semileptonic decays we derive the expressions for decay rates with two neutrinos in the final state. By using a simple effective model with only one sterile neutrino, compatible with all current experimental bounds and general theoretical constraints, we conduct a thorough numerical analysis which reveals that the impact of the presence of massive sterile neutrinos on kaon weak decays is very small, less than 1% on decay rates. The only exception is B (KL→ν ν ) , which can go up to O (10-10), thus possibly within the reach of the KOTO, NA62 and SHIP experiments. Plans have also been proposed to search for this decay at the NA64 experiment. In other words, if all the future measurements of weak kaon decays turn out to be compatible with the Standard Model predictions, this will not rule out the existence of massive light sterile neutrinos with non-negligible active-sterile mixing. Instead, for a sterile neutrino of mass below mK, one might obtain a huge enhancement of B (KL→ν ν ), otherwise negligibly small in the Standard Model.

  10. Extension of Pierce model to multiple transmission lines interacting with an electron beam

    CERN Document Server

    Tamma, Venkata Ananth

    2013-01-01

    A possible route towards achieving high power microwave devices is through the use of novel slow-wave structures employing multiple coupled transmission lines (MTLs) whose behavior when coupled to electron beams have not been sufficiently explored. We present the extension of the one-dimensional linearized Pierce theory to MTLs coupled to a single electron beam. We develop multiple formalisms to calculate the k-{\\omega} dispersion relation of the system and find that the existence of a growing wave solution is always guaranteed if the electron propagation constant is larger than or equal to the largest propagation constant of the MTL system. We verify our findings with illustrative examples which bring to light unique properties of the system in which growing waves were found to exist within finite bands of the electron propagation constant and discuss possible approach to improve the gain. By treating the beam-MTL interaction as distributed dependent current generators in the MTL, we derive relations charact...

  11. Confocal line scanning of a Bessel beam for fast 3D imaging.

    Science.gov (United States)

    Zhang, P; Phipps, M E; Goodwin, P M; Werner, J H

    2014-06-15

    We have developed a light-sheet illumination microscope that can perform fast 3D imaging of transparent biological samples with inexpensive visible lasers and a single galvo mirror (GM). The light-sheet is created by raster scanning a Bessel beam with a GM, with this same GM also being used to rescan the fluorescence across a chip of a camera to construct an image in real time. A slit is used to reject out-of-focus fluorescence such that the image formed in real time has minimal contribution from the sidelobes of the Bessel beam. Compared with two-photon Bessel beam excitation or other confocal line-scanning approaches, our method is of lower cost, is simpler, and does not require calibration and synchronization of multiple GMs. We demonstrated the optical sectioning and out-of-focus background rejection capabilities of this microscope by imaging fluorescently labeled actin filaments in fixed 3T3 cells.

  12. Evaporating droplet hologram simulation for digital in-line holography setup with divergent beam.

    Science.gov (United States)

    Méès, Loïc; Grosjean, Nathalie; Chareyron, Delphine; Marié, Jean-Louis; Seifi, Mozhdeh; Fournier, Corinne

    2013-10-01

    Generalized Lorenz-Mie theory (GLMT) for a multilayered sphere is used to simulate holograms produced by evaporating spherical droplets with refractive index gradient in the surrounding air/vapor mixture. Simulated holograms provide a physical interpretation of experimental holograms produced by evaporating Diethyl Ether droplets with diameter in the order of 50 μm and recorded in a digital in-line holography configuration with a divergent beam. Refractive index gradients in the surrounding medium lead to a modification of the center part of the droplet holograms, where the first fringe is unusually bright. GLMT simulations reproduce this modification well, assuming an exponential decay of the refractive index from the droplet surface to infinity. The diverging beam effect is also considered. In both evaporating and nonevaporating cases, an equivalence is found between Gaussian beam and plane wave illuminations, simply based on a magnification ratio to be applied to the droplets' parameters.

  13. Proposal for characterization of muon spectrometers for neutrino beam lines with the Baby MIND

    CERN Document Server

    Noah, E

    2015-01-01

    Neutrino detectors based on state-of-the-art plastic scintillators read out with solid state photo-sensors, as well as new magnetization schemes, have been developed in the framework of AIDA. Meaningful size prototypes are under construction. In the framework of the CERN neutrino platform, we propose to test a Totally Active Scintillator Detector (TASD) and a prototype of a Magnetized Iron Neutrino Detector (MIND), called Baby MIND in the H8 beam line in 2016-2018. The design of the detectors and the purpose and plans for the beam tests are presented. An opportunity to use the Baby MIND detector in a real neutrino beam at JPARC for the measurement of the cross-section ratio between Water and scintillator (WAGASCI experiment) is described.

  14. A closed-form solution to a viscoelastically supported Timoshenko beam under harmonic line load

    Science.gov (United States)

    Luo, W. L.; Xia, Y.; Zhou, X. Q.

    2016-05-01

    This study aims to formulate a closed-form solution to a viscoelastically supported Timoshenko beam under a harmonic line load. The differential governing equations of motion are converted into algebraic equations by assuming the deflection and rotation of the beam in harmonic forms with respect to time and space. The characteristic equation is biquadratic and thus contains 14 explicit roots. These roots are then substituted into Cauchy's residue theorem; consequently, five forms of the closed-form solution are generated. The present solution is consistent with that of an Euler-Bernoulli beam on a Winkler foundation, which is a special case of the present problem. The current solution is also verified through numerical examples.

  15. Dosimetric characterization and application of an imaging beam line with a carbon electron target for megavoltage cone beam computed tomography.

    Science.gov (United States)

    Flynn, Ryan T; Hartmann, Julia; Bani-Hashemi, Ali; Nixon, Earl; Alfredo, R; Siochi, C; Pennington, Edward C; Bayouth, John E

    2009-06-01

    Imaging dose from megavoltage cone beam computed tomography (MVCBCT) can be significantly reduced without loss of image quality by using an imaging beam line (IBL), with no flattening filter and a carbon, rather than tungsten, electron target. The IBL produces a greater keV-range x-ray fluence than the treatment beam line (TBL), which results in a more optimal detector response. The IBL imaging dose is not necessarily negligible, however. In this work an IBL was dosimetrically modeled with the Philips Pinnacle3 treatment planning system (TPS), verified experimentally, and applied to clinical cases. The IBL acquisition dose for a 200 degrees gantry rotation was verified in a customized acrylic cylindrical phantom at multiple imaging field sizes with 196 ion chamber measurements. Agreement between the measured and calculated IBL dose was quantified with the 3D gamma index. Representative IBL and TBL imaging dose distributions were calculated for head and neck and prostate patients and included in treatment plans using the imaging dose incorporation (IDI) method. Surface dose was measured for the TBL and IBL for four head and neck cancer patients with MOSFETs. The IBL model, when compared to the percentage depth dose and profile measurements, had 97% passing gamma indices for dosimetric and distance acceptance criteria of 3%, 3 mm, and 100% passed for 5.2%, 5.2 mm. For the ion chamber measurements of phantom image acquisition dose, the IBL model had 93% passing gamma indices for acceptance criteria of 3%, 3 mm, and 100% passed for 4%, 4 mm. Differences between the IBL- and TBL-based IMRT treatment plans created with the IDI method were dosimetrically insignificant for both the prostate and head and neck cases. For IBL and TBL beams with monitor unit values that would result in the delivery of the same dose to the depth of maximum dose under standard calibration conditions, the IBL imaging surface dose was higher than the TBL imaging surface dose by an average of 18

  16. The Beam Line X NdFe-steel hybrid wiggler for SSRL

    Energy Technology Data Exchange (ETDEWEB)

    Hoyer, E.; Halbach, K.; Humphries, D.; Marks, S.; Plate, D.; Shuman, D.; Karpenko, V.P.; Kulkarni, S.; Tirsell, K.G.

    1987-03-10

    A wiggler magnet with 15 periods, each 12.85 cm long, which achieves 1.40 T at a 2.1 cm gap (2.26T at 0.8 cm) has been designed and is now in fabrication at LBL. This wiggler will be the radiation source of the high intensity synchrotron radiation beam line for the Beam Line X PRT facility at SSRL. The magnet utilizes Neodymium-Iron (NdFe) material and Vanadium Permendur (steel) in the hybrid configuration to achieve simultaneously a high magnetic field and short period. Magnetic field adjustment is with a driven chain and ball screw drive system. The magnetic structure is external to an s.s. vacuum chamber which has thin walls, 0.76 mm thickness, at each pole tip for higher field operation. Magnetic design, construction details and magnetic measurements are presented.

  17. National Synchrotron Light Source users manual: Guide to the VUV and x-ray beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.F.; White-DePace, S.M. (eds.)

    1987-08-01

    The success of the National Synchrotron Light Source in the years to come will be based, in large part, on the size of the users community and the diversity of the scientific disciplines represented by these users. In order to promote this philosophy, this National Synchrotron Light Source (NSLS) Users Manual: Guide to the VUV and X-Ray Beam Lines, has been published. This manual serves a number of purposes. In an effort to attract new research, it will present to the scientific community-at-large the current and projected architecture and capabilities of the various VUV and x-ray beam lines and storage rings. We anticipate that this publication will be updated periodically in order to keep pace with the constant changes at the NSLS.

  18. Automation of beam based alignment for the PAL-XFEL undulator line

    Energy Technology Data Exchange (ETDEWEB)

    Parc, Yong Woon; Hwang, Ilmoon [Pohang Accelerator Laboratory, Pohang 790-784 (Korea, Republic of); Han, Jang-Hui, E-mail: janghui_han@postech.ac.kr [Pohang Accelerator Laboratory, Pohang 790-784 (Korea, Republic of); Ko, In Soo [Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2015-05-11

    An automated method of quadrupole beam based alignment in an X-ray free electron laser (XFEL) undulator line is proposed. To realize the automatic beam based alignment (BBA) independently of operator's skill and efforts, the procedure is simplified. Simulation results on the BBA technique using two alignment stages for the Pohang Accelerator Laboratory XFEL's (PAL-XFEL) undulator line is carried out. After a standard mechanical alignment the quadrupoles are expected to be aligned to 100 μm rms from our previous experience. A rough alignment method in this study is able to align the quadrupoles to about 40 μm rms without any pre-handling of electron beam orbit or quadrupoles position. At the second stage, the singular value decomposition (SVD) method is applied to perform a fine alignment in which the trajectory of an electron beam is controlled within 5 μm rms to the ideal orbit. All procedures are programmable to perform the BBA automatically.

  19. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  20. Semi-empirical model for fluorescence lines evaluation in diagnostic x-ray beams.

    Science.gov (United States)

    Bontempi, Marco; Andreani, Lucia; Labanti, Claudio; Costa, Paulo Roberto; Rossi, Pier Luca; Baldazzi, Giuseppe

    2016-01-01

    Diagnostic x-ray beams are composed of bremsstrahlung and discrete fluorescence lines. The aim of this study is the development of an efficient model for the evaluation of the fluorescence lines. The most important electron ionization models are analyzed and implemented. The model results were compared with experimental data and with other independent spectra presented in the literature. The implemented peak models allow the discrimination between direct and indirect radiation emitted from tungsten anodes. The comparison with the independent literature spectra indicated a good agreement.

  1. Off-line production of intense {sup 7,10}Be{sup +} beams

    Energy Technology Data Exchange (ETDEWEB)

    Koester, U. E-mail: ulli.koster@cern.ch; Argentini, M.; Catherall, R.; Fedoseyev, V.N.; Gaeggeler, H.W.; Jonsson, O.C.; Weinreich, R

    2003-05-01

    {sup 7}Be and {sup 10}Be were produced by 590 MeV proton bombardment of a graphite target at PSI. Parts of this graphite target were transferred into an ISOLDE target and ion source unit and ionized with the ISOLDE resonance ionization laser ion source. Thus intense radioactive ion beams of 300 nA of {sup 7,10}Be{sup +} were produced off-line.

  2. Off-line production of intense $^{7,10}Be^{+}$ beams

    CERN Document Server

    Köster, U; Catherall, R; Fedosseev, V; Gäggeler, H W; Jonsson, O C; Weinreich, R

    2003-01-01

    $^7$Be and $^{10}$Be were produced by 590~MeV proton bombardment of a graphite target at PSI. Parts of this graphite target were transferred into an ISOLDE target and ion source unit and ionized with the ISOLDE resonance ionization laser ion source (RILIS). Thus intense radioactive ion beams of 300~nA of $^{7,10}$Be$^+$ were produced off-line.

  3. Improved design of proton source and low energy beam transport line for European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Neri, L., E-mail: neri@lns.infn.it; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Ciavola, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Torrisi, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria dell’Informazione, delle Infrastrutture e dell’Energia Sostenibile, Università Mediterranea di Reggio Calabria, Via Graziella, 89122 Reggio Calabria (Italy); Cheymol, B.; Ponton, A. [European Spallation Source ESS AB, Lund (Sweden); Galatà, A. [Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Patti, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Gozzo, A.; Lega, L. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria Informatica e delle Telecomunicazioni, Università degli Studi di Catania, Viale Andrea Doria 6, 95123 Catania (Italy)

    2014-02-15

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  4. Light-sheet microscopy by confocal line scanning of dual-Bessel beams.

    Science.gov (United States)

    Zhang, Pengfei; Phipps, Mary E; Goodwin, Peter M; Werner, James H

    2016-10-01

    We have developed a light-sheet microscope that uses confocal scanning of dual-Bessel beams for illumination. A digital micromirror device (DMD) is placed in the intermediate image plane of the objective used to collect fluorescence and is programmed with two lines of pixels in the “on” state such that the DMD functions as a spatial filter to reject the out-of-focus background generated by the side-lobes of the Bessel beams. The optical sectioning and out-of-focus background rejection capabilities of this microscope were demonstrated by imaging of fluorescently stained actin in human A431 cells. The dual-Bessel beam system enables twice as many photons to be detected per imaging scan, which is useful for low light applications (e.g., single-molecule localization) or imaging at high speed with a superior signal to noise. While demonstrated for two Bessel beams, this approach is scalable to a larger number of beams.

  5. Improved design of proton source and low energy beam transport line for European Spallation Source

    Science.gov (United States)

    Neri, L.; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Torrisi, G.; Cheymol, B.; Ponton, A.; Galatà, A.; Patti, G.; Gozzo, A.; Lega, L.; Ciavola, G.

    2014-02-01

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  6. Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results

    Science.gov (United States)

    Garg, Akash Deep; Karnewar, A. K.; Ojha, A.; Shrivastava, B. B.; Holikatti, A. C.; Puntambekar, T. A.; Navathe, C. P.

    2014-08-01

    Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8-18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 μm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.

  7. Design of medium energy beam transport line between the RFQ and the Linac in the radioactive ion beam facility at VECC, Kolkata

    Indian Academy of Sciences (India)

    S Dechoudhury; Vaishali Naik; Manas Mondal; Hemendra Kumar Pandey; Avik Chatterjee; Dirtha Sanyal; Debasis Bhowmick; Alok Chakrabarti

    2010-09-01

    The design of a medium energy beam transport (MEBT) line comprising of a re-buncher and four quadrupoles, two upstream and the other two downstream of the re-buncher, has been presented. The design was done to ensure almost 100% transport of heavy-ion beams of about 99 keV/u energy from RFQ having a / not less than 1/14 through the re-buncher and then through IH Linac of about 0.6 m length in which beam would be accelerated to about 185 keV/u. The re-buncher has been designed to operate at 37.8 MHz, the resonating frequency of both the RFQ and the IH Linac. The entire beam line has been installed and recently O5+ beam from RFQ has been transported through the re-buncher and subsequently accelerated in the IH Linac successfully.

  8. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    Directory of Open Access Journals (Sweden)

    2010-04-01

    Full Text Available ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  9. On-line neutron beam monitoring of the Finnish BNCT facility

    Science.gov (United States)

    Tanner, Vesa; Auterinen, Iiro; Helin, Jori; Kosunen, Antti; Savolainen, Sauli

    1999-02-01

    A Boron Neutron Capture Therapy (BNCT) facility has been built at the FiR 1 research reactor of VTT Chemical Technology in Espoo, Finland. The facility is currently undergoing dosimetry characterisation and neutron beam operation research for clinical trials. The healthy tissue tolerance study, which was carried out in the new facility during spring 1998, demonstrated the reliability and user-friendliness of the new on-line beam monitoring system designed and constructed for BNCT by VTT Chemical Technology. The epithermal neutron beam is monitored at a bismuth gamma shield after an aluminiumfluoride-aluminium moderator. The detectors are three pulse mode U 235-fission chambers for epithermal neutron fluence rate and one current mode ionisation chamber for gamma dose rate. By using different detector sensitivities the beam intensity can be measured over a wide range of reactor power levels (0.001-250 kW). The detector signals are monitored on-line with a virtual instrumentation (LabView) based PC-program, which records and displays the actual count rates and total counts of the detectors in the beam. Also reactor in-core power instrumentation and control rod positions can be monitored via another LabView application. The main purpose of the monitoring system is to provide a dosimetric link to the dose in a patient during the treatment, as the fission chamber count rates have been calibrated to the induced thermal neutron fluence rate and to the absorbed dose rate at reference conditions in a tissue substitute phantom.

  10. The diffusive instability of kaon condensate in neutron star matter

    CERN Document Server

    Kubis, S

    2004-01-01

    The beta equilibrated dense matter with kaon condensate is analyzed with respect to extended stability conditions including charge fluctuations. This kind of the diffusive instability, appeared to be common property in the kaon condensation case. Results for three different nuclear models are presented.

  11. Effective Mass of Kaon in Asymmetrici Nuclear Matter

    Institute of Scientific and Technical Information of China (English)

    LiXiguo; GaoYuan; LiuZiyu; ZuoWei

    2003-01-01

    The properties of kaon at very high baryon density has been a fascinating subject since 1986. Of particular importance is the modification of effective mass of antikaon in-medium. This is expected to not only help us to understander the chiral symmetry restoration but also effect the composition and structure of neutron star.. The modification of kaon and antikaon mass in medium might be a new mechanism of production at energies below the threshold. Based on the mean-field approximation to the effective SU(3)L×SU(3)n chiral Lagrangian, the kaon and anti kaon mass in medium, defined as the energy of a kaon (or antikaon) with zero three momentum,are then given by[1

  12. Orbit error correction on the high energy beam transport line at the KHIMA accelerator system

    Science.gov (United States)

    Park, Chawon; Yim, Heejoong; Hahn, Garam; An, Dong Hyun

    2016-09-01

    For the purpose of treatment of various cancers and medical research, a synchrotron based medical machine has been developed under the Korea Heavy Ion Medical Accelerator (KHIMA) project and is scheduled for use to treat patient at the beginning of 2018. The KHIMA synchrotron is designed to accelerate and extract carbon ion (proton) beams with various energies from 110 to 430 MeV/u (60 to 230 MeV). Studies on the lattice design and beam optics for the High Energy Beam Transport (HEBT) line at the KHIMA accelerator system have been carried out using the WinAgile and the MAD-X codes. Because magnetic field errors and misalignments introduce deviations from the design parameters, these error sources should be treated explicitly, and the sensitivity of the machine's lattice to different individual error sources should be considered. Various types of errors, both static and dynamic, have been taken into account and have been consequentially corrected with a dedicated correction algorithm by using the MAD-X program. Based on the error analysis, the optimized correction setup is decided, and the specifications for the correcting magnets of the HEBT lines are determined.

  13. Composite cone-beam filtered backprojection algorithm based on nutating line

    Institute of Scientific and Technical Information of China (English)

    WANG Yu; OU Zong-ying; SU Tie-ming; WANG Feng

    2006-01-01

    The FDK algorithm is the most popular cone beam algorithm in the medical and industrial imaging field.Due to data insufficiency acquired from a circular trajectory,the images reconstructed by the FDK algorithm suffer from the intensity droping with increasing cone angle.To overcome the drawback,a modified FDK algorithm is presented by convert the 1D ramp filtering direction from along the horizontal lines to along the nutating lines based on the result of Turbell.Unlike Turbell's method,there is no need for our algorithm to rebin the cone-beam data into 3D parallel-beam data before reconstructing.Moreover pre-weighting of the projection data is corrected by compensating for the cone angle effect.In addition,another correction term derived from the result of Hu is also induced into our algorithm.The simulation experiments demonstrate that the final algorithm can suppress the intensity drop associated with the FDK algorithm.

  14. The Kaon Bag Parameter at Physical Mass

    CERN Document Server

    Frison, Julien; Christ, Norman H; Garron, Nicolas; Mawhinney, Robert; Sachrajda, Chris T; Yin, Hantao

    2013-01-01

    We present preliminary results for the calculation of the Kaon Bag parameter $B_K$ in $N_f=2+1$ lattice QCD, using M\\"obius Domain Wall Fermion ensembles generated by the RBC-UKQCD collaboration. This computation is done directly at physical meson masses, so that we do not have to rely on chiral perturbation theory or any other mass extrapolation. In parallel, the four-quark operator is renormalised through the Rome-Southampton technique. Finally, we compare our value with previous results and draw some conclusions about the remaining dominant contributions in our error budget.

  15. Kaon condensation and multi-strange matter

    Science.gov (United States)

    Gazda, D.; Friedman, E.; Gal, A.; Mareš, J.

    2010-04-01

    We report on dynamical calculations of multi- K¯ hypernuclei, which were performed by adding K¯ mesons to particle-stable configurations of nucleons, Λ and Ξ hyperons. The K¯ separation energy as well as the baryonic densities saturate with the number of antikaons. We demonstrate that the saturation is a robust feature of multi- K¯ hypernuclei. Because the K¯ separation energy B does not exceed 200 MeV, we conclude that kaon condensation is unlikely to occur in finite strong-interaction self-bound {N,Λ,Ξ} strange hadronic systems.

  16. The external proton beam lines and the splitter systems of the CERN SPS

    CERN Document Server

    Evans, Lyndon R; Ijspeert, Albert; de Raad, Bastiaan; Siegel, N; Weisse, E

    1977-01-01

    The exploitation of the CERN Super Proton Synchrotron (SPS) is based on two experimental areas, the West Area and the North Area. The West Area consists of the West Experimental Hall, fed by a slow ejected proton beam of 200 GeV/c maximum momentum and a Neutrino Facility which is fed by protons of 400 GeV/c. Several important detectors are installed in the West Area, the Omega spectrometer, the Big European Bubble Chamber and the heavy liquid bubble chamber Gargamelle. The North Area has been built for physics at 400 GeV/c. At present it consists of two experimental halls, a large multipurpose hall and a smaller hall dedicated to muon physics. The protons are extracted from the SPS in two of the six long straight sections (LSS) and are transported from the underground machine through a system of tunnels to the external targets. Both the beam lines to the West and North Area contain beam splitting stations which divide the slow extracted proton beam into three branches. (0 refs).

  17. The IFUSP microtron accelerator beam transport line; Linha de transporte de feixe do acelerador microtron do IFUSP

    Energy Technology Data Exchange (ETDEWEB)

    Rios, Paulo Beolchi

    2002-07-01

    In this work, the electron optical project of the IFUSP microtron beam transport line is presented, including the operational values for the parameters of the dipolar and quadrupolar electromagnets, as well as their location along the beam line. Analytical calculations and computer simulations were performed to obtain these results, and a programming tool was developed in order to analyze the beam parameters and to help studying racetrack microtrons. The electron optical simulations were split into two different study cases: the microtron booster, and the transfer line. In the first case, it was determined the main operational parameters of a microtron working far from its usual stability conditions. In the latter, it was done the basic design of the linking line between the booster and main (not yet built) microtrons, and between them and the experimental hall, with a total path length of approximately 32 m including large horizontal and vertical deflections with variable beam energy. (author)

  18. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.

    Science.gov (United States)

    Harty, P D; Lye, J E; Ramanathan, G; Butler, D J; Hall, C J; Stevenson, A W; Johnston, P N

    2014-05-01

    The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. The good agreement of

  19. Target and orbit feedback simulations of a muSR beam line at BNL

    Energy Technology Data Exchange (ETDEWEB)

    MacKay, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pile, P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-07-28

    Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ+ should be about 40 kHz/mm2. In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

  20. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  1. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  2. Design of a two-ion-source (2-IS) beam transport line for the production of multi charged radioactive ion beams

    CERN Document Server

    Banerjee, V; Bandyopadhyay, A; Chattopadhyay, S; Polley, A; Nakagawa, T; Kamigaito, O; Goto, A; Yano, Y

    2000-01-01

    A 'two-ion-source' beam transport line between a surface ionization source and a 6.4 GHz on-line Electron Cyclotron Resonance Ion Source (ECRIS) for the production of multi-charged radioactive ions has been designed. The 1 sup + ions from the surface ionization source are decelerated and focused onto the ECRIS plasma so that they can be efficiently trapped there and further ionized to charge state q>1 sup +. A scheme for stepwise and gradual deceleration of the 1 sup + ion beam consisting of a multi-electrode decelerator and a tuning electrode placed before the ECRIS has been optimized. The beam dynamics calculations show that the 1 sup + beam decelerated to energies of 20-50 eV could be focused to a spot size smaller than the radial dimensions of the ECR plasma zone.

  3. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    Energy Technology Data Exchange (ETDEWEB)

    Huikari, J. E-mail: jussi.huikari@phys.jyu.fi; Dendooven, P.; Jokinen, A.; Nieminen, A.; Penttilae, H.; Peraejaervi, K.; Popov, A.; Rinta-Antila, S.; Aeystoe, J

    2004-08-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on {alpha}-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporation reactions are introduced. The present study investigated different schemes for ion extraction from the gas cell. The addition of an extra ring electrode between the traditional skimmer electrode and the exit hole led to transmission independent of the primary beam intensity as opposed to strong intensity dependence observed earlier with the plain skimmer only. Furthermore, the mass resolving power of the IGISOL mass separator was increased to 1100 as compared to 250 with the skimmer system when using the RF-sextupole for the extraction from the heavy-ion ion guide. As a new method, the possibility to increase the ion guide efficiency by injecting electrons into the stopping volume is introduced. The efficiency of the electron emitter ion guide was a factor of ten higher in off-line conditions. Also, the influence of the buffer gas purity on the ion survival is discussed.

  4. Development and construction of a neutron beam line for accelerator-based boron neutron capture synovectomy.

    Science.gov (United States)

    Gierga, D P; Yanch, J C; Shefer, R E

    2000-01-01

    A potential application of the 10B(n, alpha)7Li nuclear reaction for the treatment of rheumatoid arthritis, termed Boron Neutron Capture Synovectomy (BNCS), is under investigation. In an arthritic joint, the synovial lining becomes inflamed and is a source of great pain and discomfort for the afflicted patient. The goal of BNCS is to ablate the synovium, thereby eliminating the symptoms of the arthritis. A BNCS treatment would consist of an intra-articular injection of boron followed by neutron irradiation of the joint. Monte Carlo radiation transport calculations have been used to develop an accelerator-based epithermal neutron beam line for BNCS treatments. The model includes a moderator/reflector assembly, neutron producing target, target cooling system, and arthritic joint phantom. Single and parallel opposed beam irradiations have been modeled for the human knee, human finger, and rabbit knee joints. Additional reflectors, placed to the side and back of the joint, have been added to the model and have been shown to improve treatment times and skin doses by about a factor of 2. Several neutron-producing charged particle reactions have been examined for BNCS, including the 9Be(p,n) reaction at proton energies of 4 and 3.7 MeV, the 9Be(d,n) reaction at deuteron energies of 1.5 and 2.6 MeV, and the 7Li(p,n) reaction at a proton energy of 2.5 MeV. For an accelerator beam current of 1 mA and synovial boron uptake of 1000 ppm, the time to deliver a therapy dose of 10,000 RBEcGy ranges from 3 to 48 min, depending on the treated joint and the neutron producing charged particle reaction. The whole-body effective dose that a human would incur during a knee treatment has been estimated to be 3.6 rem or 0.75 rem, for 1000 ppm or 19,000 ppm synovial boron uptake, respectively, although the shielding configuration has not yet been optimized. The Monte Carlo design process culminated in the construction, installation, and testing of a dedicated BNCS beam line on the high

  5. New Physics Signatures in Kaon Decays

    CERN Document Server

    Blanke, Monika

    2013-01-01

    Kaon physics provides a unique opportunity to identify new flavour and CP violating interactions beyond the Standard Model (SM). In the SM, implied by the hierarchical structure of the CKM matrix and the GIM mechanism, flavour changing neutral current processes are most strongly suppressed in the kaon sector while the suppression is much less effective in the B meson systems. Thus their theoretical cleanness makes rare K decays, in particular the K -> pi nu anti-nu system, extremely well suited to look for deviations from their tiny SM values. Despite the increasingly stringent constraints on new physics from direct search experiments as well as indirect searches in B meson decays, large enhancements of both K^+ -> pi^+ nu anti-nu and K_L -> pi^0 nu anti-nu are still possible, and deviations from the SM could be observed even for a multi-TeV new physics scale. In addition the correlation betweeen the charged and neutral K -> pi nu anti-nu modes provides insight on the new physics operator structure in K^0 - a...

  6. Millimeter-Wave Line Ratios and Sub-beam Volume Density Distributions

    CERN Document Server

    Leroy, Adam K; Schruba, Andreas; Bigiel, Frank; Kruijssen, J M Diederik; Kepley, Amanda; Blanc, Guillermo A; Bolatto, Alberto D; Cormier, Diane; Gallagher, Molly; Hughes, Annie; Jimenez-Donaire, Maria J; Rosolowsky, Erik; Schinnerer, Eva

    2016-01-01

    We explore the use of mm-wave emission line ratios to trace molecular gas density when observations integrate over a wide range of volume densities within a single telescope beam. For observations targeting external galaxies, this case is unavoidable. Using a framework similar to that of Krumholz and Thompson (2007), we model emission for a set of common extragalactic lines from lognormal and power law density distributions. We consider the median density of gas producing emission and the ability to predict density variations from observed line ratios. We emphasize line ratio variations, because these do not require knowing the absolute abundance of our tracers. Patterns of line ratio variations have the prospect to illuminate the high-end shape of the density distribution, and to capture changes in the dense gas fraction and median volume density. Our results with and without a high density power law tail differ appreciably; we highlight better knowledge of the PDF shape as an important area. We also show th...

  7. 100 years of elementary particles [Beam Line, vol. 27, issue 1, Spring 1997

    Energy Technology Data Exchange (ETDEWEB)

    Pais, Abraham; Weinberg, Steven; Quigg, Chris; Riordan, Michael; Panofsky, Wolfgang K.H.; Trimble, Virginia

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  8. Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    CERN Document Server

    Pan, R; Lefevre, T; Gillepsie, WA; CERN. Geneva. ATS Department

    2015-01-01

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding(EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  9. 100 years of Elementary Particles [Beam Line, vol. 27, issue 1, Spring 1997

    Science.gov (United States)

    Pais, Abraham; Weinberg, Steven; Quigg, Chris; Riordan, Michael; Panofsky, Wolfgang K. H.; Trimble, Virginia

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  10. Design and construction of UVSOR-BL4A2 beam line for nano-structure processing

    CERN Document Server

    Takezoe, N; Tanaka, T; Kurosawa, K; Nonogaki, Y; Noda, H; Mekaru, H; Urisu, T

    2001-01-01

    We have designed and constructed a new beam line BL4A2 at UVSOR mainly for nano-structure fabrication based on synchrotron radiation stimulated surface photochemical reactions. In order to obtain high-photon flux, we use white ray beam focused with only one mirror. The beam line is connected with ultra-high vacuum scanning tunneling microscope for in-situ atomic scale observations, low energy electron diffraction and Auger electron spectroscope for surface crystal structure characterization, and photo-stimulated surface reaction chamber. In order to monitor the optical properties with atomic scale, a near field optical microscope is planned to be installed.

  11. Extracting the Kaon Collins function from $e^+e^-$ hadron pair production data

    CERN Document Server

    Anselmino, M; D'Alesio, U; Hernandez, J O Gonzalez; Melis, S; Murgia, F; Prokudin, A

    2015-01-01

    The latest data released by the BaBar Collaboration on azimuthal correlations measured for pion-kaon and kaon-kaon pairs produced in $e^+e^-$ annihilations allow, for the first time, a direct extraction of the kaon Collins functions. These functions are then used to compute the kaon Collins asymmetries in Semi Inclusive Deep Inelastic Scattering processes, which result in good agreement with the measurements performed by the HERMES and COMPASS Collaborations.

  12. The charge breeder beam line for the selective production of exotic species project at INFN-Legnaro National Laboratories

    Science.gov (United States)

    Galatà, A.; Comunian, M.; Maggiore, M.; Manzolaro, M.; Angot, J.; Lamy, T.

    2014-02-01

    SPES (Selective Production of Exotic Species) is an INFN (Istituto Nazionale di Fisica Nucleare) project with the aim at producing and post-accelerating exotic beams to perform forefront research in nuclear physics. To allow post-acceleration of the radioactive ions, an ECR-based Charge Breeder (CB) developed on the basis of the Phoenix booster was chosen. The design of the complete beam line for the SPES-CB will be described: a system for stable 1+ beams production was included; special attention was paid to the medium resolution mass spectrometer after the CB to limit possible superposition of the exotic beams with the impurities present in the ECR plasma.

  13. An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles

    CERN Document Server

    Nirkko, M; Ereditato, A; Kreslo, I; Scampoli, P; Weber, M

    2012-01-01

    A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.

  14. Design of the extraction arc for the 2{sup nd} beam line of the free-electron laser FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, Matthias

    2014-01-15

    In this thesis, I deal with the design of the extraction arc for the second beam line of FLASH, an FEL (Free-Electron Laser) user facility at DESY Hamburg. Both beam lines will use the same linear accelerator and their separation will take place behind the last accelerating module. I present the constraints for the extraction arc given by the beam line layout of the existing machine, by the building environment of the new beam line and in particular, by coherent synchrotron radiation (CSR). The impact from CSR is presented, and I show how to mitigate these effects and what that means for the beam line design. The optimization of the extraction arc was done applying the downhill simplex algorithm which is presented, first in its basic form to explain the operation principle and then in a more advanced version as used in the applied program. I introduce in this thesis the final layout of the extraction arc including the following matching section. This layout fulfills all given constraints and can provide the required electron beam quality for FEL operation. In order to prove this, I present start-to-end simulations for different bunch charges and for two different wavelengths.

  15. Measurement of the charged kaon lifetime with the KLOE detector

    CERN Document Server

    Ambrosino, F; Antonelli, M; Archilli, F; Bacci, C; Beltrame, P; Bencivenni, G; Bertolucci, S; Bini, C; Bloise, C; Bocchetta, S; Bossi, F; Branchini, P; Caloi, R; Campana, P; Capon, G; Capussela, T; Ceradini, F; Chi, S; Chiefari, G; Ciambrone, P; De Lucia, E; De Santis, A; De Simone, P; De Zorzi, G; Denig, A; Di Domenico, A; Di Donato, C; Di Micco, B; Doria, A; Dreucci, M; Felici, G; Ferrari, A; Ferrer, M L; Fiore, S; Forti, C; Franzini, P; Gatti, C; Gauzzi, P; Giovannella, S; Gorini, E; Graziani, E; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Leone, D; Martini, M; Massarotti, P; Mei, W; Meola, S; Miscetti, S; Moulson, M; Müller, S; Murtas, F; Napolitano, M; Nguyen, F; Palutan, M; Pasqualucci, E; Passeri, A; Patera, V; Perfetto, F; Primavera, M; Santangelo, P; Saracino, G; Sciascia, B; Sciubba, A; Sibidanov, A; Spadaro, T; Testa, M; Tortora, L; Valente, P; Venanzoni, G; Versaci, R; Xu, G

    2008-01-01

    We have measured the charged kaon lifetime using a sample of 15 \\times 10^6 tagged kaon decays. Charged kaons were produced in pairs at the DA\\PhiNE \\phi-factory, e^+e^- \\to \\phi \\to K^+ K^-. The decay of a K^+ was tagged by the production of a K^- and viceversa. The lifetime was obtained, for both charges, from independent measurements of the decay time and decay lenght distributions. From fits to the four distributions we find \\tau = (12.347\\pm0.030) ns.

  16. On-line Scanned Probe Microscopy Transparently Integrated with DualBeam SEM/FIB Systems

    Science.gov (United States)

    Ignatov, Andrey; Komissar, Anatoly; Lewis, Aaron

    2013-03-01

    A multifunctional scanning probe microscope (SPM) will be described that transparently integrates with a DualBeam SEM/FIB System. This is done without perturbing any of the capabilities of the Dual Beam in terms of detectors, gas injectors, analyzers etc while allowing for a completely exposed probe tip to be imaged online even with immersion objectives at working distances as short as 4 mm. In addition, the completely free motion of the rotation axis of the stage is maintained with the probe tip at the eucentric point, this makes it possible to orient the sample in any direction on any structure The X and Y scan range of the atomic force microscopic (AFM) imaging achieves 35 microns with rough motion over 10 millimeters. This permits the SPM to tilt into position perpendicular to the SEM or FIB or under an angle for rapid and accurate placement of the probe tip at or on structures such as biopolymeric materials that are nanometric in X, Y and Z extent. Thus, not only can a structure's nanometric height be accurately profiled but this can be accomplished with the on-line excellence of SEM for X, Y metrology. Furthermore, electron and ion beam sensitive samples can be imaged and characterized by AFM at high resolution.

  17. Orbit Error Correction on the High Energy Beam Transport Line at the KHIMA Accelerator System

    CERN Document Server

    Park, Chawon; Hahn, Garam; An, Dong Hyun

    2016-01-01

    For the purpose of treatment of various cancer and medical research, the synchrotron based medical machine under the Korea Heavy Ion Medical Accelerator (KHIMA) project have been conducted and is going to treat the patient at the beginning of 2018. The KHIMA synchrotron is designed to accelerate and extract the carbon ion (proton) beam with various energy range, 110 up to 430 MeV/u (60 up to 230 MeV). A lattice design and beam optics studies for the High Energy Beam Transport (HEBT) line at the KHIMA accelerator system have been carried out with WinAgile and the MAD-X codes. Because the magnetic eld errors and the mis-alignments introduce to the deviations from the design parameters, these error sources should be treated explicitly and the sensitivity of the machine's lattice to di erent individual error sources is considered. Various types of errors which are static and dynamic one have been taken into account and have been consequentially corrected with a dedicated correction algorithm by using the MAD-X pr...

  18. Beryllium window and acoustic delay line design for x-ray lithography beam lines at the University of Wisconsin Center for X-ray Lithography

    Science.gov (United States)

    Brodsky, E. L.; Hamilton, W.; Wells, G.; Cerrina, F.; Corradini, M.

    1992-01-01

    X-ray lithography systems require sample chambers that can perform exposures in helium gas at atmospheric pressure. The interface between the experimental chamber and the beamline is critical for x-ray lithography and the storage ring. It must allow a high x-ray flux throughput while providing a vacuum barrier so that helium gas does not leak into the beam line and the storage ring. The beam line must also be designed to have protection in the case that a window does fail in order to minimize adverse effects to the ring and other systems. The details of the design for the vacuum system used on beam lines for the Center for X-ray Lithography at the University of Wisconsin Synchrotron Radiation Center 1-GeV electron storage ring are reported. Curved beryllium windows with a 1×5-cm2 aperture and 13 μm thick that have a leak rate less than 10-10 Torr l/s have been successfully used at the experimental chamber beam-line interface. This thin flat beryllium foil is mounted in a curved housing with a wire seal to minimize helium leakage. The window assembly is designed and has been tested to withstand substantial overpressure before failure. If the beryllium window does fail, the beamline has an acoustic delay line that is designed to delay the incoming shock wave of helium gas so that a fast valve at the end of the beam line will close and minimize leakage of helium into the storage ring. The acoustic delay line is designed with baffles to slow the shock front and a secondary thin window to protect against molecular diffusion into the storage ring. The acoustic delay line has been tested to determine the effect of baffle design on delay of the shock wave. A theoretical model that provides a good description of the acoustic delay has also been developed.

  19. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan

    2016-09-01

    We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200 μ m , for two final bunch charges: 1 05 electrons (16 fC) and 1 06 electrons (160 fC). Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of Lc ,x/σx=0.27 nm /μ m was obtained for a final bunch charge of 1 05 electrons and final bunch length of σt≈100 fs . For a final charge of 1 06 electrons the cryogun produces Lc ,x/σx≈0.1 nm /μ m for σt≈100 - 200 fs and σx≥50 μ m . These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  20. Transfer of polarized 3He ions in the AtR beam transfer line

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas N.; MacKay, W.W.; Meot, F.; Roser, T.; Trbojevic, D.

    2012-05-20

    In addition to collisions of electrons with various unpolarized ion species as well as polarized protons, the proposed electron-hadron collider (eRHIC) will facilitate the collisions of electrons with polarized {sup 3}He ions. The AGS is the last acceleration stage, before injection into one of the RHIC's collider ring for final acceleration. The AtR (AGS to RHIC) transfer line will be utilized to transport the polarized {sup 3}He ions from AGS into one of the RHIC's collider rings. Some of the peculiarities of the AtR line's layout (simultaneous horizontal and vertical bends) may degrade the matching of the stable spin direction of the AtR line with that of RHIC's. In this paper we discuss possible simple modifications of the AtR line to accomplish a perfect matching of the stable spin direction of the injected {sup 3}He beam with the stable spin direction at the injection point of RHIC.

  1. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    Science.gov (United States)

    Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Raffaele, L.; Russo, G.; Guatelli, S.; Pia, M. G.

    2006-01-01

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility.

  2. Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, D.; Leitner, D., E-mail: leitnerd@nscl.msu.edu; Cole, D.; Machicoane, G.; Tobos, L. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2014-02-15

    In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

  3. IDENTIFIKASI PROFIL DASAR LAUT MENGGUNAKAN INSTRUMEN SIDE SCAN SONAR DENGAN METODE BEAM PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY

    Directory of Open Access Journals (Sweden)

    Muhammad Zainuddin Lubis

    2017-05-01

    Full Text Available Laut Punggur merupakan laut yang terletak di Batam, Kepulauan Riau yang mempunyai beragam habitat objek,dan bentuk struktur bawah laut yang memiliki dinamika laut yang sangat tinggi. Side scan sonar (SSS merupakan instrumen pengembangan sistem sonar yang mampu menunjukkan dalam gambar dua dimensional permukaan dasar laut dengan kondisi kontur, topografi, dan target secara bersamaan. Metode Beam Pattern Discrete-Equi-Spaced Unshaded Line Array digunakan untuk menghitung beam pattern dua dimensi yang tergantung pada sudut dari gelombang suara yang masuk dari sumbu array yang diterima tergantung pada sudut di mana sinar suara pada array. Penelitian ini dilakukan pada Desember 2016 di laut Punggur,Batam, Kepulauan Riau-Indonesia, dengan koordinat 104 ° 08,7102 E dan 1° 03,2448 N sampai 1 ° 03.3977 N dan 104 ° 08,8133 E, menggunakan instrumen Side Scan Sonar C-Max CM2 Tow fish dengan frekuensi 325 kHz. Hasil yang diperoleh dari perekaman terdapat 7 target, dan Beam pattern dari metode Beam Discrete-Equi-Spaced Unshaded Line Array target 4 memiliki nilai tertinggi pada directivity Pattern yaitu 21.08 dB. Hasil model beam pattern ini memiliki nilai pusat pada incidence angle (o terhadap Directivity pattern (dB tidak berada di nilai 0 ataupun pada pusat beam pattern yang dihasilkan pada target 6 dengan nilai incident angle -1.5 o dan 1.5o mengalami penurunan hingga -40 dB. Karakteristik sedimen dasar perairan di laut punggur ditemukan lebih banyak pasir. Hasil metode Beam Discrete-Equi-Spaced Unshaded Line Array ditemukan bangkai kapal tenggelam.Kata Kunci: Side Scan Sonar, Beam Pattern Discrete-Equi-Spaced Unshaded Line Array, Incidence angle, Directivity pattern IDENTIFICATION OF SEABED PROFILE USING SIDE SCAN SONAR INSTRUMENT WITH PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY METHODRiau Islands is an island that has a variety of habitat objects, and forms of submarine structures that have a very high ocean dynamics, Punggur Sea is the sea

  4. Cosmology tests in rare kaon decays

    Directory of Open Access Journals (Sweden)

    Duk Viacheslav

    2016-01-01

    Full Text Available The Standard Model (SM of particle physics is an extremely successful theory that effectively describes strong and electroweak interactions up to the energies presently accessible. Still, the SM does not explain the observed parameters of neutrino oscillations, baryon asymmetry of the Universe and Dark Matter (DM, and contains a fine-tuning of 16 orders of magnitude (the gauge hierarchy problem. Various New Physics (NP models beyond the SM have been developed in order to address the above limitations. This paper concentrates on several models related to cosmology and their tests in rare kaon decays. In particular, recent NA48/2 results on the search for heavy neutrinos, light in-flatons and dark photons are presented. Prospects for the ongoing NA62 experiment are discussed.

  5. Pion and Kaon Electromagnetic Form Factors

    CERN Document Server

    Bijnens, J; Bijnens, Johan; Talavera, Pere

    2002-01-01

    We study the electromagnetic form factor of the pion and kaons at low-energies with the use of Chiral Perturbation Theory. The analysis is performed within the three flavour framework and at next-to-next-to-leading order. We explain carefully all the relevant consistency checks on the expressions, present full analytical results for the pion form factor and describe all the assumptions in the analysis. From the phenomenological point of view we make use of our expression and the available data to obtain the charge radius of the pion obtaining $_V^\\pi=(0.452+-0.013) fm^2$, as well as the low-energy constant $L_9^r(m_\\rho)= (5.93+-0.43)10^{-3}$. We also obtain experimental values for 3 combinations of order $p^6$ constants.

  6. Strange Baryonic Matter and Kaon Condensation

    Science.gov (United States)

    Gazda, D.; Friedman, E.; Gal, A.; Mareš, J.

    In this contribution we address the question whether kaon condensation could occur in strongly interacting self-bound strange hadronic matter. In our comprehensive dynamical relativistic mean-field (RMF) calculations of nuclear and hypernuclear systems containing several antikaons we found saturation of bar K separation energy as well as the associated nuclear and bar K density distributions upon increasing the number of bar K mesons. The saturation pattern was found to be a universal feature of these multi-strangeness configurations. Since in all cases the bar K separation energy does not exceed 200 MeV, we conclude that bar K mesons do not provide the physical "strangeness" degrees of freedom for self-bound strange hadronic matter.

  7. Multi-kaonic Hypernuclei and Kaon Condensation

    Science.gov (United States)

    Gazda, D.; Friedman, E.; Gal, A.; Mareš, J.

    2011-09-01

    This contribution reports on dynamical, self-consistent calculations of multi-bar K hypernuclei, which were performed by adding antikaons to particle-stable nuclear configurations of nucleons, Λ and Ξ hyperons. Our results show a robust pattern of saturation of the bar K separation energy Bbar K as a function of the number of bar K mesons, with Bbar K bounded from above by 200 MeV. The associated baryon densities saturate at values 2-3 times nuclear-matter density. The main reason for saturation is the repulsion induced by the vector meson fields between bar K mesons, similarly to what was found for multi-bar K nuclei. The calculations confirm that strangeness in finite strong-interaction self-bound systems is realized through hyperons, with no room for kaon condensation.

  8. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    Science.gov (United States)

    Liu, S.; Bogard, F.; Cornebise, P.; Faus-Golfe, A.; Fuster-Martínez, N.; Griesmayer, E.; Guler, H.; Kubytskyi, V.; Sylvia, C.; Tauchi, T.; Terunuma, N.; Bambade, P.

    2016-10-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of ∼106 has been successfully demonstrated and confirmed for the first time in simultaneous beam core (∼109 electrons) and beam halo (∼103 electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of diamond sensors using an α source, as well as using the electron beams at PHIL, a low energy < 5 MeV photo-injector at LAL, and at ATF2. First beam halo measurement results using the DSv at ATF2 with different beam intensities and vacuum levels are also presented. Such measurements not only allow one to evaluate the different sources of beam halo generation but also to define the requirements for a suitable collimation system to be installed at ATF2, as well as to optimize its performance during future operation.

  9. Current Issues in Kaon Photoelectro-Production off the Nucleon

    CERN Document Server

    Achenbach, Patrick

    2011-01-01

    The electromagnetic kaon production amplitudes associated to Lambda/Sigma hyperons can be described by phenomenological models, most notably by isobar approaches. Experimental data on kaon production have been collected at ELSA, SPring8, GRAAL, LNS Tohoku, and Jefferson Lab in the past, the measurements at Jefferson Lab providing the largest kinematic coverage and statistical significance. However, ambiguities inherent in the models, some data inconsistency in the cross-sections taken at different laboratories, and the problem of missing acceptance in forward direction of the experimental set-ups hinders a reliable extraction of resonance parameters. Predictions for the hypernuclear photo-production cross-section rely on a consistent and comprehensive description of the elementary process at forward kaon angles, where the current strong variation of the models is very unsatisfactory. A number of new experiments are now addressing these issues, among them the charged kaon electro-production programme with the ...

  10. Design and fabrication of soft x-ray photolithography experimental beam line at Beijing National Synchrotron Radiation Laboratory

    Science.gov (United States)

    Zhou, Changxin

    1991-08-01

    The synchrotron radiation (SR) soft x-ray photolithography experimental beam line (3B1 beam line) at Beijing National Synchrotron Radiation Laboratory, was completed and tested in June 1990. A soft x-ray photolithography experiment was successfully completed, and the width of linear etch on a silicon chip by the device with a 3B1 beam line is up to 0.5 micrometers . This SR soft x-ray photolithography experiment was done successfully for the first time in China. This paper describes the design of the beam line and the fabrication of the most important optical element--the cylindrical scanning mirror in the beam line. The 3B1 beam line consists of the shielding light plate with water-cooling, laser simulation light source system, 3-D adjustable scanning mirror, high pass-band filer (beryllium window), acoustic sensor, helium gas chamber, and vacuum system. The main specifications of the 3B1 beam line are as follows: spectral range 0.4-2 nm; horizontal acceptance angle 7.5 mrad; vertical acceptance angle 0.4 mrad; grazing incidence angle 1.5 deg; light spot size 35 nm X 12 nm; vacuum degree of the mirror box 5 X 10-10 torr (static). The cylindrical scanning mirror in grazing incidence is used in the beam line for photolithography to obtain uniform distributed intensity of illumination of the SR source in the vertical direction (Gaussian distribution) and sufficiently concentrated energy. It is made of aluminum alloy LD2 with a supersmooth optical surface. The curvature radius of the cylindrical surface is 527.5 mm; surface figure error is less than (lambda) /10; surface roughness is better than 1 nm RMS, and fold coating on the surface of the mirror under UHV of 109 torr. The laser simulation light source system is used for adjusting the optical system in the beam line instead of the SR source. The cylindrical mirror was polished supersmoothly using Al2O3 ultra micropower grinding material made in TOMAS in Japan on modified traditional machine tools, and surface

  11. Determination of the pion and kaon structure functions

    Energy Technology Data Exchange (ETDEWEB)

    Aitkenhead, W.; Barton, D.S.; Brandenburg, G.W.; Busza, W.; Dobrowolski, T.; Friedman, J.I.; Kendall, H.W.; Lyons, T.; Nelson, B.; Rosenson, L.; Toy, W.; Verdier, R.; Votta, L.; Chiaradia, M.T.; DeMarzo, C.; Favuzzi, C.; Germinario, G.; Guerriero, L.; LaVopa, P.; Maggi, G.; Posa, F.; Selvaggi, G.; Spinelli, P.; Waldner, F.; Brenner, A.E.; Carey, D.C.; Elias, J.E.; Garbincius, P.H.; Mikenberg, G.; Polychronakos, V.A.; Meunier, R.; Cutts, D.; Dulude, R.S.; Lanou, R.E. Jr.; Massimo, J.T.

    1980-07-21

    Quark structure functions have been extracted from low-p/sub T/ inclusive hadron production data for the pion and kaon with use of the recombination model. n/sup ..pi../=1.0 +- 0.1 and n/sup K/=2.5 +- 0.6 is obtained, where n is the leading (1-x) power of the nonstrange--valence-quark distribution. Both the pion and kaon nonstrange--sea-quark functions have napprox. =3.5.

  12. Rare and forbidden kaon decays at the AGS

    Energy Technology Data Exchange (ETDEWEB)

    Kettell, S.

    1997-12-09

    An overview of the Rare Kaon Decay program at the AGS is presented, with particular emphasis on the three major experiments currently running and analyzing data. A brief overview of earlier kaon decay experiments and of the AGs performance improvements is also provided. This review concludes with a discussion of proposed and developing experiments planned to run in the year 2000 and beyond (AGS-2000).

  13. The Electromagnetic Mass Differences of Pions and Kaons

    CERN Document Server

    Donoghue, J F; Donoghue, John F.; Perez, Antonio F.

    1997-01-01

    We use the Cottingham method to calculate the pion and kaon electromagnetic mass differences with as few model dependent inputs as possible. The constraints of chiral symmetry at low energy, QCD at high energy and experimental data in between are used in the dispersion relation. We find excellent agreement with experiment for the pion mass difference. The kaon mass difference exhibits a strong violation of the lowest order prediction of Dashen's theorem, in qualitative agreement with several other recent calculations.

  14. Collective Flow of A Hyperons within Covariant Kaon Dynamics

    Institute of Scientific and Technical Information of China (English)

    XING Yong-Zhong; ZHU Yu-Lan; WANG Yan-Yan; ZHENG Yu-Ming

    2011-01-01

    @@ The collective flow of ∧ hyperons produced in association with positively charged kaon mesons in nuclear reactions at SIS energies is studied using the quantum molecular dynamics(QMD)model within covariant kaon dynamics Our calculation indicates that both the directed and differential directed flows of ∧s are almost in agreement with the experimental data.This suggest that the covariant kaon dynamics based on the chiral mean field approximation can not only explain the collective flow of kaon mesons,but also give reasonable results for the collective flow of ∧ hyperons at SIS energies.The final-state interaction of ∧ hyperons with dense nuclear matter enhances their directed flow and improves the agreement of their differential directed flow with the experimental data.The influence of the interaction on the ∧ collective flow is more appreciable at large rapidity or transverse momentum region.%The collective How of A hyperons produced in association with positively charged kaon mesons in nuclear reactions at SIS energies is studied using the quantum molecular dynamics (QMD) model within covariant kaon dynamics. Our calculation indicates that both the directed and differential directed Sows of As are almost in agreement with the experimental data. This suggest that the covariant kaon dynamics based on the chiral mean Geld approximation can not only explain the collective flow of kaon mesons, but also give reasonable results for the collective How of A hyperons at SIS energies. The Hnal-state interaction of A hyperons with dense nuclear matter enhances their directed How and improves the agreement of their differential directed How with the experimental data. The influence of the interaction on the A collective How is more appreciable at iarge rapidity or transverse momentum region.

  15. Kaon-nucleon scattering lengths from kaonic deuterium experiments revisited

    CERN Document Server

    Döring, M

    2011-01-01

    We analyse the impact of the recent measurement of kaonic hydrogen X rays by the SIDDHARTA collaboration on the allowed ranges for the kaon-deuteron scattering length in the framework of non-relativistic effective field theory. Based on data from KN scattering only, we predict the kaon-deuteron scattering length A_Kd= (-1.46 + i 1.08) fm, with an estimated uncertainty of about 25% in both the real and the imaginary part.

  16. Kaon Thresholds and Two-Flavor Chiral Expansions for Hyperons

    Energy Technology Data Exchange (ETDEWEB)

    Fu-Jiun Jiang, Brian C. Tiburzi, Andre Walker-Loud

    2011-01-01

    Two-flavor chiral expansions provide a useful perturbative framework to study hadron properties. Such expansions should exhibit marked improvement over the conventional three-flavor chiral expansion. Although one can theoretically formulate two-flavor theories for the various hyperon multiplets, the nearness of kaon thresholds can seriously undermine the effectiveness of the perturbative expansion in practice. We investigate the importance of virtual kaon thresholds on hyperon properties, specifically their masses and isovector axial charges. Using a three-flavor expansion that includes SU(3) breaking effects, we uncover the underlying expansion parameter governing the description of virtual kaon thresholds. For spin-half hyperons, this expansion parameter is quite small. Consequently virtual kaon contributions are well described in the two-flavor theory by terms analytic in the pion mass-squared. For spin three-half hyperons, however, one is closer to the kaon production threshold, and the expansion parameter is not as small. Breakdown of SU(2) chiral perturbation theory is shown to arise from a pole in the expansion parameter associated with the kaon threshold. Estimating higher-order corrections to the expansion parameter is necessary to ascertain whether the two-flavor theory of spin three-half hyperons remains perturbative. We find that, despite higher-order corrections, there is a useful perturbative expansion for the masses and isovector axial charges of both spin-half and spin three-half hyperons.

  17. The Nexawatt: A Strategy for Exawatt Peak Power Lasers Based on NIF and NIF-like Beam Lines

    Science.gov (United States)

    Barty, C. P. J.

    2016-05-01

    An exawatt-scale, short-pulse amplification architecture based upon a novel pulse compressor arrangement and amplification of long-duration chirped beam pulses is described. This architecture is capable of extracting the full, stored energy of a NIF or NIF-like beam line and in doing so produce from one beam line a near-diffraction-limited, laser pulse whose peak power would exceed 0.2 EW. The architecture is well suited to either low-f-number focusing or to multi-beam, dipole focusing concepts that in principle enable focused intensities in the range of 1026 W/cm2 or 5 orders of magnitude beyond that possible from present PW systems based on chirped pulse amplification.

  18. Multiobjective optimization design of an rf gun based electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan; Maxson, Jared

    2017-03-01

    Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100 MV /m 1.6-cell normal conducting rf (NCRF) gun, as well as a nine-cell 2 π /3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 1 06 electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 1 06 electrons and final beam sizes of σx≥25 μ m and σt≈5 fs , we found a relative coherence length of Lc ,x/σx≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2 nm /μ m , respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 1 05 electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92 nm /μ m for final bunch lengths of 5, 30 and 100 fs, respectively.

  19. An improved elliptic guide concept for a homogeneous neutron beam without direct line of sight

    CERN Document Server

    Zendler, C; Lieutenant, K

    2014-01-01

    Ballistic neutron guides are efficient for neutron transport over long distances, and in particular elliptically shaped guides have received much attention lately. However, elliptic neutron guides generally deliver an inhomogeneous divergence distribution when used with a small source, and do not allow kinks or curvature to avoid a direct view from source to sample. In this article, a kinked double-elliptic solution is found for neutron transport to a small sample from a small (virtual) source, as given e.g. for instruments using a pinhole beam extraction with a focusing feeder. A guide consisting of two elliptical parts connected by a linear kinked section is shown by VITESS simulations to deliver a high brilliance transfer as well as a homogeneous divergence distribution while avoiding direct line of sight to the source. It performs better than a recently proposed ellipse-parabola hybrid when used in a ballistic context with a kinked or curved central part. Another recently proposed solution, an analyticall...

  20. Detector Response and Beam Line Transmission Measurements with Far-Infrared Radiation

    CERN Document Server

    Grimm, O; Fröhlich, L

    2005-01-01

    Various activities at the TTF linear accelerator at DESY, Hamburg, that drives the VUV-FEL are geared towards measuring the longitudinal charge distribution of electron bunches with coherent far-infrared radiation. Examples are beam lines transporting synchrotron or transition radiation to interferometers mounted inside or outside the tunnel, and studies of single-shot grating spectrometers. All such approaches require a good understanding of the radiation generation and transport mechanism and of the detector characteristics to extract useful information on the charge distribution. Simulations and measurements of the expected transverse intensity distribution and polarization of synchrotron radiation emitted at the first bunch compressor of TTF have been performed. The transverse intensity scanning provided for the first time at DESY a visual image of the footprint of terahertz radiation. Detector response measurements have been performed at the FELIX facility, Netherlands, for wavelengths between 100-160 mi...

  1. Development of a polarized neutron beam line at Algerian research reactors using McStas software

    Science.gov (United States)

    Makhloufi, M.; Salah, H.

    2017-02-01

    Unpolarized instrumentation has long been studied and designed using McStas simulation tool. But, only recently new models were developed for McStas to simulate polarized neutron scattering instruments. In the present contribution, we used McStas software to design a polarized neutron beam line, taking advantage of the available spectrometers reflectometer and diffractometer in Algeria. Both thermal and cold neutron was considered. The polarization was made by two types of supermirrors polarizers FeSi and CoCu provided by the HZB institute. For sake of performance and comparison, the polarizers were characterized and their characteristics reproduced. The simulated instruments are reported. Flipper and electromagnets for guide field are developed. Further developments including analyzers and upgrading of the existing spectrometers are underway.

  2. Compact intra-cavity frequency doubled line beam green laser by a laser diode array pumped

    Science.gov (United States)

    Yan, Boxia; Qi, Yan; Wang, Yanwei

    2016-10-01

    Compact, high power, and low-cost green laser light sources are needed in projection-related applications such as digital cinema, rear-projection television, simulators, and command and control stations. We report a LD array directly pumped intracavity SHG Nd:YVO4/PPMgLN laser without lens or waveguide in this letter. A compact 3.12 W green laser was demonstrated by intra-cavity frequency doubled using a PPMgLN bulk crystal by a 19-emitter LD array pumped(single bar), the conversion efficiency from input LD array was 9.2%. A line-beam output suitable for laser projectors was generated, which has the potential to be scalable to small volumes and low costs for laser projection displays.

  3. Generation of a twin beam at the cesium line and telecom wavelength by cavity phase matching.

    Science.gov (United States)

    Liu, Y H; Xie, Z D; Ling, W; Lv, X J; Zhu, S N

    2011-08-15

    Cavity phase matching has been recently demonstrated as a phase-matching method for efficient nonlinear frequency conversion in a microcavity. Here we extend it to the Type I configuration using a sub-coherent-length optical parametric oscillator consisting of an MgO-doped lithium niobate crystal sheet. It generates a tunable single-longitudinal-mode twin beam, which covers the cesium D2 line of 852.1 nm and the extended band of optical communication. This microcavity is capable of peak output power of 58 kW with a maximum conversion efficiency of 18.5%. Broad applications in the areas of light-atom interaction, spectroscopy, optical telecommunication, and quantum optics can be expected.

  4. High power microwave beam steering based on gyromagnetic nonlinear transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Romanchenko, I. V., E-mail: riv@lfe.hcei.tsc.ru; Rostov, V. V.; Gunin, A. V.; Konev, V. Yu. [Institute of high current electronics SB RAS, Akademichesky 2/3, 634055, Tomsk (Russian Federation)

    2015-06-07

    We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

  5. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Liu, Shan; Cornebise, Patrick; Faus-Golfe, Angeles; Fuster-Martínez, Nuria; Griesmayer, Erich; Guler, Hayg; Kubytskyi, Viacheslav; Sylvia, Christophe; Toshiaki, Tauchi; Terunuma, Nobuhiro; Bambade, Philip

    2015-01-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of $\\sim10^6$ has been successfully demonstrated and confirmed for the first time by simultaneous beam core ($\\sim10^9$ electrons) and beam halo ($\\sim10^3$ electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of the diamond sensors using an $\\alpha$ source as well as using the electron beams at PHIL, a low energy ($< 10$ MeV) photo-injector at LAL, and at ATF2. First beam halo measurement results ...

  6. RAPD and SSR Polymorphisms in Mutant Lines of Transgenic Wheat Mediated by Low Energy Ion Beam

    Institute of Scientific and Technical Information of China (English)

    WANG Tiegu; HUANG Qunce; FENG Weisen

    2007-01-01

    Two types of markers-random amplified polymorphic DNA (RAPD) and simple sequence repeat DNA (SSR)-have been used to characterize the genetic diversity among nine mutant lines of transgenic wheat intermediated by low energy ion beam and their four receptor cultivars. The objectives of this study were to analyze RAPD-based and SSR-based genetic variance among transgenic wheat lines and with their receptors, and to find specific genetic markers of special traits of transgenic wheat lines. 170 RAPD primers were amplified to 733 fragments in all the experimental materials. There were 121 polymorphic fragments out of the 733 fragments with a ratio of polymorphic fragments of 16.5%. 29 SSR primer pairs were amplified to 83 fragments in all the experiment materials. There were 57 polymorphic fragments out of the 83 fragments with a ratio of polymorphic fragments of 68.7%. The dendrograms were prepared based on a genetic distance matrix using the UPGMA (Unweighted Pair-group Method with Arithmetic averaging) algorithm, which corresponded well to the results of the wheat pedigree analysis and separated the 13 genotypes into four groups. Association analysis between RAPD and SSR markers with the special traits of transgenic wheat mutant lines discovered that three RAPD markers, si, opt-16, and fl4, were significantly associated with the muticate trait, while three SSR markers, Rht8 (Xgwm261), Rht-Blb, and Rht-Dlb, highly associated with the dwarf trait. These markers will be useful for marker-assistant breeding and can be used as candidate markers for further gene mapping and cloning.

  7. Radiation-hard Beam Position Detector for Use in the Accelerator Dump Lines

    CERN Document Server

    Degtiarenko, Pavel; Popov, Vladimir

    2005-01-01

    Proper transport of the electron beam with over 0.5MW of power to the beam dump is a prerequisite for operations at Jefferson Lab. Operations has relied on imaging the beam on a beam viewer located at the entrance to the beam dump. The large beam size at the dump entrance, due to beam scattering in the experimental target, sometimes results in no observable image on the view-screen. Chemical vapor deposited silicon carbide (CVD) material with its large thermal conductivity and high melting point is well suited for surviving the thermal effects of beam exposure with this power density. We are exploring the CVD properties and how it can be used as a robust beam position monitor. Results of some beam tests with 0.5MW beams will be presented.

  8. Collins and Sivers Transverse Spin Asymmetries for Pions and Kaons on Deuterons

    CERN Document Server

    Aleeksev, M; Alexandrov, Yu; Alexeev, G D; Amoroso, A; Arbuzov, A; Badelek, B; Balestra, F; Ball, J; Barth, J; Baum, G; Bedfer, Y; Bernet, C; Bertini, R; Bettinelli, M; Birsa, R; Bisplinghoff, J; Bordalo, P; Bradamante, Franco; Bravar, A; Bressan, A; Brona, G; Burtin, E; Bussa, M P; Chapiro, A; Chiosso, M; Cicuttin, A; Colantoni, M; Costa, S; Crespo, M L; Dalla Torre, S; Dafni, T; Das, S; Das-Gupta, S S; De Masi, R; Dedek, N; Denisov, O Yu; Dhara, L; Díaz, V; Dinkelbach, A M; Donskov, S V; Dorofeev, V A; Doshita, N; Duic, V; Dünnweber, W; Eversheim, P D; Eyrich, W; Faessler, M; Falaleev, V; Ferrero, A; Ferrero, L; Finger, M; Finger, M Jr; Fischer, H; Franco, C; Franz, J; Friedrich, J M; Frolov, V; Garfagnini, R; Gautheron, F; Gavrichtchouk, O P; Gazda, R; Gerassimov, S; Geyer, R; Giorgi, M; Gobbo, B; Görtz, S; Gorin, A M; Grabmuller, S; Grajek, O A; Grasso, A; Grube, B; Gushterski, R; Guskov, A; Haas, F; Hannappel, J; von, D; Harrach; Hasegawa, T; Heckmann, J; Hedicke, S; Heinsius, F H; Hermann, R; Hess, C; Hinterberger, F; Von Hodenberg, M; Horikawa, N; Horikawa, S; D'Hose, N; Ilgner, C; Ioukaev, A I; Ishimoto, S; Ivanov, O; Ivanshin, Yu; Iwata, T; Jahn, R; Janata, A; Jasinski, P; Joosten, R; Jouravlev, N I; Kabuss, E; Kang, D; Ketzer, B; Khaustov, G V; Khokhlov, Yu A; Kisselev, Yu; Klein, F; Klimaszewski, K; Koblitz, S; Koivuniemi, J H; Kolosov, V N; Komissarov, E V; Kondo, K; Königsmann, K C; Konorov, I; Konstantinov, V F; Korentchenko, A S; Korzenev, A; Kotzinian, A M; Koutchinski, N A; Kuznetsov, O; Kral, A; Kravchuk, N P; Kroumchtein, Z V; Kühn, R; Kunne, Fabienne; Kurek, K; Ladygin, M E; Lamanna, M; Le Goff, J M; Lednev, A A; Lehmann, A; Levorato, S; Lichtenstadt, J; Liska, T; Ludwig, I; Maggiora, A; Maggiora, M; Magnon, A; Mallot, G K; Mann, A; Marchand, C; Marroncle, J; Martin, A; Marzec, J; Massmann, F; Matsuda, T; Maksimov, A N; Meyer, W; Mielech, A; Mikhailov, Yu V; Moinester, M A; Mutter, A; Nagaytsev, A; Nagel, T; Nahle, O; Nassalski, J; Neliba, S; Nerling, F; Neubert, S; Neyret, D P; Nikolaenko, V I; Nikolaev, K; Olshevskii, A G; Ostrick, M; Padee, A; Pagano, P; Panebianco, S; Panknin, R; Panzieri, D; Paul, S; Pawlukiewicz-Kaminska, B; Peshekhonov, D V; Peshekhonov, V D; Piragino, G; Platchkov, S; Pochodzalla, J; Polak, J; Polyakov, V A; Pretz, J; Procureur, S; Quintans, C; Rajotte, J F; Ramos, S; Rapatsky, V; Reicherz, G; Reggiani, D; Richter, A; Robinet, F; Rocco, E; Rondio, E; Rozhdestvensky, A M; Ryabchikov, D I; Samoylenko, V D; Sandacz, A; Santos, H; Sapozhnikov, M G; Sarkar, S; Savin, I A; Schiavon, Paolo; Schill, C; Schmitt, L; Schonmeier, P; Schroder, W; Shevchenko, O Yu; Siebert, H W; Silva, L; Sinha, L; Sissakian, A N; Slunecka, M; Smirnov, G I; Sosio, S; Sozzi, F; Srnka, A; Stinzing, F; Stolarski, M; Sugonyaev, V P; Sulc, M; Sulej, R; Tchalishev, V V; Tessaro, S; Tessarotto, F; Teufel, A; Tkatchev, L G; Venugopal, G; Virius, M; Vlassov, N V; Vossen, A; Webb, R; Weise, E; Weitzel, Q; Windmolders, R; Wirth, S; Wislicki, W; Wollny, H; Zaremba, K; Zavertyaev, M; Zemlyanichkina, E; Zhao, J; Ziegler, R; Zvyagin, A

    2009-01-01

    The measurements of the Collins and Sivers asymmetries of identified hadrons produced in deep-inelastic scattering of 160 GeV/c muons on a transversely polarised 6LiD target at COMPASS are presented. The results for charged pions and charged and neutral kaons correspond to all data available, which were collected from 2002 to 2004. For all final state particles both the Collins and Sivers asymmetries turn out to be small, compatible with zero within the statistical errors, in line with the previously published results for not identified charged hadrons, and with the expected cancellation between the u- and d-quark contributions.

  9. Space Charge Compensation in the Linac4 Low Energy Beam Transport Line with Negative Hydrogen Ions

    CERN Document Server

    Valerio-Lizarraga, C; Leon-Monzon, I; Lettry, J; Midttun, O; Scrivens, R

    2014-01-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Tranport (LEBT) using the package IBSimu1, which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H- beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  10. Direct measurements of Ab and Ac using vertex and kaon charge tags at the SLAC detector.

    Science.gov (United States)

    Abe, Koya; Abe, Kenji; Abe, T; Adam, I; Akimoto, H; Aston, D; Baird, K G; Baltay, C; Band, H R; Barklow, T L; Bauer, J M; Bellodi, G; Berger, R; Blaylock, G; Bogart, J R; Bower, G R; Brau, J E; Breidenbach, M; Bugg, W M; Burke, D; Burnett, T H; Burrows, P N; Calcaterra, A; Cassell, R; Chou, A; Cohn, H O; Coller, J A; Convery, M R; Cook, V; Cowan, R F; Crawford, G; Damerell, C J S; Daoudi, M; Dasu, S; de Groot, N; de Sangro, R; Dong, D N; Doser, M; Dubois, R; Erofeeva, I; Eschenburg, V; Etzion, E; Fahey, S; Falciai, D; Fernandez, J P; Flood, K; Frey, R; Hart, E L; Hasuko, K; Hertzbach, S S; Huffer, M E; Huynh, X; Iwasaki, M; Jackson, D J; Jacques, P; Jaros, J A; Jiang, Z Y; Johnson, A S; Johnson, J R; Kajikawa, R; Kalelkar, M; Kang, H J; Kofler, R R; Kroeger, R S; Langston, M; Leith, D W G; Lia, V; Lin, C; Mancinelli, G; Manly, S; Mantovani, G; Markiewicz, T W; Maruyama, T; McKemey, A K; Messner, R; Moffeit, K C; Moore, T B; Morii, M; Muller, D; Murzin, V; Narita, S; Nauenberg, U; Neal, H; Nesom, G; Oishi, N; Onoprienko, D; Osborne, L S; Panvini, R S; Park, C H; Peruzzi, I; Piccolo, M; Piemontese, L; Plano, R J; Prepost, R; Prescott, C Y; Ratcliff, B N; Reidy, J; Reinertsen, P L; Rochester, L S; Rowson, P C; Russell, J J; Saxton, O H; Schalk, T; Schumm, B A; Schwiening, J; Serbo, V V; Shapiro, G; Sinev, N B; Snyder, J A; Staengle, H; Stahl, A; Stamer, P; Steiner, H; Su, D; Suekane, F; Sugiyama, A; Suzuki, A; Swartz, M; Taylor, F E; Thom, J; Torrence, E; Usher, T; Va'vra, J; Verdier, R; Wagner, D L; Waite, A P; Walston, S; Weidemann, A W; Weiss, E R; Whitaker, J S; Williams, S H; Willocq, S; Wilson, R J; Wisniewski, W J; Wittlin, J L; Woods, M; Wright, T R; Yamamoto, R K; Yashima, J; Yellin, S J; Young, C C; Yuta, H

    2005-03-11

    Exploiting the manipulation of the SLAC Linear Collider electron-beam polarization, we present precise direct measurements of the parity-violation parameters A(c) and A(b) in the Z-boson-c-quark and Z-boson-b-quark coupling. Quark-antiquark discrimination is accomplished via a unique algorithm that takes advantage of the precise SLAC Large Detector charge coupled device vertex detector, employing the net charge of displaced vertices as well as the charge of kaons that emanate from those vertices. From the 1996-1998 sample of 400 000 Z decays, produced with an average beam polarization of 73.4%, we find A(c)=0.673+/-0.029(stat)+/-0.023(syst) and A(b)=0.919+/-0.018(stat)+/-0.017(syst).

  11. Transverse target single-spin asymmetry in inclusive electroproduction of charged pions and kaons

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). 2. Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Laboratory of Physics; Akopov, N. [Yerevan Physics Institute (Argentina); Akopov, Z. [DESY Hamburg (Germany)] [and others; Collaboration: HERMES Collaboration

    2013-10-15

    Single-spin asymmetries were investigated in inclusive electroproduction of charged pions and kaons from transversely polarized protons at the HERMES experiment. The asymmetries were studied as a function of the azimuthal angle {psi} about the beam direction between the target-spin direction and the hadron production plane, the transverse hadron momentum P{sub T} relative to the direction of the incident beam, and the Feynman variable x{sub F}. The sin {psi} amplitudes are positive for {pi}{sup +} and K{sup +}, slightly negative for {pi}{sup -} consistent with zero for K{sup -}, with particular P{sub T} but weak x{sub F} dependences. Especially large asymmetries are observed for two small subsamples of events, where also the scattered electron was recorded by the spectrometer.

  12. Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers

    CERN Document Server

    Achenbach, P; Bernauer, J C; Böhm, R; Bosnar, D; Bösz, M; Debenjak, L; Distler, M O; Esser, A; Friščić, I; de la Paz, M Gómez Rodríguez; Makek, M; Merkel, H; Müller, U; Nungesser, L; Pochodzalla, J; Potokar, M; Majos, S Sánchez; Schlimme, B S; Širca, S; Weinriefer, M; 10.1016/j.nima.2011.03.039

    2011-01-01

    Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An algorithm was developed for operating two large-sized MWPCs in a strong background environment with multiple-particle tracks. Resulting efficiencies were determined as a function of the electron beam current and on the signal amplitudes. Because of the different energy-losses of pions, kaons, and protons in the momentum range of the s...

  13. Multi-K¯ nuclei and kaon condensation

    Science.gov (United States)

    Gazda, D.; Friedman, E.; Gal, A.; Mareš, J.

    2008-04-01

    We extend previous relativistic mean-field (RMF) calculations of multi-K¯ nuclei, using vector boson fields with SU(3) PPV coupling constants and scalar boson fields constrained phenomenologically. For a given core nucleus, the resulting K¯ separation energy BK¯, as well as the associated nuclear and K¯-meson densities, saturate with the number κ of K¯ mesons for κ>κsat~10. Saturation appears robust against a wide range of variations, including the RMF nuclear model used and the type of boson fields mediating the strong interactions. Because BK¯ generally does not exceed 200 MeV, it is argued that multi-K¯ nuclei do not compete with multihyperonic nuclei in providing the ground state of strange hadronic configurations and that kaon condensation is unlikely to occur in strong-interaction self-bound strange hadronic matter. Last, we explore possibly self-bound strange systems made of neutrons and K¯0 mesons, or protons and K- mesons, and study their properties.

  14. GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

    CERN Multimedia

    2004-01-01

    GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

  15. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10Â MeV

    Science.gov (United States)

    Busold, S.; Schumacher, D.; Deppert, O.; Brabetz, C.; Kroll, F.; Blažević, A.; Bagnoud, V.; Roth, M.

    2014-03-01

    We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 109 particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E0 at FWHM). A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf) field is applied via a rf cavity for energy compression at a synchronous phase of -90 deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  16. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10 MeV

    Directory of Open Access Journals (Sweden)

    S. Busold

    2014-03-01

    Full Text Available We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 10^{9} particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E_{0} at FWHM. A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf field is applied via a rf cavity for energy compression at a synchronous phase of -90  deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  17. Tertiary particle production and target optimization of the H2 beam line in the SPS North Area

    CERN Document Server

    Tellander, Felix

    2016-01-01

    H2 beam line of SPS North Area is a high energy, high resolution and multipurpose particle beam line. It is able to transport secondary hadron and pure electron beams with momenta between 10 and 400 GeV/c to be exploited by several different experiments. In this work, tertiary particle production from a secondary target placed in the line is studied. The introduction of this “filter” target enhances the middle to low momentum hadron (20 - 60 GeV/c) and electron production. In this work, a systematic Monte Carlo simulation study using a GEANT 4 based package, G4beamline, has been performed in order to investigate the tertiary particle production from several different targets. More specifically, Cu, W and polyethylene targets with different thicknesses have been studied. The proton over pi+ ratio is of particular interest, as well as the optimal electron production for several momenta. The present work will act as a reference to be used by the future test-beam users of the line as an indication of the expe...

  18. A new concept for the control of a slow-extracted beam in a line with rotational optics, 2

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    For pt.I see ibid., vol.430, p.512-22, 1999. The current trend in hadron therapy is towards high-precision, conformal scanning of tumours with a `pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow- extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer- pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from `hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined p...

  19. A new concept for the control of a slow-extracted beam in a line with rotational optics: Part II

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    The current trend in hadrontherapy is towards high-precision, conformal scanning of tumours with a 'pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow-extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer-pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from 'hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined phase shifter and 'stepper', at a point close to ...

  20. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Science.gov (United States)

    Viezzer, E.; Dux, R.; Dunne, M. G.

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  1. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade.

    Science.gov (United States)

    Viezzer, E; Dux, R; Dunne, M G

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  2. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Viezzer, E., E-mail: eleonora.viezzer@ipp.mpg.de, E-mail: eviezzer@us.es [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Department of Atomic, Molecular, and Nuclear Physics, University of Seville, Avda. Reina Mercedes, 41012 Seville (Spain); Dux, R.; Dunne, M. G. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-11-15

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D{sub α}. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  3. A transverse emittance and acceptance measurement system in a low-energy beam transport line

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, H., E-mail: kashiwagi.hirotsugu@jaea.go.jp; Miyawaki, N.; Kurashima, S.; Okumura, S. [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of {sup 16}O{sup 6+} from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.

  4. Fast characterization of line-end shortening and application of novel correction algorithms in e-beam direct write

    Science.gov (United States)

    Freitag, Martin; Choi, Kang-Hoon; Gutsch, Manuela; Hohle, Christoph; Galler, Reinhard; Krüger, Michael; Weidenmueller, Ulf

    2011-04-01

    For the manufacturing of semiconductor technologies following the ITRS roadmap, we will face the nodes well below 32nm half pitch in the next 2~3 years. Despite being able to achieve the required resolution, which is now possible with electron beam direct write variable shaped beam (EBDW VSB) equipment and resists, it becomes critical to precisely reproduce dense line space patterns onto a wafer. This exposed pattern must meet the targets from the layout in both dimensions (horizontally and vertically). For instance, the end of a line must be printed in its entire length to allow a later placed contact to be able to land on it. Up to now, the control of printed patterns such as line ends is achieved by a proximity effect correction (PEC) which is mostly based on a dose modulation. This investigation of the line end shortening (LES) includes multiple novel approaches, also containing an additional geometrical correction, to push the limits of the available data preparation algorithms and the measurement. The designed LES test patterns, which aim to characterize the status of LES in a quick and easy way, were exposed and measured at Fraunhofer Center Nanoelectronic Technologies (CNT) using its state of the art electron beam direct writer and CD-SEM. Simulation and exposure results with the novel LES correction algorithms applied to the test pattern and a large production like pattern in the range of our target CDs in dense line space features smaller than 40nm will be shown.

  5. Measurement of Production Properties of Positively Charged Kaons in Proton-Carbon Interactions at 31 GeV/c

    CERN Document Server

    Abgrall, N; Anticic, T; Antoniou, N; Argyriades, J; Baatar, B; Blondel, A; Blumer, J; Bogusz, M; Boldizsar, L; Bravar, A; Brooks, W; Brzychczyk, J; Bubak, A; Bunyatov, S A; Busygina, O; Cetner, T; Choi, K U; Christakoglou, P; Czopowicz, T; Davis, N; Diakonos, F; Di Luise, S; Dominik, W; Dumarchez, J; Engel, R; Ereditato, A; Esposito, L S; Feofilov, G A; Fodor, Z; Ferrero, A; Fulop, A; Garrido, X; Gazdzicki, M; Golubeva, M; Grebieszkow, K; Grzeszczuk, A; Guber, F; Haesler, A; Hakobyan, H; Hasegawa, T; Idczak, R; Ivanov, Y; Ivashkin, A; Kadija, K; Kapoyannis, A; Katrynska, N; Kielczewska, D; Kikola, D; Kim, J H; Kirejczyk, M; Kisiel, J; Kobayashi, T; Kochebina, O; Kolesnikov, V I; Kolev, D; Kondratiev, V P; Korzenev, A; Kowalski, S; Krasnoperov, A; Kuleshov, S; Kurepin, A; Lacey, R; Lagoda, J; Laszlo, A; Lyubushkin, V V; Mackowiak-Pawlowska, M; Majka, Z; Malakhov, A I; Marchionni, A; Marcinek, A; Maris, I; Marin, V; Matulewicz, T; Matveev, V; Melkumov, G L; Meregaglia, A; Messina, M; Mrowczynski, St; Murphy, S; Nakadaira, T; Nishikawa, K; Palczewski, T; Palla, G; Panagiotou, A D; Paul, T; Peryt, W; Petukhov, O; Planeta, R; Pluta, J; Popov, B A; Posiadala, M; Pulawski, S; Rauch, W; Ravonel, M; Renfordt, R; Robert, A; Rohrich, D; Rondio, E; Rossi, B; Roth, M; Rubbia, A; Rybczynski, M; Sadovsky, A; Sakashita, K; Sekiguchi, T; Seyboth, P; Shibata, M; Skrzypczak, E; Slodkowski, M; Staszel, P; Stefanek, G; Stepaniak, J; Strabel, C; Strobele, H; Susa, T; Szaflik, P; Szuba, M; Tada, M; Taranenko, A; Tereshchenko, V; Tsenov, R; Turko, L; Ulrich, R; Unger, M; Vassiliou, M; Veberic, D; Vechernin, V V; Vesztergombi, G; Wilczek, A; Wlodarczyk, Z; Wojtaszek-Szwarc, A; Yi, J G; Yoo, I K; Zambelli, L; Zipper, W

    2012-01-01

    Spectra of positively charged kaons in p+C interactions at 31 GeV/c were measured with the NA61/SHINE spectrometer at the CERN SPS. The analysis is based on the full set of data collected in 2007 with a graphite target with a thickness of 4% of a nuclear interaction length. Interaction cross sections and charged pion spectra were already measured using the same set of data. These new measurements in combination with the published ones are required to improve predictions of the neutrino flux for the T2K long baseline neutrino oscillation experiment in Japan. In particular, the knowledge of kaon production is crucial for precisely predicting the intrinsic electron neutrino component and the high energy tail of the T2K beam. The results are presented as a function of laboratory momentum in 2 intervals of the laboratory polar angle covering the range from 20 up to 240 mrad. The kaon spectra are compared with predictions of several hadron production models. Using the published...

  6. Measurement of the Induced Polarization of Lambda (1116) in Kaon Electroproduction with CLAS

    Energy Technology Data Exchange (ETDEWEB)

    Marianna Gabrielyan, Brian Raue, Seema Dhamija, Daniel S. Carman

    2010-08-01

    The CLAS Collaboration is using the p(e,e[prime]K+p)pi- reaction to measure the induced polarization of the electroproduced Lambda(1116). In this experiment a 5.499-GeV electron beam was incident upon an unpolarized liquid-hydrogen target. The CEBAF Large Acceptance Spectrometer (CLAS) was used to detect the scattered electron, the kaon, and the decay proton from the Lambda hyperon. CLAS allowed for a large kinematic acceptance in Q2(0.75<=Q2<=3.5 GeV2) and W(1.6<=W<=3.0 GeV), as well as the kaon center-of-mass scattering angle. The goal is to map out the kinematic dependencies for the induced polarization in order to provide new constraints on models of K-hyperon production. Along with previously published photo- and electroproduction cross sections and polarization observables from CLAS, LEPS, SAPHIR, and GRAAL, these new induced polarization data are needed in coupled-channel analyses to search for previously unobserved s-channel resonances. Preliminary polarization results are presented.

  7. Kaon electroproduction at large four-momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Pete Markowitz

    2003-06-16

    Exclusive H(e,e'K)Y data were taken in January, March and April of 2001 at the Jefferson Lab Hall A. The electrons and kaons were detected in coincidence in the hall's two High Resolution Spectrometers (HRS). The kaon arm of the pair had been specifically outfitted with two aerogel Cerenkov threshold detectors, designed to separately provide pion and proton particle identification thus allowing kaon identification. Preliminary data show the cross section's dependence on the invariant mass, W, along with results of systematic studies. Ultimately the data will be used to perform a Rosenbluth Separation as well, separating the longitudinal from the transverse response functions.

  8. Exposing strangeness: Projections for kaon electromagnetic form factors

    Science.gov (United States)

    Gao, Fei; Chang, Lei; Liu, Yu-Xin; Roberts, Craig D.; Tandy, Peter C.

    2017-08-01

    A continuum approach to the kaon and pion bound-state problems is used to reveal their electromagnetic structure. For both systems, when used with parton distribution amplitudes appropriate to the scale of the experiment, Standard Model hard-scattering formulas are accurate to within 25% at momentum transfers Q2≈8 GeV2. There are measurable differences between the distribution of strange and normal matter within the kaons, e.g. the ratio of their separate contributions reaches a peak value of 1.5 at Q2≈6 GeV2. Its subsequent Q2 evolution is accurately described by the hard scattering formulas. Projections for the ratio of kaon and pion form factors at timelike momenta beyond the resonance region are also presented. These results and projections should prove useful in planning next-generation experiments.

  9. Baryon masses at nonzero isospin/kaon density

    CERN Document Server

    Detmold, William

    2013-01-01

    We present a lattice QCD calculation of the ground-state energy shifts of various baryons in a medium of pions or kaons at a single value of the quark mass corresponding to a pion mass of m_\\pi~390 MeV and a kaon mass of m_K~540 MeV, and in a spatial volume V (4fm)^3. All systems are created using a canonical formalism in which quark propagators are contracted into correlation functions of fixed isospin/kaon density. We study four different systems, \\Sigma^+(\\pi^+)^n, \\Xi^0(\\pi^+)^n, p(K^+)^n, and n(K^+)^n, for up to n=11 mesons. From the ground-state energy shifts we extract two- and three-body scattering parameters, as well as linear combinations of low-energy constants appearing in tree-level chiral perturbation theory.

  10. Discrimination of charged particles in a neutral beam line by using a solid scintillation detector

    Science.gov (United States)

    Woo, Jong-Kwan; Ko, Jewou; Liu, Dong

    2017-01-01

    In the past several decades, many studies have been conducted to search for non-baryonic dark matter, such as weakly interactive massive particles (WIMPs). In the search for WIMPs, charged particles incident on the detector are background particles because WIMPs are neutral. Charged particles originate from various sources, such as cosmic rays and laboratory materials surrounding the main detector. Therefore, a veto that discriminates charged particles can improve the particle-detection efficiency of the entire experiment for detecting WIMPs. Here, we investigate in the thickness range of 1 mm to 5 mm, the optimal thickness of a polystyrene scintillator as a chargedparticle veto detector. We found that 3-mm-thick polystyrene provides the best performance to veto charged particles and the charged-particle background in the search for the WIMP signal. Furthermore, we fabricated 3-mm-thick and 5-mm-thick polystyrene charged particle veto detectors that will be used in an underground laboratory in the search for WIMP dark matter. After exposing those detectors are the actual beam line, we compared the rate of charged particles measured using those detectors and the rate simulated through a Monte Carlo simulation.

  11. Valence-quark distribution functions in the kaon and pion

    Science.gov (United States)

    Chen, Chen; Chang, Lei; Roberts, Craig D.; Wan, Shaolong; Zong, Hong-Shi

    2016-04-01

    We describe expressions for pion and kaon dressed-quark distribution functions that incorporate contributions from gluons which bind quarks into these mesons and hence overcome a flaw of the commonly used handbag approximation. The distributions therewith obtained are purely valence in character, ensuring that dressed quarks carry all the meson's momentum at a characteristic hadronic scale and vanish as (1 -x )2 when Bjorken-x →1 . Comparing such distributions within the pion and kaon, it is apparent that the size of S U (3 ) -flavor symmetry breaking in meson parton distribution functions is modulated by the flavor dependence of dynamical chiral symmetry breaking. Corrections to these leading-order formulas may be divided into two classes, responsible for shifting dressed-quark momentum into glue and sea quarks. Working with available empirical information, we build an algebraic framework that is capable of expressing the principal impact of both classes of corrections. This enables a realistic comparison with experiment which allows us to identify and highlight basic features of measurable pion and kaon valence-quark distributions. We find that whereas roughly two thirds of the pion's light-front momentum is carried by valence dressed quarks at a characteristic hadronic scale; this fraction rises to 95% in the kaon; evolving distributions with these features to a scale typical of available Drell-Yan data produces a kaon-to-pion ratio of u -quark distributions that is in agreement with the single existing data set, and predicts a u -quark distribution within the pion that agrees with a modern reappraisal of π N Drell-Yan data. Precise new data are essential in order to validate this reappraisal and because a single modest-quality measurement of the kaon-to-pion ratio cannot be considered definitive.

  12. Valence-quark distribution functions in the kaon and pion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chen; Chang, Lei; Roberts, Craig D.; Wan, Shaolong; Zong, Hong-Shi

    2016-04-18

    We describe expressions for pion and kaon dressed-quark distribution functions that incorporate contributions from gluons which bind quarks into these mesons and hence overcome a flaw of the commonly used handbag approximation. The distributions therewith obtained are purely valence in character, ensuring that dressed quarks carry all the meson’s momentum at a characteristic hadronic scale and vanish as ( 1 - x ) 2 when Bjorken- x → 1 . Comparing such distributions within the pion and kaon, it is apparent that the size of S U ( 3 ) -flavor symmetry breaking in meson parton distribution functions is modulated by the flavor dependence of dynamical chiral symmetry breaking. Corrections to these leading-order formulas may be divided into two classes, responsible for shifting dressed-quark momentum into glue and sea quarks. Working with available empirical information, we build an algebraic framework that is capable of expressing the principal impact of both classes of corrections. This enables a realistic comparison with experiment which allows us to identify and highlight basic features of measurable pion and kaon valence-quark distributions. We find that whereas roughly two thirds of the pion’s light-front momentum is carried by valence dressed quarks at a characteristic hadronic scale; this fraction rises to 95% in the kaon; evolving distributions with these features to a scale typical of available Drell-Yan data produces a kaon-to-pion ratio of u -quark distributions that is in agreement with the single existing data set, and predicts a u -quark distribution within the pion that agrees with a modern reappraisal of π N Drell-Yan data. Precise new data are essential in order to validate this reappraisal and because a single modest-quality measurement of the kaon-to-pion ratio cannot be considered definitive.

  13. Optics Measurements and Matching of TT2-TT10 Line for Injection of the LHC Beam in the SPS

    CERN Document Server

    Benedetto, E; Guerrero, A; Jacquet, D

    2008-01-01

    A well matched injection in the SPS is very important for preserving the emittance of the LHC beam. The paper presents the algorithms used for the analysis and the results of the optics measurements done in the transfer line TT2-TT10 and in the SPS. The dispersion is computed by varying the beam momentum and recording the offsets at the BPMs, while the Twiss parameters and emittance measurements in TT2-TT10 are performed with beam profile monitors equipped with OTR screens. These results are completed by those obtained with a matching monitor installed in the SPS as a prototype for the LHC. This device makes use of an OTR screen and a fast acquisition system, to get the turn by turn beam profiles right at injection in the ring, from which the beam mismatch is computed and compared with the results obtained in the line. Finally, on the basis of such measurements, a betatron and dispersion matching of TT2-TT10 for injection in the SPS has been performed and successfully put in operation.

  14. A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Bing, E-mail: tangb364@126.com; Ma, Ruigang; Huang, Qinghua; Chen, Lihua; Ma, Yingjun; Cui, Baoqun; Jiang, Weisheng

    2013-12-15

    Highlights: • The modular design makes the maintenance of target station easily. • The diagnosis for low intensity beam is solved. • A positive surface ion source has been developed. -- Abstract: A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility (BRISOL) has been built in China Institute of Atomic Energy (CIAE). The test-bench consists of target station, charge exchange cell, mass separator, quadrupole, hexapole, multipole and beam diagnostic system. It is nearly the same configuration as the first stage of BRISOL and all these components will be used on the BRISOL. A series of experiments have been carried out on this test-bench, and the primary results showed that all the components worked well. A Li{sup +} beam has been generated from the positive surface-ionization source and its emittance and the transmission of the beam line have been measured. The design, construction and experimental results of this test-bench have been presented.

  15. Design of Main Control Console Software in EAST Neutral Beam Injector's Control System for the First Beam Line

    Science.gov (United States)

    Wu, De-Yun; Hu, Chun-Dong; Sheng, Peng; Zhao, Yuan-Zhe; Zhang, Xiao-Dan; Cui, Qing-Long

    2013-10-01

    Neutral beam injector is one of the main plasma heating and plasma current driving methods for experimental advanced superconducting tokomaks (EAST). In order to realize visual operation of EAST neutral beam injector's control system (NBICS), main control console (MCC) is developed to work as the human-machine interface between the NBICS and physical operator. It can meet the requirements of visual control of NBICS by providing a user graphic interface. With the specific algorithms, the setup of power supply sequence is relatively independent and simple. Displaying the real-time feedback of the subsystems provides a reference for operators to monitor the status of the system. The MCC software runs on a Windows system and uses C++ language code while using client/server (C/S) mode, multithreading and cyclic redundancy check technology. The experimental results have proved that MCC provides a stability and reliability operation of NBICS and works as an effective man-machine interface at the same time.

  16. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Valerio-Lizarraga, Cristhian A., E-mail: cristhian.alfonso.valerio.lizarraga@cern.ch [CERN, Geneva (Switzerland); Departamento de Investigación en Física, Universidad de Sonora, Hermosillo (Mexico); Lallement, Jean-Baptiste; Lettry, Jacques; Scrivens, Richard [CERN, Geneva (Switzerland); Leon-Monzon, Ildefonso [Facultad de Ciencias Fisico-Matematicas, Universidad Autónoma de Sinaloa, Culiacan (Mexico); Midttun, Øystein [CERN, Geneva (Switzerland); University of Oslo, Oslo (Norway)

    2014-02-15

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H{sup −} beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  17. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions.

    Science.gov (United States)

    Valerio-Lizarraga, Cristhian A; Lallement, Jean-Baptiste; Leon-Monzon, Ildefonso; Lettry, Jacques; Midttun, Øystein; Scrivens, Richard

    2014-02-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H(-) beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  18. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Science.gov (United States)

    Valerio-Lizarraga, Cristhian A.; Lallement, Jean-Baptiste; Leon-Monzon, Ildefonso; Lettry, Jacques; Midttun, Øystein; Scrivens, Richard

    2014-02-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H- beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  19. Kaon Eletromagnetic Form Factor in the Light-Front Formalism

    CERN Document Server

    Pereira, F P; Frederico, T; Tomio, L; Pereira, Fabiano P.; Tomio, Lauro

    2005-01-01

    Numerical calculations are performed and compared to the experimental data for the electromagnetic form factor of the kaon, which is extracted from both components of the electromagnetic current, $J^{+}$ and $J^{-}$, with a pseudo-scalar coupling of the quarks to the kaon. In the case of $J^{+}$ there is no pair term contribution in the Drell-Yan frame ($q^{+}=0$). However, for $J^{-}$, the pair term contribution is different from zero and necessary in order to preserve the rotational symmetry of the current. The free parameters are the quark masses and the regulator mass.

  20. Status of the SPES-charge breeder (SPES-CB) and its beam line at INFN-LNL

    Energy Technology Data Exchange (ETDEWEB)

    Galatá, Àlessio; Comunian, M. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Bellan, L. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Dipartimento di Fisica e Astronomia, Universitá degli Studi di Padova e Sezione INFN, Padova (Padova) (Italy); Maggiore, M.; Patti, G.; Roncolato, C.; Bisoffi, G. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Russo, A.D.; Calabretta, L. [INFN-Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Angot, J.; Lamy, T. [LPSC – Université Grenoble Alpes – CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex (France)

    2016-06-01

    The Selective Production of Exotic Species (SPES) facility is under construction at INFN-LNL: aim of this project is the production, ionization and post-acceleration of radioactive ions to perform forefront research in nuclear physics. Radioactive species will be produced by fissions induced by a proton beam impinging on an UC{sub x} target: the proton beam will be delivered by a room temperature cyclotron (built by the Best Company) with a maximum energy of 40 MeV and 0.25 mA of maximum current. The radioactive species produced in the Target-Ion-Source system, extracted as a 1+ beam, cooled in a RFQ-cooler and purified from the isobars contaminants through a High Resolution Mass Spectrometer (HRMS). In order to allow post acceleration with the superconducting linac ALPI at INFN-LNL (up to 10 MeV/A for A/q = 7), an ECR-based charge breeding technique (ECR-CB) was chosen: in particular the SPES-CB was developed by the LPSC Grenoble on the basis of the Phoenix booster. The SPES-CB will be equipped with a complete test bench, totally integrated with the SPES beam line: in particular, in order to avoid beam contaminations induced by the impurities present inside the SPES-CB, and to have high transmission for a beam of very low intensity, special attention was paid not only to the transport efficiency but also to the resolution of the spectrometer downstream the charge breeder, with the design of a Medium Resolution Mass Spectrometer (MRMS). In the following paper the technical aspects connected with SPES-CB, its beam line and the transport of highly charged radioactive ions will be described.

  1. Status of the SPES-charge breeder (SPES-CB) and its beam line at INFN-LNL

    Science.gov (United States)

    Galatá, Àlessio; Comunian, M.; Bellan, L.; Maggiore, M.; Patti, G.; Roncolato, C.; Bisoffi, G.; Russo, A. D.; Calabretta, L.; Angot, J.; Lamy, T.

    2016-06-01

    The Selective Production of Exotic Species (SPES) facility is under construction at INFN-LNL: aim of this project is the production, ionization and post-acceleration of radioactive ions to perform forefront research in nuclear physics. Radioactive species will be produced by fissions induced by a proton beam impinging on an UCx target: the proton beam will be delivered by a room temperature cyclotron (built by the Best Company) with a maximum energy of 40 MeV and 0.25 mA of maximum current. The radioactive species produced in the Target-Ion-Source system, extracted as a 1+ beam, cooled in a RFQ-cooler and purified from the isobars contaminants through a High Resolution Mass Spectrometer (HRMS). In order to allow post acceleration with the superconducting linac ALPI at INFN-LNL (up to 10 MeV/A for A/q = 7), an ECR-based charge breeding technique (ECR-CB) was chosen: in particular the SPES-CB was developed by the LPSC Grenoble on the basis of the Phoenix booster. The SPES-CB will be equipped with a complete test bench, totally integrated with the SPES beam line: in particular, in order to avoid beam contaminations induced by the impurities present inside the SPES-CB, and to have high transmission for a beam of very low intensity, special attention was paid not only to the transport efficiency but also to the resolution of the spectrometer downstream the charge breeder, with the design of a Medium Resolution Mass Spectrometer (MRMS). In the following paper the technical aspects connected with SPES-CB, its beam line and the transport of highly charged radioactive ions will be described.

  2. Protocol of image guided off-line using cone beam CT megavoltage; Protocolo de imagen guiada off-line mediante Cone Beam CT de megavoltaje

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Ruiz-Zorrilla, J.; Fernandez Leton, J. P.; Perez Moreno, J. M.; Zucca Aparicio, D.; Minambres Moro, A.

    2013-07-01

    The goal of image guided protocols offline is to reduce systematic errors in positioning of the patient in the treatment unit, being more important than the random errors, since the systematic have one contribution in the margin of the CTV to the PTV. This paper proposes a protocol for image guided offline with the different actions to take with their threshold values evaluated previously by anatomic location in a sample of 474 patients and 4821Cone beam Megavoltaje CT (CBCT). (Author)

  3. Commissioning of the Beam Interlock System for the TT40 and TT41 Transfer Lines of the SPS

    CERN Document Server

    Wenninger, J; Kain, V; CERN. Geneva. AB Department

    2007-01-01

    The extraction area of LSS4 in the SPS and the TT40 and TT41 transfer lines have been equipped with a new interlock system to protect the machine elements against beam induced failure during operation with the high intensity CNGS beams. The system commissioning that was performed during the 2006 SPS run followed pre-defined commissioning procedures. An extensive WEB based documentation of the tests has been established to track the state of the interlock system, in particular of interlock references. This document presents a short summary of the commissioning as well as the complete documentation of the interlock tests.

  4. Kaon condensation in neutron stars and high density behaviour of nuclear symmetry energy

    CERN Document Server

    Kubis, S

    1999-01-01

    We study the influence of a high density behaviour of the nuclear symmetry energy on a kaon condensation in neutron stars. We find that the symmetry energy typical for several realistic nuclear potentials, which decreases at high densities, inhibits kaon condensation for weaker kaon-nucleon couplings. There exists a threshold coupling above which the kaon condensate forms at densities exceeding some critical value. This is in contrast to the case of rising symmetry energy, as e.g. for relativistic mean field models, when the kaon condensate can form for any coupling at a sufficiently high density. Properties of the condensate are also different in both cases.

  5. Kaon photoproduction from the deuteron in a Regge-plus-resonance approach

    CERN Document Server

    Vancraeyveld, Pieter; Ryckebusch, Jan; Vrancx, Tom

    2012-01-01

    We present a Regge-inspired effective-Lagrangian framework for kaon photoproduction from the deuteron. Quasi-free kaon production is investigated using the Regge-plus-resonance (RPR) elementary operator within the relativistic plane-wave impulse approximation. The RPR model was developed to describe photoinduced and electroinduced charged-kaon production off protons. We show how this elementary operator can be transformed in order to account for the production of neutral kaons from both protons and neutrons. The model results for kaon photoproduction from the deuteron compare favourably to the 2H(g,K)YN data published to date.

  6. Kaon photoproduction from the deuteron in a Regge-plus-resonance approach

    Energy Technology Data Exchange (ETDEWEB)

    Vancraeyveld, P., E-mail: pieter.vancraeyveld@ugent.be [Department of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium); De Cruz, L. [Department of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium); Ryckebusch, J., E-mail: jan.ryckebusch@ugent.be [Department of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium); Vrancx, T. [Department of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium)

    2013-01-02

    We present a Regge-inspired effective-Lagrangian framework for kaon photoproduction from the deuteron. Quasi-free kaon production is investigated using the Regge-plus-resonance (RPR) elementary operator within the relativistic plane-wave impulse approximation. The RPR model was developed to describe photoinduced and electroinduced charged-kaon production off protons. We show how this elementary operator can be transformed in order to account for the production of neutral kaons from both protons and neutrons. The model results for kaon photoproduction from the deuteron compare favourably to the {sup 2}H({gamma},K)YN data published to date.

  7. X-ray diffraction using synchrotron radiation on the G.I.L.D.A. beam line at the E.S.R.F

    Energy Technology Data Exchange (ETDEWEB)

    Balerna, A. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Meneghini, C. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)]|[INFM, Genoa (Italy); Bordoni, S. [Rome Univ. `Tor Vergata` (Italy). Dip. di Fisica; Mobilio, S. [Rome Univ. III (Italy). Dip. di Fisica `E. Amaldi`

    1996-09-01

    The aim of this lecture is to make a short introduction on Synchrotron radiation, its history and main properties. The main components of a synchrotron radiation beam line will be described. The Italian beam line, General purpose Italian beam line Line for Diffraction and Absorption (G.I.L.D.A.) at the European Synchrotron Radiation Facility (E.S.R.F.) in Grenoble will be used as an example. The G.I.L.D.A. diffractometer will be described in detail reporting also some experimental results.

  8. Optics Measurements and Matching of TT2-TT10 Line for Injection of the LHC Beam in the SPS

    CERN Document Server

    Benedetto, E

    2008-01-01

    A well matched injection in the SPS is very important for preserving the emittance of the LHC beam. The paper presents the algorithms used for the analysis and the results of the 2007 optics measurements campaign done in the transfer line TT2-TT10 and in the SPS. The dispersion is computed by varying the beam momentum and recording the offsets at the BPMs, while the Twiss parameters and emittance measurements in TT2-TT10 are performed with beam profile monitors equipped with OTR screens. Finally, on the basis of such measurements, a betatron and dispersion matching of TT2-TT10 for injection in the SPS has been performed and successfully put in operation since October 2007.

  9. GEANT4 simulation of the ACE beam line : Measurement of the energy distribution of degraded Antiproton beam and the ToF signal of generated pions.

    CERN Document Server

    BRAHIMI, Nihel

    2014-01-01

    The present document describes my 8 weeks work project as a summer student at the AEgIS experiment under the supervision of Michael Doser and what i have learned during this period . It can be devided into three main tasks which are: Theoretical preparations concerning low energy antiproton physics. Learning the basic principles of GEANT4 simu- lation toolkit. Using GEANT4 platform to follow up the work of two technical students (Logan and Conrad) in designing an experiment (ACE beam line ) which aims at improving the methods of detect- ing matter-antimatter annihilations vertices at low energies in terms of resolution and accuracy using hybrid detectors .

  10. Violation of Bell’s inequality in neutral kaons system

    Indian Academy of Sciences (India)

    Manoj K Samal; Dipankar Home

    2002-08-01

    We show by general considerations that it is not possible to test violation of the existing versions of Bell’s inequality in entangled neutral kaons system using experimentally accessible thin regenerators. We point out the loophole in the recent argument (A Bramon and M Nowakowski, Phys. Rev. Lett. 83, 1 (1999)) that claimed such a test to be possible.

  11. Limits on Lorentz violation in neutral-Kaon decay

    NARCIS (Netherlands)

    Vos, K.K.; Wilschut, H. W.; Timmermans, R. G. E.

    2013-01-01

    The KLOE collaboration recently reported bounds on the directional dependence of the lifetime of the short-lived neutral kaon K_S with respect to the cosmic microwave background dipole anisotropy. We interpret their results in a general framework developed to probe Lorentz violation in the weak

  12. Exploration of Lorentz violation in neutral-kaon decay

    NARCIS (Netherlands)

    Vos, K.K.; Noordmans, J.P.; Wilschut, H. W.; Timmermans, R.G.E.

    2014-01-01

    The KLOE Collaboration recently reported bounds on the directional dependence of the lifetime of the short-lived neutral kaon K-S(0) with respect to the dipole anisotropy of the cosmic microwave background. We interpret their results in an effective field theory framework developed to probe the

  13. Bell inequality and CP violation in the neutral kaon system

    CERN Document Server

    Bertlmann, Reinhold A; Hiesmayr, B C

    2001-01-01

    For the entangled neutral kaon system we formulate a Bell inequality sensitive to CP violation in mixing. Via this Bell inequality we obtain a bound on the leptonic CP asymmetry which is violated by experimental data. Furthermore, we connect the Bell inequality with a decoherence approach and find a lower bound on the decoherence parameter which practically corresponds to Furry's hypothesis.

  14. Optimization of Experiment Detecting Kaon and Pion Internal Structure

    Science.gov (United States)

    Wacht, Jacob

    2016-09-01

    Pions and kaons are the lightest two-quark systems in Nature. Scientists believe that the rules governing the strong interaction are chirally, symmetric. If this were true, the pion would have no mass. The chiral symmetry is broken dynamically by quark-gluon interactions, giving the pion mass. The pion is thus seen as the key to confirm the mechanism that dynamically generates nearly all of the mass of hadrons and central to the effort to understand hadron structure. The most prominent observables are the meson form factors. Experiments are planned at the 12 GeV Jefferson Lab. An experiment aimed at shedding light on the kaon's internal structure is scheduled to run in 2017. The experimental setup has been optimized for detecting kaons, but it may allow for detecting pions between values of Q2 of 0.4 and 5.5 GeV2. Measurements of the separated pion cross section and exploratory extraction of the pion form factor from electroproduction at low Q2 could be compared to earlier e-pi scattering data, and thus help validating the method. At high Q2, these measurements provide the first L/T separated cross sections and could help guide planned dedicated pion experiments. I will present possible parasitic studies with the upcoming kaon experiment. This work was supported in part by NSF Grant PHY-1306227.

  15. Determination of Transverse Charge Density from Kaon Form Factor Data

    Science.gov (United States)

    Mejia-Ott, Johann; Horn, Tanja; Pegg, Ian; Mecholski, Nicholas; Carmignotto, Marco; Ali, Salina

    2016-09-01

    At the level of nucleons making up atomic nuclei, among subatomic particles made up of quarks, K-mesons or kaons represent the most simple hadronic system including the heavier strange quark, having a relatively elementary bound state of a quark and an anti-quark as its valence structure. Its electromagnetic structure is then parametrized by a single, dimensionless quantity known as the form factor, the two-dimensional Fourier transform of which yields the quantity of transverse charge density. Transverse charge density, in turn, provides a needed framework for the interpretation of form factors in terms of physical charge and magnetization, both with respect to the propagation of a fast-moving nucleon. To this is added the value of strange quarks in ultimately presenting a universal, process-independent description of nucleons, further augmenting the importance of studying the kaon's internal structure. The pressing character of such research questions directs the present paper, describing the first extraction of transverse charge density from electromagnetic kaon form factor data. The extraction is notably extended to form factor data at recently acquired higher energy levels, whose evaluation could permit more complete phenomenological models for kaon behavior to be proposed. This work was supported in part by NSF Grant PHY-1306227.

  16. Proton and kaon timelike form factors from BABAR

    CERN Document Server

    Serednyakov, S I

    2015-01-01

    The latest BABAR results on the proton and kaon timelike form factors (FF) are presented. The special emphasize is made on comparison of the spacelike and timelike FFs and the rise of the proton FF near threshold. The behavior of the cross section of e+e- annihilation into hadrons near the nucleon-antinucleon threshold is discussed.

  17. NA48 results on neutral kaon and hyperon rare decays

    Indian Academy of Sciences (India)

    Nicolò Cartiglia

    2004-03-01

    The NA48 Collaboration has performed an extensive program of kaon and hyperon rare decays using the data collected during the period 1997-2001. This program includes new tests of chiral perturbation theory, new measurements of the mass and $K_{S}$ lifetime and the possibility to measure the Cabibbo angle using $\\Xi$ beta decays.

  18. Performance of a superconducting magnet system operated in the Super Omega Muon beam line at J-PARC

    Energy Technology Data Exchange (ETDEWEB)

    Makida, Yasuhiro; Ikedo, Yutaka; Ogitsu, Toru; Shimomura, Koichiro; Miyake, Yasuhiro; Yoshida, Makoto; Adachi, Taihei; Kadono, Ryosuke; Kawamura, Naritoshi; Strasser, Patric; Koda, Akihiro; Fujimori, Hiroshi; Nishiyama, Kusuo; Ohhata, Hirokatsu; Okamura, Takahiro; Okada, Ryutaro [J-PARC, KEK, Shirakata 203-1, Tokai, Naka, Ibaraki (Japan); Orikasa, Tomofumi [Keihin Product Operations, Toshiba, Suehiro 2-4, Tsurumi, Yokohama (Japan)

    2014-01-29

    A superconducting magnet system, which is composed of an 8 m long solenoid for transportation and 12 short solenoids for focusing, has been developed for Muon Science Establishment facility of J-PARC. The transport solenoid is composed of a 6 m straight section connected to a 45 degree curved section at each end. Muons of various momenta and of both electric charges are transported through the solenoid inner bore with an effective diameter of 0.3 m, where 2 T magnetic field is induced. There are 12 focusing solenoids with an effective bore diameter of 0.6 m and a length of 0.35 m arranged on a straight line at suitable intervals. The maximum central field of each focusing solenoid is 0.66 T. All solenoid coils are cooled by GM cryocoolers through their own conductions. The magnet system has been installed into the beam line in the summer of 2012, and its performance has been checked. Beam commissioning has been carried out since October 2012. During beam operation, temperature rise over 6 K in the transport solenoid due to a nuclear heating from the muon production target is observed at beam intensity of about 300 kW.

  19. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Science.gov (United States)

    Huerta-Parajon, M.; Martinez-Ballarin, R.; Abad, E.

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 106 protons/cm2 s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  20. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Huerta-Parajon, M., E-mail: mhuerta@essbilbao.org; Martinez-Ballarin, R., E-mail: rmartinez@essbilbao.org; Abad, E., E-mail: eabad@essbilbao.org

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 10{sup 6} protons/cm{sup 2} s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  1. Direct Measurement of $A_{b}$ using Charged Kaons at the SLD Detector

    CERN Document Server

    Abe, K; Akagi, T; Akimoto, H; Allen, N J; Ash, William W; Aston, D; Baird, K G; Baltay, C; Band, H R; Barakat, M B; Bardon, O; Barklow, Timothy L; Bashindzhagian, G L; Bauer, J M; Bellodi, G; Benvenuti, Alberto C; Bilei, G M; Bisello, D; Blaylock, G; Bogart, J R; Bower, G R; Brau, J E; Breidenbach, M; Bugg, W M; Burke, D; Burnett, T H; Burrows, P N; Byrne, R M; Calcaterra, A; Calloway, D H; Camanzi, B; Carpinelli, M; Cassell, R; Castaldi, R; Castro, A; Cavalli-Sforza, M; Chou, A; Church, E; Cohn, H O; Coller, J A; Convery, M R; Cook, V; Cowan, R F; Coyne, D G; Crawford, G; Damerell, C J S; Danielson, M N; Daoudi, M; De Groot, N; Dell'Orso, R; Dervan, P J; De Sangro, R; Dima, M; Dong, D N; Doser, Michael; Dubois, R; Eisenstein, B I; Erofeeva, I; Eschenburg, V; Etzion, E; Fahey, S; Falciai, D; Fan, C; Fernández, J P; Fero, M J; Flood, K; Frey, R; Gifford, J A; Gillman, T; Gladding, G E; González, S; Goodman, E R; Hart, E L; Harton, J L; Hasuko, K; Hedges, S J; Hertzbach, S S; Hildreth, M D; Huber, J; Huffer, M E; Hughes, E W; Huynh, X; Hwang, H; Iwasaki, M; Jackson, D J; Jacques, P; Jaros, J A; Jiang, Z Y; Johnson, A S; Johnson, J R; Johnson, R A; Junk, T R; Kajikawa, R; Kalelkar, M S; Kamyshkov, Yu A; Kang, H J; Karliner, I; Kawahara, H; Kim, Y D; King, M E; King, R; Kofler, R R; Krishna, N M; Kroeger, R S; Langston, M; Lath, A; Leith, D W G S; Lia, V; Lin, C; Liu, M X; Liu, X; Loreti, M; Lu, A; Lynch, H L; Ma, J; Mahjouri, M; Mancinelli, G; Manly, S L; Mantovani, G C; Markiewicz, T W; Maruyama, T; Masuda, H; Mazzucato, E; McKemey, A K; Meadows, B T; Menegatti, G; Messner, R; Mockett, P M; Moffeit, K C; Moore, T B; Morii, M; Müller, D; Murzin, V S; Nagamine, T; Narita, S; Nauenberg, U; Neal, H A; Nussbaum, M; Oishi, N; Onoprienko, D V; Osborne, L S; Panvini, R S; Park, C H; Pavel, T J; Peruzzi, I; Piccolo, M; Piemontese, L; Pitts, K T; Plano, R J; Prepost, R; Prescott, C Y; Punkar, G D; Quigley, J; Ratcliff, B N; Reeves, T W; Reidy, J; Reinertsen, P L; Rensing, P E; Rochester, L S; Rowson, P C; Russell, J J; Saxton, O H; Schalk, T L; Schindler, R H; Schumm, B A; Schwiening, J; Sen, S; Serbo, V V; Shaevitz, M H; Shank, J T; Shapiro, G; Sherden, D J; Shmakov, K D; Simopoulos, C; Sinev, N B; Smith, S R; Smy, M B; Snyder, J A; Stängle, H; Stahl, A; Stamer, P E; Steiner, H; Steiner, R; Strauss, M G; Su, D; Suekane, F; Sugiyama, A; Suzuki, S; Swartz, M; Szumilo, A; Takahashi, T; Taylor, F E; Thom, J; Torrence, E; Toumbas, N K; Usher, T; Vannini, C; Vavra, J; Vella, E N; Venuti, J P; Verdier, R; Verdini, P G; Wagner, D L; Wagner, S R; Waite, A P; Walston, S; Watts, S J; Weidemann, A W; Weiss, E R; Whitaker, J S; White, S L; Wickens, F J; Williams, B; Williams, D C; Williams, S H; Willocq, S; Wilson, R J; Wisniewski, W J; Wittlin, J L; Woods, M; Word, G B; Wright, T R; Wyss, J; Yamamoto, R K; Yamartino, J M; Yang, X; Yashima, J; Yellin, S J; Young, C C; Yuta, H; Zapalac, G H; Zdarko, R W; Zhou, J

    1999-01-01

    We report a new measurement of A_b using data obtained by SLD in 1997-98. This measurement uses a vertex tag technique, where the selection of a b hemisphere is based on the reconstructed mass of the bottom hadron decay vertex. The method uses the 3D vertexing capabilities of SLD's CCD vertex detector and the small and stable SLC beams to obtain a high b-event tagging efficiency and purity of 78% and 97%, respectively. Charged kaons identified by the CRID detector provide an efficient quark-antiquark tag, with the analyzing power calibrated from the data. We obtain a preliminary result of A_b = 0.997

  2. Comparison of polarizations of inclusively produced lambdas and antilambdas by protons, antiprotons, and kaons

    Energy Technology Data Exchange (ETDEWEB)

    Melanson, H.L.

    1985-01-01

    The polarization of lambdas inclusively produced by kaons and protons, and antilambdas inclusively produced by antiprotons were measured at a beam momentum of 176 GeV/c, using a liquid hydrogen target. Data were collected in the range 0.0 < X/sub F/ < 0.8 and 0.2 < P/sub perpendicular/ < 1.5 GeV/c. Non-zero results were obtained for the reactions p + p ..-->.. ..lambda.. + X, anti/sup -/p + p ..-->.. anti-..lambda.. + X and K/sup -/ + p ..-->.. ..lambda.. + X. The polarizations for p ..-->.. ..lambda.., anti-p ..-->.. anti..lambda.. are equal in magnitude, with an average polarization of 0.063 +/- 0.022. The average polarization for K/sup -/ ..-->.. ..lambda.. is -0.419 +/- 0.029. All reactions are consistent with a linear dependence on P/sub perpendicular/.

  3. Simulation on the Pulsed Beam Transport for Injection Line of CYCIAE-10

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    1 Introduction The development of a 40 keV, 18 mA multi-cusp H- ion source and beam pulsing system have been completed successfully at CIAE. The pulsed H- beam with a repetition rate of 4.4 MHz and a pulse length of 9.6 ns has been obtained. In order to

  4. Transverse beam shape measurements of intense proton beams using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  5. Design, fabrication and testing of elliptical crystal bender for the EXAFS beam-line at INDUS-II synchrotron source

    Indian Academy of Sciences (India)

    N C Das; S N Jha; D Bhattacharyya; A K Poswal; A K Sinha; V K Mishra

    2004-10-01

    An extended X-ray absorption fine structure (EXAFS) beam-line for X-ray absorption studies using energy dispersive geometry and position sensitive detector is being developed for the INDUS-II synchrotron source. The optical design of the beam-line has been completed based on the working principle that a single crystal bent in the shape of an ellipse by a crystal bender would act as a dispersing as well as focusing element. The heart of the beam-line is the crystal bender which has been designed on the basis of the principle of four-point bending and has been fabricated indigenously. The crystal bender is capable of producing pre-defined elliptical curvature on a crystal surface by applying different couples at the two-ends of the crystal which has variable width along its length. The focusing property of the crystal bender has been tested using a laser source and has been compared with the theoretically simulated results.

  6. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    NARCIS (Netherlands)

    Huikari, J; Dendooven, P; Jokinen, A; Nieminen, A; Penttila, H; Perajarvi, K; Popov, A; Rinta-Antila, S; Aysto, J

    2004-01-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on a-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporati

  7. Design of a medium-energy beam-transport line with an anti-chopper for the JAERI/KEK project

    CERN Document Server

    Wang Sheng; Kato, T

    2002-01-01

    The medium-energy beam-transport line (MEBT) plays an important role in reducing beam loss in the JAERI/KEK project. A MEBT was designed two years ago, with good beam matching and lower beam loss. To further reduce beam loss during the transient time of the chopper to meet the new requirement from the DTL, a medium-energy beam-transport line with an anti-chopper has been designed. The 3.5 m long transport line consists of nine quadrupole magnets, three bunchers and four chopper/anti-chopper cavities. It accomplishes two tasks: matching the beam from the RFQ to the acceptance of the DTL and chopping the beam to produce gaps for injection into the rapid-cycling ring, which follows the linac. A RF Chopper and an anti-chopper have been adopted in the lattice, resulting in a clean chopping effect and no beam losses during the transient time. Details of the beam dynamics analysis are given

  8. Design of Air-Cooled Beam Dump for Extraction Line of PS Booster

    CERN Document Server

    Perillo-Marcone, A; Venturi, V; Antonakakis, T; Vlachoudis, V; Nowak, E; Mason, G; Battistin, M; Czapski, M; Sgobba, S

    2013-01-01

    A new beam dump has been designed, which withstands the future proton beam extracted from the Proton Syncrotron Booster (PSB) at CERN, consisting of up to 1E14 protons per pulse at 2 GeV after its upgrade in 2018/2019. In order to be able to efficiently release the deposited heat, the new dump will be made out of a single cylindrical block of a copper alloy and cooled by forced ventilation. In order to determine the energy density distribution deposited by the beam in the dump, Monte Carlo simulations were performed using FLUKA, and thermomechanical analyses carried out by importing the energy density into Ansys. In addition, CFD simulations of the airflow were carried out in order to accurately estimate the heat transfer convection coefficient on the surface of the dump. This paper describes the design process and highlights the constraints of integrating a new dump for increased beam power into the existing facility.

  9. Directed Energy Beam Jitter Mitigation Using the Line-of-Sight Reference Frame

    Science.gov (United States)

    2011-05-10

    solid state lasers. FELs allow 12 operators to change the beam wavelength to minimize losses due to absorption as the beam propagates through the...atmosphere. This is extremely important in the maritime environment in which absorption losses are a significant contributor to propagation losses...initially tuned using Ziegler -Nichols tuning rules based on critical gain and critical period. The controller was tuned for the for multiple frequency

  10. Upgrade to a programmable timing system for the KOMAC proton linac and multi-purpose beam lines

    Science.gov (United States)

    Song, Young-Gi

    2016-09-01

    The KOMAC facility consists of low-energy components, including a 50-keV ion source, a lowenergy beam transport (LEBT), a 3-MeV radio-frequency quadrupole (RFQ), and a 20-MeV drift tube linac (DTL), as well as high-energy components, including seven DTL tanks for the 100-MeV proton beam. The KOMAC includes ten beam lines, five for 20-MeV beams and five for 100-MeV beams. The peak beam current and the maximum beam duty are 20 mA and 24% for the 20-MeV linac and 20 mA and 8% for the 100-MeV linac, respectively. Four high-voltage convertor modulators are used. Each modulator drives two or three klystrons. The peak output power is 5.8 MW, and the average power is 520 kW with a duty of 9%. The pulse width and repetition rate are 1.5 ms and 60 Hz, respectively. Each component of the pulsed operation mode has a timing trigger signal with precision synchronization. A timing system for beam extraction and for diagnostic components is required to provide precise pulse signals synchronized with a 300-MHz RF reference frequency. In addition, the timing parameters should be capable of real-time changes in accordance with the beam power. The KOMAC timing system has been upgraded to a programmable Micro Research Finland (MRF) event timing system that is synchronized with the RF, AC main frequency and with the global positioning system (GPS) 1-PPS signal. The event timing system consists of an event generator (EVG) and an event receiver (EVR). The event timing system is integrated with the KOMAC control system by using experimental physics and industrial control system (EPICS) software. For preliminary hardware and software testing, a long operation test with a synchronization of 300-MHz RF reference and 60-Hz AC has been completed successfully. In this paper, we will describe the software implementation, the testing, and the installation of the new timing system.

  11. On-line measurements of proton beam current from a PET cyclotron using a thin aluminum foil

    Science.gov (United States)

    Ghithan, S.; do Carmo, S. J. C.; Ferreira Marques, R.; Fraga, F. A. F.; Simões, H.; Alves, F.; Crespo, P.

    2013-07-01

    The number of cyclotrons capable of accelerating protons to about 20 MeV is increasing throughout the world. Originally aiming at the production of positron emission tomography (PET) radionuclides, some of these facilities are equipped with several beam lines suitable for scientific research. Radiobiology, radiophysiology, and other dosimetric studies can be performed using these beam lines. In this work, we measured the Bragg peak of the protons from a PET cyclotron using a stacked target consisting of several aluminum foils interleaved with polyethylene sheets, readout by in-house made transimpedance electronics. The measured Bragg peak is consistent with simulations performed using the SRIM/TRIM simulation toolkit. Furthermore, we report on experimental results aiming at measuring proton beam currents down to 10 pA using a thin aluminum foil (20-μm-thick). The aluminum was chosen for this task because it is radiation hard, it has low density and low radiation activity, and finally because it is easily available at negligible cost. This method allows for calculating the dose delivered to a target during an irradiation with high efficiency, and with minimal proton energy loss and scattering.

  12. Overview of the Conceptual Design of the Future VENUS Neutron Imaging Beam Line at the Spallation Neutron Source

    Science.gov (United States)

    Bilheux, Hassina; Herwig, Ken; Keener, Scott; Davis, Larry

    VENUS (Versatile Neutron Imaging Beam line at the Spallation Neutron Source) will be a world-class neutron-imaging instrument that will uniquely utilize the Spallation Neutron Source (SNS) time-of-flight (TOF) capabilities to measure and characterize objects across several length scales (mm to μm). When completed, VENUS will provide academia, industry and government laboratories with the opportunity to advance scientific research in areas such as energy, materials, additive manufacturing, geosciences, transportation, engineering, plant physiology, biology, etc. It is anticipated that a good portion of the VENUS user community will have a strong engineering/industrial research focus. Installed at Beam line 10 (BL10), VENUS will be a 25-m neutron imaging facility with the capability to fully illuminate (i.e., umbra illumination) a 20 cm x 20 cm detector area. The design allows for a 28 cm x 28 cm field of view when using the penumbra to 80% of the full illumination flux. A sample position at 20 m will be implemented for magnification measurements. The optical components are comprised of a series of selected apertures, T0 and bandwidth choppers, beam scrapers, a fast shutter to limit sample activation, and flight tubes filled with Helium. Techniques such as energy selective, Bragg edge and epithermal imaging will be available at VENUS.

  13. Matrix:. AN Innovative Pixel Ionization Chamber for On-Line Beam Monitoring in Hadrontherapy

    Science.gov (United States)

    Braccini, S.; Pitta', G.; Donetti, M.; Cirio, R.; La Rosa, A.; Garella, M. A.; Giordanengo, S.; Marchetto, F.; Peroni, C.

    2006-04-01

    The control of intensity, position and shape of clinical beams are key issues in the treatment of tumours using hadron beams, especially in the case of active dose distribution systems. For this purpose an innovative pixel ionization chamber, named MATRIX, has been designed, constructed and tested. The chamber is conceived to be located very near the patient to precisely monitor the beam parameters used to verify the treatment planning specifications. MATRIX operates in air and is characterized by a 21 × 21 cm2 sensitive area subdivided in 1024 pixels of 6.5 × 6.5 mm2. To minimize the amount of material crossed by the beam, the anode is made of a 50 μm kapton foil, with a deposit of 17 μm copper on each side. A very sensitive electronics is used for the readout, based on a dedicated chip. In this paper the construction of the chamber and the very positive results of the first beam tests are described.

  14. Observation of Muon Neutrino Charged Current Events in an Off-Axis Horn-Focused Neutrino Beam Using the NOvA Prototype Detector

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Enrique Arrieta [Michigan State Univ., East Lansing, MI (United States)

    2014-01-01

    The NOνA is a long base-line neutrino oscillation experiment. It will study the oscillations between muon and electron neutrinos through the Earth. NOνA consists of two detectors separated by 810 km. Each detector will measure the electron neutrino content of the neutrino (NuMI) beam. Differences between the measurements will reveal details about the oscillation channel. The NOνA collaboration built a prototype detector on the surface at Fermilab in order to develop calibration, simulation, and reconstruction tools, using real data. This 220 ton detector is 110 mrad off the NuMI beam axis. This off-axis location allows the observation of neutrino interactions with energies around 2 GeV, where neutrinos come predominantly from charged kaon decays. During the period between October 2011 and April 2012, the prototype detector collected neutrino data from 1.67 × 1020 protons on target delivered by the NuMI beam. This analysis selected a number of candidate charged current muon neutrino events from the prototype data, which is 30% lower than predicted by the NOνA Monte Carlo simulation. The analysis suggests that the discrepancy comes from an over estimation of the neutrino flux in the Monte Carlo simulation, and in particular, from neutrinos generated in charged kaon decays. The ratio of measured divided by the simulated flux of muon neutrinos coming from charged kaon decays is: 0.70+0.108 -0.094. The NOνA collaboration may use the findings of this analysis to introduce a more accurate prediction of the neutrino flux produced by the NuMI beam in future Monte Carlo simulations.

  15. Demonstration of Current Profile Shaping using Double Dog-Leg Emittance Exchange Beam Line at Argonne Wakefield Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Gwanghui [Argonne, HEP; Cho, Moo-Hyun [POSTECH; Conde, Manoel [Argonne, HEP; Doran, Darrell [Argonne, HEP; Gai, Wei [Argonne, HEP; Jing, Chunguang [Euclid Techlabs, Solon; Kim, Kwang-Je [Argonne, HEP; Liu, Wanming [Argonne, HEP; Namkung, Won [POSTECH; Piot, Philippe [Northern Illinois U.; Power, John [Argonne, HEP; Sun, Yin-E [Argonne, HEP; Whiteford, Charles [Argonne, HEP; Wisniewski, Eric [Argonne, HEP; Zholents, Alexander [Argonne, HEP

    2016-06-01

    Emittance exchange (EEX) based longitudinal current profile shaping is the one of the promising current profile shaping technique. This method can generate high quality arbitrary current profiles under the ideal conditions. The double dog-leg EEX beam line was recently installed at the Argonne Wakefield Accelerator (AWA) to explore the shaping capability and confirm the quality of this method. To demonstrate the arbitrary current profile generation, several different transverse masks are applied to generate different final current profiles. The phase space slopes and the charge of incoming beam are varied to observe and suppress the aberrations on the ideal profile. We present current profile shaping results, aberrations on the shaped profile, and its suppression.

  16. Off-line production of a sup 7 Be radioactive ion beam

    CERN Document Server

    Gialanella, L; De Cesare, N; D'Onofrio, A; Romano, M; Campajola, L; Formicola, A; Fülöp, Z; Gyürky, G; Imbriani, G; Lubritto, C; Ordine, A; Roca, V; Rogalla, D; Rolfs, C; Russo, M; Sabbarese, C; Somorjai, E; Strieder, F; Terrasi, F; Trautvetter, H P

    2002-01-01

    A sup 7 Be ion beam of several particle pA at 8 MeV has been produced at the TTT3 tandem of the University 'Federico II' in Naples. The sup 7 Be nuclides were formed via the sup 7 Li(p,n) sup 7 Be reaction using a metallic Li target and an 11.4 MeV proton beam of 20 mu A intensity, delivered by the cyclotron in Debrecen. Methods of hot chemistry were used to extract the sup 7 Be nuclides from the Li matrix and to prepare the sup 7 Be cathodes for the ion sputter source of the tandem. Examples of sup 7 Be beam applications are given.

  17. Studies of the Strange Sea-Quarks Spin with Kaons

    Science.gov (United States)

    Benmokhtar, Fatiha; Voloshin, Andrew; Goodwill, Justin; Lendacky, Andrew

    2017-01-01

    It is well known that quarks and gluons give the substructure to the nucleons. and understanding of the spin structure of the nucleon in terms of quarks and gluons has been the goal of intense investigations during the last decades. The determination of strangeness is challenging and the only way of determining the strange distribution accurately from data is to improve the semi-inclusive information. This talk is focused on the determination of the strange sea contribution to the nucleon spin through the pseudo-scalar method using semi-inclusive Kaon detection technique with CLAS12 at Jefferson Lab. A Ring Imaging CHerenkov (RICH) detector is under construction and will be used for pion-kaon-proton separation. National Science Foundation #1615067.

  18. Valence-quark distribution functions in the kaon and pion

    CERN Document Server

    Chen, Chen; Roberts, Craig D; Wan, Shaolong; Zong, Hong-Shi

    2016-01-01

    We describe expressions for pion and kaon dressed-quark distribution functions that incorporate contributions from gluons which bind quarks into these mesons and hence overcome a flaw of the commonly used handbag approximation. The distributions therewith obtained are purely valence in character, ensuring that dressed-quarks carry all a meson's momentum at a characteristic hadronic scale and vanishing as $(1-x)^2$ when Bjorken-$x\\to 1$. Comparing such distributions within the pion and kaon, it is apparent that the size of SU(3)-flavour symmetry breaking in meson parton distribution functions is modulated by the flavour dependence of dynamical chiral symmetry breaking. Corrections to these leading-order formulae may be divided into two classes, responsible for shifting dressed-quark momentum into glue and sea-quarks. Working with available empirical information, we build an algebraic framework that is capable of expressing the principal impact of both classes of corrections. This enables a realistic comparison...

  19. Classical Illustrations of CP Violation in Kaon Decays

    CERN Document Server

    Rosner, Jonathan L; Rosner, Jonathan L.; Slezak, Scott A.

    2001-01-01

    It is easy to construct classical 2-state systems illustrating the behavior of the short-lived and long-lived neutral $K$ mesons in the limit of CP conservation. The emulation of CP violation is more tricky, but is provided by the two-dimensional motion of a Foucault pendulum. Analogies are drawn between the pendulum and observables in neutral kaon decays. An emulation of CP- and CPT-violation using electric circuits is also discussed.

  20. Kaon Photoproduction Near Threshold in Six Isospin Channels Revisited

    Science.gov (United States)

    Mart, T.

    2016-08-01

    In this talk I review the progress achieved in the investigation of kaon photoproduction on the nucleon near the production threshold. This investigation has been performed by using the so-called isobar model, which makes use of Feynman diagrams for the background terms and the Breit-Wigner multipoles for the resonance terms. The future prospect as well as application of this model in the hadronic sector are also briefly discussed.

  1. Three-prong $\\tau$ decays with charged kaons

    CERN Document Server

    Barate, R; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Nief, J Y; Pietrzyk, B; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Delfino, M C; Fernández, E; Fernández-Bosman, M; Garrido, L; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Padilla, C; Park, I C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Alemany, R; Becker, U; Bazarko, A O; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Hagelberg, R; Hansen, J B; Harvey, J; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Lutters, G; Mato, P; Minten, Adolf G; Moneta, L; Pacheco, A; Pusztaszeri, J F; Ranjard, F; Rizzo, G; Rolandi, Luigi; Rousseau, D; Schlatter, W D; Schmitt, M; Schneider, O; Tejessy, W; Tomalin, I R; Wachsmuth, H W; Wagner, A; Ajaltouni, Ziad J; Barrès, A; Boyer, C; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rosnet, P; Rossignol, J M; Fearnley, Tom; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Rougé, A; Rumpf, M; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Casper, David William; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Knowles, I G; Lynch, J G; O'Shea, V; Raine, C; Scarr, J M; Smith, K; Teixeira-Dias, P; Thompson, A S; Thomson, E; Thomson, F; Turnbull, R M; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Moutoussi, A; Nash, J; Sedgbeer, J K; Spagnolo, P; Stacey, A M; Williams, M D; Ghete, V M; Girtler, P; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Sloan, Terence; Williams, M I; Galla, A; Giehl, I; Greene, A M; Hoffmann, C; Jakobs, K; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Bujosa, G; Carr, J; Coyle, P; Diaconu, C A; Etienne, F; Konstantinidis, N P; Leroy, O; Motsch, F; Payre, P; Talby, M; Sadouki, A; Thulasidas, M; Trabelsi, K; Aleppo, M; Antonelli, M; Ragusa, F; Berlich, R; Blum, Walter; Büscher, V; Dietl, H; Ganis, G; Gotzhein, C; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Stenzel, H; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Chen, S; Choi, Y; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Höcker, A; Jacholkowska, A; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Nikolic, I A; Schune, M H; Simion, S; Tournefier, E; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Sanguinetti, G; Sciabà, A; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Bryant, L M; Chambers, J T; Gao, Y; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Maley, P; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Boswell, R; Brew, C A J; Cartwright, S L; Combley, F; Kelly, M S; Lehto, M H; Newton, W M; Reeve, J; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Grupen, Claus; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Charles, E; Elmer, P; Ferguson, D P S; González, S; Greening, T C; Hayes, O J; Hu, H; Jin, S; McNamara, P A; Nachtman, J M; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Walsh, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    1998-01-01

    Final states with charged kaons in three-prong $\\tau$ decays are studied by exploiting the particle identification from the dE/dx measurement. The results are based on a sample of about $1.6\\times 10^{5}$ detected $\\tau$ pairs collected with the ALEPH detector between 1991 and 1995 around the Z peak. The following branching ratios have been measured: $B(\\tau^{-}~\\rightarrow~K^{-}K^{+}\\pi^{-}\

  2. Light-front model of the kaon electromagnetic current

    CERN Document Server

    Pacheco-Bicudo-Cabral de Melo, J; Frederico, T; Tomio, Lauro

    2003-01-01

    The electromagnetic form factor is extracted from both components of the electromagnetic current: J(plus) and J(minus) with a pseudo-scalar coupling of the quarks to the kaon. In the case of J(plus) there is no pair term contribution in the Drell-Yan frame. However, J(minus) component of the electromagnetic current the pair term contribution is different from zero and is necessary include it to preserve the rotational symmetry of the current.

  3. Surface Tension between Kaon Condensate and Normal Nuclear Matter Phase

    OpenAIRE

    Christiansen, Michael B.; Glendenning, Norman K.; Schaffner-Bielich, Jurgen

    2000-01-01

    We calculate for the first time the surface tension and curvature coefficient of a first order phase transition between two possible phases of cold nuclear matter, a normal nuclear matter phase in equilibrium with a kaon condensed phase, at densities a few times the saturation density. We find the surface tension is proportional to the difference in energy density between the two phases squared. Furthermore, we show the consequences for the geometrical structures of the mixed phase region in ...

  4. Kaon decay studies at CERN SPS in the last decades

    Science.gov (United States)

    Ceccucci, A.; Goudzovski, E.; Kekelidze, V.; Madigozhin, D.; Potrebenikov, I.

    2016-07-01

    This review summarizes the kaon experimental results obtained in the last 15 years on the basis of data collected on the SPS in CERN with a participance of JINR physicists. These results contribute essentially into the Standard Model checks and search for its extension, fundamental symmetry violations and low energy strong interactions theory development. A progress in the experimental technique and prospects for the future results are also discussed.

  5. First results of the INSIDE in-beam PET scanner for the on-line monitoring of particle therapy treatments

    Science.gov (United States)

    Piliero, M. A.; Belcari, N.; Bisogni, M. G.; Camarlinghi, N.; Cerello, P.; Coli, S.; Del Guerra, A.; Ferrero, V.; Fiorina, E.; Giraudo, G.; Kostara, E.; Morrocchi, M.; Pennazio, F.; Peroni, C.; Pirrone, G.; Rivetti, A.; Rolo, M. D.; Rosso, V.; Sportelli, G.; Wheadon, R.

    2016-12-01

    Quality assessment of particle therapy treatments by means of PET systems has been carried out since late `90 and it is one of the most promising in-vivo non invasive monitoring techniques employed clinically. It can be performed with a diagnostic PET scanners installed outside the treatment room (off-line monitoring) or inside the treatment room (in-room monitoring). However the most efficient way is by integrating a PET scanner with the treatment delivery system (on-line monitoring) so that the biological wash out and the patient repositioning errors are minimized. In this work we present the performance of the in-beam PET scanner developed within the INSIDE project. The INSIDE PET scanner is made of two planar heads, 10 cm wide (transaxially) and 25 cm long (axially), composed of pixellated LFS crystals coupled to Hamamatsu MPPCs. Custom designed Front-End Electronics (FE) and Data AcQuisition (DAQ) systems allow an on-line reconstruction of PET images from separated in-spill and inter-spill data sets. The INSIDE PET scanner has been recently delivered at the CNAO (Pavia, Italy) hadrontherapy facility and the first experimental measurements have been carried out. Homogeneous PMMA phantoms and PMMA phantoms with small air and bone inserts were irradiated with monoenergetic clinical proton beams. The activity range was evaluated at various benchmark positions within the field of view to assess the homogeneity of response of the PET system. Repeated irradiations of PMMA phantoms with clinical spread out Bragg peak proton beams were performed to evaluate the reproducibility of the PET signal. The results found in this work show that the response of the INSIDE PET scanner is independent of the position within the radiation field. Results also show the capability of the INSIDE PET scanner to distinguish variations of the activity range due to small tissue inhomogeneities. Finally, the reproducibility of the activity range measurement was within 1 mm.

  6. Bose-Einstein Correlations of Charged and Neutral Kaons in Deep Inelastic Scattering at HERA

    CERN Document Server

    Chekanov, S; Magill, S; Musgrave, B; Nicholass, D; Repond, J; Yoshida, R; Mattingly, M C K; Jechow, M; Pavel, N; Yagues-Molina, A G; Antonelli, S; Antonioli, P; Bari, G; Basile, M; Bellagamba, L; Bindi, M; Boscherini, D; Bruni, A; Bruni, G; Cifarelli, L; Cindolo, F; Contin, A; Corradi, M; De Pasquale, S; Iacobucci, G; Margotti, A; Nania, R; Polini, A; Sartorelli, G; Zichichi, A; Bartsch, D; Brock, I; Goers, S; Hartmann, H; Hilger, E; Jakob, H P; Jüngst, M; Kind, O M; Nuncio-Quiroz, A E; Paul, E; Renner, R; Samson, U; Schonberg, V; Shehzadi, R; Wlasenko, M; Brook, N H; Heath, G P; Morris, J D; Namsoo, T; Capua, M; Fazio, S; Mastroberardino, A; Schioppa, M; Susinno, G; Tassi, E; Kim, J Y; Ma, K J; Ibrahim, Z A; Kamaluddin, B; Wan-Abdullah, W A T; Ning, Y; Ren, Z; Sciulli, F; Chwastowski, J; Eskreys, A; Figiel, J; Galas, A; Gil, M; Olkiewicz, K; Stopa, P; Zawiejski, L; Adamczyk, L; Bold, T; Grabowska-Bold, I; Kisielewska, D; Lukasik, J; Przybycien, M; Suszycki, L; Kotanski, A; Slominski, W; Adler, V; Behrens, U; Bloch, I; Blohm, C; Bonato, A; Borras, K; Ciesielski, R; Coppola, N; Dossanov, A; Drugakov, V; Fourletova, J; Geiser, A; Gladkov, D; Göttlicher, P; Grebenyuk, J; Gregor, I; Haas, T; Hain, W; Horn, C; Huttmann, A; Kahle, B; Katkov, I I; Klein, U; Kötz, U; Kowalski, H; Lobodzinska, E; Löhr, B; Mankel, R; Melzer-Pellmann, I A; Miglioranzi, S; Montanari, A; Notz, D; Rinaldi, L; Roloff, P; Rubinsky, I; Santamarta, R; Schneekloth, U; Spiridonov, A; Stadie, H; Szuba, D; Szuba, J; Theedt, T; Wolf, G; Wrona, K; Youngman, C; Zeuner, W; Lohmann, W; Schlenstedt, S; Barbagli, G; Gallo, E; Pelfer, P G; Bamberger, A; Dobur, D; Karstens, F; Vlasov, N N; Bussey, P J; Doyle, A T; Dunne, W; Ferrando, J; Forrest, M; Saxon, D H; Skillicorn, I O; Gialas, I; Papageorgiu, K; Gosau, T; Holm, U; Klanner, R; Lohrmann, E; Salehi, H; Schleper, P; Schörner-Sadenius, T; Sztuk, J; Wichmann, K; Wick, K; Foudas, C; Fry, C; Long, K R; Tapper, A D; Kataoka, M; Matsumoto, T; Nagano, K; Tokushuku, K; Yamada, S; Yamazaki, Y; Barakbaev, A N; Boos, E G; Pokrovskiy, N S; Zhautykov, B O; Aushev, V; Son, D; De Favereau, J; Piotrzkowski, K; Barreiro, F; Glasman, C; Jiménez, M; Labarga, L; Del Peso, J; Ron, E; Soares, M; Terron, J; Zambrana, M; Corriveau, F; Liu, C; Walsh, R; Zhou, C; Tsurugai, T; Antonov, A; Dolgoshein, B A; Sosnovtsev, V; Stifutkin, A; Suchkov, S; Dementiev, R K; Ermolov, P F; Gladilin, L K; Khein, L A; Korzhavina, I A; Kuzmin, V A; Levchenko, B B; Lukina, O Yu; Proskuryakov, A S; Shcheglova, L M; Zotkin, D S; Zotkin, S A; Abt, I; Büttner, C; Caldwell, A; Kollar, D; Schmidke, W B; Sutiak, J; Grigorescu, G; Keramidas, A; Koffeman, E; Kooijman, P; Pellegrino, A; Tiecke, H; Vázquez, M; Wiggers, L; Brümmer, N; Bylsma, B; Durkin, L S; Lee, A; Ling, T Y; Allfrey, P D; Bell, M A; Cooper-Sarkar, A M; Cottrell, A; Devenish, R C E; Foster, B; Korcsak-Gorzo, K; Patel, S; Roberfroid, V; Robertson, A; Straub, P B; Uribe-Estrada, C; Walczak, R; Bellan, P; Bertolin, A; Brugnera, R; Carlin, R; Dal Corso, F; Dusini, S; Garfagnini, A; Limentani, S; Longhin, A; Stanco, L; Turcato, M; Oh, B Y; Raval, A; Ukleja, J; Whitmore, J J; Iga, Y; D'Agostini, G; Marini, G; Nigro, A; Cole, J E; Hart, J C; Abramowicz, H; Gabareen, A; Ingbir, R; Kananov, S; Levy, A; Kuze, M; Maeda, J; Hori, R; Kagawa, S; Okazaki, N; Shimizu, S; Tawara, T; Hamatsu, R; Kaji, H; Kitamura, S; Ota, O; Ri, Y D; Ferrero, M I; Monaco, V; Sacchi, R; Solano, A; Arneodo, M; Ruspa, M; Fourletov, S; Martin, J F; Boutle, S K; Butterworth, J M; Gwenlan, C; Jones, T W; Loizides, J H; Sutton, M R; Wing, M; Brzozowska, B; Ciborowski, J; Grzelak, G; Kulinski, P; Luzniak, P; Malka, J; Nowak, R J; Pawlak, J M; Tymieniecka, T; Ukleja, A; Zarnecki, A F; Adamus, M; Plucinsky, P P; Eisenberg, Y; Giller, I; Hochman, D; Karshon, U; Rosin, M; Brownson, E; Danielson, T; Everett, A; Kcira, D; Reeder, D D; Ryan, P; Savin, A A; Smith, W H; Wolfe, H; Bhadra, S; Catterall, C D; Cui, Y; Hartner, G; Menary, S; Noor, U; Standage, J; Whyte, J

    2007-01-01

    Bose-Einstein correlations of charged and neutral kaons have been measured in e+-p deep inelastic scattering with an integrated luminosity of 121 pb-1 using the ZEUS detector at HERA. The two-particle correlation function was studied as a function of the four-momentum difference of the kaon pairs, Q_12=sqrt{-(p_1-p_2)^2}, assuming a Gaussian shape for the particle source. The values of the radius of the production volume, r, and of the correlation strength, lambda, were obtained for both neutral and charged kaons. The radii for charged and neutral kaons are similar and are consistent with those obtained at LEP.

  7. CP violation and Kaon weak matrix elements from Lattice QCD

    CERN Document Server

    Garron, Nicolas

    2015-01-01

    In this short review, I present the recent lattice computations of kaon weak matrix elements relevant to $K \\to \\pi\\pi$ decays and neutral kaon mixing. These matrix elements are key to the theoretical determination of the CP violation parameters $\\epsilon$ and $\\epsilon'$ . Impressive progress have been achieved recently, in particular the first realistic computation of $\\epsilon'/\\epsilon$ with physical kinematics has been reported in [1]. The novelty is the $\\Delta I = 1/2$ channel, whereas the $\\Delta I = 3/2$ contribution is now computed at several values of the lattice spacing and extrapolated to the continuum limit. I will also present the status of $B_K$ and discuss its error budget, with a particular emphasis on the perturbative error. Finally I will review the matrix elements of neutral kaon mixing beyond the standard model and will argue that the discrepancy observed by different collaborations could be explained by the renormalisation procedure of the relevant four-quark operators.

  8. Consistent Probabilistic Description of the Neutral Kaon System

    CERN Document Server

    Bernabeu, J; Villanueva-Perez, P

    2013-01-01

    The neutral Kaon system has both CP violation in the mass matrix and a non-vanishing lifetime difference in the width matrix. This leads to an effective Hamiltonian which is not a normal operator, with incompatible (non-commuting) masses and widths. In the Weisskopf-Wigner Approach (WWA), by diagonalizing the entire Hamiltonian, the unphysical non-orthogonal "stationary" states $K_{L,S}$ are obtained. These states have complex eigenvalues whose real (imaginary) part does not coincide with the eigenvalues of the mass (width) matrix. In this work we describe the system as an open Lindblad-type quantum mechanical system due to Kaon decays. This approach, in terms of density matrices for initial and final states, provides a consistent probabilistic description, avoiding the standard problems because the width matrix becomes a composite operator not included in the Hamiltonian. We consider the dominant-decay channel to two pions, so that one of the Kaon states with definite lifetime becomes stable. This new approa...

  9. Identification of dental root canals and their medial line from micro-CT and cone-beam CT records

    Directory of Open Access Journals (Sweden)

    Benyó Balázs

    2012-10-01

    Full Text Available Abstract Background Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenges. Accurate shape information of the root canals may also be used by manufacturers of endodontic instruments in order to make more efficient clinical tools. Method Novel image processing procedures dedicated to the automated detection of the medial axis of the root canal from dental micro-CT and cone-beam CT records are developed. For micro-CT, the 3D model of the root canal is built up from several hundred parallel cross sections, using image enhancement, histogram based fuzzy c-means clustering, center point detection in the segmented slice, three dimensional inner surface reconstruction, and potential field driven curve skeleton extraction in three dimensions. Cone-beam CT records are processed with image enhancement filters and fuzzy chain based regional segmentation, followed by the reconstruction of the root canal surface and detecting its skeleton via a mesh contraction algorithm. Results The proposed medial line identification and root canal detection algorithms are validated on clinical data sets. 25 micro-CT and 36 cone-beam-CT records are used in the validation procedure. The overall success rate of the automatic dental root canal identification was about 92% in both procedures. The algorithms proved to be accurate enough for endodontic therapy planning. Conclusions Accurate medial line identification and shape detection algorithms of dental root canal have been developed. Different procedures are defined for micro-CT and cone-beam CT records. The automated execution of the subsequent processing steps allows easy application of the algorithms in the dental care. The output data of the image processing procedures

  10. Perturbation-minimized triangular bunch for high-transformer ratio using a double dogleg emittance exchange beam line

    Science.gov (United States)

    Ha, G.; Cho, M. H.; Gai, W.; Kim, K.-J.; Namkung, W.; Power, J. G.

    2016-12-01

    The longitudinal shape, i.e., the current profile, of an electron bunch determines the transformer ratio in a collinear wakefield accelerator and thus methods are sought to control the longitudinal bunch shape. The emittance exchange (EEX) appears to be promising for creating a precisely controlled longitudinal bunch shapes. The longitudinal shape is perturbed by two sources: higher-order terms in the beam line optics and collective effects and these perturbations can lead to a significant drop of the transformer ratio. In this paper, we analytically and numerically investigate the perturbation to an ideal triangular longitudinal bunch shape and propose methods to minimize it.

  11. Reprint of: Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    Energy Technology Data Exchange (ETDEWEB)

    Pan, R., E-mail: rui.pan@stfc.ac.uk [Accelerator Science and Technology Centre, Science and Technology Facilities Council, Darebsury Laboratory, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); School of Engineering, Physics and Mathematics, University of Dundee, Nethergate, Dundee DD1 4HN (United Kingdom); Jamison, S.P. [Accelerator Science and Technology Centre, Science and Technology Facilities Council, Darebsury Laboratory, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); Lefevre, T. [CERN, CH-1211 Geneva 23 (Switzerland); Gillespie, W.A. [School of Engineering, Physics and Mathematics, University of Dundee, Nethergate, Dundee DD1 4HN (United Kingdom)

    2016-09-11

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding (EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  12. Reprint of: Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    Science.gov (United States)

    Pan, R.; Jamison, S. P.; Lefevre, T.; Gillespie, W. A.

    2016-09-01

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding (EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  13. Beam Losses in the Extraction Line of a TeV E+ E- Linear Collider With a 20-Mrad Crossing Angle

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, A.; /Uppsala U.; Nosochkov, Y.; /SLAC

    2006-03-29

    In this paper, we perform a detailed study of the power losses along the postcollision extraction line of a TeV e+e- collider with a crossing angle of 20 mrad between the beams at the interaction point. Five cases are considered here: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam-beam effects at the interaction point lead to an emittance growth for the outgoing beams, as well as to the production of beamstrahlung photons and e+e- pairs. The power losses along the 20 mrad extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the e+e- coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular o set at the interaction point.

  14. Design of a high-current low-energy beam transport line for an intense D-T/D-D neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Xiaolong, E-mail: luxl@lzu.edu.cn [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Wang, Junrun [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Zhang, Yu; Li, Jianyi; Xia, Li; Zhang, Jie; Ding, Yanyan; Jiang, Bing; Huang, Zhiwu; Ma, Zhanwen; Wei, Zheng [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Qian, Xiangping; Xu, Dapeng; Lan, Changlin [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Yao, Zeen, E-mail: zeyao@lzu.edu.cn [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou 730000 (China)

    2016-03-01

    An intense D-T/D-D neutron generator is currently being developed at the Lanzhou University. The Cockcroft–Walton accelerator, as a part of the neutron generator, will be used to accelerate and transport the high-current low-energy beam from the duoplasmatron ion source to the rotating target. The design of a high-current low-energy beam transport (LEBT) line and the dynamics simulations of the mixed beam were carried out using the TRACK code. The results illustrate that the designed beam line facilitates smooth transportation of a deuteron beam of 40 mA, and the number of undesired ions can be reduced effectively using two apertures.

  15. Direct Measurements of A_b and A_c using Vertex/Kaon Charge Tags at SLD

    CERN Document Server

    Abe, K; Adam, I; Akimoto, H; Aston, D; Baird, K G; Baltay, C; Band, H R; Barklow, T L; Bauer, J M; Bellodi, G; Berger, R; Blaylock, G; Bogart, J R; Bower, G R; Brau, J E; Breidenbach, M; Bugg, W M; Burke, D; Burnett, T H; Burrows, P N; Calcaterra, A; Cassell, R; Chou, A; Cohn, H O; Coller, J A; Convery, M R; Cook, V; Cowan, R F; Crawford, G; Damerell, C J S; Daoudi, M; Dasu, S; De Groot, N; De Sangro, R; Dong, D N; Doser, Michael; Dubois, R; Erofeeva, I; Eschenburg, V; Etzion, E; Fahey, S; Falciai, D; Fernández, J P; Flood, K; Frey, R; Hart, E L; Hasuko, K; Hertzbach, S S; Huffer, M E; Huynh, X; Iwasaki, M; Jackson, D J; Jacques, P; Jaros, J A; Jiang, Z Y; Johnson, A S; Johnson, J R; Kajikawa, R; Kalelkar, M; Kang, H J; Kofler, R R; Kroeger, R S; Langston, M; Leith, D W G S; Lia, V; Lin, C; Mancinelli, G; Manly, S; Mantovani, G C; Markiewicz, T W; Maruyama, T; McKemey, A K; Messner, R; Moffeit, K C; Moore, T B; Morii, M; Müller, D; Murzin, V; Narita, S; Nauenberg, U; Neal, H; Nesom, G; Oishi, N; Onoprienko, D; Osborne, L S; Panvini, R S; Park, C H; Peruzzi, I; Piccolo, M; Piemontese, L; Plano, R J; Prepost, R; Prescott, C Y; Ratcliff, B N; Reidy, J; Reinertsen, P L; Rochester, L S; Rowson, P C; Russell, J J; Saxton, O H; Schalk, T; Schumm, B A; Schwiening, J; Serbo, V V; Shapiro, G; Sinev, N B; Snyder, J A; Stängle, H; Stahl, A; Stamer, P; Steiner, H; Su, D; Suekane, F; Sugiyama, A; Suzuki, A; Swartz, M; Taylor, F E; Thom, J; Torrence, E; Usher, T; Vavra, J; Verdier, R; Wagner, D L; Waite, A P; Walston, S; Weidemann, A W; Weiss, E R; Whitaker, J S; Williams, S H; Willocq, S; Wilson, R J; Wisniewski, W J; Wittlin, J L; Woods, M; Wright, T R; Yamamoto, R K; Yashima, J; Yellin, S J; Young, C C; Yuta, H

    2004-01-01

    Exploiting the manipulation of the SLC electron-beam polarization, we present precise direct measurements of the parity violation parameters A_c and A_b in the Z boson - c quark and Z boson - b quark coupling. Quark/antiquark discrimination is accomplished via a unique algorithm that takes advantage of the precise SLD CCD vertex detector, employing the net charge of displaced vertices as well as the charge of kaons that emanate from those vertices. From the 1996-98 sample of 400,000 Z decays, produced with an average beam polarization of 73.4%, we find A_c = 0.673 +/- 0.029 (stat.) +/- 0.023 (syst.) and A_b = 0.919 +/- 0.018 (stat.) +/- 0.017 (syst.).

  16. Development of a New RF Finger concept for vacuum beam line interconnections

    CERN Document Server

    Garion, C; Rambeau, H

    2012-01-01

    RF contact fingers are primarily used as a transition element to absorb the thermal expansion of vacuum chambers during bake-out and also to compensate for mechanical tolerances. They have to carry the beam image current to avoid the generation of Higher Order Modes and to reduce beam impedances. They are usually made out of copper beryllium thin sheets and are therefore very fragile and critical components. In this paper, a robust design based on a deformable finger concept is proposed. It allows the compensation of large longitudinal movements and also defaults such as transverse offset, twist or bending. The concept of this new RF fingers is first explained, then the design of the component is presented. The mechanical study based on a highly non-linear Finite Element model is shown as well as preliminary tests, including fatigue assessment, carried out on prototypes.

  17. Tertiary particle production and target optimization of the H2 beam line in the SPS North Area

    CERN Document Server

    AUTHOR|(CDS)2079540; Tellander, Felix; CERN. Geneva. ATS Department

    2016-01-01

    In this note, the tertiary particle yield from secondary targets of different materials placed at the ‘filter’ position of the H2 beam line of SPS North Area are presented. The production is studied for secondary beams of different momenta in the range of 50-250 GeV/c. More specifically, we studied six different targets: two copper cylinders with a radius of 40 mm and lengths of 100 and 300 mm, one solid tungsten cylinder with a radius of 40 mm and a length of 150 mm and three polyethylene cylinders with radius of 40 mm and lengths of 550, 700 and 1000 mm. Eight different momenta of the secondary beam (50, 60, 70, 100, 120, 150, 200 and 250 GeV/c) as well as two different physics lists (QGSP_BIC and FTFP_BERT) have been extensively studied. The purpose of this study is (a) to optimize (using the appropriate filter target) the particle production from the secondary targets as demanded by the experiments (b) investigate the proton production (with respect to the pion production) in the produced tertiary bea...

  18. Analysis of the eigenvalue equation of the FEL amplifier with axisymmetric electron beam and diaphragm focusing line

    Science.gov (United States)

    Saldin, E. L.; Schneidmiller, E. A.; Yurkov, M. V.

    1996-02-01

    The paper presents analysis of the eigenvalue problem of the FEL amplifier with axisymmetric electron beam and diaphragm focusing line. This novel type of an FEL amplifier has perspective to be used for applications where high average and peak radiation power is required [E.L. Saldin et al., Nucl. Instr. and meth. A 361 (1995) 317; these Proceedings, Nucl. Instr. and Meth. 375 (1996) 389; Nucl. Instr. and Meth. A 361 (1995) 101]. An FEL model is discussed wherein diffraction effects, space charge fields and energy spread of electrons in the beam are taken into account. To take into account diffraction effects at the diaphragms we apply the rigorous impedance boundary conditions proposed by Veinstein. The rigorous solutions of the eigenvalue problem have been found for the stepped electron beam profile. Analytical expressions for eigenfunctions of active open waveguide and formulae of their expansion in the eigenfunctions of passive open waveguide, are derived, too. Asymptotic behaviour of the obtained solutions is studied in details.

  19. Laser Plasma Instability (LPI) Driven Light Scattering Measurements with 44 beam-lines of Nike KrF Laser^*

    Science.gov (United States)

    Oh, J.; Weaver, J. L.; Kehne, D. M.; Phillips, L. S.; Obenschain, S. P.; Serlin, V.; McLean, E. A.; Lehmberg, R. H.; Manka, C. K.

    2009-11-01

    With short wavelength (248 nm), large bandwidth (˜1 THz), and ISI beam smoothing, Nike KrF laser provides unique opportunities of LPI research for direct-drive inertial confinement fusion. Previous experiments at intensities (10^15˜10^16 W/cm^2) exceeded two-plasmon decay (TPD) instability threshold using 12 beam-lines of Nike laser.^a,b For further experiments to study LPI excitation in bigger plasma volumes, 44 Nike main beams have been used to produce plasmas with total laser energies up to 1 kJ of ˜350 psec FWHM pulses. This talk will present results of the recent LPI experiment focusing on light emission data in spectral ranges relevant to the Raman (SRS) and TPD instabilities. The primary diagnostics were time-resolved spectrometers with an absolute-intensity-calibrated photodiode array in (0.4˜0.8)φ0 and a streak camera near 0.5φ0. Blackbody temperature and expansion speed measurements of the plasmas were also made. The experiment was conducted at laser intensities of (1˜4)x10^15 W/cm^2 on solid planar CH targets. ^a J. L. Weaver, et al, NO4.14, APS DPP (2008) ^b J. Oh, et al, NO4.15, APS DPP (2008) * Work supported by DoE/NNSA and performed at Naval Research Laboratory.

  20. The covariant description of field lines: application to linked beams of light

    CERN Document Server

    van Enk, S J

    2013-01-01

    The concept of electric and magnetic field lines is intrinsically non-relativistic. Nonetheless, for certain types of fields satisfying certain {\\em geometric} properties, field lines can be defined covariantly. More precisely, two Lorentz-invariant 2D surfaces in spacetime can be defined such that magnetic and electric field lines are determined, for any observer, by the intersection of those surfaces with spacelike hyperplanes. An instance of this type of field is constituted by the so-called Hopf-Ranada solutions of the source-free Maxwell equations, which have been studied because of their interesting topological properties, namely, linkage of their field lines. In order to describe both geometric and topological properties in a succinct manner, we employ the tools of Geometric Algebra (aka Clifford Algebra) and use the Clebsch representation for the vector potential as well as the Euler representation for both magnetic and electric fields. This description is easily made covariant, thus allowing us to de...

  1. SHyPIE: a new source for on-line production of multicharged radioactive condensable ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Lecesne, N.; Foury, P.; Gaubert, G.; Huguet, Y.; Jardin, P.; Leroy, R.; Lewitowicz, M.; Marry, C.; Maunoury, L.; Pacquet, J.Y.; Robert, E.; Saint-Laurent, M.G.; Seron, D.; Sortais, P.; Villari, A.C.C. [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France); Angelique, J.C.; Orr, N.A. [Laboratoire de Physique Corpusculaire (CNRS/IN2P3), ISMRA, 14 - Caen (France); Blank, B. [CENBG, Centre d' Etudes Nucleaires de Bordeaux Gradignan, 33 (France); Clapier, F.; Ducourtieux, M.; Kandri-Rody, S.; Obert, J.; Pauwels, N.; Proust, J.; Putaux, J.C. [Institut de Physique Nucleaire, (IN2P3/CNRS) 91 - Orsay (France); Lepine, A. [IFUSP, C.P., Sao Paulo (Brazil)

    1999-07-01

    In order to define the future intensity and reliability of the on line radioactive beams for the SPIRAL project, an intense activity of research and development is being done around the target and the ion source problems. The main instrument for this purpose is the isotopic separator SIRa (Separateur d'Ions Radioactifs) installed in the D2 experimental cave at GANIL. One of the research axis is the production of multicharged radioactive condensable ions. In this aim, we have built a new compact ECR ion source, SHyPIE (Source Hybride pour la Production d'Ions Exotiques), whose original magnetic configuration is under patent since 1997. This new magnetic structure allows to place an internal production target very close to the plasma, while avoiding radiation damages of the sensitive permanent magnets. A series of on line experiments have been done, using SHyPIE with several internal target systems, and around thirty species of condensable and noble gases radioactive multicharged ion beams have been produced. The behaviour of the plasma in a close geometry with the production target has been studied. (authors)

  2. Electron motion analysis of a radial-radiated electron beam in a radial-line drift tube with finite magnetic field conducted

    Science.gov (United States)

    Dang, Fangchao; Zhang, Xiaoping; Zhong, Huihuang

    2017-02-01

    Radial-radiated electron beam is widely employed in radial-line structure microwave devices. The quality of the electron beam has a crucial effect on the operating performance of these devices. This paper analyzes theoretically this electron motion in a radial-line drift tube with finite magnetic field conducted. The beam width, spatial period, and fluctuation amplitude are quantitatively analyzed with different beam current parameters. By the particle-in-cell simulation, we examine the theoretical analysis under the condition of a designed realistic coil configuration. It indicates that the derived beam envelope function is capable of predicting the radial-radiated beam trajectory approximately. Meanwhile, it is found that the off-axial z-direction magnetic field, in spite of its greatly slight amplitude, is also one necessary consideration for the propagation characteristic of the radial-radiated electron beam. Furthermore, the presented electron motion analysis may be instructive for the design of the electronic optical system of the radial-line structure microwave devices.

  3. A study of diagnostic x-ray lines in heliumlike neon using an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Wargelin, Bradford John [Univ. of California, Berkeley, CA (United States)

    1993-10-01

    Heliumlike ions play an extremely important role in X-ray astrophysics because of their emissivity and because the relative intensities of their emission lines can be used to infer physical characteristics of X-ray emitting plasmas, including temperature, electron density, and ionization balance. In order to properly apply these diagnostics, accurate atomic data are required, including cross sections for collisional excitation and ionization, radiative rates, and the wavelengths and strengths of satellite lines. Although theoretical atomic models have been created to estimate many of the rates and cross sections involved, very few experimental results are available for comparison with theoretical predictions. This thesis describes an experimental study of heliumlike neon using an electron beam ion trap, a device specifically designed to study X-ray emission from highly charged ions. Using a low-energy X-ray spectrometer designed and built for this experiment, electron impact excitation cross sections and dielectronic satellite strengths were measured for all significant n = 2→1 emission lines in He-like and Li-like Ne over a range of energy extending from well below the direct excitation threshold of the lines to over fourteen times the threshold energy. The cross section for innershell ionization of Li-like Ne, which excites the He-like forbidden line, was also measured. In addition, the radiative and collisional depopulation rates of the metastable ls2s 3S1, state, which form the basis of the He-like Ne density diagnostic, were determined. Experimental results were generally in agreement with theoretical predictions, although some significant differences were noted, particularly for the wavelengths and resonance strengths of dielectronic satellites.

  4. Kaon-condensed hypernuclei as highly dense self-bound objects

    CERN Document Server

    Muto, Takumi

    2008-01-01

    The structure of $K^-$-condensed hypernuclei, which may be produced in the laboratory in strangeness-conserving processes, is investigated using an effective chiral Lagrangian for the kaon-baryon interaction, combined with a nonrelativistic baryon-baryon interaction model. It is shown that a large number of negative strangeness is needed for the formation of highly dense and deeply bound state with kaon condensates and that part of the strangeness should be carried by hyperons mixed in the nucleus. The properties of kaon-condensed hypernuclei such as the ground state energy and particle composition are discussed. Such a self-bound object has a long lifetime and may decay only through weak interaction processes. Comparison with other possible nuclear states is also made, such as kaon-condensed nuclei without mixing of hyperons and noncondensed multistrange hypernuclei. Implications of kaon-condensed hypernuclei for experiments are mentioned.

  5. Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences

    Directory of Open Access Journals (Sweden)

    Häring Peter

    2006-05-01

    Full Text Available Abstract Background The purpose of the study was the clinical implementation of a kV cone beam CT (CBCT for setup correction in radiotherapy. Patients and methods For evaluation of the setup correction workflow, six tumor patients (lung cancer, sacral chordoma, head-and-neck and paraspinal tumor, and two prostate cancer patients were selected. All patients were treated with fractionated stereotactic radiotherapy, five of them with intensity modulated radiotherapy (IMRT. For patient fixation, a scotch cast body frame or a vacuum pillow, each in combination with a scotch cast head mask, were used. The imaging equipment, consisting of an x-ray tube and a flat panel imager (FPI, was attached to a Siemens linear accelerator according to the in-line approach, i.e. with the imaging beam mounted opposite to the treatment beam sharing the same isocenter. For dose delivery, the treatment beam has to traverse the FPI which is mounted in the accessory tray below the multi-leaf collimator. For each patient, a predefined number of imaging projections over a range of at least 200 degrees were acquired. The fast reconstruction of the 3D-CBCT dataset was done with an implementation of the Feldkamp-David-Kress (FDK algorithm. For the registration of the treatment planning CT with the acquired CBCT, an automatic mutual information matcher and manual matching was used. Results and discussion Bony landmarks were easily detected and the table shifts for correction of setup deviations could be automatically calculated in all cases. The image quality was sufficient for a visual comparison of the desired target point with the isocenter visible on the CBCT. Soft tissue contrast was problematic for the prostate of an obese patient, but good in the lung tumor case. The detected maximum setup deviation was 3 mm for patients fixated with the body frame, and 6 mm for patients positioned in the vacuum pillow. Using an action level of 2 mm translational error, a target point

  6. Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch.

    Science.gov (United States)

    Ye, Yangbo; Zhu, Jiehua; Wang, Ge

    2004-03-01

    The goal of this paper is to study Cone-beam CT scanning along a helix of variable pitch. First the rationale and applications in medical imaging of variable pitch CT reconstruction are explained. Then formulas for the minimum detection window are derived. The main part of the paper proves a necessary and sufficient condition for the existence and uniqueness of PI-lines inside this variable pitch helix. These results are necessary steps toward an exact reconstruction algorithm for helix scanning of variable pitch, generalizing Katsevich's formula on constant pitch exact reconstruction. It is shown through an example that, when the derivative of the pitch function is not convex, or when the pitch function passes a inflection point and begins to slow down, PI-lines may be not unique near the rim of the helix cylinder. The conclusion is that the restriction on the pitch function is weaker, if the object is placed well within the helix cylinder and far from its rim, in order to preserve the uniqueness of PI-lines. If the object is near the rim, the restriction condition on the allowable pitch functions becomes stronger.

  7. Flavour symmetry breaking in the kaon parton distribution amplitude

    Directory of Open Access Journals (Sweden)

    Chao Shi

    2014-11-01

    Full Text Available We compute the kaon's valence-quark (twist-two parton distribution amplitude (PDA by projecting its Poincaré-covariant Bethe–Salpeter wave-function onto the light-front. At a scale ζ=2 GeV, the PDA is a broad, concave and asymmetric function, whose peak is shifted 12–16% away from its position in QCD's conformal limit. These features are a clear expression of SU(3-flavour-symmetry breaking. They show that the heavier quark in the kaon carries more of the bound-state's momentum than the lighter quark and also that emergent phenomena in QCD modulate the magnitude of flavour-symmetry breaking: it is markedly smaller than one might expect based on the difference between light-quark current masses. Our results add to a body of evidence which indicates that at any energy scale accessible with existing or foreseeable facilities, a reliable guide to the interpretation of experiment requires the use of such nonperturbatively broadened PDAs in leading-order, leading-twist formulae for hard exclusive processes instead of the asymptotic PDA associated with QCD's conformal limit. We illustrate this via the ratio of kaon and pion electromagnetic form factors: using our nonperturbative PDAs in the appropriate formulae, FK/Fπ=1.23 at spacelike-Q2=17 GeV2, which compares satisfactorily with the value of 0.92(5 inferred in e+e− annihilation at s=17 GeV2.

  8. Charged kaon and proton production in B-hadron decays

    Science.gov (United States)

    Tegenfeldt, Fredrik Per

    The production of charged kaons and protons in B-hadron decays has been measured in e+e- annihilations at centre-of-mass energies corresponding to the Z0 mass. In total 1.6 million hadronic Z0 decays were analysed, corresponding to about 690000 B-hadron decays. They were collected using the DELPHI detector at the LEP collider at CERN during 1994 and 1995. Events containing B-hadron decays were identified using special characteristics of the B-hadron decay topology. In particular, the long lifetime of the B-hadron leads to decay vertices significantly displaced relative the interaction point. These so called secondary vertices were reconstructed using a powerful micro vertex detector. In order to discriminate B-hadron decay products from fragmentation tracks, a method was used where the impact parameter measured by the vertex detector was employed as a discriminating variable. The tracks were thus divided into two classes, one compatible with the interaction point and the other compatible with a secondary vertex. An unfolding method was used to extract the true B-hadron decay tracks from the two classes. Charged kaons and protons were identified using the Ring Imaging CHerenkov (RICH) detector and corrected for misidentification using an efficiency matrix. The analysis resulted in charged kaon and proton spectra from B-hadron decays, including previously unmeasured momentum regions. Integrating the spectra yielded the following multiplicities n(B- hadron-->K+/- X)=0.683+/-0.021(stat) +/-0.017(syst) n(B- hadron-->p/p X)=0.127+/-0.013(stat) +/-0.019(syst) where the proton multiplicity does not include Λ baryon decay products.

  9. Application of robot kinematics methods to the simulation and control of neutron beam line positioning systems

    Energy Technology Data Exchange (ETDEWEB)

    James, Jonathan A. [Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom)]. E-mail: j.a.j.james@open.ac.uk; Edwards, Lyndon [Open University, Materials Engineering, Walton Hall, Milton Keynes, Buckinghamshire MK7 6AA (United Kingdom)

    2007-02-11

    Neutron stress measurements require specimens of complex geometry to be speedily and accurately positioned and oriented with respect to the neutron beam. Recognition that a majority of the specimen positioning systems in use at strain scanning facilities are effectively serial robot manipulators, suggests that the methods of serial robot kinematic modelling may be applied to advantage. The adoption of robotics methods provides a simple and reliable framework for controlling positioning systems of arbitrary geometry and complexity. In addition the numerical solution of the inverse kinematic problem is facilitated, allowing specimens to be automatically positioned and orientated so that pre-determined strain components are measured. It is also shown that, given sufficient degrees of freedom, a secondary characteristic of the measurement position such as the measurement count time may be simultaneously optimised.

  10. Non-leptonic kaon decays at large $N_c$

    CERN Document Server

    Donini, A; Pena, C; Romero-López, F

    2016-01-01

    We study the scaling with the number of colours, $N_c$, of the weak amplitudes mediating kaon mixing and decay. We evaluate the amplitudes of the two relevant current-current operators on the lattice for $N_c=3-7$. We conclude that the subleading $1/N_c$ corrections in $\\hat{B}_K$ are small, but those in the $K \\rightarrow \\pi\\pi$ amplitudes are large and fully anti-correlated in the $I=0, 2$ isospin channels. We briefly comment on the implications for the $\\Delta I=1/2$ rule.

  11. Kaon to Two Pions decays from Lattice QCD: Delta I = 1/2 rule and CP violation

    Science.gov (United States)

    Liu, Qi

    We report a direct lattice calculation of the K to pipi decay matrix elements for both the DeltaI=1/2 and 3/2 amplitudes A0 and A2 on a 2+1 flavor, domain wall fermion, 163x32x16 lattice ensemble and a 243x64x16 lattice ensemble. This is a complete calculation in which all contractions for the required ten, four-quark operators are evaluated, including the disconnected graphs in which no quark line connects the initial kaon and final two-pion states. These lattice operators are non-perturbatively renormalized using the Rome-Southampton method and the quadratic divergences are studied and removed. This is an important but notoriously difficult calculation, requiring high statistics on a large volume. In this work we take a major step towards the computation of the physicalK→pipi amplitudes by performing a complete calculation at unphysical kinematics with pions of mass 422 MeV and 329 MeV at rest in the kaon rest frame. With this simplification we are able to resolve Re(A0) from zero for the first time, with a 25% statistical error on the 163 lattice and 15% on the 243 lattice. The complex amplitude A2 is calculated with small statistical errors. We obtain the DeltaI=1/2 rule with an enhancement factor of 9.1(21) and 12.0(17) on these two ensembles. From the detailed analysis of the results we gain a deeper understanding of the origin of the DeltaI=1/2 rule. We also calculate the complex amplitude A0, a calculation central to understanding and testing the standard model of CP violation in the kaon system. The final result for the measure of direct CP violation, epsilon', calculated at unphysical kinematics has an order of 100% statistical error, so this only serves as an order of magnitude check.

  12. Research and Design of a Sample Heater for Beam Line 6-2c Transmission X-ray Microscope

    Energy Technology Data Exchange (ETDEWEB)

    Policht, Veronica; /Loyola U., Chicago /SLAC

    2012-08-27

    There exists a need for environmental control of samples to be imaged by the Transmission X-Ray Microscope (TXM) at the SSRLs Beam Line 6-2c. In order to observe heat-driven chemical or morphological changes that normally occur in situ, microscopes require an additional component that effectively heats a given sample without heating any of the microscope elements. The confinement of the heat and other concerns about the heaters integrity limit which type of heater is appropriate for the TXM. The bulk of this research project entails researching different heating methods used previously in microscopes, but also in other industrial applications, with the goal of determining the best-fitting method, and finally in designing a preliminary sample heater.

  13. Pencil-Beam Single-point-fed Dirac Leaky-Wave Antenna on a Transmission-Line Grid

    CERN Document Server

    Dorrah, Ayman H

    2016-01-01

    Leaky-wave antennas (LWAs) are widely used as single-point-fed linear antenna arrays. The extension of LWAs to 2D implies that they can be used as single-point-fed 2D antenna arrays without requiring a complex feeding network. However, generating a pencil beam from 2D LWAs is not straightforward and due care has to be taken for the design of the LWA. On the other hand, transmission-line (TL) grids have demonstrated interesting behaviors, such as an effective negative refractive index and growing of evanescent waves. In this paper, a singlepoint-fed TL-grid 2D Dirac leaky-wave antenna (DLWA) design is proposed that generates a pencil beam at both broadside and slightly tilted angles. The TL-grid unit cell is analytically treated in light of its scattering and impedance matrices. The optimized TL-grid unit cell is shown to exhibit a closed bandgap in the dispersion relation which is also linearly varying with frequency (hence it is a DLWA). The proposed 2D DLWA design is fabricated and the experimental results ...

  14. Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

    Energy Technology Data Exchange (ETDEWEB)

    Pivi, M.T.F.; King, F.; Kirby, R.E.; Markiewicz, T; Raubenheimer, T.O.; Seeman, J.; Wang, L.; /SLAC

    2008-07-03

    Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R&D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II.

  15. Superresolution imaging system by color-coded tilted-beam illumination in digital in-line holographic microscopy

    Science.gov (United States)

    Granero, L.; Micó, V.; Ferreira, C.; Zalevsky, Z.; García, J.

    2016-04-01

    Digital in-line holographic microscopy (DIHM) relates with the capability to achieve microscopic imaging working without lensless in the regime of holography. In essence, DIHM proposes a simple layout where a point source of coherent light illuminates the sample and the diffracted wavefront is recorded by a digital sensor. However, DIHM lacks high numerical aperture (NA) due to both geometrical distortion and the mandatory compromise between the illumination pinhole diameter, the illumination wavelength, and the need to obtain a reasonable light efficiency. One way to improve the resolution in DIHM, is by allowing superresolution imaging by angular multiplexing using tilted beam illumination. This illumination allows the on-axis diffraction of different spatial frequency content of the sample's spectrum, different in comparison to the case when on-axis illumination is used. And after recover this additional spectral content, a synthetic numerical aperture (SNA) expanding up the cutoff frequency of the system in comparison with the on-axis illumination case can be assembled in a digital post-processing stage. In this contribution, we present a method to achieve one-dimensional (1-D) superresolved imaging in DIHM by a SINGLE SHOT illumination, using color-coded tilted beams. The method has been named as L-SESRIM (Lensless Single-Exposure Super-Resolved Interferometric Microscopy). Although the technique was previously presented showing very preliminary results [34], in this contribution we expand the experimental characterization (USAF resolution test target) as well as derive the theoretical frame for SNA generation using different illumination wavelengths.

  16. Kaon-kaon scattering at maximal isospin from $N_f=2+1+1$ twisted mass lattice QCD

    CERN Document Server

    Helmes, Christopher; Knippschild, Bastian; Kostrzewa, Bartosz; Liu, Liuming; Urbach, Carsten; Werner, Markus

    2016-01-01

    We present results for the interaction of two kaons at maximal isospin. The calculation is based on 2+1+1 flavour gauge configurations generated by the ETM Collaboration (ETMC) featuring pion masses ranging from about 230 MeV to 450 MeV at three values of the lattice spacing. The elastic scattering length $a_0^{I=1}$ is calculated at several values of the bare strange quark and light quark masses. We find $M_K a_0 =-0.397(11)(_{-8}^{+0})$ as the result of a chiral and continuum extrapolation to the physical point. This number is compared to other lattice results.

  17. Pulse compression below 40fs at 1μm: The first step towards a short-pulse, high-energy beam line at LULI

    Science.gov (United States)

    Chen, Xiaowei; Zou, Jiping; Martin, Luc; Simon, Francois; Lopez-Martens, Rodrigo; Audebert, Patrick

    2010-08-01

    We present the upgrading project ELFIE (Equipement Laser de Forte Intensité et Energie) based on the "100TW" mixed Nd:glass CPA laser system at 1μm at LULI, which includes an energy enhancement and the development of a short-pulse, high-energy, good temporal contrast beam line (50fs/5J). We report the first experimental step towards the short-pulse, high-energy beam line: spectral broadening above 60nm from 7nm and temporal pulse compression below 40fs from 300fs at 1μm through a Krypton-filled hollow fiber compressor.

  18. Search for a bound state of kaon and pion

    CERN Document Server

    Kishimoto, T; Hayakawa, T; Ajimura, S; Itabashi, T; Matsuoka, K; Minami, S; Mitoma, Y; Sakaguchi, A; Shimizu, Y; Terai, K; Sato, T; Noumi, H; Sekimoto, M; Takahashi, H; Fukuda, T; Imoto, W; Mizoi, Y

    2012-01-01

    We have searched for a bound state of kaon and pion denoted by $X$. The $X$ was conjectured to explain the so-called $\\Theta^+$ resonance as a bound state of kaon, pion and nucleon. This model explains almost all properties of the $\\Theta^+$, however, the model works only if the $K \\pi$ interaction is strongly attractive. It is so strong that it could make a bound state $X$. Here we report a result of the search for the $X$ by using the $K^+ + N \\rightarrow X^+ + N$ reaction at P$_K\\sim$ 1.2 GeV/c. The $X^+ \\rightarrow K^+ \\gamma \\gamma$ decay produces $K^+$ in momentum region where other processes cannot fill. We observed signature of the $X^+$ with statistical significance of 2 $\\sigma$. Production cross section of $X$ with respect to that of $\\pi^0$ is 1$\\pm$0.5% if we take it as an evidence and 1.5% if we set an upper limit.

  19. Probing CPT in transitions with entangled neutral kaons

    CERN Document Server

    Bernabeu, J; Villanueva-Perez, P

    2015-01-01

    In this paper we present a novel CPT symmetry test in the neutral kaon system based, for the first time, on the direct comparison of the probabilities of a transition and its CPT reverse. The required interchange of "in" $\\leftrightarrow$ "out" states for a given process is obtained exploiting the Einstein-Podolsky-Rosen correlations of neutral kaon pairs produced at a $\\phi$-factory. The observable quantities have been constructed by selecting the two semileptonic decays for flavour tag, the $\\pi\\pi$ and $3\\pi^0$ decays for CP tag and the time orderings of the decay pairs. The interpretation in terms of the standard Weisskopf-Wigner approach to this system, directly connects CPT violation in these observables to the violating $\\Re\\delta$ parameter in the mass matrix of $K^0$-$\\bar{K^0}$, a genuine CPT violating effect independent of $\\Delta \\Gamma$ and not requiring the decay as an essential ingredient. Possible spurious effects induced by CP violation in the decay and/or a violation of the $\\Delta S= \\Delta...

  20. High-Power Ion Beam Characteristics of a Magnetic Multi-Pole Line-Cusp Ion Source for the HL-2A Tokomak

    Institute of Scientific and Technical Information of China (English)

    ZOU Gui-Qing; LEI Guang-Jiu; JIANG Shao-Feng; CAO Jian-Yong; YU Li-Ming; LU Da-Lun; YANG Li-Mei; LIU He; JIANG Tao; ZHANG Xian-Ming

    2009-01-01

    A circular magnetic multi-pole line-cusp ion source with a nominal 45 keV 25 A hydrogen ion beam is developed for the neutral beam injector of the HL-2A tokomak.At present,this bucket ion source can produce a 40 keV 20 A hydrogen ion beam for less than 100 ms on a test bed,and a 35 ke V 13A ion beam for 300 ms on the injector of the HL-2A tokomak.The 1/e hag-width of the ion beam power profile is about 6.0±0.2 cm at the position of 3.26 m downstream from ion source,and the corresponding divergence degree is nearly 1.1.The optimum perveance matched conditions were obtained experimentally,and were in good agreement with the values from experiential equation of Uhlemann et al.The maximum of optimum perveance reached 2.2×10-6 A/V1.5 for 38 keV beam energy.An ion beam with above 60% H+ species fraction can be achieved,which was measured by Hα light Doppler shift spectroscopy.According to research results,a neutral beam with a total power of more than 0.6 MW was successfully injected into the plasma of the HL-2A Tokomak in 2008.

  1. NA48/2. Precision Measurement of Charged Kaon Decay parameters with an Extended NA48 Setup

    CERN Multimedia

    De beer, M; Derre, J; Celeghini, E; Bazylev, S; Falaleev, V; Peyaud, B; Bendel, M; Kekelidze, V; Potrebenikov, Y; Ceccucci, A; Behler, M; Madigozhin, D

    2002-01-01

    A high statistics study of charged kaon decays is proposed using a novel design for simultaneous $K^+/K^-$ beams, and NA48 setup upgraded with a transition radiation detector. The main goal is to measure CP-violating asymmetry in $K^{\\pm}\\rightarrow \\pi^+ \\pi^- \\pi^{\\pm}$ decays with an accuracy of $2.2 \\times 10^{-4}$. In addition CP-violating asymmetry will be measured in $K^{\\pm}\\rightarrow \\pi^0 \\pi^0 \\pi^{\\pm}$ decays, more than $10^6$ of $K_{e4}$ decays will be accumulated which allow to measure a scattering length parameter $a^0_0$ with an accuracy better than 0.01, and some other rare decays will be studied as well.

  2. Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines

    Science.gov (United States)

    Dennerlein, Frank; Katsevich, Alexander; Lauritsch, Guenter; Hornegger, Joachim

    2005-04-01

    X-ray 3D rotational angiography based on C-arm systems has become a versatile and established tomographic imaging modality for high contrast objects in interventional environment. Improvements in data acquisition, e.g. by use of flat panel detectors, will enable C-arm systems to resolve even low-contrast details. However, further progress will be limited by the incompleteness of data acquisition on the conventional short-scan circular source trajectories. Cone artifacts, which result from that incompleteness, significantly degrade image quality by severe smearing and shading. To assure data completeness a combination of a partial circle with one or several line segments is investigated. A new and efficient reconstruction algorithm is deduced from a general inversion formula based on 3D Radon theory. The method is theoretically exact, possesses shift-invariant filtered backprojection (FBP) structure, and solves the long object problem. The algorithm is flexible in dealing with various circle and line configurations. The reconstruction method requires nothing more than the theoretically minimum length of scan trajectory. It consists of a conventional short-scan circle and a line segment approximately twice as long as the height of the region-of-interest. Geometrical deviations from the ideal source trajectory are considered in the implementation in order to handle data of real C-arm systems. Reconstruction results show excellent image quality free of cone artifacts. The proposed scan trajectory and reconstruction algorithm assure excellent image quality and allow low-contrast tomographic imaging with C-arm based cone-beam systems. The method can be implemented without any hardware modifications on systems commercially available today.

  3. Regge-plus-resonance predictions for kaon photoproduction from the neutron

    CERN Document Server

    Vancraeyveld, P; Ryckebusch, J; Van Cauteren, T

    2009-01-01

    We present predictions for n(gamma,K+)Sigma- differential cross sections and photon-beam asymmetries and compare them to recent LEPS data. We adapt a Regge-plus-resonance (RPR) model developed to describe photoinduced and electroinduced kaon production off protons. The non-resonant contributions to the amplitude are modelled in terms of K+(494) and K*+(892) Regge-trajectory exchange. This amplitude is supplemented with a selection of s-channel resonance diagrams. The three Regge-model parameters of the n(gamma,K+)Sigma- amplitude are derived from the ones fitted to proton data through SU(2) isospin considerations. A fair description of the n(gamma,K+)Sigma- data is realized, which demonstrates the Regge model's robustness and predictive power. Conversion of the resonances' couplings from the proton to the neutron is more challenging, as it requires knowledge of the photocoupling helicity amplitudes. We illustrate how the uncertainties of the helicity amplitudes proliferate and heavily restrain the predictive ...

  4. Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised protons

    Directory of Open Access Journals (Sweden)

    C. Adolph

    2015-05-01

    Full Text Available Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.

  5. Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised proton

    CERN Document Server

    Adolph, C; Alexeev, M G; Alexeev, G D; Amoroso, A; Andrieux, V; Anosov, V; Austregesilo, A; Badełek, B; Balestra, F; Barth, J; Baum, G; Beck, R; Bedfer, Y; Berlin, A; Bernhard, J; Bicker, K; Bieling, J; Birsa, R; Bisplinghoff, J; Bodlak, M; Boer, M; Bordalo, P; Bradamante, F; Braun, C; Bressan, A; Büchele, M; Burtin, E; Capozza, L; Chiosso, M; Chung, S U; Cicuttin, A; Crespo, M L; Curiel, Q; Dalla Torre, S; Dasgupta, S S; Dasgupta, S; Denisov, O Yu; Donskov, S V; Doshita, N; Duic, V; Dünnweber, W; Dziewiecki, M; Efremov, A; Elia, C; Eversheim, P D; Eyrich, W; Faessler, M; Ferrero, A; Filin, A; Finger, M; Finger jr , M; Fischer, H; Franco, C; du Fresne von Hohenesche, N; Friedrich, J M; Frolov, V; Gautheron, F; Gavrichtchouk, O P; Gerassimov, S; Geyer, R; Gnesi, I; Gobbo, B; Goertz, S; Gorzellik, M; Grabmüller, S; Grasso, A; Grube, B; Grussenmeyer, T; Guskov, A; Guthörl, T; Haas, F; von Harrach, D; Hahne, D; Hashimoto, R; Heinsius, F H; Herrmann, F; Hinterberger, F; Höppner, Ch; Horikawa, N; d’Hose, N; Huber, S; Ishimoto, S; Ivanov, A; Ivanshin, Yu; Iwata, T; Jahn, R; Jary, V; Jasinski, P; Jörg, P; Joosten, R; Kabuß, E; Ketzer, B; Khaustov, G V; Khokhlov, Yu A; Kisselev, Yu; Klein, F; Klimaszewski, K; Koivuniemi, J H; Kolosov, V N; Kondo, K; Königsmann, K; Konorov, I; Konstantinov, V F; Kotzinian, A M; Kouznetsov, O; Krämer, M; Kroumchtein, Z V; Kuchinski, N; Kunne, F; Kurek, K; Kurjata, R P; Lednev, A A; Lehmann, A; Levillain, M; Levorato, S; Lichtenstadt, J; Maggiora, A; Magnon, A; Makke, N; Mallot, G K; Marchand, C; Martin, A; Marzec, J; Matousek, J; Matsuda, H; Matsuda, T; Meshcheryakov, G; Meyer, W; Michigami, T; Mikhailov, Yu V; Miyachi, Y; Nagaytsev, A; Nagel, T; Nerling, F; Neubert, S; Neyret, D; Nikolaenko, V I; Novy, J; Nowak, W -D; Nunes, A S; Olshevsky, A G; Orlov, I; Ostrick, M; Panknin, R; Panzieri, D; Parsamyan, B; Paul, S; Peshekhonov, D V; Platchkov, S; Pochodzalla, J; Polyakov, V A; Pretz, J; Quaresma, M; Quintans, C; Ramos, S; Regali, C; Reicherz, G; Rocco, E; Rossiyskaya, N S; Ryabchikov, D I; Rychter, A; Samoylenko, V D; Sandacz, A; Sarkar, S; Savin, I A; Sbrizzai, G; Schiavon, P; Schill, C; Schlüter, T; Schmidt, K; Schmieden, H; Schönning, K; Schopferer, S; Schott, M; Shevchenko, O Yu; Silva, L; Sinha, L; Sirtl, S; Slunecka, M; Sosio, S; Sozzi, F; Srnka, A; Steiger, L; Stolarski, M; Sulc, M; Sulej, R; Suzuki, H; Szabelski, A; Szameitat, T; Sznajder, P; Takekawa, S; ter Wolbeek, J; Tessaro, S; Tessarotto, F; Thibaud, F; Uhl, S; Uman, I; Virius, M; Wang, L; Weisrock, T; Wilfert, M; Windmolders, R; Wollny, H; Zaremba, K; Zavertyaev, M; Zemlyanichkina, E; Ziembicki, M; Zink, A

    2015-01-01

    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.

  6. Inclusive neutral kaon production in 70 GeV/c K/sup +/p interactions

    CERN Document Server

    Barth, Monique; Beaufays, J; Berejnov, V V; Caso, C; Chliapnikov, P V; Contri, R; De Clercq, C; De Wolf, E A; Drevermann, H; Dumont, J J; Dziembowski, Z; Fenyuk, A; Fontanelli, F; Gatignon, L; Gerdyukov, L N; Goldschmidt-Clermont, Yves; Grard, F; Gritsaenko, I; Gumenyuk, S A; Hanton, J; Harigel, G G; Johnson, D P; Kittel, E W; Kubic, V; Lemonne, J; Lugovsky, S B; Metzger, W J; Milstene, C; Monge, R; Nikitin, S; Nikolaenko, V; Peeters, P; Petrovikh, Y; Porte, J P; Ronjin, V; Ross, R T; Schotanus, D J; Squarcia, S; Stergiou, Athanase; Theocharopoulos, P; Trevisan, U; Utochkin, B; Van de Walle, R T; Van der Poel, P A; Vassiliadis, G; Yarba, V A

    1981-01-01

    The inclusive production of neutral kaons in 70 GeV/c K/sup +/p interactions is studied with the CERN BEBC bubble chamber. The (semi-) inclusive cross sections are interpreted in terms of the various strangeness channels leading to neutral kaon production. The invariant inclusive cross section for kaon production is studied as a function of p/sub t//sup 2/ and the Feynman variable x. The latter distributions are considered both 'raw' and corrected for the presence of K/sup 0/'s resulting from K* decay. They are compared with the prediction expected from the Regge-Mueller formalism, the recombination model and fragmentation models. (24 refs).

  7. Rare isotope beams at ISAC—target & ion source systems

    Science.gov (United States)

    Bricault, Pierre G.; Ames, Friedhelm; Dombsky, Marik; Kunz, Peter; Lassen, Jens

    2014-01-01

    The present status of the ISAC facility for rare isotopes beams after its first 10 years of operation is presented. Planning for the ISAC facility started in 1985 with the Parksville workshop on radioactive ion beams (Buchmann and D'Auria 1985). It was put on halt by the KAON proposal and planning was only resumed in 1993 after the cancellation of KAON. The ISAC facility was built to satisfy the scientific need for accelerated beams of rare isotopes for use in applications such as nuclear physics, nuclear astrophysics, atomic and condensed matter physics as well as medicine. At the time of the ISAC proposal submission, a number of facilities were either planned or under construction. In order to have an impact in the field, the requirements and specifications for the driver beam intensity on target was set to 100 μA, 500 MeV protons, which for ISAC results in a driver beam power of 50 kW.

  8. SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Held, M; Morin, O; Pouliot, J [UC San Francisco, San Francisco, CA (United States)

    2014-06-01

    Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgent and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.

  9. One-prong τ decays with neutral kaons

    Science.gov (United States)

    Acciarri, M.; Adam, A.; Adriani, O.; Aguilar-Benitez, M.; Ahlen, S.; Alpat, B.; Alcaraz, J.; Allaby, J.; Aloisio, A.; Alverson, G.; Alviggi, M. G.; Ambrosi, G.; An, Q.; Anderhub, H.; Andreev, V. P.; Angelescu, T.; Antreasyan, D.; Arefiev, A.; Azemoon, T.; Aziz, T.; Baba, P. V. K. S.; Bagnaia, P.; Baksay, L.; Ball, R. C.; Banerjee, S.; Banicz, K.; Barillère, R.; Barone, L.; Bartalini, P.; Baschirotto, A.; Basile, M.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bencze, Gy. L.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B. L.; Biasini, M.; Biland, A.; Bilei, G. M.; Bizzarri, R.; Blaising, J. J.; Bobbink, G. J.; Bock, R.; Böhm, A.; Borgia, B.; Boucham, A.; Bourilkov, D.; Bourquin, M.; Boutigny, D.; Bouwens, B.; Brambilla, E.; Branson, J. G.; Brigljevic, V.; Brock, I. C.; Bujak, A.; Burger, J. D.; Burger, W. J.; Burgos, C.; Busenitz, J.; Buytenhuijs, A.; Cai, X. D.; Capell, M.; Romeo, G. Cara; Caria, M.; Carlino, G.; Cartacci, A. M.; Casaus, J.; Castellini, G.; Castello, R.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chan, A.; Chang, Y. H.; Chaturvedi, U. K.; Chemarin, M.; Chen, A.; Chen, C.; Chen, G.; Chen, G. M.; Chen, H. F.; Chen, H. S.; Chen, M.; Chiefari, G.; Chien, C. Y.; Choi, M. T.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coan, T. E.; Cohn, H. O.; Coignet, G.; Colino, N.; Commichau, V.; Costantini, S.; Cotorobai, F.; de La Cruz, B.; Cui, X. T.; Cui, X. Y.; Dai, T. S.; D'Alessandro, R.; de Asmundis, R.; de Boeck, H.; Degré, A.; Deiters, K.; Dénes, E.; Denes, P.; Denotaristefani, F.; Dibitonto, D.; Diemoz, M.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dorne, I.; Dova, M. T.; Drago, E.; Duchesneau, D.; Duinker, P.; Duran, I.; Dutta, S.; Easo, S.; Efremenko, Yu.; El Mamouni, H.; Engler, A.; Eppling, F. J.; Erné, F. C.; Ernenwein, J. P.; Extermann, P.; Fabbretti, R.; Fabre, M.; Faccini, R.; Falciano, S.; Favara, A.; Fay, J.; Felcini, M.; Ferguson, T.; Fernandez, D.; Fernandez, G.; Ferroni, F.; Fesefeldt, H.; Fiandrini, E.; Field, J. H.; Filthaut, F.; Fisher, P. H.; Forconi, G.; Fredj, L.; Freudenreich, K.; Gailloud, M.; Galaktionov, Yu.; Ganguli, S. N.; Garcia-Abia, P.; Gau, S. S.; Gentile, S.; Gerald, J.; Gheordanescu, N.; Giagu, S.; Goldfarb, S.; Goldstein, J.; Gong, Z. F.; Gonzalez, E.; Gougas, A.; Goujon, D.; Gratta, G.; Gruenewald, M. W.; Gu, C.; Guanziroli, M.; Gupta, V. K.; Gurtu, A.; Gustafson, H. R.; Gutay, L. J.; Hartmann, B.; Hasan, A.; He, J. T.; Hebbeker, T.; Hervé, A.; Hilgers, K.; van Hoek, W. C.; Hofer, H.; Hoorani, H.; Hou, S. R.; Hu, G.; Ilyas, M. M.; Innocente, V.; Janssen, H.; Jin, B. N.; Jones, L. W.; de Jong, P.; Josa-Mutuberria, I.; Kasser, A.; Khan, R. A.; Kamyshkov, Yu.; Kapinos, P.; Kapustinsky, J. S.; Karyotakis, Y.; Kaur, M.; Khokhar, S.; Kienzle-Focacci, M. N.; Kim, D.; Kim, J. K.; Kim, S. C.; Kim, Y. G.; Kinnison, W. W.; Kirkby, A.; Kirkby, D.; Kirkby, J.; Kirsch, S.; Kittel, W.; Klimentov, A.; König, A. C.; Koffeman, E.; Kornadt, O.; Koutsenko, V.; Koulbardis, A.; Kraemer, R. W.; Kramer, T.; Krenz, W.; Kuijten, H.; Kunin, A.; de Guevara, P. Ladron; Landi, G.; Lapoint, C.; Lassila-Perini, K.; Laurikainen, P.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, J.; Lecoq, P.; Le Coultre, P.; Lee, J. S.; Lee, K. Y.; Leggett, C.; Le Goff, J. M.; Leiste, R.; Lenti, M.; Leonardi, E.; Levtchenko, P.; Li, C.; Lieb, E.; Lin, W. T.; Linde, F. L.; Lindemann, B.; Lista, L.; Liu, Y.; Liu, Z. A.; Lohmann, W.; Longo, E.; Lu, W.; Lu, Y. S.; Lübelsmeyer, K.; Luci, C.; Luckey, D.; Ludovici, L.; Luminari, L.; Lustermann, W.; Ma, W. G.; Macchiolo, A.; Maity, M.; Malgeri, L.; Malik, R.; Malinin, A.; Maña, C.; Mangla, S.; Maolinbay, M.; Marchesini, P.; Marin, A.; Martin, J. P.; Marzano, F.; Massaro, G. G. G.; Mazumdar, K.; McNally, D.; Mele, S.; Merk, M.; Merola, L.; Meschini, M.; Metzger, W. J.; Mi, Y.; Mihul, A.; van Mil, A. J. W.; Mir, Y.; Mirabelli, G.; Mnich, J.; Möller, M.; Monaco, V.; Monteleoni, B.; Moore, R.; Morand, R.; Morganti, S.; Moulai, N. E.; Mount, R.; Müller, S.; Nagy, E.; Nahn, S.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niaz, M. A.; Nippe, A.; Nowak, H.; Organtini, G.; Ostonen, R.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Pascale, G.; Passaleva, G.; Patricelli, S.; Paul, T.; Pauluzzi, M.; Paus, C.; Pauss, F.; Pei, Y. J.; Pensotti, S.; Perret-Gallix, D.; Pevsner, A.; Piccolo, D.; Pieri, M.; Pinto, J. C.; Piroué, P. A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Produit, N.; Qureshi, K. N.; Raghavan, R.; Rahal-Callot, G.; Rancoita, P. G.; Rattaggi, M.; Raven, G.; Razis, P.; Read, K.; Redaelli, M.; Ren, D.; Ren, Z.; Rescigno, M.; Reucroft, S.; Ricker, A.; Riemann, S.; Riemers, B. C.; Riles, K.; Rind, O.; Rizvi, H. A.; Ro, S.; Robohm, A.; Rodin, J.; Rodriguez, F. J.; Roe, B. P.; Röhner, M.; Röhner, S.; Romero, L.; Rosier-Lees, S.; Rosselet, Ph.; van Rossum, W.; Roth, S.; Rubio, J. A.; Rykaczewski, H.; Salicio, J.; Salicio, J. M.; Sanchez, E.; Santocchia, A.; Sarakinos, M. E.; Sarkar, S.; Sartorelli, G.; Sassowsky, M.; Sauvage, G.; Schäfer, C.; Schegelsky, V.; Schmitz, D.; Schmitz, P.; Schneegans, M.; Schoeneich, B.; Scholz, N.; Schopper, H.; Schotanus, D. J.; Schulte, R.; Schultze, K.; Schwenke, J.; Schwering, G.; Sciacca, C.; Sehgal, R.; Seiler, P. G.; Sens, J. C.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shukla, J.; Shumilov, E.; Son, D.; Sopczak, A.; Soulimov, V.; Smith, B.; Spickermann, T.; Spillantini, P.; Steuer, M.; Stickland, D. P.; Sticozzi, F.; Stone, H.; Stoyanov, B.; Strauch, K.; Sudhakar, K.; Sultanov, G.; Sun, L. Z.; Susinno, G. F.; Suter, H.; Swain, J. D.; Syed, A. A.; Tang, X. W.; Taylor, L.; Timellini, R.; Ting, Samuel C. C.; Ting, S. M.; Toker, O.; Tonutti, M.; Tonwar, S. C.; Tóth, J.; Tsaregorodtsev, A.; Tsipolitis, G.; Tully, C.; Tuchscherer, H.; Ulbricht, J.; Urbán, L.; Uwer, U.; Valente, E.; van de Walle, R. T.; Vetlitsky, I.; Viertel, G.; Vikas, P.; Vikas, U.; Vivargent, M.; Voelkert, R.; Vogel, H.; Vogt, H.; Vorobiev, I.; Vorobyov, A. A.; Vorobyov, An. A.; Vuilleumier, L.; Wadhwa, M.; Wallraff, W.; Wang, J. C.; Wang, X. L.; Wang, Y. F.; Wang, Z. M.; Weber, A.; Weill, R.; Willmott, C.; Wittgenstein, F.; Wu, S. X.; Wynhoff, S.; Xu, J.; Xu, Z. Z.; Yang, B. Z.; Yang, C. G.; Yang, G.; Yao, X. Y.; Ye, C. H.; Ye, J. B.; Ye, Q.; Yeh, S. C.; You, J. M.; Yunus, N.; Yzerman, M.; Zaccardelli, C.; Zalite, An.; Zemp, P.; Zeng, J. Y.; Zeng, M.; Zeng, Y.; Zhang, Z.; Zhang, Z. P.; Zhou, B.; Zhou, G. J.; Zhou, J. F.; Zhou, Y.; Zhu, G. Y.; Zhu, R. Y.; Zichichi, A.; van der Zwaan, B. C. C.

    1995-02-01

    We have analyzed one-prong τ decays with neutral kaons using the information from a fine-grained hadron calorimeter. The data sample consists of 43 500 Z → τ+τ-( γ) events collected by the L3 detector at LEP in 1991, 1992 and 1993. The following branching fractions are measured: B(τ - → ν τπ -overlineK0) = 0.0095 ± 0.0015 (stat) ± 0.0006(syst); B(τ - → ν τπ - π 0overlineK0) = 0.0041 ± 0.0012(stat) ± 0.0003(syst) and B(τ - → ν τπ -K 0overlineK0) = 0.0031 ± 0.0012(stat) ± 0.0004(syst) .

  10. Ratio of Pion Kaon Production in Proton Carbon Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Andrey V. [Harvard Univ., Cambridge, MA (United States)

    2007-05-01

    The ratio of pion-kaon production by 120 GeV/c protons incident on carbon target is presented. The data was recorded with the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory. Production ratios of K++, K--, K-/K+, and π-+ are measured in 24 bins in longitudinal momentum from 20 to 90 GeV/c and transverse momentum up to 2 GeV/c. The measurement is compared to existing data sets, particle production Monte Carlo results from FLUKA-06, parametrization of proton-beryllium data at 400/450 GeV/c, and ratios measured by the MINOS experiment on the NuMI target.

  11. Kaon semileptonic decay form factors with HISQ valence quarks

    CERN Document Server

    Gamiz, E; Bazavov, A; Bernard, C; Bouchard, C; DeTar, C; Du, D; El-Khadra, A X; Foley, J; Freeland, E D; Gottlieb, Steven; Heller, U M; Kim, J; Kronfeld, A S; Laiho, J; Levkova, L; Mackenzie, P B; Neil, E T; Oktay, M B; Qiu, Si-Wei; Simone, J N; Sugar, R; Toussaint, D; Van de Water, R S; Zhou, R

    2012-01-01

    We report on the status of our kaon semileptonic form factor calculations using the highly-improved staggered quark (HISQ) formulation to simulate the valence fermions. We present results for the form factor f_+^{K \\pi}(0) on the asqtad N_f=2+1 MILC configurations, discuss the chiral-continuum extrapolation, and give a preliminary estimate of the total error. We also present a more preliminary set of results for the same form factor but with the sea quarks also simulated with the HISQ action; these results include data at the physical light quark masses. The improvements that we expect to achieve with the use of the HISQ configurations and simulations at the physical quark masses are briefly discussed.

  12. Higher Moments of Net-Kaon Multiplicity Distributions at STAR

    CERN Document Server

    ,

    2016-01-01

    Fluctuations of conserved quantities such as baryon number (B), electric charge number (Q), and strangeness number (S), are sensitive to the correlation length and can be used to probe non-gaussian fluctuations near the critical point. Experimentally, higher moments of the multiplicity distributions have been used to search for the QCD critical point in heavy-ion collisions. In this paper, we report the efficiency-corrected cumulants and their ratios of mid- rapidity (|y| < 0.5) net-kaon multiplicity distributions in Au+Au collisions at 7.7, 11.5, 14.5, 19.6, 27, 39, 62.4, and 200 GeV collected in 2010, 2011, and 2014 with STAR at RHIC. The centrality and energy dependence of the cumulants and their ratios, are presented. Furthermore, the comparisons with baseline calculations (Poisson) and non-critical-point models (UrQMD) are also discussed.

  13. Kaon-nucleon couplings for weak decays of hypernuclei

    CERN Document Server

    Savage, M J

    1995-01-01

    We investigate the weak kaon-nucleon (NNK) S-wave and P-wave interactions using heavy baryon chiral perturbation theory. The leading 1-loop SU(3) breaking contributions to the ppK, pnK, and nnK couplings are computed. We find that they suppress all NNK amplitudes by 30\\% to 50\\%. The ratio of neutron-induced to proton-induced hypernuclear decay widths is sensitive to such reductions. It has been argued that the discrepancy between the predicted and observed P-wave amplitudes in \\Delta s=1 hyperon decay results from an accidental cancellation between tree-level amplitudes, and is not a fundamental problem for chiral perturbation theory. Agreement between experimentally determined NNK P-wave amplitudes and our estimates would support this explanation.

  14. Calculation of BSM Kaon B-parameters using Staggered Quarks

    CERN Document Server

    Jang, Yong-Chull; Kim, Jangho; Kim, Seonghee; Lee, Weonjong; Leem, Jaehoon; Pak, Jeonghwan; Park, Sungwoo; Jung, Chulwoo; Kim, Hyung-Jin; Sharpe, Stephen R; Yoon, Boram

    2014-01-01

    We present updated results for kaon B-parameters for operators arising in models of new physics. We use HYP-smeared staggered quarks on the $N_f = 2+1$ MILC asqtad lattices. During the last year we have added new ensembles, which has necessitated chiral-continuum fitting with more elaborate fitting functions. We have also corrected an error in a two-loop anomalous dimension used to evolve results between different scales. Our results for the beyond-the-Standard-Model B-parameters have total errors of $5-10$\\%. We find that the discrepancy observed last year between our results and those of the RBC/UKQCD and ETM collaborations for some of the B-parameters has been reduced from $4\\!-\\!5\\,\\sigma$ to $2\\!-\\!3\\,\\sigma$.

  15. MULTI-bar K (hyper)nuclei and Kaon Condensation

    Science.gov (United States)

    Gazda, D.; Mareš, J.; Friedman, E.; Gal, A.

    2010-10-01

    We report on recent relativistic mean-field calculations of multi-bar K nuclei1,2 which were performed fully and self-consistently across the periodic table. The bar K separation energy B{bar K} as well as the nuclear and bar K-meson densities were found to saturate with the number of antikaons in the nuclear medium. Saturation appears robust against a wide range of variations, including the nuclear model used and the type of boson fields mediating the strong interactions. In addition, we have explored properties of kaonic hypernuclei - strange systems made of nucleons, hyperons and K- mesons. We observed saturation also in these objects. Since the bar K separation energy B{bar K} does not exceed 200 MeV, multi-bar K nuclei lie energetically well above multi-hyperonic nuclei and it is unlikely that kaon condensation could occur in strong-interaction self-bound hadronic matter.

  16. Analysis of the pion-kaon sigma-term and related topics

    CERN Document Server

    Frink, M; Meißner, Ulf G; Frink, Matthias; Kubis, Bastian; Mei{\\ss}ner, Ulf-G.

    2002-01-01

    We calculate the one-loop contributions to the difference \\Delta_{\\pi K} between the isoscalar on-shell pion-kaon scattering amplitude at the Cheng-Dashen point and the scalar form factor \\Gamma_K (2M_\\pi^2) in the framework of three flavor chiral perturbation theory. These corrections turn out to be small. This is further sharpened by treating the kaons as heavy fields (two flavor chiral perturbation theory). We also analyze the two-loop corrections to the kaon scalar form factor based on a dispersive technique. We find that these corrections are smaller than in the comparable case of the scalar form factor of the pion. This is related to the weaker final state interactions in the pion-kaon channel.

  17. Influence of Chiral Mean Field on Kaon In-plane Flow in Heavy Ion Collisions

    Institute of Scientific and Technical Information of China (English)

    ZHENG Yu-Ming; FUCHS Christian; FAESSLER Amand; SHEKHTER Kirril; SRISAWAD Pornrad; KOBDAJ Chinorat; YAN Yu-Peng

    2004-01-01

    The influence of the chiral mean field on the K+ in-plane flow in heavy ion collisions at SIS energy is investigated within covariant kaon dynamics. For the kaon mesons inside the nuclear medium a quasi-particle picture including scalar and vector fields is adopted and compared to the standard treatment with a static potential. It is confirmed that a Lorentz force from spatial component of the vector field provides an important contribution to the inmedium kaon dynamics and strongly counterbalances the influence of the vector potential on the K+ in-plane flow. The calculated results show that the new FOPI data can be reasonably described using the Brown & Rho parametrization,which partly takes into account the correction of higher order contributions in the chiral expansion. This indicates that one can abstract the information on the kaon potential in a nuclear medium from the analysis of the K+ in-plane flow.

  18. Bose-Einstein correlations of charged and neutral kaons in deep inelastic scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S.; Derrick, M.; Magill, S. [Argonne National Laboratory, Argonne, IL (US)] (and others)

    2007-05-15

    Bose-Einstein correlations of charged and neutral kaons have been measured in e{sup {+-}}p deep inelastic scattering with an integrated luminosity of 121 pb{sup -1} using the ZEUS detector at HERA. The two-particle correlation function was studied as a function of the four-momentum difference of the kaon pairs, Q{sub 12}={radical}(-(p{sub 1}-p{sub 2}){sup 2}), assuming a Gaussian shape for the particle source. The values of the radius of the production volume, r, and of the correlation strength, {lambda}, were obtained for both neutral and charged kaons. The radii for charged and neutral kaons are similar and are consistent with those obtained at LEP. (orig.)

  19. The simultaneous and nearly-collinear K0 beams for experiment NA48

    CERN Document Server

    Biino, C; Gatignon, L; Grafström, P; Wahl, H

    1998-01-01

    A system of simultaneous and nearly-collinear beams of long- and short-lived neutral kaons has been installed and extensively studied. These beams form an integral part of the NA48 experiment at the C ERN SPS, which aims to study direct CP-violation. The beam splitting is achieved by a novel application of a bent silicon crystal. The principles and design of these beams, as well as their performanc e are described.

  20. Parametic Study of the current limit within a single driver-scaletransport beam line of an induction Linac for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Prost, Lionel Robert [Univ. of California, Berkeley, CA (United States)

    2004-01-01

    The High Current Experiment (HCX) at Lawrence Berkeley National Laboratory is part of the US program that explores heavy-ion beam as the driver option for fusion energy production in an Inertial Fusion Energy (IFE) plant. The HCX is a beam transport experiment at a scale representative of the low-energy end of an induction linear accelerator driver. The primary mission of this experiment is to investigate aperture fill factors acceptable for the transport of space-charge-dominated heavy-ion beams at high intensity (line charge density ~0.2 μC/m) over long pulse durations (4 μs) in alternating gradient focusing lattices of electrostatic or magnetic quadrupoles. This experiment is testing transport issues resulting from nonlinear space-charge effects and collective modes, beam centroid alignment and steering, envelope matching, image charges and focusing field nonlinearities, halo and, electron and gas cloud effects. We present the results for a coasting 1 MeV K+ ion beam transported through ten electrostatic quadrupoles. The measurements cover two different fill factor studies (60% and 80% of the clear aperture radius) for which the transverse phase-space of the beam was characterized in detail, along with beam energy measurements and the first halo measurements. Electrostatic quadrupole transport at high beam fill factor (~80%) is achieved with acceptable emittance growth and beam loss. We achieved good envelope control, and re-matching may only be needed every ten lattice periods (at 80% fill factor) in a longer lattice of similar design. We also show that understanding and controlling the time dependence of the envelope parameters is critical to achieving high fill factors, notably because of the injector and matching section dynamics.

  1. Extending the Nonlinear-Beam-Dynamics Concept of 1D Fixed Points to 2D Fixed Lines

    CERN Document Server

    Franchetti, G.

    2015-01-01

    The origin of nonlinear dynamics traces back to the study of the dynamics of planets with the seminal work of Poincaré at the end of the nineteenth century: Les Méthodes Nouvelles de la Mécanique Céleste, Vols. 1–3 (Gauthier Villars, Paris, 1899). In his work he introduced a methodology fruitful for investigating the dynamical properties of complex systems, which led to the so-called “Poincaré surface of section,” which allows one to capture the global dynamical properties of a system, characterized by fixed points and separatrices with respect to regular and chaotic motion. For two-dimensional phase space (one degree of freedom) this approach has been extremely useful and applied to particle accelerators for controlling their beam dynamics as of the second half of the twentieth century.We describe here an extension of the concept of 1D fixed points to fixed lines in two dimensions. These structures become the fundamental entities for characterizing the nonlinear motion in the four-dimensional phas...

  2. Nucleation phenomena during molecular beam epitaxy of GaN observed by line-of-sight quadrupole mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Koblmueller, G.; Averbeck, R.; Riechert, H. [Infineon Technologies AG, Corporate Research Photonics, Otto-Hahn-Ring 6, 81739 Munich (Germany); Pongratz, P. [Vienna University of Technology, Institute of Solid State Physics, Wiedner Hauptstrasse 8-10, 1040 Vienna (Austria)

    2002-12-16

    We investigate nucleation and growth phenomena during molecular beam epitaxy of GaN on sapphire, 6H-SiC and GaN templates using in situ line-of-sight quadrupole mass spectrometry. Moreover, this method allows the quantitative study of nucleation phenomena by monitoring desorption processes. Heteroepitaxial growth of GaN on sapphire and 6H-SiC faces a high energy barrier to nucleation giving rise to a substantial Ga desorption during the initial phase of nucleation. The amount of initial Ga desorption in heteroepitaxy is independent of the chosen substrate material and is as high as 8 {+-} 1.5 nm equivalent GaN thickness. Once critical-sized islands have nucleated they grow three-dimensional (3D) leading to a quadratic increase of the GaN coverage and finally to a steady growth rate after coalescence, as also determined by Rutherford backscattering and atomic force microscopy. In contrast, homoepitaxy on Ga- and N-face GaN templates is distinguished by immediate nucleation. (Abstract Copyright [2002], Wiley Periodicals, Inc.)

  3. FABRICATION AND REPAIR OF ION SOURCE COMPONENTS IN THE 80 keV NEUTRAL BEAM LINES FOR DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    GRUNLOH,H.J; BUSATH,J.L; CALLIS,R.W; CHIU,H.K; DiMARTINO,M; HONG,R; KLASEN,R; MOELLER,C.P; ROBINSON,J.I; STRECKERT,H.H; TAO,R; TRESTER,P.W

    2003-10-01

    OAK-B135 After 8 years of operation, leaks began to develop in critical components of the ion sources of the 80 keV neutral beam lines in DIII-D. Operational adjustments were made that seemed to remedy the problems, but five years later leaks began occurring again, this time with greater frequency. Failures occurred in the stainless steel bellows and molybdenum rails of the grid rail modules as well as in the Langmuir probes. Failure analyses identified several root causes of the leaks and operational adjustments were again made to mitigate the problems, but the rash of failures depleted the program's supply of spare grid rail modules and probes and removed one of the ion sources from regular operation. Fifteen years after their original fabrication, the ion source components were no longer commercially available. In 2001, a program was initiated to fabricate new grid rail modules, including new molybdenum grid rails, bellows, and stainless steel grid rail holders, as well as new Langmuir probes. In parallel, components removed from service due to leaks were to be repaired with new rails and bellows and returned to service. An overview of the root causes of the service failures is offered, details of the repair processes are described, and a summary and evaluation of the fabrication procedures for the new molybdenum rails, grid modules, and Langmuir probes are given.

  4. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  5. Collins fragmentation function for pions and kaons in a spectator model

    Energy Technology Data Exchange (ETDEWEB)

    Bacchetta, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Gamberg, L.P. [Penn State Univ., Berks, PA (United States). Dept. of Physics; Goldstein, G.R. [Tufts Univ., Medford, MA (United States). Dept. of Physics and Astronomy; Mukherjee, A. [Indian Institute of Technology Bombay, Mumbai (India). Physics Dept.

    2007-07-15

    We calculate the Collins fragmentation function in the framework of a spectator model with pseudoscalar pion-quark coupling and a Gaussian form factor at the vertex. We determine the model parameters by fitting the unpolarized fragmentation function for pions and kaons. We show that the Collins function for the pions in this model is in reasonable agreement with recent parametrizations obtained by fits of the available data. In addition, we compute for the first time the Collins function for the kaons. (orig.)

  6. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W. P.; Assmann, R.; Decker, F.-J.; Hogan, M. J.; Iverson, R.; Siemann, R. H.; Walz, D. (and others)

    2001-10-01

    Emissions produced or initiated by a 30-GeV electron beam propagating through a {approx}1-m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  7. Measurements of Radiation Near An Atomic Spectral Line From the Interaction of a 30-GeV Electron Beam And a Long Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W.P.; /LBL, Berkeley; Assmann, R.; Decker, F.J.; Hogan, M.J.; Iverson, R.; Siemann, R.H.; Walz, D.; Whittum, D.; /SLAC; Blue, B.; Clayton, C.; Joshi, C.; Marsh, K.A.; Mori, W.B.; Wang, S.; /UCLA; Katsouleas, T.; Lee, S.; Muggli, P.; /Southern California U.

    2005-09-12

    Emissions produced or initiated by a 30 GeV electron beam propagating through a {approx}1 m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma; estimates of plasma and neutral density have been extracted. Increases in visible background radiation consistent with increased plasma recombination emissions due to dissipation of wakefields were simultaneously measured.

  8. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.E.; Chattopadhyay, S.; Esarey, E.; Leemans, W.P.; Assmann, R.; Decker, F.-J.; Hogan, M.J.; Iverson, R.; Siemann, R.H.; Walz, D.; Whittum, D.; Blue, B.; Clayton, C; Joshi, C.; Marsh, K.A.; Mori, W.B.; Wang, S.; Katsouleas, T.; Lee, S.; Muggli, P.

    2000-10-31

    Emissions produced or initiated by a 30 GeV electron beam propagating through a {approx} 1 m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creating of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  9. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Science.gov (United States)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W. P.; Assmann, R.; Decker, F.-J.; Hogan, M. J.; Iverson, R.; Siemann, R. H.; Walz, D.; Whittum, D.; Blue, B.; Clayton, C.; Joshi, C.; Marsh, K. A.; Mori, W. B.; Wang, S.; Katsouleas, T.; Lee, S.; Muggli, P.

    2001-10-01

    Emissions produced or initiated by a 30-GeV electron beam propagating through a ~1-m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  10. Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy.

    Science.gov (United States)

    Zheng, Dandan; Zhang, Qinghui; Liang, Xiaoying; Zhu, Xiaofeng; Verma, Vivek; Wang, Shuo; Zhou, Sumin

    2016-07-08

    In lung stereotactic body radiotherapy (SBRT) cases, the pencil beam (PB) dose calculation algorithm is known to overestimate target dose as compared to the more accurate Monte Carlo (MC) algorithm. We investigated whether changing the normalized prescription isodose line affected the magnitude of MC vs. PB target dose differences. Forty-eight patient plans and twenty virtual-tumor phantom plans were studied. For patient plans, four alternative plans prescribed to 60%, 70%, 80%, and 90% isodose lines were each created for 12 patients who previously received lung SBRT treatments. Using 6 MV dynamic conformal arcs, the plans were individually optimized to achieve similar dose coverage and conformity for all plans of the same patient, albeit at the different prescription levels. These plans, having used a PB algorithm, were all recalculated with MC to compare the target dose differences. The relative MC vs. PB target dose variations were investigated by comparing PTV D95, Dmean, and D5 loss at the four prescription levels. The MC-to-PB ratio of the plan heterogeneity index (HI) was also evaluated and compared among different isodose levels. To definitively demonstrate the cause of the isodose line dependence, a simulated phantom study was conducted using simple, spherical virtual tumors planned with uniform block margins. The tumor size and beam energy were also altered in the phantom study to investigate the interplay between these confounding factors and the isodose line effect. The magnitude of the target dose overestimation by PB was greater for higher prescription isodose levels. The MC vs. PB reduction in the target dose coverage indices, D95 and V100 of PTV, were found to monotonically increase with increasing isodose lines from 60% to 90%, resulting in more pronounced target dose coverage deficiency at higher isodose prescription levels. No isodose level-dependent trend was observed for the dose errors in the target mean or high dose indices, Dmean or D5. The

  11. W.K.H. Panofsky Prize in Experimental Particle Physics Talk: Kaons Redux- Seeking New Physics with Rare Decays of Kaons

    Science.gov (United States)

    Bryman, Douglas

    2011-04-01

    Studies of rare decays of kaons have been important in establishing the current picture of particle physics and in constraining hypothetical new approaches which go beyond the Standard Model to deal with its known deficiencies. Experimental capabilities have increased in concert with theoretical understanding making this approach to searching for new physics more viable than ever and essential, even in the era of the LHC. In this talk, I will discuss the most interesting and incisive rare kaon decay experiments, particularly K+ -->π+ ν ν andKL0 -->π0 ν ν , emphasizing the prospects for major advancements in the near term and at future high intensity proton accelerators.

  12. Role of the Coulomb interaction in the flow and the azimuthal distribution of kaons from heavy ion reactions

    CERN Document Server

    Wang, Z S; Fuchs, C; Maheswari, V S U; Kosov, D S; Faessler, Amand

    1998-01-01

    Coulomb final-state interaction of positive charged kaons in heavy ion reactions and its impact on the kaon transverse flow and the kaon azimuthal distribution are investigated within the framework of QMD (Quantum Molecular Dynamics) model. The Coulomb interaction is found to tend to draw the flow of kaons away from that of nucleons and lead to a more isotropic azimuthal distribution of kaons in the target rapidity region. The recent FOPI data have been analyzed by taking into accout both the Coulomb interaction and a kaon in-medium potential of the strong interaction. It is found that both the calculated kaon flows with only the Coulomb interaction and with both the Coulomb interaction and the strong potential agree within the error bars with the data. The kaon azimuthal distribution exhibits asymmetries of similar magnitude in both theoretical approaches. This means, the inclusion of the Coulomb potential makes it more difficult to extract information of the kaon mean field potential in nuclear matter from ...

  13. The Eurisol report. A feasibility study for a European isotope-separation-on-line radioactive ion beam facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-01

    The Eurisol project aims at a preliminary design study of the next-generation European isotope separation on-line (ISOL) radioactive ion beam (RIB) facility. In this document, the scientific case of high-intensity RIBs using the ISOL method is first summarised, more details being given in appendix A. It includes: 1) the study of atomic nuclei under extreme and so-far unexplored conditions of composition (i.e. as a function of the numbers of protons and neutrons, or the so-called isospin), rotational angular velocity (or spin), density and temperature, 2) the investigation of the nucleosynthesis of heavy elements in the Universe, an important part of nuclear astrophysics, 3) a study of the properties of the fundamental interactions which govern the properties of the universe, and in particular of the violation of some of their symmetries, 4) potential applications of RIBs in solid-state physics and in nuclear medicine, for example, where completely new fields could be opened up by the availability of high-intensity RIBs produced by the ISOL method. The proposed Eurisol facility is then presented, with particular emphasis on its main components: the driver accelerator, the target/ion-source assembly, the mass-selection system and post-accelerator, and the required scientific instrumentation. Special details of these components are given in appendices B to E, respectively. The estimates of the costs of the Eurisol, construction and running costs, have been performed in as much details as is presently possible. The total capital cost (installation manpower cost included) of the project is estimated to be of the order of 630 million Euros within 20%. In general, experience has shown that operational costs per annum for large accelerator facilities are about 10% of the capital cost. (A.C.)

  14. Beam tests with the CALICE tungsten analog hadronic calorimeter prototype

    CERN Document Server

    Dannheim, D; van der Kraaij, E

    2012-01-01

    The CALICE Analog Hadronic Calorimeter prototype has been equipped with layers of tungsten absorber. Together with the MICROMEGAS and T3B exper- iments the calorimeter was operated in test beams at the CERN PS and SPS with mixed beams of muons, electrons, pions, kaons and protons in an energy range from 1 to 300 GeV. This note describes the experimental configurations and data taking conditions.

  15. Free vibration analysis of straight-line beam regarded as distributed system by combining Wittrick-Williams algorithm and transfer dynamic stiffness coefficient method

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myung Soo; Yang, Kyong Uk [Chonnam National University, Yeosu (Korea, Republic of); Kondou, Takahiro [Kyushu University, Fukuoka (Japan); Bonkobara, Yasuhiro [University of Miyazaki, Miyazaki (Japan)

    2016-03-15

    We developed a method for analyzing the free vibration of a structure regarded as a distributed system, by combining the Wittrick-Williams algorithm and the transfer dynamic stiffness coefficient method. A computational algorithm was formulated for analyzing the free vibration of a straight-line beam regarded as a distributed system, to explain the concept of the developed method. To verify the effectiveness of the developed method, the natural frequencies of straight-line beams were computed using the finite element method, transfer matrix method, transfer dynamic stiffness coefficient method, the exact solution, and the developed method. By comparing the computational results of the developed method with those of the other methods, we confirmed that the developed method exhibited superior performance over the other methods in terms of computational accuracy, cost and user convenience.

  16. Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment

    Science.gov (United States)

    Sheftman, D.; Gupta, D.; Roche, T.; Thompson, M. C.; Giammanco, F.; Conti, F.; Marsili, P.; Moreno, C. D.

    2016-11-01

    Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field-reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements. Results of these measurements provide the jet ion temperature and axial velocity, electron density, and high frequency density fluctuations.

  17. Separated exclusive kaon production cross sections up to Q2=2.1 GeV2 and the kaon form factor

    Science.gov (United States)

    Carmignotto, Marco; Horn, Tanja

    2017-01-01

    Electromagnetic form factors are a key observable in probing hadronic structure, providing us with important information about underlying physical quantities related to nonperturbative QCD. Light mesons composed of a valence quark-antiquark pair can be described by a single electric form factor and have been shown to be a great laboratory for these studies. Using electroproduction experiments, a successful program was developed at Jefferson Laboratory for probing the charged pion form factor in the regime of Q2 up to 2.45 GeV2. This provided a first glimpse at a possible transition from the nonperturbative to the perturbative regime, and also information on the structure of the pion. The kaon is the next lightest existing hadron, providing an interesting channel for assessing the strangeness degree of freedom with mesons. Although the kaon is relatively unexploited to date, there are promising results from experiments of the 6 GeV era of Jefferson Laboratory with potential for kaon form factor extractions. In this talk we will present the recent analysis of the t-channel kaon cross section and discuss the relative contribution of longitudinal and transverse photons to the cross section up to Q2 values of 2.1 GeV2 and prospects for form factor extractions. Supported in part by NSF grants PHY-1306227 and PHY-1306418 and by the JSA Graduate Fellowship.

  18. Mott dissociation of pions and kaons in hot quark matter

    CERN Document Server

    Dubinin, A; Blaschke, D; Wergieluk, A

    2016-01-01

    We describe the Mott dissociation of pions and kaons within a Beth-Uhlenbeck approach based on the PNJL model, which allows for a unified description of bound, resonant and scattering states. Within this model we evaluate the temperature and chemical potential dependent modification of the phase shifts both in the pseudoscalar and scalar isovector meson channels for $N_f=2+1$ quark flavors. We show that the character change of the pseudoscalar bound states to resonances in the continuum at the Mott transition temperature is signaled by a jump of the phase shift at the threshold from $\\pi$ to zero, in accordance with the Levinson theorem. In particular, we demonstrate the importance of accounting for the scattering continuum states, which ensures that the total phase shift in each of the meson channels vanishes at high energies, thus eliminating mesonic correlations from the thermodynamics at high temperatures. In this way, we prove that the present approach provides a unified description of the transition fro...

  19. Two-photon production of charged pion and kaon pairs

    CERN Document Server

    Dominick, J; Sanghera, S; Shelkov, V; Skwarnicki, T; Stroynowski, R; Volobuev, I P; Wei, G; Zadorozhny, P; Artuso, M; Goldberg, M; He, D; Horwitz, N; Kennett, R; Mountain, R; Moneti, G C; Muheim, F; Mukhin, Y; Playfer, S; Rozen, Y; Stone, S; Thulasidas, M; Vasseur, G; Zhu, G; Bartelt, J; Csorna, S E; Egyed, Z; Jain, V; Kinoshita, K; Edwards, K W; Ogg, M; Britton, D I; Hyatt, E R F; MacFarlane, D B; Patel, P M; Akerib, D S; Barish, B C; Chadha, M; Chan, S; Cowen, D F; Eigen, G; Miller, J S; O'Grady, C; Urheim, J; Weinstein, A J; Acosta, D; Athanas, M; Masek, G E; Paar, H P; Sivertz, M; Gronberg, J B; Kutschke, R; Menary, S R; Morrison, R J; Nakanishi, S; Nelson, H N; Nelson, T K; Qiao, C; Richman, J D; Ryd, A; Tajima, H; Sperka, D; Witherell, M S; Procario, M; Balest, R; Cho, K; Daoudi, M; Ford, W T; Johnson, D R; Lingel, K; Lohner, M; Rankin, P; Smith, J G; Alexander, J P; Bebek, C; Berkelman, K; Bloom, K; Browder, T E; Cassel, David G; Cho, H A; Coffman, D M; Drell, P S; Ehrlich, R; Gaidarev, P B; Galik, R S; García-Sciveres, M; Geiser, B; Gittelman, B; Gray, S W; Hartill, D L; Heltsley, B K; Jones, C D; Jones, S L; Kandaswamy, J; Katayama, N; Kim, P C; Kreinick, D L; Ludwig, G S; Masui, J; Mevissen, J; Mistry, N B; Ng, C R; Nordberg, E; Patterson, J R; Peterson, D; Riley, D; Salman, S; Sapper, M; Würthwein, F; Avery, P; Freyberger, A P; Rodríguez, J; Stephens, R; Yang, S; Yelton, J; Cinabro, D; Henderson, S; Liu, T; Saulnier, M; Wilson, R; Yamamoto, H; Bergfeld, T; Eisenstein, B I; Gollin, G; Ong, B; Palmer, M; Selen, M; Thaler, J J; Sadoff, A J; Ammar, R; Ball, S; Baringer, P; Bean, A; Besson, D; Coppage, D; Copty, N K; Davis, R; Hancock, N; Kelly, M; Kwak, N; Lam, H; Kubota, Y; Lattery, M; Nelson, J K; Patton, S; Perticone, D; Poling, R A; Savinov, V; Schrenk, S; Wang, R; Alam, M S; Kim, I J; Nemati, B; O'Neill, J J; Severini, H; Sun, C R; Zoeller, M M; Crawford, G; Daubenmier, C M; Fulton, R; Fujino, D; Gan, K K; Honscheid, K; Kagan, H; Kass, R; Lee, J; Malchow, R L; Skovpen, Y; Sung, M; White, C; Butler, F; Fu, X; Kalbfleisch, G R; Ross, W R; Skubic, P L; Snow, J; Wang, P L; Wood, M; Brown, D N; Fast, J; McIlwain, R L; Miao, T; Miller, D H; Modesitt, M; Payne, D; Shibata, E I; Shipsey, I P J; Wang Pei Ning; Battle, M; Ernst, J; Kwon, Y; Roberts, S; Thorndike, E H; Wang, C H

    1994-01-01

    A measurement of the cross section for the combined two-photon production of charged pion and kaon pairs is performed using 1.2~\\rm fb^{-1} of data collected by the CLEO II detector at the Cornell Electron Storage Ring. The cross section is measured at invariant masses of the two-photon system between 1.5 and 5.0~GeV/c^2, and at scattering angles more than 53^\\circ away from the \\gamma\\gamma collision axis in the \\gamma\\gamma center-of-mass frame. The large background of leptonic events is suppressed by utilizing the CsI calorimeter in conjunction with the muon chamber system. The reported cross section is compared with leading order QCD models as well as previous experiments. In particular, although the functional dependence of the measured cross section disagrees with leading order QCD at small values of the two-photon invariant mass, the data show a transition to perturbative behavior at an invariant mass of approximately 2.5~GeV/c^2. hardcopies with figures can be obtained by writing to to: Pam Morehouse ...

  20. KEK workshop on kaon, muon and neutrino physics: summary

    Energy Technology Data Exchange (ETDEWEB)

    Bryman, D. [TRIUMF, Vancouver, BC (Canada)

    1998-02-01

    A broad range of current work and future possibilities associated with the interactions and properties of kaons, muons and neutrinos was discussed at the workshop with particular emphasis on possibilities for the Japanese Hadron Facility. The recent evidence for the flavor changing neutral current reaction K{sup +} {yields} {pi}{sup +}{nu}{nu}-bar was presented along with prospects for future work. New experiments at BNL, KEK and Fermilab are being developed to study the especially attractive CP-violating channel K{sub L}{sup 0} {yields} {pi}{sup 0}{nu}{nu}-bar. Very sensitive searches for lepton flavor violation in muon decays and muon capture, and measurements aiming at uncovering non-standard model T-violating effects in K{sub {mu}3} decay were also discussed. Several neutrino experiments continue to observe deficits in rates relative to expectations, possibly indicating evidence for oscillations, and promising new initiatives such at the K2K project at KEK are in the works to explore these matters further. Many of the issues raised at the workshop are relevant to the search for an understanding of the three generation spectrum of quarks and leptons i.e. the generation puzzle. (author)

  1. Semileptonic Kaon Decay in Staggered Chiral Perturbation Theory

    CERN Document Server

    Bernard, C; Gámiz, E

    2013-01-01

    The determination of $\\vert V_{us}\\vert$ from kaon semileptonic decays requires the value of the form factor $f_+(q^2=0)$, which can be calculated precisely on the lattice. We provide the one-loop partially quenched staggered chiral perturbation theory expressions that may be employed to analyze staggered simulations of $f_+(q^2)$ with three light flavors. We consider both the case of a mixed action, where the valence and sea sectors have different staggered actions, and the standard case where these actions are the same. The momentum transfer $q^2$ of the form factor is allowed to have an arbitrary value. We give results for the generic situation where the $u$, $d$, and $s$ quark masses are all different, $N_f=1+1+1$, and for the isospin limit, $N_f=2+1$. The expression we obtain for $f_+(q^2)$ is independent of the mass of the (valence) spectator quark. In the limit of vanishing lattice spacing, our results reduce to the one-loop continuum partially quenched expression for $f_+(q^2)$, which has not previous...

  2. Polarization Observables for Kaon Photoproduction from Polarized Protons

    CERN Document Server

    Walford, Natalie K

    2013-01-01

    The search for undiscovered excited states of the nucleon continues to be a focus of experiments at Jefferson Lab.Recent LQCD calculations have confirmed long-standing quark-model predictions of many more states than have so far been identified.A large effort for the N-star program has been launched using the CLAS detector to provide the database that will allow nearly model-independent partial wave analyses to be carried out in the search for such states. Polarization observables play a crucial role in this effort, as they are essential in disentangling overlapping resonant and non-resonant amplitudes. In 2010, double-polarization data were taken at JLab using circularly polarized photons incident on a transversely polarized frozen-spin butanol target. Our current analysis yields preliminary data of the T and F asymmetries for kaon photoproduction final states, which are compared to predictions of recent multipole analyses. This work is the first of its kind and will significantly broaden the world database ...

  3. Kaon experiments at CERN: recent results and prospects

    CERN Document Server

    Goudzovski, Evgueni

    2016-11-29

    The NA48/2 and NA62-$R_K$ experiments at the CERN SPS collected large samples of charged kaon decays in flight in 2003--07. The data analysis is still on-going (with over 20 publications produced so far); the recent results from these experiments are presented. A new upper limit on the rate of a lepton number violating decay $K^\\pm\\to\\pi^\\mp\\mu^\\pm\\mu^\\pm$ is reported: $\\mathcal{B} < 8.6\\times 10^{-11}$ at 90\\% CL. Searches for heavy sterile neutrino $N_4$ and neutral scalar resonances ($\\chi$) in $K^\\pm\\to\\pi\\mu\\mu$ decays are reported. Upper limits on the products $\\mathcal{B}(K^\\pm\\to\\mu^\\pm N_4)\\mathcal{B}(N_4\\to\\pi^\\mp\\mu^\\pm)$ and $\\mathcal{B}(K^\\pm\\to\\pi^\\pm \\chi)\\mathcal{B}(\\chi\\to\\mu^+\\mu^-)$ are set in the range $10^{-10}$ to $10^{-9}$ for resonance lifetimes up to 100~ps. A preliminary measurement of the electromagnetic transition form factor slope of the $\\pi^0$ from $1.05\\times 10^6$ fully reconstructed $\\pi^0\\to\\gamma e^+e^-$ decays is presented: the obtained result $a = (3.70 \\pm 0.53_\\text{...

  4. Kaon experiments at CERN: recent results and prospects

    Science.gov (United States)

    Goudzovski, Evgueni

    2016-11-01

    The NA48/2 and NA62-RK experiments at the CERN SPS collected large samples of charged kaon decays in flight in 2003-07. The data analysis is still on-going (with over 20 publications produced so far); the recent results from these experiments are presented. A new upper limit on the rate of a lepton number violating decay K± →π∓μ±μ± is reported: B< 8.6×10-11 at 90% CL. Searches for heavy sterile neutrino N4 and neutral scalar resonances (χ) in K± → πμμ decays are reported. Upper limits on the products B(K± → μ±N4)B(N4 → π∓μ±) and B(K± → π±χ)B(χ → μ+μ-) are set in the range 10-10 to 10-9 for resonance lifetimes up to 100 ps. A preliminary measurement of the electromagnetic transition form factor slope of the π0 from 1.05 × 106 fully reconstructed π0 → γe+e- decays is presented: the obtained result a = (3:70 ± 0:53stat ± 0:36syst) × 10-2 represents the first observation of a non-zero slope in the time-like region of momentum transfer.

  5. Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions

    CERN Document Server

    Kasarinov, N Y; Kalagin, I V; Kazacha, V I

    2002-01-01

    The gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensions by current signals from the scanner needle are adduced. The method of the emittance recovery for axial-symmetric ion beam is set for the case when the space charge effect is essential. The algorithm for tuning of the quadrupole lenses in the injection channel of the cyclotron DC-72 for obtaining the axial-symmetric ion beam is proposed. The evaluations of the expected accuracy of the proposed method for the emittance recovery have been carried out.

  6. Induced polarization of Λ(1116) in kaon electroproduction

    Energy Technology Data Exchange (ETDEWEB)

    Gabrielyan, M.; Raue, B. A.; Carman, D. S.; Park, K.; Adhikari, K. P.; Adikaram, D.; Amaryan, M. J.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Baltzell, N. A.; Battaglieri, M.; Baturin, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Cao, T.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Cortes, O.; Crede, V.; D' Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dupre, R.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fleming, J. A.; Forest, T. A.; Garillon, B.; Gevorgyan, N.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hattawy, M.; Hicks, K.; Ho, D.; Holtrop, M.; Hughes, S. M.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jiang, H.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Kim, W.; Klein, F. J.; Koirala, S.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Lenisa, P.; Levine, W. I.; Livingston, K.; MacGregor, I. J. D.; Mayer, M.; McKinnon, B.; Meyer, C. A.; Mestayer, M. D.; Mirazita, M.; Mokeev, V.; Moody, C. I.; Moutarde, H.; Movsisyan, A.; Munevar, E.; Munoz Camacho, C.; Nadel-Turonski, P.; Niccolai, S.; Niculescu, G.; Osipenko, M.; Pappalardo, L. L.; Paremuzyan, R.; Pasyuk, E.; Peng, P.; Phelps, W.; Phillips, J. J.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Rimal, D.; Ripani, M.; Rizzo, A.; Sabatié, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Simonyan, A.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strakovsky, I. I.; Strauch, S.; Sytnik, V.; Tang, W.; Ungaro, M.; Vlassov, A. V.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Zachariou, N.; Zana, L.; Zhang, J.; Zonta, I.

    2014-09-01

    We have measured the induced polarization of the Λ(1116) in the reaction ep→e'K+Λ, detecting the scattered e' and K+ in the final state along with the proton from the decay Λ→pπ-.The present study used the CEBAF Large Acceptance Spectrometer (CLAS), which allowed for a large kinematic acceptance in invariant energy W (1.6≤W≤2.7 GeV) and covered the full range of the kaon production angle at an average momentum transfer Q2=1.90 GeV2.In this experiment a 5.50 GeV electron beam was incident upon an unpolarized liquid-hydrogen target. We have mapped out the W and kaon production angle dependencies of the induced polarization and found striking differences from photoproduction data over most of the kinematic range studied. However, we also found that the induced polarization is essentially Q2 independent in our kinematic domain, suggesting that somewhere below the Q2 covered here there must be a strong Q2 dependence. Along with previously published photo- and electroproduction cross sections and polarization observables, these data are needed for the development of models, such as effective field theories, and as input to coupled-channel analyses that can provide evidence of previously unobserved s-channel resonances.

  7. Probing lepton flavour (universality) violation at NA62 and future kaon experiments

    CERN Document Server

    Tunstall, Lewis C; D'Ambrosio, Giancarlo; Hoferichter, Martin

    2016-01-01

    Recent results from the LHC's first run have revealed intriguing departures from lepton flavour universality in the semi-leptonic decays of $B$-mesons. We discuss the complementary role that rare kaon decays can provide in testing new physics explanations of these flavour anomalies. In the framework of minimal flavour violation, we relate the chiral low-energy constants involved in $K\\to\\pi\\ell\\ell'$ and $K\\to\\ell\\ell'$ ($\\ell = \\mu \\mbox{ or } e$) with the new physics Wilson coefficients of the $b\\to s$ effective Hamiltonian. We comment on the determination of these low-energy constants at NA62 and future kaon experiments, as well as the required improvements in sensitivity necessary to test the $B$-physics anomalies in the kaon sector.

  8. The Dynamical Nonlocality of Neutral Kaons and the Kaonic Quantum Eraser

    CERN Document Server

    Hiesmayr, Beatrix C

    2010-01-01

    Testing quantum foundations for systems in high energy physics gets currently more and more attention e.g. witnessed for entangled neutral K-mesons by the approved programme of the KLOE collaboration at the accelerator facility DAPHNE (Frascati, Italy). We focus on this quantum system in high energy physics and discuss two topics, Bell inequalities and the kaonic quantum eraser, and show how the neutral kaon system differs from systems of ordinary matter and light. In detail, we show a relation of the imbalance of matter and antimatter to the violation of a Bell inequality and discuss another Bell inequality which is maximally violated for a non-maximally entangled state though neutral kaons can be considered as two state systems. We compare in general this system in high energy physics with bipartite qudits. Last but not least we review the quantum marking and eraser procedure and explain why neutral kaons offer more eraser possibilities than usual quantum systems.

  9. Contribution of CPLEAR to the physics of the neutral-kaon system

    Energy Technology Data Exchange (ETDEWEB)

    Angelopoulos, A.; Apostolakis, A.; Aslanides, E.; Backenstoss, G.; Bargassa, P.; Behnke, O.; Benelli, A.; Bertin, V.; Blanc, F.; Bloch, P.; Carlson, P.; Carroll, M.; Cawley, E.; Chertok, M.B.; Danielsson, M.; Dejardin, M.; Derre, J.; Ealet, A.; Eleftheriadis, C.A.; Faravel, L.; Fetscher, W.; Fidecaro, M.; Filipcic, A.; Francis, D.; Fry, J.; Gabathuler, E.; Gamet, R.; Gerber, H.-J.; Go, A.; Haselden, A.; Hayman, P.J.; Henry-Couannier, F.; Hollander, R.W.; Jon-And, K.; Kettle, P.-R.; Kokkas, P.; Kreuger, R.; Le Gac, R.; Leimgruber, F.; Mandic, I.; Manthos, N.; Marel, G.; Mikuz, M.; Miller, J.; Montanet, F.; Muller, A.; Nakada, T.; Pagels, B.; Papadopoulos, I.; Pavlopoulos, P.; Polivka, G.; Rickenbach, R.; Roberts, B.L.; Ruf, T.; Schaefer, M.; Schaller, L.A.; Schietinger, T.; Schopper, A.; Schune, P.; Tauscher, L.; Thibault, C.; Touchard, F.; Touramanis, C.; Van Eijk, C.W.E.; Vlachos, S.; Weber, P.; Wigger, O.; Wolter, M.; Zavrtanik, D.; Zimmerman, D

    1999-04-01

    We report the results of the CPLEAR experiment on CP-, T- and CPT-symmetries in the neutral kaon system. CP-violation parameters are given for different decay channels. For the first time T-violation is measured by a direct method using semileptonic decays. The CPT symmetry in the kaons decays is tested through the parameters Im({delta}), from the Bell-Steinberger relation, with a precision of 10{sup -5} and Re({delta}) with a precision of a few 10{sup -4} (two order of magnitude better than the previous measurement). These two measurements allow us to bound the difference in mass and width of K{sup 0} and K-bar{sup 0} to be equal within 10{sup -18} GeV. In the limit of CPT invariance in the neutral kaon decays, the K{sup 0} and K-bar{sup 0} masses are equal within 10{sup -19} GeV.

  10. Study of charged kaon production in three-prong tau decays

    Energy Technology Data Exchange (ETDEWEB)

    Hao Wei

    1996-02-01

    This thesis presents the measurement of kaon production in 3-prong {tau} decays. The data sample of Z{sup 0} events is used that was recorded with the DELPHI detector at LEP in 1992, 1993 and 1994. Charged kaons in the {tau} decay are identified on a track-by-track basis using the Ring Imaging Cherenkov detector (RICH). The branching ratios of {tau}{sup -}{yields}K{sup -}K{sup +}{pi}{sup -} (neutrals) {nu}{sub {tau}} and {tau}{sup -}{yields}K{sup -}{pi}{sup +}{pi}{sup -} (neutrals) {nu}{sub {tau}} are determined. The resonance structure of these two decays is studied. Evidence for a simple QCD process of kaon pair production in {tau} decay is discussed. (orig.).

  11. Measurements of Discrete Symmetries in the Neutral Kaon System with the CPLEAR (PS195) Experiment

    CERN Document Server

    Ruf, Thomas

    2015-01-01

    The antiproton storage ring LEAR offered unique opportunities to study the symmetries which exist between matter and antimatter. At variance with other approaches at this facility, CPLEAR was an experiment devoted to the study of T, CPT and CP symmetries in the neutral kaon system. It measured with high precision the time evolution of initially strangeness-tagged $K^0$ and $\\bar{K}^0$ states to determine the size of violations with respect to these symmetries in the context of a systematic study. In parallel, limits concerning quantum-mechanical predictions (EPR paradox, coherence of the wave function) or the equivalence principle of general relativity have been obtained. This article will first discuss briefly the unique low energy antiproton storage ring LEAR followed by a description of the CPLEAR experiment, including the basic formalism necessary to understand the time evolution of a neutral kaon state and the main results related to measurements of discrete symmetries in the neutral kaon system. An exce...

  12. Kaon-Nucleon systems and their interactions in the Skyrme model

    CERN Document Server

    Ezoe, Takashi

    2016-01-01

    We study kaon-nucleon systems in the Skyrme model in a method based on the bound state approach of Callan-Klebanov but with the kaon around the physical nucleon of the rotating hedgehog. This corresponds to the variation after projection, reversing the order of semiclassical quantization of $1/N_c$ expansion. The method, however, is considered to be suited to the study of weakly interacting kaon-nucleon systems including loosely $\\bar{K}N$ bound states such as $\\Lambda(1405)$. We have found a bound state with binding energy of order ten MeV, consistent with the observed state. We also discuss the $\\bar{K}N$ interaction and find that it consists of an attraction in the middle range and a repulsion in the short range.

  13. Constrains on $L_\\mu-L_\\tau$ Gauge Interactions from Rare Kaon Decay

    CERN Document Server

    Ibe, Masahiro; Suzuki, Motoo

    2016-01-01

    The model with the $L_\\mu -L_\\tau$ gauge symmetry is the least constrained model as a resolution to the disagreement of the muon anomalous magnetic moment between the theoretical prediction and the experimental result. In this paper, we discuss how well the $L_\\mu - L_\\tau$ model can be constrained by looking for the decay of the charged kaon associated with the $L_\\mu-L_\\tau$ gauge boson. More concretely, we consider searches for single muon tracks from the decays of stopped charged kaons as performed in the E949 experiment. As a result, we find that favored parameter region for the muon anomalous magnetic moment can be tested by using $10$ times larger number of stopped charged kaons and about $100$ times better photon rejection rate than the E949 experiment.

  14. Bose–Einstein condensation of anti-kaons and neutron star twins

    Indian Academy of Sciences (India)

    Sarmistha Banik; Debades Bandyopadhyay

    2003-05-01

    We investigate the role of Bose–Einstein condensation (BEC) of anti-kaons on the equation of state (EoS) and other properties of compact stars. In the framework of relativistic mean field model we determine the EoS for -stable hyperon matter and compare it to the situation when anti-kaons condense in the system. We observe that anti-kaon condensates soften the EoS, thereby lowering the maximum mass of the stars. We also demonstrate that the presence of antikaon condensates in the high density core of compact stars may lead to a new mass sequence beyond white dwarf and neutron stars. The limiting mass of the new sequence stars is nearly equal to that of neutron star branch though they have distinctly different radii and compositions. They are called neutron star twins.

  15. The LHC SSS cold mass inside the cryostat. The complexity of the bus-bars for the power supply of the magnets and cryogenic links can be seen. The two apertures in the centre will house the beam lines

    CERN Multimedia

    2003-01-01

    The LHC SSS cold mass inside the cryostat. The complexity of the bus-bars for the power supply of the magnets and cryogenic links can be seen. The two apertures in the centre will house the beam lines

  16. Kaon matrix elements and CP violation from quenched lattice QCD

    Science.gov (United States)

    Cristian, Calin-Radu

    We report the results of a calculation of the K → pipi matrix elements relevant for the DeltaI = 1/2 rule and epsilon '/epsilon in quenched lattice QCD using domain wall fermions at a fixed lattice spacing of a-1 ˜ 2 GeV. Working in the three-quark effective theory, where only the u, d and s quarks enter and which is known perturbatively to next-to-leading order; we calculate the lattice K → pi and K → |0> matrix elements of dimension six, four-fermion operators. Through lowest order chiral perturbation theory these yield K → pipi matrix elements, which we then normalize to continuum values through a non-perturbative renormalization technique. For the Delta I = 1/2 rule we find a value of 25.3 +/- 1.8 (statistical error only) compared to the experimental value of 22.2, with individual isospin amplitudes 10--20% below the experimental values. For epsilon '/epsilon; using known central values for standard model parameters, we calculate (-4.0 +/- 2.3) x 10-4 (statistical error only) compared to the current experimental average of (17.2 +/- 1.8) x 10-4. Because we find a large cancellation between the I = 0 and I = 2 contributions to epsilon'/epsilon, the result may be very sensitive to the approximations employed. Among these are the use of: quenched QCD, lowest order chiral perturbation theory and continuum perturbation theory below 1.3 GeV. We have also calculated the kaon B parameter, BK and find BK(2 GeV) = 0.532(11). Although currently unable to give a reliable systematic error; we have control over statistical errors and more simulations will yield information about the effects of the approximations on this first-principles determination of these important quantities.

  17. Charged kaon production by coherent scattering of neutrinos and antineutrinos on nuclei

    CERN Document Server

    Alvarez-Ruso, L; Simo, I Ruiz; Valverde, M; Vacas, M J Vicente

    2012-01-01

    With the aim of achieving a better and more complete understanding of neutrino interactions with nuclear targets, the coherent production of charged kaons induced by neutrinos and antineutrinos is investigated in the energy range of some of the current neutrino experiments. We follow a microscopic approach which, at the nucleon level, incorporates the most important mechanisms allowed by the chiral symmetry breaking pattern of QCD. The distortion of the outgoing (anti)kaon is taken into account by solving the Klein-Gordon equation with realistic optical potentials. Angular and momentum distributions are studied, as well as the energy and nuclear dependence of the total cross section.

  18. Two-kaon correlations in central Pb + Pb collisions at 158 A GeV/c

    CERN Document Server

    Sugitate, T; Bøggild, H; Boissevain, J; Christiansen, P H L; Conin, L; Dodd, J; Erazmus, B; Esumi, S; Fabjan, Christian Wolfgang; Ferenc, D; Franz, A; Gaardhøje, J J; Hansen, A G; Hansen, O; Hardtke, D; van Hecke, H; Holzer, E B; Humanic, T J; Hummel, P; Jacak, B V; Kaimi, K; Kaneta, M; Kohama, T; Kopytine, M; Leltchouk, M; Ljubicic, A; Lörstad, B; Maeda, N; Martin, L; Medvedev, A; Murray, M; Ohnishi, H; Paic, G; Pandey, S U; Piuz, François; Pluta, J; Polychronakos, V; Potekhin, M; Poulard, G; Reichhold, D; Sakaguchi, A; Schmidt-Sørensen, J; Simon-Gillo, J; Sondheim, W; Sullivan, J P; Sumi, Y; Willis, W J; Wolf, K; Xu, N; Zachary, D S

    2001-01-01

    Two-particle interferometry of positive kaons is studied in Pb + Pb collisions at mean transverse momenta $\\approx 0.25$ and 0.91 GeV/c. A three-dimensional analysis was applied to the lower $p_T$ data, while a two-dimensional analysis was used for the higher $p_T$ data. We find that the source size parameters are consistent with the $m_T$ scaling curve observed in pion correlation measurements in the same collisions, and that the duration time of kaon emission is consistent with zero within the experimental sensitivity.

  19. Pion, Kaon, Proton and Antiproton Production in Proton-Proton Collisions

    Science.gov (United States)

    Norbury, John W.; Blattnig, Steve R.

    2008-01-01

    Inclusive pion, kaon, proton, and antiproton production from proton-proton collisions is studied at a variety of proton energies. Various available parameterizations of Lorentz-invariant differential cross sections as a function of transverse momentum and rapidity are compared with experimental data. The Badhwar and Alper parameterizations are moderately satisfactory for charged pion production. The Badhwar parameterization provides the best fit for charged kaon production. For proton production, the Alper parameterization is best, and for antiproton production the Carey parameterization works best. However, no parameterization is able to fully account for all the data.

  20. The quantum CP-violating kaon system reproduced in the electronic laboratory

    Science.gov (United States)

    Caruso, M.; Fanchiotti, H.; García Canal, C. A.; Mayosky, M.; Veiga, A.

    2016-11-01

    The equivalence between the Schrödinger dynamics of a quantum system with a finite number of basis states and a classical dynamics is realized in terms of electric networks. The isomorphism that connects in a univocal way both dynamical systems was applied to the case of neutral mesons, kaons in particular, and the class of electric networks univocally related to the quantum system was analysed. Moreover, under CPT invariance, the relevant ɛ parameter that measures CP violation in the kaon system is reinterpreted in terms of network parameters. All these results were explicitly shown by means of both a numerical simulation of the implied networks and by constructing the corresponding circuits.