WorldWideScience

Sample records for kaman 40-kw wind

  1. Northeast Utilities' participation in the Kaman/NASA wind power program

    Science.gov (United States)

    Lotker, M.

    1975-01-01

    The role of Northeast Utilities in the Kaman/NASA large wind generator study is reviewed. The participation falls into four principal areas: (1) technical assistance; (2) economic analysis; (3) applications; and (4) institutional and legal. A model for the economic viability of wind power is presented.

  2. Wind Turbine Generator System Acoustic Noise Test Report for the Gaia Wind 11-kW Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Huskey, A.

    2011-11-01

    This report details the acoustic noise test conducted on the Gaia-Wind 11-kW wind turbine at the National Wind Technology Center. The test turbine is a two- bladed, downwind wind turbine with a rated power of 11 kW. The test turbine was tested in accordance with the International Electrotechnical Commission standard, IEC 61400-11 Ed 2.1 2006-11 Wind Turbine Generator Systems -- Part 11 Acoustic Noise Measurement Techniques.

  3. Design, performance, and economics of 50-kW and 500-kW vertical axis wind turbines

    Science.gov (United States)

    Schienbein, L. A.; Malcolm, D. J.

    1983-11-01

    A review of the development and performance of the DAF Indal 50-kW vertical axis Darrieus wind turbine shows that a high level of technical development and reliability has been achieved. Features of the drive train, braking and control systems are discussed and performance details are presented. Details are also presented of a 500-kW VAWT that is currently in production. A discussion of the economics of both the 50-kW and 500-kW VAWTs is included, showing the effects of charge rate, installed cost, operating cost, performance, and efficiency.

  4. Kurokawa 150-kW wind turbine generator demonstration; 150 kW Kurokawa furyoku hatsudensho ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, M; Shinohara, M; Sugiyama, T [Kansai Electric Power Co. Inc., Osaka (Japan)

    1996-10-27

    This paper presents the 150kW wind turbine generator erected at a site near Kurokawa dam lake of Kansai Electric Power Co. in Hyogo prefecture. This generator is composed of a horizontal-axis propeller with 3 blades of 27m in diameter and 36/27rpm, and a tower of 30m high. Harmony with the environment was also considered because of the site in a natural park area. Its demonstration test started in Oct. 1996 at annual mean wind velocity of 2m/s. Soft start was realized by controlling inrush current and preventing voltage drop in system interconnection by use of a thyristor circuit. The dual operation system was adopted of a 30kW small generator at lower wind velocity and a 150kW large one at higher velocity. Two kinds of brakes are used, and rotor revolution was reduced by air brake (blade tip spoiler). Mechanical disk brake works for the stopped rotor or emergency stopping. Even if the wind turbine was stopped by exterior factor, if no anomaly of the turbine is found, it automatically re-starts after removal of the factor. The generator is controlled from a remote control station 150km apart through NTT communication line. 6 figs., 2 tabs.

  5. Design, performance and economics of the DAF Indal 50 kW and 375 kW vertical axis wind turbine

    Science.gov (United States)

    Schienbein, L. A.; Malcolm, D. J.

    1982-03-01

    A review of the development and performance of the DAF Indal 50 kW vertical axis Darrieus wind turbines shows that a high level of technical development and reliability has been achieved. Features of the drive train, braking and control systems are discussed and performance details are presented. A description is given of a wind-diesel hybrid presently being tested. Details are also presented of a 375 kW VAWT planned for production in late 1982. A discussion of the economics of both the 50 kW and 375 kW VAWTs is included, showing the effects of charge rate, installed cost, operating cost, performance and efficiency. The energy outputs are translated into diesel fuel cost savings for remote communities.

  6. A 200-kW wind turbine generator conceptual design study

    Science.gov (United States)

    1979-01-01

    A conceptual design study was conducted to define a 200 kW wind turbine power system configuration for remote applications. The goal was to attain an energy cost of 1 to 2 cents per kilowatt-hour at a 14-mph site (mean average wind velocity at an altitude of 30 ft.) The costs of the Clayton, New Mexico, Mod-OA (200-kW) were used to identify the components, subsystems, and other factors that were high in cost and thus candidates for cost reduction. Efforts devoted to developing component and subsystem concepts and ideas resulted in a machine concept that is considerably simpler, lighter in weight, and lower in cost than the present Mod-OA wind turbines. In this report are described the various innovations that contributed to the lower cost and lighter weight design as well as the method used to calculate the cost of energy.

  7. Design study of wind turbines 50 kW to 3000 kW for electric utility applications. Volume 2: Analysis and design

    Science.gov (United States)

    1976-01-01

    All possible overall system configurations, operating modes, and subsystem concepts for a wind turbine configuration for cost effective generation of electrical power were evaluated for both technical feasibility and compatibility with utility networks, as well as for economic attractiveness. A design optimization computer code was developed to determine the cost sensitivity of the various design features, and thus establish the configuration and design conditions that would minimize the generated energy costs. The preliminary designs of both a 500 kW unit and a 1500 kW unit operating in a 12 mph and 18 mph median wind speed respectively, were developed. The various design features and components evaluated are described, and the rationale employed to select the final design configuration is given. All pertinent technical performance data and component cost data is included. The costs of all major subassemblies are estimated and the resultant energy costs for both the 500 kW and 1500 kW units are calculated.

  8. Design study of wind turbines 50 kW to 3000 kW for electric utility applications. Volume 1: Summary report

    Science.gov (United States)

    1976-01-01

    Wind turbine configurations that would lead to generation of electrical power in a cost effective manner were considered. All possible overall system configurationss, operating modes, and sybsystem concepts were evaluated for both technical feasibility and compatibility with utility networks, as well as for economic attractiveness. A design optimization computer code was developed to determine the cost sensitivity of the various design features, and thus establish the configuration and design conditions that would minimize the generated energy costs. The preliminary designs of both a 500 kW unit and a 1500 kW unit operating in a 12 mph and 18 mph median wind speed respectively, were developed. The rationale employed and the key findings are summarized.

  9. Survey of the small (300 W to 300 kW) wind turbine market in Canada

    International Nuclear Information System (INIS)

    2005-01-01

    The significant growth in the Canadian wind power industry over the past decade has resulted in an increased number of large utility-scale wind farms appearing across Canada. Although large wind turbines are often acknowledged as a mature technology that can provide clean, reliable and economically competitive power, smaller wind turbines have had relatively little documentation in comparison. The aim of this report was to provide a profile of the Canadian market for small wind turbines (SWTs), divided into 3 categories: mini wind turbines with a rated power output from 300 watts to 1000 watts; small wind turbines up to 30 kW; and medium-sized wind turbines up to 300 kW. Study findings were based on interviews with industry experts and a comprehensive survey of 135 companies involved in the Canadian SWT industry. Details of annual sales and total installed capacity were provided, as well as a summary of key SWT markets. An overview of Canadian market demand and international SWT manufacturing capacity was presented. Opportunities and barriers were examined. It was observed that experiences in the United States have indicated that SWTs are more successful when combined with enabling policies, market incentives, and education and awareness raising. The U.S. small wind industry has estimated that in the near future, the SWT industry could supply 50,000 MW, employ 10,000 people and generate $1 billion per year. A number of opportunities for the promotion of the small wind industry in Canada were reviewed, including the niche manufacturing sector in the 20 kW to 50 kW range. Issues concerning the economic benefits of a SWT manufacturing industry were examined. It was suggested that as the SWT markets grow and mature, turbine prices are expected to fall and turbine effectiveness and reliability will increase. An SWT promotional strategy was outlined with incentives in 4 areas: (1) market development; (2) policy development; (3) technology development; and (4) education

  10. Wind turbine test Vestas V27-225 kW

    Energy Technology Data Exchange (ETDEWEB)

    Markkilde Petersen, S

    1990-10-15

    The report describes fundamental measurements performed on a Vestas-V27-225 kW pitch regulated wind turbine. The measurements carried out and reported here comprises the power output, system efficiency, energy production, transmission efficiency, rotor power, rotor efficiency, air-brakes efficiency, structural dynamics, loads at cut-in and braking, yaw error statistics, flapwise root bending moment and rotor thrust. (author).

  11. Consideration concerning the costs of the 300 kW wind units developed in Romania

    International Nuclear Information System (INIS)

    Gyulai, F.; Bej, A.

    1995-01-01

    A demonstrative wind farm with four research units, 300 kW each, is in developing stage in Romania. The article shows economic analysis of these experimental wind units and their cost structure focusing in component costs, performance, manufacturing technology and installing work. (author)

  12. Consideration concerning the costs of the 300 kW wind units developed in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Gyulai, F; Bej, A [Technical Univ. of Timisoara (Romania). Wind Energy Research Center

    1996-12-31

    A demonstrative wind farm with four research units, 300 kW each, is in developing stage in Romania. The article shows economic analysis of these experimental wind units and their cost structure focusing in component costs, performance, manufacturing technology and installing work. (author)

  13. Consideration concerning the costs of the 300 kW wind units developed in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Gyulai, F.; Bej, A. [Technical Univ. of Timisoara (Romania). Wind Energy Research Center

    1995-12-31

    A demonstrative wind farm with four research units, 300 kW each, is in developing stage in Romania. The article shows economic analysis of these experimental wind units and their cost structure focusing in component costs, performance, manufacturing technology and installing work. (author)

  14. Enertech 2-kW high-reliability wind system. Phase II. Fabrication and testing

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J A; Johnson, B A

    1981-06-01

    A high-reliability wind machine rated for 2 kW in a 9 m/s wind has been developed. Activities are summarized that are centered on the fabrication and testing of prototypes of the wind machine. The test results verified that the wind machine met the power output specification and that the variable-pitch rotor effectively controlled the rotor speed for wind speeds up to 50 mph. Three prototypes of the wind machine were shipped to the Rocky Flats test center in September through November of 1979. Work was also performed to reduce the start-up wind speed. The start-up wind speed to the Enertech facility has been reduced to 4.5 m/s.

  15. Controlled Velocity Testing of an 8-kW Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Sencenbaugh, J.; Acker, B.

    2001-07-31

    This paper describes a case study of the controlled-velocity test of an 8-kW wind turbine. The turbine was developed in response to the U.S. Department of Energy's small wind turbine program. As background, the prototype development is discussed. The turbine mechanical and electrical components are described. The turbine was tested on a flatbed truck and driven down an airfield runway at constant relative wind speed. Horizontal furling was used to control over-speed. Various parameters were changed to determine their effects on furling. The testing showed that the machine had insufficient rotor offset for adequate furling. Also, a rotor resonance problem was discovered and remedied. Problems associated with taking the measurements made it difficult to determine if the truck test was a suitable method for code validation. However, qualitative observations gleaned from the testing justified the effort.

  16. Stand-alone version of the 11kW Gaia wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.

    2004-01-01

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of thefast controllers of the unit. Controllers...... assessment and controller design a dynamic performance assessment model has been developed....

  17. Design study of wind turbines, 50 kW to 3000 kW for electric utility applications: Executive summary

    Science.gov (United States)

    1977-01-01

    Preliminary designs of low power (50 to 500 kW) and high power (500 to 3000 kW) wind generator systems (WGS) for electric utility applications were developed. These designs provide the bases for detail design, fabrication, and experimental demonstration testing of these units at selected utility sites. Several feasible WGS configurations were evaluated, and the concept offering the lowest energy cost potential and minimum technical risk for utility applications was selected. The selected concept was optimized utilizing a parametric computer program prepared for this purpose. The utility requirements evaluation task examined the economic, operational and institutional factors affecting the WGS in a utility environment, and provided additional guidance for the preliminary design effort. Results of the conceptual design task indicated that a rotor operating at constant speed, driving an AC generator through a gear transmission is the most cost effective WGS configuration.

  18. Power train analysis for the DOE/NASA 100-kW wind turbine generator

    Science.gov (United States)

    Seidel, R. C.; Gold, H.; Wenzel, L. M.

    1978-01-01

    Progress in explaining variations of power experienced in the on-line operation of a 100 kW experimental wind turbine-generator is reported. Data are presented that show the oscillations tend to be characteristic of a wind-driven synchronous generator because of low torsional damping in the power train, resonances of its large structure, and excitation by unsteady and nonuniform wind flow. The report includes dynamic analysis of the drive-train torsion, the generator, passive driveline damping, and active pitch control as well as correlation with experimental recordings. The analysis assumes one machine on an infinite bus with constant generator-field excitation.

  19. Noise Emission of a 200 kW Vertical Axis Wind Turbine

    Directory of Open Access Journals (Sweden)

    Erik Möllerström

    2015-12-01

    Full Text Available The noise emission from a vertical axis wind turbine (VAWT has been investigated. A noise measurement campaign on a 200 kW straight-bladed VAWT has been conducted, and the result has been compared to a semi-empirical model for turbulent-boundary-layer trailing edge (TBL-TE noise. The noise emission from the wind turbine was measured, at wind speed 8 m/s, 10 m above ground, to 96.2 dBA. At this wind speed, the turbine was stalling as it was run at a tip speed lower than optimal due to constructional constraints. The noise emission at a wind speed of 6 m/s, 10 m above ground was measured while operating at optimum tip speed and was found to be 94.1 dBA. A comparison with similar size horizontal axis wind turbines (HAWTs indicates a noise emission at the absolute bottom of the range. Furthermore, it is clear from the analysis that the turbulent-boundary-layer trailing-edge noise, as modeled here, is much lower than the measured levels, which suggests that other mechanisms are likely to be important, such as inflow turbulence.

  20. Design study of wind turbines 50 kW to 3000 kW for electric utility applications: Analysis and design

    Science.gov (United States)

    1976-01-01

    In the conceptual design task, several feasible wind generator systems (WGS) configurations were evaluated, and the concept offering the lowest energy cost potential and minimum technical risk for utility applications was selected. In the optimization task, the selected concept was optimized utilizing a parametric computer program prepared for this purpose. In the preliminary design task, the optimized selected concept was designed and analyzed in detail. The utility requirements evaluation task examined the economic, operational, and institutional factors affecting the WGS in a utility environment, and provided additional guidance for the preliminary design effort. Results of the conceptual design task indicated that a rotor operating at constant speed, driving an AC generator through a gear transmission is the most cost effective WGS configuration. The optimization task results led to the selection of a 500 kW rating for the low power WGS and a 1500 kW rating for the high power WGS.

  1. Design of a 3 kW wind turbine generator with thin airfoil blades

    Energy Technology Data Exchange (ETDEWEB)

    Ameku, Kazumasa; Nagai, Baku M.; Roy, Jitendro Nath [Faculty of Mechanical Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Okinawa 903-0213 (Japan)

    2008-09-15

    Three blades of a 3 kW prototype wind turbine generator were designed with thin airfoil and a tip speed ratio of 3. The wind turbine has been controlled via two control methods: the variable pitch angle and by regulation of the field current of the generator and examined under real wind conditions. The characteristics of the thin airfoil, called ''Seven arcs thin airfoil'' named so because the airfoil is composed of seven circular arcs, are analyzed with the airfoil design and analysis program XFOIL. The thin airfoil blade is designed and calculated by blade element and momentum theory. The performance characteristics of the machine such as rotational speed, generator output as well as stability for wind speed changes are described. In the case of average wind speeds of 10 m/s and a maximum of 19 m/s, the automatically controlled wind turbine ran safely through rough wind conditions and showed an average generator output of 1105 W and a power coefficient 0.14. (author)

  2. Monitoring and economics of a 60 kW wind turbine generator on a pig farm in Scotland

    International Nuclear Information System (INIS)

    Saluja, G.S.

    1990-01-01

    Low cost monitoring of a 60 kW wind turbine generator connected to an intensive pig farm in the Grampian area of Scotland is described. A method of calculating the economic implications of installing a small grid-connected wind turbine generator at a farm is based on monitored data, electricity bills and energy production is proposed. (author)

  3. Output characteristics of 40 kW photovoltaic power generation system in ICT; Ibaraki kosen ni okeru 40 kW taiyoko hatsuden shisutemu no shutsuryoku tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Sekiguchi, N. [Ibaraki National College of Tech., Ibaraki (Japan); Tani, T. [Science University of Tokyo, Tokyo (Japan)

    1999-11-25

    The photovoltaic power generation system consists of photovoltaic array and power conditioner of the utility connected system. The photovoltaic array parallelly constitutes 18 serial 30 of the modules of 540 sheets, and there is the generating capacity of largest 40 kW. The power conditioner uses 10 kW four units, and it is tracking with function of the maximum output point. This report examined the unconformable rate of photovoltaic array maximum output operating voltage, current and power in simulation and power conditioner input. (author)

  4. Analysis of the Response of a 600 kW Stall Controlled Wind Turbine in Complex Terrain

    Energy Technology Data Exchange (ETDEWEB)

    Cuerva, A.; Bercebal, D.; De la Cruz, S.; Lopez-Diez, S.; Lopez-Roque, V.; Vazquez-Aguado, A.; Marti, I.; Marchante, M.; Navarro, J. [CIEMAT. Madrid (Spain)

    1998-12-31

    This work presents a detailed analysis of the operating characteristics of a 600 kW rated power wind turbine installed in complex terrain. The description of the experimental set up and analysis system is included. The relationships between parameters that describe the wind turbine response and the environmental conditions are established via high level statistical analysis, fatigue analysis and analysis is the frequency domain. Dimensionless factors are calculated to explain the intrinsic response of the structure before stochastic and deterministic wind conditions, independently from its size and wind intensity. Finally, conclusions are presented regarding the parameters that affect the loading state and power production of the machine. (Author) 12 refs.

  5. Analysis of the Response of a 600 kW Stall Controlled Wind Turbine in Complex Terrain

    International Nuclear Information System (INIS)

    Cuerva, A.; Bercebal, D.; De La Cruz, M.; Lopez-Diez, S.; Lopez-Roque, V.; Vazquez-Aguado, A.; Marti, I.; Marchante, M.; Navarro, J.

    1998-01-01

    This work presents a detailed analysis of the operating characteristics of a 600 kW rated power wind turbine installed in complex terrain. The description of the experimental set up and analysis system is included. The relationships between parameters that describe the wind turbine response and the environmental conditions are established via high level statistical analysis, fatigue analysis and analysis in the frequency domain. Dimension less factors are calculated to explain the intrinsic response of the structure before stochastic and deterministic wind conditions, independently from its size and wind intensity. Finally, conclusions are presented regarding the parameters that affect the loading state and power production of the machine. (Author) 12 refs

  6. 40 kW Stirling Engine for Solid Fuel

    DEFF Research Database (Denmark)

    Carlsen, Henrik; Trærup, Jens

    1996-01-01

    The external combustion in a Stirling engine makes it very attractive for utilisation of solid fuels in decentralised combined heat and power (CHP) plants. Only a few projects have concentrated on the development of Stirling engines specifically for biomass. In this project, a Stirling engine has...... been designed primarily for utilisation of wood chips. Maximum shaft power is 40 kW corresponding to an electric output of 36 kW. Biomass needs more space in the combustion chamber compared to gas and liquid fuels, and a large heat transfer area is necessary. The design of the new Stirling engine has...... been adapted to the special demands of combustion of wood chips, resulting in a large engine compared to engines for gas or liquid fuels. The engine has four-cylinders arranged in a square. The design is made as a hermetic unit, where the alternator is built into the pressurised crankcase so...

  7. Performance of a 3 kW wind turbine generator with variable pitch control system

    International Nuclear Information System (INIS)

    Nagai, Baku M.; Ameku, Kazumasa; Roy, Jitendro Nath

    2009-01-01

    A prototype 3 kW horizontal upwind type wind turbine generator of 4 m in diameter has been designed and examined under real wind conditions. The machine was designed based on the concept that even small wind turbines should have a variable pitch control system just as large wind turbines, especially in Japan where typhoons occur at least once a year. A characteristic of the machine is the use of a worm and gear system with a stepping motor installed in the center of the hub, and the rotational main shaft. The machine is constructed with no mechanical breaking system so as to avoid damage from strong winds. In a storm, the wind turbine is slowed down by adjusting the pitch angle and the maximum electrical load. Usually the machine is controlled at several stages depending on the rotational speed of the blades. Two control methods have been applied: the variable pitch angle, and regulation of the generator field current. The characteristics of the generator under each rotational speed and field current are first investigated in the laboratory. This paper describes the performances of the wind turbine in terms of the functions of wind turbine rotational speed, generated outputs, and its stability for wind speed changes. The expected performances of the machine have been confirmed under real wind conditions and compared with numerical simulation results. The wind turbine showed a power coefficient of 0.257 under the average wind speed of 7.3 m/s.

  8. Wind power development field test project at Maruyama-machi. Close survey on wind conditions; Maruyamamachi ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A survey was made on wind conditions in Maruyama-machi, Awa-gun, Chiba prefecture, on the assumption that a wind power generation system was installed therein. The survey period was one year from Oct., 1998 to Sept., 1999. The observations were carried out on the average wind velocity, average wind direction, standard deviation of velocity, and the maximum instantaneous wind velocity. With a fixed point observation at 20 m above ground, and with the minimum observation time unit of 10 minutes, an average value during the 10 minutes was determined as the measurement of each category. However, the maximum instantaneous wind velocity was determined on the measurement with the minimum observation time unit of 2 seconds. The average annual wind velocity was 3.5 m/s, the maximum wind velocity during the period was 27 m/s, and the wind axis was WSW-ENE, with the total occurrence rate of the wind direction 44.1%. The intensity of turbulence was 0.23 at a wind velocity of 2.0 m/s or above and was 0.22 at 4.0 m/s or above. An estimated annual operation rate of a windmill was 40-60% using the rated value of a 150 kW, 300 kW and 750 kW class windmills. (NEDO)

  9. Stand-alone version of the 11kW Gaia wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.; Blaabjerg, F.

    2004-09-15

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of the fast controllers of the unit. Controllers are designed and a prototype is built for testing. The report documents the performance of the prototype through measurements done on the full scale prototype installed in a test facility where it has been tested both as a standalone unit and in parallel with a diesel genset. For system wide power quality assessment and controller design a dynamic performance assessment model has been developed. (au)

  10. Transient analysis of unbalanced short circuits of the ERDA-NASA 100 kW wind turbine alternator

    Science.gov (United States)

    Hwang, H. H.; Gilbert, L. J.

    1976-01-01

    Unbalanced short-circuit faults on the alternator of the ERDA-NASA Mod-O100-kW experimental wind turbine are studied. For each case, complete solutions for armature, field, and damper-circuit currents; short-circuit torque; and open-phase voltage are derived directly by a mathematical analysis. Formulated results are tabulated. For the Mod-O wind turbine alternator, numerical calculations are given, and results are presented by graphs. Comparisons for significant points among the more important cases are summarized. For these cases the transients are found to be potentially severe. The effect of the alternator neutral-to-ground impedance is evaluated.

  11. Gear fatigue damage for a 500 kW wind turbine exposed to increasing turbulence using a flexible multibody model

    DEFF Research Database (Denmark)

    Jørgensen, Martin Felix; Pedersen, Niels Leergaard; Sørensen, Jens Nørkær

    2014-01-01

    This paper investigates gear tooth fatigue damage in a 500 kW wind turbine using FLEX5 and own multibody code. FLEX5 provides the physical wind eld, rotor and generator torque and the multibody code is used for obtaining gear tooth reaction forces in the planetary gearbox. Dierent turbulence levels...... and therefore increased fatigue damage levels. This article contributes to a better understanding of gear fatigue damage when turbulence is increased (e.g. in the center of large wind farms or at places where turbulence is pronounced)....

  12. Potentials of wind power

    International Nuclear Information System (INIS)

    Bezrukikh, P.P.; Bezrukikh, P.P.

    2000-01-01

    The ecological advantages of the wind power facilities (WPF) are considered. The possibilities of small WPF, generating the capacity from 40 W up to 10 kW, are discussed. The basic technical data on the national and foreign small WPF are presented. The combined wind power systems are considered. Special attention is paid to the most perspective wind-diesel systems, which provide for all possible versions of the electro-power supply. Useful recommendations and information on the wind power engineering are given for those, who decided to build up a wind facility [ru

  13. Gear fatigue damage for a 500 kW wind turbine exposed to increasing turbulence using a flexible multibody model

    Directory of Open Access Journals (Sweden)

    Martin Felix Jørgensen

    2014-04-01

    Full Text Available This paper investigates gear tooth fatigue damage in a 500 kW wind turbine using FLEX5 and own multibody code. FLEX5 provides the physical wind field, rotor and generator torque and the multibody code is used for obtaining gear tooth reaction forces in the planetary gearbox. Different turbulence levels are considered and the accumulated fatigue damage levels are compared. An example where the turbulence/fatigue sensitivity could be important, is in the middle of a big wind farm. Interior wind turbines in large wind farms will always operate in the wake of other wind turbines, causing increased turbulence and therefore increased fatigue damage levels. This article contributes to a better understanding of gear fatigue damage when turbulence is increased (e.g. in the center of large wind farms or at places where turbulence is pronounced.

  14. Performance evaluation of small wind turbines for off grid applications in Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Hadhrami, Luai M.

    2014-01-01

    Highlights: • Sixteen HAWT and 8 VAWT performance evaluations for s wind measurement site. • HAWT were found to be more efficient than VAWT. • Higher energy yields during high load demands. • PCF’s of up to 54% could be achieved. • Highest energy increase for hub height change from 20 to 30 m. - Abstract: The study evaluated the energy output and plant capacity factor (PCF) of small wind turbines in the category of 1–3 kW, 5–10 kW, 15–20 kW and 50–80 kW rated powers. Furthermore, the effect of hub height on energy output and the PCF has been studied to recommend suitable hub height for different type of applications and load requirements. To achieve the set objectives, hourly average wind speed data measured at 10, 20, 30, and 40 m and wind direction at 30 and 40 m above ground level during July 01, 2006 to July 10, 2008 has been utilized. Highest percentage change in annual energy yield (AEY) was obtained for an increase in hub height of 10 m from 20 to 30 m for both horizontal and vertical wind turbines chosen in the present study. The next best AEY was obtained while increasing hub height from 10 to 15 m. Horizontal axis wind turbines Fortis Passat with PCF of 44.4% at 15 m hub height, Aeolos-H 5 kW with PCF of 20% at 20 m hub height, and CF6e with PCF of 32.5% at 20 m hub height are recommended for different load requirements. Similarly, vertical axis wind turbines UGE Vision 2 kW with PCF of 8.9% at 15 m hub height, Aeolos-V-2 5 kW with PCF of 20.6% at 20 m hub height, and UGE-9M 10 kW with PCF of 14.2% at 30 m hub height are also recommended for various ranges of loads. Horizontal axis wind turbines were found generally more efficient than the vertical axis wind turbines in the present case

  15. Design and operating experience on the U.S. Department of Energy Experimental Mod-O 100 kW Wind Turbine

    Science.gov (United States)

    Glasgow, J. C.; Birchenough, A. G.

    1978-01-01

    The Mod-O 100 kW Experimental Wind Turbine was designed and fabricated by NASA, as part of the Federal Wind Energy Program, to assess technology requirements and engineering problems of large wind turbines. The machine became operational in October 1975 and has demonstrated successful operation in all of its design modes. During the course of its operations the machine has generated a wealth of experimental data and has served as a prototype developmental test bed for the Mod-OA operational wind turbines which are currently used on utility networks. This paper describes the mechanical and control systems as they evolved in operational tests and describes some of the experience with various systems in the downwind rotor configuration.

  16. MOD-0A 200 kW wind turbine generator design and analysis report

    Science.gov (United States)

    Anderson, T. S.; Bodenschatz, C. A.; Eggers, A. G.; Hughes, P. S.; Lampe, R. F.; Lipner, M. H.; Schornhorst, J. R.

    1980-01-01

    The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented.

  17. Performance and Potential Study of 10kW Wind Turbine Generator for 6 Cities in Malaysia

    OpenAIRE

    Mustaqimah Mustaqimah

    2013-01-01

    ABSTRACT. This study presents an analysis of the optimization by using HOMER software and financial viability of 10 kW wind turbine generator (WTG) through grid connected system for six different locations in Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka and Labuan). Assessment criteria comprised Total Net Present Cost (TNPC), and Cost of Energy ( COE ). The HOMER ( National Renewable Energy laboratory, US) was utilized as the assessment tool with modeling performed with hourly load ...

  18. Mechatronic modeling of a 750kW fixed-speed wind energy conversion system using the Bond Graph Approach.

    Science.gov (United States)

    Khaouch, Zakaria; Zekraoui, Mustapha; Bengourram, Jamaa; Kouider, Nourreeddine; Mabrouki, Mustapha

    2016-11-01

    In this paper, we would like to focus on modeling main parts of the wind turbines (blades, gearbox, tower, generator and pitching system) from a mechatronics viewpoint using the Bond-Graph Approach (BGA). Then, these parts are combined together in order to simulate the complete system. Moreover, the real dynamic behavior of the wind turbine is taken into account and with the new model; final load simulation is more realistic offering benefits and reliable system performance. This model can be used to develop control algorithms to reduce fatigue loads and enhance power production. Different simulations are carried-out in order to validate the proposed wind turbine model, using real data provided in the open literature (blade profile and gearbox parameters for a 750 kW wind turbine). Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Design and dynamic simulation of a fixed pitch 56 kW wind turbine drive train with a continuously variable transmission

    Science.gov (United States)

    Gallo, C.; Kasuba, R.; Pintz, A.; Spring, J.

    1986-01-01

    The dynamic analysis of a horizontal axis fixed pitch wind turbine generator (WTG) rated at 56 kW is discussed. A mechanical Continuously Variable Transmission (CVT) was incorporated in the drive train to provide variable speed operation capability. One goal of the dynamic analysis was to determine if variable speed operation, by means of a mechanical CVT, is capable of capturing the transient power in the WTG/wind environment. Another goal was to determine the extent of power regulation possible with CVT operation.

  20. Danish wind power in Brazil. Part 2. Experience with Danish 75 kW wind turbine - the first modern turbine in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Husted Rich, N; Kildemoes Moeller, T

    1996-04-01

    In June of 1992, the first grid-connected wind turbine (75 kW, 12 m/s) in Brazil was installed in the complex terrain of the island of Fernando de Noronha in the northeastern part of the country. The objective was to install a Danish wind turbine in order to encourage the use of wind energy in Brazil and to demonstrate Danish wind technology with the view of opening up the Brazilian market for Danish windmills. It is claimed that the turbine, backed up by the media, attracted a certain amount of attention despite problems caused by the weakness of the electric grid on the island. The market in Brazil is still not ready for wind turbines and responsibility for any future wind energy policy is held by the political decision makers, so it is recommended that further demonstration projects be set up. The document presents a general view of the wind conditions and a view of the local electric power system with the aim of improving the potential for further installation of Danish wind turbines on the island. It proved difficult to obtain information on the performance of the windmill due to frequent rotations in the hierarchy of the state utility company CELPE, and the highly bureaucratic structure in general. It is stated that CELPE intends to install two more wind turbines on the island and that this could be a proof of recognition that technical problems that arose were caused by the unsatisfactory grid structure on the island and not related to faults in the wind turbine itself, and also a proof of their confidence in the idea of wind energy as a reliable source of electricity production. (AB)

  1. Operation result of 40kW class MCFC pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, H.; Hatori, S.; Hosaka, M.; Uematsu, H. [Ishikawajima-Harima Heavy Industries Co., Ltd., Tokyo (Japan)

    1996-12-31

    Ishikawajima-Harima Heavy Industries Co., Ltd. developed unique Molten Carbonate Fuel Cell (MCFC) system based on our original concept. To demonstrate the possibility of this system, based on MCFC technology of consigned research from New Energy and Industrial Technology Development Organization (NEDO) in Japan, we designed 40kW class MCFC pilot plant which had all equipments required as a power plant and constructed in our TO-2 Technical Center. This paper presents the test results of the plant.

  2. The economics of a variable speed wind-diesel

    International Nuclear Information System (INIS)

    Moll, W.

    1992-01-01

    A remote community power supply system generating over 1,000 kWH/d will have at least one diesel generator running all the time. If one or more wind turbine generators are added to such a system, the diesel generator will produce less power when wind speeds are adequate, but its fuel efficiency will gradually decrease as load decreases. In the variable speed wind/diesel concept, the diesel rpm is reduced with decreasing load and a high fuel efficiency is maintained over virtually the full power range. The outputs of the diesel and wind turbine generators are fed into an inverter which synthesizes a desired voltage wave-shape with controlled magnitude and frequency. The variable speed wind/diesel concept may make vertical axis wind turbines suitable for remote community power supply because the inverter effectively isolates the power ripple of the wind turbine. A possible wind/diesel system configuration using the variable speed concept is illustrated. The economics of a 50-kW variable speed diesel and a 80-kW variable speed wind turbine generator was analyzed. Going from a constant speed diesel generator to a variable speed generator operating at 55% capacity factor, a 6% fuel saving was achieved. Adding one 80-kW wind turbine increased fuel savings to 32% at 5 m/s wind speed, but the unit energy cost rose 8.5%. At 7 m/s wind speed, fuel savings were 59% and energy savings were 7.8%. Economics are better for a peaking variable speed 50-kW wind/diesel system added to an existing diesel system to extend the installed capacity. At 7 m/s wind speed the fuel savings translate into ca $40,000 over 10 y and purchase of a $150,000 diesel generator is postponed. 7 figs., 1 tab

  3. Performance and Potential Study of 10kW Wind Turbine Generator for 6 Cities in Malaysia

    Directory of Open Access Journals (Sweden)

    Mustaqimah Mustaqimah

    2013-04-01

    Full Text Available ABSTRACT. This study presents an analysis of the optimization by using HOMER software and financial viability of 10 kW wind turbine generator (WTG through grid connected system for six different locations in Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka and Labuan. Assessment criteria comprised Total Net Present Cost (TNPC, and Cost of Energy ( COE . The HOMER ( National Renewable Energy laboratory, US was utilized as the assessment tool with modeling performed with hourly load data input from six cities in Malaysia. The results demonstrate that WTG has the potential to supply significant power for small scale load in conjunction with the grid-electricity supply. Optimization modeling demonstrated that the TNPC for grid connected configuration is Mersing for the lowest TNPC among the other cities which is TNPC recorded at $ -28,436 and initial cost is about $ 20,000. This mean wind grid system in Mersing is very benefit be built and reduction in greenhouse gas emission of 9,452 kg/yr. Optimization modeling also showed that Mersing is the only one among other city had showed a high potential of WTG which produced energy at 85,326 kWh/yr and purchase grid only at 4,082 kWh/year. Kajian Kinerja dan Potensi Generator Turbin Angin 10kW untuk 6 kota di Malaysia ABSTRAK. Penelitian ini menyajikan analisis optimasi dengan menggunakan software HOMER dan kesesuaian biaya untuk generator turbin angin (wind turbine generator=WTG 10 kW sistem grid untuk enam lokasi yang berbeda di Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka dan Labuan. Kriteria penilaian terdiri Total Net Present Cost (TNPC dan Cost of Energy (COE. software HOMER (National Renewable Energy laboratory, US digunakan sebagai pemodelan dengan memasukkan data beban daya per jam dari enam kota tersebut. Hasil penelitian menunjukkan bahwa generator turbin angin (WTG memiliki potensi untuk memasok daya yang signifikan untuk beban kecil dalam hubungannya dengan pasokan grid

  4. Wind power development field test project at Okkobe-cho. Close survey on wind conditions; Okkobecho ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A survey was made on regional wind conditions on the assumption that a wind power generator was installed around Okkobe Rakuno-no-oka, Okkobe-cho, Monbetsu-gun, Hokkaido. The survey period was one year from Oct., 1998 to Sept., 1999. The observations were carried out on the average wind velocity, average wind direction, standard deviation of velocity, and the maximum instantaneous wind velocity. With a fixed point observation at 20 m above ground, and with the minimum observation time unit of 10 minutes, an average value during the 10 minutes was determined as the measurement of each category. However, the maximum instantaneous wind velocity was determined on the measurement with the minimum observation time unit of 2 seconds. The average wind velocity was 4.8 m/s, the maximum wind velocity during the period was 29.9 m/s, the prevailing wind direction was WSW (17.1%), the wind axis was WSW-ENE, and the total occurrence rate of wind direction was 51.1%. The intensity of turbulence was 0.19 at a wind velocity of 2.0 m/s or above and was 0.16 at 4.0 m/s or above. An estimated annual operation rate of a windmill was 59-77% using the rated value of a 150 kW, 300 kW and 750 kW class windmills. (NEDO)

  5. Wind power development field test project at Kodomari-mura 'Marinetopia'. Close survey on wind conditions; Kodomarimura Marinetopia ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A survey was made on wind conditions in Imabetsu-machi, Higashi Tsugaru-gun, Aomori prefecture, on the assumption that a wind power generation system was installed therein. The survey period was one year from Oct., 1998 to Sept., 1999. The observations were carried out on the average wind velocity, average wind direction, standard deviation of velocity, and the maximum instantaneous wind velocity. With a fixed point observation at 20 m above ground, and with the minimum observation time unit of 10 minutes, an average value during the 10 minutes was determined as the measurement of each category. However, the maximum instantaneous wind velocity was determined on the measurement with the minimum observation time unit of 2 seconds. The annual average wind velocity was 4.8 m/s, the maximum wind velocity during the period was 35 m/s, the prevailing wind direction was NW-WNW and ESE-SEW, and the occurrence rate of wind direction at the wind axis of NW-SE was 88.1%. The intensity of turbulence was 0.24 at a wind velocity of 2.0 m/s or above and was 0.20 at 4.0 m/s or above. An estimated annual operation rate of a windmill was 46-64% using the rated value of a 150 kW, 300 kW and 750 kW class windmills. (NEDO)

  6. Measurements of the Aerodynamic Normal Forces on a 12-kW Straight-Bladed Vertical Axis Wind Turbine

    Directory of Open Access Journals (Sweden)

    Eduard Dyachuk

    2015-08-01

    Full Text Available The knowledge of unsteady forces is necessary when designing vertical axis wind turbines (VAWTs. Measurement data for turbines operating at an open site are still very limited. The data obtained from wind tunnels or towing tanks can be used, but have limited applicability when designing large-scale VAWTs. This study presents experimental data on the normal forces of a 12-kW straight-bladed VAWT operated at an open site north of Uppsala, Sweden. The normal forces are measured with four single-axis load cells. The data are obtained for a wide range of tip speed ratios: from 1.7 to 4.6. The behavior of the normal forces is analyzed. The presented data can be used in validations of aerodynamic models and the mechanical design for VAWTs.

  7. Wind power development field test project at Rokkasho-mura, Aomori prefecture. Close survey on wind conditions; Aomoriken Rokkashomura ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A survey was made on wind conditions in Rokkasho-mura, Kamikita-gun, Aomori prefecture, on the assumption that a wind power generation system was installed therein. The survey period was one year from Oct., 1998 to Sept., 1999. The observations were carried out on the average wind velocity, average wind direction, standard deviation of velocity, and the maximum instantaneous wind velocity. With a fixed point observation at 20 m above ground, and with the minimum observation time unit of 10 minutes, an average value during the 10 minutes was determined as the measurement of each category. However, the maximum instantaneous wind velocity was determined on the measurement with the minimum observation time unit of 2 seconds. The annual average wind velocity was 4.6 m/s, the maximum wind velocity during the period was 26.0 m/s, the prevailing wind direction was NW (20.8%), WNW (18.0%), and SE (13.5%), and the total occurrence rate of wind direction at the wind axis of NW-SE was 75.7%. The intensity of turbulence was 0.25 at a wind velocity of 2.0 m/s or above and was 0.21 at 4.0 m/s or above. An estimated annual operation rate of a windmill was 59-72% using the rated value of a 150 kW, 300 kW and 750 kW class windmills. (NEDO)

  8. Directly driven generators for wind power applications

    Energy Technology Data Exchange (ETDEWEB)

    Lampola, P [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Electromechanics

    1996-12-31

    The article deals with an analysis of directly driven, low-speed wind generators. The generators studied were a permanent-magnet synchronous machine and an asynchronous machine. The machines were compared with a typical generator of a wind power plant. The electromagnetic optimization of the machines was done by the finite element method. The rated power of the generators was 500 kW and the rotational speed was 40 rpm. (author)

  9. Directly driven generators for wind power applications

    Energy Technology Data Exchange (ETDEWEB)

    Lampola, P. [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Electromechanics

    1995-12-31

    The article deals with an analysis of directly driven, low-speed wind generators. The generators studied were a permanent-magnet synchronous machine and an asynchronous machine. The machines were compared with a typical generator of a wind power plant. The electromagnetic optimization of the machines was done by the finite element method. The rated power of the generators was 500 kW and the rotational speed was 40 rpm. (author)

  10. The application of hydraulics in the 2,000 kW wind turbine generator

    Science.gov (United States)

    Onufreiczuk, S.

    1978-01-01

    A 2000 kW turbine generator using hydraulic power in two of its control systems is being built under the management of NASA Lewis Research Center. The hydraulic systems providing the control torques and forces for the yaw and blade pitch control systems are discussed. The yaw-drive-system hydraulic supply provides the power for positioning the nacelle so that the rotary axis is kept in line with the direction of the prevailing wind, as well as pressure to the yaw and high speed shaft brakes. The pitch-change-mechanism hydraulic system provides the actuation to the pitch change mechanism and permits feathering of the blades during an emergency situation. It operates in conjunction with the overall windmill computer system, with the feather control permitting slewing control flow to pass from the servo valve to the actuators without restriction.

  11. Field Testing of LIDAR-Assisted Feedforward Control Algorithms for Improved Speed Control and Fatigue Load Reduction on a 600-kW Wind Turbine: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Avishek A.; Bossanyi, Ervin A.; Scholbrock, Andrew K.; Fleming, Paul; Boquet, Mathieu; Krishnamurthy, Raghu

    2015-12-14

    A severe challenge in controlling wind turbines is ensuring controller performance in the presence of a stochastic and unknown wind field, relying on the response of the turbine to generate control actions. Recent technologies such as LIDAR, allow sensing of the wind field before it reaches the rotor. In this work a field-testing campaign to test LIDAR Assisted Control (LAC) has been undertaken on a 600-kW turbine using a fixed, five-beam LIDAR system. The campaign compared the performance of a baseline controller to four LACs with progressively lower levels of feedback using 35 hours of collected data.

  12. Report on the field test project for wind power development at Soyo Town (wind characteristics investigation); Soyomachi ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Wind characteristics are observed for a year at Soyo Town, Aso-gun, Kumamoto Prefecture. The annual average wind speed is 5.9m/s and 5.6m/s at 20m and 10m above ground, respectively, satisfying the reference values of 5.6m/s and 5.0m/s. The prevalent wind direction is WNW (occurrence rate: 32.8%). The wind from the directions with WNW at their middle occupies 75%, stable and satisfying the reference value of 60%. Strong winds come frequently from the direction of high occurrence, which is advantageous in arranging plural wind turbine systems. The exponential index in the wind speed vertical distribution is 13.3, but wind distribution is not simple at a mountain top site like the observation station in this report. Wind characteristics are similar to those at places with mild inundations, and the maximum instantaneous wind speed of 40.8m/s will not pose a problem. The wind energy density is 205W/m{sup 2}, satisfying the reference value of 150. Wind power systems of 150kW, 300kW, and 750kW are assumed. When the exponential index is 13.3, their annual operation rates will be 70%, 71%, and 82%; and their capacity ratios are 22.6%, 23.9%, and 22.9%, all satisfying the reference values. They will collect 297MWh, 629MWh, and 1507MWh of wind energy per year. It is concluded that Soyo Town is fully qualified as a site for wind power development. (NEDO)

  13. 100-kW hingeless metal wind turbine blade design, analysis and fabrication

    Science.gov (United States)

    Donham, R. E.; Schmidt, J.; Linscott, B. S.

    1975-01-01

    The design, fabrication and analysis of aluminum wind turbine rotor blades is discussed. The blades are designed to meet criteria established for a 100-kilowatt wind turbine generator operating between 8 and 60-mile-per-hour speeds at 40 revolutions per minute. The design wind speed is 18 miles per hour. Two rotor blades are used on a new facility which includes a hingeless hub and its shaft, gearbox, generator and tower. Experience shows that, for stopped rotors, safe wind speeds are strongly dependent on blade torsional and bending rigidities which the basic D spar structural blade design provides. The 0.25-inch-thick nose skin is brake/bump formed to provide the basic 'D' spar structure for the tapered, twisted blades. Adequate margins for flutter and divergence are predicted from the use of existing, correlated stopped rotor and helicopter rotor analysis programs.

  14. Modelling and Design of a 3 kW Permanent Magnet Synchronous Generator suitable for Variable Speed Small Wind Turbines

    Directory of Open Access Journals (Sweden)

    Acharya Parash

    2016-01-01

    Full Text Available This paper presents the modeling and design of a 3 kW Permanent Magnet Synchronous Generator (PMSG used for a variable speed wind turbine. Initially, the PMSG is modeled in the d-q reference frame. Different optimized parameters of the generator are extracted from the design and used in simulation of the PMSG. The generator output power is matched with the power of the turbine such that the generator is not either over-sized or under-sized.

  15. Wind power development field test project at Ebetsu plant of Oji Paper Co., Ltd. Close survey on wind conditions; Oji seishi Ebetsu kojo ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A survey was made on wind conditions at the Ebetsu plant of Oji Paper Co., Ltd., on the assumption that a demonstrative equipment of a wind power generation system was installed in the plant. The survey period was one year from Oct., 1998 to Sept., 1999. The observations were carried out on the average wind velocity, average wind direction, standard deviation of velocity, and the maximum instantaneous wind velocity. With a fixed point observation at 20 m above ground, and with the minimum observation time unit of 10 minutes, an average value during the 10 minutes was determined as the measurement of each category. However, the maximum instantaneous wind velocity was determined on the measurement with the minimum observation time unit of 2 seconds. The average wind velocity was 3.2 m/s, the maximum wind velocity during the period was 34 m/s, and the prevailing wind direction was SSE (25.6%), while the total occurrence probability on the wind axis with NW-SE as the main axis was 62.9%. The intensity of turbulence was 0.28 at a wind velocity of 2.0 m/s or above and was 0.25 at 4.0 m/s or above. An estimated annual operation rate of a windmill was 37-59% using the rated value of a 150 kW, 300 kW and 750 kW class windmills. (NEDO)

  16. Field test report of the Department of Energy's 100-kW vertical axis wind turbine

    Science.gov (United States)

    Nellums, R. O.

    1985-02-01

    Three second generation Darrieus type vertical axis wind turbines of approximately 120 kW capacity per unit were installed in 1980-1981. Through March 1984, over 9000 hours of operation had been accumulated, including 6600 hours of operation on the unit installed in Bushland, Texas. The turbines were heavily instrumented and have yielded a large amount of test data. Test results of this program, including aerodynamic, structural, drive train, and economic data are presented. Among the most favorable results were an aerodynamic peak performance coefficient of 0.41; fundamental structural integrity requiring few repairs and no major component replacements as of March 1984; and an average prototype fabrication cost of approximately $970 per peak kilowatt of output. A review of potential design improvements is presented.

  17. Electrification of the Prudencio community through a hybrid system wind photovoltaic

    International Nuclear Information System (INIS)

    Hernandez Egurrola, Dayerling Lisbet

    2011-01-01

    Paraguana Peninsula is located in the northernmost part of Venezuela, have average wind speeds above 7 m / s and solar radiation is between 5 to 6 kW -h/m2-dia without significant variation in the annual cycle. Taking into account the favorable conditions for the realization of this potential solar wind and pose the goal of designing a hybrid generation system (solar PV - wind) that supplies electricity to the coastal community of Prudencio made up of 26 families engaged mainly in fishing and not have the power supply by conventional means by be located far from the grid of the national grid. Project development began with a study that among other things includes: geographic location, topography, climate, social and economical. Subsequently determines the demand for housing and community in general to determine the requirements of the load. Finally sized autonomous electrical network formed by 2 2.0 kW wind turbines and a photovoltaic system consists of 18 panels 205 W, which supply electricity to 110 VAC single phase by using 2 inverters 4.0 kW interconnected to a whole battery bank dimensioning system according to the requirements of the load. (full text)

  18. 10 kW Contactless Power Transfer System for Rapid Charger of Electric Vehicle

    OpenAIRE

    Yamanaka, Tomohiro; Kaneko, Yasuyoshi; Abe, Shigeru; Yasuda, Tomio

    2012-01-01

    A contactless power transfer system for charging electric vehicles requires a high efficiency, a large air gap, and a good tolerance to lateral misalignment and needs to be compact and lightweight. A double-sided winding 10 kW transformer based on a 1.5 kW H-shaped core transformer was developed for a rapid charger. Even though the transformer capacity was increased, the dimensions of the 10 kW transformer were almost the same as those of the 1.5 kW transformer. In this paper, the design conc...

  19. International cooperation on wind energy for rural areas in China

    International Nuclear Information System (INIS)

    Pengfei, Shi

    1991-01-01

    An overview of the recent wind energy activities in China is given. China has a long history in harnessing the wind; modern development started during the late seventies. The Chinese wind potential is mainly in the coastal regions (North East and South East) and in Inner Mongolia. The actual total installed wind power is estimated to be 15 MW. For low lift (within 2 meters), high volume applications, e.g. salt making in salt pans along the coast, of mechanical windmills coupled to screw pumps have been developed. In Inner Mongolia, small portable wind generators (50-200 MW) charging car batteries are supplying some 100,000 farmer and herdsman families with electricity for television and lighting. The average energy consumption is between 200 and 300 kWh per year and the corresponding kWh price 0.40 to 0.50 US$. Since 1988 the demand for small wind generators declined due to the lower wool prices on the world market, affecting the income of the herdsman, and due to the fact that the machines have to be marketed in remote, less accesible rural areas. Various demonstration projects have been set up, f.e. a decentralized energy system on Dachen Island, including a wind diesel hybrid system. On Kongdon Island a 60 kW wind turbine and a 60 kW diesel generator were installed. With several foreign wind turbine manufacturers cooperations have been set up for licensed production in China. Also wind farms have been installed. The largest Chinese prototype at the moment is a 32 meter diameter, 200 kW machine. Western organizations or manufacturers are involved in most of the cooperatives. For the next five years the focus is on development of a large 150 and 200 kW machine and a windmill coupled to a centrifugal pump for lifting heads between 2 and 5 meter. 1 fig., 3 refs

  20. Location of aerodynamic noise sources from a 200 kW vertical-axis wind turbine

    Science.gov (United States)

    Ottermo, Fredric; Möllerström, Erik; Nordborg, Anders; Hylander, Jonny; Bernhoff, Hans

    2017-07-01

    Noise levels emitted from a 200 kW H-rotor vertical-axis wind turbine have been measured using a microphone array at four different positions, each at a hub-height distance from the tower. The microphone array, comprising 48 microphones in a spiral pattern, allows for directional mapping of the noise sources in the range of 500 Hz to 4 kHz. The produced images indicate that most of the noise is generated in a narrow azimuth-angle range, compatible with the location where increased turbulence is known to be present in the flow, as a result of the previous passage of a blade and its support arms. It is also shown that a semi-empirical model for inflow-turbulence noise seems to produce noise levels of the correct order of magnitude, based on the amount of turbulence that could be expected from power extraction considerations.

  1. Wind power development field test project at Hirashima, Sakito-cho. Detailed wind characteristics survey; Sakitocho Hirashima ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A detailed wind characteristics survey was conducted at Hirashima, Sakito-cho, Nishisonogi-gun, Nagasaki Prefecture, on the assumption that a wind power generation system would be constructed. The survey was a 1-year project from October 1998 through September 1999, and wind characteristics such as the average wind speed, average wind direction, standard deviation of wind velocity, and the maximum instantaneous wind speed were observed. The observation point was fixed at 20m above ground, the minimum time unit for observation was 10 minutes, and the 10-minute average value was defined as the measured value. For the maximum instantaneous wind speed, the minimum time unit for observation was set to be 2 seconds. The yearly average wind speed was 7.1m/s and the maximum wind speed in the period was 37m/s. Winds came prevalently from N (13.9%), and then from NNE (13.3%), NW (12.2%), and NE (10.7%). The total wind direction occurrence rate involving the 4 directions was 50.1%. Turbulence intensity was 0.14 at wind speed 2.0m/s or more and 0.12 at wind speed 4.0m/s or more. Estimated wind turbine yearly operating factors of 77-87% were obtained using rated values of a 150kW, 300kW, and 750kW-class wind turbines. (NEDO)

  2. Turbulence influence on optimum tip speed ratio for a 200 kW vertical axis wind turbine

    Science.gov (United States)

    Möllerström, E.; Eriksson, S.; Goude, A.; Ottermo, F.; Hylander, J.

    2016-09-01

    The influence of turbulence intensity (TI) on the tip speed ratio for maximum power coefficient, here called λCp_max, is studied for a 200 kW VAWT H-rotor using logged data from a 14 month period with the H-rotor operating in wind speeds up to 9 m/s. The TI - λCp_max relation is examined by dividing 10 min mean values in different turbulence intensity ranges and producing multiple CP(λ) curves. A clear positive relation between TI and λCp_max is shown and is further strengthened as possible secondary effects are examined and deemed non-essential. The established relation makes it possible to tune the control strategy to enhance the total efficiency of the turbine.

  3. Wind power development field test project at Ashibe-cho. Detailed wind characteristics survey; Ashibecho ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A detailed wind characteristics survey was conducted at Ashibe-cho, Iki-gun, Nagasaki Prefecture, on the assumption that a wind power generation system would be constructed. The survey was a 1-year project from October 1998 through September 1999, and wind characteristics such as the average wind speed, average wind direction, standard deviation of wind velocity, and the maximum instantaneous wind speed were observed. The observation point was fixed at 20m above ground, the minimum time unit for observation was 10 minutes, and the 10-minute average value was defined as the measured value. For the maximum instantaneous wind speed, the minimum time unit for observation was set to be 2 seconds. The yearly average wind speed was 5.8m/s and the maximum wind speed in the period was 35m/s. Winds came from the prevailing direction of NE (21.3%), and then from NNE (14.7%) and ENE (7.9%). The wind axis was in the NE-SW direction, and the total wind direction occurrence rate from the 6 directions was 60.2%. Turbulence intensity was 0.19 at wind speed 2.0m/s or more and 0.17 at wind speed 4.0m/s or more. Estimated wind turbine yearly operating factors of 66-84% were obtained using rated values of a 150kW, 300kW, and 750kW-class wind turbines. (NEDO)

  4. Canadian small wind market

    International Nuclear Information System (INIS)

    Moorhouse, E.

    2010-01-01

    This PowerPoint presentation discussed initiatives and strategies adopted by the Canadian Wind Energy Association (CanWEA) to support the development of Canada's small wind market. The general public has shown a significant interest in small wind projects of 300 kW. Studies have demonstrated that familiarity and comfort with small wind projects can help to ensure the successful implementation of larger wind projects. Small wind markets include residential, farming and commercial, and remote community applications. The results of CanWEA market survey show that the small wind market grew by 78 percent in 2008 over 2007, and again in 2009 by 32 percent over 2008. The average turbine size is 1 kW. A total of 11,000 turbines were purchased in 2007 and 2008. Global small wind market growth increased by 110 percent in 2008, and the average turbine size was 2.4 kW. Eighty-seven percent of the turbines made by Canadian mid-size wind turbine manufacturers are exported, and there is now a significant risk that Canada will lose its competitive advantage in small wind manufacturing as financial incentives have not been implemented. American and Canadian-based small wind manufacturers were listed, and small wind policies were reviewed. The presentation concluded with a set of recommendations for future incentives, educational programs and legislation. tabs., figs.

  5. Decentralized/stand-alone hybrid Wind-Diesel power systems to meet residential loads of hot coastal regions

    International Nuclear Information System (INIS)

    Elhadidy, M.A.; Shaahid, S.M.

    2005-01-01

    In view of rising costs, pollution and fears of exhaustion of oil and coal, governments around the world are encouraging to seek energy from renewable/sustainable energy sources such as wind. The utilization of energy from wind (since the oil embargo of the 1970s) is being widely disseminated for displacement of fossil fuel produced energy and to reduce atmospheric degradation. A system that consists of a wind turbine and Diesel genset is called a Wind-Diesel power system.The literature indicates that the commercial/residential buildings in Saudi Arabia consume an estimated 10-40% of the total electric energy generated. In the present study, the hourly mean wind-speed data of the period 1986-1997 recorded at the solar radiation and meteorological station, Dhahran (26 deg. 32'N, 50 deg. 13'E in the Eastern Coastal Region of Saudi Arabia), has been analyzed to investigate the potential of utilizing hybrid (Wind-Diesel) energy conversion systems to meet the load requirements of a hundred typical two bedroom residential buildings (with annual electrical energy demand of 3512 MWh). The long term monthly average wind speeds for Dhahran range from 4.2 to 6.4 m/s. The hybrid systems considered in the present case study consist of different combinations/clusters of 150 kW commercial wind machines supplemented with battery storage and Diesel back-up. The deficit energy generated by the Diesel generator (for different battery capacities) and the number of operational hours of the Diesel system to meet a specific annual electrical energy demand of 3512 MWh have also been presented. The evaluation of the hybrid system shows that with seven 150 kW wind energy conversion system (WECS) and one day of battery storage, the Diesel back-up system has to provide 21.6% of the load demand. Furthermore, with three days of battery storage, the Diesel back-up system has to provide 17.5% of the load demand. However, in the absence of battery storage, about 37% of the load needs to be

  6. Report on the field test project for wind power development at Yugawara Town (wind characteristics investigation); Yugawaramachi ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Wind characteristics are observed in the period November 1997 through October 1998 at Yugawara Town, Kanagawa Prefecture. The average wind speed is 5.1m/s and 5.0m/s at 20m and 10m above ground, respectively, suggesting that the difference in altitude causes but a very small difference in wind speed and that a large wind speed component exists in the vertical direction. Under the 16 compass point system, the wind direction occurrence rate is the highest in the NE direction and the second highest in the W direction. The two directions are prevalent, and their occurrence rates on the wind axes total 62.6%. The occurrence rate of wind speeds of not less than 5m/s is 40%. Turbulence intensity is 0.23 and 0.17 for the average wind speed of not less than 2m/s and for the average wind speed of not less than 4m/s, respectively, suggesting but a little impact of air current turbulence. The amounts of energy to be acquired by wind turbine systems of 150kW, 300kW, and 750kW are estimated at 301,363kWh, 651,593kWh, and 1,668,825kWh, respectively. Their annual capacity ratios are 22.9%, 24.8%, and 25.4%, respectively. Since difference in wind speed due to difference in altitude is small, it is supposed that the wind speed at the hub altitude is not so high. It is inferred consequently that service operation will be quite difficult to realize. Difficulties will be also encountered in relation to the route of turbine system transportation, power distribution line, and the distance to a transformation station. (NEDO)

  7. Development of Offshore Wind Power Industry

    Institute of Scientific and Technical Information of China (English)

    Liu Xiao

    2011-01-01

    The offshore wind power development target as initially proposed in "The 12=Five-Year" on energy recourses development and renewable energy recourses currently under development is to reach 5m KW by 2015 and 30m KW by 2020. With the unfolding of offshore wind turbine planning from different areas, the curtain of offshore wind power development for our country's "The 12=Five-Year" has been opened.

  8. Should we build wind farms close to load or invest in transmission to access better wind resources in remote areas? A case study in the MISO region

    International Nuclear Information System (INIS)

    Lamy, Julian V.; Jaramillo, Paulina; Azevedo, Inês L.; Wiser, Ryan

    2016-01-01

    Wind speeds in remote areas are sometimes very high, but transmission costs to access these locations can be prohibitive. We present a conceptual model to estimate the economics of accessing high quality wind resources in remote areas to comply with renewable energy policy targets, and apply the model to the Midwestern grid (MISO) as a case study. We assess the goal of providing 40 TWh of new wind generation while minimizing costs, and include temporal aspects of wind power (variability costs and correlation to market prices) as well as total wind power produced from different farms. We find that building wind farms in North/South Dakota (windiest states) compared to Illinois (less windy, but close to load) would only be economical if the incremental transmission costs to access them were below $360/kW of wind capacity (break-even value). Historically, the incremental transmission costs for wind development in North/South Dakota compared to in Illinois are about twice this value. However, the break-even incremental transmission cost for wind farms in Minnesota/Iowa (also windy states) is $250/kW, which is consistent with historical costs. We conclude that wind development in Minnesota/Iowa is likely more economical to meet MISO renewable targets compared to North/South Dakota or Illinois. - Highlights: •We evaluate the economics of building wind farms in remote areas in MISO. •We present a conceptual wind site selection model to meet 40 TWh of new wind. •We use the model to compare remote windy sites to less windy ones closer to load. •We show break-even transmission costs that would justify remote wind development. •Comparing break-even values to historical costs, MN/IA sites are most economical.

  9. 2012 Market Report on U.S. Wind Technologies in Distributed Applications

    Energy Technology Data Exchange (ETDEWEB)

    Orrell, Alice C.; Flowers, L. T.; Gagne, M. N.; Pro, B. H.; Rhoads-Weaver, H. E.; Jenkins, J. O.; Sahl, K. M.; Baranowski, R. E.

    2013-08-06

    At the end of 2012, U.S. wind turbines in distributed applications reached a 10-year cumulative installed capacity of more than 812 MW from more than 69,000 units across all 50 states. In 2012 alone, nearly 3,800 wind turbines totaling 175 MW of distributed wind capacity were documented in 40 states and in the U.S. Virgin Islands, with 138 MW using utility-scale turbines (i.e., greater than 1 MW in size), 19 MW using mid-size turbines (i.e., 101 kW to 1 MW in size), and 18.4 MW using small turbines (i.e., up to 100 kW in size). Distributed wind is defined in terms of technology application based on a wind project’s location relative to end-use and power-distribution infrastructure, rather than on technology size or project size. Distributed wind systems are either connected on the customer side of the meter (to meet the onsite load) or directly to distribution or micro grids (to support grid operations or offset large loads nearby). Estimated capacity-weighted average costs for 2012 U.S. distributed wind installations was $2,540/kW for utility-scale wind turbines, $2,810/kW for mid-sized wind turbines, and $6,960/kW for newly manufactured (domestic and imported) small wind turbines. An emerging trend observed in 2012 was an increased use of refurbished turbines. The estimated capacity-weighted average cost of refurbished small wind turbines installed in 2012 was $4,080/kW. As a result of multiple projects using utility-scale turbines, Iowa deployed the most new overall distributed wind capacity, 37 MW, in 2012. Nevada deployed the most small wind capacity in 2012, with nearly 8 MW of small wind turbines installed in distributed applications. In the case of mid-size turbines, Ohio led all states in 2012 with 4.9 MW installed in distributed applications. State and federal policies and incentives continued to play a substantial role in the development of distributed wind projects. In 2012, U.S. Treasury Section 1603 payments and grants and loans from the U

  10. Wind power development field test project at Aoyama Heights, Aoyama-cho. Detailed wind characteristics survey; Aoyamacho Aoyama Kogen ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A detailed wind characteristics survey was conducted at Aoyama Heights, Aoyama-cho, Naga-gun, Mie Prefecture, on the assumption that a wind power generation system would be constructed. The survey was a 1-year project from October 1998 through September 1999, and wind characteristics such as the average wind speed, average wind direction, standard deviation of wind velocity, and the maximum instantaneous wind speed were observed. The observation point was fixed at 20m above ground, the minimum time unit for observation was 10 minutes, and the 10-minute average value was defined as the measured value. For the maximum instantaneous wind speed, the minimum time unit for observation was set to be 2 seconds. The yearly average wind speed was 5.3m/s and the maximum wind speed in the period was 32m/s. Winds came prevalently from WNW (31.6%), and then from NW (16.8%), ESE (20.9%), and E (9.9%). The wind axis was in the direction of WNW-ESE, and the total wind direction occurrence rate was 89.0%. Turbulence intensity was 0.25 at wind speed 2.0m/s or more and 0.23 at wind speed 4.0m/s or more. Estimated wind turbine yearly operating factors of 70-84% were obtained using rated values of a 150kW, 300kW, and 750kW-class wind turbines. (NEDO)

  11. Wind energy developments in the 20th century

    Science.gov (United States)

    Vargo, D. J.

    1974-01-01

    Wind turbine systems for generating electrical power have been tested in many countries. Representative examples of turbines which have produced from 100 to 1250 kW are described. The advantages of wind energy consist of its being a nondepleting, nonpolluting, and free fuel source. Its disadvantages relate to the variability of wind and the high installation cost per kilowatt of capacity of wind turbines when compared to other methods of electric-power generation. High fuel costs and potential resource scarcity have led to a five-year joint NASA-NSF program to study wind energy. The program will study wind energy conversion and storage systems with respect to cost effectiveness, and will attempt to estimate national wind-energy potential and develop techniques for generator site selection. The studies concern a small-systems (50-250 kW) project, a megawatt-systems (500-3000 kW) project, supporting research and technology, and energy storage. Preliminary economic analyses indicate that wind-energy conversion can be competitive in high-average-wind areas.

  12. 40 CFR 265.251 - Protection from wind.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Protection from wind. 265.251 Section... FACILITIES Waste Piles § 265.251 Protection from wind. The owner or operator of a pile containing hazardous waste which could be subject to dispersal by wind must cover or otherwise manage the pile so that wind...

  13. Wind Turbine Test. Wind Matic WM 17S

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    The report describes standard measurements performed on a Wind-Matic WM 17S, 75 kW wind turbine. The measurements carried out and reported here comprises the power output, system efficiency, energy production, transmission efficiency, rotor power, rotor efficiency, air-brakes efficiency, structural...

  14. Wind Turbine Test Wind Matic WM 15S

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    The report describes standard measurements performed on a Wind-Matic WM 15S, 55 kW wind turbine. The measurements carried out and reported here comprises the power output, system efficiency, energy production, transmission efficiency, rotor power, rotor efficiency, air-brakes efficiency, dynamical...

  15. Preliminary design and economic investigations of Diffuser-Augmented Wind Turbines (DAWT)

    Energy Technology Data Exchange (ETDEWEB)

    Foreman, K.M.

    1981-12-01

    A preferred design and configuration approach is suggested for the DAWT innovative wind energy conversion system. A preliminary economic asessment is made for limited production rates of units between 5 and 150 kw rated output. Nine point designs are used to arrive at the conclusions regarding best construction material for the diffuser and busbar cost of electricity (COE). It is estimated that for farm and REA cooperative end users, the COE can range between 2 and 3.5 cents/kWh for sites with annual average wind speeds of 16 and 12 mph (25.7 and 19.3 km/h) respectively, and 150 kW rated units. No tax credits are included in these COE figures. For commercial end users of these 150 kW units the COE ranges between 4.0 and 6.5 cents/kWh for 16 and 12 mph sites. These estimates in 1979 dollars are lower than DOE goals set in 1978 for the rating size and end applications. Recommendations are made for future activities to maintain steady, systematic progress toward mature development of the DAWT.

  16. Remote power supply by wind/diesel/battery systems - operational experience and economy

    International Nuclear Information System (INIS)

    Kniehl, R.; Cramer, G.; Toenges, K.H.

    1995-01-01

    To continuously supply remote villages and settlements not connected to the public grid with electric power is an ambitious technical task considering ecological and economical points of view. The German company SMA has developed a modular supply system as a solution for this task in the range of 30 kW to 5 MW. Meanwhile more than 20 applications of these 'Intelligent Power Systems (IPS)' have proved their technical reliability and economical competitiveness worldwide under different, and also extreme environmental conditions. Actually it is the first commercially available advanced Wind/Diesel/Battery System for remote area electrification. The modular autonomous electric supply systems realized by SMA basically consist of two or more diesel power sets, battery storage with converter, a rotating phaseshifter, and an optional number of wind turbines. All modules are coupled on the 3-phase AC system grid and run in various parallel configurations depending on the wind speed and the consumer power demand. The control system operates fully automatical and offers a very user-friendly graphical interface. This advanced system control also contains a remote control and operating data output via modem and telephone line. SMA and CES have considerable experience with Wind/Diesel/Battery Systems for more than eight years. In many cases wind energy converters in the power range of 30 to 40 kW were used, but it is also possible to use larger wind turbines (e.g. 250 kW). In the following the system technology is described in detail, experience of different system sizes in several countries of application is presented, and economical analyses for power supply by IPS are given in comparison to a conventional fully diesel power supply. (author)

  17. Remote power supply by wind/diesel/battery systems - operational experience and economy

    Energy Technology Data Exchange (ETDEWEB)

    Kniehl, R [CES - Consulting and Engineering Services, Heidelberg (Germany); Cramer, G; Toenges, K H [SMA Regelsysteme GmbH, Niestetal (Germany)

    1996-12-31

    To continuously supply remote villages and settlements not connected to the public grid with electric power is an ambitious technical task considering ecological and economical points of view. The German company SMA has developed a modular supply system as a solution for this task in the range of 30 kW to 5 MW. Meanwhile more than 20 applications of these `Intelligent Power Systems (IPS)` have proved their technical reliability and economical competitiveness worldwide under different, and also extreme environmental conditions. Actually it is the first commercially available advanced Wind/Diesel/Battery System for remote area electrification. The modular autonomous electric supply systems realized by SMA basically consist of two or more diesel power sets, battery storage with converter, a rotating phaseshifter, and an optional number of wind turbines. All modules are coupled on the 3-phase AC system grid and run in various parallel configurations depending on the wind speed and the consumer power demand. The control system operates fully automatical and offers a very user-friendly graphical interface. This advanced system control also contains a remote control and operating data output via modem and telephone line. SMA and CES have considerable experience with Wind/Diesel/Battery Systems for more than eight years. In many cases wind energy converters in the power range of 30 to 40 kW were used, but it is also possible to use larger wind turbines (e.g. 250 kW). In the following the system technology is described in detail, experience of different system sizes in several countries of application is presented, and economical analyses for power supply by IPS are given in comparison to a conventional fully diesel power supply. (author)

  18. Remote power supply by wind/diesel/battery systems - operational experience and economy

    Energy Technology Data Exchange (ETDEWEB)

    Kniehl, R. [CES - Consulting and Engineering Services, Heidelberg (Germany); Cramer, G.; Toenges, K.H. [SMA Regelsysteme GmbH, Niestetal (Germany)

    1995-12-31

    To continuously supply remote villages and settlements not connected to the public grid with electric power is an ambitious technical task considering ecological and economical points of view. The German company SMA has developed a modular supply system as a solution for this task in the range of 30 kW to 5 MW. Meanwhile more than 20 applications of these `Intelligent Power Systems (IPS)` have proved their technical reliability and economical competitiveness worldwide under different, and also extreme environmental conditions. Actually it is the first commercially available advanced Wind/Diesel/Battery System for remote area electrification. The modular autonomous electric supply systems realized by SMA basically consist of two or more diesel power sets, battery storage with converter, a rotating phaseshifter, and an optional number of wind turbines. All modules are coupled on the 3-phase AC system grid and run in various parallel configurations depending on the wind speed and the consumer power demand. The control system operates fully automatical and offers a very user-friendly graphical interface. This advanced system control also contains a remote control and operating data output via modem and telephone line. SMA and CES have considerable experience with Wind/Diesel/Battery Systems for more than eight years. In many cases wind energy converters in the power range of 30 to 40 kW were used, but it is also possible to use larger wind turbines (e.g. 250 kW). In the following the system technology is described in detail, experience of different system sizes in several countries of application is presented, and economical analyses for power supply by IPS are given in comparison to a conventional fully diesel power supply. (author)

  19. Analysis of cost estimation and wind energy evaluation using wind energy conversion systems (WECS) for electricity generation in six selected high altitude locations in Nigeria

    International Nuclear Information System (INIS)

    Ohunakin, S. Olayinka; Ojolo, S. Joshua; Ogunsina, S. Babatunde; Dinrifo, R. Rufus

    2012-01-01

    Two commercial wind turbines namely AN Bonus 300 kW/33 and AN Bonus 1 MW/54 were technically assessed for electricity generation in six selected high altitude sites spreading across the North-West and North-East geopolitical regions of Nigeria by computing their capacity factors, annual power and energy outputs. The economic evaluation of using the two wind energy conversion systems (medium and large) for electric power generation in the selected locations were also estimated using the present value cost method. The results showed that capacity factors of the two turbines in the selected sites ranged between 4.6 and 43%. Average minimum cost per kW h was obtained in Kano as $0.0222/kW h with AN Bonus 1 MW while the highest average cost is $0.2074/kW h with AN Bonus 300 kW in Kaduna. The highest cost in each of the location was obtained with the medium WECs (AN Bonus 300 kW). In addition, Kano and Katsina were also found to be very economical for any of the adopted wind turbine models. Gusau and Kaduna, at cost of unit energy of about $0.30/kW h were found to be more profitable for non-connected electrical and mechanical applications (water pumping, battery charging) than diesel generator. - Highlights: ► All the locations considered have mean wind speeds above 4.8 m/s. ► Economical wind applications are possible in Kano and Katsina. ► Highest capacity factor and energy output are obtained using AN Bonus 1 MW in Kano. ► Specific cost of unit energy per kW h is cheaper using AN Bonus 1 MW.

  20. S-band low noise amplifier and 40 kW high power amplifier subsystems of Japanese Deep Space Earth Station

    Science.gov (United States)

    Honma, K.; Handa, K.; Akinaga, W.; Doi, M.; Matsuzaki, O.

    This paper describes the design and the performance of the S-band low noise amplifier and the S-band high power amplifier that have been developed for the Usuda Deep Space Station of the Institute of Space and Astronautical Science (ISAS), Japan. The S-band low noise amplifier consists of a helium gas-cooled parametric amplifier followed by three-stage FET amplifiers and has a noise temperature of 8 K. The high power amplifier is composed of two 28 kW klystrons, capable of transmitting 40 kW continuously when two klystrons are combined. Both subsystems are operating quite satisfactorily in the tracking of Sakigake and Suisei, the Japanese interplanetary probes for Halley's comet exploration, launched by ISAS in 1985.

  1. The current wind energy programme in Italy

    International Nuclear Information System (INIS)

    Ambrosini, G.; Foli, U.; Sesto, E.; Vigotti, R.

    1991-01-01

    In Italy, the main activities in the field of wind energy are carried out by two state-owned organizations, ENEA (Italian National Agency for New Technologies, Energy and the Environment) and ENEL (Italian National Electricity Board), and two major wind turbine generator manufacturers, Alenia/WEST and Riva Calzoni, within the framework of a national programme which is supervized by the Ministry of Industry and Commerce. The work currently under way concerns both wind power plant siting and the development and testing of Italian-made wind turbine generators ranging from 5 to 1500 kW in power. In addition, programmes aimed at constructing wind-farms made up of medium-sized machines (200-400 kW) have recently been launched

  2. Wind power in Denmark technology, policies and results

    International Nuclear Information System (INIS)

    Dannemand Andersen, Per

    1998-11-01

    The Association of Danish Electricity Utilities has estimated the total electricity production from wind turbines in 1997 as 1932 GWh: 384 GWh from utility-owned turbines and 1548 GWh from privately owned turbines. This equals 6% of total electricity consumption in Denmark. Corrected to a 'normal wind year' this equals 6.6% of Denmark's annual electricity consumption. The wind energy index in 1997 was 91%. According to the Danish Association of Electricity Utilities, 4784 turbines with a capacity of 1129 MW were connected to the grid at the end of 1997. 534 turbines and 287 MW were added in 1997, the largest figure ever. These are net figures and included dismantled machines. The actual sales of turbines is a bit higher, reflecting the fact that not all machines sold in 1997 were installed that year. New machines are usually 500 kW, 600 kW and 750 kW. No 1500 kW machines have as yet been installed on a commercial basis in Denmark. (au)

  3. Gearless wind power generator

    Energy Technology Data Exchange (ETDEWEB)

    Soederlund, L.; Ridanpaeae, P.; Vihriaelae, H.; Peraelae, R. [Tampere Univ. of Technology (Finland). Lab. of Electricity and Magnetism

    1998-12-31

    During the wind power generator project a design algorithm for a gearless permanent magnet generator with an axially orientated magnetic flux was developed and a 10 kW model machine was constructed. Utilising the test results a variable wind speed system of 100 kW was designed that incorporates a permanent magnet generator, a frequency converter and a fuzzy controller. This system produces about 5-15% more energy than existing types and stresses to the blades are minimised. The type of generator designed in the project represents in general a gearless solution for slow-speed electrical drives. (orig.)

  4. 6kW class laser cutting equipment; 6kW daishutsuryoku laser setsudanki ni yoru atsuita setsudan

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Y.; Nagahori, M. [Tanaka Engineering Works Ltd., Saitama (Japan)

    1994-11-01

    Application of the laser cutting machine to the area of cutting steel plates of 5 mm thick or more was first enabled in 1990 by the 2 kW oscillator that was introduced in that year. The thick plate cutting industry has a short history. This paper describes the features and performance of the 6 kW laser cutting machine that was announced in April, 1994. The machine uses a newly developed high-speed axial flow type carbon dioxide laser oscillater with the rated output of 6 kW. As the discharge excitation method, the machine adopted the RF (radio frequency) method that causes low contamination in the discharge tube. The 6 kW laser cutting machine has a number of features such as a large cutting area provided by the oscillator contained in the cutting machine, cutting quality stabilized by the optical path length fixing unit, and automatic functions such as automatic setting of the cutting conditions and scheduled operation. The machine can cut mild steel plates of up to 40 mm thick (or up to 16 mm for stainless steel plates) at the cutting speed of 1600 mm/min for a 16 mm thick plate and 2200 mm/min for a 12 mm thick plate, with the good cut sectional surface. 5 figs., 1 tab.

  5. The Danish large wind turbine program. [feasibility of wind power in a utility grid

    Science.gov (United States)

    Pederson, B. M.

    1979-01-01

    A brief description of the Danish wind energy program and its present status is given. Results and experiences from tests on the Gedser windmill (200 kW) are presented. The key results are presented from the preliminary design study and detailed design of two new WECS (630 kW each) is described.

  6. The wind power of Mexico

    International Nuclear Information System (INIS)

    Hernandez-Escobedo, Q.; Manzano-Agugliaro, F.; Zapata-Sierra, A.

    2010-01-01

    The high price of fossil fuels and the environmental damage they cause have encouraged the development of renewable energy resources, especially wind power. This work discusses the potential of wind power in Mexico, using data collected every 10 min between 2000 and 2008 at 133 automatic weather stations around the country. The wind speed, the number of hours of wind useful for generating electricity and the potential electrical power that could be generated were estimated for each year via the modelling of a wind turbine employing a logistic curve. A linear correlation of 90.3% was seen between the mean annual wind speed and the mean annual number of hours of useful wind. Maps were constructed of the country showing mean annual wind speeds, useful hours of wind, and the electrical power that could be generated. The results show that Mexico has great wind power potential with practically the entire country enjoying more than 1700 h of useful wind per year and the potential to generate over 2000 kW of electrical power per year per wind turbine installed (except for the Chiapas's State). Indeed, with the exception of six states, over 5000 kW per year could be generated by each turbine. (author)

  7. Investigation of wind power potential at Oran, northwest of Algeria

    International Nuclear Information System (INIS)

    Boudia, Sidi Mohammed; Guerri, Ouahiba

    2015-01-01

    Highlights: • Wind resource assessment in the northwestern part of Algeria using WAsP Software. • Comparison between the performances of 6 WECs at 3 sites with great potential. • Assessment of the wind power cost per kW h of electricity produced. • Stall-regulated wind turbines are more appropriated for Site 1. • Pitch-regulated wind turbines are suggested for the windiest Site. - Abstract: In this work, ten years of wind data from Oran meteorological station have been used to evaluate the potential of wind power on the Oranie region, in the North-western part of Algeria, open on the Mediterranean Sea. The WAsP program was used to analyze the wind Atlas of the region to find the windiest areas. Three regions were chosen for their great wind potential. The study proposes to assess wind power cost per kW h of electricity produced using six types of WECs. The investigation at 10 m above ground at the location of the meteorological station shows that Oran has an average wind potential, with an annual mean wind speed equal to 4.2 m/s and an annual mean power density of 129 W/m 2 . The temporal study shows that spring period is the windiest with 4.9 m/s. In terms of energy production, the results show that the second site is the best location for harnessing the wind power to generate electricity. The minimum cost per kW h of electricity generated in that location is about 0.0181$/kW h with a capacity factor equal to 51.36% for an annual energy production equal to 11.14 GW h, given by the Power Wind 90 wind turbine of 2.5 MW power rated capacity.

  8. Canadian Wind Energy Association small wind conference proceedings : small wind policy developments (turbines of 300 kW or less)

    International Nuclear Information System (INIS)

    2005-01-01

    The small wind session at the Canadian Wind Energy Association's (CanWEA) annual conference addressed policies affecting small wind, such as net metering, advanced renewable tariffs and interconnections. It also addressed CanWEA's efforts in promoting small wind turbines, particularly in remote northern communities, small businesses and within the residential sector. Small wind systems are typically installed in remote communities to offset utility supplied electricity at the retail price level. In certain circumstances, small wind and hybrid systems can produce electricity at less than half the cost of traditional electricity sources, which in remote communities is typically diesel generators. Small wind turbines require different materials and technologies than large wind turbines. They also involve different local installation requirements, different by-laws, tax treatment and environmental assessments. Small wind turbines are typically installed for a range of factors, including energy independence, energy price stability and to lower environmental impacts of traditional power generation. The small wind session at the conference featured 14 presentations, of which 4 have been catalogued separately for inclusion in this database. tabs., figs

  9. Application of wind power systems to the Service Area of the Minnesota Power and Light Company. Final report, July 1975--August 1976

    Energy Technology Data Exchange (ETDEWEB)

    Lindquist, O.H.; Malver, F.S.

    1976-01-01

    Honeywell, in a joint effort with Minnesota Power and Light Company (MP and L), Boeing Vertol Company, and Dr. C.G. Justus, Georgia Institute of Technology, has conducted a regional application study of wind energy systems. Minnesota Power and Light Company, an investor-owned company with 853-MW owned capacity, has served as the case study subject utility. An initial system definition was developed based on available wind information and near-term wind turbine generator (WTG) technology. The system was tailored to fit MP and L's forecasted generation needs and the company's existing transmission and distribution system. Honeywell developed a WECS simulation to convert wind data to wind energy available for input to the utility's grid. The simulation was used to evaluate the performance of preliminary design wind turbine generators developed for ERDA/NASA by the General Electric Company and Kaman Aerospace Corporation, and to evaluate the performance of a wind turbine optimized for the Northern Minnesota wind regime and developed by the Boeing Vertol Company under subcontract to Honeywell.

  10. Wind energy development in the light of Danish experiences

    International Nuclear Information System (INIS)

    Frandsen, S.

    1991-01-01

    Wind energy will undoubtedly play a significant role in the future energy supply being a nonpolluting energy source, which on a technical basis has proved to be an economically feasible and thus a realistic alternative to traditional power production. This conclusion may be drawn from Danish experiences where energy planning comprises a visible contribution from wind energy. Since 1976 more than 3200 wind turbine units have been installed in Denmark, representing a capacity of roughly 340 MW out of a grid capacity of 8,000 MW. These units are all grid-connected and the unit sizes range from 55 kW to 450 kW. The installed wind energy capacity represents a substantial development of technologies for wind energy utilization during the last 15 years, involving participation from many sides: research institutes, electric utilities, the national energy administration, and private industry. The development has implied a considerable improvement of the technical and economic performance of wind turbines along with increased reliability and durability. The successful development has been strongly supported by comprehensive government programmes, i.e. establishment of a national wind energy research programme, establishment of the Riso Test Station for Windmills and a subsidy scheme for private turbine owners. The improved economic performance is partly the result of a development in rotor size of commercially available wind turbines. In 1981 the largest commercial wind turbine size in Denmark was 55 kW, while today it is close to 500 kW. In the same period the average energy production per installed unit capacity almost doubled, due to enhanced aerodynamic rotor design, increased tower height and improved overall design and production methods. (author) 7 figs., 3 tabs., 13 refs

  11. Wind power in Denmark technology, policies and results

    Energy Technology Data Exchange (ETDEWEB)

    Dannemand Andersen, Per [ed.] [Risoe National Lab. (Denmark)

    1998-11-01

    The Association of Danish Electricity Utilities has estimated the total electricity production from wind turbines in 1997 as 1932 GWh: 384 GWh from utility-owned turbines and 1548 GWh from privately owned turbines. This equals 6% of total electricity consumption in Denmark. Corrected to a `normal wind year` this equals 6.6% of Denmark`s annual electricity con-sumption. The wind energy index in 1997 was 91%. According to the Danish Association of Electricity Utilities, 4784 turbines with a capacity of 1129 MW were connected to the grid at the end of 1997. 534 turbines and 287 MW were added in 1997, the largest figure ever. These are net figures and included dismantled machines. The actual sales of turbines is a bit higher, reflecting the fact that not all machines sold in 1997 were installed that year. New machines are usually 500 kW, 600 kW and 750 kW. No 1500 kW machines have as yet been installed on a commercial basis in Denmark. (au)

  12. Tvindkraft: Implementing a 500 kW 21-IGBT-Based Frequency Converter for a 1.7 MW Wind Power Conversion System

    DEFF Research Database (Denmark)

    Gonzalez, Pablo Casado; Pang, Ying; Reigosa, Paula Diaz

    2013-01-01

    The 54-meter-high Tvindkraft windmill was built by a group of volunteers during 1975-1978, as an argument for renewable energy sources as well as an argument against nuclear power. At that time it was the world’s biggest windmill. So far, Tvindkraft has been running for 35 years, proving...... that a wellconstructed wind turbine is a sustainable approach to renewable energy utilization. This paper deals with the analysis, simulation, implementation and experimental testing of a new 500 kW 21- IGBT-based frequency converter that will run in parallel with the former 12-Thyristor-based frequency converter...... to fully utilize the capacity of the windmill. Simulations and experimental results are presented side-by-side to verify the proper functionalities of the frequency converter described in this paper....

  13. Feasibility study on the wind farm; Wind farm no kanosei chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For assessment of the possibility of the wind farm (collective wind power facility) in Japan, site conditions, business plans and various issues in development were arranged using some projects in a planning stage. The case study of a system design was also conducted for a typical site. Four sites were selected based on geographical conditions, topographic features and weather conditions. Scales of every site are as large as 1000-3000kW and 400- 750kW in wind turbine capacity. Every developer expects a subsidy, and governmental economic support is indispensable for the wind farm. In the case of Hisai city, Mie prefecture with the most favorable wind condition in Japan, the annual mean wind velocity of the site is valued at nearly 8m/s, suggesting that it is promising for the wind farm. From the planned scale of 750kWtimes4, the annual generated power and availability factor are valued at 9,800,000kWh/y and 37%, respectively. From the construction cost of 1 billion yen including a subsidy of its half, the generation cost is valued at 14.5 yen/kWh in durability of 15 years, and 12.2 yen/kWh in 20 years, and the profitability is dependent on the purchase price of a power company. 27 figs., 36 tabs.

  14. Efficiency assessment of a wind pumping system

    International Nuclear Information System (INIS)

    Lara, David D.; Merino, Gabriel G.; Pavez, Boris J.; Tapia, Juan A.

    2011-01-01

    The combined efficiency of the components determines overall system performance in electric wind pumping systems. We evaluated a system composed of a 3 kW wind generator feeding a battery bank of 48 V/880 Ah by means of a non-controlled 6-pulse rectifier. Connected to this battery bank was a 1.5 kW inverter that generated 220 V at 50 Hz, which powers a 1.1 kW single-phase electric pump. At the University of Concepcion, Chile, energy losses in each electrical component was determined using a data collection system configured to measure electrical variables in real time. The electrical power generated by the wind generator for different wind speeds averaged 38% lower than the power curve provided by the manufacturer. Electromechanical tests performed in a lab showed the operation efficiency of the electric generator of the wind turbine averaged 80%. This information, along with the electrical power output, and the wind velocity measured during field operation allowed us to determine the rotor's power coefficient C p , which had a maximum value of 35%. For the stored energy components measured data indicated that the rectifier, the battery bank, and the inverter operated with average efficiencies of 95%, 78% and 86% respectively. The combined component efficiencies showed a maximum of 17% of the wind energy would be available for water pumping. Since a large amount of wind energy was dissipated during the energy conversion process, new configurations should be analyzed that could avoid such losses in wind pumping systems.

  15. Efficiency assessment of a wind pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Lara, David D.; Merino, Gabriel G. [Department of Mechanization and Energy, University of Concepcion, Avenida Vicente Mendez 595, Chillan (Chile); Pavez, Boris J. [Department of Electrical Engineering, University of La Frontera, Casilla 54-D, Temuco (Chile); Tapia, Juan A. [Department of Electrical Engineering, University of Concepcion, Casilla 160-C, Concepcion (Chile)

    2011-02-15

    The combined efficiency of the components determines overall system performance in electric wind pumping systems. We evaluated a system composed of a 3 kW wind generator feeding a battery bank of 48 V/880 Ah by means of a non-controlled 6-pulse rectifier. Connected to this battery bank was a 1.5 kW inverter that generated 220 V at 50 Hz, which powers a 1.1 kW single-phase electric pump. At the University of Concepcion, Chile, energy losses in each electrical component was determined using a data collection system configured to measure electrical variables in real time. The electrical power generated by the wind generator for different wind speeds averaged 38% lower than the power curve provided by the manufacturer. Electromechanical tests performed in a lab showed the operation efficiency of the electric generator of the wind turbine averaged 80%. This information, along with the electrical power output, and the wind velocity measured during field operation allowed us to determine the rotor's power coefficient C{sub p}, which had a maximum value of 35%. For the stored energy components measured data indicated that the rectifier, the battery bank, and the inverter operated with average efficiencies of 95%, 78% and 86% respectively. The combined component efficiencies showed a maximum of 17% of the wind energy would be available for water pumping. Since a large amount of wind energy was dissipated during the energy conversion process, new configurations should be analyzed that could avoid such losses in wind pumping systems. (author)

  16. Performance of a 10 kilowatt wind-electric water pumping system for irrigating crops

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States); Molla, S. [Texas A& M Univ., College Station, TX (United States)

    1997-12-31

    A 10 kW wind-electric water pumping system was tested for field crop irrigation at pumping depths from 50 to 120 m. The wind turbine for this system used a permanent magnet alternator that powered off-the-shelf submersible motors and pumps without the use of an inverter. Pumping performance was determined at the USDA-Agricultural Research Service (ARS), Wind Energy Laboratory in Bushland, TX for the 10 kW wind turbine using a pressure valve and a pressure tank to simulate different pumping depths. Pumping performance was measured for two 10 kW wind turbines of the same type at farms near the cities of Garden City, TX and Stiles, TX. The pumping performance data collected at these actual wells compared favorably with the data collected at the USDA-ARS, Wind Energy Laboratory. If utility generated electricity was accessible, payback on the wind turbine depended on the cost of utility generated electricity and the transmission line extension cost.

  17. Applying micro scales of horizontal axis wind turbines for operation in low wind speed regions

    International Nuclear Information System (INIS)

    Pourrajabian, Abolfazl; Ebrahimi, Reza; Mirzaei, Masoud

    2014-01-01

    Highlights: • Three micro-turbines with output power less than 1 kW were designed for operation in low wind speed regions. • In addition to the output power, starting time was considered as a key parameter during the design. • The effects of generator resistive torque and number of blades on the performance of the turbines were investigated. - Abstract: Utilizing the micro scales of wind turbines could noticeably supply the demand for the electricity in low wind speed regions. Aerodynamic design and optimization of the blade, as a main part of a wind turbine, were addressed in the study. Three micro scales of horizontal axis wind turbines with output power of 0.5, 0.75 and 1 kW were considered and the geometric optimization of the blades in terms of the two involved parameters, chord and twist, was undertaken. In order to improve the performance of the turbines at low wind speeds, starting time was included in an objective function in addition to the output power – the main and desirable goal of the wind turbine blade design. A purpose-built genetic algorithm was employed to maximize both the output power and the starting performance which were calculated by the blade-element momentum theory. The results emphasize that the larger values of the chord and twist at the root part of the blades are indispensable for the better performance when the wind speed is low. However, the noticeable value of the generator resistive torque could largely delay the starting of the micro-turbines especially for the considered smaller size, 0.5 kW, where the starting aerodynamic torque could not overcome the generator resistive torque. For that size, an increase in the number of blades improved both the starting performance and also output power

  18. Planning wind turbines in harmony with the landscape. Main report

    International Nuclear Information System (INIS)

    1996-02-01

    The report concerns the revision of the plan for the siting of wind turbines in Loegstoer municipality in Denmark. A major aim of the plan is that the wind turbines should not spoil the beauty of the landscape which also includes coastal areas. The already existing plan is described and records are given of the 132 wind turbines, primarily sited in coastal areas. These turbines have been subjected to arbitrary siting which created a disharmonious landscape view. Wind conditions were assessed with a view to finding suitable sites and a map showing 24 prioritized areas with space for 127 wind turbines, with a total capacity of 500 kW, was produced. It is stated that the Loegstoer landscape would be suited by 40 m high turbines and the flatter areas could take even higher ones. Four possible scenarios are described in detail and a great number of large scale coloured photographs illustrate the text. (AB)

  19. Large scale wind energy conversion system (WECS) design and installation as affected by site wind energy characteristics, grouping arrangement, and social acceptance. [Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ljungstrom, O

    1977-01-01

    The Swedish wind energy prospecting program includes special features of determining site wind characteristics and design of WECS group stations, which are described briefly, such as applications of normalized WDP-Wind Duration Profiles, WHP-Wind Height Profiles and how these are affected by site location and terrain roughness. A set of WEC-Wind Energy Classes (1 to 4) is introduced as an aid in territorial wind energy surveys. A survey of Sweden's WEPA-Wind Energy Producing Areas--with associated distribution over WEC-2-4 is presented. In order to determine the corresponding wind energy production capacity, the problem of optimizing WECS group station design for cost effective energy production per land usage must be solved. Here, the effects of WECS unit size and spacing on specific annual energy production, TWh/km/sup 2/, yr, are analyzed with the use of specific group station models in the 40 to 100 MW capacity range, applying WECS unit sizes 50kW, 1 MW and 5 MW, studying the energy balance for typical group stations. By applying the specific productivity data for 1 to 5 MW systems, a survey of the WEPA-associated wind energy production capacity in Sweden is presented.

  20. Wind power as an electrical energy source in Illinois

    Science.gov (United States)

    Wendland, W. M.

    1982-03-01

    A preliminary estimate of the total wind power available in Illinois was made using available historical data, and projections of cost savings due to the presence of wind-generated electricity were attempted. Wind data at 10 m height were considered from nine different sites in the state, with three years data nominally being included. Wind-speed frequency histograms were developed for day and night periods, using a power law function to extrapolate the 10 m readings to 20 m. Wind speeds over the whole state were found to average over 8 mph, the cut-in point for most wind turbines, for from 40-63% of the time. A maximum of 75% run-time was determined for daylight hours in April-May. A reference 1.8 kW windpowered generator was used in annual demand projections for a reference one family home, using the frequency histograms. The small generator was projected to fulfill from 25-53% of the annual load, and, based on various cost assumptions, exhibited paybacks taking from 14-27 yr.

  1. Small wind turbines - Technical sheet

    International Nuclear Information System (INIS)

    2015-02-01

    This publication first proposes an overview of the technical context of small wind turbines (from less than 1 kW to 36 kW). It discusses issues related to mast height, indicates the various technologies in terms of machine geometry (vertical or horizontal axis), of mast and foundations, of mechanism of orientation with respect to the wind. It also outlines that power curves are not always reliable due to a lack of maturity of techniques and technologies. Other issues are discussed: wind characteristics, and the assessment of the national potential source. The next parts address the regulatory and economic context, environmental impacts (limited impact on landscape, noise), propose an overview of actors and market (supply and demand of small wind turbines in the USA and in France, actors involved in the chain value in France), and give some recommendations for the development of small wind turbines in France. The last part proposes a technical focus on self-consumption by professional in rural areas (production and consumption in farms)

  2. Wind energy resources assessment for Yanbo, Saudi Arabia

    International Nuclear Information System (INIS)

    Rehman, Shafiqur

    2004-01-01

    The paper presents long term wind data analysis in terms of annual, seasonal and diurnal variations at Yanbo, which is located on the west coast of Saudi Arabia. The wind speed and wind direction hourly data for a period of 14 years between 1970 and 1983 is used in the analysis. The analysis showed that the seasonal and diurnal pattern of wind speed matches the electricity load pattern of the location. Higher winds of the order of 5.0 m/s and more were observed during the summer months of the year and noon hours (09:00 to 16:00 h) of the day. The wind duration availability is discussed as the percent of hours during which the wind remained in certain wind speed intervals or bins. Wind energy calculations were performed using wind machines of sizes 150, 250, 600, 800, 1000, 1300, 1500, 2300 and 2500 kW rated power. Wind speed is found to remain above 3.5 m/s for 69% of the time during the year at 40, 50, 60, and 80 m above ground level. The energy production analysis showed higher production from wind machines of smaller sizes than the bigger ones for a wind farm of 30 MW installed capacity. Similarly, higher capacity factors were obtained for smaller wind machines compared to larger ones

  3. Wind energy assessment and wind farm simulation in Triunfo - Pernambuco, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Laerte; Filho, Celso

    2010-09-15

    The Triunfo wind's characterization, in Pernambuco state, situated in Brazilian northeast, and wind power potential assessment study shows a average wind speed of 11.27 m / s, predominant Southeast wind direction, average wind power density of 1672 W/m2 and Weibull parameters shape and scale equal to 2,0 and 12,7 m/s. The wind farm was simulated by using 850kW wind turbines (total of 20MW). The simulated shows AEP of 111,4 GWh, Cf of 62% and 5462 hours of operation by year. The economical simulated results, shows Pay-back of 3 years, TIR = 47% and VAN = 85.506kEuro booths @ 20 years time period.

  4. Economic Selection of Generators for a Wind Farm

    Directory of Open Access Journals (Sweden)

    Omid Alavi

    2015-09-01

    Full Text Available The selection suitable generator for wind turbines will be done based on technical criteria and priorities of the project. In this paper, a method for determining the type of wind turbine generator with an example is explained. In the paper, for a 10kW wind turbine, two generators have been proposed. The first case is a squirrel-cage asynchronous generator coupled to the turbine through the gearbox and directly connected to three phase output. Other PM generators that are directly coupled to the turbine and it is connected to the grid using the inverter. The results show that according to wind conditions, a 10kW permanent magnet generator is more advantageous in terms of energy production.

  5. Navy-New Hampshire Wind Energy Program.

    Science.gov (United States)

    1979-11-01

    wind use for both the MOD-2 and Darrieus wind turbine -generators when located on these peaks. lIT...Horizontal Axis WECS 10 2-4 Darrieus Vertical Axis Wind Turbine 12 2-5 Alcoa Design for 500 kW Vertical Axis WECS 13 3-1 Fraction of Wind Observations... Turbines In 1925, G.J.M. Darrieus patented the concept of a vertical axis wind turbine . Today, the Darrieus design has evolved to a fixed-pitch

  6. Increasing the Kill Effectiveness of High Energy Laser (HEL) Combat System

    Science.gov (United States)

    2015-03-01

    Quantity (estimated) Corvette Mowj 1 Hamzeh 1 Bayandor 2 Kaman 9 Sina 3 Thondor 10 Tir 12 Peykaap 20 Bavar 25 Torpedo and Zolfaghar 8...Kosar Nasr Harpoon (C-802) UAVs/UCAVs Mohajer Ababil Ra’ad 85 Yassir Kanar Fotros Small Boats Kaman/ SINA Thondor C-14 "China Kajami IPS-16 (FAC/FIAC...59 Table 17. Small Boat Data (after Open Som ce Intelligence Project 2011, 32, 34-36, 40) Small Boat AoA #1 #2 #3 #5 #6 IPS-16 Name Kaman/ SINA

  7. Economic perspective of hybrid wind-diesel technology for commercial loads of Dhahran Saudi Arabia: A step towards sustainable future

    Directory of Open Access Journals (Sweden)

    Shaahid S.M.

    2015-01-01

    Full Text Available The governments world-wide are deliberating to promote renewable energy sources such as wind to mitigate increasing demand of energy and to overcome effects of pollution due to to use of fossil fuels. Integration of wind turbine generators (WTG with the diesel plants is pursued widely to reduce dependence on fossil-fuels and to reduce carbon emissions. Literature indicates that commercial/residential buildings in the Kingdom of Saudi Arabia (K.S.A consume an estimated 10 - 40% of the total electric energy generated. The aim of this study is to analyze wind-speed data of Dhahran (East-Coast, K.S.A. to assess the economic feasibility of utilizing hybrid wind-diesel power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kWh. The monthly average wind speeds range from 3.3 to 5.6 m/s. The hybrid systems simulated consist of different combinations of 100 kW commercial WTG supplemented with diesel generators. NREL’s (HOMER Energy’s HOMER software has been employed to perform the techno-economic analysis. The simulation results indicate that for a hybrid system comprising of 100 kW wind capacity together with 175 kW diesel system, the wind penetration (at 37 m hub-height, with 0% annual capacity shortage is 25%. The cost of generating energy (COE, $/kWh from this hybrid wind-diesel system has been found to be 0.121 $/kWh (assuming diesel fuel price of 0.1$/liter. The study exhibits that for a given hybrid configuration, the number of operational hours of diesel gensets decreases with increase in wind farm capacity. Emphasis has also been placed on wind penetration, un-met load, energy production and COE, excess electricity generation, percentage fuel savings and reduction in carbon emissions (relative to diesel-only situation of different hybrid systems, cost break-down of wind-diesel systems, COE of different hybrid systems, etc.

  8. Test results of a 5 kW fully superconducting homopolar motor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. K. [Woosuk University, Wanju (Korea, Republic of); Park, S. H.; Kim, Y.; Lee, S.; Joo, H. G.; Kim, W. S.; Choi, K. [Korea Polytechnic University,Siheong (Korea, Republic of); Hahm, S. Y. [Electrical Engineering and Science Research Institute,Seoul (Korea, Republic of)

    2013-05-15

    The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

  9. Test results of a 5 kW fully superconducting homopolar motor

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, S. H.; Kim, Y.; Lee, S.; Joo, H. G.; Kim, W. S.; Choi, K.; Hahm, S. Y.

    2013-01-01

    The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

  10. Efficiency of a small wind power station

    International Nuclear Information System (INIS)

    Ivanov, K.; Christov, Ch.; Kozarev, N.

    2001-01-01

    The aim of the study is to obtain the optimal solution for wind station both by technical parameters and costs. The energetic characteristics of the wind as a renewable energy source are discussed and assessment of the economical efficiency is made. For the determination of the optimal wind parameters the method of integral wind curves is used. The low power wind generators (0.4 - 1.5 kW) are considered as optimal for the presented wind characteristics

  11. Costa de Cocos 11-kW wind-diesel hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Corbus, D. [National Renewable Energy Lab., Golden, CO (United States); Bergey, M. [Bergey Windpower Company, Norman, OK (United States)

    1997-12-31

    Costa de Cocos is a small resort located in the state of Quintana Roo, Mexico. Using the existing diesel generator, the resort`s power system was retrofitted to a wind-hybrid diesel system. The reason for this retrofit was to supply 24-hour power, to reduce diesel fuel by using wind energy, and to reduce diesel air and noise emissions in order to promote ecotourism. The wind system was installed in October 1996 with cost-shared funding from the U.S. Department of Energy/U.S. Agency for International Development renewable energy program in Mexico. The National Renewable Energy Laboratory (NREL) supplied technical assistance to the project. Discussed in this paper are the system design, installation, and initial performance.

  12. Costa de Cocos 11-kW wind-diesel hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Corbus, D [National Renewable Energy Lab., Golden, CO (United States); Bergey, M [Bergey Windpower Co., Norman, OK (United States)

    1997-09-01

    Costa de Cocos is a small resort located in the state of Quintana Roo, Mexico. Using the existing diesel generator, the resort`s power system was retrofitted to a wind-hybrid diesel system. The reason for this retrofit was to supply 24-hour power, to reduce diesel fuel by using wind energy, and to reduce diesel air and noise emissions in order to promote ecotourism. The wind system was installed in October 1996 with cost-shared funding from the U.S. Department of Energy/U.S. Agency for International Development renewable energy program in Mexico. The National Renewable Energy Laboratory (NREL) supplied technical assistance to the project. Discussed in this paper are the system design, installation, and initial performance.

  13. Needs versus bottlenecks in utilization of wind energy in Egypt

    International Nuclear Information System (INIS)

    El Semery, M.M.

    1991-01-01

    The company AOI Engine Factory in Cairo, Egypt, is involved in the production of renewable energy systems. It is shown, that with respect to wind, Egypt has a good potential. However, along the river Nile wind speed is moderate (<4,4 m/s). The three main wind energy developments in Egypt are discussed. Four 100 kW machines for grid connection have been imported from Denmark. These machines have been adapted for local production and operation circumstances. After a testing period the first batch of 100 turbines is now being manufactured. For water pumping in isolated areas, a 15 kW wind generator with two submergible electric pumps have been tested. For small wind generators a considerable market exists, but a design, suitable for local production and adapted to the local wind regime, is not available yet

  14. Shoosing the appropriate size wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Lynette, R. [FloWind Corp., San Rafael, CA (United States)

    1996-12-31

    Within the past several years, wind turbines rated at 400 kW and higher have been introduced into the market, and some manufacturers are developing machines rated at 750 - 1,000+ kW. This raises the question: What is the appropriate size for utility-grade wind turbines today? The answer depends upon the site where the machines will be used and the local conditions. The issues discussed in the paper are: (1) Site-Related (a) Visual, noise, erosion, television interference, interference with aviation (b) Siting efficiency (2) Logistics (a) Adequacy of roads and bridges to accept large vehicles (b) Availability and cost of cranes for erection and maintenance (c) Capability of local repair/overhauls (3) Cost Effectiveness (a) Capital costs (1) Wind Turbine (2) Infrastructure costs (b) Maintenance costs (4) Technical/Financial Risk. 1 fig., 1 tab.

  15. New 5 kW free-piston Stirling space convertor developments

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Chapman, Peter A., Jr.

    2008-07-01

    The NASA Vision for Exploration of the moon may someday require a nuclear reactor coupled with a free-piston Stirling convertor at a power level of 30-40 kW. In the 1990s, Mechanical Technology Inc.'s Stirling Engine Systems Division (some of whose Stirling personnel are now at Foster-Miller, Inc.) developed a 25 kW free-piston Stirling Space Power Demonstrator Engine under the SP-100 program. This system consisted of two 12.5 kW engines connected at their hot ends and mounted in tandem to cancel vibration. Recently, NASA and DoE have been developing dual 55 and 80 W Stirling convertor systems for potential use with radioisotope heat sources. Total test times of all convertors in this effort exceed 120,000 h. Recently, NASA began a new project with Auburn University to develop a 5 kW, single convertor for potential use in a lunar surface reactor power system. Goals of this development program include a specific power in excess of 140 W/kg at the convertor level, lifetime in excess of five years and a control system that will safely manage the convertors in case of an emergency. Auburn University awarded a subcontract to Foster-Miller, Inc. to undertake development of the 5 kW Stirling convertor assembly. The characteristics of the design along with progress in developing the system will be described.

  16. 2016 Wind Technologies Market Report

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ryan H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bolinger, Mark [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-10

    The U.S. Department of Energy (DOE)’s Wind Technologies Market Report provides an annual overview of trends in the U.S. wind power market. You can find the report, a presentation, and a data file on the Files tab, below. Additionally, several data visualizations are available in the Data Visualizations tab. Highlights of this year’s report include: -Wind power additions continued at a rapid clip in 2016: $13 billion was invested in new wind power plants in 2016. In 2016, wind energy contributed 5.6% of the nation’s electricity supply, more than 10% of total electricity generation in fourteen states, and 29% to 37% in three of those states—Iowa, South Dakota, and Kansas. -Bigger turbines are enhancing wind project performance: Increased blade lengths, in particular, have dramatically increased wind project capacity factors, one measure of project performance. For example, the average 2016 capacity factor among projects built in 2014 and 2015 was 42.6%, compared to an average of 32.1% among projects built from 2004 to 2011 and 25.4% among projects built from 1998 to 2001. -Low wind turbine pricing continues to push down installed project costs: Wind turbine prices have fallen from their highs in 2008, to $800–$1,100/kW. Overall, the average installed cost of wind projects in 2016 was $1,590/kW, down $780/kW from the peak in 2009 and 2010. -Wind energy prices remain low: After topping out at nearly 7¢/kWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped to around 2¢/kWh—though this nationwide average is dominated by projects that hail from the lowest-priced Interior region of the country (such as Texas, Iowa, Oklahoma). These prices, which are possible in part due to federal tax support, compare favorably to the projected future fuel costs of gas-fired generation. -The supply chain continued to adjust to swings in domestic demand for wind equipment: Wind sector employment reached a new high of

  17. Small wind in Canada's energy future : fostering domestic manufacturers

    International Nuclear Information System (INIS)

    Rhoads-Weaver, H.; Gluckman, M.; Weis, T.; Moorhouse, J.; Taylor, A.; Maissan, J.; Sherwood, L.; Whittaker, S.

    2008-01-01

    While large-scale wind power projects are sustaining a 30 per cent annual growth rate, residential-scale wind power is increasingly being adopted in Germany, Japan, and the United States. This presentation discussed the benefits associated with fostering strong domestic wind turbine markets in Canada. Small wind turbine markets typically consist of grid-connected, net-metered turbines of less than 1 kW, off-grid micro-turbines used for battery charging, and net-metered, grid-connected, mid-sized turbines larger than 10 kW used in farming and small business applications. Continued energy price hikes are expected to cause the rapid growth of distributed generation, and nearly half of the world's 10 to 300 kW wind turbine generator manufacturers are located in Canada. However, federal support for small-scale distributed wind systems is lacking, and financial incentives are needed to mature the technology in Canada and leverage private investment. The use of decentralized energy will help to prevent line losses and reduce peak demands on the electricity grid. Use of the technology offers farms and small businesses a revenue stream and can reduce energy costs and demands. It is also expected that small wind jobs in Canada will grow from 50 to 640 by 2025. It was concluded that in order to ensure small wind development, capital cost incentive levels must be coupled with good interconnection and permitting policies. In addition, minimum safety and performance standards must be developed, along with rebate policies and siting analysis methods. tabs., figs

  18. Power Electronics Converters for Wind Turbine Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Liserre, Marco; Ma, Ke

    2012-01-01

    The steady growth of installed wind power together with the upscaling of the single wind turbine power capability has pushed the research and development of power converters toward full-scale power conversion, lowered cost pr kW, increased power density, and also the need for higher reliability. ...

  19. Construction of low-cost, Mod-OA wood composite wind turbine blades

    Science.gov (United States)

    Lark, R. F.

    1983-01-01

    Two sixty-foot, low-cost, wood composite blades for service on 200 kW Mod-OA wind turbines were constructed. The blades were constructed of epoxy resin-bonded Douglas fir veneers for the leading edge sections, and paper honeycombcored, birch plywood faced panels for the afterbody sections. The blades were joined to the wind turbine hub by epoxy resin-bonded steel load take-off studs embedded into the root end of the blades. The blades were installed on the 200 kW Mod-OA wind turbine facility at Kahuku, Hawaii, The blades completed nearly 8,000 hours of operation over an 18 month period at an average power of 150 kW prior to replacement with another set of wood composite blades. The blades were replaced because of a corrosion failure of the steel shank on one stud. Inspections showed that the wood composite structure remained in excellent condition.

  20. Small Wind Turbine Installation Compatibility Demonstration Methodology

    Science.gov (United States)

    2013-08-01

    wind turbine (HAWT) and one 2.9-kW vertical-axis wind turbine (VAWT), we planned to measure radar, acoustic and seismic, turbulence, bird and...non-issue for small turbines . The majority of studies of bat and bird interactions with wind turbines are for large turbines (BPA 2002; Whittam...et al. 2010). The majority of studies of bat and bird interactions with wind energy facil- ities are for utility-scale turbines (> 1 MW) with

  1. Denmark leads in wind energy

    International Nuclear Information System (INIS)

    Aamand, Rene

    1997-01-01

    With an engineering background, Danish manufacturers used a ''bottom-up strategy'' to beat the competition. They start with small-scale 55kW wind turbines, and today offer the MW-sized machines. (author)

  2. Design and operational experience and testing of 50 kW/120 kHz oscillator for 3 MeV, 30 kW DC accelerator

    International Nuclear Information System (INIS)

    Srivastava, S.K.; Bakhtsingh, R.I.; Saroj, P.C.

    2011-01-01

    A 3 MeV, 30 kW dc industrial electron beam Accelerator is being developed at EBC, Kharghar, Navi Mumbai. The 3 MV dc is generated by parallel coupled voltage multiplier operating at 120 kHz. This requires an input voltage of 150 kV-0-150 kV at 120 kHz. This is achieved by 50 kW/120 kHz power oscillator in conjunction with a tuned air-core step-up transformer. Input primary voltage of 6 kV-0-6 kV at 120 kHz is generated by an oscillator using BW1121J2 water cooled triodes in push-pull Colpitts configuration. The tank circuit for the oscillator is formed by the secondary winding inductance of the step-up transformer and capacitance formed by RF feeder electrodes of the voltage multiplier column. Grid feedback for the oscillator is derived by arranging a set of electrodes in the feeder assembly in a capacitive divider configuration. The oscillator is operated in class-C mode with grid leak bias for better efficiency which also has the advantages of self-adjustment with varying load conditions. High power test has been conducted in a simulated test set-up on dummy load up to 30kW. Subsequently, the power oscillator has been tested with HV multiplier at 1MeV level satisfactorily. This paper describes the design, test results and operational experiences of the oscillator. (author)

  3. System Impact Study of the Eastern Grid of Sumba Island, Indonesia: Steady-State and Dynamic System Modeling for the Integration of One and Two 850-kW Wind Turbine Generators

    Energy Technology Data Exchange (ETDEWEB)

    Oswal, R. [Innovation Wind Energy, Inc., Jacksonville, FL (United States); Jain, P. [Innovation Wind Energy, Inc., Jacksonville, FL (United States); Muljadi, Eduard [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hirsch, Brian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Castermans, B. [Winrock International Inc., Little Rock, AR (United States); Chandra, J. [Winrock International Inc., Little Rock, AR (United States); Raharjo, S. [Winrock International Inc., Little Rock, AR (United States); Hardison, R. [Winrock International Inc., Little Rock, AR (United States)

    2016-01-01

    The goal of this project was to study the impact of integrating one and two 850-kW wind turbine generators into the eastern power system network of Sumba Island, Indonesia. A model was created for the 20-kV distribution network as it existed in the first quarter of 2015 with a peak load of 5.682 MW. Detailed data were collected for each element of the network. Load flow, short-circuit, and transient analyses were performed using DIgSILENT PowerFactory 15.2.1.

  4. Wind Turbine Generator System Safety and Function Test Report for the Southwest Windpower H40 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, J.; Link, H.; Meadors, M.; Bianchi, J.

    2002-06-01

    The objective of this test was to evaluate the safety and function characteristics of the Whisper H40 wind turbine. The general requirements of wind turbine safety and function tests are defined in the IEC standard WT01. The testing was conducted in accordance with the National Wind Technology Center (NWTC) Quality Assurance System, including the NWTC Certification Team Certification Quality Manual and the NWTC Certification Team General Quality Manual for the Testing of Wind Turbines, as well as subordinate documents. This safety and function test was performed as part of the U.S. Department of Energy's Field Verification Program for small wind turbines.

  5. DOE/NREL supported wind energy activities in Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Drouilhet, S.

    1997-12-01

    This paper describes three wind energy projects implemented in Alaska. The first, a sustainable technology energy partnerships (STEP) wind energy deployment project in Kotzebue will install 6 AOC 15/50 wind turbines and connect to the existing village diesel grid, consisting of approximately 1 MW average load. It seeks to develop solutions to the problems of arctic wind energy installations (transport, foundations, erection, operation, and maintenance), to establish a wind turbine test site, and to establish the Kotzebue Electric Association as a training and deployment center for wind/diesel technology in rural Alaska. The second project, a large village medium-penetration wind/diesel system, also in Kotzebue, will install a 1-2 MW windfarm, which will supplement the AOC turbines of the STEP project. The program will investigate the impact of medium penetration wind energy on power quality and system stability. The third project, the Alaska high-penetration wind/diesel village power pilot project in Wales will install a high penetration (80-100%) wind/diesel system in a remote Alaskan village. The system will include about 180 kW installed wind capacity, meeting an average village load of about 60 kW. This program will provide a model for high penetration wind retrofits to village diesel power systems and build the capability in Alaska to operate, maintain, and replicate wind/diesel technology. The program will also address problems of: effective use of excess wind energy; reliable diesel-off operation; and the role of energy storage.

  6. Wind Energy Solutions : to bring renewable energy everywhere

    International Nuclear Information System (INIS)

    Leeuw de, J.

    2008-01-01

    This presentation discussed smaller wind turbines designed by the Netherlands-based company Wind Energy Solutions (WES). Ranging between 2.5 kW and 250 kW, the smaller turbines are used in farming applications as well as for factories, in isolated communities, and by utilities with smaller electricity grids. The company also designs off-grid and stand-alone turbines; turbines with equal-sized generators; and turbines that do not require dumploads, batteries, or flywheels. WES turbines have been installed at farms, in parking lots, airports, gas stations, and on the grounds of large office buildings. The company advises that it is important to conduct initial surveys of the location for planned turbines before purchasing them. Legal and financial issues must also be explored, and wind speed data must be obtained in order to select an appropriate turbine. WES has also designed a range of control rooms, turbine cables, and remote monitoring devices for smaller wind turbines, as well as electronic microprocessors and inverters with PLC interfaces. Details of wind turbine installation procedures were included in this presentation. tabs., figs

  7. EurObserv'ER's 2010 wind power barometer

    International Nuclear Information System (INIS)

    Anon.

    2011-01-01

    For the first time in 20 years, the growth of the global wind power market faltered, stumbling by 5.8% to 35.7 GW in 2010. On one hand, the North American market has taken a knock while the European market has slowed down, on the other hand, Asian market growth has crept up steadily and now has a grip on more than half the global market. At the end of 2010 we had 194.5 GW of wind power installed across the world among which 84.3 GW installed in the European Union. Germany and Spain lead the European Union list for installed wind power with respectively 27.21 GW and 20.68 GW but when this capacity is divided by the population, Denmark ranks first with 686, 6 kW/1000 inhabitants followed by Spain with 449.6 KW/1000 inhabitants. 2010 was a record year for offshore wind power. The offshore share of the total wind power market rose to 12.2% in 2010. First available estimates indicate that the European Union's wind energy electricity output for 2010 should reach 147 TWh, which is an 11.2% rise on 2009. In 2010, the global leading manufacturer is probably Chinese. Back to 2009, the top 4 wind turbines suppliers were Vestas (Denmark), GE Wind (Usa), Sinovel (China) and Enercon (Germany). (A.C.)

  8. An assessment on seasonal analysis of wind energy characteristics and wind turbine characteristics

    International Nuclear Information System (INIS)

    Akpinar, E. Kavak; Akpinar, S.

    2005-01-01

    This paper presents seasonal variations of the wind characteristics and wind turbine characteristics in the regions around Elazig, namely Maden, Agin and Keban. Mean wind speed data in measured hourly time series format is statistically analyzed for the six year period 1998-2003. The probability density distributions are derived from the time series data and their distributional parameters are identified. Two probability density functions are fitted to the measured probability distributions on a seasonal basis. The wind energy characteristics of all the regions is studied based on the Weibull and Rayleigh distributions. Energy calculations and capacity factors for the wind turbine characteristics were determined for wind machines of different sizes between 300 and 2300 kW. It was found that Maden is the best region, among the regions analyzed, for wind characteristics and wind turbine characteristics

  9. Wind energy potential in Bulgaria

    International Nuclear Information System (INIS)

    Shtrakov, Stanko Vl.

    2009-01-01

    In this study, wind characteristic and wind energy potential in Bulgaria were analyzed using the wind speed data. The wind energy potential at different sites in Bulgaria has been investigated by compiling data from different sources and analyzing it using a software tool. The wind speed distribution curves were obtained by using the Weibull and Rayleigh probability density functions. The results relating to wind energy potential are given in terms of the monthly average wind speed, wind speed probability density function (PDF), wind speed cumulative density function (CDF), and wind speed duration curve. A technical and economic assessment has been made of electricity generation from three wind turbines having capacity of (60, 200, and 500 kW). The yearly energy output capacity factor and the electrical energy cost of kWh produced by the three different turbines were calculated

  10. Wind turbine integrated multipole permanent magnet generator (PMG)

    Energy Technology Data Exchange (ETDEWEB)

    Vilsboell, N.; Pinegin, A.; Goussarov, D.

    1996-01-01

    Designed permanent magnet generator (PMG - 20 kW) possesses a number of advantages: it makes possible to replace gearbox, the generator and possibly the hub of the wind turbine by combining wind rotor with external rotor of the generator; use of rare earth magnets Nd-Fe-B allows to reduce mass and dimensions of the generator; use of the PMG for wind turbines increases the reliability of the construction during the life time, comparing to the conventional design (gearbox, asynchronous generator). The test of the PMG -20 kW informs that design method, developed for calculation of multipole permanent magnet generators is correct in general and meets engineering requirements. The calculation uncertainty of the magnetic system and output characteristics does not exceed 2-3%. The test shows, that the maximum efficiency of the PGM - 20 kW with full load can be achieved as high as 90-91.5% and excels the efficiency of the traditional system `generator-gearbox` by 4-5.5%. Designing permanent magnet generator, it is recommended to take into account voltage stabilization (capacitance). Efficiency is expected to be higher, mass and production cost of the generator can be reduced by 25-30%. The frequency converter shall be used not only for control of rotational speed, but also to obtain sinusoidal capacitive current on the generator side. For PMG - 20 kW the angle between voltage and current should be within the range 0-23%. (au)

  11. Sliding Mode Control of PMSG Wind Turbine Based on Enhanced Exponential Reaching Law

    DEFF Research Database (Denmark)

    Mozayan, Seyed Mehdi; Saad, Maarouf; Vahedi, Hani

    2016-01-01

    This paper proposes a Sliding Mode Control (SMC) based scheme for a variable speed, direct-driven Wind Energy Conversion Systems (WECS) equipped with Permanent Magnet Synchronous Generator (PMSG) connected to the grid. In this work, diode rectifier, boost converter, Neutral Point Clamped (NPC......) inverter and L filter are used as the interface between the wind turbine and grid. This topology has abundant features such as simplicity for low and medium power wind turbine applications. It is also less costly than back-to-back two-level converters in medium power applications. SMC approach demonstrates...... is explored by simulation study on a 4 kW wind turbine, and then verified by experimental tests for a 2 kW set-up....

  12. Concept Testing of a Simple Floating Offshore Vertical Axis Wind Turbine

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Schmidt Paulsen, Uwe; Aagaard Madsen, Helge

    2013-01-01

    The wind energy community is researching new concepts for deeper sea offshore wind turbines. One such concept is the DeepWind concept. The concept is being assessed in a EU-FP7 project, called DeepWind. Objectives of this project are to assess large size wind turbines (5-20MW) based on the concept...... varying wind and wave conditions, and to compare such behaviour with computer code calculations. The concept turbine was designed and constructed by the project task partners, and all parts were assembled and installed at sea in the Roskilde fjord right next to DTU Risø campus. The turbine is under....... One task in the project is to test a 1kW concept rotor (not a scaled down MW size rotor) partly under field conditions in a fjord in Denmark, partly in a water tank under controlled conditions in Netherlands. The objective of testing the 1kW concept turbine is to verify the dynamical behaviour under...

  13. Economics for wind turbines in Denmark. Investments, operation and maintenance costs for selected vintages of turbines

    International Nuclear Information System (INIS)

    Hjuler Jensen, P.; Morthorst, P.E.; Skriver, S.; Rasmussen, M.; Larsen, H.; Hansen, L.H.; Nielsen, P.; Lemming, J.

    2002-10-01

    During the last two decades of operational experience with wind turbines in Denmark, a number of investigations on wind energy economics have been carried out on behalf of the Danish Energy Agency. The aim of this study has been to analyse the development of investments cost, O and M-cost, insurance costs etc. including the economic and technical lifetime of wind turbines. Based on a questionnaire and an existing database, time series for O and M-cost components are established going back to the early 80's. These time series are used to analyse the development of O and M-costs during the lifetime of different turbine sizes and vintages. A major issue of the project is to use the results achieved for older turbines (55kW to 150 kW) to establish an expected development of O and M-costs for newer larger turbines, typically of the 500kW to 750kW sizes. (au)

  14. Design of airborne wind turbine and computational fluid dynamics analysis

    Science.gov (United States)

    Anbreen, Faiqa

    Wind energy is a promising alternative to the depleting non-renewable sources. The height of the wind turbines becomes a constraint to their efficiency. Airborne wind turbine can reach much higher altitudes and produce higher power due to high wind velocity and energy density. The focus of this thesis is to design a shrouded airborne wind turbine, capable to generate 70 kW to propel a leisure boat with a capacity of 8-10 passengers. The idea of designing an airborne turbine is to take the advantage of higher velocities in the atmosphere. The Solidworks model has been analyzed numerically using Computational Fluid Dynamics (CFD) software StarCCM+. The Unsteady Reynolds Averaged Navier Stokes Simulation (URANS) with K-epsilon turbulence model has been selected, to study the physical properties of the flow, with emphasis on the performance of the turbine and the increase in air velocity at the throat. The analysis has been done using two ambient velocities of 12 m/s and 6 m/s. At 12 m/s inlet velocity, the velocity of air at the turbine has been recorded as 16 m/s. The power generated by the turbine is 61 kW. At inlet velocity of 6 m/s, the velocity of air at turbine increased to 10 m/s. The power generated by turbine is 25 kW.

  15. Analysis of power curves of Danish and foreign wind turbines

    International Nuclear Information System (INIS)

    Petersen, H.

    1995-12-01

    This report describes an analysis of power curves for a number of wind turbines, 30 Danish and 17 foreign - European - wind turbines. The investigation is limited to wind turbines of 150 kW capacity and greater, and to wind turbines for which a power curve is available. The power curves are transformed into a common, uniform presentation in order to facilitate the succeeding treatment, which primarily is the calculation of the production of electrical energy yielded per year. From the known data of the wind turbine, equipped generator power and rotor area and the area swept by the blades, the specific electrical production is calculated in three terms: yield per square meter of rotor area, yield per kW generator power and yield per square meter and per kilowatt generator power. Based on these findings a number of comparisons are established, such as comparisons of conceptual designs and technical- economical evaluations. (au)

  16. Economic feasibility of developing wind turbines in Aligoodarz, Iran

    International Nuclear Information System (INIS)

    Mohammadi, Kasra; Mostafaeipour, Ali

    2013-01-01

    Highlights: • Three hourly long term measured wind speed data from 2005 to 2009 for city of Aligoodarz in Iran was analyzed. • Wind power density and wind energy density of the region were estimated using Weibull distribution. • Performance of six different wind turbine models were analyzed. • Economic evaluation was performed and installing of E-3120 (50 kW) model turbine was suggested. - Abstract: This study evaluates the economic feasibility of electricity generation using wind turbines in city of Aligoodarz situated in the west part of Iran. For this purpose, the wind energy potential and its characteristics were assessed in terms of diurnal, monthly and annual analysis using five years measured wind speed data from 2005 to 2009 at 10 m height. The analysis results specified a nearly stable wind pattern in different hours and months of the year which demonstrated more suitability of the region for wind energy harnessing to meet the electricity demand in all time intervals throughout the year. According to Pacific Northwest Laboratory (PNL) wind power classification, the wind resource in Aligoodarz falls in class 3 and the location was recognized as a moderate location for wind energy development. The economic feasibility of six different wind turbines with rated powers ranging from 20 to 150 kW was evaluated. Among all turbines examined, the E-3120 wind turbine was introduced as the most attractive option for installation

  17. Wind energy in the Netherlands

    International Nuclear Information System (INIS)

    Bruijne, R. de

    1990-01-01

    Wind energy is a 'winning reality' in the Netherlands. This is apparent from the results by researchers, industry and the market. During recent years the market has acquired confidence in wind energy. At the start of 1987 there was about 15 MW of installed wind power in the Netherlands. Halfway through 1990 this has almost quadrupled, with 45 MW in operation and 35 MW under construction. The power companies have specific capital expenditure plans for further growth to approximately 400 MW by 1995. This investment scheme will consist of existing turbines (< 600 kW). (Author)

  18. Superconducting wind turbine generators

    DEFF Research Database (Denmark)

    Abrahamsen, Asger Bech; Mijatovic, Nenad; Seiler, Eugen

    2010-01-01

    , the main challenge of the superconducting direct drive technology is to prove that the reliability is superior to the alternative drive trains based on gearboxes or permanent magnets. A strategy of successive testing of superconducting direct drive trains in real wind turbines of 10 kW, 100 kW, 1 MW and 10......We have examined the potential of 10 MW superconducting direct drive generators to enter the European offshore wind power market and estimated that the production of about 1200 superconducting turbines until 2030 would correspond to 10% of the EU offshore market. The expected properties of future...... offshore turbines of 8 and 10 MW have been determined from an up-scaling of an existing 5 MW turbine and the necessary properties of the superconducting drive train are discussed. We have found that the absence of the gear box is the main benefit and the reduced weight and size is secondary. However...

  19. Analysis operating and maintenance cost of Danish wind turbines in 1993

    International Nuclear Information System (INIS)

    Godtfredsen, F.

    1994-10-01

    A study of operation and maintenance (O and M) cost of Danish wind turbines has been carried out. The study is based on a questionnaire survey by the wind turbine owners association. The study shows a significant decline in the O and M cost from 55 kW machines installed in 1980-87 to modern machines. In 1993, the average total O and M cost for 55 kW and 150 kW turbines was approximately 0.22 DKK/kWh and 0.07 DKK/kWh, respectively. For 150 kW turbines, insurance and administration costs amounted to 0.04 DKK/kWh while repair and maintenance costs came to 0.03 DKK/kWh. In 1993, repair and maintenance cost were significantly higher for older vintages of 55 kW and 150 kW turbines, but it is not possible based on this study to conclude whether increasing O and M costs generally comes with increasing age. The statistical basis of this study is not large enough to conclude whether there are positive scale effects for ST's from 105 kW. Similarly, because of relatively few large WT are older than 10 years, it is not possible based on this study to predict the size of major future repair costs/reinvestments. To estimate the O and M costs more exactly, a larger empirical basis is needed. (au) (8 tabs., 17 ills., 11 refs.)

  20. Main Coast Winds - Final Scientific Report

    Energy Technology Data Exchange (ETDEWEB)

    Jason Huckaby; Harley Lee

    2006-03-15

    The Maine Coast Wind Project was developed to investigate the cost-effectiveness of small, distributed wind systems on coastal sites in Maine. The restructuring of Maine's electric grid to support net metering allowed for the installation of small wind installations across the state (up to 100kW). The study performed adds insight to the difficulties of developing cost-effective distributed systems in coastal environments. The technical hurdles encountered with the chosen wind turbine, combined with the lower than expected wind speeds, did not provide a cost-effective return to make a distributed wind program economically feasible. While the turbine was accepted within the community, the low availability has been a negative.

  1. Precipitation, temperature and wind in Norway: dynamical downscaling of ERA40

    Energy Technology Data Exchange (ETDEWEB)

    Barstad, I.; Sorteberg, A.; Flatoey, F. [Bjerknes Centre for Climate Research, Bergen (Norway); Deque, M. [Meteo France, EAC/GMGEC/CNRM, Toulouse (France)

    2009-11-15

    A novel downscaling approach of the ERA40 (ECMWF 40-years reanalysis) data set has been taken and results for comparison with observations in Norway are shown. The method applies a nudging technique in a stretched global model, focused in the Norwegian Sea (67 N, 5 W). The effective resolution is three times the one of the ERA40, equivalent to about 30 km grid spacing in the area of focus. Longer waves (40 solution, and thus the large-scale circulation is similar in the two data sets. The shorter waves are free to evolve, and produce high intensities of winds and precipitation. The comparison to observations incorporate numerous station data points of (1) precipitation (357), (2) temperature (98) and (3) wind (10), and for the period 1961-1990, the downscaled data set shows large improvements over ERA40. The daily precipitation shows considerable reduction in bias (from 50 to 11%), and twofold reduction at the 99.9 percentile (from -59 to -29%). The daily temperature showed a bias reduction of about a degree in most areas, and relative large RMSE reduction (from 7.5 to 5.0 C except winter). The wind comparison showed a slight improvement in bias, and significant improvements in RMSE. (orig.)

  2. Finance and banking for wind energy

    Energy Technology Data Exchange (ETDEWEB)

    Rave, Klaus [Investitionsbank Schleswig-Holstein (Germany)

    1999-01-01

    Installed wind power capacity in Schleswig-Holstein has grown from 2 MW in 1988 to about 600 MW in 1997; about 10% of the total power demand. The target of 20 to 25% by 2010 should easily be exceeded. Cost per kW of installed capacity has fallen from DM 3,350 in 1990 to DM 1,700 in 1997. Estimates for the world market for wind power are given. Criteria for evaluating the financing of a build, operate, transfer wind energy project are set out. (uk)

  3. Finance and banking for wind energy

    Energy Technology Data Exchange (ETDEWEB)

    Rave, Klaus [Investitionsbank Schleswig-Holstein (Germany)

    1999-04-01

    Installed wind power capacity in Schleswig-Holstein has grown from 2 MW in 1988 to about 600 MW in 1997; about 10% of the total power demand. The target of 20 to 25% by 2010 should easily be exceeded. Cost per kW of installed capacity has fallen from DM 3,350 in 1990 to DM 1,700 in 1997. Estimates for the world market for wind power are given. Criteria for evaluating the financing of a build, operate, transfer wind energy project are set out. (uk)

  4. Development of a wind converter and investigation of its operational function. Part 1: Technical description of the wind energy converter

    Science.gov (United States)

    Molly, J. P.; Steinheber, R.

    1982-11-01

    A 10 kW wind energy converter was developed by using as far possible standard serial production parts. The design criteria and the description of the essential machinery components of the MODA 10 wind energy converter are discussed. For some special load cases the safety calculation of the important components is shown. The blade control system which qualified for small wind energy converters, is explained. Weight and cost of the MODA 10 are considered.

  5. Some answers to power generation lie blowing in the wind

    Energy Technology Data Exchange (ETDEWEB)

    1975-10-02

    An assessment of wind power generation schemes by the Energy Technology Support Unit is reported. The capital cost of large, efficient windmills should be around 100--200 Pounds per installed kW and an optimum size for a single wind rotor would be 1 MW.

  6. Power converter with maximum power point tracking MPPT for small wind-electric pumping systems

    International Nuclear Information System (INIS)

    Lara, David; Merino, Gabriel; Salazar, Lautaro

    2015-01-01

    Highlights: • We implement a wind electric pumping system of small power. • The power converter allowed to change the operating point of the electro pump. • Two control techniques were implemented in the power converter. • The control V/f variable allowed to increase the power generated by the permanent magnet generator. - Abstract: In this work, an AC–DC–AC direct-drive power converter was implemented for a wind electric pumping system consisting of a permanent magnet generator (PMG) of 1.3 kW and a peripheral single phase pump of 0.74 kW. In addition, the inverter linear V/f control scheme and the maximum power point tracking (MPPT) algorithm with variable V/f were developed. MPPT algorithm seeks to extract water in a wide range of power input using the maximum amount of wind power available. Experimental trials at different pump pressures were conducted. With a MPPT tracking system with variable V/f, a power value of 1.3 kW was obtained at a speed of 350 rpm and a maximum operating hydraulic head of 50 m. At lower operating heads pressures (between 10 and 40 m), variable V/f control increases the power generated by the PMG compared to the linear V/f control. This increase ranged between 4% and 23% depending on the operating pressure, with an average of 13%, getting close to the maximum electrical power curve of the PMG. The pump was driven at variable frequency reaching a minimum speed of 0.5 times the rated speed. Efficiency of the power converter ranges between 70% and 95% with a power factor between 0.4 and 0.85, depending on the operating pressure

  7. Repowering of wind farms - A case study

    Energy Technology Data Exchange (ETDEWEB)

    Nivedh, B.S. [Quality Engineering and Software Technologies, Bangalore (India); Devi, R.P.K. [College of Engineering. Power Systems Engineering, Guindy (India); Sreevalsan, E. [Gamesa Wind Turbines India Private Limited, Chennai (India)

    2012-07-01

    The main objective of the study is to devise a method for assessing the repowering potential and to improve the energy output from the wind farms and also to understand the impact on the power quality due to repowering. With repowering, the first-generation wind turbines can be replaced with modern multi-megawatt wind turbines. To carry-out the study an old wind farm located at Kayathar, Tamilnadu is selected. The wind farm was commissioned in 1990's with a capacity of 7.35MW, which consists of 36 Wind Turbines each with the capacity of 200kW and 225kW. The present annual energy generation of the wind farm is 7350MWhr with the plant load factor of 11.41%. The intent of this study is to predict the annual energy output of the wind farm after the repowering using WAsP (Wind Atlas Analysis Application Program). Further this study analyses the power quality issues of the various Wind Turbines. In addition, the main feeder, in which the wind farm which is taken for the study also modeled and the impact on power quality due to repowering also studied. Simulations were carried out using MATLAB. The results are analyzed to understand the significance of repowering to overcome the energy crisis of the nation since the best locations for wind in India are occupied by old wind turbines. The following are the observations and conclusions from the above study. Plant load factor (PLF) increased to 24 %, Energy yield increased to more than 4 times and the capacity of the wind farm became double. And in the view of power quality, comparing to the existing Feeder, Repowered Feeder having less reactive power consumption, voltage variations and flickers except the harmonic distortion. (Author)

  8. Survey of variable speed operation of wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Ola; Hylander, J.; Thorborg, K. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1996-12-01

    During the last five years the production and operation of variable-speed wind turbines have advanced from a few experimental machines to a serial production of at least 10 MW of installed capacity of variable speed machines per week. The rated power of serial wind turbines is today around 600 kW and for the prototypes up to 3000 kW. Variable speed operation of wind turbines can be obtained with several different types of electrical generating systems, such as synchronous generators with diode rectifiers and thyristor inverters or induction generators with IGBT-converters, for the wide speed range. For the narrow speed range the wound motor induction generator with a rotor cascade or a controlled rotor resistance is preferable. The development of permanent magnetic material and the reduction of costs of the power electronic components have opened a possibility of designing cost-effective wind turbines with a directly driven generator. Pitch control together with variable speed will make it possible to limit the power variation within a few percent, 2 to 5 %, of the rated power. 7 refs, 4 figs, 2 tabs

  9. Socio-economic overview of wind energy conversion systems

    International Nuclear Information System (INIS)

    Hardy, D.R.

    1992-01-01

    A social scientist's perspective is presented on the socio-economic impacts of wind energy conversion systems (WECS) in Ontario. The main organization for delivering electricity in Ontario is Ontario Hydro. This utility has two WECS, an experimental 3.5 kW generator and a hybrid wind/diesel facility at a remote northern community. Ontario Hydro is reviewing its supply options and anticipates wind power would likely be used in niche applications involving off-grid hybrid systems where the cost of displaced generation is high. On-grid applications would likely be in the form of dispersed non-utility generation. The potential contribution of wind power to Ontario's electricity supply mix could be as little as 1 MW by the year 2000 or as high as 40 MW by the year 2014, depending on costs and technological developments. Socio-economic criteria used by the utility for assessing individual supply options include job creation, regional economic development, local community impacts, social acceptance, and distribution of risks and benefits. Initial observations of potential effects of WECS are discussed, including site selection, manufacturing, construction, and operation. Barriers to implementation of WECS in Ontario include the limited number of good wind sites, the intermittent nature of WECS power, and the currently uneconomic nature of WECS for bulk electricity systems. However, WECS have environmentally attractive features and are socially acceptable. 10 refs., 3 figs

  10. Enormous achievement of the wind power in India; Indo no fusha no osorubeki jitsuryoku

    Energy Technology Data Exchange (ETDEWEB)

    Ida, H

    1996-10-27

    This paper presents the situation of the wind power generation in India. Indian wind turbine capacity sums to 600MW as the 4th power in the world. The financial combine NEPC has erected 3/4 of the total capacity. The joint enterprise NEPC-MYCON of NEPC and Danish wind turbine manufacturer imports main bodies, and produces only towers in India. The enterprise erected 1,500 systems (450MW) in 1989-95 receiving benefit from cheaper real estate and labor costs. As the author visited the wind farm including 10 250kW class wind power generation systems erected in 1994, wind velocity was a maximum of 6.3m/s, however, it is 10m/s on average in the monsoon period from April to July. The blades of wind turbines under erection are made of fiber reinforced plastics water-proofed by polyester resin. Generated power is sold to local governments, or wind turbines are sold to various private enterprises for private power generation or to local governments. Erection cost can be collected with power sales benefit by 6 years. Since power supply capability in India is only 40% of power demand, low-cost wind power generation is promising. 5 figs.

  11. Wind energy development: Danish experiences and international options

    International Nuclear Information System (INIS)

    Frandsen, S.; Hasted, F.; Josephsen, L.; Nielson, J.H.

    1989-01-01

    In Denmark, wind energy makes a visible contribution to energy planning. Since 1976, over 1,800 wind turbine units have been installed in Denmark, representing a capacity of ca 140 MW out of a grid capacity of 8,000 MW. These units are all grid-connected and the unit sizes range from 55 kW to 400 kW. The installed wind energy capacity represents a substantial development of technologies for wind energy utilization during the last 15 years, involving participation from research institutes, electric utilities, private industry, and the national energy administration. A considerable improvement of the technical and economic performance of wind turbines, along with increased reliability and durability, has been strongly supported by comprehensive government programs. In 1985, another large construction program was initiated which will add 100 MW wind power capacity by the end of 1990. Parallel with commercial development, Danish utilities have developed and constructed a number of megawatt-size wind turbines on a pilot basis. In general terms the wind energy resources in Denmark are rather good, and many suitable sites exist, but installed wind energy capacity is limited by the high population density. Consequently, research is being conducted on the feasibility of offshore wind turbines. In other countries, wind energy developments similar to those in Denmark are taking place. In communities with no connection to the national grid, special attention should be paid to hybrid systems such as wind-diesel and hydro-wind systems. A substantial transfer of technology is required for facilitating significant development of hybrid systems in developing countries. 11 refs., 7 figs., 2 tabs

  12. The use of wind data with an operational wind turbine in a research and development environment

    Science.gov (United States)

    Neustadter, H. E.

    1979-01-01

    It is noted that in 1976, 17 candidate sites were identified for detailed evaluation as potential sites for installation of large, horizontal axis Wind Turbines (WT). Attention is given to the Mod-OA, a 200 kW WT located in Clayton, New Mexico. The discussion covers the meteorological data collected, some of the analyses based on these wind data as well as additional areas currently being investigated in relation to these data.

  13. Design and fabrication of a low-cost Darrieus vertical-axis wind-turbine system, volume 2

    Science.gov (United States)

    1983-03-01

    The fabrication, installation, and checkout of 100-kW 17 meter vertical axis wind turbines is described. Turbines are Darrieus-type VAWIs with rotors 17 meters and 25.15 meters in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18-mph wind regime using 12% annualized costs. Four turbines were produced; three are installed and are operable. Contract results are documented.

  14. Development of electric machines with superconducting windings

    International Nuclear Information System (INIS)

    Glebov, I.A.; Novitskij, V.G.

    1977-01-01

    Some studies are discussed performed in the USSR with the aim to develop the most promising electrical machines with superconducting windings, i.e. powerful (more than 1 MW) cryoturbogenerators for power heat and nuclear plants, electric motors of more than 10,000 kW, reverse systems of an electric driver and unipolar generators for electrolysis industry. The design and performances of the simulator of a 1500 kW cryoturbogenerator are given. Problems of coooling and oscillations of the simulator rotor are considered

  15. Tuno Knob Offshore Wind Farm

    International Nuclear Information System (INIS)

    Madsen, P.S.

    1996-01-01

    In 1995 Midtkraft Power Company built Denmark's second offshore wind farm as a demonstration project. The project purpose is first of all to investigate the environmental aspects of offshore wind energy. The two primary objects are to study the impact on bird life and to test different methods for predicting the visual effect. The wind farm consists of 10 pitch-regulated Vestas V39 500 kW wind turbines placed on box caisson foundations in a shallow water area 6 km east of Jutland. The project has been implemented successfully under a very narrow time schedule, and during the first 6 months in operation, the production has been approx. 30% higher than expected. (author)

  16. Optimal multivariable control of a wind turbine with variable speed

    NARCIS (Netherlands)

    Steinbuch, M.

    1987-01-01

    The control system design for a 310 kW horizontal axis wind energy conversion system with a synchronous generator and DC link is investigated. Because the wind turbine system has multiple inputs (pitch angle, field vollage alld delay angle), and multiple outputs, (speed and power), and because the

  17. Analysis of the energy production of Danish wind turbines 1981-1992

    International Nuclear Information System (INIS)

    Godtfredsen, F.

    1995-10-01

    A study of 1981-1992 energy production from Danish wind turbines has been carried out. The study is based on production data from the greater part of Danish wind turbines, as reported by the turbine owners and published in the magazine Naturlig Energi. The study shows a significant rise in the average energy production from 55 kW turbines erected in the early eighties to modern 150-500 kW turbines erected in 1992. The average yearly energy production of new turbines raised from rather more than 400 MWh per square meter swept rotor area in 1981 to 750-900 MWh in 1992. The main reasons for this increase are the development of larger wind turbines (with larger generator capacity, rotor area and hub height), more efficient turbines. (au) 18 tabs., 14 ills., 8 refs

  18. Does noise from wind turbines change due to age?

    International Nuclear Information System (INIS)

    Andersen, B.; Jakobsen, J.

    1995-06-01

    It has been discussed whether the noise from a wind turbine increases due to wear of the mechanical parts or to pollution of the rotor blades. If this is so it should be taken into consideration at the design stage. The noise from wind turbines that had been measured several years before was measured again, and results were compared. A number of modifications of the same wind turbine was made throughout a period of two years during which noise was measured several times. No evidence that noise increases in accordance with the age of the windmill was found. A 75 kW wind turbine seems to have an unchanged A-weighted source strength L WA after a period of 6 years. The level of the tones in the noise from the large generator engaged had increased slightly. The noise from operation of the small generator showed a pronounced increase of one tone (approximately 10 dB), while two other tones were largely unchanged. In the case of periodic measurements of the noise from a 300 kW wind turbine, the gearbox tone noise was found to change markedly, without any obvious pattern. The large, apparently random, fluctuations mask any tendency towards changes of the tone level with time. Repeated measurements of four identical 100 kW wind turbines, show a general tendency towards an increase of the A-weighted source strength (L WA ). The increase of L WA between 1 and 2.7 dB, was found mainly in the frequency range 800 Hz to 3 kHz. The level of the third octave band, which includes a weak gearbox tone (315 Hz), seemed unchanged. Other measurements indicate a constant level of noise during the first three years of operation. (AB)

  19. An analysis of UK wind farm statistics

    International Nuclear Information System (INIS)

    Milborrow, D.J.

    1995-01-01

    An analysis of key data for 22 completed wind projects shows 134 MW of plant cost Pound 152 million, giving an average cost of Pound 1136/kW. The energy generation potential of these windfarms is around 360 GWh, derived from sites with windspeeds between 6.2 and 8.8 m/s. Relationships between wind speed, energy production and cost were examined and it was found that costs increased with wind speed, due to the difficulties of access in hilly regions. It also appears that project costs fell with time and wind energy prices have fallen much faster than electricity prices. (Author)

  20. Effect of fall wind on wind power generation; Furyoku hatsuden ni okeru dashikaze no koka

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, H [Nihon University, Tokyo (Japan)

    1997-11-25

    Wind conditions in Arakawa Town, Niigata Prefecture, were surveyed by anemometers and anemoscopes installed at 3 different points, and the data are analyzed to develop the prediction model for investigating possibility of introduction of wind mills there. Outlined herein is power generated by fall wind by comparing predicted power availability with the actual results. In order to investigate possibility of power generation by fall wind, the wind conditions and power availability are simulated using the observed wind condition data. Predicted wind velocity involves a large error at a point where frequency of prevailing wind direction is high, and direction in which average wind velocity is high coincides with direction in which land is slanted at a high slope. Fall wind occurs locally for geographical reasons. Location of the wind mill must be carefully considered, because it is complex, although potentially gives a larger quantity of power. A wind mill of 400kW can produce power of around 600MWh annually, when it is located at the suited site confirmed by the wind condition analysis results. 6 refs., 5 figs., 6 tabs.

  1. IMPER: Characterization of the wind field over a large wind turbine rotor - final report; Improved performance

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt Paulsen, U.; Wagner, R.

    2012-01-15

    A modern wind turbine rotor with a contemporary rotor size would easily with the tips penetrate the air between 116 m and 30 m and herby experience effects of different wind. With current rules on power performance measurements such as IEC 61400-121 the reference wind speed is measured at hub height, an oversimplification of the wind energy power over the rotor disk area is carried out. The project comprised a number of innovative and coordinated measurements on a full scale turbine with remote sensing technology and simulations on a 500 kW wind turbine for the effects of wind field characterization. The objective with the present report is to give a short overview of the different experiments carried out and results obtained within the final phase of this project. (Author)

  2. WindPACT Reference Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rinker, Jennifer [Former National Renewable Energy Laboratory (NREL) employee

    2018-04-02

    To fully understand how loads and turbine cost scale with turbine size, it is necessary to have identical turbine models that have been scaled to different rated powers. The report presents the WindPACT baseline models, which are a series of four baseline models that were designed to facilitate investigations into the scalings of loads and turbine cost with size. The models have four different rated powers (750 kW, 1.5 MW, 3.0 MW, and 5.0 MW), and each model was designed to its specified rated power using the same design methodology. The models were originally implemented in FAST_AD, the predecessor to NREL's open-source wind turbine simulator FAST, but have yet to be implemented in FAST. This report contains the specifications for all four WindPACT baseline models - including structural, aerodynamic, and control specifications - along with the inherent assumptions and equations that were used to calculate the model parameters. It is hoped that these baseline models will serve as extremely useful resources for investigations into the scalings of costs, loads, or optimization routines.

  3. Lighter-than-air wind turbines in remote communities

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, M.; Ferguson, F.; Akhiwu, K. [Magenn Power Inc., Ottawa, ON (Canada)

    2008-07-01

    This paper presented the 100 kW Magenn Air Rotor System (MARS) drag-type wind turbine system that is based on lighter-than-air technology. It consists of an axisymmetric helium-filled core balloon, anchored to the ground via a tether containing high-tenacity fibers as well as copper conductors. The torque for the rotation is provided by sails fixed to the surface of the balloon. A winch on the ground allows the tether to be reeled in and out up to a height of 300 m. The feasibility of using the system in 2 specific local community-owned power network was investigated. The results of initial testing were discussed. Highly consistent winds at 300 m altitude were found to result in power densities 3 to 4 times what is available to a conventional 100 kW wind turbine. The inflatable structures reduce capital costs as well as equipment and shipping costs associated with installation in remote areas. It was concluded that the MARS system is very simple to install and despite its large size, no cranes or oversized vehicles are needed to deploy the system. The high-altitude wind power using tethered wind turbine devices has the potential to open up new wind resources in areas that are not served by conventional turbines. 6 refs., 3 tabs., 2 figs.

  4. Appraising the viability of wind energy conversion system in the Peninsular Malaysia

    International Nuclear Information System (INIS)

    Akorede, Mudathir Funsho; Mohd Rashid, Muhd Ikram; Sulaiman, Mohd Herwan; Mohamed, Norainon Binti; Ab Ghani, Suliana Binti

    2013-01-01

    Highlights: • Capacity factors and annual turbine availability are computed for case study sites. • Annual energy yield and levelised cost of energy are determined for each site. • Results obtained reveal that large-scale wind energy is not viable in Malaysia. • 57.58 W/m 2 power density and 4.39% capacity factor are obtained for the best site. • Wind speeds standard deviation is a good index for sites ranking for energy yield. - Abstract: To harvest the wind energy resource for power production, it is crucially important to carry out a preliminary study to understand the site-specific nature of wind at the intended site. Such knowledge is required to estimate the performance of a wind energy project in the area. This study investigates the wind energy potential for production of electric power in the Peninsular Malaysia. Wind speed data of six selected sites across the country collected over a period of 10–20 years are employed for the study. A statistical analysis of the wind speeds is carried out using the Weibull distribution model. Six identified commercially available wind turbines with rated capacity ranging from 20 kW to 1500 kW, with different speed parameters are simulated at the selected locations. Of the six sites evaluated in this paper, it is revealed that Mersing, having the highest monthly average wind speed and consequently the most viable, produces an average power density of 57.58 W/m 2 with a capacity factor of only 4.39%. This is equivalent to 378 MW h energy production per annum at a levelised cost of 22 cents per kW h. This study also shows that the standard deviation of the average monthly wind speeds is a better factor than the average annual wind speed for ranking of selected sites in terms of annual energy production. Overall, the results obtained from this investigation show that large-scale wind energy is not viable in Malaysia due to weak wind regimes; however, small-scale wind energy system may be economically viable in a

  5. Low-power wind plants

    International Nuclear Information System (INIS)

    Kovalenko, V.I.; Shevchenko, Yu.V.; Shikhajlov, N.A.; Kokhanevich, V.P.; Tanan, G.L.

    1993-01-01

    Design peculiarities, as well as the prospects of development and introduction of the low-power (from 0.5 up to 4 kW) wind power plants (WPP) are considered. The variants of WPP with vertical and horizontal rotation axis are described. The data characterizing cost and structure of expenditures on WPP manufacture and operation are given

  6. Advancement, construction and testing of a 200 kW single-blade rotor. Weiterentwicklung, Bau und Erprobung eines 200 kW-Einblattrotors

    Energy Technology Data Exchange (ETDEWEB)

    Helms, L.; Knuenz, D.; Mickeler, S.; Ruehmann, H.R.; Stemme, H.; Wendt, H.; Wodarg, N.

    1991-03-01

    The research project promoted the design, construction, testing and demonstration of a medium-sized, isolated wind power plant with an output of ca. 200 kW and a rotor diameter of 25 m for electric power supplies to a greenhouse gardener's shop in East Frisia, Germany. The control of the connecting and disconnecting constant loads was to be developed for optimum utilization of the wind supply. The report discusses the project stages placing emphasis on the operational results. (BWI).

  7. Final Technical Report - Kotzebue Wind Power Project - Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Rana Zucchi, Global Energy Concepts, LLC; Brad Reeve, Kotzebue Electric Association; DOE Project Officer - Doug Hooker

    2007-10-31

    The Kotzebue Wind Power Project is a joint undertaking of the U.S. Department of Energy (DOE); Kotzebue Electric Association (KEA); and the Alaska Energy Authority (AEA). The goal of the project is to develop, construct, and operate a wind power plant interconnected to a small isolated utility grid in an arctic climate in Northwest Alaska. The primary objective of KEA’s wind energy program is to bring more affordable electricity and jobs to remote Alaskan communities. DOE funding has allowed KEA to develop a multi-faceted approach to meet these objectives that includes wind project planning and development, technology transfer, and community outreach. The first wind turbines were installed in the summer of 1997 and the newest turbines were installed in the spring of 2007. The total installed capacity of the KEA wind power project is 1.16 MW with a total of 17 turbines rated between 65 kW and 100 kW. The operation of the wind power plant has resulted in a wind penetration on the utility system in excess of 35% during periods of low loads. This document and referenced attachments are presented as the final technical report for the U.S. Department of Energy (DOE) grant agreement DE-FG36-97GO10199. Interim deliverables previously submitted are also referenced within this document and where reasonable to do so, specific sections are incorporated in the report or attached as appendices.

  8. Comparative efficiency of wind turbines with different heights of rotor hubs: performance evaluation for Latvia

    International Nuclear Information System (INIS)

    Bezrukovs, V P; Zacepins, A J; Bezrukovs, V V

    2014-01-01

    Performance evaluation of wind turbines (WT) for different heights of the rotor hub is made based on the wind speed and direction data obtained in 2009–2013 on-shore in the north of Latvia using a LOGGER 9200 Symphonie measurement system mounted on a 60 m mast. Based on the measurement analysis results, wind speed distribution curves have been modelled for heights of up to 200 m using power and logarithmic (log) law approximation methods. The curves for the modelled Weibull's parameters are plotted in dependence on height. The efficiency comparison is made for different WT types taking into account the distribution of the wind energy potential in height in the Latvian territory. The annual electric energy production was calculated for the WTs with different heights of rotor hubs. In the calculations the technical data on the following WT types were used: E-3120 (50 kW, hub height 20.5/30.5/36.5/42.7 m), E-33 (330 kW, hub height 37/44/49/50 m), E-48 (800 kW, hub height 50/60/75 m) and E-82 (2.3 MW, hub height of 78/85/98/108/138 m)

  9. Status report of wind energy programs in the Philippines

    Energy Technology Data Exchange (ETDEWEB)

    Benavidez, P.J. [National Power Corp., Quezon City (Philippines)

    1996-12-31

    This paper discusses the wind resource assessment activities being undertaken by the National Power Corporation at the extreme northern part of Luzon island. Preliminary results from the 10-month wind data are presented. This will give prospective wind developers all idea oil tile vast resources of wind energy available in the northern part of the country. This paper will also discuss briefly the stand-alone 10 kW wind turbine system that was commissioned early this year and the guidelines being drafted for the entry of new and renewable energy sources in the country`s energy generation mix. 4 figs., 1 tab.

  10. PV-wind hybrid system performance. A new approach and a case study

    International Nuclear Information System (INIS)

    Arribas, Luis; Cano, Luis; Cruz, Ignacio; Mata, Montserrat; Llobet, Ermen

    2010-01-01

    Until now, there is no internationally accepted guideline for the measurement, data exchange and analysis of PV-Wind Hybrid Systems. As there is a need for such a tool, so as to overcome the barrier that the lack of confidence due to the absence of reliability means for the development of the market of Hybrid Systems, an effort has been made to suggest one tool for PV-Wind Hybrid Systems. The suggested guidelines presented in this work are based on the existing guidelines for PV Systems, as a PV-Wind Hybrid system can be roughly thought of as a PV System to which wind generation has been added. So, the guidelines for PV Systems are valid for the PV-Wind System, and only the part referred to wind generation should be included. This has been the process followed in this work. The proposed method is applied to a case study, the CICLOPS Project, a 5 kW PV, 7.5 kW Wind Hybrid system installed at the Isolated Wind Systems Test Site that CIEMAT owns in CEDER (Soria, Spain). This system has been fully monitored through a year and the results of the monitoring activity, characterizing the long-term performance of the system are shown in this work. (author)

  11. PV-wind hybrid system performance. A new approach and a case study

    Energy Technology Data Exchange (ETDEWEB)

    Arribas, Luis; Cano, Luis; Cruz, Ignacio [Departamento de Energias Renovables, CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain); Mata, Montserrat; Llobet, Ermen [Ecotecnia, Roc Boronat 78, 08005 Barcelona (Spain)

    2010-01-15

    Until now, there is no internationally accepted guideline for the measurement, data exchange and analysis of PV-Wind Hybrid Systems. As there is a need for such a tool, so as to overcome the barrier that the lack of confidence due to the absence of reliability means for the development of the market of Hybrid Systems, an effort has been made to suggest one tool for PV-Wind Hybrid Systems. The suggested guidelines presented in this work are based on the existing guidelines for PV Systems, as a PV-Wind Hybrid system can be roughly thought of as a PV System to which wind generation has been added. So, the guidelines for PV Systems are valid for the PV-Wind System, and only the part referred to wind generation should be included. This has been the process followed in this work. The proposed method is applied to a case study, the CICLOPS Project, a 5 kW PV, 7.5 kW Wind Hybrid system installed at the Isolated Wind Systems Test Site that CIEMAT owns in CEDER (Soria, Spain). This system has been fully monitored through a year and the results of the monitoring activity, characterizing the long-term performance of the system are shown in this work. (author)

  12. Assessment of wind power generation along the coast of Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Adaramola, Muyiwa S., E-mail: muyiwa.adaramola@umb.no [Department of Ecology and Natural Resource Management, Norwegian University of Life Sciences, Ås (Norway); Agelin-Chaab, Martin [Department of Automotive, Mechanical and Manufacturing Engineering, University of Ontario Institute of Technology, Oshawa, ON (Canada); Paul, Samuel S. [REHAU Industries, Winnipeg, Manitoba (Canada)

    2014-01-15

    Highlights: • The wind energy and its economic viability along the coastal region of Ghana are examined. • Wind resource along the coastal region of Ghana fall into Class 2 or less wind resource. • Wind turbine with rated speed from 9 to 11 m/s is suggested for wind power development. • The unit cost of wind generated electricity is found be between 0.0732 GH¢/kW h and 0.2905 GH¢/kW h. - Abstract: This study examined the wind energy potential and the economic viability of using wind turbine for electricity generation in selected locations along the coastal region of Ghana. The two-parameter Weibull probability density function was employed to analyze the wind speed data obtained from the Ghana Energy Commission. The energy output and unit cost of electricity generated from medium size commercial wind turbine models with rated powers ranging from 50 kW to 250 kW were determined. It was found that the wind resource along the coastal region of Ghana can be classified into Class 2 or less wind resource which indicate that this resource in this area is marginally suitable for large scale wind energy development or suitable for small scale applications and be useful as part of hybrid energy system. It was further observed that wind turbine with designed cut-in wind speed of less than 3 m/s and moderate rated wind speed between 9 and 11 m/s is more suitable for wind energy development along the coastal region of Ghana. Based on the selected wind turbine and assumptions used in this study, it was estimated that the unit cost of electricity varied between 0.0695 GH¢/kW h and 0.2817 GH¢/kW h.

  13. Assessment of wind power generation along the coast of Ghana

    International Nuclear Information System (INIS)

    Adaramola, Muyiwa S.; Agelin-Chaab, Martin; Paul, Samuel S.

    2014-01-01

    Highlights: • The wind energy and its economic viability along the coastal region of Ghana are examined. • Wind resource along the coastal region of Ghana fall into Class 2 or less wind resource. • Wind turbine with rated speed from 9 to 11 m/s is suggested for wind power development. • The unit cost of wind generated electricity is found be between 0.0732 GH¢/kW h and 0.2905 GH¢/kW h. - Abstract: This study examined the wind energy potential and the economic viability of using wind turbine for electricity generation in selected locations along the coastal region of Ghana. The two-parameter Weibull probability density function was employed to analyze the wind speed data obtained from the Ghana Energy Commission. The energy output and unit cost of electricity generated from medium size commercial wind turbine models with rated powers ranging from 50 kW to 250 kW were determined. It was found that the wind resource along the coastal region of Ghana can be classified into Class 2 or less wind resource which indicate that this resource in this area is marginally suitable for large scale wind energy development or suitable for small scale applications and be useful as part of hybrid energy system. It was further observed that wind turbine with designed cut-in wind speed of less than 3 m/s and moderate rated wind speed between 9 and 11 m/s is more suitable for wind energy development along the coastal region of Ghana. Based on the selected wind turbine and assumptions used in this study, it was estimated that the unit cost of electricity varied between 0.0695 GH¢/kW h and 0.2817 GH¢/kW h

  14. The Feasibility of Wind and Solar Energy Application for Oil and Gas Offshore Platform

    International Nuclear Information System (INIS)

    Tiong, Y K; Zahari, M A; Wong, S F; Dol, S S

    2015-01-01

    Renewable energy is an energy which is freely available in nature such as winds and solar energy. It plays a critical role in greening the energy sector as these sources of energy produce little or no pollution to environment. This paper will focus on capability of renewable energy (wind and solar) in generating power for offshore application. Data of wind speeds and solar irradiation that are available around SHELL Sabah Water Platform for every 10 minutes, 24 hours a day, for a period of one year are provided by SHELL Sarawak Sdn. Bhd. The suitable wind turbine and photovoltaic panel that are able to give a high output and higher reliability during operation period are selected by using the tabulated data. The highest power output generated using single wind energy application is equal to 492 kW while for solar energy application is equal to 20 kW. Using the calculated data, the feasibility of renewable energy is then determined based on the platform energy demand. (paper)

  15. Renewable energy and sustainable communities: Alaska's wind generator experience.

    Science.gov (United States)

    Konkel, R Steven

    2013-01-01

    In 1984, the Alaska Department of Commerce and Economic Development (DCED) issued the State's first inventory/economic assessment of wind generators, documenting installed wind generator capacity and the economics of replacing diesel-fuel-generated electricity. Alaska's wind generation capacity had grown from hundreds of installed kilowatts to over 15.3 megawatts (MW) by January 2012. This article reviews data and conclusions presented in "Alaska's Wind Energy Systems; Inventory and Economic Assessment" (1). (Alaska Department of Commerce and Economic Development, S. Konkel, 1984). It provides a foundation and baseline for understanding the development of this renewable energy source. Today's technologies have evolved at an astonishing pace; a typical generator in an Alaska wind farm now is likely rated at 1.5-MW capacity, compared to the single-kilowatt (kW) machines present in 1984. Installed capacity has mushroomed, illustrated by Unalakleet's 600-kW wind farm dwarfing the original three 10-kW machines included in the 1984 inventory. Kodiak Electric had three 1.5-MW turbines installed at Pillar Mountain in 2009, with three additional turbines of 4.5-MW capacity installed in 2012. Utilities now actively plan for wind generation and compete for state funding. State of Alaska energy policy provides the context for energy project decision-making. Substantial renewable energy fund (REF) awards--$202,000,000 to date for 227 REF projects in the first 5 cycles of funding--along with numerous energy conservation programs--are now in place. Increasing investment in wind is driven by multiple factors. Stakeholders have interests both in public policy and meeting private investment objectives. Wind generator investors should consider project economics and potential impacts of energy decisions on human health. Specifically this article considers: changing environmental conditions in remote Alaska villages, impacts associated with climate change on human health, progress in

  16. Canadian wind energy program

    Energy Technology Data Exchange (ETDEWEB)

    Templin, R J; South, P

    1976-01-01

    Several aspects of recent work at the National Research Council of Canada on the development of vertical-axis turbines have been reviewed. Most of this work, during the past year or more, has been in support of the design of a 200 kW unit now being built for experimental operation on the Magdelen Islands in the Gulf of St. Lawrence. Results of small and large scale aeroelastic wind tunnel model experiments have confirmed that very large scale vertical-axis wind turbines are feasible, especially if designed for normal operation at constant rotational speed. A computer model of a simple mixed power system has indicated that substantial cost savings may be possible by using wind energy in Canadian east coast regions. 4 refs., 11 figs., 1 tab.

  17. Design and construction of a simple blade pitch measurement system for small wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Whale, Jonathan [Research Institute of Sustainable Energy, Murdoch University, Perth, WA 6150 (Australia)

    2009-02-15

    For small wind turbines to be reliable they must have in place good mechanisms to protect themselves against very high winds or sudden removal of load. One common protection method in small wind turbines is that of blade feathering. It is important that the blade feathering mechanism of a small wind turbine is tested before the turbine is installed in the field. This paper presents a simple system for monitoring the blade feathering of a turbine with an overall component cost that small wind turbine manufacturers can afford. The Blade Pitch Measurement System (BPMS) has been designed and constructed by the Research Institute of Sustainable Energy (RISE) and aids small wind turbine manufacturers in testing and optimising the settings of the blade feathering mechanisms on their machines. The results show that the BPMS was successful in recording the behaviour of the blade feathering mechanism in field trials with a 20 kW and a 30 kW wind turbine. The BPMS displays significant potential as an effective, inexpensive system for small wind turbine manufacturers to ensure the reliability of their pitch regulating over-speed protection mechanisms. (author)

  18. Use of wind energy

    Energy Technology Data Exchange (ETDEWEB)

    Vasil' yeva, I G

    1982-01-01

    Programs on the use of wind energy have been adopted in over 12 countries. The WU of low power is manufactured by over 100 firms. One of the main trends for the use of wind energy currently is water pumping. The cost of operating water pumps with diesel and electric drive has increased and they have become not very accessible for a considerable part of the population in the developing countries. There are now about one million wind pump units (WPU) operating in the world, mainly in the United States, Australia and Argentina. The average power of the WPU is less than or equal to 0.5 kW. A trend is developing wind energy associated with the creation of wind heat units for heat supply of houses. When powerful experimental WEU are operating, the problem was revealed of their influence on the environment. The main difficulties are associated with creating WEU of electromagnetic interference, which in particular, influence the quality of television transmissions. This problem was encountered in operating the WEU P = 200 kW in the United States in Rhode Island. Normal operation of the television receivers was guaranteed with the help of cable network. A method was developed from calculating the zone of interferences which should be used in the future in setting up the WEU. A study was made of the noise from the operating of the WEU. The noise level of the WEU is in limits of permissible, however in direct proximity to the unit, intensive infrasonic fluctuations develop. The most important ecological consequence of building powerful WEU could be the death of nocturnal birds as a result of their colliding with the rotating blades. It is noted that this can be avoided by lighting the WEU.

  19. Wind power barometer

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The global wind power market not only repelled the strictures of the financial crisis, but saw the installation of 37 GW in 2009, which is almost 10 GW up on 2008. China and the United States registered particularly steady growth and the European Union also picked up momentum to break its installation record. A total capacity of 158 GW of wind power are now installed across the world from which 74.8 GW in the European Union. Among the European countries Denmark has the highest wind capacity per inhabitant in 2009: 627.5 kW/1000 inhabitants. Spain seeks to limit its market's growth in order to better manage the development of wind energy across the country. German growth is back, Italy chalks up a new record for installation and the French market is becoming increasingly regulated. United-Kingdom is developing offshore wind farms: the offshore capacity could reasonably rise to 20000 MW by 2020. The last part of the article reports some economical news from the leading players: Vestas, GE-Energy, Gamesa, Enercon, Sinovel and Siemens. (A.C.)

  20. Megawatt wind turbines gaining momentum

    International Nuclear Information System (INIS)

    Oehlenschlaeger, K.; Madsen, B.T.

    1996-01-01

    Through the short history of the modern wind turbine, electric utilities have made it amply clear that they have held a preference for large scale wind turbines over smaller ones, which is why wind turbine builders through the years have made numerous attempts develop such machines - machines that would meet the technical, aesthetic and economic demands that a customer would require. Considerable effort was put into developing such wind turbines in the early 1980s. There was the U.S. Department of Energy's MOD 1-5 program, which ranged up to 3.2 MW, Denmark's Nibe A and B, 630 kW turbine and the 2 MW Tjaereborg machine, Sweden's Naesudden, 3 MW, and Germany's Growian, 3 MW. Most of these were dismal failures, though some did show the potential of MW technology. (au)

  1. Radioactive Air Emissions Notice of Construction for the 105-KW Basin integrated water treatment system filter vessel sparging vent

    Energy Technology Data Exchange (ETDEWEB)

    Kamberg, L.D.

    1998-02-23

    This document serves as a notice of construction (NOC), pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060, and as a request for approval to construct, pursuant to 40 Code of Federal Regulations (CFR) 61.07, for the Integrated Water Treatment System (IWTS) Filter Vessel Sparging Vent at 105-KW Basin. Additionally, the following description, and references are provided as the notices of startup, pursuant to 40 CFR 61.09(a)(1) and (2) in accordance with Title 40 Code of Federal Regulations, Part 61, National Emission Standards for Hazardous Air Pollutants. The 105-K West Reactor and its associated spent nuclear fuel (SNF) storage basin were constructed in the early 1950s and are located on the Hanford Site in the 100-K Area about 1,400 feet from the Columbia River. The 105-KW Basin contains 964 Metric Tons of SNF stored under water in approximately 3,800 closed canisters. This SNF has been stored for varying periods of time ranging from 8 to 17 years. The 105-KW Basin is constructed of concrete with an epoxy coating and contains approximately 1.3 million gallons of water with an asphaltic membrane beneath the pool. The IWTS, which has been described in the Radioactive Air Emissions NOC for Fuel Removal for 105-KW Basin (DOE/RL-97-28 and page changes per US Department of Energy, Richland Operations Office letter 97-EAP-814) will be used to remove radionuclides from the basin water during fuel removal operations. The purpose of the modification described herein is to provide operational flexibility for the IWTS at the 105-KW basin. The proposed modification is scheduled to begin in calendar year 1998.

  2. Marketing research with respect to centralized electric power generation with wind turbines. Verkenning van de markt voor centrale elektriciteitsopwekking met windenergie

    Energy Technology Data Exchange (ETDEWEB)

    Lenstra, W.J.; Van den Doel, J.C.

    1985-01-01

    The electric utilities so far are not eager to invest in wind power as long as the price per kWh wind power is higher than saved fuel costs. The price the electric utilities are willing to pay for surplus wind power still remains low. Combined with price expectations in the near future for fossil fuels the market does not show great prospects. Wind turbine manufacturers were asked about price-quantity curves of wind turbine types: 3 MW, 1 MW, and 300 kW respectively. Combining the demand and supply side of the market it seems possible in areas having a good wind regime to exploit wind power in a cost-effective way. For a market incentive a wind power capacity of 400 MW: 75-3 MW wind turbines, 120-1 MW wind turbines, 15-300 kW wind turbines and 50 MW for demonstration projects for proving the viability of the technology. 3 figs., 2 tabs.

  3. FY 1998 Report on development of large-scale wind power generation systems. Feasibility study on development of new technologies for wind power generation (Study on the development of wind power generation); 1998 nendo ogata furyoku hatsuden system kaihatsu. Furyoku hatsuden shingijutsu kaihatsu kanosei chosa (furyoku hatsuden gijutsu ni kansuru kaihatsu doko chosa)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This survey is designed to analyze, e.g., current status of large-scale wind power generation devices/system technologies and development trends worldwide, and to make predictions about future developments, in an effort to contribute to advancements in new technology for wind power generation systems in Japan. The international R and D cooperation programs promoted by IEA and EU have helped the participants produce a number of good results at lower costs. The European countries have developed the wind power generation industries in each area, promoted by the governmental subsidy policies, and are leading the world. The system is becoming larger, from around an average unit capacity of 250kW in the beginning of the 90's to 600kW now, reducing the cost by the scale merit. The improved computer capacity has made it possible to more easily analyze the complicated rotor aerodynamics, structural dynamics, wind characteristics and other factors related to wind power generation systems. The future R and D directions will include world standards for large-scale wind turbines, advancements in wind farm technologies, offshore wind power generation systems, advancement in design technologies, and new concepts for wind power turbine designs, e.g., floating wind turbine. (NEDO)

  4. PLC based development of control, monitoring and interlock for 100 kW, 45.6 MHz ICRH system

    International Nuclear Information System (INIS)

    Jadav, Hiralal; Joshi, Rameshkumar; Mali, Aniruddh K.; Kadia; Bhavesh; Parmar; Maganbhai, Kiritkumar; Kulkarni, S.V.

    2015-01-01

    This paper presents details of PLC based system development for 100KW at the rate 45.6 MHz. Presently in ICRH RF DAC (Data acquisition and control) system existing based on real time VME and linux operating system. The ICRH system consists of 1.5 MW RF generator operating at 22- 40MHz which is used for second harmonic heating and pre-ionization experiments on SST-1 Tokamak at 1.5T and 3T magnetic field operation respectively. The task of PLC system in RF ICRH is to control, monitoring and interlocks HVDC power supply signal. Voltage and current signal of 2 kW, 20 kW, tetrode for 100 kW RF tube electrode like Filament, Control grid, Plate, Screen grid, signal monitor and voltage set raised by PLC analog IO module. Acknowledgement of the HVDC supply Filament, Control grid, Plate, Screen grid power supply is monitor and interlocks by PLC Digital IO module to interlocks stop the RF pulse and off HV power supply. The RF pulse(shot) to trigger signal generator (5mw) RF power output feed to LPA then chain of 2 KW, 20 KW, 100 KW at the rate 45.6 MHz. The programming logic controller (PLC) software is written in ladder language for AH500 Delta make using ISP Soft 2.04 and GUI is in the table form to control and monitor the parameters. Communication of PLC to PC by ethernet LAN network. (author)

  5. Superconducting wind turbine generators

    International Nuclear Information System (INIS)

    Abrahamsen, A B; Seiler, E; Zirngibl, T; Andersen, N H; Mijatovic, N; Traeholt, C; Pedersen, N F; Oestergaard, J; Noergaard, P B

    2010-01-01

    We have examined the potential of 10 MW superconducting direct drive generators to enter the European offshore wind power market and estimated that the production of about 1200 superconducting turbines until 2030 would correspond to 10% of the EU offshore market. The expected properties of future offshore turbines of 8 and 10 MW have been determined from an up-scaling of an existing 5 MW turbine and the necessary properties of the superconducting drive train are discussed. We have found that the absence of the gear box is the main benefit and the reduced weight and size is secondary. However, the main challenge of the superconducting direct drive technology is to prove that the reliability is superior to the alternative drive trains based on gearboxes or permanent magnets. A strategy of successive testing of superconducting direct drive trains in real wind turbines of 10 kW, 100 kW, 1 MW and 10 MW is suggested to secure the accumulation of reliability experience. Finally, the quantities of high temperature superconducting tape needed for a 10 kW and an extreme high field 10 MW generator are found to be 7.5 km and 1500 km, respectively. A more realistic estimate is 200-300 km of tape per 10 MW generator and it is concluded that the present production capacity of coated conductors must be increased by a factor of 36 by 2020, resulting in a ten times lower price of the tape in order to reach a realistic price level for the superconducting drive train.

  6. Wind energy in the Mediterranean countries

    International Nuclear Information System (INIS)

    Gaudiosi, G.

    1992-01-01

    This paper reviews the main findings relative to the European Communities OPET (Organization for the Promotion of Energy Technology) June 1992 conference on the potential for small and medium size wind energy applications in the Mediterranean countries and gives a panoramic look at progress being made by these countries in the development and use of wind energy turbines. One system which appears to be promising is the Danish 100 kW 'Bonus' wind turbine (23 m rotor, 30 m tower height) which has seen successful applications at a seaside resort and at a remote radio station in terms of performance, environmental compatibility and public acceptance

  7. Assessing the economic wind power potential in Austria

    International Nuclear Information System (INIS)

    Gass, Viktoria; Schmidt, Johannes; Strauss, Franziska; Schmid, Erwin

    2013-01-01

    In the European Union, electricity production from wind energy is projected to increase by approximately 16% until 2020. The Austrian energy plan aims at increasing the currently installed wind power capacity from approximately 1 GW to 3 GW until 2020 including an additional capacity of 700 MW until 2015. The aim of this analysis is to assess economically viable wind turbine sites under current feed-in tariffs considering constraints imposed by infrastructure, the natural environment and ecological preservation zones in Austria. We analyze whether the policy target of installing an additional wind power capacity of 700 MW until 2015 is attainable under current legislation and developed a GIS based decision system for wind turbine site selection.Results show that the current feed-in tariff of 9.7 ct kW h −1 may trigger an additional installation of 3544 MW. The current feed-in tariff can therefore be considered too high as wind power deployment would exceed the target by far. Our results indicate that the targets may be attained more cost-effectively by applying a lower feed-in tariff of 9.1 ct kW h −1 . Thus, windfall profits at favorable sites and deadweight losses of policy intervention can be minimized while still guaranteeing the deployment of additional wind power capacities. - Highlight: ► Wind supply curves with high spatial resolution for whole Austria are derived. ► Current feed-in tariff higher than necessary to attain targets. ► Previous feed-in tariffs were too low to achieve targets. ► Current support scheme leads to high social welfare losses. ► Policy makers face high information asymmetry when setting feed-in tariffs.

  8. THE DETERMINATION OF THE BALLAST RESISTANCE USED FOR THE CONECTION TO AN EXPERIMENTAL STAND FOR THE STUDY OF THE HYDRO – WIND HYBRIYD POWER (CHHE

    Directory of Open Access Journals (Sweden)

    JOIAN R.

    2015-09-01

    Full Text Available This paper point out some of the experimental determinations that must be made in the achieving of a hidro - wind hybrid system. It highlights the design and implementation of a1 kW ballast resistor and 48 V nickel-chromium wire, with the diameter of 60 three millimeters and connecting cable at the wind turbine by electric panel. Thus, this experimental stand CHHE includes a wind turbine 1 kW, placed on the roof of the Technical University of Cluj Napoca (this place is favorable because the wind has high speeds at great height and hydro turbine type Pelton 1 kW power. The experimental stand for the study of CHHE hybrid energy system will allow the determination of more experimental conclusive on the impact of the achievement of an energy balance of the physical model.

  9. Meteorological aspects of siting large wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hiester, T.R.; Pennell, W.T.

    1981-01-01

    This report, which focuses on the meteorological aspects of siting large wind turbines (turbines with a rated output exceeding 100 kW), has four main goals. The first is to outline the elements of a siting strategy that will identify the most favorable wind energy sites in a region and that will provide sufficient wind data to make responsible economic evaluations of the site wind resource possible. The second is to critique and summarize siting techniques that were studied in the Department of Energy (DOE) Wind Energy Program. The third goal is to educate utility technical personnel, engineering consultants, and meteorological consultants (who may have not yet undertaken wind energy consulting) on meteorological phenomena relevant to wind turbine siting in order to enhance dialogues between these groups. The fourth goal is to minimize the chances of failure of early siting programs due to insufficient understanding of wind behavior.

  10. New airfoils for small horizontal axis wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Giguere, P.; Selig, M.S. [Univ. of Illinois, Urbana, IL (United States)

    1997-12-31

    In a continuing effort to enhance the performance of small energy systems, one root airfoil and three primary airfoils were specifically designed for small horizontal axis wind turbines. These airfoils are intended primarily for 1-10 kW variable-speed wind turbines for both conventional (tapered/twisted) or pultruded blades. The four airfoils were wind-tunnel tested at Reynolds numbers between 100,000 and 500,000. Tests with simulated leading-edge roughness were also conducted. The results indicate that small variable-speed wind turbines should benefit from the use of the new airfoils which provide enhanced lift-to-drag ratio performance as compared with previously existing airfoils.

  11. Description and evaluation of foreign wind turbine technology

    International Nuclear Information System (INIS)

    1995-06-01

    It is stated that sales of Danish-manufactured wind turbines abroad are decreasing due to an increase in production, marketing and technology research in other countries. The aim was to give an account of this international development which could form the basis for the future strategies of the Danish Wind turbine industry. The study is based on a survey of relevant literature, interviews with experts on the subject and the collection of the latest data. The survey is limited to wind turbines with a larger capacity than 50 kW. Recommendations are given as to how to conserve and develop the market for Danish wind turbines. (AB) 17 refs

  12. Evaluation of wind turbine gearboxes; Evaluering af vindmoellegear

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-08-15

    A wind turbine's gearbox is the single component in which failures with risk of breakdown occur. The problems typically occur in the form of pitting damages in cogwheels and breakdown in bearings. The number of gearbox problems are increasing especially in 600 and 750 kW wind turbines. This project comprises a failure detection and analysis system, a gearbox calculation program, load monitoring, and finally dynamics of the mechanical transmission system. (BA)

  13. Vertical-axis wind turbine development in Canada

    Science.gov (United States)

    Templin, R. J.; Rangi, R. S.

    1983-12-01

    Recent Canadian progress in the development of the curved-blade Darrieus vertical-axis wind turbine (VAWT) is described. Cooperation between government, industry and power utilities in the conduct of field trials, over several years, has demonstrated improved performance and reliability of grid-coupled turbines of this type. The rated power of the VAWTs currently under test ranges from 30 kW, in a wind/diesel powerplant, to 230 kW, in an installation on an island in the Gulf of St. Lawrence. Progress has also been made in understanding the basic aerodynamic behavior of the VAWT and theoretical methods for performance and load prediction have correspondingly improved. A brief description is given of 'Project EOLE', a cooperative project between the federal government and the utility Hydro-Quebec to develop and test, during the next two to three years, a 4 MW VAWT prototype, which will be coupled to the power grid at a location on the south shore of the St. Lawrence River.

  14. Development of wind power generation in China

    International Nuclear Information System (INIS)

    Zhiquan, Y.; Yan, C.; Lijun, X.

    1995-01-01

    Present status and development of wind power generation in China is described in this paper. China is vast in territory with abundant wind resources. The exploitable wind energy in China is estimated up to 253,000 MW. At present, more than 150 thousand small WTGs of a total capacity of 17 MW are used to provide residential electricity uses in non-grid connected areas and 13 wind farms, with above 160 medium and large scale grid connected WTGs (50-500 kW) of a total capacity of 30 MW, have been constructed. At the same time, some progress has been made in the fields of nation-wide wind resource assessment, measurement technology of wind turbine performance, the assimilation of foreign wind turbine technology, grid connected WTG technology and the operation of wind farm etc. It is planned that the total installed capacity of WTGs will reach 1000 MW by the end of 2000. Wind power generation could be a part of electric power industry in China. (Author)

  15. Reduction of Background Noise in the NASA Ames 40- by 80-Foot Wind Tunnel

    Science.gov (United States)

    Jaeger, Stephen M.; Allen, Christopher S.; Soderman, Paul T.; Olson, Larry E. (Technical Monitor)

    1995-01-01

    Background noise in both open-jet and closed wind tunnels adversely affects the signal-to-noise ratio of acoustic measurements. To measure the noise of increasingly quieter aircraft models, the background noise will have to be reduced by physical means or through signal processing. In a closed wind tunnel, such as the NASA Ames 40- by 80- Foot Wind Tunnel, the principle background noise sources can be classified as: (1) fan drive noise; (2) microphone self-noise; (3) aerodynamically induced noise from test-dependent hardware such as model struts and junctions; and (4) noise from the test section walls and vane set. This paper describes the steps taken to minimize the influence of each of these background noise sources in the 40 x 80.

  16. Design, fabrication, and test of a composite material wind turbine rotor blade

    Science.gov (United States)

    Griffee, D. G., Jr.; Gustafson, R. E.; More, E. R.

    1977-01-01

    The aerodynamic design, structural design, fabrication, and structural testing is described for a 60 foot long filament wound, fiberglass/epoxy resin matrix wind turbine rotor blade for a 125 foot diameter, 100 kW wind energy conversion system. One blade was fabricated which met all aerodynamic shape requirements and was structurally capable of operating under all specified design conditions. The feasibility of filament winding large rotor blades was demonstrated.

  17. Design study of coated conductor direct drive wind turbine generator for small scale demonstration

    DEFF Research Database (Denmark)

    Abrahamsen, Asger Bech; Jensen, Bogi Bech

    2012-01-01

    We have investigated the properties of a superconducting direct drive generator suitable for demonstration in a small scale 11 kW wind turbine. The engineering current density of the superconducting field windings is based on properties of coated conductors wound into coils holding of the order 68...

  18. Renewable energy and sustainable communities: Alaska's wind generator experience†

    Science.gov (United States)

    Konkel, R. Steven

    2013-01-01

    Background In 1984, the Alaska Department of Commerce and Economic Development (DCED) issued the State's first inventory/economic assessment of wind generators, documenting installed wind generator capacity and the economics of replacing diesel-fuel-generated electricity. Alaska's wind generation capacity had grown from hundreds of installed kilowatts to over 15.3 megawatts (MW) by January 2012. Method This article reviews data and conclusions presented in “Alaska's Wind Energy Systems; Inventory and Economic Assessment” (1). (Alaska Department of Commerce and Economic Development, S. Konkel, 1984). It provides a foundation and baseline for understanding the development of this renewable energy source. Results Today's technologies have evolved at an astonishing pace; a typical generator in an Alaska wind farm now is likely rated at 1.5-MW capacity, compared to the single-kilowatt (kW) machines present in 1984. Installed capacity has mushroomed, illustrated by Unalakleet's 600-kW wind farm dwarfing the original three 10-kW machines included in the 1984 inventory. Kodiak Electric had three 1.5-MW turbines installed at Pillar Mountain in 2009, with three additional turbines of 4.5-MW capacity installed in 2012. Utilities now actively plan for wind generation and compete for state funding. Discussion State of Alaska energy policy provides the context for energy project decision-making. Substantial renewable energy fund (REF) awards – $202,000,000 to date for 227 REF projects in the first 5 cycles of funding – along with numerous energy conservation programs – are now in place. Increasing investment in wind is driven by multiple factors. Stakeholders have interests both in public policy and meeting private investment objectives. Wind generator investors should consider project economics and potential impacts of energy decisions on human health. Specifically this article considers:changing environmental conditions in remote Alaska villages,impacts associated

  19. Renewable energy and sustainable communities: Alaska's wind generator experience†

    Directory of Open Access Journals (Sweden)

    R. Steven Konkel

    2013-08-01

    Full Text Available Background . In 1984, the Alaska Department of Commerce and Economic Development (DCED issued the State's first inventory/economic assessment of wind generators, documenting installed wind generator capacity and the economics of replacing diesel-fuel-generated electricity. Alaska's wind generation capacity had grown from hundreds of installed kilowatts to over 15.3 megawatts (MW by January 2012. Method . This article reviews data and conclusions presented in “Alaska's Wind Energy Systems; Inventory and Economic Assessment” (1. (Alaska Department of Commerce and Economic Development, S. Konkel, 1984. It provides a foundation and baseline for understanding the development of this renewable energy source. Results . Today's technologies have evolved at an astonishing pace; a typical generator in an Alaska wind farm now is likely rated at 1.5-MW capacity, compared to the single-kilowatt (kW machines present in 1984. Installed capacity has mushroomed, illustrated by Unalakleet's 600-kW wind farm dwarfing the original three 10-kW machines included in the 1984 inventory. Kodiak Electric had three 1.5-MW turbines installed at Pillar Mountain in 2009, with three additional turbines of 4.5-MW capacity installed in 2012. Utilities now actively plan for wind generation and compete for state funding. Discussion . State of Alaska energy policy provides the context for energy project decision-making. Substantial renewable energy fund (REF awards – $202,000,000 to date for 227 REF projects in the first 5 cycles of funding – along with numerous energy conservation programs – are now in place. Increasing investment in wind is driven by multiple factors. Stakeholders have interests both in public policy and meeting private investment objectives. Wind generator investors should consider project economics and potential impacts of energy decisions on human health. Specifically this article considers: a. changing environmental conditions in remote Alaska

  20. Wind Energy Conference, Boulder, Colo., April 9-11, 1980, Technical Papers

    Science.gov (United States)

    1980-03-01

    Papers are presented concerning the technology, and economics of wind energy conversion systems. Specific topics include the aerodynamic analysis of the Darrieus rotor, the numerical calculation of the flow near horizontal-axis wind turbine rotors, the calculation of dynamic wind turbine rotor loads, markets for wind energy systems, an oscillating-wing windmill, wind tunnel tests of wind rotors, wind turbine generator wakes, the application of a multi-speed electrical generator to wind turbines, the feasibility of wind-powered systems for dairy farms, and wind characteristics over uniform and complex terrain. Attention is also given to performance tests of the DOE/NASA MOD-1 2000-kW wind turbine generator, the assessment of utility-related test data, offshore wind energy conversion systems, and the optimization of wind energy utilization economics through load management.

  1. Modelling and Analysis of Radial Flux Surface Mounted Direct-Driven PMSG in Small Scale Wind Turbine

    Directory of Open Access Journals (Sweden)

    Theint Zar Htet

    2017-11-01

    Full Text Available This paper presents the modelling and analysis of permanent magnet synchronous generator (PMSG which are used in direct driven small scale wind turbines. The 3 kW PM generator which is driven directly without gear system is analyzed by Ansoft Maxwell 2D RMxprt. The performance analysis of generator includes the cogging torque in two teeth, induced coil voltages under load, winding current under load, airgap flux density distribution and so on. The modelling analysis is based on the 2D finite element techniques. In an electrical machine, an accurate determination of the geometry parameters is a vital role. The proper performance results of 3kW PMSG in small scale wind turbine can be seen in this paper.

  2. FY1999 technological development of wind power generation systems for islands. Development of wind power generation systems in islands; 1999 nendo ritoyo furyoku hatsuden system nado gijutsu kaihatsu. Rito ni okeru furyoku hatsuden system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective of developing wind power generation systems that suit small to medium size islands in Japan, conceptual design was made on a 100-kW class wind mill to satisfy such requirements as no need of large heavy machines, and gust resisting performance. Investigations were performed on sites suitable for demonstration tests thereof. This paper reports the achievements in fiscal 1999. In investigating the site location feasibilities, which took small to medium size islands in Okinawa Prefecture as the discussion objects, environmental investigation, wind condition forecast and investigation, and system linkage investigation were carried out, whereas one point each in three islands were extracted as the promising sites. The system discussion and design called for wind velocity resistance of 80 m/s, system linkage percentage of 40% at maximum, power generation cost of 20 yen per kWh, design life of 20 years, constructability of requiring no large heavy machines, and operation mode of diesel hybrid use. Along with these specifications, conceptual design was performed on the system constituting elements, such as wind mill blades, generators, electric power control devices, and towers. In the blade aerodynamic test, wind tunnel tests were executed by using three types of blade wings. Sample blades were fabricated for the preparation of blade material tests. (NEDO)

  3. Recommendation for an European wind turbine safety standard

    Energy Technology Data Exchange (ETDEWEB)

    Hjuler Jensen, P.; Hauge Madsen, P.; Winther-Jensen, M.; Machielse, L.; Stam, W.; Einsfeld, V.; Woelfel, E.; Elliot, G.; Wilde, L. de

    1988-09-15

    The objective is to establish an European standard for wind safety which should apply for all member countries of the European Communities. The document contains a list of recommended safety requirements in relation to the system, structure, electrical installations, operation and maintenance of wind turbines. The recommended safety standards cover electricity producing wind turbines connected to electricity grids in both single and cluster applications and with a swept area in excess of 25 square meters and/or a rated power of 10kW. The document should be used in combination with The European Standards for Wind Turbine Loads and other relevant European Standards. Environmental condition, with the emphasis of wind conditions and more extreme climatic conditions, are also considered in relation to safety requirements. (AB).

  4. Measured performance of a 1.72 kW rooftop grid connected photovoltaic system in Ireland

    International Nuclear Information System (INIS)

    Ayompe, L.M.; Duffy, A.; McCormack, S.J.; Conlon, M.

    2011-01-01

    This paper presents results obtained from monitoring a 1.72 kW p photovoltaic system installed on a flat roof of a 12 m high building in Dublin, Ireland (latitude 53.4 o N and longitude 6.3 o E). The system was monitored between November 2008 and October 2009 and all the electricity generated was fed into the low voltage supply to the building. Monthly average daily and annual performance parameters of the PV system evaluated include: final yield, reference yield, array yield, system losses, array capture losses, cell temperature losses, PV module efficiency, system efficiency, inverter efficiency, performance ratio and capacity factor. The maximum solar radiation, ambient temperature and PV module temperature recorded were 1241 W/m 2 in March, 29.5 o C and 46.9 o C in June respectively. The annual total energy generated was 885.1 kW h/kW p while the annual average daily final yield, reference yield and array yield were 2.41 kW h/kW p /day, 2.85 kW h/kW p /day and 2.62 kW h/kW p /day respectively. The annual average daily PV module efficiency, system efficiency and inverter efficiency were 14.9%, 12.6% and 89.2% respectively while the annual average daily performance ratio and capacity factor were 81.5% and 10.1% respectively. The annual average daily system losses, capture losses and cell temperature losses were 0.23 h/day, 0.22 h/day and 0.00 h/day respectively. Comparison of this system with other systems in different locations showed that the system had the highest annual average daily PV module efficiency, system efficiency and performance ratio of 14.9%, 12.6% and 81.5% respectively. The PV system's annual average daily final yield of 2.4 kW h/kW p /day is higher than those reported in Germany, Poland and Northern Ireland. It is comparable to results from some parts of Spain but it is lower than the reported yields in most parts of Italy and Spain. Despite low insolation levels, high average wind speeds and low ambient temperature improve Ireland

  5. South Africa – a new innovator and manufacturer of wind turbines?

    CSIR Research Space (South Africa)

    Szewczuk, S

    2012-10-01

    Full Text Available South African innovation and ingenuity has resulted in a totally indigenous 300 kW wind turbine that has been designed and manufactured to withstand the rigours of the African continent....

  6. Evaluation of wind flow with a nacelle-mounted, continuous wave wind lidar

    DEFF Research Database (Denmark)

    Medley, John; Barker, Will; Harris, Mike

    2014-01-01

    Nacelle-mounted lidar is becoming widely recognized as a tool with potential for assessing power curves, understanding wind flow characteristics, and controlling turbines. As rotor diameters continue to increase, and the deployment of turbines in complex terrain becomes more widespread, knowledge...... mounted on the nacelle of a 550 kW turbine at the Risø campus of the Technical University of Denmark (DTU). Lidar measurements of wind speed and turbulence were compared against those made by anemometers on a high-quality traditional mast. Analysis showed excellent correlation between mast and Zeph...... that this is the first time that a commercially available nacelle-mounted lidar has been used to evaluate such rotor-equivalent power curves....

  7. The socio-economic costs of the planned development of wind power energy

    International Nuclear Information System (INIS)

    Bentzen, J.

    1992-01-01

    The socio-economic consequences of the Danish government's planned further development of wind power energy are discussed in detail. It is claimed that, currently, electricity produced by wind turbines is more expensive than that produced by power stations, if the relative environmental effects are not taken into consideration. It is expected that technological development will contribute to cost reduction by the year 2010 so that electricity produced by wind turbines will be competitive, but until then costs of wind power energy will be high and it is reckoned that losses will be in the range of 5-6 billion Danish crowns, minus 2.5 billion saved by lack of CO 2 emission. The socio-economic factors regarding windmills of various sizes (150 kW and 225 kW) are calculated and the planned development of wind power until 2010 is explained. The socio-economic costs of the development programme under various conditions, including the calculation of the saved emissions of carbon dioxide, are discussed. The author states that, in the light of these arguments, he is not in agreement with the governmental plan for the development of wind-turbine produced electricity. It is suggested that this plan could be postponed until such time as wind-power produced electricity should be more competitive in price, and that it should not be pursued during a period of economic recession. (AB)

  8. Development of 10kW SOFC module

    Energy Technology Data Exchange (ETDEWEB)

    Hisatome, N.; Nagata, K. [Mitsubishi Heavy Industries, Ltd., Nagasaki (Japan); Kakigami, S. [Electric Power Development Co., Inc., Tokyo (Japan)] [and others

    1996-12-31

    Mitsubishi Heavy industries, Ltd. (MHI) has been developing tubular type Solid Oxide Fuel Cells (SOFC) since 1984. A 1 kW module of SOFC has been continuously operated for 3,000 hours with 2 scheduled thermal cycles at Electric Power Development Co., Inc. (EPDC) Wakamatsu Power Station in 1993. We have obtained of 34% (HHV as H{sub 2}) module efficiency and deterioration rate of 2% Per 1,000 hours in this field test. As for next step, we have developed 10 kW module in 1995. The 10 kW module has been operated for 5,000 hours continuously. This module does not need heating support to maintain the operation temperature, and the module efficiency was 34% (HHV as H{sub 2}). On the other hand, we have started developing the technology of pressurized SOFC. In 1996, pressurized MW module has been tested at MHI Nagasaki Shipyard & Machinery, Works. We are now planning the development of pressurized 10 kW module.

  9. Wind energy potential in India

    International Nuclear Information System (INIS)

    Rangarajan, S.

    1995-01-01

    Though located in the tropics, India is endowed with substantial wind resources because of its unique geographical location which gets fully exposed to both the south-west and north-east monsoon winds. The westerly winds of the south-west monsoons provide bulk of the wind potential. Areas with mean annual wind speed exceeding 18 k mph and areas with mean annual power density greater than 140 W/m 2 have been identified using the wind data collected by the wind monitoring project funded by the Ministry of Non-conventional Energy Sources (MNES). Seasonal variations in wind speed at selected locations are discussed as also the frequency distribution of hourly wind speed. Annual capacity factors for 250 kW wind electric generators have been calculated for several typical locations. A good linear correlation has been found between mean annual wind speed and mean annual capacity factor. A method is described for assessing wind potential over an extended region where adequate data is available. It is shown that the combined wind energy potential over five selected areas of limited extent in Gujarat, Andhra Pradesh and Tamil Nadu alone amounts to 22,000 MW under the assumption of 20 per cent land availability for installing wind farms. For a higher percentage of land availability, the potential will be correspondingly higher. (author). 12 refs., 6 figs., 3 tabs

  10. Report on a wind power development field test project (detailed wind condition investigation) in the city of Choshi; Choshishi ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    This paper describes observation on the annual wind condition at the Yokka-ichibadai in the city of Choshi. The average wind velocities were 4.7 and 3.8 m/s at the ground height of 20 and 10 meters, respectively, not having reached the NEDO's criterion values 5.6 and 5.0 m/s. The annual wind direction emergence rate on the wind axis was 70%, meeting the criterion value of 60% or higher, and the wind direction is stable. The exponent for the vertical wind velocity distribution was 3.3, which is similar to that in the urban area. Disturbance in the wind condition was 0.18, meeting the criterion value of 0.30 or lower. The maximum momentary wind velocity was 31.9 m/s, which is well below the criterion of 60 m/s presenting no problem as a wind mill construction site. The wind energy density was 94 W/m{sup 2}, being only 63% of the criterion value, when all the azimuths were used as the object. The result of the investigation is that the average wind velocity is low and the wind energy density is also low. However, if the size of wind mill to be introduced is set to the class B (300 kW), it is possible to attain an annual operation rate of 58%, an annual energy acquisition amount of 515 MWh, and a facility utilization rate of 19.6%. If set to the class C (750 kW), an operation rate of 78%, an annual energy acquisition of 1296 MWh, and a facility utilization rate of 19.7% can be obtained, meeting the criterion value. (NEDO)

  11. Wind Power Potential at Abandoned Mines in Korea

    Science.gov (United States)

    jang, M.; Choi, Y.; Park, H.; Go, W.

    2013-12-01

    This study performed an assessment of wind power potential at abandoned mines in the Kangwon province by analyzing gross energy production, greenhouse gas emission reduction and economic effects estimated from a 600 kW wind turbine. Wind resources maps collected from the renewable energy data center in Korea Institute of Energy Research(KIER) were used to determine the average wind speed, temperature and atmospheric pressure at hub height(50 m) for each abandoned mine. RETScreen software developed by Natural Resources Canada(NRC) was utilized for the energy, emission and financial analyses of wind power systems. Based on the results from 5 representative mining sites, we could know that the average wind speed at hub height is the most critical factor for assessing the wind power potential. Finally, 47 abandoned mines that have the average wind speed faster than 6.5 m/s were analyzed, and top 10 mines were suggested as relatively favorable sites with high wind power potential in the Kangwon province.

  12. International wind energy development. World market update 2001. Forecast 2002-2006

    International Nuclear Information System (INIS)

    2002-03-01

    In the year 2001, the wind power development took another major step forward. Installed capacity set a new record with the addition of 6,824 MW of new generating capacity. This is 2,329 MW more than the record set in year 2000. Growth in new capacity is up from 15% in year 2000 to 52% in 2001. This confirmed that the trend of wind energy being the preferred technology over other technologies for new generating capacity is continuing. Europe is the leading region for wind power. Of the new capacity added in 2001, 4,527 MW was installed in Europe. Germany once more shows this country's potential as the single most active market with the installation of 2,627 MW in new capacity, nearly 1,000 MW more than in the previous year. Germany consolidated its position as the world's leading developer of wind energy. The market in the US is once again the second largest wind energy market ahead of Spain. The expiration of the PTC at the end of the year 2001 gave some rush in the installation at the end of the year. The Danish market is on a deroute and lost pace completely in a changed political climate which means that the development of windpower is slowing down. Denmark has a very high penetration of windpower. On the supplier side Vestas Wind Systems A/S maintained its position as being the world's largest manufacturer of wind turbines. Vestas Wind Systems is now followed by Enercon GmbH. Without counting the US market figures Vestas Wind Systems A/S and Enercon has become the very closed in terms of sold MW. In the 3rd place is the Danish company NEG Micon A/S. Newcomers in the Top Ten list are Mitsubishi (JP) and REpower (GE). The most significant technological trend in the market is the continuing upscaling of machines. From year 2001 the average size of WTGs is 915 kW (in 2000: 800kW). In the very near future there will be erected wind turbines mainly dedicated for the upcoming offshore market of 4.5-5.0 MW. On Offshore there is only 10 MW installed during the year 2001

  13. Room for wind. An investigation into the possibilities for the erection of large numbers of wind turbines. Ruimte voor wind. Een studie naar de plaatsingsmogelijkheden van grote aantallen windturbines

    Energy Technology Data Exchange (ETDEWEB)

    Arkesteijn, L; Van Huis, G; Reckman, E

    1987-01-01

    The Dutch government aims to realize a wind power capacity in The Netherlands of 1000 MW in the year 2000. Environmental impacts of the erection of a large number of 200 kW and 1 MW wind turbines are studied. Four siting models have been developed in which attention is paid to environmental and economic aspects, the possibilities to introduce the electric power into the national power grid and the availability and reliability of enough wind. Noise pollution and danger for birds are to be avoided. The choice between the construction of wind parks where a number of wind turbines is concentrated in a small area or a more dispersed construction is somewhat difficult if all relevant factors are to be taken into consideration. Without government's interference the target of 1000 MW in the year 2000 will probably not be attained. It is therefore desirable to practise an active energy policy in favor of wind energy, for which many ways are possible.

  14. The 1.5 MW wind turbine of tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    De Wolff, T.J.; Sondergaard, H. [Nordtank Energy Group, Richmond, VA (United States)

    1996-12-31

    The Danish company Nordtank is one of the pioneers within the wind turbine industry. Since 1981 Nordtank has installed worldwide more than 2300 wind turbine generators with a total name plate capacity that is exceeding 350 MW. This paper will describe two major wind turbine technology developments that Nordtank has accomplished during the last year: Site Optimization of Nordtank wind turbines: Nordtank has developed a flexible design concept for its WTGs in the 500/600 kW range, in order to offer the optimal WTG solution for any given site and wind regime. Nordtank`s 1.5 MW wind turbine: In September 1995, Nordtank was the first company to install a commercial 1.5 NM WTG. This paper will document the development process, the design as well as operations of the Nordtank 1.5 MW WTG.

  15. Development, construction and testing of a vertical axis 200 kW wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    1974-12-20

    It is proposed to design and develop a large vertical axis wind turbine that will generate economically 200 kilowatts of power at a wind speed of about 30 miles per hour. The scope of this proposal is to carry out studies, build, erect and test an electrical power generation plant that will feed into existing power grids. Preliminary technical studies indicate that the power of the turbine increases with the third power of the the wind speed. The rotor power loading should be as high as the prevailing winds allow; thus it would always be advisable to let the rotor run at as high an rpm as the economics will allow. For turbines up to about 100 ft in diameter, an extruded blade seems to be the best solution for economic rotor design. A 300 ft/s runaway tip speed seems to be acceptable as an rpm limit. Structurally, it is advantageous to increase the blade airfoil section to 18%. The proposed program has a very high probability of success in that each element of the total system involves a very low technical risk. The manufacturing methods rely on existing technology, and preliminary research indicates that readily available commercial materials can be used. There will be no involvement with highly stressed, fatigue-sensitive components. The total unit energy cost will be about fifty percent less for the proposed 90 ft. turbine than for the 15 ft. turbine produced for the National Research Council. 8 figs., 12 tabs.

  16. A 20-KW Wind Energy Conversion System (WECS) at the Marine Corps Air Station, Kaneohe, Hawaii.

    Science.gov (United States)

    1983-01-01

    of propellers and that vertical-axis wind turbines would be more efficient. Several turbines such as the Darrieus and gyro-mill, of this type are... wind turbines , wind systems siting, alternate energy systems, remote site power generation. 20 ABSTRACT (Con!,,u,. - r r... .. do I(3 lI - d #,d e...Corps Air Station (MCAS) Kaneohe Bay, Hawaii. The wind turbine generator chosen for the evaluation was a horizontal-axis-propeller- downwind rotor

  17. Organizational forms promoting wind power development. Organizational and legal evaluation, energy- and environmental analysis and socio-economic analysis of wind turbine location along railways

    International Nuclear Information System (INIS)

    1997-12-01

    Modernization of the train material and transition from diesel-driven to el-driven trains result in reduced air pollution in Denmark. The purpose of this study is to define, concretize and compare organizational forms for use of wind power as the 'green' electric power for train operation. An investment into an wind turbine array with 500 kW wind turbines in roughness class 2 would be repaid in 7.9 year period. Air pollution abatement together with improved socio-economic structure due to growing employment would be achieved. Several models of 'green' electrification of the national railways are given, both for state- and privately owned wind power plants. (EG)

  18. Wind power: cost effective generation for the 1990s

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, T [Vestas Wind Systems A/S (Denmark)

    1989-01-01

    Wind power plants have been installed all over the world, notably in California and Denmark. Commercially available wind turbines today are rated from 50 KW to 1 MW with emphasis on the 1 MW range. As the fuel is ''free'' generating costs are identical to the capital, operation and maintenance costs of the plant. An estimate of the unit price of wind power generated electricity in Denmark is comparable to that generated by a coal fired plant. The main environmental impacts of a wind farm are considered. These are visual impact, noise emission, use of (agricultural) space and the impact on wildlife, mainly birds. Finally the installation of a wind farm and its connection to the grid are described. (3 figures, 1 table). (UK)

  19. Starting-up sequence of the AWEC-60 wind turbine

    International Nuclear Information System (INIS)

    Avia, F.; Cruz, M. de la.

    1991-01-01

    One of the most critical status of the wind turbines operation is the starting-up sequence and the connection to the grid, due to the actuating loads that could be several times the loads during operation at rated conditions. Due to this fact, the control strategy is very important during the starting-up sequence in order to minimize the loads on the machine. For this purpose it is necessary to analyze the behaviour of the wind turbine during that sequence in different wind conditions and machine conditions. This report shows the graphic information about fifty starting-up sequences of the AWEC-60 wind turbine of 60 m. diameter and 1200 kW of rated power, recorded in April 1991 and cut-out wind speed. (author)

  20. Aero-acoustic Computations of Wind Turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Michelsen, Jess; Sørensen, Jens Nørkær

    2002-01-01

    A numerical algorithm for acoustic noise generation is extended to 3D flows. The approach involves two parts comprising a viscous incompressible flow part and an inviscid acoustic part. In order to simulate noise generated from a wind turbine, the incompressible and acoustic equations are written...... in polar coordinates. The developed algorithm is combined with a so-called actuator-line technique in which the loading is distributed along lines representing the blade forces. Computations are carried out for the 500kW Nordtank wind turbine equipped with three LM19 blades. ©2001 The American Institute...

  1. Characterization of wind velocities in the upstream induction zone of a wind turbine using scanning continuous-wave lidars

    DEFF Research Database (Denmark)

    Simley, Eric; Angelou, Nikolas; Mikkelsen, Torben Krogh

    2016-01-01

    As a wind turbine generates power, induced velocities, lower than the freestream velocity, will be present upstream of the turbine due to perturbation of the flow by the rotor. In this study, the upstream induction zone of a 225kW horizontal axis Vestas V27 wind turbine located at the Danish...... Technical University’s Risø campus is investigated using a scanning Light Detection and Ranging (lidar) system. Three short-range continuous-wave “WindScanner” lidars are positioned in the field around the V27 turbine allowing detection of all three components of the wind velocity vectors within...... the induction zone. The time-averaged mean wind speeds at different locations in the upstream induction zone are measured by scanning a horizontal plane at hub height and a vertical plane centered at the middle of the rotor extending roughly 1.5 rotor diameters (D) upstream of the rotor. Turbulence statistics...

  2. Outcomes of the DeepWind Conceptual Design

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Borg, Michael; Aagaard Madsen, Helge

    2015-01-01

    DeepWind has been presented as a novel floating offshore wind turbine concept with cost reduction potentials. Twelve international partners developed a Darrieus type floating turbine with new materials and technologies for deep-sea offshore environment. This paper summarizes results of the 5 MW...... the Deepwind floating 1 kW demonstrator. The 5 MW simulation results, loading and performance are compared to the OC3-NREL 5 MW wind turbine. Finally the paper elaborates the conceptual design on cost modelling....... DeepWind conceptual design. The concept was evaluated at the Hywind test site, described on its few components, in particular on the modified Troposkien blade shape and airfoil design. The feasibility of upscaling from 5 MW to 20 MW is discussed, taking into account the results from testing...

  3. Winds of change: First Nations in the supply chain

    International Nuclear Information System (INIS)

    Soulliere, Marc

    2011-01-01

    TWN Wind Power is a First Nations company which aims at providing First Nation communities with the opportunity to develop small wind power projects to produce energy without harming their environment. Through its work in energy production, the company creates jobs and revenues in addition to protecting First Nations against electricity rate increases. The objective of this paper is to present a successful wind turbine project. This Band school wind turbine project consisted of installing a 5 kW wind turbine at a school in Keremeos and educating students in renewable energies field. The project was planned to be completed in October 2011. In addition to this project, TWN Wind Power has also completed other projects in Oklahoma, South Dakota, British Columbia, Nova Scotia and Saskatchewan successfully. This presentation highlighted the work carried out by TWN Wind Power to develop wind energy projects within First Nations communities.

  4. Winds of change: First Nations in the supply chain

    Energy Technology Data Exchange (ETDEWEB)

    Soulliere, Marc [TWN Wind Power Inc. (Canada)

    2011-07-01

    TWN Wind Power is a First Nations company which aims at providing First Nation communities with the opportunity to develop small wind power projects to produce energy without harming their environment. Through its work in energy production, the company creates jobs and revenues in addition to protecting First Nations against electricity rate increases. The objective of this paper is to present a successful wind turbine project. This Band school wind turbine project consisted of installing a 5 kW wind turbine at a school in Keremeos and educating students in renewable energies field. The project was planned to be completed in October 2011. In addition to this project, TWN Wind Power has also completed other projects in Oklahoma, South Dakota, British Columbia, Nova Scotia and Saskatchewan successfully. This presentation highlighted the work carried out by TWN Wind Power to develop wind energy projects within First Nations communities.

  5. Lightning protection for wind turbines in Vietnam

    Directory of Open Access Journals (Sweden)

    Thuan Nguyen

    2017-01-01

    Full Text Available Wind energy has become increasingly important in the total electrical energy supply mix in Vietnam over the last few years. Small, kW turbines were installed in isolated areas a decade ago, while wind farms of several MW to few hundred MW are now being connected directly to national grid, with many additional projects in planning or under construction to fulfill an objective of 6% of the total installed capacity by 2030 (approximately 6200 MW of wind energy component. The increase in wind farm generation results in increased damage from lightning. In this paper, the annual frequency of lightning strikes to wind turbines in Vietnam is calculated using electrogeometric model. Reported lightning incidents to three major wind farms in Vietnam are summarized. Possible causes of failure are discussed, and an EMTP simulation for each incident was performed accordingly. The simulations suggest the failure mechanisms as well the potential of improved grounding to reduce lightning induced damage in future windfarms.

  6. The role of energy storage in accessing remote wind resources in the Midwest

    International Nuclear Information System (INIS)

    Lamy, Julian; Azevedo, Inês L.; Jaramillo, Paulina

    2014-01-01

    Replacing current generation with wind energy would help reduce the emissions associated with fossil fuel electricity generation. However, integrating wind into the electricity grid is not without cost. Wind power output is highly variable and average capacity factors from wind farms are often much lower than conventional generators. Further, the best wind resources with highest capacity factors are often located far away from load centers and accessing them therefore requires transmission investments. Energy storage capacity could be an alternative to some of the required transmission investment, thereby reducing capital costs for accessing remote wind farms. This work focuses on the trade-offs between energy storage and transmission. In a case study of a 200 MW wind farm in North Dakota to deliver power to Illinois, we estimate the size of transmission and energy storage capacity that yields the lowest average cost of generating and delivering electricity ($/MW h) from this farm. We find that transmission costs must be at least $600/MW-km and energy storage must cost at most $100/kW h in order for this application of energy storage to be economical. - Highlights: • We evaluate the break-even cost of energy storage to replace transmission. • We focus on a wind farm in North Dakota that must deliver power to Illinois. • Energy storage capital costs must be less than $100/kW h. • Transmission capital costs must be greater than $600/MW-km

  7. Design and implementation of a 38 kW dish-Stirling concentrated solar power system

    Science.gov (United States)

    Yan, J.; Peng, Y. D.; Cheng, Z. R.; Liu, F. M.; Tang, X. H.

    2017-11-01

    Dish-Stirling concentrated solar power system (DS-CSP) is an important pathway for converting solar energy into electricity at high efficiency. In this study, a rated power 38 kW DS-CSP system was developed (installed in Xiangtan Electric Manufacturing Group). The heat engine adopted the alpha-type four cylinders double-acting Stirling engine (Stirling Biopower Flexgen S260). The absorber flux distribution simulation was conducted using ray tracing method and then the 204 m2 parabolic dish concentrator system (diameter is 17.70 m and focal length is 9.49 m) with single concentrator plus single pillar supporting has been designed and built. A water-cooled disc target and an absorber imitation device were adopted to test the tracking performance of the dish concentrator system, homogeneity of the focal spot and flux distribution of the absorber. Finally, the S260 Stirling engine was installed on the focal position of the dish concentrator and then the net output power date of the 38 kW DS-CSP system was tested. The absorber overheating problem on the DS-CSP system performance was discussed when the DS-CSP system was installed in different locations. The testing result shows that this system achieved the net output power of 38 kW and solar-to-electricity efficiency (SEE) of 25.3% with the direct normal irradiation (DNI) at 750 W/m2. The net output power can further increase to 40.5 kW with the SEE of 26.6% when the DNI reaches up to the maximum of 761 W/m2. The net output power of the 38 kW DS-CSP system has a linear function relationship with the DNI. The fitting function is Net power output=0.1003×DNI-36.129, where DNI is at the range of 460∼761 W/m2. This function could be used to predict the amount of the 38 kW DS-CSP system annual generation power.

  8. Day-ahead wind speed forecasting using f-ARIMA models

    International Nuclear Information System (INIS)

    Kavasseri, Rajesh G.; Seetharaman, Krithika

    2009-01-01

    With the integration of wind energy into electricity grids, it is becoming increasingly important to obtain accurate wind speed/power forecasts. Accurate wind speed forecasts are necessary to schedule dispatchable generation and tariffs in the day-ahead electricity market. This paper examines the use of fractional-ARIMA or f-ARIMA models to model, and forecast wind speeds on the day-ahead (24 h) and two-day-ahead (48 h) horizons. The models are applied to wind speed records obtained from four potential wind generation sites in North Dakota. The forecasted wind speeds are used in conjunction with the power curve of an operational (NEG MICON, 750 kW) turbine to obtain corresponding forecasts of wind power production. The forecast errors in wind speed/power are analyzed and compared with the persistence model. Results indicate that significant improvements in forecasting accuracy are obtained with the proposed models compared to the persistence method. (author)

  9. Aleutian Pribilof Islands Wind Energy Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Bruce A. Wright

    2012-03-27

    Under this project, the Aleutian Pribilof Islands Association (APIA) conducted wind feasibility studies for Adak, False Pass, Nikolski, Sand Point and St. George. The DOE funds were also be used to continue APIA's role as project coordinator, to expand the communication network quality between all participants and with other wind interest groups in the state and to provide continued education and training opportunities for regional participants. This DOE project began 09/01/2005. We completed the economic and technical feasibility studies for Adak. These were funded by the Alaska Energy Authority. Both wind and hydro appear to be viable renewable energy options for Adak. In False Pass the wind resource is generally good but the site has high turbulence. This would require special care with turbine selection and operations. False Pass may be more suitable for a tidal project. APIA is funded to complete a False Pass tidal feasibility study in 2012. Nikolski has superb potential for wind power development with Class 7 wind power density, moderate wind shear, bi-directional winds and low turbulence. APIA secured nearly $1M from the United States Department of Agriculture Rural Utilities Service Assistance to Rural Communities with Extremely High Energy Costs to install a 65kW wind turbine. The measured average power density and wind speed at Sand Point measured at 20m (66ft), are 424 W/m2 and 6.7 m/s (14.9 mph) respectively. Two 500kW Vestas turbines were installed and when fully integrated in 2012 are expected to provide a cost effective and clean source of electricity, reduce overall diesel fuel consumption estimated at 130,000 gallons/year and decrease air emissions associated with the consumption of diesel fuel. St. George Island has a Class 7 wind resource, which is superior for wind power development. The current strategy, led by Alaska Energy Authority, is to upgrade the St. George electrical distribution system and power plant. Avian studies in Nikolski

  10. Impact of Financing Instruments and Strategies on the Wind Power Production Costs: A Case of Lithuania

    Science.gov (United States)

    Bobinaite, V.; Konstantinaviciute, I.

    2018-04-01

    The paper aims at demonstrating the relevance of financing instruments, their terms and financing strategies in relation to the cost of wind power production and the ability of wind power plant (PP) to participate in the electricity market in Lithuania. The extended approach to the Levelized Cost of Energy (LCOE) is applied. The feature of the extended approach lies in considering the lifetime cost and revenue received from the support measures. The research results have substantiated the relevance of financing instruments, their terms and strategies in relation to their impact on the LCOE and competitiveness of wind PP. It has been found that financing of wind PP through the traditional financing instruments (simple shares and bank loans) makes use of venture capital and bonds coming even in the absence of any support. It has been estimated that strategies consisting of different proportions of hard and soft loans, bonds, own and venture capital result in the average LCOE of 5.1-5.7 EURct/kWh (2000 kW), when the expected electricity selling price is 5.4 EURct/kWh. The financing strategies with higher shares of equity could impact by around 6 % higher LCOE compared to the strategies encompassing higher shares of debt. However, seeking to motivate venture capitalists, bond holders or other new financiers entering the wind power sector, support measures (feed-in tariff or investment subsidy) are relevant in case of 250 kW wind PP. It has been estimated that under the unsupported financing strategies, the average LCOE of 250 kW wind PP will be 7.8-8.8 EURct/kWh, but it will reduce by around 50 % if feed-in tariff or 50 % investment subsidy is applied.

  11. Performance investigation of a wind turbine–solar photovoltaic panels–fuel cell hybrid system installed at İncek region – Ankara, Turkey

    International Nuclear Information System (INIS)

    Devrim, Yılser; Bilir, Levent

    2016-01-01

    Highlights: • A hybrid system with a wind turbine, photovoltaic panels and a fuel cell was studied. • 3 kW wind turbine, 17.97 m 2 photovoltaics, 1.2 kW fuel cell and 4.7 kW electrolyzer was used. • The system can meet the entire demand of a residential house in Ankara, Turkey. • Only exception is in November, when the energy lack can be compensated from the grid. - Abstract: Renewable energy use in the world increases year by year. However, in many cases it is not possible to cover the electrical energy need of even a single house using only one renewable energy resource due to its intermittent nature. At this point, hybrid systems are applied to overcome this problem. This study focuses on the combination of photovoltaic solar panels, a small scale wind turbine, an electrolyzer and a proton exchange membrane fuel cell hybrid system for electrical power generation for an average house of 150 m 2 located at İncek region of Ankara, Turkey. Solar and wind energies were used as primary sources and a proton exchange membrane fuel cell is used as the backup power. The hybrid system was modeled and the results indicate that the use of the selected wind turbine with a 3 kW capacity along with photovoltaic panels with 17.97 m 2 area is sufficient to provide the required 5 h operation of the electrolyzer, which in turn provides the necessary hydrogen and oxygen to the fuel cell. Since the daily energy needed by the investigated house was taken as 5 kW h, the fuel cell with a net power output of 1 kW supplies all electrical demand with its 5 h operation. The outcomes show that the hybrid system is capable to provide all electrical need of the house all year round, except November. The electrical energy production of the proposed system is considerably higher than the demand in many months and this surplus electricity can be used in order to support the cooling and heating system of the considered house.

  12. A 25kW fiber-coupled diode laser for pumping applications

    Science.gov (United States)

    Malchus, Joerg; Krause, Volker; Koesters, Arnd; Matthews, David G.

    2014-03-01

    In this paper we report the development of a new fiber-coupled diode laser for pumping applications capable of generating 25 kW with four wavelengths. The delivery fiber has 2.0 mm core diameter and 0.22 NA resulting in a Beam Parameter Product (BPP) of 220 mm mrad. To achieve the specifications mentioned above a novel beam transformation technique has been developed combining two high power laser stacks in one common module. After fast axis collimation and beam reformatting a beam with a BPP of 200 mm mrad x 40 mm mrad in the slow and fast-axis is generated. Based on this architecture a customer-specific pump laser with 25 kW optical output power has been developed, in which two modules are polarization multiplexed for each wavelength (980nm, 1020nm, 1040m and 1060nm). After slow-axis collimation these wavelengths are combined using dense wavelength coupling before focusing onto the fiber endface. This new laser is based on a turn-key platform, allowing straight-forward integration into any pump application. The complete system has a footprint of less than 1.4m² and a height of less than 1.8m. The laser diodes are water cooled, achieve a wall-plug efficiency of up to 60%, and have a proven lifetime of <30,000 hours. The new beam transformation techniques open up prospects for the development of pump sources with more than 100kW of optical output power.

  13. Site-optimization of wind turbine generators

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, T.J. de; Thillerup, J. [Nordtank Energy Group, Richmond, VA (United States)

    1997-12-31

    The Danish Company Nordtank is one of the pioneers within the wind turbine industry. Since 1981 Nordtank has installed worldwide more than 2500 wind turbine generators with a total name plate capacity that is exceeding 450 MW. The opening up of new and widely divergent markets has demanded an extremely flexible approach towards wind turbine construction. The Nordtank product range has expanded considerable in recent years, with the main objective to develop wind energy conversion machines that can run profitable in any given case. This paper will describe site optimization of Nordtank wind turbines. Nordtank has developed a flexible design concept for its WTGs in the 500/750 kW range, in order to offer the optimal WTG solution for any given site and wind regime. Through this flexible design, the 500/750 turbine line can adjust the rotor diameter, tower height and many other components to optimally fit the turbine to each specific project. This design philosophy will be illustrated with some case histories of recently completed projects.

  14. Gearless wind power generator

    Energy Technology Data Exchange (ETDEWEB)

    Soederlund, L.; Ridanpaeae, P.; Vihriaelae, H.; Peraelae, R. [Tampere Univ. of Technology (Finland). Lab. of Electricity and Magnetism

    1998-10-01

    In the project a 100 kW axial flux permanent magnet wind power generator has been designed. The toroidal stator with air gap winding is placed between two rotating discs with permanent magnets. The magnet material is NdBFe due to its excellent magnetic properties compared to other materials. This type of topology enables a very large number of poles compared to conventional machine of the same size. A large number of poles is required to achieve a low rotational speed and consequently a direct driven system. The stator winding is formed by rectangular coils. The end winding is very short leading to small resistive losses. On the other hand, the absence of iron teeth causes eddy current losses in the conductors. These can be restricted to an acceptable level by keeping the wire diameter and flux density small. This means that the number of phases should be large. Several independent three phase systems may be used. The toothless stator also means that the iron losses are small and there exists no cogging torque

  15. Development of large scale wind energy conservation system. Development of control techniques for assembly-type wind power generating systems; Ogata furyoku hatsuden system no kaihatsu. Shugogata furyoku hatsuden system no seigyo gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Takita, M [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1994-12-01

    Described herein are the results of the FY1994 research program for development of control techniques for assembly-type wind power generating systems. The study on optimum system configuration produces 50 to 100kW wind power units for screening small-size wind power plant types, and, at the same time, surveys performance of commercial units and experiences of 9 makers capable of producing the above units. As a result, 3 MICON`s units (output: 100kW, active YAW control, monopole tower, maximum wind speed: 60m/s) are selected. The study on optimum operational techniques integrates 2 medium-size power units into a power line, showing a service factor of 30.2% on the annual average, monthly varying in a range from 11.8 to 45.0%. These units, installed in Miyako Island, were attacked by 3 typhoons of wind velocity of 25m/s or higher in 1994, and the only damage recorded is that of the anemoscope/anemometer. It is found that No.1 unit is located at a better geographical point than the No.2 unit, to produce a higher output. 3 figs., 3 tabs.

  16. A small wind power producer on a deregulated market

    International Nuclear Information System (INIS)

    Jari, Ihonen; Mikko, Jalas; Timo, Lahti

    2000-01-01

    Lumituuli Oy is a customer owned wind power producer in Finland. The company installed one wind turbine (Vestas V47/660kW) on an artificial island in Lumijoki in March 1999 and has sold electricity on the Finnish market since then. This document describes the experiences, which the company has gained in projecting the investment and operating of the turbine. A technical description of the special construction and erection technique, namely the ice road, is also included in this document. (author)

  17. The Lake Turkana wind farm project

    Energy Technology Data Exchange (ETDEWEB)

    Burlando, M.; Durante, F. [DEWI GmbH, Genoa (Italy); Claveri, L. [DEWI GmbH, Oldenburg (Germany)

    2010-08-15

    The Lake Turkana wind farm is one of the largest wind farm projects to be realised in the African Continent, and the first of its kind in Kenya. After its full commissioning in 2012, the wind farm will be generating 300 MW of clean power almost steadily thanks to the very peculiar characteristics of the wind climate of north-western Kenya. Until now, only northern African countries such as Morocco and Egypt had used wind power for commercial purposes on the continent. Projects are now beginning to bloom south of the Sahara as governments realise that harnessing the vast wind potential can efficiently meet the growing demand of electric power. With the Lake Turkana wind farm project and other minor projects, Kenya is trying to lead the way. The project consists of building 365 wind turbines Vestas V52 of hub height 45 m and nominal power 850 kW, corresponding to about 30% of Kenya's current installed power. The project includes also reinforcing 200 km of roads and bridges to transport the wind turbines from the Indian Ocean port of Mombasa to the northwestern Kenya, and adding more than 400 km of transmission lines and several substations to connect the wind farm and supply power to the national electric grid. (orig.)

  18. Assessment of wind turbine drive-train fatigue loads under torsional excitation

    DEFF Research Database (Denmark)

    Gallego Calderon, Juan Felipe; Natarajan, Anand

    2015-01-01

    allows the computation of the bearing and gear-mesh loads. The proposed models are validated by experiments from a 750 kW test-rig. The drive-train model is configured for a 5 MW power capacity and coupled to the corresponding wind turbine and load simulations are carried out under turbulent wind...... model is used in comparison to a simplified approach for load calculation. It is found that some of the wind turbine modes can have negative consequences on the life-time of the planetary bearings. © 2015 Elsevier Ltd. All rights reserved....

  19. Design and fabrication of a low-cost Darrieus vertical-axis wind-turbine system, phase 2. Volume 3: Design, fabrication, and site drawing

    Science.gov (United States)

    1983-03-01

    The design, fabrication, and site drawings associated with fabrication, installation, and check out of 100 kW 17 meter Vertical Axis Wind Turbines (VAWTs) were reported. The turbines are Darrieus type VAWTs with rotors 17 meters in diameter and 25.15 meters in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18 mph wind regime using 12% annualized costs. Four turbines are produced, three are installed and operable.

  20. Wind generator with electronic variable-speed drives

    Energy Technology Data Exchange (ETDEWEB)

    David, A.; Buchheit, N.; Jakobsen, H.

    1996-12-31

    Variable speed drives have been inserted between the network and the generator on certain recent wind power facilities. They have the following advantages: the drive allows the wind generator to operate at low speed with a significant reduction in acoustic noise, an important point if the facilities are sited near populated areas; the drive optimizes energy transfer, providing a gain of 4 to 10 %; the drive can possibly replace certain mechanical parts (the starting system and it in some cases, the reduction gear); the drive not only provides better transient management in relation to the network for less mechanical stress on the wind generator, it is also able to control reactive power. One commercial drive design sold by several manufacturers has already been installed on several wind generators with outputs of between 150 and 600 kw. In addition, such a solution is extremely well suited to mixed renewable energy systems. This design uses two inverse rectifier type converters and can therefore exchange energy in both directions. The equivalent drive with a single IGBT converter on the motor side and a diode converter on the network side is the solution most widely adopted throughout industry (with more than 50, 000 units installed in France per year). It still remains to be seen whether such a solution could be profitable in wind generator application (since the cost of the drive is quite high). This technical analysis is more destined for the converter-machine assembly specialists and is presented in this document, paying particular attention as it does to the modelling of the `wind energy - generator - drive - network` assembly, the associated drive command and control strategies and the simulations obtained during various transients. A 7.5 kW test bed has been installed in the Laboratoire d`Electronique de Puissance de Clamart, enabling tests to be carried out which emulate the operation of a wind generator.

  1. Experimental evaluation of wind turbines maximum power point tracking controllers

    International Nuclear Information System (INIS)

    Camblong, H.; Martinez de Alegria, I.; Rodriguez, M.; Abad, G.

    2006-01-01

    Wind energy technology has experienced important improvements this last decade. The transition from fixed speed to variable speed wind turbines has been a significant element of these improvements. It has allowed adapting the turbine rotational speed to the wind speed variations with the aim of optimizing the aerodynamic efficiency. A classic controller that has slow dynamics relative to the mechanical dynamics of the drive train is implemented in commercial wind turbines. The objective of the work related in this paper has been to evaluate the implementation, on a test bench, of a controller whose dynamics can be adjusted to be faster and to compare in particular its aerodynamic efficiency with the conventional controller. In theory, the higher dynamics of the non-classic controller has to lead to a better efficiency. A 180 kW wind turbine whose simulation model has been validated with field data is emulated on an 18 kW test bench. The emulator has also been validated. Test bench trials are a very useful step between numerical simulation and trials on the real system because they allow analyzing some phenomena that may not appear in simulations without endangering the real system. The trials on the test bench show that the non-conventional controller leads to a higher aerodynamic efficiency and that this is offset by higher mechanical torque and electric power fluctuations. Nevertheless, the amplitudes of these fluctuations are relatively low compared to their rated values

  2. Europe's largest solar thermal power plant. [200 kw thermal output supplemented by two 10-kw windmills

    Energy Technology Data Exchange (ETDEWEB)

    Bossel, U

    1976-03-01

    An overview is given over the solar heating plant which has recently been commissioned in the Camargue (France). This is the largest plant in Europe, with a mean heat output of about 200 kW, for the production of thermal energy from solar energy. The plant consists of 108 parabolic collectors (200 sq. metres) and 48 flat collectors (110 sq. metres). Two windmills with outputs of 10 kW each complete the system. The heat energy produced by the solar collectors is given up to 3 different stores, which in turn are connected to various consumers.

  3. A new generation of wind turbines; Une nouvelle generation d'eoliennes

    Energy Technology Data Exchange (ETDEWEB)

    Nica, H. [Tesnic, Laval, PQ (Canada)

    2008-06-15

    Although homeowners have expressed a desire to use wind energy to supply their electricity needs, many technical barriers have stood in the way of installing wind turbines in urban settings. This was due in part to three-bladed vertical axis turbines, high technical costs, limited performances in urban settings and questionable aesthetics. Tesnic has considered these issues and proposed a completely different turbine that uses a different method for extracting energy from the wind. The first approved 3.6 kW model should appear by the end of 2009. This new turbine is based on the same principal of the steam turbine patented in 1913 by Nikola Tesla. Instead of having blades, the Tesla turbine used closely spaced parallel disks and was recognized as being very robust with a high efficiency rating. Tesnic's new wind powered turbine is a vertical axis turbine with a series of valves that directs the wind on a rotor assembly of disk space. A series of blades on its circumference redirects the wind through the assembly of discs and accelerates the rotation of the rotor. The turbine extracts the wind energy in several ways, including conventional drag and lift, adherence and the vortex effect. This gives a 50 per cent added value of efficiency compared to other wind powered turbines. The global market for small wind powered energy is in full expansion. It has been projected that small turbines with 1 kW capacity will be abundant by 2020. It was noted that for household wind powered energy, the market must consider issues of cost, low maintenance, noise pollution, visual aesthetics, durability and safety. Wind energy can also be used in several industries, including plastics, composites, light metals, textiles and electronics. 2 figs.

  4. Influence of wind farm capacity, turbine size and wind speed on production cost: analysis of the actual market trend

    International Nuclear Information System (INIS)

    Laali, A.-R.; Meyer, J.-L.

    1996-01-01

    Several studies are undertaken in R and D Division of EDF in collaboration with ERASME association in order to have a good knowledge of the wind energy production costs. These studies are performed in the framework of a wind energy monitoring project and concern the influence of a few parameters like wind farm capacity, turbine size and wind speed on production costs, through an analysis of the actual market trend. Some 50 manufacturers and 140 different kind of wind turbines are considered for this study. The minimum production cost is situated at 800/900 kW wind turbine rated power. This point will probably move to more important powers in the future. This study is valid only for average conditions and some special parameters like particular climate conditions or lack of infrastructure for a special site that could modify the results shown on the curves. The variety of wind turbines (rated power as a function of rotor diameter, height and specific rated power) in the actual market is analysed. A brief analysis of the market trend is also performed. (author)

  5. Analysis of counter-rotating wind turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zakkam, Vinod Arun Kumar; Sørensen, Jens Nørkær

    2007-01-01

    This paper presents a study on the performance of a wind turbine with two counter-rotating (CRWT) rotors. The characteristics of the two counter-rotating rotors are on a 3-bladed Nordtank 500 kW rotor. The analysis has been carried out by using an Actuator Line technique implemented in the Navier......-Stokes code EllipSys3D. The analysis shows that the Annual Energy Production can be increased to about 43.5 %, as compared to a wind turbine with a single rotor. In order to determine the optimal settings of the CRWT turbine, parameters such as distance between two rotors and rotational speed have been...

  6. Wind energy generation for electric power production, preliminary studies. Part I

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, A

    1976-03-01

    Studies of wind power generation done by SAAB-Scania during 1975 are described. The project deals with generation of electricity for delivery to the transmission system. Both plants with horizontal axis and plants with vertical axis have been studied. A projected pilot plant with a rotor of 18 meter and an effect of 50 kW at 10 m/s wind velocity is described. Suggestions are made for a continuation of the project.

  7. Control Strategy: Wind Energy Powered Variable Chiller with Thermal Ice Storage

    Science.gov (United States)

    2014-12-01

    of the DOD facilities. A. RENEWABLE ENERGY The United States Department of Energy (DOE) defines renewable energy as being obtained from...include arrays of solar PV cells, solar thermal cells, wind turbines, or biogas digestors. Energy storage devices could consist of one or more of the...At Hachinohe, Japan, the Aomori Project obtains up to 100 kW of power from PV cells and wind turbines (WTs). The New Energy and Industrial Technology

  8. Trailing edge devices to improve performance and increase lifetime of wind-electric water pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [USDA-Agricultural Research Service, Bushland, TX (United States)

    1996-12-31

    Trailing edge flaps were applied to the blades of a 10 kW wind turbine used for water pumping to try to improve the performance and decrease the structural fatigue on the wind turbine. Most small wind turbines (10 kW and below) use furling (rotor turns out of wind similar to a mechanical windmill) to protect the wind turbine from overspeed during high winds. Some small wind turbines, however, do not furl soon enough to keep the wind turbine from being off line part of the time in moderately high wind speeds (10 - 16 m/s). As a result, the load is disconnected and no water is pumped at moderately high wind speeds. When the turbine is offline, the frequency increases rapidly often causing excessive vibration of the wind turbine and tower components. The furling wind speed could possibly be decreased by increasing the offset between the tower centerline and the rotor centerline, but would be a major and potentially expensive retrofit. Trailing edge flaps (TEF) were used as a quick inexpensive method to try to reduce the furling wind speed and increase the on time by reducing the rotor RPM. One TEF configuration improved the water pumping performance at moderately high wind speeds, but degraded the pumping performance at low wind speeds which resulted in little change in daily water volume. The other TEF configuration differed very little from the no flap configuration. Both TEF configurations however, reduced the rotor RPM in high wind conditions. The TEF, did not reduce the rotor RPM by lowering the furling wind speed as hoped, but apparently did so by increasing the drag which also reduced the volume of water pumped at the lower wind speeds. 6 refs., 9 figs.

  9. Status of the Southern California Edison Company 3 MW Wind Turbine Generator (WTG) demonstration project

    Science.gov (United States)

    Scheffler, R. L.

    1979-01-01

    To demonstrate the concept of utility scale electricity production from a high wind energy resource, a program was initiated to construct and test a 3 megawatt (3,000 kW) Schachle wind turbine generator near Palm Springs, California. The background and current status of this program are presented along with a summary of future planned program activities.

  10. Design and fabrication of a low cost Darrieus vertical axis wind turbine system: Phase 2, volume 1: Executive summary

    Science.gov (United States)

    1983-03-01

    Described is the successful fabrication, installation, and checkout of 100 kW 17 meter Vertical Axis Wind Turbines (VAWTs). The turbines are Darrieus-type VAWTs with rotors 17 meters (55 feet) in diameter and 25.15 meters (83 feet) in height. They can produce 100 kW of electric power at a cost of energy as low as 3 cents per kWh, in an 18 mph wind regime using 12% annualized costs. Four turbines were produced; three are installed and are operable at: (1) Wind Systems Test Center, Rocky Flats, Colorado; (2) the US Department of Agriculture Conservation and Production Research Center at Bushland, Texas; and (3) Tisbury Water Authority, Vineyard Haven, Massachusetts, on the island of Martha's Vineyard. The fourth turbine is stored at Bushland, Texas awaiting selection of an erection site.

  11. Development of a wind energy converter and investigation of its operational function. Part 4: Test setup and results of measurement

    Science.gov (United States)

    Armbrust, S.; Molly, J. P.

    1982-12-01

    Measurements made during test operations at the MODA.10 plant as well as at a 25 years old 6 kW wind energy converter are presented. The test arrangements, measurement results of both wind energy converters, and the experience gained are described.

  12. Full-Span Tiltrotor Aeroacoustic Model (TRAM) Overview and 40- by 80-Foot Wind Tunnel Test. [conducted in the 40- by 80-Foot Wind Tunnel at Ames Research Center

    Science.gov (United States)

    McCluer, Megan S.; Johnson, Jeffrey L.; Rutkowski, Michael (Technical Monitor)

    2001-01-01

    Most helicopter data trends cannot be extrapolated to tiltrotors because blade geometry and aerodynamic behavior, as well as rotor and fuselage interactions, are significantly different for tiltrotors. A tiltrotor model has been developed to investigate the aeromechanics of tiltrotors, to develop a comprehensive database for validating tiltrotor analyses, and to provide a research platform for supporting future tiltrotor designs. The Full-Span Tiltrotor Aeroacoustic Model (FS TRAM) is a dual-rotor, powered aircraft model with extensive instrumentation for measurement of structural and aerodynamic loads. This paper will present the Full-Span TRAM test capabilities and the first set of data obtained during a 40- by 80-Foot Wind Tunnel test conducted in late 2000 at NASA Ames Research Center. The Full-Span TRAM is a quarter-scale representation of the V-22 Osprey aircraft, and a heavily instrumented NASA and U.S. Army wind tunnel test stand. Rotor structural loads are monitored and recorded for safety-of-flight and for information on blade loads and dynamics. Left and right rotor balance and fuselage balance loads are monitored for safety-of-flight and for measurement of vehicle and rotor aerodynamic performance. Static pressure taps on the left wing are used to determine rotor/wing interactional effects and rotor blade dynamic pressures measure blade airloads. All of these measurement capabilities make the FS TRAM test stand a unique and valuable asset for validation of computational codes and to aid in future tiltrotor designs. The Full-Span TRAM was tested in the NASA Ames Research Center 40- by 80-Foot Wind Tunnel from October through December 2000. Rotor and vehicle performance measurements were acquired in addition to wing pressures, rotor acoustics, and Laser Light Sheet (LLS) flow visualization data. Hover, forward flight, and airframe (rotors off) aerodynamic runs were performed. Helicopter-mode data were acquired during angle of attack and thrust sweeps for

  13. Design study of 10 kW superconducting generator for wind turbine applications

    DEFF Research Database (Denmark)

    Abrahamsen, Asger Bech; Mijatovic, Nenad; Seiler, Eugen

    2009-01-01

    = 1 Tesla to be similar to the performance of permanent magnets and to represent a layout, which can be scaled up in future off-shore wind turbines. The proposed generator is a 8 pole synchronous machine based on race-track coils of high temperature superconducting tapes and an air cored copper stator...

  14. Wind energy statistics of Finland. Yearly report 2011; Tuulivoiman tuotantotilastot. Vuosiraportti 2011

    Energy Technology Data Exchange (ETDEWEB)

    Turkia, V.; Holttinen, H.

    2013-01-15

    Wind power production from grid connected wind turbines in Finland was 481 GWh in 2011. This corresponds to 0.6 % of Finland's electricity consumption. Installed wind capacity was 199 MW at the end of the year and the number of the operating turbines was 131. Two new turbines were installed in 2011 with the total power of 1.75 MW and no turbines were taken out of operation. The average size of all turbines in Finland was 1 519 kW at the end of 2011 (1519 kW at the end of 2010). The new climate and energy strategy has a target of 2 500 MW wind power in 2020. A market based feed-in system with a guaranteed price of 83.5 euro/MWh entered into force on 25 March 2011 in Finland. There will be an increased tariff of 105.3 euro/MWh until end of 2015 (max 3 years). The difference between the guaranteed price and spot price of electricity will be paid to the producers as a premium. Year 2010 had close to long term average wind resource. The weighted production index for the four sea areas was 98 %. Average capacity factor of standard wind turbines, which operated the whole year, was 24 % while the best turbine yielded 45 % capacity factor. Technical availability of the standard wind power plants was 88,5 % in 2011. This report contains production and availability figures of the grid connected wind turbines in Finland as well as component summary of failure statistics. There is an English list of figure and table captions and the yearly statistics table is as an appendix. (orig.)

  15. Noise measurements in 4 wind turbine farms

    International Nuclear Information System (INIS)

    Van Zuylen, E.J.; Koerts, M.

    1993-02-01

    The title wind turbine arrays are situated in Herbayum (Newinco 23PI250), Callantsoog (Bouma 160/20), Noordoostpolder (Windmaster WM300), and Ulketocht (Newinco 500 kW). Measurements were carried out by means of the so-called Ecofys Correlating Noise Meter to determine the source level of the wind turbines. The resulting source level as a function of the wind speed is interpolated to a source level for a wind speed of 8 m/s at 10 m height, on the basis of which the noise contours can be calculated. The noise contours are determined to analyze the noise load for people living in the neighbourhood of the wind parks. The source levels are compared with values as indicated in certificates, which are granted on the basis of a so-called Restricted Quality Certificate (BKC, abbreviated in Dutch) or the new standard NNI 6096/2 for the above-mentioned wind turbines. In general the results of this study agree quite well with the certified values. 12 figs., 7 tabs., 6 refs

  16. Power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell system with discrete ejector control

    Science.gov (United States)

    Nikiforow, K.; Pennanen, J.; Ihonen, J.; Uski, S.; Koski, P.

    2018-03-01

    The power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell (PEMFC) system are studied theoretically and experimentally for grid support service applications. The fuel supply is implemented with a fixed-geometry ejector and a discrete control solution without any anode-side pressure fluctuation suppression methods. We show that the stack power can be ramped up from 2.0 kW to 4.0 kW with adequate fuel supply and low anode pressure fluctuations within only 0.1 s. The air supply is implemented with a centrifugal blower. Air supply ramp rates are studied with a power increase executed within 1 and 0.2 s after the request, the time dictated by grid support service requirements in Finland and the UK. We show that a power ramp-up from 2.0 kW to 3.7 kW is achieved within 1 s with an initial air stoichiometry of 2.5 and within 0.2 s with an initial air stoichiometry of 7.0. We also show that the timing of the power ramp-up affects the achieved ancillary power capacity. This work demonstrates that hydrogen fueled and ejector-based PEMFC systems can provide a significant amount of power in less than 1 s and provide valuable ancillary power capacity for grid support services.

  17. Operational modal analysis on a VAWT in a large wind tunnel using stereo vision technique

    DEFF Research Database (Denmark)

    Najafi, Nadia; Schmidt Paulsen, Uwe

    2017-01-01

    This paper is about development and use of a research based stereo vision system for vibration and operational modal analysis on a parked, 1-kW, 3-bladed vertical axis wind turbine (VAWT), tested in a wind tunnel at high wind. Vibrations were explored experimentally by tracking small deflections...... of the markers on the structure with two cameras, and also numerically, to study structural vibrations in an overall objective to investigate challenges and to prove the capability of using stereo vision. Two high speed cameras provided displacement measurements at no wind speed interference. The displacement...

  18. The possible hindrance of a 10 MW wind farm along the Noordermeerdijk in the Noordoostpolder, Netherlands, for birds

    International Nuclear Information System (INIS)

    Van den Bergh, L.M.J.; Spaans, A.L.

    1993-01-01

    The title farm comprises 14 two-bladed 750 kW wind turbines. Hindrance of wind turbines are collisions with the wind turbines and in the wake behind the blades and loss or disintegration of the natural habitat because of the presence of the wind turbines (aspect of disturbance). The title study is focused on counting the number of collision bird victims per year, and analyzing the disturbance effects on hibernating and foraging birds. It appeared that almost 150 to more than 1500 birds will collide with one of the 16 wind turbines. A few hundred tufted ducks, some tens of pochard and some tens of wild ducks per kilometer of the array will leave their natural habitat. Based on the results it is concluded that the site south of the kilometre marker 7.0 is preferred to the site directly south of kilometre marker 5.0. It is also concluded that the above-mentioned array is preferred to a wind turbine array of 16 wind turbines of 500 kW each. The results of the investigation on that array are published in a separate report for which a separate abstract has been prepared. 2 figs., 6 tabs., 2 appendices, 34 refs

  19. System specifications for the fiscal 1995 NEDO wind power development field test project. Fukayama area, Nagashima-aza, Hiraizumi-cho, Nishiiwai-gun, Iwate Prefecture; 1995 nendo NEDO furyoku kaihatsu field test jigyo system sekkeisho. Iwateken Nishiiwaigun Hiraizumicho Nagashima aza Fukayama chinai

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This is system specifications for the wind power development field test project (NEDO). The system was designed setting the annual mean wind speed at 6m/s and the annual occurrence probability of wind speed of 4-6m/s at 12% or more. Considering the result of the high frequency power disturbance survey, the mountainside toward 70m west of the top of the Otowayama was planned for a site for the construction. Only one wind turbine is to be installed since the cost of land formation for the mountainside site becomes higher because of the distances between wind turbines required in the case of installing more than one wind turbine. The system interconnects with the Hiraizumi substation near by. The mean power generation amount per year by size of wind turbine was supposed to be 754, 1230, and 1467 MWh for 300, 500, and 600 kW classes, respectively. The budget raisable is 200 million yen, and operating expenses are 146, 203, and 228 million yen for each class mentioned above. The 500-600 kW class is high in economical efficiency and profitable now and in future. In the light of the license of chief electric engineer requested for the 600 kW class, selected was Mitsubishi Heavy Industries` MWT-500 Up-Wind type. Its specifications are: 3 GFRP blades, 32 rpm, 38m rotor diameter, 38m tower height, pitch control, and 490 kW. 49 figs., 53 tabs.

  20. Solar wind power electric plant on Vis (Croatia)

    International Nuclear Information System (INIS)

    1998-01-01

    A project of a solar photovoltaic electric power plant presented by the Republic of Croatia at the meeting of the E.P.I.A. Mission for photovoltaic technology of the Mediterranean countries, aroused a great interest of the representatives of the invited countries. However, the interest within Croatia in the project has disappeared although E.P.I.A. offered a financing of two thirds of costs. There are attempts to construct 1800 kw wind-driven generators at the same location not taking into consideration a possibility of building a hybrid solar-wind-power electric plant. The chance that the solar part is completely of domestic origin is not accepted but the preference is given to the building of imported wind-driven generators. (orig.)

  1. Permanent magnet machines with air gap windings and integrated teeth windings

    Energy Technology Data Exchange (ETDEWEB)

    Alatalo, M [Chalmers Univ. of Technology, Goeteborg (Sweden). School of Electrical and Computer Engineering

    1996-06-01

    The Thesis deals with axial and radial flux permanent magnet machines with air gap windings and an integrated teeth winding. The aim is to develop a machine that produces a high torque per unit volume with as low losses as possible. The hypothesis is that an advanced three-phase winding, magnetized by a permanent magnet rotor should be better than other machine topologies. The finite element method is used to find favourable dimensions of the slotless winding, the integrated teeth winding and the permanent magnet rotor. Three machines were built and tested in order to verify calculations. It can be concluded that the analysis method shows good agreement with the calculated and the measured values of induced voltage and torque. The experiments showed that the slotless machine with NdFeB-magnets performs approximately like the slotted machine. A theoretical comparison of axial flux topology to radial flux topology showed that the torque production of the inner rotor radial flux machine is superior to that of the axial flux machine. An integrated teeth winding based on iron powder teeth glued to the winding was studied. The force density of a pole with integrated teeth is around three times the force density of a slotless pole. A direct drive wind power generator of 6.4 kW with integrated teeth can have the same power losses and magnet weight as a transversal flux machine. Compared to a standard induction machine the integrated teeth machine had approximately 2.5 times the power capacity of the induction machine with the same power losses and outer volume. 39 refs

  2. THE SECOND KONUS- WIND CATALOG OF SHORT GAMMA-RAY BURSTS

    Energy Technology Data Exchange (ETDEWEB)

    Svinkin, D. S.; Frederiks, D. D.; Aptekar, R. L.; Golenetskii, S. V.; Pal' shin, V. D.; Oleynik, Ph. P.; Tsvetkova, A. E.; Ulanov, M. V. [Ioffe Institute, Politekhnicheskaya 26, St. Petersburg, 194021 (Russian Federation); Cline, T. L. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Hurley, K. [Space Sciences Laboratory, University of California, 7 Gauss Way, Berkeley, CA 94720-7450 (United States)

    2016-05-01

    In this catalog, we present the results of a systematic study of 295 short gamma-ray bursts (GRBs) detected by Konus- Wind (KW) from 1994 to 2010. From the temporal and spectral analyses of the sample, we provide the burst durations, the spectral lags, the results of spectral fits with three model functions, the total energy fluences, and the peak energy fluxes of the bursts. We discuss evidence found for an additional power-law spectral component and the presence of extended emission in a fraction of the KW short GRBs. Finally, we consider the results obtained in the context of the Type I (merger-origin)/Type II (collapsar-origin) classifications.

  3. Electric power generation in a combined photovoltaic and wind power system at Ottendorf-Okrilla (Saxony); Elektroenergieerzeugung einer kombinierten Wind-Photovoltaik-Anlage in Ottendorf-Okrilla (Sachsen)

    Energy Technology Data Exchange (ETDEWEB)

    Futterschneider, H.; Hirsch, W.; Rindelhardt, U.; Teichmann, G.

    1996-04-01

    A hybrid wind-photovoltaic system has been operated in the Zentrallager of the Plus-Warenhandelsgesellschaft in Ottendorf-Okrilla (Saxony) since 1992. A 60 kW wind energy converter of Tackes TW-60 type has been combined with a 3.18 kW photovoltaic system. Some special features of the pv system (orientation of the generator, master-slave operation of the inverters) are remarkable. The operation of both systems was investigated in detail. With a yield of 689 kWh/kW{sub p}a in 1995 the pv system achieved comparable results with other grid coupled pv systems in Saxony. Possible better results are prevented by the selected generator orientation. The master-slave mode of the inverter was studied in detail. The nonoptimal relation between the generator size and the inverters influenced the results. The wind energy converter achieved in 1995 a yield of 990 kWh/kW, which is below average also for non coast areas. The result is influenced by many obstacles in the surrounding of the converter. The time availability of the hybrid energy system in 1995 was 71.5% (6260 hours). (orig.) [Deutsch] Vom Zentrallager der Plus-Warenhandelgesellschaft in Ottendorf-Okrilla (Sachsen) wird seit 1992 eine hybride Wind-Photovoltaik-Anlage zur Erzeugung von Elektroenergie betrieben. Die Anlage besteht aus einer 60-kW-Windkraftanlage des Typs TW 60 und einer Photovoltaikanlage mit einer Spitzenleistung von 3,18 kW. Letztere zeichnet sich durch einige Besonderheiten (Orientierung des Generators, Master-Slave-Betrieb der Wechselrichter) aus. Das Betriebsverhalten der Anlagen wurde ueber einen laengeren Zeitraum untersucht. Im Jahr 1995 erreichte die Photovoltaikanlage mit 689 Vollastbetriebsstunden etwa die Ergebnisse anderer Photovoltaikanlagen in Sachsen. Moegliche hoehere Ertraege werden durch die gewaehlte Orientierung des Generators verhindert. Die Master-Slave-Schaltung der Wechselrichter arbeitete ohne Probleme. Ihre Effektivitaet wurde durch die nicht optimale Abstimmung von Generator

  4. Technical and economic assessment of tethered wind energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, O.; Maekawa, S.

    1984-08-01

    The wind energy existing at high altitude has been investigated as a potential energy resource in the United States. In terms of the average power density, it can be as high as 16 KW/m/sup 2/ at northeastern U.S. sites such as New York, which can be compared to 0.5 KW/m/sup 2/, the maximum ground level value at the U.S. sites. For a lifting generation device, a VTOL concept, new to this type of TWES, which combines the fixed wing with helicopter technology was extensively studied. The cost of electricity (COE) with such a system was determined and found to be competitive to that of fossil fuel in the near future.

  5. Engineering design of 500KW CW collector

    International Nuclear Information System (INIS)

    Kumar, Ramesh; Mishra, Deepak; Prasad, M.; Hannuarakar, P.R.

    2006-01-01

    An electron beam collector for 500kW beam power has been designed to test the electron gun. The gun is designed for 250kW, 350MHz CW Klystron with 50% efficiency. This will also help in preliminary studies related to final collector design for Klystron. This paper presents the design parameters, thermal analysis and mechanical features of the design. Electron trajectory on inside wall of the collector is determined with EGUN and computational flow dynamics simulation was done on ANSYS for cooling requirements. (author)

  6. Low Wind Speed Turbine Project Phase II: The Application of Medium-Voltage Electrical Apparatus to the Class of Variable Speed Multi-Megawatt Low Wind Speed Turbines; 15 June 2004--30 April 2005

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, W.; Behnke, M.

    2005-11-01

    Kilowatt ratings of modern wind turbines have progressed rapidly from 50 kW to 1,800 kW over the past 25 years, with 3.0- to 7.5-MW turbines expected in the next 5 years. The premise of this study is simple: The rapid growth of wind turbine power ratings and the corresponding growth in turbine electrical generation systems and associated controls are quickly making low-voltage (LV) electrical design approaches cost-ineffective. This report provides design detail and compares the cost of energy (COE) between commercial LV-class wind power machines and emerging medium-voltage (MV)-class multi-megawatt wind technology. The key finding is that a 2.5% reduction in the COE can be achieved by moving from LV to MV systems. This is a conservative estimate, with a 3% to 3.5% reduction believed to be attainable once purchase orders to support a 250-turbine/year production level are placed. This evaluation considers capital costs as well as installation, maintenance, and training requirements for wind turbine maintenance personnel. Subsystems investigated include the generator, pendant cables, variable-speed converter, and padmount transformer with switchgear. Both current-source and voltage-source converter/inverter MV topologies are compared against their low-voltage, voltage-source counterparts at the 3.0-, 5.0-, and 7.5-MW levels.

  7. Starting-up sequence of the AWEC-6 0 wind turbine

    International Nuclear Information System (INIS)

    Avia, F.; Cruz, M. de la

    1991-01-01

    One of the most critical status of the wind turbines operation is the starting-up sequence and the connection to the grid, due to the actuating loads that could be several times the loads during operation at rated conditions. Due to this fact, the control strategy is very important during the starting-up sequence in order to minimize the loads on the machine. For this purpose it is necessary to analyze the behaviour of the wind turbine during that sequence in different wind conditions and machine conditions This report shows the graphic Information about fifty starting-up sequences of the AWEC-60 wind turbine of 60 m diameter and 1200 kW of rated power, recorded in April 1991 and covering all the operation range between cut-in and cut-out wind speed. (Author) 2 refs

  8. Techno-economic analysis of a 2.1 kW rooftop photovoltaic-grid-tied system based on actual performance

    International Nuclear Information System (INIS)

    Adaramola, Muyiwa S.

    2015-01-01

    Highlights: • The economic analysis of rooftop PV grid-tied installation is examined. • Based on actual performance, the LCOE of the system is estimated as US$0.246/kW h. • Feed-in-tariff of US$0.356/kW h is estimated with no financial support. • To encourage installation of PV system, financial support of up to 40% of the investment is suggested. - Abstract: As more attention is being focus on the development of renewable energy resources globally, technical and economic assessments of these resources are crucial to ascertain their viability. These assessments can be more meaningful, if they are based on field and actual performance of the renewable energy conversion systems. This study presents the economic analysis of a rooftop 2.07 kW grid-connected photovoltaic energy system installation located in Ås (59.65°N and longitude 10.76°E, and about 105 m above sea level), Norway. Both the annual and monthly costs of energy produced by the system are determined. In addition, the feed-in tariff that can give internal rate of return of about 7.5% on investment on this installation was examined. Based on assumptions used in this study, feed-in-tariff of US$0.356/kW h is estimated for a project with economic life of 25 years with no other financial support. This translates to US$0.110/kW h premium over the levelized cost of energy of US$0.246/kW h generated by the system. However, if the financial support is more than 45% of the initial investment cost, no further premium fee is necessary to support this type of system

  9. The environmental benefits of wind energy

    International Nuclear Information System (INIS)

    Sips, H.W.

    1990-01-01

    Three more or less reliable methods to determine the financial acceptance of the external effects of the use of wind energy are discussed. Attention is paid to the appreciation of external effects based on the environmental pollution or damage, appreciation based on prevented costs (implied valuation), and appreciation based on surveys, by which the willingness of the civilians to pay for a clean environment can be determined. A first indication of the environmental benefits of wind energy based on the above-mentioned methods is 0.04 to 0.08 DFl per kWh. For the total service life of a wind turbine this amounts to 800-1600 DFl per kW. The environmental benefits can be re-calculated in the form of subsidies, increasing the sellback prices or by means of an environmental levy on electric power generated by conventional power plants. 2 figs., 1 tab., 12 refs

  10. Production of electricity from the wind: a preliminary feasibility study for Greece

    Energy Technology Data Exchange (ETDEWEB)

    Galanis, N

    1977-01-01

    Wind statistics for Greece show that the conditions prevailing on the Aegean islands--i.e. considerable amounts of wind energy, small electrical loads and high generation costs--are especially favorable for the installation of wind turbine generators (WTGs). This study gives preliminary design parameters for WTGs at six locations and evaluates their performance. The duration of operation varies from 5000 to 7400 hours annually and the specific production is between 2300 and 3600 kwh/kw. The installation of the WTGs would result in diesel fuel savings corresponding to a month's consumption. Finally, the cost of wind generated electricity will be lower than that from diesel engines one to three years after the installation of the WTGs.

  11. Solar-wind system powers mountain clean-up

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    By using a hybrid solar-wind system, the Japanese have tackled the problem of human excrement left by tourists in mountain lodges and in natural parks by installing flush toilets and wastewater treatment plants. The solar array (4.9 kW{sub p}) consists of 76 panels of single-crystal photovoltaic cells each with an output of 64 Wp. The wind turbines (total capacity 2.1 kW) operate whatever the wind strength or direction. Storage batteries prevent any dip in power which would result from low ambient temperatures. The system can still function at temperatures as low as minus 25{sup o}C. Between November and April when the lodge is closed, the waste is decomposed biologically. A block diagram shows the elements of the system, and details of cost are given. The system won the 1999 New Energy Award.

  12. Measurement of starting characteristics of a remote area Darrieus wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Freere, P. [Monash University, Clayton (Australia). Dept. of Electrical Engineering; Moller, C.; Jespersen, R. [Danish Technical University, Copenhagen (Denmark). Dept. of Electrical Engineering

    1999-07-01

    A 17 kW Darrieus was constructed as a remote area power supply for an independent community outside Melbourne, Australia. After languishing for several years it was reconditioned, but found not to start at wind speeds up to 12 m/s. Therefore, the turbine was modelled by driving it with an electric motor at various rotational speeds over a range of wind speeds. Thus it was possible to measure the turbine starting characteristics, thereby indicating reasons for the turbine's lack of performance. (author)

  13. The DFVLR wind-energy test facility 'Ulrich Huetter' on Schnittlinger Berg

    Science.gov (United States)

    Kussmann, Alfred

    1986-11-01

    The DFVLR test facility for wind-energy systems (named after Ulrich Huetter, the designer of the 100-kW GFRP-rotor W 34 wind turbine first manufactured and tested in the 1950s) is described and illustrated with photographs. The history of the facility is traced, and current operations in gathering, archiving, processing, interpreting, and documenting performance-test data are outlined. The facility includes instrumentation for rotor telemetry, gondola motion measurements, and ground measurements and provides testing services to private users on both contract and leasing bases.

  14. Ijsselmij exploits a large wind park of 7. 5 MW in the Noordoostpolder, Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Nauta, Y

    1988-07-01

    The energy industry Ijsselmij constructed in 1987, along the Westermeerdijk north of Urk, Netherlands, a wind park of 7.5 MW. The wind park, built on the landside of the dike, consists of 25 wind turbines with a rotor diameter of 25 m and a capacity of 300 kW each. The total investment was about 21 million Dutch guilders. The park generates more than 10 million kWh annually supplied to the public electricity grid. The site selection, the foundations, the wind turbines, the electric connection, control unit to generate data, the economic feasibility and some aspects concerning noise pollution and bird damage are discussed. Finally technical data on the wind park are given. 9 figs.

  15. Design of low noise airfoil with high aerodynamic performance for use on small wind turbines

    Institute of Scientific and Technical Information of China (English)

    Taehyung; KIM; Seungmin; LEE; Hogeon; KIM; Soogab; LEE

    2010-01-01

    Wind power is one of the most reliable renewable energy sources and internationally installed capacity is increasing radically every year.Although wind power has been favored by the public in general,the problem with the impact of wind turbine noise on people living in the vicinity of the turbines has been increased.Low noise wind turbine design is becoming more and more important as noise is spreading more adverse effect of wind turbine to public.This paper demonstrates the design of 10 kW class wind turbines,each of three blades,a rotor diameter 6.4 m,a rated rotating speed 200 r/min and a rated wind speed 10 m/s.The optimized airfoil is dedicated for the 75% spanwise position because the dominant source of a wind turbine blade is trailing edge noise from the outer 25% of the blade.Numerical computations are performed for incompressible flow and for Mach number at 0.145 and for Reynolds numbers at 1.02×106 with a lift performance,which is resistant to surface contamination and turbulence intensity.The objectives in the design process are to reduce noise emission,while sustaining high aerodynamic efficiency.Dominant broadband noise sources are predicted by semi-empirical formulas composed of the groundwork by Brooks et al.and Lowson associated with typical wind turbine operation conditions.During the airfoil redesign process,the aerodynamic performance is analyzed to reduce the wind turbine power loss.The results obtained from the design process show that the design method is capable of designing airfoils with reduced noise using a commercial 10 kW class wind turbine blade airfoil as a basis.Therefore,the new optimized airfoil showing 2.9 dB reductions of total sound pressure level(SPL) and higher aerodynamic performance are achieved.

  16. 3D-PTV around Operational Wind Turbines

    Science.gov (United States)

    Brownstein, Ian; Dabiri, John

    2016-11-01

    Laboratory studies and numerical simulations of wind turbines are typically constrained in how they can inform operational turbine behavior. Laboratory experiments are usually unable to match both pertinent parameters of full-scale wind turbines, the Reynolds number (Re) and tip speed ratio, using scaled-down models. Additionally, numerical simulations of the flow around wind turbines are constrained by the large domain size and high Re that need to be simulated. When these simulations are preformed, turbine geometry is typically simplified resulting in flow structures near the rotor not being well resolved. In order to bypass these limitations, a quantitative flow visualization method was developed to take in situ measurements of the flow around wind turbines at the Field Laboratory for Optimized Wind Energy (FLOWE) in Lancaster, CA. The apparatus constructed was able to seed an approximately 9m x 9m x 5m volume in the wake of the turbine using artificial snow. Quantitative measurements were obtained by tracking the evolution of the artificial snow using a four camera setup. The methodology for calibrating and collecting data, as well as preliminary results detailing the flow around a 2kW vertical-axis wind turbine (VAWT), will be presented.

  17. Wind Energy Solutions : to bring renewable energy everywhere

    International Nuclear Information System (INIS)

    Baigent, K.

    2006-01-01

    This presentation provided details of Wind Energy Solutions (WES) Canada's current activities and research innovations. Established initially in Holland in 2004, WES Canada's corporate activities include technology development; licensing, registration and approvals; product development; manufacturing and distribution; and global service and maintenance training. WES Canada is the exclusive importer of WES turbines for Canada and the United States, and offers turnkey wind energy solutions for local dealers and installers. WES product technology aims to provide flexible logistics, as well as to facilitate local production and project development. WES turbines range from 2.5 kW to 250 KW and are available for both on-site power generation and grid-connected applications. The presentation provided specifications for the WES 5 Tulipo wind turbine, a low noise level, low vibration turbine that provides 2 independent safety systems: a failsafe brake on fast shaft of gear; and emergency yawing. A series of photographs demonstrated the installation process of the Tulipo. It was noted that many WES turbines are used in farming applications, as the turbine fits easily on 1 truck, and is easy to install with a foundation made by a local contractor using WES technical drawings engineered for local soil conditions. The turbine is also suitable for factories, harbours, schools and remote villages. It was concluded that the turbines have been specifically engineered for cold climates, as an imbalance control will prevent operation when the blades have significant ice build-up. refs., tabs., figs

  18. Profitability Analysis of Residential Wind Turbines with Battery Energy Storage

    Science.gov (United States)

    She, Ying; Erdem, Ergin; Shi, Jing

    Residential wind turbines are often accompanied by an energy storage system for the off-the-grid users, instead of the on-the-grid users, to reduce the risk of black-out. In this paper, we argue that residential wind turbines with battery energy storage could actually be beneficial to the on-the-grid users as well in terms of monetary gain from differential pricing for buying electricity from the grid and the ability to sell electricity back to the grid. We develop a mixed-integer linear programming model to maximize the profit of a residential wind turbine system while meeting the daily household electricity consumption. A case study is designed to investigate the effects of differential pricing schemes and sell-back schemes on the economic output of a 2-kW wind turbine with lithium battery storage. Overall, based on the current settings in California, a residential wind turbine with battery storage carries more economical benefits than the wind turbine alone.

  19. Low-capacity wind power systems. Technology, legal aspects, economic efficiency; Kleine Windenergieanlagen. Technik - Recht - Wirtschaftlichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Eggersgluess, Walter [Landwirtschaftskammer Schleswig-Holstein, Rendsburg (Germany); Eckel, Henning; Hartmann, Stefan [Kuratorium fuer Technik und Bauwesen in der Landwirtschaft e.V. (KTBL), Darmstadt (Germany)

    2012-07-01

    In what conditions will investments in a low-capacity wind power plant be profitable? This leaflet intends to provide a decision aid for farmers and other land owners interested in thes subject. It outlines the technology of low-capacity wind power systems, goes into site selection, expected yields and legal boundary conditions. The most important economic data are defined, and the economic efficiency of wind power plants of 7.5 to 25 kW is discussed. The text is supplemented by useful internet links. [German] Unter welchen Bedingungen rechnet sich die Investition in eine kleine Windenergieanlage? Das Heft hilft Landwirten sowie allen anderen investitionswilligen Grundstueckseigentuemern fuer sich Antworten auf diese Fragen zu finden und die richtigen Entscheidungen zu treffen. Es gibt einen Ueberblick ueber die Technik kleiner Windenergieanlagen, beschreibt was den richtigen Standort auszeichnet, mit welchen Energieertraegen gerechnet werden kann und welchen rechtlichen Rahmenbedingungen Bau und Betrieb der Anlagen unterliegen. Die wichtigsten wirtschaftlichen Kenngroessen werden definiert und die Wirtschaftlichkeit kleiner Windenergieanlagen anhand von Beispielanlagen im Leistungsbereich von 7,5 bis 25 kW diskutiert. Nuetzliche Internetadressen zum Thema Windenergie runden das Informationsangebot ab.

  20. Large wind turbine development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Zervos, A. [Center for Renewable Energy Sources, Attikis (Greece)

    1996-12-31

    During the last few years we have witnessed in Europe the development of a new generation of wind turbines ranging from 1000-1500 kW size. They are presently being tested and they are scheduled to reach the market in late 1996 early 1997. The European Commission has played a key role by funding the research leading to the development of these turbines. The most visible initiative at present is the WEGA program - the development, together with Europe`s leading wind industry players of a new generation of turbines in the MW range. By the year 1997 different European manufacturers will have introduced almost a dozen new MW machine types to the international market, half of them rated at 1.5 MW. 3 refs., 3 tabs.

  1. Low cost infrastructure solutions for small embedded wind generators

    Energy Technology Data Exchange (ETDEWEB)

    Robb, C.

    2003-07-01

    This report gives details of a project to demonstrate novel economic solutions to increase the potential for installing small-scale embedded wind generator systems at many UK sites which have so far been dismissed as too difficult. Details are given of the first phase of the study which examined current solutions to infrastructure problems and potential techniques. The use of drilled rock anchor foundations to minimise the need for delivery of ready-mix concrete to wind turbine sites, and the use of a winch and A-frame system for erecting a wind turbine to avoid the use of cranes are discussed. The demonstration of the installation of a 50kW wind turbine on the Isle of Luing in Scotland where there is no access for cranes or larger vehicles in the second phase of the project is described. The potential for the use of these techniques on larger wind turbines is considered.

  2. Reliability measures for indexed semi-Markov chains applied to wind energy production

    International Nuclear Information System (INIS)

    D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio

    2015-01-01

    The computation of the dependability measures is a crucial point in many engineering problems as well as in the planning and development of a wind farm. In this paper we address the issue of energy production by wind turbines by using an indexed semi-Markov chain as a model of wind speed. We present the mathematical model, the data and technical characteristics of a commercial wind turbine (Aircon HAWT-10kW). We show how to compute some of the main dependability measures such as reliability, availability and maintainability functions. We compare the results of the model with real energy production obtained from data available in the Lastem station (Italy) and sampled every 10 min. - Highlights: • Semi-Markov models. • Time series generation of wind speed. • Computation of availability, reliability and maintainability.

  3. Noise annoyances from wind power: Survey of the population living close to a wind power plant. Final report: Part 3 Main study

    International Nuclear Information System (INIS)

    Pedersen, Eja; Persson-Waye, K.

    2002-02-01

    To evaluate the occurrence of annoyance from wind turbines, a study was performed in Laholm in May 2000. The aim was to obtain dose response relationships between calculated sound levels and noise annoyance and appropriate sound description as well as analysing the influence of other variables on noise annoyance. A questionnaire survey was performed in 6 areas comprising 16 wind turbines, of which 14 had an effect of 600 kW. The purpose of the study was masked. Among questions on living conditions in the countryside, questions directly related to wind turbines were included. The study population (n=518) comprised one randomly selected subject between the ages of 18 to 75 years in each household living within a calculated wind turbine sound level of 25 to 40 dBA. The response rate was 68.7% (n=356). Calculated distributions of A-weighted sound level were performed for each area and plotted on geographical maps in 2.5 dBA steps. Each dwelling could thus be given a sound level within an interval of 2.5 dBA. The most frequently occurring source of noise annoyance was noise from rotor blades. The proportions of respondents annoyed by noise increased with calculated sound level. Among respondents exposed to sound levels of 35.0-37.5 dBA, 43% responded themselves to be rather or much annoyed. A-weighted sound level was only one variable explaining annoyance. Annoyance was correlated to a larger extent by the intrusiveness of the sound character swishing. Noise annoyance was interrelated to the respondents' opinion of the visual impact of wind turbines, while attitude towards wind power in general had no greater influence. Disturbance of spoilt view was reported to a similar degree as noise disturbance. Further investigations are needed to clarify factors of importance for the disturbance of view. All the wind turbines in the study had constant rotation speed. The greater wind turbines that are now erected often have variable speed, which may lead to a sound comprising

  4. Design and Experimental Analysis of an Exhaust Air Energy Recovery Wind Turbine Generator

    Directory of Open Access Journals (Sweden)

    Ahmad Fazlizan

    2015-06-01

    Full Text Available A vertical axis wind turbine (VAWT was positioned at the discharge outlet of a cooling tower electricity generator. To avoid a negative impact on the performance of the cooling tower and to optimize the turbine performance, the determination of the VAWT position in the discharge wind stream was conducted by experiment. The preferable VAWT position is where the higher wind velocity matches the positive torque area of the turbine rotation. With the proper matching among the VAWT configurations (blade number, airfoil type, operating tip-speed-ratio, etc. and exhaust air profile, the turbine system was not only able to recover the wasted kinetic energy, it also reduced the fan motor power consumption by 4.5% and increased the cooling tower intake air flow-rate by 11%. The VAWT had a free running rotational speed of 479 rpm, power coefficient of 10.6%, and tip-speed-ratio of 1.88. The double multiple stream tube theory was used to explain the VAWT behavior in the non-uniform wind stream. For the actual size of a cooling tower with a 2.4 m outlet diameter and powered by a 7.5 kW fan motor, it was estimated that a system with two VAWTs (side-by-side can generate 1 kW of power which is equivalent to 13% of energy recovery.

  5. 2-kW single-mode fiber laser employing bidirectional-pump scheme

    Science.gov (United States)

    Zhang, Fan; Zheng, Wenyou; Shi, Pengyang; Zhang, Xinhai

    2018-01-01

    2kW single-mode fiber laser with two cascade home-made cladding light strippers (CLSs) by employing bidirectionalpump scheme has been demonstrated. 2.009 kW signal power is obtained when pump power is 2.63 kW and the slope efficiency is 76.6%. Raman Stokes light is less than -47 dB at 2.009 kW even with a 10-m delivery fiber with core/inner cladding diameter of 20/400um. The beam quality M2<=1.2 and the spectral FWHM bandwidth is 4.34nm. There is no transverse mode instability and the output power stability of +/-0.14% is achieved by special thermal management for a more uniform temperature distribution on the Yb-doped gain fiber.

  6. Birds and wind turbines: can they co-exist?

    International Nuclear Information System (INIS)

    1996-01-01

    This one-day seminar was intended to provide a forum for information exchange and discussion between those concerned with the potential effects of wind turbines on bird life and to produce recommendations that would be helpful in future wind power developments, environmental impact assessments and related research activities. The six papers presented cover the following topics: impacts, mitigation and monitoring of collisions, disturbance in the construction phase and habitat loss; bird protection and the law with particular reference to the burden of proof required from developers in a planning context in the United Kingdom; continuing studies on the birds of Blyth Harbour in the UK where nine 300kW wind turbines are mounted on a pier jutting out into the sea; an overview of European and American experience; the policy and experience of the Royal Society for the Protection of Birds; wind farm design in the light of previous experience. The discussion arising out of each paper is summarised. (UK)

  7. Theoretical design study of the MSFC wind-wheel turbine

    Science.gov (United States)

    Frost, W.; Kessel, P. A.

    1982-01-01

    A wind wheel turbine (WWT) is studied. Evaluation of the probable performance, possible practical applications, and economic viability as compared to other conventional wind energy systems is discussed. The WWT apparatus is essentially a bladed wheel which is directly exposed to the wind on the upper half and exposed to wind through multiple ducting on the lower half. The multiple ducts consist of a forward duct (front concentrator) and two side ducts (side concentrators). The forced rotation of the wheel is then converted to power through appropriate subsystems. Test results on two simple models, a paper model and a stainless steel model, are reported. Measured values of power coefficients over wind speeds ranging from 4 to 16 m/s are given. An analytical model of a four bladed wheel is also developed. Overall design features of the wind turbine are evaluated and discussed. Turbine sizing is specified for a 5 and 25 kW machine. Suggested improvements to the original design to increase performance and performance predictions for an improved WWT design are given.

  8. Assessment of Gearbox Operational Loads and Reliability under High Mean Wind Speeds

    OpenAIRE

    Dabrowski, Dariusz; Natarajan, Anand

    2015-01-01

    This paper investigates the dynamic loads occurring in the drivetrain of wind turbines with a focus on offshore applications. Herein a model of the gearbox of the 5 MW wind turbine is presented. The model is developed in a multi-body framework using commercial software MSC ADAMS. Validation of the model was based on the experimental data provided by NREL for 750 kW prototype gearbox. Failures of gearboxes caused by high dynamic loads have a significant influence on the cost of operation of wi...

  9. A SUPER-EDDINGTON, COMPTON-THICK WIND IN GRO J1655–40?

    Energy Technology Data Exchange (ETDEWEB)

    Neilsen, J.; Homan, J. [MIT Kavli Institute for Astrophysics and Space Research, Cambridge, MA 02139 (United States); Rahoui, F. [European Southern Observatory, Karl Schwarzschild-Strasse 2, D-85748 Garching bei Munchen (Germany); Buxton, M., E-mail: jneilsen@space.mit.edu [Department of Astronomy, Yale University, P.O. Box 208101, New Haven, CT 06520-8101 (United States)

    2016-05-01

    During its 2005 outburst, GRO J1655–40 was observed at high spectral resolution with the Chandra High-Energy Transmission Grating Spectrometer, revealing a spectrum rich with blueshifted absorption lines indicative of an accretion disk wind—apparently too hot, too dense, and too close to the black hole to be driven by radiation pressure or thermal pressure (Miller et al.). However, this exotic wind represents just one piece of the puzzle in this outburst, as its presence coincides with an extremely soft and curved X-ray continuum spectrum, remarkable X-ray variability (Uttley and Klein-Wolt), and a bright, unexpected optical/infrared blackbody component that varies on the orbital period. Focusing on the X-ray continuum and the optical/infrared/UV spectral energy distribution, we argue that the unusual features of this “hypersoft state” are natural consequences of a super-Eddington Compton-thick wind from the disk: the optical/infrared blackbody represents the cool photosphere of a dense, extended outflow, while the X-ray emission is explained as Compton scattering by the relatively cool, optically thick wind. This wind obscures the intrinsic luminosity of the inner disk, which we suggest may have been at or above the Eddington limit.

  10. Quantitative defects detection in wind turbine blade using optical infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Kwaon, Koo Ahn [School of Aerospace System Engineering, UST, Daejeon (Korea, Republic of); Choi, Man Yong; Park, Hee Sang; Park, Jeong Hak; Huh, Yong Hak; Choi, Won Jai [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2015-02-15

    A wind turbine blade is an important component in wind-power generation, and is generally exposed to harsh environmental conditions. Ultrasonic inspection is mainly used to inspect such blades, but it has been difficult to quantify defect sizes in complicated composite structures. Recently, active infrared thermography has been widely studied for inspecting composite structures, in which thermal energy is applied to an object, and an infrared camera detects the energy emitted from it. In this paper, a calibration method for active optical lock-in thermography is proposed to quantify the size. Inclusion, debonding and wrinkle defects, created in a wind blade for 100 kW wind power generation, were all successfully detected using this method. In particular, a 50.0 mm debonding defect was sized with 98.0% accuracy.

  11. Design of Radial Inflow Turbine for 30 kW Microturbine

    Directory of Open Access Journals (Sweden)

    Sangsawangmatum Thanate

    2017-01-01

    Full Text Available Microturbines are small gas turbines that have the capacity range of 25-300 kW. The main components of microturbine are compressor, turbine, combustor and recuperator. This research paper focuses on the design of radial inflow turbine that operates in 30 kW microturbine. In order to operate the 30 kW microturbine with the back work ratio of 0.5, the radial inflow turbine should be designed to produce power at 60 kW. With the help of theory of turbo-machinery and the analytical methods, the design parameters are derived. The design results are constructed in 3D geometry. The 3D fluid-geometry is validated by computational fluid dynamics (CFD simulation. The simulation results show the airflow path, the temperature distribution, the pressure distribution and Mach number. According to the simulation results, there is no flow blockage between vanes and no shock flow occurs in the designed turbine.

  12. Parametric study on off-design aerodynamic performance of a horizontal axis wind turbine blade and proposed pitch control

    International Nuclear Information System (INIS)

    Najafian Ashrafi, Z.; Ghaderi, M.; Sedaghat, A.

    2015-01-01

    Highlights: • A pitch controlled 200 kW HAWT blade is designed with BEM for off-design conditions. • Parametric study conducted on power coefficient, axial and angular induction factors. • The optimal pitch angles were determined at off-design operating conditions. - Abstract: In this paper, a 200 kW horizontal axis wind turbine (HAWT) blade is designed using an efficient iterative algorithm based on the blade element momentum theory (BEM) on aerodynamic of wind turbines. The effects of off-design variations of wind speed are investigated on the blade performance parameters according to constant rotational speed of the rotor. The performance parameters considered are power coefficient, axial and angular induction factors, lift and drag coefficients on the blade, angle of attack and angle of relative wind. At higher or lower wind speeds than the designed rated speed, the power coefficient is reduced due to considerable changes in the angle of attacks. Therefore, proper pitch control angles were calculated to extract maximum possible power at various off-design speeds. The results showed a considerable improvement in power coefficient for the pitch controlled blade as compared with the baseline design in whole operating range. The present approach can be equally employed for determining pitch angles to design pitch control system of medium and large-scale wind turbines

  13. 1000kW phosphoric acid fuel cell power plant. Outline of the plant

    Energy Technology Data Exchange (ETDEWEB)

    Shinobe, Kenji; Suzuki, Kazuo; Kaneko, Hideo

    1988-02-10

    The outline of the 1000KW phosphoric acid fuel cell power plant, developed as part of the Moonlight plan, was described. The plant was composed of 4 stacks of 260KW DC output. They were devided into two train with 680V and 765A. The generation efficiency of the plant was 40% and more. Steam reforming of natural gas was used. As the fuel, fuel cell exhaust gas was used in composition with the natural gas. The DC-AC inverter had an efficiency of 96%. The capacity of hot water generator and demineralized water plant for cell cooling were 2t/h and 1.6t/h, respectively, and air-system was incorporated. In September of 1987, the plant has succeeded in 1000KW power generation, and put in operation now. Under the 100% loaded condition, each cell had a voltage of 0.7V with little variation, and the current was 200mA/cm/sup 2/. No problems were found in cooling conditions and in the control of interpole differential pressure. The reformer has been operated for 1200h scince its commisioning, and had experiences of 100 times on start up-shut down operations, the reformer also indicated good performances in the gas compositions. The starting time of 8h and the load follow-up rate 10%/min remain as the subjects for shortening. DC-AC conversion was good. The concentration of NOx and the noise level satisfied the target values. (12 figs, 1 tab)

  14. Wind-US Users Guide Version 4.0

    Science.gov (United States)

    Yoder, Dennis A.

    2016-01-01

    Wind-US is a computational platform which may be used to numerically solve various sets of equations governing physical phenomena. Currently, the code supports the solution of the Euler and Navier-Stokes equations of fluid mechanics, along with supporting equation sets governing turbulent and chemically reacting flows. Wind-US is a product of the NPARC Alliance, a partnership between the NASA Glenn Research Center (GRC) and the Arnold Engineering Development Complex (AEDC) dedicated to the establishment of a national, applications-oriented flow simulation capability. The Boeing Company has also been closely associated with the Alliance since its inception, and represents the interests of the NPARC User's Association. The "Wind-US User's Guide" describes the operation and use of Wind-US, including: a basic tutorial; the physical and numerical models that are used; the boundary conditions; monitoring convergence; the files that are read and/or written; parallel execution; and a complete list of input keywords and test options. For current information about Wind-US and the NPARC Alliance, please see the Wind-US home page at http://www.grc.nasa.gov/WWW/winddocs/ and the NPARC Alliance home page at http://www.grc.nasa.gov/WWW/wind/.

  15. Research on industrial 10kW CO2 laser achieves major breakthrough

    Science.gov (United States)

    1991-01-01

    The industrial 10kW CO2 laser is one of the items which the industrially developed nations are competing to develop. This laser is capable of continuous output power of over 10kW and can operate continuously for more than 6 hours. The 10kW CO2 laser developed as a key task of China's 7th Five-Year Plan and all its technological targets such as output power, electrooptical conversion efficiency and primary charging continuous operating time, have reached the level of world advancement, allowing China to enter the ranks of international advancement in the area of laser technology. The industrial 10kW CO2 laser can have wide application in such areas of industry as heat treating, machining, welding and surface treatment in industries such as steel, automobiles, ship building and aircraft manufacturing. For instance, using the high-efficiency laser beams of this 10kW laser to treat rollers, fan blades and automotive cylinder blocks can increase the life of these parts and produce large economic benefits. At present, industrial tests of gear welding is already being done on this 10kW laser.

  16. Current Background Noise Sources and Levels in the NASA Ames 40- by 80-Foot Wind Tunnel: A Status Report

    Science.gov (United States)

    Allen, Christopher S.; Jaeger, Stephen; Soderman, Paul; Koga, Dennis (Technical Monitor)

    1999-01-01

    Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various

  17. Electrification of remote coastal areas through wind-energy

    International Nuclear Information System (INIS)

    Hassan, M.

    2005-01-01

    It has been estimated that with the present utilization of resources, the country will run out of oil and gas reserves in one and a half decade. There is, thus, a strong need to take measures to tap other resources of energy, which are abundantly available in Pakistan. The exploitation of these resources for production of electricity on local basis, under participatory system of development, would supplement energy being provided by WAPDA, at a much lower cost due to the avoidance of laying high-tension cables, transformers, and meters, etc., and the manpower required to maintain the system. Balochistan is a large but thinly populated province of Pakistan. The situation of electrification in Balochistan is serious, as a vast majority of the population is without access to electricity. Many villages and districts of Balochistan do not have centralized electricity-grid and there is no hope, in the near future, to have one because the extension of grid to such remote and scattered settlements is neither practical nor economically viable. In Balochistan, out of a total number of 13,700 villages, WAPDA has merely electrified 3,154 villages due to the high cost involved in developing the necessary infrastructure. Not surprisingly, this situation is a source of discontentment among the people of the Province. Pakistan has a considerable potential of wind-energy in the coastal belt of Balochistan and Sindh, as well as in the desert areas of Punjab and Sindh, which if utilized effectively, can not only electrify all remote coastal villages, but the electricity so produced also can be fed to the national grid. This renewable source of energy has however, so far, not been utilized. Recently, fourteen small wind-turbines (300-500 watts) were procured and installed by PCRET under Sino-Pak S and T Protocol. Being encouraged by performance of these small wind- turbines, a further 120 wind turbines (JOO of 500 watts and 20 wind-turbines of 5kW each) are being installed. The small

  18. Room/corner tests of wall linings with 100/300 kW burner

    Science.gov (United States)

    M. A. Dietenberger; O. Grexa; R. H. White; M. S. Sweet; M. Janssens

    1995-01-01

    Six room/comer tests of common wall linings were conducted with gypsum-lined ceiling exposed to propane burning at 100 kW for 10 min followed by 300 kW for 10 min. This test protocol is an option provided by ISO 9705. The flashover event occurred at 1,000 kW rate of heat release within several seconds of observing flames out the doorway. The time to flashover of the...

  19. Regional Focus on Small-scale wind power (<50kW) in southeastern Sweden within the Network for wind farms. Final Report, Project No. 31852-1. ; Regional Satsning paa Smaaskalig vindkraft (<50kW) i sydoestra Sverige inom Naetverket foer vindbruk. Slutrapport, projekt nr 31852-1.

    Energy Technology Data Exchange (ETDEWEB)

    Tyrberg, Lennart (ed.)

    2011-07-01

    Energy Agency for Southeast Sweden AB, the Swedish Network for wind farming and the EU project RuralRES have collaborated in this project. The project has resulted in a competence buildup and dissemination of small-scale wind power knowledge. The project has, among other things documented good practices and performs feasibility studies for establishment of small scale wind power. This work has led to an understanding of preconditions for a successful investment in small-scale wind power. The dissemination of this knowledge here in the region, in other parts of Sweden and to other partners in the EU project has contributed to a more realistic level of expectations on small-scale wind power, something that is very important for the industry's continued development. A good wind location is the most important prerequisite for a successful wind power project; this applies to small as well as large-scale wind power. Availability of reliable wind turbines with good performance is important for the development of the industry. Further, it should be reasonably easy to get building permits and permits for electricity connection. The growth might be stimulated by the introduction of net charging and an adaptation of the electricity certificate system for small producers.

  20. Aerodynamic characteristics of the modified 40- by 80-foot wind tunnel as measured in a 1/50th-scale model

    Science.gov (United States)

    Smith, Brian E.; Naumowicz, Tim

    1987-01-01

    The aerodynamic characteristics of the 40- by 80-Foot Wind Tunnel at Ames Research Center were measured by using a 1/50th-scale facility. The model was configured to closely simulate the features of the full-scale facility when it became operational in 1986. The items measured include the aerodynamic effects due to changes in the total-pressure-loss characteristics of the intake and exhaust openings of the air-exchange system, total-pressure distributions in the flow field at locations around the wind tunnel circuit, the locations of the maximum total-pressure contours, and the aerodynamic changes caused by the installation of the acoustic barrier in the southwest corner of the wind tunnel. The model tests reveal the changes in the aerodynamic performance of the 1986 version of the 40- by 80-Foot Wind Tunnel compared with the performance of the 1982 configuration.

  1. The production of wind-generated electricity

    International Nuclear Information System (INIS)

    2013-11-01

    After some key data on installed wind power and its evolution in the World (notably in China and in the USA), in European countries and in France, an overview of the sector economic evolution in France in terms of jobs in different fields (fabrication, electricity production, studies and installations), this publication comments the various benefits of wind energy and its necessary framework for a sane development. Strengths are discussed: a local and clean energy source, a predictable and manageable energy source, an increasing competitiveness. Issues to be considered are also discussed: control of acoustic and landscape impacts, protection of biodiversity, management of interactions with military, meteorological and civil aviation radars, a necessary more steady and coherent regulation. After a discussion of the possibilities offered by small wind energy installations (between 1 and 36 kW), actions undertaken by the ADEME are overviewed. A conclusion outlines the role of wind energy on the supply-demand balance in the French power system, its contribution to the reduction of greenhouse gas emissions, the positive environmental impact, the importance of societal appropriation, and the importance of developing this sector while keeping on reducing consumptions

  2. 3 kW Stirling engine for power and heat production

    DEFF Research Database (Denmark)

    Thorsen, Jan Eric; Bovin, Jonas Kabell; Carlsen, Henrik

    1996-01-01

    A new 3 kW Beta-type Stirling engine has been developed. The engine uses natural gas as fuel and is designed for use as a small combined heat and power plant for single family houses. The electrical power is supplied to the grid. The engine is made as a hermetic device, where the crank mechanism...... and the alternator are built into a pressurized crank casing. The engine produces 3 kW of shaft power corresponding to 2.4 kW of electric power. The heat input is 10 kW representing a shaft efficiency of 30% and an electric efficiency of 24%. Helium at 8 MPa mean pressure is used as the working gas. The crank...... for X-heads. A grease-lubricated needle and ball bearings are used in the kinematic crank mechanism. The burner includes an air preheater and a water jacket which makes it possible to utilize nearly all of the heat from the combustion gases. The performance of the engine has been tested as a function...

  3. Examining the feasibility of converting New York State’s all-purpose energy infrastructure to one using wind, water, and sunlight

    International Nuclear Information System (INIS)

    Jacobson, Mark Z.; Howarth, Robert W.; Delucchi, Mark A.; Scobie, Stan R.; Barth, Jannette M.; Dvorak, Michael J.; Klevze, Megan; Katkhuda, Hind; Miranda, Brian; Chowdhury, Navid A.; Jones, Rick; Plano, Larsen; Ingraffea, Anthony R.

    2013-01-01

    This study analyzes a plan to convert New York State's (NYS's) all-purpose (for electricity, transportation, heating/cooling, and industry) energy infrastructure to one derived entirely from wind, water, and sunlight (WWS) generating electricity and electrolytic hydrogen. Under the plan, NYS's 2030 all-purpose end-use power would be provided by 10% onshore wind (4020 5-MW turbines), 40% offshore wind (12,700 5-MW turbines), 10% concentrated solar (387 100-MW plants), 10% solar-PV plants (828 50-MW plants), 6% residential rooftop PV (∼5 million 5-kW systems), 12% commercial/government rooftop PV (∼500,000 100-kW systems), 5% geothermal (36 100-MW plants), 0.5% wave (1910 0.75-MW devices), 1% tidal (2600 1-MW turbines), and 5.5% hydroelectric (6.6 1300-MW plants, of which 89% exist). The conversion would reduce NYS's end-use power demand ∼37% and stabilize energy prices since fuel costs would be zero. It would create more jobs than lost because nearly all NYS energy would now be produced in-state. NYS air pollution mortality and its costs would decline by ∼4000 (1200–7600) deaths/yr, and $33 (10–76) billion/yr (3% of 2010 NYS GDP), respectively, alone repaying the 271 GW installed power needed within ∼17 years, before accounting for electricity sales. NYS's own emission decreases would reduce 2050 U.S. climate costs by ∼$3.2 billion/yr. - Highlights: ► New York State's all-purpose energy can be derived from wind, water, and sunlight. ► The conversion reduces NYS end-use power demand by ∼37%. ► The plan creates more jobs than lost since most energy will be from in state. ► The plan creates long-term energy price stability since fuel costs will be zero. ► The plan decreases air pollution deaths 4000/yr ($33 billion/yr or 3% of NYS GDP)

  4. Critical Speed Control for a Fixed Blade Variable Speed Wind Turbine

    Directory of Open Access Journals (Sweden)

    Morgan Rossander

    2017-10-01

    Full Text Available A critical speed controller for avoiding a certain rotational speed is presented. The controller is useful for variable speed wind turbines with a natural frequency in the operating range. The controller has been simulated, implemented and tested on an open site 12 kW vertical axis wind turbine prototype. The controller is based on an adaptation of the optimum torque control. Two lookup tables and a simple state machine provide the control logic of the controller. The controller requires low computational resources, and no wind speed measurement is needed. The results suggest that the controller is a feasible method for critical speed control. The skipping behavior can be adjusted using only two parameters. While tested on a vertical axis wind turbine, it may be used on any variable speed turbine with the control of generator power.

  5. Background and system description of the Mod 1 wind turbine generator

    Science.gov (United States)

    Ernst, E. H.

    1978-01-01

    The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.

  6. Design Optimization and Site Matching of Direct-Drive Permanent Magnet Wind Generator Systems

    DEFF Research Database (Denmark)

    Li, H.; Chen, Zhe

    2009-01-01

    This paper investigates the possible site matching of the direct-drive wind turbine concepts based on the electromagnetic design optimization of permanent magnet (PM) generator systems. Firstly, the analytical models of a three-phase radial-flux PM generator with a back-to-back power converter...... of the maximum wind energy capture, the rotor diameter and the rated wind speed of a direct-drive wind turbine with the optimum PM generator are determined. The annual energy output (AEO) is also presented using the Weibull density function. Finally, the maximum AEO per cost (AEOPC) of the optimized wind...... are presented. The optimum design models of direct-drive PM wind generation system are developed with an improved genetic algorithm, and a 500-kW direct-drive PM generator for the minimal generator active material cost is compared to demonstrate the effectiveness of the design optimization. Forty-five PM...

  7. Design of a compressed air energy storage system for hydrostatic wind turbines

    Directory of Open Access Journals (Sweden)

    Ammar E. Ali

    2018-03-01

    Full Text Available Integration of Compressed Air Energy Storage (CAES system with a wind turbine is critical in optimally harvesting wind energy given the fluctuating nature of power demands. Here we consider the design of a CAES for a wind turbine with hydrostatic powertrain. The design parameters of the CAES are determined based on simulation of the integrated system model for a combination of these parameter values, namely the compression ratios of the air compressors and the expanders and the air tank size. The results of the simulations were used to choose the best design parameters, which would produce the best stable performance through increased energy output of the integrated CAES and wind turbine based on the intermittent wind profile. Simulation results for a 600 kW rated power wind turbine with integrated CAES indicate that increasing the tank size and compression ratio will improve the overall power quality through increased energy output up to a limit beyond which the power quality exhibits only marginal improvement.

  8. Design and operating experience on the US Department of Energy experimental Mod-0 100-kW wind turbine

    Science.gov (United States)

    Glasgow, J. C.; Birchenough, A. G.

    1978-01-01

    The experimental wind turbine was designed and fabricated to assess technology requirements and engineering problems of large wind turbines. The machine has demonstrated successful operation in all of its design modes and served as a prototype developmental test bed for the Mod-0A operational wind turbines which are currently used on utility networks. The mechanical and control system are described as they evolved in operational tests and some of the experience with various systems in the downwind rotor configurations are elaborated.

  9. Full-load converter connected asynchronous generators for MW class wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Akhmatov, Vladislav

    2005-06-15

    Wind turbines equipped with full-load converter-connected asynchronous generators are a known concept. These have rating up to hundreds of kW and are a feasible concept for MW class wind turbines and may have advantages when compared to conventional wind turbines with directly connected generators. The concept requires the use of full-scale frequency converters, but the mechanical gearbox is smaller than in conventional wind turbines of the same rating. Application of smaller gearbox may reduce the no-load losses in the wind turbines, which is why such wind turbines with converter connected generators may start operation at a smaller wind speed. Wind turbines equipped with such converted connected asynchronous generators are pitch-controlled and variable-speed. This allows better performance and control. The converter control may be applied to support the grid voltage at short-circuit faults and to improve the fault-ride-through capability of the wind turbines, which makes the concepts relevant for large wind farms. The Danish transmission system operator Energinet-DK has implemented the general model of wind turbines equipped with converter connected asynchronous generators with the simulation tool Powerfactory (DlgSilent). The article presents Energinet-DK's experience of modeling this feasible wind turbine concept. (Author)

  10. WindPACT Turbine Design Scaling Studies: Technical Area 4 - Balance-of-Station Cost; ANNUAL

    International Nuclear Information System (INIS)

    Shafer, D. A.; Strawmyer, K. R.; Conley, R. M.; Guidinger J. H.; Wilkie, D. C.; Zellman, T. F.

    2001-01-01

    DOE's Wind Partnerships for Advanced Component Technologies (WindPACT) program explores the most advanced wind-generating technologies for improving reliability and decreasing energy costs. The first step in the WindPact program is a scaling study to bound the optimum sizes for wind turbines, to define size limits for certain technologies, and to scale new technologies. The program is divided into four projects: Composite Blades for 80-120-meter Rotors; Turbine, Rotor, and Blade Logistics; Self-Erecting Tower and Nacelle Feasibility; and Balance-of-Station Cost. This report discusses balance-of-station costs, which includes the electrical power collector system, wind turbine foundations, communications and controls, meteorological equipment, access roadways, crane pads, and the maintenance building. The report is based on a conceptual 50-megawatt (MW) wind farm site near Mission, South Dakota. Cost comparisons are provided for four sizes of wind turbines: 750 kilowatt (kW), 2.5 MW, 5.0 MW, and 10.0 MW

  11. Hybrid power system (hydro, solar and wind) for rural electricity generation

    International Nuclear Information System (INIS)

    Mahinda Kurukulasuriya

    2000-01-01

    Generation of affordable cheap electric energy for rural development by a hybrid power system (10-50 kW) of hydropower, solar and wind energies on self determining basis and computer application to determine its performance. In this paper the following topics were discussed, design of hybrid power system, its justification and economic analysis, manufacturing and installation of the system. (Author)

  12. A combined aeroelastic-aeroacoustic model for wind turbine noise: Verification and analysis of field measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Fischer, Andreas

    2017-01-01

    In this paper, semi-empirical engineering models for the three main wind turbine aerodynamic noise sources, namely, turbulent inflow, trailing edge and stall noise, are introduced. They are implemented into the in-house aeroelastic code HAWC2 commonly used for wind turbine load calculations...... and design. The results of the combined aeroelastic and aeroacoustic model are compared with field noise measurements of a 500kW wind turbine. Model and experimental data are in fairly good agreement in terms of noise levels and directivity. The combined model allows separating the various noise sources...... and highlights a number of mechanisms that are difficult to differentiate when only the overall noise from a wind turbine is measured....

  13. Development of 20 kW input power coupler for 1.3 GHz ERL main linac. Component test at 30 kW IOT test stand

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Umemori, Kensei; Sakanaka, Shogo; Takahashi, Takeshi; Furuya, Takaaki; Shinoe, Kenji; Ishii, Atsushi; Nakamura, Norio; Sawamura, Masaru

    2009-01-01

    We started to develop an input coupler for a 1.3 GHz ERL superconducting cavity. Required input power is about 20 kW for the cavity acceleration field of 20 MV/m and the beam current of 100 mA in energy recovery operation. The input coupler is designed based on the STF-BL input coupler and some modifications are applied to the design for the CW 20 kW power operation. We fabricated input coupler components such as ceramic windows and bellows and carried out the high-power test of the components by using a 30 kW IOT power source and a test stand constructed for the highpower test. In this report, we mainly describe the results of the high-power test of ceramic window and bellows. (author)

  14. An extensive evaluation of wind resource using new methods and strategies for development and utilizing wind power in Mah-shahr station in Iran

    International Nuclear Information System (INIS)

    Nedaei, Mojtaba; Assareh, Ehsanolah; Biglari, Mojtaba

    2014-01-01

    Highlights: • In this research, results suggest that the Weibull distribution is the best function to model the wind data in Mah-shahr. • The compatibility of the wind data with three methods of estimating Weibull parameters was assessed. • An extreme analysis of wind in Mah-shahr was done to determine the maximum gust wind speeds over a 50-year return period. • An extensive economic evaluation of installing a wind park was performed on RETScreen® software. - Abstract: In this study, the 10-min period measured short-term wind speed data at 10 m and 40 m heights for Mah-shahr station in Iran was statistically analyzed to determine the potential of wind power generation. In addition in this paper different distribution functions are compared to each other in order to find the best distribution in Mah-shahr which is compatible with the wind data. It is found that the Weibull distribution is the best function to model the wind data in Mah-shahr. It should also be mentioned that the different methods for calculating Weibull parameters were used and compared to each other. Moreover an extreme analysis of wind data in Mah-shahr was carried out to determine the maximum gust wind speed over a 50-year return period (Ve50). Using the method of “periodic maxima” for analysis of extreme winds, it was revealed that the 50-year wind speed at 80 m in Mah-shahr which is 39.5 m/s is lower than usual values of Ve50 limits for different wind turbines. This means that the risk of extreme wind gusts in Mah-shahr might not be a problem for installation of wind turbines. From the primary evaluation of wind data in Mah-shahr it is found the studied site has an acceptable potential of wind power for electricity generation. Energy production of different wind turbines at different heights is determined. Then a simple economic evaluation carried out to determine whether studied site is suitable for development of commercial or small and residential wind turbines. It became clear

  15. Power Electronics Control of Wind Energy in Distributed Power System

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  16. Wind-tunnel investigation of the thrust augmentor performance of a large-scale swept wing model. [in the Ames 40 by 80 foot wind tunnel

    Science.gov (United States)

    Koenig, D. G.; Falarski, M. D.

    1979-01-01

    Tests were made in the Ames 40- by 80-foot wind tunnel to determine the forward speed effects on wing-mounted thrust augmentors. The large-scale model was powered by the compressor output of J-85 driven viper compressors. The flap settings used were 15 deg and 30 deg with 0 deg, 15 deg, and 30 deg aileron settings. The maximum duct pressure, and wind tunnel dynamic pressure were 66 cmHg (26 in Hg) and 1190 N/sq m (25 lb/sq ft), respectively. All tests were made at zero sideslip. Test results are presented without analysis.

  17. Design of High Performance Permanent-Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Chun-Yu Hsiao

    2014-11-01

    Full Text Available This paper is devoted to the analysis and design of high performance permanent-magnet synchronous wind generators (PSWGs. A systematic and sequential methodology for the design of PMSGs is proposed with a high performance wind generator as a design model. Aiming at high induced voltage, low harmonic distortion as well as high generator efficiency, optimal generator parameters such as pole-arc to pole-pitch ratio and stator-slot-shoes dimension, etc. are determined with the proposed technique using Maxwell 2-D, Matlab software and the Taguchi method. The proposed double three-phase and six-phase winding configurations, which consist of six windings in the stator, can provide evenly distributed current for versatile applications regarding the voltage and current demands for practical consideration. Specifically, windings are connected in series to increase the output voltage at low wind speed, and in parallel during high wind speed to generate electricity even when either one winding fails, thereby enhancing the reliability as well. A PMSG is designed and implemented based on the proposed method. When the simulation is performed with a 6 Ω load, the output power for the double three-phase winding and six-phase winding are correspondingly 10.64 and 11.13 kW. In addition, 24 Ω load experiments show that the efficiencies of double three-phase winding and six-phase winding are 96.56% and 98.54%, respectively, verifying the proposed high performance operation.

  18. Grid-connected wind and photovoltaic system

    Science.gov (United States)

    Devabakthuni, Sindhuja

    The objective of this thesis is to design a grid connected wind and photovoltaic system. A new model of converter control was designed which maintains the voltage of the bus to grid as constant when combined system of solar and wind is connected to AC bus. The model is designed to track maximum power at each point irrespective of changes in irradiance, temperature and wind speed which affects the power supplied to grid. Solar power from the sun is not constant as it is affected by changes in irradiances and temperature. Even the wind power is affected by wind speed. A MPPT controller was designed for both systems. A boost converter is designed which uses the pulses from MPPT controller to boost the output. Wind system consists of wind turbine block from the MATLAB with a pitch angle controller to maintain optimum pitch angle. The output from wind turbine is connected to a permanent magnet synchronous generator. The unregulated DC output from the photovoltaic system is directly given to boost converter. The AC output from the wind system is given to an uncontrolled rectifier to get a unregulated DC output. The unregulated DC output goes to the boost converter. A voltage source inverter was designed which converts the rectified DC output from the boost converter to AC power. The inverter is designed to maintain constant AC bus voltage irrespective of the disturbances in the power supply. Photovoltaic and wind systems are individually designed for 5KW each in MATLAB-Simulink environment. In this thesis, the models were subjected to changes in irradiance, temperature and wind speed and the results were interpreted. The model was successful in tracking maximum at every instant and the AC bus voltage was maintained constant throughout the simulation.

  19. Preliminary validation of RELAP5/Mod4.0 code for LBE cooled NACIE facility

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Indu; Khanna, Ashok, E-mail: akhanna@iitk.ac.in

    2017-04-01

    Highlights: • Detail discussion of thermo physical properties of Lead Bismuth Eutectic incorporated in the code RELAP5/Mod4.0 included. • Benchmarking of LBE properties in RELAP5/Mod4.0 against literature. • NACIE facility for three different power levels (10.8, 21.7 and 32.5 kW) under natural circulation considered for benchmarking. • Preliminary validation of the LBE properties against experimental data. • NACIE facility for power level 22.5 kW considered for validation. - Abstract: The one-dimensional thermal hydraulic computer code RELAP5 was developed for thermal hydraulic study of light water reactor as well as for nuclear research reactors. The purpose of this work is to evaluate the code RELAP5/Mod4.0 for analysis of research reactors. This paper consists of three major sections. The first section presents detailed discussions on thermo-physical properties of Lead Bismuth Eutectic (LBE) incorporated in RELAP5/Mod4.0 code. In the second section, benchmarking of RELAP5/Mod4.0 has been done with the Natural Circulation Experimental (NACIE) facility in comparison with Barone’s simulations using RELAP5/Mod3.3. Three different power levels (10.8 kW, 21.7 kW and 32.5 kW) under natural circulation conditions are considered. Results obtained for LBE temperatures, temperature difference across heat section, pin surface temperatures, mass flow rates and heat transfer coefficients in heat section heat exchanger are in agreement with Barone’s simulation results within 7% of average relative error. Third section presents validation of RELAP5/Mod4.0 against the experimental data of NACIE facility performed by Tarantino et al. test number 21 at power of 22.5 kW comparing the profiles of temperatures, mass flow rate and velocity of LBE. Simulation and experimental results agree within 7% of average relative error.

  20. Wind Spires as an Alternative Energy Source

    Energy Technology Data Exchange (ETDEWEB)

    Majid Rashidi, Ph.D., P.E.

    2012-10-30

    This report discloses the design and development of an innovative wind tower system having an axisymmetric wind deflecting structure with a plurality of symmetrically mounted rooftop size wind turbines near the axisymmetric structure. The purpose of the wind deflecting structure is to increase the ambient wind speed that in turn results in an overall increase in the power capacity of the wind turbines. Two working prototypes were constructed and installed in the summer of 2009 and 2012 respectively. The system installed in the Summer of 2009 has a cylindrical wind deflecting structure, while the tower installed in 2012 has a spiral-shape wind deflecting structure. Each tower has 4 turbines, each rated at 1.65 KW Name-Plate-Rating. Before fabricating the full-size prototypes, computational fluid dynamic (CFD) analyses and scaled-down table-top models were used to predict the performance of the full-scale models. The performance results obtained from the full-size prototypes validated the results obtained from the computational models and those of the scaled-down models. The second prototype (spiral configuration) showed at a wind speed of 11 miles per hour (4.9 m/s) the power output of the system could reach 1,288 watt, when a typical turbine installation, with no wind deflecting structure, could produce only 200 watt by the same turbines at the same wind speed. At a wind speed of 18 miles per hour (8 m/sec), the spiral prototype produces 6,143 watt, while the power generated by the same turbines would be 1,412 watt in the absence of a wind deflecting structure under the same wind speed. Four US patents were allowed, and are in print, as the results of this project (US 7,540,706, US 7,679,209, US 7,845,904, and US 8,002,516).

  1. 50 kW laser weapon demonstrator of Rheinmetall Waffe munition

    Science.gov (United States)

    Ludewigt, K.; Riesbeck, Th.; Graf, A.; Jung, M.

    2013-10-01

    We will present the setup of a 50 kW Laser Weapon Demonstrator (LWD) and results achieved with this system. The LWD is a ground based Air Defence system consisting of a Skyguard sensor unit for target acquisition and two laser equipped weapon turrets. The weapon turrets used are standard air defence turrets of Rheinmetall Air Defence which were equipped with several 10 kW Laser Weapon Modules (LWM). Each LWM consists of one 10 kW fiber laser and a beam forming unit (BFU). Commercial of the shelf fiber laser were modified for our defence applications. The BFU providing diffraction limited beam focusing, target imaging and fine tracking of the target was developed. The LWD was tested in a firing campaign at Rheinmetall test ground in Switzerland. All laser beams of both weapon turrets were superimposed on stationary and dynamic targets. Test results of the LWD for the scenarios Air Defence and C-RAMM (counter rockets, artillery, mortar and missiles) will be presented. An outlook for the next development stage towards a 100 kW class laser weapon on RWM will be given.

  2. Validation of an Aero-Acoustic Wind Turbine Noise Model Using Advanced Noise Source Measurements of a 500kW Turbine

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Fischer, Andreas

    2016-01-01

    rotor noise model is presented. It includes the main sources of aeroacoustic noise from wind turbines: turbulent inflow, trailing edge and stall noise. The noise measured by one microphone located directly downstream of the wind turbine is compared to the model predictions at the microphone location....... A good qualitative agreement is found. When wind speed increases, the rotor noise model shows that at high frequencies the stall noise becomes dominant. It also shows that turbulent inflow noise is dominant at low frequencies for all wind speeds and that trailing edge noise is dominant at low wind speeds...

  3. Large-scale wind energy and birds in Friesland: A survey of the possible hindrance for birds of the project Windstreek: Environmental Effect Report Windstreek, Base report A

    International Nuclear Information System (INIS)

    Van den Bergh, L.M.J.; Spaans, A.L.

    1994-01-01

    For several alternative sites in the Dutch province Friesland, where it is planned to install 500 kW and 1 MW wind turbines on a large scale (the Windstreek project), the possible hindrance for breeding birds, stopping birds and migratory birds has been investigated. First an overview is given of basic data from the literature and experts in the field with regard to the possible hindrances for birds and the situation of the birds in the areas considered. Next, several criteria are used to determine which locations are the most suitable sites for placing the wind turbines. For the 500 kW wind turbines (worst case) the suitability differs strongly per site. The variation is the largest for the option of decentralized sites. Realization of 200 MW large-scale generated wind power is the least unfavourable option, regarding the effects on birds, by means of decentralized sites. The super-structure option Afsluitdijk-Waddenkust and the Project Memorandum alternative are for that matter the least favourable options. The combined alternative and the super-structure Middelzeetrechter take the in-between position. The 1MW variants of the alternatives score better than the similar 500 kW options. The hindrance for birds can be reduced further by applying two-bladed rotors instead of three-bladed rotors and to adjust the site. 20 figs., 9 tabs., 2 appendices, 42 refs

  4. Proceedings of CanWEA's 2006 small wind conference

    International Nuclear Information System (INIS)

    2006-01-01

    Small wind energy systems are typically comprised of a single wind turbine for on-site power generation of between 300 watts to 100 kW. They are suited for use in remote locations, as well as on farms or for on-grid residential applications. Small wind customers are concerned about environmental issues as well as the reliability of the electric power grid. Recent increases in electricity prices have contributed to a renewed interest in small wind systems. Primary distributed wind market growth areas include residential grid-connected sites; schools, public facilities and farmer co-operatives; and farms, business and industry. Growth in small wind applications has not been matched by an increase in government incentives, and the lack of clear technical standards for wind systems may negatively impact public perceptions of the industry. This conference provided an overview of the small wind industry in Canada. The conference provided a forum for wind industry members, government agencies, and academics to explore challenges and barriers to the growth of the small wind industry. The conference, which was held as part of the larger annual CanWEA 2006 conference and trade show, was divided into 3 sessions: (1) policies to support small wind; (2) doing business with small wind; and (3) small wind technical insights. Recommendations for the certification of small wind turbines were provided, as well as a model zoning by-law. Technical issues included the development of high penetration wind/diesel systems for isolated communities in the Arctic; technical challenges with small turbines; and siting guidelines for consumers. Several small wind turbine owners reviewed some of the challenges of both buying and using wind systems. Technical and market barriers for distributed wind applications were also discussed. The conference featured 13 presentations, of which 12 were catalogued separately for inclusion in this database. refs., tabs., figs

  5. Applications of wind turbines in Canada

    Energy Technology Data Exchange (ETDEWEB)

    South, P; Rangi, R S; Templin, R J

    1977-01-01

    There are differing views as to the role of wind energy in the overall requirements. While some people tend to ignore it there are others who think that wind could be a major source of energy. In this paper an effort has been made to determine the wind power potential and also the amount that is economically usable. From the existing wind data a map showing the distribution of wind power density has been prepared. This map shows that the maritime provinces and the west coast of Hudson Bay have high wind power potential. These figures show that the wind power potential is of the same order as the installed electrical generating capacity in Canada (58 x 10/sup 6/kW in 1974). However, in order to determine how much of this power is usable the economics of adding wind energy to an existing system must be considered. A computer program has been developed at NRC to analyze the coupling of wind turbines with mixed power systems. Using this program and making certain assumptions about the cost of WECS and fuel the maximum amount of usable wind energy has been calculated. It is shown that if an installed capacity of 420 megawatts of wind power was added to the existing diesel capacity it would result in a savings of 60,000,000 gallons of fuel oil per year. On the other hand it is shown that if the existing installed hydro electric capacity of 37,000 megawatts (1976) was increased to 60,000 megawatts without increasing the average water flow rate, an installed capacity of 60,000 megawatts of wind power could be added to the system. This would result in an average of 14,000 megawatts from the wind. Using projected manufacturing costs for vertical axis wind turbines, the average cost of wind energy could be in the range of 1.4 cents/kwh to 3.6 cents/kwh.

  6. Environmental studies related to the operation of wind energy conversion systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, S.E.; Cornaby, B.W.; Rodman, C.W.; Sticksel, P.R.; Tolle, D.A.

    1977-12-01

    This biophysical impact assessment explores the environmental consequences of the emerging wind energy conversion technology through field studies done at the DOE/NASA 100-kW Experimental Wind Turbine located at NASA Lewis Research Center's Plum Brook Station near Sandusky, Ohio. A micrometeorological field program monitored changes in the downwind wake of the wind turbine. Horizontal and/or vertical measurements of wind speed, temperature, carbon dioxide concentration, precipitation, and incident solar radiation showed measurable variation within the wake only for precipitation and wind speed. The changes were minor and not likely to result in any secondary effects to vegetation, including crops, because they are within the natural range of variability in the site environment. Effects are negligible beyond the physically altered area of the tower pad, access, and control structures. The wind turbine has not proved to be a high risk to airborne fauna, including the most vulnerable night-migrating songbirds. Behavioral studies indicate the birds will avoid the turbine if they can see it.

  7. Blade design and operating experience on the MOD-OA 200 kW wind turbine at Clayton, New Mexico

    Science.gov (United States)

    Linscott, B. S.; Shaltens, R. K.

    1979-01-01

    Two 60 foot long aluminum wind turbine blades were operated for over 3000 hours on the MOD-OA wind turbine. The first signs of blade structural damage were observed after 400 hours of operation. Details of the blade design, loads, cost, structural damage, and repair are discussed.

  8. Electric propulsion options for 10 kW class earth space missions

    Science.gov (United States)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment have been evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA II 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10(7) to 2.1x10(7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA II 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10(6) to 3.6x10(6) N-s, and approximately 662 to 1072 m/s, respectively.

  9. Electric Propulsion Options for 10 kW Class Earth-Space Missions

    Science.gov (United States)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment were evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA 2 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10 (exp 7) to 2.1x10 (exp 7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA 2 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10 (exp 6) to 3.6x10 (exp 6) N-s, and approximately 662 to 1072 m/s, respectively.

  10. Wind energy potential in Chile: Assessment of a small scale wind farm for residential clients

    International Nuclear Information System (INIS)

    Becerra, Miguel; Morán, José; Jerez, Alejandro; Cepeda, Francisco; Valenzuela, Miguel

    2017-01-01

    Highlights: • An assessment of a small scale wind farm was carried out. • Two Chilean locations were selected, which are geographically dissimilar. • The software tool selected for the project’s evaluation was HOMER. • All the project’s financial evaluations were negative. • Government policy tools and their applications were discussed. - Abstract: This work presents a techno-financial evaluation of two Chilean locations with promising wind potential: Laguna Verde placed in the central region of the country, and Porvenir in the southern region. A small scale wind farm was studied, considering a nominal electrical production capacity of 90 kW. This facility is comprised of three wind turbine models, all available in the national market. Currently, the tariff method used in Chile is the net billing scheme, where the energy bought and sold to the grid has different prices. The study is based on 300 hypothetical residential households. The software tool used to perform the assessment was the Hybrid Optimization of Multiple Energy Resources (HOMER). For all the scenarios the results showed a Net Present Cost (NPC), instead of a financial profit from the proposed projects. A sensitivity analysis was also carried out. From the group of variables studied, the NPC exhibited itself as more sensitive to the price of buying energy from the grid and to the annual average wind speed. Finally, a few government policies and their applications are discussed.

  11. Danish wind turbines: Technical-economic feasibility of commercial models

    International Nuclear Information System (INIS)

    Falchetta, M.

    1992-01-01

    This feasibility study examines the principal technical and economic (investment-manufacturing-installation-operation unit costs, supply and demand) characteristics of wind turbines being commercialized in Denmark. The general configuration of the 150 to 450 kW range machines currently being manufactured can be described as that of a three bladed fibreglass rotor, of from 24 to 35 meters in diameter, and mounted on a tower of from 29 to 41 meters in height. The electrical system consists of one asynchronous generator or a two generator system with a power ratio of 1 to 5 between the two generators. The cost analysis reveals that the Danish wind turbines are competitively priced, with per kWh costs varying from $0. 0675 to $0. 040 for operating wind speeds ranging from 5 to 7 m/sec, and that their overall design and performance characteristics make them suitable for Italian site conditions

  12. Experiences from the operation of a wind-hydrogen pilot unit

    International Nuclear Information System (INIS)

    Varkaraki, E.; Lymberopoulos, N.; Zoulias, E.; Kalyvas, E.; Christodoulou, C.; Karagiorgis, G.

    2006-01-01

    A pilot wind-hydrogen system has been erected and tested at the wind park of the Centre for Renewable Energy Sources, near Athens, Greece, composed of an alkaline water electrolyser, metal hydride tanks for long term storage and a hydrogen compressor for filling high pressure hydrogen cylinders. The 25 kW electrolyser produces 0.45 kg/h hydrogen under 20 bar pressure, which may be compressed up to 220 bar in one stage. A small conventional tank acts as hydrogen buffer to smooth the pressure and flow variations at the compressor inlet. The metal hydride tanks have a storage capacity of 3.6 kg hydrogen and contain a LaNi5-type alloy. The preliminary results show that the hydrogen system has an overall efficiency of 58%, considering the electrical power of the wind turbine consumed by the whole plant, including utilities. (authors)

  13. Operation Design of Wind Turbines in Strong Wind Conditions

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Montes, Melissa Barroso; Odgaard, Peter Fogh

    2012-01-01

    and variable speed pitch regulated wind turbines. The variable speed design is more suitable for wind turbines to run at very high wind speeds which can help the turbine braking system to stop the turbine at the new "cut-out" wind speed. Reference power, rotational speed and pitch angle have been designed...... optimally. In order to reduce the possible increased loading, fatigue due to the wind gusts, control strategies have been considered for both constant sped and variable speed pitch regulated wind turbines. The control study shows that the designed controllers can reduce the standard deviations efficiently......In order to reduce the impact on the electrical grid from the shutdown of MW wind turbines at wind speeds higher than the cut-out wind speed of 25 m/s, we propose in this paper to run the turbines at high wind speeds up to 40 m/s. Two different operation designs are made for both constant speed...

  14. Hydrogen production from wind energy in Western Canada for upgrading bitumen from oil sands

    International Nuclear Information System (INIS)

    Olateju, Babatunde; Kumar, Amit

    2011-01-01

    Hydrogen is produced via steam methane reforming (SMR) for bitumen upgrading which results in significant greenhouse gas (GHG) emissions. Wind energy based hydrogen can reduce the GHG footprint of the bitumen upgrading industry. This paper is aimed at developing a detailed data-intensive techno-economic model for assessment of hydrogen production from wind energy via the electrolysis of water. The proposed wind/hydrogen plant is based on an expansion of an existing wind farm with unit wind turbine size of 1.8 MW and with a dual functionality of hydrogen production and electricity generation. An electrolyser size of 240 kW (50 Nm 3 H 2 /h) and 360 kW (90 Nm 3 H 2 /h) proved to be the optimal sizes for constant and variable flow rate electrolysers, respectively. The electrolyser sizes aforementioned yielded a minimum hydrogen production price at base case conditions of $10.15/kg H 2 and $7.55/kg H 2 . The inclusion of a Feed-in-Tariff (FIT) of $0.13/kWh renders the production price of hydrogen equal to SMR i.e. $0.96/kg H 2, with an internal rate of return (IRR) of 24%. The minimum hydrogen delivery cost was $4.96/kg H 2 at base case conditions. The life cycle CO 2 emissions is 6.35 kg CO 2 /kg H 2 including hydrogen delivery to the upgrader via compressed gas trucks. -- Highlights: ► This study involves development of a data intensive techno-economic model for estimation cost of hydrogen production from wind energy. ► Wind energy based electricity is used for electrolysis to produce hydrogen in Western Canada for bitumen upgrading for oil sands. ► Several scenarios were developed to study the electricity generation and hydrogen production from wind energy. ► The cost of production of hydrogen is significantly higher than natural based hydrogen in Western Canada.

  15. The VolturnUS 1:8 Floating Wind Turbine: Design, Construction, Deployment, Testing, Retrieval, and Inspection of the First Grid-Connected Offshore Wind Turbine in US

    Energy Technology Data Exchange (ETDEWEB)

    Dagher, Habib [Univ. of Maine, Orono, ME (United States); Viselli, Anthony [Univ. of Maine, Orono, ME (United States); Goupee, Andrew [Univ. of Maine, Orono, ME (United States); Kimball, Richard [Maine Maritime Academy, Castine, ME (United States); Allen, Christopher [Univ. of Maine, Orono, ME (United States)

    2017-08-15

    Volume II of the Final Report for the DeepCwind Consortium National Research Program funded by US Department of Energy Award Number: DE-EE0003278.001 summarizes the design, construction, deployment, testing, numerical model validation, retrieval, and post-deployment inspection of the VolturnUS 1:8-scale floating wind turbine prototype deployed off Castine, Maine on June 2nd, 2013. The 1:8 scale VolturnUS design served as a de-risking exercise for a commercial multi-MW VolturnUS design. The American Bureau of Shipping Guide for Building and Classing Floating Offshore Wind Turbine Installations was used to design the prototype. The same analysis methods, design methods, construction techniques, deployment methods, mooring, and anchoring planned for full-scale were used. A commercial 20kW grid-connected turbine was used and was the first offshore wind turbine in the US.

  16. Technology for the Sound of Music

    Science.gov (United States)

    1994-01-01

    In the early 1960s during an industry recession, Kaman Aircraft lost several defense contracts. Forced to diversify, the helicopter manufacturer began to manufacture acoustic guitars. Kaman's engineers used special vibration analysis equipment based on aerospace technology. While a helicopter's rotor system is highly susceptible to vibration, which must be reduced or "dampened," vibration enhances a guitar's sound. After two years of vibration analysis Kaman produced an instrument, which is very successful. The Ovation guitar is made of fiberglass. It is stronger than the traditional rosewood and manufactured with adapted aircraft techniques such as jigs and fixtures, reducing labor and assuring quality and cost control. Kaman Music Corporation now has annual sales of $100 million.

  17. A Review of Research on Large Scale Modern Vertical Axis Wind Turbines at Uppsala University

    Directory of Open Access Journals (Sweden)

    Senad Apelfröjd

    2016-07-01

    Full Text Available This paper presents a review of over a decade of research on Vertical Axis Wind Turbines (VAWTs conducted at Uppsala University. The paper presents, among others, an overview of the 200 kW VAWT located in Falkenberg, Sweden, as well as a description of the work done on the 12 kW prototype VAWT in Marsta, Sweden. Several key aspects have been tested and successfully demonstrated at our two experimental research sites. The effort of the VAWT research has been aimed at developing a robust large scale VAWT technology based on an electrical control system with a direct driven energy converter. This approach allows for a simplification where most or all of the control of the turbines can be managed by the electrical converter system, reducing investment cost and need for maintenance. The concept features an H-rotor that is omnidirectional in regards to wind direction, meaning that it can extract energy from all wind directions without the need for a yaw system. The turbine is connected to a direct driven permanent magnet synchronous generator (PMSG, located at ground level, that is specifically developed to control and extract power from the turbine. The research is ongoing and aims for a multi-megawatt VAWT in the near future.

  18. Active control: Wind turbine model

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, Henrik

    1999-07-01

    This report is a part of the reporting of the work done in the project `Active Control of Wind Turbines`. This project aim is to develop a simulation model for design of control systems for turbines with pitch control and to use that model to design controllers. This report describes the model developed for controller design and analysis. Emphasis has been put on establishment of simple models describing the dynamic behavior of the wind turbine in adequate details for controller design. This has been done with extensive use of measurements as the basis for selection of model complexity and model validation as well as parameter estimation. The model includes a simple model of the structure of the turbine including tower and flapwise blade bending, a detailed model of the gear box and induction generator, a linearized aerodynamic model including modelling of induction lag and actuator and sensor models. The models are all formulated as linear differential equations. The models are validated through comparisons with measurements performed on a Vestas WD 34 400 kW wind turbine. It is shown from a control point of view simple linear models can be used to describe the dynamic behavior of a pitch controlled wind turbine. The model and the measurements corresponds well in the relevant frequency range. The developed model is therefore applicable for controller design. (au) EFP-91. 18 ills., 22 refs.

  19. Small wind turbine purchasing guide : off-grid, residential, farm and small business applications

    International Nuclear Information System (INIS)

    2008-11-01

    Consumer interest in the environment and the economic advantages of using wind power are now driving interest in smaller wind turbines that range from micro battery-charging models to 300 kW tower-mounted turbines. Smaller turbines are also becoming increasingly accessible through major retail outlets. This guide discussed basic issues surrounding the purchasing, selection and installation of smaller wind turbines. Guidance related to site selection, permitting and approvals was provided, as well as recommendations related to maintenance and system performance. Information related to compliance, safety and setback and zoning restrictions was also presented. The guide was divided into 5 chapters: (1) an introduction to small wind turbines, (2) assessing site-specific expectations, (3) purchasing and permitting, (4) installation, operation and maintenance, and (6) a permitting checklist for small wind customers. Financial incentives for defraying the capital costs of small wind turbines were discussed, and guidance for determining electrical requirements was also provided. A glossary was included, as well as a list of local wind energy contractor and dealers. 3 tabs., 10 figs

  20. A 3 MW wind power plant at Maglarp in Sweden

    International Nuclear Information System (INIS)

    Koc, B.

    1991-01-01

    The wind power plant at Maglarp, in a frequented region of Sweden, is described. Its technical parameters are given and its environmental impacts are dealt with. The whiz of the rotor blades is heard at a distance of 500 to 1000 m; the author refers to the whiz as pleasant. Not a single bird has been found killed by the facility. Interference with the TV signal can at times be observed in the town; this is more marked with metal rotor blades than with blades made of reinforced plastic. A wing of the wind power plant concentrates on its surface an energy of about 20 kW per square meter. (M.D.)

  1. Wind energy - The facts. Vol. 3: Industry and employment

    International Nuclear Information System (INIS)

    Jacobsen, Henrik

    2004-01-01

    Since the last Wind Energy - The Facts report published in 1999, the European wind energy industry has made significant progress. There are several ways of monitoring this progress, such as measuring electricity output in MW or kW hours. However, the usual method is to use a measurement of installed capacity, so this chapter demonstrates national markets and their growth in terms of MW capacity installed. Wind experienced a surge of growth in California in the 1980s thanks to a combination of state and federal energy and investment tax credits. From 1980 to 1995, around 1,700 MW of wind capacity was installed and, although there were some turbines of poorer quality, the boom period provided a major export market for European manufacturers, and did much to establish the credibility of the industry. Since then, Europe has turned the tables and consolidated its position as the global market leader. Within Europe, certain countries are particularly strong: the top five in terms of installed capacity being Germany, Spain, Denmark, The Netherlands and Italy. (au)

  2. Engineering and erection of a 300kW high-flux solar simulator

    Science.gov (United States)

    Wieghardt, Kai; Laaber, Dmitrij; Hilger, Patrick; Dohmen, Volkmar; Funken, Karl-Heinz; Hoffschmidt, Bernhard

    2017-06-01

    German Aerospace Center (DLR) is currently constructing a new high-flux solar simulator synlight which shall be commissioned in late 2016. The new facility will provide three separately operated experimental spaces with expected radiant powers of about 300kW / 240kW / 240kW respectively. synlight was presented to the public for the first time at SolarPACES 2015 [1]. Its engineering and erection is running according to plan. The current presentation reports about the engineering and the ongoing erection of the novel facility, and gives an outlook on its new level of possibilities for solar testing and qualification.

  3. Wind: small is beautiful

    International Nuclear Information System (INIS)

    Vries, E. de

    2005-01-01

    The small wind sector (0.5-100 kW) is often overlooked but could provide decentralised energy systems. Small wind turbines have been used for homes, farms and small businesses for over 80 years (e.g. in the USA and the Netherlands), receiving a boost in the 1970s and 1980s following the 1973 oil crisis when a new generation of turbines entered the European and US markets. Bergey Windpower and Southwest Windpower from the USA are the market leaders in this sector in terms of sales volume but are still classed as medium-sized enterprises. Small turbines have the disadvantage of higher costs compared with large turbines due to higher manufacturing costs, technical factors associated with the tendency to use small turbines on relatively short towers, small production runs and a failure to keep up with the latest design developments such as cost-effective state-of-the-art frequency converters. Most small turbines are horizontal axis turbines, though vertical axis turbines are produced by some manufacturers. Examples of the systems available from European suppliers are described

  4. Comparison of wind turbines based on power curve analysis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    In the study measured power curves for 46 wind turbines were analyzed with the purpose to establish the basis for a consistent comparison of the efficiency of the wind turbines. Emphasis is on wind turbines above 500 kW rated power, with power curves measured after 1994 according to international recommendations. The available power curves fulfilling these requirements were smoothened according to a procedure developed for the purpose in such a way that the smoothened power curves are equally representative as the measured curves. The resulting smoothened power curves are presented in a standardized format for the subsequent processing. Using wind turbine data from the power curve documentation the analysis results in curves for specific energy production (kWh/M{sup 2}/yr) versus specific rotor load (kW/M{sup 2}) for a range of mean wind speeds. On this basis generalized curves for specific annual energy production versus specific rotor load are established for a number of generalized wind turbine concepts. The 46 smoothened standardized power curves presented in the report, the procedure developed to establish them, and the results of the analysis based on them aim at providers of measured power curves as well as users of them including manufacturers, advisors and decision makers. (au)

  5. Airloads Correlation of the UH-60A Rotor inside the 40- by 80-Foot Wind Tunnel

    Directory of Open Access Journals (Sweden)

    I-Chung Chang

    2014-01-01

    Full Text Available The presented research validates the capability of a loosely coupled computational fluid dynamics (CFD and comprehensive rotorcraft analysis (CRA code to calculate the flowfield around a rotor and test stand mounted inside a wind tunnel. The CFD/CRA predictions for the Full-Scale UH-60A Airloads Rotor inside the National Full-Scale Aerodynamics Complex (NFAC 40- by 80-Foot Wind Tunnel at NASA Ames Research Center are compared with the latest measured airloads and performance data. The studied conditions include a speed sweep at constant lift up to an advance ratio of 0.4 and a thrust sweep at constant speed up to and including stall. For the speed sweep, wind tunnel modeling becomes important at advance ratios greater than 0.37 and test stand modeling becomes increasingly important as the advance ratio increases. For the thrust sweep, both the wind tunnel and test stand modeling become important as the rotor approaches stall. Despite the beneficial effects of modeling the wind tunnel and test stand, the new models do not completely resolve the current airload discrepancies between prediction and experiment.

  6. Measurement of the environmental noise at the Torseroed wind turbine site

    International Nuclear Information System (INIS)

    Fegeant, Olivier

    2000-12-01

    Further to complaints about the noise generated by a Micon 600 kW wind turbine, measurements of both noise immission and noise emission were performed at the Torseroed site. The measurements and analysis presented in this report were carried out by following the recommendations of the IEA documents for noise emission and immission measurements. It was found that the immission level, i.e. the wind turbine sound, at one of the nearest dwelling, namely Solglaentan, is 39 dB(A) for a wind speed of 8 m/s at hub height. Measurements carried out close to the turbine show that the sound power level of the turbine is 4.3 dB higher than the A-weighted level given by the supplier. Furthermore, the noise level increases more rapidly as a function of the wind speed than what is expected from the values furnished by the manufacturer. The measurements results also show that the background noise level is unusually low at Solglaentan

  7. Towards mass-market development of wind energy

    International Nuclear Information System (INIS)

    Palz, W.

    1996-01-01

    The wind turbine technologies employed in today's markets for wind energy are innovative, efficient and in many cases cost competitive. A world market of more than 1000 MW/year and with a turnover of 1 billion ECU has developed and 30,000 new jobs have been created, most of them in small and medium size enterprises. 80% of today's world production is European. The preferred turbine capacity of today is 500 kW. In the next few years a three-fold increase in the rated power of most commercial machines to 1.5 MW is expected. The new large machines have been achieved through the ''WEGA''-programme of the European Commission. Significant market penetration of wind power in the European Union is very recent. The 2500 MW installed wind capacity in Europe today accounts only for 1/2% of the total capacity available for electricity production. Markets of the future will depend on a better development of the economic integration issues of wind energy into large networks. A key is the cost of electric grids which conditions the opportunity cost for feeding wind power at any particular point into the grids. Also, better predictability of the wind resource will give higher value to wind power in the grid and improve its economics further. Various financing schemes have been set up throughout Europe. Financial support and incentives are vital for some more years to come to expand current markets and improve economics through economy of scale. The utilisation of wind turbines in off-grid situations is an important new field for technological innovations and deployment. (author)

  8. Calculation and design of steel bearing structure for wind turbine

    Directory of Open Access Journals (Sweden)

    Bešević Miroslav

    2014-01-01

    Full Text Available Wind represents directed movement of the air and is caused by differences in atmospheric pressure which are caused by uneven heating of air masses. Global and local winds can be distinguished. Global winds have high altitude, while local winds occur in the ground layer of the atmosphere. Given that the global wings have high altitude they cannot be used as propellant for wind generators, but they should be known for their effects on the winds in the lower atmosphere. Modern wind turbines are made with a horizontal axle that has a system for the swiveling axis in the horizontal plane for tracking wind direction changes. They can have different number of blades, but for larger forces three blades are commonly used because they provide the greatest efficiency. Rotor diameter of these turbines depends on the strength and it ranges from 30 m for the power of 300 kW to 115 m for the power of 5 MW. Wind turbines are mounted on vertical steel tower which can be high even more than 100 m. Depending on the diameter of the turbine rotor, column is usually built as steel conical and less often as a steel-frame. This study includes analysis and design of steel tower for wind generator made by manufacturer Vestas, type V112 3MW HH 119 (power 3.2 MW for the construction of wind farm 'Kovačica'.

  9. Efficient pump module coupling >1kW from a compact detachable fiber

    Science.gov (United States)

    Dogan, M.; Chin, R. H.; Fulghum, S.; Jacob, J. H.; Chin, A. K.

    2018-02-01

    In the most developed fiber amplifiers, optical pump power is introduced into the 400μm-diameter, 0.46NA first cladding of the double-clad, Yb-doped, gain fiber, using a (6+1):1 multi-mode fiber combiner. For this configuration, the core diameter and numerical aperture of the pump delivery fibers have maximum values of 225μm and 0.22, respectively. This paper presents the first fiber-coupled laser-diode pump module emitting more than 1kW of claddingmode- stripped power from a detachable 225μm, 0.22NA delivery fiber at 976nm. The electrical-to-optical power conversion efficiency at 1kW is 50%. The FWHM spectral width at 1kW output is 4nm and has an excellent overlap with the narrow absorption spectrum of ytterbium in glass. Six of these pump modules attached to a (6+1):1 multimode combiner enable a 5-6kW, single-mode, Yb-doped fiber amplifier.

  10. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A.; Campos, J. [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A. [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1997-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  11. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A; Campos, J [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1998-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  12. Fiscal 1998 achievement report on regional consortium research and development project. Venture business raising type regional consortium - small business creating base type (Development of mobile hybrid power source system using wind and solar energies); 1998 nendo kahanshiki furyoku taiyoko hybrid dengen system no kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-01

    Regarding new energy power sources such as solar cells and small wind power systems (1-3kW), research and development is conducted for a new hybrid system featuring 'mobile, package type, no construction cost.' In the research, 4-12m telescopic wind turbine supporting poles are manufactured for two types of wind turbines respectively generating 1.5kW and 2.5kW. A slide type mechanism is employed for solar cell deployment, which enables on-site deployment. Each solar panel accommodates 24 solar cells, and one is installed on top of a container to serve as control room. A control system is developed for this hybrid power source system, which receives power from a wind power turbine and solar cells and supplies power to three kinds of power sources. For the stable supply of power to the loads, 24V/1500Ah batteries are provided. Each power charging controller and protecting device are found to operate smoothly in a verification test, which means the goal of the development endeavors has been achieved. (NEDO)

  13. Power control for direct-driven permanent magnet wind generator system with battery storage.

    Science.gov (United States)

    Guang, Chu Xiao; Ying, Kong

    2014-01-01

    The objective of this paper is to construct a wind generator system (WGS) loss model that addresses the loss of the wind turbine and the generator. It aims to optimize the maximum effective output power and turbine speed. Given that the wind generator system has inertia and is nonlinear, the dynamic model of the wind generator system takes the advantage of the duty of the Buck converter and employs feedback linearization to design the optimized turbine speed tracking controller and the load power controller. According to that, this paper proposes a dual-mode dynamic coordination strategy based on the auxiliary load to reduce the influence of mode conversion on the lifetime of the battery. Optimized speed and power rapid tracking as well as the reduction of redundant power during mode conversion have gone through the test based on a 5 kW wind generator system test platform. The generator output power as the capture target has also been proved to be efficient.

  14. Bird casualties and wind turbines near the Kreekrak sluices of Zeeland

    International Nuclear Information System (INIS)

    Musters, C.J.M.; Noordervliet, M.A.W.; Ter Keurs, W.J.

    1995-03-01

    The impact of wind turbines on birds was investigated for an estuary, situated near the North Sea coast in the Dutch province of Zeeland, with large amount of bird migration. Five 250 kW, three-bladed 25m, 40 rpm turbines were installed on the western side of a dike. The distance between the turbines is 125 m. Since 1 April 1990 the turbines have been in action almost continuously. The study on the title subject was set up to investigate the number of bird casualties caused by the five wind turbines near the sluices of Kreekrak and the number that may be expected to be caused by a total of 20 turbines. The study also focused on the number of casualties among rare birds in relation to those among the common birds as a result of the wind turbines in the Kreekrak area. An area of 125 x 125 m around each wind turbine, consisting partly of land and partly of water, was searched for dead birds every other day during a period of one year (28 April 1990 - 29 April 1991). During this one-year period, the bodies of 26 birds of 17 different species were found; six birds were certainly or almost certainly killed by the turbines. In three other cases, the birds may have died because of the turbines, while in the case of eight birds, it was not possible to determine the cause of death. The remaining nine birds were not killed by the wind turbines. The annual number of bird victims expected following the installation of 20 wind turbines was estimated at a minimum of 7 and a maximum of 142. For each species a correlation was found between the number of victims and the estimated number of visitors to the area. This suggests that the rare species among the birds were not excessively endangered by the turbines. The number of bird casualties per turbine was low in comparison with the results of other Dutch investigations. On the basis of these results, it is concluded that there is no reason to advise against increasing the number of wind turbines near the sluices of Kreekrak to 20. 3

  15. Report on field test project for wind power development at Nagashima-cho. Detailed wind characteristics survey; Nagashimacho ni okeru furyoku field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    A detailed wind characteristics survey was conducted to study the feasibility of a wind power generation system for Nagashima-cho, Izumi-gun, Kagoshima Prefecture. Observation instruments were installed at the top of a hill approximately 80m above the sea level situated to the northwest of the Nagashima-cho town hall and, in the period October 1998 through September 1999, data were collected at a point 20m above ground, such as the average wind speed and direction, wind velocity standard deviation, and the maximum instantaneous wind velocity. The data were analyzed, and findings were obtained, as mentioned below. The annual average wind speed was 5.0m, strong in winter and weak in summer. The annual wind direction occurrence rate was 61.8%, turbulence intensity was 0.17 at wind speeds of 4m/s and more, these not presenting any particular problem. Wind energy density was 148W/m{sup 2}. Both wind speed conditions and energy density were slightly lower than the reference levels indicated for evaluation. Studies were made on the assumption that three classes of wind turbines (150, 300, and 750kW) would be introduced, and then it was found that both operating factors and facility availability rates exceeded the required levels. Since there were no detrimental factors in the surrounding conditions, it was concluded that possibilities were high that wind power generation at the site would be practical. (NEDO)

  16. Coupling of a 2.5 kW steam reformer with a 1 kW el PEM fuel cell

    Science.gov (United States)

    Mathiak, J.; Heinzel, A.; Roes, J.; Kalk, Th.; Kraus, H.; Brandt, H.

    The University of Duisburg-Essen has developed a compact multi-fuel steam reformer suitable for natural gas, propane and butane. This steam reformer was combined with a polymer electrolyte membrane fuel cell (PEM FC) and a system test of the process chain was performed. The fuel processor comprises a prereformer step, a primary reformer, water gas shift reactors, a steam generator, internal heat exchangers in order to achieve an optimised heat integration and an external burner for heat supply as well as a preferential oxidation step (PROX) as CO purification. The fuel processor is designed to deliver a thermal hydrogen power output from 500 W to 2.5 kW. The PEM fuel cell stack provides about 1 kW electrical power. In the following paper experimental results of measurements of the single components PEM fuel cell and fuel processor as well as results of the coupling of both to form a process chain are presented.

  17. Indices for planning wind power generation; Furyoku hatsuden no keikaku shihyo

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, H

    1997-11-25

    Outlined herein are status of wind power generation development, indices for planning development, and actual development results. At present, wind power generates electric power of 6,781MW worldwide. USA has been rapidly developing wind power generation since enactment of the PURPA law, and accounted for 25% of the world output in the past. However, the county is recently unseated from the world top position by Germany, which has been extensively developing wind power generation since enactment of the EFL law to reach 1,799MW. In Japan, electric power companies, local governments and public institutions have been positively introducing wind mills since 1992, when Tohoku Electric Power Co. built Ryuhi Wind Park, now generating a total power of 15MW by 64 units located at 33 different points. According to the surveys by NEDO on wind conditions, there are a number of districts suited for wind mills in Hokkaido, Tohoku, Okinawa and sea areas in Honshu. The indices described herein for planning wind power generation include rotor diameter, tower height, speed of rotation, weight, power to be generated, utilization and service factors, noise level, and investment and running costs. In the present state of the development of wind power generation in Japan, development points are 33, generated ouptut 15,097kW and units 64. 14 figs.

  18. Faroe Islands Wind-Powered Space Heating Microgrid Using Self-Excited 220 kW Induction Generator

    DEFF Research Database (Denmark)

    Thomsen, Bjarti; Guerrero, Josep M.; Thogersen, Paul

    2014-01-01

    its own control of frequency and voltage. A micro-controller is used to control frequency by matching load (heaters) to generated power and to produce the correct reactive power and voltage by switched capacitors. One challenge is the startup procedure at high winds speeds when nominal speed tend...

  19. Evaluation of a small-scale wind power plant; Utvaerdering av smaaskaligt vindkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    Arvidsson, Ulf; Hilding, Sten [Elforsk AB, Stockholm (Sweden)

    2001-12-01

    The aim of this work is to evaluate the electrical performance of the 20 kW Pitch Wind turbine. The work was originally intended to focus on evaluating the first machine in a series of three, which should be a machine ready for series production. However, the control system of the machine was not tested and verified so instead a large part of the work has been to check that the electrical system and the control system operates as intended and to adjust and suggest improvements. The design includes a self-regulating variable speed wind turbine coupled to a permanent magnet generator and a converter.

  20. Super wind turbine park upon a dike in the Zuiderzeepolder

    Energy Technology Data Exchange (ETDEWEB)

    Buma, J T; Cuypers, H S; Berkhuizen, J C

    1986-12-01

    A wind turbine park has been planned near Urk, formerly an island in the Zuiderzee, and now a location in the IJsselmeerpolders. The project covers the erection of 25 wind turbines of 300 kW each. A short description of the foundations and construction is given. Turbines will be supplied by Hayen Maurice Zepperen in Belgium and the rotors by Stork, Venlo, Netherlands. Rotors will consist of three adjustable blades made of glass reinforced polyester. Yawing will be controlled automatically by a central windvane. There are no safety standards in The Netherlands yet for wind turbines with diameters larger than 20 m, but these turbines are expected to be safe. A number of factors which may produce difficulties are mentioned (noise, accidents, landscape pollution, danger for passing birds). There is also a real danger for damage caused by drifting ice. Finally, the economic and financial factors are discussed.

  1. Full scale testing for investigation of wind turbine seismic response

    Energy Technology Data Exchange (ETDEWEB)

    Prowell, I.; Veletzos, M.; Elgamal, A. [California Univ., San Diego, CA (United States). Dept. of Structural Engineering

    2008-07-01

    In 2007, much of the growth in wind energy development was concentrated in North America and Asia, two regions which periodically experience strong earthquakes that may impact the final turbine design. As such, rational prediction of seismic hazards must be considered in order to maintain and enhance the ability of wind power to compete economically with other energy sources. In response to this challenge, researchers at the University of California, San Diego (UCSD) have experimentally investigated wind turbines to gain an understanding of expected earthquake forces. This paper described the experimental setup for a full scale shake table test of a 65 kW wind turbine. The turbine was excited perpendicular to the axis of the rotor with a seismic base shaking record scaled to various levels. The data was analyzed using simple but effective procedures to provide insight into the observed structural damping of the wind turbine. The experimental investigation showed that full scale seismic testing of wind turbines is possible and can provide valuable insight into dynamic behaviour of wind turbines. The results can be used to develop a more accurate picture of how wind turbines are impacted by earthquakes. The data regarding the low observed super-structure damping provides a basis for calibration and further development of verified design procedures. 20 refs., 3 tabs.

  2. The effect of the Sep wind park near Oosterbierum, Friesland, The Netherlands, on birds

    International Nuclear Information System (INIS)

    Winkelman, J.E.

    1992-01-01

    The title study concerns the period 1984-1991. The wind park consists of 18 three-bladed 300 kW horizontal axis wind turbines of 35 meters height, and a rotor diameter of 30 meters, seven meteorological towers, and three cluster and control buildings. Aspects studied included disturbance of breeding, resting or feeding, and migrating birds, behavior of birds approaching the wind turbines during the day and night, and bird victims due to collision with the wind turbines and the meteorological towers. In this report data on the number of birds passing the wind park at night and the flight behavior of these birds during their passage are presented and discussed. The numbers were determined in the period 1985-1988 by using a search approach radar, two passive image intensifiers in combination with infrared spot lights, and a thermal image intensifier. Illumination of the wind turbines to avoid collisions is not believed to be necessary, because birds seem to be quite good at spotting the wind turbines, even during conditions of moderate visibility at night. 30 figs., 23 tabs., 18 app., 109 refs

  3. Wind farm production cost: Optimum turbine size and farm capacity in the actual market

    Energy Technology Data Exchange (ETDEWEB)

    Laali, A.R.; Meyer, J.L.; Bellot, C. [Electricite de France, Chatou (France); Louche, A. [Espace de Recherche, Ajaccio (France)

    1996-12-31

    Several studies are undertaken in R&D Division of EDF in collaboration with ERASME association in order to have a good knowledge of the wind energy production costs. These studies are performed in the framework of a wind energy monitoring project and concern the influence of a few parameters like wind farm capacity, turbine size and wind speed on production costs, through an analysis of the actual market trend. Some 50 manufacturers and 140 different kind of wind turbines are considered for this study. The minimum production cost is situated at 800/900 kW wind turbine rated power. This point will probably move to more important powers in the future. This study is valid only for average conditions and some special parameters like particular climate conditions or lack of infrastructure for a special site the could modify the results shown on the curves. The variety of wind turbines (rated power as a function of rotor diameter, height and specific rated power) in the actual market is analyzed. A brief analysis of the market trend is also performed. 7 refs., 7 figs.

  4. Efficient 10 kW diode-pumped Nd:YAG rod laser

    Science.gov (United States)

    Akiyama, Yasuhiro; Takada, Hiroyuki; Sasaki, Mitsuo; Yuasa, Hiroshi; Nishida, Naoto

    2003-03-01

    As a tool for high speed and high precision material processing such as cutting and welding, we developed a rod-type all-solid-state laser with an average power of more than 10 kW, an electrical-optical efficiency of more than 20%, and a laser head volume of less than 0.05 m3. We developed a highly efficient diode pumped module, and successfully obtained electrical-optical efficiencies of 22% in CW operation and 26% in QCW operation at multi-kW output powers. We also succeeded to reduce the laser head volume, and obtained the output power of 12 kW with an efficiency of 23%, and laser head volume of 0.045 m3. We transferred the technology to SHIBAURA mechatronics corp., who started to provide the LD pumped Nd:YAG laser system with output power up to 4.5 kW. We are now continuing development for further high power laser equipment.

  5. 1000 Hours of Testing Completed on 10-kW Hall Thruster

    Science.gov (United States)

    Mason, Lee S.

    2001-01-01

    Between the months of April and August 2000, a 10-kW Hall effect thruster, designated T- 220, was subjected to a 1000-hr life test evaluation. Hall effect thrusters are propulsion devices that electrostatically accelerate xenon ions to produce thrust. Hall effect propulsion has been in development for many years, and low-power devices (1.35 kW) have been used in space for satellite orbit maintenance. The T-220, shown in the photo, produces sufficient thrust to enable efficient orbital transfers, saving hundreds of kilograms in propellant over conventional chemical propulsion systems. This test is the longest operation ever achieved on a high-power Hall thruster (greater than 4.5 kW) and is a key milestone leading to the use of this technology for future NASA, commercial, and military missions.

  6. WINDFARMperception. Visual and acoustic impact of wind turbine farms on residents. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Frits van den (Faculty of Mathematics and Natural Sciences, Univ. of Groningen, Groningen (Netherlands)); Pedersen, Eja (Dept. of Public Health and Community Medicine, Goeteborg Univ., Goeteborg (Sweden)); Bouma, Jelte; Bakker, Roel (Northern Centre for Health Care Research, Univ. Medical Centre, Groningen (Netherlands))

    2008-06-15

    This report gives the results of the EU financed study WINDFARMperception on how residents perceive a wind farm in their living environment as far as sound and sight are concerned. The study includes a postal survey among Dutch residents (n = 725, response rate: 37%) and an assessment of their aural and visual exposure due to wind farms in their vicinity. The study group was selected from all residents in the Netherlands within 2.5 km from a wind turbine. As the study aimed to study modern wind farms, wind turbines were selected with an electric capacity of 500 kW or more and one or more turbines within 500 m from the first. Excluded were wind turbines that were erected or replaced in the year preceding the survey. Respondents were exposed to levels of wind turbine sound between 24 and 54 dBA and wind turbines at distances from 17 m to 2.1 km. The (angular) height of the biggest wind turbine ranged from 2 degrees to 79 degrees, with an average value of 10 degrees (the height of a CD box, looking at the front at arm's length). The wind turbines occupied on average 2% of the space above the horizon. The percentage of respondents that were annoyed by the sound also increased with sound level up to 40 to 45 dBA and then decreased. Respondents with economic benefits reported almost no annoyance. This in part explains the decrease in annoyance at high sound levels: above 45 dBA, i.e. close to wind turbines, the majority of respondents have economical benefits. There is no indication that the sound from wind turbines had an effect on respondents' health, except for the interruption of sleep. At high levels of wind turbine sound (more than 45 dBA) interruption of sleep was more likely than at low levels. Higher levels of background sound from road traffic also increased the odds for interrupted sleep. Annoyance from wind turbine sound was related to difficulties with falling asleep and to higher stress scores. From this study it cannot be concluded whether these

  7. International wind energy development. World market update 2000. Forecast 2001-2005

    International Nuclear Information System (INIS)

    2001-03-01

    In the year 2000, the wind power development took another major step forward. Installed capacity set a new record with the additon of 4,495 MW of new generating capacity, this is 574 MW more than the record set in 1999. Growth in new capacity declined from 51% in 1999 to 15% in 2000. Nevertheless, the trend of wind energy being preferred over other technologies for new generating capacity is continuing. Europe remains the major market for wind power. Of the new capacity added in 2000, 86% was installed in Europe. Germany again took the lead as the single most active market with the installation of 1,665 MW in new capacity, 100 MW more than in the previous year. In doing so, Germany extended its reign as the world's leading developer of wind energy. Spain also took a major step towards meeting its renewable energy goals with the installation of some 1,024 MW of new wind generating capacity. Denmark replaced the United States as the world's third largest market. The Danes installed a new record of 603 MW. This was due to a last-minute rush of contracts signed at the end of 1999 in order to utilize attractive payment rates for new installations, which expired at the end of the year. The turbines were then installed in 2000. Market leaders among wind turbine manufacturers changed from previous years. Vestas Wind Systems A/S is now the world's largest manufacturer of wind turbines, followed by Gamesa S.A. of Spain (Vestas owns 40% of the shares in the Spanish company). Enercon GmbH has become the third largest manufacturer of wind turbines. It is interesting to note that Enercon GmbH made steady progress in sales to several emerging markets throughout the world. New on the Top-10 list is an Indian manufacturer. Suzlon Energy Ltd. installed 103 MW of capacity and thereby becomes the number 10 in the list of the worlds largest manufacturer. The cumulative installed capacity of 18,449 MW at the end of 2000 will supply approximately 37 TWh (37 billion kWh) per year. The

  8. An experimental and numerical study of the atmospheric stability impact on wind turbine wakes

    DEFF Research Database (Denmark)

    Machefaux, Ewan; Larsen, Gunner Chr.; Koblitz, Tilman

    2016-01-01

    campus test site. Wake measurements are averaged within a mean wind speed bin of 1 m s1 and classified according to atmospheric stability using three different metrics: the Obukhov length, the Bulk–Richardson number and the Froude number. Three test cases are subsequently defined covering various...... atmospheric conditions. Simulations are carried out using large eddy simulation and actuator disk rotor modeling. The turbulence properties of the incoming wind are adapted to the thermal stratification using a newly developed spectral tensor model that includes buoyancy effects. Discrepancies are discussed......In this paper, the impact of atmospheric stability on a wind turbine wake is studied experimentally and numerically. The experimental approach is based on full-scale (nacelle based) pulsed lidar measurements of the wake flow field of a stall-regulated 500 kW turbine at the DTU Wind Energy, Risø...

  9. The Cost of Transmission for Wind Energy: A Review of Transmission Planning Studies

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Andrew D.; Wiser, Ryan; Porter, Kevin

    2009-02-02

    and WinDS). The authors and general location of the 40 detailed transmission studies included in our review are illustrated in Figure ES-1. As discussed in the body of the report, these studies vary considerably in scope, authorship, objectives, methodology, and tools. Though we recognize this diversity and are cognizant that comparisons among these studies are therefore somewhat inappropriate, we nonetheless emphasize such simple comparisons in this report. We do so in order to improve our understanding of the range of transmission costs needed to access greater quantities of wind, and to highlight some of the drivers of those costs. In so doing, we gloss over many important details and differences among the studies in our sample. In emphasizing simple comparisons, our analysis focuses primarily on the unit cost of transmission implied by each of the studies. The unit cost of transmission for wind in $/kW terms on a capacity-weighted basis is estimated by simply dividing the total transmission cost in a study by the total amount of incremental generation capacity (wind and non-wind) modeled in that study. In so doing, this metric assumes that within any individual study all incremental generation capacity imposes transmission costs in proportion to its nameplate capacity rating. The limitations to this approach are described in some detail in the body of the report.

  10. Minimization of emissions. (CO and NO) on a 300 kW wood fuel boiler

    International Nuclear Information System (INIS)

    Johansson, Erik

    1997-01-01

    The purpose with this investigation was to study a 300 kW power plant in Ed, Dalsland that is using biomass as fuel and to reduce CO and NO-pollutants as much as possible. The experiments were performed according to statistical experimental design and the result was compared with similar studies. The most important results of the present work were: Today, the boiler is using biomass with too much moisture and that's the reason why the smoke contains a great quantity of CO. This could be reduced with a lower quantity of moisture in the biomass or rebuilding of the boiler. Doors and dampers should be fully closed so air can't pass through because that would reduce the energy losses in the smoke. The automatic control should be changed to reduce the time that biomass are not transported in to the boiler. Biomass with low content of moisture (about 15 %) are a good fuel in the boiler. The smoke needs to be measured continuously to reduce the pollutants because it is not possible to detect visually. If a low amount of oxygen in the smoke (7 %) and high amount of primary air (52 % of total air) and the plant is using low power (120 kW), pollutants is reduced. When using middle power (190 kW), a low amount of oxygen in the smoke is also needed (7%) but a smaller amount of air to the bed (40%) will reduce pollutants. The reason for this is probably that too much air in the bed will make it too cool. The result showed that by using statistical experimental design the amount of CO was reduced with 45 % to 263 ppm and the amount of NO reduced with 80 % to 30 ppm (51 mg/MJ NO 2 ) while using biomass with 34 % moisture Examination paper. 28 refs, 13 figs, 9 tabs, appendixes

  11. Composite wind turbine towers

    Energy Technology Data Exchange (ETDEWEB)

    Polyzois, D. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Civil Engineering

    2008-07-01

    This paper discussed experiments conducted to optimized the advanced composite materials such as fiberglass reinforced plastics (FRP) used to fabricate wind turbine towers. FRP materials are used in tubular steel, lattice, guyed, and reinforced concrete towers. The towers and turbine blades are transported in segments and assembled on-site, sometimes in offshore or remote locations.The FRP composites are used to build towers with a high strength-to-weight ratio as well as to provide resistance to chemical attacks and corrosion. Use of the materials has resulted in towers that do not require heavy installation equipment. Experimental programs were conducted to verify the structural behaviour of the tower structure's individual-scaled cells as well as to evaluate the performance of multi-cell assemblies. Joint assembly designs were optimized, and a filament winding machine was used to conduct the experimental study and to test individual cells. Failure mode analyses were conducted to determine local buckling and shear rupture. Tension, compression, and shear properties of the FRP materials were tested experimentally, and data from the test were then used to develop finite element models of the composite towers as well as to obtain load deflection curves and tip oscillation data. A case study of a 750 kW wind turbine in Churchill, Manitoba was used to test the design. tabs., figs.

  12. Analytical Aerodynamic Simulation Tools for Vertical Axis Wind Turbines

    International Nuclear Information System (INIS)

    Deglaire, Paul

    2010-01-01

    Wind power is a renewable energy source that is today the fastest growing solution to reduce CO 2 emissions in the electric energy mix. Upwind horizontal axis wind turbine with three blades has been the preferred technical choice for more than two decades. This horizontal axis concept is today widely leading the market. The current PhD thesis will cover an alternative type of wind turbine with straight blades and rotating along the vertical axis. A brief overview of the main differences between the horizontal and vertical axis concept has been made. However the main focus of this thesis is the aerodynamics of the wind turbine blades. Making aerodynamically efficient turbines starts with efficient blades. Making efficient blades requires a good understanding of the physical phenomena and effective simulations tools to model them. The specific aerodynamics for straight bladed vertical axis turbine flow are reviewed together with the standard aerodynamic simulations tools that have been used in the past by blade and rotor designer. A reasonably fast (regarding computer power) and accurate (regarding comparison with experimental results) simulation method was still lacking in the field prior to the current work. This thesis aims at designing such a method. Analytical methods can be used to model complex flow if the geometry is simple. Therefore, a conformal mapping method is derived to transform any set of section into a set of standard circles. Then analytical procedures are generalized to simulate moving multibody sections in the complex vertical flows and forces experienced by the blades. Finally the fast semi analytical aerodynamic algorithm boosted by fast multipole methods to handle high number of vortices is coupled with a simple structural model of the rotor to investigate potential aeroelastic instabilities. Together with these advanced simulation tools, a standard double multiple streamtube model has been developed and used to design several straight bladed

  13. Beam Transport Devices for the 10 kW IR Free Electron Laser

    International Nuclear Information System (INIS)

    Lawrence Dillon-Townes; Michael Bevins; David Kashy; Stephanie Slachtouski; Ronald Lassiter; George Neil; Michelle Shinn; Joseph Gubeli; Christopher Behre; David Douglas; David W. Waldman; George Biallas; Lawrence Munk; Christopher Gould

    2005-01-01

    Beam transport components for the 10kW IR Free Electron Laser (FEL) at Thomas Jefferson National Accelerator Facility (Jefferson Lab) were designed to manage (1) electron beam transport and (2) photon beam transport. An overview of the components will be presented in this paper. The electron beam transport components were designed to address RF heating, maintain an accelerator transport vacuum of 1 x 10 -8 torr, deliver photons to the optical cavity, and provide 50 kW of beam absorption during the energy recovery process. The components presented include a novel shielded bellows, a novel zero length beam clipper, a one decade differential pumping station with a 7.62 cm (3.0 inch) aperture, and a 50 kW beam dump. The photon beam transport components were designed to address the management of photons delivered by the accelerator transport. The optical cavity manages the photons and optical transport delivers the 10 kW of laser power to experimental labs. The optical cavity component presented is a unique high reflector vessel and the optical transport component presented is a turning mirror cassette

  14. Maximizing Energy Capture of Fixed-Pitch Variable-Speed Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, K.; Migliore, P.

    2000-08-01

    Field tests of a variable-speed, stall-regulated wind turbine were conducted at a US Department of Energy Laboratory. A variable-speed generating system, comprising a doubly-fed generator and series-resonant power converter, was installed on a 275-kW, downwind, two-blade wind turbine. Gearbox, generator, and converter efficiency were measured in the laboratory so that rotor aerodynamic efficiency could be determined from field measurement of generator power. The turbine was operated at several discrete rotational speeds to develop power curves for use in formulating variable-speed control strategies. Test results for fixed-speed and variable-speed operation are presented along with discussion and comparison of the variable-speed control methodologies. Where possible, comparisons between fixed-speed and variable-speed operation are shown.

  15. Demonstration of the 500 kW stoker burning system; 500 kW stokeripolttojaerjestelmaen demonstrointi

    Energy Technology Data Exchange (ETDEWEB)

    Oravainen, H. [VTT Energy, Jyvaeskylae (Finland); Kantalainen, K. [Hoegfors Laempoe Oy, Saarijaervi (Finland)

    1995-12-31

    The objective of the project is to demonstrate the operation of a 500 kW stoker-burning system in practice. The project is continuation of the previous projects of the Bioenergy research programme, 303 - Development of automatic heating system for wood chips and sod peat, carried out by VTT Energy, and Y301 - Development of heating boiler for wood chips and sod peat, carried out by Hoegfors Laempoe Oy. A 500 kW (nominal power) stoker-burner was constructed on the basis of the results of these projects. The burner was mounted on ETNA 500 bioenergy boiler. Screw-feeders, constructed by Maamiehen Saehkoe Oy, were used as fuel feeding system. Maamiehen Saehkoe Oy delivered also the automation system for the combustion equipment. Combustion air pre-heater was mounted on the boiler for promotion of the combustion of moist fuel. Testing of the equipment was carried out at the laboratory of VTT Energy in Jyvaeskylae in October-November 1994. In December 1994 the equipment was transported to Jalasjaervi, to heating station of the farmer Juha Jyrae. The actual heat generation started in the beginning of February 1995, when the greenhouses started to require heating. Sod peat has been used as the fuel. VTT Energy has carried out the efficiency and emission measurements in the heating station with sod peat in March 1995, and with reed canary grass in autumn 1995. The energy generation and fuel consumption have been followed all the time

  16. Demonstration of the 500 kW stoker burning system; 500 kW stokeripolttojaerjestelmaen demonstrointi

    Energy Technology Data Exchange (ETDEWEB)

    Oravainen, H [VTT Energy, Jyvaeskylae (Finland); Kantalainen, K [Hoegfors Laempoe Oy, Saarijaervi (Finland)

    1996-12-31

    The objective of the project is to demonstrate the operation of a 500 kW stoker-burning system in practice. The project is continuation of the previous projects of the Bioenergy research programme, 303 - Development of automatic heating system for wood chips and sod peat, carried out by VTT Energy, and Y301 - Development of heating boiler for wood chips and sod peat, carried out by Hoegfors Laempoe Oy. A 500 kW (nominal power) stoker-burner was constructed on the basis of the results of these projects. The burner was mounted on ETNA 500 bioenergy boiler. Screw-feeders, constructed by Maamiehen Saehkoe Oy, were used as fuel feeding system. Maamiehen Saehkoe Oy delivered also the automation system for the combustion equipment. Combustion air pre-heater was mounted on the boiler for promotion of the combustion of moist fuel. Testing of the equipment was carried out at the laboratory of VTT Energy in Jyvaeskylae in October-November 1994. In December 1994 the equipment was transported to Jalasjaervi, to heating station of the farmer Juha Jyrae. The actual heat generation started in the beginning of February 1995, when the greenhouses started to require heating. Sod peat has been used as the fuel. VTT Energy has carried out the efficiency and emission measurements in the heating station with sod peat in March 1995, and with reed canary grass in autumn 1995. The energy generation and fuel consumption have been followed all the time

  17. Wind energy as a potential generation source at Ras Benas, Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed Shata [Physics Department, Faculty of Science in Port Said, Suez Canal University (Egypt)

    2010-10-15

    Analysis of the wind characteristics in Ras Benas city located on the east coast of Red Sea in Egypt using measured data (wind, pressure and temperature) and Weibull function were made. Statistical analysis model to evaluate the wind energy potential was introduced. According to the power calculations done for the site, the annual mean wind density is 315 kW/m{sup 2} at a height of 70 m above ground level. This station has a huge wind energy potential for electricity generation, especially during spring and summer seasons, comparing with some European countries. In addition, the monthly wind turbine efficiency parameter ({eta}{sub monthly}) has been calculated by using a commercial wind turbine 1 MW with 70 m hub height to help designers and users in evaluating the potentialities and choosing the suitable wind turbine for the considered site. The use of wind turbine with capacity greater than 1000 kW at this station was recommended. Ras Benas station was selected to install 30 MW-wind farm consists of 20 commercial wind turbines (Nordex S 77) with hub heights and Rotor diameter were 100 and 77 m, respectively. This site has annual wind speed more than 9.8 m/s at 100 m height and enough area to locate these turbines. The estimated energy production using WASP Program of these wind farm was 130 GWh/year. Furthermore, the production costs was found 1.3EUR cent/kWh, which is a competition price at the wind energy world market. (author)

  18. Wind energy as a potential generation source at Ras Benas, Egypt

    International Nuclear Information System (INIS)

    Ahmed, Ahmed Shata

    2010-01-01

    Analysis of the wind characteristics in Ras Benas city located on the east coast of Red Sea in Egypt using measured data (wind, pressure and temperature) and Weibull function were made. Statistical analysis model to evaluate the wind energy potential was introduced. According to the power calculations done for the site, the annual mean wind density is 315 kW/m 2 at a height of 70 m above ground level. This station has a huge wind energy potential for electricity generation, especially during spring and summer seasons, comparing with some European countries. In addition, the monthly wind turbine efficiency parameter (η monthly ) has been calculated by using a commercial wind turbine 1 MW with 70 m hub height to help designers and users in evaluating the potentialities and choosing the suitable wind turbine for the considered site. The use of wind turbine with capacity greater than 1000 kW at this station was recommended. Ras Benas station was selected to install 30 MW-wind farm consists of 20 commercial wind turbines (Nordex S 77) with hub heights and Rotor diameter were 100 and 77 m, respectively. This site has annual wind speed more than 9.8 m/s at 100 m height and enough area to locate these turbines. The estimated energy production using WASP Program of these wind farm was 130 GWh/year. Furthermore, the production costs was found 1.3EUR cent/kWh, which is a competition price at the wind energy world market. (author)

  19. Spent fuel consolidation in the 105KW Building fuel storage basin

    International Nuclear Information System (INIS)

    Johnson, B.H.

    1994-01-01

    This study is one element of a larger engineering study effort by WHC to examine the feasibility of irradiated fuel and sludge consolidation in the KW Basin in response to TPA Milestone (target date) M-34-00-T03. The study concludes that up to 11,500 fuel storage canisters could be accommodated in the KW Basin with modifications. These modifications would include provisions for multi-tiered canister storage involving the fabrication and installation of new storage racks and installation of additional decay heat removal systems for control of basin water temperature. The ability of existing systems to control radionuclide concentrations in the basin water is examined. The study discusses requirements for spent nuclear fuel inventory given the proposed multi-tiered storage arrangement, the impact of the consolidated mass on the KW Basin structure, and criticality issues associated with multi-tiered storage

  20. Testing of a direct drive generator for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Sondergaard, L.M. [Riso National Laboratory, Roskilde (Denmark)

    1996-12-31

    The normal drive train of a wind turbine consists a gearbox and a 4 to 8 poles asynchronous generator. The gearbox is an expensive and unreliable components and this paper deals with testing of a direct drive synchronous generator for a gearless wind turbine. The Danish company Belt Electric has constructed and manufactured a 27 kW prototype radial flux PM-generator (DD600). They have used cheap hard ferrite magnets in the rotor of this PM-generator. This generator has been tested at Riso and the test results are investigated and analyzed in this paper. The tests have been done with three different load types (1: resistance; 2: diode rectifier, DC-capacitor, resistance; 3: AC-capacitor, diode rectifier, DC-capacitor, resistance). 1 ref., 9 figs., 5 tabs.

  1. Design and fabrication of a composite wind turbine blade

    Science.gov (United States)

    Brown, R. A.; Haley, R. G.

    1980-01-01

    The design considerations are described which led to the combination of materials used for the MOD-I wind turbine generator rotor and to the fabrication processes which were required to accomplish it. It is noted that the design problem was to create a rotor for a 2500 kW wind turbine generator. The rotor was to consist of two blades, each with a length of 97.5 feet and a weight of less than 21,000 pounds. The spanwise frequency is 1.17-1.45 Hz, and the chordwise frequency 2.80-2.98 Hz. The design life of the blade is 30 years, or 4.35 x 10 to the 8th cycles. The structures of the spars and trailing edges are described, and the adhesive bonding system is discussed.

  2. Computation of Superconducting Generators for Wind Turbine Applications

    DEFF Research Database (Denmark)

    Rodriguez Zermeno, Victor Manuel

    The idea of introducing a superconducting generator for offshore wind turbine applications has received increasing support. It has been proposed as a way to meet energy market requirements and policies demanding clean energy sources in the near future. However, design considerations have to take......, to the actual generators in the KW (MW) class with an expected cross section in the order of decimeters (meters). This thesis work presents cumulative results intended to create a bottom-up model of a synchronous generator with superconducting rotor windings. In a first approach, multiscale meshes with large...... of the generator including ramp-up of rotor coils, load connection and change was simulated. Hence, transient hysteresis losses in the superconducting coils were computed. This allowed addressing several important design and performance issues such as critical current of the superconducting coils, electric load...

  3. Report on the field test project for wind power development at Kamiyaku Town (wind characteristics investigation); Kamiyakucho ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Wind characteristics are observed for a year at the above town located at the northern end of the Yakushima island, Kagoshima Prefecture. The exponential index of the wind speed distribution in the vertical direction is 6.06 with all the directions averaged, and is so high as 8.4/13.6 in the wind directions (W/E). Prudence should be exercised, when to estimate the wind speed at the wind turbine hub altitude, against disjunction from the simple exponential law due to geographical peculiarities of the observation location. Turbulence intensity is low and is 0.15 when the wind speed is 2m/s or more, not exerting an ill effect on wind power development. As for the total wind direction occurrence rate on the prevalent wind axis, 78.2% is recorded, which is much higher than the reference value (60%). The average wind speed on this wind axis is high, and this shows that the location is quite suitable for wind power development. The annual average wind speed of 6.3m/s is much higher than the reference value, this again promising a success. The wind energy density of 478W/m{sup 2} is sufficiently high, as compared with the reference value (215W/m{sup 2}). Since there are possibilities of a maximum instantaneous wind speed of over 60m/s, caution is to be used in determining wind endurance for the wind turbine design. The annual capacity ratios for the 150/300/750kW wind turbine models are 33.8/36.5/36.9%, respectively, higher than the NEDO-provided reference value (17% or higher) and predicting sufficient power generation. (NEDO)

  4. A compact, high efficiency contra-rotating generator suitable for wind turbines in the urban environment

    Energy Technology Data Exchange (ETDEWEB)

    Booker, J.D. [Department of Mechanical Engineering, University of Bristol, University Walk, Bristol BS8 1TR (United Kingdom); Mellor, P.H.; Wrobel, R.; Drury, D. [Department of Electrical and Electronic Engineering, University of Bristol, Bristol (United Kingdom)

    2010-09-15

    This paper is concerned with the design, development and performance testing of a permanent magnet (PM) generator for wind turbine applications in urban areas. The radially interacting armature windings and magnet array are carried on direct drive, contra-rotating rotors, resulting in a high torque density and efficiency. This topology also provides improved physical and mechanical characteristics such as compactness, low starting torque, elimination of gearboxes, low maintenance, low noise and vibration, and the potential for modular construction. The design brief required a 50 kW continuous rated prototype generator, with a relative speed at the air-gap of 500 rpm. A test rig has been instrumented to give measurements of the mechanical input (torque and speed) and electrical output (voltage, current and power) of the generator, as well as temperature readings from inside the generator using a wireless telemetry device. Peak power output was found to be 48 kW at a contra-rotating speed of 500 rpm, close to the design target, with an efficiency of 94%. It is anticipated that the generator will find application in a wide range of wind turbine designs suited to the urban environment, e.g. types sited on the top of buildings, as there is growing interest in providing quiet, low cost, clean electricity at point of use. (author)

  5. Study on wind turbine for Yamagata wind energy institute. Comparison of the actual and estimate values for electric power; Yamagata furyoku hatsudensho no fusha ni tsuite. Hatsudenryo yosoku to jissekichi no hikaku

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, H [Nihon University, Tokyo (Japan); Kojima, T [Yamagata Wind Energy Institute, Yamagata (Japan)

    1996-10-27

    For two 400kW wind turbines erected in Jan. 1996 of Yamagata Wind Energy Institute, their estimated power output was compared with actual output for 7 months. AMeDAS data in 1985-94 were totaled every month to use as basic data. The altitude and surface roughness model necessary for WAsP analysis recommended by NEDO`s wind condition close inspection manual were prepared using 1/25,000 maps and aerial photographs. The obstacle model for estimating wind conditions at height of the wind turbine was prepared using the data obtained by field survey. Mean wind velocity and latent energy were determined by statistical analysis of wind velocity occurrence relative frequencies and Weibull distribution parameters. The power output of 717,700kWh was obtained for 7 months, which is equivalent to 88.5% of the estimated output of 810,730kWh for the same period. It was clarified from obtained characteristic wind conditions at the site that the wind power generation is promising at the site not only in winter but also in summer. Although the test period was too short, this method was effective as analytical method of output estimation in the planning stage of wind turbines. 3 refs., 8 figs., 4 tabs.

  6. Starting-up sequence of the AWEC-6 0 wind turbine; Secuencia de Arranaue del Aerogenerador AWEC-60

    Energy Technology Data Exchange (ETDEWEB)

    Avia, F.; Cruz, M. de la

    1991-07-01

    One of the most critical status of the wind turbines operation is the starting-up sequence and the connection to the grid, due to the actuating loads that could be several times the loads during operation at rated conditions. Due to this fact, the control strategy is very important during the starting-up sequence in order to minimize the loads on the machine. For this purpose it is necessary to analyze the behaviour of the wind turbine during that sequence in different wind conditions and machine conditions This report shows the graphic Information about fifty starting-up sequences of the AWEC-60 wind turbine of 60 m diameter and 1200 kW of rated power, recorded in April 1991 and covering all the operation range between cut-in and cut-out wind speed. (Author) 2 refs.

  7. The possible hindrance of a 10 MW wind farm along the Noordermeerdijk in the Noordoostpolder, Netherlands, for birds. De mogelijke hinder van een 10 MW windpark langs de Noordermeerdijk (NOP) voor vogels

    Energy Technology Data Exchange (ETDEWEB)

    Van den Bergh, L M.J.; Spaans, A L

    1993-01-01

    The title farm comprises 14 two-bladed 750 kW wind turbines. Hindrance of wind turbines are collisions with the wind turbines and in the wake behind the blades and loss or disintegration of the natural habitat because of the presence of the wind turbines (aspect of disturbance). The title study is focused on counting the number of collision bird victims per year, and analyzing the disturbance effects on hibernating and foraging birds. It appeared that almost 150 to more than 1500 birds will collide with one of the 16 wind turbines. A few hundred tufted ducks, some tens of pochard and some tens of wild ducks per kilometer of the array will leave their natural habitat. Based on the results it is concluded that the site south of the kilometre marker 7.0 is preferred to the site directly south of kilometre marker 5.0. It is also concluded that the above-mentioned array is preferred to a wind turbine array of 16 wind turbines of 500 kW each. The results of the investigation on that array are published in a separate report for which a separate abstract has been prepared. 2 figs., 6 tabs., 2 appendices, 34 refs.

  8. Fiscal 1998 survey report. Assessment and analysis of collected data in wind power generation field test project; 1998 nendo furyoku hatsuden field test jigyo ni okeru shushu data hyoka kaiseki chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Examination was made on wind conditions, power generating characteristics, and the reliability of a system by analyzing the operation record of the wind power generation equipment which was installed at Hiraizumi-cho, Nishi-Iwai gun, Iwate prefecture and at Misaki-cho, Miura-shi, Kanagawa prefecture. The equipment at Hiraizumi had a rated output of 490 kW, and at Miura 400 kW. The period of the examination was from April, 1998 through February, 1999, the items for data collection being the generator output, generated energy, average wind velocity, record of abnormality occurrence, and maximum wind velocity. At Hiraizumi, annual average utilization rate was 12.9%; annual average operation rate, 49.9%; average wind velocity, 4.6 m/s; and maximum wind velocity of the period, 31 m/s. At Miura, annual average utilization rate was 16.5%; annual average operation rate, 77.0%; and average wind velocity, 5.0 m/s. The utilization rate is desirably 17%. The top three abnormalities were drop in AC control voltage, actuation of main shaft brake and eddy current/actuation of open phase relay, accounting for 83.3% of the total abnormalities at Hiraizumi, while they were unbalance in current, grid drop and automatic unwinding of cable, accounting for 74.5% at Miura. (NEDO)

  9. Research report of fiscal 1997. Feasibility research on domestic wind farms; 1997 nendo chosa hokokusho. Kokunai wind farm kanosei chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Research was made on large-scale wind power generation projects under planning or construction. Issues of the following 5 areas were arranged considering topographic, geographic and meteorological conditions, and the type of municipal corporations: Tomamae town, Hokkaido, Tachikawa town, Yamagata prefecture (third-sector), Hisai city, Mie prefecture, Otoyo town, Kochi prefecture, and Kishuku town, Nagasaki prefecture (third-sector). These projects are supported by MITI`s local new energy introduction promotion project subsidy started in fiscal 1997 covering a half of construction cost (within 200 million yen/year). Requirements for this subsidy are that an applicant is either a municipal corporation or a third-sector, and that a total generating capacity is not less than 1200kW. Another subsidy system covering 1/3 of construction cost and a debt guarantee system are prepared for large-scale private projects not less than 800kW. Hearing was made on some private projects in Esashi town, Akita city and Hasaki town. Technical requirements, specifications, guideline and some examples for system interconnection are also summarized. 10 figs., 24 tabs.

  10. Development of a 200kW multi-fuel type PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Take, Tetsuo; Kuwata, Yutaka; Adachi, Masahito; Ogata, Tsutomu [NTT Integrated Information & Energy System Labs., Tokyo (Japan)

    1996-12-31

    Nippon Telegraph and Telephone Corporation (NFT) has been developing a 200 kW multi-fuel type PAFC power plant which can generate AC 200 kW of constant power by switching fuel from pipeline town gas to liquefied propane gas (LPG) and vice versa. This paper describes the outline of the demonstration test plant and test results of its fundamental characteristics.

  11. Wind power goes offshore. European workshop, exhibition and technical tour within the frame of the EU funded project 'German-Polish cross border OPET'

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Along with hydroelectric, wind power is today's major and expanding producer of electricity from renewable sources. So far mainly coastal locations have been used around Europe, and potential for expansion lies especially in places which until now have been used little or not at all. The European Commission White Paper states: ''In particular, there is enormous potential for offshore wind farms [..] In order to achieve large-scale penetration of wind energy in the European Union these areas have also to be used.'' However, other location factors and technical challenges on the open sea demand very careful and thorough planning. As early as 1991, 11 450-kW wind turbine generators came into operation in the Vindeby offshore wind park in Denmark. The Tun diameter Knob park followed in 1995 with 10 500-kW units. By contrast, no wind park is expected to be operating off the coast of Germany until 2005. All around the North Sea and the Baltic Ring, plans are being laid to erect offshore wind power facilities - but in many places the legal and technical framework conditions are the subject of scrutiny on criteria of nature conservation and suitability for the location. The 'Wind Power goes Offshore' seminar presents current planning in Denmark, Sweden, Poland and Germany. There will be reports on experiences with running existing plants, and on procedures for setting up new projects. The seminar and concurrent exhibition were intended to stimulate wide exchanges of information and networking between practitioners at European level. The seminar was for manufacturers, planners and operators of wind power plants, environmental and nature conservation organisations, local authorities, and energy supply companies around the North Sea and the Baltic Ring. (orig.) [German] Windenergie leistet heute neben der Wasserkraft den groessten Beitrag zur Stromerzeugung aus erneuerbaren Energietraegern - Tendenz steigend. Nachdem bisher europaweit

  12. Comparison of acoustic data from a 102 mm conic nozzle as measured in the RAE 24-foot wind tunnel and the NASA Ames 40- by 80-foot wind tunnel

    Science.gov (United States)

    Atencio, A., Jr.; Mckie, J.

    1982-01-01

    A cooperative program between the Royal Aircraft Establishment (RAE), England, and the NASA Ames Research Center was initiated to compare acoustic measurements made in the RAE 24-foot wind tunnel and in the Ames 40- by 80-foot wind tunnel. The acoustic measurements were made in both facilities using the same 102 mm conical nozzle supplied by the RAE. The nozzle was tested by each organization using its respective jet test rig. The mounting hardware and nozzle exit conditions were matched as closely as possible. The data from each wind tunnel were independently analyzed by the respective organization. The results from these tests show good agreement. In both facilities, interference with acoustic measurement is evident at angles in the forward quadrant.

  13. Gas liquid sampling for closed canisters in KW Basin - test plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    Test procedures for the gas/liquid sampler. Characterization of the Spent Nuclear Fuel, SNF, sealed in canisters at KW-Basin is needed to determine the state of storing SNF wet. Samples of the liquid and the gas in the closed canisters will be taken to gain characterization information. Sampling equipment has been designed to retrieve gas and liquid from the closed canisters in KW basin. This plan is written to outline the test requirements for this developmental sampling equipment

  14. NSWEP: The Nova Scotia Wind Energy Project

    International Nuclear Information System (INIS)

    Hughes, L.; Little, T. A.

    2000-01-01

    A two-phase project, intended to educate Nova Scotians about the potential of wind power to help reduce the province's greenhouse gas emissions, thereby fulfilling a vital role in Canada's effort to mitigate climate change effects, is described. First phase of the project involves gathering of wind data; the second the installation of a number of wind turbines throughout the province. The data gathering phase encompasses site selection, the actual data gathering for a period of about ten months, data analysis, and creation of a four or five module educational program, to be linked with intermediate high school science, mathematics, geography and social studies curriculum objectives to provide an interdisciplinary examination of these topics, and convey a sense of the complexity of the issues involved. The second phase of the project is intended to promote the possible use of wind energy in the province by installing a number of 25 kW wind turbines at selected sites throughout the province, followed by the gathering analysis of data relating to the amount of power produced by the turbines, calculating the efficiency of turbines and comparing data with the data gathered in previous years. The project is expected to last at least five years, exposing about 4000 high school students to hands-on involvement with issues of climate change and sustainable energy. Parents and the community will be exposed to these same issues indirectly, aided by the relative proximity of the weather stations to schools and the strategic location of the wind turbines. 4 refs

  15. Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator

    DEFF Research Database (Denmark)

    Abrahamsen, Asger Bech; Magnusson, Niklas; Liu, Dong

    2014-01-01

    A design study of a 10 MW direct drive wind turbine generator based on MgB2 superconducting wires is presented and the cost of the active materials of the generator is estimated to be between 226 €/kW and 84 €/kw, which is lower than the threshold values of 300 €/kW of the INNWIND.EU project. A n...

  16. The possible hindrance of a 8 MW wind farm along the Zuidermeerdijk in the Noordoostpolder, Netherlands, for birds

    International Nuclear Information System (INIS)

    Van den Bergh, L.M.J.; Spaans, A.L.

    1993-01-01

    The title farm comprises 16 three-bladed 500 kW wind turbines. Hindrance of wind turbines are collisions with the wind turbines and in the wake behind the blades and loss or disintegration of the natural habitat because of the presence of the wind turbines (aspect of disturbance). The title study is focused on counting the number of collision bird victims per year, and analyzing the disturbance effects on hibernating and foraging birds. It appeared that almost 150 to more than 1500 birds will collide with one of the 16 wind turbines. A few hundred tufted ducks, some tens of pochard and some tens of wild ducks per kilometre of the wind farm will leave their natural habitat. Based on the results it is concluded that the dike area between kilometre marker 32.5 and kilometre marker 35.5 is the most suitable area for a wind turbine array along the Zuidermeerdijk in between Schokkerhaven and Ketelbrug, both Netherlands. 3 figs., 5 tabs., 2 appendices, 33 refs

  17. The reconstruction of easterly wind directions for the Eifel region (Central Europe during the period 40.3–12.9 ka BP

    Directory of Open Access Journals (Sweden)

    K. Seelos

    2010-03-01

    Full Text Available A high resolution continuous reconstruction of last glacial wind directions is based on provenance analysis of eolian sediments in a sediment core from the Dehner dry Maar in the Eifel region (Germany. This Maar is suitable to archive easterly wind directions due to its location west of the Devonian carbonate basins of the Eifel-North-South-Zone. Thus, eolian sediments with high clastic carbonate content can be interpreted as an east wind signal. The detection of such east wind sediments is applied by a new module of the RADIUS grain size analyze technique. The investigated time period from 40.3–12.9 ka BP can be subclassified in three units: The first unit covers the periods of the ending GIS-9, H4, and GIS-8. With the exception of H4 (40–38 ka BP the content of organics in our record is relatively high. With the end of GIS-8 (38–36.5 ka the content of organics decrease and the content of dust increases rapidly. The second time slice (36–24 ka BP has an increased content of dust accumulation and a high amount of east winds layers (up to 19% of the dust storms per century came from the east. In comparison, the subsequent period (24–12.9 ka BP is characterized by lower east wind sediments again. Increased frequencies of east wind occur during the time intervals corresponding with the Heinrich events H1 and H2. The unusual H3 show no higher east wind frequency but so do its former and subsequent Greenland stadials. The late LGM (21–18 ka BP is characterized by a slightly elevated east wind frequency again.

  18. Wind power barometer

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    Despite the economic crisis affecting most of the globe's major economies, wind energy continues to gain supporters around the world. Global wind power capacity increased by 40.5 GW between 2010 and 2011 compared to a 39 GW rise between 2009 and 2010, after deduction of decommissioned capacity. By the end of 2011 global installed wind turbine capacity should stand at around 238.5 GW, and much of the world's growth is being driven by capacity build-up in the emerging markets (China, India...). In 2011 Asia was the world's biggest market (52%) ahead of Europe (24.5%) and North-America (19.7%). Europe has still the largest wind power capacity in the world with 40.6% of total in 2011. 2011 was another tough year for Vestas company while Gamesa company has managed to maintain positive profit growth by gaining market shares abroad. Siemens keeps its lead in the offshore market. The Chinese market is now suffering form excess capacity and Chinese companies fell prey to domestic competition

  19. Report on the field test project for wind power development at Yaku Town (wind characteristics investigation); Yakumachi ni okeru furyoku kaihatsu field test jigyo (fukyo seisa) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Wind characteristics are observed for a year at Yakushima Young Travellers' Village of the above-named town, Kagoshima Prefecture. The exponential index of the wind speed distribution in the vertical direction is between 1.6 and 4.7, or 3.5 on the average, relatively small due probably to the peculiar terrain and causing no trouble in the development. Turbulence intensity is 0.16 at when the wind speed is 2m/s or more, low enough to meet the reference value (0.30 or less). The total occurrence rate on the prevalent wind axis (SSE-NNW) is 48%, falling short of the reference value (60% or more). The average wind speed in the prevalent wind direction is high and the wind energy density concentrates on the prevalent wind axis, this showing that the site is good for wind power development. The annual average wind speed is 5.6m/s, slightly lower than the reference value (5.8m/s or more). Since there are possibilities of a maximum instantaneous wind speed of over 60m/s, caution is to be used in determining the wind endurance level for the wind turbine design. The annual wind energy density is 325W/m{sup 2}, fully meeting the reference value (215W/m{sup 2} or more). The annual operation rates of the 150/300/750kW wind turbine models are 61/65/80%, and these meet the reference value (45% or more). Their annual capacity ratios are 24.5/26.6/27.7%, and these again meet the reference value (17% or more). (NEDO)

  20. A study of wind hydrogen production of systems for Malaysia

    International Nuclear Information System (INIS)

    Ibrahim, M.Z.; Kamaruzzaman Sopian; Wan Ramli Wan Daud; Othman, M.Y.; Baharuddin Yatim; Veziroglu, T.N.

    2006-01-01

    Recently, Malaysia is looking into the potential of using hydrogen as future fuel. By recognizing the potential of hydrogen fuel, the government had channeled a big amount of money in funds to related organizations to embark on hydrogen research and development programmed. The availability of indigenous renewable resources, high trade opportunities, excellent research capabilities and current progress in hydrogen research at the university are some major advantages for the country to attract government and industry investment in hydrogen. It is envisaged that overall energy demand in Malaysia as stated in the Eighth Malaysia Plan (EMP) report will increase by about 7.8 percent per annum in this decade at the present economic growth. Considering the vast potential inherent in renewable energy (RE), it could be a significant contributor to the national energy supply. Malaysia had been blessed with abundant and varied resources of energy, nevertheless, concerted efforts should be undertaken to ensure that the development of energy resources would continue to contribute to the nation's economic expansion. In this regard, an initial study has been carried out to see the available potential of wind energy towards the hydrogen production, that could be utilized in various applications particularly in Malaysian climate condition via a computer simulation (HYDROGEMS), which built for TRNSYS (a transient system simulation program) version 15. The system simulated in this study consist of one unit (1 kW) wind turbine, an electrolyze (1 kW), a hydrogen (H 2 ) storage tank, and a power conditioning system. A month hourly data of highest wind speed is obtained from the local weather station that is at Kuala Terengganu Air Port located at 5''o 23'' latitude (N) and 103''o 06'' Longitude (E). The results show, wind energy in Malaysian Climate has a potential to generate hydrogen with the minimum rate approximately 9 m 3 /hr and storage capacity of 60 Nm 3 , State of Charge (SOC

  1. Johnson Space Center's Solar and Wind-Based Renewable Energy System

    Science.gov (United States)

    Vasquez, A.; Ewert, M.; Rowlands, J.; Post, K.

    2009-01-01

    The NASA Johnson Space Center (JSC) in Houston, Texas has a Sustainability Partnership team that seeks ways for earth-based sustainability practices to also benefit space exploration research. A renewable energy gathering system was installed in 2007 at the JSC Child Care Center (CCC) which also offers a potential test bed for space exploration power generation and remote monitoring and control concepts. The system comprises: 1) several different types of photovoltaic panels (29 kW), 2) two wind-turbines (3.6 kW total), and 3) one roof-mounted solar thermal water heater and tank. A tie to the JSC local electrical grid was provided to accommodate excess power. The total first year electrical energy production was 53 megawatt-hours. A web-based real-time metering system collects and reports system performance and weather data. Improvements in areas of the CCC that were detected during subsequent energy analyses and some concepts for future efforts are also presented.

  2. Small wind turbine performance evaluation using field test data and a coupled aero-electro-mechanical model

    Science.gov (United States)

    Wallace, Brian D.

    A series of field tests and theoretical analyses were performed on various wind turbine rotor designs at two Penn State residential-scale wind-electric facilities. This work involved the prediction and experimental measurement of the electrical and aerodynamic performance of three wind turbines; a 3 kW rated Whisper 175, 2.4 kW rated Skystream 3.7, and the Penn State designed Carolus wind turbine. Both the Skystream and Whisper 175 wind turbines are OEM blades which were originally installed at the facilities. The Carolus rotor is a carbon-fiber composite 2-bladed machine, designed and assembled at Penn State, with the intent of replacing the Whisper 175 rotor at the off-grid system. Rotor aerodynamic performance is modeled using WT_Perf, a National Renewable Energy Laboratory developed Blade Element Momentum theory based performance prediction code. Steady-state power curves are predicted by coupling experimentally determined electrical characteristics with the aerodynamic performance of the rotor simulated with WT_Perf. A dynamometer test stand is used to establish the electromechanical efficiencies of the wind-electric system generator. Through the coupling of WT_Perf and dynamometer test results, an aero-electro-mechanical analysis procedure is developed and provides accurate predictions of wind system performance. The analysis of three different wind turbines gives a comprehensive assessment of the capability of the field test facilities and the accuracy of aero-electro-mechanical analysis procedures. Results from this study show that the Carolus and Whisper 175 rotors are running at higher tip-speed ratios than are optimum for power production. The aero-electro-mechanical analysis predicted the high operating tip-speed ratios of the rotors and was accurate at predicting output power for the systems. It is shown that the wind turbines operate at high tip-speeds because of a miss-match between the aerodynamic drive torque and the operating torque of the wind

  3. OSR encapsulation basis -- 100-KW

    International Nuclear Information System (INIS)

    Meichle, R.H.

    1995-01-01

    The purpose of this report is to provide the basis for a change in the Operations Safety Requirement (OSR) encapsulated fuel storage requirements in the 105 KW fuel storage basin which will permit the handling and storing of encapsulated fuel in canisters which no longer have a water-free space in the top of the canister. The scope of this report is limited to providing the change from the perspective of the safety envelope (bases) of the Safety Analysis Report (SAR) and Operations Safety Requirements (OSR). It does not change the encapsulation process itself

  4. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  5. Techno-economic feasibility of hybrid diesel/PV/wind/battery electricity generation systems for non-residential large electricity consumers under southern Iran climate conditions

    International Nuclear Information System (INIS)

    Baneshi, Mehdi; Hadianfard, Farhad

    2016-01-01

    Highlights: • A hybrid electricity generation system for a large electricity consumer was studied. • The PV and wind electricity potentials under given climate conditions were evaluated. • Technical, economical, and environmental issues of different systems were discussed. • The optimum configuration of components was obtained. • The impacts of governmental incentives on economic viability of systems were examined. - Abstract: This paper aims to study the techno-economical parameters of a hybrid diesel/PV/wind/battery power generation system for a non-residential large electricity consumer in the south of Iran. As a case study, the feasibility of running a hybrid system to meet a non-residential community’s load demand of 9911 kWh daily average and 725 kW peak load demand was investigated. HOMER Pro software was used to model the operation of the system and to identify the appropriate configuration of it based on comparative technical, economical, and environmental analysis. Both stand alone and grid connected systems were modeled. The impacts of annual load growth and governmental energy policies such as providing low interest loan to renewable energy projects, carbon tax, and modifying the grid electricity price on viability of the system were discussed. Results show that for off-grid systems the cost of electricity (COE) and the renewable fraction of 9.3–12.6 ₵/kWh and 0–43.9%, respectively, are achieved with photovoltaic (PV) panel, wind turbine, and battery sizes of 0–1000 kW, 0–600 kW, and 1300 kWh, respectively. For on grid systems without battery storage the range of COE and renewable fraction are 5.7–8.4 ₵/kWh and 0–53%, respectively, for the same sizes of PV panel and wind turbine.

  6. Design study of wind turbines 50 kW to 3000 kW for electric utility applications. Volume 3: Supplementary design and analysis tasks

    Science.gov (United States)

    1976-01-01

    Additional design and analysis data are provided to supplement the results of the two parallel design study efforts. The key results of the three supplemental tasks investigated are: (1) The velocity duration profile has a significant effect in determining the optimum wind turbine design parameters and the energy generation cost. (2) Modest increases in capacity factor can be achieved with small increases in energy generation costs and capital costs. (3) Reinforced concrete towers that are esthetically attractive can be designed and built at a cost comparable to those for steel truss towers. The approach used, method of analysis, assumptions made, design requirements, and the results for each task are discussed in detail.

  7. Wind farm balance of plant costs

    International Nuclear Information System (INIS)

    Craig, L.; Liebmann, C.

    1992-01-01

    The study consisted of a detailed investigation of the infrastructure required for the construction and operation of a windfarm in the UK. Costing of the equipment and installation was carried out for three UK sites, with different physical characteristics. A literature survey was carried out to determine current practice in the siting of turbines within windfarms in Europe and the USA. Wind turbines were then laid out on the sites selected for study. Requirements and costs for roads, foundations and site buildings, site electrical system and grid connection, the supervisory control and data acquisition system were discussed and evaluated. A comparison between the balance of plant costs for the 33-metre MS-3 400 kW wind turbine and the 50-metre LS-2 1 MW wind turbine was made for each area of study. Overall balance of plant costs was reviewed, with an investigation of the cost components which are most sensitive to variations. The balance of plant costs averaged over the three sites were 13.0 p/kWh/annum for the MS3 windfarms and 10.6 p/kWh/annum for the LS-2 windfarms. Maps of the sites under investigation, design drawings and tables of costs are included to give supporting information to the text. (author)

  8. 1.8kW laser diode pumped YAG laser; Shutsuryoku 1.8kW no handotai laser reiki YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Toshiba Corporation, as a participant in Ministry of International Trade and Industry`s `photon measurement and processing technology project` since August, 1997, is engaged in the development of an energy-efficient LD (laser diode) pumped semiconductor YAG (yttrium-aluminum-garnet) laser device to be used for welding and cutting. It is a 5-year project and the goal is a mean output of 10kW and efficiency of 20%. In this article, a simulation program is developed which carries out calculation about element technology items such as the tracking of the beam from the pumping LD and the excitation distribution, temperature distribution, thermal stress distribution, etc., in the YAG rod. An oscillator is constructed, based on the results of the simulation, and it exhibits a world-high class continuous laser performance of a 1.8kW output and 13% efficiency. The record of 13% efficiency is five times higher than that achieved by the conventional lamp-driven YAG laser device. (translated by NEDO)

  9. A 2.5-kW industrial CO2 laser

    Science.gov (United States)

    Golov, V. K.; Ivanchenko, A. I.; Krasheninnikov, V. V.; Ponomarenko, A. G.; Shepelenko, A. A.

    1986-06-01

    A fast-flow laser is reported in which the active medium is excited by a self-sustained dc discharge produced by an electric-discharge device with nonsectioned electrodes. In the laser, two discharge gaps are formed by a flat anode and two cathodes, one on each side of the anode. A gas mixture is driven through the gasdynamic channel by a centrifugal fan rotating at 6000 rpm/min. With a mixture of CO2:N2:He = 2.5:7.5:5 mm Hg, the rated power is 2.5 kW; the maximum power is 4 kW with the mixture 2.5:7.5:10 mm Hg. The general design of the laser is described, and its principal performance characteristics are given.

  10. Offshore wind investments – Realism about cost developments is necessary

    International Nuclear Information System (INIS)

    Schwanitz, Valeria Jana; Wierling, August

    2016-01-01

    Data available from the recent boom in European offshore wind investments contradict widely held expectations about a decline in costs per kW. Our review shows that scenario projections for investment costs are systematically flawed by over-optimistic assumptions. Contrasting offshore wind technology with onshore wind and nuclear power, we argue that offshore wind could be a candidate for negative learning since a trend towards more complex OWP (offshore wind parks) exists and uncertainty remains high. We estimate technical uncertainty and input cost uncertainty to calculate whether investments in offshore wind technology are profitable today. Applying a real option model to two reference plants using empirically derived parameter values, we allow for sunk cost and the possibility to abandon the investment. We find that for a large parameter range, investments are not profitable, even with substantial support such as feed-in tariffs under the German Energy Act. Therefore, policy incentives for building larger and more complex offshore wind parks bear a high risk to fail in their aim of bringing down investment costs. Policies that instead incentivize the optimization of offshore wind technology – in particular by increasing the load factor and material efficiency and bringing down decommissioning costs – are more sustainable. - Highlights: • We review offshore wind power investments. • Contrary to expectations costs increase. • It is unlikely to see a turn in the near future as complexity is growing. • We deploy an empirically based real option model. • Investments are not profitable across a large parameter range.

  11. 105KE and 105KW Basins fuel and sludge consolidation study, summary report

    International Nuclear Information System (INIS)

    Gant, R.G.

    1994-01-01

    This study is a summary report that examines and evaluates the feasibility of consolidating irradiated fuel and sludge currently in KE Basin with that in the KW Basin. This study was conducted in support of TPA Milestone (target date) M-34-00-T03. The report summarizes three supporting engineering studies involving: (1) spent fuel consolidation into the single basin, (2) transport of the encapsulated fuel between KE and KW Basins, and (3) dispositioning contaminated water remaining in KE Basin. From the three reports, and preferred storage method, transfer method and water disposition method were defined. These consolidation methods were then evaluated against the no action alternative of continued storage using both KE and KW Basins. The report concluded that the fuel and sludge currently stored in KE Basin not be consolidated in the KW Basin, primarily due to increased cost and radiation exposure required to consolidate the fuel and sludge. Consolidation is more attractive for storage periods beyond the year 2002, which is the study period of the report

  12. Analysis of a utility-interactive wind-photovoltaic hybrid system with battery storage using neural network

    Science.gov (United States)

    Giraud, Francois

    1999-10-01

    This dissertation investigates the application of neural network theory to the analysis of a 4-kW Utility-interactive Wind-Photovoltaic System (WPS) with battery storage. The hybrid system comprises a 2.5-kW photovoltaic generator and a 1.5-kW wind turbine. The wind power generator produces power at variable speed and variable frequency (VSVF). The wind energy is converted into dc power by a controlled, tree-phase, full-wave, bridge rectifier. The PV power is maximized by a Maximum Power Point Tracker (MPPT), a dc-to-dc chopper, switching at a frequency of 45 kHz. The whole dc power of both subsystems is stored in the battery bank or conditioned by a single-phase self-commutated inverter to be sold to the utility at a predetermined amount. First, the PV is modeled using Artificial Neural Network (ANN). To reduce model uncertainty, the open-circuit voltage VOC and the short-circuit current ISC of the PV are chosen as model input variables of the ANN. These input variables have the advantage of incorporating the effects of the quantifiable and non-quantifiable environmental variants affecting the PV power. Then, a simplified way to predict accurately the dynamic responses of the grid-linked WPS to gusty winds using a Recurrent Neural Network (RNN) is investigated. The RNN is a single-output feedforward backpropagation network with external feedback, which allows past responses to be fed back to the network input. In the third step, a Radial Basis Functions (RBF) Network is used to analyze the effects of clouds on the Utility-Interactive WPS. Using the irradiance as input signal, the network models the effects of random cloud movement on the output current, the output voltage, the output power of the PV system, as well as the electrical output variables of the grid-linked inverter. Fourthly, using RNN, the combined effects of a random cloud and a wind gusts on the system are analyzed. For short period intervals, the wind speed and the solar radiation are considered as

  13. Efficient IEC permanent-magnet motor (3 kW) - Final report; Effizienter IEC Permanent-Magnet-Motor (3 kW) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H. P.; Evequoz, B. [Haute Ecole valaisanne, Sion (Switzerland); Salathe, D. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland)

    2008-04-15

    Efficient permanent-magnet motors achieve in the area up to 100 kW a higher efficiency than induction machines (standard motors). A simple and fast energy saving option is the exchange of inefficient standard motors. The objective of this work is to install a 3 kW permanent-magnet motor in a standard IEC housing and the optimization of the design for high efficiency. Another objective is the development and the realization of an efficient variable speed control. The efficiency of the motor and the inverter with the control system must be demonstrated by tests. These tasks have been split between Circle Motor AG and the universities of applied sciences of Valais and Lucerne. Considering high-efficiency and low manufacturing cost, a brushless DC solution was adopted. This resulted in an optimum design of the motor and the control system realized with a three-phase rectifier, a buck converter with variable DC voltage, and a three-phase inverter feeding full positive and negative current to two of the legs simultaneously. The maximum measured efficiency is about 96.5% for the inverter and 92% for the motor. With the advantage of the variable speed operation, the efficiency of the realized 3 kW permanent magnet motor together with the control system is always higher than the efficiency of a measured class EFF1 induction motor, even with a direct connection to the grid. The permanent-magnet motor is also about 10 kg lighter. The cost calculation shows that the permanent-magnet motor can be competitive with the induction motor when speed control is desired. This is also the domain with the largest potential for energy savings from variable speed pumps, compressors, fans. (author)

  14. SWGELLA DYSENTERIAE TYPE 1 IN KwAZuLU-NATAL

    African Journals Online (AJOL)

    -control. 1995: 15. ure co. LABORATORY SURV~ILLAN.CEOF. SWGELLA DYSENTERIAE TYPE 1 IN. KwAZuLU- ... freeze-dried quality-eontrol specimens were prepared containing ... (National Committee for Clinical Laboratory Standards,.

  15. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    Energy Technology Data Exchange (ETDEWEB)

    Smart, Gavin [Offshore Renewable Energy Catapult, Blyth, Northumberland (United Kingdom); Smith, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Warner, Ethan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sperstad, Iver Bakken [SINTEF Energy Research, Trondheim (Norway); Prinsen, Bob [Ecofys, Utrecht (Netherlands). TKI Wind Op Zee; Lacal-Arantegui, Roberto [European Commission Joint Research Centre (JRC), Brussels (Belgium)

    2016-06-02

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. The wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.

  16. Low Voltage Ride-Through Capability Solutions for Permanent Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Victor F. Mendes

    2016-01-01

    Full Text Available Due to the increasing number of wind power plants, several countries have modified their grid codes to include specific requirements for the connection of this technology to the power system. One of the requirements is the ride-through fault capability (RTFC, i.e., the system capability to sustain operation during voltage sags. In this sense, the present paper intends to investigate the behavior of a full-converter wind generator with a permanent magnet synchronous machine during symmetrical and asymmetrical voltage sags. Two solutions to improve the low voltage ride-through capability (LVRT of this technology are analyzed: discharging resistors (brake chopper and resonant controllers (RCs. The design and limitations of these solutions and the others proposed in the literature are discussed. Experimental results in a 34 kW test bench, which represents a scaled prototype of a real 2 MW wind conversion system, are presented.

  17. Design of the new Risoe-A1 airfoil family for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Fuglsang, P; Dahl, K S [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1999-03-01

    A new airfoil family for wind turbines was developed by use of a design method using numerical optimization and the flow solver, XFOIL. The results were evaluated with the Navier-Stokes solver EllipSys2D. The airfoil family constitutes 6 airfoils ranging in thickness from 15% to 30%. The airfoils were designed to have a maximum lift coefficient around 1.5 in natural conditions and high lift-drag ratios below maximum lift. Insensitivity to leading edge roughness was obtained by securing that transition from laminar to turbulent flow on the suction side occurred close to the leading edge just before stall. The airfoil family was designed for a 600 kW wind turbine and provides a basis for further enhancing the characteristics of airfoils for wind turbines and to tailor airfoils for specific rotor sizes and power regulation principles. (au) EFP-95; EFP-98. 16 refs.

  18. A Vertical-Axis Off-Grid Squirrel-Cage Induction Generator Wind Power System

    Directory of Open Access Journals (Sweden)

    Peifeng Xu

    2016-10-01

    Full Text Available In order to broaden the limited utilization range of wind power and improve the charging and discharging control performance of the storage battery in traditional small wind power generation systems, a wind power system based on a vertical-axis off-grid induction generator is proposed in this paper. The induction generator not only can run in a wide wind speed range but can also assist the vertical-axis wind turbine to realize self-starting at low wind speed. Combined with the maximum power point tracking method, the slip frequency control strategy is employed to regulate the pulse width modulation (PWM converter to control the output power of the proposed system when the wind speed and load change. The charge and discharge of the storage battery is realized by the segmented current-limiting control strategy by means of an electric power unloader device connected to the DC bus. All these implement a balanced and stable operation of the proposed power generation system. The experimental research on the 5.5 kW prototype system is developed, and the corresponding results verify the correctness and feasibility of the system design and control strategy. Some comparison experiments with a magnetic suspension permanent magnet synchronous generator (PMSG demonstrate the application prospect of the proposed vertical-axis off-grid induction generator wind power system.

  19. THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2

    Directory of Open Access Journals (Sweden)

    M. A. Korotkevich

    2017-01-01

    Full Text Available The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs, but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures, which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW. The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW and solid (110 kW cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.

  20. Butinge Wind Power Plant - Pre-engineering

    Energy Technology Data Exchange (ETDEWEB)

    Mollestad, Knut A.

    1997-03-01

    A preliminary study has been done for a wind farm at Butinge in Lithuania consisting of six 600 kW wind turbines. The location of the wind farm is planned near the border with Latvia and near the coast of the Baltic Sea. The preliminary study has through a relatively detailed technical examination of the project, primarily aimed at gathering basic data for budget estimation and cost calculations. Other relevant aspects of the project are also considered. These include an examination of the basis for the project, an analysis of wind conditions, consideration of the various environmental conditions, discussion about the form of organisation and division of responsibility, as well as an examination of the operational and maintenance framework. Based on wind measurements taken at IFE (Institute for Energy Technology), the annual mean wind is estimated to be 7.3 m/s at 45 m height (equivalent to the hub height for the proposed wind turbines). A production calculation has also been done, which shows that the total energy production of the entire wind farm is expected to 9.47 GWh per year. This is equivalent to a use time of 2630 hours respective to a load factor of 30%. The total cost is estimated at 30.2 mill NOK, and the energy price (including operational costs) delivered from the ''power plant wall'', based on this figure and the production estimate, is calculated at 0,32 NOK/kWh. This is based on a lifetime of 20 years for the facility and a 6.5% required rate of return. In addition, there is outlined a possible financial solution based on various price-scenarios and support arrangements. With an equity capital of 8% and 28% external support, the project meets the current energy price in Lithuania (3,4 US cents/kWh). Without support the sales price of the produced energy is increased by approx. 50%. (author)

  1. Effects of the Tunoe Knob offshore wind farm on birdlife

    International Nuclear Information System (INIS)

    Guillemette, M.; Kyed Larsen, J.; Clausager, I.

    1997-01-01

    As part of the plans of the Danish government to expand offshore wind energy production, The Ministry of Environment and Energy, in collaboration with the Danish power companies, initiated a three-year study of the effects of the Tunoe Knob offshore wind farm on bird life. The aim of this study was to investigate the potential conflict between offshore wind farms and water birds. Danish coastal waters support very large, internationally important concentrations of moulting, migrating and wintering water birds which depend on shallow water areas as major feeding habitats. The wind farm was established at Tunoe Knob, a shoal in Aarhus Bugt, and consisted of ten 500 kW turbines erected in 3-5 m of water during the late summer of 1995. All studies were carried out during the winter period, and results are reported for eider Somateria mollissima and common scoter Melanitta nigra, which composed the great majority of the bird population. In the part of Tunoe knob where the wind farm was build, eider numbers decreased markedly over the study period. However, this decline was comparable to that observed on other parts of Tunoe Knob. Furthermore, detailed mapping showed a high degree of annual and within season variation in spatial distribution over the area, including occurrence in the immediate vicinity of the wind farm. These results suggest that the observed changes in eider numbers in the wind farm area were due to natural variation. (EG) 21 refs

  2. 2015 Wind Technologies Market Report

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ryan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Electricity Markets and Policy Group; Bolinger, Mark [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Electricity Markets and Policy Group; Barbose, Galen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Darghouth, Naim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hoen, Ben [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mills, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rand, Joe [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Millstein, Dev [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Porter, Kevin [Exeter Associates, Columbia, MD (United States); Widiss, Rebecca [Exeter Associates, Columbia, MD (United States); Oteri, Frank [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tegen, Suzanne [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-03

    trends in project performance, wind turbine transaction prices, installed project costs, and operations and maintenance (O&M) expenses. It also reviews the prices paid for wind power in the United States and how those prices compare to short-term wholesale electricity prices and forecasts of future natural gas prices. Next, the report examines policy and market factors impacting the domestic wind power market, including federal and state policy drivers as well as transmission and grid integration issues. The report concludes with a preview of possible near-term market developments. This edition of the annual report updates data presented in previous editions while highlighting key trends and important new developments from 2015. The report concentrates on larger, utility-scale wind turbines, defined here as individual turbines that exceed 100 kW in size.

  3. Review of 2 kW grid connected LOPF tests in Nissum Bredning

    DEFF Research Database (Denmark)

    Margheritini, Lucia

    This report has been prepared by Per Resen and Aalborg University for the ForskVE project 10878: 2 kW grid connected LOPF test buoy. AAU has the role of reviewing and advise on the data analysis, besides compiling this report. The purpose of this project was to document the mechanical power...... production against a target power curve of a 2kW grid connected wave energy buoy in Nissum Bredning at Helligsø....

  4. Design of 28 GHz, 200 kW Gyrotron for ECRH Applications

    Science.gov (United States)

    Yadav, Vivek; Singh, Udaybir; Kumar, Nitin; Kumar, Anil; Deorani, S. C.; Sinha, A. K.

    2013-01-01

    This paper presents the design of 28 GHz, 200 kW gyrotron for Indian TOKAMAK system. The paper reports the designs of interaction cavity, magnetron injection gun and RF window. EGUN code is used for the optimization of electron gun parameters. TE03 mode is selected as the operating mode by using the in-house developed code GCOMS. The simulation and optimization of the cavity parameters are carried out by using the Particle-in-cell, three dimensional (3-D)-electromagnetic simulation code MAGIC. The output power more than 250 kW is achieved.

  5. Measured effects of wind turbine generation at the Block Island Power Company

    Science.gov (United States)

    Wilreker, V. F.; Smith, R. F.; Stiller, P. H.; Scot, G. W.; Shaltens, R. K.

    1984-01-01

    Data measurements made on the NASA MOD-OA 200-kw wind-turbine generator (WTG) installed on a utility grid form the basis for an overall performance analysis. Fuel displacement/-savings, dynamic interactions, and WTG excitation (reactive-power) control effects are studied. Continuous recording of a large number of electrical and mechanical variables on FM magnetic tape permit evaluation and correlation of phenomena over a bandwidth of at least 20 Hz. Because the wind-power penetration reached peaks of 60 percent, the impact of wind fluctuation and wind-turbine/diesel-utility interaction is evaluated in a worst-case scenario. The speed-governor dynamics of the diesel units exhibited an underdamped response, and the utility operation procedures were not altered to optimize overall WTG/utility performance. Primary findings over the data collection period are: a calculated 6.7-percent reduction in fuel consumption while generating 11 percent of the total electrical energy; acceptable system voltage and frequency fluctuations with WTG connected; and applicability of WTG excitation schemes using voltage, power, or VARS as the controlled variable.

  6. The effect of the Sep wind park near Oosterbierum, Friesland, The Netherlands, on birds

    International Nuclear Information System (INIS)

    Winkelman, J.E.

    1992-01-01

    The title study concerns the period 1984-1991. The wind park consists of 18 three-bladed 300 kW horizontal axis wind turbines of 35 meters height, and a rotor diameter of 30 meters, seven meteorological towers, and three cluster and control buildings. Aspects studied included disturbance of breeding, resting or feeding, and migrating birds, behavior of birds approaching the wind turbines during the day and night, and bird victims due to collision with the wind turbines and the meteorological towers. In this report attention is paid to the disturbance of the bird's biotope. The results show that four species of grassland birds, breeding in the park, were hardly disturbed by the wind turbines. For feeding and resting birds, however, disturbance effects were noted, even at a distance of 500 meters from the outside wind turbine array. The present number of bird species reduced 60-95%, dependent on the species, after the wind park was put into operation. Also the behavior of migrating birds was influenced by the wind park, showed in clustering of groups or avoiding the wind park, sometimes up to 67% of the birds did so. It is therefore recommended not to implement new wind parks in important bird migration and bird feeding or bird resting areas. Bird popular areas, however, are mostly windy areas. 15 figs., 25 tabs., 56 app., 128 refs

  7. Performance and Feasibility Analysis of a Wind Turbine Power System for Use on Mars

    Science.gov (United States)

    Lichter, Matthew D.; Viterna, Larry

    1999-01-01

    A wind turbine power system for future missions to the Martian surface was studied for performance and feasibility. A C++ program was developed from existing FORTRAN code to analyze the power capabilities of wind turbines under different environments and design philosophies. Power output, efficiency, torque, thrust, and other performance criteria could be computed given design geometries, atmospheric conditions, and airfoil behavior. After reviewing performance of such a wind turbine, a conceptual system design was modeled to evaluate feasibility. More analysis code was developed to study and optimize the overall structural design. Findings of this preliminary study show that turbine power output on Mars could be as high as several hundred kilowatts. The optimized conceptual design examined here would have a power output of 104 kW, total mass of 1910 kg, and specific power of 54.6 W/kg.

  8. Atmospheric air density analysis with Meteo-40S wind monitoring system

    Directory of Open Access Journals (Sweden)

    Zahariea Dănuţ

    2017-01-01

    Full Text Available In order to estimate the wind potential of wind turbine sites, the wind resource maps can be used for mean annual wind speed, wind speed frequency distribution and mean annual wind power density determination. The general evaluation of the wind resource and the wind turbine ratings are based on the standard air density measured at sea level and at 15°C, ρs=1.225 kg/m3. Based on the experimental data obtained for a continental climate specific location, this study will present the relative error between the standard air density and the density of the dry and the moist air. Considering a cold day, for example on Friday 10th February 2017, on 1-second measurement rate and 10-minute measuring interval starting at 16:20, the mean relative errors obtained are 10.4145% for dry air, and 10.3634% for moist air. Based on these results, a correction for temperature, atmospheric air pressure and relative humidity should be always considered for wind resource assessment, as well as for the predicting the wind turbines performance.

  9. Performance of the 1 kW thermoelectric generator for diesel engines

    International Nuclear Information System (INIS)

    Bass, J.C.; Elsner, N.B.; Leavitt, F.A.

    1994-01-01

    Hi-Z Technology, Inc. (Hi-Z) has been developing a 1 kW thermoelectric generator for class eight Diesel truck engines under U.S. Department of Energy and California Energy Commission funding since 1992. The purpose of this generator is to replace the currently used shaft-driven alternator by converting part of the waste heat in the engine's exhaust directly to electricity. The preliminary design of this generator was reported at the 1992 meeting of the XI-ICT in Arlington, Texas. This paper will report on the final mechanical, thermal and thermoelectric design of this generator. The generator uses seventy-two of Hi-Z's 13 Watt bismuth-telluride thermoelectric modules for energy conversion. The number of modules and their arrangement has remained constant through the program. The 1 kW generator was tested on several engines during the development process. Many of the design features were changed during this development as more information was obtained. We have only recently reached our design goal of 1 kW output. The output parameters of the generator are reported. copyright 1995 American Institute of Physics

  10. Cost-efficient foundation structures for large offshore wind farms

    International Nuclear Information System (INIS)

    Birch, C.; Gormsen, C.; Lyngesen, S.; Rasmussen, J. L.; Juhl, H.

    1997-01-01

    This paper presents the results of the development of a cost-efficient foundation for large (1.5 MW) offshore wind farms at water depth of 5 to 11 m. Previously, medium sized wind turbines (500 kW) in Denmark have been installed offshore at water depths of approximately 5 m on concrete gravity foundations. The installation of larger turbines at greater depth does, however, hold great promise in terms of wind environment and environmental considerations. The costs of a traditional gravity foundation at these increased water depths is expected to be prohibitive, and the aim of the project has been to reduce the foundations costs in general. This paper describes the theoretical basis for the geotechnical and structural design of three alternative concepts and presents an optimised layout of each based on a research and development project. The basis has been a wind farm consisting of 100 turbines. The R and D project has been undertaken by the consulting engineers Nellemann, Nielsen and Rauschenberger A/S (Gravity foundation), LICengineering A/S (Mono pile) and Ramboell (Tripod) in co-operation with the Danish utility engineering companies Elkraft and Elsamprojekt A/S. The project was partly financed by the participants and by the Danish Energy Agency through their 1996 Energy Research Programme (EFP-96). (au) 18 refs

  11. Dynamical Investigation of Asteroid 66391 (1999 KW4)

    Science.gov (United States)

    Scheeres, Daniel J.; Fahnestock, E. G.; Ostro, S. J.; Margot, J. L.; Benner, L. A.; Broschart, S. B.; Bellerose, J.; Giorgini, J. D.; Nolan, M. C.; Magri, C.; Pravec, P.; Scheirich, P.; Rose, R.; Jurgens, R. F.; Suzuki, S.; DeJong, E. M.

    2006-09-01

    Radar imaging and simulation of the binary near-Earth asteroid 66391 (1999 KW4) reveals a system with highly unusual physical and dynamical properties (Ostro et al., DPS 2006). Classical treatments and previous analyses of binary-system dynamics have made assumptions about the component shapes that are not valid for the KW4 system. We have explored the full dynamics of the KW4 system via numerical simulations that solve the equations of motion for the coupled evolution of orbit and rotation, using radar-derived physical models, and using dynamical constraints from the observations to guide our initial conditions. Our simulations model the translational (or orbital) dynamics as the relative motion between the body centers of mass and model the rotational dynamics using the Euler equations and attitude kinematic equations for each body. All the equations are driven by the mutual gravitational potential, which is an explicit function of the relative position and attitude of the two bodies. Propagation of the system's dynamical evolution over time spans of months has been made tractable by using a novel variational integrator that requires only one evaluation per time step but conserves the symplectic properties of the dynamical system, and by implementing the evaluations on a parallel computer, using up to 256 processors. Our simulations use the component shapes, masses, and average orbit as initial conditions for integrations of the components' spins and mutual orbit, taking into consideration the actual gravitational potentials produced by the model shapes and the coupling between the components' motions. Our results reveal this NEA to have extraordinary physical and dynamical properties, which suggest intriguing possibilities for formation and evolution mechanisms.

  12. The effect of wind turbines on the bird population at Blyth Harbour

    International Nuclear Information System (INIS)

    Still, D.; Little, B.; Lawrence, S.

    1996-01-01

    Bird monitoring was carried out at Blyth Harbour Wind Farm which consists of a line of nine 300kW wind turbines distributed at 200m intervals along a 1.2km breakwater. The harbour breakwater is designated as part of a Site of Special Scientific Interest as it supports an internationally important winter population of Purple Sandpipers. The Blyth estuary is to be designated as part of a Special Protection Area under the EC Habitats Directive and as part of a proposed RAMSAR site due to its peak periods up to c.5000 bird movements/day occur adjacent to the windfarm. Mortality surveys (at one week intervals) were carried out on adjacent beaches to the wind farm in order to assess the background numbers of bird corpses and locate wind farm casualties. Supplementary mortality searches were carried out near power lines less than 2.5 km upstream from the wind farm. Tests of the efficiency of the mortality surveys have been carried out in order to assess the likely impact on the local bird populations. In spite of the large bird population supported by the harbour and its close proximity to the wind farm there have been relatively few collision victims (31) since the windfarm was commissioned. This is equivalent to less than 1.34 bird strike/wind turbine per annum. (author)

  13. Effect of unbalanced voltage on windings temperature, operational life and load carrying capacity of induction machine

    Energy Technology Data Exchange (ETDEWEB)

    Gnacinski, P. [Gdynia Maritime University, Department of Ship Electrical Power Engineering, Morska Street 83, 81-225 Gdynia (Poland)

    2008-04-15

    This paper investigates the influence of the CVUF angle on the windings temperature rise and the derating factor of an induction machine supplied with unbalanced voltage. The effect of simultaneous voltage unbalance and harmonics on its operational life is analyzed as well. The results of calculations and experimental investigations are presented for two induction cage machines of rated power 3 and 5.5 kW. (author)

  14. A novel steady state wind turbine simulator using an inverter controlled induction motor

    Energy Technology Data Exchange (ETDEWEB)

    Kojabadi, H.M.; Liuchen Chang

    2005-07-01

    This paper presents a new wind turbine simulator for steady state conditions. In order to provide a test platform for wind turbine drive trains, the authors have developed an experimental system to simulate the static characteristics of real wind turbines. This system consists of a 10 hp induction motor (IM), which drives a synchronous generator and is driven by a 10 kW variable-speed drive inverter, and real time control software. A microcontroller, a PC interfaced to a LAB Windows I/O board, and an IGBT inverter-controlled induction motor are used instead of a real wind turbine to supply shaft torque. A control program written in the C language is developed that obtains wind profiles and, by using turbine characteristics and the rotational speed of the IM, calculates the theoretical shaft torque of a real wind turbine. Based on the comparison of the measured torque with this demand torque, the shaft torque of the IM is regulated accordingly by controlling stator current demand and frequency demand of an inverter. In this way, the relationships between shaft rotating speed, shaft torque of the IM and wind speed are made to conform to the characteristics of a real wind turbine. The drive is controlled using the measured shaft torque directly, instead of estimating it as conventional drives do. (author)

  15. A wind-PV-battery hybrid power system at Sitakunda in Bangladesh

    International Nuclear Information System (INIS)

    Nandi, Sanjoy Kumar; Ghosh, Himangshu Ranjan

    2009-01-01

    The measured wind data of Local Government Engineering Department (LGED) for 2006 at 30 m height shows a good prospect for wind energy extraction at the site. For a few months and hours the speed is below the cut in speeds of the available turbines in the market. The predicted solar radiation data from directly related measured cloud cover and sunshine duration data of Bangladesh Meteorological Department (BMD) for 1992-2003 indicates that a reliable power system can be developed over the year if the solar energy technology is merged with the wind energy technologies for this site. This research work has studied on optimization of a wind-photovoltaic-battery hybrid system and its performance for a typical community load. The assessment shows that least cost of energy (COE) is about USD 0.363/kWh for a community using 169 kWh/day with 61 kW peak and having minimum amount of access or unused energy. Moreover, compared to the existing fossil fuel-based electricity supply, such an environment friendly system can mitigate about 25 t CO 2 /yr. The analysis also indicates that wind-PV-battery is economically viable as a replacement for conventional grid energy supply for a community at a minimum distance of about 17 km from grid.

  16. Noise annoyances from wind power: Survey of the population living close to a wind power plant. Final report: Part 3 Main study; Stoerningar fraan vindkraft: undersoekning bland maenniskor boende i naerheten av vindkraftverk. Slutrapport: Del 3 Huvudstudie

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Eja [Halmstad Univ., Halmstad (Sweden). School of Business and Engineering; Persson-Waye, K [Goeteborg Univ., Goeteborg (Sweden). Dept. of Environmental Medicine

    2002-02-01

    To evaluate the occurrence of annoyance from wind turbines, a study was performed in Laholm in May 2000. The aim was to obtain dose response relationships between calculated sound levels and noise annoyance and appropriate sound description as well as analysing the influence of other variables on noise annoyance. A questionnaire survey was performed in 6 areas comprising 16 wind turbines, of which 14 had an effect of 600 kW. The purpose of the study was masked. Among questions on living conditions in the countryside, questions directly related to wind turbines were included. The study population (n=518) comprised one randomly selected subject between the ages of 18 to 75 years in each household living within a calculated wind turbine sound level of 25 to 40 dBA. The response rate was 68.7% (n=356). Calculated distributions of A-weighted sound level were performed for each area and plotted on geographical maps in 2.5 dBA steps. Each dwelling could thus be given a sound level within an interval of 2.5 dBA. The most frequently occurring source of noise annoyance was noise from rotor blades. The proportions of respondents annoyed by noise increased with calculated sound level. Among respondents exposed to sound levels of 35.0-37.5 dBA, 43% responded themselves to be rather or much annoyed. A-weighted sound level was only one variable explaining annoyance. Annoyance was correlated to a larger extent by the intrusiveness of the sound character swishing. Noise annoyance was interrelated to the respondents' opinion of the visual impact of wind turbines, while attitude towards wind power in general had no greater influence. Disturbance of spoilt view was reported to a similar degree as noise disturbance. Further investigations are needed to clarify factors of importance for the disturbance of view. All the wind turbines in the study had constant rotation speed. The greater wind turbines that are now erected often have variable speed, which may lead to a sound comprising

  17. Economic optimisation of a wind power plant for isolated locations

    International Nuclear Information System (INIS)

    Fortunato, B.; Mummolo, G.; Cavallera, G.

    1997-01-01

    This paper presents a model of a wind power plant for isolated locations composed of a vertical axis wind turbine connected to a self-excited induction generator operating at constant voltage and frequency; a back-up diesel generator and a battery system are moreover included in the system. Constant voltage and frequency are obtained only by controlling the generator appropriately. The control system is supposed to be optimised so that the system operates at the highest efficiency. In order to improve the total efficiency even further, a gear-box to vary the gear transmission ratio between the turbine and the generator has been considered. A ''Monte Carlo'' type simulation has been used to analyse the operation of that system over a one year period. The model is based on a probability density function of the wind speed derived by statistical data concerning a given location and on the probabilistic curve of the load required by an isolated location. The cost per kW h for different dimensions of the main components has been evaluated and the optimum configuration has been identified. (author)

  18. Small Wind Turbine Technology Assessment

    International Nuclear Information System (INIS)

    Avia Aranda, F.; Cruz Cruz, I.

    1999-01-01

    The result of the study carried out under the scope of the ATYCA project Test Plant of Wind Systems for Isolated Applications, about the state of art of the small wind turbine technology (wind turbines with swept area smaller than 40 m 2 ) is presented. The study analyzes the collected information on 60 models of wind turbines from 23 manufacturers in the worldwide market. Data from Chinese manufacturers, that have a large participation in the total number of small wind turbines in operation, are not included, due to the unavailability of the technical information. (Author) 15 refs

  19. Suitability analysis of wind energy development on brownfields, landfills and industrial sites in the city of Chicago

    Science.gov (United States)

    Fyodorova, Valeryia A.

    In 2011 renewable energy generated only about 5% of total U.S. electricity and 3% came from wind power. Wind power is the oldest and fastest growing renewable energy, and U.S. Department of Energy (DOE) anticipates that by 2030 the potential of the U.S. to generate wind power will rise up to 20% (National Renewable Energy Laboratory 2008). Currently, the rural areas serve as the primary choice of wind turbine installation because there are less wind obstacles that create wind turbulence, which in turn is disruptive for the proper functioning of the wind turbines, and allows more laminar (streamline) wind flow. However according to various literatures, the installation of wind turbines in rural areas has its drawbacks. The infrastructure is underdeveloped and usually the selected sites require the construction of new roads and transmission lines. The new construction and occasional deforestation lead to soil erosion and environmental degradation. On top of that transporting energy to cities that are the primary consumers of wind energy results in energy transmission loss. Urban areas, on the other hand, have well developed infrastructure, and the installation of turbines on abandoned and contaminated urban lands which are expensive to clean and rehabilitate for other uses would lower installation costs and would have little environmental degradation effect. The objective of this research was to provide a preliminary wind power suitability analysis for installing medium (100 -1000 kW) and large (1000 - 3000 kW) size wind turbines in urban areas, such as city of Chicago. Geographic Information Systems (GIS) and a multi attribute Weighted Linear Combination (WLC) method that is based on the concept of weighted average were primary tools utilized to conduct the analysis. The criteria that were used to select suitable sites were the same criteria used for rural wind farms, such as wind speeds, historic landmarks, avian and wildlife habitat, conservation lands, proximity

  20. Fiscal 2000 report on result of international joint demonstrative development of photovoltaic power generation system. Demonstrative research on photovoltaic power generation system interconnection system (Myanmar); 2000 nendo taiyoko hatsuden system kokusai kyodo jissho kaihatsu seika hokokusho. Taiyoko hatsuden keito renkei system jissho kenkyu (Myanmar)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Joint research was conducted with Myanmar on a photovoltaic power generation system interconnection system, for which fiscal 2000 results were described in this paper. Power generating facilities were set up consisting of 80kW photovoltaic, 40kW wind and 60kW diesel systems. With the photovoltaic and wind power generation connected to a small-scale power system as a ballast load, the system interconnection is formed through load adjusting equipment such as storage batteries. The hybrid system feeding is from 6 o'clock early in the morning until 23 late at night. The diesel power generation is free from restrictions. The operating method was set on system control (demand side management) by adjustment from the load side, with ballast load control employed that adjustably operates an ice machine load. The basic design was drafted in terms of a storage battery capacity of 1,000Ah and an ice machine load of 32kW. The daytime load was assumed to be 25% of the night load. On the equipment specifications set in this basic design, arrangement design was conducted for the equipment in the premises, making a land development plan and a basic construction plan including a temporary work site, construction steps, transportation and delivery of the equipment. Quantity of solar radiation and wind data were continuously observed. (NEDO)

  1. Wind measurements with SODAR during strong temperature inversions near the ground

    International Nuclear Information System (INIS)

    Thomas, P.; Vogt, S.

    1989-08-01

    SODAR (Sound Detection and Ranging) equipment has been increasingly used to measure vertical wind profiles with little expenditure in terms of staff, continuously over time and with a good spatial resolution. These informations serve as input variables for atmospheric transport and dispersion models, environmental monitoring of industrial facilities and, generally, for investigating a broad spectrum of meteorological phenomena. The SODAR principle has proved its suitability since long provided that the data recorded with SODAR have served to establish wind statistics valid for extended periods of time. At industrial sites potentially releasing substances prejudicial to health, e.g., chemical plants, nuclear power plants, etc., a SODAR must, moreover, be capable of measuring reliable the wind conditions also during short periods of release. This would, e.g., be important during accidental releases. Especially interesting situations for pollutant dispersion are distinct temperature inversions. It will be examined in this paper whether a SODAR is capable of measuring reliably the wind conditions also during those inversions. The selection of the situations of inversion as well as the direct intercomparison of data supplied by SODAR and conventional wind measuring instruments (anemometer and wind vane) are possible at the 200 m meteorological tower erected at the Karlsruhe Nuclear Research Center. The comparison between SODAR and the meteorological tower has shown that a SODAR is able to measure reliably the wind data also in situations characterized by strong ground-based and elevated inversions, respectively. (orig./KW) [de

  2. Performance and Economics of a Wind-Diesel Hybrid Energy System: Naval Air Landing Field, San Clemente Island, California; TOPICAL

    International Nuclear Information System (INIS)

    McKenna, Ed; Olsen, Timothy

    1999-01-01

    This report provides an overview of the wind resource, economics and operation of the recently installed wind turbines in conjunction with diesel power for the Naval Air Landing Field (NALF), San Clemente Island (SCI), California Project. The primary goal of the SCI wind power system is to operate with the existing diesel power plant and provide equivalent or better power quality and system reliability than the existing diesel system. The wind system is also intended to reduce, as far as possible, the use of diesel fuel and the inherent generation of nitrogen-oxide emissions and other pollutants. The first two NM 225/30 225kW wind turbines were installed and started shake-down operations on February 5, 1998. This report describes the initial operational data gathered from February 1998 through January 1999, as well as the SCI wind resource and initial cost of energy provided by the wind turbines on SCI. In support of this objective, several years of data on the wind resources of San Clemente Island were collected and compared to historical data. The wind resource data were used as input to economic and feasibility studies for a wind-diesel hybrid installation for SCI

  3. Optimal Locations for Siting Wind Energy Projects: Technical Challenges, Economics, and Public Preferences

    Science.gov (United States)

    Lamy, Julian V.

    40 TWh of new wind generation in the Midwestern transmission system (MISO) while minimizing system costs. Results show that building wind farms in North/South Dakota (windiest states) compared to Illinois (less windy, but close to population centers) would only be economical if the incremental transmission costs to access them were below 360/kW of wind capacity (break-even value). Historically, the incremental transmission costs for wind development in North/South Dakota compared to in Illinois are about twice this value. However, the break-even incremental transmission cost for wind farms in Minnesota/Iowa (also windy states) is 250/kW, which is consistent with historical costs. I conclude that for the case in MISO, building wind projects in more distant locations (i.e., Minnesota/Iowa) is most economical. My two final chapters use semi-structured interviews (Chapter 4) and conjoint-based surveys (Chapter 5) to understand public perceptions and preferences for different wind project siting characteristics such as the distance between the project and a person's home (i.e., "not-in-my-backyard" or NIMBY) and offshore vs. onshore locations. The semi-structured interviews, conducted with members of a community in Massachusetts, revealed that economic benefit to the community is the most important factor driving perceptions about projects, along with aesthetics, noise impacts, environmental benefits, hazard to wildlife, and safety concerns. In Chapter 5, I show the results from the conjoint survey. The study's sample included participants from a coastal community in Massachusetts and a U.S.-wide sample from Amazon's Mechanical Turk. Results show that participants in the U.S.-wide sample perceived a small reduction in utility, equivalent to $1 per month, for living within 1 mile of a project. Surprisingly, I find no evidence of this effect for participants in the coastal community. The most important characteristic to both samples was the economic benefits from the

  4. Performance testing of a small vertical-axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, R.; Tullis, S.; Ziada, S. [McMaster Univ., Hamilton, ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    Full-scale wind tunnel testing of a prototype 3.5 kW vertical-axis wind turbine (VAWT) was conducted in a low speed wind tunnel in Ottawa. The tests were conducted to determine nominal power curves as well as the system's structural integrity, safety and operational characteristics. Dimensionless power curves were used to assess the relation between the wind turbine's rotary speed and the produced power for various wind speeds. Tests began at the lowest wind speed and revolutions per minute (RPM) and were gradually increased. A proximity sensor was used to determine the passing frequency of spaced bolts. The aerodynamic performance of the turbine was evaluated using a servo-controlled mechanical variable load with a disc brake calliper and electro-hydraulic servo-actuator. A load cell was used to measure torque produced by the turbine. An active closed loop speed control system was used to regulate the rotary speed of the turbine. The system used a high gain proportional control law to guarantee stability. Calculated power was based on the average rotary speed measurement. Results of the study suggested that the dimensional power performance of the turbine could be predicted from the curve for all rotary speeds and for wind speeds between 8 and 16 m/s. The maximum power coefficient of 0.3 occurred at a tip speed ratio of 1.6. Test results demonstrated that the turbine reached its rated power at 14 m/s. However, the range of tip speed ratios for power production were lower than the range for most other small VAWT. 2 refs., 3 figs.

  5. Development of 1 kW Stirling cryocooler using a linear compressor

    International Nuclear Information System (INIS)

    Ko, J; Kim, H; Hong, Y J; Yeom, H; In, S; Park, S J

    2015-01-01

    Cryogenic cooling systems for HTS electric power devices require a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed a dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of the fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has a gamma-type configuration. The piston and displacer are supported with a flexure spring. A slit-type heat exchanger is adopted for the cold and warm-end, and the generated heat is rejected by cooling water. In the cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. The developed cryocooler reaches 47.8 K within 23.4 min. with no-load. Heat load tests shows a cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP. (paper)

  6. Small wind power plants : results of the Nordic wind diesel projects for large telecommunications companies; Implantation d'une centrale eolienne comme source d'energie d'appoint pour des stations de telecommunications

    Energy Technology Data Exchange (ETDEWEB)

    Ilinca, A.; Chaumel, J.L. [ATI Eolien, Rimouski, PQ (Canada); Thibault, G. [Entreprises MB, PQ (Canada)

    2005-07-01

    Two wind-diesel generating stations have been installed at telecommunication towers in the remote communities of Kuujjuarapik and Lac Julien in northern Quebec. The use of wind power contributes to the sustainable development in these remote areas by lowering the reliance on costly helicopter-transported diesel fuel and by reducing the release of greenhouse gases to the atmosphere. The technical characteristics of the Bergey 100 kW turbine with battery charger were presented along with the technical characteristics of the EolDie control panel that controls the supply of electricity from either the wind or diesel power generators. For the first time, the ATI-Wind technology system that was installed can supply the needs of the large telecommunication towers of Bell Canada and Telebec from either the wind or the diesel generators. The system is also capable of shutting down the diesel generators when wind energy is sufficient to take over. Early results from June 2005 showed that the diesel generators could be turned off for 55 per cent of the time. Preliminary results of these 2 projects were discussed by the firms in charge of the diesel and wind aspects and recommendations for improvements to the control systems were presented. 11 figs.

  7. Aspects regarding the Calculation of the Dielectric Loss Angle Tangent between the Windings of a Rated 40 MVA Transformer

    Directory of Open Access Journals (Sweden)

    Cristinel Popescu

    2015-09-01

    Full Text Available The paper aims to identify how to determine the dielectric loss angle tangent of the electric transformers from the transformer stations. Autors of the paper managed a case study on the dielectric established between high respectively medium voltage windings of an electrical rated 40 MVA transformer.

  8. Study on development system of increasing gearbox for high-performance wind-power generator

    Science.gov (United States)

    Xu, Hongbin; Yan, Kejun; Zhao, Junyu

    2005-12-01

    Based on the analysis of the development potentiality of wind-power generator and domestic manufacture of its key parts in China, an independent development system of the Increasing Gearbox for High-performance Wind-power Generator (IGHPWG) was introduced. The main elements of the system were studied, including the procedure design, design analysis system, manufacturing technology and detecting system, and the relative important technologies were analyzed such as mixed optimal joint transmission structure of the first planetary drive with two grade parallel axle drive based on equal strength, tooth root round cutting technology before milling hard tooth surface, high-precise tooth grinding technology, heat treatment optimal technology and complex surface technique, and rig test and detection technique of IGHPWG. The development conception was advanced the data share and quality assurance system through all the elements of the development system. The increasing Gearboxes for 600KW and 1MW Wind-power Generator have been successfully developed through the application of the development system.

  9. 110GHz-500kW long-pulse gyrotron with built-in quasi-optical mode converter

    International Nuclear Information System (INIS)

    Sakamoto, Keishi; Kariya, Tsuyoshi; Hayashi, Ken-ichi.

    1994-01-01

    We have designed, fabricated, and tested a 110 GHz-500 kW long-pulse gyrotron. The gyrotron incorporates a quasi-optical mode converter which transforms the oscillation mode, TE 22,2 , into a Gaussian radiation beam. The adoption of a built-in mode converter enabled us to design the electron beam collector so as to be capable of tolerating a 2 MW heat load. Attention was also paid to designing the gyrotron cavity and output window so as to permit long-pulse operations. In an experiment, we observed a maximum output power of 550 kW and achieved 1.3 s operation at a power level of 410 kW. (author)

  10. Sources and levels of background noise in the NASA Ames 40- by 80-foot wind tunnel

    Science.gov (United States)

    Soderman, Paul T.

    1988-01-01

    Background noise levels are measured in the NASA Ames Research Center 40- by 80-Foot Wind Tunnel following installation of a sound-absorbent lining on the test-section walls. Results show that the fan-drive noise dominated the empty test-section background noise at airspeeds below 120 knots. Above 120 knots, the test-section broadband background noise was dominated by wind-induced dipole noise (except at lower harmonics of fan blade-passage tones) most likely generated at the microphone or microphone support strut. Third-octave band and narrow-band spectra are presented for several fan operating conditions and test-section airspeeds. The background noise levels can be reduced by making improvements to the microphone wind screen or support strut. Empirical equations are presented relating variations of fan noise with fan speed or blade-pitch angle. An empirical expression for typical fan noise spectra is also presented. Fan motor electric power consumption is related to the noise generation. Preliminary measurements of sound absorption by the test-section lining indicate that the 152 mm thick lining will adequately absorb test-section model noise at frequencies above 300 Hz.

  11. Implementation of MRAC controller of a DFIG based variable speed grid connected wind turbine

    International Nuclear Information System (INIS)

    Abdeddaim, Sabrina; Betka, Achour; Drid, Said; Becherif, Mohamed

    2014-01-01

    Highlights: • Set-up of an experimental test emulating a wind turbine, driving a grid-connected conventional DFIG. • An optimal operation below rated speed is achieved by means of an appropriate maximum power-point tracking algorithm. • Design and implementation of an adaptive model reference controller (MRAC) of the active and reactive power regulation. - Abstract: This paper presents the design and the implementation of a model reference adaptive control of the active and reactive power regulation of a grid connected wind turbine based on a doubly fed induction generator. This regulation is achieved below the synchronous speed, by means of a maximum power-point tracking algorithm. The experiment was conducted on a 1 kW didactic wound rotor induction machine in association with a wind turbine emulator. This implementation is realized using a dSPACE 1104 single-board control and acquisition interface. The obtained results show a permanent track of the available maximum wind power, under a chosen wind speed profile. Furthermore the proposed controller exhibits a smooth regulation of the stator active and reactive power amounts exchanged between the machine and the grid

  12. A novel vertical-axis wind turbine for distributed and utility deployment

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.Y. [Inha Univ., Incheon (Korea, Republic of); Lee, S. [Inha Univ., Incheon (Korea, Republic of)]|[KR Wind Energy Research Inst., Incheon (Korea, Republic of); Sabourin, T.; Park, K. [KR Windpower Inc., (United States)

    2008-07-01

    The rapid growth in the wind power industry can be attributed to energy cost saving, power reliability, grid support, and environmental concerns. Wind turbines should also comply with community noise and aesthetic requirements as well as meet a strong need for high capacity. Wind Turbine Generator Systems are classified as either horizontal axis wind turbine (HAWT) or vertical axis wind turbine (VAWT) depending on whether their axis of rotation is parallel or perpendicular to the ground. The average electric power produced by the wind turbine is proportional to the efficiency of the rotor, air density, projected area of the turbine, and cube of wind speed. The capacity factor should be increased to guarantee the economics of the turbine via increase in the rotor size or the turbine efficiency. The low rotational speed of VAWT rotors suggests that the machine will be quieter than the high-rotational speed of HAWTs, thereby being potentially suitable for applications closer to population centres. The slow rotating machine may also be considered to be visually more aesthetic. This paper presented the measured performance of a small-scale VAWT rated as 1 kW which has a tail consisting of a stabilizer and a rudder. It was tested for its electric power produced at specified wind conditions in an open-type wind tunnel. In order to eliminate the inevitable blockage effect by the size of turbine, the flow deceleration effect of the incoming air to the turbine was analyzed through model testing and numerical simulation and implemented to the proto-type testing. The turbine and its furling tail was shown to be safe. 9 refs., 1 tab., 10 figs.

  13. Characteristics and uses of a 250 kW TRIGA reactor

    International Nuclear Information System (INIS)

    Dimic, V.

    1985-01-01

    The 250 kW TRIGA Mark II reactor is a light water reactor with solid fuel elements in which the zirconium hydride moderator is homogeneously distributed between enriched uranium. Therefore the reactor has the large prompt negative temperature coefficient of reactivity, the fuel also has very high retention of radioactive fission products. The reactor core is a cylindrical configuration with an annular graphite reflector. The experimental facilities include a rotary specimen rack, a central incore radiation thimble, a pneumatic transfer system, and pulsing capability. Other experimental facilities include two radial and two tangential beam tubes, a graphite thermal column, and a graphite thermalizing column. At the steady state power of 250 kW the peak flux is 1x10 13 n/cm 2 s in the central test position. In addition, pulsing to about 2000 MW is usually provided giving peak fluxes of about 2x10 16 n/cm 2 sec. All TRIGA reactors produce a core-average thermal neutron flux of about 10 7 n.v per watt. Only with very large accelerators could such a high neutron flux be achieved. In order to give an appreciation for the research conducted at research reactors, the types of research could be summarized as follows: thermal neutron scattering, neutron radiography, neutron and nuclear physics, activation analysis, radiochemistry, biology and medicine, and teaching and training. Typical applied research with a 250 kW reactor has been conducted in medicine in biology, archeology, metallurgy and materials science, engineering and criminology. It is well known that research reactors have been used routinely to produce isotopes for industry and medicine. In some instances, reactors are the preferred method of isotope production. We can conclude that the 250 kW TRIGA research reactor is a useful and wide ranging source of radiation for basic and applied research. The operation cost for this instrument is relatively low. (author)

  14. First Results of the IOT Based 300 kW 500 MHz Amplifier for the Diamond Light Source

    CERN Document Server

    Jensen, Morten; Maddock, Matt; Müller, Marc; Rains, Simon; Watkins, Alun V

    2005-01-01

    We present the first RF measurements of the IOT based 300 kW 500 MHz amplifier for the Diamond Light Source. Four 80 kW IOTs are combined using a waveguide combiner to achieve the RF requirement of up to 300 kW for each of three superconducting cavities for the main storage ring. The IOTs are protected by a full power circulator and a 300 kW ferrite RF load. This is the first time IOTs will be used for a synchrotron light source. This paper gives an overview of the design of the Thales amplifiers and IOTs with commissioning results including measurements of key components and overall RF performance following factory tests and the installation of the first unit

  15. Regional tendencies of extreme wind characteristics in Hungary

    Science.gov (United States)

    Radics, Dr.; Bartholy, Dr.; Péliné

    2009-09-01

    Human activities have substantial effects on climate system. It has already accepted that change in the long-term climatic mean state will have significant consequences in the global economy and society, but the most important effects of climate change may come from changes in the intensity and frequency of climatic extremes. It is therefore of great interest to document the extremes of surface wind that could assist in estimating the regional effects of climate change. The research presented is based on 34-year-long (1975-2008) wind (speed, direction, and wind gust) data sets of 36 Hungarian synoptic meteorological stations. After processing (including digitalisation of old instrumental records, quality control and homogenisation of wind time series) the measured wind data sets, time series and complex wind climate analysis were carried out. Spatial and temporal distributions of mean and extreme wind climate characteristics were estimated, wind extremes and trends were interpolated and mapped over the country. Finally, measured and reanalysed (ERA40) wind data were compared over Hungary, in order to verify not only the validity of ERA40 reanalysed data sets, but the adaptability of climate simulation results in estimation of regional climate change effects.

  16. Two year performance of a 10 kW CPV system installed in two areas of Saudi Arabia

    Science.gov (United States)

    Khonkar, Hussam; Alowais, Abdullah; Sheikho, Ayman; Alyahya, Abdulaziz; Alghamdi, Ahmed; Alsaedan, Abdullah; Eugenio, Nunilo N.; Alalweet, Fahad; Halawani, Mohammad; Alsaferan, Abdulrahman

    2014-09-01

    The three year KACST/IBM collaboration in solar technology research led to the design and development of a 10kW CPV system. The system is comprised of 81 PV modules, inverters and a tracking system and is grid connected. A primary and secondary optics were employed to reach 1600x concentration on multijunction solar cells. Two CPV trackers were installed in the city of Riyadh and one in the eastern coastal city of Al Khafji. These two areas differ in climatic conditions. Riyadh is mostly dry and very often hit by very strong sand storms while Al Khafji is very humid with sand storms. Very fine dusts and dirt carried by the storms hits the surface of the primary optics, Fresnel lens, of the system. In Riyadh, the particles stick to the lenses but accumulation in the surface is not much since it is blown away by wind. However, the humid condition of the coastal areas wets the dusts and makes it sticky, cumulating more dusts and dirt. This paper discusses in details the parts of the 10kW CPV system. It presents a comprehensive analysis of the system's performance since the time they were installed and operated. CPV systems are operated with the least number of personnel and supervision. However, dust and dirt lessens the amount of sunlight passing through the primary optics. It requires periodic cleaning of the Fresnel lens. Different methods of cleaning were tried to identify the efficient way to clean the system that results to a higher power generation. Corrections and modifications of the system to further increase power production are presented.

  17. 100KE/KW fuel storage basin surface volumetric factors

    International Nuclear Information System (INIS)

    Conn, K.R.

    1996-01-01

    This Supporting Document presents calculations of surface Volumetric factors for the 100KE and 100KW Fuel Storage Basins. These factors relate water level changes to basin loss or additions of water, or the equivalent water displacement volumes of objects added to or removed from the basin

  18. 40 CFR 89.206 - Trading.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Trading. 89.206 Section 89.206... EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Averaging, Banking, and Trading Provisions § 89.206 Trading. (a) Requirements for Tier 1 engines rated at or above 37 kW. (1) A nonroad...

  19. 40 CFR 89.205 - Banking.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Banking. 89.205 Section 89.205... EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Averaging, Banking, and Trading Provisions § 89.205 Banking. (a) Requirements for Tier 1 engines rated at or above 37 kW. (1) A manufacturer...

  20. Design of the 50 kW neutron converter for SPIRAL2 facility

    Energy Technology Data Exchange (ETDEWEB)

    Avilov, M.S. [Budker Institute of Nuclear Physics, 630090 Novosibirsk, SB RAS (Russian Federation); Tecchio, L.B., E-mail: tecchio@lnl.infn.i [Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Titov, A.T. [Boreskov Institute of Catalysis, 630090 Novosibirsk, SB RAS (Russian Federation); Tsybulya, V.S. [Trofimuk Institute of Geology, 630090 Novosibirsk, SB RAS (Russian Federation); Zhmurikov, E.I. [Budker Institute of Nuclear Physics, 630090 Novosibirsk, SB RAS (Russian Federation)

    2010-06-21

    SPIRAL2 is a facility for the study of fundamental nuclear physics and multidisciplinary research. SPIRAL2 represents a major advance for research on exotic nuclei. The radioactive ion beam (RIB) production system is comprised of a neutron converter, a target and an ion source. This paper is dedicated to the designing of the 50 kW neutron converter for the SPIRAL2 facility. Among the different variants of the neutron converter, the one based on a rotating solid disk seems quite attractive due to its safety, ease in production and relatively low cost. Dense graphite used as the converter's material allows the production of high-intensity neutron flux and, at the same time, the heat removal from the converter by means of radiation cooling. Thermo-mechanical simulations performed in order to determine the basic geometry and physical characteristics of the neutron production target for SPIRAL2 facility, to define the appropriate beam power distribution, and to predict the target behaviour under the deuteron beam of nominal parameters (40 MeV, 1.2 mA, 50 kW) are presented. To study the main physical and mechanical properties and serviceability under operating conditions, several kinds of graphite have been analyzed and tested. The paper reports the results of such measurements. Radiation damage is the most important issue for the application of graphite as neutron converter. It is well known that the thermal conductivity of the neutron-irradiated graphite is reduced by a factor of 10 from the initial value after irradiation. Difference in volume expansions between the matrix and the fiber results in serious damage of neutron-irradiated C/C composites. Calculations showed that at high temperature the effect of neutron radiation is not so critical and that the change in thermal conductivity does not prevent the use of graphite as neutron converter.

  1. Design of the 50 kW neutron converter for SPIRAL2 facility

    International Nuclear Information System (INIS)

    Avilov, M.S.; Tecchio, L.B.; Titov, A.T.; Tsybulya, V.S.; Zhmurikov, E.I.

    2010-01-01

    SPIRAL2 is a facility for the study of fundamental nuclear physics and multidisciplinary research. SPIRAL2 represents a major advance for research on exotic nuclei. The radioactive ion beam (RIB) production system is comprised of a neutron converter, a target and an ion source. This paper is dedicated to the designing of the 50 kW neutron converter for the SPIRAL2 facility. Among the different variants of the neutron converter, the one based on a rotating solid disk seems quite attractive due to its safety, ease in production and relatively low cost. Dense graphite used as the converter's material allows the production of high-intensity neutron flux and, at the same time, the heat removal from the converter by means of radiation cooling. Thermo-mechanical simulations performed in order to determine the basic geometry and physical characteristics of the neutron production target for SPIRAL2 facility, to define the appropriate beam power distribution, and to predict the target behaviour under the deuteron beam of nominal parameters (40 MeV, 1.2 mA, 50 kW) are presented. To study the main physical and mechanical properties and serviceability under operating conditions, several kinds of graphite have been analyzed and tested. The paper reports the results of such measurements. Radiation damage is the most important issue for the application of graphite as neutron converter. It is well known that the thermal conductivity of the neutron-irradiated graphite is reduced by a factor of 10 from the initial value after irradiation. Difference in volume expansions between the matrix and the fiber results in serious damage of neutron-irradiated C/C composites. Calculations showed that at high temperature the effect of neutron radiation is not so critical and that the change in thermal conductivity does not prevent the use of graphite as neutron converter.

  2. Wind/solar resource in Texas

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, V.; Starcher, K.; Gaines, H. [West Texas A& M Univ., Canyon, TX (United States)

    1997-12-31

    Data are being collected at 17 sites to delineate a baseline for the wind and solar resource across Texas. Wind data are being collected at 10, 25, and 40 m (in some cases at 50 m) to determine wind shear and power at hub heights of large turbines. Many of the sites are located in areas of predicted terrain enhancement. The typical day in a month for power and wind turbine output was calculated for selected sites and combination of sites; distributed systems. Major result to date is that there is the possibility of load matching in South Texas during the summer months, even though the average values by month indicate a low wind potential.

  3. Wind energy potential in Peshawar, Pakistan

    International Nuclear Information System (INIS)

    Nasir, S.M.; Raza, S.M.

    1994-01-01

    Hourly wind data at Peshawar airport, received from the Headquarters, Pakistan Air Force, has been used to determine the diurnal variations, speed duration and speed frequency curves. The applicability of Weibull distribution is then tested over probability density function, which shows that weibull distribution fits the wind data satisfactorily and with a good precision, provided the observations of calm spells are omitted. Our analysis shows that monthly mean wind speed and wind power varies from 0.6 to 2.0 m/s and 0.2 to 4.0 wm-2, respectively, giving fair prospects for wind owe applications over the summer months. (author)

  4. Dynamic behaviour studies of a vertical axis wind turbine blade using Operational Modal Analysis (OMA) and Experimental Modal Analysis (EMA)

    DEFF Research Database (Denmark)

    Najafi, Nadia; Schmidt Paulsen, Uwe; Belloni, F.

    2014-01-01

    Dynamic behavior of a modified blade fitted onto a small 1 kW vertical-axis wind turbine is studied by two different approaches: Classical modal analysis (EMA) is carried out to validate the results of Operational Modal Analysis (OMA). In traditional modal analysis (EMA) one axis accelerometers...... it is excited by random and wind forces. The cameras are programmed in LabView to take pictures at the same time with 180 fps and store them on a high speed hard disk. The output deflection will be investigated in frequency domain by peak picking method, and then AR (Autoregressive) model is applied to describe...

  5. FY 1998 Report on development of large-scale wind power generation systems. Feasibility study on development of new technologies for wind power generation (Study on the development of wind power generation systems for small-scale power grids); 1998 nendo ogata furyoku hatsuden system kaihatsu seika hokokusho. Furyoku hatsuden shingijutsu kaihatsu kanosei chosa (shokibo keito ni okeru furyoku hatsuden system ni kansuru chosa)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This survey includes the characteristics of small-scale power grids, feasibility studies on introduction of wind turbines in these grids, and statuses of application of wind turbines to isolated islands or the like in the advanced countries, in order to promote introduction of wind power generation systems in isolated islands or the like. It is concluded that small-capacity wind power generation systems can be possibly introduced in the intermediate- to large-scale grids in isolated islands, 1,500kW or larger in capacity, in the Tokyo, Kyushu and Okinawa Electric Power Companies' areas. A scheduled steamer ship for isolated islands can carry up to 10 ton track, and introduction of a small-scale wind turbine is more advantageous viewed from the transportation cost. Some foreign countries have the sites which have achieved a high percentage of grid connection of wind power units by stabilizing wind conditions and connecting them to the main high-voltage grids in different manners from those adopted in Japan. For developing wind turbine bodies, most of the foreign countries surveyed are concentrating their efforts on development and manufacture of large-size units, paying little attention on development of small-size wind turbines for isolated islands. For the future prospects, the promising concepts include adoption of wind turbines small in capacity and easy to transport and assemble, and hybrid systems combined with power storage units. (NEDO)

  6. Final report on 9 kW Stirling Engine for biogas and natural gas

    DEFF Research Database (Denmark)

    Carlsen, Henrik; Bovin, Jonas Kabell

    2001-01-01

    The need for a simple and robust engine for natural gas and low quality gas has resulted in the design of a single cylinder, hermetic Stirling engine, which has an electric power output of 9 kW. Two engines have been built. One engine is intended for natural gas as fuel and the other is intended...... eliminates guiding forces on the pistons and the need for X-heads. Grease lubricated needle and ball bearings are used in the kinematic crank mechanism in order to avoid oil penetrating into the cylinder volumes. Working gas is Helium at 8 MPa mean pressure. The engine produce up to 11 kW of shaft power...... corresponding to approximately 10 kW of electric power. The design target was an efficiency of 26 % based on lower heat content of the gas to electricity, but only 24% were obtained. The decrease of efficiency is caused by inhomogeneous capacity flows in the air preheater and insufficient insulation...

  7. 30-kW SEP Spacecraft as Secondary Payloads for Low-Cost Deep Space Science Missions

    Science.gov (United States)

    Brophy, John R.; Larson, Tim

    2013-01-01

    The Solar Array System contracts awarded by NASA's Space Technology Mission Directorate are developing solar arrays in the 30 kW to 50 kW power range (beginning of life at 1 AU) that have significantly higher specific powers (W/kg) and much smaller stowed volumes than conventional rigid-panel arrays. The successful development of these solar array technologies has the potential to enable new types of solar electric propulsion (SEP) vehicles and missions. This paper describes a 30-kW electric propulsion vehicle built into an EELV Secondary Payload Adapter (ESPA) ring. The system uses an ESPA ring as the primary structure and packages two 15-kW Megaflex solar array wings, two 14-kW Hall thrusters, a hydrazine Reaction Control Subsystem (RCS), 220 kg of xenon, 26 kg of hydrazine, and an avionics module that contains all of the rest of the spacecraft bus functions and the instrument suite. Direct-drive is used to maximize the propulsion subsystem efficiency and minimize the resulting waste heat and required radiator area. This is critical for packaging a high-power spacecraft into a very small volume. The fully-margined system dry mass would be approximately 1120 kg. This is not a small dry mass for a Discovery-class spacecraft, for example, the Dawn spacecraft dry mass was only about 750 kg. But the Dawn electric propulsion subsystem could process a maximum input power of 2.5 kW, and this spacecraft would process 28 kW, an increase of more than a factor of ten. With direct-drive the specific impulse would be limited to about 2,000 s assuming a nominal solar array output voltage of 300 V. The resulting spacecraft would have a beginning of life acceleration that is more than an order of magnitude greater than the Dawn spacecraft. Since the spacecraft would be built into an ESPA ring it could be launched as a secondary payload to a geosynchronous transfer orbit significantly reducing the launch costs for a planetary spacecraft. The SEP system would perform the escape

  8. Active vibration-based SHM system: demonstration on an operating Vestas V27 wind turbine

    DEFF Research Database (Denmark)

    Tcherniak, Dmitri; Mølgaard, Lasse Lohilahti

    2016-01-01

    with the system and a 3.5 month monitoring campaign was conducted while the turbine was operating normally. During the campaign, a defect – a trailing edge opening – was artificially introduced into the blade and its size was gradually increased from the original 15 cm to 45 cm. Using an unsupervised learning......This study presents a system that is able to detect defects like cracks, leading/trailing edge opening or delamination of at least 15 cm size, remotely, without stopping the wind turbine. The system is vibration-based: mechanical energy is artificially introduced by means of an electromechanical......-to-noise ratio. At the same time, the corresponding wavelength is short enough to deliver required damage detection resolution and long enough to be able to propagate the entire blade length. The paper demonstrates the system on a 225 kW Vesta s V27 wind turbine. One blade of the wind turbine was equipped...

  9. Rooftop wind resource assessment using a three-dimensional ultrasonic anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.C.; Whale, J.; Livingston, P.O.; Chan, D. [Murdoch Univ., Murdoch, WA (Australia)

    2008-07-01

    Building integrated wind turbines (BUWTs) are designed for the built environment and can be located on or next to buildings. In general, these types of urban wind turbines are less than 20 kW in rated capacity, and have the potential to contribute to the energy needs of the building and reduce overall emissions. There are currently over 32 manufacturers and 57 different urban wind turbine products available in Europe alone. The first rooftop wind system in Australia was installed in 2006. To data, 5 systems have been installed and there are plans for up to 20 more. The main problems associated with these types of systems are due to poor wind resources at the location or improper site selection for the turbine. This paper reported on a research study into initiating best practice guidelines for rooftop wind systems. There is a concern that environmentally conscious homeowners or businesses will install rooftop wind systems in support of sustainability, but without adequate consideration of safety, structural building integrity or turbine performance. The potential consequence of such projects could be the failure of the project due to underperforming turbines, noise, and vibration; or the development of a negative reputation for wind energy and the renewable energy industry. This study included 2 primary initiatives, notably a computer simulated modeling exercise and an onsite rooftop wind monitoring station. This paper focused on the methodology and justification for developing the monitoring station. An ultrasonic 3D anemometer was used to collect data and to develop a 3D wind profile. The wind regime on the rooftop in the complex terrain of the built environment was highly dynamic, turbulent, and included a strong vertical component. It was concluded that site selection for turbines must be determined by a proper feasibility study involving accurate data. Although the initial phase of the project to predict the resource and deploy the monitoring station has been

  10. A Novel Wind Speed Forecasting Model for Wind Farms of Northwest China

    Science.gov (United States)

    Wang, Jian-Zhou; Wang, Yun

    2017-01-01

    Wind resources are becoming increasingly significant due to their clean and renewable characteristics, and the integration of wind power into existing electricity systems is imminent. To maintain a stable power supply system that takes into account the stochastic nature of wind speed, accurate wind speed forecasting is pivotal. However, no single model can be applied to all cases. Recent studies show that wind speed forecasting errors are approximately 25% to 40% in Chinese wind farms. Presently, hybrid wind speed forecasting models are widely used and have been verified to perform better than conventional single forecasting models, not only in short-term wind speed forecasting but also in long-term forecasting. In this paper, a hybrid forecasting model is developed, the Similar Coefficient Sum (SCS) and Hermite Interpolation are exploited to process the original wind speed data, and the SVM model whose parameters are tuned by an artificial intelligence model is built to make forecast. The results of case studies show that the MAPE value of the hybrid model varies from 22.96% to 28.87 %, and the MAE value varies from 0.47 m/s to 1.30 m/s. Generally, Sign test, Wilcoxon's Signed-Rank test, and Morgan-Granger-Newbold test tell us that the proposed model is different from the compared models.

  11. Product and corporate carbon footprint using the compound method based on financial accounts. The case of Osorio wind farms

    International Nuclear Information System (INIS)

    Alvarez, Sergio; Sosa, María; Rubio, Agustín

    2015-01-01

    Highlights: • We applied novel organisation-product-based-life-cycle assessment to Osorio Wind Farms. • This study includes sources, phases and areas previously unreported for the wind power sector. • MC3 assess carbon footprint in a practical and comprehensive manner. • MC3 is suitable for its application in major international projects. - Abstract: The challenge of developing clean and renewable energy sources is becoming ever more urgent. Over the last decade, the concept of carbon footprint has been used to report direct and indirect greenhouse gas emissions and as a support for sustainable consumption decisions. However, the discrepancies in the approaches based on either the product or corporate carbon footprint can seriously hinder its successful implementation. The so-called compound method based on financial accounts is a tiered hybrid method which enables the calculation of both the product and corporate carbon footprint. This work aims to assess this method as a tool for carbon footprint through its implementation in a comprehensive life-cycle assessment of the Osorio Wind Farms in Brazil. The total cumulative life-cycle emissions are 362.455 t CO 2 eq, representing 18.33 gr CO 2 eq per kW h delivered to the Brazilian national power grid. The difference with regard to previous works derives from its broader scope and different assumptions. In this study the comparable value from wind turbine manufacture, transport and construction is 8.42 gr CO 2 eq per kW h, 56% lower than the mean figure reported by Arvesen and Hertwich (2012). This study includes sources, phases and areas previously unreported in the carbon footprint reviews for the wind power sector. We conclude that the compound method based on financial accounts is a practical method that allows the definition of a more comprehensive goal and scope. Its implementation at Osorio Wind Farms demonstrates the method’s suitability for application in major international projects and

  12. Evaluation of urethane for feasibility of use in wind turbine blade design

    Science.gov (United States)

    Lieblein, S.; Ross, R. S.; Fertis, D. G.

    1979-01-01

    A preliminary evaluation was conducted of the use of cast urethane as a possible material for low-cost blades for wind turbines. Specimen test data are presented for ultimate tensile strength, elastic modulus, flexural strain, creep, and fatigue properties of a number of urethane formulations. Data are also included for a large-scale urethane blade section composed of cast symmetrical half-profiles tested as a cantilever beam. Based on these results, an analysis was conducted of a full-scale blade design of cast urethane that meets the design specifications of the rotor blades for the NASA/DOE experimental 100-kW MOD-0 wind turbine. Because of the low value of elastic modulus for urethane (around 457 000 psi), the design loads would have to be carried by metal reinforcement. Considerations for further evaluation are noted.

  13. Characterisation of 100 kW electron beam melting gun and its adaptation as electron gun for high power DC electron accelerators

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Waghmare, Abhay; Tiwari, Rajnish; Bakhtsingh, R.I.; Dasgupta, K.; Gupta, Sachin; Prakash, Baibhaw; Jha, M.N.

    2015-01-01

    The paper deals with the characterization of the 100 kW electron beam melting gun for its adaptation in high power DC Electron Accelerators. The indigenously designed electron beam melting system at BARC is chosen for characterization. It comprises of electron gun as source of electrons, two electromagnetic focusing lenses viz. upper focusing lens and lower focusing lens for beam focusing, intermediate beam aperture for vacuum decoupling between gun region and melt zone, deflection and oscillation lens for maneuvering the beam on the melt charge and water cooled crucible that acts as a beam dump. In this system, the electron gun is designed for 40 kV and 100 kW corresponding to a maximum beam current of 2.5 A. The electron gun uses directly heated spiral tungsten filament. The operating temperature of the filament is 2800 °K. The focusing electrode and the anode profile are designed based on Pierce geometry. High Power DC Electron Accelerators require high currents of 1 A. The beam must comply with the requirement of 40 mm beam diameter and 10 mrad divergence at the exit of the electron gun. The characterization of the existing electron gun was done to find out all the beam parameters, for e.g. beam size, beam divergence, perveance etc. to be adapted or to be modified for the design of electron gun for high power DC accelerators. This paper shows limitations and the possible solutions for design of high power DC accelerators. (author)

  14. On wind speed pattern and energy potential in Nigeria

    International Nuclear Information System (INIS)

    Adaramola, M.S.; Oyewola, O.M.

    2011-01-01

    The aim of this paper is to review wind speed distribution and wind energy availability in Nigeria and discuss the potential of using this resource for generation of wind power in the country. The power output from a wind turbine is strongly dependent on the wind speed and accurate information about the wind data in a targeted location is essential. The annual mean wind speeds in Nigeria range from about 2 to 9.5 m/s and the annual power density range between 3.40 and 520 kW/m 2 based on recent reported data. The trend shows that wind speeds are low in the south and gradually increases to relatively high speeds in the north. The areas that are suitable for exploitation of wind energy for electricity generation as well as for water pumping were identified. Also some of the challenges facing the development of wind energy and suggested solutions were presented. - Research Highlights: → Review of wind speed distribution and wind energy availability in Nigeria in presented. → The annual mean wind speeds in Nigeria range from about 2 to 9.5 m/s and the annual power density range between 3.40 and 520 kW/m 2 based on recent reported data. → The areas that are suitable for exploitation of wind energy for electricity generation as well as for water pumping were identified.

  15. Prospects of solar photovoltaic–micro-wind based hybrid power systems in western Himalayan state of Himachal Pradesh in India

    International Nuclear Information System (INIS)

    Sinha, Sunanda; Chandel, S.S.

    2015-01-01

    Highlights: • Good prospects of PV–wind hybrid systems are found in western Himalayan Indian state. • A 6 kWp roof mounted PV–micro wind hybrid system at Hamirpur location is studied. • Optimum PV–wind hybrid system configurations are determined for 12 locations in the region. • Comparative analysis of hybrid systems is carried out using ANN, NASA and measured data. • Methodology can be used for assessing the potential of hybrid power systems worldwide. - Abstract: The western Himalayan state of Himachal Pradesh is known as the hydro-power state of India with associated social and environmental problems of large hydro power plants. The reduced water inflow in the rivers during extreme winters affects power generation in the state. Therefore solar and wind resources need to be utilized to supplement power generation requirements. With this objective the prospects of photovoltaic–micro wind based hybrid systems are studied for 12 locations of the state. The NASA data, Artificial Neural Network predicted and ground measured data are used in the analysis of Hamirpur location whereas for remaining 11 locations estimated, NASA and Artificial Neural Network predicted data are used, as measured solar and wind data are not available for most of the locations in the state. Root Mean Square Error between three input data types are found to range from 0.08 to 1.89. The results show that ANN predicted data are close to measured/estimated data. A 6 kWp roof mounted photovoltaic–micro wind hybrid system at Hamirpur with daily average energy demand of 5.2 kWh/day is studied. This system specifications are used to obtain optimum PV–micro wind based hybrid power system configurations for all locations. The optimum configuration for Hamirpur is found to be a 5 kWp micro wind turbine, 2 kW converter, 10 batteries and 8 kWp PV system whereas for other 11 locations a 5 kWp micro wind turbine, 2 kW converter, 10 batteries and 2–9 kWp PV systems are obtained. The

  16. Analyzing the requirements for mass production of small wind turbine generators

    Science.gov (United States)

    Anuskiewicz, T.; Asmussen, J.; Frankenfield, O.

    Mass producibility of small wind turbine generators to give manufacturers design and cost data for profitable production operations is discussed. A 15 kW wind turbine generator for production in annual volumes from 1,000 to 50,000 units is discussed. Methodology to cost the systems effectively is explained. The process estimate sequence followed is outlined with emphasis on the process estimate sheets compiled for each component and subsystem. These data enabled analysts to develop cost breakdown profiles crucial in manufacturing decision-making. The appraisal also led to various design recommendations including replacement of aluminum towers with cost effective carbon steel towers. Extensive cost information is supplied in tables covering subassemblies, capital requirements, and levelized energy costs. The physical layout of the plant is depicted to guide manufacturers in taking advantage of the growing business opportunity now offered in conjunction with the national need for energy development.

  17. A 50-kW Module Power Station of Directly Solar-Pumped Iodine Laser

    Science.gov (United States)

    Choi, S. H.; Lee, J. H.; Meador, W. E.; Conway, E. J.

    1997-01-01

    The conceptual design of a 50 kW Directly Solar-Pumped Iodine Laser (DSPIL) module was developed for a space-based power station which transmits its coherent-beam power to users such as the moon, Martian rovers, or other satellites with large (greater than 25 kW) electric power requirements. Integration of multiple modules would provide an amount of power that exceeds the power of a single module by combining and directing the coherent beams to the user's receiver. The model developed for the DSPIL system conservatively predicts the laser output power (50 kW) that appears much less than the laser output (93 kW) obtained from the gain volume ratio extrapolation of experimental data. The difference in laser outputs may be attributed to reflector configurations adopted in both design and experiment. Even though the photon absorption by multiple reflections in experimental cavity setup was more efficient, the maximum secondary absorption amounts to be only 24.7 percent of the primary. However, the gain volume ratio shows 86 percent more power output than theoretical estimation that is roughly 60 percent more than the contribution by the secondary absorption. Such a difference indicates that the theoretical model adopted in the study underestimates the overall performance of the DSPIL. This fact may tolerate more flexible and radical selection of design parameters than used in this design study. The design achieves an overall specific power of approximately 5 W/kg and total mass of 10 metric tons.

  18. 200 kW, 800 MHz transmitter system for lower hybrid heating

    International Nuclear Information System (INIS)

    Deitz, A.

    1975-01-01

    This paper describes a new rf heating system which has just been completed and is now operational on the ATC machine. The system utilizes four UHF TV klystrons to generate at least 200 kW of power at a frequency of 800 MHz. Pulse widths can be varied from 20 μsec up to 20 msec. A radar type floating deck modulator along with photo-optical transmitting and receiving devices have been incorporated into the system to provide the pulse fidelity and versatility which characterizes this equipment. Modular construction was emphasized in the design, when possible, to reduce maintenance and down time in the advent of component falilure. Hybrid combining techniques are utilized in order to provide two 100 kW feeds into the machine

  19. Application of aeroacoustic models to design of wind turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Fuglsang, P.; Madsen, H.A. [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1997-12-31

    A design method is presented for wind turbine rotors. The design process is split into overall design of the rotor and detailed design of the blade tip. A numerical optimization tool is used together with a semi-empirical noise prediction code for overall rotor design. The noise prediction code is validated with measurements and good agreement is obtained both on the total noise emission and on the sensitivity to wind speed, tip pitch angle and tip speed. A design study for minimum noise emission for a 300 kW rotor shows that the total sound power level can be reduced by 3 dB(A) without loss in energy production and the energy production can be increased by 2% without increase in the total noise. Detailed CFD calculations are subsequently done to resolve the blade tip flow. The characteristics of the general flow and the tip vortex are found, and the relevant parameters for the aeroacoustic models are derived for a sharp rectangular tip. (au) 16 refs.

  20. Summary of tower designs for large horizontal axis wind turbines

    Science.gov (United States)

    Frederick, G. R.; Savino, J. M.

    1986-01-01

    Towers for large horizontal axis wind turbines, machines with a rotor axis height above 30 meters and rated at more than 500 kW, have varied in configuration, materials of construction, type of construction, height, and stiffness. For example, the U.S. large HAWTs have utilized steel truss type towers and free-standing steel cylindrical towers. In Europe, the trend has been to use only free-standing and guyed cylindrical towers, but both steel and reinforced concrete have been used as materials of construction. These variations in materials of construction and type of construction reflect different engineering approaches to the design of cost effective towers for large HAWTs. Tower designs are the NASA/DOE Mod-5B presently being fabricated. Design goals and requirements that influence tower configuration, height and materials are discussed. In particular, experiences with United States large wind turbine towers are elucidated. Finally, current trends in tower designs for large HAWTs are highlighted.

  1. Perspectives of the wind power in the world

    International Nuclear Information System (INIS)

    Juanico, Luis

    2005-01-01

    The world market of wind generation is absolutely minority (less 1%) and is concentrated on few countries developed.It is found prompted by medium-environmental interests and protected by important politics of incentives, of which depends hardly to subsist.These factors have permitted him to grow up to a point.The framework of subsidies and incentives that favors it also is seen threatened.At present the European Union is found immersed in a process of full energy integration, eliminating all the present subsidies.The present technology of wind turbines presents an evolutionary technological line, which does not permit new economies of scale by increase of size of the turbines and is not competitive.The costs of capital of a wind farm is about 1200 $/kW, the operating costs 1,5 cU$/Kwh and the average load factor in the world is the 23%.In extensive regions of the Third World the zones with greater Aeolian potential are found, being privileged among these the Patagonia, with Aeolian powers until 500% over the European average.But this potential, that can take advantage of only marginally in the modern wind turbines, is contrasted with the unfavorable conditions (by being a source of intensive capital, their economy is seen affected directly by the high rates of discount) that apply in the developing countries.For all the previous thing, the future of the wind power is found tied more well al general framework of the energy policies and public opinion, among others external factors, before that to endogenous factors such as its technological evolution and of real economic competitiveness

  2. Mathematical programming models for the economic design and assessment of wind energy conversion systems

    Science.gov (United States)

    Reinert, K. A.

    The use of linear decision rules (LDR) and chance constrained programming (CCP) to optimize the performance of wind energy conversion clusters coupled to storage systems is described. Storage is modelled by LDR and output by CCP. The linear allocation rule and linear release rule prescribe the size and optimize a storage facility with a bypass. Chance constraints are introduced to explicitly treat reliability in terms of an appropriate value from an inverse cumulative distribution function. Details of deterministic programming structure and a sample problem involving a 500 kW and a 1.5 MW WECS are provided, considering an installed cost of $1/kW. Four demand patterns and three levels of reliability are analyzed for optimizing the generator choice and the storage configuration for base load and peak operating conditions. Deficiencies in ability to predict reliability and to account for serial correlations are noted in the model, which is concluded useful for narrowing WECS design options.

  3. Noise annoyances from wind power: Survey of the population living close to a wind power plant. Final report: Part 3 Main study; Stoerningar fraan vindkraft: undersoekning bland maenniskor boende i naerheten av vindkraftverk. Slutrapport: Del 3 Huvudstudie

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Eja [Halmstad Univ., Halmstad (Sweden). School of Business and Engineering; Persson-Waye, K. [Goeteborg Univ., Goeteborg (Sweden). Dept. of Environmental Medicine

    2002-02-01

    To evaluate the occurrence of annoyance from wind turbines, a study was performed in Laholm in May 2000. The aim was to obtain dose response relationships between calculated sound levels and noise annoyance and appropriate sound description as well as analysing the influence of other variables on noise annoyance. A questionnaire survey was performed in 6 areas comprising 16 wind turbines, of which 14 had an effect of 600 kW. The purpose of the study was masked. Among questions on living conditions in the countryside, questions directly related to wind turbines were included. The study population (n=518) comprised one randomly selected subject between the ages of 18 to 75 years in each household living within a calculated wind turbine sound level of 25 to 40 dBA. The response rate was 68.7% (n=356). Calculated distributions of A-weighted sound level were performed for each area and plotted on geographical maps in 2.5 dBA steps. Each dwelling could thus be given a sound level within an interval of 2.5 dBA. The most frequently occurring source of noise annoyance was noise from rotor blades. The proportions of respondents annoyed by noise increased with calculated sound level. Among respondents exposed to sound levels of 35.0-37.5 dBA, 43% responded themselves to be rather or much annoyed. A-weighted sound level was only one variable explaining annoyance. Annoyance was correlated to a larger extent by the intrusiveness of the sound character swishing. Noise annoyance was interrelated to the respondents' opinion of the visual impact of wind turbines, while attitude towards wind power in general had no greater influence. Disturbance of spoilt view was reported to a similar degree as noise disturbance. Further investigations are needed to clarify factors of importance for the disturbance of view. All the wind turbines in the study had constant rotation speed. The greater wind turbines that are now erected often have variable speed, which may lead to a sound

  4. Performance improvement of 100 kW high frequency transmitter for CW operation

    International Nuclear Information System (INIS)

    Kwak, J. G.; Yoon, J. S.; Bae, Y. D.; Cho, C. G.; Wang, S. J.; Lee, K. D.

    2001-08-01

    For the plasma heating of KSTAR(Korea Superconducting Tokamak Advanced Research)by using ICH(Ion Cyclotron Heating), it is designed that the selective ion heating and current drive are performed by the transmitter with the rf power of 8 MW in the frequency range of 25-60 MHz. 100 kW HF transmitter was constructed for the high voltage/current test of ICH antenna and HF transmission components. The output power is about 100 kW around 30 MHz. Thomson 581 tetrode is used for the final amplifier whose cavity type is ground cathode. Overall gain is above 15 dB and the bandwidth is about 100 kHz

  5. Test result of 5 GHz, 500 kW CW prototype klystron for KSTAR LHCD system

    Energy Technology Data Exchange (ETDEWEB)

    Do, H., E-mail: heejindo@nfri.re.kr [Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Park, S. [Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Jeong, J.H.; Bae, Y.S.; Yang, H.L. [National Fusion Research Institute, Daejeon 350-333 (Korea, Republic of); Delpech, L.; Magne, R.; Hoang, G.T. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Park, H.; Cho, M.H.; Namkung, W. [Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2011-10-15

    A 5 GHz LHCD system is being designed for current drive and profile modification necessary for AT mode and steady-state operation of the KSTAR tokamak. A prototype 500 kW CW klystron operating at 5 GHz was developed for the steady-state RF source. In this klystron, a multi-cell cavity is introduced to reduce cavity voltage and ohmic power loss. The klystron is designed with a triode system for optimization of gain, efficiency and beam control. The high voltage for the cathode is turned by using a thyristor switching system at the low voltage transformer unit. For anode voltage control, a mod-anode voltage divider system is used which utilize the parallel-circuit of the FET switch and Zener diodes. The RF output power of the klystron was 300 kW for 800 s and 450 kW for 20 s. The maximal temperature at collector top surface was 83 deg. C and power loss at the tube body did not exceed 10 kW, the interlock level for the protection of the klystron. Detailed results of the klystron system test and commissioning are presented.

  6. Harmonic analysis and suppression in hybrid wind & PV solar system

    Science.gov (United States)

    Gupta, Tripti; Namekar, Swapnil

    2018-04-01

    The growing demand of electricity has led to produce power through non-conventional source of energy such as solar energy, wind energy, hydro power, energy through biogas and biomass etc. Hybrid system is taken to complement the shortcoming of either sources of energy. The proposed system is grid connected hybrid wind and solar system. A 2.1 MW Doubly fed Induction Generator (DFIG) has been taken for analysis of wind farm whose rotor part is connected to two back-to-back converters. A 250 KW Photovoltaic (PV) array taken to analyze solar farm where inverter is required to convert power from DC to AC since electricity generated through solar PV is in the form of DC. Stability and reliability of the system is very important when the system is grid connected. Harmonics is the major Power quality issue which degrades the quality of power at load side. Harmonics in hybrid system arise through the use of power conversion unit. The other causes of harmonics are fluctuation in wind speed and solar irradiance. The power delivered to grid must be free from harmonics and within the limits specified by Indian grid codes. In proposed work, harmonic analysis of the hybrid system is performed in Electrical Transient Analysis program (ETAP) and single tuned harmonic filter is designed to maintain the utility grid harmonics within limits.

  7. Wind-Electric Power Potential Assessment for Three Locations in East Java-Indonesia

    Directory of Open Access Journals (Sweden)

    Ali Musyafa

    2011-08-01

    Full Text Available This paper reports our effort to asses wind energy potentials for three locations in East Java. We used wind speed data over a period of almost 3 years, i.e. in period of June 2006 – August 2008. Data were taken from direct measurement in locations in East Java Province, i.e. Sampang (Madura, Juanda (Surabaya, and Sawahan (Nganjuk. The short-term of wind speed mean in monthly signifies to wind-speed value ”which parallels to the wind turbine power curve value” were used to estimate the annual energy output for a 1 MW installed capacity wind farm on the each site 100 of 10kW rated wind turbines were used in the analysis. The short term of wind speed mean at Surabaya and Nganjuk were 2.34, 3.03 and 1.97 m/s at 2 m Above Ground Level (AGL, respectively. In both locations, wind speeds were observed during the day time between 04.00 and 18.00 and relatively smaller ones between 19.00 and 03.00 period. Meanwhile, in Sampang (Madura the higher wind speeds were observed between 20.00 and 06.00, and relatively smaller between 07.00 and 19.00 period. The 1 MW windfarm at Sampang, Surabaya and Nganjuk can produce 1.284; 1.199 and 1.008 MWh of electricity yearly, taking into consideration of the temperature adjustment coefficien of about 6 %. The plant capacity factor at Sampang, Surabaya and Nganjuk were found to be 30.02 %, 30.00 % and 30.01 % respectively. Additionally, it is noticed that these site can contribute to the avoidance of 0.904; 0.846 and 0.709 tons/year of CO2 equivalent Green House Gases (GHG from entering into the local atmosphere, thus creating a clean and healthy athmosphere for local inhabitants.

  8. Global empirical wind model for the upper mesosphere/lower thermosphere. I. Prevailing wind

    Directory of Open Access Journals (Sweden)

    Y. I. Portnyagin

    Full Text Available An updated empirical climatic zonally averaged prevailing wind model for the upper mesosphere/lower thermosphere (70-110 km, extending from 80°N to 80°S is presented. The model is constructed from the fitting of monthly mean winds from meteor radar and MF radar measurements at more than 40 stations, well distributed over the globe. The height-latitude contour plots of monthly mean zonal and meridional winds for all months of the year, and of annual mean wind, amplitudes and phases of annual and semiannual harmonics of wind variations are analyzed to reveal the main features of the seasonal variation of the global wind structures in the Northern and Southern Hemispheres. Some results of comparison between the ground-based wind models and the space-based models are presented. It is shown that, with the exception of annual mean systematic bias between the zonal winds provided by the ground-based and space-based models, a good agreement between the models is observed. The possible origin of this bias is discussed.

    Key words: Meteorology and Atmospheric dynamics (general circulation; middle atmosphere dynamics; thermospheric dynamics

  9. Experimental and Numerical Vibrational Analysis of a Horizontal-Axis Micro-Wind Turbine

    Directory of Open Access Journals (Sweden)

    Francesco Castellani

    2018-02-01

    Full Text Available Micro-wind turbines are energy conversion technologies strongly affected by fatigue, as a result of their size and the variability of loads, induced by the unsteady wind conditions, and modulated by a very high rotational speed. This work is devoted to the experimental and numerical characterization of the aeroelastic behavior of a test-case horizontal-axis wind turbine (HAWT with a 2 m rotor diameter and a maximum power production of 3 kW. The experimental studies have been conducted at the wind tunnel of the University of Perugia and consisted of accelerometer measurements at the tower and the tail fin. The numerical setup was the Fatigue, Aerodynamics, Structures, and Turbulence (FAST code for aeroelastic simulations, which was fed as input with the same wind conditions employed in the wind tunnel tests. The experimental and numerical analyses were coupled with the perspective of establishing a reciprocal feedback, and this has been accomplished. On one hand, the numerical model is important for interpreting the measured spectrum of tower oscillations and, for example, inspires the detection of a mass unbalance at the blades. On the other hand, the measurements inspire the question of how to interpret the interaction between the blades and the tower. The experimental spectrum of tail fin vibrations indicates that secondary elements, in terms of weight, can also transmit to the tower, giving meaningful contributions to the vibration spectra. Therefore, an integrated numerical and experimental approach is not only valuable but is also unavoidable, to fully characterize the dynamics of small wind-energy conversion systems.

  10. Development and test of an axial flux type PM synchronous motor with liquid nitrogen cooled HTS armature windings

    International Nuclear Information System (INIS)

    Sugimoto, H; Morishita, T; Tsuda, T; Takeda, T; Togawa, H; Oota, T; Ohmatsu, K; Yoshida, S

    2008-01-01

    We developed an axial gap permanent magnet type superconducting synchronous motor cooled by liquid nitrogen (LN 2 ). The motor includes 8 poles and 6 armature windings. The armature windings are made from BSCCO wire operated at the temperature level between 66K∼70K. The design of the rated output is 400kW at 250rpm. Because HTS wires produce AC loss, there are few motors developed with a superconducting armature winding. In a large capacity motor, HTS windings need to be connected in parallel way. However, the parallel connection causes different current flowing to each HTS winding. To solve this problem, we connected a current distributor to the motor. As a result, not only the current difference can be suppressed, but also the current of each winding can be adjusted freely. The low frequency and less flux penetrating HTS wire because of current distributor contribute to low AC loss. This motor is an axial gap rotating-field one, the cooling parts are fixed. This directly leads to simple cooling system. The motor is also brushless. This paper presents the structure, the analysis of the motor and the tests

  11. Wind Speed Perception and Risk

    Science.gov (United States)

    Agdas, Duzgun; Webster, Gregory D.; Masters, Forrest J.

    2012-01-01

    Background How accurately do people perceive extreme wind speeds and how does that perception affect the perceived risk? Prior research on human–wind interaction has focused on comfort levels in urban settings or knock-down thresholds. No systematic experimental research has attempted to assess people's ability to estimate extreme wind speeds and perceptions of their associated risks. Method We exposed 76 people to 10, 20, 30, 40, 50, and 60 mph (4.5, 8.9, 13.4, 17.9, 22.3, and 26.8 m/s) winds in randomized orders and asked them to estimate wind speed and the corresponding risk they felt. Results Multilevel modeling showed that people were accurate at lower wind speeds but overestimated wind speeds at higher levels. Wind speed perceptions mediated the direct relationship between actual wind speeds and perceptions of risk (i.e., the greater the perceived wind speed, the greater the perceived risk). The number of tropical cyclones people had experienced moderated the strength of the actual–perceived wind speed relationship; consequently, mediation was stronger for people who had experienced fewer storms. Conclusion These findings provide a clearer understanding of wind and risk perception, which can aid development of public policy solutions toward communicating the severity and risks associated with natural disasters. PMID:23226230

  12. Wind speed perception and risk.

    Directory of Open Access Journals (Sweden)

    Duzgun Agdas

    Full Text Available BACKGROUND: How accurately do people perceive extreme wind speeds and how does that perception affect the perceived risk? Prior research on human-wind interaction has focused on comfort levels in urban settings or knock-down thresholds. No systematic experimental research has attempted to assess people's ability to estimate extreme wind speeds and perceptions of their associated risks. METHOD: We exposed 76 people to 10, 20, 30, 40, 50, and 60 mph (4.5, 8.9, 13.4, 17.9, 22.3, and 26.8 m/s winds in randomized orders and asked them to estimate wind speed and the corresponding risk they felt. RESULTS: Multilevel modeling showed that people were accurate at lower wind speeds but overestimated wind speeds at higher levels. Wind speed perceptions mediated the direct relationship between actual wind speeds and perceptions of risk (i.e., the greater the perceived wind speed, the greater the perceived risk. The number of tropical cyclones people had experienced moderated the strength of the actual-perceived wind speed relationship; consequently, mediation was stronger for people who had experienced fewer storms. CONCLUSION: These findings provide a clearer understanding of wind and risk perception, which can aid development of public policy solutions toward communicating the severity and risks associated with natural disasters.

  13. Wind speed perception and risk.

    Science.gov (United States)

    Agdas, Duzgun; Webster, Gregory D; Masters, Forrest J

    2012-01-01

    How accurately do people perceive extreme wind speeds and how does that perception affect the perceived risk? Prior research on human-wind interaction has focused on comfort levels in urban settings or knock-down thresholds. No systematic experimental research has attempted to assess people's ability to estimate extreme wind speeds and perceptions of their associated risks. We exposed 76 people to 10, 20, 30, 40, 50, and 60 mph (4.5, 8.9, 13.4, 17.9, 22.3, and 26.8 m/s) winds in randomized orders and asked them to estimate wind speed and the corresponding risk they felt. Multilevel modeling showed that people were accurate at lower wind speeds but overestimated wind speeds at higher levels. Wind speed perceptions mediated the direct relationship between actual wind speeds and perceptions of risk (i.e., the greater the perceived wind speed, the greater the perceived risk). The number of tropical cyclones people had experienced moderated the strength of the actual-perceived wind speed relationship; consequently, mediation was stronger for people who had experienced fewer storms. These findings provide a clearer understanding of wind and risk perception, which can aid development of public policy solutions toward communicating the severity and risks associated with natural disasters.

  14. Wind-power installation on the Guetsch in Switzerland; Windkraftanlage Guetsch, EW Ursern, Andermatt UR

    Energy Technology Data Exchange (ETDEWEB)

    Russi, M.

    2006-07-01

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) takes a look at the 800 kW wind turbine installed in 2001/2002 by the Ursern electricity utility near Andermatt, Switzerland, at a height of 2350 meters above sea level. The original prototype wind turbine contained various components from Swiss industry, such as the generator and the inverter. Because of difficulties (cracks in rotor blades, bankruptcy of the manufacturer, etc.) this installation was replaced by an Enercon 600-kW-wind turbine in 2004. Characteristic features of this turbine, such as is its adaptation for use under turbulent wind conditions at cold locations, are discussed. The results obtained in 2005 made it obvious that the utilisation of wind energy in alpine regions is possible and that the extreme conditions at this location do not significantly affect the efficient and safe operation of such an installation. Together with the presence of a meteorological station in the vicinity, optimal operating conditions prevail at this site for further research projects in connection with icing-up of turbine blades and wind energy. The report describes the installation and de-installation of the first turbine and the installation of the present one. Initial experience gained with the installation and its certification by the 'Naturemade' eco-power programme is discussed, as is future expansion at the site.

  15. Design of Buoys for Mounting Wind Turbines at Exposed Sites

    Science.gov (United States)

    Erdoğan, Beytullah; Çelıkkol, Barbaros; Swift, Robinson

    2018-04-01

    In this study, two designs for a buoy capable of supporting a 10 kW wind turbine and its tower were developed to operate at the University of New Hampshire's Center of Ocean Renewable Energy testing site located off the Isles of Shoals, New Hampshire. The buoys are to be moored by a catenary chain system. To evaluate wave response, two Froude-scaled models were constructed, tested, and compared at the Ocean Engineering wave tank at the University of New Hampshire. These buoys have been implemented and compared with wave tank measurements of the spar displacement at a reference elevation 2.44 m above the mean water level.

  16. Effect of wind turbine wakes on summer-time wind profiles in the US Great Plains

    Science.gov (United States)

    Rhodes, M. E.; Lundquist, J. K.; Aitken, M.

    2011-12-01

    Wind energy is steadily becoming a significant source of grid electricity in the United States, and the Midwestern United States provides one of the nation's richest wind resources. This study examines the effect of wind turbine wakes on the wind profile in central Iowa. Data were collected using a coherent Doppler LiDAR system located approximately 2.5 rotor diameters north of a row of modern multi-MW wind turbine generators. The prevailing wind direction was from the South allowing the LiDAR to capture wind turbine wake properties; however, a number of periods existed where the LiDAR captured undisturbed flow. The LiDAR system reliably obtained readings up to 200 m above ground level (AGL), spanning the entire rotor disk (~40 m to 120 m AGL) which far surpasses the information provided by traditional wind resource assessment instrumentation. We extract several relevant parameters from the lidar data including: horizontal wind speed, vertical velocity, horizontal turbulence intensity, wind shear, and turbulent kinetic energy (TKE). Each time period at a particular LiDAR measurement height was labeled "wake" or "undisturbed" based on the wind direction at that height. Wake and undisturbed data were averaged separately to create a time-height cross-section averaged day for each parameter. Significant differences between wake and undisturbed data emerge. During the day, wake conditions experience larger values of TKE within the altitudes of the turbine rotor disk while TKE values above the rotor disk are similar between waked and undisturbed conditions. Furthermore, the morning transition of TKE in the atmospheric boundary layer commences earlier during wake conditions than in undisturbed conditions, and the evening decay of TKE persists longer during wake conditions. Waked wind shear is consistently greater than undisturbed periods at the edges of the wind turbine rotor disk (40m & 120m AGL), but especially so during the night where wind shear values during wake

  17. Construction of a 35 GHz 100 kW gyrotron; Construcao de um girotron de 35 GHz e de 100 kW

    Energy Technology Data Exchange (ETDEWEB)

    Aso, Y; Barroso, J J; Castro, P J; Correa, R A; Ludwing, G O; Montes, A; Morgado, U T.F.; Nono, M C.A.; Rossi, J O; Silva, P R

    1989-09-01

    In this work a description of a 35 GHz 100 kW gyrocon is described which is under construction at the National Space Research Institute Plasma Laboratory. Project conceptual aspects are emphasized, specifically high current density thermionic cathodes, high time and spatial resolution intense magnetic fields generation, high-vacuum systems, techniques of ceramic-metal sealing, and high-voltage electrical modulator circuits. (author). 8 refs., 9 figs., 1 tab.

  18. An assessment of KW Basin radionuclide activity when opening SNF canisters

    International Nuclear Information System (INIS)

    Bergmann, D.W.; Mollerus, F.J.; Wray, J.L.

    1995-01-01

    N Reactor spent fuel is being stored in sealed canisters in the KW Basin. Some of the canisters contain damaged fuel elements. There is the potential for release of Cs 137, Kr 85, H3, and other fission products and transuranics (TRUs) when canisters are opened. Canister opening is required to select and transfer fuel elements to the 300 Area for examination as part of the Spent Nuclear Fuel (SNF) Characterization program. This report estimates the amount of radionuclides that can be released from Mark II spent nuclear fuel (SNF) canisters in KW Basin when canisters are opened for SNF fuel sampling as part of the SNF Characterization Program. The report also assesses the dose consequences of the releases and steps that can be taken to reduce the impacts of these releases

  19. Infrared face recognition based on LBP histogram and KW feature selection

    Science.gov (United States)

    Xie, Zhihua

    2014-07-01

    The conventional LBP-based feature as represented by the local binary pattern (LBP) histogram still has room for performance improvements. This paper focuses on the dimension reduction of LBP micro-patterns and proposes an improved infrared face recognition method based on LBP histogram representation. To extract the local robust features in infrared face images, LBP is chosen to get the composition of micro-patterns of sub-blocks. Based on statistical test theory, Kruskal-Wallis (KW) feature selection method is proposed to get the LBP patterns which are suitable for infrared face recognition. The experimental results show combination of LBP and KW features selection improves the performance of infrared face recognition, the proposed method outperforms the traditional methods based on LBP histogram, discrete cosine transform(DCT) or principal component analysis(PCA).

  20. 2008 WIND TECHNOLOGIES MARKET REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ryan H.; Bolinger, Mark; Barbose, G.; Mills, A.; Rosa, A.; Porter, K.; Fink, S.; Tegen, S.; Musial, W.; Oteri, F.; Heimiller, D.; Rberts, B.; Belyeu, K.; Stimmel, R.

    2009-07-15

    domestic wind power market, including federal and state policy drivers, transmission issues, and grid integration. Finally, the report concludes with a preview of possible near- to medium-term market developments. This version of the Annual Report updates data presented in the previous editions, while highlighting key trends and important new developments from 2008. New to this edition is an executive summary of the report and an expanded final section on near- to medium-term market development. The report concentrates on larger-scale wind applications, defined here as individual turbines or projects that exceed 50 kW in size. The U.S. wind power sector is multifaceted, however, and also includes smaller, customer-sited wind turbines used to power the needs of residences, farms, and businesses. Data on these applications are not the focus of this report, though a brief discussion on Distributed Wind Power is provided on page 4. Much of the data included in this report were compiled by Berkeley Lab, and come from a variety of sources, including the American Wind Energy Association (AWEA), the Energy Information Administration (EIA), and the Federal Energy Regulatory Commission (FERC). The Appendix provides a summary of the many data sources used in the report. Data on 2008 wind capacity additions in the United States are based on information provided by AWEA; some minor adjustments to those data may be expected. In other cases, the data shown here represent only a sample of actual wind projects installed in the United States; furthermore, the data vary in quality. As such, emphasis should be placed on overall trends, rather than on individual data points. Finally, each section of this document focuses on historical market information, with an emphasis on 2008; with the exception of the final section, the report does not seek to forecast future trends.