WorldWideScience

Sample records for kalpha rotating-anode x-ray

  1. A CCD area detector for X-ray diffraction under high pressure for rotating anode source

    Indian Academy of Sciences (India)

    Amar Sinha; Alka B Garg; V Vijayakumar; B K Godwal; S K Sikka

    2000-04-01

    Details of a two-dimensional X-ray area detector developed using a charge coupled device, a image intensifier and a fibre optic taper are given. The detector system is especially optimized for angle dispersive X-ray diffraction set up using rotating anode generator as X-ray source. The performance of this detector was tested by successfully carrying out powder X-ray diffraction measurements on various materials such as intermetallics AuIn2, AuGa2, high material Pd and low scatterer adamantane (C10H16) at ambient conditions. Its utility for quick detection of phase transitions at high pressures with diamond anvil cell is demonstrated by reproducing the known pressure induced structural transitions in RbI, KI and a new structural phase transition in AuGa2 above 10 GPa. Various softwares have also been developed to analyze data from this detector.

  2. [Research of working condition monitoring and analyzing system for rotating anode X-ray tube based on the vibration measurement].

    Science.gov (United States)

    Wu, Hao; Wang, Weidong; Yan, Yong; Zhang, Shuai; Zu, Hefei; Chen, Weibin

    2011-01-01

    A non-invasive detecting and analyzing method which used to monitor the working condition of rotating anode X-ray was proposed. Based on the NI development environment, accelerometer, 24-bit high resolution data acquisition card and personal computer were connected to construct the system for collecting the vibration signal of X-ray tube. Results demonstrate that the system could acquire and store the vibration data of X-ray tube quickly and efficiently. The characteristics of vibration, were extracted and processed, which proposed a new approach to detect the malfunction of rotating anode X-ray early and effectively.

  3. X-ray Fluorescent Fe Kalpha Lines from Stellar Photospheres

    CERN Document Server

    Drake, Jeremy J; Swartz, Douglas A

    2007-01-01

    X-ray spectra from stellar coronae are reprocessed by the underlying photosphere through scattering and photoionization events. While reprocessed X-ray spectra reaching a distant observer are at a flux level of only a few percent of that of the corona itself, characteristic lines formed by inner shell photoionization of some abundant elements can be significantly stronger. The emergent photospheric spectra are sensitive to the distance and location of the fluorescing radiation and can provide diagnostics of coronal geometry and abundance. Here we present Monte Carlo simulations of the photospheric Kalpha doublet arising from quasi-neutral Fe irradiated by a coronal X-ray source. Fluorescent line strengths have been computed as a function of the height of the radiation source, the temperature of the ionising X-ray spectrum, and the viewing angle. We also illustrate how the fluorescence efficiencies scale with the photospheric metallicity and the Fe abundance. Based on the results we make three comments: (1) fl...

  4. Design and implementation of an x-ray strain measurement capability using a rotating anode machine

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, J.A.; Rangaswamy, P.; Lujan, M. Jr.; Bourke, M.A.M.

    1998-12-31

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). Residual stresses close to the surface can improve the reliability and lifetime of parts for technological applications. X-ray diffraction plays a significant role in gaining an exact knowledge of the stresses at the surface and their depth distribution. An x-ray capability at Los Alamos is key to developing and maintaining industrial collaborations in strain effects. To achieve this goal, the authors implemented a residual strain measuring station on the rotating anode x-ray instrument at the Lujan Center. This capability has been used to investigate residual strains in heat treated automotive components, machining effects on titanium alloys, resistance welded steel joints, titanium matrix fiber reinforced composites, ceramic matrix composites, thin films, and ceramic coatings. The overall objective is to combine both x-ray and neutron diffraction measurements with numerical models (e.g., finite element calculations).

  5. Resonant Auger Destruction and Iron K-Alpha Spectra in Compact X-ray Sources

    OpenAIRE

    Liedahl, Duane A.

    2005-01-01

    We examine the effects of resonant Auger destruction in modifying the intensities and flux distributions of K-alpha spectra from iron L-shell ions. Applications include X-ray irradiated stellar winds in X-ray binaries and accretion disk atmospheres. Using detailed atomic models, we find that resonant Auger destruction is selective, in that only a subset of the emitted K-alpha lines is highly attenuated. We also show that that the local excitation conditions can have a dramatic effect on the K...

  6. K-alpha conversion efficiency measurments for x-ray scattering in inertial confinement fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Kritcher, A L; Neumayer, P; Urry, M K; Robey, H; Niemann, C; Landen, O L; Morse, E; Glenzer, S H

    2006-11-21

    The conversion efficiency of ultra short-pulse laser radiation to K-{alpha} x-rays has been measured for various chlorine-containing targets to be used as x-ray scattering probes of dense plasmas. The spectral and temporal properties of these sources will allow spectrally-resolved x-ray scattering probing with picosecond temporal resolution required for measuring the plasma conditions in inertial confinement fusion experiments. Simulations of x-ray scattering spectra from these plasmas show that fuel capsule density, capsule ablator density, and shock timing information may be inferred.

  7. X-ray bumps, iron K-alpha lines, and X-ray suppression by obscuring tori in Seyfert galaxies

    Science.gov (United States)

    Krolik, Julian H.; Madau, Piero; Zycki, Piotr T.

    1994-01-01

    We investigate the X-ray spectral properties of unobscured type 1 and obscured type 2 Seyferts as predicted by the unified Seyfert scheme. We consider the reprocessing of X-ray photons by photoelectric absorption, iron fluorescence, and Compton downscattering in the obscuring tori surrounding these active nuclei, and compute by Monte Carlo methods the reprocessed spectra as a function of the viewing angle. Depending on the optical depth and shape of the torus, and on the viewing angle, the X-ray flux can be suppressed by substantial factors when our line of sight is obscured. We show that an immediate consequence of the existence of an obscuring thick torus is the production in the spectra of type 1 Seyfert galaxies of a bump in the continuum above 10-20 keV and an Fe K-alpha line with significant equivalent width. In those type 2 Seyferts for which the hard X-ray spectrum has been substantially suppressed, the equivalent width of the Fe K-alpha line in the transmitted spectrum can be very large.

  8. K-alpha X-rays from cosmic-ray oxygen. [subrelativistic interstellar oxygen ions

    Science.gov (United States)

    Pravdo, S. H.; Boldt, E. A.

    1975-01-01

    Equilibrium charge fractions are calculated for subrelativistic cosmic-ray oxygen ions in the interstellar medium. These are used to determine the expected flux of K-alpha rays arising from atomic processes for a number of different postulated interstellar oxygen spectra. Relation of these results to the diffuse X-ray background measured at the appropriate energy (about 0.6 keV) suggests an observable broadened line feature.

  9. Discovery of Oxygen Kalpha X-ray Emission from the Rings of Saturn

    CERN Document Server

    Bhardwaj, A; Waite, J H; Gladstone, G R; Cravens, T E; Ford, P G; Bhardwaj, Anil; Elsner, Ronald F.; Cravens, Thomas E.; Ford, Peter G.

    2005-01-01

    Using the Advanced CCD Imaging Spectrometer (ACIS), the Chandra X-ray Observatory (CXO) observed the Saturnian system for one rotation of the planet (~37 ks) on 20 January, 2004, and again on 26-27 January, 2004. In this letter we report the detection of X-ray emission from the rings of Saturn. The X-ray spectrum from the rings is dominated by emission in a narrow (~130 eV wide) energy band centered on the atomic oxygen K-alpha fluorescence line at 0.53 keV. The X-ray power emitted from the rings in the 0.49-0.62 keV band is 84 MW, which is about one-third of that emitted from Saturn disk in the photon energy range 0.24-2.0 keV. Our analysis also finds a clear detection of X-ray emission from the rings in the 0.49-0.62 keV band in an earlier (14-15 April, 2003) Chandra ACIS observation of Saturn. Fluorescent scattering of solar X-rays from oxygen atoms in the H2O icy ring material is the likely source mechanism for ring X-rays, consistent with the scenario of solar photo-production of a tenuous ring oxygen at...

  10. Microlensing of the Fe K$\\alpha$ line and the X-ray continuum

    CERN Document Server

    Popovic, L C; Mediavilla, E; Zakharov, A F; Abajas, C; Muñoz, J A; Chartas, G

    2005-01-01

    The observed enhancement of the Fe K$\\alpha$ line in three gravitationally lensed QSOs (MG J0414+0534, QSO 2237+0305, H1413+117) is interpreted in terms of microlensing, even when equivalent X-ray continuum amplification is not observed. In order to interpret these observations, first we studied the effects of microlensing on quasars spectra, produced by straight fold caustic crossing over standard relativistic accretion disk. The disk emission was analyzed using the ray tracing method, considering Schwarzschild and Kerr metrics. When the emission is separated in two regions (an inner disk corresponding to the Fe K$\\alpha$ line and an outer annulus corresponding to the continuum, or vice-versa) we find microlensing events which enhance the Fe K$\\alpha$ line without noticeable amplification of the X-ray continuum, but only during a limited time interval. Continuum amplification is expected if a complete microlensing event is monitored. Second, we studied a more realistic case of amplification by caustic magnif...

  11. X-ray resonant photoexcitation: line widths and energies of K{\\alpha} transitions in highly charged Fe ions

    CERN Document Server

    Rudolph, J K; Epp, S W; Steinbrügge, R; Beilmann, C; Brown, G V; Eberle, S; Graf, A; Harman, Z; Hell, N; Leutenegger, M; Müller, A; Schlage, K; Wille, H -C; Yavas, H; Ullrich, J; López-Urrutia, J R Crespo

    2013-01-01

    Photoabsorption by and fluorescence of the K{\\alpha} transitions in highly charged iron ions are essential mechanisms for X-ray radiation transfer in astrophysical environments. We study photoabsorption due to the main K{\\alpha} transitions in highly charged iron ions from heliumlike to fluorinelike (Fe 24+...17+) using monochromatic X-rays around 6.6 keV at the PETRA III synchrotron photon source. Natural linewidths were determined with hitherto unattained accuracy. The observed transitions are of particular interest for the understanding of photoexcited plasmas found in X-ray binaries and active galactic nuclei.

  12. Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometerand a rotating anode x-ray tube:theory and experiments.

    Science.gov (United States)

    Chen, Guang-Hong; Bevins, Nicholas; Zambelli, Joseph; Qi, Zhihua

    2010-06-01

    X-ray differential phase contrast imaging methods, including projection imaging and the corresponding computed tomography (CT), have been implemented using a Talbot interferometer and either a synchrotron beam line or a low brilliance x-ray source generated by a stationary-anode x-ray tube. From small-angle scattering events which occur as an x-ray propagates through a medium, a signal intensity loss can be recorded and analyzed for an understanding of the micro-structures in an image object. This has been demonstrated using a Talbot-Lau interferometer and a stationary-anode x-ray tube. In this paper, theoretical principles and an experimental implementation of the corresponding CT imaging method are presented. First, a line integral is derived from analyzing the cross section of the small-angle scattering events. This method is referred to as small-angle scattering computed tomography (SAS-CT). Next, a Talbot-Lau interferometer and a rotating-anode x-ray tube were used to implement SAS-CT. A physical phantom and human breast tissue sample were used to demonstrate the reconstructed SAS-CT image volumes.

  13. Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Lillaney, Prasheel; Pelc, Norbert [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Bioengineering, Stanford University, Stanford, California 94305 (United States); Shin Mihye [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Hinshaw, Waldo; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Bennett, N. Robert [Department of Radiology, Stanford University, Stanford, California 94305 and Qualcomm MEMS Technologies, San Jose, California 95134 (United States)

    2013-02-15

    Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also

  14. A K-alpha x-ray source using high energy and high repetition rate laser system for phase contrast imaging

    OpenAIRE

    Serbanescu, Cristina; Fourmaux, Sylvain; Kieffer, Jean-Claude; Kincaid, Russell; Krol, Andrzej

    2009-01-01

    K-alpha x-ray sources from laser produced plasmas provide completely new possibilities for x-ray phase-contrast imaging applications. By tightly focusing intense femtosecond laser pulses onto a solid target K-alpha x-ray pulses are generated through the interaction of energetic electrons created in the plasma with the bulk target. In this paper, we present a continuous and efficient Mo K-alpha x-ray source produced by a femtosecond laser system operating at 100 Hz repetition rate with maximum...

  15. Market research and forecast on the rotating anode target of X-ray tube used for CT%CT机X射线管用旋转阳极靶材市场研究与预测

    Institute of Scientific and Technical Information of China (English)

    高丽娜

    2012-01-01

    阐述了CT机X射线管用旋转阳极靶材的工作原理及其常见失效形式。随着CT机市场的日渐壮大。其对旋转阳极靶材的需求将越来越大。文中从3个方面全面阐明了国内CT机X射线管用旋转阳极靶材的市场需求及其产业现状。最后,提出了整合国内旋转阳极靶材行业现有的技术力量,引进专业技术人才,自主研发的建议,以期尽快实现高质量CT机X射线管旋转阳极靶材的国产化。%The paper elaborates the operating principle and common failure forms about rotating anode target of X-ray tube used for CT. The rotating anode target is an important part of X-ray tube, also need regular replacement of wearing parts. It directly effects the intensity of X-ray emitted by the X ray tube and the life of X ray tube. With the growing market of CT, the rotating anode target will be needed more and more. The paper elaborates the market demands and industry situation of rotating anode target of X-ray tube used for CT in China from three aspects. Finally, the author proposes some suggestions on achieving the localization of rotating anode target of X-ray tube used for CT with higher quality as soon as possible, by integrating existing techniques, introducing professional talents, independent research and developmen

  16. Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system.

    Science.gov (United States)

    Lillaney, Prasheel; Shin, Mihye; Hinshaw, Waldo; Bennett, N Robert; Pelc, Norbert; Fahrig, Rebecca

    2013-02-01

    Using hybrid x-ray∕MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine

  17. A K-alpha x-ray source using high energy and high repetition rate laser system for phase contrast imaging.

    Science.gov (United States)

    Serbanescu, Cristina; Fourmaux, Sylvain; Kieffer, Jean-Claude; Kincaid, Russell; Krol, Andrzej

    2009-01-01

    K-alpha x-ray sources from laser produced plasmas provide completely new possibilities for x-ray phase-contrast imaging applications. By tightly focusing intense femtosecond laser pulses onto a solid target K-alpha x-ray pulses are generated through the interaction of energetic electrons created in the plasma with the bulk target. In this paper, we present a continuous and efficient Mo K-alpha x-ray source produced by a femtosecond laser system operating at 100 Hz repetition rate with maximum pulse energy of 110 mJ before compression. The source has an x-ray conversion efficiency of greater than 10(-5) into K-alpha line emission. In preparation for phase contrast imaging applications, the size of the resultant K-alpha x-ray emission spot has been also characterized. The source exhibits sufficient spatial coherence to observe phase contrast. We observe a relatively small broadening of the K-alpha source size compared to the size of the laser beam itself. Detailed characterization of the source including the x-ray spectrum and the x-ray average yield along with phase contrast images of test objects will be presented.

  18. K-alpha X-rays from cosmic ray oxygen. [Detection and calculation of equilibrium charge fractions

    Science.gov (United States)

    Pravdo, S. H.; Boldt, E. A.

    1975-01-01

    Equilibrium charge fractions are calculated for subrelativistic cosmic ray oxygen ions in the interstellar medium. These are used to determine the expected flux of K-alpha rays arising from atomic processes for a number of different postulated interstellar oxygen spectra. Relating these results to the diffuse X-ray background measured at the appropriate energy level suggests an observable line feature. If the flux of low energy cosmic ray oxygen is sufficiently large, K-alpha X-ray line emission from these nuclei will comprise a significant fraction of the total diffuse flux at approximately 0.6 keV. A satellite borne detector with a resolution greater than 30 percent could observe this feature if the subrelativistic interstellar cosmic ray oxygen spectrum is as large as certain theoretical estimates expressed in the text.

  19. SMM observations of K-alpha radiation from fluorescence of photospheric iron by solar flare X-rays

    Science.gov (United States)

    Parmar, A. N.; Culhane, J. L.; Rapley, C. G.; Wolfson, C. J.; Acton, L. W.; Phillips, K. J. H.; Dennis, B. R.

    1984-01-01

    High-resolution Fe K-alpha spectra near 1.94 A observed during solar flares with the Bent Crystal Spectrometer on the Solar Maximum Mission are presented. The evidence for two possible excitation mechanisms, electron impact and fluorescence, is examined. It is found that the fluorescence mechanism satisfactorily describes the results, while the observations do not support electron collisional excitation of the Fe K-alpha transitions in low ionization stages (II-XII) of iron. Using Bai's model of the fluorescent excitation process, the photospheric iron abundance relative to that of hydrogen is estimated to be 5-6 x 10 to the -5th. The mean height of the soft X-ray source producing the K-alpha fluorescence is calculated on the basis of this model for about 40 large flares. The solar K-alpha lines are found to be about 25 percent wider than those measured in the laboratory. Weak line features observed at wavelengths shorter than that of the K-alpha lines are discussed.

  20. Resonant K-alpha spectroscopy of a hot dense plasma created by the LCLS x-ray free electron laser

    Science.gov (United States)

    Cho, Byoung-Ick; Engelhorn, K.; Falcone, R. W.; Heimann, P. A.; Vinko, S. M.; Ciricosta, O.; Higginbotham, A.; Murphy, C.; Wark, J. S.; Chung, H.-K.; Brown, C. R. D.; Burian, T.; Vysin, L.; Juha, L.; Lee, H. J.; Messersmidt, M.; Schlotter, W.; Turner, J.; Nagler, B.; Ping, Y.; Lee, R. W.; Toleikis, S.; Zastrau, U.

    2011-10-01

    We present one of the first experimental studies of the interaction of high intensity x-ray free electron laser radiation with solid density matter. In the experiment performed at the LCLS, an intense 80 fs x-ray pulse at 1017 Wcm-2 with photon energies of 1480 ~ 1560 eV is focused on a thin Al foil and K-alpha emission spectra are observed. Although x-ray photon energy is lower than the absorption edge, because of its high intensity the sample is surprisingly heated up to 100 ~200 eV in the pulse duration and a hot dense plasma is created. Observed x-ray spectra indicate this dense plasma resonantly interacts with the x-ray photons. The emission spectra are also simulated using the collisional-radiative code, SCFLY which provides information about the electron temperature and density, the charge state distribution and opacity. The comparison of experiment and simulation provides a detailed description of a dense plasma resonantly interacting with an intense x-ray pulse.

  1. K(alpha) x-ray emission characterization of 100 Hz, 15 mJ femtosecond laser system with high contrast ratio.

    Science.gov (United States)

    Fourmaux, S; Serbanescu, C; Kincaid, R E; Krol, A; Kieffer, J C

    2008-12-12

    We report K(alpha) x-ray production with a high energy (110 mJ per pulse at 800 nm before compression/15 mJ at 400 nm after compression), high repetition rate (100 Hz), and high pulse contrast (better than 10(-9) at 400 nm) laser system. To develop laser-based x-ray sources for biomedical imaging requires to use high-energy and high-power ultra-fast laser system where compression is achieved under vacuum. Using this type of laser system, we demonstrate long-term stability of the x-ray yield, conversion efficiency higher than 1.5 x 10(-5) with a Mo target, and the x-ray spot size close to the optical focal spot. This high-repetition K(alpha) x-ray source can be very useful for x-ray phase-contrast imaging.

  2. Wavelengths, oscillator strengths and radiative transition rates for K{alpha} lines in titanium x-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Hu Feng; Wang Chuangke; Zhao Xuefeng [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yang Jiamin; Jiang Gang, E-mail: yjm70018@my-public.sc.cninfo.net [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610064 (China)

    2011-06-15

    The oscillator strengths, line strengths and wavelengths are presented for all 1s-2p transitions in titanium ions. X-ray emission from titanium is extensively used, for example for diagnosis, in fusion experiments. The K{alpha} 1s-2p transitions are limited to transitions from helium-like to fluorine-like ion as the 2p subshell is filled beyond fluorine. While there are two 1s-2p transitions (1s{sup 2}S{sub 1/2}-2p{sup 2}P{sub 1/2} and 1s{sup 2}S{sub 1/2}-2p{sup 2}P{sub 3/2}) for hydrogen-like titanium, Ti{sup 20+}, the number varies depending on the number of electrons in the 2p subshell before and after the transition. For example, there are 35 1s-2p transitions giving the same number of K{alpha} lines for carbon-like titanium, Ti{sup 16+}. The present results are obtained from configuration interaction atomic structure calculations using the code GRASPVU, which includes relativistic effects in the Dirac-Fock approximation. The results have been benchmarked for a few ionic states. A comparison of our results with the very few transitions in the literature as well as those from other codes shows reasonable accuracy of the present results.

  3. Complex X-ray Absorption and the Fe Kalpha Profile in NGC 3516

    CERN Document Server

    Turner, T J; George, I M; Reeves, J N; Bottorff, M C

    2004-01-01

    We present data from simultaneous Chandra, XMM-Newton and BeppoSAX observations of the Seyfert 1 galaxy NGC 3516, taken during 2001 April and Nov. We have investigated the nature of the very flat observed X-ray spectrum. Chandra grating data show the presence of X-ray absorption lines, revealing two distinct components of the absorbing gas, one which is consistent with our previous model of the UV/X-ray absorber while the other, which is outflowing at a velocity of ~1100 km/s has a larger column density and is much more highly ionized. The broad-band spectral characteristics of the X-ray continuum observed with XMM during 2001 April, reveal the presence of a third layer of absorption consisting of a very large column (~2.5 x 10E23 cm^-2) of highly ionized gas with a covering fraction ~50%. This low covering fraction suggests that the absorber lies within a few lt-days of the X-ray source and/or is filamentary in structure. Interestingly, these absorbers are not in thermal equilibrium with one another. The two...

  4. Complex X-ray Absorption and the Fe K(alpha) Profile in NGC 3516

    Science.gov (United States)

    Turner, T. J.; Kraemer, S. B.; George, I. M.; Reeves, J. N.; Botorff, M. C.

    2004-01-01

    We present data from simultaneous Chandra, XMM-Newton and BeppoSAX observations of the Seyfert 1 galaxy NGC 3516, taken during 2001 April and November. We have investigated the nature of the very flat observed X-ray spectrum. Chandra grating data show the presence of X-ray absorption lines, revealing two distinct components of the absorbing gas, one which is consistent with our previous model of the UV/X-ray absorber while the other, which is outflowing at a velocity of approximately 1100 kilometers per second, has a larger column density and is much more highly ionized. The broad-band spectral characteristics of the X-ray continuum observed with XMM during 2001 April, reveal the presence of a third layer of absorption consisting of a very large column (approximately 2.5 x 10(exp 23) per square centimeter) of highly ionized gas with a covering fraction approximately 50%. This low covering fraction suggests that the absorber lies within a few 1t-days of the X-ray source and/or is filamentary in structure. Interestingly, these absorbers are not in thermal equilibrium with one another. The two new components are too highly ionized to be radiatively accelerated, which we suggest is evidence for a hydromagnetic origin for the outflow. Applying our model to the November dataset, we can account for the spectral variability primarily by a drop in the ionization states of the absorbers, as expected by the change in the continuum flux. When this complex absorption is accounted for we find the underlying continuum to be typical of Seyfert 1 galaxies. The spectral curvature attributed to the high column absorber, in turn, reduces estimates of the flux and extent of any broad Fe emission line from the accretion disk.

  5. Ultra-fast Measurements of Optically Induced Lattice Dynamics in LuMnO3 Using Aluminum K-alpha X-Ray Diffraction.

    Science.gov (United States)

    Workman, J.; Wark, J. S.

    2005-10-01

    An experiment to study the structural dynamics at the ultra-fast time scale in optically-pumped samples is presented. Measurements of lattice dynamics in LuMnO3 are presented and compared to calculations using dynamical diffraction theory modified for hexagonal crystal structure. Ultra-fast x-ray emission is used to measure Bragg peak shifts using diffraction and compared to calculations. Results are presented for optical pump energy densities of 8 and 20-mJ/cm^2. The experiment uses ˜150 mJ of a 100fs Ti:Sapphire laser to excite K-alpha x-ray emission in an aluminum wire with ˜1-2% split off for the material pump. The x-ray emission is relayed using a spherical Quartz crystal to the sample target. Plans for experiments using Cu K-alpha emission to probe Fe samples will also be described.

  6. Characterisation of NEXT-DEMO using xenon K$_{\\alpha}$ X-rays

    CERN Document Server

    Lorca, D; Laing, A; Ferrario, P; Gómez-Cadenas, J J; Álvarez, V; Borges, F I G; Camargo, M; Cárcel, S; Cebrián, S; Cervera, A; Conde, C A N; Dafni, T; Díaz, J; Esteve, R; Fernandes, L M P; Ferreira, A L; Freitas, E D C; Gehman, V M; Goldschmidt, A; Gómez, H; González-Díaz, D; Gutiérrez, R M; Hauptman, J; Morata, J A Hernando; Herrera, D C; Irastorza, I G; Labarga, L; Liubarsky, I; Losada, M; Luzón, G; Marí, A; Martínez-Lema, G; Martínez, A; Miller, T; Monrabal, F; Monserrate, M; Monteiro, C M B; Mora, F J; Moutinho, L M; Vidal, J Muñoz; Nebot-Guinot, M; Nygren, D; Oliveira, C A B; Pérez, J; Aparicio, J L Pérez; Renner, J; Ripoll, L; Rodríguez, A; Rodríguez, J; Santos, F P; Santos, J M F dos; Seguí, L; Serra, L; Shuman, D; Simón, A; Sofka, C; Sorel, M; Toledo, J F; Torrent, J; Tsamalaidze, Z; Veloso, J F C A; Webb, R; White, J T; Yahlali, N

    2014-01-01

    The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of p...

  7. MCDF-RCI predictions for structure and width of $K\\alpha_{1,2}$ x-ray line of Al and Si

    CERN Document Server

    Kozioł, Karol

    2014-01-01

    Multiconfiguration Dirac-Fock and Relativistic Configuration Interaction methods have been employed to predict the structure and the width of $K\\alpha_{1,2}$ x-ray lines of Al and Si. The influences of electron correlation and inclusion of possible satellite contributions on spectra structure have been studied. The widths of $K$ and $L_{2,3}$ atomic levels of Al and Si have been also computed.

  8. The narrow Fe K$\\alpha$ line and the molecular torus in active galactic nuclei - an IR/X-ray view

    CERN Document Server

    Ricci, Claudio; Ichikawa, Kohei; Paltani, Stephane; Boissay, Rozenn; Gandhi, Poshak; Stalevski, Marko; Awaki, Hisamitsu

    2014-01-01

    The narrow component of the iron K$\\alpha$ is an almost ubiquitous feature in the X-ray spectra of active galactic nuclei (AGN) and is believed to originate in neutral material, possibly located in the molecular torus. This would imply a tight connection between the Fe K$\\alpha$ equivalent width (EW) and the physical properties of the torus. In a recent work we have shown that the decrease of the covering factor of the torus with the luminosity, as expected by luminosity-dependent unification models, would be able to explain the decrease of Fe K$\\alpha$ EW with the luminosity (i.e., the X-ray Baldwin effect). Recent developments in the study of the mid-IR (MIR) spectrum of AGN allow important parameters of the torus to be deduced, such as its covering factor ($f_{\\rm\\,obs}$) and equatorial column density ($N_{\\rm\\,H}^{\\rm\\,T}$), by applying clumpy torus models. Using XMM-Newton/EPIC observations of a sample of 24 type-I AGN, we investigate the relation between the physical parameters of the torus obtained by ...

  9. Method for characterization of a spherically bent crystal for K.alpha. X-ray imaging of laser plasmas using a focusing monochromator geometry

    Science.gov (United States)

    Kugland, Nathan; Doeppner, Tilo; Glenzer, Siegfried; Constantin, Carmen; Niemann, Chris; Neumayer, Paul

    2015-04-07

    A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.

  10. An intense and broad FeKalpha line observed in the X-ray luminous quasar Q0056-363 with XMM-Newton

    CERN Document Server

    Porquet, D; Porquet, Delphine

    2003-01-01

    We present an XMM-Newton observation of the radio-quiet quasar Q0056-363 (z=0.162). This is the first time that this quasar is observed in the hard X-ray range (above 2 keV). We find that Q0056-363 is a powerful X-ray quasar, with a 0.3-12 keV unabsorbed luminosity of about 1.2 x 10^45 erg s-1 with the largest part (~67%) emitted below 2 keV. The spectrum reveals a large featureless soft X-ray excess below 2 keV and a strong broad FeKalpha line at 6.4 keV (in the quasar frame). The FeK alpha line is due to low to moderate ionization states of iron (i.e., < Fe XVII), with an equivalent width of about 250 eV and a velocity width of about 25,000 km s-1. Q0056-363 is presently the most luminous AGN known to exhibit such a broad and intense FeKalpha line profile from near neutral iron. The line can be fitted with a relativistic profile from an accretion disc around either a Schwarzschild (non-rotating) or a Kerr (rotating) black hole. A combination of two thermal Comptonization components and a disc reflection ...

  11. The Seyfert 2 galaxy NGC 2110: hard X-ray emission observed by NuSTAR and variability of the iron K$\\alpha$ line

    CERN Document Server

    Marinucci, A; Bianchi, S; Lu, T N; Arevalo, P; Baloković, M; Ballantyne, D; Bauer, F E; Boggs, S E; Christensen, F E; Craig, W W; Gandhi, P; Hailey, C J; Harrison, F; Puccetti, S; Rivers, E; Walton, D J; Stern, D; Zhang, W

    2014-01-01

    We present NuSTAR observations of the bright Seyfert 2 galaxy NGC 2110 obtained in 2012, when the source was at the highest flux level ever observed, and in 2013, when the source was at a more typical flux level. We include archival observations from other X-ray satellites, namely XMM-Newton, Suzaku, BeppoSAX, Chandra and Swift. Simultaneous NuSTAR and Swift broad band spectra (in the 3-80 keV range) indicate a cutoff energy $E_{\\rm c}>210$ keV, with no detectable contribution from Compton reflection. NGC 2110 is one of the very few sources where no evidence for distant Compton thick scattering is found and, by using temporal information collected over more than a decade, we investigate variations of the iron K$\\alpha$ line on time scales of years. The Fe K$\\alpha$ line is likely the sum of two components: one constant (originating from distant Compton-thick material) and the other one variable and linearly correlated with the source flux (possibly arising from Compton-thin material much closer to the black h...

  12. The ASCA X-Ray Spectrum Of The Broad-Line Radio Galaxy Pictor A A Simple Power Law With No Fe K-$\\alpha$ Line

    CERN Document Server

    Eracleous, M; Eracleous, Michael; Halpern, Jules P.

    1998-01-01

    We present the X-ray spectrum of the broad-line radio galaxy Pictor A as observed by ASCA in 1996. The main objective of the observation was to detect and study the profiles of the Fe~K$\\alpha$ lines. The motivation was the fact that the Balmer lines of this object show well-separated displaced peaks, suggesting an origin in an accretion disk. The 0.5-10 keV X-ray spectrum is described very well by a model consisting of a power law of photon index 1.77 modified by interstellar photoelectric absorption. We find evidence for neither a soft nor a hard (Compton reflection) excess. More importantly, we do not detect an Fe K-alpha line, in marked contrast with the spectra of typical Seyfert galaxies and other broad-line radio galaxies observed by ASCA. The 99%-confidence upper limit on the equivalent width of an unresolved line at a rest energy of 6.4 keV is 100 eV, while for a broad line (FWHM of approximately 60,000 km/s) the corresponding upper limit is 135 eV. We discuss several possible explanations for the we...

  13. Sensitivity of the Fe K-alpha Compton shoulder to the geometry and variability of the X-ray illumination of cosmic objects

    CERN Document Server

    Odaka, Hirokazu; Takahashi, Tadayuki; Fabian, Andrew

    2016-01-01

    In an X-ray reflection spectrum, a tail-like spectral feature generated via Compton down-scattering, known as a Compton shoulder (CS), appears at the low-energy side of the iron K$\\alpha$ line. Despite its great diagnostic potential, its use as a spectral probe of the reflector has been seriously limited due to observational difficulties and modelling complexities. We revisit the basic nature of the CS by systematic investigation into its dependence on spatial and temporal parameters. The calculations are performed by Monte-Carlo simulations for sphere and slab geometries. The dependence is obtained in a two-dimensional space of column density and metal abundance, demonstrating that the CS solves parameter degeneration between them which was seen in conventional spectral analysis using photoelectric absorption and fluorescence lines. Unlike the iron line, the CS does not suffer from any observational dependence on the spectral hardness. The CS profile is highly dependent on the inclination angle of the slab g...

  14. The Seyfert 2 Galaxy NGC 2110: Hard X-Ray Emission Observed by NuStar and Variability of the Iron K-Alpha Line

    Science.gov (United States)

    Marinucci, A.; Matt, G.; Bianchi, S.; Lu, T. N.; Arevalo, P.; Balokovic, M.; Ballantyne, D.; Bauer, F. E.; Boggs, S. E.; Stern, D.; Zhang, William W.

    2014-01-01

    We present NuSTAR observations of the bright Seyfert 2 galaxy NGC 2110 obtained in 2012, when the source was at the highest flux level ever observed, and in 2013, when the source was at a more typical flux level. We include archival observations from other X-ray satellites, namely XMM-Newton, Suzaku, BeppoSAX, Chandra and Swift. Simultaneous NuSTAR and Swift broad band spectra (in the 3-80 keV range) indicate a cutoff energy E(sub c) greater than 210 keV, with no detectable contribution from Compton reflection. NGC 2110 is one of the very few sources where no evidence for distant Compton thick scattering is found and, by using temporal information collected over more than a decade, we investigate variations of the iron K(alpha) line on time scales of years. The Fe K alpha line is likely the sum of two components: one constant (originating from distant Compton-thick material) and the other one variable and linearly correlated with the source flux (possibly arising from Compton-thin material much closer to the black hole).

  15. High energy x-ray reflectivity and scattering study from spectrum-x-gamma flight mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Budtz-Jørgensen, Carl; Frederiksen, P. Kk

    1993-01-01

    Line radiation from Fe K-alpha(1), Cu K-alpha(1), and Ag K-alpha(1) is used to study the high energy X-ray reflectivity and scattering behavior of flight-quality X-ray mirrors having various Al substrates. When both the specular and the scattered radiation are integrated, near theoretical...

  16. High energy x-ray reflectivity and scattering study from spectrum-x-gamma flight mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Budtz-Jørgensen, Carl; Frederiksen, P. Kk

    1993-01-01

    Line radiation from Fe K-alpha(1), Cu K-alpha(1), and Ag K-alpha(1) is used to study the high energy X-ray reflectivity and scattering behavior of flight-quality X-ray mirrors having various Al substrates. When both the specular and the scattered radiation are integrated, near theoretical...

  17. Optimization of cold K-alpha emission using copper foams

    Science.gov (United States)

    Hussein, Amina; Hager, Jonathan; Flippo, Kirk

    2015-11-01

    Experiments were conducted at the Trident Laser Facility to increase the conversion efficiency of short-pulse, copper K-alpha x-ray backlighter sources. New target designs using copper foams are in development to investigate the role of underdense/near-critical density targets on the optimization of cold K-alpha emission. K-alpha emission was measured using Highly Ordered Pyrolytic Graphic (HOPG) and imaged with a toroidally bent quartz crystal to determine uniformity, spatial resolution and conversion efficiency of the new designs. Results from this experiment will help inform the development of short-pulse Cu K-alpha back-lighters on facilities like Omega, OmegaEP and the NIF, with a particular emphasis on creating advanced narrow-band backlighter sources capable of producing strong signal to noise with high x-ray fluxes.

  18. Characterization of X-Ray Diffraction System with a Microfocus X-Ray Source and a Polycapillary Optic

    Science.gov (United States)

    Gubarev, Mikhail; Marshall, Joy K.; Ciszak, Ewa; Ponomarev, Igor

    2000-01-01

    We present here an optimized microfocus x-ray source and polycapillary optic system designed for diffraction of small protein crystals. The x-ray beam is formed by a 5.5mm focal length capillary collimator coupled with a 40 micron x-ray source operating at 46Watts. Measurements of the x-ray flux, the divergence and the spectral characteristics of the beam are presented, This optimized system provides a seven fold greater flux than our recently reported configuration [M. Gubarev, et al., J. of Applied Crystallography (2000) 33, in press]. We now make a comparison with a 5kWatts rotating anode generator (Rigaku) coupled with confocal multilayer focusing mirrors (Osmic, CMF12- 38Cu6). The microfocus x-ray source and polycapillary collimator system delivers 60% of the x-ray flux from the rotating anode system. Additional ways to improve our microfocus x-ray system, and thus increase the x-ray flux will be discussed.

  19. Focused beam total reflection X-ray fluorescence with low power sources coupled to doubly curved crystal optics

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z.W. [X-ray Optical Systems, Inc. East Greenbush, NY 12061 (United States)]. E-mail: zchen@xos.com; Mail, N. [Center For X-ray Optics, State University of New York, University at Albany (United States); Wei, F.Z. [X-ray Optical Systems, Inc. East Greenbush, NY 12061 (United States); MacDonald, C.A. [Center For X-ray Optics, State University of New York, University at Albany (United States); Gibson, W.M. [X-ray Optical Systems, Inc. East Greenbush, NY 12061 (United States)

    2005-04-30

    A focused beam total X-ray fluorescence technique was developed based on doubly curved crystal optics. This technique provides good detection sensitivity and spatial resolution for localized detection of surface deposits. Compact low power X-ray sources were used to demonstrate the benefit of the X-ray optics for focusing Cr K{alpha}, Cu K{alpha} and Mo K{alpha} radiation. The detection capability of the focused beam Total reflection X-ray fluorescence system was investigated with dried droplets of calibrated low concentration solutions. Detection limits at the femtogram level were demonstrated.

  20. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  1. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  2. A Compact X-Ray System for Macromolecular Crystallography. 5

    Science.gov (United States)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for macromolecular crystallography that combines a microfocus x-ray generator (40 gm FWHM spot size at a power level of 46.5Watts) and a 5.5 mm focal distance polycapillary optic. The Cu K(sub alpha) X-ray flux produced by this optimized system is 7.0 times above the X-ray flux previously reported. The X-ray flux from the microfocus system is also 3.2 times higher than that produced by the rotating anode generator equipped with a long focal distance graded multilayer monochromator (Green optic; CMF24-48-Cu6) and 30% less than that produced by the rotating anode generator with the newest design of graded multilayer monochromator (Blue optic; CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 Watts, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42,540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym) 5.0% for the data extending to 1.7A, and 4.8% for the complete set of data to 1.85A. The amplitudes of the reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  3. A Compact X-Ray System for Macromolecular Crystallography

    Science.gov (United States)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Gibson, Walter; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for a macromolecular crystallography that combines a microfocus x-ray generator (40 micrometer full width at half maximum spot size at a power level of 46.5 W) and a collimating polycapillary optic. The Cu Ka lpha x-ray flux produced by this optimized system through a 500,um diam orifice is 7.0 times greater than the x-ray flux previously reported by Gubarev et al. [M. Gubarev et al., J. Appl. Crystallogr. 33, 882 (2000)]. The x-ray flux from the microfocus system is also 2.6 times higher than that produced by a rotating anode generator equipped with a graded multilayer monochromator (green optic, Osmic Inc. CMF24-48-Cu6) and 40% less than that produced by a rotating anode generator with the newest design of graded multilayer monochromator (blue optic, Osmic, Inc. CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 W, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42 540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym)=5.0% for data extending to 1.70 A, and 4.8% for the complete set of data to 1.85 A. The amplitudes of the observed reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  4. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all......Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...

  5. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all......Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...

  6. Chest X Ray?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Chest X Ray A chest x ray is a fast and painless imaging test ... tissue scarring, called fibrosis. Doctors may use chest x rays to see how well certain treatments are ...

  7. X-Rays

    Science.gov (United States)

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  8. Medical X-Rays

    Science.gov (United States)

    ... Benefits The discovery of X-rays and the invention of CT represented major advances in medicine. X- ... in X-ray and CT Examinations — X-ray definition, dose measurement, safety precautions, risk, and consideration with ...

  9. Multimessenger astronomy with pulsar timing and X-ray observations of massive black hole binaries

    CERN Document Server

    Sesana, A; Reynolds, M T; Dotti, M

    2011-01-01

    We demonstrate that very massive (>10^8\\msun), cosmologically nearby (z10^-13 erg s^-1 cm^-2 will be in the reach of upcoming X-ray observatories. Double relativistic K\\alpha lines may be observable in a handful of low redshift (z<0.3) sources by proposed deep X-ray probes, such as Athena. (Abridged)

  10. Characteristic x-ray emission from undermines plasmas irradiated by ultra-intense lasers

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Christoph [Univ. of California, Los Angeles, CA (United States)

    2012-05-05

    Between FY09 and FY11 we have conducted more than a dozen three-week experimental campaigns at high-power laser facilities around the world to investigate laser-channeling through x-ray and optical imaging and the conversion from laser-energy to xrays. We have performed simultaneous two-wavelength x-ray imaging (K-alpha and He-alpha) to distinguish the hot-plasma region (hot-spot) from the laser-produced electrons (K-alpha). In addition, we have initiated a new collaboration with SNL and have performed first shots on the 100 TW beamlet chamber to commission a fast x-ray streak camera to be used to investigate the temporal evolution of our K-alpha sources. We also collaborated on campaigns at the Rutherford Appleton Laboratory (UK) and the LANL Trident laser to employ laser produced x-ray sources for Thomson scattering off dense matter.

  11. Extremity x-ray

    Science.gov (United States)

    ... degenerative) Bone tumor Broken bone (fracture) Dislocated bone Osteomyelitis (infection) Arthritis Other conditions for which the test ... Bone tumor Bone x-ray Broken bone Clubfoot Osteomyelitis X-ray Review Date 7/3/2016 Updated ...

  12. Abdominal x-ray

    Science.gov (United States)

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Assistant Studies, Department of Family Medicine, UW Medicine, School of Medicine, University of Washington, Seattle, WA. Also ...

  13. X-Ray Supernovae

    CERN Document Server

    Immler, S; Immler, Stefan; Lewin, Walter H.G.

    2002-01-01

    We present a review of X-ray observations of supernovae (SNe). By observing the (~0.1--100 keV) X-ray emission from young SNe, physical key parameters such as the circumstellar matter (CSM) density, mass-loss rate of the progenitor and temperature of the outgoing and reverse shock can be derived as a function of time. Despite intensive search over the last ~25 years, only 15 SNe have been detected in X-rays. We review the individual X-ray observations of these SNe and discuss their implications as to our understanding of the physical processes giving rise to the X-ray emission.

  14. Broad Band X-Ray Observations of the Narrow Line X-Ray Galaxy NGC 5506

    CERN Document Server

    Wang, T G; Otani, C; Matsuoka, M; Awaki, H

    1999-01-01

    We present a detailed analysis of broad band X-ray data of the Seyfert 2 galaxy NGC5506. 2-10 keV band are detected during a 1-day ASCA observation, while no significant change in the 2-10 keV continuum shape is found. The ASCA spectrum consists of an absorbed power-law, a 'soft excess' below 2 keV, and an Fe K$\\alpha$ emission line at 6.4 keV. The 'soft excess' can be well described by either thermal emission from very low abundance material at a temperature kT$\\simeq$0.8 keV, or scattered/leaking flux from the primary power-law plus a small amount of thermal emission. Analysis of ROSAT HRI data reveals that the soft X-ray emission is extended on kpc scales in this object, and the extended component may account for most of the soft X-ray excess observed by the ASCA. The result suggests that in this type 2 AGN, the 'soft excess' at least partly comes from an extended region, imposing serious problem for the model in which the source is partially covered. Fe K$\\alpha$ profile is complex and can not be satisfac...

  15. Strain measurement of pure titanium covered with soft tissue using X-ray diffraction.

    Science.gov (United States)

    Fujisaki, Kazuhiro; Tadano, Shigeru

    2010-03-01

    Measurement of the stress and strain applied to implants and bone tissue in the human body are important for fracture prediction and evaluations of implant adaptation. The strain of titanium (Ti) materials can be measuring by X-ray diffraction techniques. This study applied X-ray diffraction to the skin tissue-covered Ti. Characteristic X-rays of Mo Kalpha were used and the X-rays diffracted from the Ti were detected through the covering skin tissue. The X-ray absorption by skin tissue is large under the diffracted X-rays detected in low angles because the length of penetration depends on the angle of inclination, equal to the Bragg angle. The effects of skin tissue to detect the diffracted X-rays were investigated in the experiments. And the strain measurements were conducted under bending loads applied to the Ti specimen. The effect of skin tissue was absorption of X-rays as well as the X-rays scattered from the physiological saline contained in the tissue. The X-rays scattered by the physiological saline creates a specific background pattern near the peaks from the (002) and (011) lattice planes of Ti in the X-ray diffraction profile. Diffracted X-rays from the Ti were detected after being transmitted through 1 mm thick skin tissue by Mo Kalpha. Individual peaks such as (010), (002), (011), and (110) were clearly established by using a parallel beam arrangement. The strains of (110) lattice planes were measured with or without the tissue cover were very similar. The strain of the (110) lattice planes of Ti could be measured by Mo Kalpha when the Ti specimen was located under the skin tissue.

  16. X-Ray Polarimetry

    CERN Document Server

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.

  17. X-Ray

    Science.gov (United States)

    ... You may be allowed to remain with your child during the test. If you remain in the room during the X-ray exposure, you'll likely be asked to wear a lead apron to shield you from unnecessary exposure. After the X-ray ...

  18. Dental x-rays

    Science.gov (United States)

    ... X-rays are a form of high energy electromagnetic radiation. The x-rays penetrate the body to form ... for detecting cavities, unless the decay is very advanced and deep. Many ... The amount of radiation given off during the procedure is less than ...

  19. X-Ray Surveys

    CERN Document Server

    Giommi, P; Perri, M

    1998-01-01

    A review of recent developments in the field of X-ray surveys, especially in the hard (2-10 and 5-10 keV) bands, is given. A new detailed comparison between the measurements in the hard band and extrapolations from ROSAT counts, that takes into proper account the observed distribution of spectral slopes, is presented. Direct comparisons between deep ROSAT and BeppoSAX images show that most hard X-ray sources are also detected at soft X-ray energies. This may indicate that heavily cutoff sources, that should not be detectable in the ROSAT band but are expected in large numbers from unified AGN schemes, are in fact detected because of the emerging of either non-nuclear components, or of reflected, or partially transmitted nuclear X-rays. These soft components may complicate the estimation of the soft X-ray luminosity function and cosmological evolution of AGN.

  20. X-ray Polarimetry

    Science.gov (United States)

    Kallman, T.

    In spite of the recent advances in X-ray instrumentation, polarimetry remains an area which has been virtually unexplored in the last 20 years. The scientific motivation to study polarization has increased during this time: emission models designed to repro- duce X-ray spectra can be tested using polarization, and polarization detected in other wavelength bands makes clear predictions as to the X-ray polarization. Polarization remains the only way to infer geometrical properties of sources which are too small to be spatially resolved. At the same time, there has been recent progress in instrumen- tation which is likely to allow searches for X-ray polarization at levels significantly below what was possible for early detectors. In this talk I will review the history of X-ray polarimetry, discuss some experimental techniques and the scientific problems which can be addressed by future experiments.

  1. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  2. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  3. X-Ray Line Measurements with High Efficiency Bragg Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Pak, A; Gregori, G; Knight, J; Campbell, K; Landen, O; Glenzer, S

    2004-04-01

    We have studied the focusing properties of two highly oriented pyrolitic graphite (HOPG) spectrometers, which differ in the degree of the mosaic spread: ZYA with a low mosaic spread ({gamma}=0.4 degrees) and ZYH with a large mosaic spread ({gamma}=3.5 degrees). In order to assess the crystal performance for a variety of different experiments, various K{alpha} and K{beta} x-ray lines have been produced using a high-intensity ({approx}>10{sup 17} W/cm{sup 2}) short-pulse ({approx} 100 fs) laser beam focused onto Ti, V, Zn, and Cu foils. The measured spectral resolution of the HOPG crystals in both first and second order diffraction has been compared with theoretical predictions. Using known values for the peak reflectivity of HOPG crystals, we have also computed K{alpha} x-ray conversion efficiencies of Ti, V, Zn, and Cu. These results are important to estimate the optimal conditions under which different types of HOPG monochromators can be used for the detection of weak x-ray signals as the one encountered in x-ray Thomson/Compton scattering experiments.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  5. Iron K$\\alpha$ emission in type-I and type-II Active Galactic Nuclei

    CERN Document Server

    Ricci, Claudio; Paltani, Stephane; Ichikawa, Kohei; Gandhi, Poshak; Awaki, Hisamitsu

    2014-01-01

    The narrow Fe K$\\alpha$ line is one of the main signatures of the reprocessing of X-ray radiation from the material surrounding supermassive black holes, and it has been found to be omnipresent in the X-ray spectra of active galactic nuclei (AGN). In this work we study the characteristics of the narrow Fe K$\\alpha$ line in different types of AGN. Using the results of a large Suzaku study we find that Seyfert 2s have on average lower Fe K$\\alpha$ luminosities than Seyfert 1s for the same 10-50 keV continuum luminosity. Simulating dummy Sy1s and Sy2s populations using physical torus models of X-ray reflected emission, we find that this difference can be explained by means of different average inclination angles with respect to the torus, as predicted by the unified model. Alternative explanations include differences in the intensities of Compton humps or in the photon index distributions. We show that the ratio between the flux of the broad and narrow Fe K$\\alpha$ line in the 6.35-6.45 keV range depends on the ...

  6. High-resolution x-ray scatter and reflectivity study of sputtered IR surfaces

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Abdali, S.; Hornstrup, Allan

    1993-01-01

    In recent years there has been an increased interest in the possible use of Ir as the reflecting surface in X-ray telescope programs. An X-ray study of such surfaces produced by sputtering of Ir on highly polished Zerodur flats is presented here. The study was performed using Fe K(alpha) 1 (6.......404 Kev) and Cu K(alpha) 1 (8.048 keV) and includes measurement of total external reflection and scattering. The scattering measurement was made with three different instruments arrangements; one employed a 1D position sensitive detector for low resolution studies giving approximately 30 arcsec resolution...... (FWHM), and the other two arrangements employed channel cut crystals providing resolutions (FWHM) of 5 arcsec and 1 arcsec, respectively at Cu K(alpha) 1. The reflectivity study revealed a very close correspondence with a theoretical model based on recently published optical constants. This important...

  7. High-resolution x-ray scatter and reflectivity study of sputtered IR surfaces

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Abdali, S.; Hornstrup, Allan

    1993-01-01

    In recent years there has been an increased interest in the possible use of Ir as the reflecting surface in X-ray telescope programs. An X-ray study of such surfaces produced by sputtering of Ir on highly polished Zerodur flats is presented here. The study was performed using Fe K(alpha) 1 (6.......404 Kev) and Cu K(alpha) 1 (8.048 keV) and includes measurement of total external reflection and scattering. The scattering measurement was made with three different instruments arrangements; one employed a 1D position sensitive detector for low resolution studies giving approximately 30 arcsec resolution...... (FWHM), and the other two arrangements employed channel cut crystals providing resolutions (FWHM) of 5 arcsec and 1 arcsec, respectively at Cu K(alpha) 1. The reflectivity study revealed a very close correspondence with a theoretical model based on recently published optical constants. This important...

  8. Bone x-ray

    Science.gov (United States)

    ... or broken bone Bone tumors Degenerative bone conditions Osteomyelitis (inflammation of the bone caused by an infection) ... Multiple myeloma Osgood-Schlatter disease Osteogenesis imperfecta Osteomalacia Osteomyelitis Paget disease of the bone Rickets X-ray ...

  9. Hand x-ray

    Science.gov (United States)

    ... include fractures, bone tumors , degenerative bone conditions, and osteomyelitis (inflammation of the bone caused by an infection). ... chap 46. Read More Bone tumor Broken bone Osteomyelitis X-ray Review Date 9/8/2014 Updated ...

  10. Pelvis x-ray

    Science.gov (United States)

    X-ray - pelvis ... Tumors Degenerative conditions of bones in the hips, pelvis, and upper legs ... hip joint Tumors of the bones of the pelvis Sacroiliitis (inflammation of the area where the sacrum ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight October is National Breast Cancer Awareness Month Recently posted: Medical Imaging Costs Magnetoencephalography ( ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  14. X-ray - skeleton

    Science.gov (United States)

    ... x-ray particles pass through the body. A computer or special film records the images. Structures that ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  15. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  17. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... diagnosis and disease management. top of page How is the procedure performed? The technologist, an individual specially ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  5. High-resolution x-ray studies of an AXAF high-energy transmission grating

    DEFF Research Database (Denmark)

    Abdali, S.; Christensen, Finn Erland; Schnopper, H. W.

    1993-01-01

    A triple axis X-ray diffractometer, designed and built at the Danish Space Research Institute, was used to make a high resolution study of the performance of a 2000 angstroms period, high energy X-ray transmission grating developed at MIT for one of the grating spectrometers on the Advanced X-ray...... Astrophysics Facility. Data was obtained at CuK(alpha )1 (8.048 keV) and, using single reflection asymmetric Si(044) crystals for both the monochromator and analyzer, an angular resolution of 1.5 arcsec FWHM was achieved. The efficiency of the grating in all orders up to the 15th was measured using a 12 k......W rotating anode X-ray generator. These data provided the basis for a modelling of the grating structure....

  6. High-resolution x-ray studies of an AXAF high-energy transmission grating

    DEFF Research Database (Denmark)

    Abdali, S.; Christensen, Finn Erland; Schnopper, H. W.

    1993-01-01

    A triple axis X-ray diffractometer, designed and built at the Danish Space Research Institute, was used to make a high resolution study of the performance of a 2000 angstroms period, high energy X-ray transmission grating developed at MIT for one of the grating spectrometers on the Advanced X-ray...... Astrophysics Facility. Data was obtained at CuK(alpha )1 (8.048 keV) and, using single reflection asymmetric Si(044) crystals for both the monochromator and analyzer, an angular resolution of 1.5 arcsec FWHM was achieved. The efficiency of the grating in all orders up to the 15th was measured using a 12 k......W rotating anode X-ray generator. These data provided the basis for a modelling of the grating structure....

  7. Developing small vacuum spark as an x-ray source for calibration of an x-ray focusing crystal spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ghomeishi, Mostafa; Adikan, Faisal Rafiq Mahamd [Photonic Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Karami, Mohammad [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2012-10-15

    A new technique of x-ray focusing crystal spectrometers' calibration is the desired result. For this purpose the spectrometer is designed to register radiated copper K{alpha} and K{beta} lines by using a flat {alpha}-quartz crystal. This experiment uses pre-breakdown x-ray emissions in low vacuum of about 2.5-3 mbar. At this pressure the pinch will not form so the plasma will not radiate. The anode material is copper and the capacity of the capacitor bank is 22.6 nF. This experiment designed and mounted a repetitive triggering system to save the operator time making hundreds of shots. This emission amount is good for calibration and geometrical adjustment of an optical crystal x-ray focusing spectrometer.

  8. Trace chemical characterization using monochromatic X-ray undulator radiation

    Science.gov (United States)

    Eba; Numako; Iihara; Sakurai

    2000-06-01

    An efficient Johansson-type X-ray fluorescence spectrometer has been developed for advanced X-ray spectroscopic analysis with third-generation synchrotron radiation. Kalpha and Kbeta X-ray fluorescence spectra for trace metals have been collected by a Ge(220) analyzing crystal with a Rowland radius of 150 mm, under monochromatic X-ray excitation at the undulator beamline at the SPring-8. The energy resolution is approximately 10 eV for most of the K lines for 3d transition metals. In light of the greatly improved efficiency, as well as the excellent signal-to-background ratio, the relative and absolute detection limits achieved are 1 ppm and 1.2 ng of copper in a carbon matrix, respectively. The energy resolution of the present spectrometer permits the observation of some chemical effects in Kbeta spectra. It has been demonstrated that the changes in Kbeta5 and Kbeta'' intensity for iron and cobalt compounds can be used for the analysis of chemical states. Resonant X-ray fluorescent spectra are another important application of monochromatic excitation. In view of trace chemical characterization, the present spectrometer can be a good alternative to a conventional Si(Li) detector system when combined with highly brilliant X-rays.

  9. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  10. X-ray Pulsars

    CERN Document Server

    Walter, Roland

    2016-01-01

    X-ray pulsars shine thanks to the conversion of the gravitational energy of accreted material to X-ray radiation. The accretion rate is modulated by geometrical and hydrodynamical effects in the stellar wind of the pulsar companions and/or by instabilities in accretion discs. Wind driven flows are highly unstable close to neutron stars and responsible for X-ray variability by factors $10^3$ on time scale of hours. Disk driven flows feature slower state transitions and quasi periodic oscillations related to orbital motion and precession or resonance. On shorter time scales, and closer to the surface of the neutron star, X-ray variability is dominated by the interactions of the accreting flow with the spinning magnetosphere. When the pulsar magnetic field is large, the flow is confined in a relatively narrow accretion column, whose geometrical properties drive the observed X-ray emission. In low magnetized systems, an increasing accretion rate allows the ignition of powerful explosive thermonuclear burning at t...

  11. X-ray state analysis by means of electron capture decay

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, Yoichi [Miyagi Univ. of Education, Sendai (Japan)

    1998-01-01

    K{alpha} X-ray induced by EC decay of {sup 55}Fe and {sup 71}Ge-labeled compounds were measured by wavelength dispersive X-ray spectrometer equipped position sensitive proportional detector. In both nuclides, peak energies of K{alpha}{sub 2} X-rays are lower (-0.4 - -0.6 eV) than those of Mn and Ga compounds by photoionization. It is thought that the causes of these differences are intensity of high energy satellite peaks by shake up process. (author)

  12. X-Ray Protection

    Science.gov (United States)

    1955-01-01

    15,000. • When developed In Kodak liquid X-ray developer for 5 min at a temperature of 200 C. b Film sensitivities vary with photon energy by the...for example temporomandibular -joint exposures where a skin dose of 25 r or more may be obtained during a single exposure with 65 kvp, 1.5 mm aluminum...communication. W. J. Updegrave, Temporomandibular articulation-X-ray examina- tion, Dental Radiography and Photography 26, No. 3, 41 (1953). H. 0. Wyckoff, R. J

  13. X-ray Reflection

    Science.gov (United States)

    Fabian, A. C.; Ross, R. R.

    2010-12-01

    Material irradiated by X-rays produces backscattered radiation which is commonly known as the Reflection Spectrum. It consists of a structured continuum, due at high energies to the competition between photoelectric absorption and electron scattering enhanced at low energies by emission from the material itself, together with a complex line spectrum. We briefly review the history of X-ray reflection in astronomy and discuss various methods for computing the reflection spectrum from cold and ionized gas, illustrated with results from our own work reflionx. We discuss how the reflection spectrum can be used to obtain the geometry of the accretion flow, particularly the inner regions around black holes and neutron stars.

  14. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  15. Comparing the Ag-content of poltinniks using X-ray fluorescence

    CERN Document Server

    Ferguson, S

    2013-01-01

    X-ray fluorescence experiments have been performed in order to analyze the elemental composition of four Russian 50-kopek coins ("poltinniks") minted during 1913, 1921, and 1924. By comparing the intensities of the Ag K{\\alpha} X-rays emitted by the poltinniks, we were able to determine whether the Ag-content of the coins were equal. One of the goals of this study was to determine whether or not legislation was carried out that required the proportions of Ag and Cu used in the minting of coins in 1924 to be identical to those minted in previous years. Also, the intensities of the Ag K{\\alpha} X-rays emitted by 1924 poltinniks minted in London and Leningrad were compared. Our results suggest that the percent difference in the proportions of Ag present in each of the coins is no more than 5.5%.

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... Therapy November 8 is the International Day of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  17. Special relativistic effects on the strength of the fluorescent $K\\alpha$ iron line from black hole accretion disks

    CERN Document Server

    Reynolds, C S

    1997-01-01

    The broad iron K$\\alpha$ emission line, commonly seen in the X-ray spectrum of Seyfert nuclei, is thought to originate when the inner accretion disk is illuminated by an active disk-corona. We show that relative motion between the disk and the X-ray emitting material can have an important influence on the observed equivalent width (EW) of this line via special relativistic aberration and Doppler effects. We suggest this may be relevant to understanding why the observed EW often exceeds the prediction of the standard X-ray reflection model. Several observational tests are suggested that could disentangle these special relativistic effects from iron abundance effects.

  18. X-Ray Astronomy

    Science.gov (United States)

    Wu, S. T.

    2000-01-01

    Dr. S. N. Zhang has lead a seven member group (Dr. Yuxin Feng, Mr. XuejunSun, Mr. Yongzhong Chen, Mr. Jun Lin, Mr. Yangsen Yao, and Ms. Xiaoling Zhang). This group has carried out the following activities: continued data analysis from space astrophysical missions CGRO, RXTE, ASCA and Chandra. Significant scientific results have been produced as results of their work. They discovered the three-layered accretion disk structure around black holes in X-ray binaries; their paper on this discovery is to appear in the prestigious Science magazine. They have also developed a new method for energy spectral analysis of black hole X-ray binaries; four papers on this topics were presented at the most recent Atlanta AAS meeting. They have also carried Monte-Carlo simulations of X-ray detectors, in support to the hardware development efforts at Marshall Space Flight Center (MSFC). These computation-intensive simulations have been carried out entirely on the computers at UAH. They have also carried out extensive simulations for astrophysical applications, taking advantage of the Monte-Carlo simulation codes developed previously at MSFC and further improved at UAH for detector simulations. One refereed paper and one contribution to conference proceedings have been resulted from this effort.

  19. X-ray lithography masking

    Science.gov (United States)

    Smith, Henry I. (Inventor); Lim, Michael (Inventor); Carter, James (Inventor); Schattenburg, Mark (Inventor)

    1998-01-01

    X-ray masking apparatus includes a frame having a supporting rim surrounding an x-ray transparent region, a thin membrane of hard inorganic x-ray transparent material attached at its periphery to the supporting rim covering the x-ray transparent region and a layer of x-ray opaque material on the thin membrane inside the x-ray transparent region arranged in a pattern to selectively transmit x-ray energy entering the x-ray transparent region through the membrane to a predetermined image plane separated from the layer by the thin membrane. A method of making the masking apparatus includes depositing back and front layers of hard inorganic x-ray transparent material on front and back surfaces of a substrate, depositing back and front layers of reinforcing material on the back and front layers, respectively, of the hard inorganic x-ray transparent material, removing the material including at least a portion of the substrate and the back layers of an inside region adjacent to the front layer of hard inorganic x-ray transparent material, removing a portion of the front layer of reinforcing material opposite the inside region to expose the surface of the front layer of hard inorganic x-ray transparent material separated from the inside region by the latter front layer, and depositing a layer of x-ray opaque material on the surface of the latter front layer adjacent to the inside region.

  20. CCD sensors in synchrotron X-ray detectors

    Science.gov (United States)

    Strauss, M. G.; Naday, I.; Sherman, I. S.; Kraimer, M. R.; Westbrook, E. M.; Zaluzec, N. J.

    1988-04-01

    The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron X-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction patterns of 100 cm 2 can be imaged on a 2 cm 2 CCD. With a conversion efficiency of ˜ 1 CCD electron/X-ray photon, a peak saturation capacity of > 10 6 X-rays can be obtained. A programmable CCD controller operating at a clock frequency of 20 MHz has been developed. The readout rate is 5 × 10 6 pixels/s and the shift rate in the parallel registers is 10 6 lines/s. The test detector was evaluated in two experiments. In protein crystallography diffraction patterns have been obtained from a lysozyme crystal using a conventional rotating anode X-ray generator. Based on these results we expect to obtain at a synchrotron diffraction images at a rate of ˜ 1 frame/s or a complete 3-dimensional data set from a single crystal in ˜ 2 min. In electron energy-loss spectroscopy (EELS), the CCD was used in a parallel detection mode which is similar to the mode array detectors are used in dispersive EXAFS. With a beam current corresponding to 3 × 10 9 electron/s on the detector, a series of 64 spectra were recorded on the CCD in a continuous sequence without interruption due to readout. The frame-to-frame pixel signal fluctuations had σ = 0.4% from which DQE = 0.4 was obtained, where the detector conversion efficiency was 2.6 CCD electrons/X-ray photon. These multiple frame series also showed the time-resolved modulation of the electron microscope optics by stray magnetic fields.

  1. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a ... Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  4. Soft X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seely, John

    1999-05-20

    The contents of this report cover the following: (1) design of the soft x-ray telescope; (2) fabrication and characterization of the soft x-ray telescope; and (3) experimental implementation at the OMEGA laser facility.

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  6. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses ... assess trauma patients in emergency departments. A CT scan can image complicated fractures, subtle fractures or dislocations. ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  11. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small dose ... to produce pictures of the inside of the abdominal cavity. It is used to evaluate the stomach, liver, ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... radiation like light or radio waves. X-rays pass through most objects, including the body. Once it ... organs, allow more of the x-rays to pass through them. As a result, bones appear white ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations ... patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... and Media Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to X-ray ( ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  17. X-Ray Emitting-Absorbing Media in Seyfert 1 Galaxies

    CERN Document Server

    Mouchet, M; Porquet, D; Dumont, A M; Collin, S

    2000-01-01

    Seyfert galaxies have been shown to exhibit a large variety of features in their X-ray spectra from which the environment of the central engine can be deduced. We focus on the two following aspects: the Warm Absorber, mainly responsible of the soft X-ray properties, and the reprocessing/reflecting plasma medium at the origin of the iron Kalpha fluorescent line. The physical parameters and the location of the so-called Warm Absorber (WA), a photoionized medium along the line of sight to the nuclear region, are more strongly constrained by optical coronal lines than by the oxygen edges observed in the soft X-rays and produced by the WA. The photoionization models also predict the intensities of the X-ray emission lines which are going to be detected with the new generation of X-ray satellites. An alternative model to the relativistic accretion disc is proposed to explain the profile of the X-ray iron Kalpha line observed in the Seyfert 1. This line can be formed in the framework of a quasi-spherical accretion o...

  18. NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    CERN Document Server

    Mori, Kaya; Krivonos, Roman; Hong, Jaesub; Ponti, Gabriele; Bauer, Franz; Perez, Kerstin; Nynka, Melania; Zhang, Shuo; Tomsick, John A; Alexander, David M; Baganoff, Frederick K; Barret, Didier; Barriere, Nicolas; Boggs, Steven E; Canipe, Alicia M; Christensen, Finn E; Craig, William W; Forster, Karl; Giommi, Paolo; Grefenstette, Brian W; Grindlay, Jonathan E; Harrison, Fiona A; Hornstrup, Allan; Kitaguchi, Takao; Koglin, Jason E; Luu, Vy; Madsen, Kristen K; Mao, Peter H; Miyasaka, Hiromasa; Perri, Matteo; Pivovaroff, Michael J; Puccetti, Simonetta; Rana, Vikram; Stern, Daniel; Westergaard, Niels J; Zhang, William W; Zoglauer, Andreas

    2015-01-01

    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with $\\Gamma\\sim1.3$-$2.3$ up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K$\\alpha$ fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density ($\\sim10^{23}$ cm$^{-2}$), primary X-ray spectra (power-laws wi...

  19. X-Ray Exam: Hip

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Hip KidsHealth > For Parents > X-Ray Exam: Hip A A A What's in ... español Radiografía: cadera What It Is A hip X-ray is a safe and painless test that ...

  20. X-Ray Exam: Finger

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Finger KidsHealth > For Parents > X-Ray Exam: Finger A A A What's in ... español Radiografía: dedo What It Is A finger X-ray is a safe and painless test that ...

  1. X-Ray Exam: Foot

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Foot KidsHealth > For Parents > X-Ray Exam: Foot A A A What's in ... español Radiografía: pie What It Is A foot X-ray is a safe and painless test that ...

  2. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Wrist KidsHealth > For Parents > X-Ray Exam: Wrist A A A What's in ... español Radiografía: muñeca What It Is A wrist X-ray is a safe and painless test that ...

  3. X-Ray Exam: Ankle

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Ankle KidsHealth > For Parents > X-Ray Exam: Ankle A A A What's in ... español Radiografía: tobillo What It Is An ankle X-ray is a safe and painless test that ...

  4. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Pelvis KidsHealth > For Parents > X-Ray Exam: Pelvis A A A What's in ... español Radiografía: pelvis What It Is A pelvis X-ray is a safe and painless test that ...

  5. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Forearm KidsHealth > For Parents > X-Ray Exam: Forearm A A A What's in ... español Radiografía: brazo What It Is A forearm X-ray is a safe and painless test that ...

  6. X-ray selected BALQSOs

    CERN Document Server

    Page, M J; Ceballos, M; Corral, A; Ebrero, J; Esquej, P; Krumpe, M; Mateos, S; Rosen, S; Schwope, A; Streblyanska, A; Symeonidis, M; Tedds, J A; Watson, M G

    2016-01-01

    We study a sample of six X-ray selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM-Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index alpha=0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, alpha_OX, of the X-ray selected BALQSOs, have a mean value of 1.69 +- 0.05, which is similar to that found for X-ray selected and optically selected non-BAL QSOs of similar ultraviolet luminosity. In contrast, optically-selected BALQSOs typically have much larger alpha_OX and so are characterised as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray sp...

  7. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  8. SMM x ray polychromator

    Science.gov (United States)

    Saba, J. L. R.

    1993-01-01

    The objective of the X-ray Polychromator (XRP) experiment was to study the physical properties of solar flare plasma and its relation to the parent active region to understand better the flare mechanism and related solar activity. Observations were made to determine the temperature, density, and dynamic structure of the pre-flare and flare plasma as a function of wavelength, space and time, the extent to which the flare plasma departs from thermal equilibrium, and the variation of this departure with time. The experiment also determines the temperature and density structure of active regions and flare-induced changes in the regions.

  9. X-ray today

    Energy Technology Data Exchange (ETDEWEB)

    Neitzel, U. [Philips Medical Systems, Hamburg (Germany)

    2001-09-01

    The interest attracted by the new imaging modalities tends to overshadow the continuing importance of projection radiography and fluoroscopy. Nevertheless, projection techniques still represent by far the greatest proportion of diagnostic imaging examinations, and play an essential role in the growing number of advanced interventional procedures. This article describes some of the latest developments in X-ray imaging technology, using two products from the Philips range as examples: the Integris Allura cardiovascular system with 3D image reconstruction, and the BV Pulsera: a high-end, multi-functional mobile C-arm system with cardiac capabilities. (orig.)

  10. X-ray lithography source

    Science.gov (United States)

    Piestrup, Melvin A.; Boyers, David G.; Pincus, Cary

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  11. Report on a round-robin study of diffuse X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ohshima, K.; Harada, J.; Morinaga, M.; Georgopoulos, P.; Cohen, J.B.

    1986-06-01

    The diffuse scattering in a volume in reciprocal space from NbCsub(0.72) was measured on an absolute scale at two synchrotron sources (in the US and in Japan) and with a high-intensity rotating-anode source (in Japan). The shape and actual absolute intensities agreed to a few percent. Special problems associated with such measurements at a synchrotron are noted, especially with an insertion device. The high resolution possible at such sources reduces the need for an evacuated sample chamber. Detailed measurements can be completed in 1-2 d, making such studies much more accessible than is possible with sealed-tube X-ray generation.

  12. First Results from a Microfocus X-Ray System for Macromolecular Crystallography

    Science.gov (United States)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Gibson, Walter; Joy, Marshall

    1999-01-01

    The design and performance of a 40 Watt laboratory crystallography system optimized for the structure determination of small protein crystals are described. This system combines a microfocus x-ray generator (40 microns FWHM spot size at a power level of 40 Watts) and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small diameter quasi-parallel x-ray beam. Measurements of x-ray flux, divergence and spectral purity of the resulting x-ray beam are presented. The x-ray flux in a 250 microns diameter aperture produced by the microfocus system is 14.7 times higher .than that from a 3.15 kW rotating anode generator equipped with graphite monochromator. Crystallography data taken with the microfocus system are presented, and indicate that the divergence and spectral purity of the x-ray are sufficient to refine the diffraction data using a standard crystallographic software. Significant additional improvements in flux and beam divergence are possible, and plans for achieving these coals are discussed.

  13. Dissecting X-ray-emitting Gas around the Center of our Galaxy

    CERN Document Server

    Wang, Q D; Markoff, S B; Baganoff, F K; Nayakshin, S; Yuan, F; Cuadra, J; Davis, J; Dexter, J; Fabian, A C; Grosso, N; Haggard, D; Houck, J; Ji, L; Li, Z; Neilsen, J; Porquet, D; Ripple, F; Shcherbakov, R V

    2013-01-01

    Most supermassive black holes (SMBHs) are accreting at very low levels and are difficult to distinguish from the galaxy centers where they reside. Our own Galaxy's SMBH provides a uniquely instructive exception, and we present a close-up view of its quiescent X-ray emission based on 3 mega-second of Chandra observations. Although the X-ray emission is elongated and aligns well with a surrounding disk of massive stars, we can rule out a concentration of low-mass coronally active stars as the origin of the emission based on the lack of predicted Fe Kalpha emission. The extremely weak H-like Fe Kalpha line further suggests the presence of an outflow from the accretion flow onto the SMBH. These results provide important constraints for models of the prevalent radiatively inefficient accretion state.

  14. X-ray fluorescent lines from the Compton-thick AGN in M5

    CERN Document Server

    Xu, Weiwei; Gou, Lijun; Liu, Jiren

    2015-01-01

    The cold disk/torus gas surrounding AGN emits fluorescent lines when irradiated by hard X-ray photons. The fluorescent lines of elements other than Fe and Ni are rarely detected due to their relative faintness. We report the detection of K$\\alpha$ lines of neutral Si, S, Ar, Ca, Cr, and Mn, along with the prominent Fe K$\\alpha$, Fe K$\\beta$, and Ni K$\\alpha$ lines, from the deep Chandra observation of the low-luminosity Compton-thick AGN in M51. The Si K$\\alpha$ line at 1.74 keV is detected at $\\sim3\\sigma$, the other fluorescent lines have a significance between 2 and 2.5 $\\sigma$, while the Cr line has a significance of $\\sim1.5\\sigma$. These faint fluorescent lines are made observable due to the heavy obscuration of the intrinsic spectrum of M51, which is revealed by Nustar observation above 10 keV. The hard X-ray continuum of M51 from Chandra and Nustar can be fitted with a power-law spectrum with an index of 1.8, reprocessed by a torus with an equatorial column density of $N_{\\rm H}\\sim7\\times10^{24}$ cm...

  15. X-ray spectral and temporal analysis of Narrow Line Seyfert 1 galaxy Was 61

    CERN Document Server

    Dou, Liming; Ai, Yanli; Yuan, Weimin; Zhou, Hongyan; Dong, Xiao-Bo

    2016-01-01

    We present an analysis of spectrum and variability of the bright reddened narrow line Seyfert 1 galaxy Was~61 using 90 ks archival {\\it XMM-Newton} data. The X-ray spectrum in 0.2-10 keV can be characterized by an absorbed power-law plus soft excess and an Fe K$\\alpha$ emission line. The power-law spectral index remains constant during the flux variation. The absorbing material is mildly ionized, with a column density of 3.2$\\times$10$^{21}$ cm$^{-2}$, and does not appear to vary during the period of the X-ray observation. If the same material causes the optical reddening (E(B-V)$\\simeq$0.6 mag), it must be located outside the narrow line region with a dust-to-gas ratio similar to the average Galactic value. We detect significant variations of the Fe K$\\alpha$ line during the observational period. A broad Fe K$\\alpha$ line at $\\simeq$6.7 keV with a width of $\\sim$0.6 keV is detected in the low flux segment of the first 40 ks exposure, and is absent in the spectra of other segments; a narrow Fe K$\\alpha$ emiss...

  16. Feasibility study of total reflection X-ray fluorescence analysis using a liquid metal jet X-ray tube

    Energy Technology Data Exchange (ETDEWEB)

    Maderitsch, A.; Smolek, S. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria); Wobrauschek, P., E-mail: wobi@ati.ac.at [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria); Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria); Takman, P. [Excillum AB, Finlandsgatan 14, 164 74 Kista (Sweden)

    2014-09-01

    Total reflection X-ray spectroscopy (TXRF) is a powerful analytical technique for qualitative and quantitative analysis of trace and ultratrace elements in a sample with lower limits of detection (LLDs) of pg/g to ng/g in concentration and absolute high fg levels are attainable. Several X-ray sources, from low power (few W), 18 kW rotating anodes to synchrotron radiation, are in use for the excitation and lead accordingly to their photon flux delivered on the sample the detection limits specified. Not only the power, but also the brilliance and focal shape are of importance for TXRF. A microfocus of 50–100 μm spot size or the line focus of diffraction tubes is best suited. Excillum developed a new approach in the design of a source: the liquid metal jet anode. In this paper the results achieved with this source are described. A versatile TXRF spectrometer with vacuum chamber designed at Atominstitut was used for the experiments. A multilayer monochromator selecting the intensive Ga-Kα radiation was taken and the beam was collimated by 50 μm slits. Excellent results regarding geometric beam stability, high fluorescence intensities and low background were achieved leading to detection limits in the high fg range for Ni. A 100 mm{sup 2} silicon drift detector (SDD) collimated to 80 mm{sup 2} was used to collect the fluorescence radiation. The results from measurements on single element samples are presented. - Highlights: • Using a new X-ray source for TXRF • Liquid metal jet X-ray source from Excillum • Offers improvements for lab based TXRF spectrometers • Can also be important for related techniques.

  17. Closed-bore XMR (CBXMR) systems for aortic valve replacement: X-ray tube imaging performance

    Energy Technology Data Exchange (ETDEWEB)

    Bracken, John A.; Komljenovic, Philip; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A. [Department of Medical Biophysics and Sunnybrook Health Sciences Center, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Medical Biophysics and Sunnybrook Health Sciences Center, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada)

    2009-04-15

    A hybrid closed-bore x-ray/MRI system (CBXMR) is proposed to improve the safety and efficacy of percutaneous aortic valve replacement procedures. In this system, an x-ray C-arm will be positioned about 1 m from the entrance of a 1.5 T MRI scanner. The CBXMR system will harness the complementary strengths of both modalities to guide and deploy a bioprosthetic valve into the aortic annulus of the heart without coronary artery obstruction. A major challenge in constructing this system is ensuring proper operation of a rotating-anode x-ray tube in the MRI magnetic fringe field environment. The electron beam in the x-ray tube responsible for producing x rays can be deflected by the fringe field. However, the clinical impact of electron beam deflection in a magnetic field has not yet been studied. Here, the authors investigated changes in focal spot resolving power, field of view shift, and field of view truncation in x-ray images as a result of electron beam deflection. The authors found that in the fringe field acting on the x-ray tube at the clinical location for the x-ray C-arm (4 mT), focal spot size increased by only 2%, so the fringe field did not limit the resolving power of the x-ray system. The magnetic field also caused the field of view to shift by 3 mm. This shift must be corrected to avoid unnecessary primary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. The fringe field was too weak to cause field of view truncation.

  18. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  19. X-ray instrumentation for SR beamlines

    CERN Document Server

    Kovalchuk, M V; Zheludeva, S I; Aleshko-Ozhevsky, O P; Arutynyan, E H; Kheiker, D M; Kreines, A Y; Lider, V V; Pashaev, E M; Shilina, N Y; Shishkov, V A

    2000-01-01

    The main possibilities and parameters of experimental X-ray stations are presented: 'Protein crystallography', 'X-ray structure analysis', 'High-precision X-ray optics', 'X-ray crystallography and material science', 'X-ray topography', 'Photoelectron X-ray standing wave' that are being installed at Kurchatov SR source by A.V. Shubnikov Institute of Crystallography.

  20. X-ray Fluorescence Sectioning

    CERN Document Server

    Cong, Wenxiang

    2012-01-01

    In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental mapping. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be ad...

  1. Soft X-ray optics

    CERN Document Server

    Spiller, Eberhard A

    1993-01-01

    This text describes optics mainly in the 10 to 500 angstrom wavelength region. These wavelengths are 50 to 100 times shorter than those for visible light and 50 to 100 times longer than the wavelengths of medical x rays or x-ray diffraction from natural crystals. There have been substantial advances during the last 20 years, which one can see as an extension of optical technology to shorter wavelengths or as an extension of x-ray diffraction to longer wavelengths. Artificial diffracting structures like zone plates and multilayer mirrors are replacing the natural crystals of x-ray diffraction.

  2. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  3. Fe K$\\alpha$ Profiles from Simulations of Accreting Black Holes

    CERN Document Server

    Kinch, Brooks E; Kallman, Timothy R; Krolik, Julian H

    2016-01-01

    We present first results from a new technique for the prediction of Fe K$\\alpha$ profiles directly from general relativistic magnetohydrodynamic (GRMHD) simulations. Data from a GRMHD simulation are processed by a Monte Carlo global radiation transport code, which determines the X-ray flux irradiating the disk surface and the coronal electron temperature self-consistently. With that irradiating flux and the disk's density structure drawn from the simulation, we determine the reprocessed Fe K$\\alpha$ emission from photoionization equilibrium and solution of the radiation transfer equation. We produce maps of the surface brightness of Fe K$\\alpha$ emission over the disk surface, which---for our example of a $10 M_\\odot$, Schwarzschild black hole accreting at $1\\%$ the Eddington value---rises steeply one gravitational radius outside the radius of the innermost stable circular orbit and then falls $\\propto r^{-2}$ at larger radii. We explain these features of the Fe K$\\alpha$ radial surface brightness profile as ...

  4. Mapping the Ionization State of Laser-Irradiated Ar Gas Jets With Multi-Wavelength Monochromatic X-Ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kugland, N L; Doppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

    2010-04-08

    Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultra-high intensity (10{sup 19} W/cm{sup 2}, 200 fs) Ti:Sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {micro}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {micro}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry, which images in one dimension, indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {micro}m along the laser axis.

  5. No Signatures of Black-Hole Spin in the X-ray Spectrum of the Seyfert 1 Galaxy Fairall 9

    CERN Document Server

    Yaqoob, Tahir; Tatum, Malachi M; Trevor, Max; Scholtes, Alexis

    2016-01-01

    Fairall 9 is one of several type 1 active galactic nuclei for which it has been claimed that the angular momentum (or spin) of the supermassive black hole can be robustly measured, using the Fe K$\\alpha$ emission line and Compton-reflection continuum in the X-ray spectrum. The method rests upon the interpretation of the Fe K$\\alpha$ line profile and associated Compton-reflection continuum in terms of relativistic broadening in the strong gravity regime in the innermost regions of an accretion disc, within a few gravitational radii of the black hole. Here, we re-examine a Suzaku X-ray spectrum of Fairall 9 and show that a face-on toroidal X-ray reprocessor model involving only nonrelativistic and mundane physics provides an excellent fit to the data. The Fe K$\\alpha$ line emission and Compton reflection continuum are calculated self-consistently, the iron abundance is solar, and an equatorial column density of $\\sim 10^{24} \\ \\rm cm^{-2}$ is inferred. In this scenario, neither the Fe K$\\alpha$ line, nor the Co...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone absorbs much of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x-rays to pass through them. As a result, bones appear white on the x-ray, soft tissue shows up in shades of gray and air ...

  8. Slow scan sit detector for x-ray diffraction studies using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Milch, J R

    1978-10-18

    A TV-type x-ray detector using a SIT vidicon has been used for biological diffraction studies at the EMBL outstation at DESY, Hamburg, Germany. The detector converts the two-dimensional diffraction pattern to a charge pattern on the vidicon target, which is read out in the slow-scan mode. This detector has high DOE, no count-rate limit, and is simple and inexpensive to construct. Radiation from the storage ring DORIS was used to study the structure of live muscle at various phases of contraction. Typically the count-rate on the detector was 10/sup 6/ x-rays/sec and a total exposure of a few seconds was needed to record the weak diffraction from muscle. This compares with usual exposure times of several hours using a rotating anode generator and film.

  9. Focusing X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen; Brissenden, Roger; Davis, William; Elsner, Ronald; Elvis, Martin; Freeman, Mark; Gaetz, Terrance; Gorenstein, Paul; Gubarev, Mikhall; Jerlus, Diab; Juda, Michael; Kolodziejczak, Jeffrey; Murray, Stephen; Petre, Robert; Podgorski, William; Ramsey, Brian; Reid, Paul; Saha, Timo; Wolk, Scott; Troller-McKinstry, Susan; Weisskopf, Martin; Wilke, Rudeger; Zhang, William

    2010-01-01

    During the half-century history of x-ray astronomy, focusing x-ray telescopes, through increased effective area and finer angular resolution, have improved sensitivity by 8 orders of magnitude. Here, we review previous and current x-ray-telescope missions. Next, we describe the planned next-generation x-ray-astronomy facility, the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility, Generation X. Its scientific objectives will require very large areas (about 10,000 sq m) of highly-nested, lightweight grazing-incidence mirrors, with exceptional (about 0.1-arcsec) resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

  10. X-Ray Tomographic Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bonnie Schmittberger

    2010-08-25

    Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

  11. X-Ray Diffraction Apparatus

    Science.gov (United States)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  12. Relativistic Iron Line Emission from the Neutron Star Low-mass X-ray Binary 4U 1636-536

    OpenAIRE

    Pandel, Dirk; Kaaret, Philip; Corbel, Stephane

    2008-01-01

    We present an analysis of XMM-Newton and RXTE data from three observations of the neutron star LMXB 4U 1636-536. The X-ray spectra show clear evidence of a broad, asymmetric iron emission line extending over the energy range 4-9 keV. The line profile is consistent with relativistically broadened Fe K-alpha emission from the inner accretion disk. The Fe K-alpha line in 4U 1636-536 is considerably broader than the asymmetric iron lines recently found in other neutron star LMXBs, which indicates...

  13. X-ray monitoring optical elements

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav; Shvydko, Yury; Katsoudas, John; Blank, Vladimir D.; Terentyev, Sergey A.

    2016-12-27

    An X-ray article and method for analyzing hard X-rays which have interacted with a test system. The X-ray article is operative to diffract or otherwise process X-rays from an input X-ray beam which have interacted with the test system and at the same time provide an electrical circuit adapted to collect photoelectrons emitted from an X-ray optical element of the X-ray article to analyze features of the test system.

  14. X-ray diagnostics for TFTR

    Energy Technology Data Exchange (ETDEWEB)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment.

  15. Probing the Galactic center with X-ray polarimetry

    CERN Document Server

    Marin, F; Kunneriath, D; Muleri, F; Soffitta, P

    2014-01-01

    The Galactic center (GC) holds the closest-to-Earth supermassive black hole (SMBH), which makes it the best laboratory to study the close environment of extremely massive compact objects. Polarimetry is sensitive to geometry of the source, which makes it a particularly suitable technique to probe the medium surrounding the GC SMBH. The detection of hard X-ray spectra and prominent iron K$\\alpha$ fluorescence features coincident with localized gas clouds (e.g. Sgr~B2, Sgr~C) is known for nearly twenty years now and is commonly associated with a past outburst of the SMBH whose radiation is reprocessing onto the so-called "reflection nebulae". Since scattering leads to polarization, the re-emitted signal from the giant molecular clouds in the first 100~pc of the GC is expected to be polarized. X-ray polarization measurement is thus particularly adapted to probe the origin of the diffuse X-ray emission from the GC reflection nebulae and reveal the past activity of the central SMBH. In this research note, we summa...

  16. \\gamma Cassiopeiae: an X-ray Be star with personality

    CERN Document Server

    de Oliveira, Raimundo Lopes; Motch, Christian; ;,

    2009-01-01

    \\gamma Cas is a B0.5e star with peculiar X-ray emission properties and yet the prototype of its own small class. In this paper we examine the X-ray spectra for a 2004 XMM-Newton observation and a previously published 2001 Chandra observation. In both cases the spectra can be modeled with 3 or 4 thermal components, which appear be discrete in temperature and spatially distinct. The dominant component, having kT ~ 12 keV contributes most of the flux. The secondary components have temperatures in the range of 2-3 keV to 0.1 keV; these values can shift in time. Importantly, we find that the strong absorption of soft X-rays in 2001 is absent in 2004, meaning that an absorbing column in front of the source has moved off the star or has been removed. Other differences include a reduced Fe abundance from the ionized lines of the FeKalpha complex (even more subsolar than the 2001 observation), an increase in the Fe K fluoresence feature, and from the NVII and NeX H-alpha lines, a possible overabundance of N and Ne. Al...

  17. X-ray reflectometer for single layer and multilayer coating characterization at 8 keV: An interlaboratory study

    Science.gov (United States)

    Gurgew, Danielle N.; Broadway, David M.; Gubarev, Mikhail; Ramsey, Brian D.; Gregory, Don A.

    2016-10-01

    An X-ray reflectometer (XRR) system has been developed at the Marshall Space Flight Center (MSFC) for characterizing various soft and hard X-ray optic coatings. The XRR instrument generates X-ray radiation using a high-output rotating anode source (RAS), operational over a voltage range of 5-35 kV and a current range of 10-150 mA. Copper is used as the target material to produce an X-ray spectrum from which the Kα line at 8.048 keV is isolated for the reflectivity measurements. Five precision slits are mounted along the X-ray beam path to limit the extent of the beam at the sample and to adjust the resolution in the measurements. A goniometer consisting of two precision rotary stages controls the positions of the coating sample and the X-ray detector with respect to the beam. The detector itself is a high performance silicon drift detector used to achieve high count rate efficiency to attain good statistics in the reflectivity measurement at larger grazing angles. The X-ray reflectometer system design and capabilities are described in detail. Verification of the system is obtained through an interlaboratory study in which reflectivity measurements of a multilayer coating made at MSFC are compared with those made at two external laboratories.

  18. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  20. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... bony fragments following treatment of a fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement ... A portable x-ray machine is a compact apparatus that can be taken to the patient in ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  4. CELESTIAL X-RAY SOURCES.

    Science.gov (United States)

    sources, (4) the physical conditions in the pulsating x-ray source in the Crab Nebula , and (5) miscellaneous related topics. A bibliography of all work performed under the contract is given. (Author)

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... asked to wait until the radiologist determines that all the necessary images have been obtained. A bone ... while it may be barely seen, if at all, on a hip x-ray. For suspected spine ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... diagnosis and treatment of the individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing ...

  7. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ... individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing radiation to create diagnostic images, ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are easily accessible and are frequently compared to current x-ray images for diagnosis and disease management. ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose ... bone x-ray makes images of any bone in the body, including the hand, wrist, arm, elbow, ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... 06, 2016 Send us your feedback Did you find the information you were looking for? Yes No ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray images were maintained on large film sheets (much like a large photographic negative). Today, most ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ... so that any change in a known abnormality can be monitored over time. Follow-up examinations are ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... code: Phone no: Thank you! Do you have a personal story about radiology? Share your patient story ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  1. Soft X-ray emission studies of biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Kurmaev, E.Z. E-mail: kurmaev@ifmlrs.uran.ru; Werner, J.P.; Moewes, A.; Chiuzbaian, S.; Bach, M.; Ching, W.-Y.; Motozaki, W.; Otsuka, T.; Matsuya, S.; Endo, K.; Neumann, M

    2004-07-01

    Soft X-ray fluorescence measurements are used to characterize three groups of biomaterials: Vitamin B{sub 12} and derivatives, antioxidants (aspirin and paracetamol), and human teeth. We show that the chemical bonding in Vitamin B{sub 12} is characterized by the strong Co-C bond and the relatively weak Co-N bond. The Co-C bond in cyanocobalamin is found to be stronger than that of methylcobalamin leading to their different biological activity. The chemical bonding of paracetamol and aspirin is characterized by the formation of oxygen lone-pair {pi}-orbitals, which can neutralize free radicals and therefore be related to antioxidant activity of these compounds. Carbon K{alpha} emission spectra of a caries lesion suggest that the CaCO{sub 3} like phase exists in sound enamel and that a selective loss of carbonate occurs during the early stages of a caries attack.

  2. Electromechanical x-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Scott A; Platts, David; Sorensen, Eric B

    2016-05-03

    An electro-mechanical x-ray generator configured to obtain high-energy operation with favorable energy-weight scaling. The electro-mechanical x-ray generator may include a pair of capacitor plates. The capacitor plates may be charged to a predefined voltage and may be separated to generate higher voltages on the order of hundreds of kV in the AK gap. The high voltage may be generated in a vacuum tube.

  3. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  4. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  5. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    these published reports. There were two main types of X-ray detection methods: “indirect,” which uses a scintillation material coupled to a light...Reference 3), inorganic semiconductors (silicon [Si], cadmium zinc telluride [CdZnTe]) (Reference 4) and selenium (References 5 and 6), Ne-Xe...metal-oxide semiconductor field-effect transistor (MOSFET) X-ray dosimeters (Reference 24). Electrets may be charged by a range of methods

  6. X-ray laser; Roentgenlaser

    Energy Technology Data Exchange (ETDEWEB)

    Samuelsen, Emil J.; Breiby, Dag W.

    2009-07-01

    X-ray is among the most important research tools today, and has given priceless contributions to all disciplines within the natural sciences. State of the art in this field is called XFEL, X-ray Free Electron Laser, which may be 10 thousand million times stronger than the x-rays at the European Synchrotron Radiation Facility in Grenoble. In addition XFEL has properties that allow the study of processes which previously would have been impossible. Of special interest are depictions on atomic- and molecular level by the use of x-ray holographic methods, and being able to study chemical reactions in nature's own timescale, the femtosecond. Conclusion: The construction of x-ray lasers is a natural development in a scientific field which has an enormous influence on the surrounding society. While the discovery of x-ray was an important breakthrough in itself, new applications appear one after the other: Medical depiction, dissemination, diffraction, DNA and protein structures, synchrotron radiation and tomography. There is reason to believe that XFEL implies a technological leap as big as the synchrotrons some decades ago. As we are now talking about studies of femtosecond and direct depiction of chemical reactions, it is obvious that we are dealing with a revolution to come, with extensive consequences, both scientifically and culturally. (EW)

  7. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most ...

  8. X-ray reflected spectra from accretion disk models.II. Diagnostic tools for X-ray observations

    CERN Document Server

    Garcia, J; Mushotzky, R F

    2011-01-01

    We present a comprehensive study of the emission spectra from accreting sources. We use our new reflection code to compute the reflected spectra from an accretion disk illuminated by X-rays. This set of models covers different values of ionization parameter, solar iron abundance and photon index for the illuminating spectrum. These models also include the most complete and recent atomic data for the inner-shell of the iron and oxygen isonuclear sequences. We concentrate our analysis to the 2-10 keV energy region, and in particular to the iron K-shell emission lines. We show the dependency of the equivalent width (EW) of the Fe K$\\alpha$ with the ionization parameter. The maximum value of the EW is $\\sim 800$ eV for models with log $\\xi\\sim 1.5$, and decreases monotonically as $\\xi$ increases. For lower values of $\\xi$ the Fe K$\\alpha$ EW decreases to a minimum near log $\\xi\\sim 0.8$. We produce simulated CCD observations based on our reflection models. For low ionized, reflection dominated cases, the 2-10 keV...

  9. [Determination of 22 Elements in Herb Tea by X-Ray Fluorescence Spectrometry].

    Science.gov (United States)

    Li, Dan; Ge, Liang-quan; Wang, Guang-xi; Lai, Wan-chang; Zhai, Juan; Chen, Lu

    2015-07-01

    N, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb in herb tea were determined by X-ray fluorescence spectrometry with pressed powder pellets. The measuring conditions of target elements were investigated, including how to select its analytical line. In addition to Ba and Pb using L line, Kalpha line was selected for the rest. When the Compton scattered radiation of Rh Kalpha was measured, The X-ray tube voltage should be appropriately reduced, and the appropriate tube current should be selected. The matrix effect was corrected by empirical coefficient method and using scattered radiation (the Rayleigh scattered radiation of Rh Lalpha, the scattered background of 0.1876 nm wavelength position and the Compton scattered radiation of Rh Kalpha) as internal standard, and the spectral overlapping interference of some elements (N, Na, Ca, Ti, Mn, Sr and Ba) was corrected. For the target elements, the detection limit of this method was low, and its accuracy and precision were high. The results showed that there were abandon of elements in herb tea, of which different kinds had different components, even the same kind of herb tea with different source had some difference in element and content more or less, however, there was a lot of similarity between the features of its components. In a word, this method could achieve multi-element determination of herb tea, and it was simple in operation, low cost, rapid, and accurate.

  10. Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

    CERN Document Server

    Wobrauschek, P; Pepponi, G; Bergmann, A; Glatter, O

    2002-01-01

    Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path. The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm sup 2 area. For Co detection limits of about 300 fg determined by a single element standard have been achieved. Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z.

  11. Monochromatic computed tomography with a compact laser-driven X-ray source.

    Science.gov (United States)

    Achterhold, K; Bech, M; Schleede, S; Potdevin, G; Ruth, R; Loewen, R; Pfeiffer, F

    2013-01-01

    A laser-driven electron-storage ring can produce nearly monochromatic, tunable X-rays in the keV energy regime by inverse Compton scattering. The small footprint, relative low cost and excellent beam quality provide the prospect for valuable preclinical use in radiography and tomography. The monochromaticity of the beam prevents beam hardening effects that are a serious problem in quantitative determination of absorption coefficients. These values are important e.g. for osteoporosis risk assessment. Here, we report quantitative computed tomography (CT) measurements using a laser-driven compact electron-storage ring X-ray source. The experimental results obtained for quantitative CT measurements on mass absorption coefficients in a phantom sample are compared to results from a rotating anode X-ray tube generator at various peak voltages. The findings confirm that a laser-driven electron-storage ring X-ray source can indeed yield much higher CT image quality, particularly if quantitative aspects of computed tomographic imaging are considered.

  12. Development of synchrotron radiation as a high-intensity source for X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Huxley, H.E. [Brandeis Univ., Rosenstiel Center, Waltham, Massachusetts (United States); Holmes, K.C. [Max-Planck-Inst. fuer Medizinische Forschung, Heidelberg (Germany)

    1997-11-01

    Interest in the molecular mechanism of muscle contraction led to the search for an intense source of X-rays of 1-2 Aa wavelength so as to be able to examine the rich X-ray diffraction patterns given by muscles during contraction. This led to the first X-ray diffraction experiments using synchrotron radiation, carried out by Holmes, Rosenbaum and Witz at DESY, Hamburg, in September 1970. In the following years, the EMBL Outstation, to utilize synchrotron radiation for biological structure determination, was established at DESY and preliminary experiments on muscle were also carried out at NINA (Daresbury). The development of time-resolved techniques for muscle diffraction was first started in the MRC Molecular Biology Laboratory in Cambridge, using rotating-anode X-ray tubes, and was then greatly extended at the EMBL Outstation, Hamburg, using the storage ring DORIS. This was a very successful venture, and helped to drive the whole technology development and to interest other potential users in the technique. (au).

  13. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  14. X-ray echo spectroscopy

    CERN Document Server

    Shvyd'ko, Yuri

    2015-01-01

    X-ray echo spectroscopy, a counterpart of neutron spin-echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x-rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1--0.02-meV ultra-high-resolution IXS applications (resolving power $> 10^8$) with broadband $\\simeq$~5--13~meV dispersing systems are introduced featuring more than $10^3$ signal e...

  15. X-ray Echo Spectroscopy.

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-26

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >10^{8}) with broadband ≃5-13  meV dispersing systems are introduced featuring more than 10^{3} signal enhancement. The technique is general, applicable in different photon frequency domains.

  16. Chemical Environment Effects on K[beta]/K[alpha] Intensity Ratio: An X-Ray Fluorescence Experiment on Periodic Trends

    Science.gov (United States)

    Durham, Chaney R.; Chase, Jeffery M.; Nivens, Delana A.; Baird, William H.; Padgett, Clifford W.

    2011-01-01

    X-ray fluorescence (XRF) data from an energy-dispersive XRF instrument were used to investigate the chlorine K[alpha] and K[beta] peaks in several group 1 salts. The ratio of the peak intensity is sensitive to the local chemical environment of the chlorine atoms studied in this experiment and it shows a periodic trend for these salts. (Contains 1…

  17. Measurements of Ionic Structure in Shock Compressed Lithium Hydride from Ultra-fast X-ray Thomson Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kritcher, A L; Neumayer, P; Brown, C; Davis, P; Doppner, T; Falcone, R W; Gericke, D O; Gregori, G; Holst, B; Landen, O L; Lee, H J; Morse, E C; Pelka, A; Redmer, R; Roth, M; Vorberger, J; Wunsch, K; Glenzer, S H

    2009-07-14

    We present the first ultrafast temporally, spectrally and angularly resolved x-ray scattering measurements from shock-compressed matter. These laser-compressed lithium-hydride samples are well characterized by inelastic Compton and Plasmon scattering of a K-{alpha} x-ray probe providing independent measurements of temperature and density. The experimental spectra yield the absolute elastic and inelastic scattering intensities from the measured density of free electrons. The data show excellent agreement with the total intensity and structure when using the two-species form factor and accounting for ionic screening.

  18. X-ray imaging: Perovskites target X-ray detection

    Science.gov (United States)

    Heiss, Wolfgang; Brabec, Christoph

    2016-05-01

    Single crystals of perovskites are currently of interest to help fathom fundamental physical parameters limiting the performance of perovskite-based polycrystalline solar cells. Now, such perovskites offer a technology platform for optoelectronic devices, such as cheap and sensitive X-ray detectors.

  19. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  20. X-ray spectropolarimetric measurements of the Kerr metric

    CERN Document Server

    Liu, Dan; Cheng, Yifan; Bambi, Cosimo

    2015-01-01

    It is thought that the spacetime geometry around black hole candidates is described by the Kerr solution, but an observational confirmation is still missing. Today, the continuum-fitting method and the analysis of the iron K$\\alpha$ line cannot unambiguously test the Kerr paradigm because of the degeneracy among the parameters of the system, in the sense that it is impossible with current X-ray data to distinguish a Kerr black hole from a non-Kerr object with different spin and observed from a different viewing angle. In this paper, we study the possibility of testing the Kerr nature of black hole candidates with X-ray spectropolarimetric measurements. As a preliminary study, we employ a model with some simplifications, but our conclusions can unlikely change with a more sophisticated description. We find that -- even in the case of high quality data -- it is impossible to test the Kerr metric and the problem is still the strong correlation between the spin and possible deviations from the Kerr geometry. The ...

  1. Determination of beryllium by using X-ray fluorescence spectrometry.

    Science.gov (United States)

    Zawisza, Beata

    2008-03-01

    X-ray fluorescence spectrometry method is subject to certain difficulties and inconveniences for the elements having the atomic number 9 or less. These difficulties become progressively more severe as the atomic number decreases, and are quite serious for beryllium, which is practically indeterminable directly by XRF. Therefore, an indirect determination of beryllium that is based on the evaluation of cobalt in the precipitate is taken into consideration. In the thesis below, there is a description of a new, simple, and precise method by selective precipitation using hexamminecobalt(III) chloride and ammonium carbonate-EDTA solution as a complexing agent for the determining of a trace amount of beryllium using X-ray fluorescence spectrometry. The optimum conditions for [Co(NH(3))(6)][Be(2)(OH)(3)(CO(3))(2)(H(2)O)(2)].(3)H(2)O complex formation were studied. The complex was collected on the membrane filter, and the Co Kalpha line was measured by XRF. The method presents the advantages of the sample preparation and the elimination of the matrix effects due to the thin film obtained. The detection limit of the proposed method is 0.2 mg of beryllium. The method was successfully applied to beryllium determination in copper/ beryllium/cobalt alloys.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  4. X-rays and magnetism.

    Science.gov (United States)

    Fischer, Peter; Ohldag, Hendrik

    2015-09-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques.

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray ( ... are the fastest and easiest way for your doctor to view and assess bone fractures, injuries and ...

  6. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and places the x-ray film holder or digital recording plate under the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you maintain the ...

  8. Alpha proton x ray spectrometer

    Science.gov (United States)

    Rieder, Rudi; Waeke, H.; Economou, T.

    1994-01-01

    Mars Pathfinder will carry an alpha-proton x ray spectrometer (APX) for the determination of the elemental chemical composition of Martian rocks and soils. The instrument will measure the concentration of all major and some minor elements, including C, N, and O at levels above typically 1 percent.

  9. X-ray backscatter imaging

    Science.gov (United States)

    Dinca, Dan-Cristian; Schubert, Jeffrey R.; Callerame, J.

    2008-04-01

    In contrast to transmission X-ray imaging systems where inspected objects must pass between source and detector, Compton backscatter imaging allows both the illuminating source as well as the X-ray detector to be on the same side of the target object, enabling the inspection to occur rapidly and in a wide variety of space-constrained situations. A Compton backscatter image is similar to a photograph of the contents of a closed container, taken through the container walls, and highlights low atomic number materials such as explosives, drugs, and alcohol, which appear as especially bright objects by virtue of their scattering characteristics. Techniques for producing X-ray images based on Compton scattering will be discussed, along with examples of how these systems are used for both novel security applications and for the detection of contraband materials at ports and borders. Differences between transmission and backscatter images will also be highlighted. In addition, tradeoffs between Compton backscatter image quality and scan speed, effective penetration, and X-ray source specifications will be discussed.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  12. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... dislocations. In elderly or patients with osteoporosis, a hip fracture may be clearly seen on a CT scan, while it may be barely seen, if at all, on a hip x-ray. For suspected spine injury or other ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  15. Development of a Laboratory Micron-Resolution X-ray Microprobe to Map Mineralogy and Trace Elements at PPM Sensitivity for Digital Rock, Magma, and Mining Applications

    Science.gov (United States)

    Yun, W.; Lewis, S.; Stripe, B.; Chen, S.; Reynolds, D.; Spink, I.; Lyon, A.

    2015-12-01

    We are developing a patent-pending x-ray microprobe with substantially unprecedented performance attributes: working distances of >2 cm, narrow spectral bandwidth, and large x-ray flux. The outstanding performance is enabled by: (1) a revolutionary new type of high flux x-ray source designed to be >10X brighter than the brightest rotating anode x-ray source available; (2) an axially symmetric x-ray mirror lens with large solid angle collection and high focusing efficiency; and (3) a detector configuration that enables the collection of 10X more x-rays than current microXRF designs. The sensitivity will be ppm-scale, far surpassing charged particle analysis (e.g. EPMA and SEM-EDS), and >1000X throughput over the leading micro-XRFs. Despite the introduction of a number of laboratory microXRF systems in the past decade, the state-of-the-art has been limited primarily by low resolution (~30 μm) and low throughput. This is substantially attributable to a combination of low x-ray source brightness and poor performance x-ray optics. Here we present our initial results in removing the x-ray source bottleneck, in which we use a novel x-ray source using Fine Anode Array Source Technology (Sigray FAAST™). When coupled with our proprietary high efficiency x-ray mirror lens, the throughput achieved is comparable to that of many synchrotron microXRF beamlines. Potential applications of the x-ray microprobe include high throughput mapping of mineralogy at high resolution, including trace elements, such as rare earth metals, and deposits (e.g. siderite, clays), with ppm sensitivity, providing information for properties such as permeability and elastic/mechanical properties, and to provide compositional information for Digital Rock. Additional applications include those in which the limited penetration of electrons limits achieving adequate statistics, such as determining the concentration of precious minerals in mine tailings.

  16. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    OpenAIRE

    de Groot, F. M. F.

    2001-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption process. Section II discusses 1s X-ray absorption, i.e., the K edges, and section III deals with 2p X-ray absorption, the L edges. X-ray emission is discussed in, respectively, the L edges. X-ray emis...

  17. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  18. X-ray reprocessing in binaries

    Science.gov (United States)

    Paul, Biswajit

    2016-07-01

    We will discuss several aspects of X-ray reprocessing into X-rays or longer wavelength radiation in different kinds of binary systems. In high mass X-ray binaries, reprocessing of hard X-rays into emission lines or lower temperature black body emission is a useful tool to investigate the reprocessing media like the stellar wind, clumpy structures in the wind, accretion disk or accretion stream. In low mass X-ray binaries, reprocessing from the surface of the companion star, the accretion disk, warps and other structures in the accretion disk produce signatures in longer wavelength radiation. X-ray sources with temporal structures like the X-ray pulsars and thermonuclear burst sources are key in such studies. We will discuss results from several new investigations of X-ray reprocessing phenomena in X-ray binaries.

  19. Proof-of-concept development of PXAMS (projectile x-ray accelerator mass spectrometry)

    Energy Technology Data Exchange (ETDEWEB)

    Proctor, I.D.; Roberts, M.L.; McAninch, J.E.; Bench, G.S.

    1996-03-01

    Prior to the current work, accelerator mass spectrometry (AMS) was limited to a set of {approximately}8--10 isotopes. This limitation is caused primarily by the inability to discriminate against stable atomic isobars. An analysis scheme that combines the isotopic sensitivity of AMS with similar isobar selectivity would open a large new class of isotope applications. This project was undertaken to explore the use of characteristic x rays as a method for the detection and identification of ions,and to allow the post-spectrometer rejection of isobaric interferences for isotopes previously inaccessible to AMS. During the second half of FY94 (with Advanced Concepts funding from the Office of Non-Proliferation and National Security), we examined the feasability of this technique, which we are referring to as PXAMS (Projectile X ray AMS), to the detection of several isotopes at Lawrence Livermore National Laboratory (LLNL). In our first exploratory work, we measured the x ray yield vs energy for {sup 80}Se ions stopped in a thick Y target. These results, demonstrated that useful detection efficiencies could be obtained for Se ions at energies accessible with our accelerator, and that the count rate from target x rays is small compared to the Se K{alpha} rate. We followed these measurements with a survey of x ray yields for Z = 14-46.

  20. An XMM-Newton spectral survey of 12 micron selected galaxies. I. X-ray data

    CERN Document Server

    Brightman, Murray

    2010-01-01

    We present an X-ray spectral analysis of 126 galaxies of the 12 micron galaxy sample. We pay particular attention to Compton thick AGN with the help of new spectral fitting models that we have produced, which are based on Monte-Carlo simulations of X-ray radiative transfer, using both a spherical and torus geometry, and taking into account Compton scattering and Fe fluorescence. We use this data to show that with a torus geometry, unobscured sight lines can achieve a maximum EW of the Fe K\\alpha line of ~150 eV, originally shown by Ghisellini, Haardt & Matt (1994). In order for this to be exceeded, the line of sight must be obscured with N_H>10^23 cm^-2, as we show for one case, NGC 3690. We also calculate flux suppression factors from the simulated data, the main conclusion from which is that for N_H>10^25 cm^-2, the X-ray flux is suppressed by a factor of >10 in all X-ray bands and at all redshifts, revealing the biases present against these extremely heavily obscured systems inherent in all X-ray surve...

  1. Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies

    Energy Technology Data Exchange (ETDEWEB)

    Zucchini, F.; Chauvin, C.; Combes, P.; Sol, D.; Loyen, A.; Roques, B.; Grunenwald, J. [CEA, DAM, GRAMAT, F-46500 Gramat (France); Bland, S. N. [Blackett Laboratory, Imperial College, London SW7 2BW (United Kingdom)

    2015-03-15

    X-ray emission from a molybdenum X-pinch has been investigated as a potential probe for the high pressure states made in dynamic compression experiments. Studies were performed on a novel 300 kA, 400 ns generator which coupled the load directly to a low inductance capacitor and switch combination. The X-pinch load consisted of 4 crossed molybdenum wires of 13 μm diameter, crossed at an angle of 62°. The load height was 10 mm. An initial x-ray burst generated at the wire crossing point, radiated in the soft x-ray range (hυ < 10 keV). This was followed, 2–5 ns later, by at least one harder x-ray burst (hυ > 10 keV) whose power ranged from 1 to 7 MW. Time integrated spectral measurements showed that the harder bursts were dominated by K-alpha emission; though, a lower level, wide band continuum up to at least 30 keV was also present. Initial tests demonstrated that the source was capable of driving Laue diffraction experiments, probing uncompressed samples of LiF and aluminium.

  2. Detection limits for actinides in a monochromatic, wavelength-dispersive x-ray fluorescence instrument

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Michael L [Los Alamos National Laboratory; Havrilla, George J [Los Alamos National Laboratory

    2009-01-01

    Recent developments in x-ray optics have made it possible to examine the L x-rays of actinides using doubly-curved crystals in a bench-top device. A doubly-curved crystal (DCC) acts as a focusing monochromatic filter for polychromatic x-rays. A Monochromatic, Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) instrument that uses DCCs to measure Cm and Pu in reprocessing plant liquors was proposed in 2007 by the authors at Los Alamos National Laboratory. A prototype design of this MWDXRF instrument was developed in collaboration with X-ray Optical Systems Inc. (XOS), of East Greenbush, New York. In the MWDXRF instrument, x-rays from a Rhodium-anode x-ray tube are passed through a primary DCC to produce a monochromatic beam of 20.2-keV photons. This beam is focused on a specimen that may contain actinides. The 20.2-keV interrogating beam is just above the L3 edge of Californium; each actinide (with Z = 90 to 98) present in the specimen emits characteristic L x-rays as the result of L3-shell vacancies. In the LANL-XOS prototype MWDXRf, these x-rays enter a secondary DCC optic that preferentially passes 14.961-keV photons, corresponding to the L-alpha-1 x-ray peak of Curium. In the present stage of experimentation, Curium-bearing specimens have not been analyzed with the prototype MWDXRF instrument. Surrogate materials for Curium include Rubidium, which has a K-beta-l x-ray at 14.961 keV, and Yttrium, which has a K-alpha-1 x-ray at 14.958 keV. In this paper, the lower limit of detection for Curium in the LANL-XOS prototype MWDXRF instrument is estimated. The basis for this estimate is described, including a description of computational models and benchmarking techniques used. Detection limits for other actinides are considered, as well as future safeguards applications for MWDXRF instrumentation.

  3. The dust sublimation radius as an outer envelope to the bulk of the narrow Fe Kalpha line emission in Type 1 AGN

    CERN Document Server

    Gandhi, Poshak; Kishimoto, Makoto

    2015-01-01

    The Fe Kalpha emission line is the most ubiquitous feature in the X-ray spectra of active galactic nuclei (AGN), but the origin of its narrow core remains uncertain. Here, we investigate the connection between the sizes of the Fe Kalpha core emission regions and the measured sizes of the dusty tori in 13 local Type 1 AGN. The observed Fe Kalpha emission radii (R_fe) are determined from spectrally resolved line widths in X-ray grating spectra, and the dust sublimation radii (R_dust) are measured either from optical/near-infrared reverberation time lags or from resolved near-infrared interferometric data. This direct comparison shows that the dust sublimation radius forms an outer envelope to the bulk of the Fe Kalpha emission. R_fe matches R_dust well in the AGN with the best constrained line widths currently. In a significant fraction of objects without a clear narrow line core, R_fe is similar to, or smaller than the radius of the optical broad line region. These facts place important constraints on the toru...

  4. X-Ray-powered Macronovae

    Science.gov (United States)

    Kisaka, Shota; Ioka, Kunihito; Nakar, Ehud

    2016-02-01

    A macronova (or kilonova) was observed as an infrared excess several days after the short gamma-ray burst GRB 130603B. Although the r-process radioactivity is widely discussed as an energy source, it requires a huge mass of ejecta from a neutron star (NS) binary merger. We propose a new model in which the X-ray excess gives rise to the simultaneously observed infrared excess via thermal re-emission, and explore what constraints this would place on the mass and velocity of the ejecta. This X-ray-powered model explains both the X-ray and infrared excesses with a single energy source such as the central engine like a black hole, and allows for a broader parameter region than the previous models, in particular a smaller ejecta mass ˜ {10}-3{--}{10}-2{M}⊙ and higher iron abundance mixed as suggested by general relativistic simulations for typical NS-NS mergers. We also discuss the other macronova candidates in GRB 060614 and GRB 080503, and the implications for the search of electromagnetic counterparts to gravitational waves.

  5. Be/X-ray binaries

    CERN Document Server

    Reig, Pablo

    2011-01-01

    The purpose of this work is to review the observational properties of Be/X-ray binaries. The open questions in Be/X-ray binaries include those related to the Be star companion, that is, the so-called "Be phenomenon", such as, timescales associated to the formation and dissipation of the equatorial disc, mass-ejection mechanisms, V/R variability, and rotation rates; those related to the neutron star, such as, mass determination, accretion physics, and spin period evolution; but also, those that result from the interaction of the two constituents, such as, disc truncation and mass transfer. Until recently, it was thought that the Be stars' disc was not significantly affected by the neutron star. In this review, I present the observational evidence accumulated in recent years on the interaction between the circumstellar disc and the compact companion. The most obvious effect is the tidal truncation of the disc. As a result, the equatorial discs in Be/X-ray binaries are smaller and denser than those around isolat...

  6. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  7. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  8. Computerized data collection and reduction from an X-ray diffractometer

    Science.gov (United States)

    Mcclure, J. C.

    1982-01-01

    A series of computer programs written for use with a Philips X-ray diffractometer and a Hewlett Packard 9825A desk top computer is described. These programs permit the collection and storage on disk of the number of x-ray counts and the associated 2-thera angles across line profiles. Automatic background subtraction, integrated intensity, correction for the angular dependance of the Lorentz, polarization, and atomic scattering factors, peak location, K-alpha 2 removal, and calculation of Fourier coefficients are performed. The programs are written for a computer configured with a disk drive, but they can be easily modified to run from the cassette tape drive that is integral to the 9825A computer.

  9. $K$-series X-rays yield measurement of kaonic hydrogen atoms in gaseous target

    CERN Document Server

    Bazzi, M; Bellotti, G; Berucci, C; Bragadireanu, A M; Bosnar, D; Cargnelli, M; Curceanu, C; Butt, A D; d'Uffizi, A; Fiorini, C; Ghio, F; Guaraldo, C; Hayanao, R S; Iliescu, M; Ishiwatari, T; Iwasaki, M; Sandri, P Levi; Marton, J; Okada, S; Pietreanu, D; Piscicchia, K; Vidal, A Romero; Sbardella, E; Scordo, A; Shi, H; Sirghi, D L; Sirghi, F; Tatsuno, H; Doce, O Vazquez; Widmann, E; Zmeskal, J

    2016-01-01

    We measured the $K$-series X-rays of the $K^{-}p$ exotic atom in the SIDDHARTA experiment with a gaseous hydrogen target of 1.3 g/l, which is about 15 times the $\\rho_{\\rm STP}$ of hydrogen gas. At this density, the absolute yields of kaonic X-rays, when a negatively charged kaon stopped inside the target, were determined to be 0.012$^{+0.004}_{-0.003}$ for $K_{\\alpha}$ and 0.043$^{+0.012}_{-0.011}$ for all the $K$-series transitions $K_{tot}$. These results, together with the KEK E228 experiment results, confirm for the first time a target density dependence of the yield predicted by the cascade models, and provide valuable information to refine the parameters used in the cascade models for the kaonic atoms.

  10. X-ray fluorescence/Auger-electron coincidence spectroscopy of vacancy cascades in atomic argon

    Energy Technology Data Exchange (ETDEWEB)

    Arp, U. [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Electron and Optical Physics Div.; LeBrun, T.; Southworth, S.H.; Jung, M. [Argonne National Lab., IL (United States). Physics Div.; MacDonald, M.A. [E.P.S.R.C. Daresbury Lab., Warrington (United Kingdom)

    1996-12-01

    Argon L{sub 2.3}-M{sub 2.3}M{sub 2.3} Auger-electron spectra were measured in coincidence with K{alpha} fluorescent x-rays in studies of Ar K-shell vacancy decays at several photon energies above the K-threshold and on the 1s-4p resonance in atomic argon. The complex spectra recorded by conventional electron spectroscopy are greatly simplified when recorded in coincidence with fluorescent x-rays, allowing a more detailed analysis of the vacancy cascade process. The resulting coincidence spectra are compared with Hartree-Fock calculations which include shake-up transitions in the resonant case. Small energy shifts of the coincidence electron spectra are attributed to post-collision interaction with 1s photoelectrons.

  11. Measurement of X-ray transmission factors of some boron compounds

    Energy Technology Data Exchange (ETDEWEB)

    Icelli, Orhan E-mail: orhan_icelli@hotmail.com; Erzeneoglu, Salih; Boncukcuogluc, Recep

    2003-12-01

    Measurements have been made to determine X-ray transmission factors of some boron compounds (H{sub 3}BO{sub 3},Na{sub 2}B{sub 4}O{sub 7} and B{sub 3}Al{sub 2}O{sub 3}) by using an extremely narrow-collimated-beam transmission method in the energy range 15.746-40.930 keV. The characteristic K{alpha} and K{beta} X-rays of the different elements (Zr, Mo, Ag, In, Sb, Ba and Pr) passed through boron compounds were detected with a high-resolution Si(Li) detector. Results are presented and discussed in this paper.

  12. X-ray spectral analysis of the low-luminosity active galactic nucleus NGC 7213 using long XMM-Newton observations

    CERN Document Server

    Emmanoulopoulos, D; Nicastro, F; McHardy, I M

    2012-01-01

    We present the X-ray spectral results from the longest X-ray multi-mirror mission-Newton observation, 133 ks, of the low luminosity active galactic nucleus NGC 7213. The hardness ratio analysis of the X-ray light curves discloses a rather constant X-ray spectral shape, at least for the observed exposure time, enabling us to perform X-ray spectral studies using the total observed spectrum. Apart from a neutral Fe K\\alpha emission line, we also detect narrow emission lines from the ionised iron species, Fe xxv and Fe xxvi. Our analysis suggests that the neutral Fe K\\alpha originates from a Compton-thin reflector, while the gas responsible for the high ionisation lines is collisionally excited. The overall spectrum, in the 0.3-10 keV energy band, registered by the European Photon Imaging Camera, can be modelled by a power-law component (with a slope of \\Gamma\\simeq1.9) plus two thermal components at 0.36 and 8.84 keV. The low-energy thermal component is entirely consistent with the X-ray spectral data obtained b...

  13. X-Ray Exam: Scoliosis (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Scoliosis KidsHealth > For Parents > X-Ray Exam: Scoliosis A A A What's in ... español Radiografía: escoliosis What It Is A scoliosis X-ray is a relatively safe and painless test ...

  14. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Neck KidsHealth > For Parents > X-Ray Exam: Neck A A A What's in ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that ...

  15. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Femur (Upper Leg) KidsHealth > For Parents > X-Ray Exam: Femur (Upper Leg) A A A ... español Radiografía: fémur What It Is A femur X-ray is a safe and painless test that ...

  16. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  17. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  18. XMM-Newton Spectroscopy of the X-ray Detected Broad Absorption Line QSO CSO 755

    Science.gov (United States)

    Brandt, Niel

    2005-01-01

    We present the results from XMM-Newton observations of the highly optically polarized broad absorption line quasar (BALQSO) CSO 755. By analyzing its X-ray spectrum with a total of approximately 3000 photons we find that this source has an X-ray continuum of "typical" radio-quiet quasars, with a photon index of Gamma=1.83, and a rather flat (X-ray bright) intrinsic optical-to-X-ray spectral slope of alpha_ox=- 1.51. The source shows evidence for intrinsic absorption, and fitting the spectrum with a neutral-absorption model gives a column density of N_H approximately 1.2x10^22 cm^{-2}; this is among the lowest X-ray columns measured for BALQSOs. We do not detect, with high significance, any other absorption features in the X-ray spectrum. Upper limits we place on the rest-frame equivalent width of a neutral (ionized) Fe K-alpha line, less than =180 eV (less than =120 eV), and on the Compton-reflection component parameter, R less than =0.2, suggest that most of the X-rays from the source are directly observed rather than being scattered or reflected; this is also supported by the relatively flat intrinsic alpha ox we measure. The possibility that most of the X-ray flux is scattered due to the high level of UV-optical polarization is ruled out. Considering data for 46 BALQSOs from the literature, including CSO 755, we have found that the UV-optical continuum polarization level of BALQSOs is not correlated with any of their X-ray properties. A lack of significant short-term and long-term X-ray flux variations in the source may be attributed to a large black-hole mass in CSO 755. We note that another luminous BALQSO, PG 2112+059, has both similar shallow C IV BALs and moderate X-ray absorption.

  19. The Suzaku Hard X-ray Survey on the Galactic Center Region

    CERN Document Server

    Tsuru, T G; Nobukawa, M; Sawada, M; Ryu, S G; Fukuoka, R; Koyama, K

    2010-01-01

    Diffuse X-rays from the Galactic center (GC) region were found to exhibit many K-shell lines from iron and nickel atoms in the 6--9 keV band. The strong emission lines seen in the spectrum are neutral iron K$\\alpha$ at 6.4~keV, He-like iron K$\\alpha$ at 6.7~keV, H-like iron Ly$\\alpha$ at 6.9~keV, and He-like iron K$\\beta$ at 7.8~keV. Among them, the 6.4~keV emission line is a probe of non-thermal phenomena. We have detected strong 6.4~keV emission in several giant molecular clouds, some of which were newly discovered by Suzaku. All the spectra exhibit large equivalent widths of 1-2~keV and absorption columns of $2-10\\times 10^{23}\\{\\rm H\\ cm}^{-2}$. We found time variability of diffuse 6.4~keV emission in the Sgr B2 region comparing the maps and spectra obtained from 1994 to 2005 with ASCA, Chandra, XMM-Newton and Suzaku. We also report discovery of K$\\alpha$ lines of neutral argon, calcium, chrome, and manganese atoms in the Sgr~A region. We show that the equivalent width of the 6.4~keV emission line detecte...

  20. The ^{55}Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

    CERN Document Server

    Fox, Ori D; Wen, Yiting; Foltz, Roger D; Hill, Robert J; Kimble, Randy A; Malumuth, Eliot; Rauscher, Bernard J

    2009-01-01

    A technique involving ^{55}Fe X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e^- ADU^{-1}), as well as aid detector design and performance studies. We calibrate the ^{55}Fe X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 \\micron flight grade detectors. The results show that each K$\\alpha$ X-ray generates 2273 \\pm 137 electrons, which corresponds to a pair-production energy of 2.61 \\pm 0.16 eV. The uncertainties are dominated by our knowledge of the conversion gain. In future studies, we plan to eliminate this uncertainty by directly measuring conversion gain at very low light levels.

  1. Shaped silicon wafers obtained by hot plastic deformation: performance evaluation for future astronomical x-ray telescopes.

    Science.gov (United States)

    Ezoe, Yuichiro; Shirata, Takayuki; Mitsuishi, Ikuyuki; Ishida, Manabu; Mitsuda, Kazuhisa; Morishita, Kohei; Nakajima, Kazuo

    2009-07-01

    In order to develop lightweight and high angular resolution x-ray mirrors, we have investigated hot plastic deformation of 4 in. silicon (111) wafers. A sample wafer was deformed using hemispherical dies with a curvature radius of 1000 mm. The measured radius of the deformed wafer was 1030 mm, suggesting that further conditioning is indispensable for better shaping. For the first time to our knowledge, x-ray reflection on a deformed wafer was detected at Al K(alpha) 1.49 keV. An estimated surface roughness of <1 nm from the x-ray reflection profile was comparable to that of a bare silicon wafer without deformation. Hence, no significant degradation of the microroughness was seen.

  2. X-Ray Visions of SS Cygni

    Science.gov (United States)

    Young, D. L.

    2004-12-01

    The Chandra X-Ray Observatory is the most sophisticated X-ray observatory launched by NASA. Chandra is designed to observe X-rays from highenergy regions of the universe, such as X-ray binary stars. On September 14, 2000, triggered by alerts from amateur astronomers worldwide, Chandra observed the outburst of the brightest northern dwarf nova SS Cygni. The cooperation of hundreds of amateur variable star astronomers and the Chandra X-Ray scientists and spacecraft specialists provided proof that the collaboration of amateur and professional astronomers is a powerful tool to study cosmic phenomena.

  3. X-ray Spectroscopy of Cooling Cluster

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, J.R.; /SLAC; Fabian, A.C.; /Cambridge U., Inst. of Astron.

    2006-01-17

    We review the X-ray spectra of the cores of clusters of galaxies. Recent high resolution X-ray spectroscopic observations have demonstrated a severe deficit of emission at the lowest X-ray temperatures as compared to that expected from simple radiative cooling models. The same observations have provided compelling evidence that the gas in the cores is cooling below half the maximum temperature. We review these results, discuss physical models of cooling clusters, and describe the X-ray instrumentation and analysis techniques used to make these observations. We discuss several viable mechanisms designed to cancel or distort the expected process of X-ray cluster cooling.

  4. Comets: mechanisms of x-ray activity

    Science.gov (United States)

    Ibadov, Subhon

    2016-07-01

    Basic mechanisms of X-ray activity of comets are considered, including D-D mechanism corresponding to generation of X-rays due to production of hot short-living plasma clumps at high-velocity collisions between cometary and interplanetary dust particles as well as M-M one corresponding to production of X-rays due to recombination of multicharge ions of solar wind plasma via charge exchange process at their collisions with molecules/atoms of the cometary atmospheres. Peculiarities of the variation of the comet X-ray spectrum and X-ray luminosity with variation of its heliocentric distance are revealed.

  5. X-rays from solar system objects

    CERN Document Server

    Bhardwaj, Anil; Gladstone, G Randall; Cravens, Thomas E; Lisse, Carey M; Dennerl, Konrad; Branduardi-Raymont, Graziella; Wargelin, Bradford J; Waite, J Hunter; Robertson, Ina; Ostgaard, Nikolai; Beiersdorfer, Peter; Snowden, Steven L; Kharchenko, Vasili; 10.1016/j.pss.2006.11.009

    2010-01-01

    During the last few years our knowledge about the X-ray emission from bodies within the solar system has significantly improved. Several new solar system objects are now known to shine in X-rays at energies below 2 keV. Apart from the Sun, the known X-ray emitters now include planets (Venus, Earth, Mars, Jupiter, and Saturn), planetary satellites (Moon, Io, Europa, and Ganymede), all active comets, the Io plasma torus (IPT), the rings of Saturn, the coronae (exospheres) of Earth and Mars, and the heliosphere. The advent of higher-resolution X-ray spectroscopy with the Chandra and XMM-Newton X-ray observatories has been of great benefit in advancing the field of planetary X-ray astronomy. Progress in modeling X-ray emission, laboratory studies of X-ray production, and theoretical calculations of cross-sections, have all contributed to our understanding of processes that produce X-rays from the solar system bodies. At Jupiter and Earth, both auroral and non-auroral disk X-ray emissions have been observed. X-ray...

  6. The iron $K_\\alpha$ lines as a tool for magnetic field estimations in non-flat accretion flows

    CERN Document Server

    Zakharov, A F; Bao, Y

    2004-01-01

    Observations of AGNs and microquasars by ASCA, RXTE, Chandra and XMM-Newton indicate the existence of broad X-ray emission lines of ionized heavy elements in their spectra. Such spectral lines were discovered also in X-ray spectra of neutron stars and X-ray afterglows of GRBs. Recently, Zakharov et al. (MNRAS, 2003, 342, 1325) described a procedure to estimate an upper limit of the magnetic fields in regions from which X-ray photons are emitted. The authors simulated typical profiles of the iron $K_\\alpha$ line in the presence of magnetic field and compared them with observational data in the framework of the widely accepted accretion disk model. Here we further consider typical Zeeman splitting in the framework of a model of non-flat accretion flows, which is a generalization of previous consideration into non-equatorial plane motion of particles emitting X-ray photons. Using perspective facilities of space borne instruments (e.g. Constellation-X mission) a better resolution of the blue peak structure of iro...

  7. A redshifted Fe K$\\alpha$ line from the unusual gamma-ray source PMN J1603-4904

    CERN Document Server

    Müller, C; Dauser, T; Kreikenbohm, A; Beuchert, T; Kadler, M; Ojha, R; Wilms, J; Böck, M; Carpenter, B; Markowitz, A; McConville, W; Pottschmidt, K; Stawarz, L; Taylor, G B

    2015-01-01

    Multiwavelength observations have revealed the highly unusual properties of the gamma-ray source PMN J1603-4904, which are difficult to reconcile with any other well established gamma-ray source class. The object is either a very atypical blazar or compact jet source seen at a larger angle to the line of sight. In order to determine the physical origin of the high-energy emission processes in PMN J1603-4904, we study the X-ray spectrum in detail. We performed quasi-simultaneous X-ray observations with XMM-Newton and Suzaku in 2013 September, resulting in the first high signal-to-noise X-ray spectrum of this source. The 2-10 keV X-ray spectrum can be well described by an absorbed power law with an emission line at 5.44$\\pm$0.05 keV (observed frame). Interpreting this feature as a K{\\alpha} line from neutral iron, we determine the redshift of PMN J1603-4904 to be z=0.18$\\pm$0.01, corresponding to a luminosity distance of 872$\\pm$54 Mpc. The detection of a redshifted X-ray emission line further challenges the or...

  8. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Hatoyama, Saitama (Japan). Advanced Research Lab.

    1996-08-01

    X-ray transmission imaging that creates image contrast from the distribution of the X-ray absorption coefficient is not sensitive to materials consisting of light elements such as hydrogen, carbon, nitrogen, and oxygen. On the other hand, the X-ray phase shift caused by the light elements is substantial enough to be detected even when absorption is almost zero. Hence, phase-contrast X-ray imaging is a promising technique for observing the structure inside biological soft tissues without the need for staining and without serious radiation exposure. Using fringe scanning X-ray interferometry, the X-ray phase shift caused by an object was measured. Three-dimensional image reconstruction of cancerous tissues using the measured phase shifts was enabled under tomographic configuration phase-contrast X-ray computed tomography (CT). (author)

  9. Probing AGN with Masers and X-Rays-SAX Proposals

    Science.gov (United States)

    Wilkes, Belinda J.; White, Nicholas (Technical Monitor)

    2001-01-01

    We have made BeppoSAX observations of the Seyfert 2/1.9 galaxy ESO103-G35, which contains a nuclear maser source and is known to be heavily absorbed in the X-rays. Analysis of the X-ray spectra observed by SAX in October 1996 and 1997 yields an energy index = 0.74 +/- 0.07, typical of Seyfert galaxies and consistent with earlier observations of this source. The strong, soft X-ray absorption has a column density, N_H of (1.79 +/- 0.09)E23 cmE-02, again consistent with earlier results. The best fitting spectrum is that of a power law with a high energy cutoff at 29 +/- 10 keV, a cold (E=6.3 +/- 0.1 keV, rest frame), marginally resolved (sigma = 0.35 +/- 0.14 keV, FWHM approximately (31 +/- 12)E03 km/s) FeKalpha line with EW 290 +100 -80 eV (1996) and a mildly ionized Fe K-edge at 7.37 +0.15 -0.21 keV, tau 0.24 +0.06 -0.09. The Fe Kalpha line and cold absorption are consistent with origin in a accretion disk/torus through which our line-of-sight passes at a radial distance of approximately 0.01 pc. The Fe K-edge is mildly ionized suggesting the presence of ionized gas probably in the inner accretion disk, close to the central source or in a separate warm absorber. The data quality is too low to distinguish between these possibilities but the edge-on geometry implied by the water maser emission favors the former. Comparison with earlier observations of ESO103-G35 shows little/no change in spectral parameters while the flux changes by factors of a few on timescales of a few months. The 2-10 keV flux decreased by a factor of approximately 2.7 between Oct 1996 and Oct 1997 with no detectable change in the count rate greater than 20 keV (i.e. the PDS data). Spectral fits to the combined datasets indicate either a significant hardening of the spectrum (energy index approximately 0.5) or an approximate constant or delayed response reflection component. The high energy cutoff (29 +/- 10 keV) is lower than the typical approximately 300 keV values seen in Seyfert galaxies. A

  10. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

    Science.gov (United States)

    Sun, Tianxi; Macdonald, C A

    2013-02-07

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  11. Phase contrast micro-CT with an ultrafast laser-based x-ray source

    Science.gov (United States)

    Toth, R.; Kieffer, J. C.; Krol, A.; Fourmaux, S.; Ozaki, T.; Ye, H.; Kincaid, R. E., Jr.; Rakhman, A.

    2005-08-01

    We investigated performance of ultrafast laser-based x-ray source for phase contrast imaging in 2D projection imaging and in enhanced micro-CT imaging. Good quality images were obtained, including images of small animals, in the single energy and multiple energy, in line phase-contrast enhancing geometry using x-ray line energy matching object thickness and density. Phase information has been inferred from images obtained at the same x-ray energy but at different object-to-detector distances and also from images obtained at the same object-to-detector distance but with different K-alpha line energies. Ultrafast laser-based, compact, x-ray source is a promising technique for micro-CT systems. Its utilization might result in faster scans with lower radiation dose, better spatial and contrast resolution and also femtosecond temporal resolution. In addition, it might allow practical implementation of dual-energy and phase-contrast imaging micro-CT that is not possible with conventional micro-CT.

  12. General relativistic modelling of the negative reverberation X-ray time delays in AGN

    CERN Document Server

    Emmanoulopoulos, D; Dovciak, M; McHardy, I M

    2014-01-01

    We present the first systematic physical modelling of the time-lag spectra between the soft (0.3-1 keV) and the hard (1.5-4 keV) X-ray energy bands, as a function of Fourier frequency, in a sample of 12 active galactic nuclei which have been observed by XMM-Newton. We concentrate particularly on the negative X-ray time-lags (typically seen above $10^{-4}$ Hz) i.e. soft band variations lag the hard band variations, and we assume that they are produced by reprocessing and reflection by the accretion disc within a lamp-post X-ray source geometry. We also assume that the response of the accretion disc, in the soft X-ray bands, is adequately described by the response in the neutral iron line (Fe k$\\alpha$) at 6.4 keV for which we use fully general relativistic ray-tracing simulations to determine its time evolution. These response functions, and thus the corresponding time-lag spectra, yield much more realistic results than the commonly-used, but erroneous, top-hat models. Additionally we parametrize the positive ...

  13. Effect of X-Rays on the Mechanical Properties of Aluminized FEP Teflon(trademark)

    Science.gov (United States)

    Gaier, James R.; Brinkmeier, Michael R.; Gaier, Elizabeth M.

    1999-01-01

    Pieces of the multilayer insulation (MLI) that is integral to the thermal control of the Hubble Space Telescope (HST) have been returned by two servicing missions after 3.6 and 6.8 years in orbit. They reveal that the outer layer, which is made from 5 mil (0.13 mm) thick aluminized fluorinated ethylenepropylene (FEP) Teflon. has become severely embrittled. Although possible agents of this embrittlement include electromagnetic radiation across the entire solar spectrum, trapped particle radiation, atomic oxygen, and thermal cycling, intensive investigations have not yielded unambiguous causes. Previous studies utilizing monoenergetic photons in the 69-1900 eV range did not cause significant embrittlement, even at much higher doses than were experienced by the HST MLI. Neither did x-rays in the 3 to 10 keV range generated in a modified electron bean evaporator. An antidotal aluminized FEP sample that was exposed to an intensive dose from unfiltered Mo x-ray radiation from a rotating anode generator, however, did show the requisite embrittlement. Thus, a study was undertaken to determine the effects of x-ray exposure on the embrittlement of aluminized FEP in hopes that it might elucidate the HST MLI degradation mechanism. Tensile specimens of aluminized 5 mil thick FEP were exposed to a constant fluence of unfiltered x-ray radiation from a Mo target whose maximum energy ranged from 20-60 kV. Other samples were annealed, thermally cycled (100x) between 77-333 K, or cycled and irradiated. Tensile tests and density measurements were then performed on the samples. Only the samples which had been irradiated had the drastically reduced elongation-to-break, characteristic of the HST samples. Thermal cycling may accelerate the embrittlement, but the effect was near the scatter in the measurements. Annealing and thermal cycling had no apparent effect. Only the samples which had been irradiated and annealed showed significant density increases, likely implicating polymer chain

  14. Design and characterization of a phase contrast X-ray CT system

    Science.gov (United States)

    Zambelli, Joseph N.

    Phase contrast x-ray imaging has recently attracted wide research interest, as it offers the possibility to exploit different contrast mechanisms than conventional absorption imaging, with the potential for higher quality images or more available information as a result. This work details design and construction of au experimental grating-interferometer-based differential phase contrast computed tomography (DPC-CT) imaging system, presents measurements of performance, and compares this new imaging technique with conventional absorption imaging. Details of the fabrication of the specialized x-ray phase and absorption gratings are also provided. This system is unique in that makes use of a conventional rotating-anode x-ray tube, unlike previous designs which were based upon stationary anode x-ray tubes or synchrotron sources. The imaging system described here enables simultaneous reconstruction of electron density, effective atomic number, attenuation coefficient, and small-angle scatter density with data acquired from a single scan. It is theoretically shown and experimentally verified that DPC-CT imaging allows imaging of electron density at high spatial resolution with a much less severe dose penalty compared with conventional absorption imaging. Improved object visibility using electron density imaging is demonstrated with CNR measurements in physical phantoms and comparisons of reconstructions of breast tissue samples. The ability to directly image both electron density and effective atomic number provides a truly quantitative imaging technique and accuracy of the technique is shown using phantoms and potential applications are demonstrated using breast tissue samples. A new reconstruction algorithm which allows a doubling of the diameter of the scanning field of view, a potential enabling technology for eventual clinical use, is also demonstrated.

  15. ORNL 10-m small-angle X-ray scattering camera

    Energy Technology Data Exchange (ETDEWEB)

    Hendricks, R.W.

    1979-12-01

    A new small-angle x-ray scattering camera utilizing a rotating anode x-ray source, crystal monochromatization of the incident beam, pinhole collimation, and a two-dimensional position-sensitive proportional counter was developed. The sample, and the resolution element of the detector are each approximately 1 x 1 mm/sup 2/, the camera was designed so that the focal spot-to-sample and sample-to-detector distances may each be varied in 0.5-m increments up to 5 m to provide a system resolution in the range 0.5 to 4.0 mrad. A large, general-purpose specimen chamber has been provided into which a wide variety of special-purpose specimen holders can be mounted. The detector has an active area of 200 x 200 mm and has up to 200 x 200 resolution elements. The data are recorded in the memory of a minicomputer by a high-speed interface which uses a microprocessor to map the position of an incident photon into an absolute minicomputer memory address. The data recorded in the computer memory can be processed on-line by a variety of programs designed to enhance the user's interaction with the experiment. At the highest angular resolution (0.4 mrad), the flux incident on the specimen is 1.0 x 10/sup 6/ photons/s with the x-ray source operating at 45 kV and 100 mA. SAX and its associated programs OVF and MOT are high-priority, pre-queued, nonresident foreground tasks which run under the ModComp II MAX III operating system to provide complete user control of the ORNL 10-m small-angle x-ray scattering camera.

  16. X-Ray Attenuation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Toor, A.

    2000-03-03

    To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3rd-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intensity by many orders of magnitude without increasing the pulse-to-pulse variation. In this report we consider a possible solution for controlled attenuation of the LCLS x-ray radiation. We suggest using for this purpose a windowless gas-filled cell with the differential pumping. Although this scheme is easily realizable in principle, it has to be demonstrated that the attenuator can be made short enough to be practical and that the gas loads delivered to the vacuum line of sight (LOS) are acceptable. We are not going to present a final, optimized design. Instead, we will provide a preliminary analysis showing that the whole concept is robust and is worth further study. The spatial structure of the LCLS x-ray pulse at the location of the attenuator is shown in Fig. 1. The central high-intensity component, due to the FEL, has a FWHM of {approx}100 {micro}m. A second component, due to the undulator's broad band spontaneous radiation is seen as a much lower intensity ''halo'' with a FWHM of 1 mm. We discuss two versions of the attenuation cell. The first is directed towards a controlled attenuation of the FEL up to the 4 orders of magnitude in the intensity, with the spontaneous radiation halo being eliminated by collimators. In the second version, the spontaneous radiation is not sacrificed but the FEL component (as well as the first harmonic of the spontaneous radiation) gets attenuated by a more modest factor up to 100. We will make all the estimates assuming that the gas used in the attenuator is Xenon and that the energy of the FEL is 8.25 keV. At

  17. Controlling X-rays With Light

    Energy Technology Data Exchange (ETDEWEB)

    Glover, Ernie; Hertlein, Marcus; Southworth, Steve; Allison, Tom; van Tilborg, Jeroen; Kanter, Elliot; Krassig, B.; Varma, H.; Rude, Bruce; Santra, Robin; Belkacem, Ali; Young, Linda

    2010-08-02

    Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

  18. High resolution x-ray fluorescence spectroscopy - a new technique for site- and spin-selectivity

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xin [Univ. of California, Davis, CA (United States). Dept. of Applied Science

    1996-12-01

    X-ray spectroscopy has long been used to elucidate electronic and structural information of molecules. One of the weaknesses of x-ray absorption is its sensitivity to all of the atoms of a particular element in a sample. Through out this thesis, a new technique for enhancing the site- and spin-selectivity of the x-ray absorption has been developed. By high resolution fluorescence detection, the chemical sensitivity of K emission spectra can be used to identify oxidation and spin states; it can also be used to facilitate site-selective X-ray Absorption Near Edge Structure (XANES) and site-selective Extended X-ray Absorption Fine Structure (EXAFS). The spin polarization in K fluorescence could be used to generate spin selective XANES or spin-polarized EXAFS, which provides a new measure of the spin density, or the nature of magnetic neighboring atoms. Finally, dramatic line-sharpening effects by the combination of absorption and emission processes allow observation of structure that is normally unobservable. All these unique characters can enormously simplify a complex x-ray spectrum. Applications of this novel technique have generated information from various transition-metal model compounds to metalloproteins. The absorption and emission spectra by high resolution fluorescence detection are interdependent. The ligand field multiplet model has been used for the analysis of K{alpha} and K{beta} emission spectra. First demonstration on different chemical states of Fe compounds has shown the applicability of site selectivity and spin polarization. Different interatomic distances of the same element in different chemical forms have been detected using site-selective EXAFS.

  19. Diffractive X-Ray Telescopes

    Science.gov (United States)

    Skinner, Gerald K.

    2010-01-01

    Diffractive X-ray telescopes, using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution many orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the super-massive black holes in the center of active galaxies. What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  20. Diffractive X-ray Telescopes

    CERN Document Server

    Skinner, Gerald K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted space- time in the immediate vicinity of the super-massive black holes in the center of active galaxies What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  1. K-Alpha Emission Spectra From Non-Equilibrium Ionizing Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, V L; Decaux, V; Beiersdorfer, P

    2004-12-16

    K{alpha} X-ray emission spectra from highly charged Fe ions have been theoretically predicted using a detailed and systematic spectral model. Account has been taken of the fundamental atomic radiative-emission processes associated with inner-shell electron collisional excitation and ionization, as well as dielectronic recombination. Particular emphasis has been directed at extreme non-equilibrium or transient-ionization conditions, which can occur in astrophysical and tokamak plasmas. Good agreement has been found in comparisons with spectral observations on the EBIT-II electron beam ion trap at the Lawrence Livermore National Laboratory. We have identified spectral features that can serve as diagnostics of the electron density, the line-formation mechanism, and the charge-state distribution.

  2. Dependence of the broad Fe K$\\alpha$ line on the physical parameters of AGN

    CERN Document Server

    Liu, Zhu; Lu, Youjun; Carrera, Francisco J; Falocco, Serena; Dong, Xiao-Bo

    2016-01-01

    In this paper, the dependence of the broad Fe K$\\alpha$ line on the physical parameters of AGN, such as the black hole mass $M_{BH}$, accretion rate (equivalently represented by Eddington ratio $\\lambda_{Edd}$), and optical classification, is investigated by applying the X-ray spectra stacking method to a large sample of AGN which have well measured optical parameters. A broad line feature is detected ($>3\\sigma$) in the stacked spectra of the high $\\lambda_{Edd}$ sub-sample ($\\log\\lambda_{Edd}>-0.9$). The profile of the broad line can be well fitted with relativistic broad line model, with the line energy consistent with highly ionized Fe K$\\alpha$ line (i.e. Fe xxvi). A model consisting of multiple narrow lines cannot be ruled out, however. We found hints that the Fe K line becomes broader as the $\\lambda_{Edd}$ increases. No broad line feature is shown in the sub-sample of broad-line Seyfert 1 (BLS1) galaxies and in the full sample, while a broad line might be present, though at low significance, in the su...

  3. Contribution of multielectron excitation to F 1s photoabsorption process in CaF{sub 2} studied by soft X-ray absorption and emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Oura, M. [RIKEN/SPring-8, Harima Institute, 1-1-1 Kouto, Mikazuki, Sayo, Hyogo 679-5148 (Japan)]. E-mail: oura@spring8.or.jp; Taguchi, M. [RIKEN/SPring-8, Harima Institute, 1-1-1 Kouto, Mikazuki, Sayo, Hyogo 679-5148 (Japan); Mukoyama, T. [Kansai Gaidai University, 16-1 Nakamiya-Higashino-cho, Hirakata, Osaka 573-1001 (Japan); Takeuchi, T. [RIKEN/SPring-8, Harima Institute, 1-1-1 Kouto, Mikazuki, Sayo, Hyogo 679-5148 (Japan); Tokyo University of Science, 1-3 Kagurazaka, Shinjuku, Tokyo 162-8601 (Japan); Shin, S. [RIKEN/SPring-8, Harima Institute, 1-1-1 Kouto, Mikazuki, Sayo, Hyogo 679-5148 (Japan); ISSP/University of Tokyo, Kashiwanoha, Kashiwa, Chiba 277-8581 (Japan)

    2005-06-15

    The photoexcited F K{alpha} X-ray intensity's evolution was measured for CaF{sub 2} with fine energy-step from the [1s2p] double excitation threshold to the saturation region, where square brackets indicate hole states. The observed evolution was directly compared with the X-ray absorption spectrum, and the contribution of multielectron excitation to the absorption spectrum was successfully resolved. The F-K fluorescence XANES spectra were calculated based on the coherent second-order optical processes for comparison.

  4. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  5. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  6. X-ray generation using carbon nanotubes

    OpenAIRE

    Parmee, Richard J.; Collins, Clare M.; William I. Milne; Cole, Matthew T.

    2015-01-01

    This is the final published version. It first appeared at http://www.nanoconvergencejournal.com/content/2/1/1. Since the discovery of X-rays over a century ago the techniques applied to the engineering of X-ray sources have remained relatively unchanged. From the inception of thermionic electron sources, which, due to simplicity of fabrication, remain central to almost all X-ray applications, there have been few fundamental technological advances. However, with the emergence of ever more d...

  7. Applications of soft x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, C.H.

    1993-08-01

    The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed.

  8. Topological X-Rays and MRIs

    Science.gov (United States)

    Lynch, Mark

    2002-01-01

    Let K be a compact subset of the interior of the unit disk D in the plane and suppose one can't see through the boundary of D and identify K. However, assume that one can take "topological X-rays" of D which measure the "density" of K along the lines of the X-rays. By taking these X-rays from all directions, a "topological MRI" is generated for…

  9. Observation of femtosecond X-ray interactions with matter using an X-ray-X-ray pump-probe scheme.

    Science.gov (United States)

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru; Yabashi, Makina

    2016-02-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼10(19) W/cm(2)) XFEL pulses. An X-ray pump-probe diffraction scheme was developed in this study; tightly focused double-5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray-induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray-matter interactions. The X-ray pump-probe scheme demonstrated here would be effective for understanding ultraintense X-ray-matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities.

  10. Development of low temperature and high magnetic field X-ray diffraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Shahee, Aga; Sharma, Shivani; Singh, K.; Lalla, N. P., E-mail: nplallaiuc82@gmail.com; Chaddah, P. [UGC-DAE Consortium for Scientific Research, University campus, Khandwa Road, Indore-452001 (India)

    2015-06-24

    The current progress of materials science regarding multifunctional materials (MFM) has put forward the challenges to understand the microscopic origin of their properties. Most of such MFMs have magneto-elastic correlations. To investigate the underlying mechanism it is therefore essential to investigate the structural properties in the presence of magnetic field. Keeping this in view low temperature and high magnetic field (LTHM) powder x-ray diffraction (XRD), a unique state-of-art facility in the country has been developed at CSR Indore. This setup works on symmetric Bragg Brentano geometry using a parallel incident x-ray beam from a rotating anode source working at 17 kW. Using this one can do structural studies at non-ambient conditions i.e. at low- temperatures (2-300 K) and high magnetic field (+8 to −8 T). The available scattering angle ranges from 5° to 115° 2θ with a resolution better than 0.1°. The proper functioning of the setup has been checked using Si sample. The effect of magnetic field on the structural properties has been demonstrated on Pr{sub 0.5}Sr{sub 0.5}MnO{sub 3} sample. Clear effect of field induced phase transition has been observed. Moreover, the effect of zero field cooled and field cooled conditions is also observed.

  11. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  12. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; Coppi, Paolo; Wu, Kinwah; Siegmund, Oswald

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  13. The efficacy of x-ray pelvimetry

    Energy Technology Data Exchange (ETDEWEB)

    Barton, J.J. (Univ. of Illinois, Chicago); Garbaciak, J.A. Jr.; Ryan, G.M., Jr.

    1982-06-01

    Comparison is made of x-ray pelvimetry use on a public and private service in 1974 with experience in 1979, when the clinic service did no x-ray pelvimetry while the private service continued as before. It is concluded that the use of x-ray pelvimetry is inadequate as a predictor of cesarean section because of cephalopelvic disproportion, does not improve neonatal mortality, and poses potential hazards to the mother and fetus. Its use in the management of breech presentations is not currently established by our data. Guidelines are presented for the management of patients in labor without using x-ray pelvimetry.

  14. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  15. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  16. Hard X-ray Modulation Telescope

    Institute of Scientific and Technical Information of China (English)

    LU Fangjun

    2011-01-01

    The Hard X-ray Modulation Telescope (HXMT) will be China's first astronomical satellite. On board HXMT there are three kinds of slat-collimated telescopes, the High Energy X-ray Telescope (HE, 20-250 keV, 5000 cm^2), the Medium Energy X-ray Telescope (ME, 5-30 keV, 952 cm^2), and the Low Energy X-ray Telescope (LE, 1-15 keV, 384 cm^2).

  17. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90{sup o} Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated {approx} 300 fs, 30 keV (0.4 {angstrom}) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has

  18. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; hide

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  19. X-rays from the youngest stars

    Science.gov (United States)

    Feigelson, Eric D.

    1994-01-01

    The X-ray properties of classical and weak-lined T Tauri stars are briefly reviewed, emphasizing recent results from the ROSAT satellite and prospects for ASCA. The interpretation of the high level of T Tauri X-rays as enhanced solar-type magnetic activity is discussed and criticized. The census of X-ray emitters is significantly increasing estimates of galactic star formation efficiency, and X-ray emission may be important for self-regulation of star formation. ASCA images will detect star formation regions out to several kiloparsecs and will study the magnetically heated plasma around T Tauri stars. However, images will often suffer from crowding effects.

  20. X-ray emission from comets.

    Science.gov (United States)

    Cravens, T E

    2002-05-10

    The discovery of x-ray emission from comet Hyakutake was surprising given that comets are known to be cold. Observations by x-ray satellites such as the Röntgen Satellite (ROSAT) indicate that x-rays are produced by almost all comets. Theoretical and observational work has demonstrated that charge-exchange collisions of highly charged solar wind ions with cometary neutral species can explain this emission. X-ray observations of comets and other solar system objects may be used to determine the structure and dynamics of the solar wind.

  1. X-ray pulsar rush in 1998

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, K.; Tsujimoto, K.; Nishiuchi, Mamiko; Yokogawa, J.; Koyama, K. [Kyoto Univ., Faculty of Science, Kyoto (Japan)

    1999-08-01

    We present recent remarkable topics about discoveries of X-ray pulsars. 1. Pulsations from two Soft Gamma-ray Repeaters: These pulsars have enormously strong magnetic field (B {approx} 10{sup 15} G), thus these are called as 'magnetar', new type of X-ray pulsars. 2. New Crab-like pulsars: These discoveries lead to suggesting universality of Crab-like pulsars. 3. An X-ray bursting millisecond pulsar: This is strong evidence for the recycle theory of generating radio millisecond pulsars. 4. X-ray pulsar rush in the SMC: This indicates the younger star formation history in the SMC. (author)

  2. Revealing the broad iron Kalpha line in Cygnus X-1 through simultaneous XMM-Newton, RXTE, and INTEGRAL observations

    CERN Document Server

    Duro, Refiz; Grinberg, Victoria; Miškovičová, Ivica; Rodriguez, Jérôme; Tomsick, John; Hanke, Manfred; Pottschmidt, Katja; Nowak, Michael A; Kreykenbohm, Sonja; Bel, Marion Cadolle; Bodaghee, Arash; Lohfink, Anne; Kendziorra, Eckhard; Kirsch, Marcus G F; Staubert, Rüdiger; Wilms, Jörn

    2016-01-01

    We report on the analysis of the broad Fe Kalpha line feature of Cygnus X-1 in the spectra of four simultaneous hard intermediate state observations made with the X-ray Multiple Mirror mission (XMM-Newton), the Rossi X-ray Timing Explorer (RXTE), and the International Gamma-Ray Astrophysics Laboratory (INTEGRAL). The high quality of the XMM-Newton data taken in the Modified Timing Mode of the EPIC-pn camera provides a great opportunity to investigate the broadened Fe Kalpha reflection line at 6.4keV with a very high signal to noise ratio. The 4-500keV energy range is used to constrain the underlying continuum and the reflection at higher energies. We first investigate the data by applying a phenomenological model that consists of the sum of an exponentially cutoff power law and relativistically smeared reflection. Additionally, we apply a more physical approach and model the irradiation of the accretion disk directly from the lamp post geometry. All four observations show consistent values for the black hole ...

  3. On the equivalent width of the Fe K$\\alpha$ line produced by a dusty absorber in active galactic nuclei

    CERN Document Server

    Gohil, Raj

    2015-01-01

    Obscured AGNs provide an opportunity to study the material surrounding the central engine. Geometric and physical constraints on the absorber can be deduced from the reprocessed AGN emission. In particular, the obscuring gas may reprocess the nuclear X-ray emission producing a narrow Fe K$\\alpha$ line and a Compton reflection hump. In recent years, models of the X-ray reflection from an obscuring torus have been computed; however, although the reflecting gas may be dusty, the models do not yet take into account the effects of dust on the predicted spectrum. We study this problem by analyzing two sets of models, with and without the presence of dust, using the one dimensional photo-ionization code Cloudy. The calculations are performed for a range of column densities ($22 <{\\rm log}[N_H(\\rm cm^{-2})]< 24.5$ ) and hydrogen densities ( $6 <{\\rm log}[n_H(\\rm cm^{-3})]< 8$). The calculations show the presence of dust can enhance the Fe K$\\alpha$ equivalent width (EW) in the reflected spectrum by factor...

  4. Muonic X-ray spectroscopy: Effect of the presence of protons on X-ray production

    National Research Council Canada - National Science Library

    Mohamadsalehi, F; Gheisari, R; Rahimi, N

    2016-01-01

    ... . The target has a high efficiency for analyzing characteristic X-rays in ion implantation. To predict the effect of the presence of protons on X-ray production, we have proposed a new kinetic schema...

  5. SMM X-ray polychromator

    Science.gov (United States)

    Strong, Keith T.; Haisch, Bernhard M. (Compiler); Lemen, James R. (Compiler); Acton, L. W.; Bawa, H. S.; Claflin, E. S.; Freeland, S. L.; Slater, G. L.; Kemp, D. L.; Linford, G. A.

    1988-01-01

    The range of observing and analysis programs accomplished with the X-Ray Polychromator (XRP) instruments during the decline of solar cycle 21 and the rise of the solar cycle 22 is summarized. Section 2 describes XRP operations and current status. This is meant as a guide on how the instrument is used to obtain data and what its capabilities are for potential users. The science section contains a series of representative abstracts from recently published papers on major XRP science topics. It is not meant to be a complete list but illustrates the type of science that can come from the analysis of the XRP data. There then follows a series of appendixes that summarize the major data bases that are available. Appendix A is a complete bibliography of papers and presentations produced using XRP data. Appendix B lists all the spectroscopic data accumulated by the Flat Crystal Spectrometer (FCS). Appendix C is a compilation of the XRP flare catalogue for events equivalent to a GOES C-level flare or greater. It lists the start, peak and end times as well as the peak Ca XIX flux.

  6. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  7. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  8. A Chandra X-ray Study of Cygnus A. 2; The Nucleus

    Science.gov (United States)

    Young, Andrew J.; Wilson, Andrew; Terashima, Yuichi; Arnaud, Keith A.; Smith, David A.; White, Nicholas E. (Technical Monitor)

    2002-01-01

    We report Chandra Advanced CCD Imaging Spectrometer and quasi-simultaneous Rossi X-Ray Timing Explorer (RXTE) observations of the nearby, powerful radio galaxy Cygnus A, with the present paper focusing on the properties of the active nucleus. In the Chandra observation, the hard (less than a few keV) X-ray emission is spatially unresolved with a size is approximately 1" (1.5 kpc, H(sub 0) = 50 km/s/Mpc) and coincides with the radio and near-infrared nuclei. In contrast, the soft (less than 2 keV) emission exhibits a bipolar nebulosity that aligns with the optical bipolar continuum and emission-line structures and approximately with the radio jet. In particular, the soft X-ray emission corresponds very well with the [O III] (lambda)5007 and H(alpha) + [N II] lambda(lambda)6548, 6583 nebulosity imaged with Hubble Space Telescope. At the location of the nucleus, there is only weak soft X-ray emission, an effect that may be intrinsic or result from a dust lane that crosses the nucleus perpendicular to the source axis. The spectra of the various X-ray components have been obtained by simultaneous fits to the six detectors. The compact nucleus is detected to 100 keV and is well described by a heavily absorbed power-law spectrum with Gamma(sub h) = 1.52(sup + 0.12, sub -0.12) (similar to other 0.12 narrow-line radio galaxies) and equivalent hydrogen column N(sub H)(nuc) = 2.0(sup +0.1, sub -0.1) x 10(exp 23)/sq cm. This 0.2 column is compatible with the dust obscuration to the near-infrared source for a normal gas-to-dust ratio. The soft (less than 2 keV) emission from the nucleus may be described by a power-law spectrum with the same index (i.e., Gamma(sub l) = Gamma(sub h), although direct fits suggest a slightly larger value for Gamma(sub l). Narrow emission lines from highly ionized neon and silicon, as well as a "neutral" Fe K(alpha) line, are detected in the nucleus and its vicinity (r approximately less than 2 kpc). The equivalent width (EW) of the Fe K(alpha) line

  9. X-ray lasers: Multicolour emission

    Science.gov (United States)

    Feng, Chao; Deng, Haixiao

    2016-11-01

    The X-ray free-electron laser at the SLAC National Accelerator Laboratory in the US can now generate multicolour X-ray pulses with unprecedented brightness using the fresh-slice technique. The development opens the way to new forms of spectroscopy.

  10. X-Ray Detection Visits the Classroom

    Science.gov (United States)

    Peralta, Luis; Farinha, Ana; Pinto, Ana

    2008-01-01

    Film has been used to detect x-rays since the early days of their discovery by Rontgen. Although nowadays superseded by other techniques, film still provides a cheap means of x-ray detection, making it attractive in high-school or undergraduate university courses. If some sort of quantitative result is required, the film's optical absorbance or…

  11. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  12. X-raying clumped stellar winds

    CERN Document Server

    Oskinova, L M; Feldmeier, A

    2008-01-01

    X-ray spectroscopy is a sensitive probe of stellar winds. X-rays originate from optically thin shock-heated plasma deep inside the wind and propagate outwards throughout absorbing cool material. Recent analyses of the line ratios from He-like ions in the X-ray spectra of O-stars highlighted problems with this general paradigm: the measured line ratios of highest ions are consistent with the location of the hottest X-ray emitting plasma very close to the base of the wind, perhaps indicating the presence of a corona, while measurements from lower ions conform with the wind-embedded shock model. Generally, to correctly model the emerging X-ray spectra, a detailed knowledge of the cool wind opacities based on stellar atmosphere models is prerequisite. A nearly grey stellar wind opacity for the X-rays is deduced from the analyses of high-resolution X-ray spectra. This indicates that the stellar winds are strongly clumped. Furthermore, the nearly symmetric shape of X-ray emission line profiles can be explained if t...

  13. X-rays, clumping and wind structures

    Science.gov (United States)

    Oskinova, Lidia; Hamann, Wolf-Rainer; Ignace, Richard; Feldmeier, Achim

    2011-01-01

    X-ray emission is ubiquitous among massive stars. In the last decade, X-ray observations revolutionized our perception of stellar winds but opened a Pandora's box of urgent problems. X-rays penetrating stellar winds suffer mainly continuum absorption, which greatly simplifies the radiative transfer treatment. The small and large scale structures in stellar winds must be accounted for to understand the X-ray emission from massive stars. The analysis of X-ray spectral lines can help to infer the parameters of wind clumping, which is prerequisite for obtaining empirically correct stellar mass-loss rates. The imprint of large scale structures, such as CIRs and equatorial disks, on the X-ray emission is predicted, and new observations are testing theoretical expectations. The X-ray emission from magnetic stars proves to be more diverse than anticipated from the direct application of the magnetically-confined wind model. Many outstanding questions about X-rays from massive stars will be answered when the models and the observations advance.

  14. Cryogenic imaging x-ray spectrometer

    NARCIS (Netherlands)

    Wiegerink, Remco J.; van Baar, J.J.J.; de Boer, J.H.; Ridder, M.L.; Bruijn, M.P.; Germeau, A.; Hoevers, H.F.C.

    2005-01-01

    A micro-calorimeter array consisting of superconducting transition-edge sensors is under development for the X-ray imaging spectrometer on board of ESA's XEUS (X-ray Evolving Universe Spectroscopy) mission. An array of 32 /spl times/ 32 pixels with a pixel size of 250 micron square is envisaged. So

  15. Low Energy X-Ray Diagnostics - 1981.

    Science.gov (United States)

    1981-01-01

    Filtering, and Scattering of Soft X-Rays by Mirrors Victor Rehn Michelson Laboratory, Physics Division Naval Weapons Center, China Lake, California...met with in K.Tregidgo, 18, 2003 (1979). the manufacture of X-ray optical components. In 32. W.P.Linnik, C. R. Acad. Sci. URSS ., 5, 210 (1933). general

  16. New Insights into X-ray Binaries

    CERN Document Server

    Casares, Jorge

    2009-01-01

    X-ray binaries are excellent laboratories to study collapsed objects. On the one hand, transient X-ray binaries contain the best examples of stellar-mass black holes while persistent X-ray binaries mostly harbour accreting neutron stars. The determination of stellar masses in persistent X-ray binaries is usually hampered by the overwhelming luminosity of the X-ray heated accretion disc. However, the discovery of high-excitation emission lines from the irradiated companion star has opened new routes in the study of compact objects. This paper presents novel techniques which exploits these irradiated lines and summarises the dynamical masses obtained for the two populations of collapsed stars: neutron stars and black holes.

  17. Perspectives of medical X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberger, J. E-mail: joerg.freudenberger@med.siemens.de; Hell, E.; Knuepfer, W

    2001-06-21

    While X-ray image intensifiers (XII), storage phosphor screens and film-screen systems are still the work horses of medical imaging, large flat panel solid state detectors using either scintillators and amorphous silicon photo diode arrays (FD-Si), or direct X-ray conversion in amorphous selenium are reaching maturity. The main advantage with respect to image quality and low patient dose of the XII and FD-Si systems is caused by the rise of the Detector Quantum Efficiency originating from the application of thick needle-structured phosphor X-ray absorbers. With the detectors getting closer to an optimal state, further progress in medical X-ray imaging requires an improvement of the usable source characteristics. The development of clinical monochromatic X-ray sources of high power would not only allow an improved contrast-to-dose ratio by allowing smaller average photon energies in applications but would also lead to new imaging techniques.

  18. Perspectives of medical X-ray imaging

    Science.gov (United States)

    Freudenberger, J.; Hell, E.; Knüpfer, W.

    2001-06-01

    While X-ray image intensifiers (XII), storage phosphor screens and film-screen systems are still the work horses of medical imaging, large flat panel solid state detectors using either scintillators and amorphous silicon photo diode arrays (FD-Si), or direct X-ray conversion in amorphous selenium are reaching maturity. The main advantage with respect to image quality and low patient dose of the XII and FD-Si systems is caused by the rise of the Detector Quantum Efficiency originating from the application of thick needle-structured phosphor X-ray absorbers. With the detectors getting closer to an optimal state, further progress in medical X-ray imaging requires an improvement of the usable source characteristics. The development of clinical monochromatic X-ray sources of high power would not only allow an improved contrast-to-dose ratio by allowing smaller average photon energies in applications but would also lead to new imaging techniques.

  19. An X-ray view of quasars

    CERN Document Server

    Singh, K P

    2013-01-01

    I present an overview of observational studies of quasars of all types, with particular emphasis on X-ray observational studies. The presentation is based on the most popularly accepted unified picture of quasars - collectively referred to as AGN (active galactic nuclei) in this review. Characteristics of X-ray spectra and X-ray variability obtained from various X-ray satellites over the last 5 decades have been presented and discussed. The contribution of AGN in understanding the cosmic X-ray background is discussed very briefly. Attempt has been made to provide up-to-date information; however, this is a vast subject and this presentation is not intended to be comprehensive.

  20. LOBSTER - New Space X-Ray telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Hudec, R. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Pina, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Simon, V. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Sveda, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Inneman, A.; Semencova, V. [Center for Advanced X-ray Technologies, Reflex, Prague (Czech Republic); Skulinova, M. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic)

    2007-04-15

    We discuss the technological and scientific aspects of fully innovative very wide-field X-ray telescopes with high sensitivity. The prototypes of Lobster telescopes designed, developed and tested are very promising, allowing the proposals for space projects with very wide-field Lobster Eye X-ray optics to be considered for the first time. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study of various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. For example, the Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science.

  1. High Energy Vision: Processing X-rays

    CERN Document Server

    DePasquale, Joseph; Edmonds, Peter

    2015-01-01

    Astronomy is by nature a visual science. The high quality imagery produced by the world's observatories can be a key to effectively engaging with the public and helping to inspire the next generation of scientists. Creating compelling astronomical imagery can, however, be particularly challenging in the non-optical wavelength regimes. In the case of X-ray astronomy, where the amount of light available to create an image is severely limited, it is necessary to employ sophisticated image processing algorithms to translate light beyond human vision into imagery that is aesthetically pleasing while still being scientifically accurate. This paper provides a brief overview of the history of X-ray astronomy leading to the deployment of NASA's Chandra X-ray Observatory, followed by an examination of the specific challenges posed by processing X-ray imagery. The authors then explore image processing techniques used to mitigate such processing challenges in order to create effective public imagery for X-ray astronomy. ...

  2. Globular Cluster X-ray Sources

    CERN Document Server

    Verbunt, F

    2004-01-01

    After a brief historical overview we discuss the luminous X-ray sources in globular clusters of our Galaxy. This is followed by an overview of the very luminous X-ray sources studied in globular clusters of 14 other galaxies, and a discussion of their formation and the relation to X-ray sources outside globular clusters. We describe the discovery and classification of low-luminosity X-ray sources, and end the review with some remarks on the formation and evolution of X-ray sources in globular clusters. Observational results are summarized in three tables. Comments are very welcome. Please send them to F.W.M.Verbunt@astro.uu.nl and lewin@mit.edu.

  3. X-Rays from Green Pea Analogs

    Science.gov (United States)

    Brorby, Matthew

    2014-09-01

    X-rays may have contributed to the heating and reionization of the IGM in the early universe. High mass X-ray binaries (HMXB) within small, low-metallicity galaxies are expected to be the main source of X-rays at this time. Since studying these high-redshift galaxies is currently impossible, we turn to local analogs that have the same properties the galaxies in the early are expected to have. A number of recent studies have shown an enhanced number of HMXBs in nearby low metallicity galaxies. We propose to observe a sample of metal-deficient luminous compact galaxies (LCG) in order to determine if the X-ray luminosity is enhanced relative to SFR, thereby providing further evidence to the importance of X-rays in the early universe.

  4. X-ray Fourier ptychographic microscopy

    CERN Document Server

    Simons, H; Guigay, J P; Detlefs, C

    2016-01-01

    Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution, wide field of view images into a high-resolution image. In the x-ray range this opens the possibility to overcome the limited numerical aperture of existing x-ray lenses. Furthermore, digital wave front correction (DWC) may be used to charaterize and correct lens imperfections. Given the diffraction limit achievable with x-ray lenses (below 100 nm), x-ray Fourier ptychographic microscopy (XFPM) should be able to reach resolutions in the 10 nm range.

  5. X-ray diffraction: instrumentation and applications.

    Science.gov (United States)

    Bunaciu, Andrei A; Udriştioiu, Elena Gabriela; Aboul-Enein, Hassan Y

    2015-01-01

    X-ray diffraction (XRD) is a powerful nondestructive technique for characterizing crystalline materials. It provides information on structures, phases, preferred crystal orientations (texture), and other structural parameters, such as average grain size, crystallinity, strain, and crystal defects. X-ray diffraction peaks are produced by constructive interference of a monochromatic beam of X-rays scattered at specific angles from each set of lattice planes in a sample. The peak intensities are determined by the distribution of atoms within the lattice. Consequently, the X-ray diffraction pattern is the fingerprint of periodic atomic arrangements in a given material. This review summarizes the scientific trends associated with the rapid development of the technique of X-ray diffraction over the past five years pertaining to the fields of pharmaceuticals, forensic science, geological applications, microelectronics, and glass manufacturing, as well as in corrosion analysis.

  6. X-ray modeling for SMILE

    Science.gov (United States)

    Sun, T.; Wang, C.; Wei, F.; Liu, Z. Q.; Zheng, J.; Yu, X. Z.; Sembay, S.; Branduardi-Raymont, G.

    2016-12-01

    SMILE (Solar wind Magnetosphere Ionosphere Link Explorer) is a novel mission to explore the coupling of the solar wind-magnetosphere-ionosphere system via providing global images of the magnetosphere and aurora. As the X-ray imaging is a brand new technique applied to study the large scale magnetopause, modeling of the solar wind charge exchange (SWCX) X-ray emissions in the magnetosheath and cusps is vital in various aspects: it helps the design of the Soft X-ray Imager (SXI) on SMILE, selection of satellite orbits, as well as the analysis of expected scientific outcomes. Based on the PPMLR-MHD code, we present the simulation results of the X-ray emissions in geospace during storm time. Both the polar orbit and the Molniya orbit are used. From the X-ray images of the magnetosheath and cusps, the magnetospheric responses to an interplanetary shock and IMF southward turning are analyzed.

  7. Electrocoagulation using a rotated anode: A novel reactor design for textile wastewater treatment.

    Science.gov (United States)

    Naje, Ahmed Samir; Chelliapan, Shreeshivadasan; Zakaria, Zuriati; Abbas, Saad A

    2016-07-01

    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.

  8. Probing the clumping structure of Giant Molecular Clouds through the spectrum, polarisation and morphology of X-ray Reflection Nebulae

    CERN Document Server

    Molaro, Margherita; Sunyaev, Rashid

    2015-01-01

    We suggest a method for probing global properties of clump populations in Giant Molecular Clouds (GMCs) in the case where these act as X-ray reflection nebulae (XRNe), based on the study of the clumping's overall effect on the reflected X-ray signal, in particular on the Fe K-alpha line's shoulder. We consider the particular case of Sgr B2, one of the brightest and most massive XRN in our Galaxy. We parametrise the gas distribution inside the cloud using a simple clumping model, with the slope of the clump mass function (alpha), the minimum clump mass (m_{min}), the fraction of the cloud's mass contained in clumps (f_{DGMF}), and the mass-size relation of individual clumps as free parameters, and investigate how these affect the reflected X-ray spectrum. In the case of very dense clumps, similar to those presently observed in Sgr B2, these occupy a small volume of the cloud and present a small projected area to the incoming X-ray radiation. We find that these contribute negligibly to the scattered X-rays. Clu...

  9. X-ray emission from the blazar AO 0235+16: the XMM-Newton and Chandra point of view

    CERN Document Server

    Raiteri, C M; Kadler, M; Krichbaum, T P; Böttcher, M; Fuhrmann, L; Orio, M

    2006-01-01

    In this paper we analyse five observations of the BL Lac object AO 0235+16 performed with the Chandra and XMM-Newton satellites during the years 2000-2005. In the February 2002 observation the source is found in a bright state and presents a steep X-ray spectrum, while in all the other epochs it is faint and the spectrum is hard. The soft X-ray spectrum appears to be strongly absorbed, likely by the intervening system at z=0.524, which also absorbs the optical-UV radiation. We find that models that consider spectral curvature are superior to single power law ones in fitting the X-ray spectrum. In particular, we favour a double power law model, which agrees with the assumption of a superposition of two different components in the X-ray domain. Both in the Chandra and in one of the XMM-Newton observations, a tentative detection of the redshifted Fe Kalpha emission line may suggest its origin from the inner part of an accretion disc. Thermal emission from this accretion disc might explain the UV-soft-X-ray bump ...

  10. Crystallization and preliminary X-ray diffraction analysis of the mitochondrial transcription factor sc-mtTFB from Saccharomyces cerevisiae.

    Science.gov (United States)

    Schubot, F D; Chen, C J; Rose, J P; Wang, B C

    2000-07-01

    Eukaryotic mitochondria contain a distinct mini-chromosome. In yeast, transcription of the mitochondrial genome is mediated by a nuclear-encoded RNA polymerase consisting of a single polypeptide core enzyme and a specificity factor termed sc-mtTFB which bears some similarity to bacterial sigma-factors. sc-mtTFB from Saccharomyces cerevisiae has been cloned, expressed, purified and crystallized. The crystals belong to the monoclinic space group C2, with unit-cell parameters a = 89.7, b = 44.6, c = 98.9 A, beta = 110 degrees. Based on one molecule per asymmetric unit, the solvent content is estimated to be 48%. Small crystals of dimensions 0.01 x 0.05 x 0.13 mm diffract to at least 2.7 A resolution on a rotating-anode X-ray source.

  11. Crystallization and preliminary X-ray studies of mouse centrin1

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Hee [Institut für Medizinische Physik und Biophysik, Charité - Universitätsmedizin Berlin, Ziegelstrasse 5-9, D-10098 Berlin (Germany); Krauss, Norbert [Institut für Biochemie, Charité - Universitätsmedizin Berlin, Monbijoustrasse 2, D-10117 Berlin (Germany); Pulvermüller, Alexander [Institut für Medizinische Physik und Biophysik, Charité - Universitätsmedizin Berlin, Ziegelstrasse 5-9, D-10098 Berlin (Germany); Scheerer, Patrick; Höhne, Wolfgang [Institut für Biochemie, Charité - Universitätsmedizin Berlin, Monbijoustrasse 2, D-10117 Berlin (Germany); Giessl, Andreas; Wolfrum, Uwe [Zell- und Matrixbiologie, Institut für Zoologie, Johannes Gutenberg-Universität Mainz, D-55099 Mainz (Germany); Hofmann, Klaus Peter, E-mail: kph@charite.de; Ernst, Oliver Peter [Institut für Medizinische Physik und Biophysik, Charité - Universitätsmedizin Berlin, Ziegelstrasse 5-9, D-10098 Berlin (Germany); Choe, Hui-Woog, E-mail: kph@charite.de [Institut für Medizinische Physik und Biophysik, Charité - Universitätsmedizin Berlin, Ziegelstrasse 5-9, D-10098 Berlin (Germany); Department of Chemistry, College of Natural Science, Chonbuk National University, 561-756 Chonju (Korea, Republic of)

    2005-05-01

    The expression, purification, crystallization and preliminary X-ray diffraction studies of mouse centrin1 are reported. Centrins belong to a family of Ca{sup 2+}-binding EF-hand proteins that play a fundamental role in centrosome duplication and the function of cilia. To shed light on the structure–function relationship of these proteins, mouse centrin1 has been crystallized. The mouse centrin1 has been expressed in Escherichia coli as a GST-centrin fusion protein containing a thrombin protease cleavage site between the fusion partners. Two constructs with different linking-sequence lengths were expressed and purified. Thrombin cleavage yielded functional centrin1 and N-terminally extended centrin1 containing 25 additional residues upstream of its N-terminus. Only N-terminally extended centrin1 (MW ≃ 22 240 Da) could be crystallized at room temperature, using 20–25%(w/v) PEG 1500, 5–10%(v/v) ethylene glycol and 1–2%(v/v) dioxane. Crystals were suitable for X-ray analysis, diffracting to 2.9 Å at 295 K using a rotating-anode X-ray source. They belong to space group C2, with unit-cell parameters a = 60.7, b = 59.6, c = 58.3 Å, β = 109.4°. Assuming the asymmetric cell to be occupied by one centrin1 molecule of 22.2 kDa, the unit cell contains 45% solvent with a crystal volume per protein weight, V{sub M}, of 2.2 Å{sup 3} Da{sup −1}.

  12. Limit of hydrostaticity in He and Ne determined by means of in situ single crystal x-ray diffraction

    Science.gov (United States)

    Kurnosov, Alexander; Trots, Dmitro; Boffa Balaran, Tiziana; Frost, Daniel

    2010-05-01

    An ultrahigh-intensity rotating anode FR-E+ SuperBright from Rigaku coupled with a Huber four circle diffractometer and VariMaxTM focusing optics has been used to determine accurate and precise lattice parameters of very small single-crystals in diamond anvil cells at pressures above 40 GPa in a conventional laboratory. The optics are focusing the X-ray beam at the sample position (800 mm from the aperture of the optics) to the spot of about 200 μm size with high resolution (as measured by the sharp reflections line widths). The intensities of reflections from any crystal are at least 30 times larger than those obtained for the same sample with a similar x-ray diffractometer equipped with a conventional x-ray tube. However, accurate and precise lattice parameters at high pressure can be obtained only under hydrostatic or at least very close to hydrostatic conditions in order to avoid broadening of the reflections. To test the quasi-hydrostatic limits of He and Ne we have therefore performed a study of single crystals of quartz up to amorphisation of the sample and MgO single crystals. The study of these materials has also the advantage of being able to obtain compare the pressure scale of these two very well known materials with that of the ruby scale which appears to be dependent on the pressure medium used.

  13. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline

    Institute of Scientific and Technical Information of China (English)

    DENG Biao; YANG Qun; XIE Hong-Lan; DU Guo-Hao; XIAO Wi-Qiao

    2011-01-01

    X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF X-ray imaging beamline (BL13W1) are described. The test samples were investigated and the 2D elemental image was reconstructed using a filtered back-projection algorithm. In the sample the element Cd was observed. Up to now, the X-ray fluorescence CT could be carried out at the SSRF X-ray imaging beamline.

  14. Achieving a stable time response in polymeric radiation sensors under charge injection by X-rays.

    Science.gov (United States)

    Intaniwet, Akarin; Mills, Christopher A; Sellin, Paul J; Shkunov, Maxim; Keddie, Joseph L

    2010-06-01

    Existing inorganic materials for radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, lack of tissue-equivalence, toxicity, and mechanical inflexibility. As an alternative to inorganics, poly(triarylamine) (PTAA) diodes have been evaluated for their suitability for detecting radiation via the direct creation of X-ray induced photocurrents. A single layer of PTAA is deposited on indium tin oxide (ITO) substrates, with top electrodes selected from Al, Au, Ni, and Pd. The choice of metal electrode has a pronounced effect on the performance of the device; there is a direct correlation between the diode rectification factor and the metal-PTAA barrier height. A diode with an Al contact shows the highest quality of rectifying junction, and it produces a high X-ray photocurrent (several nA) that is stable during continuous exposure to 50 kV Mo Kalpha X-radiation over long time scales, combined with a high signal-to-noise ratio with fast response times of less than 0.25 s. Diodes with a low band gap, 'Ohmic' contact, such as ITO/PTAA/Au, show a slow transient response. This result can be explained by the build-up of space charge at the metal-PTAA interface, caused by a high level of charge injection due to X-ray-induced carriers. These data provide new insights into the optimum selection of metals for Schottky contacts on organic materials, with wider applications in light sensors and photovoltaic devices.

  15. Variation of the X-ray non-thermal emission in the Arches cloud

    CERN Document Server

    Clavel, Maïca; Terrier, R; Tatischeff, V; Maurin, G; Ponti, G; Goldwurm, A; Decourchelle, A

    2014-01-01

    The origin of the iron fluorescent line at 6.4 keV from an extended region surrounding the Arches cluster is debated and the non-variability of this emission up to 2009 has favored the low-energy cosmic-ray origin over a possible irradiation by hard X-rays. By probing the variability of the Arches cloud non-thermal emission in the most recent years, including a deep observation in 2012, we intend to discriminate between the two competing scenarios. We perform a spectral fit of XMM-Newton observations collected from 2000 to 2013 in order to build the Arches cloud lightcurve corresponding to both the neutral Fe Kalpha line and the X-ray continuum emissions. We reveal a 30% flux drop in 2012, detected with more than 4 sigma significance for both components. This implies that a large fraction of the studied non-thermal emission is due to the reflection of an X-ray transient source.

  16. Modelisation of strains measured by X-ray diffraction in composites with spherical particles

    Energy Technology Data Exchange (ETDEWEB)

    Durand, L.; Lavelle, B.; Drira-Halouani, R.; Altibelli, A. [CNRS, Toulouse (France). CEMES

    2000-07-01

    In a particle composite, elaboration residual stresses have two main origins : differences between thermal expansion coefficients of particles and matrix on the one hand, and volume changes induced by reactions at particles / matrix interface on the other hand. We have compared calculated thermal stresses, and experimental measures on two composites, one presenting an interface reactivity and the other none. The two composites with a nickel matrix and spherical particles either of silica or of alumina have been sintered at 1400 C and analyzed between room temperature and 240 C by X-ray diffraction (Cu K{alpha} radiation). In the semi-infinite composite model, spherical particles have been distributed at the points of a simple cubic lattice. Modelised thickness is larger in comparison of the thickness analyzed by X-ray diffraction. Calculations are based on elastic theory and the difference of coefficients of thermal expansion between the matrix and the particles. Materials are supposed isotropic. At a given temperature, the strain to be observed by X-ray diffraction in a given directions calculated from the distribution of strains in matrix; absorption phenomena are taken into account. Effects of the free surface and of interfacial reactivity are thus shown off. (orig.)

  17. Evolution of the X-ray spectrum in the flare model of Active Galactic Nuclei

    CERN Document Server

    Collin, S; Dumont, A M; Petrucci, P O; Rózanska, A R

    2003-01-01

    Nayakshin & Kazanas (2002) have considered the time-dependent illumination of an accretion disc in Active Galactic Nuclei, in the lamppost model. We extend their study to the flare model, which postulates the release of a large X-ray flux above a small region of the accretion disc. A fundamental difference with the lamppost model is that the region of the disc below the flare is not illuminated before the onset of the flare. A few test models show that the spectrum which follows immediately the increase in continuum flux should display the characteristics of a highly illuminated but dense gas, i.e. very intense X-ray emission lines and ionization edges in the soft X-ray range. The behaviour of the iron line is different in the case of a "moderate" and a ``strong'' flare: for a moderate flare, the spectrum displays a neutral component of the Fe K$\\alpha$ line at 6.4 keV, gradually leading to more highly ionized lines. For a strong flare, the lines are already emitted by FeXXV (around 6.7 keV) after the ons...

  18. Discovery of Red-Skewed K_alpha iron line in Cyg X-2 with Suzaku

    CERN Document Server

    Shaposhnikov, Nikolai; Laurent, Philippe

    2009-01-01

    We report on the Suzaku observation of neutron star low-mass X-ray binary Cygnus X-2 which reveals a presence of the iron K_alpha emission line. The line profile shows a significant red wing. This discovery increases the number of neutron star sources where red-skewed iron lines were observed and strongly suggests that this phenomenon is common not only in black holes but also in other types of accreting compact objects. We examine the line profile in terms of models which attribute its production to the relativistic effects due to reflection of X-ray radiation from a cold accretion disk and also as a result of the line formation in the extended wind/outflow configuration. Both models are able to adequately represent the observed line profile. We consider the results of line modeling in the context of subsecond variability. While we were unable to conclusively disqualify one of the models, we find that the wind paradigm has several advantages over the relativistic disk reflection model.

  19. X-Ray Background from Early Binaries

    Science.gov (United States)

    Kohler, Susanna

    2016-11-01

    What impact did X-rays from the first binary star systems have on the universe around them? A new study suggests this radiation may have played an important role during the reionization of our universe.Ionizing the UniverseDuring the period of reionization, the universe reverted from being neutral (as it was during recombination, the previous period)to once again being ionized plasma a state it has remained in since then. This transition, which occurred between 150 million and one billion years after the Big Bang (redshift of 6 z 20), was caused by the formation of the first objects energetic enough to reionize the universes neutral hydrogen.ROSAT image of the soft X-ray background throughout the universe. The different colors represent different energy bands: 0.25 keV (red), 0.75 keV (green), 1.5 keV (blue). [NASA/ROSAT Project]Understanding this time period in particular, determining what sources caused the reionization, and what the properties were of the gas strewn throughout the universe during this time is necessary for us to be able to correctly interpret cosmological observations.Conveniently, the universe has provided us with an interesting clue: the large-scale, diffuse X-ray background we observe all around us. What produced these X-rays, and what impact did this radiation have on the intergalactic medium long ago?The First BinariesA team of scientists led by Hao Xu (UC San Diego) has suggested that the very first generation of stars might be an important contributor to these X-rays.This hypothetical first generation, Population III stars, are thought to have formed before and during reionization from large clouds of gas containing virtually no metals. Studies suggest that a large fraction of Pop III stars formed in binaries and when those stars ended their lives as black holes, ensuing accretion from their companions could produceX-ray radiation.The evolution with redshift of the mean X-ray background intensities. Each curve represents a different

  20. First Hard X-Ray Detection of the Non-Thermal Emission Around the Arches Cluster: Morphology and Spectral Studies With NuSTAR

    Science.gov (United States)

    Krivonos, Roman A.; Tomsick, John A.; Bauer, Franz E.; Baganoff, Frederick K.; Barriere, Nicolas M.; Bodaghee, Arash; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; Grefenstette, Brian W.; Hailey, Charles J.; Harrison, Fiona A.; Hong, JaeSub; Madsen, Kristin K.; Mori, Kaya; Nynka, Melania; Stern, Daniel; Zhang, William W.

    2014-01-01

    The Arches cluster is a young, densely packed massive star cluster in our Galaxy that shows a high level of star formation activity. The nature of the extended non-thermal X-ray emission around the cluster remains unclear. The observed bright Fe K(alpha) line emission at 6.4 keV from material that is neutral or in a low ionization state can be produced either by X-ray photoionization or by cosmic-ray particle bombardment or both. In this paper, we report on the first detection of the extended emission around the Arches cluster above 10 keV with the NuSTAR mission, and present results on its morphology and spectrum. The spatial distribution of the hard X-ray emission is found to be consistent with the broad region around the cluster where the 6.4 keV line is observed. The interpretation of the hard X-ray emission within the context of the X-ray reflection model puts a strong constraint on the luminosity of the possible illuminating hard X-ray source. The properties of the observed emission are also in broad agreement with the low-energy cosmic-ray proton excitation scenario. Key words: cosmic rays - Galaxy: center - ISM: general - X-rays: individual (Arches cluster)

  1. X-ray in Zeta-Ori

    Science.gov (United States)

    López-García, M. A.; López-Santiago, J. L.; Albacete-Colombo, J. F.; De Castro, E.

    2013-05-01

    Nearby star-forming regions are ideal laboratories to study high-energy emission processes but they usually present high absorption what makes difficult to detect the stellar population inside the molecular complex. As young late-type stars show high X-ray emission and X-ray photons are little absorbed by interstellar material, X-ray dedicated surveys are an excellent tool to detect the low-mass stellar population in optically absorbed regions. In this work, we present a study of the star-forming region Zeta-Ori and its surroundings. We combine optical, infrared and X-ray data. Properties of the X-ray emiting plasma and infrared features of the young stellar objects detected in the XMM-Newton observation are determined. The southern part of the Orion B giant molecular cloud complex harbor other star forming regions, as NGC 2023 and NGC 2024, we use this regions to compare. We study the spectral energy distribution of X-ray sources. Combining these results with infrared, the X-ray sources are classified as class I, class II and class III objects. The X-ray spectrum and ligth curve of detected X-ray sources is analyzed to found flares. We use a extincion-independent index to select the stars with circumstellar disk, and study the relationship between the present of disk and the flare energy. The results are similar to others studies and we conclude that the coronal properties of class II and class III objects in this region do not differ significantly from each other and from stars of similar infrared class in the ONC.

  2. X-ray phase-contrast methods

    Energy Technology Data Exchange (ETDEWEB)

    Lider, V. V., E-mail: lider@ns.crys.ras.ru; Kovalchuk, M. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2013-11-15

    This review is devoted to a comparative description of the methods for forming X-ray phase-contrast images of weakly absorbing (phase) objects. These include the crystal interferometer method, the Talbot interferometer method, diffraction-enhanced X-ray imaging, and the in-line method. The potential of their practical application in various fields of science and technology is discussed. The publications on the development and optimization of X-ray phase-contrast methods and the experimental study of phase objects are analyzed.

  3. Two-dimensional x-ray diffraction

    CERN Document Server

    He, Bob B

    2009-01-01

    Written by one of the pioneers of 2D X-Ray Diffraction, this useful guide covers the fundamentals, experimental methods and applications of two-dimensional x-ray diffraction, including geometry convention, x-ray source and optics, two-dimensional detectors, diffraction data interpretation, and configurations for various applications, such as phase identification, texture, stress, microstructure analysis, crystallinity, thin film analysis and combinatorial screening. Experimental examples in materials research, pharmaceuticals, and forensics are also given. This presents a key resource to resea

  4. A Burst Chasing X-ray Polarimeter

    Science.gov (United States)

    Hill, Joanne

    2007-01-01

    This viewgraph presentation reviews the rationale, design, and importance of an X-Ray Polarimeter. There is a brief discussion of Gamma Ray Bursts, followed by a review of the theories of Gamma-Ray Bursts Polarization. This leads to the question of "How do we measure the polarization?" and a discussion of the GRB x-ray emission, the photoelectric effect and photoelectric polarimetry. The requirements for the work, can only be approached using a gas detector. This leads to a discussion of a Micropattern Gas Polarimeter, and the Time-Projection Chamber (TPC) X-ray Polarimeter.

  5. Speckle Scanning Based X-ray Imaging

    CERN Document Server

    Berujon, Sebastien

    2015-01-01

    The X-ray near field speckle scanning concept is an approach recently introduced to obtain absorption, phase and darkfield images of a sample. In this paper, we demonstrate ways of recovering from a sample its ultra-small angle X-ray scattering distribution using numerical deconvolution, and the 2D phase gradient signal from random step scans, the latter being used to elude the flat field correction error. Each feature is explained theoretically and demonstrated experimentally at a synchrotron X-ray facility.

  6. Soft X-Ray Laser Development

    Science.gov (United States)

    1989-10-01

    AND SUBTrI 5. FUNDING NUMBERS Soft X-ray Laser Development 61102F/2301/A8 L AUTHOR(S) ( Szymon Suckewer 7. PERFORMING ORGANIZATION NAME(S) AND ADORESS...REPORT Report of Progress on Soft X-ray Laser Development submitted to Air Force Office of Scientific Research by Acession For DT!C T.IB Princeton...x-ray laser development by Jaegl6 and coworkers 6, however the present work on aluminium plasmas pumped with a low energy Nd laser was primarily

  7. The Future of X-Ray Optics

    Science.gov (United States)

    Weisskopf, Martin C.

    2013-01-01

    The most important next step is the development of X-ray optics comparable to (or better than) Chandra in angular resolution that far exceed Chandra s effective area. Use the long delay to establish an adequately funded, competitive technology program along the lines I have recommended. Don't be diverted from this objective, except for Explorer-class missions. Progress in X-ray optics, with emphasis on the angular resolution, is central to the paradigm-shifting discoveries and the contributions of X-ray astronomy to multiwavelength astrophysics over the past 51 years.

  8. X-rays from Alpha Centauri

    Science.gov (United States)

    Nugent, J.; Garmire, G.

    1978-01-01

    HEAO 1 observations of soft X-ray emission from a point source in the vicinity of Alpha Cen are reported. The source, designated H1437-61, is tentatively identified with Alpha Cen, and an X-ray luminosity comparable to that of the sun in an active state is estimated. A temperature of about 500,000 K and an emission integral of 5 x 10 to the 50th per cu cm are obtained. Coronal emission is suggested as the X-ray-producing mechanism.

  9. Optics for coherent X-ray applications

    OpenAIRE

    2014-01-01

    Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method w...

  10. Two methods for studying the X-ray variability

    NARCIS (Netherlands)

    Yan, Shu-Ping; Ji, Li; Méndez, Mariano; Wang, Na; Liu, Siming; Li, Xiang-Dong

    2016-01-01

    The X-ray aperiodic variability and quasi-periodic oscillation (QPO) are the important tools to study the structure of the accretion flow of X-ray binaries. However, the origin of the complex X-ray variability from X-ray binaries remains yet unsolved. We proposed two methods for studying the X-ray

  11. High-Resolution X-Ray Spectroscopy of the Galactic Supernova Remnant Puppis A with the XMM-Newton RGS

    Science.gov (United States)

    Katsuda, Satoru; Tsunemi, Hiroshi; Mori, Koji; Uchida, Hiroyuki; Petre, Robert; Yamada, Shinya; Akamatsu, Hiroki; Konami, Saori; Tamagawa, Toru

    2012-01-01

    We present high-resolution X-ray spectra of cloud-shock interaction regions in the eastern and northern rims of the Galactic supernova remnant Puppis A, using the Reflection Grating Spectrometer onboard the XMM-Newton satellite. A number of emission lines including K(alpha) triplets of He-like N, O , and Ne are clearly resolved for the first time. Intensity ratios of forbidden to resonance lines in the triplets are found to be higher than predictions by thermal emission models having plausible plasma parameters. The anomalous line ratios cannot be reproduced by effects of resonance scattering, recombination, or inner-shell ionization processes, but could be explained by charge-exchange emission that should arise at interfaces between the cold/warm clouds and the hot plasma. Our observations thus provide observational support for charge-exchange X-ray emission in supernova remnants.

  12. Guiding and concentrating hard x-rays by using a flexible hollow-core tapered glass fiber.

    Science.gov (United States)

    Thiel, D J; Bilderback, D H; Lewis, A; Stern, E A; Rich, T

    1992-03-01

    A 1.6-m-long, flexible, hollow glass fiber with a gradually diminishing bore diameter has been used efficiently to compress the size of an x-ray beam as it reflects from the inside walls of the fiber by total external reflection. The transmission characteristics of the fiber are reported for monochromatic synchrotron radiation of 8.04, 13, and 20 keV, as well as for CuKalpha radiation from a conventional x-ray tube. Intensity enhancements as large as 10 that correspond to a transmission efficiency of 54% were observed. The high efficiency of this prototype fiber supports the idea that this confinement technique should yield intensity gains of many orders of magnitude as the optimal fiber design is achieved.

  13. Total reflection x-ray fluorescence: Determination of an optimum geometry

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Y.M. [Pohang Univ. of Science and Technology (Korea, Republic of); Chang, C.H.; Padmore, H.A. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    Total reflection X-Ray Fluorescence (TXRF) is a widely used technique in which the normal trace element detection capability of hard x-ray fluorescence (XRF) is enhanced by use of an x-ray reflective substrate. TXRF is more sensitive than normal photon induced XRF due to the reduction of the substrate scattering and fluorescence signals. This reduction comes about because in total external reflection, the photon field only penetrates about 20 {angstrom} into the surface, instead of typically 50 {mu}m for a silicon substrate at normal incidence for 10 KeV photons. The technique is used in many fields of trace element analysis, and is widely used in the determination of metal impurity concentrations on and in the surface of silicon wafers. The Semiconductor Industry Association roadmap (SIA) indicates a need for wafer contamination detection at the 10{sup 7}atoms/cm{sup 2} level in the next few years. Current commercial systems using rotating anode x-ray sources presently routinely operate with a sensitivity level of around 10{sup 10} atoms/cm{sup 2} and this has led to interest in the use of synchrotron radiation to extend the sensitivity by three orders of magnitude. The pioneering work of Pianetta and co-workers at SSRL has clearly shown that this should be possible, using a fully optimized source and detector. The purpose of this work is to determine whether ALS would be a suitable source for this type of highly sensitive wafer TXRF. At first look it appears improbable as the SSRL work used a high flux multipole wiggler source, and it is clear that the detected fluorescence for relevant concentrations is small. In addition, SSRL operates at 3.0 GeV rather than 1.9 GeV, and is therefore more naturally suited to hard x-ray experiments. The aim of this work was therefore to establish a theoretical model for the scattering and fluorescence processes, so that one could predict the differences between alternative geometries and select an optimum configuration.

  14. Grazing Incidence Small Angle X-Ray Scattering: Technique and Application to Discontinuous Thin Films

    Science.gov (United States)

    Levine, Joanne Rachel

    1990-01-01

    During the early stages of thin film growth in many thin film-substrate systems, adsorbate atoms form discrete three-dimensional islands, typically 10 A to 150 A in size. In order to study these islands, surface sensitive small angle x-ray scattering has been done for the first time by using a grazing incidence geometry (GISAXS). In this method, the substrate is aligned for total external reflection and the islands produce small angle scattering from the refracted beam crossing the substrate surface. The motivation for developing the GISAXS technique is the advantages GISAXS offers. First, because GISAXS works in reflection, there are no substrate thickness restrictions. Second, there is no sample conductivity requirement. Third, there are no x-ray beam induced sample changes. Finally, the x-ray beam samples all of the islands in the beam path simultaneously. In order to examine thin films in situ with GISAXS, an ultra-high vacuum chamber has been built which can be attached to a rotating anode or synchrotron x-ray source. This chamber is equipped with a pair of beryllium windows, a metal evaporator, a sample heater, and a precision rotary sample holder feedthrough. The GISAXS technique was applied to a model system of gold islands on glass substrates. The glass provides high reflectivity and gold provides strong atomic number contrast. For as-deposited films from 5 A to 15 A in average thickness, average island sizes, heights, and preferred island spacings, and the island surface roughness were determined. From the results of low temperature (< 375^circK) post-deposition annealing experiments, a model was developed which explains the observed slow time-dependence of post-deposition island growth in terms of overlapping diffusion fields and mass transfer by island mobility. The activation energy for this process was determined to be 0.49 eV. These GISAXS results were supplemented with transmission electron micrographs of and grazing incidence wide angle x-ray

  15. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy.

    Science.gov (United States)

    Miaja-Avila, L; O'Neil, G C; Uhlig, J; Cromer, C L; Dowell, M L; Jimenez, R; Hoover, A S; Silverman, K L; Ullom, J N

    2015-03-01

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼10(6) photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10(7) laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  16. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  17. Milli X-Ray Fluorescence Spectrometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Eagle III Micro XRF unit is similar to a traditional XRF unit, with the primary difference being that the X-rays are focused by a polycapillary optic into a spot...

  18. Silicon Wafer X-ray Mirror Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this one year research project, we propose to do the following four tasks;(1) Design the silicon wafer X-ray mirror demo unit and develop a ray-tracing code to...

  19. Nonrelativistic quantum X-ray physics

    CERN Document Server

    Hau-Riege, Stefan P

    2015-01-01

    Providing a solid theoretical background in photon-matter interaction, Nonrelativistic Quantum X-Ray Physics enables readers to understand experiments performed at XFEL-facilities and x-ray synchrotrons. As a result, after reading this book, scientists and students will be able to outline and perform calculations of some important x-ray-matter interaction processes. Key features of the contents are that the scope reaches beyond the dipole approximation when necessary and that it includes short-pulse interactions. To aid the reader in this transition, some relevant examples are discussed in detail, while non-relativistic quantum electrodynamics help readers to obtain an in-depth understanding of the formalisms and processes. The text presupposes a basic (undergraduate-level) understanding of mechanics, electrodynamics, and quantum mechanics. However, more specialized concepts in these fields are introduced and the reader is directed to appropriate references. While primarily benefiting users of x-ray light-sou...

  20. The Need for X-Ray Spectroscopy

    Science.gov (United States)

    Winebarger, Amy R.; Cirtain, Jonathan; Kobayashi, Ken

    2011-01-01

    For over four decades, X-ray, EUV, and UV spectral observations have been used to measure physical properties of the solar atmosphere. During this time, there has been substantial improvement in the spectral, spatial, and temporal resolution of the observations for the EUV and UV wavelength ranges. At wavelengths below 100 Angstroms, however, observations of the solar corona with simultaneous spatial and spectral resolution are limited, and not since the late 1970's have spatially resolved solar X-ray spectra been measured. The soft-X-ray wavelength range is dominated by emission lines formed at high temperatures and provides diagnostics unavailable in any other wavelength range. In this presentation, we will discuss the important science questions that can be answered using spatially and spectrally resolved X-ray spectra.

  1. Cold X-Ray Impulse Estimates

    Energy Technology Data Exchange (ETDEWEB)

    DiPeso, G.

    2001-03-01

    The purpose of this short note is to document comparisons between a simple analytic model and the BUCKL[1]x-ray deposition and impulse code and to briefly demonstrate the effect of deposition time on impulse.

  2. Demonstration of X-ray talbot interferometry

    CERN Document Server

    Momose, A; Kawamoto, S; Hamaishi, Y; Takai, K; Suzuki, Y

    2003-01-01

    First Talbot interferometry in the hard X-ray region was demonstrated using a pair of transmission gratings made by forming gold stripes on glass plates. By aligning the gratings on the optical axis of X-rays with a separation that caused the Talbot effect by the first grating, moire fringes were produced inclining one grating slightly against the other around the optical axis. A phase object placed in front of the first grating was detected by moire-fringe bending. Using the technique of phase-shifting interferometry, the differential phase corresponding to the phase object could also be measured. This result suggests that X-ray Talbot interferometry is a novel and simple method for phase-sensitive X-ray radiography. (author)

  3. X-ray crystallographic studies of metalloproteins.

    Science.gov (United States)

    Volbeda, Anne

    2014-01-01

    Many proteins require metals for their physiological function. In combination with spectroscopic characterizations, X-ray crystallography is a very powerful method to correlate the function of protein-bound metal sites with their structure. Due to their special X-ray scattering properties, specific metals may be located in metalloprotein structures and eventually used for phasing the diffracted X-rays by the method of Multi-wavelength Anomalous Dispersion (MAD). How this is done is the principle subject of this chapter. Attention is also given to the crystallographic characterization of different oxidation states of redox active metals and to the complication of structural changes that may be induced by X-ray irradiation of protein crystals.

  4. X-ray Emission from Solar Flares

    Indian Academy of Sciences (India)

    Rajmal Jain; Malini Aggarwal; Raghunandan Sharma

    2008-03-01

    Solar X-ray Spectrometer (SOXS), the first space-borne solar astronomy experiment of India was designed to improve our current understanding of X-ray emission from the Sun in general and solar flares in particular. SOXS mission is composed of two solid state detectors, viz., Si and CZT semiconductors capable of observing the full disk Sun in X-ray energy range of 4–56 keV. The X-ray spectra of solar flares obtained by the Si detector in the 4–25 keV range show evidence of Fe and Fe/Ni line emission and multi-thermal plasma. The evolution of the break energy point that separates the thermal and non-thermal processes reveals increase with increasing flare plasma temperature. Small scale flare activities observed by both the detectors are found to be suitable to heat the active region corona; however their location appears to be in the transition region.

  5. Experimental x-ray ghost imaging

    CERN Document Server

    Pelliccia, Daniele; Scheel, Mario; Cantelli, Valentina; Paganin, David M

    2016-01-01

    We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam was correlated with the spatially resolved intensity measured on the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x-rays may open the way to protocols to reduce radiation damage in medical imaging and in non-destructive structural characterization using Free Electron Lasers.

  6. X-ray source for mammography

    Science.gov (United States)

    Logan, Clinton M.

    1994-01-01

    An x-ray source utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms.

  7. Astrophysics: Unexpected X-ray flares

    Science.gov (United States)

    Campana, Sergio

    2016-10-01

    Two sources of highly energetic flares have been discovered in archival X-ray data of 70 nearby galaxies. These flares have an undetermined origin and might represent previously unknown astrophysical phenomena. See Letter p.356

  8. X-ray induced optical reflectivity

    Directory of Open Access Journals (Sweden)

    Stephen M. Durbin

    2012-12-01

    Full Text Available The change in optical reflectivity induced by intense x-ray pulses can now be used to study ultrafast many body responses in solids in the femtosecond time domain. X-ray absorption creates photoelectrons and core level holes subsequently filled by Auger or fluorescence processes, and these excitations ultimately add conduction and valence band carriers that perturb optical reflectivity. Optical absorption associated with band filling and band gap narrowing is shown to explain the basic features found in recent measurements on an insulator (silicon nitride, Si3N4, a semiconductor (gallium arsenide, GaAs, and a metal (gold, Au, obtained with ∼100 fs x-ray pulses at 500-2000 eV and probed with 800 nm laser pulses. In particular GaAs exhibits an abrupt drop in reflectivity, persisting only for a time comparable to the x-ray excitation pulse duration, consistent with prompt band gap narrowing.

  9. Experimental X-Ray Ghost Imaging

    Science.gov (United States)

    Pelliccia, Daniele; Rack, Alexander; Scheel, Mario; Cantelli, Valentina; Paganin, David M.

    2016-09-01

    We report an experimental proof of principle for ghost imaging in the hard-x-ray energy range. We use a synchrotron x-ray beam that is split using a thin crystal in Laue diffraction geometry. With an ultrafast imaging camera, we are able to image x rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam is correlated with the spatially resolved intensity measured in the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x rays may open the way to protocols to reduce radiation damage in medical imaging and in nondestructive structural characterization using free electron lasers.

  10. Center for X-ray Optics (CXRO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Center for X-Ray Optics at Lawrence Berkeley National Laboratory works to further science and technology using short wavelength optical systems and techniques....

  11. Silicon Wafer X-ray Mirror Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this one year research project, we propose to do the following four tasks; (1) Design the silicon wafer X-ray mirror demo unit and develop a ray-tracing code to...

  12. Capillary Optics generate stronger X-rays

    Science.gov (United States)

    1996-01-01

    NASA scientist, in the Space Sciences lab at Marshall, works with capillary optics that generate more intense X-rays than conventional sources. This capability is useful in studying the structure of important proteins.

  13. X-Ray Exam: Cervical Spine

    Science.gov (United States)

    ... the bones in the back of the neck (cervical vertebrae). During the examination, an X-ray machine sends ... or hand. It can detect fractures in the cervical vertebrae or dislocation of the joints between the vertebrae. ...

  14. Tuberculosis, advanced - chest x-rays (image)

    Science.gov (United States)

    Tuberculosis is an infectious disease that causes inflammation, the formation of tubercules and other growths within tissue, ... death. These chest x-rays show advanced pulmonary tuberculosis. There are multiple light areas (opacities) of varying ...

  15. X-ray microtomography in biology

    CERN Document Server

    Mizutani, Ryuta

    2016-01-01

    Progress in high-resolution x-ray microtomography has provided us with a practical approach to determining three-dimensional (3D) structures of opaque samples at micrometer to submicrometer resolution. In this review, we give an introduction to hard x-ray microtomography and its application to the visualization of 3D structures of biological soft tissues. Practical aspects of sample preparation, handling, data collection, 3D reconstruction, and structure analysis are described. Furthermore, different sample contrasting methods are approached in detail. Examples of microtomographic studies are overviewed to present an outline of biological applications of x-ray microtomography. We also provide perspectives of biological microtomography as the convergence of sciences in x-ray optics, biology, and structural analysis.

  16. X-ray spectra of Hercules X-1. I - Iron line fluorescence from a subrelativistic shell

    Science.gov (United States)

    Pravdo, S. H.; Becker, R. H.; Boldt, E. A.; Holt, S. S.; Serlemitsos, P. J.; Swank, J. H.

    1977-01-01

    The X-ray spectrum of Her X-1 was observed in the energy range from 2 to 24 keV from August 29 to September 3, 1975. Emission features are observed near the K-alpha iron-line energy which exhibit both broadening and a double line structure. The total luminosity in these features is about 4 by 10 to the 35th power ergs/s. Iron line fluorescence from an opaque cool (not exceeding 1 million K) shell of material at the Alfven surface provides the necessary luminosity in this feature. The double line structure and the line energy width can be due to Doppler shifts if the shell is forced to corotate with the pulsar at a radius of at least 800 million cm. Implications of this model regarding physical conditions near Her X-1 are discussed.

  17. X-ray scattering from dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    McSherry, D.J

    2000-09-01

    Dense plasmas were studied by probing them with kilovolt x-rays and measuring those scattered at various angles. The Laser-Produced x-ray source emitted Ti He alpha 4.75 keV x-rays. Two different plasma types were explored. The first was created by laser driven shocks on either side of a sample foil consisting of 2 micron Al layer, sandwiched between two 1 micron CH layers. We have observed a peak in the x-ray scattering cross section, indicating diffraction from the plasma. However, the experimentally inferred plasma density, broadly speaking, did not always agree with the hydrodynamic simulation MEDX (A modified version of MEDUSA). The second plasma type that we studied was created by soft x-ray heating on either side of a sample foil, this time consisting of 1 micron layer of Al, sandwiched between two 0.2 micron CH layers. Two foil targets, each consisting of a 0.1 micron thick Au foil mounted on 1 micron of CH, where placed 4 mm from the sample foil. The soft x-rays where produced by laser irradiating these two foil targets. We found that, 0.5 ns after the peak of the laser heating pulses, the measured cross sections more closely matched those simulated using the Thomas Fermi model than the Inferno model. Later in time, at 2 ns, the plasma is approaching a weakly coupled state. This is the first time x-ray scattering cross sections have been measured from dense plasmas generated by radiatively heating both sides of the sample. Moreover, these are absolute values typically within a factor of two of expectation for early x-ray probe times. (author)

  18. X-ray scattering from dense plasmas

    Science.gov (United States)

    McSherry, Declan Joseph

    Dense plasmas were studied by probing them with kilovolt x-rays and measuring those scattered at various angles. The laser produced x-ray source emitted Ti He alpha 4.75 keV x-rays. Two different plasma types were explored. The first was created by laser driven shocks on either side of a sample foil consisting of 2 micron thickness of Al, sandwiched between two 1 micron CH layers. We have observed a peak in the x-ray scattering cross section, indicating diffraction from the plasma. However, the experimentally inferred plasma density, did not always agree broadly with the hydrodynamic simulation MEDX (A modified version of MEDUSA). The second plasma type that we studied was created by soft x-ray heating on either side of a sample foil, this time consisting of 1 micron thickness of Al, sandwiched between two 0.2 micron CH layers. Two foil targets, each consisting of a 0.1 micron thick Au foil mounted on 1 micron of CH, were placed 4 mm from the sample foil. The soft x-rays were produced by laser irradiating these two foil targets. We found that, 0.5 ns after the peak of the laser heating pulses, that the measured cross sections more closely matched those simulated using the Thomas Fermi model than the Inferno model. Later in time, at 2 ns, the plasma is approaching a weakly coupled state. This is the first time x-ray scattering cross sections have been measured from dense plasmas generated by radiatively heating both sides of the sample. Moreover, these are absolute values typically within a factor of two of expectation for early x-ray probe times.

  19. Parametric X-rays at FAST

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Tanaji [Fermilab

    2016-06-01

    We discuss the generation of parametric X-rays (PXR) in the photoinjector at the new FAST facility at Fermilab. Detailed calculations of the intensity spectrum, energy and angular widths and spectral brilliance with a diamond crystal are presented. We also report on expected results with PXR generated while the beam is channeling. The low emittance electron beam makes this facility a promising source for creating brilliant X-rays.

  20. Lacquer polishing of X-ray optics

    Science.gov (United States)

    Catura, R. C.; Joki, E. G.; Roethig, D. T.; Brookover, W. J.

    1987-01-01

    Techniques for polishing figured X-ray optics by a lacquer-coating process are described. This acrylic lacquer coating has been applied with an optical quality of an eighth-wave in red light and very effectively covers surface roughness with spatial wavelengths less than about 0.2 mm. Tungsten films have been deposited on the lacquer coatings to provide highly efficient X-ray reflectivity.

  1. X- rays and matter- the basic interactions

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens

    2008-01-01

    In this introductory article we attempt to provide the theoretical basis for developing the interaction between X-rays and matter, so that one can unravel properties of matter by interpretation of X-ray experiments on samples. We emphasize that we are dealing with the basics, which means that we ...... this article: J. Als-Nielsen, C. R. Physique 9 (2008). Udgivelsesdato: 18 April...

  2. Capacitor discharges, magnetohydrodynamics, X-rays, ultrasonics

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology, Volume 1: Capacitor Discharges - Magnetohydrodynamics - X-Rays - Ultrasonics deals with the theoretical and engineering problems that arise in the capacitor discharge technique.This book discusses the characteristics of dielectric material, symmetrical switch tubes with mercury filling, and compensation conductor forms. The transformed discharge for highest current peaks, ignition transformer for internal combustion engines, and X-ray irradiation of subjects in mechanical motion are also elaborated. This text likewise covers the transformed capacitor discharge in w

  3. X-Ray Emission from Compact Sources

    Energy Technology Data Exchange (ETDEWEB)

    Cominsky, L

    2004-03-23

    This paper presents a review of the physical parameters of neutron stars and black holes that have been derived from X-ray observations. I then explain how these physical parameters can be used to learn about the extreme conditions occurring in regions of strong gravity, and present some recent evidence for relativistic effects seen in these systems. A glossary of commonly used terms and a short tutorial on the names of X-ray sources are also included.

  4. Spectroscopy in X-ray astronomy

    Science.gov (United States)

    Andresen, R.

    1981-01-01

    Detailed features in cosmic X-ray sources and their associated temporal variation over a wide energy range were studied. Excess emission and absorption at approximately 6 to 7 kiloelectron volts in the spectra of supernova remnants, binary X-ray sources, and clusters of galaxies were observed. A gas scintillation proportional counter (GSPC) will be used as the detector system. In the gas scintillator the principal limitation is due to the statistics of the initial ionization process only.

  5. X-ray induced optical reflectivity

    OpenAIRE

    2012-01-01

    The change in optical reflectivity induced by intense x-ray pulses can now be used to study ultrafast many body responses in solids in the femtosecond time domain. X-ray absorption creates photoelectrons and core level holes subsequently filled by Auger or fluorescence processes, and these excitations ultimately add conduction and valence band carriers that perturb optical reflectivity. Optical absorption associated with band filling and band gap narrowing is shown to explain the basic featur...

  6. Globular cluster x-ray sources.

    Science.gov (United States)

    Pooley, David

    2010-04-20

    Globular clusters and x-ray astronomy have a long and fruitful history. Uhuru and OSO-7 revealed highly luminous (> 10(36) ergs(-1)) x-ray sources in globular clusters, and Einstein and ROSAT revealed a larger population of low-luminosity (luminosity sources were low-mass x-ray binaries in outburst and that they were orders of magnitude more abundant per unit mass in globular clusters than in the rest of the galaxy. However, the low-luminosity sources proved difficult to classify. Many ideas were put forth--low-mass x-ray binaries in quiescence (qLMXBs), cataclysmic variables (CVs), active main-sequence binaries (ABs), and millisecond pulsars (MSPs)--but secure identifications were scarce. In ROSAT observations of 55 clusters, about 25 low-luminosity sources were found. Chandra has now observed over 80 Galactic globular clusters, and these observations have revealed over 1,500 x-ray sources. The superb angular resolution has allowed for many counterpart identifications, providing clues to the nature of this population. It is a heterogeneous mix of qLMXBs, CVs, ABs, and MSPs, and it has been shown that the qLMXBs and CVs are both, in part, overabundant like the luminous LMXBs. The number of x-ray sources in a cluster correlates very well with its encounter frequency. This points to dynamical formation scenarios for the x-ray sources and shows them to be excellent tracers of the complicated internal dynamics. The relation between the encounter frequency and the number of x-ray sources has been used to suggest that we have misunderstood the dynamical states of globular clusters.

  7. Globular cluster x-ray sources

    Science.gov (United States)

    Pooley, David

    2010-01-01

    Globular clusters and x-ray astronomy have a long and fruitful history. Uhuru and OSO-7 revealed highly luminous (> 1036 ergs-1) x-ray sources in globular clusters, and Einstein and ROSAT revealed a larger population of low-luminosity (luminosity sources were low-mass x-ray binaries in outburst and that they were orders of magnitude more abundant per unit mass in globular clusters than in the rest of the galaxy. However, the low-luminosity sources proved difficult to classify. Many ideas were put forth—low-mass x-ray binaries in quiescence (qLMXBs), cataclysmic variables (CVs), active main-sequence binaries (ABs), and millisecond pulsars (MSPs)—but secure identifications were scarce. In ROSAT observations of 55 clusters, about 25 low-luminosity sources were found. Chandra has now observed over 80 Galactic globular clusters, and these observations have revealed over 1,500 x-ray sources. The superb angular resolution has allowed for many counterpart identifications, providing clues to the nature of this population. It is a heterogeneous mix of qLMXBs, CVs, ABs, and MSPs, and it has been shown that the qLMXBs and CVs are both, in part, overabundant like the luminous LMXBs. The number of x-ray sources in a cluster correlates very well with its encounter frequency. This points to dynamical formation scenarios for the x-ray sources and shows them to be excellent tracers of the complicated internal dynamics. The relation between the encounter frequency and the number of x-ray sources has been used to suggest that we have misunderstood the dynamical states of globular clusters. PMID:20404204

  8. X-ray Emission of Hollow Atoms

    Institute of Scientific and Technical Information of China (English)

    ZhaoYongtao; XiaoGuoqing; ZhangXiaoan; YangZhihu; ChenXimeng; ZhangYanping

    2003-01-01

    We have systematically investigated the X-rays emission of hollow atoms (HA) which formed in the interaction of highly charged ions with a variety of solid surfaces at the atomic physics experimental setup of IMP. The X-ray spectra were measured by Si(Li) detectors with effective energy ranging from 1 keV to 60 keV. The results show that, the X-ray emission from the formed HA is closely correlated with the charge state of the projectile ions, and weakly correlated with the velocity of the projectile ions. For example, it was found that when Ar18+ ions interact with Be-target, the yield of K X-ray with character energy of 3.0 keV is 7.2×10-3 per ion, which is two times and 5 order of magnitude higher than those in the interactions of Ar17+ and Ar16+ ions respectively. When Ar15+ ions interact with the same targets, the Argon K X-ray would be too feeble to be detected. The X-ray yield with single ion in this experiment can be represented by the following equation,

  9. Coherence in X-ray physics.

    Science.gov (United States)

    Lengeler, B

    2001-06-01

    Highly brilliant synchrotron radiation sources have opened up the possibility of using coherent X-rays in spectroscopy and imaging. Coherent X-rays are characterized by a large lateral coherence length. Speckle spectroscopy is extended to hard X-rays, improving the resolution to the nm range. It has become possible to image opaque objects in phase contrast with a sensitivity far superior to imaging in absorption contrast. All the currently available X-ray sources are chaotic sources. Their characterization in terms of coherence functions of the first and second order is introduced. The concept of coherence volume, defined in quantum optics terms, is generalized for scattering experiments. When the illuminated sample volume is smaller than the coherence volume, the individuality of the defect arrangement in a sample shows up as speckle in the scattered intensity. Otherwise, a configurational average washes out the speckle and only diffuse scattering and possibly Bragg reflections will survive. The loss of interference due to the finite detection time, to the finite detector pixel size and to uncontrolled degrees of freedom in the sample is discussed at length. A comparison between X-ray scattering, neutron scattering and mesoscopic electron transport is given. A few examples illustrate the possibilities of coherent X-rays for imaging and intensity correlation spectroscopy.

  10. Optics Developments for X-Ray Astronomy

    Science.gov (United States)

    Ramsey, Brian

    2014-01-01

    X-ray optics has revolutionized x-ray astronomy. The degree of background suppression that these afford, have led to a tremendous increase in sensitivity. The current Chandra observatory has the same collecting area (approx. 10(exp 3)sq cm) as the non-imaging UHURU observatory, the first x-ray observatory which launched in 1970, but has 5 orders of magnitude more sensitivity due to its focusing optics. In addition, its 0.5 arcsec angular resolution has revealed a wealth of structure in many cosmic x-ray sources. The Chandra observatory achieved its resolution by using relatively thick pieces of Zerodur glass, which were meticulously figured and polished to form the four-shell nested array. The resulting optical assembly weighed around 1600 kg, and cost approximately $0.5B. The challenge for future x-ray astronomy missions is to greatly increase the collecting area (by one or more orders of magnitude) while maintaining high angular resolution, and all within realistic mass and budget constraints. A review of the current status of US optics for x-ray astronomy will be provided along with the challenges for future developments.

  11. Elliptical X-Ray Spot Measurement

    CERN Document Server

    Richardson, R A; Weir, J T; Richardson, Roger A.; Sampayan, Stephen; Weir, John T.

    2000-01-01

    The so-called roll bar measurement uses a heavy metal material, optically thick to x-rays, to form a shadow of the x-ray origination spot. This spot is where an energetic electron beam interacts with a high Z target. The material (the "roll bar") is slightly curved to avoid alignment problems. The roll bar is constructed and positioned so that the x-rays are shadowed in the horizontal and vertical directions, so information is obtained in two dimensions. If a beam profile is assumed (or measured by other means), the equivalent x-ray spot size can be calculated from the x-ray shadow cast by the roll bar. Thus the ellipticity of the beam can be calculated, assuming the ellipse of the x-ray spot is aligned with the roll bar. The data is recorded using a scintillator and gated camera. Data will be presented from measurements using the ETA II induction LINAC. The accuracy of the measurement is checked using small elliptical targets.

  12. The X-ray imager on AXO

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.; Westergaard, N. J.; Jonasson, P.; Reglero, V.; Eyles, C.

    2001-02-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20×40 cm 2 CZT detector array covering an energy range from 5 to 200 keV.

  13. Echoes in X-ray Binaries

    CERN Document Server

    O'Brien, K; Hynes, R; Chen, W; Haswell, C; Still, M

    2002-01-01

    We present a method of analysing the correlated X-ray and optical/UV variability in X-ray binaries, using the observed time delays between the X-ray driving lightcurves and their reprocessed optical echoes. This allows us to determine the distribution of reprocessing sites within the binary. We model the time-delay transfer functions by simulating the distribution of reprocessing regions, using geometrical and binary parameters. We construct best-fit time-delay transfer functions, showing the regions in the binary responsible for the reprocessing of X-rays. We have applied this model to observations of the Soft X-ray Transient, GRO j1655-40. We find the optical variability lags the X-ray variability with a mean time delay of 19.3$pm{2.2}$ seconds. This means that the outer regions of the accretion disc are the dominant reprocessing site in this system. On fitting the data to a simple geometric model, we derive a best-fit disk half-opening angle of 13.5$^{+2.1}_{-2.8}$ degrees, which is similar to that observe...

  14. The SAS-3 X-ray observatory

    Science.gov (United States)

    Mayer, W. F.

    1975-01-01

    The experiment section of the Small Astronomy Satellite-3 (SAS-3) launched in May 1975 is an X-ray observatory intended to determine the location of bright X-ray sources to an accuracy of 15 arc-seconds; to study a selected set of sources over a wide energy range, from 0.1 to 55 keV, while performing very specific measurements of the spectra and time variability of known X-ray sources; and to monitor the sky continuously for X-ray novae, flares, and unexpected phenomena. The improvements in SAS-3 spacecraft include a clock accurate to 1 part in 10 billion, rotatable solar panels, a programmable data format, and improved nutation damper, a delayed command system, improved magnetic trim and azimuth control systems. These improvements enable SAS-3 to perform three-axis stabilized observations of any point on the celestial sphere at any time of the year. The description of the experiment section and the SAS-3 operation is followed by a synopsis of scientific results obtained from the observations of X-ray sources, such as Vela X-1 (supposed to be an accreting neutron star), a transient source of hard X-ray (less than 36 min in duration) detected by SAS-3, the Crab Nebula pulsar, the Perseus cluster of galaxies, and the Vela supernova remnant.

  15. Optics for coherent X-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Yabashi, Makina, E-mail: yabashi@spring8.or.jp [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Tono, Kensuke [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Mimura, Hidekazu [The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan); Matsuyama, Satoshi; Yamauchi, Kazuto [Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan); Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Ohashi, Haruhiko; Goto, Shunji [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Ishikawa, Tetsuya [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan)

    2014-08-27

    Developments of optics for coherent X-ray applications and their role in diffraction-limited storage rings are described. Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed.

  16. Improved hard x-ray (50-80 keV) imaging of hohlraum implosion experiments at the National Ignition Facility

    Science.gov (United States)

    Bachmann, B.; Chow, R.; Palmer, N. E.; Hoover, M.; Huffman, E.; Lee, J. J.; Romano, E.; Kumar, C.; Hulbert, R. D.; Albert, F.; Dewald, E. L.; Divol, L.; Hohenberger, M.; Landen, O. L.; Warrick, A.; Döppner, T.

    2016-09-01

    We recently designed, built and commissioned a new pinhole / filter assembly for the equatorial hard x-ray imager (eHXI) at the National Ignition Facility (NIF). In this paper we describe the design and metrology of the new diagnostic as well as the spectral and spatial response of the hard x-ray detector. The new eHXI assembly has improved the photon collection efficiency along with spectral and spatial resolution by making use of 1D imaging channels and various hard x-ray filters. In addition we added a Ross pair filter set for Au K-alpha emission (67-69 keV). The new eHXI design will improve our understanding of the sourcing of hot electrons, generated in laser-plasma-instabilities, along the vertical hohlraum axis. This information is an important input for simulating and eventually limiting the DT fuel preheat in ICF implosions.

  17. X-ray and electron generation in the relativistic lambda-cubed regime

    Science.gov (United States)

    Mordovanakis, Aghapi G.

    Over the last two decades, laser-plasma interactions at relativistic intensities have been carried out using large laser facilities producing at least several hundred millijoule pulses at a repetition rate of 10 Hz or lower. A less explored regime is when intensities in excess of 1018 W/cm2 are attained by focusing millijoule-level femtosecond pulses to a spot with a diameter comparable to the laser wavelength. This so-called relativistic lambda3 regime allows the study of certain laser-plasma experiments at kilohertz repetition rate. The present dissertation contributes to the understanding of the x-ray source and hot electrons produced in this regime. The micron-sized lambda3 focus engenders a comparably sized x-ray source that could be attractive for high resolution x-ray imaging applications. With this in mind, the source size is measured for various target materials using the knife-edge technique. Furthermore, the source spatial coherence properties are investigated by analyzing the diffraction pattern off a straight edge. Also investigated are the spatial and energy distributions of hot electrons escaping the plasma. In the case of an Al plasma, the electrons have a Maxwellian-like energy distribution with a temperature that scales with (I lambda 2)0.6 in the 1017--2 x 10 18 W/cm2 intensity range. On the other hand, in the case of an SiO2 plasma with lambda/2 scale-length, the electrons are emitted in a collimated relativistic jet having a non-Maxwellian distribution with = 675 keV. This is the first demonstration of laser-generated relativistic electron beams at kilohertz repetition rate. Additionally, this dissertation reports on two pioneering demonstrations in a related but fundamentally different regime, that of high-average power fiber lasers. In the first experiment, Ni Kalpha x-rays are produced using a fiber CPA system at the intensity of 2 x 1018 W/cm 2, the highest reported to date from a fiber system. The conversion efficiency into the Kalpha

  18. High-resolution spectroscopic diagnostics of very high-temperature plasmas in the hard x-ray regime

    Energy Technology Data Exchange (ETDEWEB)

    Widmann, K

    1999-12-06

    Motivated by the need for establishing a reliable database useful for the application of x-ray spectroscopic tools for the diagnostic of very high temperature plasmas, high-resolution crystal spectrometer measurements have been performed investigating the characteristic K-shell radiation of highly charged krypton and xenon. The measurements, which have been performed at the Electron-Beam-Ion-Trap (EBIT) facility of the Lawrence Livermore National Laboratory, include the investigation of the n = 2 {yields} 1 transitions in heliumlike krypton (Kr{sup 34+}) and innershell excited lithiumlike krypton (Kr{sup 33+}) utilizing a conventional reflection-type crystal spectrometer of von Hamos geometry. The electron-excitation-energy selective measurements map the contribution of the dielectronic recombination lines providing the means of accurate interpretation of the line profiles of the characteristic K{alpha} x-ray emission of plasmas. The high-resolution measurements of the n = 2 {yields} 1 transitions in heliumlike xenon (Xe{sup 52+}) and hydrogenlike xenon (Xe{sup 53+}) were based on a new transmission-type crystal spectrometer of DuMond geometry. The resolving power of the developed spectrometer was sufficient for charge state specific observation allowing the determination of the electron-impact excitation cross section for the hydrogen- and heliumlike K{alpha} transitions. The disagreement with theoretically predicted values is a measure of the magnitude of the Breit interaction for the highly charged high-Z ions.

  19. On the Detectability of Oxygen X-ray Fluorescence and its Use as a Solar Photospheric Abundance Diagnostic

    CERN Document Server

    Drake, Jeremy J

    2008-01-01

    Monte Carlo calculations of the O Kalpha line fluoresced by coronal X-rays and emitted just above the temperature minimum region of the solar atmosphere have been employed to investigate the use of this feature as an abundance diagnostic. While quite weak, we estimate line equivalent widths in the range 0.02-0.2 AA, depending on the X-ray plasma temperature. The line remains essentially uncontaminated by blends for coronal temperatures T =~ 2 ph/s/arcmin^2. Model calculations for solar chemical mixtures with an O abundance adjusted up and down by a factor of 2 indicate 35-60% changes in O Kalpha line equivalent width, providing a potentially useful O abundance diagnostic. Sensitivity of equivalent width to differences between recently recommended chemical compositions with ``high'' and ``low'' complements of the CNO trio important for interpreting helioseismological observations is less accute, amounting to 20-26% at coronal temperatures T ~= 1000 and suitably well-behaved instrumental profile can be built, X...

  20. A Monte Carlo study of x-ray fluorescence in x-ray detectors.

    Science.gov (United States)

    Boone, J M; Seibert, J A; Sabol, J M; Tecotzky, M

    1999-06-01

    Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surface of the screen to reach the photoreceptor. Direct detector systems based on selenium have also enjoyed a growing interest, both commercially and academically. Monte Carlo simulation techniques were used to study the x-ray scattering (Rayleigh and Compton) and the more prevalent x-ray fluorescence properties of seven different x-ray detector materials, Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2. The redistribution of x-ray energy, back towards the x-ray source, in a forward direction through the detector, and lateral reabsorption in the detector was computed under monoenergetic conditions (1 keV to 130 keV by 1 keV intervals) with five detector thicknesses, 30, 60, 90, 120, and 150 mg/cm2 (Se was studied from 30 to 1000 mg/cm2). The radial distribution (related to the point spread function) of reabsorbed x-ray energy was also determined. Representative results are as follows: At 55 keV, more (31.3%) of the incident x-ray energy escaped from a 90 mg/cm2Gd2O2S detector than was absorbed (27.9%). Approximately 1% of the total absorbed energy was reabsorbed greater than 0.5 mm from the primary interaction, for 90 mg/cm2 CsI exposed at 100 kVp. The ratio of reabsorbed secondary (fluorescence + scatter) radiation to the primary radiation absorbed in the detectors (90 mg/cm2) (S/P) was determined as 10%, 16%, 2%, 12%, 3%, 3%, and 0.3% for a 100 kVp tungsten anode x-ray spectrum, for the Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2 detectors, respectively. The results indicate significant x-ray fluorescent escape and reabsorption in common x-ray detectors. These findings

  1. Laser-based X-ray and electron source for X-ray fluorescence studies

    Science.gov (United States)

    Valle Brozas, F.; Crego, A.; Roso, L.; Peralta Conde, A.

    2016-08-01

    In this work, we present a modification to conventional X-rays fluorescence using electrons as excitation source and compare it with the traditional X-ray excitation for the study of pigments. For this purpose, we have constructed a laser-based source capable to produce X-rays as well as electrons. Because of the large penetration depth of X-rays, the collected fluorescence signal is a combination of several material layers of the artwork under study. However, electrons are stopped in the first layers, allowing a more superficial analysis. We show that the combination of both excitation sources can provide extremely valuable information about the structure of the artwork.

  2. Handbook of X-Ray Astronomy

    Science.gov (United States)

    Arnaud, Keith A. (Editor); Smith, Randall K.; Siemiginowska, Aneta

    2011-01-01

    X-ray astronomy was born in the aftermath of World War II as military rockets were repurposed to lift radiation detectors above the atmosphere for a few minutes at a time. These early flights detected and studied X-ray emission from the Solar corona. The first sources beyond the Solar System were detected during a rocket flight in 1962 by a team headed by Riccardo Giaccom at American Science and Engineering, a company founded by physicists from MIT. The rocket used Geiger counters with a system designed to reduce non-X-ray backgrounds and collimators limiting the region of sky seen by the counters. As the rocket spun, the field of view (FOV) happened to pass over what was later found to be the brightest non-Solar X-ray source; later designated See X-1. It also detected a uniform background glow which could not be resolved into individual sources. A follow-up campaign using X-ray detectors with better spatial resolution and optical telescopes identified See X-1 as an interacting binary with a compact (neutron star) primary. This success led to further suborbital rocket flights by a number of groups. More X-ray binaries were discovered, as well as X-ray emission from supernova remnants, the radio galaxies M87 and Cygnus-A, and the Coma cluster. Detectors were improved and Geiger counters were replaced by proportional counters, which provided information about energy spectra of the sources. A constant challenge was determining precise positions of sources as only collimators were available.

  3. Low energy x-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.R.

    1981-06-05

    A subkilovolt spectrometer has been produced to permit high-energy-resolution, time-dependent x-ray intensity measurements. The diffracting element is a curved mica (d = 9.95A) crystal. To preclude higher order (n > 1) diffractions, a carbon x-ray mirror that reflects only photons with energies less than approx. 1.1 keV is utilized ahead of the diffracting element. The nominal energy range of interest is 800 to 900 eV. The diffracted photons are detected by a gold-surface photoelectric diode designed to have a very good frequency response, and whose current is recorded on an oscilloscope. A thin, aluminium light barrier is placed between the diffracting crystal and the photoelectric diode detector to keep any uv generated on or scattered by the crystal from illuminating the detector. High spectral energy resolution is provided by many photocathodes between 8- and 50-eV wide placed serially along the diffracted x-ray beam at the detector position. The spectrometer was calibrated for energy and energy dispersion using the Ni L..cap alpha../sub 1/ /sub 2/ lines produced in the LLNL IONAC accelerator and in third order using a molybdenum target x-ray tube. For the latter calibration the carbon mirror was replaced by one surfaced with rhodium to raise the cut-off energy to about 3 keV. The carbon mirror reflection dependence on energy was measured using one of our Henke x-ray sources. The curved mica crystal diffraction efficiency was measured on our Low-Energy x-ray (LEX) machine. The spectrometer performs well although some changes in the way the x-ray mirror is held are desirable. 16 figures.

  4. Discovery of the Red-Skewed K-alpha Iron Line in Cyg X-2 with Suzaku

    Science.gov (United States)

    Shaposhnikov, Nikolai; Titarchuk, Lev; Laurent, Philippe

    2008-01-01

    We report on the Suzaku observation of neutron star low-mass X-ray binary Cygnus X-2 which reveals strong iron K-alpha emission line. The line profile shows a prominent red wing extending down to 4 keV. This discovery increases the number of neutron star sources where red-skewed iron lines were observed and strongly suggests that this phenomenon is common not only in black holes but also in other types of compact objects. We examine the line profile by fitting it with the model which attributes its production to the relativistic effects due to disk reflection of X-ray radiation. We also apply an alternative model where the red wing is a result of down-scattering effect of the first order with respect to electron velocity in the wind outflow. Both models describe adequately the observed line profile. However, the X-ray variability in a state similar to that in the Suzaku observation which we establish by analysing RXTE observation favors the wind origin of the line formation.

  5. A point-focusing small angle x-ray scattering camera using a doubly curved monochromator of a W/Si multilayer

    Science.gov (United States)

    Sasanuma, Yuji; Law, Robert V.; Kobayashi, Yuji

    1996-03-01

    A point-focusing small angle x-ray scattering (SAXS) camera using a doubly curved monochromator of a W/Si multilayer has been designed, constructed, and tested. The two radii of curvature of the monochromator are 20 400 and 7.6 mm. The reflectivity of its first-order Bragg reflection for CuKα radiation was calculated to be 0.82, being comparable to that (0.81) of its total reflection. By only 10 s x-ray exposure, scattering from a high-density polyethylene film was detected on an imaging plate (IP). A rotating-anode x-ray generator operated at 40 kV and 30 mA was used. Diffraction from rat-tail collagen has shown that the optical arrangement gives the Bragg spacing up to, at least, 30 nm for CuKα radiation. Combined with IPs, the camera may permit us to carry out time-resolved SAXS measurements for phase behaviors of liquid crystals, lipids, polymer alloys, etc., on conventional x-ray generators available in laboratories.

  6. New achievements in X-ray optics——the X-ray lens and its applications

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    An X-ray lens consists of a large number of X-ray capillaries. It can collect divergent X-rays emitted from an X-ray source and form a focused or parallel beam of high intensity. So it is an effective tool for adjusting and controlling wide bandwidth X-ray beams. In this paper, the X-ray lens made by the X-ray Optics Laboratory of Institute of Low Energy Nuclear Physics at Beijing Normal University and its applications in the field of X-ray analysis are presented.

  7. X-ray diffraction contrast tomography (DCT) system, and an X-ray diffraction contrast tomography (DCT) method

    DEFF Research Database (Denmark)

    2012-01-01

    Source: US2012008736A An X-ray diffraction contrast tomography system (DCT) comprising a laboratory X-ray source (2), a staging device (5) rotating a polycrystalline material sample in the direct path of the X-ray beam, a first X-ray detector (6) detecting the direct X-ray beam being transmitted...... through the crystalline material sample, a second X-ray detector (7) positioned between the staging device and the first X-ray detector for detecting diffracted X-ray beams, and a processing device (15) for analysing detected values. The crystallographic grain orientation of the individual grain...

  8. X-Ray Calorimeter Arrays for Astrophysics

    Science.gov (United States)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  9. The weak neutral Fe fluorescence line and long-term X-ray evolution of the Compton-thick AGN in NGC 7674

    CERN Document Server

    Gandhi, P; Lansbury, G B; Stern, D; Alexander, D M; Bauer, F E; Bianchi, S; Boggs, S E; Boorman, P G; Brandt, W N; Brightman, M; Christensen, F E; Comastri, A; Craig, W W; Del Moro, A; Elvis, M; Guainazzi, M; Hailey, C J; Harrison, F A; Koss, M; Lamperti, I; Malaguti, G; Masini, A; Matt, G; Puccetti, S; Ricci, C; Rivers, E; Walton, D J; Zhang, W W

    2016-01-01

    We present NuSTAR X-ray observations of the active galactic nucleus (AGN) in NGC 7674. The source shows a flat X-ray spectrum, suggesting that it is obscured by Compton-thick gas columns. Based upon long-term flux dimming, previous work suggested the alternate possibility that the source is a recently switched-off AGN with the observed X-rays being the lagged echo from the torus. Our high-quality data show the source to be reflection-dominated in hard X-rays, but with a relatively weak neutral Fe Kalpha emission line (equivalent width [EW] of ~0.4 keV) and a strong Fe XXVI ionised line (EW~0.2 keV). We construct an X-ray light curve of NGC 7674 spanning 37 years and find that the observed 2-10 keV X-ray flux has remained constant for the past ~20 years. Light travel time arguments constrain the minimum radius of the reflector to be ~3.2 pc under the switched-off AGN scenario, ~30x larger than the expected dust sublimation radius, rendering this possibility unlikely. A combination of intrinsic fading and patch...

  10. First hard X-ray detection of the non-thermal emission around the Arches cluster: morphology and spectral studies with NuSTAR

    CERN Document Server

    Krivonos, Roman A; Bauer, Franz E; Baganoff, Frederick K; Barriere, Nicolas M; Bodaghee, Arash; Boggs, Steven E; Christensen, Finn E; Craig, William W; Grefenstette, Brian W; Hailey, Charles J; Harrison, Fiona A; Hong, JaeSub; Madsen, Kristin K; Mori, Kaya; Nynka, Melania; Stern, Daniel; Zhang, William W

    2013-01-01

    The Arches cluster is a young, densely packed massive star cluster in our Galaxy that shows a high level of star formation activity. The nature of the extended non-thermal X-ray emission around the cluster remains unclear. The observed bright Fe K_alpha line emission at 6.4 keV from material that is neutral or in a low ionization state can be produced either by X-ray photoionization or by cosmic-ray particle bombardment or both. In this paper we report on the first detection of the extended emission around the Arches cluster above 10 keV with the NuSTAR mission, and present results on its morphology and spectrum. The spatial distribution of the hard X-ray emission is found to be consistent with the broad region around the cluster where the 6.4 keV line is observed. The interpretation of the hard X-ray emission within the context of the X-ray reflection model puts a strong constraint on the luminosity of the possible illuminating hard X-ray source. The properties of the observed emission are also in broad agre...

  11. Ultrafast X-Ray Coherent Control

    Energy Technology Data Exchange (ETDEWEB)

    Reis, David

    2009-05-01

    This main purpose of this grant was to develop the nascent eld of ultrafast x-ray science using accelerator-based sources, and originally developed from an idea that a laser could modulate the di racting properties of a x-ray di racting crystal on a fast enough time scale to switch out in time a shorter slice from the already short x-ray pulses from a synchrotron. The research was carried out primarily at the Advanced Photon Source (APS) sector 7 at Argonne National Laboratory and the Sub-Picosecond Pulse Source (SPPS) at SLAC; in anticipation of the Linac Coherent Light Source (LCLS) x-ray free electron laser that became operational in 2009 at SLAC (all National User Facilities operated by BES). The research centered on the generation, control and measurement of atomic-scale dynamics in atomic, molecular optical and condensed matter systems with temporal and spatial resolution . It helped develop the ultrafast physics, techniques and scienti c case for using the unprecedented characteristics of the LCLS. The project has been very successful with results have been disseminated widely and in top journals, have been well cited in the eld, and have laid the foundation for many experiments being performed on the LCLS, the world's rst hard x-ray free electron laser.

  12. X-ray spectroscopy an introduction

    CERN Document Server

    Agarwal, Bipin K

    1979-01-01

    Rontgen's discovery of X-rays in 1895 launched a subject which became central to the development of modern physics. The verification of many of the predic­ tions of quantum theory by X-ray spectroscopy in the early part of the twen­ tieth century stimulated great interest in thi's area, which has subsequently influenced fields as diverse as chemical physics, nuclear physics, and the study of the electronic properties of solids, and led to the development of techniques such as Auger, Raman, and X-ray photoelectron spectroscopy. The improvement of the theoretical understanding of the physics underlying X-ray spectroscopy has been accompanied by advances in experimental techniques, and the subject provides an instructive example of how progress on both these fronts can be mutually beneficial. This book strikes a balance between his­ torical description, which illustrates this symbiosis, and the discussion of new developments. The application of X-ray spectroscopic methods to the in­ vestigation of chemical b...

  13. Ultrafast X-ray pulse measurement method

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni

    2010-01-01

    In this paper we describe a measurement technique capable of resolving femtosecond X-ray pulses from XFEL facilities. Since these ultrashort pulses are themselves the shortest event available, our measurement strategy is to let the X-ray pulse sample itself. Our method relies on the application of a "fresh" bunch technique, which allows for the production of a seeded X-ray pulse with a variable delay between seed and electron bunch. The shot-to-shot averaged energy per pulse is recorded. It turns out that one actually measures the autocorrelation function of the X-ray pulse, which is related in a simple way to the actual pulse width. For implementation of the proposed technique, it is sufficient to substitute a single undulator segment with a short magnetic chicane. The focusing system of the undulator remains untouched, and the installation does not perturb the baseline mode of operation. We present a feasibility study and we make exemplifications with typical parameters of an X-ray FEL.

  14. Imaging in Hard X-ray Astronomy

    CERN Document Server

    Li Ti Pei

    2002-01-01

    The energy range of hard X-rays is a key waveband to the study of high energy processes in celestial objects, but still remains poorly explored. In contrast to direct imaging methods used in the low energy X-ray and high energy gamma-ray bands, currently imaging in the hard X-ray band is mainly achieved through various modulation techniques. A new inversion technique, the direct demodulation method, has been developed since early 90s. With this technique, wide field and high resolution images can be derived from scanning data of a simple collimated detector. The feasibility of this technique has been confirmed by experiment, balloon-borne observation and analyzing simulated and real astronomical data. Based the development of methodology and instrumentation, a high energy astrophysics mission -- Hard X-ray Modulation Telescope (HXMT) has been proposed and selected in China for a four-year Phase-A study. The main scientific objectives are a full-sky hard X-ray (20-200 keV) imaging survey and high signal-to-noi...

  15. Nonlinear X-ray Compton Scattering

    CERN Document Server

    Fuchs, Matthias; Chen, Jian; Ghimire, Shambhu; Shwartz, Sharon; Kozina, Michael; Jiang, Mason; Henighan, Thomas; Bray, Crystal; Ndabashimiye, Georges; Bucksbaum, P H; Feng, Yiping; Herrmann, Sven; Carini, Gabriella; Pines, Jack; Hart, Philip; Kenney, Christopher; Guillet, Serge; Boutet, Sebastien; Williams, Garth; Messerschmidt, Marc; Seibert, Marvin; Moeller, Stefan; Hastings, Jerome B; Reis, David A

    2015-01-01

    X-ray scattering is a weak linear probe of matter. It is primarily sensitive to the position of electrons and their momentum distribution. Elastic X-ray scattering forms the basis of atomic structural determination while inelastic Compton scattering is often used as a spectroscopic probe of both single-particle excitations and collective modes. X-ray free-electron lasers (XFELs) are unique tools for studying matter on its natural time and length scales due to their bright and coherent ultrashort pulses. However, in the focus of an XFEL the assumption of a weak linear probe breaks down, and nonlinear light-matter interactions can become ubiquitous. The field can be sufficiently high that even non-resonant multiphoton interactions at hard X-rays wavelengths become relevant. Here we report the observation of one of the most fundamental nonlinear X-ray-matter interactions, the simultaneous Compton scattering of two identical photons producing a single photon at nearly twice the photon energy. We measure scattered...

  16. X-ray echo spectroscopy (Conference Presentation)

    Science.gov (United States)

    Shvyd'ko, Yuri V.

    2016-09-01

    X-ray echo spectroscopy, a counterpart of neutron spin-echo, was recently introduced [1] to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x-rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-meV and 0.02-meV ultra-high-resolution IXS applications (resolving power > 10^8) with broadband 5-13 meV dispersing systems will be presented featuring more than 1000-fold signal enhancement. The technique is general, applicable in different photon frequency domains. [1.] Yu. Shvyd'ko, Phys. Rev. Lett. 116, accepted (2016), arXiv:1511.01526.

  17. X-ray emission processes in stars

    CERN Document Server

    Testa, Paola

    2010-01-01

    A decade of X-ray stellar observations with Chandra and XMM-Newton has led to significant advances in our understanding of the physical processes at work in hot (magnetized) plasmas in stars and their immediate environment, providing new perspectives and challenges, and in turn the need for improved models. The wealth of high-quality stellar spectra has allowed us to investigate, in detail, the characteristics of the X-ray emission across the HR diagram. Progress has been made in addressing issues ranging from classical stellar activity in stars with solar-like dynamos (such as flares, activity cycles, spatial and thermal structuring of the X-ray emitting plasma, evolution of X-ray activity with age), to X-ray generating processes (e.g. accretion, jets, magnetically confined winds) that were poorly understood in the pre-Chandra/XMM-Newton era. I discuss the progress made in the study of high energy stellar physics and its impact in a wider astrophysical context, focusing on the role of spectral diagnostics no...

  18. X-ray optics of gold nanoparticles.

    Science.gov (United States)

    Letfullin, Renat R; Rice, Colin E W; George, Thomas F

    2014-11-01

    Gold nanoparticles have been investigated as contrast agents for traditional x-ray medical procedures, utilizing the strong absorption characteristics of the nanoparticles to enhance the contrast of the detected x-ray image. Here we use the Kramers-Kronig relation for complex atomic scattering factors to find the real and imaginary parts of the index of refraction for the medium composed of single-element materials or compounds in the x-ray range of the spectrum. These complex index of refraction values are then plugged into a Lorenz-Mie theory to calculate the absorption efficiency of various size gold nanoparticles for photon energies in the 1-100 keV range. Since the output from most medical diagnostic x-ray devices follows a wide and filtered spectrum of photon energies, we introduce and compute the effective intensity-absorption-efficiency values for gold nanoparticles of radii varying from 5 to 50 nm, where we use the TASMIP model to integrate over all spectral energies generated by typical tungsten anode x-ray tubes with kilovolt potentials ranging from 50 to 150 kVp.

  19. X-ray absorption spectroscopy of metalloproteins.

    Science.gov (United States)

    Ward, Jesse; Ollmann, Emily; Maxey, Evan; Finney, Lydia A

    2014-01-01

    Metalloproteins are enormously important in biology. While a variety of techniques exist for studying metals in biology, X-ray absorption spectroscopy is particularly useful in that it can determine the local electronic and physical structure around the metal center, and is one of the few avenues for studying "spectroscopically silent" metal ions like Zn(II) and Cu(I) that have completely filled valence bands. While X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) are useful for studying metalloprotein structure, they suffer the limitation that the detected signal is an average of all the various metal centers in the sample, which limits its usefulness for studying metal centers in situ or in cell lysates. It would be desirable to be able to separate the various proteins in a mixture prior to performing X-ray absorption studies, so that the derived signal is from one species only. Here we describe a method for performing X-ray absorption spectroscopy on protein bands following electrophoretic separation and western blotting.

  20. Optics for coherent X-ray applications.

    Science.gov (United States)

    Yabashi, Makina; Tono, Kensuke; Mimura, Hidekazu; Matsuyama, Satoshi; Yamauchi, Kazuto; Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji; Ohashi, Haruhiko; Goto, Shunji; Ishikawa, Tetsuya

    2014-09-01

    Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed.

  1. Thin Shell, Segmented X-Ray Mirrors

    Science.gov (United States)

    Petre, Robert

    2010-01-01

    Thin foil mirrors were introduced as a means of achieving high throughput in an X-ray astronomical imaging system in applications for which high angular resolution were not necessary. Since their introduction, their high filling factor, modest mass, relative ease of construction, and modest cost have led to their use in numerous X-ray observatories, including the Broad Band X-ray Telescope, ASCA, and Suzaku. The introduction of key innovations, including epoxy replicated surfaces, multilayer coatings, and glass mirror substrates, has led to performance improvements, and in their becoming widely used for X-ray astronomical imaging at energies above 10 keV. The use of glass substrates has also led to substantial improvement in angular resolution, and thus their incorporation into the NASA concept for the International X-ray Observatory with a planned 3 in diameter aperture. This paper traces the development of foil mirrors from their inception in the 1970's through their current and anticipated future applications.

  2. Supergiant Fast X-ray Transients

    CERN Document Server

    Sidoli, Lara

    2011-01-01

    The phenomenology of a subclass of High Mass X-ray Binaries hosting a blue supergiant companion, the so-called Supergiant Fast X-ray Transients (SFXTs), is reviewed. Their number is growing, mainly thanks to the discoveries performed by the INTEGRAL satellite, then followed by soft X-rays observations (both aimed at refining the source position and at monitoring the source behavior) leading to the optical identification of the blue supergiant nature of the donor star. Their defining properties are a transient X-ray activity consisting of sporadic, fast and bright flares, (each with a variable duration between a few minutes and a few hours), reaching 1E36-1E37 erg/s. The quiescence is at a luminosity of 1E32 erg/s, while their more frequent state consists of an intermediate X-ray emission of 1E33-1E34 erg/s (1-10 keV). Only the brightest flares are detected by INTEGRAL (>17 keV) during short pointings, with no detected persistent emission. The physical mechanism driving the short outbursts is still debated, al...

  3. Effect of X-Rays on the Mechanical Properties of Aluminized FEP Teflon(R)

    Science.gov (United States)

    Gaier, James R.; Brinkmeier, Michael R.; Gaier, Elizabeth M.

    1998-01-01

    Pieces of the multilayer insulation (MLI) that is integral to the thermal control of the Hubble Space Telescope (HST) have been returned by two servicing missions after 3.6 and 6.8 years in orbit. They reveal that the outer layer, which is made from 5 mil (0.13 mm)thick aluminized fluorinated ethylene propylene(FEP) Teflon(R), has become severely embrittled. Although possible agents of this embrittlement include electromagnetic radiation across the entire solar spectrum, trapped particle radiation, atomic oxygen, and thermal cycling, intensive investigations have not yielded unambiguous causes. Previous studies utilizing monoenergetic photons in the 69-1900 eV range did not cause significant embrittlement, even at much higher doses than were experienced by the HST MLI. Neither did x-rays in the 3 to 10 keV range generated in a modified electron beam evaporator. An antidotal aluminized FEP sample that was exposed to an intensive dose from unfiltered Mo x-ray radiation from a rotating anode generator, however, did show the requisite embrittlement. Thus, a study was undertaken to determine the effects of x-ray exposure on the embrittlement of aluminized FEP in hopes that it might elucidate the HST MLI degradation mechanism. Tensile specimens of aluminized 5 mil thick FEP were exposed to a constant fluence of unfiltered x-ray radiation from a Mo target whose maximum energy ranged from 20-60 kV. Other samples were annealed, thermally cycled (100x) between 77-333 K, or cycled and irradiated. Tensile tests and density measurements were then performed on the samples. Only the samples which had been irradiated had the drastically reduced elongation-to-break, characteristic of the HST samples. Thermal cycling may accelerate the embrittlement, but the effect was near the scatter in the measurements. Annealing and thermal cycling had no apparent effect. Only the samples which had been irradiated and annealed showed significant density increases, likely implicating polymer

  4. Structure of biomembrane-on-silicon hybrids derived from X-ray reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Birkholz, M. [IHP, Im Technologiepark 25, D-15236 Frankfurt (Germany)]. E-mail: birkholz@ihp-microelectronics.com; Zaumseil, P. [IHP, Im Technologiepark 25, D-15236 Frankfurt (Germany); Kittler, M. [IHP, Im Technologiepark 25, D-15236 Frankfurt (Germany); Wallat, I. [Fachbereich Physik, FU Berlin, Arnimallee 14, D-14195 Berlin (Germany); Heyn, M.P. [Fachbereich Physik, FU Berlin, Arnimallee 14, D-14195 Berlin (Germany)

    2006-10-15

    The organic-inorganic interface and its proper structural adjustment are of central importance for the fabrication of hybrid material systems from biomolecules and semiconductors. Such material hybrids are currently under development for several advanced applications, in particular for biomolecular sensing. An investigation of biomolecular immobilization on semiconductor surfaces by X-ray reflectometry (XRR) will be presented. Complete biomembrane patches of purple membrane (PM) from Halobacterium salinarum were immobilized on oxidized and nitrided silicon wafers. A covalent immobilization protocol based on 3-aminopropyltriethoxysilane (APTS) and glutaric dialdehyde (GD) was applied for cross-linking the biomolecules to the semiconductor surface. XRR could be shown to yield the relevant morphological parameters of biomolecular monolayers such as layer thickness, interface roughness and coverage. Synchrotron radiation was not required, but a laboratory rotating anode set-up was sufficient to study the prepared stacking of organic monolayers. According to the measurement and analysis of XRR patterns both cross-linking layers APTS and GD are required for bonding purple membrane patches to SiO{sub 2}/Si, whereas GD alone suffices for cross-linking to Si{sub 3}N{sub 4}/Si. This distinct behavior offers a pathway for nanopatterning of biomolecules on Si surfaces by selective passivation.

  5. Crystallization and preliminary X-ray diffraction analysis of restriction endonuclease EcoRII

    Science.gov (United States)

    Karpova, E. A.; Meehan, E.; Pusey, M. L.; Chen, L.

    1999-01-01

    Crystals of the restriction endonuclease EcoRII have been obtained by the vapor-diffusion technique in the presence of ammonium sulfate or polyethylene glycol. The best crystals were grown with ammonium sulfate as a precipitant. Crystals with dimensions of up to 0.6 x 0. 6 x 0.6 mm have been observed. The crystals diffract to about 4.0 A resolution at a cryo-temperature of 100 K using a rotating-anode X-ray source and a Rigaku R-AXIS IV imaging-plate detector. The space group has been determined to be either I23 or I2(1)3, with unit-cell parameters a = b = c = 160.3 A, alpha = beta = gamma = 90 degrees. The crystal asymmetric unit contains two protein molecules, and self-rotation function analysis shows a pseudo-twofold symmetry relating the two monomers. Attempts to improve the resolution of crystal diffraction and to search for heavy-atom derivatives are under way.

  6. Review of X-ray Tomography and X-ray Fluorescence Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shear, Trevor A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    This literature review will focus on both laboratory and synchrotron based X-ray tomography of materials and highlight the inner workings of these instruments. X-ray fluorescence spectroscopy will also be reviewed and applications of the tandem use of these techniques will be explored. The real world application of these techniques during the internship will also be discussed.

  7. Femtosecond X-ray Absorption Spectroscopy at a Hard X-ray Free Electron Laser

    DEFF Research Database (Denmark)

    Lemke, Henrik T.; Bressler, Christian; Chen, Lin X.

    2013-01-01

    X-ray free electron lasers (XFELs) deliver short (<100 fs) and intense (similar to 10(12) photons) pulses of hard X-rays, making them excellent sources for time-resolved studies. Here we show that, despite the inherent instabilities of current (SASE based) XFELs, they can be used for measuring hi...

  8. X-ray reflection in oxygen-rich accretion discs of ultracompact X-ray binaries

    DEFF Research Database (Denmark)

    Madej, O. K.; Garcia, Jeronimo; Jonker, P. G.

    2014-01-01

    We present spectroscopic X-ray data of two candidate ultracompact X-ray binaries (UCXBs): 4U 0614+091 and 4U 1543-624. We confirm the presence of a broad O viii Ly alpha reflection line (at a parts per thousand 18 angstrom) using XMM-Newton and Chandra observations obtained in 2012 and 2013. The ...

  9. X-ray Polarization from High Mass X-ray Binaries

    CERN Document Server

    Kallman, T; Blondin, J

    2015-01-01

    X-ray astronomy allows study of objects which may be associated with compact objects, i.e. neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically non-spherical, and likely non-circular when projected on the sky. Polarization allows study of such geoemetric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. A class of potential targets for future X-ray polarization observations is the high mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early type star. In this paper ws show that X-ray polarization from HMXBs has a distinct signature which depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclips...

  10. X-ray Spectral Variation of Eta Carinae through the 2003 X-ray Minimum

    CERN Document Server

    Hamaguchi, K; Gull, T; Ishibashi, K; Pittard, J M; Hillier, D J; Damineli, A; Davidson, K; Nielsen, K E; Kober, G V; Hamaguchi, Kenji; Corcoran, Michael F.; Gull, Theodore; Ishibashi, Kazunori; Pittard, Julian M.; Damineli, Augusto; Davidson, Kris; Nielsen, Krister E.; Kober, Gladys Vieira

    2007-01-01

    We report the results of an X-ray observing campaign on the massive, evolved star Eta Carinae, concentrating on the 2003 X-ray minimum as seen by the XMM-Newton observatory. These are the first spatially-resolved X-ray monitoring observations of the stellar X-ray spectrum during the minimum. The hard X-ray emission, believed to be associated with the collision of Eta Carinae's wind with the wind from a massive companion star, varied strongly in flux on timescales of days, but not significantly on timescales of hours. The lowest X-ray flux in the 2-10 keV band seen by XMM-Newton was only 0.7% of the maximum seen by RXTE just before the X-ray minimum. The slope of the X-ray continuum above 5 keV did not vary in any observation, which suggests that the electron temperature of the hottest plasma associated with the stellar source did not vary significantly at any phase. Through the minimum, the absorption to the stellar source increased by a factor of 5-10 to NH ~3-4E23 cm-2. The thermal Fe XXV emission line show...

  11. Hard X-ray emission from neutron star X-ray binaries

    Energy Technology Data Exchange (ETDEWEB)

    Di Salvo, T.; Santangelo, A.; Segreto, A

    2004-06-01

    In this paper we review our current knowledge of the hard X-ray emission properties of accreting X-ray Binary Pulsars and old accreting neutron stars in Low Mass X-ray Binaries in light of 7 years of BeppoSAX and RXTE observations. The paper is divided in two parts. In the first part we review the more recent findings on the phase-dependent broad band continua and cyclotron resonance scattering features observed in many systems of the X-ray Binary Pulsar class. In the second part we review the hard X-ray emission of LMXRB focussing on the hard X-ray components extending up to energies of a few hundred keV that have been clearly detected in sources of both the atoll and Z classes. The presence and characteristics of these hard emission components are then discussed in relation to source properties and spectral state. We, also, briefly mention models that have been proposed for the hard X-ray emission of neutron star X-ray binaries.

  12. X-ray Polarization in Relativistic Jets

    CERN Document Server

    McNamara, Aimee L; Wu, Kinwah

    2009-01-01

    We investigate the polarization properties of Comptonized X-rays from relativistic jets in Active Galactic Nuclei (AGN) using Monte Carlo simulations. We consider three scenarios commonly proposed for the observed X-ray emission in AGN: Compton scattering of blackbody photons emitted from an accretion disk; scattering of cosmic microwave background (CMB) photons; and self-Comptonization of intrinsically polarized synchrotron photons emitted by jet electrons. Our simulations show that for Comptonization of disk and CMB photons, the degree of polarization of the scattered photons increases with the viewing inclination angle with respect to the jet axis. In both cases the maximum linear polarization is approximately 20%. In the case of synchrotron self-Comptonization (SSC), we find that the resulting X-ray polarization depends strongly on the seed synchrotron photon injection site, with typical fractional polarizations of approximately P = 10 - 20% when synchrotron emission is localized near the jet base, while ...

  13. X-Ray Wakes in Abell 160

    CERN Document Server

    Drake, N; Sakelliou, I; Pinkney, J C; Drake, Nick; Merrifield, Michael R.; Sakelliou, Irini; Pinkney, Jason C.

    2000-01-01

    `Wakes' of X-ray emission have now been detected trailing behind a few (at least seven) elliptical galaxies in clusters. To quantify how widespread this phenomenon is, and what its nature might be, we have obtained a deep (70 ksec) X-ray image of the poor cluster Abell 160 using the ROSAT HRI. Combining the X-ray data with optical positions of confirmed cluster members, and applying a statistic designed to search for wake-like excesses, we confirm that this phenomenon is observed in galaxies in this cluster. The probability that the detections arise from chance is less than 0.0038. Further, the wakes are not randomly distributed in direction, but are preferentially oriented pointing away from the cluster centre. This arrangement can be explained by a simple model in which wakes arise from the stripping of their host galaxies' interstellar media due to ram pressure against the intracluster medium through which they travel.

  14. The quantum X-ray radiology apparatus

    CERN Document Server

    Hilt, B; Prevot, G

    2000-01-01

    The paper entitled 'New Quantum Detection System for Very Low Dose X-ray Radiology', presented at the talk session, discusses the preliminary data obtained using a new quantum X-ray radiology system with a high-efficiency solid-state detector and highly sensitive electronics, making it possible to reduce significantly the dose administered to a patient in X-ray radiology examinations. The present paper focuses more on the technological aspects of the apparatus, such as the integration of the detector with the two Asics, and the computer system. Namely, it is shown how the computer system calibrates the detection system, acquires the data in real time, and controls the scan parameters and image filtering process.

  15. X-ray optics developments at ESA

    DEFF Research Database (Denmark)

    Bavdaz, M.; Wille, E.; Wallace, K.;

    2013-01-01

    ) in collaboration with research institutions and industry, enabling leading-edge future science missions. Silicon Pore Optics (SPO) [1 to 21] and Slumped Glass Optics (SGO) [22 to 29] are lightweight high performance X-ray optics technologies being developed in Europe, driven by applications in observatory class......Future high energy astrophysics missions will require high performance novel X-ray optics to explore the Universe beyond the limits of the currently operating Chandra and Newton observatories. Innovative optics technologies are therefore being developed and matured by the European Space Agency (ESA...... reflective coatings [30 to 35]. In addition, the progress with the X-ray test facilities and associated beam-lines is discussed [36]. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  16. Contact x-ray microscopy using Asterix

    Science.gov (United States)

    Conti, Aldo; Batani, Dimitri; Botto, Cesare; Masini, Alessandra; Bernardinello, A.; Bortolotto, Fulvia; Moret, M.; Poletti, G.; Piccoli, S.; Cotelli, F.; Lora Lamia Donin, C.; Stead, Anthony D.; Marranca, A.; Eidmann, Klaus; Flora, Francesco; Palladino, Libero; Reale, Lucia

    1997-10-01

    The use of a high energy laser source for soft x-ray contact microscopy is discussed. Several different targets were used and their emission spectra compared. The x-ray emission, inside and outside the Water Window, was characterized in detail by means of many diagnostics, including pin hole and streak cameras. Up to 12 samples holders per shot were exposed thanks to the large x-ray flux and the geometry of the interaction chamber. Images of several biological samples were obtained, including Chlamydomonas and Crethidia green algae, fish and boar sperms and Saccharomyces Cerevisiae yeast cells. A 50 nm resolution was reached on the images of boar sperm. Original information concerning the density of inner structures of Crethidia green algae were obtained.

  17. Laboratory Data for X-Ray Astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.; Brown, G.V.; Chen, H.; Gu, M.F.; Kahn, S.M.; Lepson, J.K.; Savin, D.W.; Utter, S.B.

    2000-03-02

    Laboratory facilities have made great strides in producing large sets of reliable data for X-ray astronomy, which include ionization and recombination cross sections needed for charge balance calculations as well as the atomic data needed for interpreting X-ray line formation. We discuss data from the new generation sources and pay special attention to the LLNL electron beam ion trap experiment, which is unique in it's ability to provide direct laboratory access to spectral data under precisely controlled conditions that simulate those found in many astrophysical plasmas. Examples of spectral data obtained in the 1-160 A wavelength range are given illustrating the type of laboratory X-ray data produced in support of such missions as Chandra, XMM, ASCA and EUVE.

  18. Filtered fluorescer x-ray detector

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, H.C.; Emig, J.A.; Thoe, R.S.; Springer, P.T.; Hernandez, J.A.

    1995-04-01

    Recently, an instrument capable of measuring x-rays between 8 and 90 keV was conceived to help understand conditions pertaining to pulsed power research. This resulted in the development of a versatile device that would incrementally detect x-rays emitted at predetermined energy bands over this range. To accomplish this, an array of well characterized filter-fluorescer combinations were produced which would allow fluoresced x-rays to be observed by time resolved electro-optical devices. As many as sixteen channels could be utilized with each channel having a corresponding background channel. Upon completion of the device, a three week series of experiments was then successfully carried out.

  19. X-Ray Detector Simulations - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Tina, Adrienne [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-20

    The free-electron laser at LCLS produces X-Rays that are used in several facilities. This light source is so bright and quick that we are capable of producing movies of objects like proteins. But making these movies would not be possible without a device that can detect the X-Rays and produce images. We need X-Ray cameras. The challenges LCLS faces include the X-Rays’ high repetition rate of 120 Hz, short pulses that can reach 200 femto-seconds, and extreme peak brightness. We need detectors that are compatible with this light source, but before they can be used in the facilities, they must first be characterized. My project was to do just that, by making a computer simulation program. My presentation discusses the individual detectors I simulated, the details of my program, and how my project will help determine which detector is most useful for a specific experiment.

  20. Bone diagnosis by X-ray techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lima, I. [Nuclear Engineering Program/COPPE/UFRJ, P.O. Box 68509, Av. Horacio Macedo, 2030, Sala I-133, Cidade Universitaria, Zip Code: 21941-972 Rio de Janeiro, RJ (Brazil)], E-mail: inaya@lin.ufrj.br; Anjos, M.J. [Nuclear Engineering Program/COPPE/UFRJ, P.O. Box 68509, Av. Horacio Macedo, 2030, Sala I-133, Cidade Universitaria, Zip Code: 21941-972 Rio de Janeiro, RJ (Brazil); Physics Institute, UERJ (Brazil); Farias, M.L.F. [University Hospital, UFRJ (Brazil); Parcegoni, N.; Rosenthal, D. [Biophysics Institute, UFRJ (Brazil); Duarte, M.E.L. [Histologic and Embriology Department, UFRJ (Brazil); Lopes, R.T. [Nuclear Engineering Program/COPPE/UFRJ, P.O. Box 68509, Av. Horacio Macedo, 2030, Sala I-133, Cidade Universitaria, Zip Code: 21941-972 Rio de Janeiro, RJ (Brazil)

    2008-12-15

    In this work, two X-ray techniques used were 3D microcomputed tomography (micro-CT) and X-ray microfluorescence (micro-XRF) in order to investigate the internal structure of the bone samples. Those two techniques work together, e.g. as a complement to each other, to characterize bones structure and composition. Initially, the specimens were used to do the scan procedure in the microcomputer tomography system and the second step consists of doing the X-ray microfluorescence analysis. The results show that both techniques are powerful methods for analyzing, inspecting and characterizing bone samples: they are alternative procedures for examining bone structures and compositions and they are complementary.

  1. Microfabrication of hard x-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik

    heights and improved uniformity compared to what is currently available. To this end, established fabrication procedures are improved and the toolbox used for lens development is enriched. The central theme of this thesis is x-ray microscopy (XRM). As a spearhead of today’s materials research it provides...... in turn asks for highly precise metrology. Therefore, a mix of techniques including optical profilometry and atomic force microscopy (AFM) has been used to obtain reliable information about the detailed three-dimensional shapes of the lenses. Adequate sample preparation and measuring procedures have been...... of space for sample surroundings and ensure low-divergent and wide x-ray beams with narrow waists. Both results are substantial improvements to what was available at the start of this thesis work. The challenge of making x-ray objectives in silicon by interdigitation of lenslets alternately focusing...

  2. Supernova remnants: the X-ray perspective

    Science.gov (United States)

    Vink, Jacco

    2012-12-01

    Supernova remnants are beautiful astronomical objects that are also of high scientific interest, because they provide insights into supernova explosion mechanisms, and because they are the likely sources of Galactic cosmic rays. X-ray observations are an important means to study these objects. And in particular the advances made in X-ray imaging spectroscopy over the last two decades has greatly increased our knowledge about supernova remnants. It has made it possible to map the products of fresh nucleosynthesis, and resulted in the identification of regions near shock fronts that emit X-ray synchrotron radiation. Since X-ray synchrotron radiation requires 10-100 TeV electrons, which lose their energies rapidly, the study of X-ray synchrotron radiation has revealed those regions where active and rapid particle acceleration is taking place. In this text all the relevant aspects of X-ray emission from supernova remnants are reviewed and put into the context of supernova explosion properties and the physics and evolution of supernova remnants. The first half of this review has a more tutorial style and discusses the basics of supernova remnant physics and X-ray spectroscopy of the hot plasmas they contain. This includes hydrodynamics, shock heating, thermal conduction, radiation processes, non-equilibrium ionization, He-like ion triplet lines, and cosmic ray acceleration. The second half offers a review of the advances made in field of X-ray spectroscopy of supernova remnants during the last 15 year. This period coincides with the availability of X-ray imaging spectrometers. In addition, I discuss the results of high resolution X-ray spectroscopy with the Chandra and XMM-Newton gratings. Although these instruments are not ideal for studying extended sources, they nevertheless provided interesting results for a limited number of remnants. These results provide a glimpse of what may be achieved with future microcalorimeters that will be available on board future X-ray

  3. Electromagnetically induced transparency for x rays

    CERN Document Server

    Buth, Christian; Young, Linda

    2007-01-01

    Electromagnetically induced transparency (EIT) is predicted for x rays in laser-dressed neon gas. The x-ray photoabsorption cross section and polarizability near the Ne K edge are calculated using an ab initio theory suitable for optical strong-field problems. The laser wavelength is tuned close to the transition between 1s^-1 3s and 1s^-1 3p (approximately 800nm). The minimum laser intensity required to observe EIT is of the order of 10^12 W/cm^2. The ab initio results are discussed in terms of an exactly solvable three-level model. This work opens new opportunities for research with ultrafast x-ray sources.

  4. The X-ray imager on AXO

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan; Westergaard, Niels Jørgen Stenfeldt

    2001-01-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated....... Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X...... thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20 x 40cm(2) CZT detector array covering an energy range from 5 to 200keV....

  5. Uncertainty calculations for the measurement of in vivo bone lead by x-ray fluorescence.

    Science.gov (United States)

    O'Meara, J M; Fleming, D E B

    2009-04-21

    In order to quantify the bone lead concentration from an in vivo x-ray fluorescence measurement, typically two estimates of the lead concentration are determined by comparing the normalized x-ray peak amplitudes from the Kalpha(1) and Kbeta(1) features to those of the calibration phantoms. In each case, the normalization consists of taking the ratio of the x-ray peak amplitude to the amplitude of the coherently scattered photon peak in the spectrum. These two Pb concentration estimates are then used to determine the weighted mean lead concentration of that sample. In calculating the uncertainties of these measurements, it is important to include any covariance terms where appropriate. When determining the uncertainty of the lead concentrations from each x-ray peak, the standard approach does not include covariance between the x-ray peaks and the coherently scattered feature. These spectral features originate from two distinct physical processes, and therefore no covariance between these features can exist. Through experimental and simulated data, we confirm that there is no observed covariance between the detected Pb x-ray peaks and the coherently scattered photon signal, as expected. This is in direct contrast to recent work published by Brito (2006 Phys. Med. Biol. 51 6125-39). There is, however, covariance introduced in the calculation of the weighted mean lead concentration due to the common coherent normalization. This must be accounted for in calculating the uncertainty of the weighted mean lead concentration, as is currently the case. We propose here an alternative approach to calculating the weighted mean lead concentration in such a way as to eliminate the covariance introduced by the common coherent normalization. It should be emphasized that this alternative approach will only apply in situations in which the calibration line intercept is not included in the calculation of the Pb concentration from the spectral data: when the source of the intercept is

  6. Novel X-ray telescopes for wide-field X-ray monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudec, R. [Academy of science of Czech Republic, Ondrejov (Czech Republic); Inneman, A. [Centre for advanced X-ray technologies Reflex sro, Prague (Czech Republic); Pina, L.; Sveda, L. [Czech Technical Univ., Prague (Czech Republic). Faculty of Nuclear Science

    2005-07-15

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science.

  7. Single Particle X-ray Diffractive Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bogan, M J; Benner, W H; Boutet, S; Rohner, U; Frank, M; Seibert, M; Maia, F; Barty, A; Bajt, S; Riot, V; Woods, B; Marchesini, S; Hau-Riege, S P; Svenda, M; Marklund, E; Spiller, E; Hajdu, J; Chapman, H N

    2007-10-01

    In nanotechnology, strategies for the creation and manipulation of nanoparticles in the gas phase are critically important for surface modification and substrate-free characterization. Recent coherent diffractive imaging with intense femtosecond X-ray pulses has verified the capability of single-shot imaging of nanoscale objects at sub-optical resolutions beyond the radiation-induced damage threshold. By intercepting electrospray-generated particles with a single 15 femtosecond soft-X-ray pulse, we demonstrate diffractive imaging of a nanoscale specimen in free flight for the first time, an important step toward imaging uncrystallized biomolecules.

  8. Cosmic X-ray background and solitars.

    Science.gov (United States)

    Chiu, H.-Y.

    In this paper the authors has examined the observational consequences of a class of new astronomical objects proposed by Friedberg, Lee and Pang, called solitars which are degenerate vacuum states embedded with particles. A study is made to include finite temperature effect and pair creation. Quark is believed to be the only species that can exist in the interior of solitars. Massive quark solitars are primarily X-ray emitters and may account for the large unexplained thermal component of the cosmic X-ray background.

  9. Tokamak Spectroscopy for X-Ray Astronomy

    Science.gov (United States)

    Fournier, Kevin B.; Finkenthal, M.; Pacella, D.; May, M. J.; Soukhanovskii, V.; Mattioli, M.; Leigheb, M.; Rice, J. E.

    2000-01-01

    This paper presents the measured x-ray and Extreme Ultraviolet (XUV) spectra of three astrophysically abundant elements (Fe, Ca and Ne) from three different tokamak plasmas. In every case, each spectrum touches on an issue of atomic physics that is important for simulation codes to be used in the analysis of high spectral resolution data from current and future x-ray telescopes. The utility of the tokamak as a laboratory test bed for astrophysical data is demonstrated. Simple models generated with the HULLAC suite of codes demonstrate how the atomic physics issues studied can affect the interpretation of astrophysical data.

  10. European XFEL: Soft X-Ray instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Molodtsov, S. L., E-mail: serguei.molodtsov@xfel.eu [European XFEL GmbH (Germany)

    2011-12-15

    The currently constructed European X-Ray Free Electron Laser (XFEL) will generate new knowledge in almost all the technical and scientific disciplines that are shaping our daily life-including nanotechnology, medicine, pharmaceutics, chemistry, materials science, power engineering and electronics. On 8 January 2009, civil engineering work (tunnels, shafts, halls) has been started at all three construction sites. In this presentation status and parameters of the European XFEL facility and instrumentation as well as planned research applications particularly in the range of soft X-rays are reviewed.

  11. Imaging plates calibration to X-rays

    Science.gov (United States)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  12. Radiobiological studies using gamma and x rays.

    Energy Technology Data Exchange (ETDEWEB)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R.; Lin, Yong; Wilder, Julie; Hutt, Julie A.; Padilla, Mabel T.; Gott, Katherine M.

    2013-02-01

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  13. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Susan Zappala

    Full Text Available X-ray Computed Tomography (CT is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy. However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored.

  14. 20 CFR 718.102 - Chest roentgenograms (X-rays).

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification...-rays as described in Appendix A. (b) A chest X-ray to establish the existence of pneumoconiosis...

  15. Differential phase contrast X-ray imaging system and components

    Science.gov (United States)

    Stutman, Daniel; Finkenthal, Michael

    2014-07-01

    A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

  16. Differential phase contrast X-ray imaging system and components

    Energy Technology Data Exchange (ETDEWEB)

    Stutman, Daniel; Finkenthal, Michael

    2017-01-31

    A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

  17. Constraining possible variations of the fine structure constant in strong gravitational fields with the K$\\alpha$ iron line

    CERN Document Server

    Bambi, Cosimo

    2013-01-01

    Extensions of general relativity and theories aiming at unifying gravity with the forces of the Standard Model are usually characterized by new degrees of freedom and violations of the Einstein Equivalence Principle. The search for time and/or space variations of fundamental parameters like the fine structure constant $\\alpha$ tests the assumption of Local Position Invariance. In this letter, I show that the analysis of the K$\\alpha$ iron line observed in the X-ray spectrum of black holes can probe $\\alpha$ in gravitational potentials relative to Earth of $\\Delta \\phi \\approx 0.1$. From the measurements of the black hole in Cygnus X-1 reported in the literature, one obtains $|\\Delta \\alpha / \\alpha| \\lesssim 0.01$.

  18. Resolving the Composite Fe K-alpha Emission Line in the Galactic Black Hole Cygnus X-1 with Chandra

    CERN Document Server

    Miller, J M; Wijnands, R; Remillard, R A; Wojdowski, P S; Schulz, N S; Matteo, T D; Marshall, H L; Canizares, C R; Pooley, D; Lewin, W H G

    2002-01-01

    We observed the Galactic black hole Cygnus X-1 with the Chandra High Energy Transmission Grating Spectrometer for 30 kiloseconds on 4 January, 2001. The source was in an intermediate state, with a flux that was approximately twice that commonly observed in its persistent low/hard state. Our best-fit model for the X-ray spectrum includes narrow Gaussian emission line (E = 6.415 +/- 0.007 keV, FWHM = 80 (+28, -19) eV, W = 16 (+3, -2) eV) and broad line (E = 5.82 (+0.06, -0.07) keV, FWHM = 1.9 (+0.5, -0.3) keV, W = 140 (+70, -40) eV) components, and a smeared edge at 7.3 +/- 0.2 keV (tau ~ 1.0). The broad line profile is not as strongly skewed as those observed in some Seyfert galaxies. We interpret these features in terms of an accretion disk with irradiation of the inner disk producing a broad Fe K-alpha emission line and edge, and irradiation of the outer disk producing a narrow Fe K-alpha emission line. The broad line is likely shaped predominantly by Doppler shifts and gravitational effects, and to a lesser...

  19. Superoxide reductase from the syphilis spirochete Treponema pallidum: crystallization and structure determination using soft X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Silva, Teresa; Trincão, José; Carvalho, Ana L.; Bonifácio, Cecília; Auchère, Françoise; Moura, Isabel; Moura, José J. G.; Romão, Maria J., E-mail: mromao@dq.fct.unl.pt [REQUIMTE Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal)

    2005-11-01

    Superoxide reductase is a non-haem iron-containing protein involved in resistance to oxidative stress. The oxidized form of the protein has been crystallized and its three-dimensional structure solved. A highly redundant X-ray diffraction data set was collected on a rotating-anode generator using Cu Kα X-ray radiation. Four Fe atoms were located in the asymmetric unit corresponding to four protein molecules arranged as a dimer of homodimers. Superoxide reductase is a 14 kDa metalloprotein containing a catalytic non-haem iron centre [Fe(His){sub 4}Cys]. It is involved in defence mechanisms against oxygen toxicity, scavenging superoxide radicals from the cell. The oxidized form of Treponema pallidum superoxide reductase was crystallized in the presence of polyethylene glycol and magnesium chloride. Two crystal forms were obtained depending on the oxidizing agents used after purification: crystals grown in the presence of K{sub 3}Fe(CN){sub 6} belonged to space group P2{sub 1} (unit-cell parameters a = 60.3, b = 59.9, c = 64.8 Å, β = 106.9°) and diffracted beyond 1.60 Å resolution, while crystals grown in the presence of Na{sub 2}IrCl{sub 6} belonged to space group C2 (a = 119.4, b = 60.1, c = 65.6 Å, β = 104.9°) and diffracted beyond 1.55 Å. A highly redundant X-ray diffraction data set from the C2 crystal form collected on a copper rotating-anode generator (λ = 1.542 Å) clearly defined the positions of the four Fe atoms present in the asymmetric unit by SAD methods. A MAD experiment at the iron absorption edge confirmed the positions of the previously determined iron sites and provided better phases for model building and refinement. Molecular replacement using the P2{sub 1} data set was successful using a preliminary trace as a search model. A similar arrangement of the four protein molecules could be observed.

  20. Purification, crystallization and preliminary X-ray diffraction studies of C-phycocyanin and allophycocyanin from Spirulina platensis.

    Science.gov (United States)

    Moreno, A; Bermejo, R; Talavera, E; Alvarez-Pez, J M; Sanz-Aparicio, J; Romero-Garrido, A

    1997-05-01

    C-phycocyanin and allophycocyanin from the green alga Spirulina platensis were isolated and crystallized by gel-acupuncture techniques. A novel two-step chromatographic procedure was used for purification. Blue hexagonal crystals were obtained by diffusing magnesium chloride into the protein solution for a week, followed by diffusion of PEG 6000 in order to complete the reduction of the solubility of the protein in the capillary tube used as a growth cell. In the case of allophycocyanin, crystals with a size of 0.4 x 0.3 x 0.3 mm were characterized by X-ray diffraction. They belong to space group P6(3)22 with unit-cell parameters a = b = 102.04, c = 131.22 A. The crystals of C-phycocyanin belong to either space group P6 or P6(3) with unit-cell constants a = b = 182.38, c = 60.87 A, alpha = beta = 90, gamma = 120 degrees. The crystals diffract beyond 2.4 and 2.5 A resolution, respectively, using a rotating anode as an X-ray source.

  1. Delving into X-Ray Obscuration of Type 2 AGN, Near and Far

    Science.gov (United States)

    Lamassa, Stephanie M.; Yaqoob, Tahir; Ptak, Andrew F.; Jia, Jianjun; Heckman, Timothy M.; Gandhi, Poshak; Urry, C. Meg

    2014-01-01

    Using self-consistent, physically motivated models, we investigate the X-ray obscuration in 19 Type 2 [O iii] 5007Å selected active galactic nuclei (AGNs), 9 of which are local Seyfert 2 galaxies and 10 of which are Type 2 quasar candidates. We derive reliable line-of-sight and global column densities for these objects, which is the first time this has been reported for an AGN sample; four AGNs have significantly different global and line-of-sight column densities. Five sources are heavily obscured to Compton-thick. We comment on interesting sources revealed by our spectral modeling, including a candidate "naked" Sy2. After correcting for absorption, we find that the ratio of the rest-frame, 2-10 keV luminosity (L2-10 keV,in) to L[O iii] is 1.54 +/- 0.49 dex which is essentially identical to the mean Type 1 AGN value. The Fe K(alpha) luminosity is significantly correlated with L[O iii] but with substantial scatter. Finally, we do not find a trend between L2-10 keV,in and global or line-of-sight column density, between column density and redshift, between column density and scattering fraction, or between scattering fraction and redshift. Key words: galaxies: active - galaxies: Seyfert - X-rays: general

  2. Tibial lead determination by 99Tcm radiopharmaceutical x-ray fluorescence.

    Science.gov (United States)

    Mountford, P J; Green, S; Bradley, D A; Lewis, A D; Morgan, W D

    1994-04-01

    The feasibility of measuring tibial lead concentration by x-ray fluorescence with an internal 99Tcm labelled bone-seeking radiopharmaceutical was investigated using phantoms containing known values of lead concentration and 99Tcm activity. The minimum detectable concentration (MDC) at two standard deviations based on the counts in the Kalpha1 peak of 10.9 microg Pb ml(-1) was estimated to correspond to an MDC for an individual within a range of approximately 8-15 microg Pb (g bone mineral)(-1) if the counts from all four K x-ray peaks were included. Due to its much greater dose compared to an external source, the MDC of this internal source technique would have to be reduced before it could be used for measurements of occupationally or environmentally exposed individuals other than as an adjunct for a patient undergoing a bone scan. Methods of achieving such a reduction include increasing the acquisition time and the number of HPGE detectors, and optimizing the design of their collimators.

  3. Linearity discontinuities in Xe-filled X-ray microstrip detectors

    DEFF Research Database (Denmark)

    Zavattini, G.; Feroci, M.; Budtz-Jørgensen, Carl

    1997-01-01

    A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector. The mea......A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector....... The measured jump at the K-edge was (169 +/- 12)eV. It was also seen that K-alpha- and K-beta-decay channels produce different pulse heights for the same deposited energy. We find that the difference in energy between the calibration fines of the K-beta 2- and the K-beta 1.3-escape peaks is (93+/-12)eV whereas...... between the K-beta 1.3 and the K-alpha-escape peaks' calibration the energy gal is (69+/-7)eV....

  4. Linearity discontinuities in Xe-filled X-ray microstrip detectors

    DEFF Research Database (Denmark)

    Zavattini, G.; Feroci, M.; Budtz-Jørgensen, Carl

    1997-01-01

    A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector. The mea......A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector....... The measured jump at the K-edge was (169 +/- 12)eV. It was also seen that K-alpha- and K-beta-decay channels produce different pulse heights for the same deposited energy. We find that the difference in energy between the calibration fines of the K-beta 2- and the K-beta 1.3-escape peaks is (93+/-12)eV whereas...... between the K-beta 1.3 and the K-alpha-escape peaks' calibration the energy gal is (69+/-7)eV....

  5. An X-ray spectral model for clumpy tori in active galactic nuclei

    CERN Document Server

    Liu, Yuan

    2014-01-01

    We construct an X-ray spectral model for the clumpy torus in an active galactic nucleus (AGN) using Geant4, which includes the physical processes of the photoelectric effect, Compton scattering, Rayleigh scattering, $\\gamma$ conversion, fluorescence line, and Auger process. Since the electrons in the torus are expected to be bounded instead of free, the deviation of the scattering cross section from the Klein-Nishina cross section has also been included, which changes the X-ray spectra by up to 25% below $10$ keV. We have investigated the effect of the clumpiness parameters on the reflection spectra and the strength of the fluorescent line Fe K$\\alpha$. The volume filling factor of the clouds in the clumpy torus only slightly influences the reflection spectra, however, the total column density and the number of clouds along the line of sight significantly change the shapes and amplitudes of the reflection spectra. The effect of column density is similar to the case of a smooth torus, while a small number of c...

  6. Radio and X-ray emission from disc winds in radio-quiet quasars

    CERN Document Server

    Steenbrugge, K C; Kuncic, Z; Blundell, K M

    2010-01-01

    It has been proposed that the radio spectra of radio-quiet quasars is produced by free-free emission in the optically thin part of an accretion disc wind. An important observational constraint on this model is the observed X-ray luminosity. We investigate this constraint using a sample of PG radio-quiet quasars for which XMM-Newton EPIC spectra are available. Comparing the predicted and measured luminosities for 0.5, 2 and 5 keV, we conclude that all of the studied PG quasars require a large hydrogen column density absorber, requiring these quasars to be close to or Compton-thick. Such a large column density can be directly excluded for PG 0050+124, for which a high-resolution RGS spectrum exists. Further constraint on the column density for a further 19 out of the 21 studied PG quasars comes from the EPIC spectrum characteristics such as hard X-ray power-law photon index and the equivalent width of the Fe Kalpha line; and the small equivalent width of the C IV absorber present in UV spectra. For 2 sources: P...

  7. Akn 564 an unusual component in the X-ray spectra of NLSy1 galaxies

    CERN Document Server

    Turner, T J; Netzer, H; Netzer, Hagai

    1999-01-01

    We present an ASCA observation of the NLSy1 Ark 564. The X-ray light curve shows rapid variability, but no evidence for energy-dependence to these variations, within the 0.6 -- 10 keV bandpass. A strong (EW ~ 70 eV) spectral feature is observed close to 1 keV. A similar feature has been observed in TON S180 (another NLSy1) but has not been observed in broad-line Seyfert galaxies. The feature energy suggests a large contribution from Fe L-shell lines but its intensity is difficult to explain in terms of emission and/or absorption from photoionized gas. Models based on gas in thermal equilibrium with kT ~1 keV provide an alternative parameterization of the soft spectrum. The latter may be interpreted as the hot intercloud medium, undergoing rapid cooling and producing strong Fe L-shell recombination lines. In all cases the physical conditions are rather different from those observed in broad-line Seyferts. The hard X-ray spectrum shows a broad and asymmetric Fe Kalpha line of large equivalent width (~550 eV) wh...

  8. Spectral Modeling of the Charge-Exchange X-ray Emission from M82

    CERN Document Server

    Zhang, Shuinai; Ji, Li; Smith, Randall K; Foster, Adam R; Zhou, Xin

    2014-01-01

    It has been proposed that the charge exchange (CX) process at the interface between hot and cool interstellar gases could contribute significantly to the observed soft X-ray emission in star forming galaxies. We analyze the XMM-Newton/RGS spectrum of M82, using a newly developed CX model combined with a single-temperature thermal plasma to characterize the volume-filling hot gas. The CX process is largely responsible for not only the strongly enhanced forbidden lines of the K$\\alpha$ triplets of various He-like ions, but also good fractions of the Ly$\\alpha$ transitions of C VI (~87%), O VIII and N VII ($\\gtrsim$50%) as well. In total about a quarter of the X-ray flux in the RGS 6-30 \\AA\\ band originates in the CX. We infer an ion incident rate of $3\\times10^{51}\\,\\rm{s^{-1}}$ undergoing CX at the hot and cool gas interface, and an effective area of the interface as $\\sim2\\times10^{45}\\,{\\rm cm^2}$ that is one order of magnitude larger than the cross section of the global biconic outflow. With the CX contribu...

  9. 5.9 keV Mn K-shell X-ray luminosity from the decay of 55Fe in Type Ia supernova models

    CERN Document Server

    Seitenzahl, I R; Krauss, F; Sim, S A; Diehl, R; Elsaesser, D; Fink, M; Hillebrandt, W; Kromer, M; Maeda, K; Mannheim, K; Pakmor, R; Roepke, F K; Ruiter, A J; Wilms, J

    2014-01-01

    We show that the X-ray line flux of the Mn Kalpha line at 5.9 keV from the decay of 55Fe is a promising diagnostic to distinguish between Type Ia supernova (SN Ia) explosion models. Using radiation transport calculations, we compute the line flux for two 3D explosion models: a near-Chandrasekhar mass delayed detonation and a violent merger of two white dwarfs. Both models are based on solar metallicity zero-age main sequence progenitors. Due to explosive nuclear burning at higher density, the delayed-detonation model synthesises 3.5 times more radioactive 55Fe than the merger model. As a result, we find that the peak Mn Kalpha line flux of the delayed-detonation model exceeds that of the merger model by a factor of 4.5. Since in both models the 5.9 keV X-ray flux peaks five to six years after the explosion, a single measurement of the X-ray line emission at this time can place a constraint on the explosion physics that is complementary to those derived from earlier phase optical spectra or light curves. We pe...

  10. X-ray shout echoing through space

    Science.gov (United States)

    2004-01-01

    a flash of X-rays hi-res Size hi-res: 3991 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in hours. At their largest size, the rings would appear in the sky about five times smaller than the full moon. a flash of X-rays hi-res Size hi-res: 2153 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays (Please choose "hi-res" version for animation) XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in seconds. At their largest size, the rings would appear in the sky about five times smaller than the full moon. This echo forms when the powerful radiation of a gamma-ray burst, coming from far away, crosses a slab of dust in our Galaxy and is scattered by it, like the beam of a lighthouse in clouds. Using the expanding rings to precisely pin-point the location of this dust, astronomers can identify places where new stars and planets are likely to form. On 3 December 2003 ESA's observatory, Integral, detected a burst of gamma rays, lasting about 30 seconds, from the direction of a distant galaxy. Within minutes of the detection, thanks to a sophisticated alert network, many

  11. Polymer Compund Refractive Lenses for Hard X-ray Nanofocusing

    OpenAIRE

    Krywka, Christina; Last, Arndt; Marschall, Felix; Markus, Otto; Georgi, Sebastian; Mueller, Martin; Mohr, Jürgen

    2016-01-01

    Compound refractive lenses fabricated out of SU-8 negative photoresist have been used to generate a nanofocused, i.e. sub-μm sized X-ray focal spot at an X-ray nanodiffraction setup. X-ray microscopy and X-ray diffraction techniques have conceptually different demands on nanofocusing optical elements and so with the application of X-ray nanodiffraction in mind, this paper presents the results of an initial characterization of polymer lenses used as primary focusin...

  12. The Broad Iron K-alpha line of Cygnus X-1 as Seen by XMM-Newton in the EPIC-pn Modified Timing Mode

    Science.gov (United States)

    Duro, Refiz; Dauser, Thomas; Wilms, Jorn; Pottschmidt, Katja; Nowak, Michael A.; Fritz, Sonja; Kendziorra, Eckhard; Kirsch, Marcus G. F.; Reynolds, Christopher S.; Staubert, Rudiger

    2011-01-01

    We present the analysis of the broadened, flourescent iron K(alpha) line in simultaneous XMM-Newton and RXTE data from the black hole Cygnus X-I. The XMM-Newton data were taken in a modified version of the Timing Mode of the EPIC-pn camera. In this mode the lower energy threshold of the instrument is increased to 2.8 keV to avoid telemetry drop outs due to the brightness of the source, while at the same time preserving the signal to noise ratio in the Fe K(alpha) band. We find that the best-fit spectrum consists of the sum of an exponentially cut-off power-law and relativistically smeared, ionized reflection. The shape of the broadened Fe K(alpha) feature is due to strong Compton broadening combined with relativistic broadening. Assuming a standard, thin accretion disk, the black hole is close to maximally rotating. Key words. X-rays: binaries - black hole physics - gravitation

  13. A Relativistic Fe K-alpha Emission Line in the Intermediate Luminosity BeppoSAX Spectrum of the Galactic Microquasar V4641 Sgr

    CERN Document Server

    Miller, J M; in 't Zand, J J M; Reynolds, C S; Wijnands, R; Nowak, M A; Lewin, W H G

    2002-01-01

    Broad Fe K-alpha emission lines have recently been reported in a number of Galactic black holes. Such lines are useful accretion flow diagnostics because they may be produced at the inner accretion disk and shaped by relativistic effects, but in general they have only been observed at luminosities of L_X = 10^(37-38) erg/s in soft X-rays. The Galactic microquasar V4641 Sgr -- widely known for its 12.2 Crab (1.5-12 keV) outburst in 1999 September -- displayed low-level activity in 1999 March. BeppoSAX observed the source in this state and Fe K-alpha line emission was found (in 't Zand et al. 2000). In re-analyzing these data, we find strong evidence that the Fe K-alpha line profile is broadened. For the most likely values of the source distance and black hole mass measured by Orosz et al. (2001), our fits to the total spectrum indicate that the source was observed at a luminosity of L_X = 1.9 (+1.0, -0.8) * 10^(36) erg/s (2-10 keV), or L_(2-10)/L_(Eddington) = 1.8 (+0.9, -0.8) * 10^(-3). Advection-dominated ac...

  14. An X-ray and optical study of the ultracompact X-ray binary A1246-58

    NARCIS (Netherlands)

    Zand, J. J. M. in 't

    2008-01-01

    Results are discussed of an X-ray and optical observation campaign of the low-mass X-ray binary A 1246-58 performed with instruments on Satellite per Astronomia X (’BeppoSAX’), the Rossi X-ray Timing Explorer (RXTE), the X-ray Multi-mirror Mission (’XMM-Newton’), the Swift mission, and the Very Larg

  15. An X-ray and optical study of the ultracompact X-ray binary A 1246-58

    NARCIS (Netherlands)

    in 't Zand, J. J. M.; Bassa, C. G.; Keek, L.; Verbunt, F.; Mendez, M.; Markwardt, C. B.; Jonker, P.G.

    2008-01-01

    Results are discussed of an X-ray and optical observation campaign of the low-mass X-ray binary A 1246-58 performed with instruments on Satellite per Astronomia X ("BeppoSAX"), the Rossi X-ray Timing Explorer (RXTE), the X-ray Multi-mirror Mission ("XMM-Newton"), the Swift mission, and the Very Larg

  16. X-Ray Diffraction Analysis Program

    Science.gov (United States)

    Wiedemann, K. E.; Unnam, J.; Naidu, S. V. N.; Houska, C. R.

    1986-01-01

    SOPAD separates overlapping peaks and analyzes derivatives of X-ray diffraction data. SOPAD helps analyst get most information out of available diffraction data. SOPAD uses Marquardt-type nonlinear regression routine to refine initial estimates of individual peak positions, intensities, shapes, and half-widths.

  17. X-ray scattering from liquid interfaces

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Synchrotron radiation X-ray scattering is a useful tool for structural characterization of liquid interfaces.Specular refiectivity provides precise measurement of the interfacial widths and of the ordering of surfactants adsorbed to these interfaces. Diffuse scattering gives information on phase transitions and domain formation in surfactant monolayers and on interfacial fluctuations confined by and coupled across fluidic films.

  18. X-ray holography with atomic resolution

    Science.gov (United States)

    Tegze, Miklós; Faigel, Gyula

    1996-03-01

    DIFFRACTION methods for crystallographic structure determination suffer from the so-called 'phase problem'; a diffraction pattern provides intensity but not phase information for the scattered beams, and therefore cannot be uniquely inverted to obtain the crystal structure of a sample. Holographic methods1, on the other hand, offer a means of extracting both intensity and phase information. To be useful for crystallographic applications, holography must be implemented with radiation of sufficiently small wavelength to resolve atomic-scale features2. One method, electron-emission holography3-9, uses electron waves and is a powerful tool for studying surface structure; but it cannot image the internal structure of solids because of complications arising from the highly anisotropic nature of electron scattering processes. A proposed alternative method uses X-rays2,10-13, which scatter more isotropically than electrons. Here we demonstrate the efficacy of atomic-scale X-ray holography by obtaining direct images of the three-dimensional arrangement of strontium atoms in the cubic perovskite SrTiO3. With more intense synchrotron sources for illumination, and with the development of improved X-ray detectors, X-ray holography should become a powerful general technique for unambiguous structure determination in condensed matter systems.

  19. X-ray emission from red quasars

    Science.gov (United States)

    Bregman, J. N.; Glassgold, A. E.; Huggins, P. J.; Kinney, A. L.

    1985-01-01

    A dozen red quasars were observed with the Einstein Observatory in order to determine their X-ray properties. The observations show that for all these sources, the infrared-optical continuum is so steep that when extrapolated to higher frequencies, it passes orders of magnitude below the measured X-ray flux. The X-ray emission is better correlated with the radio than with the infrared flux, suggesting a connection between the two. By applying the synchrotron-self-Compton model to the data, it is found that the infrared-optical region has a size of 0.01 pc or more and a magnetic field more than 0.1 G, values considerably different than are found in the radio region. Unlike other quasars, the ionizing continuum is dominated by the X-ray emission. The peculiar line ratios seen in these objects can be understood with a photoionization model, provided that the photon to gas density ratio (ionization parameter) is an order of magnitude less than in typical quasars.

  20. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  1. Supernova remnants: the X-ray perspective

    NARCIS (Netherlands)

    Vink, J.

    2012-01-01

    Supernova remnants are beautiful astronomical objects that are also of high scientific interest, because they provide insights into supernova explosion mechanisms, and because they are the likely sources of Galactic cosmic rays. X-ray observations are an important means to study these objects. And i

  2. Reconstructing misaligned x-ray CT data

    Energy Technology Data Exchange (ETDEWEB)

    Divin, C. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-24

    Misalignment errors for x-ray computed tomography (CT) systems can manifest as artifacts and a loss of spatial and contrast resolution. To mitigate artifacts, significant effort is taken to determine the system geometry and minimizing any residual error in the system alignment. This project improved our ability to post-correct data which was acquired on a misaligned CT system.

  3. X-ray signals in renal osteopathy

    Energy Technology Data Exchange (ETDEWEB)

    Rieden, K.

    1984-10-01

    Chronic renal insufficiency is associated with metabolic disturbances which ultimately lead to typical, partly extremely painful changes in the skeletal system the longer the disease persists. Regular X-ray control of certain skeletal segments allows early detection of renal oesteopathy if the radiological findings described in this article are carefully scrutinised and interpreted.

  4. Spectroscopy and X-Ray Astronomy

    Science.gov (United States)

    Holt, Stephen S.

    2000-01-01

    The new x-ray astronomical observatories have sufficient spectroscopic capability to allow the determination of plasma conditions in the form of velocities, temperatures, densities, and turbulence parameters at levels that were previously unattainable. The utilization of these diagnostics are possible only if the atomic and plasma physics are well-enough understood to match the observational sensitivity.

  5. X-ray generation using carbon nanotubes

    Science.gov (United States)

    Parmee, Richard J.; Collins, Clare M.; Milne, William I.; Cole, Matthew T.

    2015-01-01

    Since the discovery of X-rays over a century ago the techniques applied to the engineering of X-ray sources have remained relatively unchanged. From the inception of thermionic electron sources, which, due to simplicity of fabrication, remain central to almost all X-ray applications, there have been few fundamental technological advances. However, with the emergence of ever more demanding medical and inspection techniques, including computed tomography and tomosynthesis, security inspection, high throughput manufacturing and radiotherapy, has resulted in a considerable level of interest in the development of new fabrication methods. The use of conventional thermionic sources is limited by their slow temporal response and large physical size. In response, field electron emission has emerged as a promising alternative means of deriving a highly controllable electron beam of a well-defined distribution. When coupled to the burgeoning field of nanomaterials, and in particular, carbon nanotubes, such systems present a unique technological opportunity. This review provides a summary of the current state-of-the-art in carbon nanotube-based field emission X-ray sources. We detail the various fabrication techniques and functional advantages associated with their use, including the ability to produce ever smaller electron beam assembles, shaped cathodes, enhanced temporal stability and emergent fast-switching pulsed sources. We conclude with an overview of some of the commercial progress made towards the realisation of an innovative and disruptive technology.

  6. The fast wavelet X-ray transform

    NARCIS (Netherlands)

    R.A. Zuidwijk; P.M. de Zeeuw (Paul)

    1999-01-01

    textabstractThe wavelet X-ray transform computes one-dimensional wavelet transforms along lines in Euclidian space in order to perform a directional time-scale analysis of functions in several variables. A fast algorithm is proposed which executes this transformation starting with values given on a

  7. Hard x-ray telescope mission

    DEFF Research Database (Denmark)

    Gorenstein, P.; Worrall, D.; Joensen, K.D.

    1996-01-01

    The Hard X-Ray Telescope was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity...

  8. Insights from soft X-rays

    DEFF Research Database (Denmark)

    Raaf, Jennifer; Issinger, Olaf-Georg; Niefind, Karsten

    2008-01-01

    The diffraction pattern of a protein crystal is normally a product of the interference of electromagnetic waves scattered by electrons of the crystalline sample. The diffraction pattern undergoes systematic changes in case additionally X-ray absorption occurs, meaning if the wavelength of the pri......The diffraction pattern of a protein crystal is normally a product of the interference of electromagnetic waves scattered by electrons of the crystalline sample. The diffraction pattern undergoes systematic changes in case additionally X-ray absorption occurs, meaning if the wavelength...... of the primary X-ray beam is relatively close to the absorption edge of selected elements of the sample. The resulting effects are summarized as "anomalous dispersion" and can be always observed with "soft" X-rays (wavelength around 2 A) since they match the absorption edges of sulfur and chlorine....... A particularly useful application of this phenomenon is the experimental detection of the sub-structures of the anomalous scatterers in protein crystals. We demonstrate this here with a crystal of a C-terminally truncated variant of human CK2alpha to which two molecules of the inhibitor 5,6-dichloro-1-beta...

  9. Outbursts in ultracompact X-ray binaries

    CERN Document Server

    Hameury, J -M

    2016-01-01

    Very faint X-ray binaries appear to be transient in many cases with peak luminosities much fainter than that of usual soft X-ray transients, but their nature still remains elusive. We investigate the possibility that this transient behaviour is due to the same thermal/viscous instability which is responsible for outbursts of bright soft X-ray transients, occurring in ultracompact binaries for adequately low mass-transfer rates. More generally, we investigate the observational consequences of this instability when it occurs in ultracompact binaries. We use our code for modelling the thermal-viscous instability of the accretion disc, assumed here to be hydrogen poor. We also take into account the effects of disc X-ray irradiation, and consider the impact of the mass-transfer rate on the outburst brightness. We find that one can reproduce the observed properties of both the very faint and the brighter short transients (peak luminosity, duration, recurrence times), provided that the viscosity parameter in quiesce...

  10. The Dynamical Theory of X Ray Diffraction

    Science.gov (United States)

    Balchin, A. A.; Whitehouse, C. R.

    1974-01-01

    Summarizes the Darwin theory of x-ray diffraction in thin crystals or crystals with a mosaic texture and its modified application to crystals with three-dimensional electrostatic dipoles. Indicates that the dynamical theory is brought into its present relevance by the improvement of single crystal growth techniques. (CC)

  11. X-ray voltabsorptometry on redox proteins

    Energy Technology Data Exchange (ETDEWEB)

    Ascone, Isabella [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , P.le A. Moro 5, 00185 Rome (Italy) and LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France)]. E-mail: i.ascone@caspur.it; Zamponi, Silvia [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy); Cognigni, Andrea [LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France); Marmocchi, Franco [Dipartimento di Biologia Molecolare, Cellulare e Animale, Universita di Camerino, Via Camerini, 1 Camerino (Italy); Marassi, Roberto [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy)

    2005-04-15

    Biological X-ray absorption spectroscopy (BioXAS) is able to describe the metal environment in a metalloprotein and is sensitive to metal oxidation state. Coupling of BioXAS and electrochemistry permits the characterization of different oxidation states and avoids uncontrolled protein redox state changes due to X-ray beam irradiation. XAS spectroelectrochemistry requires electrochemical cells specifically designed to meet the requirements of both XAS measurements and electrochemical effectiveness in potential control. In this context, this paper describes a new cell tested with different types of working electrodes developed for BioXAS, in particular for in situ studies of redox proteins. The XAS electrochemical measurements of a relatively high-molecular-weight protein (Cu,Zn superoxide dismutase) for which it is difficult to observe direct electrochemistry have been achieved. New working electrodes, capable of fast and unmediated electron transfer, are described. The cell permits to isolate protein redox states and to measure X-ray absorption intensity during a potential scan (X-ray voltabsorptometry)

  12. Fourier techniques in X-ray timing

    NARCIS (Netherlands)

    M. van der Klis

    1988-01-01

    Basic principles of Fourier techniques often used in X-ray time series analysis are reviewed. The relation between the discrete Fourier transform and the continuous Fourier transform is discussed to introduce the concepts of windowing and aliasing. The relation is derived between the power spectrum

  13. X-ray spectroscopy of manganese clusters

    Energy Technology Data Exchange (ETDEWEB)

    Grush, M.M. [Univ. of California, Davis, CA (United States). Dept. of Applied Science]|[Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

    1996-06-01

    Much of this thesis represents the groundwork necessary in order to probe Mn clusters more productively than with conventional Mn K-edge XAS and is presented in Part 1. Part 2 contains the application of x-ray techniques to Mn metalloproteins and includes a prognosis at the end of each chapter. Individual Mn oxidation states are more readily distinguishable in Mn L-edge spectra. An empirical mixed valence simulation routine for determining the average Mn oxidation state has been developed. The first Mn L-edge spectra of a metalloprotein were measured and interpreted. The energy of Mn K{beta} emission is strongly correlated with average Mn oxidation state. K{beta} results support oxidation states of Mn(III){sub 2}(IV){sub 2} for the S{sub 1} state of Photosystem II chemical chemically reduced preparations contain predominantly Mn(II). A strength and limitation of XAS is that it probes all of the species of a particular element in a sample. It would often be advantageous to selectively probe different forms of the same element. The first demonstration that chemical shifts in x-ray fluorescence energies can be used to obtain oxidation state-selective x-ray absorption spectra is presented. Spin-dependent spectra can also be used to obtain a more simplified picture of local structure. The first spin-polarized extended x-ray absorption fine structure using Mn K{beta} fluorescence detection is shown.

  14. Exploring subluminous X-ray binaries

    NARCIS (Netherlands)

    Degenaar, N.D.

    2010-01-01

    Halfway the twentieth century, technological developments made it possible to carry detection instruments outside the absorbing layers of the Earth’s atmosphere onboard rockets and satellites. This opened up the opportunity to detect the emission from celestial objects at X-ray wavelengths, thereby

  15. X-ray Pulsation Searches with NICER

    Science.gov (United States)

    Ray, Paul S.; Arzoumanian, Zaven

    2016-04-01

    The Neutron Star Interior Composition Explorer (NICER) is an X-ray telescope with capabilities optimized for the study of the structure, dynamics, and energetics of neutron stars through high-precision timing of rotation- and accretion-powered pulsars in the 0.2-12 keV band. It has large collecting area (twice that of the XMM-Newton EPIC-pn camera), CCD-quality spectral resolution, and high-precision photon time tagging referenced to UTC through an onboard GPS receiver. NICER will begin its 18-month prime mission as an attached payload on the International Space Station around the end of 2016. I will describe the science planning for the pulsation search science working group, which is charged with searching for pulsations and studying flux modulation properties of pulsars and other neutron stars. A primary goal of our observations is to detect pulsations from new millisecond pulsars that will contribute to NICER’s studies of the neutron star equation of state through pulse profile modeling. Beyond that, our working group will search for pulsations in a range of source categories, including LMXBs, new X-ray transients that might be accreting millisecond pulsars, X-ray counterparts to unassociated Fermi LAT sources, gamma-ray binaries, isolated neutron stars, and ultra-luminous X-ray sources. I will survey our science plans and give an overview of our planned observations during NICER’s prime mission.

  16. X-ray microscopy of human malaria

    Energy Technology Data Exchange (ETDEWEB)

    Magowan, C.; Brown, J.T.; Mohandas, N.; Meyer-Ilse, W. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    Associations between intracellular organisms and host cells are complex and particularly difficult to examine. X-ray microscopy provides transmission images of subcellular structures in intact cells at resolutions superior to available methodologies. The spatial resolution is 50-60nm with a 1 micron depth of focus, superior to anything achievable with light microscopy. Image contrast is generated by differences in photoelectric absorption by the atoms in different areas (i.e. subcellular structures) throughout the full thickness of the sample. Absorption due to carbon dominates among all the elements in the sample at 2.4 nm x-ray wavelength. Thus images show features or structures, in a way not usually seen by other types of microscopy. The authors used soft x-ray microscopy to investigate structural development of Plasmodium falciparum malaria parasites in normal and genetically abnormal erythrocytes, and in infected erythrocytes treated with compounds that have anti-malarial effects. X-ray microscopy showed newly elaborated structures in the cytosol of unstained, intact erythrocytes, redistribution of mass (carbon) in infected erythrocytes, and aberrant parasite morphology. Better understanding of the process of intracellular parasite maturation and the interactions between the parasite and its host erythrocyte can help define new approaches to the control of this deadly disease.

  17. Soft X-ray follow-up of five hard X-ray emitters

    CERN Document Server

    Pavan, L; Ferrigno, C; Falanga, M; Campana, S; Paltani, S; Stella, L; Walter, R

    2013-01-01

    We studied the soft-X-ray emission of five hard-X sources: IGR J08262-3736, IGR J17354-3255, IGR J16328-4726, SAX J1818.6-1703 and IGR J17348-2045. These sources are: a confirmed supergiant high mass X-ray binary (IGR J08262-3736); candidates (IGR J17354-3255, IGR J16328- 4726) and confirmed (SAX J1818.6-1703) supergiant fast X-ray transients; IGR J17348-2045 is one of the as-yet unidentified objects discovered with INTEGRAL. Thanks to dedicated XMM-Newton observations, we obtained the first detailed soft X-ray spectral and timing study of IGR J08262-3736. The results obtained from the observations of IGR J17354-3255 and IGR J16328-4726 provided further support in favor of their association with the class of Supergiant Fast X-ray Transients. SAX J1818.6-1703, observed close to phase 0.5, was not detected by XMM-Newton, thus supporting the idea that this source reaches its lowest X-ray luminosity (~10^32 erg/s) around apastron. For IGR J17348-2045 we identified for the first time the soft X-ray counterpart and...

  18. X-ray Chirped Pulse Amplification: towards GW Soft X-ray Lasers

    Directory of Open Access Journals (Sweden)

    Marta Fajardo

    2013-07-01

    Full Text Available Extensive modeling of the seeding of plasma-based soft X-ray lasers is reported in this article. Seminal experiments on amplification in plasmas created from solids have been studied in detail and explained. Using a transient collisional excitation scheme, we show that a 18 µJ, 80 fs fully coherent pulse is achievable by using plasmas pumped by a compact 10 Hz laser. We demonstrate that direct seeding of plasmas created by nanosecond lasers is not efficient. Therefore, we propose and fully study the transposition to soft X-rays of the Chirped Pulse Amplification (CPA technique. Soft X-ray pulses with energy of 6 mJ and 200 fs duration are reachable by seeding plasmas pumped by compact 100 J, sub-ns, 1 shot/min lasers. These soft X-ray lasers would reach GW power, corresponding to an increase of 100 times as compared to the highest peak power achievable nowadays in the soft X-ray region (30 eV–1 keV. X-ray CPA is opening new horizon for soft x-ray ultra-intense sources.

  19. X-ray induced photoacoustic tomography

    Science.gov (United States)

    Xiang, Liangzhong; Han, Bin; Carpenter, Colin; Pratx, Guillem; Kuang, Yu; Xing, Lei

    2013-03-01

    X-ray induced photoacoustic tomography, also called X-ray acoustic computer tomography (XACT) is investigated in this paper. Short pulsed (μs-range) X-ray beams from a medical linear accelerator were used to generate ultrasound. The ultrasound signals were collected with an ultrasound transducer (500 KHz central frequency) positioned around an object. The transducer, driven by a computer-controlled step motor to scan around the object, detected the resulting acoustic signals in the imaging plane at each scanning position. A pulse preamplifier, with a bandwidth of 20 KHz-2 MHz at -3 dB, and switchable gains of 40 and 60 dB, received the signals from the transducer and delivered the amplified signals to a secondary amplifier. The secondary amplifier had bandwidth of 20 KHz-30 MHz at -3 dB, and a gain range of 10-60 dB. Signals were recorded and averaged 128 times by an oscilloscope. A sampling rate of 100 MHz was used to record 2500 data points at each view angle. One set of data incorporated 200 positions as the receiver moved 360°. The x-ray generated acoustic image was then reconstructed with the filtered back projection algorithm. The twodimensional XACT images of the lead rod embedded in chicken breast tissue were found to be in good agreement with the shape of the object. This new modality may be useful for a number of applications, such as providing the location of a fiducial, or monitoring x-ray dose distribution during radiation therapy.

  20. X-ray spectral properties of accretion discs in X-ray binaries

    Energy Technology Data Exchange (ETDEWEB)

    White, N.E.; Stella, L.; Parmar, A.N.

    1988-01-01

    Exosat observations are used to compare the spectral properties of the persistent emission from a number of X-ray burst sources, high-luminosity low-mass X-ray binaries (LMXRB) and galactic black hole candidates with various models for X-ray emission from an accretion disk surrounding a compact object in a binary system. It is shown that only a Comptonization model provides a good fit to all of the spectra considered. The fits to the spectra of the high-luminosity LMXRB systems necessitate an additional blackbody component with a luminosity 16 to 34 percent that from the Comptonized component. 82 references.

  1. Elimination of X-Ray Diffraction through Stimulated X-Ray Transmission.

    Science.gov (United States)

    Wu, B; Wang, T; Graves, C E; Zhu, D; Schlotter, W F; Turner, J J; Hellwig, O; Chen, Z; Dürr, H A; Scherz, A; Stöhr, J

    2016-07-08

    X-ray diffractive imaging with laterally coherent x-ray free-electron laser (XFEL) pulses is increasingly utilized to obtain ultrafast snapshots of matter. Here we report the amazing disappearance of single-shot charge and magnetic diffraction patterns recorded with resonantly tuned, narrow bandwidth XFEL pulses. Our experimental results reveal the exquisite sensitivity of single-shot charge and magnetic diffraction patterns of a magnetic film to the onset of field-induced stimulated elastic x-ray forward scattering. The loss in diffraction contrast, measured over 3 orders of magnitude in intensity, is in remarkable quantitative agreement with a recent theory that is extended to include diffraction.

  2. Energy-dispersive X-ray diffraction mapping on a benchtop X-ray fluorescence system

    OpenAIRE

    Lane, D W.; Nyombi, A.; Shackel, J.

    2014-01-01

    A method for energy-dispersive X-ray diffraction mapping is presented, using a conventional low-power benchtop X-ray fluorescence spectrometer, the Seiko Instruments SEA6000VX. Hyper spectral X-ray maps with a 10µm step size were collected from polished metal surfaces, sectioned Bi, Pb and steel shot gun pellets. Candidate diffraction lines were identified by eliminating those that matched a characteristic line for an element and those predicted for escape peaks, sum peaks, and Rayleigh and C...

  3. Microfocussing of synchrotron X-rays using X-ray refractive lens developed at Indus-2 deep X-ray lithography beamline

    Indian Academy of Sciences (India)

    V P Dhamgaye; M K Tiwari; K J S Sawhney; G S Lodha

    2014-07-01

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance sources are compared.

  4. Principles of femtosecond X-ray/optical cross-correlation with X-ray induced transient optical reflectivity in solids

    OpenAIRE

    Eckert, S.; Beye, M.; Schlotter, W. F.; Dakovski, G. L.; Khalil, M.; Huse, N.; Föhlisch, A.; Pietzsch, A.; Quevedo, W.; Hantschmann, M.; Ochmann, M.; Ross, M.; Minitti, M. P.; Turner, J. J.; Moeller, S. P.

    2015-01-01

    The discovery of ultrafast X-ray induced optical reflectivity changes enabled the development of X-ray/optical cross correlation techniques at X-ray free electron lasers worldwide. We have now linked through experiment and theory the fundamental excitation and relaxation steps with the transient optical properties in finite solid samples. Therefore, we gain a thorough interpretation and an optimized detection scheme of X-ray induced changes to the refractive index and the X-ray/optical cross ...

  5. Principles of femtosecond X-ray/optical cross-correlation with X-ray induced transient optical reflectivity in solids

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, S., E-mail: sebastian.eckert@helmholtz-berlin.de, E-mail: martin.beye@helmholtz-berlin.de; Beye, M., E-mail: sebastian.eckert@helmholtz-berlin.de, E-mail: martin.beye@helmholtz-berlin.de; Pietzsch, A.; Quevedo, W.; Hantschmann, M. [Institute for Methods and Instrumentation in Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Ochmann, M.; Huse, N. [Institute for Nanostructure and Solid State Physics, University of Hamburg, Jungiusstr. 11, 20355 Hamburg, Germany and Max Planck Institute for the Structure and Dynamics of Matter, Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg (Germany); Ross, M.; Khalil, M. [Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195 (United States); Minitti, M. P.; Turner, J. J.; Moeller, S. P.; Schlotter, W. F.; Dakovski, G. L. [LCLS, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Föhlisch, A. [Institute for Methods and Instrumentation in Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Str. 24/25, 14476 Potsdam (Germany)

    2015-02-09

    The discovery of ultrafast X-ray induced optical reflectivity changes enabled the development of X-ray/optical cross correlation techniques at X-ray free electron lasers worldwide. We have now linked through experiment and theory the fundamental excitation and relaxation steps with the transient optical properties in finite solid samples. Therefore, we gain a thorough interpretation and an optimized detection scheme of X-ray induced changes to the refractive index and the X-ray/optical cross correlation response.

  6. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  7. K$\\alpha$ iron line profile from accretion disks around regular and singular exotic compact objects

    CERN Document Server

    Bambi, Cosimo

    2013-01-01

    The nature of the super-massive black hole candidates in galactic nuclei can be tested by analyzing the profile of the K$\\alpha$ iron line observed in their X-ray spectrum. In this paper, we consider the possibility that the spacetime in the immediate vicinity of these objects may be described by some non vacuum exact solutions of Einstein's equations resulting as the end-state of gravitational collapse. The vacuum far away portion of the spacetime is described by the Schwarzschild metric, while the interior part may be either regular or have a naked singularity at the center. The iron line generated around this class of objects has specific features, which can be used to distinguish such objects from Kerr black holes. In particular, their iron line cannot have the characteristic low-energy tail of the line generated from accretion disks around fast-rotating Kerr black holes. We can thus conclude that the super-massive black hole candidates whose spin parameter has been estimated to be close to 1 assuming the...

  8. Iron K$\\alpha$ line of Kerr black holes with scalar hair

    CERN Document Server

    Ni, Yueying; Cardenas-Avendano, Alejandro; Bambi, Cosimo; Herdeiro, Carlos A R; Radu, Eugen

    2016-01-01

    Recently, a family of hairy black holes in 4-dimensional Einstein gravity minimally coupled to a complex, massive scalar field was discovered (Herdeiro & Radu, 2014). Besides the mass $M$ and spin angular momentum $J$, these objects are characterized by a Noether charge $Q$, measuring the amount of scalar hair, which is not associated to a Gauss law and cannot be measured at spatial infinity. Introducing a dimensionless scalar hair parameter $q$, ranging from 0 to 1, we recover (a subset of) Kerr black holes for $q=0$ and a family of rotating boson stars for $q=1$. In the present paper, we explore the possibility of measuring $q$ for astrophysical black holes with current and future X-ray missions. We study the iron K$\\alpha$ line expected in the reflection spectrum of such hairy black holes and we simulate observations with Suzaku and eXTP. As a proof of concept we show, by analyzing a sample of hairy black holes, that current observations can already rule out a region in the space of solutions, because ...

  9. Determination of low concentrations of thorium in geological materials by X-ray fluorescence; Determinacion de bajas concentraciones de torio en materiales geologicos mediante fluorescencia de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M.; Bayon, A.

    1981-07-01

    An X-ray fluorescence method for the determination of thorium in geological samples down to 2 ppm ThO{sub 2} has been developed. To achieve this determination limit an exposed area of the sample 42.5 mm in diameter is used, working with a molybdenum target tube operated at 90 kV and 30 m A. Corrections for background and line interference of the Rb K{alpha} radiation have been carefully considered and empirical correction coefficients calculated. (Author) 3 refs.

  10. X-Ray Scattering Applications Using Pulsed X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Larson, B.C.

    1999-05-23

    Pulsed x-ray sources have been used in transient structural phenomena investigations for over fifty years; however, until the advent of synchrotrons sources and the development of table-top picosecond lasers, general access to ligh temporal resolution x-ray diffraction was relatively limited. Advances in diffraction techniques, sample excitation schemes, and detector systems, in addition to IncEased access to pulsed sources, have ld tO what is now a diverse and growing array of pulsed-source measurement applications. A survey of time-resolved investigations using pulsed x-ray sources is presented and research opportunities using both present and planned pulsed x-ray sources are discussed.

  11. Laser-based X-ray and electron source for X-ray fluorescence studies

    CERN Document Server

    Brozas, F Valle; Roso, L; Conde, A Peralta

    2016-01-01

    In this work we present a modification to conventional X-rays fluorescence using electrons as excitation source, and compare it with the traditional X-ray excitation for the study of pigments. For this purpose we have constructed a laser-based source capable to produce X-rays as well as electrons. Because of the large penetration depth of X-rays, the collected fluorescence signal is a combination of several material layers of the artwork under study. However electrons are stopped in the first layers allowing therefore a more superficial analysis. We show that the combination of both excitation sources can provide extremely valuable information about the structure of the artwork.

  12. Soft X-ray Absorbers Enabling Study of the Diffuse X-ray Background Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Absorbers for soft x-rays need to be made thinner and with larger area, to collect more photons, and with minimal number of support stems. However, the structure is...

  13. Calculation of x-ray scattering patterns from nanocrystals at high x-ray intensity

    CERN Document Server

    Abdullah, Malik Muhammad; Son, Sang-Kil; Santra, Robin

    2016-01-01

    We present a generalized method to describe the x-ray scattering intensity of the Bragg spots in a diffraction pattern from nanocrystals exposed to intense x-ray pulses. Our method involves the subdivision of a crystal into smaller units. In order to calculate the dynamics within every unit we employ a Monte-Carlo (MC)-molecular dynamics (MD)-ab-initio hybrid framework using real space periodic boundary conditions. By combining all the units we simulate the diffraction pattern of a crystal larger than the transverse x-ray beam profile, a situation commonly encountered in femtosecond nanocrystallography experiments with focused x-ray free-electron laser radiation. Radiation damage is not spatially uniform and depends on the fluence associated with each specific region inside the crystal. To investigate the effects of uniform and non-uniform fluence distribution we have used two different spatial beam profiles, gaussian and flattop.

  14. Towards brilliant, compact x-ray sources: a new x-ray photonic device

    Science.gov (United States)

    Scherer, Brian; Mandal, Sudeep; Salisbury, Joshua; Edic, Peter; Hopkins, Forrest; Lee, Susanne M.

    2017-05-01

    General Electric has designed an innovative x-ray photonic device that concentrates a polychromatic beam of diverging x-rays into a less divergent, parallel, or focused x-ray beam. The device consists of multiple, thin film multilayer stacks. X-rays incident on a given multilayer stack propagate within a high refractive index transmission layer while undergoing multiple total internal reflections from a novel, engineered multilayer containing materials of lower refractive index. Development of this device could lead to order-of-magnitude flux density increases, over a large broadband energy range from below 20 keV to above 300 keV. In this paper, we give an overview of the device and present GE's progress towards fabricating prototype devices.

  15. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    This thesis presents thework on combining complementary X-rays techniques for studying the structures of proteins and other biomaterials, and consists of three different projects: (i) Characterization of protein powders with X-ray powder diffraction (XRPD). (ii) The combination of X......-ray crystallography and X-ray absorption spectroscopy (XAS) applied to studying different hexameric insulin conformations. (iii) The structures of polymorphs of strontium ranelate and the distribution of strontium in bone tissue. A procedure for fast identification and verification of protein powders using XRPD...... was developed and tested on micro-crystals of lysozyme and insulin. Different protein crystal forms were identified by comparing experimental powder diffraction patternswith patterns calculated from PDB coordinates. The key factor to bring the calculated patterns in agreement with the observed patterns...

  16. X-ray studies of ion adsorption at charged titania-electrolyte interfaces

    Science.gov (United States)

    Kohli, Vaibhav

    Interaction of counter ions with charged solid-electrolyte interfaces plays an important role in wide ranging chemical and environmental processes including ion adsorption, colloidal stability, and electrokinetic transport. A complete molecular-level characterization of the counter-ion profile near the interface is critical to understanding the interfacial reactivity. Resonant anomalous X-ray reflectivity (RAXR), and crystal truncation rod (CTR) techniques were used to directly measure the vertical density profiles of Rb+ and Sr2+ at the rutile TiO2(110)-electrolyte interface. These results are the first experimental confirmation of a recent molecular dynamics prediction that the adsorbed ion structure is distributed between multiple inner-sphere sites (i.e., tetra-dentate and bi-dentate) rather than a single site (i.e., tetra-dentate) as thought from previous investigations. Rb+ and Sr2+ are found to be specifically-adsorbed with coverages of 0.080+/-0.003 and 0.40+/-0.07 monolayers respectively, and average heights of 3.72+/-0.03 A and 3.05+/-0.16 A above the interface respectively. A new generalized model-independent approach was developed for the analysis of long-period x-ray standing waves (XSW) data. The approach is applicable to various reflection geometries, including simple x-ray mirrors, and multi-layers, and is valid for XSW in an attenuating medium. The formalism allows direct extraction of the amplitudes and phases of the elemental structure factor from the measured long-period XSW data, leading to a fully model-independent recovery of the elemental distribution. The method is demonstrated by extracting the 1D profile of Ti normal to the surface for a TiO2/Si/Mo tri-layer sample on a Si substrate, using Ti-Kalpha fluorescence yield measured in ex situ and in situ environments. Using long period XSW, X-ray fluorescence (XRF) and X-ray reflectivity (XR), it is shown that titania nanofilms grown by atomic layer deposition (ALD) exhibit significantly

  17. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  18. CHANDRA X-RAY OBSERVATIONS OF THE REDSHIFT 1.53 RADIO-LOUD QUASAR 3C 270.1

    Energy Technology Data Exchange (ETDEWEB)

    Wilkes, Belinda J.; Lal, Dharam V.; Willner, S. P.; Ashby, M. L. N.; Fazio, G. G. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Worrall, D. M.; Birkinshaw, Mark [HH Wills Physics Laboratory, University of Bristol, Bristol (United Kingdom); Haas, Martin; Chini, Rolf [Astronomisches Institut, Ruhr-University, Bochum (Germany); Antonucci, Robert [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Avara, Mark [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Barthel, Peter [Kapteyn Astronomical Institute, University of Groningen, Groningen (Netherlands); Hardcastle, Martin [School of Physics and Astronomy, University of Hertfordshire, Hatfield (United Kingdom); Lawrence, Charles [JPL, Pasadena, CA 91109 (United States); Leipski, Christian [MPIA, Heidelberg (Germany); Ogle, Patrick [Spitzer Science Center, Caltech, Pasadena, CA 91125 (United States); Schulz, Bernhard [IPAC, Caltech, Pasadena, CA 91125 (United States)

    2012-01-20

    Chandra X-ray observations of the high redshift (z = 1.532) radio-loud quasar 3C 270.1 in 2008 February show the nucleus to have a power-law spectrum, {Gamma} = 1.66 {+-} 0.08, typical of a radio-loud quasar, and a marginally detected Fe K{alpha} emission line. The data also reveal extended X-ray emission, about half of which is associated with the radio emission from this source. The southern emission is co-spatial with the radio lobe and peaks at the position of the double radio hot spot. Modeling this hot spot, including Spitzer upper limits, rules out synchrotron emission from a single power-law population of electrons, favoring inverse Compton emission with a field of {approx}11 nT, roughly a third of the equipartition value. The northern emission is concentrated close to the location of a 40 Degree-Sign bend where the radio jet is presumed to encounter an external medium. It can be explained by inverse Compton emission involving cosmic microwave background photons with a field of {approx}3 nT, a factor of 7-10 below the equipartition value. The remaining, more diffuse X-ray emission is harder (HR = -0.09 {+-} 0.22). With only 22.8 {+-} 5.6 counts, the spectral form cannot be constrained. Assuming thermal emission with a temperature of 4 keV yields an estimate for the luminosity of 1.8 Multiplication-Sign 10{sup 44} erg s{sup -1}, consistent with the luminosity-temperature relation of lower-redshift clusters. However, deeper Chandra X-ray observations are required to delineate the spatial distribution and better constrain the spectrum of the diffuse emission to verify that we have detected X-ray emission from a high-redshift cluster.

  19. The ITER core imaging x-ray spectrometer: x-ray calorimeter performance.

    Science.gov (United States)

    Beiersdorfer, P; Brown, G V; Clementson, J; Dunn, J; Morris, K; Wang, E; Kelley, R L; Kilbourne, C A; Porter, F S; Bitter, M; Feder, R; Hill, K W; Johnson, D; Barnsley, R

    2010-10-01

    We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

  20. X-RAY POLARIZATION FROM HIGH-MASS X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Kallman, T. [NASA/GSFC, Code 662, Greenbelt, MD 20771 (United States); Dorodnitsyn, A. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Blondin, J. [Department of Physics, North Carolina State University, Raleigh, NC 27695-8202 (United States)

    2015-12-10

    X-ray astronomy allows study of objects that may be associated with compact objects, i.e., neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically nonspherical, and likely noncircular when projected on the sky. Polarization allows study of such geometric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. Potential targets for future X-ray polarization observations are the high-mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early-type star. In this paper we show that X-ray polarization from HMXBs has a distinct signature that depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclipse the net polarization is expected to be small or zero if the wind is circularly symmetric around the line of centers. Resonance line scattering increases the scattering fraction, often by large factors, over the energy band spanned by resonance lines. Real winds are not expected to be spherically symmetric, or circularly symmetric around the line of centers, owing to the combined effects of the compact object gravity and ionization on the wind hydrodynamics. A sample calculation shows that this creates polarization fractions ranging up to tens of percent at mid-eclipse.