WorldWideScience

Sample records for ka current pulses

  1. Atomization and merging of two Al and W wires driven by a 1 kA, 10 ns current pulse

    Science.gov (United States)

    Wu, Jian; Li, Xingwen; Lu, Yihan; Lebedev, S. V.; Yang, Zefeng; Jia, Shenli; Qiu, Aici

    2016-11-01

    Possibility of preconditioning of wires in wire array Z-pinch loads by an auxiliary low-level current pulse was investigated in experiments with two aluminum or two polyimide-coated tungsten wires. It was found that the application of a 1 kA, 10 ns current pulse could convert all the length of the Al wires (1 cm long, 15 μm diameter) and ˜70% of length of the W wires (1 cm long, 15 μm diameter, 2 μm polyimide coating) into a gaseous state via ohmic heating. The expansion and merging of the wires, positioned at separations of 1-3 mm, were investigated with two-wavelength (532 nm and 1064 nm) laser interferometry. The gasified wire expanded freely in a vacuum and its density distribution at different times could be well described using an analytic model for the expansion of the gas into vacuum. Under an energy deposition around its atomization enthalpy of the wire material, the aluminum vapor column had an expansion velocity of 5-7 km/s, larger than the value of ˜4 km/s from tungsten wires. The dynamic atomic polarizabilities of tungsten for 532 nm and 1064 nm were also estimated.

  2. Test results of 12/18 kA ReBCO coated conductor current leads

    Science.gov (United States)

    Kovalev, I. A.; Surin, M. I.; Naumov, A. V.; Novikov, M. S.; Novikov, S. I.; Ilin, A. A.; Polyakov, A. V.; Scherbakov, V. I.; Shutova, D. I.

    2017-07-01

    A pair of hybrid current leads (brass + stacked & soldered ReBCO tapes) rated for 12 kA in steady state and for up to 18 kA at pulsed over current conditions was designed, developed and tested at NRC ;Kurchatov Institute; (NRC ;KI;). During the experiment at LN2 temperature, the current leads (CLs) were successfully charged with 18 kA at 100 A/s ramp rate. To date, as far as we know, this is the highest current capacity achieved for 2G HTS current leads. The feasibility of ;stack-and-soldering technique; for 10 kA+ class coated conductor CLs for accelerators and fusion was demonstrated. This paper gives an overview of the leads design and presents the preliminary test results. Detailed studies of magnetic properties and current sharing process for the stacked and staggered HTS joints are also reported.

  3. 20 kA PFN capacitor bank with solid-state switching. [pulse forming network for plasma studies

    Science.gov (United States)

    Posta, S. J.; Michels, C. J.

    1973-01-01

    A compact high-current pulse-forming network capacitor bank using paralleled silicon controlled rectifiers as switches is described. The maximum charging voltage of the bank is 1kV and maximum load current is 20 kA. The necessary switch equalization criteria and performance with dummy load and an arc plasma generator are described.

  4. THE CURRENT STAR FORMATION RATE OF K+A GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Danielle M. [Department of Astronomy, University of Wisconsin-Madison, 475 North Charter Street, Madison, WI 53706 (United States); Ridgway, Susan E.; De Propris, Roberto [Cerro Tololo Inter-American Observatory Casilla 603, La Serena (Chile); Goto, Tomotsugu, E-mail: nielsen@astro.wisc.edu [Dark Cosmology Center, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, 2100 Copenhagen O (Denmark)

    2012-12-20

    We derive the stacked 1.4 GHz flux from the FIRST survey for 811 K+A galaxies selected from the Sloan Digital Sky Survey Data Release 7. For these objects we find a mean flux density of 56 {+-} 9 {mu}Jy. A similar stack of radio-quiet white dwarfs yields an upper limit of 43 {mu}Jy at a 5{sigma} significance to the flux in blank regions of the sky. This implies an average star formation rate of 1.6 {+-} 0.3 M{sub Sun} yr{sup -1} for K+A galaxies. However, the majority of the signal comes from {approx}4% of K+A fields that have aperture fluxes above the 5{sigma} noise level of the FIRST survey. A stack of the remaining galaxies shows little residual flux consistent with an upper limit on star formation of 1.3 M{sub Sun} yr{sup -1}. Even for a subset of 456 'young' (spectral ages <250 Myr) K+A galaxies, we find that the stacked 1.4 GHz flux is consistent with no current star formation. Our data suggest that the original starburst has been terminated in the majority of K+A galaxies, but that this may represent part of a duty cycle where a fraction of these galaxies may be active at a given moment with dusty starbursts and active galactic nuclei being present.

  5. A new low-cost 10 ns pulsed Ka-band radar

    Science.gov (United States)

    Eskelinen, Pekka; Ylinen, Juhana

    2011-07-01

    Two Gunn oscillators, conventional intermediate frequency building blocks, and a modified GaAs diode detector are combined to form a portable monostatic 10 ns instrumentation radar for outdoor Ka-band radar cross section measurements. At 37.8 GHz the radar gives +20 dBm output power and its tangential sensitivity is -76 dBm. Processing bandwidth is 125 MHz, which also allows for some frequency drift in the Gunn devices. Intra-pulse frequency chirp is less than 15 MHz. All functions are steered by a microcontroller. First measurements convince that the construction has a reasonable ability to reduce close-to-ground surface clutter and gives an effective way of resolving target detail. This is beneficial especially when amplitude fluctuations disturb measurements with longer pulses. The new unit operates on 12 V dc, draws a current of less than 3 A, and weighs 5 kg.

  6. Fast initial continuous current pulses versus return stroke pulses in tower-initiated lightning

    Science.gov (United States)

    Azadifar, Mohammad; Rachidi, Farhad; Rubinstein, Marcos; Rakov, Vladimir A.; Paolone, Mario; Pavanello, Davide; Metz, Stefan

    2016-06-01

    We present a study focused on pulses superimposed on the initial continuous current of upward negative discharges. The study is based on experimental data consisting of correlated lightning current waveforms recorded at the instrumented Säntis Tower in Switzerland and electric fields recorded at a distance of 14.7 km from the tower. Two different types of pulses superimposed on the initial continuous current were identified: (1) M-component-type pulses, for which the microsecond-scale electric field pulse occurs significantly earlier than the onset of the current pulse, and (2) fast pulses, for which the onset of the field matches that of the current pulse. We analyze the currents and fields associated with these fast pulses (return-stroke type (RS-type) initial continuous current (ICC) pulses) and compare their characteristics with those of return strokes. A total of nine flashes containing 44 RS-type ICC pulses and 24 return strokes were analyzed. The median current peaks associated with RS-type ICC pulses and return strokes are, respectively, 3.4 kA and 8 kA. The associated median E-field peaks normalized to 100 km are 1.5 V/m and 4.4 V/m, respectively. On the other hand, the electric field peaks versus current peaks for the two data sets (RS-type ICC pulses and return strokes) are characterized by very similar linear regression slopes, namely, 3.67 V/(m kA) for the ICC pulses and 3.77 V/(m kA) for the return strokes. Assuming the field-current relation based on the transmission line model, we estimated the apparent speed of both the RS-type ICC pulses and return strokes to be about 1.4 × 108 m/s. A strong linear correlation is observed between the E-field risetime and the current risetime for the ICC pulses, similar to the relation observed between the E-field risetime and current risetime for return strokes. The similarity of the RS-type ICC pulses with return strokes suggests that these pulses are associated with the mixed mode of charge transfer to ground.

  7. Development and testing of a 50 KA, pulsed superconducting cable

    Energy Technology Data Exchange (ETDEWEB)

    Wollan; DeClerc, J.; Hamilton, W.; Zeitlin, B.

    1983-05-01

    Prototype cables for 7.5 T, pulsed field application in tokamak poloidal field coils have been designed, fabricated, and evaluated. Successful fabrication of a 10 m superconducting sample represents the largest superconducting cable ever made. Details of the fabrication, the problems expected and encountered, and the solutions to those problems are discussed. Results of stability measurements on the superconducting prototype also are presented.

  8. High power semiconductor switches in the 12 kV, 50 kA pulse generator of the SPS beam dump kicker system

    CERN Document Server

    Bonthond, J; Faure, P; Vossenberg, Eugène B

    2001-01-01

    Horizontal deflection of the beam in the dump kicker system of the CERN SPS accelerator is obtained with a series of fast pulsed magnets. The high current pulses of 50 kA per magnet are generated with capacitor discharge type generators which, combined with a resistive free-wheel diode circuit, deliver a critically damped half-sine current with a rise-time of 25 ms. Each generator consists of two 25 kA units, connected in parallel to a magnet via a low inductance transmission line.

  9. FERROELECTRIC SWITCH FOR A HIGH-POWER Ka-BAND ACTIVE PULSE COMPRESSOR

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L. [Omega-P, Inc.

    2013-12-18

    Results are presented for design of a high-power microwave switch for operation at 34.3 GHz, intended for use in an active RF pulse compressor. The active element in the switch is a ring of ferroelectric material, whose dielectric constant can be rapidly changed by application of a high-voltage pulse. As envisioned, two of these switches would be built into a pair of delay lines, as in SLED-II at SLAC, so as to allow 30-MW μs-length Ka-band pulses to be compressed in time by a factor-of-9 and multiplied in amplitude to generate 200 MW peak power pulses. Such high-power pulses could be used for testing and evaluation of high-gradient mm-wave accelerator structures, for example. Evaluation of the switch design was carried out with an X-band (11.43 GHz) prototype, built to incorporate all the features required for the Ka-band version.

  10. Ferroelectric switch for a high-power Ka-band active pulse compressor

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT (United States)

    2013-12-18

    Results are presented for design of a high-power microwave switch for operation at 34.3 GHz, intended for use in an active RF pulse compressor. The active element in the switch is a ring of ferroelectric material, whose dielectric constant can be rapidly changed by application of a high-voltage pulse. As envisioned, two of these switches would be built into a pair of delay lines, as in SLED-II at SLAC, so as to allow 30-MW μs-length Ka-band pulses to be compressed in time by a factor-of-9 and multiplied in amplitude to generate 200 MW peak power pulses. Such high-power pulses could be used for testing and evaluation of high-gradient mm-wave accelerator structures, for example. Evaluation of the switch design was carried out with an X-band (11.43 GHz) prototype, built to incorporate all the features required for the Ka-band version.

  11. Preliminary results of a battery-based, multi megawatt 200 kA pulsed power supply.

    NARCIS (Netherlands)

    Karthaus, W.; Kolkert, W.J.; Nowee, J.

    1989-01-01

    A pulsed power supply consisting of a fast discharge battery, a switch based on silicon-controlled-rectifier SCR technology, and an energy storage/pulse transformer is discussed. Preliminary results indicate that the battery is capable of discharging current pulses with reproducible peak values of 6

  12. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.; Awasthi, L. M., E-mail: kushagra.lalit@gmail.com; Mattoo, S. K. [Institute for Plasma Research, Gandhinagar (India)

    2016-07-15

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  13. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    Science.gov (United States)

    Srivastava, P. K.; Singh, S. K.; Sanyasi, A. K.; Awasthi, L. M.; Mattoo, S. K.

    2016-07-01

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  14. High speed, high current pulsed driver circuit

    Energy Technology Data Exchange (ETDEWEB)

    Carlen, Christopher R.

    2017-03-21

    Various technologies presented herein relate to driving a LED such that the LED emits short duration pulses of light. This is accomplished by driving the LED with short duration, high amplitude current pulses. When the LED is driven by short duration, high amplitude current pulses, the LED emits light at a greater amplitude compared to when the LED is driven by continuous wave current.

  15. Soft switching (ZVZCS) high current, low voltage modular power converter (13 kA, 16 V)

    CERN Document Server

    Bordry, Frederick; Thiesen, H

    2001-01-01

    The Large Hadron Collider (LHC) is the next accelerator being constructed at the European Laboratory for Particle Physics (CERN). The superconducting LHC particle accelerator requires high currents (13 kA) and relatively low voltages (16 V) for its magnets. This paper describes the development and the production of a (13 kA, 16 V) power converter. The converter is made with a modular concept with five current sources (3.25 kA, 16 V) in parallel. The 3.25 kA sources are built as plug-in modules: a diode rectifier on the AC mains, a zero voltage zero current switching (ZVZCS) inverter working at 25 k Hz and an output stage. The obtained performance is presented and discussed. (6 refs).

  16. Development of the 320 kA pulsed magnetic horn power supply with a novel energy recovery system for the T2K experiment

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, Kunio, E-mail: kunio.koseki@kek.jp

    2014-01-21

    The 320 kA pulsed magnetic horn power supply with a novel magnetic energy recovery system for the T2K experiment has been developed. The magnetic energy once stored in the horn system during an excitation period by a pulsed current of 320 kA is recovered by a full-bridge circuit to the energy storage capacitors. Four switching arms by high-power thyristors in the full-bridge circuit are actively controlled for an efficient energy recovery process. Operational principle of the energy recovery system was proved by both the simulation study and the high-voltage test operation. Successful operations of the newly developed pulsed magnetic horn power supply were also confirmed by high-voltage test operations. -- Highlights: ●The 320 kA pulsed power supply for the T2K magnetic horn has been developed. ●A novel energy recovery method by a full-bridge circuit has been established. ●Successful operation of the pulsed power supply was confirmed by high-voltage operations.

  17. The 12 kV, 50 kA Pulse Generator for the SPS MKDH Horizontal Beam Dump Kicker System,equipped with Semiconductor Switches

    CERN Document Server

    Bonthond, J; Faure, P; Vossenberg, Eugène B; CERN. Geneva. SPS and LHC Division

    2001-01-01

    The high current pulses for the MKDH magnets are generated with capacitor discharge type generators which, combined with a resistive free-wheel diode circuit, deliver a critically damped half-sine current with a rise-time of 25 ms. Each generator consists of two 25 kA units, connected in parallel to a magnet via low inductance transmission lines. They are equipped with a stack of four Fast High Current Thyristors, together with snubber capacitors, a voltage divider and a specially designed trigger transformer.

  18. Pulse current enhanced electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian R.; Ottosen, Lisbeth M.; Jensen, Pernille E.

    2012-01-01

    Energy consumption is an important factor influencing the cost of electrodialytic soil remediation (EDR). It has been indicated that the pulse current (in low frequency range) could decrease the energy consumption during EDR. This work is focused on the comparison of energy saving effect...... at different pulse frequencies. Based on the restoration of equilibrium, the relaxation process of the soil-water system was investigated by chronopotentiometric analysis to find the optimal relaxation time for energy saving. Results showed that the pulse current decreased the energy consumption with different...... extent depending on the pulse frequency. The experiment with the frequency of 16 cycles per day showed the best restoration of equilibrium and lowest energy consumption. The energy consumption per removed heavy metals was lower in pulse current experiments than constant current and increased...

  19. Multichannel computerized control system of current pulses in LIU-30 electron accelerator

    CERN Document Server

    Gerasimov, A I; Kulgavchuk, V V; Pluzhnikov, A V

    2002-01-01

    In LIU-30 power linear pulsed induction electron accelerator (40 MeV, 10 kA, 25 ns) 288 radial lines with water insulation serve as energy accumulators and shapers of accelerating voltage pulses. The lines are charged simultaneously up to 500 kV using a system comprising 72 Arkadiev-Marx screened generators. To control parameter of synchronous pulses of charging current with up to 60 kA amplitude and 0.85 mu s duration in every of 72 charging circuits one applies a computer-aided system. Current pulse is recorded at output of every generator using the Rogowski coil signal from which via a cable line is transmitted to an analog-digital converter, is processed with 50 ns sampling and is recorded to a memory unit. Upon actuation of accelerator the signals are sequentially or selectively displayed and are compared with pulse typical shape

  20. Pulsed current cathodic protection of well casings

    Energy Technology Data Exchange (ETDEWEB)

    Bich, N.N. [Shell Canada Ltd., Fort Saskatchewan, Alberta (Canada). Scotford Complex; Bauman, J. [Shell Canada Ltd., Cochrane, Alberta (Canada). Jumping Pound Complex

    1995-04-01

    Electric pulses of several hundred volts, applied for very brief periods of time, several thousand times per second, are more effective and economical than conventional steady-state DC currents in protecting deep and/or close-spaced well casings against external corrosion. More uniform current distribution, greater depth of protection, reduced stray current interference, and small anode bed requirements are the main benefits of pulsed technology. Operating principles, equivalent electrical circuits, design considerations, and field cathodic protection logging experience is reviewed.

  1. Test results of the 18 kA EDIPO HTS current leads

    Energy Technology Data Exchange (ETDEWEB)

    Wesche, Rainer, E-mail: rainer.wesche@psi.ch [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland); Bagnasco, Maurizio; Bruzzone, Pierluigi; Felder, Roland; Guetg, Marc; Holenstein, Manuel; Jenni, Markus; March, Stephen; Roth, Felix; Vogel, Martin [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland)

    2011-10-15

    For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

  2. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  3. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  4. Design and Manufacture of 20 kA HTS Current Leads for a Hybrid Magnet System

    Science.gov (United States)

    Wesche, R.; Bruzzone, P.; March, S.; Vogel, M.; Ehmler, H.; Smeibidl, P.

    A new series connected 25 T hybrid magnet system is being developed by the Helmholtz Zentrum Berlin (HZB) for neutron scattering experiments. In collaboration with CRPP, high temperature superconducting (HTS) current leads have been developed for the powering of the outer superconducting coil. These HTS current leads, with a nominal current rating of 20 kA, have been designed and are being manufactured by CRPP, based on the design of the 18 kA EDIPO leads. Each of the two current leads consists of an HTS module cooled only by heat conduction from the cold end and a copper part actively cooled by helium gas of 44 K inlet temperature. To reach a temperature of 53.7 K at the warm end of the HTS a helium mass flow rate of 1.37 g/s per lead is required at a current of 20 kA. The estimated heat leak at the 4.5 K level caused only by heat conduction is as low as 1.4 W. The evolution of the temperatures in the case of a loss of flow has been calculated. In addition to the design, the main fabrication steps are described.

  5. Note: Design and tests of a 13 kA-6.5 kV thyristor switch for a pulsed inductive vacuum ultraviolet source.

    Science.gov (United States)

    Teske, C; Lee, B-J; Jacoby, J; Schweizer, W; Sun, J Chao

    2010-04-01

    In this paper, the design, construction, and test procedure of a closing switch prototype based on thyristors is described. In particular, details are given about the design criteria and about the triggering board architecture, which is a high side biased, self supplied unit using the electrical energy derived from a local snubber network for the gate drive. The structure guarantees a hard firing gate pulse for the required high dI/dt application. Further, the results of the prototype tests are presented and discussed. The stack assembly has a holding voltage of 6.5 kV and is used for switching a series resonant circuit with a ringing frequency of 12 kHz for a pulsed inductive vacuum ultraviolet source. Maximum current amplitudes of 13 kA and pulse energies of more than 600 J were switched during the test procedure.

  6. Ultra Fast Shutter Driven by Pulsed High Current

    Institute of Scientific and Technical Information of China (English)

    Zeng Jiangtao; Sun Fengju; Qiu Aici; Yin Jiahui; Guo Jianming; Chen Yulan

    2005-01-01

    Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90kA to140 kA and discharging current periods of approximately 13.1 μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities.

  7. Electrical and hydrodynamic characterization of a high current pulsed arc

    Science.gov (United States)

    Sousa Martins, R.; Chemartin, L.; Zaepffel, C.; Lalande, Ph; Soufiani, A.

    2016-05-01

    High current pulsed arcs are of significant industrial interest and, aiming to reduce time and cost, there is progressively more and more need for computation tools that describe and predict the behaviour of these arcs. These simulation codes need inputs and validations by experimental databases, but accurate data is missing for this category of electric discharges. The principal lack of understanding is with respect to the transient phase of the current, which can reach thousands of amperes in a few microseconds. In this paper, we present the work realized on an experimental setup that simulates in the laboratory an arc column subjected to five levels of high pulsed current, ranging from 10 kA to 100 kA, with the last one corresponding to the standard lightning current waveform used in aircraft certification processes. This device was instrumented by high speed video cameras to assess the characteristic sizes of the arc channel and to characterize the shock wave generated by the arc expansion. The arc channel radius was measured over time during the axisymmetric phase and reached 3.2 cm. The position and velocity of the shock wave was determined during the first 140 μs. The background-oriented schlieren method was used to study the shock wave and a model for the light deflection inside the shock wave was developed. The mass density profile of the shock wave was estimated and showed good agreement with Rankine-Hugoniot relations at the wave front. Electrical measurements were also used to estimate the time-dependent resistance and conductivity of the arc for times lasting up to 50 μs.

  8. Current pulse shaping of the load current on PTS

    Directory of Open Access Journals (Sweden)

    Minghe Xia

    2016-02-01

    Full Text Available The typical rise time of PTS machine is ∼110 ns with about 10 MA peak current under short pulse mode when all 24 modules discharge simultaneously. By distributing the trigger times of 12 laser beams logically and adjusting the statues of the pulse output switches, longer rise-time pulse can be obtained on the PTS facility. Based on the required pulse shape, whole circuit simulations will be used to calculate the trigger times of each laser triggering gas switch and the status of the pulse output switches. The rise time of the current is determined by the time difference between the first and last trigged laser triggering gas switches. In order to trigger the laser triggering gas switch, sufficient laser power is needed to be sent into the gap of the gas switches. The gas pressure and voltage difference on the two electrodes of the gas switches also affect the triggering of the gas switches, and the voltage added on the gas switch is determined by its transition time. Traditionally the trigger time difference should be less than the transition time of the two neighboring modules. A new simulation model of PTS shows one can break this transition time limits. Series of current pulse shaping experiments have been investigated on the PTS (Primary Test Stand. As results, more than 5 MA peak current were successfully achieved on the load with a rise time of 600 ns. This study and experiments of the pulse shaping on PTS demonstrate the adaptable ability of the PTS for offering different waveform of mega ampere current pulse for different research purpose.

  9. Pulsed current transformer for low inductive loads

    Science.gov (United States)

    Zielinski, Alex; Jamison, Keith; Bennett, John

    1987-10-01

    At the US Army Research, Development and Engineering Command (ARDEC), an effort was undertaken to couple an array of five capacitor banks to a low inductance load. To achieve currents which exceed the limit placed on the capacitor banks, pulse current transformers were used. This power system, termed CAPSTAR, was ultimately used to electromagnetically stress a round bore composite railgun barrel section. A mathematical model has been developed to simulate a capacitor power supply driving a pulse transformer with various secondary loads. The model was first tested by comparison to experimental results using a subscale pulse transformer. The calculated data points were in good agreement with the experiment. Minor adjustments to some circuit parameters to account for the transitory behavior of the circuit are described.

  10. Equivalent Resistance in Pulse Electric Current Sintering

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The sintering resistance for conductive TiB2 and non-conductive Al2O3 as well as empty die during pulse current sintering were investigated in this paper.Equivalent resistances were measured by current and valtage during sintering the conductive and non-conductive materials in the same conditions.It is found that the current paths for conductive are different from those for non-conductive materials.For non-conductive materials,sintering resistances are influenced by powder sizes and heating rates,which indicates that pulse current has some interaction with non-conductive powders.For conductive TiB2,sintering resistances are influenced by heating rates and ball-milling time,which indicates the effect of powders activated by spark.

  11. The anomalous currents in the front foils of the JET lost alpha diagnostic KA-2

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F. E. [Colorado School of Mines, Golden, Colorado 80401 (United States); Kiptily, V.; Salmi, A.; Horton, A.; Fullard, K. [Culham Science Center, Euratom/CCFE Fusion Association, Abingdon, Oxon (United Kingdom); Murari, A. [Consorzio RFX-Associazione EURATOM ENEA per la Fusione, I-35127 Padova (Italy); Darrow, D.; Hill, K. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Collaboration: JET-EFDA Contributors

    2010-10-15

    We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions (both deuterium and impurity) in the vicinity of the detector (including charge exchange neutrals) and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

  12. The Anomalous Currents In The Front Foils of the JET Lost Alpha Diagnostic KA-2

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F. E.; Kiptily, V.; Salmi, A.; Horton, A.; Fullard, K.; Murari, A.; Darrow, D.; Hill, K.

    2011-05-04

    We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions both deuterium and impurity in the vicinity of the detector including charge exchange neutrals and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

  13. A mechanical connector design for high-current, high-coulomb pulsed power systems

    Energy Technology Data Exchange (ETDEWEB)

    Susoeff, A.R.; Hawke, R.S.; Leighton, K.S.

    1992-02-25

    A technique to make reliable high-current, high-coulomb electrical contact was developed for transmitting power into railguns. The method uses spring loaded removable connectors that are installed independently from the launcher. The simple rod-type design and absence of fastener holes allow maximum utilization of material mechanical properties. Repeated experiments with 9.5-mm diameter connectors demonstrated reliable pulsed charge transfer of 200 coulombs at currents of over 400kA. 20 refs.

  14. Operational experience in the use of 18 kA HTS current leads for Edipo

    Science.gov (United States)

    March, S.; Wesche, R.; Bruzzone, P.

    2014-05-01

    In spring 2013, the Edipo facility of CRPP was commissioned. The dipole is powered via two 18 kA HTS current leads, designed and manufactured at CRPP. As part of the Edipo commissioning framework, the operational parameters of the leads were implemented in the control system. The in-situ tests were found to be in good agreement with the tests performed without a background field in 2011. The leads consist of a conduction cooled HTS module, made of AgMgAu/Bi-2223 stacks, and a wire bundle heat exchanger. The heat exchanger is cooled by forced flow helium gas, the inlet temperature of which was measured to vary between 65 K and 85 K. During operation with field, the mass flow rate is a function of current (2.05 g/s per lead at full field, 12.35 T, 17.2 kA). Reduced cooling investigations showed that 0.31 g/s per lead is suitable for overnight standby and 0.2 g/s per lead for longer periods. For detection of and protection against quench in the HTS module, a threshold of 10 mV was found to be appropriate. The heat exchanger has a voltage protection threshold of 120 mV. The temperatures of the heat exchanger, the HTS, and the helium inlet temperature were monitored in order to provide a further layer of protection.

  15. Neutron induced current pulses in fission chambers. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Taboas, A L; Buck, W L

    1978-01-01

    The mechanism of neutron induced current pulse generation in fission chambers is discussed. By application of the calculated detector transfer function to proposed detector current pulse shapes, and by comparison with actually observed detector output voltage pulses, a credible, semi-empirical, trapezoidal pulse shape of chamber current is obtained.

  16. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    Science.gov (United States)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-09-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  17. Measuring 20-100 T B-fields using Zeeman splitting of sodium emission lines on a 500 kA pulsed power machine

    Science.gov (United States)

    Banasek, J. T.; Engelbrecht, J. T.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A.

    2016-11-01

    We have shown that Zeeman splitting of the sodium (Na) D-lines at 5890 and 5896 Å can be used to measure the magnetic field (B-field) produced in high current pulsed power experiments. We have measured the B-field next to a return current conductor in a hybrid X-pinch experiment near a peak current of about 500 kA. Na is deposited on the conductor and then is desorbed and excited by radiation from the hybrid X-pinch. The D-line emission spectrum implies B-fields of about 20 T with a return current post of 4 mm diameter or up to 120 T with a return current wire of 0.455 mm diameter. These measurements were consistent or lower than the expected B-field, thereby showing that basic Zeeman splitting can be used to measure the B-field in a pulsed-power-driven high-energy-density (HED) plasma experiment. We hope to extend these measurement techniques using suitable ionized species to measurements within HED plasmas.

  18. Solid state Ka-band pulse oscillator with frequency electronic switching

    Directory of Open Access Journals (Sweden)

    Dvornichenko V. P.

    2015-08-01

    Full Text Available Transmitting devices for small radars in the millimeter wavelength range with high resolution on range and noise immunity. The work presents the results of research and development of compact pulse oscillators with digital frequency switching from pulse to pulse. The oscillator consists of a frequency synthesizer and a synchronized amplifier on the IMPATT diode. Reference oscillator of synthesizer is synchronized by crystal oscillator with digital PLL system and contains a frequency multiplier and an amplifier operating in pulse mode. Small-sized frequency synthesizer of 8 mm wave lengths provides an output power of ~1.2 W per pulse with a frequency stability of no worse than 2•10–6. Radiation frequency is controlled by three-digit binary code in OOL levels. Synchronized amplifier made on IMPATT diodes provides microwave power up to 20 W in oscillator output with microwave pulse duration of 100—300 ns in an operating band. The oscillator can be used as a driving source for the synchronization of semiconductor and electro-vacuum devices of pulsed mode, and also as a transmitting device for small-sized radar of millimeter wave range.

  19. Optimizing pulsed current micro plasma arc welding parameters to ...

    African Journals Online (AJOL)

    user

    Pulsed current MPAW involves cycling the welding current at selected regular frequency. ..... At high pulse, the vibration amplitude and temperature oscillation induced on .... received his Masters Degree from JNTU Hyderabad, India in 2002.

  20. Development and testing of a 50-kA, pulsed superconducting cable

    Science.gov (United States)

    Wollan, J. J.; Hamilton, W. C.; Declerc, J.; Zeitlin, B. A.

    1982-11-01

    Prototype cables for 7.5-T, pulsed field application in Tokamak poloidal coils were designed, fabricated, and evaluated. Successful fabrication of a 10 m superconducting sample represents the largest superconducting cable ever made. Details of the fabrication, the problems expected and encountered, and the solutions to those problems are discussed. Results of stability measurements on the superconducting prototype also are presented.

  1. Development and testing of a 50-kA, pulsed superconducting cable

    Energy Technology Data Exchange (ETDEWEB)

    Wollan, J.J.; Hamilton, W.C.; DeClerc, J.; Zeitlin, B.A.

    1982-01-01

    Prototype cables for 7.5-T, pulsed field application in tokamak poloidal field coils have been designed, fabricated, and evaluated. Successful fabrication of a 10 m superconducting sample represents the largest superconducting cable ever made. Details of the fabrication, the problems expected and encountered, and the solutions to those problems are discussed. Results of stability measurements on the superconducting prototype also are presented.

  2. a KA-BAND Chirped-Pulse Fourier Transform Microwave Spectrometer.

    Science.gov (United States)

    Zaleski, Daniel P.; Neill, Justin L.; Muckle, Matthew T.; Pate, Brooks H.; Carroll, P. Brandon; Weaver, Susanna L. Widicus

    2010-06-01

    The design and performance of a new chirped-pulse Fourier transform microwave (CP-FTMW) spectrometer operating from 25-40 GHz will be discussed. A 10.5-3 GHz linear frequency sweep, generated by a 24 GS/s arbitrary waveform generator, is upconverted by a 23.00 GHz phase-locked oscillator, then fed into an active doubler to create a 25-40 GHz chirped pulse. After amplification with a 60-80 W pulsed traveling wave tube amplifier, the pulse is broadcast across a molecular beam chamber where it interacts with a molecular sample. The molecular FID signal is downconverted with the 23 GHz oscillator so that it can be digitized on a 50 GS/s oscilloscope with 16 GHz hardware bandwidth. The sensitivity and phase stability of this spectrometer is comparable to that of the previously reported 6.5-18.5 CP-FTMW spectrometer. On propyne (μ=0.78 D), a single-shot signal to noise ratio of approximately 200:1 is observed on the J=2-1 rotational transition at 34183 MHz when the full bandwidth is swept; optimal excitation is observed for this transition with a 250 MHz bandwidth sweep. The emission has a T_2 lifetime of 4 μs. Early results from this spectrometer, particularly in the study of species of astrochemical interest, will be presented. G.G. Brown et al., Rev. Sci. Instrum. 79 (2008) 053103.

  3. Thermodynamic Optimisation of 70 kA Binary Current Lead (Final Report)

    Energy Technology Data Exchange (ETDEWEB)

    Wesche, R

    2002-02-01

    The thermal behaviour of binary 70 kA HTS current leads has been simulated numerically. The optimum temperature of the helium and the conductor at the cold end of the heat exchanger have been found to depend on the assumed refrigerator efficiency, the engineering critical current density of the AgAu/Bi-2223 tapes at the envisaged temperature at the warm end of the superconductor and the cross-section of the stainless steel support. Reduced engineering critical current densities as well as enlarged stainless steel cross-sections lead to a larger heat load at 4.5 K. As a consequence, the optimum temperature at the warm end of the HTS is shifted in both cases to lower values. When the efficiency of the intermediate temperature cooling cycle providing helium gas of the temperature T{sub i}n is enhanced with respect to the efficiency of the 4.5 K cooling cycle the optimum temperature at the warm end of the HTS is shifted to lower values. Considering ideal cooling cycles the optimum intermediate conductor temperature (warm end of HTS, cold end of heat exchanger) is between 75 and 80 K for a stainless steel cross-section of 40 cm{sup 2} and a total length of 1360 mm (HTS and heat exchanger without connections). The optimum difference of the conductor and the helium temperature at the cold end of the heat exchanger is approximately 20 K. However, even for a conductor temperature of 65 K and a helium inlet temperature of 45 K the required refrigerator input power needed to cool the current lead is only slightly enhanced. In the case of real cooling cycles the optimum intermediate conductor temperature is between 70 and 80 K for a stainless steel cross-section of 40 cm{sup 2} and a total length of 1360 mm. The . optimum difference of the conductor and helium temperature at the cold end of the heat exchanger is approximately 15 K. The safety requirements in the case of loss of flow favour a design with small values of j{sub op}/j{sub e}, a low temperature and an enhanced

  4. Design optimization of 600 A-13 kA current leads for the Large Hadron Collider project at CERN

    CERN Document Server

    Spiller, D M; Al-Mosawl, M K; Friend, C M; Thacker, P; Ballarino, A

    2001-01-01

    The requirements of the Large Hadron Collider project at CERN for high-temperature superconducting (HTS) current leads have been widely publicized. CERN require hybrid current leads of resistive and HTS materials with current ratings of 600 A, 6 kA and 13 kA. BICC General Superconductors, in collaboration with the University of Southampton, have developed and manufactured prototype current leads for the Large Hadron Collider project. The resistive section consists of a phosphorus de-oxidized copper conductor and heat exchanger and the HTS section is constructed from BICC General's (Pb, Bi)2223 tapes with a reduced thermal conductivity Ag alloy sheath. We present the results of the materials optimization studies for the resistive and the HTS sections. Some results of the acceptance tests at CERN are discussed. (9 refs).

  5. Improvements on Pulsed Current Sharing in Driving Parallel MOSFETs

    Science.gov (United States)

    Takagi, Hajime; Orihara, Masato; Yamada, Tsutomu; Yanagidaira, Takeshi

    To switch high-voltage and high-current pulses by using MOS (Metal Oxide Semiconductor) transistors, it is necessary to distribute evenly the voltage and current to each element connected in series and parallel. In parallel connection, the current flowing in each element is different depending on the series resistance and wiring inductance. We verified improvements on pulsed current sharing in parallel transistors which were arranged in line on a printed circuit board. Although Gate and Drain wirings are different in length, pulsed current was evenly distributed by using transmission line transformers. Dissipation in transistors were equalized and four transistors were driven simultaneously near the rated current.

  6. Detailed characteristics of intermittent current pulses due to positive corona

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang, E-mail: liuyangwuh520@sina.com; Cui, Xiang; Lu, Tiebing; Wang, Zhenguo; Li, Xuebao; Xiang, Yu; Wang, Xiaobo [State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206 (China)

    2014-08-15

    In order to get detailed characteristics of intermittent current pulses due to positive corona such as the repetition rate of burst-pulse trains, the peak value ratio of the primary pulse to the secondary pulse, the number of pulses per burst, and the interval of the secondary pulses, a systematic study was carried out in a coaxial conductor-cylinder electrode system with the conductor electrode being set with a discharge point. Empirical formulae for the number of pulses per burst and the interval of the secondary pulses are first presented. A theoretical model based on the motion of the space-charge clouds is proposed. Analysis with the model gives explanations to the experimental results and reveals some new insights into the physical mechanism of positive intermittent corona.

  7. Reducing the beam current in Linac4 in pulse to pulse mode.

    CERN Document Server

    Lallement, JB; CERN. Geneva. BE Department

    2009-01-01

    In order to deliver different beam intensities to users, we studied the possibility of varying the Linac4 beam current at PS Booster injection in pulse to pulse mode. This report gives the possible configurations of Linac4 Low and Medium Energy Beam Transport lines (LEBT and MEBT) that lead to a consistent current reduction.

  8. Cathodic protection of well casings by pulsed current

    Energy Technology Data Exchange (ETDEWEB)

    Bich, N.N. [Shell Canada Ltd., Fort Saskatchewan, Alberta (Canada). Scotford Complex; Bauman, J. [Shell Canada Ltd., Cochrane, Alberta (Canada). Jumping Pound Complex

    1994-12-31

    Electric pulses of several hundred volts, applied for very brief periods of time, several thousand times per second, are more effective and economical than conventional DC currents in protecting deep and/or close spaced well casings against external corrosion. More uniform current distribution, greater depth of protection, reduced stray current interference, and smaller anode bed requirements are the main benefits of pulsed technology. Operating principles, equivalent electrical circuits, design considerations and field cathodic protection logging experience will be reviewed.

  9. <3> OMEGA pulse-forming network

    CERN Multimedia

    1974-01-01

    Adjustement of the 3 W pulse-forming network of the SPS beam dumping system. When charged at 60 kV, this PFN gives 10 kA, 25 ms current pulses, with oscillations, superimposed on the pulse flat top, of an amplitude of +/- 1 Ka.

  10. Electrodialytic soil remediation enhanced by low frequency pulse current

    DEFF Research Database (Denmark)

    Mortensen, John; Sun, Tian Ran; Ottosen, Lisbeth M.

    2013-01-01

    The effect of low frequency pulse current on decreasing the polarization and energy consumption during the process of electrodialytic soil remediation was investigated in the present work. The results indicated that the transportation of cations through the cation exchange membrane was the rate...... current experiment compared to the constant current experiment. At the cation exchange membrane, only the resistance caused by concentration polarization decreased. In the soil compartment, an average of +60 mV overpotential caused by the polarization of the electric double layer of the clay particles...... controlling step both in constant and pulse current experiments, thus responsible for the major energy consumption. After 180 h, a decrease in both the initial ohmic resistance in each pulse cycle and the resistance caused by concentration polarization of the anion exchange membrane were seen in the pulse...

  11. High ion charge states in a high-current, short-pulse, vacuum ARC ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Anders, A.; Brown, I.; MacGill, R.; Dickinson, M. [Lawrence Berkeley National Lab., CA (United States)

    1996-08-01

    Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1-4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several {mu}s) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution.

  12. Electron beam dynamics in the long-pulse, high-current DARHT-II linear induction accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A [Los Alamos National Laboratory; Abeyta, Epifanio O [Los Alamos National Laboratory; Aragon, Paul [Los Alamos National Laboratory; Archuleta, Rita [Los Alamos National Laboratory; Cook, Gerald [Los Alamos National Laboratory; Dalmas, Dale [Los Alamos National Laboratory; Esquibel, Kevin [Los Alamos National Laboratory; Gallegos, Robert A [Los Alamos National Laboratory; Garnett, Robert [Los Alamos National Laboratory; Harrison, James F [Los Alamos National Laboratory; Johnson, Jeffrey B [Los Alamos National Laboratory; Jacquez, Edward B [Los Alamos National Laboratory; Mccuistian, Brian T [Los Alamos National Laboratory; Montoya, Nicholas A [Los Alamos National Laboratory; Nath, Subrato [Los Alamos National Laboratory; Nielsen, Kurt [Los Alamos National Laboratory; Oro, David [Los Alamos National Laboratory; Prichard, Benjamin [Los Alamos National Laboratory; Rowton, Lawrence [Los Alamos National Laboratory; Sanchez, Manolito [Los Alamos National Laboratory; Scarpetti, Raymond [Los Alamos National Laboratory; Schauer, Martin M [Los Alamos National Laboratory; Seitz, Gerald [Los Alamos National Laboratory; Schulze, Martin [Los Alamos National Laboratory; Bender, Howard A [Los Alamos National Laboratory; Broste, William B [Los Alamos National Laboratory; Carlson, Carl A [Los Alamos National Laboratory; Frayer, Daniel K [Los Alamos National Laboratory; Johnson, Douglas E [Los Alamos National Laboratory; Tom, C Y [Los Alamos National Laboratory; Williams, John [Los Alamos National Laboratory; Hughes, Thomas [Los Alamos National Laboratory; Anaya, Richard [LLNL; Caporaso, George [LLNL; Chambers, Frank [LLNL; Chen, Yu - Jiuan [LLNL; Falabella, Steve [LLNL; Guethlein, Gary [LLNL; Raymond, Brett [LLNL; Richardson, Roger [LLNL; Trainham, C [NSTEC/STL; Watson, Jim [LLNL; Weir, John [LLNL; Genoni, Thomas [VOSS; Toma, Carsten [VOSS

    2009-01-01

    The DARHT-II linear induction accelerator (LIA) now accelerates 2-kA electron beams to more than 17 MeV. This LIA is unique in that the accelerated current pulse width is greater than 2 microseconds. This pulse has a flat-top region where the final electron kinetic energy varies by less than 1% for more than 1.5 microseconds. The long risetime of the 6-cell injector current pulse is 0.5 {micro}s, which can be scraped off in a beam-head cleanup zone before entering the 68-cell main accelerator. We discuss our experience with tuning this novel accelerator; and present data for the resulting beam transport and dynamics. We also present beam stability data, and relate these to previous stability experiments at lower current and energy.

  13. Characterization of a high current pulsed arc using optical emission spectroscopy

    Science.gov (United States)

    Sousa Martins, R.; Zaepffel, C.; Chemartin, L.; Lalande, Ph; Soufiani, A.

    2016-10-01

    In this paper, we present the investigation realized on an experimental setup that simulates an arc column subjected to the transient phase of a lightning current waveform in laboratory conditions. Optical emission spectroscopy is employed to assess space- and time-resolved properties of this high current pulsed arc. Different current peak levels are utilised in this work, ranging from 10 kA to 100 kA, with a peak time around 15 µs. Ionic lines of nitrogen and oxygen are used to determine the radial profiles of temperature and electron density of the arc channel over time from 2 µs to 36 µs. A combination of 192 N II and O II lines is considered in the calculation of the bound-bound contribution of the absorption coefficient of the plasma channel. Calculations of the optical thickness showed that self-absorption of these ionic lines in the arc column is important. To obtain temperature and electron density profiles in the arc, we solved the radiative transfer equation across the channel under an axisymmetric assumption and considering the channel formed by uniform concentric layers. For the 100 kA current peak level, the temperature reaches more than 38 000 K and the electron density reaches 5  ×  1018 cm-3. The pressure inside the channel is calculated using the air plasma composition at local thermodynamic equilibrium, and reaches 45 bar. The results are discussed and utilised to estimate the electrical conductivity of the arc channel.

  14. Wavelength stabilisation during current pulsing of tapered laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin

    2009-01-01

    The use of external feedback to stabilise the frequency of a tapered laser during current pulsing is reported. Using this technique more than 20 W of peak power in 60 ns pulses from the tapered laser is obtained and owing to the external feedback, the laser is tunable in the 778-808 nm range....... The spectral width of the tapered laser is significantly narrowed compared to the freely running laser....

  15. Contribution For Arc Temperature Affected By Current Increment Ratio At Peak Current In Pulsed Arc

    Science.gov (United States)

    Kano, Ryota; Mitubori, Hironori; Iwao, Toru

    2015-11-01

    Tungsten Inert Gas (TIG) Welding is one of the high quality welding. However, parameters of the pulsed arc welding are many and complicated. if the welding parameters are not appropriate, the welding pool shape becomes wide and shallow.the convection of driving force contributes to the welding pool shape. However, in the case of changing current waveform as the pulse high frequency TIG welding, the arc temperature does not follow the change of the current. Other result of the calculation, in particular, the arc temperature at the reaching time of peak current is based on these considerations. Thus, the accurate measurement of the temperature at the time is required. Therefore, the objective of this research is the elucidation of contribution for arc temperature affected by current increment ratio at peak current in pulsed arc. It should obtain a detail knowledge of the welding model in pulsed arc. The temperature in the case of increment of the peak current from the base current is measured by using spectroscopy. As a result, when the arc current increases from 100 A to 150 A at 120 ms, the transient response of the temperature didn't occur during increasing current. Thus, during the current rise, it has been verified by measuring. Therefore, the contribution for arc temperature affected by current increment ratio at peak current in pulsed arc was elucidated in order to obtain more knowledge of welding model of pulsed arc.

  16. Design, Assembly, and Commissioning of a Cryogenic DC Current Transformer Designed for Measuring Currents of up to 80 kA

    CERN Document Server

    Montenero, G; Bottura, L; Arpaia, P

    2015-01-01

    A new cryogenic dc current transformer (Cryo-DCCT) has recently been designed and assembled at CERN. The device, whose design is based on that of a high-accuracy 600 A market solution suitable for room temperature applications, is optimized for measuring currents of up to 80 kA and for operation at 4.2 K. The CryoDCCT has been conceived with the objective of preserving the metrological performance of the original commercial device in the new extended range of operation. For reducing the effect of interfering magnetic fields arising from test conditions, it incorporates ferromagnetic and MgB2 superconducting shields. In this paper, the design of the CryoDCCT and the results of the commissioning of the device at CERN are reported. The effectiveness of the current transducer is analysed and discussed. This new device will be used for measuring the secondary current of a 80 kA superconducting transformer feeding a sample of NbSn3 cable at the Facility for Research on Superconducting Cables (FRESCA) at CERN.

  17. Electric breakdown during the pulsed current spreading in the sand

    Energy Technology Data Exchange (ETDEWEB)

    Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru; Vetchinin, S. P.; Panov, V. A.; Pecherkin, V. Ya.; Son, E. E. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-03-15

    Processes of spreading of the pulsed current from spherical electrodes and an electric breakdown in the quartz sand are studied experimentally. When the current density on the electrode exceeds the critical value, a nonlinear reduction occurs in the grounding resistance as a result of sparking in the soil. The critical electric field strengths for ionization and breakdown are determined. The ionization-overheating instability is shown to develop on the electrode, which leads to the current contraction and formation of plasma channels.

  18. Pulse current gas metal arc welding characteristics, control and applications

    CERN Document Server

    Ghosh, Prakriti Kumar

    2017-01-01

    This monograph is a first-of-its-kind compilation on high deposition pulse current GMAW process. The nine chapters of this monograph may serve as a comprehensive knowledge tool to use advanced welding engineering in prospective applications. The contents of this book will prove useful to the shop floor welding engineer in handling this otherwise critical welding process with confidence. It will also serve to inspire researchers to think critically on more versatile applications of the unique nature of pulse current in GMAW process to develop cutting edge welding technology.

  19. Series Production of 13 kA Current Leads with Dry and Compact Warm Terminals

    CERN Document Server

    Andersen, T P; Vullierme, B

    2005-01-01

    For the LHC magnet test benches 13 pairs of conventional helium vapour-cooled 13 kA current leads are required. The current leads have been designed and built by industry. Attention was given to economical and reliable design and to a design of the warm terminal in order to avoid any condensation. Three pairs of them were tested at CERN. The dry warm terminal enables voltage test at 4.1 kV at cold condition. The paper describes construction details and compares calculated and measured values of the main parameters.

  20. High speed transfer switch with 50 kA and 50 kV ratings

    Science.gov (United States)

    Reass, W. A.; Kasik, R. J.; Wilds, W. A.

    This paper gives the mechanical design and electrical parameters of a pneumatically operated transfer switch. This design is used to switch 3-second 50-kA current pulses, and is easily capable of 75 kA operation, with water-cooled versions capable of 20 kA continuously. Although the switch is not specifically designed to make or break 50 kA, it is provided with auxiliary Elkonite arcing contacts that have proven their value in protecting the main electrodes even under repetitive (50 kA) fault conditions. Included in this presentation will be the results of extensive life testing and associated criteria.

  1. Plasma heating and current drive using intense, pulsed microwaves

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B.I.; Cohen, R.H.; Nevins, W.M.; Rognlien, T.D.; Bonoli, P.T.; Porkolab, M.

    1988-01-01

    The use of powerful new microwave sources, e.g., free-electron lasers and relativistic gyrotrons, provide unique opportunities for novel heating and current-drive schemes in the electron-cyclotron and lower-hybrid ranges of frequencies. These high-power, pulsed sources have a number of technical advantages over conventional, low-intensity sources; and their use can lead to improved current-drive efficiencies and better penetration into a reactor-grade plasma in specific cases. The Microwave Tokamak Experiment at Lawrence Livermore National Laboratory will provide a test for some of these new heating and current-drive schemes. This paper reports theoretical progress both in modeling absorption and current drive for intense pulses and in analyzing some of the possible complications that may arise, e.g., parametric instabilities and nonlinear self-focusing. 22 refs., 9 figs., 1 tab.

  2. Oceanic Density Fronts Steering Bottom-Current Induced Sedimentation Deduced from a 50 ka Contourite-Drift Record and Numerical Modeling (off NW Spain)

    Science.gov (United States)

    Hanebuth, T. J. J.; Zhang, W.; Hofmann, A. L.; Lowemark, L. A.; Schwenk, T.

    2015-12-01

    How bottom-near hydrographic and sedimentary processes control the formation of bottom-current related confined deep-sea depocenters remains widely speculative. The geological approach of this study uses a transect of sediment cores and sediment echosounder profiles across a whole contourite system off NW Spain. This "mounded patch"-type contourite drift (18 km long, 20 km wide) with a 150-m deep moat has formed around an 800-m high structural obstacle. Past deposition was characterized by alternating calm and high-energy bottom-flow conditions. Calm conditions (Last Glacial period: 27-17 cal ka BP; late Holocene times: current-influenced deposition of fine-grained sediments (10 µm) over the entire basin. In contrast, waxing-and-waning high-energy conditions (D/O events during Marine Isotope Stage 3; the Deglacial/early Holocene time interval at 17-4 cal ka BP) resulted in coarse grained (70 µm) deposition. Process-based numerical modelling demonstrates that pulse-like oceanic density fronts travelling within the transition zone of two water masses (Labrador Sea Water, Mediterranean Outflow Water) provide a powerful mechanism for contouritic deposition, rather than the core of a water mass itself. These gravity-driven density fronts lead to local re-suspension of sand from the moat and to subsequent upward transport over the crest. Here, the oceanic density fronts produce additional km-scale eddies. These migrating eddies provide an efficient mechanism for further widespread sediment re-distribution. In comparison with paleoceanographic reconstructions, a downward migration or expansion of the Mediterranean Outflow Water by about 300 m led most probably to such temporary contouritic sand deposition. We finally propose a conceptual model to explain how seafloor obstacles redirect and perturbate bottom currents. This model proposes water mass transition zone as an important high-energy medium, for oceanic density fronts to travel. On the respective time scale, the

  3. Eddy current pulsed phase thermography and feature extraction

    Science.gov (United States)

    He, Yunze; Tian, GuiYun; Pan, Mengchun; Chen, Dixiang

    2013-08-01

    This letter proposed an eddy current pulsed phase thermography technique combing eddy current excitation, infrared imaging, and phase analysis. One steel sample is selected as the material under test to avoid the influence of skin depth, which provides subsurface defects with different depths. The experimental results show that this proposed method can eliminate non-uniform heating and improve defect detectability. Several features are extracted from differential phase spectra and the preliminary linear relationships are built to measure these subsurface defects' depth.

  4. ARRAY PULSED EDDY CURRENT IMAGING SYSTEM USED TO DETECT CORROSION

    Institute of Scientific and Technical Information of China (English)

    Yang Binfeng; Luo Feilu; Cao Xiongheng; Xu Xiaojie

    2005-01-01

    A theory model is established to describe the voltage-current response function. The peak amplitude and the zero-crossing time of the transient signal is extracted as the imaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The test results show that this system has the advantage of fast scanning speed, different imaging mode and quantitative detection, it has a broad application in the aviation nondestructive testing.

  5. Design and characterization of the annular cathode high current pulsed electron beam source for circular components

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Wang, Langping, E-mail: aplpwang@hit.edu.cn; Wang, Xiaofeng

    2016-08-01

    Highlights: • An annular cathode for HCPEB irradiation of circular components was designed. • The processing window for the annular cathode is obtained. • Irradiation thickness uniformity along the circumferential direction exceeds 90%. - Abstract: In order to irradiate circular components with high current pulsed electron beam (HCPEB), an annular cathode based on carbon fiber bunches was designed and fabricated. Using an acceleration voltage of 25 kV, the maximum pulsed irradiation current and energy of this annular cathode can reach 7.9 kA and 300 J, respectively. The irradiation current density distribution of the annular cathode HCPEB source measured along the circumferential direction shows that the annular cathode has good emission uniformity. In addition, four 9310 steel substrates fixed uniformly along the circumferential direction of a metal ring substrate were irradiated by this annular cathode HCPEB source. The surface and cross-section morphologies of the irradiated samples were characterized by scanning electron microscopy (SEM). SEM images of the surface reveal that crater and surface undulation have been formed, which hints that the irradiation energy of the HCPEB process is large enough for surface modification of 9310 steel. Meanwhile, SEM cross-section images exhibit that remelted layers with a thickness of about 5.4 μm have been obtained in all samples, which proves that a good practical irradiation uniformity can be achieved by this annular cathode HCPEB source.

  6. A high current, high gradient, laser excited, pulsed electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Batchelor, K.; Farrell, J.P.; Dudnikova, G. [Brookhaven Technology Group, Inc., Stony Brook, NY (United States); Ben-Zvi, I.; Srinivasan-Rao, T.; Smedley, J.; Yakimenko, V. [Brookhaven National Lab., Upton, NY (United States)

    1998-06-01

    This paper describes a pulsed electron gun that can be used as an FEL, as an injector for electron linear accelerators or for rf power generation. It comprises a 1 to 5 MeV, 1 to 2 ns pulsed power supply feeding a single diode, photoexcited acceleration gap. Beam quality of a {approximately}1nC charge in {approximately}1 GV/m field was studied. Computations of the beam parameters as a function of electrode configuration and peak electron current are presented together with descriptions of the power supply, laser and beam diagnostics systems.

  7. Physics and Dynamics of Current Sheets in Pulsed Plasma Thrusters

    Science.gov (United States)

    2007-11-02

    pulsed plasma thruster. A simple experiment would involve measuring the impulse bit of a coaxial gas-fed pulsed plasma thruster operated in both positive...Princeton, NJ, 2002. [2] J. Marshal. Performance of a hydromagnetic plasma gun . The Physics of Fluids, 3(1):134–135, January-February 1960. [3] R.G. Jahn...Jahn and K.E. Clark. A large dielecteic vacuum facility. AIAA Jour- nal, 1966. [16] L.C. Burkhardt and R.H. Lovberg. Current sheet in a coaxial plasma

  8. Eddy current pulsed thermography for fatigue evaluation of gear

    Science.gov (United States)

    Tian, Gui Yun; Yin, Aijun; Gao, Bin; Zhang, Jishan; Shaw, Brian

    2014-02-01

    The pulsed eddy current (PEC) technique generates responses over a wide range of frequencies, containing more spectral coverage than traditional eddy current inspection. Eddy current pulsed thermography (ECPT), a newly developed non-destructive testing (NDT) technique, has advantages such as rapid inspection of a large area within a short time, high spatial resolution, high sensitivity and stand-off measurement distance. This paper investigates ECPT for the evaluation of gear fatigue tests. The paper proposes a statistical method based on single channel blind source separation to extract details of gear fatigue. The discussion of transient thermal distribution and patterns of fatigue contact surfaces as well as the non-contact surfaces have been reported. In addition, the measurement for gears with different cycles of fatigue tests by ECPTand the comparison results between ECPT with magnetic Barkhausen noise (MBN) have been evaluated. The comparison shows the competitive capability of ECPT in fatigue evaluation.

  9. Pulsed Current Gas Metal Arc Welding under Different Shielding and Pulse Parameters; Part 2: Behaviour of Metal Transfer

    National Research Council Canada - National Science Library

    Ghosh, P. K; Dorn, Lutz; Devakumaran, K; Hofmann, F

    2009-01-01

    ...) of pulsed current gas metal arc welding (P-GMAW) using mild steel filler wire have been studied with respect to change in pulse parameters under different gas shieldings of Ar+2%CO2 and Ar+18%CO2...

  10. Transport critical current of MgB2 wires: pulsed current of varying rate compared to direct current method

    Science.gov (United States)

    See, K. W.; Xu, X.; Horvat, J.; Cook, C. D.; Dou, S. X.

    2011-10-01

    The measurement of transport critical current (Ic) for MgB2 wires and tapes has been investigated with two different techniques, the conventional four-probe arrangement with direct current (DC) power source, and a tailored triangle pulse at different rates of current change. The DC method has been widely used and practiced by various groups, but suffers from inevitable heating effects when high currents are used at low magnetic fields. The pulsed current method has no heating effects, but the critical current can depend on the rate of the current change (dI/dt) in the pulse. Our pulsed current measurements with varying dI/dt show that the same values of Ic are obtained as with the DC method, but without the artifacts of heating. Our method is particularly useful at low field regions which are often inaccessible by DC methods. We also performed a finite element method (FEM) analysis to obtain the time dependent heat distribution in MgB2 due to the electric potential produced at the current contacts to the superconducting sample and its gradient around the contacts. This gradient is defined as the current transfer length (CTL) of the samples and leads to Joule heating of the wire near the contacts. The FEM results provide further evidence of the limitation of the DC method in obtaining high transport critical current.

  11. Investigation on a new inducer of pulsed eddy current thermography

    Science.gov (United States)

    He, Min; Zhang, Laibin; Zheng, Wenpei; Feng, Yijing

    2016-09-01

    In this paper, a new inducer of pulsed eddy current thermography (PECT) is presented. The use of the inducer can help avoid the problem of blocking the infrared (IR) camera's view in eddy current thermography technique. The inducer can also provide even heating of the test specimen. This paper is concerned with the temperature distribution law around the crack on a specimen when utilizing the new inducer. Firstly, relative mathematical models are provided. In the following section, eddy current distribution and temperature distribution around the crack are studied using the numerical simulation method. The best separation distance between the inducer and the specimen is also determined. Then, results of temperature distribution around the crack stimulated by the inducer are gained by experiments. Effect of current value on temperature rise is studied as well in the experiments. Based on temperature data, temperature features of the crack are discussed.

  12. Investigation on a new inducer of pulsed eddy current thermography

    Directory of Open Access Journals (Sweden)

    Min He

    2016-09-01

    Full Text Available In this paper, a new inducer of pulsed eddy current thermography (PECT is presented. The use of the inducer can help avoid the problem of blocking the infrared (IR camera’s view in eddy current thermography technique. The inducer can also provide even heating of the test specimen. This paper is concerned with the temperature distribution law around the crack on a specimen when utilizing the new inducer. Firstly, relative mathematical models are provided. In the following section, eddy current distribution and temperature distribution around the crack are studied using the numerical simulation method. The best separation distance between the inducer and the specimen is also determined. Then, results of temperature distribution around the crack stimulated by the inducer are gained by experiments. Effect of current value on temperature rise is studied as well in the experiments. Based on temperature data, temperature features of the crack are discussed.

  13. Optimizing the Pulsed Current Gas Tungsten Arc Welding Parameters

    Institute of Scientific and Technical Information of China (English)

    M. Balasubramanian; V. Jayabalan; V. Balasubramanian

    2006-01-01

    The selection of process parameter in the gas tungsten arc (GTA) welding of titanium alloy was presented for obtaining optimum grain size and hardness. Titanium alloy (Ti-6Al-4V) is one of the most important non-ferrous metals which offers great potential application in aerospace, biomedical and chemical industries,because of its low density (4.5 g/cm3), excellent corrosion resistance, high strength, attractive fracture behaviour and high melting point (1678℃). The preferred welding process for titanium alloy is frequent GTA welding due to its comparatively easier applicability and better economy. In the case of single pass (GTA)welding of thinner section of this alloy, the pulsed current has been found beneficial due to its advantages over the conventional continuous current process. Many considerations come into the picture and one needs to carefully balance various pulse current parameters to reach an optimum combination. Four factors, five level, central composite, rotatable design matrix were used to optimize the required number of experimental conditions. Mathematical models were developed to predict the fusion zone grain size using analysis of variance (ANOVA) and regression analysis. The developed models were optimized using the traditional Hooke and Jeeve's algorithm. Experimental results were provided to illustrate the proposed approach.

  14. Eddy current pulsed phase thermography for subsurface defect quantitatively evaluation

    Science.gov (United States)

    He, Yunze; Pan, Mengchun; Tian, GuiYun; Chen, Dixiang; Tang, Ying; Zhang, Hong

    2013-09-01

    This Letter verified eddy current pulse phase thermography through numerical and experimental studies. During the numerical studies, two characteristic features, blind frequency and min phase, were extracted from differential phase spectra, and their monotonic relationships with defects' depth under different heating time were compared. According to the numerical studies, 100 ms was employed as heating time during the improved experimental studies. The experimental results agreed with the numerical results. Based on their linear relationship with defects' depths, both features can be used to measure the defect's depth.

  15. Thickness Evaluation of Aluminium Plate Using Pulsed Eddy Current Technique

    Science.gov (United States)

    Singh, Gurpartap; Bapat, Harsh Madhukar; Singh, Bhanu Pratap; Bandyopadhyay, Manojit; Puri, Rakesh Kumar; Badodkar, Deepak Narayanrao

    2013-10-01

    This paper describes a pulsed eddy current (PEC) based non-destructive testing system used for detection of thickness variation in aluminium plate. A giant magneto-resistive sensor has been used instead of pick up coil for detecting resultant magnetic field. The PEC response signals obtained from 1 to 5 mm thickness change in aluminium plate were investigated. Two time domain features, namely peak value and time to peak, of PEC response were used for extracting information about thickness variation in aluminium plate. The variation of peak value and time to peak with thickness was compared. A program was developed to display the thickness variation of the tested sample.

  16. Influence of pulse line switch inductance on output characteristics of high-current nanosecond accelerators

    Science.gov (United States)

    Mashchenko, A. I.; Vintizenko, I. I.

    2016-06-01

    Various types of high-current nanosecond accelerators are simulated numerically using an equivalent circuit representation. The influence of pulse forming line switch inductance on the amplitude and waveform of output voltage and current pulses is analyzed.

  17. Direct Current and Pulsed Direct Current Plasma Nitriding of Ferrous Materials a Critical Review

    Directory of Open Access Journals (Sweden)

    Łępicka Magdalena

    2016-06-01

    Full Text Available Nowadays, the improvement of ferrous materials performance is a problem of high interest. One of well-known wear- and corrosion properties improving technique is plasma nitriding, in which elemental nitrogen is introduced to the surface of a metal part for subsequent diffusion into the material. As a result, a compound, “white” layer and a diffusion zone are formed at the detail’s surface. Most of the authors positively describe the effects of surface ion nitiding. On the other hand, there are also reports on adverse effects of direct current and pulsed direct current plasma nitriding on ferrous materials performance. Therefore, an attempt to provide comprehensive summary on direct current and pulsed direct current ion nitriding and its influence on ferrous materials’ mechanical and corrosion properties has been made. According to the results, some of the technique drawbacks are hard to avoid in mass production.

  18. Current status of Dual Ka-band radar field campaign in Japan for GPM/DPR mission

    Science.gov (United States)

    Kaneko, Yuki; Nakagawa, Katsuhiro; Nishikawa, Masanori; Nakamura, Kenji; Fujiyoshi, Yasushi; Hanado, Hiroshi; Minda, Haruya; Yamamoto, Kazuhide; Oki, Riko; Furukawa, Kinji

    2013-04-01

    The Global Precipitation Measurement (GPM) mission is an expanded follow-on mission to TRMM (Tropical Rainfall Measuring Mission) and a GPM core satellite will carry dual frequency precipitation radar (DPR) and a GPM Microwave Imager on board. The DPR, which is being developed by National Institute of Information and Communications Technology (NICT) and Japan Aerospace Exploration Agency (JAXA), consists of two radars; Ku-band precipitation radar (KuPR) and Ka-band radar (KaPR). The DPR is expected to advance precipitation science by expanding the coverage of observations to higher latitudes than those of the TRMM/PR, measuring snow and light rain by the KaPR, and providing drop size distribution information based on the differential attenuation of echoes at two frequencies. In order to secure the quality of precipitation estimates, ground validation (GV) of satellite data and retrieval algorithms is essential. Since end-to-end comparisons between instantaneous precipitation data observed by satellite and ground-based instruments is not enough to improve the algorithms. The error of various physical parameters in the precipitation retrieval algorithms (e.g. attenuation factor, drop size distribution, terminal velocity, density of the snow particles, etc.) will be estimated by the comparison with the ground-based observation data. A dual Ka-band radar system is developed by the JAXA for the GPM/DPR algorithm development. The dual Ka-radar system which consists of two identical Ka-band radars can measure both the specific attenuation and the equivalent radar reflectivity at Ka-band. Those parameters are important particularly for snow measurement. Using the dual Ka-radar system along with other instruments, such as a polarimetric precipitation radar, a wind-profiler radar, ground-based precipitation measurement systems, the uncertainties of the parameters in the DPR algorithm can be reduced. The verification of improvement of rain retrieval with the DPR algorithm is

  19. Interfacing transformer for a pulsed load current exceeding 1 MA

    CERN Document Server

    Cliffe, R J; Brown, J

    2003-01-01

    In much pulsed power experimentation a capacitor bank is discharged into an inductive load, but although sufficient energy may be available in the capacitors their voltage rating may considerably exceed that necessary for the load and the current delivered during the experiment may accordingly be too low. This paper describes a novel design of air-cored transformer that has been used as an interfacing or matching device in such a situation, where peak load currents between 1 and 2 MA were required. Design considerations led to the use of an air-cored autotransformer connection wound with copper sheet conductors. Although thick wide conductors and clamping are needed to prevent deformation due to high magnetic pressure, the transformer is nevertheless relatively simple, easy to make, lightweight and inexpensive. This paper describes the design and the winding arrangement of the transformer that was constructed, and presents typical experimental results.

  20. Current mode pulse width modulation/pulse position modulation based on phase lock loop

    Science.gov (United States)

    Wisartpong, Pichet; Silaphan, Vorapong; Kurutach, Sunee; Wardkein, Paramote

    2017-05-01

    In this paper, the fully integrated CMOS current mode PLL with current input injects at the place of input or output of the loop filter without summing amplifier circuit. It functions as PPM and PWM circuit is present. In addition, its frequency response is an analysis which electronic tuning BPF and LPF are obtained. The proposed circuit has been designed with 0.18 μm CMOS technology. The simulation results of this circuit can be operated at 2.5 V supply voltage, at center frequency 100 MHz. The linear range of input current can be adjusted from 43 μA to 109 μA, and the corresponding duty cycle of pulse width output is from 93% to 16% and the normalized pulse position is from 0.93 to 0.16. The power dissipation of this circuit is 4.68 mW with the total chip area is 28 μm × 60 μm.

  1. Conceptual design of a 20-kA current lead using forced-flow cooling and Ag-alloy-sheathed Bi-2223 high-temperature superconductors

    Science.gov (United States)

    Heller, Reinhard; Hull, John R.

    High-temperature superconductors (HTS's), consisting of Bi-2223 HTS tapes sheathed with Ag alloys are proposed for a 20-kA current lead for the planned stellarator WENDELSTEIN 7-X. Forced-flow He cooling is used, and 4-K He cooling of the whole lead as well as 60-K He cooling of the copper part of the lead, is discussed. Power consumption and behavior in case of loss of He flow are given.

  2. Physical interpretation and separation of eddy current pulsed thermography

    Science.gov (United States)

    Yin, Aijun; Gao, Bin; Yun Tian, Gui; Woo, W. L.; Li, Kongjing

    2013-02-01

    Eddy current pulsed thermography (ECPT) applies induction heating and a thermal camera for non-destructive testing and evaluation (NDT&E). Because of the variation in resultant surface heat distribution, the physical mechanism that corresponds to the general behavior of ECPT can be divided into an accumulation of Joule heating via eddy current and heat diffusion. However, throughout the literature, the heating mechanisms of ECPT are not given in detail in the above two thermal phenomena and they are difficult to be separated. Nevertheless, once these two physical parameters are separated, they can be directly used to detect anomalies and predict the variation in material properties such as electrical conductivity, magnetic permeability and microstructure. This paper reports physical interpretation of these two physical phenomena that can be found in different time responses given the ECPT image sequences. Based on the phenomenon and their behaviors, the paper proposes a statistical method based on single channel blind source separation to decompose the two physical phenomena using different stages of eddy current and thermal propagation from the ECPT images. Links between mathematical models and physical models have been discussed and verified. This fundamental understanding of transient eddy current distribution and heating propagation can be applied to the development of feature extraction and pattern recognition for the quantitative analysis of ECPT measurement images and defect characterization.

  3. History and current status of commercial pulsed laser deposition equipment

    Science.gov (United States)

    Greer, James A.

    2014-01-01

    This paper will review the history of the scale-up of the pulsed laser deposition (PLD) process from small areas ∼1 cm2 up to 10 m2 starting in about 1987. It also documents the history of commercialization of PLD as various companies become involved in selling fully integrated laser deposition tools starting in 1989. The paper will highlight the current state of the art of commercial PLD equipment for R&D that is available on the market today from mainstream vendors as well as production-oriented applications directed at piezo-electric materials for microelectromechanical systems and high-temperature superconductors for coated-conductor applications. The paper clearly demonstrates that considerable improvements have been made to scaling this unique physical vapour deposition process to useful substrate sizes, and that commercial deposition equipment is readily available from a variety of vendors to address a wide variety of technologically important thin-film applications.

  4. Development of high current beam ns pulsed system

    CERN Document Server

    Shen Guan Ren; Gao Fu; Guan Xia Ling; LiuNaiYi

    2001-01-01

    The development of high current beam ns pulsed system of CPNG and its characteristic, main technological performance and application are introduced. Firstly, important parameters of the system are calculated using theoretical model, the design requirements of some important parts are understood. Some mistakes in physics conception are corrected. Second, the chopper is designed for parallel plate deflector, chopping aperture and sine wave voltage sweeping device. It is emphasized that the conception of parallel plate load impedance is the capacitance load, but not the 50 ohm load impedance. The dynamic capacitance value has been measured. The output emphasizes the output voltage amplitude, but not the output power for sweeping device. The display system of output sweeping voltage was set up and it is sure that the maximum output voltage(V-V) is >=4000 V. The klystron buncher are re-designed. It is emphasized to overcome difficulty of support high voltage electrode in the klystron and insulator of input sine wa...

  5. Repair of nonunions by electrically pulsed current stimulation.

    Science.gov (United States)

    Zichner, L

    1981-01-01

    Five congenital and 52 acquired nonunions of bone were stimulated using an invasive device. The unit delivered a constant but pulsed right-angled current of positive polarity measuring 20 to 25 muAmps (voltage of 750 mV) and a frequency of 20 Hz. The power pack encapsulated in epoxy resin was implanted at the time of operative fragment stabilization. THe cathode was inserted at the site of the nonunion gap. After two to 12 months, all but two of the acquired nonunions and one of the congenital pseudarthroses healed. In the unsuccessful cases, the bone ends were often totally necrotic. Four cases required reimplantation because of broken wires or expiration of the battery, and two cases failed owing to purulent infection. Electrostimulation is an adjuvant treatment to fragment stabilization in hyporeactive and hypovascular or congenital pseudarthroses. Electrical stimuli may be assumed to simulate conditions which are essential for bone healing.

  6. Defect Automatic Identification of Eddy Current Pulsed Thermography

    Directory of Open Access Journals (Sweden)

    Kai Chen

    2014-01-01

    Full Text Available Eddy current pulsed thermography (ECPT is an effective nondestructive testing and evaluation (NDT&E technique, and has been applied for a wide range of conductive materials. Manual selected frames have been used for defects detection and quantification. Defects are indicated by high/low temperature in the frames. However, the variation of surface emissivity sometimes introduces illusory temperature inhomogeneity and results in false alarm. To improve the probability of detection, this paper proposes a two-heat balance states-based method which can restrain the influence of the emissivity. In addition, the independent component analysis (ICA is also applied to automatically identify defect patterns and quantify the defects. An experiment was carried out to validate the proposed methods.

  7. High-speed pulse train amplification in semiconductor optical amplifiers with optimized bias current.

    Science.gov (United States)

    Xia, Mingjun; Ghafouri-Shiraz, H; Hou, Lianping; Kelly, Anthony E

    2017-02-01

    In this paper, we have experimentally investigated the optimized bias current of semiconductor optical amplifiers (SOAs) to achieve high-speed input pulse train amplification with high gain and low distortion. Variations of the amplified output pulse duration with the amplifier bias currents have been analyzed and, compared to the input pulse duration, the amplified output pulse duration is broadened. As the SOA bias current decreases from the high level (larger than the saturated bias current) to the low level, the broadened pulse duration of the amplified output pulse initially decreases slowly and then rapidly. Based on the analysis, an optimized bias current of SOA for high-speed pulse train amplification is introduced. The relation between the SOA optimized bias current and the parameters of the input pulse train (pulse duration, power, and repetition rate) are experimentally studied. It is found that the larger the input pulse duration, the lower the input pulse power or a higher repetition rate can lead to a larger SOA optimized bias current, which corresponds to a larger optimized SOA gain. The effects of assist light injection and different amplifier temperatures on the SOA optimized bias current are studied and it is found that assist light injection can effectively increase the SOA optimized bias current while SOA has a lower optimized bias current at the temperature 20°C than that at other temperatures.

  8. Effect of Rectangle Wave Pulse Current on Solidification Structure of ZA27 Alloy

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The effect of rectangle wave pulse current on solidification structure of ZA27 alloy was studied.The results show that the wave pattern relies on the frequency range of harmonic wave and the energy of pulse current within the frequency range of pulse current.Imposed pulse current could induce the solidification system to oscillate.The frequency range and the relevant energy distribution of pulse current exert an influence on the amount of atoms involved for forming critical nucleus, the surface states of clusters in melt, the oscillating state of melt on the surface of clusters, the active energy of atom diffusion , the frequnce response of the resonance of bulk melt and the absorbability of the solidification system to the external work.Rectangle wave pulse current involves rich harmonic waves; the amplitudes of high order of harmonic waves are higher and reduce slowly, so it has a better effect on inoculation and modification.

  9. Inverse problem of pulsed eddy current field of ferromagnetic plates

    Science.gov (United States)

    Chen, Xing-Le; Lei, Yin-Zhao

    2015-03-01

    To determine the wall thickness, conductivity and permeability of a ferromagnetic plate, an inverse problem is established with measured values and calculated values of time-domain induced voltage in pulsed eddy current testing on the plate. From time-domain analytical expressions of the partial derivatives of induced voltage with respect to parameters, it is deduced that the partial derivatives are approximately linearly dependent. Then the constraints of these parameters are obtained by solving a partial linear differential equation. It is indicated that only the product of conductivity and wall thickness, and the product of relative permeability and wall thickness can be determined accurately through the inverse problem with time-domain induced voltage. In the practical testing, supposing the conductivity of the ferromagnetic plate under test is a fixed value, and then the relative variation of wall thickness between two testing points can be calculated via the ratio of the corresponding inversion results of the product of conductivity and wall thickness. Finally, this method for wall thickness measurement is verified by the experiment results of a carbon steel plate. Project supported by the National Defense Basic Technology Research Program of China (Grant No. Z132013T001).

  10. Investigation of casing inspection through tubing with pulsed eddy current

    Science.gov (United States)

    Fu, Yuewen; Yu, Runqiao; Peng, Xuewen; Ren, Shangkun

    2012-12-01

    Corrosion and cracks of casing string in oil wells is a serious problem on which little research has been done when inspecting casing through tubing. In this study, inspecting casing through tubing with pulsed eddy current is investigated. Longitudinal and transverse probes are centred inside the tubing to detect wall thinnings and cracks in casing. A time slice of induced voltage in the receiving coil of the probe is used as the feature to recognise defects. The experimental results show that large area wall thinnings and long cracks in casing are detected successfully through the tubing with appropriate inspection parameters. The probe's orientation to the crack is important and a particular discovery is that the transverse probe should be parallel to the transverse crack and not be perpendicular to it when inspecting. A method based on linear regression is proposed to estimate flaws in casing while wall thinning in the tubing occurs at the same location. The method is effective for large area thinning in casing when tubing thinning is wide.

  11. A high current, short pulse electron source for wakefield accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Ching-Hung

    1992-12-31

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed.

  12. A high current, short pulse electron source for wakefield accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Ching-Hung.

    1992-01-01

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed.

  13. WORKING FEATURES OF POWER SOURCE SYSTEMS – A MULTIPLE CURRENT PULSE GENERATOR

    Directory of Open Access Journals (Sweden)

    Shs.V. Argun

    2013-04-01

    Full Text Available An analysis of circuit designs as to connecting a magnetic pulse action tool to a power source has been carried out. Design features of a magnetic pulse installation control and monitoring system in a multiple current pulse mode have been revealed. The description of the control and monitoring system block diagrams has been presented.

  14. The study of Zn–Co alloy coatings electrochemically deposited by pulse current

    Directory of Open Access Journals (Sweden)

    Tomić Milorad V.

    2012-01-01

    Full Text Available The electrochemical deposition by pulse current of Zn-Co alloy coatings on steel was examined, with the aim to find out whether pulse plating could produce alloys that could offer a better corrosion protection. The influence of on-time and the average current density on the cathodic current efficiency, coating morphology, surface roughness and corrosion stability in 3% NaCl was examined. At the same Ton/Toff ratio the current efficiency was insignificantly smaller for deposition at higher average current density. It was shown that, depending on the on-time, pulse plating could produce more homogenous alloy coatings with finer morphology, as compared to deposits obtained by direct current. The surface roughness was the greatest for Zn-Co alloy coatings deposited with direct current, as compared with alloy coatings deposited with pulse current, for both examined average current densities. It was also shown that Zn-Co alloy coatings deposited by pulse current could increase the corrosion stability of Zn-Co alloy coatings on steel. Namely, alloy coatings deposited with pulse current showed higher corrosion stability, as compared with alloy coatings deposited with direct current, for almost all examined cathodic times, Ton. Alloy coatings deposited at higher average current density showed greater corrosion stability as compared with coatings deposited by pulse current at smaller average current density. It was shown that deposits obtained with pulse current and cathodic time of 10 ms had the poorest corrosion stability, for both investigated average deposition current density. Among all investigated alloy coatings the highest corrosion stability was obtained for Zn-Co alloy coatings deposited with pulsed current at higher average current density (jav = 4 A dm-2.

  15. Pulsed eddy current inspection of CF-188 inner wing spar

    Science.gov (United States)

    Horan, Peter Francis

    Royal Canadian Air Force (RCAF) CF-188 Hornet aircraft engineering authorities have stated a requirement for a Non-Destructive Evaluation (NDE) technique to detect Stress Corrosion Cracking (SCC) in the inner wing spars without fastener or composite wing skin removal. Current radiographic inspections involve significant aircraft downtime, and Pulsed Eddy Current (PEC) inspection is proposed as a solution. The aluminum inner wing spars of CF-188 Hornet aircraft may undergo stress corrosion cracking (SCC) along the spar between the fasteners that secure carbon-fiber/ epoxy composite skin to the wing. Inspection of the spar through the wing skin is required to avoid wing disassembly. The thickness of the wing skin varies between 8 and 20 mm (0.3 to 0.8 inch) and fasteners may be either titanium or ferrous. PEC generated by a probe centered over a fastener, demonstrates capability of detecting simulated cracks within spars with the wing skin present. Comparison of signals from separate sensors, mounted to either side of the excitation coil, is used to detect differences in induced eddy current fields, which arise in the presence of cracks. To overcome variability in PEC signal response due to variation in 1) skin thickness, 2) fastener material and size, and 3) centering over fasteners, a large calibration data set is acquired. Multi-dimensional scores from a Modified Principal Components Analysis (PCA) of the data are reduced to one dimension (1D) using a Discriminant Analysis method. Under inspection conditions, calibrated PCA scores combined with discriminant analysis permit rapid real time go/no-go PEC detection of cracks in CF-188 inner wing spar. Probe designs using both pickup coils and Giant Magnetoresistive (GMR) sensors were tested on samples with the same ferrous and titanium fasteners found on the CF-188. Flaws were correctly detected at lift-offs of up to 21mm utilizing a variety of insulating skin materials simulating the carbon-fibre reinforced polymer

  16. Self-pulsing in a low-current hollow cathode discharge: From Townsend to glow discharge

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Yu [School of Physics, Beijing Institute of Technology, Beijing 100081 (China); School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081 (China); Xie, Kan, E-mail: xiekan@bit.edu.cn [School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081 (China); Zhang, Yu; Ouyang, Jiting [School of Physics, Beijing Institute of Technology, Beijing 100081 (China)

    2016-02-15

    We investigate the self-pulsing phenomenon of a low current cavity discharge in a cylindrical hollow cathode in pure argon. The waveforms of pulsed current and voltage are measured, and the time-averaged and time-resolved images of hollow cathode discharge are recorded by using high-speed intensified charge coupled device camera. The results show that the self-pulsing is a mode transition between low-current stage of Townsend discharge and high-current stage of glow discharge. During the self-pulsing, the current rising time relates to the dissipation of space charges, and the decay time relates to the reconstruction of the virtual anode by the accumulation of positive ions. Whether or not space charges can form and keep the virtual anode is responsible for the discharge mode and hence plays an important role in the self-pulsing phenomenon in low current hollow cathode discharge.

  17. Effects of Pulse Current on Solidification Structure of Austenitic Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    FAN Jin-hui; CHEN Yu; LI Ren-xing; ZHAI Qi-jie

    2004-01-01

    The 1Cr18Ni9Ti specimens were treated respectively with pulse current under 520 V and 2 600 V during solidification and the solidification structure was observed. The results showed that pulse current can refine solidification grains, cut primary dentrities remarkably and reduce second dentritic arm spacing. The mechanism and effect are changed with operation parameters.

  18. Influence of the skin effect and current risetime on the fragmentation of wires by pulsed currents

    Science.gov (United States)

    Wall, D. P.; Allen, J. E.; Molokov, S.

    2005-07-01

    This study considers the physical phenomenon whereby wires may fragment in the solid state when subject to a sufficiently high pulsed electric current. A mathematical model is constructed within continuum mechanics which considers both Lorentz force and thermal mechanisms for the creation of stress waves in a wire. Previous studies are extended by including the skin effect, that is allowing for the diffusion of current density across the wire, and also investigating the influence of current risetime. Axisymmetric solutions are sought for rigid-lubricated, clamped, and free wire ends. Analytical solutions are obtained for the case of rigid-lubricated wire ends, while for the other cases the governing equations are solved numerically using an application-specific explicit finite-difference scheme, which is staggered in time and space. The inclusion of the skin effect leads to significant qualitative and quantitative differences in results. For example, in some cases we find tension in the longitudinal (τzz) stress component, which experiments suggest to be responsible for the fragmentation process, while the uniform-current model predicts compression. In most cases, the inclusion of the skin effect leads to higher peak tensile τzz stresses. Some understanding of the present results is gained with reference to analytical quasistatic solutions. Stresses generated by the Lorentz force mechanism are found to be more sensitive than those generated by the thermal mechanism to the current risetime. In both cases axial stresses increase with decreasing current risetime. Despite the differences in the results obtained with the inclusion of the skin effect, our results support the broad conclusions of the uniform-current model results; the largest stresses are found at the clamps for a wire with clamped ends, while the largest stresses in a wire with free ends are generated by the thermal mechanism and are located at the center of the wire.

  19. Microstructural refinement of weld fusion zones in {alpha}-{beta} titanium alloys using pulsed current welding

    Energy Technology Data Exchange (ETDEWEB)

    Sundaresan, S.; Janaki Ram, G.D. [Indian Inst. of Technol., Chennai (India). Dept. of Metallurgical Engineering; Madhusudhan Reddy, G. [Defence Metallurgical Research Lab., Hyderabad (India)

    1999-04-01

    Pulsing of the welding current is one approach for refining the fusion zone grain structure in {alpha}-{beta} titanium alloy welds. This paper reports work in which gas tungsten-arc welds were produced in two {alpha}-{beta} titanium alloys under a variety of conditions including direct current (d.c.) pulsing and alternating current (a.c.) pulsing. The results show that, while d.c. pulsing did also refine the weld metal {beta} grain structure, the effect of a.c. pulsing was much greater. Current pulsing enhances fluid flow, reduces temperature gradients and causes a continual change in the weld pool size and shape. These effects, which are believed to be responsible for refining the solidification structure, are much stronger in a.c. pulsing than in d.c. pulsing. The observed grain refinement was shown to result in an appreciable increase in fusion zone tensile ductility. Post-weld heat treatment improved ductility both in pulsed and unpulsed welds, but pulsed welds showed greater tensile elongation even in the heat treated condition. (orig.) 27 refs.

  20. The NC Power Supply Design of Large Current and Wide Frequency Pulse in SEAM

    Directory of Open Access Journals (Sweden)

    Jianping Zhou

    2013-07-01

    Full Text Available There are a lot of ways to achieve large current pulse power supply, and the more common way is to adopt the inverter switching circuit to achieve pulse power supply. The core of the NC power supply design of large current and wide frequency pulse in SEAM is using two-stage modulation. Combined with inverter technology, DC chopper technology and NC technology, it not only can achieve the adjustability of the output pulse amplitude, but also can realize continuous adjustment of the output pulses and the duty cycle. The front stage of power supply uses DC/DC transformation circuit with the UC3879 integrated control chip as the core. With the microcontroller as the control core, the backward stage uses DC chopper circuit to achieve the NC power supply of multi-parameter adjustable output large current pulse.

  1. Alternating Pulse Current in Electrocoagulation for Wastewater Treatment to Prevent the Passivation or Al Electrode

    Institute of Scientific and Technical Information of China (English)

    MAO Xuhui; HONG Song; ZHU Hua; LIN Hui; WEI Lin; GAN Fuxing

    2008-01-01

    A novel current feed style, alternating pulse current, was proposed in electrocoagulation aiming at preventing the passivation of electrode materials. The open circuit potential (OCP) measurements after anodic and cathodic potentiodynamic polarization showed that cathodic polarization could activate Al electrode. The surface of Al electrode after alternating pulse current electrocoagulation was investigated by scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS), and the results indicate that passivation of Al is not observed. Furthermore, the simulated wastewater treatment tests show that alternating pulse current electrocoagulation has a visible energy saving effect and is worthy of generalization.

  2. Fast and efficient STT switching in MTJ using additional transient pulse current

    Science.gov (United States)

    Pathak, Sachin; Cha, Jongin; Jo, Kangwook; Yoon, Hongil; Hong, Jongill

    2017-06-01

    We propose a profile of write pulse current-density to switch magnetization in a perpendicular magnetic tunnel junction to reduce switching time and write energy as well. Our simulated results show that an overshoot transient pulse current-density (current spike) imposed to conventional rectangular-shaped pulse current-density (main pulse) significantly improves switching speed that yields the reduction in write energy accordingly. For example, we could dramatically reduce the switching time by 80% and thereby reduce the write energy over 9% in comparison to the switching without current spike. The current spike affects the spin dynamics of the free layer and reduces the switching time mainly due to spin torque induced. On the other hand, the large Oersted field induced causes changes in spin texture. We believe our proposed write scheme can make a breakthrough in magnetic random access memory technology seeking both high speed operation and low energy consumption.

  3. Influence of the Thomson effect on the pulse heating of high-current electrical contacts

    Science.gov (United States)

    Merkushev, A. G.; Pavleino, M. A.; Pavleino, O. M.; Pavlov, V. A.

    2014-09-01

    Pulse heating of high-current contacts is notable for the presence of considerable temperature gradients in the contact area, which cause the Thomson effect—the appearance of thermoelectric currents. The amount of this effect against conventional Joule heat release is quantitatively estimated. Pulse heating of electrical contacts is numerically simulated with the use of the Comsol program package. It is demonstrated that thermoelectric currents make a negligible contribution to heating in the case of copper contacts.

  4. Pulsed Excitation in Eddy Current Non-Destructive Testing of Conductive Materials

    Directory of Open Access Journals (Sweden)

    Ladislav Janousek

    2008-01-01

    Full Text Available The paper deals with eddy current non-destructive testing of conductive materials. Basic principle of the method is explained. Two types of eddy current excitation, the harmonic one and the pulsed one, are discussed. The characteristics, advantages as well as disadvantages of the two excitation methods are compared. It is explained that the pulsed excitation gives more complex information about a tested object. Experimental results of the pulsed eddy current testing of a defect in an Aluminium plate are presented

  5. Low-noise pulsed current source for magnetic-field measurements of magnets for accelerators

    Science.gov (United States)

    Omelyanenko, M. M.; Borisov, V. V.; Donyagin, A. M.; Khodzhibagiyan, H. G.; Kostromin, S. A.; Makarov, A. A.; Shemchuk, A. V.

    2017-01-01

    The schematic diagram, design, and technical characteristics of the pulsed current source developed and produced for the magnetic-field measurement system of superconducting magnets for accelerators are described. The current source is based on the current regulator with pass transistor bank in the linear mode. Output current pulses (0-100 A) are produced by utilizing the energy of the preliminarily charged capacitor bank (5-40 V), which is additionally charged between pulses. The output current does not have the mains frequency and harmonics ripple. The relative noise level is less than-100 dB (or 10-5) of RMS value (it is defined as the ratio of output RMS noise current to a maximal output current of 100 A within the operating bandwidth, expressed in dB). The work was performed at the Veksler and Baldin Laboratory of High Energy Physics, Joint Institute for Nuclear Research (JINR).

  6. The effect of pulse current on energy saving during Electrochemical Chloride Extraction (ECE) in concrete

    DEFF Research Database (Denmark)

    Sun, Tian R.; Geiker, Mette R.; Ottosen, Lisbeth M.

    2012-01-01

    Energy consumption is a factor influencing the cost of Electrochemical Chloride Extraction (ECE) in concrete. The aims of this work were to investigate the possibility for energy saving when using a pulsed electric field during ECE and the effect of the pulsed current on removal of chloride. Four...... experiments with artificially polluted concrete under same charge transfer were conducted. Results showed that the energy consumption was decreased 15% by pulse current in experiments with 0.2 mA/cm2 current density, which was higher than that of 0.1 mA/cm2 experiments with a decrease of 9.6%. When comparing...... the voltage drop at different parts of the experimental cells, it was found that the voltage drop of the area across the concrete was the major contributor to energy consumption, and results indicated that the pulse current could decrease the voltage drop of this part by re-distribution of ions in pore fluid...

  7. Aging characteristics of blue InGaN micro-light emitting diodes at an extremely high current density of 3.5 kA cm-2

    Science.gov (United States)

    Tian, Pengfei; Althumali, Ahmad; Gu, Erdan; Watson, Ian M.; Dawson, Martin D.; Liu, Ran

    2016-04-01

    The aging characteristics of blue InGaN micro-light emitting diodes (micro-LEDs) with different sizes have been studied at an extremely high current density 3.5 kA cm-2 for emerging micro-LED applications including visible light communication (VLC), micro-LED pumped organic lasers and optogenetics. The light output power of micro-LEDs first increases and then decreases due to the competition of Mg activation in p-GaN layer and defect generation in the active region. The smaller micro-LEDs show less light output power degradation compared with larger micro-LEDs, which is attributed to the lower junction temperature of smaller micro-LEDs. It is found that the high current density without additional junction temperature cannot induce significant micro-LED degradation at room temperature but the combination of the high current density and high junction temperature leads to strong degradation. Furthermore, the cluster LEDs, composed of a micro-LED array, have been developed with both high light output power and less light output degradation for micro-LED applications in solid state lighting and VLC.

  8. Eddy-current inspection of ferromagnetic tubing using pulsed magnetic saturation

    Energy Technology Data Exchange (ETDEWEB)

    Dodd, C V; Deeds, W E

    1986-07-01

    A pulsed eddy-current system has been designed and developed for nondestructive evaluation of 2.25Cr-1Mo steam generator tubing from the bore side. Since the tubing is ferromagnetic, a large current pulse is sent through a driver coil to produce magnetic saturation all the way through the tube wall. A pickup coil produces an output pulse that is dependent upon the tube properties as well as the driving pulse. The output pulse heights at selected times are used as data that are computer-correlated with calibration data taken from machined standards. Performance data, circuit diagrams, and computer programs are given for the system, which has been demonstrated to detect small flaws located near the outside of a thick ferromagnetic tube.

  9. Empirical compensation function for eddy current effects in pulsed field gradient nuclear magnetic resonance experiments.

    Science.gov (United States)

    Zhu, X X; Macdonald, P M

    1995-05-01

    An empirical compensation function for the correction of eddy current effects in the Stejskal-Tanner pulsed-gradient spin-echo (PGSE) nuclear magnetic resonance (NMR) experiments has been established. Eddy currents may arise as a result of the application of sharp and strong gradient pulses and may cause severe distortion of the NMR signals. In this method, the length of one gradient pulse is altered to compensate for the eddy current effects. The compensation is considered to be ideal when the position and the phase of the spin-echo maximum obtained from an aqueous solution of poly(ethylene glycol) (PEG) is the same in the presence and absence of a gradient pulse in the PGSE pulse sequence. We first characterized the functional dependence of the length of the required compensation on the three principal variables in the PGSE experiment: the gradient strength, the duration of the gradient pulse, and the interval between the two gradient pulses. Subsequently, we derived a model which successfully describes the general relationship between these variables and the size of the induced eddy current. The parameters extracted from fitting the model to the experimental compensation data may be used to predict the correct compensation for any combination of the three principal variables.

  10. Sensitivity of carbon paleoproductivity in the Southern California Current System on different time scales for the last 2 ka

    Science.gov (United States)

    Abella-Gutiérrez, Jose; Herguera, Juan Carlos

    2016-07-01

    The San Lázaro Basin (SLB) sediment record is highly sensitive to the El Niño-Southern Oscillation (ENSO) and the Pacific Decadal Oscillation (PDO) due to its location vertically underlying the dynamic boundary between the northern, cooler and fresher waters of the California Current System (CCS) and the southern, warmer and saltier surface waters from the subtropics and tropics. Warm sea surface temperatures (SSTs) and the ensuing stratified surface water column favor carbonate productivity, mostly dominated by the export of coccolithophorids as observed during El Niño events, while cool SSTs and a less stratified water column favor a relatively higher export of organic carbon. Here we show how during the last two millennia, the mechanisms that drive the organic carbon and carbonate export depend on the time scale considered. The organic carbon and carbonate records show opposite trends for the past 2000 years. On multicentennial periodicities, their variability is probably a result of precessional forcing and associated decreasing Northern Hemisphere insolation, which has been shown to affect the migration of the Intertropical Convergence Zone and the polar jet stream. On shorter time scales, interannual to centennial, the SLB records exhibit an ENSO-like variability; similarly, decadal to multidecadal variability is correlated with instrumental and reconstructed PDO records. We further show how interannual variance seems to have increased during the Little Ice Age, most likely related to large ENSO events, in contrast with an apparent reduction in this type of variability between 400 and 1350 Common Era, suggesting a changing sensitivity of the ENSO teleconnection in the southern CCS for the past two millennia.

  11. Effect of melt pulse electric current and thermal treatment on A356 alloy

    Institute of Scientific and Technical Information of China (English)

    何树先; 王俊; 江莞; 孙宝德; 周尧和

    2003-01-01

    Effects of the melt pulse electric current and thermal treatment on solidification structures of A356 alloywere investigated. In the experiments, the low temperature melt(953 K and 903 K) treated by pulse electric currentwas mixed with high temperature melt(1 223 K). By the control experiments, the results show that the solidificationstructure of A356 alloy is refined apparently by the pulse electric current togeth er with melt thermal treatmentprocess, and the mechanical properties, especially the elongation ratio of the specimen treated is improved greatly.The structure change of the melt by pulse electric current and melt thermal treatment is the main reason for the re-finement of the solidification structure of A356 alloy.

  12. Versatile Stimulation Back-End With Programmable Exponential Current Pulse Shapes for a Retinal Visual Prosthesis.

    Science.gov (United States)

    Maghami, Mohammad Hossein; Sodagar, Amir M; Sawan, Mohamad

    2016-11-01

    This paper reports on the design, implementation, and test of a stimulation back-end, for an implantable retinal prosthesis. In addition to traditional rectangular pulse shapes, the circuit features biphasic stimulation pulses with both rising and falling exponential shapes, whose time constants are digitally programmable. A class-B second generation current conveyor is used as a wide-swing, high-output-resistance stimulation current driver, delivering stimulation current pulses of up to ±96 μA to the target tissue. Duration of the generated current pulses is programmable within the range of 100 μs to 3 ms. Current-mode digital-to-analog converters (DACs) are used to program the amplitudes of the stimulation pulses. Fabricated using the IBM 130 nm process, the circuit consumes 1.5×1.5 mm(2) of silicon area. According to the measurements, the DACs exhibit DNL and INL of 0.23 LSB and 0.364 LSB, respectively. Experimental results indicate that the stimuli generator meets expected requirements when connected to electrode-tissue impedance of as high as 25 k Ω. Maximum power consumption of the proposed design is 3.4 mW when delivering biphasic rectangular pulses to the target load. A charge pump block is in charge of the upconversion of the standard 1.2-V supply voltage to ±3.3V.

  13. Present and Future of Semiconductor Pulsed Power Generator ˜Role of Power Semiconductor Devices in Plasma Research˜ 6.High-Speed, Large-Current Power Semiconductors for Pulse Power Generation

    Science.gov (United States)

    Takata, Ikunori

    This paper describes the operation principles and limits of power semiconductors. In addition, operation mechanisms of the new pulse power devices, SOS (Semiconductor Opening Switch) and dynistors, are explained qualitatively. The fastest operating power device is the series connection of comparatively low-voltage devices. For large-current operation, a uniformly operating pin-diode structure device is essential. An SOS is constructed from dozens of medium voltage (about 3kV) special hard-recovery diodes. This can shut off 2kA current at 10kV with in 10ns. The dynistor has n+pnp+ four layers and two electrodes. Serial-connected dynistors have the potential to replace thyratrons. These new devices can endure over 10 kA/cm2 at much higher voltage than their static breakdown values in the repetitive use more than 1011 times.

  14. The benefits of pulsed eddy currents for detection of cracks in non-magnetic alloys; Interet des courants de foucault pulses pour la detection de fissures dans les alliages

    Energy Technology Data Exchange (ETDEWEB)

    Billy, F.; Bernard, A.; Gros, P.O

    1997-12-01

    We have highlighted one inherent advantage of the Pulsed Eddy Current (PEC) technique which consists of analysing the measurement signal at times when no induced currents are created by the emitting coil. This result has been used to design sensors for the detection of deep subsurface flaws situated as much as 15 mm beneath the surface of stainless-steel with a conductivity of 10{sup 6} S/m. Our results have enabled us to recommend and support the PEC technique for the following applications: detecting surface-breaking flaws or degraded material, i.e. with a bad surface state; detecting subsurface flaws situated at depths of up to 15 mm in highly conductive and/or multi-layer materials. (K.A.)

  15. Effects of pulse current on energy consumption and removal of heavy metals during electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian R.; Ottosen, Lisbeth M.

    2012-01-01

    exchange membrane was the major contributor of energy consumption, and the pulse current could decrease the voltage drop of this part effectively. The overall removal of heavy metals in soil 1 (6–54%) was much higher than soil 2 (1–17%) due to the different acidification process and chemical speciation......The aims of this paper were to investigate the possibility for energy saving when using a pulsed electric field during electrodialytic soil remediation (EDR) and the effect of the pulsed current on removal of heavy metals. Eight experiments with constant and pulse current in the different...... industrially polluted soils were performed. At a current density of 0.1mA/cm2 in soil 1 and 0.2mA/cm2 in soil 2, there was no difference on energy consumption and removal of heavy metals between pulse current and constant current experiments, but at higher current experiments (i.e., 0.2mA/cm2 in soil 1 and 0...

  16. Effect of Pulsed Current TIG Welding Parameters on Pitting Corrosion Behaviour of AA6061 Aluminium Alloy

    Institute of Scientific and Technical Information of China (English)

    T. Senthil Kumar; V. Balasubramanian; M. Y. Sanavullah; S. Babu

    2007-01-01

    Medium strength aluminium alloy (Al-Mg-Si alloy) has gathered wide acceptance in the fabrication of light weight structures requiring a high strength-to weight ratio, such as transportable bridge girders, military vehicles, road tankers and railway transport systems. The preferred welding process for aluminium alloy is frequently TIG (tungsten inert gas) welding due to its comparatively easier applicability and better economy.In the case of single pass TIG welding of thinner section of this alloy, the pulsed current has been found beneficial due to its advantages over the conventional continuous current process. The use of pulsed current parameters has been found to improve the mechanical properties of the welds compared to those of continuous current welds of this alloy due to grain refinement occurring in the fusion zone. A mathematical model has been developed to predict pitting corrosion potential of pulsed current TIG welded AA6061 aluminium alloy.Factorial experimental design has been used to optimize the experimental conditions. Analysis of variance technique has been used to find out the significant pulsed current parameters. Regression analysis has been used to develop the model. Using the developed model pitting corrosion potential values have been estimated for different combinations of pulsed current parameters and the results are analyzed in detail.

  17. Terahertz pulsed photogenerated current in microdiodes at room temperature

    CERN Document Server

    Ilkov, Marjan; Manolescu, Andrei; Valfells, Agust

    2015-01-01

    Space-charge induced modulation of the diode current under photoemission leads to the formation of beamlets with time delay between formation corresponding to THz frequency. We investigate the effect of electron temperature and internal space-charge forces on the formation and persistence of the beamlets. We find that for low applied electric fields (less than 8MV/m) temperature effects are most important in causing beam degradation, whereas at higher fields intra-beamlet space-charge forces are dominant. The current modulation is most robust when there is only one beamlet present in the diode gap at a time, corresponding to a macroscopic version of the Coulomb blockade. It is shown that a vacuum microdiode can operate quite well as a tunable THz oscillator at room temperature with an applied electric field above 10 MV/m and diode gap on the order of 100 nanometers.

  18. Terahertz pulsed photogenerated current in microdiodes at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Ilkov, Marjan; Torfason, Kristinn; Manolescu, Andrei, E-mail: manoles@ru.is; Valfells, Ágúst [School of Science and Engineering, Reykjavik University, Menntavegur 1, IS-101 Reykjavik (Iceland)

    2015-11-16

    Space-charge modulation of the current in a vacuum diode under photoemission leads to the formation of beamlets with time periodicity corresponding to THz frequencies. We investigate the effect of the emitter temperature and internal space-charge forces on the formation and persistence of the beamlets. We find that temperature effects are most important for beam degradation at low values of the applied electric field, whereas at higher fields, intra-beamlet space-charge forces are dominant. The current modulation is most robust when there is only one beamlet present in the diode gap at a time, corresponding to a macroscopic version of the Coulomb blockade. It is shown that a vacuum microdiode can operate quite well as a tunable THz oscillator at room temperature with an applied electric field above 10 MV/m and a diode gap of the order of 100 nm.

  19. Electrochemical deposition and characterization of zinc-nickel alloys deposited by direct and pulse current

    Directory of Open Access Journals (Sweden)

    GORAN R. RADOVIC

    2002-09-01

    Full Text Available Chemical composition and phase structure of Zn-Ni alloys obtained by electrochemical deposition under various conditions were investigated. The alloys were deposited on a rotating disc electrode and steel panel from chloride solutions by direct and pulse current. The influence of the pulse plating variables (on-time, off-time, relation of off- and on-time on the composition, phase structure and corrosion properties were investigated. The phase composition affects the anticorrosive properties of Zn-Ni alloys during exposure to a corrosive agent (3 % NaCl solution. It was shown that a Zn-Ni alloy electrodeposited by pulse current with a pulse time of 1 ms and an off- and on-time ratio of 1 exhibits the best corrosion properties.

  20. Numerical analysis of transient keyhole shape in pulsed current plasma arc welding

    Institute of Scientific and Technical Information of China (English)

    孙俊华; 武传松

    2014-01-01

    Based on the characteristics of“one keyhole in a pulse”in pulsed current plasma arc welding (PAW),the transient variation process ofweld pool in a pulse cycle is simulated through the establishment ofcorresponding heat source model.And considering the effects ofgravitational force,plasma arc pressure and surface tension on the weld pool surface,the dynamic change features of the keyhole shape in a pulse cycle are calculated by using surface deformation equation. Experiments are conducted and validate that the calculated weld fusion line is in good agreement with the experimental results.

  1. Probing Pulsed Current Gas Metal Arc Welding for Modified 9Cr-1Mo Steel

    Science.gov (United States)

    Krishnan, S.; Kulkarni, D. V.; De, A.

    2015-04-01

    Modified 9Cr-1Mo steels are commonly welded using gas tungsten arc welding process for its superior control over the rate of heat input and vaporization loss of the key alloying elements although the rate electrode deposition remains restricted. Recent developments in pulsed current gas metal arc welding have significantly improved its ability to enhance the rate of electrode deposition with a controlled heat input rate while its application for welding of modified 9Cr-1Mo steels is scarce. The present work reports a detailed experimental study on the pulsed current gas metal arc welding of modified 9Cr-1Mo steels. The effect of the shielding gas, welding current, and speed on the weld bead profile, microstructure and mechanical properties are examined. The results show that the pulsed current gas metal arc welding with appropriate welding conditions can provide acceptable bead profile and mechanical properties in welds of modified 9Cr-1Mo steels.

  2. Non-Cyanide Electrodeposited Ag–PTFE Composite Coating Using Direct or Pulsed Current Deposition

    Directory of Open Access Journals (Sweden)

    Raymond Sieh

    2016-07-01

    Full Text Available The effects of FC-4 cationic surfactant on electrodeposited Ag–PTFE composite coating using direct or pulsed currents were studied using scanning electron microscope (SEM, energy dispersive X-ray (EDS, optical microscope, and a linear tribometer. FC-4:PTFE in various ratios were added to a non-cyanide succinimide silver complex bath. Direct or pulsed current method was used at a constant current density to enable comparison between both methods. A high incorporation rate of PTFE was successfully achieved, with pulsed current being highly useful in increasing the amount of PTFE in the composite coating. The study of coating wear under sliding showed that a large majority of the electrodeposited coatings still managed to adhere to the substrate, even after 10 wear cycles of sliding tests. Performance improvements were achieved on all the samples with a coefficient of friction (CoF between 0.06 and 0.12.

  3. Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse

    Energy Technology Data Exchange (ETDEWEB)

    Grishkov, V. E.; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2017-03-15

    Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse is analyzed within the kinetic approach. It is shown that the most efficient source of plasma waves is the nonlinear current arising due to the gradient of the energy density of the high-frequency field. Generation of plasma waves by the drag current is usually less efficient but not negligibly small at relatively high frequencies of electron–ion collisions. The influence of electron collisions on the excitation of plasma waves by pulses of different duration is described quantitatively.

  4. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J. J.; van der Meiden, H. J.; Morgan, T. W.; D.C. Schram,; De Temmerman, G.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 mu F) is parallel-coupled to the current regulated power supply. The current is transiently increased from i

  5. Effects of Pulsed Current and Pulsed Magnetic Field Complex Pretreatment on Martensite Transformation of Cr5 Steel during Continuous Cooling

    Institute of Scientific and Technical Information of China (English)

    Qing-chun LI; Li-juan LI; Guo-wei CHANG; Qi-jie ZHAI

    2015-01-01

    Carbide precipitation and martensite transformation in Cr5 steel have been observed in situ by high-temper-ature confocal laser-scanning microscopy.In this way,the influences of pulsed current and pulsed magnetic field complex pretreatment on carbide precipitation and martensite transformation during continuous cooling have been studied.The results show that the electropulsing complex pretreatment promotes the precipitation of M7 C3-type car-bides at high temperature,increases the start and finish temperatures of martensite transformation,and extends the phase transformation time.Martensite prefers to nucleate in the austenite with less precipitation of carbides due to the chemically homogeneous distribution of solute atoms.

  6. Design and Performance of a Novel Pancake Rogowski Coil for Measuring Pulse Currents%Design and Performance of a Novel Pancake Rogowski Coil for Measuring Pulse Currents

    Institute of Scientific and Technical Information of China (English)

    王春杰; 汲胜昌; 聂济宇; 欧小波; 韩钟健; 张乔根

    2011-01-01

    A novel pancake Rogowski coil without magnetic core is introduced in this paper. Owing to its special pancake winding structure, the coil is of low self-resistance and high self-inductance, and thus has excellent low frequency characteristic in the self-integral mode. Moreover, because of its unique installation method, the coil has a flexible sensitivity and can be applied under situations where toroidal air-core Rogowski coils or printed aircuit board (PCB) coils are not available. The parameters and performance of the pancake Rogowski coil are presented, and the principle of shielding is given. Measurements of step pulse current and oscillating pulse current by the coil are studied experimentally to illustrate its good linearity, reliable and flexible sensitivity and excellent frequency characteristic, especially its advantage in low frequency characteristic. The pancake Rogowski coil can be designed to assume round, square or rectangle shape, and has thus broad prospects in its application to the current measurement in such areas as plasma physics and pulsed power technology.

  7. RESULTS OF CALCULATION-EXPERIMENTAL INVESTIGATIONS OF ELECTRO-THERMAL RESISTIBILITY OF SHEET STEEL SAMPLES TO ACTION OF RATIONED COMPONENTS OF PULSED CURRENT OF ARTIFICIAL LIGHTING

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2016-06-01

    Full Text Available Purpose. Calculation and experimental researches of the electro-thermal resistibility of the steel sheet samples to action standard pulse current components of the artificial lightning with amplitude-time parameters (ATP, corresponded the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. Methodology. Electrophysics bases of technique of high tensions and large impulsive currents (LIC, and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring in them LIC. Сurrent amplitude ImA=±200 kA (with a tolerance of ±10 %; current action integral JA=2∙106 A2•s (with a tolerance of ±20 %; time, corresponding to the amplitude of the current ImA, tmA≤50 microseconds; the duration of the current flow τpA≤500 microseconds. Results. The results of the evaluation of the calculated and experimental studies of electro-thermal resistance of the samples of plates measuring 0,5 m  0,5 m stainless steel 1 mm thickness to the action on them artificial lightning impulse currents with rationed ATP on the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. A pulse A- component have a first amplitude 192 kA, the corresponding time of 34 μs, and the duration aperiodic component amplitude 804 A, corresponding to the time 9 ms. It has been shown that the long C- component current of artificial lightning can lead to keyhole these samples. The diameter of the holes in this thin steel sheet, which is formed during the flow of current C- components can reach 15 mm. The results of calculation and experiment agree within 28 %. Originality. For the first time in world practice on the generator large pulsed currents experimental studies of resistibility of sheet steel samples to the action of artificial lightning currents with critical parameters. Practical value. Using the results obtained in the practice of lightning protection will significantly improve the

  8. THREE-ELECTRODE AIR SWITCHBOARD WITH THE GRAPHITE ELECTRODES OF KATG-50 ON VOLTAGE TO ±50 KV AND IMPULSE CURRENT BY AMPLITUDE TO ±220 KA

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2015-04-01

    Full Text Available Purpose. Development and creation of the simplified construction of a high-voltage heavy-current air three-electrode switchboard with graphite electrodes, intended for operation in composition the powerful generator of large impulsive current of artificial of linear lightning. Methodology. Electrophysics bases of technique of high-voltage and scientific and technical bases of planning of devices of high-voltage impulsive technique. Results. Developed and made a new construction of a high-voltage heavy-current air three-electrode switchboard with the graphite electrodes of KATG-50 on nominal voltage ±50 kV. This construction of switchboard KATG-50 has been passed experimental approbation in composition the heavy-current bit chain of powerful high-voltage generator of the аperiodic impulses of current of artificial linear lightning rationed on operating foreign standards with amplitude of Im=±(200±20 кА at their duration τP=(350±35 μs at level 0,5∙Im. Originality. First in domestic practice of development and creation of high-voltage heavy-current switchboards for the generators of large impulse currents of artificial lightning the ground of necessity of the use for their basic and managing electrodes of electrical engineering graphite is carried out. Practical value. The developed and made high-voltage heavy-current switchboard of cascade-tray KATG-50 from application in its composition of graphite electrodes possesses an enhanceable working resource and enhanceable stability of wearing-out at the use of similar switchboard in the bit chain of powerful pulsed current of the imitated linear lightning.

  9. The early stage wheel fatigue crack detection using eddy current pulsed thermography

    Science.gov (United States)

    Peng, Jianping; Zhang, Kang; Yang, Kai; He, Zhu; Zhang, Yu; Peng, Chaoyong; Gao, Xiaorong

    2017-02-01

    The in-service wheel-set quality is one of critical challenges for railway safety, especially for the high-speed train. The defect in wheel tread, initiated by rolling contact fatigue (RCF) damage, is one of the most significant phenomena and has serious influence on rail industry. Eddy current pulsed thermography is studied to compensate the UT method for detection these early stage of fatigue cracks in wheel tread surface. This paper proposes approximately uniform magnetic field, excited by Helmholtz coils, based pulsed eddy current thermography to achieve open-view image and meet the irregular surface in wheel tread through numerical way. Some features are extracted and studied also to quantify the fatigue crack in term of eddy current pulsed thermography. The proposed method enhances the capability for cracks detection and quantitative evaluation compared with previous NDT method in railway.

  10. Effect of current pulses on fracture morphology in superplastic deformation of 2091 Al-Li alloy

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    The effect of current pulses on the fracture morphology in the superplastic deformation of 2091 AlLi alloy at two kinds of initial strain rate ((ε)1 = 3.33 × 10 -3 s-1;(ε)2= 3.33 × 10-2 s- 1 ) was investigated. Experimental results show that current pulse turns fracture of superplastic deformation at low strain rate from local interior fracture morphology to typical fracture by growth and interlinkage of cavities, and at high strain rate from rough grain boundary surface to smooth grain boundary surface. It is indicated that the characteristic, that current pulse promotes atomic diffusion, maintains an equiaxial grain microstructure at low strain rate, and accelerates the development of diffusional type of cavity and relaxes stress concentration at triple junction of grain boundaries at high strain rate, and makes the superplastic deformation at two kinds of strain rate show a normal superplastic fracture morphology.

  11. Pulse

    Science.gov (United States)

    ... resting for at least 10 minutes. Take the exercise heart rate while you are exercising. ... pulse rate can help determine if the person's heart is pumping. Pulse ... rate gives information about your fitness level and health.

  12. Fast pulsed operation of a small non-radioactive electron source with continuous emission current control.

    Science.gov (United States)

    Cochems, P; Kirk, A T; Bunert, E; Runge, M; Goncalves, P; Zimmermann, S

    2015-06-01

    Non-radioactive electron sources are of great interest in any application requiring the emission of electrons at atmospheric pressure, as they offer better control over emission parameters than radioactive electron sources and are not subject to legal restrictions. Recently, we published a simple electron source consisting only of a vacuum housing, a filament, and a single control grid. In this paper, we present improved control electronics that utilize this control grid in order to focus and defocus the electron beam, thus pulsing the electron emission at atmospheric pressure. This allows short emission pulses and excellent stability of the emitted electron current due to continuous control, both during pulsed and continuous operations. As an application example, this electron source is coupled to an ion mobility spectrometer. Here, the pulsed electron source allows experiments on gas phase ion chemistry (e.g., ion generation and recombination kinetics) and can even remove the need for a traditional ion shutter.

  13. Design of long-pulse fast wave current drive antennas for DIII-D

    Science.gov (United States)

    Baity, F. W.; Batchelor, D. B.; Bills, K. C.; Fogelman, C. H.; Jaeger, E. F.; Ping, J. L.; Riemer, B. W.; Ryan, P. M.; Stallings, D. C.; Taylor, D. J.; Yugo, J. J.

    1994-10-01

    Two new long-pulse fast wave current drive (FWCD) antennas will be installed on DIII-D in early 1994. These antennas will increase the available FWCD power from 2 MW to 6 MW for pulse lengths of up to 2 s, and to 4 MW for up to 10 s. Power for the new antennas is from two ASDEX-type 30- to 120-MHz transmitters. When operated at 90° phasing into a low-density plasma (˜4×1019m-3) with hot electrons (˜10 keV), these two new antennas are predicted to drive approximately 1 MA of plasma current.

  14. The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T.; Tarvainen, O.; Toivanen, V.; Peura, P.; Jones, P.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae FI-40014 (Finland); Noland, J.; Leitner, D. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2010-02-15

    Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount of bremsstrahlung radiation is significantly decreased.

  15. Effect of electric current pulse on grain growth in superplastic deformation of 2091 Al-Li alloy

    Institute of Scientific and Technical Information of China (English)

    刘志义; 许晓嫦; 崔建忠

    2003-01-01

    The effect of electric current pulse on the grain growth in the superplastic deformation of 2091 Al-Li alloy was investigated. Optical metallographic microstructure observation and average linear intercept measuring results show that at same strain, the grain size in the superplastic deformation loaded with electric current pulse is smaller than that unemploying electric current pulse, and so does the grain growth rate. TEM observation shows that the dislocation density at grain boundary in the superplastic deformation applied with electric current pulse is lower than that unemploying electric current pulse.It indicates that electric current pulse increases the rate of dislocation slip and climb in grain boundary, which leads to a decrease of both the density of the dislocation slipping across grain boundary at same strain rate and the driving force for grain growth, therefore the rate of grain growth decreases.The established model for grain growth shows an exponential relation of grain size with strain.

  16. Is there an Optimal Shape of the Defibrillation Shock: Constant Current vs. Pulsed Biphasic Waveforms

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2013-04-01

    Full Text Available Three waveforms for transthoracic defibrillation are assessed and compared: the Pulsed Biphasic Waveform (PBW, the Rectilinear Biphasic Waveform (RBW, and the "lossless" constant current (LLCC pulses. Two indices are introduced: 1 kf = W/W0 - the ratio between the delivered energy W and the energy W0 of a rectangular pulse with the same duration and electric charge; 2 ηC = W/WC0 - the level of utilizing the initially loaded capacitor energy WC0. The envisioned comparative study shows that ηC index is favorable for both PBW and LLCC, while kf of both RBW and LLCC demonstrates advantage over the PBW in the range of small inter-electrode thoracic impedances below 80 Ω. Some design considerations are also discussed. The attractive LLCC concept needs large and heavy inductive coil to support the constant current amplitude, besides it is capable to induce strong electromagnetic influences due to the complex current control. The RBW technology controls the delivery of current through a series of internal resistors which are, however, a source of high heat losses. The PBW implements controlled duty cycle of high-frequency chopped pulses to adapt the energy delivery in respect of the patient impedance measured at the beginning of the shock. PBW technology makes use of small capacitors which allows the construction of light weight and small-size portable devices for transthoracic defibrillation.

  17. Criteria for fluxon generation in long Josephson junctions by current pulses

    DEFF Research Database (Denmark)

    Sakai, S.; Samuelsen, Mogens Rugholm

    1987-01-01

    In recent measurements in the time domain on the fluxon shape in long Josephson junctions the fluxons were generated by a current pulse injected into one end. We present here a perturbation treatment of the fluxon generation which we compare with numerical experiments. The agreement turns out to ...... to be excellent. Applied Physics Letters is copyrighted by The American Institute of Physics....

  18. Low energy high current pulsed electron beam treatment for improving surface microstructure and properties

    Energy Technology Data Exchange (ETDEWEB)

    Wu, J; Allain-Bonasso, N; Zhang, X D; Hao, S Z; Grosdider, T; Dong, C [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, UMR-CNRS 3143), Universite Paul Verlaine-Metz, Ile du Saulcy, 57045 Metz (France); Zou, J X, E-mail: jiang.wu@univ-metz.fr, E-mail: thierry.grosdidier@univ-metz.fr [National Engineering Research Center of Light Alloy Net Forming, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2010-06-15

    Low energy high current pulsed electron beam (LEHCPEB) is a fairly new technique for surface modifications authorizing improvement in wear and corrosion properties as well as texture changes and hardening. This contribution highlights some microstructure modifications encountered at the surface of HCPEB treated steels and bulk metallic glasses taking into account the effects of surface melting and the effects of the induced stress.

  19. Catalytic graphitization of wood-based carbons with alumina by pulse current heating

    NARCIS (Netherlands)

    Hata, T; Ishimaru, K; Fujisawa, M; Bronsveld, P; Vystavel, T; De Hosson, J; Kikuchi, H; Nishizawa, T; Imamura, Y

    2005-01-01

    Japanese cedar was preheated at 500 degrees C and subsequently mixed with 40 mu m Al2O3 particles. A pulse current heating method was used for a 5-min carbonization step under a pressure of 50MPa in order to promote the graphitization at temperatures between 2000 and 2200 degrees C. The samples were

  20. Thermoelectric properties of SiC/C composites from wood charcoal by pulse current sintering

    NARCIS (Netherlands)

    Fujisawa, M; Hata, T; Bronsveld, P; Castro, [No Value; Tanaka, F; Kikuchi, H; Imamura, Y

    2005-01-01

    SiC/C composites were investigated by sintering a mix of wood charcoal and SiO2 powder (32-45 mu m) at 1400, 1600 and 1800 degrees C under N-2 atmosphere with a pulse current sintering method. Thermoelectric properties of SiC/C composites were investigated by measuring the Seebeck coefficient and th

  1. Pulsed Direct Current Electric Fields Enhance Osteogenesis in Adipose-Derived Stromal Cells

    OpenAIRE

    Hammerick, Kyle E.; James, Aaron W.; Huang, Zubin; Prinz, Fritz B.; Michael T. Longaker

    2009-01-01

    Adipose-derived stromal cells (ASCs) constitute a promising source of cells for regenerative medicine applications. Previous studies of osteogenic potential in ASCs have focused on chemicals, growth factors, and mechanical stimuli. Citing the demonstrated role electric fields play in enhancing healing in bone fractures and defects, we investigated the ability of pulsed direct current electric fields to drive osteogenic differentiation in mouse ASCs. Employing 50 Hz direct current electric fie...

  2. Large Aperture Low Threshold Current 980nm VCSELs Fabricated with Pulsed Anodic Oxidation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Pulsed anodic oxidation technique, a new way of forming current blocking layers, was successfully used in ridge-waveguide QW laser fabrication. This method was applied in 980 nm VCSELs fabrication to form a high-quality native oxide current blocking layer, which simplifies the device process. A significant reduction of threshold current and a distinguished device performance are achieved. The 500 μm diameter device has a current threshold as low as 0.48 W. The maximum CW operation output power at room tempe...

  3. Pulsed-Current Electrochemical Codeposition and Heat Treatment of Ti-Dispersed Ni-Matrix Layers

    Science.gov (United States)

    Janetaisong, Pathompong; Boonyongmaneerat, Yuttanant; Techapiesancharoenkij, Ratchatee

    2016-08-01

    An electrochemical deposition is a fast and cost-efficient process to produce film or coating. In this research, Ni-Ti electrodeposition is developed by codepositing a Ti-dispersed Ni-matrix layer from a Ni-plating solution suspended with Ti particles. To enhance the coating uniformity and control the atomic composition, the pulsed current was applied to codeposit Ni-Ti layers with varying pulse duty cycles (10 to 100 pct) and frequencies (10 to 100 Hz). The microstructures and compositions of the codeposited layers were analyzed by scanning electron microscopy, X-ray diffraction, and X-ray fluorescent techniques. The pulsed current significantly improved the quality of the Ni-Ti layer as compared to a direct current. The Ni-Ti layers could be electroplated with a controlled composition within 48 to 51 at. pct of Ti. The optimal pulse duty cycle and frequency are 50 pct and 10 Hz, respectively. The standalone Ni-49Ti layers were removed from copper substrates by selective etching method and subsequently heat-treated under Ar-fed atmosphere at 1423 K (1150 °C) for 5 hours. The phase and microstructures of the post-annealed samples exhibit different Ni-Ti intermetallic compounds, including NiTi, Ni3Ti, and NiTi2. Yet, the contamination of TiN and TiO2 was also present in the post-annealed samples.

  4. Effect of pulsed current welding on fatigue behaviour of high strength aluminium alloy joints

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramanian, V. [Department of Manufacturing Engineering, Annamalai University, Annamalai Nagar 608 002, Tamil Nadu (India)], E-mail: visvabalu@yahoo.com; Ravisankar, V. [Department of Manufacturing Engineering, Annamalai University, Annamalai Nagar 608 002, Tamil Nadu (India); Madhusudhan Reddy, G. [Metal Joining Section, Defence Metallurgical Research Laboratory (DMRL), Kanchanbag (P.O), Hyderabad 560 058 (India)

    2008-07-01

    High strength aluminium alloys (Al-Zn-Mg-Cu alloys) have gathered wide acceptance in the fabrication of light weight structures requiring high strength-to weight ratio, such as transportable bridge girders, military vehicles, road tankers and railway transport systems. The preferred welding processes of high strength aluminium alloy are frequently gas tungsten arc welding (GTAW) process and gas metal arc welding (GMAW) process due to their comparatively easier applicability and better economy. Weld fusion zones typically exhibit coarse columnar grains because of the prevailing thermal conditions during weld metal solidification. This often results inferior weld mechanical properties and poor resistance to hot cracking. In this investigation, an attempt has been made to refine the fusion zone grains by applying pulsed current welding technique. Rolled plates of 6 mm thickness have been used as the base material for preparing single pass welded joints. Single V butt joint configuration has been prepared for joining the plates. The filler metal used for joining the plates is AA 5356 (Al-5Mg (wt%)) grade aluminium alloy. Four different welding techniques have been used to fabricate the joints and they are: (i) continuous current GTAW (CCGTAW), (ii) pulsed current GTAW (PCGTAW), (iii) continuous current GMAW (CCGMAW) and (iv) pulsed current GMAW (PCGMAW) processes. Argon (99.99% pure) has been used as the shielding gas. Fatigue properties of the welded joints have been evaluated by conducting fatigue test using rotary bending fatigue testing machine. Current pulsing leads to relatively finer and more equi-axed grain structure in gas tungsten arc (GTA) and gas metal arc (GMA) welds. In contrast, conventional continuous current welding resulted in predominantly columnar grain structures. Grain refinement is accompanied by an increase in fatigue life and endurance limit.

  5. Optimization Of Pulsed Current Parameters To Minimize Pitting Corrosion İn Pulsed Current Micro Plasma Arc Welded Aısı 304l Sheets Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Kondapalli Siva Prasad

    2013-06-01

    Full Text Available Austenitic stainless steel sheets have gathered wide acceptance in the fabrication of components, which require high temperature resistance and corrosion resistance, such as metal bellows used in expansion joints in aircraft, aerospace and petroleum industry. In case of single pass welding of thinner sections of this alloy, Pulsed Current Micro Plasma Arc Welding (PCMPAW was found beneficial due to its advantages over the conventional continuous current process. This paper highlights the development of empirical mathematical equations using multiple regression analysis, correlating various process parameters to pitting corrosion rates in PCMPAW of AISI 304L sheets in 1 Normal HCl. The experiments were conducted based on a five factor, five level central composite rotatable design matrix. A Genetic Algorithm (GA was developed to optimize the process parameters for minimizing the pitting corrosion rates.

  6. Polarization-selective vortex-core switching by tailored orthogonal Gaussian-pulse currents

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Young-Sang; Lee, Ki-Suk; Jung, Hyunsung; Choi, Youn-Seok; Yoo, Myoung-Woo; Han, Dong-Soo; Im, Mi-Young; Fischer, Peter; Kim, Sang-Koog

    2011-05-01

    We experimentally demonstrate low-power-consumption vortex-core switching in magnetic nanodisks using tailored rotating magnetic fields produced with orthogonal and unipolar Gaussian-pulse currents. The optimal width of the orthogonal pulses and their time delay are found, from analytical and micromagnetic numerical calculations, to be determined only by the angular eigenfrequency ωD for a given vortex-state disk of polarization p, such that σ=1/ωD and Δt=π/2p/ωD. The estimated optimal pulse parameters are in good agreement with the experimental results. Finally, this work lays a foundation for energy-efficient information recording in vortex-core cross-point architecture.

  7. Manufacturing technology effect on current pulse handling performance of metallized polypropylene film capacitors

    Science.gov (United States)

    El-Husseini, M. H.; Venet, P.; Al-Majid, A.; Fathallah, M.; Rojat, G.; Ferreira, J. A.

    2003-09-01

    In this paper, the testing of the pulse-withstanding capability of metallized polypropylene film (MPPF) capacitors is reported. Four groups of capacitors having the same electrical characteristics but different geometry were considered for the test. Capacitors with long geometry seem to have poorer pulse handling performance for similar electrical stress conditions. However, the premature failure of one of the capacitor groups tested suggests that the quality of the end-edge contact is strongly dependent on the physical features of the manufacturing process. The end-edge contact plays a vital role in the current pulse handling capability of MPPF capacitors, which varies from a few hundred to several thousand discharging cycles depending on the geometry of the capacitor and the end-edge contact manufacturing process.

  8. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    Science.gov (United States)

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  9. Surface Crack Detection for Carbon Fiber Reinforced Plastic Materials Using Pulsed Eddy Current Based on Rectangular Differential Probe

    OpenAIRE

    Jialong Wu; Deqiang Zhou; Jun Wang

    2014-01-01

    Aiming at the surface defect inspection of carbon fiber reinforced composite, the differential and the direct measurement finite element simulation models of pulsed eddy current flaw detection were built. The principle of differential pulsed eddy current detection was analyzed and the sensitivity of defect detection was compared through two kinds of measurements. The validity of simulation results was demonstrated by experiments. The simulation and experimental results show that the pulsed ed...

  10. Temperature field at time of pulse current discharge in metal structure with elliptical embedding crack

    Institute of Scientific and Technical Information of China (English)

    FU Yu-ming; TIAN Zhen-guo; ZHENG Li-juan; LI Wei

    2008-01-01

    Theoretical analysis is made on the temperature field at the time of pulse current discharge in a metal structure with an elliptical embedding crack. In finding the temperature field, analogy between the current flow through an elliptical embedding crack and the fluid flow through a barrier is made based on the similarity principle. Boundary conditions derived from this theory are introduced so that the distribution of current density and the temperature field expressions can be obtained. The study provides a theoretic basis to the applications of stopping spatial crack with electromagnetic heating.

  11. DC link current simulation of voltage source inverter with random space vector pulse width modulation

    Directory of Open Access Journals (Sweden)

    Chen Guoqiang

    2016-01-01

    Full Text Available Aiming at analysis complexity, a simulation model is built and presented to analyze and demonstrate the characteristics of the direct current (DC link current of the three-phase two-level inverter with the random space vector pulse width modulation (SVPWM strategy. The developing procedure and key subsystems of the simulation model are given in detail. Several experiments are done using the simulation model. The results verify the efficiency and convenience of the simulation model and show that the random SVPWM scheme, especially the random switching frequency scheme, can efficiently suppress the harmonic peaks of the DC link current.

  12. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R., E-mail: dkillelea@luc.edu [Department of Chemistry and Biochemistry, Loyola University Chicago, 1068 W. Sheridan Rd., Chicago, Illinois 60660 (United States)

    2015-03-15

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  13. Saturation current and collection efficiency for ionization chambers in pulsed beams.

    Science.gov (United States)

    DeBlois, F; Zankowski, C; Podgorsak, E B

    2000-05-01

    Saturation currents and collection efficiencies in ionization chambers exposed to pulsed megavoltage photon and electron beams are determined assuming a linear relationship between 1/I and 1/V in the extreme near-saturation region, with I and V the chamber current and polarizing voltage, respectively. Careful measurements of chamber current against polarizing voltage in the extreme near-saturation region reveal a current rising faster than that predicted by the linear relationship. This excess current combined with conventional "two-voltage" technique for determination of collection efficiency may result in an up to 0.7% overestimate of the saturation current for standard radiation field sizes of 10X10 cm2. The measured excess current is attributed to charge multiplication in the chamber air volume and to radiation-induced conductivity in the stem of the chamber (stem effect). These effects may be accounted for by an exponential term used in conjunction with Boag's equation for collection efficiency in pulsed beams. The semiempirical model follows the experimental data well and accounts for both the charge recombination as well as for the charge multiplication effects and the chamber stem effect.

  14. Effect of Catalytic Pyrolysis Conditions Using Pulse Current Heating Method on Pyrolysis Products of Wood Biomass

    Directory of Open Access Journals (Sweden)

    Sensho Honma

    2014-01-01

    Full Text Available The influence of catalysts on the compositions of char and pyrolysis oil obtained by pyrolysis of wood biomass with pulse current heating was studied. The effects of catalysts on product compositions were analyzed using GC-MS and TEM. The compositions of some aromatic compounds changed noticeably when using a metal oxide species as the catalyst. The coexistence or dissolution of amorphous carbon and iron oxide was observed in char pyrolyzed at 800°C with Fe3O4. Pyrolysis oil compositions changed remarkably when formed in the presence of a catalyst compared to that obtained from the uncatalyzed pyrolysis of wood meal. We observed a tendency toward an increase in the ratio of polyaromatic hydrocarbons in the pyrolysis oil composition after catalytic pyrolysis at 800°C. Pyrolysis of biomass using pulse current heating and an adequate amount of catalyst is expected to yield a higher content of specific polyaromatic compounds.

  15. Charge and spin current oscillations in a tunnel junction induced by magnetic field pulses

    Science.gov (United States)

    Dartora, C. A.; Nobrega, K. Z.; Cabrera, G. G.

    2016-08-01

    Usually, charge and spin transport properties in tunnel junctions are studied in the DC bias regime and/or in the adiabatic regime of time-varying magnetic fields. In this letter, the temporal dynamics of charge and spin currents in a tunnel junction induced by pulsed magnetic fields is considered. At low bias voltages, energy and momentum of the conduction electrons are nearly conserved in the tunneling process, leading to the description of the junction as a spin-1/2 fermionic system coupled to time-varying magnetic fields. Under the influence of pulsed magnetic fields, charge and spin current can flow across the tunnel junction, displaying oscillatory behavior, even in the absence of DC bias voltage. A type of spin capacitance function, in close analogy to electric capacitance, is predicted.

  16. Effect of Catalytic Pyrolysis Conditions Using Pulse Current Heating Method on Pyrolysis Products of Wood Biomass

    Science.gov (United States)

    Honma, Sensho; Hata, Toshimitsu; Watanabe, Takashi

    2014-01-01

    The influence of catalysts on the compositions of char and pyrolysis oil obtained by pyrolysis of wood biomass with pulse current heating was studied. The effects of catalysts on product compositions were analyzed using GC-MS and TEM. The compositions of some aromatic compounds changed noticeably when using a metal oxide species as the catalyst. The coexistence or dissolution of amorphous carbon and iron oxide was observed in char pyrolyzed at 800°C with Fe3O4. Pyrolysis oil compositions changed remarkably when formed in the presence of a catalyst compared to that obtained from the uncatalyzed pyrolysis of wood meal. We observed a tendency toward an increase in the ratio of polyaromatic hydrocarbons in the pyrolysis oil composition after catalytic pyrolysis at 800°C. Pyrolysis of biomass using pulse current heating and an adequate amount of catalyst is expected to yield a higher content of specific polyaromatic compounds. PMID:25614894

  17. Domain walls, domain wall transformations and structural changes in permalloy nanowires when subjected to current pulses

    Energy Technology Data Exchange (ETDEWEB)

    Hempe, E.M. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Department of Physics, Universitaet Regensburg, Universitaetsstrasse 31, 93040 Regensburg (Germany); Klaeui, M.; Krzyk, S.; Ruediger, U. [Fachbereich Physik, Universitaet Konstanz, Universitaetsstrasse 10, 78457 Konstanz (Germany); Kasama, T. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Backes, D. [Fachbereich Physik, Universitaet Konstanz, Universitaetsstrasse 10, 78457 Konstanz (Germany); Laboratory for Micro- and Nanotechnology, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Junginger, F. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Fachbereich Physik, Universitaet Konstanz, Universitaetsstrasse 10, 78457 Konstanz (Germany); Heyderman, L.J. [Laboratory for Micro- and Nanotechnology, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Dunin-Borkowski, R. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Center for Electron Nanoscopy, DTU (Denmark)

    2007-12-15

    We report the direct transmission electron microscopy observation of spin structure transformations in nanoscale Permalloy zigzag wires due to Joule heating during the injection of current pulses. This heating is sufficient to overcome the energy barriers separating the different metastable domain wall spin structures. Due to the large energy barriers these are stable and observable at room temperature by off-axis electron holography and Fresnel imaging. The interaction between different domain walls is probed and the main pinning mechanism is determined to be the edge roughness. In addition to transformations, we also report on thermally assisted domain wall hopping between two pinning sites and structural changes that occur when the samples are subjected to even higher current pulses. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  18. Dosimetric response for crystalline and nanostructured aluminium oxide to a high-current pulse electron beam.

    Science.gov (United States)

    Nikiforov, S V; Kortov, V S

    2014-11-01

    The main thermoluminescent (TL) and dosimetric properties of the detectors based on anion-defective crystalline and nanostructured aluminium oxide after exposure to a high-current pulse electron beam are studied. TL peaks associated with deep-trapping centres are registered. It is shown that the use of deep-trap TL at 200-600°С allows registering absorbed doses up to 750 kGy for single-crystalline detectors and those up to 6 kGy for nanostructured ones. A wide range of the doses registered, high reproducibility of the TL signal and low fading contribute to a possibility of using single-crystalline and nanostructured aluminium oxide for the dosimetry of high-current pulse electron beams.

  19. Design of long-pulse fast wave current drive antennas for DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Baity, F.W.; Batchelor, D.B.; Bills, K.C.; Fogelman, C.H.; Jaeger, E.F.; Ping, J.L.; Riemer, B.W.; Ryan, P.M.; Stallings, D.C.; Taylor, D.J.; Yugo, J.J. (Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-8071 (United States))

    1994-10-15

    Two new long-pulse fast wave current drive (FWCD) antennas will be installed on DIII-D in early 1994. These antennas will increase the available FWCD power from 2 MW to 6 MW for pulse lengths of up to 2 s, and to 4 MW for up to 10 s. Power for the new antennas is from two ASDEX-type 30- to 120-MHz transmitters. When operated at 90[degree] phasing into a low-density plasma ([similar to]4[times]10[sup 19]m[sup [minus]3]) with hot electrons ([similar to]10 keV), these two new antennas are predicted to drive approximately 1 MA of plasma current.

  20. A High Voltage High Frequency Resonant Inverter for Supplying DBD Devices with Short Discharge Current Pulses

    OpenAIRE

    Bonnin, Xavier; Brandelero, Julio; Videau, Nicolas; Piquet, Hubert; Meynard, Thierry

    2014-01-01

    International audience; In this paper, the merits of a high-frequency resonant converter for supplying dielectric barrier discharges (DBD) devices are established. It is shown that, thanks to its high-frequency operating condition, such a converter allows to supply DBD devices with short discharge current pulses, a high repetition rate, and to control the injected power. In addition, such a topology eliminates the matter of connecting a high-voltage transformer directly across the DBD device ...

  1. Process Parameter Optimization of the Pulsed Current Argon Tungsten Arc Welding of Titanium Alloy

    Institute of Scientific and Technical Information of China (English)

    M.Balasubramanian; V.Jayabalan; V.Balasubramanian

    2008-01-01

    The selection of process parameters for obtaining optimal tensile properties in the pulsed current gas tungsten arc welding is presented. The tensile properties include ultimate tensile strength, yield strength and notch tensile strength. All these characteristics are considered together in the selection of process parameters by modified taguchi method to analyse the effect of each welding process parameter on tensile properties. Experimental results are furnished to illustrate the approach.

  2. Compaction of tool steels by pulsed electric current (PECS) sintering process

    OpenAIRE

    Postal, Stefano

    2014-01-01

    This study had two major purposes: the microstructural investigation of High Chromium White Iron (HCWI) sintered with Pulsed Electric Current Sintering (PECS) and the evaluation of the abrasion resistance of high chromium white iron mixed with different amounts of Hadfield Steel. The objective was to obtain dense high chromium white iron compacts with fine and uniform carbide and grain structure. The materials included in the study were gas atomized high chromium white iron (2.60 wt% C, 19.48...

  3. A close-up of the lower part of a 13 kA current lead. The high-temperature superconductor (on the left in the photo) with the low-temperature superconductor (on the right). Resting in liquid helium, the low-temperature superconductor is connected to the bus-bars conveying the current to the LHC magnets.

    CERN Multimedia

    2004-01-01

    A close-up of the lower part of a 13 kA current lead. The high-temperature superconductor (on the left in the photo) with the low-temperature superconductor (on the right). Resting in liquid helium, the low-temperature superconductor is connected to the bus-bars conveying the current to the LHC magnets.

  4. A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

    CERN Multimedia

    2004-01-01

    A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

  5. Crystallization of Ti33Cu67 metallic glass under high-current density electrical pulses

    Directory of Open Access Journals (Sweden)

    Mali Vyacheslav

    2011-01-01

    Full Text Available Abstract We have studied the phase and structure evolution of the Ti33Cu67 amorphous alloy subjected to electrical pulses of high current density. By varying the pulse parameters, different stages of crystallization could be observed in the samples. Partial polymorphic nanocrystallization resulting in the formation of 5- to 8-nm crystallites of the TiCu2 intermetallic in the residual amorphous matrix occurred when the maximum current density reached 9.7·108 A m-2 and the pulse duration was 140 μs, though the calculated temperature increase due to Joule heating was not enough to reach the crystallization temperature of the alloy. Samples subjected to higher current densities and higher values of the evolved Joule heat per unit mass fully crystallized and contained the Ti2Cu3 and TiCu3 phases. A common feature of the crystallized ribbons was their non-uniform microstructure with regions that experienced local melting and rapid solidification. PACS: 81; 81.05.Bx; 81.05.Kf.

  6. Evaluation of conductor stresses in a pulsed high-current toroidal transformer

    Energy Technology Data Exchange (ETDEWEB)

    Turchi, Peter J [Los Alamos National Laboratory; Rousculp, Chritopher L [Los Alamos National Laboratory; Reass, William A [Los Alamos National Laboratory; Oro, David M [Los Alamos National Laboratory; Merrill, Frank E [Los Alamos National Laboratory; Greigo, Jeffery R [Los Alamos National Laboratory; Reinovsky, Robert E [Los Alamos National Laboratory

    2009-01-01

    The Precision, High-Energy Density, Liner Implosion Experiment (PHELIX) pulsed power driver is currently under development at Los Alamos National Laboratory. When operational PHELIX will provide 5-10 MAmps of peak current with pulse rise-time of {approx} 5-10 ms. Crucial to the performance of PHELIX is a multi-turn primary, single-turn secondary, current step-up toroidal transformer, R{sub major} {approx} 30 cm, R{sub minor} {approx} 10 cm. The transformer lifetime should exceed 100 shots. Therefore it is essential that the design be robust enough to survive the magnetic stresses produced by high currents. In order to evaluate their design, two methods have been utilized. First, an analytical evaluation has been performed. By identifying the magnetic forces as J{sub 1}{sup 2}/2 {del}L{sub 1} + J{sub 1}J{sub 2}{del}M{sub 12}, where J{sub 1} and J{sub 2} are currents in two circuits, coupled by mutual inductance M{sub 12} and L{sub 1} is the self-inductance of the circuit carrying current J{sub 1}, analytical estimates of stress can be obtained. These results are then compared to a computational MHD model of the same system and to a full finite-element, electromagnetic simulation.

  7. Influence of current density on microstructure of pulse electrodeposited tin coatings

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Ashutosh; Bhattacharya, Sumit; Sen, Ranjan; Reddy, B.S.B. [Department of Metallurgical and Materials Engineering, Indian Institute of Technology-Kharagpur, Kharagpur-721302 (India); Fecht, H.-J. [Institut fuer Mikro- und Nanomaterialien, Universitaet Ulm, D-89081 Ulm (Germany); Das, Karabi, E-mail: karabi@metal.iitkgp.ernet.in [Department of Metallurgical and Materials Engineering, Indian Institute of Technology-Kharagpur, Kharagpur-721302 (India); Das, Siddhartha [Department of Metallurgical and Materials Engineering, Indian Institute of Technology-Kharagpur, Kharagpur-721302 (India)

    2012-06-15

    Pulse electrodeposited tin coatings on copper substrate have been synthesized from an aqueous solution containing sodium stannate (Na{sub 2}SnO{sub 3}.3H{sub 2}O) and sodium hydroxide (NaOH). The effect of current density on surface morphology of the deposits has been investigated. As deposited coatings are characterized by X-ray diffraction, scanning electron microscopy, electron backscatter diffraction, and line profile analysis. The X-ray diffraction analysis shows that the deposits consist of tetragonal ({beta}-Sn) structure with microcrystalline grains. The deposits plated at lower current density exhibit (110) texture which decreases with increasing current densities. The effects of current density on Cu-Sn diffusion and whisker growth of the electrodeposited tin coatings are also reported here. - Highlights: Black-Right-Pointing-Pointer Pulse electrodeposition of Sn from aqueous alkaline solution without adding any organic additive. Black-Right-Pointing-Pointer Effect of current density on morphology and whisker growth in tin coatings aged for 1 year. Black-Right-Pointing-Pointer Solution bath is stable and can be operated over a wide range of current density.

  8. Ultrahigh-current proton beams from short-pulse laser-solid interactions

    Energy Technology Data Exchange (ETDEWEB)

    Badziak, J; Jablowski, S; Parys, P; Rosinski, M; Suchanska, R; Wolowski, J [Institute of Plasma Physics and Laser Microfusion, EURATOM Association, Warsaw (Poland); Antici, P; Fuchs, J; Lancia, L; Mancic, A [LULI, Ecole Polytechnique, CNRS, CEA, UPMC, Route de Saclay, 91128 Palaiseau (France); Szydlowski, A [Andrzej Soltan Institute for Nuclear Studies, Warsaw (Poland)], E-mail: badziak@ifpilm.waw.pl

    2008-05-01

    The results of studies of high-current proton beam generation from thin (1-3{mu}m) solid targets irradiated by 0.35-ps laser pulse of intensity up to 2x10{sup 19} W/cm{sup 2} are reported. It is shown that the proton beams of multi-MA currents and multi-TA/cm{sup 2} current densities at the source can be produced when the laser-target interaction conditions approach the skin-layer ponderomotive acceleration requirements. The current and energy spectrum of protons remarkably depend on the target structure. In particular, using a double-layer Au/PS target (plastic covered by 0.1 - 0.2{mu}m Au front layer) results in two-fold higher proton currents and higher proton energies than in the case of a plastic target.

  9. Large Aperture Low Threshold Current 980 nm VCSELs Fabricated with Pulsed Anodic Oxidation

    Institute of Scientific and Technical Information of China (English)

    CUI Jin-jiang; NING Yong-qiang; LI Te; LIU Guang-yu; ZHANG Yan; PENG Biao; SUN Yan-fang; WANG Li-jun

    2007-01-01

    Pulsed anodic oxidation technique, a new way of forming current blocking layers, was successfully used in ridge-waveguide QW laser fabrication. This method was applied in 980 nm VCSELs fabrication to form a high-quality native oxide current blocking layer, which simplifies the device process. A significant reduction of threshold current and a distinguished device performance are achieved. The 500 μm diameter device has a current threshold as low as 048 W. The maximum CW operation output power at room temperature is 1.48 W. The lateral divergence angle θ‖ and vertical divergence angle θ⊥ are as low as 15.3° and 13.8° without side-lobes at a current of 6 A.

  10. Efficiency of pulse high-current generator energy transfer into plasma liner energy

    Science.gov (United States)

    Oreshkin, V. I.

    2013-08-01

    The efficiency of capacitor-bank energy transfer from a high-current pulse generator into kinetic energy of a plasma liner has been analyzed. The analysis was performed using a model including the circuit equations and equations of the cylindrical shell motion. High efficiency of the energy transfer into kinetic energy of the liner is shown to be achieved only by a low-inductance generator. We considered an "ideal" liner load in which the load current is close to zero in the final of the shell compression. This load provides a high (up to 80%) efficiency of energy transfer and higher stability when compressing the liner.

  11. Resistive states created in superconducting NbTiN filaments by an electrical current pulse

    Directory of Open Access Journals (Sweden)

    K. Harrabi

    2015-03-01

    Full Text Available We have observed as a function of the time the appearance of the voltage caused by a larger-than-critical (I > Ic step-pulse of current in narrow NbTiN strips at 4.2 K. Different current intensities produced either phase-slip centres characterized by a voltage saturating with the time, or ever expanding hot spots. These dissipative structures occur after a measurable delay time, whose dependence upon the ratio I/Ic can be analysed through a Ginzburg-Landau theory to yield a unique adjustable time constant.

  12. Electrical discharge machining (EDM) of Inconel 718 by using copper electrode at higher peak current and pulse duration

    Science.gov (United States)

    Ahmad, S.; Lajis, M. A.

    2013-12-01

    This experimental work is an attempt to investigate the performance of Copper electrode when EDM of Nickel Based Super Alloy, Inconel 718 is at higher peak current and pulse duration. Peak current, Ip and pulse duration (pulse on-time), ton are selected as the most important electrical pulse parameters. In addition, their influence on material removal rate (MRR), electrode wear rate (EWR), and surface roughness (Ra) are experimentally investigated. The ranges of 10 mm diameter of Copper electrode are used to EDM of Inconel 718. After the experiments, MRR, EWR, and Ra of the machined surfaces need to be measured in order to evaluate the performance of the EDM process. In order to obtain high MRR, higher peak current in range of 20A to 40A and pulse duration in range of 200μs to 400μs were used. Experimental results have shown that machining at a highest peak current used of 40A and the lowest pulse duration of 200μs used for the experiment yields the highest material removal rate (MRR) with value 34.94 mm3/min, whereas machining at a peak current of 20A and pulse duration of 400μs yields the lowest electrode wear rate (EWR) with value -0.0101 mm3/min. The lowest surface roughness (Ra) is 8.53 μm achieved at a lowest peak current used of 20A and pulse duration of 200μs.

  13. Composition and Morphology of Zn-Co Alloy Coatings Deposited by Means of Pulse Plating Containing Reverse Current

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The influence of bath constituents and pulse parameters on cobalt content, surface morphologies and grain size of Zn-Co alloy deposits was studied using a pulse plating technique with a squarewave current containing reverse pulse. It is found that Zn-Co alloy coatings obtained from the bath with the cobalt ion concentration over 60 wt% have a higher cobalt content in deposits. The results of pulse plating show that the average current density and reverse anodic current density amongst the variables investigated have very strong effects on the cobalt content in the Zn-Co alloy deposits. It is possible to electrodeposit Zn-Co alloy coatings with 10-90 wt% cobalt by modulating pulse parameters. The grain size, surface appearance and internal stress in the deposit were improved significantly by introducing the reverse current.

  14. Surface modification of polyacrylonitrile co-polymer membranes using pulsed direct current nitrogen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Dipankar; Neogi, Sudarsan; De, Sirshendu, E-mail: sde@che.iitkgp.ernet.in

    2015-12-31

    Low temperature plasma treatment using pulsed direct current discharge of nitrogen gas was employed to enhance hydrophilicity of the polyacrylonitrile co-polymer membranes. The membranes were characterized in terms of morphology, structure, hydrophilicity, and membrane performance. Properties and functional groups on the surface of polyacrylonitrile co-polymer membranes were investigated by contact angle, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Effects of plasma conditions, namely, pulsed voltage, duty cycle and treatment time on increase in membrane hydrophilicity were studied. Permeability of treated membrane was increased by 47% and it was retained up to 70 days. Surface etching due to plasma treatment was confirmed by weight loss of the treated membranes. Due to surface etching, average pore size increased and rejection of 200 kDa polyethylene glycol decreased to about 70% for the treated membrane. Oxygen and nitrogen functional groups were responsible for surface hydrophilicity. - Highlights: • Surface modification of polyacrylonitrile co-polymer membranes by pulsed direct current nitrogen plasma • Hydrophilic functional groups incorporated on the membrane surface • Significant enhancement of the permeability and wettability of the membranes • Water contact angle increased with storage time and finally stabilized.

  15. Effects of Electric Pulse Current on the Aging Kinetics of 2219 Aluminum Alloy

    Directory of Open Access Journals (Sweden)

    Jiao Zhang

    2014-01-01

    Full Text Available The conventional aging experiments and the low density electric pulse current (LDEPC for short added aging experiments, with the self-made positive and negative alternating pulse power equipment, were conducted to study the influence of LDEPC on the dynamics of phase transformation in 2219 aluminum alloy by means of measuring the variation of hardness with aging time. The results showed that the hardness in both aging systems increased with the increasing of aging time until it reached the peak value; then it gradually reduced. The hardness of LDEPC added aging is generally greater than the conventional one before the peak aging time. The Avrami dynamics equation of conventional isothermal aging was obtained based on the hardness evolution law. The effects of electromigration and ponderomotive force were introduced into the Avrami empirical equation; in turn, the dynamics equation of LDEPC added aging was established. At last, the isothermal transformation curves of both the regular aging and the LDEPC added aging were derived which revealed that the nucleation rate, as well as the growth rate, was promoted by electric pulse current. The research work provided the theoretical support for the regulation of the coupling energy field on the dynamics of phase transformation in 2219 aluminum alloy.

  16. Various categories of defects after surface alloying induced by high current pulsed electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Dian [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Tang, Guangze, E-mail: oaktang@hit.edu.cn [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Ma, Xinxin [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Gu, Le [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Sun, Mingren [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Wang, Liqin [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2015-10-01

    Highlights: • Four kinds of defects are found during surface alloying by high current electron beam. • Exploring the mechanism how these defects appear after irradiation. • Increasing pulsing cycles will help to get good surface quality. • Choosing proper energy density will increase surface quality. - Abstract: High current pulsed electron beam (HCPEB) is an attractive advanced materials processing method which could highly increase the mechanical properties and corrosion resistance. However, how to eliminate different kinds of defects during irradiation by HCPEB especially in condition of adding new elements is a challenging task. In the present research, the titanium and TaNb-TiW composite films was deposited on the carburizing steel (SAE9310 steel) by DC magnetron sputtering before irradiation. The process of surface alloying was induced by HCPEB with pulse duration of 2.5 μs and energy density ranging from 3 to 9 J/cm{sup 2}. Investigation of the microstructure indicated that there were several forms of defects after irradiation, such as surface unwetting, surface eruption, micro-cracks and layering. How the defects formed was explained by the results of electron microscopy and energy dispersive spectroscopy. The results also revealed that proper energy density (∼6 J/cm{sup 2}) and multi-number of irradiation (≥50 times) contributed to high quality of alloyed layers after irradiation.

  17. Manipulation of magnetic carriers for drug delivery using pulsed-current high T {sub c} superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yung [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: yscha@anl.gov; Chen, Lihua [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 (United States); Askew, Thomas [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Physics Department, Kalamazoo College, Kalamazoo, MI 49006 (United States); Veal, Boyd [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Hull, John [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)

    2007-04-15

    An innovative method of manipulating magnetic carriers is proposed, and its feasibility for drug delivery and therapy is demonstrated experimentally. The proposed method employs pulsed-field solenoid coils with high-critical- temperature (T {sub c}) superconductor inserts. Pulsed current is used to magnetize and de-magnetize the superconductor insert. The proposed method was demonstrated to be able to (1) move magnetic particles, ranging in size from a few millimeters to 10 {mu}m, with strong enough forces over a substantial distance, (2) hold the particles at a designated position as long as needed, and (3) reverse the processes and retrieve the particles. We further demonstrated that magnetic particles can be manipulated in a stationary environment, in water flow, and in simulated blood (water/glycerol mixture) flow.

  18. Manipulation of magnetic carriers for drug delivery using pulsed-current high Tc superconductors

    Science.gov (United States)

    Cha, Yung; Chen, Lihua; Askew, Thomas; Veal, Boyd; Hull, John

    2007-04-01

    An innovative method of manipulating magnetic carriers is proposed, and its feasibility for drug delivery and therapy is demonstrated experimentally. The proposed method employs pulsed-field solenoid coils with high-critical- temperature ( Tc) superconductor inserts. Pulsed current is used to magnetize and de-magnetize the superconductor insert. The proposed method was demonstrated to be able to (1) move magnetic particles, ranging in size from a few millimeters to 10 μm, with strong enough forces over a substantial distance, (2) hold the particles at a designated position as long as needed, and (3) reverse the processes and retrieve the particles. We further demonstrated that magnetic particles can be manipulated in a stationary environment, in water flow, and in simulated blood (water/glycerol mixture) flow.

  19. Mechanism for negative corona current pulse in CO sub 2 -SF sub 6 mixtures

    CERN Document Server

    Zahoranova, A; Simor, M; Cernak, M

    2003-01-01

    Current waveforms of first negative corona pulses have been measured in CO sub 2 -SF sub 6 mixtures over a pressure range extending from 6.65 to 50 kPa and various overvoltages. Effects of changing cathode secondary electron emission were studied using a copper cathode coated by CuI and graphite. For a given set of experimental conditions it is concluded that in the mixtures containing up to 30% of SF sub 6 the negative corona pulse is associated with the formation of a cathode-directed streamer-like ionizing wave in the immediate vicinity of the cathode. This is in contrast to the discharge behaviour in air-SF sub 6 and N sub 2 -SF sub 6 mixtures, where in similar conditions the discharge develops according to a multi-avalanche Townsend mechanism. (rapid communication)

  20. Kuulus dress ka Evelinile!

    Index Scriptorium Estoniae

    2009-01-01

    Proua Evelin Ilves kinkis Eestis esinenud popstaar Madonnale eesti rahvusmotiividega dressid. Sarnased spordirõivad tulevad müügile ka Tallinnas Viru keskuses Bastioni esinduskaupluses. Proua Evelin Ilvesele valmistatakse ainulaadsed valgest kangast dressid

  1. Kuulus dress ka Evelinile!

    Index Scriptorium Estoniae

    2009-01-01

    Proua Evelin Ilves kinkis Eestis esinenud popstaar Madonnale eesti rahvusmotiividega dressid. Sarnased spordirõivad tulevad müügile ka Tallinnas Viru keskuses Bastioni esinduskaupluses. Proua Evelin Ilvesele valmistatakse ainulaadsed valgest kangast dressid

  2. Effect of Reverse Pulse Current Duration on the Corrosion and Wear Performance of Ni-W Nanolaminate Coatings

    Science.gov (United States)

    Shreeram, Devesh Dadhich; Bedekar, Vikram; Li, Shengxi; Jagtap, Rohit; Cong, Hongbo; Doll, Gary L.

    2017-08-01

    The effects of varying the reverse pulse current duration (τ = 0 s, 1 s, 5 s, and 10 s) were evaluated on the composition, crystallinity, hardness, corrosion resistance, and tribological performance of nanolaminate Ni-W coatings deposited by pulsed reverse current electrodeposition. With the deposition conditions used in this study, it was found that a reverse current duration of τ = 1 s produced a coating that was both highly corrosion resistant and wear resistant.

  3. Microstructures and properties of zirconium-702 irradiated by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shen [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Cai, Jie [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Engineering Institute of Advanced Manufacturing and Modern Equipment Technology, Jiangsu University, Zhenjiang 212013 (China); Lv, Peng; Zhang, Conglin; Huang, Wei [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Guan, Qingfeng, E-mail: guanqf@mail.ujs.edu.cn [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China)

    2015-09-01

    Highlights: • Zirconium-702 irradiated by high current pulsed electron beam was investigated. • Irradiated surface was melted and martensitic phase transformation occurred. • High density dislocations and deformation twins were formed in melted layer. • Micropores and ultrafine structures were also obtained on the irradiated surface. • Microhardness and corrosion resistance were improved after HCPEB irradiation. - Abstract: The microstructure, hardness and corrosion resistance of zirconium-702 before and after high-current pulsed electron beam (HCPEB) irradiation have been investigated. The microstructure evolution and surface morphologies of the samples were characterized by using X-ray diffraction (XRD), optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The experimental results indicate that the sample surface was melted after HCPEB irradiation, and martensitic phase transformation occurred. Besides, two kinds of craters as well as ultrafine structures were obtained in the melted layer. TEM observations suggest that high density dislocations and deformation twins were formed after HCPEB irradiation. With the increasing of pulses, microhardness of the irradiated samples was increased from the initial 178 Hv to 254 Hv. The corrosion resistance was tested by using electrode impedance spectroscopy (EIS) and potentiodynamic polarization curves. Electrochemical results show that, after HCPEB irradiation, all the samples had better corrosion resistance in 1 mol HNO{sub 3} solution compared to the initial one, among which the 5-pulsed sample owned the best corrosion resistance. Ultrafine structures, martensitic phase transformation, surface porosities, dislocations and deformation twins are believed to be the dominant reasons for the improvement of the hardness and corrosion resistance.

  4. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    Science.gov (United States)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  5. Progress in pulsed-current Karl Fischer coulometry using diaphragm-free cells.

    Science.gov (United States)

    Nordmark, U; Cedergren, A

    2000-07-01

    Factors influencing the accuracy of water determinations using diaphragm-free, pulsed current Karl Fischer (KF) coulometry were investigated with the new Metrohm 756 instrument. Results obtained with commercially available reagents from Riedel-deHaen and Merck were compared with home-made ones that were especially designed to minimize the formation of iodine-consuming reduction products generated in the cathode reaction. Positive errors in the range 2-5% were found for the commercial reagents as compared to 0.2-1% for the home-made ones which were buffered at about pH 10 containing modifiers like chloroform, hexanol or ethylene glycol. Except for the composition of the KF-reagent, the cathode current density and the titration rate were found to be critical parameters for the accuracy of the determinations. For all reagents investigated, the best results were obtained for the maximum generator current 400 mA (corresponding to a current density of 1,400 mA cm(-2)) in combination with a maximum titration rate of 2,000 microg min(-1). Surprisingly, the errors found under optimum conditions for the pulse technique were always somewhat larger than the corresponding values obtained with continuous coulometry.

  6. Surface Crack Detection for Carbon Fiber Reinforced Plastic Materials Using Pulsed Eddy Current Based on Rectangular Differential Probe

    Directory of Open Access Journals (Sweden)

    Jialong Wu

    2014-01-01

    Full Text Available Aiming at the surface defect inspection of carbon fiber reinforced composite, the differential and the direct measurement finite element simulation models of pulsed eddy current flaw detection were built. The principle of differential pulsed eddy current detection was analyzed and the sensitivity of defect detection was compared through two kinds of measurements. The validity of simulation results was demonstrated by experiments. The simulation and experimental results show that the pulsed eddy current detection method based on rectangular differential probe can effectively improve the sensitivity of surface defect detection of carbon fiber reinforced composite material.

  7. Effects of pulse current on properties of electrodeposited RE-Ni-W-P-SiC composite coating

    Institute of Scientific and Technical Information of China (English)

    GUO Zhong-cheng; ZHU Xiao-yun; XU Rui-dong

    2004-01-01

    Effects of pulse current on properties of electrodeposited RE-Ni-W-P-SiC composite coating were studied. The results show that hardness of the pulse current electrodeposited composite coatings is higher than that of the direct current electrodeposited composite coatings while other parameters are the same. Otherwise, the deposited velocity is higher, and wear resistance and corrosion resistance of the pulse current electrodeposited composite coatings are also improved when the average current density is 10 A/dm2 , pulse frequency is 800 Hz and duty ratio is 1: 5. The hardness of the coating as-deposited is HV500 - 700, and it reaches HV1300 after heat treatment at 400 ℃ for 1 h.

  8. Self-Consistent Model for Pulsed Direct-Current N2 Glow Discharge

    Institute of Scientific and Technical Information of China (English)

    Liu Chengsen; Wang Dezhen

    2005-01-01

    A self-consistent analysis of a pulsed direct-current (DC) N2 glow discharge is presented. The model is based on a numerical solution of the continuity equations for electron and ions coupled with Poisson's equation. The spatial-temporal variations of ionic and electronic densities and electric field are obtained. The electric field structure exhibits all the characteristic regions of a typical glow discharge (the cathode fall, the negative glow, and the positive column).Current-voltage characteristics of the discharge can be obtained from the model. The calculated current-voltage results using a constant secondary electron emission coefficient for the gas pressure 133.32 Pa are in reasonable agreement with experiment.

  9. Predictive Pulse Pattern Current Modulation Scheme for Harmonic Reduction in Three-Phase Multidrive Systems

    DEFF Research Database (Denmark)

    Davari, Pooya; Yang, Yongheng; Zare, Firuz

    2016-01-01

    of them can lead to the cancellation of specific harmonics. This paper proposes a new cost-effective harmonic mitigation solution for multi-drive systems using a predictive pulse pattern current modulation control strategy. The proposed technique applies suitable interaction among parallel drive units......The majority of the industrial motor drive systems are equipped with the conventional line-commutated front-end rectifiers, and being one of the main sources of harmonics in the power line. While a parallel combination of these drive units elevates current quality issues, a proper arrangement...... at the rectification stage to synthesize sinusoidal input currents. The input voltage sensing is avoided in order to minimize the number of required sensors, and the grid synchronization also has been implemented based on a common Phase-Locked-Loop (PLL) using the DC-link capacitor voltage ripple. Experimental results...

  10. Microstructures and properties of zirconium-702 irradiated by high current pulsed electron beam

    Science.gov (United States)

    Yang, Shen; Cai, Jie; Lv, Peng; Zhang, Conglin; Huang, Wei; Guan, Qingfeng

    2015-09-01

    The microstructure, hardness and corrosion resistance of zirconium-702 before and after high-current pulsed electron beam (HCPEB) irradiation have been investigated. The microstructure evolution and surface morphologies of the samples were characterized by using X-ray diffraction (XRD), optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The experimental results indicate that the sample surface was melted after HCPEB irradiation, and martensitic phase transformation occurred. Besides, two kinds of craters as well as ultrafine structures were obtained in the melted layer. TEM observations suggest that high density dislocations and deformation twins were formed after HCPEB irradiation. With the increasing of pulses, microhardness of the irradiated samples was increased from the initial 178 Hv to 254 Hv. The corrosion resistance was tested by using electrode impedance spectroscopy (EIS) and potentiodynamic polarization curves. Electrochemical results show that, after HCPEB irradiation, all the samples had better corrosion resistance in 1 mol HNO3 solution compared to the initial one, among which the 5-pulsed sample owned the best corrosion resistance. Ultrafine structures, martensitic phase transformation, surface porosities, dislocations and deformation twins are believed to be the dominant reasons for the improvement of the hardness and corrosion resistance.

  11. Research on Defects Inspection of Solder Balls Based on Eddy Current Pulsed Thermography

    Science.gov (United States)

    Zhou, Xiuyun; Zhou, Jinlong; Tian, Guiyun; Wang, Yizhe

    2015-01-01

    In order to solve tiny defect detection for solder balls in high-density flip-chip, this paper proposed feasibility study on the effect of detectability as well as classification based on eddy current pulsed thermography (ECPT). Specifically, numerical analysis of 3D finite element inductive heat model is generated to investigate disturbance on the temperature field for different kind of defects such as cracks, voids, etc. The temperature variation between defective and non-defective solder balls is monitored for defects identification and classification. Finally, experimental study is carried on the diameter 1mm tiny solder balls by using ECPT and verify the efficacy of the technique. PMID:26473871

  12. Research on defects inspection of solder balls based on eddy current pulsed thermography.

    Science.gov (United States)

    Zhou, Xiuyun; Zhou, Jinlong; Tian, Guiyun; Wang, Yizhe

    2015-10-13

    In order to solve tiny defect detection for solder balls in high-density flip-chip, this paper proposed feasibility study on the effect of detectability as well as classification based on eddy current pulsed thermography (ECPT). Specifically, numerical analysis of 3D finite element inductive heat model is generated to investigate disturbance on the temperature field for different kind of defects such as cracks, voids, etc. The temperature variation between defective and non-defective solder balls is monitored for defects identification and classification. Finally, experimental study is carried on the diameter 1mm tiny solder balls by using ECPT and verify the efficacy of the technique.

  13. Research on Defects Inspection of Solder Balls Based on Eddy Current Pulsed Thermography

    Directory of Open Access Journals (Sweden)

    Xiuyun Zhou

    2015-10-01

    Full Text Available In order to solve tiny defect detection for solder balls in high-density flip-chip, this paper proposed feasibility study on the effect of detectability as well as classification based on eddy current pulsed thermography (ECPT. Specifically, numerical analysis of 3D finite element inductive heat model is generated to investigate disturbance on the temperature field for different kind of defects such as cracks, voids, etc. The temperature variation between defective and non-defective solder balls is monitored for defects identification and classification. Finally, experimental study is carried on the diameter 1mm tiny solder balls by using ECPT and verify the efficacy of the technique.

  14. Pulse-driven LED circuit with transformer-based current balance technique

    Science.gov (United States)

    Kwak, S.-S.

    2014-12-01

    Light emitting diodes (LEDs) have been gradually used for backlight modules for liquid crystal display as a substitute for cold cathode fluorescent lamps. In most of LED applications, it is required to connect several LED strings in parallel to limit the dc voltage level to be applied to the single LED string. Due to considerable current variations through each LED string with inevitable parameter deviations as well as temperature and ageing effects, techniques to balance currents flowing through LED strings are required for LED drivers. This article proposes a pulse-driven LED circuit with transformer-based current balancing scheme, which can simply regulate currents through the LED strings. The transformers are placed in series with the LED strings in such a way that the LED currents are automatically balanced. Since the developed current sharing technique employs no dissipative resistors and no linear-mode transistors, the proposed driver has high efficiency, low power dissipation and reduced thermal problems. In addition, the presented driver with no additional semiconductor devices and no additional controllers can provide a simple and a cost-effective current balancing solution, compared to conventional approaches. Thus, the proposed LED driver can feature a simple, highly efficient, reliable and cost-effective method. The presented LED driver is verified with experimental results.

  15. Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry.

    Science.gov (United States)

    Guerreiro, Gabriela V; Zaitouna, Anita J; Lai, Rebecca Y

    2014-01-31

    Here we report the characterization of an electrochemical mercury (Hg(2+)) sensor constructed with a methylene blue (MB)-modified and thymine-containing linear DNA probe. Similar to the linear probe electrochemical DNA sensor, the resultant sensor behaved as a "signal-off" sensor in alternating current voltammetry and cyclic voltammetry. However, depending on the applied frequency or pulse width, the sensor can behave as either a "signal-off" or "signal-on" sensor in square wave voltammetry (SWV) and differential pulse voltammetry (DPV). In SWV, the sensor showed "signal-on" behavior at low frequencies and "signal-off" behavior at high frequencies. In DPV, the sensor showed "signal-off" behavior at short pulse widths and "signal-on" behavior at long pulse widths. Independent of the sensor interrogation technique, the limit of detection was found to be 10nM, with a linear dynamic range between 10nM and 500nM. In addition, the sensor responded to Hg(2+) rather rapidly; majority of the signal change occurred in <20min. Overall, the sensor retains all the characteristics of this class of sensors; it is reagentless, reusable, sensitive, specific and selective. This study also highlights the feasibility of using a MB-modified probe for real-time sensing of Hg(2+), which has not been previously reported. More importantly, the observed "switching" behavior in SWV and DPV is potentially generalizable and should be applicable to most sensors in this class of dynamics-based electrochemical biosensors. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. A pulsed-power generator merging inductive voltage and current adders and its switch trigger application example.

    Science.gov (United States)

    Li, Lee; Yafeng, Ge; Heqin, Zhong; Bin, Yu; Longjun, Xie

    2013-07-01

    A pulsed-power generator using inductive adder technology is proposed for the case of a discharge gap. The merit of this generator is to merge the pulsed-voltage and pulsed-current adders via the dual secondary windings with special circuit. For the nonlinear impedance in any discharge gap, the standalone voltage-pulse and current-pulse can be outputted successively by this generator. The proposed generator is especially useful for the common resolution of implementing pulse discharge at less cost. As an application example, a compact trigger prototype was developed to compatibly use in the gas-insulated and vacuum switches. Experiments achieved good results that the triggered switches showed stable performance and long life. If the basic circuit of this proposed generator is regarded as a pulsed-generating unit, a certain number of such units connected in parallel can be expected to form a general device with generating greater breakdown-voltage and sustained-current pulses for discharge gaps.

  17. Microstructure and Temperature Distribution in ZnAl2O4 Sintered Body by Pulse Electric Current

    Institute of Scientific and Technical Information of China (English)

    Dongming ZHANG; Zhengyi FU; Jingkun GUO

    2003-01-01

    Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismatch. lt is the evidence that periodical temperature field existed during pulse electric current sintering of nonconductive materials.The distance between high temperature areas was related to die diameter.

  18. Novel high peak current pulsed diode laser sources for direct material processing

    Science.gov (United States)

    Traub, M.; Bock, M.; Hoffmann, H.-D.; Bartram, M.

    2007-02-01

    Diode laser systems are well established for applications which demand high continuous wave (cw) power. These applications are material processing like cutting and welding of metals as well as polymers where diode laser systems are less expensive and more compact than solid state lasers. Even though the optical output power and the beam quality of diode lasers are increasing steadily, the use of these sources is generally limited to cw applications. For processes during which ablating of material is demanded, however, conventional diode lasers are inferior compared to pulsed solid state lasers as diode lasers suffer from the absence of optical intracavity q-switching. Some examples of these applications are coating removal and marking. To overcome this drawback, we have developed several diode laser systems that use high peak-current drivers and thereby allow to operate the diode lasers at currents up to 500 A. The pulse source was tested with fiber coupled single emitters, conventional diode lasers and customized AR-coated diode laser bars. With the new diode laser driver, a peak output power of 250 W can be achieved with pulse durations of approx. 100 ns. Polarization coupling of two bars increases the power by a factor of two. Thereby an output power of 500 W can be demonstrated. These systems reach an intensity of 27 MW/cm2 per diode laser bar which is sufficient for ablating processes. We will demonstrate the design of the prototype system as well as results of marking and coating removal experiments with the system.

  19. High voltage pulsed current in collagen realignment, synthesis, and angiogenesis after Achilles tendon partial rupture

    Directory of Open Access Journals (Sweden)

    Érika P. Rampazo

    2016-01-01

    Full Text Available ABSTRACT Objective To verify the efficacy of high voltage pulsed current in collagen realignment and synthesis and in angiogenesis after the partial rupturing of the Achilles tendon in rats. Method Forty male Wistar rats were randomized into four groups of 10 animals each: sham, cathodic stimulation, anodic stimulation, and alternating stimulation. Their Achilles tendons were submitted to direct trauma by a free-falling metal bar. Then, the treatment was administered for six consecutive days after the injury. In the simulation group, the electrodes were positioned on the animal, but the device remained off for 30 minutes. The other groups used a frequency of 120 pps, sensory threshold, and the corresponding polarity. On the seventh day, the tendons were removed and sent for histological slide preparation for birefringence and Picrosirius Red analysis and for blood vessel quantification. Results No significant difference was observed among the groups regarding collagen realignment (types I or III collagen or quantity of blood vessels. Conclusion High voltage pulsed current for six consecutive days was not effective in collagen realignment, synthesis, or angiogenesis after the partial rupturing of the Achilles tendon in rats.

  20. High voltage pulsed current in collagen realignment, synthesis, and angiogenesis after Achilles tendon partial rupture

    Science.gov (United States)

    Rampazo, Érika P.; Liebano, Richard E.; Pinfildi, Carlos Eduardo; Folha, Roberta A. C.; Ferreira, Lydia M.

    2016-01-01

    ABSTRACT Objective To verify the efficacy of high voltage pulsed current in collagen realignment and synthesis and in angiogenesis after the partial rupturing of the Achilles tendon in rats. Method Forty male Wistar rats were randomized into four groups of 10 animals each: sham, cathodic stimulation, anodic stimulation, and alternating stimulation. Their Achilles tendons were submitted to direct trauma by a free-falling metal bar. Then, the treatment was administered for six consecutive days after the injury. In the simulation group, the electrodes were positioned on the animal, but the device remained off for 30 minutes. The other groups used a frequency of 120 pps, sensory threshold, and the corresponding polarity. On the seventh day, the tendons were removed and sent for histological slide preparation for birefringence and Picrosirius Red analysis and for blood vessel quantification. Results No significant difference was observed among the groups regarding collagen realignment (types I or III collagen) or quantity of blood vessels. Conclusion High voltage pulsed current for six consecutive days was not effective in collagen realignment, synthesis, or angiogenesis after the partial rupturing of the Achilles tendon in rats. PMID:27556387

  1. Surface modification of Al-Pb alloy by high current pulsed electron beam

    Institute of Scientific and Technical Information of China (English)

    LU You; LI Shi-long; AN Jian; LIU Yong-bing

    2006-01-01

    Al-Pb alloy was modified by high current pulsed electron beam and the microstructure, hardness and tribological characteristics were characterized by scanning electron microscopy, electronic microanalysis probe microanalysis, Knoop hardness indentation and pin-on-disc type wear testing machine. The results show that the microstructure and hardness can be greatly improved, and the modification layer consists of a molten zone, an overlapped zone of heat-affected and quasistatic thermal stress-affected zone and a transition zone followed by the substrate. The tribological properties of high current pulsed electron beam irradiated Al-Pb alloy are correspondingly improved largely. Optical observation and scanning electron microscopy analysis reveal that the low wear rate and lowest level in coefficient of friction at high load level for irradiated Al-Pb alloy are due to the formation of a lubricious tribolayer covering the worn surface, which is a mixture of Al2O3, Pb3O4 and silicate. The wear mode varies from oxidative wear at low load to film spalling at high load and, finally, adhesive wear.

  2. Eddy Current Pulsed Thermography with Different Excitation Configurations for Metallic Material and Defect Characterization.

    Science.gov (United States)

    Tian, Gui Yun; Gao, Yunlai; Li, Kongjing; Wang, Yizhe; Gao, Bin; He, Yunze

    2016-06-08

    This paper reviews recent developments of eddy current pulsed thermography (ECPT) for material characterization and nondestructive evaluation (NDE). Due to the fact that line-coil-based ECPT, with the limitation of non-uniform heating and a restricted view, is not suitable for complex geometry structures evaluation, Helmholtz coils and ferrite-yoke-based excitation configurations of ECPT are proposed and compared. Simulations and experiments of new ECPT configurations considering the multi-physical-phenomenon of hysteresis losses, stray losses, and eddy current heating in conjunction with uniform induction magnetic field have been conducted and implemented for ferromagnetic and non-ferromagnetic materials. These configurations of ECPT for metallic material and defect characterization are discussed and compared with conventional line-coil configuration. The results indicate that the proposed ECPT excitation configurations can be applied for different shapes of samples such as turbine blade edges and rail tracks.

  3. Eddy Current Pulsed Thermography with Different Excitation Configurations for Metallic Material and Defect Characterization

    Directory of Open Access Journals (Sweden)

    Gui Yun Tian

    2016-06-01

    Full Text Available This paper reviews recent developments of eddy current pulsed thermography (ECPT for material characterization and nondestructive evaluation (NDE. Due to the fact that line-coil-based ECPT, with the limitation of non-uniform heating and a restricted view, is not suitable for complex geometry structures evaluation, Helmholtz coils and ferrite-yoke-based excitation configurations of ECPT are proposed and compared. Simulations and experiments of new ECPT configurations considering the multi-physical-phenomenon of hysteresis losses, stray losses, and eddy current heating in conjunction with uniform induction magnetic field have been conducted and implemented for ferromagnetic and non-ferromagnetic materials. These configurations of ECPT for metallic material and defect characterization are discussed and compared with conventional line-coil configuration. The results indicate that the proposed ECPT excitation configurations can be applied for different shapes of samples such as turbine blade edges and rail tracks.

  4. A new high current laboratory and pulsed homopolar generator power supply at the University of Texas

    Science.gov (United States)

    Floyd, J. E.; Aanstoos, T. A.

    1984-03-01

    The University of Texas at Austin is constructing a facility for research in pulse power technology for the Center for Electromechanics at the Balcones Research Center. The facility, designed to support high-current experiments, will be powered by six homopolar generators, each rated at 10 MJ and arranged to allow matching the requirements of resistive and inductive loads at various voltage and current combinations. Topics covered include the high bay, the power supply configuration and parameters, the speed and field control, and the magnetic circuit. Also considered are the removable air-cooled brushes, the water-cooled field coils, the hydraulic motor sizing and direct coupling, the low-impedance removable field coils, and the hydrostatic bearing design.

  5. Eddy Current Modeling and Measuring in Fast-Pulsed Resistive Magnets

    CERN Document Server

    Arpaia, P; Gollucio, G; Montenero, G

    2010-01-01

    A method for modeling and measuring electromagnetic transients due to eddy currents in fast-pulsed resistive magnets is proposed. In particular, an equivalent-circuit model and a method for time-domain measurements of eddy currents are presented. The measurements are needed for an accurate control of the magnetic field quality to ensure adequate stability and performance of the particle beam in particle accelerators in dynamic conditions (field ramps up to about 700 T/s). In the second part, the results of experiments for model definition, identification, and validation are discussed. The tests were carried out on a quadrupole of Linac4, a new linear particle accelerator under construction at CERN (European Organization for Nuclear Research).

  6. Hysteresis Current Control Based Shunt Active Power Filter for Six Pulse Ac/Dc Converter

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Pandey

    2017-02-01

    Full Text Available In this paper the simulation of Shunt Active power Filter using P-Q theory and PI controller has been presented. This SAPF compensates the harmonic currents drawn by three phase six pulse AC/DC converter. The process of compensation is done by calculating the instantaneous reactive power losses using p-q theory and the PI controller to reduce the ripple voltage of the dc capacitor of the PWM-VSI. This approach is different from conventional approach and provides very effective solution. In this simulation we use hysteresis band current controller (HCC for switching the VSI inverter. The simulation has been done for both steady state and transient conditions

  7. The eddy current induced in the pulsed bump magnet for the CSNS/RCS injection

    Institute of Scientific and Technical Information of China (English)

    SONG Jin-Xing; KANG Wen; HUO Li-Hua; HAO Yao-Dou; WANG Lei

    2011-01-01

    The injecton pulsed bending bump magnets of Rapid Cycling Synchrotron (RCS) in China Spallar tion Neutron Source (CSNS) consist of four horizontal bending (BH) magnets and four vertical bending (BV)magnets. The BH magnets are operated at a repetition rate of 25 Hz and are excited with a trapezoid rectangle waveform with about 1.6 milliseconds duration. The eddy current is induced in BH magnets and in the end plates it is expected to be large, so the heat generation is of our great concern. In this paper, the eddy current loss of the BH magnet has been investigated and calculated by using a coupling method of 3D electromagnetic and thermal analysis. The accuracy of the analysis is confirmed by testing the prototype BH magnet. The end plate temperature of the BH magnet provided with slit cuts has been decreased obviously and met the requirements.

  8. Effect of pulsed current and post weld aging treatment on tensile properties of argon arc welded high strength aluminium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramanian, V. [Department of Manufacturing Engineering, Annamalai University, Annamalai Nagar, Tamil Nadu 608002 (India)], E-mail: visvabalu@yahoo.com; Ravisankar, V. [Department of Manufacturing Engineering, Annamalai University, Annamalai Nagar, Tamil Nadu 608002 (India); Reddy, G. Madhusudhan [Metal Joining Section, Defence Metallurgical Research Laboratory, Kanchanbag (P.O.), Hyderabad 560058 (India)

    2007-06-25

    This paper reveals the effect of pulsed current and post weld aging treatment on tensile properties of argon arc welded AA7075 aluminium alloy. This alloy has gathered wide acceptance in the fabrication of light weight structures requiring high strength-to-weight ratio, such as transportable bridge girders, military vehicles, road tankers and railway transport systems. The preferred welding processes of high strength aluminium alloy are frequently gas tungsten arc welding (GTAW) process and gas metal arc welding (GMAW) process due to their comparatively easier applicability and better economy. Weld fusion zones typically exhibit coarse columnar grains because of the prevailing thermal conditions during weld metal solidification. This often results inferior weld mechanical properties and poor resistance to hot cracking. In this investigation, an attempt has been made to refine the fusion zone grains by applying pulsed current welding technique. Four different welding techniques have been used to fabricate the joints and they are: (i) continuous current GTAW (CCGTAW), (ii) pulsed current GTAW (PCGTAW), (iii) continuous current GMAW (CCGMAW) and (iv) pulsed current GMAW (PCGMAW) processes. As welded joint strength is much lower than the base metal strength and hence, a simple aging treatment has been given to improve the tensile strength of the joints. Current pulsing leads to relatively finer and more equi-axed grain structure in GTA and GMA welds. In contrast, conventional continuous current welding resulted in predominantly columnar grain structures. Post weld aging treatment is accompanied by an increase in tensile strength and tensile ductility.

  9. Analytical description of generation of the residual current density in the plasma produced by a few-cycle laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Silaev, A. A., E-mail: silaev@appl.sci-nnov.ru; Vvedenskii, N. V., E-mail: vved@appl.sci-nnov.ru [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod 603950 (Russian Federation); University of Nizhny Novgorod, Nizhny Novgorod 603950 (Russian Federation)

    2015-05-15

    When a gas is ionized by a few-cycle laser pulse, some residual current density (RCD) of free electrons remains in the produced plasma after the passage of the laser pulse. This quasi-dc RCD is an initial impetus to plasma polarization and excitation of the plasma oscillations which can radiate terahertz (THz) waves. In this work, the analytical model for calculation of RCD excited by a few-cycle laser pulse is developed for the first time. The dependences of the RCD on the carrier-envelope phase (CEP), wavelength, duration, and intensity of the laser pulse are derived. It is shown that maximum RCD corresponding to optimal CEP increases with the laser pulse wavelength, which indicates the prospects of using mid-infrared few-cycle laser pulses in the schemes of generation of high-power THz pulses. Analytical formulas for optimal pulse intensity and maximum efficiency of excitation of the RCD are obtained. Basing on numerical solution of the 3D time-dependent Schrödinger equation for hydrogen atoms, RCD dependence on CEP is calculated in a wide range of wavelengths. High accuracy of analytical formulas is demonstrated at the laser pulse parameters which correspond to the tunneling regime of ionization.

  10. Structural and phase transformations in zinc and brass wires under heating with high-density current pulse

    Science.gov (United States)

    Pervikov, A. V.

    2016-06-01

    The work is focused on revealing the mechanism of structure and phase transformations in the metal wires under heating with a high-density current pulse (the electric explosion of wires, EEWs). It has been demonstrated on the example of brass and zinc wires that the transition of a current pulse with the density of j ≈ 3.3 × 107 A/cm2 results in homogeneous heating of the crystalline structure of the metal/alloy. It has been determined that under heating with a pulse of high-density current pulse, the electric resistance of the liquid phases of zinc and brass decreases as the temperature increases. The results obtained allow for a conclusion that the presence of the particles of the condensed phase in the expanding products of EEW is the result of overheating instabilities in the liquid metal.

  11. Pulse-Current-Induced Switching of Ta/CoFeB/MgO with Perpendicular Magnetic Anisotropy

    Science.gov (United States)

    Hung, Yu-Ming; Rehm, Laura; Wolf, Georg; Kent, Andrew D.

    2015-03-01

    We study current-induced switching of thin magnetic layers with perpendicular magnetic anisotropy using in-plane currents and the spin-Hall effect in the quasi-static (swept current) and pulsed-current regimes. Our aim is to investigate the dynamics and efficiency of spin-transfer switching. The layer stacks consists of β-Ta(5nm)/Co40Fe40B20(0.8nm)/MgO(2nm)/Ta(2nm) layers on oxidized silicon substrates. Hall bar structures with dimensions of 15 × 180 μm2 and cross shaped devices with width of 6 μm are investigated with DC transport and pulse measurement, respectively. In DC transport experiments, we could switch the magnetization states reproducibly by varying the in-plane field and current. In pulsed experiments, we measured the dependence of the switching probability on pulse amplitude and duration in the presence of an in-plane field. A histogram analysis indicates the existence of intermediate states and suggests incoherent magnetization switching. Nearly 100% switching probability could be achieved at high enough pulse amplitude of 25.5 MA/cm2 with 10 ns pulse duration and an applied field of ~120 mT. Supported by SRC-INDEX program.

  12. Nonlinear MHD simulation of current drive by multi-pulsed coaxial helicity injection in spherical torus

    Science.gov (United States)

    Kanki, Takashi; Nagata, Masayoshi; Kagei, Yasuhiro

    2011-10-01

    The dynamics of structures of magnetic field, current density, and plasma flow generated during multi-pulsed coaxial helicity injection in spherical torus is investigated by 3-D nonlinear MHD simulations. During the driven phase, the flux and current amplifications occur due to the merging and magnetic reconnection between the preexisting plasma in the confinement region and the ejected plasma from the gun region involving the n = 1 helical kink distortion of the central open flux column (COFC). Interestingly, the diamagnetic poloidal flow which tends toward the gun region is then observed due to the steep pressure gradients of the COFC generated by ohmic heating through an injection current winding around the inboard field lines, resulting in the formation of the strong poloidal flow shear at the interface between the COFC and the core region. This result is consistent with the flow shear observed in the HIST. During the decay phase, the configuration approaches the axisymmetric MHD equilibrium state without flow because of the dissipation of magnetic fluctuation energy to increase the closed flux surfaces, suggesting the generation of ordered magnetic field structure. The parallel current density λ concentrated in the COFC then diffuses to the core region so as to reduce the gradient in λ, relaxing in the direction of the Taylor state.

  13. Guiding out-migrating juvenile sea lamprey (Petromyzon marinus) with pulsed direct current

    Science.gov (United States)

    Johnson, Nicholas S.; Miehls, Scott M.

    2014-01-01

    Non-physical stimuli can deter or guide fish without affecting water flow or navigation and therefore have been investigated to improve fish passage at anthropogenic barriers and to control movement of invasive fish. Upstream fish migration can be blocked or guided without physical structure by electrifying the water, but directional downstream fish guidance with electricity has received little attention. We tested two non-uniform pulsed direct current electric systems, each having different electrode orientations (vertical versus horizontal), to determine their ability to guide out-migrating juvenile sea lamprey (Petromyzon marinus) and rainbow trout (Oncorhynchus mykiss). Both systems guided significantly more juvenile sea lamprey to a specific location in our experimental raceway when activated than when deactivated, but guidance efficiency decreased at the highest water velocities tested. At the electric field setting that effectively guided sea lamprey, rainbow trout were guided by the vertical electrode system, but most were blocked by the horizontal electrode system. Additional research should characterize the response of other species to non-uniform fields of pulsed DC and develop electrode configurations that guide fish over a range of water velocity.

  14. Pulsed Current-Voltage-Induced Perturbations of a Premixed Propane/Air Flame

    Directory of Open Access Journals (Sweden)

    Jacob. B. Schmidt

    2011-01-01

    Full Text Available The effect of millisecond wide sub-breakdown pulsed voltage-current induced flow perturbation has been measured in premixed laminar atmospheric pressure propane/air flame. The flame equivalence ratios were varied from 0.8 to 1.2 with the flow speeds near 1.1 meter/second. Spatio-temporal flame structure changes were observed through collection of CH (A-X and OH (A-X chemiluminescence and simultaneous spontaneous Raman scattering from N2. This optical collection scheme allows us to obtain a strong correlation between the measured gas temperature and the chemiluminescence intensity, verifying that chemiluminescence images provide accurate measurements of flame reaction zone structure modifications. The experimental results suggest that the flame perturbation is caused by ionic wind originating only from the radial positive space-charge distribution in/near the cathode fall. A net momentum transfer acts along the annular space discharge distribution in the reaction zone at or near the cathode fall which modifies the flow field near the cathodic burner head. This radially inward directed body force appears to enhance mixing similar to a swirl induced modification of the flame structure. The flame fluidic response exhibit a strong dependence on the voltage pulse width ≤10 millisecond.

  15. Surface treatment of 0.20% C carbon steel by high-current pulsed electron beam

    Institute of Scientific and Technical Information of China (English)

    XU Guo-cheng; FU Shi-you; GUAN Qing-feng

    2006-01-01

    A high-current pulsed electron beam(HCPEB) generated on the system of Nadezhda-2 was applied to improve the microstructure and performance of 0.20% C low carbon steel. Surface layers of the samples bombarded by explosive electron beam at different pulses was observed by using electron microscopy. The physical model of the thermal-stress process and related modification mechanism as a result of HCPEB irradiation was also investigated. After HCPEB post treatments, obvious changes in microstructure and significant hardening occur in the depth of 200-250 μm from the surface after HCPEB irradiation. Rapid heating and subsequent rapid solidification induce heavy plastic deformation, which results in that the laminated structure of pearlite is substituted by dispersive rounded-like cementites in the near-surface. The effect of HCPEB treatment can reach more than 500 m depth from the surface. The original crystalline structure is changed to a different degree that grows with the numbers of bombardment, and in the surface layer amorphous states and nanocrystaline structures consisting of grains of γ-phase and cementite are found. The violent stress induced by HCPEB irradiation is the origin of the nanostructured and amorphous structure formation.

  16. High rate deposition of thin film cadmium sulphide by pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lisco, F., E-mail: F.Lisco@lboro.ac.uk [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Kaminski, P.M.; Abbas, A.; Bowers, J.W.; Claudio, G. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, via Orabona 4, 70126 Bari (Italy); Walls, J.M. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom)

    2015-01-01

    Cadmium Sulphide (CdS) is an important n-type semiconductor widely used as a window layer in thin film photovoltaics Copper Indium Selenide, Copper Indium Gallium (di)Selenide, Copper Zinc Tin Sulphide and Cadmium Telluride (CdTe). Cadmium Sulphide has been deposited using a number of techniques but these techniques can be slow (chemical bath deposition and Radio Frequency sputtering) or the uniformity and the control of thickness can be relatively difficult (close space sublimation). In this paper we report on the development of a process using pulsed Direct Current magnetron sputtering which allows nanometre control of thin film thickness using time only. The CdS thin films deposited in this process are highly uniform and smooth. They exhibit the preferred hexagonal structure at room temperature deposition and they have excellent optical properties. Importantly, the process is highly stable despite the use of a semi-insulating magnetron target. Moreover, the process is very fast. The deposition rate using 1.5 kW of power to a 6-inch circular magnetron was measured to be greater than 8 nm/s. This makes the process suitable for industrial deployment. - Highlights: • Pulsed DC magnetron sputtering of CdS • High deposition rate deposition • Uniform, pinhole free films.

  17. Surface Modification of Light Alloys by Low-Energy High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    X. D. Zhang

    2012-01-01

    Full Text Available This paper reviews results obtained by the research groups developing the low-energy high-current pulsed electron beam (LEHCPEB in Dalian (China and Metz (France on the surface treatment of light alloys. The pulsed electron irradiation induces an ultra-fast thermal cycle at the surface combined with the formation of thermal stress and shock waves. As illustrated for Mg alloys and Ti, this results in deep subsurface hardening (over several 100 μm which improves the wear resistance. The analysis of the top surface melted surface of light alloys also often witnesses evaporation and condensation of chemical species. This phenomenon can significantly modify the melt chemistry and was also suggested to lead to the development of specific solidification textures in the rapidly solidified layer. The potential use of the LEHCPEB technique for producing thermomechanical treatments under the so-called heating mode and, thus, modify the surface crystallographic texture, and enhance solid-state diffusion is also demonstrated in the case of the FeAl intermetallic compound.

  18. Study on Nanostructures Induced by High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    Bo Gao

    2012-01-01

    Full Text Available Four techniques using high-current pulsed electron beam (HCPEB were proposed to obtain surface nanostructure of metal and alloys. The first method involves the distribution of several fine Mg nanoparticles on the top surface of treated samples by evaporation of pure Mg with low boiling point. The second technique uses superfast heating, melting, and cooling induced by HCPEB irradiation to refine the primary phase or the second phase in alloys to nanosized uniform distributed phases in the matrix, such as the quasicrystal phase Mg30Zn60Y10 in the quasicrystal alloy Mg67Zn30Y3. The third technique involves the refinement of eutectic silicon phase in hypereutectic Al-15Si alloys to fine particles with the size of several nanometers through solid solution and precipitation refinement. Finally, in the deformation zone induced by HCPEB irradiation, the grain size can be refined to several hundred nanometers, such as the grain size of the hypereutectic Al-15Si alloys in the deformation zone, which can reach ~400 nm after HCPEB treatment for 25 pulses. Therefore, HCPEB technology is an efficient way to obtain surface nanostructure.

  19. Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Guerreiro, Gabriela V.; Zaitouna, Anita J.; Lai, Rebecca Y., E-mail: rlai2@unl.edu

    2014-01-31

    Graphical abstract: -- Highlights: •An electrochemical Hg(II) sensor based on T–Hg(II)–T sensing motif was fabricated. •A methylene blue-modified DNA probe was used to fabricate the sensor. •Sensor performance was evaluated using ACV, CV, SWV, and DPV. •The sensor behaves as a “signal-off” sensor in ACV and CV. •The sensor behaves as either a “signal-on” or “signal-off” sensor in SWV and DPV. -- Abstract: Here we report the characterization of an electrochemical mercury (Hg{sup 2+}) sensor constructed with a methylene blue (MB)-modified and thymine-containing linear DNA probe. Similar to the linear probe electrochemical DNA sensor, the resultant sensor behaved as a “signal-off” sensor in alternating current voltammetry and cyclic voltammetry. However, depending on the applied frequency or pulse width, the sensor can behave as either a “signal-off” or “signal-on” sensor in square wave voltammetry (SWV) and differential pulse voltammetry (DPV). In SWV, the sensor showed “signal-on” behavior at low frequencies and “signal-off” behavior at high frequencies. In DPV, the sensor showed “signal-off” behavior at short pulse widths and “signal-on” behavior at long pulse widths. Independent of the sensor interrogation technique, the limit of detection was found to be 10 nM, with a linear dynamic range between 10 nM and 500 nM. In addition, the sensor responded to Hg{sup 2+} rather rapidly; majority of the signal change occurred in <20 min. Overall, the sensor retains all the characteristics of this class of sensors; it is reagentless, reusable, sensitive, specific and selective. This study also highlights the feasibility of using a MB-modified probe for real-time sensing of Hg{sup 2+}, which has not been previously reported. More importantly, the observed “switching” behavior in SWV and DPV is potentially generalizable and should be applicable to most sensors in this class of dynamics-based electrochemical biosensors.

  20. Differential-output B-dot and D-dot monitors for current and voltage measurements on a 20-MA, 3-MV pulsed-power accelerator

    Directory of Open Access Journals (Sweden)

    T. C. Wagoner

    2008-10-01

    signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR. The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday’s law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58  MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.

  1. Differential B-dot and D-dot monitors for current and voltage measurements on a 20-MA 3-MV pulsed-power accelerator.

    Energy Technology Data Exchange (ETDEWEB)

    Shoup, Roy Willlam (ITT Industries, Albuquerque, NM); Gilliland, Terrance Leo (Ktech Corporation, Albuquerque, NM); Lee, James R.; Speas, Christopher Shane; Kim, Alexandre A. (High Current Electronic Institute, Russian Academy of Sciences, Tomsk, Russia); Struve, Kenneth William; York, Mathew William; Leifeste, Gordon T.; Rochau, Gregory Alan; Sharpe, Arthur William; Stygar, William A.; Porter, John Larry Jr.; Wagoner, Tim C. (Ktech Corporation, Albuquerque, NM); Reynolds, Paul Gerard (Team Specialty Products Corporation, Albuquerque, NM); Slopek, Jeffrey Scott (Ktech Corporation, Albuquerque, NM); Moore, William B. S.; Dinwoodie, Thomas Albert (Ktech Corporation, Albuquerque, NM); Woodring, R. M. (Ktech Corporation, Albuquerque, NM); Broyles, Robin Scott (Ktech Corporation, Albuquerque, NM); Mills, Jerry Alan; Melville, J. A. (Prodyn Technologies Incorporated, Albuquerque, NM); Dudley, M. E. (Ktech Corporation, Albuquerque, NM); Androlewicz, K. E. (Ktech Corporation, Albuquerque, NM); Mourning, R. W. (Ktech Corporation, Albuquerque, NM); Moore, J. K. (Ktech Corporation, Albuquerque, NM); Serrano, Jason Dimitri (Ktech Corporation, Albuquerque, NM); Ives, H. C. (EG& G, Albuquerque, NM); Johnson, M. F. (Team Specialty Products Corporation, Albuquerque, NM); Peyton, B. P. (Ktech Corporation, Albuquerque, NM); Leeper, Ramon Joe; Savage, Mark Edward; Donovan, Guy Louis; Spielman, R. B. (Ktech Corporation, Albuquerque, NM); Seamen, Johann F.

    2007-12-01

    signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR). The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday's law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58 MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.

  2. Cranial electrotherapy stimulation and transcranial pulsed current stimulation: a computer based high-resolution modeling study.

    Science.gov (United States)

    Datta, Abhishek; Dmochowski, Jacek P; Guleyupoglu, Berkan; Bikson, Marom; Fregni, Felipe

    2013-01-15

    The field of non-invasive brain stimulation has developed significantly over the last two decades. Though two techniques of noninvasive brain stimulation--transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS)--are becoming established tools for research in neuroscience and for some clinical applications, related techniques that also show some promising clinical results have not been developed at the same pace. One of these related techniques is cranial electrotherapy stimulation (CES), a class of transcranial pulsed current stimulation (tPCS). In order to understand further the mechanisms of CES, we aimed to model CES using a magnetic resonance imaging (MRI)-derived finite element head model including cortical and also subcortical structures. Cortical electric field (current density) peak intensities and distributions were analyzed. We evaluated different electrode configurations of CES including in-ear and over-ear montages. Our results confirm that significant amounts of current pass the skull and reach cortical and subcortical structures. In addition, depending on the montage, induced currents at subcortical areas, such as midbrain, pons, thalamus and hypothalamus are of similar magnitude than that of cortical areas. Incremental variations of electrode position on the head surface also influence which cortical regions are modulated. The high-resolution modeling predictions suggest that details of electrode montage influence current flow through superficial and deep structures. Finally we present laptop based methods for tPCS dose design using dominant frequency and spherical models. These modeling predictions and tools are the first step to advance rational and optimized use of tPCS and CES.

  3. Analysis of Current Redistribution in a CICC under Transient Heat Pulses

    CERN Document Server

    Bottura, L; Marinucci, C

    2004-01-01

    We have performed experiments and simulations of the current distribution process in a CICC with the aim to understand better the coupled thermal, hydraulic and electric process that leads to a stable or unstable transient cable behaviour. The cable, wound from 128 Nb3Sn and pure copper strands, has been tested in the SULTAN facility. A resistive heater, glued on the jacket of the conductor, has been used to start the transient, and the response has been monitored with arrays of Hall plates. In this paper we report the results of simulations, especially the computed Hall signals, and compare them to the experimental data. Based on the experimental results and their interpretation we postulate that large temperature gradients must develop in the helium stream in the cable cross sections during the transient heat pulse.

  4. Microstructure Analysis of HPb59-1 Brass Induced by High Current Pulsed Electron Beam

    Science.gov (United States)

    Lyu, Jike; Gao, Bo; Hu, Liang; Lu, Shuaidan; Tu, Ganfeng

    2016-08-01

    In this paper, the effects of high current pulsed electron beam (HCPEB) on the microstructure evolution of casting HPb59-1 (Cu 57.1 mass%, Pb 1.7 mass% and Zn balance) alloy were investigated. The results showed a "wavy" surface which was formed with Pb element existing in the forms of stacking block and microparticles on the top surface layer after treatment. Nanocrystalline structures including Pb grains and two phases (α and β) were formed on the top remelted layer and their sizes were all less than 100 nm. The disordered β phase was generated in the surface layer after HCPEB treatment, which is beneficial for the improvement of surface properties. Meanwhile, there was a large residual stress on the alloy surface, along with the appearance of microcracks, and the preferred orientations of grains also changed.

  5. Pulsed eddy current and ultrasonic data fusion applied to stress measurement

    Science.gov (United States)

    Habibalahi, A.; Safizadeh, M. S.

    2014-05-01

    Stress measurement and its variation are key problems in the operating performance of materials. Stress can affect the material properties and the life of components. There are several destructive and nondestructive techniques that are used to measure stress. However, no single nondestructive testing (NDT) technique or method is satisfactory to fully assess stress. This paper presents an NDT data fusion method to improve stress measurement. An aluminum alloy 2024 specimen subjected to stress simulation is nondestructively inspected using pulsed eddy current and ultrasonic techniques. Following these nondestructive examinations, the information gathered from these two NDT methods has been fused using a suitable fuzzy combination operator. The results obtained with these processes are presented in this paper and their efficiency is discussed. It is shown that the fusion of NDT data with a suitable fuzzy operator can be adequate to improve the reliability of stress measurements.

  6. Influence of sulfides on the tribological properties of composites produced by pulse electric current sintering

    Institute of Scientific and Technical Information of China (English)

    Seung Ho Kim

    2014-01-01

    Self-lubricating Al2O3-15wt%ZrO2 composites with sulfides, such as molybdenum disulfide (MoS2) and tungsten disulfide (WS2) serving as solid lubricants, were fabricated by using the pulse electric current sintering (PECS) technique. The coefficient of friction (COF) of the Al2O3-15wt%ZrO2 composite without/with sulfides was in the range of 0.37-0.48 and 0.27-0.49, respectively. As the amount of sul-fides increased, the COF and the wear rate decreased. The reduction in COF and wear rate of the sulfide-containing composite is caused by a reduction in shear stresses between the specimen and the tribological medium due to the formation of a lubricating film resulting from the lamellar structure of sulfides located on the worn surface.

  7. 脉冲涡流测厚技术%Thickness Measurement Technique by Pulsed Eddy Current

    Institute of Scientific and Technical Information of China (English)

    吴鑫; 李方奇; 石坤; 谢基龙; 李浩

    2009-01-01

    脉冲涡流检测技术具有频谱宽、信号穿透能力强以及精确度好等优点.对脉冲涡流测厚技术进行了仿真,即针对脉冲涡流测厚系统,建立了有限元分析模型,仿真分析了检测线圈上的电压的衰减规律,得到了检测线圈上的电压随被测体厚度的变化规律,确定了两者之间的定量关系.分析了提离距离、检测线圈参数和脉冲涡流频率对检测结果的影响.该研究为将来进行脉冲涡流测厚仪的研制提供了理论依据和数学模型.%Pulsed eddy current technique had quite a few advantages such as wide spectrum, strong penetration,high accuracy. The experiment was carried out to study the metal thickness measurement of PEC, and a finite element model for the system of the metal thickness measurement of PEC was established. Based on the finite element model established, this thesis analyzed the attenuation law of the voltage in receiving coil By changing the thickness of tested bodies, the relationship between the voltage of receiving coil and the thickness of the testedbodies was analyzed, and also the factors that affected the measuring results such as lift-off distance, parameters of testing coil and frequency of pulsed eddy current were analyzed in detail It provided a theoretical basis and mathematical models for the future development of the PEC gage.

  8. Outlook for the use of microsecond plasma opening switches to generate high-power nanosecond current pulses

    Science.gov (United States)

    Dolgachev, G. I.; Maslennikov, D. D.; Ushakov, A. G.

    2006-12-01

    An analysis is made of the current break process in microsecond plasma opening switches and their possible application in high-current generators. Necessary conditions are determined for generating megavolt pulses in the erosion mode of a plasma opening switch with the gap insulated by an external magnetic field. Under these conditions, efficient sharpening of high-power submegampere current pulses can be achieved. The possibility of using plasma opening switches operating at voltages of 5 6 MV to generate X-ray and gamma emission is discussed. The main operating and design parameters of a six-module plasma opening switch with a current pulse amplitude of 3.7 MA and voltage of 4 6 MV for use in the MOL generator, which is the prototype of one of the 24 modules of the projected Baikal multimegajoule generator, are estimated by using the available scalings.

  9. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  10. Electrodeposition and characterization of Ni-ZrO2 nanocomposites by direct and pulse current methods.

    Science.gov (United States)

    Kumar, K Arunsunai; Mohan, P; Kalaignan, G Paruthimal; Muralidharan, V S

    2012-11-01

    Direct Current (DC) and Pulse current (PC) methods were used to get nanocrystalline Ni-ZrO2 composites from tri-ammonium citrate bath. In the electrocomposite formation, the ZrO2 particles were transported to the surface by mechanical action and got entrapped in the nickel matrix. Incorporation of ZrO2 in the nickel matrix was found to increase with current densities when DC was employed. Beyond 2 A/dm2, their incorporation became saturated when PC was used. PC method offered better electrocomposites than DC method producing finer grains and uniform surface. Scanning electron micrographs (SEM) reveals that smaller grains and uniform distribution of Zirconia particles in the nickel matrix. The increased hardness of Ni-ZrO2 electrocomposite coatings is due to incorporation of ZrO2 particles in the nickel matrix and also changes in grain size. Incorporation of ZrO2 particles in Ni-matrix favoured the enhanced microhardness and corrosion resistance of the deposit.

  11. Implementations of artificial neural networks using current-mode pulse width modulation technique.

    Science.gov (United States)

    El-Masry, E I; Yang, H K; Yakout, M A

    1997-01-01

    The use of a current-mode pulse width modulation (CM-PWM) technique to implement analog artificial neural networks (ANNs) is presented. This technique can be used to efficiently implement the weighted summation operation (WSO) that are required in the realization of a general ANN. The sigmoidal transformation is inherently performed by the nonlinear transconductance amplifier, which is a key component in the current integrator used in the realization of WSO. The CM-PWM implementation results in a minimum silicon area, and therefore is suitable for very large scale neural systems. Other pronounced features of the CM-PWM implementation are its easy programmability, electronically adjustable gains of neurons, and modular structures. In this paper, all the current-mode CMOS circuits (building blocks) required for the realization of CM-PWM ANNs are presented and simulated. Four modules for modular design of ANNs are introduced. Also, it is shown that the CM-PWM technique is an efficient method for implementing discrete-time cellular neural networks (DT-CNNs). Two application examples are given: a winner-take-all circuit and a connected component detector.

  12. Transient-spatial pattern mining of eddy current pulsed thermography using wavelet transform

    Science.gov (United States)

    Yang, Hailong; Gao, Bin; Tian, Guiyun; Ren, Wenwei; Woo, Wai Lok

    2014-07-01

    Eddy current pulsed thermography(ECPT) is an emerging Non-destructive testing and evaluation(NDT & E) technique, which uses hybrid eddy current and thermography NDT & E techniques that enhances the detectability from their compensation. Currently, this technique is limited by the manual selection of proper contrast frames and the issue of improving the efficiency of defect detection of complex structure samples remains a challenge. In order to select a specific frame from transient thermal image sequences to maximize the contrast of thermal variation and defect pattern from complex structure samples, an energy driven approach to compute the coefficient energy of wavelet transform is proposed which has the potential of automatically selecting both optimal transient frame and spatial scale for defect detection using ECPT. According to analysis of the variation of different frequency component and the comparison study of the detection performance of different scale and wavelets, the frame at the end of heating phase is automatically selected as an optimal transient frame for defect detection. In addition, the detection capabilities of the complex structure samples can be enhanced through proper spatial scale and wavelet selection. The proposed method has successfully been applied to low speed impact damage detection of carbon fibre reinforced polymer(CFRP) composite as well as providing the guidance to improve the detectability of ECPT technique.

  13. Effect of pulse current on acidification and removal of Cu, Cd, and As during suspended electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian Ran; Ottosen, Lisbeth M.; Jensen, Pernille Erland

    2013-01-01

    , predominately working under overlimiting current density conditions. Soil 1 was sampled from a pile of excavated soil at a site with mixed industrial pollution (Cu and Cd), and soil 2 was sampled from the top layer of a wood preservation site (Cu and As). Results showed that pulse current improved...

  14. Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

    Science.gov (United States)

    Gomez, Carla Cristina Souza; Servidoni, Maria de Fatima; Marson, Fernando Augusto de Lima; Canavezi, Paulo Jose Coelho; Vinagre, Adriana Mendes; Costa, Eduardo Tavares; Ribeiro, Antonio Fernando; Ribeiro, Maria Angela Gonçalves de Oliveira; Toro, Adyleia Aparecida Dalbo Contrera; Pavan, Celia Regina; Rondon, Michelle Vivine Sá Dos Santos; Lorena, Sonia Leticia Silva; Vieria, Francisco Ubaldi; Ribeiro, Jose Dirceu

    2014-12-13

    The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal

  15. Application of Streaming Effect and Joule Heating Effect of Pulse Current in Crack Healing of Metal Materials

    Directory of Open Access Journals (Sweden)

    Jian Chu

    2017-06-01

    Full Text Available Remanufacture engineering is an emerging industry that saves resources as well as protects the environment. However, cracks on remanufactured components can result in serious trouble. Therefore, in order to avoid unnecessary waste of resources and energy, these cracks should be repaired radically in order to ensure the smooth progressing of the remanufacturing process. Consequently, the crack healing technique of metal materials is very important in the field of remanufacturing. In this study, the U-shape vane stainless steel of a centrifugal compressor which had cracks was processed by pulse current using a high pulse current discharge device, and the influence of the streaming effect and Joule heating effect of pulse current on the crack healing of metal materials was studied, aiming to provide references for the better application of this technology in the remanufacturing field in the future.

  16. Pulsed remote field eddy current technique applied to non-magnetic flat conductive plates

    Science.gov (United States)

    Yang, Binfeng; Zhang, Hui; Zhang, Chao; Zhang, Zhanbin

    2013-12-01

    Non-magnetic metal plates are widely used in aviation and industrial applications. The detection of cracks in thick plate structures, such as multilayered structures of aircraft fuselage, has been challenging in nondestructive evaluation societies. The remote field eddy current (RFEC) technique has shown advantages of deep penetration and high sensitivity to deeply buried anomalies. However, the RFEC technique is mainly used to evaluate ferromagnetic tubes. There are many problems that should be fixed before the expansion and application of this technique for the inspection of non-magnetic conductive plates. In this article, the pulsed remote field eddy current (PRFEC) technique for the detection of defects in non-magnetic conducting plates was investigated. First, the principle of the PRFEC technique was analysed, followed by the analysis of the differences between the detection of defects in ferromagnetic and non-magnetic plain structures. Three different models of the PRFEC probe were simulated using ANSYS. The location of the transition zone, defect detection sensitivity and the ability to detect defects in thick plates using three probes were analysed and compared. The simulation results showed that the probe with a ferrite core had the highest detecting ability. The conclusions derived from the simulation study were also validated by conducting experiments.

  17. Reconstruction of stress corrosion cracks using signals of pulsed eddy current testing

    Science.gov (United States)

    Wang, Li; Xie, Shejuan; Chen, Zhenmao; Li, Yong; Wang, Xiaowei; Takagi, Toshiyuki

    2013-06-01

    A scheme to apply signals of pulsed eddy current testing (PECT) to reconstruct a deep stress corrosion crack (SCC) is proposed on the basis of a multi-layer and multi-frequency reconstruction strategy. First, a numerical method is introduced to extract conventional eddy current testing (ECT) signals of different frequencies from the PECT responses at different scanning points, which are necessary for multi-frequency ECT inversion. Second, the conventional fast forward solver for ECT signal simulation is upgraded to calculate the single-frequency pickup signal of a magnetic field by introducing a strategy that employs a tiny search coil. Using the multiple-frequency ECT signals and the upgraded fast signal simulator, we reconstructed the shape profiles and conductivity of an SCC at different depths layer-by-layer with a hybrid inversion scheme of the conjugate gradient and particle swarm optimisation. Several modelled SCCs of rectangular or stepwise shape in an SUS304 plate are reconstructed from simulated PECT signals with artificial noise. The reconstruction results show better precision in crack depth than the conventional ECT inversion method, which demonstrates the validity and efficiency of the proposed PECT inversion scheme.

  18. Pulsed direct current electric fields enhance osteogenesis in adipose-derived stromal cells.

    Science.gov (United States)

    Hammerick, Kyle E; James, Aaron W; Huang, Zubin; Prinz, Fritz B; Longaker, Michael T

    2010-03-01

    Adipose-derived stromal cells (ASCs) constitute a promising source of cells for regenerative medicine applications. Previous studies of osteogenic potential in ASCs have focused on chemicals, growth factors, and mechanical stimuli. Citing the demonstrated role electric fields play in enhancing healing in bone fractures and defects, we investigated the ability of pulsed direct current electric fields to drive osteogenic differentiation in mouse ASCs. Employing 50 Hz direct current electric fields in concert with and without osteogenic factors, we demonstrated increased early osteoblast-specific markers. We were also able to establish that commonly reported artifacts of electric field stimulation are not the primary mediators of the observed effects. The electric fields caused marked changes in the cytoskeleton. We used atomic force microscopy-based force spectroscopy to record an increase in the cytoskeletal tension after treatment with electric fields. We abolished the increased cytoskeletal stresses with the rho-associated protein kinase inhibitor, Y27632, and did not see any decrease in osteogenic gene expression, suggesting that the pro-osteogenic effects of the electric fields are not transduced via cytoskeletal tension. Electric fields may show promise as candidate enhancers of osteogenesis of ASCs and may be incorporated into cell-based strategies for skeletal regeneration.

  19. Analysis of pulsed eddy current data using regression models for steam generator tube support structure inspection

    Science.gov (United States)

    Buck, J. A.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2016-02-01

    Nuclear steam generators (SGs) are a critical component for ensuring safe and efficient operation of a reactor. Life management strategies are implemented in which SG tubes are regularly inspected by conventional eddy current testing (ECT) and ultrasonic testing (UT) technologies to size flaws, and safe operating life of SGs is predicted based on growth models. ECT, the more commonly used technique, due to the rapidity with which full SG tube wall inspection can be performed, is challenged when inspecting ferromagnetic support structure materials in the presence of magnetite sludge and multiple overlapping degradation modes. In this work, an emerging inspection method, pulsed eddy current (PEC), is being investigated to address some of these particular inspection conditions. Time-domain signals were collected by an 8 coil array PEC probe in which ferromagnetic drilled support hole diameter, depth of rectangular tube frets and 2D tube off-centering were varied. Data sets were analyzed with a modified principal components analysis (MPCA) to extract dominant signal features. Multiple linear regression models were applied to MPCA scores to size hole diameter as well as size rectangular outer diameter tube frets. Models were improved through exploratory factor analysis, which was applied to MPCA scores to refine selection for regression models inputs by removing nonessential information.

  20. Enhancing pulsed eddy current for inspection of P-3 Orion lap-joint structures

    Science.gov (United States)

    Butt, D. M.; Underhill, P. R.; Krause, T. W.

    2016-02-01

    During flight, aircraft are subjected to cyclic loading. In the Lockheed P-3 Orion airframe, this cyclic loading can lead to development of fatigue cracks at steel fastener locations in the top and second layers of aluminum wing skin lap-joints. An inspection method that is capable of detecting these cracks, without fastener removal, is desirable as this can minimize aircraft downtime, while subsequently reducing the risk of collateral damage. The ability to detect second layer cracks has been demonstrated using a Pulsed Eddy Current (PEC) probe design that utilizes the ferrous fastener as a flux conduit. This allows for deeper penetration of flux into the lap-joint second layer and consequently, sensitivity to the presence of cracks. Differential pick-up coil pairs are used to sense the eddy current response due to the presence of a crack. The differential signal obtained from pick-up coils on opposing sides of the fastener is analyzed using a Modified Principal Components Analysis (MPCA). This is followed by a cluster analysis of the resulting MPCA scores to separate fastener locations with cracks from those without. Probe design features, data acquisition system parameters and signal post-processing can each have a strong impact on crack detection. Physical probe configurations and signal analysis processes, used to enhance the PEC system for detection of cracks in P-3 Orion lap-joint structures, are investigated and an enhanced probe design is identified.

  1. LPI: pulsed solenoid for positron focusing in LIL

    CERN Multimedia

    Photographic Service

    1993-01-01

    The solenoid for the initial focusing of the positrons emerging from the conversion target is mounted inside the vacuum, immediately after the target. Pulsed with a current of 6 kA for some 7 microseconds, it produces a longitudinal magnetic field of 1.5 T.

  2. Eddy current pulsed phase thermography considering volumetric induction heating for delamination evaluation in carbon fiber reinforced polymers

    Science.gov (United States)

    Yang, Ruizhen; He, Yunze

    2015-06-01

    Anisotropy and inhomogeneity of carbon fiber reinforced polymers (CFRPs) result in that many traditional non-destructive inspection techniques are inapplicable on the delamination evaluation. This letter introduces eddy current pulsed phase thermography (ECPPT) for CFRPs evaluation considering volumetric induction heating due to small electrical conductivity, abnormal thermal wave propagation, and Fourier analysis. The proposed methods were verified through experimental studies under transmission and reflection modes. Using ECPPT, the influence of the non-uniform heating effect and carbon fiber structures can be suppressed, and then delamination detectability can be improved dramatically over eddy current pulsed thermography.

  3. Pulsed Artificial Electrojet Generation

    Science.gov (United States)

    Papadopoulos, K.

    2008-12-01

    Traditional techniques for generating low frequency signals in the ULF/ELF range (.1-100 Hz) and rely on ground based Horizontal Electric Dipole (HED) antennas. It is, furthermore, well known that a Vertical Electric Dipole (VED) is by more than 50 dB more efficient than a HED with the same dipole current moment. However, the prohibitively long length of VED antennas in the ELF/ULF range coupled with voltage limitations due to corona discharge in the atmosphere make them totally impracticable. In this paper we discuss a novel concept, inspired by the physics of the equatorial electrojet, that allows for the conversion of a ground based HED to a VED in the E-region of the equatorial ionosphere with current moment comparable to the driving HED. The paper focuses in locations near the dip-equator, where the earth's magnetic is in predominantly in the horizontal direction. The horizontal electric field associated with a pulsed HED drives a large Hall current in the ionospheric E-region, resulting in a vertical current. It is shown that the pulsed vertical current in the altitude range 80-130 km, driven by a horizontal electric field of, approximately, .1 mV/m at 100 km altitude, is of the order of kA. This results in a pulsed VED larger than 106 A-m. Such a pulsed VED will drive ELF/ULF pulses with amplitude in excess of .1 nT at a lateral range larger than few hundred kilometers. This is by three orders of magnitude larger than the one expected by a HED with comparable current moment. The paper will conclude with the description of a sneak-through technique that allows for creating pulsed electric fields in the ionosphere much larger than expected from steady state oscillatory HED antennas.

  4. The break of shielding current at pulsed field magnetization of a superconducting annulus (experiment and model simulation)

    Science.gov (United States)

    Korotkov, V. S.; Krasnoperov, E. P.; Kartamyshev, A. A.

    2017-09-01

    During the pulsed field magnetization of a high-T c annulus in liquid nitrogen the shielding current drops abruptly, providing rapid penetration of the magnetic flux into the hole of the superconductor. After the break of current the trapped field in the hole is small and negative although the body of the annulus remains highly magnetized. In the present work the current breaking effect is investigated both experimentally and numerically. The influence of the pulse parameter on the shielding current evolution during the break is researched. A simple model for the qualitative description of this process is proposed. The model shows the development of heating localized on the inhomogeneity of the high-temperature superconductor annulus providing the formation of a high resistive channel with temperature near to T c. The appearance of this hot channel leads to the rapid reduction of the shielding current and presents a new scenario of flux jump at high temperature.

  5. Inspection of ferromagnetic support structures from within alloy 800 steam generator tubes using pulsed eddy current

    Science.gov (United States)

    Buck, Jeremy Andrew

    Nondestructive testing is a critical aspect of component lifetime management. Nuclear steam generator (SG) tubes are the thinnest barrier between irradiated primary heat transport system and the secondary heat transport system, whose components are not rated for large radiation fields. Conventional eddy current testing (ECT) and ultrasonic testing are currently employed for inspecting SG tubes, with the former doing most inspections due to speed and reliability based on an understanding of how flaws affect coil impedance parameters when conductors are subjected to harmonically induced currents. However, when multiple degradation modes are present simultaneously near ferromagnetic materials, such as tube fretting, support structure corrosion, and magnetite fouling, ECT reliability decreases. Pulsed eddy current (PEC), which induces transient eddy currents via square wave excitation, has been considered in this thesis to simultaneously examine SG tube and support structure conditions. An array probe consisting of a central driver, coaxial with the tube, and an array of 8 sensing coils, was used in this thesis to perform laboratory measurements. The probe was delivered from the inner diameter (ID) of the SG tube, where support hole diameter, tube frets, and 2D off-centering were varied. When considering two variables simultaneously, scores obtained from a modified principal components analysis (MPCA) were sufficient for parameter extraction. In the case of hole ID variation with two dimensional tube off-centering (three parameters), multiple linear regression (MLR) of the MPCA scores provided good estimates of parameters. However, once a fourth variable, outer diameter tube frets, was introduced, MLR proved insufficient. Artificial neural networks (ANNs) were investigated in order to perform pattern recognition on the MPCA scores to simultaneously extract the four measurement parameters from the data. All models throughout this thesis were created and validated using

  6. Transient Response of Arc Temperature and Iron Vapor Concentration Affected by Current Frequency with Iron Vapor in Pulsed Arc

    Science.gov (United States)

    Tanaka, Tatsuro; Maeda, Yoshifumi; Yamamoto, Shinji; Iwao, Toru

    2016-10-01

    TIG arc welding is chemically a joining technology with melting the metallic material and it can be high quality. However, this welding should not be used in high current to prevent cathode melting. Thus, the heat transfer is poor. Therefore, the deep penetration cannot be obtained and the weld defect sometimes occurs. The pulsed arc welding has been used for the improvement of this defect. The pulsed arc welding can control the heat flux to anode. The convention and driving force in the weld pool are caused by the arc. Therefore, it is important to grasp the distribution of arc temperature. The metal vapor generate from the anode in welding. In addition, the pulsed current increased or decreased periodically. Therefore, the arc is affected by such as a current value and current frequency, the current rate of increment and the metal vapor. In this paper, the transient response of arc temperature and the iron vapor concentration affected by the current frequency with iron vapor in pulsed arc was elucidated by the EMTF (ElectroMagnetic Thermal Fluid) simulation. As a result, the arc temperature and the iron vapor were transient response as the current frequency increase. Thus, the temperature and the electrical conductivity decreased. Therefore, the electrical field increased in order to maintain the current continuity. The current density and electromagnetic force increased at the axial center. In addition, the electronic flow component of the heat flux increased at the axial center because the current density increased. However, the heat conduction component of the heat flux decreased.

  7. Design of shielded encircling send-receive type pulsed eddy current probe using numerical analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil [Dept. of Electircal Engineeirng, Kunsan National University, Kunsan (Korea, Republic of)

    2013-12-15

    An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

  8. Nano-structured morphological features of pulsed direct current magnetron sputtered Mo films for photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Karthikeyan, Sreejith, E-mail: s.karthikeyan@edu.salford.ac.uk; Hill, Arthur E.; Pilkington, Richard D.

    2011-10-31

    Historically, molybdenum thin films have been used as the back contact for Cu(In,Ga)Se{sub 2} based solar cells and as such the properties of these layers play an important role in the overall cell structure. This paper describes the production of molybdenum films using pulsed d.c. magnetron sputtering from compressed molybdenum powder targets. The films were deposited at different substrate temperatures under constant power and constant current modes, and analysed using X-ray diffraction, scanning electron microscopy, atomic force microscopy and four point resistance probe. Mechanical strain and resistivity were found to decrease with substrate temperature together with a shift in the (110) crystallographic plane towards higher diffraction angles. All films were well adhered to the glass substrates irrespective of their high tensile strain. Surface morphology analysis revealed the presence of nano-structured stress relief patterns which can enhance the nucleation sites for subsequent CuInSe{sub 2} deposition. A high-resolution cross sectional image showed the columnar growth of the films. Surface roughness analysis revealed that roughness increased with increase in substrate temperature.

  9. Pulsed counter-current ultrasound-assisted extraction and characterization of polysaccharides from Boletus edulis.

    Science.gov (United States)

    You, Qinghong; Yin, Xiulian; Ji, Chaowen

    2014-01-30

    Four methods for extracting polysaccharides from Boletus edulis, namely, hot-water extraction, ultrasonic clearer extraction, static probe ultrasonic extraction, and pulsed counter-current probe ultrasonic extraction (CCPUE), were studied. Results showed that CCPUE has the highest extraction efficiency among the methods studied. Under optimal CCPUE conditions, a B. edulis polysaccharide (BEP) yield of 8.21% was obtained. Three purified fractions, BEP-I, BEP-II, and BEP-III, were obtained through sequential purification by DEAE-52 and Sephadex G-75 chromatography. The average molecular weights of BEP-I, BEP-II, and BEP-III were 10,278, 23,761, and 42,736 Da, respectively. The polysaccharides were mainly composed of xylose, mannose, galactose, and glucose; of these, mannose contents were the highest. The antioxidant activities of the BEPs were further investigated by measurement of their ability to scavenge DPPH and hydroxyl radicals as well as their reducing power. The results indicated that the BEPs have good antioxidant activity.

  10. Application of Hilbert-Huang transform for defect recognition in pulsed eddy current testing

    Science.gov (United States)

    Liu, Baoling; Huang, Pingjie; Hou, Dibo; Chen, Xiao; Zhang, Guangxin

    2015-07-01

    Defect recognition plays an important role in the structure integrity and health monitor of in-service equipment. However, it is difficult to recognise deep-layer defect or small-size defect in conductive structure during pulsed eddy current (PEC) testing. Aiming at the issue, this article proposes a method based on Hilbert-Huang transform which consists of two modules: data processing and defect recognition. In the data processing module, the PEC response signal is decomposed into a few of intrinsic mode functions (IMFs) using ensemble empirical mode decomposition method. The IMFs whose variance contribution rates are bigger than 1% are chosen to reconstruct signal in order to remove noise. In the defect recognition module, the features based on specific frequency components of marginal spectrum (MS) of the reconstructed signals are extracted to discriminate those defects in surface and subsurface. Furthermore, the normalisation MS energy ratio is proposed to quantify defects which cannot be distinguished using peak value in time domain. Experiments show that the proposed method can achieve better de-noising effect and defect evaluation, which contributes to the recognition of those complicated defects such as deep-layered and small-sized defect.

  11. Investigation of pulsed eddy current probes for detection of defects in riveted structures

    Science.gov (United States)

    Yang, Binfeng; Zhang, Hui; Kang, Zhibin; Wang, Xiaofeng

    2013-09-01

    The fatigue crack is the threat to integrity and safety of fuselage lap-joints. Quantification of fatigue cracks by designing and utilisation of an optimised electromagnetic nondestructive evaluation probe can insure the flight safety of aircrafts. In this paper, pulsed eddy current (PEC) for detection and characterisation of fatigue cracks is investigated. The principle of PEC is analysed first, from which four different models of PEC probes are simulated in ANSYS. The signal features, namely zero-crossing time, zero-crossing frequency and peak value are extracted from the time and frequency domains in an effort to qualitatively compare the crack detectability of the four models. The sensitivities of the different probes to cracks are analysed quantitatively. The difference in detectability among the probes is investigated based on the working principle. Simulation results show that the probe consisting of two horizontal detecting coils along with a magnetic field shield focusing the flux has the highest detectability. The conclusions derived from the simulation study are also validated by experiments.

  12. Design of encircling send-receive type pulsed eddy current probe

    Science.gov (United States)

    Shin, Young-Kil

    2014-02-01

    An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in the tube inspection. When bare receive coils, which are located away from the exciter, are used, the peak time of the signal does not change although the distance from the exciter increases. This is because the magnetic fields from exciter coil arrive directly at the receive coil without passing through the tube. Therefore, in this work, both exciter and sensor coils are shielded to reduce the influence of direct fields from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe shows the corresponding increase of peak time as the sensor distance increases. Ferrite and carbon steel shields are compared and found that the ferrite shielding results in slightly stronger peak value and quicker peak time than the carbon steel shielding. Sensitivity of peak value to defect depth variation is also investigated and found that the normalized peak value is more sensitive when the sensor is located closer to the exciter for aluminum tube. In the case of magnetic tube, however, all the characteristics are opposite to those obtained from nonmagnetic aluminum tube.

  13. Validation of a pulsed eddy current system for measuring wall thinning through insulation

    Science.gov (United States)

    Brett, Colin R.; de Raad, Jan A.

    1996-11-01

    There have been several failures in power plant feedwater piping systems due to wall thinning caused by flow- accelerated corrosion of the inner surface. Detection of wastage in susceptible pipes is costly as traditional NDE methods such as ultrasonic testing entail removal and reinstallation of insulation over many meters of pipework. Radiography is one solution to this problem, but it is slow to apply and requires careful attention to safety. The RTD Incotest system uses pulsed eddy current technology to measure pipewall thickness through insulation and external cladding. The technology has been licensed from Arco, Inc., who originally developed the technique for large diameter pipelines and storage tanks where the area interrogated was made deliberately large. This paper describes an optimized Incotest systems which can detect and measure internal or external wall wastage which is more localized and typical of flow-accelerated corrosion. Improvements have also been made to the inspection and data acquisition in order to increase the inspection rate and overall productivity. Ultimately the performance of the optimized Incotest system has been verified on samples which contain artificial and real corrosion.

  14. Synthesis and characterization of silver-carbon nanoparticles produced by high-current pulsed arc

    Energy Technology Data Exchange (ETDEWEB)

    Maya, F., E-mail: fermr@correo.unam.m [Departamento de Microscopia Electronica, Centro de Investigacion en Materiales Avanzados, Miguel de Cervantes 120, Chihuahua, Chih., CP 3110 (Mexico); Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, 04510 (Mexico); Muhl, S.; Pena, O. [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, 04510 (Mexico); Miki-Yoshida, M. [Departamento de Microscopia Electronica, Centro de Investigacion en Materiales Avanzados, Miguel de Cervantes 120, Chihuahua, Chih., CP 3110 (Mexico)

    2009-12-31

    In this paper, we report the formation of silver-carbon encapsulated metal nanoparticles (EMN's) using a high-current pulsed arc system in an argon atmosphere. The deposits were studied by Optical Extinction Spectroscopy (OES), X-ray diffraction (XRD) and Transmission Electron Microscopy (TEM); the chemical analysis of the deposits was performed using Energy Dispersion X-ray spectroscopy (EDX). Using the total nanoparticle diameter, the bulk crystalline density of silver and an estimate amorphous carbon (a-C) density we have calculated the size of the silver nucleus and the thickness of the a-C coating as a function of the argon gas pressure. The OES spectra of the EMN's exhibited two peaks characteristic of the Surface Plasmon Resonance (SPR) of elongated/very close silver nanoparticles; a subsequent thermal annealing strongly increased the SPR peaks. The double peak SPR spectra were modeled using calculations based on the existence of silver nanoparticles in the form of prolate spheroids. The main advantage of our preparation method is that the metal nanoparticles are encapsulated in a-C from the beginning and this layer acts as an efficient chemical barrier.

  15. Predictive study of the poloidal field coil insert behaviour under pulsed current tests

    Science.gov (United States)

    Lacroix, B.; Ciazynski, D.; Duchateau, J. L.; Nicollet, S.; Pauty, N.

    2008-02-01

    Within the ITER Poloidal Field conductor design validation, the Poloidal Field Conductor Insert (PFCI) has been manufactured and will be tested in the Central Solenoid Model Coil (CSMC) facility at JAEA Naka (Japan). In this test facility, the PFCI can be tested under ITER-relevant operating conditions, the field produced by the CSMC being varied to simulate the real situation of the PF coils in ITER. Predictive analyses have been performed in order to study the electromagnetic and thermal-hydraulic behaviour of the PFCI, under two scenarios proposed for pulsed current tests. During these scenarios, simulations have been performed with the THEA code, in which classical formulas for the AC losses in a cable have been introduced. The study focuses on the lower part of the winding, which is a 44 m long conductor including a joint. It covers the sample thermal-hydraulic behaviour with particular emphasis on the losses. Due to the overcompaction in the joint area, the total energy dissipated during a scenario can be equivalent in the joint and in the conductor, in spite of the reduced length of the joint (0.45 m). This particular point is discussed and has led to the analysis of the temperature margin in the joint.

  16. Corrosion resistant Zn–Co alloy coatings deposited using saw-tooth current pulse

    Indian Academy of Sciences (India)

    S Yogesha; A Chitharanjan Hegde

    2011-12-01

    Micro/nanostructured multilayer coatings of Zn–Co alloy were developed periodically on mild steel from acid chloride bath. Composition modulated multilayer alloy (CMMA) coatings, having gradual change in composition (in each layer) were developed galvanostatically using saw-tooth pulses through single bath technique (SBT). CMMA coatings were developed under different conditions of cyclic cathode current densities (CCCDs) and number of layers, and their corrosion resistances were evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) method. Optimal configuration, represented as (Zn–Co)2.0/4.0/300 was found to exhibit ∼ 89 times better corrosion resistance compared to monolithic (Zn–Co)3.0 alloy deposited for same time, from same bath. The better corrosion resistance of CMMA coatings was attributed to changed interfacial dielectric properties, evidenced by dielectric spectroscopy. Improved corrosion resistance was attributed to formation of -type semiconductor film at the interface, supported by the Mott–Schottky plot. Further, the formation of multilayer and corrosion mechanism was analysed using scanning electron microscopy (SEM).

  17. Initiation of ignition by the action of a high-current pulsed discharge on a gas

    NARCIS (Netherlands)

    Starikovskii, AY

    2003-01-01

    The possibility of nonthermal initiation of chemical reactions by a uniform pulsed nanosecond discharge is demonstrated. Dependences of variation of the ignition delay on initial conditions are obtained. It is shown that the main role in combustion initiation under conditions of a pulsed gas dischar

  18. Halo Evolution of Hypereutectic Al-17.5Si Alloy Treated with High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    L. Hu

    2015-01-01

    Full Text Available Halo evolution of an Al-17.5Si alloy surface after treatment with increasing pulse numbers of a high-current pulsed electron beam (HCPEB was investigated. A halo is a ring microstructure resembling a bull’s eye. SEM results indicate that the nanocrystallization of halo induced by HCPEB treatment leads to gradual diffusion of the Si phase. Multiple pulses numbers cause the Si phase to be significantly refined and uniformly distributed. In addition, nanosilicon particles with a grain size of 30~100 nm were formed after HCPEB treatment, as shown by TEM observation. XRD results indicate that Si diffraction peaks broadened after HCPEB treatment. The microhardness tests demonstrate that the microhardness at the midpoint from the halo edge to center decreased sharply from 9770.7 MPa at 5 pulses to 2664.14 MPa at 25 pulses. The relative wear resistance of a 15-pulse sample is effectively improved by a factor of 6.5, exhibiting optimal wear resistance.

  19. Evaluation of machine learning tools for inspection of steam generator tube structures using pulsed eddy current

    Science.gov (United States)

    Buck, J. A.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2017-02-01

    Degradation of nuclear steam generator (SG) tubes and support structures can result in a loss of reactor efficiency. Regular in-service inspection, by conventional eddy current testing (ECT), permits detection of cracks, measurement of wall loss, and identification of other SG tube degradation modes. However, ECT is challenged by overlapping degradation modes such as might occur for SG tube fretting accompanied by tube off-set within a corroding ferromagnetic support structure. Pulsed eddy current (PEC) is an emerging technology examined here for inspection of Alloy-800 SG tubes and associated carbon steel drilled support structures. Support structure hole size was varied to simulate uniform corrosion, while SG tube was off-set relative to hole axis. PEC measurements were performed using a single driver with an 8 pick-up coil configuration in the presence of flat-bottom rectangular frets as an overlapping degradation mode. A modified principal component analysis (MPCA) was performed on the time-voltage data in order to reduce data dimensionality. The MPCA scores were then used to train a support vector machine (SVM) that simultaneously targeted four independent parameters associated with; support structure hole size, tube off-centering in two dimensions and fret depth. The support vector machine was trained, tested, and validated on experimental data. Results were compared with a previously developed artificial neural network (ANN) trained on the same data. Estimates of tube position showed comparable results between the two machine learning tools. However, the ANN produced better estimates of hole inner diameter and fret depth. The better results from ANN analysis was attributed to challenges associated with the SVM when non-constant variance is present in the data.

  20. EFFECTS OF HIGH-DENSITY CURRENT PULSES ON WORKHARDENING BEHAVIORS OF AUSTENITE STAINLESS STEELIN WIRE-DRAWING DEFORMATION

    Institute of Scientific and Technical Information of China (English)

    K.F. Yao; P. Yu; J. Wang; W. Fang; M.X. Zheng

    2001-01-01

    The influence of high-density palsing current on the work-hardening behavior of H0Cr17Ni6Mn3 and 1Cr18Ni9 stainless steels in wire-drawing deformation processes has been studied. It was found that the drawing stress and the work-hardening rate of wires were significantly reduced by applying current pulses in drawing process. The work-hardening behavior of the multi-courses drawing deformation can be well described by Hollomon formula σ = kεn. With the application of current pulses in drawing deformation, the work-hardening exponents of H0Cr17Ni6Mn3 steel wires and 1Cr18Ni9 stainless steel wires were reduced by 33% and 45%, respectively, and their work-hardening coefficients were reduced by 41% and 47%, respectively. It was also found that the work-hardening coefficient of wires was reduced with the increment of the frequency of current pulses, while the work-hardening exponents of both steels were insensitive to the pulsing frequency.``

  1. An EIS alternative for impedance measurement of a high temperature PEM fuel cell stack based on current pulse injection

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Araya, Samuel Simon; Sahlin, Simon Lennart

    2017-01-01

    In this paper a method for estimating the fuel cell impedance is presented, namely the current pulse injection (CPI) method, which is well suited for online implementation. This method estimates the fuel cell impedance and unlike electrochemical impedance spectroscopy (EIS), it is simple to imple...

  2. Can the use of pulsed direct current induce oscillation in the applied pressure during spark plasma sintering?

    Directory of Open Access Journals (Sweden)

    David Salamon, Mirva Eriksson, Mats Nygren and Zhijian Shen

    2012-01-01

    Full Text Available The spark plasma sintering (SPS process is known for its rapid densification of metals and ceramics. The mechanism behind this rapid densification has been discussed during the last few decades and is yet uncertain. During our SPS experiments we noticed oscillations in the applied pressure, related to a change in electric current. In this study, we investigated the effect of pulsed electrical current on the applied mechanical pressure and related changes in temperature. We eliminated the effect of sample shrinkage in the SPS setup and used a transparent quartz die allowing direct observation of the sample. We found that the use of pulsed direct electric current in our apparatus induces pressure oscillations with the amplitude depending on the current density. While sintering Ti samples we observed temperature oscillations resulting from pressure oscillations, which we attribute to magnetic forces generated within the SPS apparatus. The described current–pressure–temperature relations might increase understanding of the SPS process.

  3. Effect of direct current and pulse plating on the EDM performance of copper-zirconium diboride composites

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Direct current and pulse plating of copper-zirconium diboride (ZrB2) composites were studied and the effects of current density (DC) and pulse duty cycle (PC) on the EDM performance of the composites were investigated. With increasing current density, the effect of grain refinement on the electro-discharge machining (EDM) performance of the composites compensates that of the decrease of ZrB2 content in the composites, which improves the spark-resistance of the material. Under the same average current density and other experiment conditions, a lower duty cycle yields better EDM performance probably because more ZrB2 particles are incorporated in the composites in this condition. However, at a still lower duty cycle (10%), the particle agglomeration and the microcracks of the copper matrix occur, which considerably deteriorate the spark-resistance of the composites.

  4. Beam tests on the 4-kA, 1. 5-MeV injector for FXR

    Energy Technology Data Exchange (ETDEWEB)

    Kulke, B.; Kihara, R.; Ravenscroft, D.; Scarpetti, R.; Vogtlin, G.

    1981-01-01

    The new flash x-ray machine (FXR) at Lawrence Livermore National Laboratory is scheduled for completion in late 1981. This is a 54 module, linear induction accelertor, designed to deliver 500 Roentgen at 1 m as bremsstrahlung from a 20 MeV, 4 kA, 60 ns pulsed electron beam. The 9 cm diameter, cold-cathode electron source generates a 15 kA emitted beam at 1.5 MeV, and collimation is being used to reduce the transmitted current to 3.5 kA, with an emittance of 70 mr-cm. The collimated beam diameter is 4 cm. Six ferrite-loaded cavities are used in tandem to energize the injector. The high voltage performance of the injector cavities and other pulsed-power conditioning elements was tested earlier in a series of 10/sup 5/ shots at 400 kV per cavity. An overview of the injector design and of the beam test results is given.

  5. Generation of nanosecond S band microwave pulses based on superradiance

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, N.S.; Zotova, I.V.; Rozental, R.M. [Russian Academy of Science, Institute of Applied Physics, Nizhny Novgorod (RU)] [and others

    2002-06-01

    Modeling carried out demonstrates possibility of generation of gigawatt power level S band microwave pulse with duration of several nanoseconds using superradiation of short electron beam moving along slow-wave periodical structure. A 10 ns / 500 keV / 5 kA accelerator of Kanazawa University can be used in such experiments. It is shown that significant increasing peak power can be obtained by optimization of voltage and current pulses waveforms. Required increasing of electron energy and current by the end of electron pulse can be achieved by using self-acceleration of a short beam passing through a system of passive cavities. (author)

  6. Influence of current density on surface morphology and properties of pulse plated tin films from citrate electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Ashutosh; Bhattacharya, Sumit; Das, Siddhartha; Das, Karabi, E-mail: karabi@metal.iitkgp.ernet.in

    2014-01-30

    Bulk polycrystalline tin films have been processed by pulse electrodeposition technique from a simple solution containing triammonium citrate and stannous chloride. The cathodic investigations have been carried out by galvanostatic methods. As deposited samples are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). XRD analysis of the deposited films shows microcrystalline grains having β-Sn form. The surface morphology is very rough at lower current density, but becomes smooth at higher current density, and exhibits pyramid type morphology at all the current densities. The effect of current density on microhardness, melting behavior, and electrical resistivity are also reported here.

  7. First-principles simulations for excitation of currents in linear carbon chains under femtosecond laser pulse irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Su, Gaoshi [School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081 (China); Jiang, Lan, E-mail: jianglan@bit.edu.cn [Laser Micro/Nano Fabrication Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081 (China); Wang, Feng [School of Physics, Beijing Institute of Technology, Beijing 100081 (China); Qu, Liangti [Key Laboratory of Cluster Science, Ministry of Education, School of Chemistry, Beijing Institute of Technology, Beijing 100081 (China); Lu, Yongfeng [Department of Electrical Engineering, University of Nebraska–Lincoln, Lincoln, NE 68588-0511 (United States)

    2016-07-15

    We discuss the response of linear carbon chains to a femtosecond laser pulse. The influence of the chain structure on the excited currents was taken into account. The simulation results showed that excited currents were reversible when laser intensity was relatively weak. An unexpected decrease of current amplitude was found for a laser pulse with a wavelength of 200 nm, which may indicate the transient break of pi bonds in linear carbon chains. For chains with more than 10 atoms, the excited current oscillated with increasing amplitude during simulation time, which was due to the formation of plasma-like resonance. - Highlights: • Excited currents is reversible when laser intensity was relatively weak. • A laser pulse with a wavelength of 200 nm can induce the transient break of pi bonds in linear carbon chains. • The excited current oscillate to form plasma-like resonance under laser field driving. • In the carbon chains with odd numbers, the uniform distribution of pi bonds created a “path” for electrons.

  8. Power nanosecond pulse shaping by means of RCD-generators with peaking circuits based on diode current breakers

    CERN Document Server

    Grekhov, I V; Korotkov, S V; Stepanyants, A L; Khristyuk, D V

    2002-01-01

    One considered the basic principles to design nanosecond region generators based on reverse-connected dynistos (RCD) with diode current breaker base output peaking circuits. Paper presents the results of experimental investigation in intense generator based on RCD, peaking pulsed transformer and high-voltage diode breaker from a set of series-connected drift diodes with abrupt reset. Generator at 1 kHz frequency commutates voltage pulses with approx 45 kV amplitude, approx 50 ns duration and approx 10 ns rise front to 25 ohm load

  9. Formation of Structure in Hard-Alloy Coatings from Powders Under Passage of a Powerful Pulse of Electric Current

    Science.gov (United States)

    Novikov, S. V.; Peretyagin, P. Yu.; Dolzhikova, E. Yu.; Torrecillas, R.

    2016-01-01

    A method of ultrafast deposition of hard-alloy coatings from powders upon passage of a powerful pulse of electric current is considered. The structure of the coatings obtained by the electric-pulse and standard processes is studied by metallographic, electron microscope and x-ray diffraction analyses. The physical, mechanical and cutting properties of the hard-alloy coatings are determined. The endurance of the cutting tools with hard-alloy coatings is estimated under the conditions of large-scale and pilot productions. The possibility of creation of tools with enhanced operating characteristics is demonstrated.

  10. Multiscale wind cycles and current pulses at the Black Sea eastern boundary

    Science.gov (United States)

    Melnikov, Vasiliy; Moskalenko, Lidija; Piotoukh, Vladimir; Zatsepin, Andrey

    2015-04-01

    quantified anomalies, associated with different frequency components of variability, such as sub-meso-scale eddies, marginal shelf waves, inertial oscillations, diurnal, semi-diurnal and short-period internal waves, long surface waves, were estimated. Based on estimates of the statistical relationships between the different parameters of hydro-meteorological system, including meteorological elements, sea level, sea temperature and flow fields, space/time scales of the observed fields variability were estimated. Several new features of the physical mechanisms of multiscale hydro-physical processes in the shelf zone of the Black Sea, have been revealed. In particular, it is shown, that there are wind self-similar cycles at different time scales, each cycle being consisted of a pair of northeast and then southeast winds, which corresponds to the alternative influences of the Azores and Siberian highs(in winter). In the range of decadal (10 years) scale and in macro space view, long-term wind cycles support basic Black Sea circulation(Rim Current).Wind cycles with a time scale of about 20 days give rise to distinct upwellings, appeared with the same frequency. Along with each upwelling, radical hydrological restructuring of the stratification is accompanied by intense advection with high velocities(up to 1 m/s). Kinetic energy is dominated by alongshore currents, the direction being reversed periodically. The vertical structure of currents is rather complicated. When the current speed exceeds some threshold value, the flow gives rise to relaxation oscillations with a period of about 24 hours with counterclockwise velocity vector rotation. All the above mentioned events and current pulses cause significant variations of air-sea fluxes. This research was jointly supported by Ministry of Education of the RF (Agreement №14.604.21.0044), Russian Academy of Sciences(Program No 23), RFBR grant 14-05-00159,contract No 10/2013 RGS-RFBR.

  11. The Effects of High-Volt Pulsed Current Electrical Stimulation on Delayed-Onset Muscle Soreness

    Science.gov (United States)

    Butterfield, David Lynn; Draper, David O.; Ricard, Mark D.; Myrer, J. William; Schulthies, Shane S.; Durrant, Earlene

    1997-01-01

    Objective: We investigated three 30-minute high-volt pulsed current electrical stimulation (HVPC) treatments of 125 pps to reduce pain, restore range of motion (ROM), and recover strength loss associated with delayed-onset muscle soreness (DOMS). Design and Setting: Randomized, masked comparison of three 30-minute treatment and sham HVPC regimens over a 48-hour period. Subjects: Twenty-eight college students. Measurements: Subjects performed concentric and eccentric knee extensions with the right leg to induce muscle soreness. Assessments were made before and after the exercise bout and each treatment at 24, 48, and 72 hours postexercise. Results: Three separate 2 × 3 × 2 ANOVAs were used to determine significant differences (p < .05) between days, treatments, and pre-post treatment effects and significant interaction among these variables. Scheffe post hoc tests showed no significant reduction in pain perception or improvement in loss of function at 24, 48, and 72 hours postexercise. Mean pain perception assessments (0 = no pain, 10 = severe pain) for the HVPC group were 2.9, 4.5, and 3.5 and for the sham group 3.8, 4.8, and 3.5). Mean ROM losses for the HVPC group were 9.0°, 22.3°, and 26.2°, and for the sham group were 9.5°, 23.1°, and 23.0°. Mean strength losses (1RM) for the HVPC group were 25.9, 25.7, and 20.8 lbs and for the sham group were 22.3, 22.3, and 13.8 lbs. Conclusions: HVPC as we studied it was ineffective in providing lasting pain reduction and at reducing ROM and strength losses associated with DOMS. PMID:16558426

  12. Mechanical and Thermal Properties of Pulsed Electric Current Sintered (PECS) Cu-Diamond Compacts

    Science.gov (United States)

    Ritasalo, Riina; Kanerva, Ulla; Ge, Yanling; Hannula, Simo-Pekka

    2014-04-01

    In this work, dispersion strengthening of copper by diamonds is explored. In particular, the influence of 50- and 250-nm diamonds at contents of 3 and 6 vol. pct on the mechanical and thermal properties of pulsed electric current sintered (PECS) Cu composites is studied. The composite powders were prepared by mechanical alloying in argon atmosphere using a high-energy vibratory ball mill. The PECS compacts prepared had high density (>97 pct of T.D.) with quite evenly distributed diamonds. The effectiveness of dispersoids in increasing the microhardness was more pronounced at a smaller particle size and larger volume fraction, explained by Hall-Petch and Orowan strengthening models. The microhardness of Cu with 6 and 3 vol. pct nanodiamonds and pure sm-Cu (submicron-sized Cu) was 1.77, 1.46, and 1.02 GPa, respectively. In annealing experiments at 623 K to 873 K (350 °C to 600 °C), the composites with 6 vol. pct dispersoids retained their hardness better than those with less dispersoids or sm-Cu. The coefficient of thermal expansion was lowered when diamonds were added, being the lowest at about 14 × 10-6 K-1 between 473 K and 573 K (200 °C and 300 °C). Good bonding between the copper and diamond was qualitatively demonstrated by nanoindentation. In conclusion, high-quality Cu-diamond composites can be produced by PECS with improved strength and better thermal stability than for sm-Cu.

  13. Analysis and Minimization of Output Current Ripple for Discontinuous Pulse-Width Modulation Techniques in Three-Phase Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2016-05-01

    Full Text Available This paper gives the complete analysis of the output current ripple in three-phase voltage source inverters considering the different discontinuous pulse-width modulation (DPWM strategies. In particular, peak-to-peak current ripple amplitude is analytically evaluated over the fundamental period and compared among the most used DPWMs, including positive and negative clamped (DPWM+ and DPWM−, and the four possible combinations between them, usually named as DPWM0, DPWM1, DPWM2, and DPWM3. The maximum and the average values of peak-to-peak current ripple are estimated, and a simple method to correlate the ripple envelope with the ripple rms is proposed and verified. Furthermore, all the results obtained by DPWMs are compared to the centered pulse-width modulation (CPWM, equivalent to the space vector modulation to identify the optimal pulse-width modulation (PWM strategy as a function of the modulation index, taking into account the different average switching frequency. In this way, the PWM technique providing for the minimum output current ripple is identified over the whole modulation range. The analytical developments and the main results are experimentally verified by current ripple measurements with a three-phase PWM inverter prototype supplying an induction motor load.

  14. Use of alternating and pulsed direct current electrified fields for zebra mussel control

    Science.gov (United States)

    Luoma, James A.; Dean, Jan C.; Severson, Todd J.; Wise, Jeremy K.; Barbour, Matthew

    2017-01-01

    Alternatives to chemicals for controlling dreissenid mussels are desirable for environmental compatibility, but few alternatives exist. Previous studies have evaluated the use of electrified fields for stunning and/or killing planktonic life stages of dreissenid mussels, however, the available literature on the use of electrified fields to control adult dreissenid mussels is limited. We evaluated the effects of sinusoidal alternating current (AC) and 20% duty cycle square-wave pulsed direct current (PDC) exposure on the survival of adult zebra mussels at water temperatures of 10, 15, and 22 °C. Peak voltage gradients of ~ 17 and 30 Vp/cm in the AC and PDC exposures, respectively, were continuously applied for 24, 48, or 72 h. Peak power densities ranged from 77,999 to 107,199 µW/cm3 in the AC exposures and 245,320 to 313,945 µW/cm3 in the PDC exposures. The peak dose ranged from 6,739 to 27,298 Joules/cm3 and 21,306 to 80,941 Joules/cm3 in the AC and PDC exposures, respectively. The applied power ranged from 16.6 to 68.9 kWh in the AC exposures and from 22.2 to 86.4 kWh in the PDC exposures. Mortality ranged from 2.7 to 92.7% in the AC exposed groups and from 24.0 to 98.7% in PDC exposed groups. Mortality increased with corresponding increases in water temperature and exposure duration, and we observed more zebra mussel mortality in the PDC exposures. Exposures conducted with AC required less of a peak dose (Joules/cm3) but more applied power (kWh) to achieve the same level of adult zebra mussel mortality as corresponding PDC exposures. The results demonstrate that 20% duty cycle square-wave PDC requires less energy than sinusoidal AC to inducing the same level of adult zebra mussel mortality.

  15. Steel Pulsed Eddy Current Testing Method%钢板脉冲涡流检测方法

    Institute of Scientific and Technical Information of China (English)

    杨理践; 裴磊; 杨继华

    2011-01-01

    In order to effectively increase the depth of penetration of pulsed eddy current signals to detect cracks in steel plate,this paper presented the method of increasing the excitation current. It used low voltage high current power supply and power MOSFET chopper means to produce a large current pulse. It designed the pulsed eddy current probe which composed of the rectangular coils and two Hall sensors. And the amplifying and filtering circuit was made. It adopted the data acquisition card to acquire signals. It used LabVIEW platform, with peak scanning method, realized pulsed eddy current signals differential detection, to effectively identify the sub-surface cracks in thick steel plate.%为了有效增加脉冲涡流信号的渗透深度以检测较厚钢板裂纹缺陷,提出了增大激励电流的方法.用低压大电流电源和功率MOSFET斩波的方式产生大电流脉冲;设计了由矩形激励线圈和2片霍尔传感器构成的脉冲涡流检测探头并制作放大滤波电路;采用数据采集卡采集信号,以LabVIEW为平台,采用峰值扫描方法,实现脉冲涡流信号的差分检测,达到有效识别较厚钢板亚表面裂纹缺陷.

  16. Intense Pulsed Heavy Ion Beam Technology

    Science.gov (United States)

    Masugata, Katsumi; Ito, Hiroaki

    Development of intense pulsed heavy ion beam accelerator technology is described for the application of materials processing. Gas puff plasma gun and vacuum arc discharge plasma gun were developed as an active ion source for magnetically insulated pulsed ion diode. Source plasma of nitrogen and aluminum were successfully produced with the gas puff plasma gun and the vacuum arc plasma gun, respectively. The ion diode was successfully operated with gas puff plasma gun at diode voltage 190 kV, diode current 2.2 kA and nitrogen ion beam of ion current density 27 A/cm2 was obtained. The ion composition was evaluated by a Thomson parabola spectrometer and the purity of the nitrogen ion beam was estimated to be 86%. The diode also operated with aluminum ion source of vacuum arc plasma gun. The ion diode was operated at 200 kV, 12 kA, and aluminum ion beam of current density 230 A/cm2 was obtained. The beam consists of aluminum ions (Al(1-3)+) of energy 60-400 keV, and protons (90-130 keV), and the purity was estimated to be 89 %. The development of the bipolar pulse accelerator (BPA) was reported. A double coaxial type bipolar pulse generator was developed as the power supply of the BPA. The generator was tested with dummy load of 7.5 ohm, bipolar pulses of -138 kV, 72 ns (1st pulse) and +130 kV, 70 ns (2nd pulse) were succesively generated. By applying the bipolar pulse to the drift tube of the BPA, nitrogen ion beam of 2 A/cm2 was observed in the cathode, which suggests the bipolar pulse acceleration.

  17. Influence of pulsing current on the glass transition and crystallizing kinetics of a Zr base bulk amorphous alloy

    Institute of Scientific and Technical Information of China (English)

    WU Wenfei; YAO Kefu; ZHAO Zhankui

    2004-01-01

    Based on the thermal analysis, the influence of pulsing current on the glass transition and crystallizing kinetics of Zr41.3Ti14.2Cu12.8Ni10.3Be21.4 bulk amorphous alloy has been studied. The obtained results show that after the Zr41.3Ti14.2Cu12.8Ni10.3Be21.4 bulk amorphous alloy was pretreated by high-density pulsing current at low temperature, its glass transition temperature Tg, the initial crystallizing temperature Tx and the corresponding exothermic peak of crystallization Tpi were reduced. But the temperature range of supercooled liquid ΔT=Tx-Tg is almost the same. The calculated results with Kissinger equation show that the activation energy of glass transition of the alloy pretreated is reduced significantly, while the activation energy of crystallization is basically unchanged. The influence of pulsing current on the glass transition and crystallization of the Zr41.3Ti14.2Cu12.8Ni10.3Be21.4 bulk amorphous alloy is believed to be related with the structure relaxation of the glass caused by the current.

  18. AVERAGE GEOMETRICAL FEATURES OF THE ELECTRON WAVE PACKAGES DISTRIBUTION IN METALLIC CONDUCTORS WITH PULSED AXIAL CURRENT OF HIGH DENSITY

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2016-11-01

    Full Text Available Purpose. Calculation and experimental determination of average geometrical features of distributing of macroscopic electron wave packages (EWP in round cylindrical metallic conductors with the pulsed axial current of high density. Methodology. Theoretical bases of the electrical engineering, bases of atomic and quantum physics, electrophysics bases of technique of high voltage and high pulsed currents. Results. The results of the conducted calculation and experimental researches are resulted on close determination of average geometrical features of distribution of longitudinal and radial EWP of macroscopic sizes in the indicated conductors. These descriptions are included by the average widths of «hot» and «cold» longitudinal and radial areas of conductor, and also average steps of division into the periods of similar areas. Results of the executed calculations and high temperature experiments for average geometrical features of longitudinal EWP in the zincked steel wire of diameter of 1.6 mm and length of 320 mm with the aperiodic impulse of current of temporal form 9 ms/160 ms and by amplitude 745 A coincide within the limits of 19 %. Originality. First with the use of methods of atomic and quantum physics the features of the stochastic distributing and mean values of basic geometrical sizes are analysed macroscopic longitudinal and radial EWP in round cylindrical metallic conductors with the pulsed axial current of high density. Practical value. Drawing on the got results in practice will allow more reliably to forecast geometrical sizes and places of localization of arising up in the probed metallic conductors with pulsed axial current of high density longitudinal and radial EWP.

  19. Influence of magnetic arc oscillation and current pulsing on microstructure and high temperature tensile strength of alloy 718 TIG weldments

    Energy Technology Data Exchange (ETDEWEB)

    Sivaprasad, K. [Department of Metallurgical and Materials Engineering, Indian Institute of Technology Madras, Chennai (India); Ganesh Sundara Raman, S. [Department of Metallurgical and Materials Engineering, Indian Institute of Technology Madras, Chennai (India)]. E-mail: ganesh@iitm.ac.in; Mastanaiah, P. [Defence Research and Development Laboratory, Hyderabad (India); Madhusudhan Reddy, G. [Defence Metallurgical Research Laboratory, Hyderabad (India)

    2006-07-25

    The aim of the present work is to study the effect of magnetic arc oscillation and current pulsing on the microstructure and high temperature tensile strength of alloy 718 tungsten inert gas weldments. The magnetic arc oscillation technique resulted in refined Laves phase with lesser interconnectivity. The full benefits of current pulsing in breaking the dendrites could not be realized in the present study due to relatively higher heat input used in the welding process. In the direct aged condition weldments prepared using magnetic arc oscillation technique exhibited higher tensile strength due to the presence of refined and lesser-interconnected Laves particles. In the solution treated and aged condition, magnetic arc oscillated weldments exhibited lower tensile strength compared with the weldments made without arc oscillation due to the presence of large amounts of finer {delta} needles.

  20. Pulsed Current-Mode Supply of Dielectric Barrier Discharge Excilamps for the Control of the Radiated Ultraviolet Power

    OpenAIRE

    2010-01-01

    International audience; UV excimer lamps are efficient narrowband sources of UV radiation with applications in various domains. The issue of controlling the UV emission by means of the power supply associated with such lamps favors pulsed current-controlled generators. After having established the previous statements, we propose a dedicated power converter topology which implements the needed performances. The analysis of the degrees of freedom of this structure shows the capability of this pu...

  1. Surface Nanocrystallization of 3Cr13 Stainless Steel Induced by High-Current Pulsed Electron Beam Irradiation

    OpenAIRE

    2013-01-01

    The nanocrystalline surface was produced on 3Cr13 martensite stainless steel surface using high-current pulsed electron beam (HCPEB) technique. The structures of the nanocrystallized surface were characterized by X-ray diffraction and electron microscopy. Two nanostructures consisting of fine austenite grains (50–150 nm) and very fine carbides precipitates are formed in melted surface layer after multiple bombardments via dissolution of carbides and crater eruption. It is demonstrated that th...

  2. Development of long pulse RF heating and current drive for H-mode scenarios with metallic walls in WEST

    Energy Technology Data Exchange (ETDEWEB)

    Ekedahl, Annika, E-mail: annika.ekedahl@cea.fr; Bourdelle, Clarisse; Artaud, Jean-François; Bernard, Jean-Michel; Bufferand, Hugo; Colas, Laurent; Decker, Joan; Delpech, Léna; Dumont, Rémi; Goniche, Marc; Helou, Walid; Hillairet, Julien; Lombard, Gilles; Magne, Roland; Mollard, Patrick; Nardon, Eric; Peysson, Yves; Tsitrone, Emmanuelle [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France)

    2015-12-10

    The longstanding expertise of the Tore Supra team in long pulse heating and current drive with radiofrequency (RF) systems will now be exploited in the WEST device (tungsten-W Environment in Steady-state Tokamak) [1]. WEST will allow an integrated long pulse tokamak programme for testing W-divertor components at ITER-relevant heat flux (10-20 MW/m{sup 2}), while treating crucial aspects for ITER-operation, such as avoidance of W-accumulation in long discharges, monitoring and control of heat fluxes on the metallic plasma facing components (PFCs) and coupling of RF waves in H-mode plasmas. Scenario modelling using the METIS-code shows that ITER-relevant heat fluxes are compatible with the sustainment of long pulse H-mode discharges, at high power (up to 15 MW / 30 s at I{sub P} = 0.8 MA) or high fluence (up to 10 MW / 1000 s at I{sub P} = 0.6 MA) [2], all based on RF heating and current drive using Ion Cyclotron Resonance Heating (ICRH) and Lower Hybrid Current Drive (LHCD). This paper gives a description of the ICRH and LHCD systems in WEST, together with the modelling of the power deposition of the RF waves in the WEST-scenarios.

  3. Diagnostics for a 1.2 kA, 1 MeV, electron induction injector

    Science.gov (United States)

    Houck, T. L.; Anderson, D. E.; Eylon, S.; Henestroza, E.; Lidia, S. M.; Vanecek, D. L.; Westenskow, G. A.; Yu, S. S.

    1998-12-01

    We are constructing a 1.2 kA, 1 MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility. The electron source will be a 3.5″-diameter, thermionic, flat-surface, m-type cathode with a maximum shroud field stress of approximately 165 kV/cm. Additional design parameters for the injector include a pulse length of over 150 ns flat top (1% energy variation), and a normalized edge emittance of less than 200 π-mm-mr. Precise measurement of the beam parameters is required so that performance of the RTA injector can be confidently scaled to the 4 kA, 3 MeV, and 2-microsecond pulse parameters of the DARHT injector. Planned diagnostics include an isolated cathode with resistive divider for direct measurement of current emission, resistive wall and magnetic probe current monitors for measuring beam current and centroid position, capacitive probes for measuring A-K gap voltage, an energy spectrometer, and a pepperpot emittance diagnostic. Details of the injector, beam line, and diagnostics are presented.

  4. Diagnostics for a 1.2 kA, 1 MeV electron induction injector

    Energy Technology Data Exchange (ETDEWEB)

    Houck, T.L.; Anderson, D.E.; Eylon, S.; Henestroza, E.; Lidia, S.M.; Vanecek, D.L.; Westenskow, G.A.; Yu, S.S.

    1998-05-11

    We are constructing a 1.2-kA, 1-MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility. The electron source will be a 3.5``-diameter, thermionic, flat-surface, m-type cathode with a maximum shroud field stress of approximately 165 kV/cm. Additional design parameters for the injector include a pulse length of over 150-ns flat top (1% energy variation), and a normalized edge emittance of less than 200 {pi}-mm-mr. Precise measurement of the beam parameters is required so that performance of the RTA injector can be confidently scaled to the 4-kA, 3-MeV, and 2-microsecond pulse parameters of the DARHT injector. Planned diagnostics include an isolated cathode with resistive divider for direct measurement of current emission, resistive wall and magnetic probe current monitors for measuring beam current and centroid position, capacitive probes for measuring A-K gap voltage, an energy spectrometer, and a pepper-pot emittance diagnostic. Details of the injector, beam line, and diagnostics are presented.

  5. A Novel Transcranial Magnetic Stimulator Inducing Near Rectangular Pulses with Controllable Pulse Width (cTMS)

    Science.gov (United States)

    Jalinous, Reza; Lisanby, Sarah H.

    2013-01-01

    A novel transcranial magnetic stimulation (TMS) device with controllable pulse width (PW) and near rectangular pulse shape (cTMS) is described. The cTMS device uses an insulated gate bipolar transistor (IGBT) with appropriate snubbers to switch coil currents up to 7 kA, enabling PW control from 5 μs to over 100 μs. The near-rectangular induced electric field pulses use 22–34% less energy and generate 67–72% less coil heating compared to matched conventional cosine pulses. CTMS is used to stimulate rhesus monkey motor cortex in vivo with PWs of 20 to 100 μs, demonstrating the expected decrease of threshold pulse amplitude with increasing PW. The technological solutions used in the cTMS prototype can expand functionality, and reduce power consumption and coil heating in TMS, enhancing its research and therapeutic applications. PMID:18232369

  6. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  7. Analysis of Current Pulses in HeLa-Cell Permeabilization Due to High Voltage DC Corona Discharge.

    Science.gov (United States)

    Chetty, Nevendra K; Chonco, Louis; Ijumba, Nelson M; Chetty, Leon; Govender, Thavendran; Parboosing, Raveen; Davidson, Innocent E

    2016-09-01

    Corona discharges are commonly utilized for numerous practical applications, including bio-technological ones. The corona induced transfer of normally impermeant molecules into the interior of biological cells has recently been successfully demonstrated. The exact nature of the interaction of the corona discharge with a cell membrane is still unknown, however, previous studies have suggested that it is either the electric fields produced by ions or the chemical interaction of the reactive species that result in the disruption of the cell membrane. This disruption of the cell membrane allows molecules to permeate into the cell. Corona discharge current constitutes a series of pulses, and it is during these pulses that the ions and reactive species are produced. It stands to reason, therefore, that the nature of these corona pulses would have an influence on the level of cell permeabilization and cell destruction. In this investigation, an analysis of the width, rise-time, characteristic frequencies, magnitude, and repetition rate of the nanosecond pulses was carried out in order to establish the relationship between these factors and the levels of cell membrane permeabilization and cell destruction. Results obtained are presented and discussed.

  8. The structure and properties of boron carbide ceramics modified by high-current pulsed electron-beam

    Science.gov (United States)

    Ivanov, Yuri; Tolkachev, Oleg; Petyukevich, Maria; Teresov, Anton; Ivanova, Olga; Ikonnikova, Irina; Polisadova, Valentina

    2016-01-01

    The present work is devoted to numerical simulation of temperature fields and the analysis of structural and strength properties of the samples surface layer of boron carbide ceramics treated by the high-current pulsed electron-beam of the submillisecond duration. The samples made of sintered boron carbide ceramics are used in these investigations. The problem of calculating the temperature field is reduced to solving the thermal conductivity equation. The electron beam density ranges between 8…30 J/cm2, while the pulse durations are 100…200 μs in numerical modelling. The results of modelling the temperature field allowed ascertaining the threshold parameters of the electron beam, such as energy density and pulse duration. The electron beam irradiation is accompanied by the structural modification of the surface layer of boron carbide ceramics either in the single-phase (liquid or solid) or two-phase (solid-liquid) states. The sample surface of boron carbide ceramics is treated under the two-phase state (solid-liquid) conditions of the structural modification. The surface layer is modified by the high-current pulsed electron-beam produced by SOLO installation at the Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia. The elemental composition and the defect structure of the modified surface layer are analyzed by the optical instrument, scanning electron and transmission electron microscopes. Mechanical properties of the modified layer are determined measuring its hardness and crack resistance. Research results show that the melting and subsequent rapid solidification of the surface layer lead to such phenomena as fragmentation due to a crack network, grain size reduction, formation of the sub-grained structure due to mechanical twinning, and increase of hardness and crack resistance.

  9. The structure and properties of boron carbide ceramics modified by high-current pulsed electron-beam

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Yuri, E-mail: yufi55@mail.ru [Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences, 2/3 Akademicheskiy Ave. Tomsk, 634055 (Russian Federation); National Research Tomsk State University, 36 Lenina Str., Tomsk, 634050 (Russian Federation); National Research Tomsk Polytechnic University, 30 Lenina Str., Tomsk, 634050 (Russian Federation); Tolkachev, Oleg, E-mail: ole.ts@mail.ru; Petyukevich, Maria, E-mail: petukevich@tpu.ru; Polisadova, Valentina, E-mail: polis@tpu.ru [National Research Tomsk Polytechnic University, 30 Lenina Str., Tomsk, 634050 (Russian Federation); Teresov, Anton, E-mail: tad514@sibmail.com [Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences, 2/3 Akademicheskiy Ave. Tomsk, 634055 (Russian Federation); National Research Tomsk State University, 36 Lenina Str., Tomsk, 634050 (Russian Federation); Ivanova, Olga, E-mail: ivaov@mail.ru; Ikonnikova, Irina, E-mail: irina-ikonnikova@yandex.ru [Tomsk State University of Architecture and Building, 2 Solyanaya Sq., Tomsk, 634003 (Russian Federation)

    2016-01-15

    The present work is devoted to numerical simulation of temperature fields and the analysis of structural and strength properties of the samples surface layer of boron carbide ceramics treated by the high-current pulsed electron-beam of the submillisecond duration. The samples made of sintered boron carbide ceramics are used in these investigations. The problem of calculating the temperature field is reduced to solving the thermal conductivity equation. The electron beam density ranges between 8…30 J/cm{sup 2}, while the pulse durations are 100…200 μs in numerical modelling. The results of modelling the temperature field allowed ascertaining the threshold parameters of the electron beam, such as energy density and pulse duration. The electron beam irradiation is accompanied by the structural modification of the surface layer of boron carbide ceramics either in the single-phase (liquid or solid) or two-phase (solid-liquid) states. The sample surface of boron carbide ceramics is treated under the two-phase state (solid-liquid) conditions of the structural modification. The surface layer is modified by the high-current pulsed electron-beam produced by SOLO installation at the Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia. The elemental composition and the defect structure of the modified surface layer are analyzed by the optical instrument, scanning electron and transmission electron microscopes. Mechanical properties of the modified layer are determined measuring its hardness and crack resistance. Research results show that the melting and subsequent rapid solidification of the surface layer lead to such phenomena as fragmentation due to a crack network, grain size reduction, formation of the sub-grained structure due to mechanical twinning, and increase of hardness and crack resistance.

  10. Temperature increase due to Joule heating in a nanostructured MgO-based magnetic tunnel junction over a wide current-pulse range.

    Science.gov (United States)

    Jeong, Boram; Lim, Sang Ho

    2011-07-01

    The temperature increase due to Joule heating in a nanopillar of a magnetic tunnel junction sandwiched by top and bottom electrodes was calculated by the finite element method. The results for the critical condition for the current-induced magnetization switching measured over a wide current-pulse range were taken from the literature. At long pulse widths, the temperature increase was solely dependent on the magnitude of the critical current density. However, no saturation in the temperature increase occurred for short pulse widths. In this case, the temperature increase additionally depended on the pulse width, so that a broad maximum occurred in the pulse width (or the critical current density) dependence of the temperature increase. The original results for the critical condition were corrected by accounting for the temperature increase and these corrected results, together with the Slonczewski equation, were used to extract an accurate value for the thermal stability factor.

  11. AUTOREGRESSIVE MODEL AND POWER SPECTRUM CHARATERISTICS OF CURRENT SIGNAL IN HIGH FREQUENCY GROUP PULSE MICRO ELECTROCHEMICAL MACHINING

    Institute of Scientific and Technical Information of China (English)

    TANG Xinglun; ZHANG Zhijing; ZHOU Zhaoying; YANG Xiaodong

    2006-01-01

    The identification of the inter-electrode gap size in the high frequency group pulse micro-electrochemical machining (HGPECM) is mainly discussed. The auto-regressive(AR) model of group pulse current flowing across the cathode and the anode are created under different situations with different processing parameters and inter-electrode gap size. The AR model based on the current signals indicates that the order of the AR model is obviously different relating to the different processing conditions and the inter-electrode gap size; Moreover, it is different about the stability of the dynamic system, i.e. the white noise response of the Green's function of the dynamic system is diverse. In addition, power spectrum method is used in the analysis of the dynamic time series about the current signals with different inter-electrode gap size, the results show that there exists a strongest power spectrum peak, characteristic power spectrum(CPS), to the current signals related to the different inter-electrode gap size in the range of 0~5 kHz. Therefore, the CPS of current signals can implement the identification of the inter-electrode gap.

  12. Optimizing pulsed current gas tungsten arc welding parameters of AA6061 aluminium alloy using Hooke and Jeeves algorithm

    Institute of Scientific and Technical Information of China (English)

    S. BABU; T. SENTHIL KUMAR; V. BALASUBRAMANIAN

    2008-01-01

    Though the preferred welding process to weld aluminium alloy is frequently constant current gas tungsten arc welding (CCGTAW), it resulted in grain coarsening at the fusion zone and heat affected zone(HAZ). Hence, pulsed current gas tungsten arc welding(PCGTAW) was performed, to yield finer fusion zone grains, which leads to higher strength of AA6061 (Al-Mg-Si) aluminium alloy joints. In order to determine the most influential control factors which will yield minimum fusion zone grain size and maximum tensile strength of the joints, the traditional Hooke and Jeeves pattern search method was used. The experiments were carried out based on central composite design with 31 runs and an algorithm was developed to optimize the fusion zone grain size and the tensile strength of pulsed current gas tungsten arc welded AA6061 aluminium aUoy joints. The results indicate that the peak current (Ip) and base current (IB) are the most significant parameters, to decide the fusion zone grain size and the tensile strength of the AA6061 aluminum alloy joints.

  13. A 16 MJ compact pulsed power system for electromagnetic launch

    Science.gov (United States)

    Dai, Ling; Zhang, Qin; Zhong, Heqing; Lin, Fuchang; Li, Hua; Wang, Yan; Su, Cheng; Huang, Qinghua; Chen, Xu

    2015-07-01

    This paper has established a compact pulsed power system (PPS) of 16 MJ for electromagnetic rail gun. The PPS consists of pulsed forming network (PFN), chargers, monitoring system, and current junction. The PFN is composed of 156 pulse forming units (PFUs). Every PFU can be triggered simultaneously or sequentially in order to obtain different total current waveforms. The whole device except general control table is divided into two frameworks with size of 7.5 m × 2.2 m × 2.3 m. It is important to estimate the discharge current of PFU accurately for the design of the whole electromagnetic launch system. In this paper, the on-state characteristics of pulse thyristor have been researched to improve the estimation accuracy. The on-state characteristics of pulse thyristor are expressed as a logarithmic function based on experimental data. The circuit current waveform of the single PFU agrees with the simulating one. On the other hand, the coaxial discharge cable is a quick wear part in PFU because the discharge current will be up to dozens of kA even hundreds of kA. In this article, the electromagnetic field existing in the coaxial cable is calculated by finite element method. On basis of the calculation results, the structure of cable is optimized in order to improve the limit current value of the cable. At the end of the paper, the experiment current wave of the PPS with the load of rail gun is provided.

  14. Inductive Pulse Forming Network For High-Current, High-Power Applications

    OpenAIRE

    2011-01-01

    Patent An inductive pulse forming network stores electrical energy delivered from an outside prime power supply in the electric field of a low-voltage, high-energy density network capacitor. Through timed actuation of a series of one or more switches, the energy stored in the electric field of the network capacitor is subsequently converted to electrical energy stored in the magnetic field of a network inductor. The energy stored in the network inductor supplies high-c...

  15. Mechanism and microstructure of nickel-ceria composite coatings prepared by pulse current deposition under the ultrasonic field

    Institute of Scientific and Technical Information of China (English)

    ZHOU Xiaowei; SHEN Yifu; ZHENG Yingying; JIN Huiming

    2011-01-01

    In recent research,a novel method combined with pulse current (PC) deposition and the ultrasonic (U) field was used to fabricate pure nickel and nickel-ceria composite coatings,respectively.Morphology,crack propagation,and crystal texture were observed and analysed by using environment seanning electron microscopy (E-SEM) and transmission electron microscopy (TEM).Orthogonal experiment [L16 (45)] was designed to optimize the parameters of pulsed power and the appropriate amount of RE addition based on microhardness.Effect of RE addition and pulsed current on the mechanism of co-electrodeposition was also investigated and compared.Experimental results indicated that it produced the alloying coatings,exhibiting compact grain and amorphous state.Nano-sized RE would preferentially occupy and pad at the edge of cracked gaps and micropore to limit the growing location and space for coarse Ni grain.Furthermore,during annealing at 480 ℃ for 2 h,a solid-solution precipitated phase named NiCexO1-x (0<x<0.5) dispersed along the large crystal boundary,which would make RE diffused sufficiently to improve crack propagation resistance and promote densifieation efficiently.

  16. Growth of doped silicon nanowires by pulsed laser deposition and their analysis by electron beam induced current imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhawer, B; Berger, A; Christiansen, S [Institute of Photonic Technology, Albert-Einstein-Strasse 9, 07745 Jena (Germany); Zhang, D; Clavel, R [Laboratory of Robotic Systems, Ecole Polytechnique Federale de Lausanne (EPFL), Station 9, CH-1015 Lausanne (Switzerland); Michler, J, E-mail: bjoern.eisenhawer@ipht-jena.de [Mechanics of Materials and Nanostructures Laboratory, EMPA-Materials Science and Technology, Feuerwerkstrasse 39, CH-3602 Thun (Switzerland)

    2011-02-18

    Doped silicon nanowires (NWs) were epitaxially grown on silicon substrates by pulsed laser deposition following a vapour-liquid-solid process, in which dopants together with silicon atoms were introduced into the gas phase by laser ablation of lightly and highly doped silicon target material. p-n or p{sup ++}-p junctions located at the NW-silicon substrate interfaces were thus realized. To detect these junctions and visualize them the electron beam induced current technique and two-point probe current-voltage measurements were used, based on nanoprobing individual silicon NWs in a scanning electron microscope. Successful silicon NW doping by pulsed laser deposition of doped target material could experimentally be demonstrated. This doping strategy compared to the commonly used doping from the gas phase during chemical vapour deposition is evaluated essentially with a view to potentially overcoming the limitations of chemical vapour deposition doping, which shows doping inhomogeneities between the top and bottom of the NW as well as between the core and shell of NWs and structural lattice defects, especially when high doping levels are envisaged. The pulsed laser deposition doping technique yields homogeneously doped NWs and the doping level can be controlled by the choice of the target material. As a further benefit, this doping procedure does not require the use of poisonous gases and may be applied to grow not only silicon NWs but also other kinds of doped semiconductor NWs, e.g. group III nitrides or arsenides.

  17. Ion current extracted from a self ignition plasma around the target immersed in a pulsed rf ICP methane plasma

    Science.gov (United States)

    Tanaka, Takeshi; Watanabe, Satoshi; Mizuno, Giichiro; Takagi, Toshinori; Yoshida, Mitsuhiro; Horibe, Hiroshi; Yukimura, Ken

    2003-05-01

    When a pulsed voltage is applied to a target immersed in plasma, the surrounding medium of the target is self-ignited under an appropriate discharge condition. For a three-dimensional substrate, ion implantation and deposition of the plasma species are promising to be uniformly attained by the self-ignition plasma. A retained dose of conformal ion implantation may increase with the self-ignition plasma generated in the target-immersed plasma. Ion are extracted from both the target-immersed plasma and the self-ignition plasma. In this research, a stainless steel target with a diameter of 140 mm and a thickness of 18 mm was immersed in a pulsed inductively coupled methane plasma to which a pulse voltage of -400 V to -10 kV with a width of 12 μs was repeatedly applied. The self-ignition plasma was generated at the voltage higher than about -1.2 kV. It was found that the shape of the current waveform changes by varying the applied voltage due to the change of the current from the self-ignition plasma.

  18. Transient analysis and control of bias magnetic state in the transformer of on-line pulse-width-modulation switching full bridge direct current-direct current converter

    Science.gov (United States)

    Chen, Jiaxin; Guo, Youguang; Zhu, Jianguo; Wei Lin, Zhi

    2012-04-01

    This paper presents a finite element analysis (FEA) based method for analyzing and controlling the bias magnetic state of the transformer of a pulse-width-modulation (PWM) switching full bridge dc-dc converter. A field-circuit indirect coupling method for predicting the transient bias magnetic state is introduced first. To increase flexibility of the proposed method, a novel transformer model which can address not only its basic input-output characteristic, but also the nonlinear magnetizing inductance, is proposed. Both the asymmetric characteristic and the variable laws of the current flowing through the two secondary windings during the period of PWM switching-off state are highlighted. Finally, the peak magnetizing current controlled method based on the on-line magnetizing current computation is introduced. Analysis results show that this method can address the magnetic saturation at winding ends, and hence many previous difficulties, such as the start-up process and asymmetry of power electronics, can be easily controlled.

  19. Advanced Test Accelerator (ATA) pulse power technology development

    Energy Technology Data Exchange (ETDEWEB)

    Reginato, L.L.; Branum, D.; Cook, E.

    1981-03-09

    The Advanced Test Accelerator (ATA) is a pulsed linear induction accelerator with the following design parameters: 50 MeV, 10 kA, 70 ns, and 1 kHz in a ten-pulse burst. Acceleration is accomplished by means of 190 ferrite-loaded cells, each capable of maintaining a 250 kV voltage pulse for 70 ns across a 1-inch gap. The unique characteristic of this machine is its 1 kHz burst mode capability at very high currents. This paper dscribes the pulse power development program which used the Experimental Test Accelerator (ETA) technology as a starting base. Considerable changes have been made both electrically and mechanically in the pulse power components with special consideration being given to the design to achieve higher reliability. A prototype module which incorporates all the pulse power components has been built and tested for millions of shots. Prototype components and test results are described.

  20. Hybrid simulations of whistler waves generation and current closure by a pulsed tether in the ionosphere

    Science.gov (United States)

    Chang, C. L.; Lipatov, A. S.; Drobot, A. T.; Papadopoulos, K.; Satya-Narayana, P.

    1994-01-01

    The dynamic response of a magnetized collisionless plasma to an externally driven, finite size, sudden switch-on current source across the magnetic field has been studied using a two dimensional hybrid code. It was found that the predominant plasma response was the excitation of whistler waves and the formation of current closure by induced currents in the plasma. The results show that the current closure path consists of: (a) two antiparallel field-aligned current channels at the end of the imposed current sheet; and (b) a cross-field current region connecting these channels. The formation of the current closure path occured in the whistler timescale much shorter than that of MHD and the closure region expanded continuously in time. The current closure process was accompanied by significant energy loss due to whistler radiation.

  1. Production and characterization of transient heat and particle pulses in Pilot-PSI

    NARCIS (Netherlands)

    Zielinski, J. J.; Al, R.; van der Meiden, H.; Melissen, W.; Rapp, J.; De Temmerman, G.

    2011-01-01

    In this paper we report on the generation of high transient heat and particle fluxes in Pilot-PSI. A capacitor bank (8400 mu F, 37.8 kJ) is coupled to the plasma source to superimpose the pulsed plasma on the top of steady-state plasma beam. Discharge currents up to 11.6 kA were reached correspondin

  2. Microsecond ramp compression of a metallic liner driven by a 5 MA current on the SPHINX machine using a dynamic load current multiplier pulse shaping

    Science.gov (United States)

    d'Almeida, T.; Lassalle, F.; Morell, A.; Grunenwald, J.; Zucchini, F.; Loyen, A.; Maysonnave, T.; Chuvatin, A. S.

    2013-09-01

    SPHINX is a 6 MA, 1-μs Linear Transformer Driver (LTD) operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. Among the options that are currently being evaluated to improve the generator performances are an upgrade to a 20 MA, 1-μs LTD machine and various power amplification schemes, including a compact Dynamic Load Current Multiplier (DLCM). A method for performing magnetic ramp compression experiments, without modifying the generator operation scheme, was developed using the DLCM to shape the initial current pulse in order to obtain the desired load current profile. In this paper, we discuss the overall configuration that was selected for these experiments, including the choice of a coaxial cylindrical geometry for the load and its return current electrode. We present both 3-D Magneto-hydrodynamic and 1D Lagrangian hydrodynamic simulations which helped guide the design of the experimental configuration. Initial results obtained over a set of experiments on an aluminium cylindrical liner, ramp-compressed to a peak pressure of 23 GPa, are presented and analyzed. Details of the electrical and laser Doppler interferometer setups used to monitor and diagnose the ramp compression experiments are provided. In particular, the configuration used to field both homodyne and heterodyne velocimetry diagnostics in the reduced access available within the liner's interior is described. Current profiles measured at various critical locations across the system, particularly the load current, enabled a comprehensive tracking of the current circulation and demonstrate adequate pulse shaping by the DLCM. The liner inner free surface velocity measurements obtained from the heterodyne velocimeter agree with the hydrocode results obtained using the measured load current as the input. An extensive hydrodynamic analysis is carried out to examine information such as pressure and particle velocity history profiles or magnetic

  3. Microsecond ramp compression of a metallic liner driven by a 5 MA current on the SPHINX machine using a dynamic load current multiplier pulse shaping

    Energy Technology Data Exchange (ETDEWEB)

    D' Almeida, T.; Lassalle, F.; Morell, A.; Grunenwald, J.; Zucchini, F.; Loyen, A. [CEA, DAM, GRAMAT, F-46500 Gramat (France); Maysonnave, T. [International Technologies for High Pulsed Power, F-46500 Thégra (France); Chuvatin, A. S. [Laboratoire de Physique des Plasmas, Ecole Polytechnique, F-91128 Palaiseau (France)

    2013-09-15

    SPHINX is a 6 MA, 1-μs Linear Transformer Driver (LTD) operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. Among the options that are currently being evaluated to improve the generator performances are an upgrade to a 20 MA, 1-μs LTD machine and various power amplification schemes, including a compact Dynamic Load Current Multiplier (DLCM). A method for performing magnetic ramp compression experiments, without modifying the generator operation scheme, was developed using the DLCM to shape the initial current pulse in order to obtain the desired load current profile. In this paper, we discuss the overall configuration that was selected for these experiments, including the choice of a coaxial cylindrical geometry for the load and its return current electrode. We present both 3-D Magneto-hydrodynamic and 1D Lagrangian hydrodynamic simulations which helped guide the design of the experimental configuration. Initial results obtained over a set of experiments on an aluminium cylindrical liner, ramp-compressed to a peak pressure of 23 GPa, are presented and analyzed. Details of the electrical and laser Doppler interferometer setups used to monitor and diagnose the ramp compression experiments are provided. In particular, the configuration used to field both homodyne and heterodyne velocimetry diagnostics in the reduced access available within the liner's interior is described. Current profiles measured at various critical locations across the system, particularly the load current, enabled a comprehensive tracking of the current circulation and demonstrate adequate pulse shaping by the DLCM. The liner inner free surface velocity measurements obtained from the heterodyne velocimeter agree with the hydrocode results obtained using the measured load current as the input. An extensive hydrodynamic analysis is carried out to examine information such as pressure and particle velocity history profiles or

  4. Developments of compact pulsed-power system toward X-ray sources

    Directory of Open Access Journals (Sweden)

    Miyamoto Takuya

    2013-11-01

    Full Text Available In order to generate X-rays from X-pinch, the peak current and current-rising time required are estimated to be 100 kA and 100 ns, respectively. To obtain these parameters, we developed a pulsed-power system, which consists of a parallelized pulse-forming network (PFN. The 20 PFN modules of the system were driven at a charging voltage of 20 kV by a thin copper wire of load resistance. The results showed that the current and current-rising time are 18 kA and 107 ns, respectively. The wire/plasma temperature is 6.9 eV. The pulsed-power system is expected to generate X-rays from X-pinch by the proposed system. This can be achieved by raising the voltage and increasing the number of PFN modules.

  5. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.;

    2008-01-01

    This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches, re...

  6. Induction cascade with electro-explosive commutation of current for amplification of electric pulse power

    CERN Document Server

    Grabovskij, E V; Kuznetsov, V V; Lototskij, A P; Khaustov, E V; Khalimullin, Y A; Kasyanov, N Y; Kormilitsyn, A I; Filatov, V A; Shkolnikov, E Y

    2002-01-01

    Paper describes a circuit of power amplification induction cascade based on a two-loop solenoid and electrically exploded conductors serving as current breakers. Due to retention of the general magnetic flow current breaking in the first loop of accumulator results in current amplification in the second loop and in accelerated actuation of the second electrically exploded conductor. Current switching to load occurs with 20-fold reduction of charging current front duration and increase of its amplitude. Time to charge coil is selected within 300-350 mu s limits

  7. Electrochemically enhanced reduction of hexavalent chromium in contaminated clay: Kinetics, energy consumption, and application of pulse current

    DEFF Research Database (Denmark)

    Sun, Tian Ran; Pamukcu, Sibel; Ottosen, Lisbeth M.;

    2015-01-01

    Electrochemically enhanced reduction of Cr(VI) in clay medium is a technique based on inputting extra energy into the clay to drive the favorable redox reaction. In this study, the reducing reagent Fe(II) was transported into Cr(VI) spiked kaolinite clay by direct current to investigate the depen......Electrochemically enhanced reduction of Cr(VI) in clay medium is a technique based on inputting extra energy into the clay to drive the favorable redox reaction. In this study, the reducing reagent Fe(II) was transported into Cr(VI) spiked kaolinite clay by direct current to investigate......,Fe)(OH)3] precipitates. XRD analysis suggested that the [(Cr,Fe)(OH)3] formed at the clay surface and grew into the pore fluid. SEM-EDX results indicated that the overall Fe(III):Cr(III) ratio of the precipitates was approximately 1.26:1. Application of pulse current decreased the non-productive energy...

  8. Formation Mechanism of Micropores on the Surface of Pure Aluminum Induced by High-Current Pulsed Electron Beam Irradiation

    Institute of Scientific and Technical Information of China (English)

    ZOU Yang; CAI Jie; WAN Ming-Zhen; LV Peng; GUAN Qing-Feng

    2011-01-01

    The mechanism of micropores formed on the surface of polycrystalline pure aluminum under high-current pulsed electron beam (HCPEB) irradiation is explained. It is discovered that dispersed micropores with sizes of 0.1-1μm on the irradiated surface of pure aluminum can be successfully fabricated after HCPEB irradiation. The dominant formation mechanism of the surface micropores should be attributed to the formation of supersaturation vacancies within the near surface during the HCPEB irradiation and the migration of vacancies along gra,in boundaries and/or dislocations towards the irradiated surface. It is expected that the HCPEB technique will become a new method for the rapid synthesis of surface porous materials.%The mechanism of micropores formed on the surface of polycrystalline pure aluminum under high-current pulsed electron beam (HCPEB) irradiation is explained.It is discovered that dispersed micropores with sizes of 0.1-1μm on the irradiated surface of pure aluminum can be successfully fabricated after HCPEB irradiation.The dominant formation mechanism of the surface micropores should be attributed to the formation of supersaturation vacancies within the near surface during the HCPEB irradiation and the migration of vacancies along grain boundaries and/or dislocations towards the irradiated surface.It is expected that the HCPEB technique will become a new method for the rapid synthesis of surface porous materials.High-current pulsed electron beams (HCPEBs)have attracted much attention in the field of material surface modification.[1-7] During the transient bombardment process a high energy (108-109 W·cm-2) is deposited only in a very thin layer (less than tens of micrometers) within a very short time (a few microseconds) and thereby causes ultrafast heating and cooling on the irradiated surface of materials.The dynamic stress fields induced in these processes can induce intense deformation on the material surface.

  9. NASA SCaN Overview and Ka-Band Actvities

    Science.gov (United States)

    Stegeman, James D.; Midon, Marco Mario; Davarian, Faramaz; Geldzahler, Barry

    2014-01-01

    The Ka- and Broadband Communications Conference is an international forum attended by worldwide experts in the area of Ka-Band Propagation and satellite communications. Since its inception, NASA has taken the initiative of organizing and leading technical sections on RF Propagation and satellite communications, solidifying its worldwide leadership in the aforementioned areas. Consequently, participation in this conference through the contributions described below will maintain NASA leadership in Ka- and above RF Propagation as it relates to enhancing current and future satellite communication systems supporting space exploration.

  10. Comparison of atmospheric air plasmas excited by high-voltage nanosecond pulsed discharge and sinusoidal alternating current discharge

    Science.gov (United States)

    Zhang, Shuai; Wang, Wen-chun; Jiang, Peng-chao; Yang, De-zheng; Jia, Li; Wang, Sen

    2013-10-01

    In this paper, atmospheric pressure air discharge plasma in quartz tube is excited by 15 ns high-voltage nanosecond pulsed discharge (HVNPD) and sinusoidal alternating current discharge (SACD), respectively, and a comparison study of these two kinds of discharges is made through visual imaging, electrical characterization, optical detection of active species, and plasma gas temperature. The peak voltage of the power supplies is kept at 16 kV while the pulse repetition rate of nanosecond pulse power supply is 100 Hz, and the frequency of sinusoidal power supply is 10 kHz. Results show that the HVNPD is uniform while the SACD presents filamentary mode. For exciting the same cycles of discharge, the average energy consumption in HVNPD is about 1/13 of the SACD. However, the chemical active species generated by the HVNPD is about 2-9 times than that excited by the SACD. Meanwhile, the rotational and vibrational temperatures have been obtained via fitting the simulated spectrum of N2 (C3Πu → B3Πg, 0-2) with the measured one, and the results show that the plasma gas temperature in the HVNPD remains close to room temperature whereas the plasma gas temperature in the SACD is about 200 K higher than that in HVNPD in the initial phase and continually increases as discharge exposure time goes on.

  11. Influence of Surface Resistivity and Temperature on Variation with Time of Current Pulses in Air at Optimum Pressure

    Directory of Open Access Journals (Sweden)

    S.G. Pimpale

    1977-04-01

    Full Text Available The variation of discharge current pulses with the surface nature of electrodes has been investigated by producing discharge in the intense ionizing zone of two ozonizers (A&B containing pure, dry air at a pressure of 4 & 10mm of mercury respectively. The course of reaction in the tube A showed that the periodic rise and fall of discharge counts through a series of recurrences whose amplitude varied randomly. During this reaction, steady potential, temperature of the electrolytic bath, counting time and pulse height were kept fixed. The phenomenon obtained for both the tubes is produced within a critical range of conditions. The results have been interpreted on the basis of activated adsorption at a temperature of 90 degree and 100 degree Centigrade and discussed on the theoretical grounds of change of surface resistivity upon the glass walls. Use of different coatings on annular surface in the same system with appropriate levels of electrolytic solution for a definite value of height-pulses and temperature, etc. shows significant variations in the discharge counts.

  12. WC/Co composite surface structure and nano graphite precipitate induced by high current pulsed electron beam irradiation

    Science.gov (United States)

    Hao, S. Z.; Zhang, Y.; Xu, Y.; Gey, N.; Grosdidier, T.; Dong, C.

    2013-11-01

    High current pulsed electron beam (HCPEB) irradiation was conducted on a WC-6% Co hard alloy with accelerating voltage of 27 kV and pulse duration of 2.5 μs. The surface phase structure was examined by using glancing-angle X-ray diffraction (GAXRD), scanning electron microscope (SEM) and high resolution transmission electron microscope (HRTEM) methods. The surface tribological properties were measured. It was found that after 20 pulses of HCPEB irradiation, the surface structure of WC/Co hard alloy was modified dramatically and composed of a mixture of nano-grained WC1-x, Co3W9C4, Co3W3C phases and graphite precipitate domains ˜50 nm. The friction coefficient of modified surface decreased to ˜0.38 from 0.6 of the initial state, and the wear rate reduced from 8.4 × 10-5 mm3/min to 6.3 × 10-6 mm3/min, showing a significant self-lubricating effect.

  13. Evolution of the current system during solar wind pressure pulses based on aurora and magnetometer observations

    Science.gov (United States)

    Nishimura, Yukitoshi; Kikuchi, Takashi; Ebihara, Yusuke; Yoshikawa, Akimasa; Imajo, Shun; Li, Wen; Utada, Hisashi

    2016-08-01

    We investigated evolution of ionospheric currents during sudden commencements using a ground magnetometer network in conjunction with an all-sky imager, which has the advantage of locating field-aligned currents much more accurately than ground magnetometers. Preliminary (PI) and main (MI) impulse currents showed two-cell patterns propagating antisunward, particularly during a southward interplanetary magnetic field (IMF). Although this overall pattern is consistent with the Araki (solar wind sources of magnetospheric ultra-low-frequency waves. Geophysical monograph series, vol 81. AGU, Washington, DC, pp 183-200, 1994. doi: 10.1029/GM081p0183) model, we found several interesting features. The PI and MI currents in some events were highly asymmetric with respect to the noon-midnight meridian; the post-noon sector did not show any notable PI signal, but only had an MI starting earlier than the pre-noon MI. Not only equivalent currents but also aurora and equatorial magnetometer data supported the much weaker PI response. We suggest that interplanetary shocks impacting away from the subsolar point caused the asymmetric current pattern. Additionally, even when PI currents form in both pre- and post-noon sectors, they can initiate and disappear at different timings. The PI currents did not immediately disappear but coexisted with the MI currents for the first few minutes of the MI. During a southward IMF, the MI currents formed equatorward of a preexisting DP-2, indicating that the MI currents are a separate structure from a preexisting DP-2. In contrast, the MI currents under a northward IMF were essentially an intensification of a preexisting DP-2. The magnetometer and imager combination has been shown to be a powerful means for tracing evolution of ionospheric currents, and we showed various types of ionospheric responses under different upstream conditions.

  14. In-situ calibration of pulsed eddy current detection of cracks at fasteners in CP-140 aircraft

    Science.gov (United States)

    Underhill, Ross; Stott, Colette; Krause, Thomas W.

    2016-02-01

    The use of the Smallest Half Volume (SHV) robust statistics method and the Mahalanobis distance to blindly distinguish fasteners with cracks from fasteners without is examined. Pulsed eddy current data obtained from CP140 Aurora wing structures is used to test the approach. It is shown that the method can achieve levels of detection very close to those obtained when the same measurement technique is applied with full knowledge of which fasteners have no cracks. The method is applicable to a broad range of similar situations when an objective hit/miss criterion is used.

  15. Influence of gas pressure on electron beam emission current of pulsed cathodic-arc-based forevacuum plasma electron source

    Science.gov (United States)

    Burdovitsin, Victor A.; Kazakov, Andrey V.; Medovnik, Alexander V.; Oks, Efim M.

    2017-09-01

    We describe our experimental investigation of the effect of background gas pressure on the emission parameters of a pulsed cathodic-arc-based forevacuum-pressure plasma-cathode electron source. We find that increased gas pressure over the range 4-16 Pa significantly reduces the beam current rise-time and significantly increases the emission current amplitude. For example, at a discharge current of 20 A, increasing the working gas pressure from 4 Pa to 16 Pa increases the emission current from 8 A to 18 A and shortens the beam rise-time from 50 μs to 20 μs. This influence of gas pressure on the electron beam parameters can be explained by the effect of arc discharge current switching from the anode to emission. In our case, the current switching effect is caused by increased working gas pressure. In the forevacuum pressure range, the increase of the electron emission current with the growth of gas pressure is due to a rise in the emission plasma potential which is caused by ion back-streaming from the plasma formed in the electron beam transport region. A model describing the influence of gas pressure on the electron emission from the plasma is presented.

  16. Evidence for breathing modes in direct current, pulsed, and high power impulse magnetron sputtering plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuchen [State Key Lab for Materials Processing and Die & Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States); Zhou, Xue [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States); Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150000 (China); Liu, Jason X. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States); Department of Physics, University of California, Berkeley, Berkeley, California 94720 (United States); Anders, André, E-mail: aanders@lbl.gov [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2016-01-18

    We present evidence for breathing modes in magnetron sputtering plasmas: periodic axial variations of plasma parameters with characteristic frequencies between 10 and 100 kHz. A set of azimuthally distributed probes shows synchronous oscillations of the floating potential. They appear most clearly when considering the intermediate current regime in which the direction of azimuthal spoke motion changes. Breathing oscillations were found to be superimposed on azimuthal spoke motion. Depending on pressure and current, one can also find a regime of chaotic fluctuations and one of stable discharges, the latter at high current. A pressure-current phase diagram for the different situations is proposed.

  17. Experimental investigation of electron beam wave interactions utilising short pulses

    CERN Document Server

    Wiggins, S M

    2000-01-01

    Experiments have investigated the production of ultra-short electromagnetic pulses and their interaction with electrons in various resonant structures. Diagnostic systems used in the measurements included large bandwidth detection systems for capturing the short pulses. Deconvolution techniques have been applied to account for bandwidth limitation of the detection systems and to extract the actual pulse amplitudes and durations from the data. A Martin-Puplett interferometer has been constructed for use as a Fourier transform spectrometer. The growth of superradiant electromagnetic spikes from short duration (0.5-1.0 ns), high current (0.6-2.0 kA) electron pulses has been investigated in a Ka-band Cherenkov maser and Ka- and W-band backward wave oscillators (BWO). In the Cherenkov maser, radiation spikes were produced with a peak power = 70 ps and a bandwidth <= 19 %. It is shown that coherent spontaneous emission from the leading edge of the electron pulse drives these interactions, giving rise to self-amp...

  18. DARHT-II Long-Pulse Beam-Dynamics Experiments

    CERN Document Server

    Ekdahl, Carl; Bartsch, Richard; Bender, Howard; Briggs, Richard J; Broste, William; Carlson, Carl; Caudill, Larry; Chan, Kwok-Chi D; Chen Yu Jiuan; Dalmas, Dale; Durtschi, Grant; Eversole, Steven; Eylon, Shmuel; Fawley, William M; Frayer, Daniel; Gallegos, Robert J; Harrison, James; Henestroza, Enrique; Holzscheiter, M H; Houck, Timothy L; Hughes, Thomas P; Jacquez, Edward; Johnson, Douglas; Johnson, Jeffrey; Jones, Kenneth; McCuistian, Brian T; Meidinger, Alfred; Montoya, Nicholas; Mostrom, Chris; Moy, Kenneth; Nath, Subrata; Nielsen, Kurt; Oro, David; Rodriguez, Leroy; Rodriguez, Patrick; Rowton, Larry J; Sanchez, Manolito; Scarpetti, Raymond; Schauer, Martin; Schulze, Martin E; Simmons, David; Studebaker, Jan; Sturgess, Ronald; Sullivan, Gary; Swinney, Charles; Tang, Yan; Temple, Rodney; Tipton, Angela; Tom, C Y; Vernon Smith, H; Yu, Simon

    2005-01-01

    When completed, the DARHT-II linear induction accelerator (LIA) will produce a 2-kA, 18-MeV electron beam with more than 1500-ns current/energy "flat-top." In initial tests DARHT-II has already accelerated beams with current pulse lengths from 500-ns to 1200-ns full-width at half maximum (FWHM) with more than1.2-kA, 12.5-MeV peak current and energy. Experiments are now underway with a ~2000-ns pulse length, but reduced current and energy. These pulse lengths are all significantly longer than any other multi-MeV LIA, and they define a novel regime for high-current beam dynamics, especially with regard to beam stability. Although the initial tests demonstrated absence of BBU, the pulse lengths were too short to test the predicted protection against ion-hose instability. The present experiments are designed to resolve these and other beam-dynamics issues with a ~2000-ns pulse length beam.

  19. Influence of deposited energy on shock wave induced by underwater pulsed current discharge

    Science.gov (United States)

    Li, Xian-Dong; Liu, Yi; Liu, Si-Wei; Li, Zhi-Yuan; Zhou, Gu-Yue; Li, Hua; Lin, Fu-Chang; Pan, Yuan

    2016-10-01

    In this paper, an integrated experimental system is established to study the influence of deposited energy on the intensity of the shock wave induced by underwater pulse discharge. Considering the time varying behavior of the arc, the calculation methods of the deposited energy into the plasma channel and the average arc resistance are proposed and presented. The effect of the breakdown process on the deposited energy and the shock wave is analyzed. It can be concluded that the shock wave intensity can be improved by depositing more energy in the first half oscillation period and increasing the arc resistance. It is also found that the energy deposition and the shock wave intensity are significantly influenced by the breakdown time delay and the shape of the initial plasma channel.

  20. Current regimen of pulse therapy for pemphigus: Minor modifications, improved results

    Directory of Open Access Journals (Sweden)

    Pasricha J

    2008-01-01

    Full Text Available Background: If administered properly, dexamethasone cyclophosphamide pulse (DCP therapy has the potential to effect lifelong recovery from pemphigus. Aims: The objective of this paper is to highlight various parameters of DCP therapy and also, to report the effects of a few modifications in the regimen. Methods: An analysis of 123 patients treated with the DCP/DP regimen over a period of five years (1998 to 2002 is presented here. Seventeen patients who did not start/continue the treatment and three patients who died during the treatment have been excluded from the analysis. Twenty patients who had not yet started families were given only dexamethasone pulses (DPs while 103 patients received DCPs. Low dose (50 mg/day cyclophosphamide was used as in the standard regimen. The three modifications introduced into the regimen were: (1 an additional daily dose of oral betamethasone sufficient to control the disease activity during phase I, which was progressively tapered off completely as the patient recovered, (2 use of systemic antibiotics if the patient had skin lesions, and oral anti-candida drugs if the patient had oral ulcers until complete healing, and (3 insistence on thorough cleaning of the skin and scalp with a normal soap and shampoo, and proper maintenance of oral hygiene in spite of skin/mucosal lesions. The regimen consisted of DCP/DP repeated in exactly 28-day cycles, along with 50 mg cyclophosphamide per day, insistence on completing the treatment and avoiding irregular pulses in all patients. The number of DCPs/DPs during phase I varied in different patients depending upon the dose of betamethasone used and the rate of recovery, but phase II (nine DCPs/DPs in exactly 28-day cycles along with 50 mg cyclophosphamide per day and phase III (only 50 mg cyclophosphamide per day was fixed at nine months each. This was followed by posttreatment follow-up (phase IV. Results: At present, all the patients are in complete remission. The

  1. Characteristics of Extra Narrow Gap Weld of HSLA Steel Welded by Single-Seam per Layer Pulse Current GMA Weld Deposition

    Science.gov (United States)

    Agrawal, B. P.; Ghosh, P. K.

    2017-03-01

    Butt weld joints are produced using pulse current gas metal arc welding process by employing the technique of centrally laid multi-pass single-seam per layer weld deposition in extra narrow groove of thick HSLA steel plates. The weld joints are prepared by using different combination of pulse parameters. The selection of parameter of pulse current gas metal arc welding is done considering a summarized influence of simultaneously interacting pulse parameters defined by a dimensionless hypothetical factor ϕ. The effect of diverse pulse parameters on the characteristics of weld has been studied. Weld joint is also prepared by using commonly used multi-pass multi-seam per layer weld deposition in conventional groove. The extra narrow gap weld joints have been found much superior to the weld joint prepared by multi-pass multi-seam per layer deposition in conventional groove with respect to its metallurgical characteristics and mechanical properties.

  2. Comparison of the pulsed MIG welding process for different median current

    Institute of Scientific and Technical Information of China (English)

    Wen Yuanmei; Xue Jiaxiang; Yao Ping; Huang Shisheng

    2009-01-01

    Based on the high speed video system with electrical signals collecting and wavelet analyzing, the welding processes under three different median currents with the same median time were detected. The experimental results show that, when the median current is higher, the input peak energy is lower. And the droplet transfer is almost in spray mode. The welding process is the stablest.

  3. Nanoseconds field emitted current pulses from ZrC needles and field emitter arrays

    CERN Document Server

    Ganter, R; Betemps, R; Dehler, M; Gerber, T; Gobrecht, J; Gough, C; Johnson, M; Kirk, E; Knopp, G; Le Pimpec, F; Li, K; Paraliev, M; Pedrozzi, M; Rivkin, L; Schulz, L; Sehr, H; Wrulich, A F

    2006-01-01

    The properties of the electron source define the ultimate limit of the beam quality in linear accelerators like Free Electron Lasers (FEL). The goal is to develop an electron gun delivering beam emittance lower than current state of the art. Such a gun should reduce the cost and size of an X-ray Free Electron Laser (XFEL). In this paper we present two concepts of field emitter cathodes which could potentially produce low emittance beam. The first challenging parameter for such cathode is to emit peak current as high as 5 A. This is the minimum current requirement for the XFEL concept from Paul Scherrer Institut.1 Maximum current of 0.12 A and 0.58 A have been reached respectively with field emitter arrays (FEA) and single needle cathodes. Laser assisted field emission gave encouraging results to reach even higher peak current and to pre-bunch the beam.

  4. Effect of Inductive Coil Geometry and Current Sheet Trajectory of a Conical Theta Pinch Pulsed Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Bonds, Kevin W.; Emsellem, Gregory D.

    2011-01-01

    Results are presented demonstrating the e ect of inductive coil geometry and current sheet trajectory on the exhaust velocity of propellant in conical theta pinch pulsed induc- tive plasma accelerators. The electromagnetic coupling between the inductive coil of the accelerator and a plasma current sheet is simulated, substituting a conical copper frustum for the plasma. The variation of system inductance as a function of plasma position is obtained by displacing the simulated current sheet from the coil while measuring the total inductance of the coil. Four coils of differing geometries were employed, and the total inductance of each coil was measured as a function of the axial displacement of two sep- arate copper frusta both having the same cone angle and length as the coil but with one compressed to a smaller size relative to the coil. The measured relationship between total coil inductance and current sheet position closes a dynamical circuit model that is used to calculate the resulting current sheet velocity for various coil and current sheet con gura- tions. The results of this model, which neglects the pinching contribution to thrust, radial propellant con nement, and plume divergence, indicate that in a conical theta pinch ge- ometry current sheet pinching is detrimental to thruster performance, reducing the kinetic energy of the exhausting propellant by up to 50% (at the upper bound for the parameter range of the study). The decrease in exhaust velocity was larger for coils and simulated current sheets of smaller half cone angles. An upper bound for the pinching contribution to thrust is estimated for typical operating parameters. Measurements of coil inductance for three di erent current sheet pinching conditions are used to estimate the magnetic pressure as a function of current sheet radial compression. The gas-dynamic contribution to axial acceleration is also estimated and shown to not compensate for the decrease in axial electromagnetic acceleration

  5. Transient interaction model of electromagnetic field generated by lightning current pulses and human body

    Science.gov (United States)

    Iváncsy, T.; Kiss, I.; Szücs, L.; Tamus, Z. Á.

    2015-10-01

    The lightning current generates time-varying magnetic field near the down- conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts. In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated.

  6. Strengthening effect of nano-scaled precipitates in Ta alloying layer induced by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Guangze; Luo, Dian; Fan, Guohua [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Ma, Xinxin, E-mail: maxin@hit.edu.cn [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Wang, Liqin [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2017-05-01

    Highlights: • Ta alloying layer are fabricated by magnetron sputtering and high current pulsed electron beam. • Nano-scaled TaC precipitates forms within the δ-Fe grain after tempering treatment. • The mean diameter of TaC particles is about 5–8 nm. • The hardness of alloying layer increased by over 50% after formation of nano-scaled TaC particle. - Abstract: In this study, the combination of magnetron sputtering and high current pulsed electron beam are used for surface alloying treatment of Ta film on high speed steel. And the Ta alloying layer is about 6 μm. After tempering treatment, TaC phase forms in Ta alloying layer when the treated temperature is over 823 K. Through the TEM and HRTEM observation, a large amount of nano-scaled precipitates (mean diameter 5–8 nm) form within the δ-Fe grain in Ta alloying layer after tempering treatment and these nano-scaled precipitates are confirmed as TaC particles, which contribute to the strengthening effect of the surface alloying layer. The hardness of tempered alloying layer can reach to 18.1 GPa when the treated temperature is 823 K which increase by 50% comparing with the untreated steel sample before surface alloying treatment.

  7. Inverse spin Hall effect from pulsed spin current in organic semiconductors with tunable spin-orbit coupling.

    Science.gov (United States)

    Sun, Dali; van Schooten, Kipp J; Kavand, Marzieh; Malissa, Hans; Zhang, Chuang; Groesbeck, Matthew; Boehme, Christoph; Valy Vardeny, Z

    2016-08-01

    Exploration of spin currents in organic semiconductors (OSECs) induced by resonant microwave absorption in ferromagnetic substrates is appealing for potential spintronics applications. Owing to the inherently weak spin-orbit coupling (SOC) of OSECs, their inverse spin Hall effect (ISHE) response is very subtle; limited by the microwave power applicable under continuous-wave (cw) excitation. Here we introduce a novel approach for generating significant ISHE signals in OSECs using pulsed ferromagnetic resonance, where the ISHE is two to three orders of magnitude larger compared to cw excitation. This strong ISHE enables us to investigate a variety of OSECs ranging from π-conjugated polymers with strong SOC that contain intrachain platinum atoms, to weak SOC polymers, to C60 films, where the SOC is predominantly caused by the curvature of the molecule's surface. The pulsed-ISHE technique offers a robust route for efficient injection and detection schemes of spin currents at room temperature, and paves the way for spin orbitronics in plastic materials.

  8. Inverse spin Hall effect from pulsed spin current in organic semiconductors with tunable spin-orbit coupling

    Science.gov (United States)

    Sun, Dali; van Schooten, Kipp J.; Kavand, Marzieh; Malissa, Hans; Zhang, Chuang; Groesbeck, Matthew; Boehme, Christoph; Valy Vardeny, Z.

    2016-08-01

    Exploration of spin currents in organic semiconductors (OSECs) induced by resonant microwave absorption in ferromagnetic substrates is appealing for potential spintronics applications. Owing to the inherently weak spin-orbit coupling (SOC) of OSECs, their inverse spin Hall effect (ISHE) response is very subtle; limited by the microwave power applicable under continuous-wave (cw) excitation. Here we introduce a novel approach for generating significant ISHE signals in OSECs using pulsed ferromagnetic resonance, where the ISHE is two to three orders of magnitude larger compared to cw excitation. This strong ISHE enables us to investigate a variety of OSECs ranging from π-conjugated polymers with strong SOC that contain intrachain platinum atoms, to weak SOC polymers, to C60 films, where the SOC is predominantly caused by the curvature of the molecule’s surface. The pulsed-ISHE technique offers a robust route for efficient injection and detection schemes of spin currents at room temperature, and paves the way for spin orbitronics in plastic materials.

  9. High-temperature performance of MoS{sub 2} thin-film transistors: Direct current and pulse current-voltage characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, C.; Samnakay, R.; Balandin, A. A., E-mail: balandin@ee.ucr.edu [Nano-Device Laboratory (NDL), Department of Electrical Engineering, Bourns College of Engineering, University of California—Riverside, Riverside, California 92521 (United States); Phonon Optimized Engineered Materials (POEM) Center, Materials Science and Engineering Program, University of California—Riverside, Riverside, California 92521 (United States); Rumyantsev, S. L. [Department of Electrical, Computer, and Systems Engineering, Center for Integrated Electronics, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Ioffe Physical-Technical Institute, St. Petersburg 194021 (Russian Federation); Shur, M. S. [Department of Electrical, Computer, and Systems Engineering, Center for Integrated Electronics, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2015-02-14

    We report on fabrication of MoS{sub 2} thin-film transistors (TFTs) and experimental investigations of their high-temperature current-voltage characteristics. The measurements show that MoS{sub 2} devices remain functional to temperatures of at least as high as 500 K. The temperature increase results in decreased threshold voltage and mobility. The comparison of the direct current (DC) and pulse measurements shows that the direct current sub-linear and super-linear output characteristics of MoS{sub 2} thin-films devices result from the Joule heating and the interplay of the threshold voltage and mobility temperature dependences. At temperatures above 450 K, a kink in the drain current occurs at zero gate voltage irrespective of the threshold voltage value. This intriguing phenomenon, referred to as a “memory step,” was attributed to the slow relaxation processes in thin films similar to those in graphene and electron glasses. The fabricated MoS{sub 2} thin-film transistors demonstrated stable operation after two months of aging. The obtained results suggest new applications for MoS{sub 2} thin-film transistors in extreme-temperature electronics and sensors.

  10. Finite element modeling of wall-loss sizing in a steam generator tube using a pulsed eddy current probe

    Science.gov (United States)

    Babbar, V. K.; Lepine, B.; Buck, J.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2015-03-01

    Inspection of steam generator (SG) tubes by conventional eddy current may, in general, involve analysis of indications from volumetric wall loss, cracks, fouling and support-plate degradation; however, it may be difficult to size or quantify effects from support-to-tube gap and tube tilt, especially in the presence of support plates. Pulsed eddy current (PEC) technology is being developed to investigate such complex tube and flaw geometries. The present work employs finite element modeling to investigate the effectiveness of PEC in identifying and sizing the outer diameter wall-loss in SG tubes. The signals analyzed using a modified principal components analysis (PCA) method reveal the potential success of a PEC-PCA combination to produce scores that can be used to size the wall-loss in the presence of support plates. The modeling results are in good agreement with experimental observations.

  11. Norwegian Sea warm pulses during Dansgaard-Oeschger stadials: Zooming in on these anomalies over the 35-41 ka cal BP interval and their impacts on proximal European ice-sheet dynamics

    Science.gov (United States)

    Wary, Mélanie; Eynaud, Frédérique; Rossignol, Linda; Lapuyade, Joanna; Gasparotto, Marie-Camille; Londeix, Laurent; Malaizé, Bruno; Castéra, Marie-Hélène; Charlier, Karine

    2016-11-01

    The last glacial millennial climatic events (i.e. Dansgaard-Oeschger and Heinrich events) constitute outstanding case studies of coupled atmosphere-ocean-cryosphere interactions. Here, we investigate the evolution of sea-surface and subsurface conditions, in terms of temperature, salinity and sea ice cover, at very high-resolution (mean resolution between 55 and 155 years depending on proxies) during the 35-41 ka cal BP interval covering three Dansgaard-Oeschger cycles and including Heinrich event 4, in a new unpublished marine record, i.e. the MD99-2285 core (62.69°N; -3.57s°E). We use a large panel of complementary tools, which notably includes dinocyst-derived sea-ice cover duration quantifications. The high temporal resolution and multiproxy approach of this work allows us to identify the sequence of processes and to assess ocean-cryosphere interactions occurring during these periodic ice-sheet collapse events. Our results evidence a paradoxical hydrological scheme where (i) Greenland interstadials are marked by a homogeneous and cold upper water column, with intensive winter sea ice formation and summer sea ice melting, and (ii) Greenland and Heinrich stadials are characterized by a very warm and low saline surface layer with iceberg calving and reduced sea ice formation, separated by a strong halocline from a less warm and saltier subsurface layer. Our work also suggests that this stadial surface/subsurface warming started before massive iceberg release, in relation with warm Atlantic water advection. These findings thus support the theory that upper ocean warming might have triggered European ice-sheet destabilization. Besides, previous paleoceanographic studies conducted along the Atlantic inflow pathways close to the edge of European ice-sheets suggest that such a feature might have occurred in this whole area. Nonetheless, additional high resolution paleoreconstructions are required to confirm such a regional scheme.

  12. A high current sinusoidal pulse generator for the diluter magnets of the LHC beam dump system

    CERN Document Server

    Vossenberg, Eugène B; Ducimetière, L; Schröder, G H

    2000-01-01

    CERN is constructing the Large Hadron Collider (LHC), a superconducting accelerator that will collide protons at a center of mass energy of 14 TeV. The two colliding beams will each store an energy of up to 540 MJ, which must be safely deposited within one beam revolution of 89 mu s on two external absorbers located about 700 m from the extraction points at the end of dedicated extraction tunnels. To avoid evaporation of the graphite absorber material by the very high energy density of the incident beams, the deposition area of the beams on the absorber front face will be increased. This is done by a pair of sinusoidally powered orthogonal magnet systems producing approximately an e-shape figure of about 35 mm diameter, with a minimum velocity of 10 mm/ mu s during the dumping process. The pulse generators of the horizontally and vertically deflecting diluter magnets are composed of capacitor banks, discharged by stacks of solid state closing switches. They are connected to the magnets by 28 m long low induct...

  13. 脉冲涡流信号检测与分析%Pulsed Eddy Current Signal Detection and Analysis

    Institute of Scientific and Technical Information of China (English)

    杨理践; 李春华; 裴磊

    2013-01-01

    为了对较厚钢板进行缺陷检测,采用对低压大功率的电源进行斩波的方式产生大电流脉冲,设计圆柱形探头,采用激励线圈缓慢放电的方式检测钢板表面缺陷;设计矩形探头,采用激励线圈瞬间放电的方式检测钢板亚表面;对脉冲涡流瞬态感应电压信号进行小波滤噪和幅值归一化处理.实验结果表明,小波滤噪可以提高检测精度,对信号幅值进行归一化处理可以更直接地反映不同深度缺陷产生的曲线间的相互关系,大电流激励的脉冲涡流信号幅值能反映较厚钢板表面和亚表面缺陷深度.%In order to detect the defects on thicker steel plate,a high—current pulse was needed,which was generated by chopping the low—voltage high power supply.Moreover,cylindrical probe was designed to detect surface defects of steel plate by slow discharging of exciting coil; rectangular probe was also designed to detect sub—surface defects of steel plate by instant discharging of exciting coil.Then the transient induced voltage signal of pulsed eddy current was processed by the wavelet filtering and amplitude normalization.Experimental results show that the wavelet filtering can improve detecting accuracy and the signals amplitude normalized can reflect the relationship of the defect curves at different depths defects more directly.It is concluded that amplitude of high pulsed eddy current signal excited by high—current can reflect the depths of defects on surface and sub—surface of thicker steel plate effectively.

  14. Health effects of electromagnetic field generated by lightning current pulses near down conductors

    Science.gov (United States)

    Tamus, Z. Á.; Novák, B.; Szücs, L.; Kiss, I.

    2011-06-01

    The lightning current generates a time varying magnetic field near down conductors, when lightning strikes the connected Franklin-rod. The down conductors are mounted on the wall of buildings, where residential places can be situated. It is well known that the rapidly changing magnetic fields could generate dangerous eddy currents in the human body. If the duration and the gradient of the magnetic field were high enough, the peripheral nerves are excited. In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near a down conductor with the human body. The interaction model has two parts: estimation of the magnetic fields surrounding the down conductor and evaluation of health effects of rapid changing magnetic fields on the human body.

  15. A novel biphasic-current-pulse calibration technique for electrical neural stimulation.

    Science.gov (United States)

    Maohua Ren; Jinyong Zhang; Lei Wang; Zhenyu Wang

    2014-01-01

    One of the major challenge in neural prosthetic device design is to ensure charge-balanced stimulation. This paper presents a new calibration technique to minimize the mismatch between anodic and cathodic current amplitudes. The proposed circuit mainly consists of a digital and an analog calibration, where a successive approximation register (SAR) logic and a comparator are used in digital calibration while a source follower is adopted in analog calibration. With a 0.18 μm high voltage CMOS process, the simulation shows that the maximum current mismatch is 45 nA (<0.05%).

  16. Optimization of the pulsed current gas tungsten arc welding (PCGTAW) parameters for corrosion resistance of super duplex stainless steel (UNS S32760) welds using the Taguchi method

    Energy Technology Data Exchange (ETDEWEB)

    Yousefieh, M., E-mail: m.yousefieh@ma.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Shamanian, M., E-mail: shamanian@cc.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Saatchi, A. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2011-01-21

    Research highlights: > Among the four factors and three levels tested, it was concluded that the pulse current had the most significant effect on the pitting potential and the background current had the next most significant effect. The effects of pulse frequency and % on time are less important when compared to the other factors. > The percentage contributions of the pulse current, the background current, % on time, and pulse frequency to the corrosion resistance are 66.28%, 25.97%, 2.71% and 5.04%, respectively. > The optimum conditions within the selected parameter values were found as the second level of pulse current (120 A), second level of background current (60 A), third level of % on time (80%) and third level of pulse frequency (5 Hz). > The confirmation test was carried out at optimum working conditions. Pitting potential was increased to 1.06 V{sub SCE} by setting the control factors. Predicted (1.04 V{sub SCE}) and observed (1.06 V{sub SCE}) pitting potential values are close to each other, which are the highest values obtained in the present study. - Abstract: In the present work, a design of experiment (DOE) technique, the Taguchi method, has been used to optimize the pulsed current gas tungsten arc welding (PCGTAW) parameters for the corrosion resistance of super duplex stainless steel (UNS S32760) welds. A L{sub 9} (3{sup 4}) orthogonal array (OA) of Taguchi design which involves nine experiments for four parameters (pulse current, background current, % on time, pulse frequency) with three levels was used. Corrosion resistance in 3.5%NaCl solution was evaluated by anodic polarization tests at room temperature. Analysis of variance (ANOVA) is performed on the measured data and S/N (signal to noise) ratios. The higher the better response category was selected to obtain optimum conditions. The optimum conditions providing the highest pitting potential were estimated. The optimum conditions were found as the second level of pulse current (120 A

  17. Effect of Continuous and Pulsed Current Gas Tungsten Arc Welding on Dissimilar Weldments Between Hastelloy C-276/AISI 321 Austenitic Stainless Steel

    Science.gov (United States)

    Sharma, Sumitra; Taiwade, Ravindra V.; Vashishtha, Himanshu

    2017-03-01

    In the present investigation, an attempt has been made to join Hastelloy C-276 nickel-based superalloy and AISI 321 austenitic stainless steel using ERNiCrMo-4 filler. The joints were fabricated by continuous and pulsed current gas tungsten arc welding processes. Experimental studies to ascertain the structure-property co-relationship with or without pulsed current mode were carried out using an optical microscope and scanning electron microscope. Further, the energy-dispersive spectroscope was used to evaluate the extent of microsegregation. The microstructure of fusion zone was obtained as finer cellular dendritic structure for pulsed current mode, whereas columnar structure was formed with small amount of cellular structure for continuous current mode. The scanning electron microscope examination witnessed the existence of migrated grain boundaries at the weld interfaces. Moreover, the presence of secondary phases such as P and μ was observed in continuous current weld joints, whereas they were absent in pulsed current weld joints, which needs to be further characterized. Moreover, pulsed current joints resulted in narrower weld bead, refined morphology, reduced elemental segregation and improved strength of the welded joints. The outcomes of the present investigation would help in obtaining good quality dissimilar joints for industrial applications and AISI 321 ASS being cheaper consequently led to cost-effective design also.

  18. Effect of Continuous and Pulsed Current Gas Tungsten Arc Welding on Dissimilar Weldments Between Hastelloy C-276/AISI 321 Austenitic Stainless Steel

    Science.gov (United States)

    Sharma, Sumitra; Taiwade, Ravindra V.; Vashishtha, Himanshu

    2017-02-01

    In the present investigation, an attempt has been made to join Hastelloy C-276 nickel-based superalloy and AISI 321 austenitic stainless steel using ERNiCrMo-4 filler. The joints were fabricated by continuous and pulsed current gas tungsten arc welding processes. Experimental studies to ascertain the structure-property co-relationship with or without pulsed current mode were carried out using an optical microscope and scanning electron microscope. Further, the energy-dispersive spectroscope was used to evaluate the extent of microsegregation. The microstructure of fusion zone was obtained as finer cellular dendritic structure for pulsed current mode, whereas columnar structure was formed with small amount of cellular structure for continuous current mode. The scanning electron microscope examination witnessed the existence of migrated grain boundaries at the weld interfaces. Moreover, the presence of secondary phases such as P and μ was observed in continuous current weld joints, whereas they were absent in pulsed current weld joints, which needs to be further characterized. Moreover, pulsed current joints resulted in narrower weld bead, refined morphology, reduced elemental segregation and improved strength of the welded joints. The outcomes of the present investigation would help in obtaining good quality dissimilar joints for industrial applications and AISI 321 ASS being cheaper consequently led to cost-effective design also.

  19. Prunskiene tahab lepet ka Keskerakonnaga

    Index Scriptorium Estoniae

    2011-01-01

    Leedu Rahvaerakonna (LLP) juht Kazimira Prunskeine käis Moskvas Ühtse Venemaa kongressil ning allkirjastas leppe oma erakonna ja Ühtse Venemaa vahel, samasuguse leppe kavatseb ta allkirjastada ka Eesti Keskerakonnaga, Kasahstanis võimul oleva Nur Otani partei ja Kreeka erakonnaga Uus Demokraatia

  20. Ajateenistust alustab ka viis neidu

    Index Scriptorium Estoniae

    2013-01-01

    Tuleval nädalal alustab ajateenistust üle 1600 noormehe, lisaks alustab juulis Kuperjanovi jala­väepataljonis vabatahtlikuna ajateenistust ka viis neidu. Juulikuise teenistusse kutsumisega alustavad teenistust ajateenijad, kelle ametikoht eeldab 11-kuulist ajateenistust ehk autojuhid, erialaspet­sialistid, allohvitserid ja reservrühmaülemad

  1. Current Density Limitations in a Fast-Pulsed High-Voltage Diode

    Science.gov (United States)

    1992-06-01

    based on mass x acceleration - charge x E-field) - - -= qT (x)=-e rT(X) (19) dt M c M c where y ,ŕ /•/ 2/c ••V/c; t * time (S) e I electron charge I... Plasmaphysik IPP 4/250, September 1991. 6. Parker, R.K., Explosive Electron Emission and the Characteristics of High-Current Electron Flow, Air Force

  2. Temporally Shaped Current Pulses on a Two-Cavity Linear Transformer Driver System

    Science.gov (United States)

    2011-06-01

    system was triggered. The digitizers were triggered by a reference voltage divider from a 20 kV thyratron pulser, which also triggers the master high...measured from the calibrated voltage and current monitors. The simulations use the Martin [15] arc discharge switch resistance model . The gas...switches use dry air at 3 bar pressure; the gas type, pressure, and gap are all used in the switch model to calculate self-consistently the dynamic

  3. Surface textured molybdenum doped zinc oxide thin films prepared for thin film solar cells using pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Y.C., E-mail: ielinyc@cc.ncue.edu.tw; Wang, B.L.; Yen, W.T.; Shen, C.H.

    2011-06-01

    In this study, we examined the effect of etching on the electrical properties, transmittance, and scattering of visible light in molybdenum doped zinc oxide, ZnO:Mo (MZO) thin films prepared by pulsed direct current magnetron sputtering. We used two different etching solutions - KOH and HCl - to alter the surface texture of the MZO thin film so that it could trap light. The experimental results showed that an MZO film with a minimum resistivity of about 8.9 x 10{sup -4} {Omega} cm and visible light transitivity of greater than 80% can be obtained without heating at a Mo content of 1.77 wt.%, sputtering power of 100 W, working pressure of 0.4 Pa, pulsed frequency of 10 kHz, and film thickness of 500 nm. To consider the effect of resistivity and optical diffuse transmittance, we performed etching of an 800 nm thick MZO thin film with 0.5 wt.% HCl for 3-6 s at 300 K. Consequently, we obtained a resistivity of 1.74-2.75 x 10{sup -3} {Omega} cm, total transmittance at visible light of 67%-73%, diffuse transmittance at visible light of 25.1%-28.4%, haze value of 0.34-0.42, and thin film surface crater diameters of 220-350 nm.

  4. Grain refinement, hardening and metastable phase formation by high current pulsed electron beam (HCPEB) treatment under heating and melting modes

    Energy Technology Data Exchange (ETDEWEB)

    Grosdidier, T., E-mail: Thierry.grosdidier@univ-metz.f [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, CNRS 3143), Universite Paul Verlaine-Metz, Ile du Saulcy, 57045 Metz (France); Lab of Materials Modification by Laser, Ion and Electron Beams and School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Zou, J.X. [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, CNRS 3143), Universite Paul Verlaine-Metz, Ile du Saulcy, 57045 Metz (France); Bolle, B. [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, CNRS 3143), ENIM, Ile du Saulcy, 57045 Metz (France); Hao, S.Z.; Dong, C. [Lab of Materials Modification by Laser, Ion and Electron Beams and School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China)

    2010-08-15

    High current pulsed electron beam is a recently developed technique for surface modification. The pulsed electron irradiation introduces concentrated energy depositions in the thin surface layer of the treated materials, giving rise to an extremely fast heating and subsequent rapid cooling of the surface together with the formation of dynamic stress waves. Improved surface properties (hardness, corrosion resistance) can be obtained under the 'melting' mode when the top surface is melted and rapidly solidified (10{sup 7} K/s). In steels, this is essentially the result of nanostructures formed from the highly undercooled melt, melt surface purification, strain hardening induced by the thermal stress waves as well as metastable phase selections in the rapidly solidified melted layers. The use of the 'heating' mode is less conventional, combining effects of the heavy deformation and recrystallization/recovery mechanisms. A detailed analysis of a FeAl alloy demonstrates grain size refinement, hardening, solid-state enhanced diffusion and texture modification without modification of the surface geometry.

  5. Schlieren study of a sonic jet injected into a supersonic cross flow using high-current pulsed LEDs

    CERN Document Server

    Giskes, Ella; Segerink, Frans B; Venner, Cornelis H

    2016-01-01

    In the research of supersonic flows, flow visualization continues to be an important tool, and even today it is difficult to create high quality images. In this study we present a low-cost and easy-to use Schlieren setup. The setup makes use of LEDs, pulsed with high currents to increase the optical output to sufficient levels, exploiting the advantages of LED light over conventional light sources. As a test-case we study the interaction of a Mach 1.7 cross flow and a transverse underexpanded jet, which is commonly studied considering the mixing and combustion in scramjet engines. Using 130 nanosecond LED light pulses, we captured the flow structures sharply and in great detail. We observed a large-gradient wave, which was seen in numerical studies but hitherto not reported in experiments. Furthermore, we demonstrate that time-correlated images can be obtained with this Schlieren setup, so that also flow unsteadiness can be studied, such as the movement of shock waves and vortices.

  6. Electric pulse current stimulation increases electrophysiological properties of If current reconstructed in mHCN4-transfected canine mesenchymal stem cells.

    Science.gov (United States)

    Feng, Yuanyuan; Luo, Shouming; Yang, Pan; Song, Zhiyuan

    2016-04-01

    The 'funny' current, also known as the If current, play a crucial role in the spontaneous diastolic depolarization of sinoatrial node cells. The If current is primarily induced by the protein encoded by the hyperpolarization-activated cyclic nucleotide-gated channel 4 (HCN4) gene. The functional If channel can be reconstructed in canine mesenchymal stem cells (cMSCs) transfected with mouse HCN4 (mHCN4). Biomimetic studies have shown that electric pulse current stimulation (EPCS) can promote cardiogenesis in cMSCs. However, whether EPCS is able to influence the properties of the If current reconstructed in mHCN4-transfected cMSCs remains unclear. The present study aimed to investigate the effects of EPCS on the If current reconstructed in mHCN4-transfected cMSCs. The cMSCs were transfected with the lentiviral vector pLentis-mHCN4-GFP. Following transfection, these cells were divided into two groups: mHCN4-transfected cMSCs (group A), and mHCN4-transfected cMSCs induced by EPCS (group B). Using a whole cell patch-clamp technique, the If current was recorded, and group A cMSCs showed significant time and voltage dependencies and sensitivity to extracellular Cs+. The half-maximal activation (V1/2) value was -101.2±4.6 mV and the time constant of activation was 324±41 msec under -160 mV. In the group B cells the If current increased obviously and activation curve moved to right. The absolute value of V1/2 increased significantly to -92.4±4.8 mV (P<0.05), and the time constant of activation diminished under the same command voltage (251±44 vs. 324±41, P<0.05). In addition, the mRNA and protein expression levels of HCN4, connexin 43 (Cx43) and Cx45 were upregulated in group B compared with group A, as determined by reverse transcription-quantitative polymerase chain reaction and western blot analyses. Transmission electron micrographs also confirmed the increased gap junctions in group B. Collectively, these results indicated that reconstructed If channels may have a

  7. Theoretical and experimental study of superradiance pulse generation by heavy-current subnanosecond electron bunches moving in periodic slowing down system

    CERN Document Server

    Ginzburg, N S; Novozhilova, Y V; Sergeev, A S; Shpak, V G; Shunailov, S A; Ul'maskulov, M R; Yalandin, M I

    2002-01-01

    One studied both theoretically and experimentally the Cherenkov superradiance at liner motion of an electron bunch through the periodic slowing down system. Simulations in terms of the KARAT code show that peak intensity of microwave pulses is proportional to the square of total number of particles in a bunch. This finding os conformed experimentally. As a results, at 39 GHz frequency one obtained ultrashort pulses of up to 140 MW high intensity and with 30 ps duration. The RADAN 303 high-current subnanosecond accelerator injected electron bunches with up to 2 A current, 0.5-1.5 ns duration and 200-300 keV particle energy was used as a source of electrons. Simulation shows possibility of further intensification of electromagnetic pulses up to 300-400 MW due to optimization of parameters of accelerating voltage pulse

  8. Improvement of Wear Resistance of Magnesium Alloy AZ91HP by High Current Pulsed Electron Beam Treatment

    Institute of Scientific and Technical Information of China (English)

    GAO Bo; HAO Sheng-zhi; ZOU Jian-xin; JIANG Li-min; ZHOU Ji-yang; DONG Chuang

    2004-01-01

    Surface modification of magnesium alloy AZ91HP (9wt%Al, 0.5wt%Zn, 0.5wt%Mn, Mg remaining percentage) by high current pulsed electron beam (HCPEB) treatment was studied in this paper. The secondary phase Mg17Al12 is nearly completely dissolved and as a result, a super-saturated solid solution forms on the re-melted surface.The microhardness is increased both in and far beyond the heat-affected zone (HAZ), reaching about 250μm.Measurements on sliding wear have shown that the wear resistance of the treated samples was improved by a factor of about 2.4 as compared to the as-received sample. It is also found that the sliding wear resistance can be further improved by surface alloying with TiN.

  9. A comparative study of principal component analysis and independent component analysis in eddy current pulsed thermography data processing

    Science.gov (United States)

    Bai, Libing; Gao, Bin; Tian, Shulin; Cheng, Yuhua; Chen, Yifan; Tian, Gui Yun; Woo, W. L.

    2013-10-01

    Eddy Current Pulsed Thermography (ECPT), an emerging Non-Destructive Testing and Evaluation technique, has been applied for a wide range of materials. The lateral heat diffusion leads to decreasing of temperature contrast between defect and defect-free area. To enhance the flaw contrast, different statistical methods, such as Principal Component Analysis and Independent Component Analysis, have been proposed for thermography image sequences processing in recent years. However, there is lack of direct and detailed independent comparisons in both algorithm implementations. The aim of this article is to compare the two methods and to determine the optimized technique for flaw contrast enhancement in ECPT data. Verification experiments are conducted on artificial and thermal fatigue nature crack detection.

  10. Surface Nanocrystallization of 3Cr13 Stainless Steel Induced by High-Current Pulsed Electron Beam Irradiation

    Directory of Open Access Journals (Sweden)

    Zhiyong Han

    2013-01-01

    Full Text Available The nanocrystalline surface was produced on 3Cr13 martensite stainless steel surface using high-current pulsed electron beam (HCPEB technique. The structures of the nanocrystallized surface were characterized by X-ray diffraction and electron microscopy. Two nanostructures consisting of fine austenite grains (50–150 nm and very fine carbides precipitates are formed in melted surface layer after multiple bombardments via dissolution of carbides and crater eruption. It is demonstrated that the dissolution of the carbides and the formation of the supersaturated Fe (C solid solution play a determining role on the microstructure evolution. Additionally, the formation of fine austenite structure is closely related to the thermal stresses induced by the HCPEB irradiation. The effects of both high carbon content and high value of stresses increase the stability of the austenite, which leads to the complete suppression of martensitic transformation.

  11. Feasibility study of current pulse induced 2-bit/4-state multilevel programming in phase-change memory

    Science.gov (United States)

    Liu, Yan; Fan, Xi; Chen, Houpeng; Wang, Yueqing; Liu, Bo; Song, Zhitang; Feng, Songlin

    2017-08-01

    In this brief, multilevel data storage for phase-change memory (PCM) has attracted more attention in the memory market to implement high capacity memory system and reduce cost-per-bit. In this work, we present a universal programing method of SET stair-case current pulse in PCM cells, which can exploit the optimum programing scheme to achieve 2-bit/ 4state resistance-level with equal logarithm interval. SET stair-case waveform can be optimized by TCAD real time simulation to realize multilevel data storage efficiently in an arbitrary phase change material. Experimental results from 1 k-bit PCM test-chip have validated the proposed multilevel programing scheme. This multilevel programming scheme has improved the information storage density, robustness of resistance-level, energy efficient and avoiding process complexity.

  12. Long Pulse EBW Start-up Experiments in MAST

    Directory of Open Access Journals (Sweden)

    Shevchenko V.F.

    2015-01-01

    Full Text Available Start-up technique reported here relies on a double mode conversion (MC for electron Bernstein wave (EBW excitation. It consists of MC of the ordinary (O mode, entering the plasma from the low field side of the tokamak, into the extraordinary (X mode at a mirror-polarizer located at the high field side. The X mode propagates back to the plasma, passes through electron cyclotron resonance (ECR and experiences a subsequent X to EBW MC near the upper hybrid resonance (UHR. Finally the excited EBW mode is totally absorbed at the Doppler shifted ECR. The absorption of EBW remains high even in cold rarefied plasmas. Furthermore, EBW can generate significant plasma current giving the prospect of a fully solenoid-free plasma start-up. First experiments using this scheme were carried out on MAST [1]. Plasma currents up to 33 kA have been achieved using 28 GHz 100kW 90ms RF pulses. Recently experimental results were extended to longer RF pulses showing further increase of plasma currents generated by RF power alone. A record current of 73kA has been achieved with 450ms RF pulse of similar power. The current drive enhancement was mainly achieved due to RF pulse extension and further optimisation of the start-up scenario.

  13. Mechanism of Fast Current Interruption in p -π -n Diodes for Nanosecond Opening Switches in High-Voltage-Pulse Applications

    Science.gov (United States)

    Sharabani, Y.; Rosenwaks, Y.; Eger, D.

    2015-07-01

    Step-recovery diodes operating in the snappy recovery regime are used as opening switches for generating narrow pulses with high-voltage amplitude. Physical modeling of the switching process is complex due to the large number of parameters involved, including diode structure, the extreme physical conditions, and the effect of external driving conditions. In this work, we address the problem by using a physical device simulator for solving the coupled device and electrical driving circuit equations. This method allows deciphering of the physical processes to take place in the diode during the fast current interruption phase. Herein we analyze the complete hard (snappy) reverse recovery process in short-base devices and determine the fast-transition-phase mechanism. It was found that the fast current interruption phase is constructed of two processes; the main parameters governing the switching time duration and the prepulse magnitude are the diode's reverse current density and its base-doping concentration. We describe the dependence of the switching performance in these parameters.

  14. Effect of pulse current on energy consumption and removal of heavy metals during electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian Ran

    Contamination of soils and groundwater keep attracting attention of worldwide. The contaminants of concern include a wide range of toxic pollutants such as heavy metals, radionuclides, and organic compounds. The environment and humans are exposed to these pollutants through different exposure...... pathways to unacceptable dosages, leading to intolerable adverse effects on both public health and the environment. In the last decades, soil and water remediation have gained growing awareness, as the necessity becomes clearer for development of such techniques for elimination of the negative impact from...... compartments. Therefore no current is wasted for carrying ions from one electrode compartment to the other. The EDR technique has been tested for decontamination of a variety of different heavy metal polluted particulate materials: mine tailings, soil, different types of fly ashes, sewage sludge, freshwater...

  15. Drowned coralline algal dominated deposits off Lanai, Hawaii; carbonate accretion and vertical tectonics over the last 30 ka

    Science.gov (United States)

    Webster, Jody M.; Clague, David A.; Braga, Juan Carlos; Spalding, Heather; Renema, Willem; Kelley, Christopher; Applegate, Bruce; Smith, John R.; Paull, Charles K.; Moore, James G.; Potts, Donald

    2006-01-01

    We present detailed bathymetry, remotely operated vehicle (ROV) and submersible observations, and sedimentary and radiocarbon age data from carbonate deposits recovered from two submerged terraces at − 150 m (T1) and − 230 m (T2) off Lanai, Hawaii. The tops of the terraces are veneered by relatively thin (coralline algal nodule, coralgal nodule, Halimeda and a derived oolitic facies deposited in intermediate (30–60 m) to deep fore-reef slope settings (60–120 m). The data are used to develop a sedimentary facies model that is consistent with eustatic sea-level variations over the last 30 ka. Both nodule facies on T1 and T2 initiated growth 30–29 ka following a fall in sea level of ∼50 m and increase in bottom currents during the transition from Marine Isotope Stage 3 to 2. The nodules accreted slowly throughout the Last Glacial Maximum when sea-level was relatively stable. Drowning occurred during the early deglaciation (17–16 ka) and was marked by the complete drowning of coralline algal nodules facies on T2 and incipient drowning of coralgal facies on T1. Abrupt sea-level rise during the middle deglaciation, perhaps associated with global meltwater pulse 1A (14–15 ka), finally drowned the coralgal facies on T1, which in turn was overlain by a deep-water Halimeda facies or an oolitic facies derived from upslope. Our data indicates that Lanai has experienced relatively little vertical tectonic movement over the last 30 ka. Using paleobathymetric data derived from the sedimentary facies, age vs. depth relationships, and published sea-level curves, we estimate that Lanai could be either slowly uplifting or subsiding, but at rates <0.1 m/kyr (uplift) or <0.4 m/kyr (subsidence) over this 30 kyr period.

  16. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  17. The R and D of half-sine pulser for eddy-current septum magnet

    CERN Document Server

    Fu Lu Xin; Kang Wen

    2002-01-01

    The SSRF requires high-amplitude half-sine pulse current (10kA) and relatively narrow pulse width (approx 60 mu s) for its eddy-current septum magnets. Moreover the machine will need a very high level of performance from the pulsers, particularly in terms of pulse amplitude stability and regulating range. For the convenience of maintenance the pulsers will be installed in the power supply hall and cabled to their eddy-current septum magnets by RG220/U. The author presents the pulser design and R and D results

  18. Pulsing frequency induced change in optical constants and dispersion energy parameters of WO{sub 3} films grown by pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Punitha, K. [Department of Physics, Alagappa University, Karaikudi 630 004 (India); Sivakumar, R., E-mail: krsivakumar1979@yahoo.com [Directorate of Distance Education, Alagappa University, Karaikudi 630 004 (India); Sanjeeviraja, C. [Department of Physics, Alagappa Chettiar College of Engineering and Technology, Karaikudi 630 004 (India)

    2014-03-21

    In this work, we present the pulsing frequency induced change in the structural, optical, vibrational, and luminescence properties of tungsten oxide (WO{sub 3}) thin films deposited on microscopic glass and fluorine doped tin oxide (SnO{sub 2}:F) coated glass substrates by pulsed dc magnetron sputtering technique. The WO{sub 3} films deposited on SnO{sub 2}:F substrate belongs to monoclinic phase. The pulsing frequency has a significant influence on the preferred orientation and crystallinity of WO{sub 3} film. The maximum optical transmittance of 85% was observed for the film and the slight shift in transmission threshold towards higher wavelength region with increasing pulsing frequency revealed the systematic reduction in optical energy band gap (3.78 to 3.13 eV) of the films. The refractive index (n) of films are found to decrease (1.832 to 1.333 at 550 nm) with increasing pulsing frequency and the average value of extinction coefficient (k) is in the order of 10{sup −3}. It was observed that the dispersion data obeyed the single oscillator of the Wemple-Didomenico model, from which the dispersion energy (E{sub d}) parameters, dielectric constants, plasma frequency, oscillator strength, and oscillator energy (E{sub o}) of WO{sub 3} films were calculated and reported for the first time due to variation in pulsing frequency during deposition by pulsed dc magnetron sputtering. The E{sub o} is change between 6.30 and 3.88 eV, while the E{sub d} varies from 25.81 to 7.88 eV, with pulsing frequency. The Raman peak observed at 1095 cm{sup −1} attributes the presence of W-O symmetric stretching vibration. The slight shift in photoluminescence band is attributed to the difference in excitons transition. We have made an attempt to discuss and correlate these results with the light of possible mechanisms underlying the phenomena.

  19. Electronic regulation of the SPS extraction quadrupole current pulse shape for improved stability of the extracted beam

    CERN Document Server

    Carlier, E; Vossenberg, Eugène B; CERN. Geneva. SPS and LEP Division

    1996-01-01

    In order to minimise the event pile-up and therefore optimise the detection efficiency, Chorus and Nomad experiments ask for a long and rectangular spill profile. At present the fast-slow extractio n is generated by driving the beam into a quadrupolar-octopolar resonance by exciting a quadrupole magnet with a semi-trapezoidal current [1]. The trapezoidal pulse shape is obtained by dischargin g a capacitor into the magnet coils. After a few milliseconds of undamped discharge a fixed resistor is switched into the circuit. The attenuation is then higher and the sine wave continues with a lower gradient. The two gradients can be adjusted by varying the initial capacitor voltage and the time at which the resistor is switched into the circuit. A further degree of freedom in determini ng the spill shape has been added by allowing the possibility of changing the second slope value independently of the initial conditions. This task is achieved by means of a variable current sour ce added in parallel to the fixed resis...

  20. Design and array signal suggestion of array type pulsed eddy current probe for health monitoring of metal tubes

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil [Dept. of Electrical Engineering, Kunsan National University, Kunsan (Korea, Republic of)

    2015-10-15

    An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.

  1. Comparison of premodulated interferential and pulsed current electrical stimulation in prevention of deep muscle atrophy in rats.

    Science.gov (United States)

    Tanaka, Minoru; Hirayama, Yusuke; Fujita, Naoto; Fujino, Hidemi

    2013-04-01

    The goal of this study was to compare the effects of electrical stimulation using pulsed current (PC) and premodulated interferential current (IC) on prevention of muscle atrophy in the deep muscle layer of the calf. Rats were randomly divided into 3 treatment groups: control, hindlimb unloading for 2 weeks (HU), and HU plus electrical stimulation for 2 weeks. The animals in the electrical stimulation group received therapeutic stimulation of the left (PC) or right (IC) calf muscles twice a day during the unloading period. Animals undergoing HU for 2 weeks exhibited significant loss of muscle mass, decreased cross-sectional area (CSA) of muscle fibers, and increased expression of ubiquitinated proteins in the gastrocnemius and soleus muscles compared with control animals. Stimulation with PC attenuated the effects on the muscle mass, fiber CSA, and ubiquitinated proteins in the gastrocnemius muscle. However, PC stimulation failed to prevent atrophy of the deep layer of the gastrocnemius muscle and the soleus muscle. In contrast, stimulation with IC inhibited atrophy of both the gastrocnemius and soleus muscles. In addition, the IC protocol inhibited the HU-induced increase in ubiquitinated protein expression in both gastrocnemius and soleus muscles. These results suggest that electrical stimulation with IC is more effective than PC in preventing muscle atrophy in the deep layer of limb muscles.

  2. Examination of pulsed eddy current for inspection of second layer aircraft wing lap-joint structures using outlier detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Butt, D.M., E-mail: Dennis.Butt@forces.gc.ca [Royal Military College of Canada, Dept. of Chemistry and Chemical Engineering, Kingston, Ontario (Canada); Underhill, P.R.; Krause, T.W., E-mail: Thomas.Krause@rmc.ca [Royal Military College of Canada, Dept. of Physics, Kingston, Ontario (Canada)

    2016-09-15

    Ageing aircraft are susceptible to fatigue cracks at bolt hole locations in multi-layer aluminum wing lap-joints due to cyclic loading conditions experienced during typical aircraft operation, Current inspection techniques require removal of fasteners to permit inspection of the second layer from within the bolt hole. Inspection from the top layer without fastener removal is desirable in order to minimize aircraft downtime while reducing the risk of collateral damage. The ability to detect second layer cracks without fastener removal has been demonstrated using a pulsed eddy current (PEC) technique. The technique utilizes a breakdown of the measured signal response into its principal components, each of which is multiplied by a representative factor known as a score. The reduced data set of scores, which represent the measured signal, are examined for outliers using cluster analysis methods in order to detect the presence of defects. However, the cluster analysis methodology is limited by the fact that a number of representative signals, obtained from fasteners where defects are not present, are required in order to perform classification of the data. Alternatively, blind outlier detection can be achieved without having to obtain representative defect-free signals, by using a modified smallest half-volume (MSHV) approach. Results obtained using this approach suggest that self-calibrating blind detection of cyclic fatigue cracks in second layer wing structures in the presence of ferrous fasteners is possible without prior knowledge of the sample under test and without the use of costly calibration standards. (author)

  3. A limited contribution of Ca2+ current facilitation to paired-pulse facilitation of transmitter release at the rat calyx of Held

    OpenAIRE

    Mueller, Martin; Felmy, Felix; Schneggenburger, Ralf

    2008-01-01

    Recent studies have suggested that transmitter release facilitation at synapses is largely mediated by presynaptic Ca2+ current facilitation, but the exact contribution of Ca2+ current facilitation has not been determined quantitatively. Here, we determine the contribution of Ca2+ current facilitation, and of an increase in the residual free Ca2+ concentration ([Ca2+](i)) in the nerve terminal, to paired-pulse facilitation of transmitter release at the calyx of Held. Under conditions of low r...

  4. Thyristor stack for pulsed inductive plasma generation.

    Science.gov (United States)

    Teske, C; Jacoby, J; Schweizer, W; Wiechula, J

    2009-03-01

    A thyristor stack for pulsed inductive plasma generation has been developed and tested. The stack design includes a free wheeling diode assembly for current reversal. Triggering of the device is achieved by a high side biased, self supplied gate driver unit using gating energy derived from a local snubber network. The structure guarantees a hard firing gate pulse for the required high dI/dt application. A single fiber optic command is needed to achieve a simultaneous turn on of the thyristors. The stack assembly is used for switching a series resonant circuit with a ringing frequency of 30 kHz. In the prototype pulsed power system described here an inductive discharge has been generated with a pulse duration of 120 micros and a pulse energy of 50 J. A maximum power transfer efficiency of 84% and a peak power of 480 kW inside the discharge were achieved. System tests were performed with a purely inductive load and an inductively generated plasma acting as a load through transformer action at a voltage level of 4.1 kV, a peak current of 5 kA, and a current switching rate of 1 kA/micros.

  5. Time-resolved soft X-ray core-level photoemission spectroscopy at 880 °C using the pulsed laser and synchrotron radiation and the pulse heating current

    Science.gov (United States)

    Abukawa, T.; Yamamoto, S.; Yukawa, R.; Kanzaki, S.; Mukojima, K.; Matsuda, I.

    2017-02-01

    We developed a time-resolved photoemission spectroscopy system for tracking the temporal variation in an electronic state of a heated sample. Our pump-probe method used laser and synchrotron radiation pulses on a silicon surface that was heated by a synchronized pulse current that did not interfere with the measurements. The transient surface photovoltage effect on the Si 2p core spectra was measured from room temperature to 880 °C and was found to be consistent with the thermal carrier distributions in silicon crystals at the corresponding temperatures. This versatile technique may have applications studying molecular dynamics on high temperature surfaces such as in catalytic reactions.

  6. Current Type of Electrical Discharge Machining Pulse Generator%电流型电火花加工脉冲电源的研究

    Institute of Scientific and Technical Information of China (English)

    宋博岩; 赵万生; 邵革良

    2001-01-01

    In this paper, the disadvantages of traditional independent type of electrical discharge machining pulse generator and inverter electrical discharge machining pulse generator are analyzed, and then the principle of current type of electrical discharge machining pulse generator is proposed for the first time. A large quantity of contrast tests between current type of electrical discharge machining pulse generator and traditional independent type of electrical discharge machining pulse generator show that the current type is not only high efficient energy-saving, but also meet the needs of machining performances.%分析了传统独立式电火花加工脉冲电源和逆变式电火花加工脉冲电源的不足,论述了电流型电火花加工脉冲电源的工作原理。大量的样机和独立式脉冲电源的对比工艺试验表明,电流型脉冲电源不仅满足了电火花加工多项性能指标的要求,而且达到了高效节能的效果。

  7. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10-2 Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  8. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments.

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10(-2) Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  9. INTERACTION OF RADIATION WITH MATTER. LASER PLASMA: Increase in the amplitude of hf currents during exposure of a neutral target to microsecond CO2 laser pulses

    Science.gov (United States)

    Antipov, A. A.; Losev, Leonid L.; Meshalkin, E. A.

    1988-09-01

    High-frequency electric currents were generated by irradiation of a metal target with CO2 laser pulses. It was found that the region where the ambient gas was photoionized had a decisive influence on the hf current amplitude. A method for increasing the amplitude of the current by creating an auxiliary laser jet on the target was proposed and used. An hf current of up to 1 A amplitude was observed at a frequency of 75 MHz and this current lasted for 1.5 μs.

  10. Improvement of wear resistance of AZ31 and AZ91HP by high current pulsed electron beam treatment

    Institute of Scientific and Technical Information of China (English)

    GAO Bo; HAO Sheng-zhi; DONG Chuang; TU Gan-feng

    2005-01-01

    The surface modification of magnesium alloys (AZ31 and AZ91HP) was studied by a high current pulsed electron beam(HCPEB). The results show that the cross-sectional microhardness of treated samples increases not only in the heat affected zone(HAZ), but also beyond HAZ, reaching over 250 μm. This is due to the action of quasi-static thermal stress and the shock thermal stress wave with materials, which result in its fast deformation on the surface layer and so increases microhardness. For the AZ91HP alloy, a nearly complete dissolution of the intermetallic phase Mg17Al12 is observed, and a super-saturated solid solution forms on the re-melted surface, which is due to the solute trapping effect during the fast solidification process. Measurements on sliding wear show that wear resistance is improved by approximately 5.6 and 2.4 times for the AZ31 and AZ91HP respectively, as compared with as-received samples.

  11. High Temperature Corrosion studies on Pulsed Current Gas Tungsten Arc Welded Alloy C-276 in Molten Salt Environment

    Science.gov (United States)

    Manikandan, M.; Arivarasu, M.; Arivazhagan, N.; Puneeth, T.; Sivakumar, N.; Murugan, B. Arul; Sathishkumar, M.; Sivalingam, S.

    2016-09-01

    Alloy C-276 is widely used in the power plant environment due to high strength and corrosion in highly aggressive environment. The investigation on high- temperature corrosion resistance of the alloy C-276 PCGTA weldment is necessary for prolonged service lifetime of the components used in corrosive environments. Investigation has been carried out on Pulsed Current Gas Tungsten Arc Welding by autogenous and different filler wires (ERNiCrMo-3 and ERNiCrMo-4) under molten state of K2SO4-60% NaCl environment at 675oC under cyclic condition. Thermogravimetric technique was used to establish the kinetics of corrosion. Weight gained in the molten salt reveals a steady-state parabolic rate law while the kinetics with salt deposits displays multi-stage growth rates. PCGTA ERNiCrMo-3 shows the higher parabolic constant compared to others. The scale formed on the weldment samples upon hot corrosion was characterized by using X-ray diffraction, SEM and EDAX analysis to understand the degradation mechanisms. From the results of the experiment the major phases are identified as Cr2O3, Fe2O3, and NiCr2O4. The result showed that weld fabricated by ERNiCrMo-3 found to be more prone to degradation than base metal and ERNiCrMo-4 filler wire due to higher segregation of alloying element of Mo and W in the weldment

  12. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R. [Department of Physics, Royal Military College of Canada, Kingston, ON (Canada)

    2014-02-18

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

  13. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    Science.gov (United States)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R.

    2014-02-01

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

  14. Lake-expanding events in the Tibetan Plateau since 40 kaBP

    Institute of Scientific and Technical Information of China (English)

    贾玉连; 施雅风; 王苏民; 蒋雪中; 李世杰; 王爱军; 李徐生

    2001-01-01

    Since 40 kaBP, the current endorheism on the Tibetan Plateau had experienced at least four lake-expanding events, at 40-28 kaBP, 19-15 kaBP, 13-11 kaBP, 9.0-5.0 kaBP, respectively. The 40-28 kaBP and 9.0-5.0 kaBP lake-expanding events, corresponding to the global warming periods, were mainly determined by the abundant summer monsoon rainfall brought by strong Indian monsoon, aroused by enhanced solar radiation at earth orbital precessional cycle. The 40-28 kaBP lake-expanding event, also called the great lake period or the pan-lake period, for several great lake groups had come into being by the interconnection of the presently isolated and closed lake catchments. The total lake area over the Tibetan Plateau was estimated at least up to 150000 km2, 3.8 times of the present, and the lake supply coefficients were about 3-10. The 9.0-5.0 kaBP lake-expanding, with a total lake area of 68000 km2, less than the above mentioned reflected the Indian monsoon rainfall less than that of 40-28 kaBP. The expanded lak

  15. Elimination of DC-Link Current Ripple for Modular Multilevel Converters With Capacitor Voltage-Balancing Pulse-Shifted Carrier PWM

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2015-01-01

    The modular multilevel converter (MMC) is attractive for medium- and high-power applications because of its high modularity, availability, and power quality. In this paper, the current ripple on the dc link of the three-phase MMC derived from the phase-shifted carrier-based pulse-width modulation...

  16. Structural, Optical, and Dielectric Investigations of the Relaxor PLZT 9,75/65/35 Ceramics Irradiated by High-Current Pulsed Electron Beam

    CERN Document Server

    Efimov, V V; Kalmikov, A V; Klevtsova, E A; Minashkin, V F; Novikova, N N; Sikolenko, V V; Skripnik, A V; Sternberg, A; Tiutiunnikov, S I; Yakovlev, V A

    2002-01-01

    First time comprehensive study of high-current pulsed electron irradiation effects on the structural, optical and dielectric properties of relaxor (Pb_{(1-x)}La^{x}(Zr_{0.65}Ti_{0.35})_{1-x/4}O_{3} ceramics with x=9.75% has been provided. The electron beam had the following parameters: energy E_{e}=250 keV, current density J_{e}=1000 A/cm^{2}, pulse duration tau = 300 ns, density 10^{15} electrons/cm^{2} per pulse. Infrared reflectivity spectra in the region of 100-2000 cm^{-1} were obtained in virgin, irradiated by 1500 pulses and annealed up to t=500^{circ}C ceramics. The reconstruction of perovskite ABO_{3} structure in irradiated samples has been studied by complex use of X-ray and neutron scattering and IR spectroscopy techniques revealing the changes in transverse and longitudinal phonon modes, oscillators strength and damping of modes. Radiation effects on temperature behaviour of dielectric permittivity in the region of phase transition were studied. The possible mechanisms of pulsed electron irradiat...

  17. High power Ka band TWT amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Golkowski, C.; Ivers, J.D.; Nation, J.A.; Wang, P.; Schachter, L.

    1999-07-01

    Two high power 35 GHz TWT amplifiers driven by a relativistic pencil, 850 kV, 200A electron beam have been assembled and tested. The first had a dielectric slow wave structure and was primarily used to develop diagnostics, and to gain experience in working with high power systems in Ka band. The source of the input power for the amplifier was a magnetron producing a 30 kW, 200ns long pulse of which 10 kW as delivered to the experiment. The 30 cm long dielectric (Teflon) amplifier produced output power levels of about 1 MW with a gain of about 23 dB. These results are consistent with expectations from PIC code simulations for this arrangement. The second amplifier, which is a single stage disk loaded slow wave structure, has been designed. It consists of one hundred uniform cells with two sets of ten tapered calls at the ends to lower the reflection coefficient. The phase advance per cell is {pi}/2. The amplifier passband extends from 28 to 40 GHz. It is designed to increase the output power to about 20 MW. The amplifier is in construction and will be tested in the near future. Details of the design of both systems will be provided and initial results from the new amplifier presented.

  18. Ka-band MMIC microstrip array for high rate communications

    Science.gov (United States)

    Lee, R. Q.; Raquet, C. A.; Tolleson, J. B.; Sanzgiri, S. M.

    1991-01-01

    In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

  19. Plasma Formation and Evolution on Cu, Al, Ti, and Ni Surfaces Driven by a Mega-Ampere Current Pulse

    Science.gov (United States)

    Yates, Kevin C.

    Metal alloy mm-diameter rods have been driven by a 1-MA, 100-ns current pulse from the Zebra z-pinch. The intense current produces megagauss surface magnetic fields that diffuse into the load, ohmically heating the metal until plasma forms. Because the radius is much thicker than the skin depth, the magnetic field reaches a much higher value than around a thin-wire load. With the "barbell" load design, plasma formation in the region of interest due to contact arcing or electron avalanche is avoided, allowing for the study of ohmically heated loads. Work presented here will show first evidence of a magnetic field threshold for plasma formation in copper 101, copper 145, titanium, and nickel, and compare with previous work done with aluminum. Copper alloys 101 and 145, titanium grade II, and nickel alloy 200 form plasma when the surface magnetic field reaches 3.5, 3.0, 2.2, and 2.6 megagauss, respectively. Varying the element metal, as well as the alloy, changes multiple physical properties of the load and affects the evolution of the surface material through the multiple phase changes. Similarities and differences between these metals will be presented, giving motivation for continued work with different material loads. During the current rise, the metal is heated to temperatures that cause multiple phase changes. When the surface magnetic field reaches a threshold, the metal ionizes and the plasma becomes pinched against the underlying cooler, dense material. Diagnostics fielded have included visible light radiometry, two-frame shadowgraphy (266 and 532 nm wavelengths), time-gated EUV spectroscopy, single-frame/2ns gated imaging, and multi-frame/4ns gated imaging with an intensified CCD camera (ICCD). Surface temperature, expansion speeds, instability growth, time of plasma formation, and plasma uniformity are determined from the data. The time-period of potential plasma formation is scrutinized to understand if and when plasma forms on the surface of a heated

  20. Design and verification of a 24 kA calibration head for a DCCT test facility

    CERN Document Server

    Fernqvist, G; Saab, A

    1999-01-01

    The Large Hadron Collider (LHC) is CERN's next particle accelerator project, scheduled for commissioning in 2005. The project requires accurate current measurements above 10 kA. Calibration heads have been developed in collaboration with industry to work up to 24 kA at sub-ppm accuracy. The paper describes the design and verification.

  1. 脉冲涡流阵列成像检测%Study of Pulsed Eddy Current Array Imaging Detection

    Institute of Scientific and Technical Information of China (English)

    赖圣; 付跃文

    2011-01-01

    It is difficult to detect flaw buried in the multi-layer riveted structure of aircraft. This paper designed a pulsed eddy current testing system, including the linear array probes and imaging system. The riveted aluminum alloy sample fabricated with both inner crack and corrosion was tested by the proposed system, and an imaging scan was achieved by the way of time slice applied in getting eigenvalue matrix from characteristic signal. The results of experimentation showed that the use of time slice analysis method can be efficiently used to detect subsurface and inner defects in multi layer structure.%飞机多层铆接结构中内层埋藏缺陷的检测是无损检测领域的一个难点。设计了一套脉冲涡流阵列检测系统,包括线性霍尔阵列探头和软件成像系统。应用该系统对铝合金深层裂缝及铆接结构内层裂纹腐蚀缺陷进行检测,通过时间切片分析法获取缺陷信号特征值,组成特征幅值的矩阵,实现成像扫描。试验结果表明,采用时间切片分析法能够有效地对试件近表面及内层的缺陷进行成像检测。

  2. Long-pulse production of high current negative ion beam by using actively temperature controlled plasma grid for JT-60SA negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, A.; Hanada, M.; Yoshida, M.; Umeda, N.; Hiratsuka, J.; Kashiwagi, M.; Tobari, H.; Watanabe, K. [Japan Atomic Energy Agency, 801-1, Mukoyama, Naka 311-0193 (Japan); Grisham, L. R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States)

    2015-04-08

    The temperature control system of the large-size plasma grid has been developed to realize the long pulse production of high-current negative ions for JT-60SA. By using this prototype system for the JT-60SA ion source, 15 A negative ions has been sustained for 100 s for the first time, which is three times longer than that obtained in JT-60U. In this system, a high-temperature fluorinated fluid with a high boiling point of 270 degree Celsius is circulated in the cooling channels of the plasma grids (PG) where a cesium (Cs) coverage is formed to enhance the negative ion production. Because the PG temperature control had been applied to only 10% of the extraction area previously, the prototype PG with the full extraction area (110 cm × 45 cm) was developed to increase the negative ion current in this time. In the preliminary results of long pulse productions of high-current negative ions at a Cs conditioning phase, the negative ion production was gradually degraded in the last half of 100 s pulse where the temperature of an arc chamber wall was not saturated. From the spectroscopic measurements, it was found that the Cs flux released from the wall might affect to the negative ion production, which implied the wall temperature should be kept low to control the Cs flux to the PG for the long-pulse high-current production. The obtained results of long-pulse production and the PG temperature control method contributes the design of the ITER ion source.

  3. KaVA ESTEMA project

    Science.gov (United States)

    Oyadomari, Miyako; Imai, Hiroshi; Cho, Se-Hyung; Asaki, Yoshiharu; Choi, Yoon-Kyong; Kim, Jaeheon; Yun, Youngjoo; Matsumoto, Naoko; Min, Cheul-Hong; Oyama, Tomoaki; Yoon, Sung-Chul; Yoon, Dong-Hwan; Kim, Dong-Jin; Dodson, Richard; Rioja, Maria; Burns, Ross; Orosz, Gabor; Nakagawa, Akiharu; Chibueze O, James; Nakashima, Jun-ichi; Sobolev, Andrey

    2016-07-01

    The ESTEMA (Expanded Study on Stellar Masers) project is one of three Large Programs of the KaVA (the combined array of the Korean VLBI Network and Japanese VLBI Exploration of Radio Astrometry), and conducted in 2015-2016. It aims to publish a database of the largest sample of VLBI images of circumstellar water (H2O) and silicon-monoxide (SiO) maser sources towards circumstellar envelopes (CSEs) of 80 evolved stars in late AGB to early post-AGB phase. Here we present the specifications of the ESTEMA observations and the planned scientific goals in order to share the basic information of the ESTEMA with astronomical community and encourage future collaborations with the ESTEMA and future follow-up observations for the targeted stars.

  4. DARHT 2 kA Cathode Development

    Energy Technology Data Exchange (ETDEWEB)

    Henestroza, E.; Houck, T.; Kwan, J.W.; Leitner, M.; Miram, G.; Prichard, B.; Roy, P.K.; Waldron, W.; Westenskow, G.; Yu, S.; Bieniosek, F.M.

    2009-03-09

    In the campaign to achieve 2 kA of electron beam current, we have made several changes to the DARHT-II injector during 2006-2007. These changes resulted in a significant increase in the beam current, achieving the 2 kA milestone. Until recently (before 2007), the maximum beam current that was produced from the 6.5-inch diameter (612M) cathode was about 1300 A when the cathode was operating at a maximum temperature of 1140 C. At this temperature level, the heat loss was dominated by radiation which is proportional to temperature to the fourth power. The maximum operating temperature was limited by the damage threshold of the potted filament and the capacity of the filament heater power supply, as well as the shortening of the cathode life time. There were also signs of overheating at other components in the cathode assembly. Thus it was clear that our approach to increase beam current could not be simply trying to run at a higher temperature and the preferred way was to operate with a cathode that has a lower work function. The dispenser cathode initially used was the type 612M made by SpectraMat. According to the manufacturer's bulletin, this cathode should be able to produce more than 10 A/cm{sup 2} of current density (corresponding to 2 kA of total beam current) at our operating conditions. Instead the measured emission (space charge limited) was 6 A/cm{sup 2}. The result was similar even after we had revised the activation and handling procedures to adhere more closely to the recommend steps (taking longer time and nonstop to do the out-gassing). Vacuum was a major concern in considering the cathode's performance. Although the vacuum gauges at the injector vessel indicated 10{sup -8} Torr, the actual vacuum condition near the cathode in the central region of the vessel, where there might be significant out-gassing from the heater region, was never determined. Poor vacuum at the surface of the cathode degraded the emission (by raising the work function

  5. Generation of femtosecond spin current pulses via non-thermal spin-dependent Seebeck effect and their interaction with ferromagnets in spin valves

    CERN Document Server

    Alekhin, Alexandr; Ilin, Nikita; Meyburg, Jan P; Diesing, Detlef; Roddatis, Vladimir; Rungger, Ivan; Stamenova, Maria; Sanvito, Stefano; Bovensiepen, Uwe; Melnikov, Alexey

    2016-01-01

    Using the sensitivity of magneto-induced second harmonic generation to spin currents (SC), we demonstrate in Fe/Au/Fe/MgO(001) pseudo spin valves the generation of 250 fs-long SC pulses. Their temporal profile indicates that superdiffusive hot electron transport across a sub-100~nm Au layer is close to the ballistic limit and the pulse duration is primarily determined by the thermalization time of laser-excited hot carriers in Fe. Considering the calculated spin-dependent Fe/Au interface transmittance we conclude that the non-thermal spin-dependent Seebeck effect is responsible for the generation of ultrashort SC pulses. We also show that hot electron spins rotate upon interaction with non-collinear magnetization at the Au/Fe interface, which holds high potential for future spintronic devices.

  6. Enhanced performance of a repetitively pulsed 130 mJ KrF laser with improved pre-ionization parameters

    Indian Academy of Sciences (India)

    N S Benerji; A Singh; N Varshnay; Bijendra Singh

    2014-01-01

    Studies related to the effect of pre-ionizer on laser output energy of a repetitively pulsed KrF laser are presented. The dependence of laser output energy, spectral width and beam spot homogeneity on pre-ionization parameters, namely its current and voltage rise time are reported here. Here, effectiveness of pre-ionization is optimized by improving pre-ionization current and rise time of the pump pulse of the automatic UV pre-ionizer KrF laser. It is observed that by increasing pre-ionization current from 6 kA to 10.6 kA, the output energy increases by about 30% (from 100 to 130 mJ). It is also observed that the emission spectral width reduces by almost 60% by increasing the pre-ionization current. Regular homogeneous and well-developed beam spot (nearly Hat-Top profile) was achieved under these optimized conditions.

  7. Fabrication of FeAl-WC composite and metal/metal joint using pulse current sintering technique; Pulse tsudenshoketsu gijutsu wo riyoshita FEAl-WC fukugozai narabini kinzoku setsugotaino sakusei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, A.; Kobayashi, K.; Nishio, T.; Ozaki, K.; Sugiyama, A.; Kamiya, A.; Asahina, T. [National Industrial Research Institute of Nagoya,Nagoya (Japan)

    2000-10-25

    Fe-40at%Al+0 {approx} 5at%B powder mixtures were milled in a planetary ball mill under argon atmosphere. The size of the particles decreased with increasing the B content. The mechanical properties such as transverse rupture strength and vickers hardness for Fe-40at%Al+3at%B compacts prepared by pulse current sintering were improved relative to Fe-40at%Al compacts. FeAl{sub 3}-0 {approx} 65vol%WC composites were prepared by using pulse current sintering in vacuum at the sintering temperature of 1,373 - 1,473K. The B added FeAl composites with 50vol% WC exhibited a transverse rupture strength of 1.7GPa and vickers hardness of 1,240. These values were 1.2 {approx} 1.5 times higher than those of FeAl-50vol%WC composites. A novel process for diffusion joining, a combination of pulse current sintering with pseudo-hot isostatic pressing (PHIP-PCS), was proposed. The joining between iron and aluminium tablets using PHIP-PCS process was successfully performed. (author)

  8. Cold-cathode, pulsed-power plasma discharge switch

    Science.gov (United States)

    Goebel, Dan M.

    1996-09-01

    CROSSATRONTMmodulator switches are cold-cathode, grid-controlled, plasma-discharge devices that are used for thyratron and hard-tube replacement in high-voltage, pulsed-power applications. CROSSATRON modulator switches have been used to produce square pulses of up to 100 kV and 1000 A, and CROSSATRON laser-discharge switches have switched peak discharge currents of up to 10 kA at 40 kV. The major advantage that CROSSATRON switches offer over other plasma switches is a rapid deionization time that permits high pulse-repetition frequencies (103 to 106 pulses per second depending on the application), and a long life associated with the cold-cathode plasma production mechanism. Compared to hard tubes, CROSSATRON switches have a relatively low forward voltage drop (500 V), the ability to close and open up to 1 kA of peak current, and lower grid-drive power requirements. In this article, we describe the physical mechanisms for how the switch works based on simple models and experimental data. The design of CROSSATRON switches is explained, and characteristic performance in closing and opening applications is described and explained.

  9. Fade Mitigation Techniques at Ka-Band

    Science.gov (United States)

    Dissanayake, Asoka (Editor)

    1996-01-01

    Rain fading is the dominant propagation impairment affecting Ka-band satellite links and rain fade mitigation is a key element in the design of Ka-band satellite networks. Some of the common fade mitigation techniques include: power control, diversity, adaptive coding, and resource sharing. The Advanced Communications Technology Satellite (ACTS) provides an excellent opportunity to develop and test Ka-band rain impairment amelioration techniques. Up-link power control and diversity are discussed in this paper.

  10. A limited contribution of Ca2+ current facilitation to paired-pulse facilitation of transmitter release at the rat calyx of Held.

    Science.gov (United States)

    Müller, Martin; Felmy, Felix; Schneggenburger, Ralf

    2008-11-15

    Recent studies have suggested that transmitter release facilitation at synapses is largely mediated by presynaptic Ca(2+) current facilitation, but the exact contribution of Ca(2+) current facilitation has not been determined quantitatively. Here, we determine the contribution of Ca(2+) current facilitation, and of an increase in the residual free Ca(2+) concentration ([Ca(2+)](i)) in the nerve terminal, to paired-pulse facilitation of transmitter release at the calyx of Held. Under conditions of low release probability imposed by brief presynaptic voltage-clamp steps, transmitter release facilitation at short interstimulus intervals (4 ms) was 227 +/- 31% of control, Ca(2+) current facilitation was 113 +/- 4% of control, and the peak residual [Ca(2+)](i) was 252 +/- 18 nm over baseline. By inferring the 'local' [Ca(2+)](i) transients that drive transmitter release during these voltage-clamp stimuli with the help of a kinetic release model, we estimate that Ca(2+) current facilitation contributes to approximately 40% to paired-pulse facilitation of transmitter release. The remaining component of facilitation strongly depends on the build-up, and on the decay of the residual free [Ca(2+)](i), but cannot be explained by linear summation of the residual free [Ca(2+)](i), and the back-calculated 'local' [Ca(2+)](i) signal, which only accounts for approximately 10% of the total release facilitation. Further voltage-clamp experiments designed to compensate for Ca(2+) current facilitation demonstrated that about half of the observed transmitter release facilitation remains in the absence of Ca(2+) current facilitation. Our results indicate that paired-pulse facilitation of transmitter release at the calyx of Held is driven by at least two distinct mechanisms: Ca(2+) current facilitation, and a mechanism independent of Ca(2+) current facilitation that closely tracks the time course of residual free [Ca(2+)](i).

  11. A pulse of mid-Pleistocene rift volcanism in Ethiopia at the dawn of modern humans

    Science.gov (United States)

    Hutchison, William; Fusillo, Raffaella; Pyle, David M.; Mather, Tamsin A.; Blundy, Jon D.; Biggs, Juliet; Yirgu, Gezahegn; Cohen, Benjamin E.; Brooker, Richard A.; Barfod, Dan N.; Calvert, Andrew T.

    2016-10-01

    The Ethiopian Rift Valley hosts the longest record of human co-existence with volcanoes on Earth, however, current understanding of the magnitude and timing of large explosive eruptions in this region is poor. Detailed records of volcanism are essential for interpreting the palaeoenvironments occupied by our hominin ancestors; and also for evaluating the volcanic hazards posed to the 10 million people currently living within this active rift zone. Here we use new geochronological evidence to suggest that a 200 km-long segment of rift experienced a major pulse of explosive volcanic activity between 320 and 170 ka. During this period, at least four distinct volcanic centres underwent large-volume (>10 km3) caldera-forming eruptions, and eruptive fluxes were elevated five times above the average eruption rate for the past 700 ka. We propose that such pulses of episodic silicic volcanism would have drastically remodelled landscapes and ecosystems occupied by early hominin populations.

  12. Ka Band Parabolic Deployable Antenna (KaPDA) for Interplanetary CubeSat Communications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Ka Band Parabolic Deployable Antenna (KaPDA) for Interplanetary CubeSat Communications allowing moving up from UHF, S or X to get higher gain for a given diameter.

  13. Design of Pulsed Eddy Current Exciting Source Based on Virtual Instrument%基于虚拟仪器的脉冲涡流激励源设计

    Institute of Scientific and Technical Information of China (English)

    邱选兵; 魏计林; 崔小朝; 黄祥康; 刘路路

    2013-01-01

    Pulsed eddy current testing is a new research field of eddy current testing technology. A square waveform with adjusting duty is employed as exciting source. Combined with virtual instrument technology, the pulsed eddy current exciting source of direct digital synthesizer is designed based on USB interface. The experimental results indicate that the exciting source has the performance of the continuous adjustable frequency (0. 5 — 500 kHz) and duty (10% — 90%), high resolution (0. 011 6 Hz) , stability, friendly interface and so on. It is very suitable for the driving requirements of the pulsed eddy current probe, and has some application prospect.%脉冲涡流检测是电涡流检测技术的一个最新研究,激励源采用一定占空比的方波信号.结合虚拟仪器技术,设计了一种USB接口的直接数字合成的脉冲涡流激励源.实验结果表明该激励源有占空比(10%~90%),频率(0.5 k~500 kHz)连续可调,分辨率高(0.011 6 Hz),稳定可靠,界面友好等优点,能够满足脉冲涡流探头驱动要求,具有一定应用前景.

  14. A photocatalytic approach in micro arc oxidation of WO{sub 3}-TiO{sub 2} nano porous semiconductors under pulse current

    Energy Technology Data Exchange (ETDEWEB)

    Bayati, M.R., E-mail: mbayati@ncsu.edu [Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC 27695-7907 (United States); School of Metallurgy and Materials Engineering, Iran University of Science and Technology, P.O. Box 16845-161, Tehran (Iran, Islamic Republic of); Golestani-Fard, F. [School of Metallurgy and Materials Engineering, Iran University of Science and Technology, P.O. Box 16845-161, Tehran (Iran, Islamic Republic of); Center of Excellence for Advanced Materials, Iran University of Science and Technology, P.O. Box 16845-195, Tehran (Iran, Islamic Republic of); Moshfegh, A.Z. [Department of Physics, Sharif University of Technology, P.O. Box 11155-9161, Tehran (Iran, Islamic Republic of); Institute for Nanoscience and Nanotechnology, Sharif University of Technology, P.O. Box 14588-89694, Tehran (Iran, Islamic Republic of); Molaei, R. [School of Metallurgy and Materials Engineering, Iran University of Science and Technology, P.O. Box 16845-161, Tehran (Iran, Islamic Republic of)

    2011-08-15

    Graphical abstract: WO3-TiO2 layers were fabricated via microarc oxidation process and effect of the electrical current type on their photocatalytic performance under UV and visible illuminations was investigated. Highlights: {yields} WO3-TiO2 layers were grown by MAO under pulse current for the first time. {yields} Effect of the frequency and duty cycle on properties of the layers was studied. {yields} A correlation between catalytic performance and growth conditions was proposed. - Abstract: Since ultraviolet (UV) irradiation cannot be applied for a long time in practical applications, it is necessary to develop a narrow band gap photocatalyst to decompose environmental pollutants under visible irradiation. In this research, (WO{sub 3}){sub x}-(TiO{sub 2}){sub 1-x} nano-porous layers were fabricated by micro arc oxidation (MAO) and influence of the electrical current type on their physical and chemical properties was investigated. Morphological studies, performed by SEM technique, revealed that pore size and roughness decreased with the frequency and increased with the duty cycle. The pulse-grown layers had a finer structure when compared to those fabricated under direct current. XRD and XPS results showed that the layers consisted of anatase, rutile, and tungsten oxide phases. Applying pulse current resulted in higher anatase relative contents. Band gap energies of the MAO-grown TiO{sub 2} and WO{sub 3}-TiO{sub 2} layers were respectively measured as 3.14 and 2.96 eV. The layers fabricated under pulse current exhibited higher photoactivity under ultraviolet and visible illuminations as compared to the layers grown under direct current. Methylene blue (MB) was used as a model material to examine photocatalytic performance of the layers. Maximum MB-photodegradation reaction rate constants over the pulse-synthesized WO{sub 3}-TiO{sub 2} layers were measured as 0.0269 and 0.0129 min{sup -1} for ultraviolet and visible irradiations. For layers grown under direct

  15. 脉冲漏磁检测中的涡流效应%Eddy Current Effect in Pulsed Magnetic Flux Leakage Testing

    Institute of Scientific and Technical Information of China (English)

    费骏骉; 左宪章; 田贵云; 张云; 张韬

    2012-01-01

    In order to comprehend the characteristic of eddy current effect in pulsed magnetic flux leakage testing, this paper lays the foundation to further analyze pulsed magnetic flux leakage testing signal, builds simulating model of finite element in pulsed magnetic flux leakage testing, observes the distribution of transient magnetic field and induced eddy current in the test and analyzes and studies the features of characteristic quantity of induced eddy current and influential factors. The result shows that transient magnetic field and induced eddy current overall correspond with skin effect and affect each other in pulsed magnetic flux leakage testing. Induced eddy current has the feature of shallow penetrating depth and strong induction. Peak time of eddy current density has relative stronger resolution on depth direction. Electrical conductivity and magnetic conductivity affect the penetrating depth of induced eddy current and resolution of peak time of density on depth direction; pulsed stimulating ascendant time constant only affects the penetrating depth of induced eddy current, not relevant to resolution of peak time of density on depth direction.%为了解脉冲漏磁检测中涡流效应的特点,奠定进一步分析脉冲漏磁检测信号的基础,建立了脉冲漏磁检测的有限元仿真模型,观察了检测中瞬态磁场和感生涡流的分布,分析了感生涡流特征量的特点及影响因素。结果表明,脉冲漏磁检测中,瞬态磁场和感生涡流总体上符合集肤效应并相互影响,其中感生涡流具有渗透深度浅、感应强度大的特点,涡流密度峰值时间在深度方向上有较强的分辨率。电导率和磁导率影响感生涡流的渗透深度和密度峰值时间在深度方向上的分辨率;脉冲激励上升时间常数只影响感生涡流的渗透深度,而和密度峰值时间在深度方向上的分辨率无关。

  16. Test results on prototype 50-kA conductors for tokamak induction heating coils

    Energy Technology Data Exchange (ETDEWEB)

    Wollan, J.J.; Williamson, K.D. Jr.; Turck, B.

    1979-01-01

    Fabricability of a very large, 50-kA superconducting cable has been demonstrated. Test results of critical current and stability measurements are presented. The design critical current of 55 kA at 7 T was met. The recovery current was degraded as a result of the expectedly poor insulation system. Energy loss measurements on prototype advanced mixed matrix conductors, which will be incorporated into a second prototype cable, are presented.

  17. The eddy current induced in the pulsed bump magnet for the CSNS/RCS injection%The eddy current induced in the pulsed bump magnet for the CSNS/RCS injection

    Institute of Scientific and Technical Information of China (English)

    宋金星; 康文; 霍丽华; 郝耀斗; 王磊

    2011-01-01

    The injecton pulsed bending bump magnets of Rapid Cycling Synchrotron (RCS) in China Spalla- tion Neutron Source (CSNS) consist of four horizontal bending (BH) magnets and four vertical bending (BV) magnets. The BH magnets are operated at a repetition rat

  18. A 7 T Pulsed Magnetic Field Generator for Magnetized Laser Plasma Experiments

    Science.gov (United States)

    Hu, Guangyue; Liang, Yihan; Song, Falun; Yuan, Peng; Wang, Yulin; Zhao, Bin; Zheng, Jian

    2015-02-01

    A pulsed magnetic field generator was developed to study the effect of a magnetic field on the evolution of a laser-generated plasma. A 40 kV pulsed power system delivered a fast (~230 ns), 55 kA current pulse into a single-turn coil surrounding the laser target, using a capacitor bank of 200 nF, a laser-triggered switch and a low-impedance strip transmission line. A one-dimensional uniform 7 T pulsed magnetic field was created using a Helmholtz coil pair with a 6 mm diameter. The pulsed magnetic field was controlled to take effect synchronously with a nanosecond heating laser beam, a femtosecond probing laser beam and an optical Intensified Charge Coupled Device (ICCD) detector. The preliminary experiments demonstrate bifurcation and focusing of plasma expansion in a transverse magnetic field.

  19. Effect of pulsed current micro plasma arc welding process parameters on fusion zone grain size and ultimate tensile strength of Inconel 625 sheets

    Institute of Scientific and Technical Information of China (English)

    Kondapalli Siva Prasad; Chalamalasetti Srinivasa Rao; Damera Nageswara Rao

    2012-01-01

    The paper focuses on developing mathematical models to predict grain size and ultimate tensile strength of pulsed current micro plasma arc welded Inconel 625 nickel alloy.Four factors,five levels,central composite rotatable design matrix is used to optimize the number of experiments.The mathematical models have been developed by response surface method.The adequacy of the models is checked by analysis of variance technique.By using the developed mathematical models,grain size and ultimate tensile strength of the joints can be predicted with 99%0 confidence level.Contour plots are drawn to study the interaction effect of pulsed current micro plasma arc welding parameters on fusion zone grain size and ultimate tensile strength of Inconel 625 weld ioints.

  20. Ka-band MMIC subarray technology program (Ka-Mist)

    Science.gov (United States)

    Pottinger, W.

    1995-09-01

    Ka-band monolithic microwave integrated circuit (MMIC) arrays have been considered as having high potential for increasing the capability of space, aircraft, and land mobile communication systems in terms of scan performance, data rate, link margin, and flexibility while offering a significant reduction in size, weight, and power consumption. Insertion of MMIC technology into antenna systems, particularly at millimeter wave frequencies using low power and low noise amplifiers in closed proximity to the radiating elements, offers a significant improvement in the array transmit efficiency, receive system noise figure, and overall array reliability. Application of active array technology also leads to the use of advanced beamforming techniques that can improve beam agility, diversity, and adaptivity to complex signal environments. The objective of this program was to demonstrate the technical feasibility of the 'tile' array packaging architecture at EHF via the insertion of 1990 MMIC technology into a functional tile array or subarray module. The means test of this objective was to demonstrate and deliver to NASA a minimum of two 4 x 4 (16 radiating element) subarray modules operating in a transmit mode at 29.6 GHz. Available (1990) MMIC technology was chosen to focus the program effort on the novel interconnect schemes and packaging requirements rather than focusing on MMIC development. Major technical achievements of this program include the successful integration of two 4 x 4 subarray modules into a single antenna array. This 32 element array demonstrates a transmit EIRP of over 300 watts yielding an effective directive power gain in excess of 55 dB at 29.63 GHz. The array has been actively used as the transmit link in airborne/terrestrial mobile communication experiments accomplished via the ACTS satellite launched in August 1993.

  1. Electrodeposition of Gold to Conformally Fill High Aspect Ratio Nanometric Silicon Grating Trenches: A Comparison of Pulsed and Direct Current Protocols

    OpenAIRE

    Znati, Sami A.; Chedid, Nicholas; Miao, Houxun; Chen,Lei; Bennett, Eric E.; Wen, Han

    2015-01-01

    Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of x-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in sub-micron-width silicon trenches with an aspect ratio greater than 35 over a grating area of several square centimeters is challenging and has not been described in the literature previously. A comparison of pulsed plating and constant current plating led to a gold electroplatin...

  2. Research progress of directional pulsed eddy current strain testing%方向性脉冲涡流应力检测研究进展

    Institute of Scientific and Technical Information of China (English)

    周德强; 田贵云; 尤丽华; 王海涛

    2011-01-01

    Directional pulsed eddy current testing(PECT) technology is a new type of pulsed eddy current testing technology. Because of the directional characteristics. It has previous performance in strain testing in anisotropic metal components. The recent research progress including the theory, feature extraction, and strain test of anisotropic metal components of directional pulsed eddy current nondestructive test are reviewed. The future trend of development is analyzed.%方向性脉冲涡流检测技术是一种新型的脉冲涡流检测技术,由于具有方向特性,在脉冲涡流各向异性金属部件应力检测中具有明显的优越性.综述了方向性脉冲涡流无损检测技术在理论、信号特征提取、应力检测等方面的国内外研究进展,分析了方向性脉冲涡流无损检测技术的发展方向.

  3. All-solid-state repetitive semiconductor opening switch-based short pulse generator.

    Science.gov (United States)

    Ding, Zhenjie; Hao, Qingsong; Hu, Long; Su, Jiancang; Liu, Guozhi

    2009-09-01

    The operating characteristics of a semiconductor opening switch (SOS) are determined by its pumping circuit parameters. SOS is still able to cut off the current when pumping current duration falls to the order of tens of nanoseconds and a short pulse forms simultaneously in the output load. An all-solid-state repetitive SOS-based short pulse generator (SPG100) with a three-level magnetic pulse compression unit was successfully constructed. The generator adopts magnetic pulse compression unit with metallic glass and ferrite cores, which compresses a 600 V, 10 mus primary pulse into short pulse with forward pumping current of 825 A, 60 ns and reverse pumping current of 1.3 kA, 30 ns. The current is sent to SOS in which the reverse pumping current is interrupted. The generator is capable of providing a pulse with the voltage of 120 kV and duration of 5-6 ns while output load being 125 Omega. The highest repetition rate is up to 1 kHz.

  4. Effect of continuous and pulsed currents on microstructural evolution of stainless steel joined by TIG welding; Einfluss des Einsatzes von Dauerstrom und Impulsstrom auf die Mikrostrukturentwicklung bei durch das WIG-Schweissverfahren gefuegtem rostfreiem Stahl

    Energy Technology Data Exchange (ETDEWEB)

    Durgutlu, Ahmet; Findik, Tayfun; Guelenc, Behcet [Gazi Univ., Ankara (Turkey). Dept. of Metallurgy and Materials Engineering; Cevik, Bekir [Duezce Univ. (Turkey). Dept. of Welding Technology; Kaya, Yakup; Kahraman, Nizamettin [Karabuek Univ. (Turkey). Dept. of Manufacturing Engineering

    2015-07-01

    In this study, AISI 316L series austenitic stainless steel sheets were joined by tungsten inert gas welding method in continuous and pulsed currents. Regarding microstructural investigation and hardness values of weld metal, samples were welded to investigate the effect of current type on grain structures of weld metal. Results showed that samples welded by using pulsed current had considerable different properties compared to the samples welded by using continuous current. While the weld metals of joinings obtained by using continuous current displayed a coarse-grained and columnar structure, weld metals obtained by using pulsed current had a finer-grained structure. It was also found that hardness values of samples, which were welded with continuous and pulsed current, were quite different.

  5. Study on the nanostructure formation mechanism of hypereutectic Al–17.5Si alloy induced by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Bo, E-mail: gaob@smm.neu.edu.cn [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Hu, Liang [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Li, Shi-wei [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Faculty of Metallurgical and Energy Engineering, Kunming University of Science and Technology, Kunming 650093 (China); Hao, Yi [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Zhang, Yu-dong [Laboratoire d’Etude des Textures et Applications aux Matériaux (LETAM, UMR-CNRS 7078), Université Paul Verlaine de Metz, Ile du Saulcy, Metz 57012 (France); Tu, Gan-feng [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Grosdidier, Thierry [Laboratoire d’Etude des Textures et Applications aux Matériaux (LETAM, UMR-CNRS 7078), Université Paul Verlaine de Metz, Ile du Saulcy, Metz 57012 (France)

    2015-08-15

    This work investigates the nanostructure forming mechanism of hypereutectic Al–17.5Si alloy associated with the high current pulsed electron beam (HCPEB) treatment with increasing number of pulses by electron backscatter diffraction (EBSD) and SEM. The surface layers were melted and resolidified rapidly. The treated surfaces show different structural characteristics in different compositions and distribution zones. The top melted-layer zone can be divided into three zones: Si-rich, Ai-rich, and intermediate zone. The Al-rich zone has a nano-cellular microstructure with a diameter of ∼100 nm. The microstructure in the Si-rich zone consists of fine, dispersive, and spherical nano-sized Si crystals surrounded by α(Al) cells. Some superfine eutectic structures form in the boundary of the two zones. With the increase of number of pulses, the proportion of Si-rich zone to the whole top surface increases, and more cellular substructures are transformed to fine equiaxed grain. In other words, with increasing number of pulses, more Si elements diffuse to the Al-rich zone and provide heterogeneous nucleation sites, and Al grains are refined dramatically. Moreover, the relationship between the substrate Si phase and crystalline phase is determined by EBSD; that is, (1 1 1){sub Al}//(0 0 1){sub Si} with a value of disregistry δ at approximately 5%. The HCPEB technique is a versatile technique for refining the surface microstructure of hypereutectic Al–Si alloys.

  6. Design and testing of a 320 MW pulsed power supply

    Energy Technology Data Exchange (ETDEWEB)

    Schillig, J.B.; Boenig, H.J. [Los Alamos National Lab., NM (United States); Ferner, J.A. [National High Magnetic Field Lab., Tallahassee, FL (United States)] [and others

    1998-03-01

    For a 60 Tesla, 100 millisecond long pulse magnet five 64 MW (87.6 MVA) power converter modules have been installed. Each module provides a no-load voltage of 4.18 kV and a full load voltage of 3.20 kV at the rated current of 20 kA. The modules are connected to a 1,430 MVA/650 MJ inertial energy storage generator set, which is operated at 21 kV and frequencies between 60 and 42 Hz. They are designed to provide the rated power output for 2 seconds once every hour. Each module consists of two 21 kV/3.1 kV cast coil transformers and two 6-pulse rectifiers connected in parallel without an interphase reactor, forming a 12-pulse converter module. As far as possible standard high power industrial converter components were used, operated closer to their allowable limits. The converters are controlled by three programmable high speed controllers. In this paper the design of the pulsed converters, including control and special considerations for protection schemes with the converters supplying a mutually coupled magnet system, is detailed. Test results of the converters driving an ohmic-inductive load for 2 seconds at 20 kA and 3.2 kV are presented.

  7. High Througput pKa Prediction Using Semi Empirical Methods

    CERN Document Server

    Jensen, Jan H

    2015-01-01

    A large proportion of organic molecules relevant to medicine and biotechnology contain one or more ionizable groups, which means that fundamental physical and chemical properties (e.g. the charge of the molecule) depend on the pH of the surroundings via the corresponding pKa values of the molecules. As drug- and material design increasingly is being done through high throughput screens, fast - yet accurate - computational pKa prediction methods are becoming crucial to the design process. Current empirical pKa predictors are increasingly found to fail because they are being applied to parts of chemical space for which experimental parameterization data is lacking. We propose to develop a pKa predictor that, due its quantum mechanical foundation, is more generally applicable but still fast enough to be used in high throughput screening. The method has the potential to impact virtually any biotechnological design process involving organic molecules as we will demonstrate for metabolic engineering and organic bat...

  8. Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

    Science.gov (United States)

    Verma, Rishi; Mishra, Ekansh; Dhang, Prosenjit; Sagar, Karuna; Meena, Manraj; Shyam, Anurag

    2016-09-01

    The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ˜10 kJ is segregated into four modules of ˜2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA-600 kA (corresponding to charging voltage range of 14 kV-18 kV) in a quarter time period of ˜2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar-11 mbar at ˜17 kV/550 kA discharge. At ˜7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ˜4 × 109 neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ˜2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

  9. STARLITE figures of merit for tokamak current drive -- Economic analysis of pulsed and steady state power plants with various engineering and physics performance parameters

    Energy Technology Data Exchange (ETDEWEB)

    Ehst, D.A. [Argonne National Lab., IL (United States); Jardin, S.; Kessel, C. [Princeton Univ., NJ (United States). Plasma Physics Lab.

    1995-10-01

    The physics efficiency of current drive ({gamma}{sub B} {proportional_to} n{sub e} I{sub 0} R{sub 0}/P{sub CD}), including the bootstrap effect, needs to exceed certain goals in order to provide economical steady state operation compared to pulsed power plants. The goal for {gamma}{sub B} depends not only on engineering performance of the current drive system, but also on normalized beta and the effective safety factor of the achievable MHD equilibrium.

  10. Starlite figures of merit for tokamak current drive - economic analysis of pulsed and steady state power plants with various engineering and physics performance parameters

    Energy Technology Data Exchange (ETDEWEB)

    Ehst, D.A.

    1995-09-01

    The physics efficiency of current drive ({gamma}{sub B} {proportional_to} n{sub e} I{sub o} R{sub o}/P{sub CD}), including the bootstrap effect, needs to exceed certain goals in order to provide economical steady state operation compared to pulsed power plants. The goal for {gamma}{sub B} depends not only on engineering performance of the current drive system, but also on normalized beta and the effective safety factor of the achievable MHD equilibrium.

  11. Pulsed Eddy Current Detecting System Based on DDS%基于DDS技术的脉冲涡流检测系统

    Institute of Scientific and Technical Information of China (English)

    宋琦华; 毛义梅; 雷华明

    2011-01-01

    The pulsed eddy current detecting technology is a new branch of the eddy current nondestructive testing and can detect the de-fects in the metal conductor equipments quickly and easily. Based on the characteristics of the pulsed signal generator, a pulsed eddy current detecting system with parameters adjustable pulsed signal generator, using direct frequency synthesis technology, was designed. The PEC testing system is combined of hardware circuit, PC, data acquisition card and relevant software components. With AD9850, a square wave of 1kHz is generated as excitation of defect detection experiment from which eigenvalues are calculated and identification of three quantitative PEC defects were discussed.%脉冲涡流检测技术作为当前无损检测技术中的一种新技术,能够快速方便地检测金属构件中的缺陷;文中根据脉冲涡流检测信号源的特点,采用Direct Digital Frequency Synthesis(直接数字频率合成,简称DDS)技术,设计了一种参数可调式脉冲波形信号源的脉冲涡流检测系统;系统由脉冲涡流检测硬件电路、上位机、数据采集卡和相关软件组成;最后使用AD9850芯片产生1kHz、50%占空比的方波激励对标准缺陷试件进行实验,并提取特征值对试件的三种定量缺陷区分进行了研究.

  12. Simultaneously Excitatory and Inhibitory Effects of Transcranial Alternating Current Stimulation Revealed Using Selective Pulse-Train Stimulation in the Rat Motor Cortex.

    Science.gov (United States)

    Khatoun, Ahmad; Asamoah, Boateng; Mc Laughlin, Myles

    2017-09-27

    Transcranial alternating current stimulation (tACS) uses sinusoidal, subthreshold, electric fields to modulate cortical processing. Cortical processing depends on a fine balance between excitation and inhibition and tACS acts on both excitatory and inhibitory cortical neurons. Given this, it is not clear whether tACS should increase or decrease cortical excitability. We investigated this using transcranial current stimulation of the rat (all males) motor cortex consisting of a continuous subthreshold sine wave with short bursts of suprathreshold pulse-trains inserted at different phases to probe cortical excitability. We found that when a low-rate, long-duration, suprathreshold pulse-train was used, subthreshold cathodal tACS decreased cortical excitability and anodal tACS increased excitability. However, when a high-rate, short-duration, suprathreshold pulse-train was used this pattern was inverted. An integrate-and-fire model incorporating biophysical differences between cortical excitatory and inhibitory neurons could predict the experimental data and helped interpret these results. The model indicated that low-rate suprathreshold pulse-trains preferentially stimulate excitatory cortical neurons, whereas high-rate suprathreshold pulse-trains stimulate both excitatory and inhibitory neurons. If correct, this indicates that suprathreshold pulse-train stimulation may be able to selectively control the excitation-inhibition balance within a cortical network. The excitation-inhibition balance then likely plays an important role in determining whether subthreshold tACS will increase or decrease cortical excitability.SIGNIFICANCE STATEMENT Transcranial alternating current stimulation (tACS) is a noninvasive neuromodulation method that uses weak sinusoidal electric fields to modulate cortical activity. In healthy volunteers tACS can modulate perception, cognition, and motor function but the underlying neural mechanism is poorly understood. In this study, using rat motor

  13. Coherent π-electron dynamics of (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses: angular momentum and ring current.

    Science.gov (United States)

    Mineo, H; Lin, S H; Fujimura, Y

    2013-02-21

    The results of a theoretical investigation of coherent π-electron dynamics for nonplanar (P)-2,2'-biphenol induced by ultrashort linearly polarized UV pulses are presented. Expressions for the time-dependent coherent angular momentum and ring current are derived by using the density matrix method. The time dependence of these coherences is determined by the off-diagonal density matrix element, which can be obtained by solving the coupled equations of motion of the electronic-state density matrix. Dephasing effects on coherent angular momentum and ring current are taken into account within the Markov approximation. The magnitudes of the electronic angular momentum and current are expressed as the sum of expectation values of the corresponding operators in the two phenol rings (L and R rings). Here, L (R) denotes the phenol ring in the left (right)-hand side of (P)-2,2'-biphenol. We define the bond current between the nearest neighbor carbon atoms Ci and Cj as an electric current through a half plane perpendicular to the Ci-Cj bond. The bond current can be expressed in terms of the inter-atomic bond current. The inter-atomic bond current (bond current) depends on the position of the half plane on the bond and has the maximum value at the center. The coherent ring current in each ring is defined by averaging over the bond currents. Since (P)-2,2'-biphenol is nonplanar, the resultant angular momentum is not one-dimensional. Simulations of the time-dependent coherent angular momentum and ring current of (P)-2,2'-biphenol excited by ultrashort linearly polarized UV pulses are carried out using the molecular parameters obtained by the time-dependent density functional theory (TD-DFT) method. Oscillatory behaviors in the time-dependent angular momentum (ring current), which can be called angular momentum (ring current) quantum beats, are classified by the symmetry of the coherent state, symmetric or antisymmetric. The bond current of the bridge bond linking the L and R

  14. 13 kA Superconducting Busbars Manufacturing Process

    CERN Document Server

    Principe, R; Fornasiere, E

    2012-01-01

    In the LHC, the superconducting Main Bending magnets and Quadrupole magnets are series-connected electrically in different excitation circuits by means of superconducting busbars, carrying a maximum current of 13 kA. These superconducting busbars consist of a superconducting Rutherford cable thermally and electrically coupled to a copper section all along the length. The function of the copper section is essentially to provide an alternative path for the magnet current in case of resistive transition. The production of these components was originally outsourced. The decision to import the technology at CERN led to a global re-engineering of the standard process. Although based on the procedures adopted during the LHC construction, a few modifications and improvements have been implemented, profiting of the experience gained in the last few years. This document details the manufacturing process of the 13 kA busbars as it is actually performed at CERN, emphasizing the new solutions adopted during the first mon...

  15. NASA's Evolution to Ka-Band Space Communications for Near-Earth Spacecraft

    Science.gov (United States)

    McCarthy, Kevin; Stocklin, Frank; Geldzahler, Barry; Friedman, Daniel; Celeste, Peter

    2010-01-01

    This slide presentation reviews the exploration of NASA using a Ka-band system for spacecraft communications in Near-Earth orbits. The reasons for changing to Ka-band are the higher data rates, and the current (X-band spectrum) is becoming crowded. This will require some modification to the current ground station antennas systems. The results of a Request for Information (RFI) are discussed, and the recommended solution is reviewed.

  16. The structural properties of CdS deposited by chemical bath deposition and pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lisco, F., E-mail: F.Lisco@lboro.ac.uk [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom); Kaminski, P.M.; Abbas, A.; Bass, K.; Bowers, J.W.; Claudio, G. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, via Orabona 4, 70126 Bari (Italy); Walls, J.M. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom)

    2015-05-01

    Cadmium sulphide (CdS) thin films were deposited by two different processes, chemical bath deposition (CBD), and pulsed DC magnetron sputtering (PDCMS) on fluorine doped-tin oxide coated glass to assess the potential advantages of the pulsed DC magnetron sputtering process. The structural, optical and morphological properties of films obtained by CBD and PDCMS were investigated using X-ray photoelectron spectroscopy, X-ray diffraction, scanning and transmission electron microscopy, spectroscopic ellipsometry and UV-Vis spectrophotometry. The as-grown films were studied and comparisons were drawn between their morphology, uniformity, crystallinity, and the deposition rate of the process. The highest crystallinity is observed for sputtered CdS thin films. The absorption in the visible wavelength increased for PDCMS CdS thin films, due to the higher density of the films. The band gap measured for the as-grown CBD-CdS is 2.38 eV compared to 2.34 eV for PDCMS-CdS, confirming the higher density of the sputtered thin film. The higher deposition rate for PDCMS is a significant advantage of this technique which has potential use for high rate and low cost manufacturing. - Highlights: • Pulsed DC magnetron sputtering (PDCMS) of CdS films • Chemical bath deposition of CdS films • Comparison between CdS thin films deposited by chemical bath and PDCMS techniques • High deposition rate deposition for PDCMS deposition • Uniform, pinhole free CdS thin films.

  17. Ultrafast spintronics roadmap: from femtosecond spin current pulses to terahertz non-uniform spin dynamics via nano-confined spin transfer torques (Conference Presentation)

    Science.gov (United States)

    Melnikov, Alexey; Razdolski, Ilya; Alekhin, Alexandr; Ilin, Nikita; Meyburg, Jan; Diesing, Detlef; Roddatis, Vladimir; Rungger, Ivan; Stamenova, Maria; Sanvito, Stefano; Bovensiepen, Uwe

    2016-10-01

    Further development of spintronics requires miniaturization and reduction of characteristic timescales of spin dynamics combining the nanometer spatial and femtosecond temporal ranges. These demands shift the focus of interest towards the fundamental open question of the interaction of femtosecond spin current (SC) pulses with a ferromagnet (FM). The spatio-temporal properties of the spin transfer torque (STT) exerted by ultrashort SC pulses on the FM open the time domain for studying STT fingerprint on spatially non-uniform magnetization dynamics. Using the sensitivity of magneto-induced second harmonic generation to SC, we develop technique for SC monitoring. With 20 fs resolution, we demonstrate the generation of 250 fs-long SC pulses in Fe/Au/Fe/MgO(001) structures. Their temporal profile indicates (i) nearly-ballistic hot electron transport in Au and (ii) that the pulse duration is primarily determined by the thermalization time of laser-excited hot carriers in Fe. Together with strongly spin-dependent Fe/Au interface transmission calculated for these carriers, this suggests the non-thermal spin-dependent Seebeck effect dominating the generation of ultrashort SC pulses. The analysis of SC transmission/reflection at the Au/Fe interface shows that hot electron spins orthogonal to the Fe magnetization rotate gaining huge parallel (anti-parallel) projection in transmitted (reflected) SC. This is accompanied by a STT-induced perturbation of the magnetization localized at the interface, which excites the inhomogeneous high-frequency spin dynamics in the FM. Time-resolved magneto-optical studies reveal the excitation of several standing spin wave modes in the Fe film with their spectrum extending up to 0.6 THz and indicating the STT spatial confinement to 2 nm.

  18. Geological record of meltwater events at Qinghai Lake, China from the past 40 ka

    Science.gov (United States)

    Zhou, Weijian; Liu, Taibei; Wang, Hao; An, Zhisheng; Cheng, Peng; Zhu, Yizhi; Burr, G. S.

    2016-10-01

    We report here on a previously unpublished sediment core from Qinghai Lake, China, that preserves a continuous record of sedimentation for the past 40 ka. A striking feature of the record is a set of distinct meltwater events recorded at 35, 19 and 14 ka respectively. These events are manifest as distinct pulses of relatively old organic radiocarbon in the sediments. We interpret these as a signal of glacial melting in the Qinghai Lake watershed. The meltwater signals are closely correlated to temperature and precipitation records associated with deglaciation. The events at 19 ka and 14 ka correspond to well-established high latitude Melt Water Pulse (MWP) events during Marine Isotope Stage (MIS) 2, and the 35 ka event corresponds to a period of pervasive high lake levels in western China during late MIS 3. We interpret these anomalous dates as the result of relatively old carbon that was destabilized by the glaciers, and released into the lake as the glaciers melted. The data indicate that this process takes thousands of years. We expect that the approach employed here to identify these events is generally applicable to any lake system with a significant glacial meltwater component.

  19. Microstructure changes during non-conventional heat treatment of thin Ni-Ti wires by pulsed electric current studied by transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Delville, R., E-mail: remi.delville@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Malard, B.; Pilch, J.; Sittner, P. [Institute of Physics, Na Slovance 2, 182 21 Praha (Czech Republic); Schryvers, D. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2010-08-15

    Transmission electron microscopy, electrical resistivity measurements and mechanical testing were employed to investigate the evolution of microstructure and functional superelastic properties of 0.1 mm diameter as-drawn Ni-Ti wires subjected to a non-conventional heat treatment by controlled electric pulse currents. This method enables a better control of the recovery and recrystallization processes taking place during the heat treatment and accordingly a better control on the final microstructure. Using a stepwise approach of millisecond pulse annealing, it is shown how the microstructure evolves from a severely deformed state with no functional properties to an optimal nanograined microstructure (20-50 nm) that is partially recovered through polygonization and partially recrystallized and that has the best functional properties. Such a microstructure is highly resistant against dislocation slip upon cycling, while microstructures annealed for longer times and showing mostly recrystallized grains were prone to dislocation slip, particularly as the grain size exceeds 200 nm.

  20. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality...... a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, an anthropomorfized archive of a past intimacy and an all-encompassing immersive environment modulating continuously in real space-time....

  1. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    Science.gov (United States)

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  2. The Recent Developments of Pulsed Eddy Current Nondestructive Testing Technology%脉冲涡流无损检测技术的研究进展

    Institute of Scientific and Technical Information of China (English)

    周德强; 田贵云; 王海涛; 尤丽华

    2011-01-01

    Pulsed eddy current testing(PECT) is a new eddy current testing technology. As the wide spectrum of the excited current or voltage, it is widely used in aerospace, pressure vessels, railways, pipe and so on. The recently research progress including the defect of metal, stress of components, and thermal imaging of pulsed eddy current were discussed. The future trend of development was analyzed.%脉冲涡流检测技术是涡流检测技术的一个新兴分支,其宽频谱的激励方式使得脉冲涡流检测技术在航空航天、压力容器、铁路和管道等领域广泛应用。综述了脉冲涡流检测技术在金属缺陷、应力和热成像等方面的国内外研究进展,分析了脉冲涡流检测技术的发展方向。

  3. Design of a pulse-triggered four-channel functional electrical stimulator using complementary current source and time division multiplexing output method.

    Science.gov (United States)

    Wang, Hai-Peng; Wang, Zhi-Gong; Lü, Xiao-Ying; Huang, Zong-Hao; Zhou, Yu-Xuan

    2015-08-01

    In this paper, a four-channel pulse-triggered functional electrical stimulator using complementary current source and time division output method is proposed for the research and application of functional electrical stimulation (FES). The high-voltage compliance and output impedance is increased by adopting the complementary current source, which can also realize the linear voltage-to-current conversion and high channel isolation. A high-voltage analog switch chip MAX14803, combined with a FIFO queue algorithm in the microprocessor, is used to setup the H-bridge and multiplexers for the four-channel time division multiplexing output. With this method, the size and cost of the key components are reduced greatly. The stimulating core circuit area is 30 × 50 mm(2). According to the experiments, the stimulator can achieve the four-channel charge-balanced biphasic stimulation with a current range between 0 and 60 mA and a single-phase pulse amplitude up to 60 V.

  4. Temperature Distribution Analysis of JAERI 60 kA HTS Lead

    Institute of Scientific and Technical Information of China (English)

    FUYoukun; T.Isono

    2003-01-01

    High temperature suprerconductor (HTS)current lead has an advantage in reducing electric power consumption of a refrigerator for a large current superconducting magnet system such as a fusion device. A fusion device requires more than 20 pairs of large current leads and each current capacity is about 60 kA. The conventional 60 kA current lead needs 100 kW electric power for refrigeration and a 2/3 reduction is available by the application of a HTS current lead.

  5. The 40 kA dumping system for the ISR beams

    CERN Document Server

    Schnuriger, J C

    1975-01-01

    It has been necessary to build a fast and reliable system which can dump the beam whenever safety monitors indicate a hardware fault or a beam loss. The beam in each ISR is dumped by means of four fast pulsed magnets deflecting the particles vertically onto an absorber block situated in the same long straight section. The 0.75 Omega , 40 kA pulse generator now energizing the four fast pulsed magnets is described with special attention to the principles and technological solutions which were adopted in order to achieve the necessary reliability of the system for each type of operation, and particularly during long colliding beam experiments. (7 refs).

  6. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  7. Design of a Compact Pulsed Power Accelerator

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    A 100 kA/60 ns compact pulsed power accelerator was designed to study the influence to the X-pinch by the load. It is composed of a Marx generator, a combined pulse forming (PFL), a gas-filled V/N field distortion switch, a transfer line,

  8. New digital techniques applied to A and Z identification using pulse shape discrimination of silicon detector current signals

    Energy Technology Data Exchange (ETDEWEB)

    Barlini, S. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France)], E-mail: barlini@fi.infn.it; Bougault, R.; Laborie, Ph.; Lopez, O.; Mercier, D. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); Parlog, M. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); NIPNE, RO-76900 Bucharest (Romania); Tamain, B.; Vient, E. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); Chevallier, E.; Chbihi, A.; Jacquot, B. [GANIL, CEA/DSM-CNRS/IN2P3, Caen (France); Kravchuk, V.L. [INFN-LNL, I-35020 Legnaro, Padova (Italy)

    2009-03-11

    Extending pulse shape discrimination (PSD) to digitized signals is one of the most promising methods to identify particles stopped in a detector. Using the CIME accelerator in the GANIL laboratory, a measurement campaign was done to collect data corresponding to different charges, masses and energies of implanted ions. These data are used to develop an algorithm capable to discriminate the different particles both in mass and charge. In this experiment, a 300{mu}m n-TD reverse mounted Si detector was used. These studies on PSD are part of the FAZIA R and D, a research and development project aiming at building a new 4{pi} array for isospin nuclear physics.

  9. Anti-fatigue effect of percutaneous stimulation of the hepatic region by mid-frequency pulse current in different diadynamic cycles in soldiers with exercise-induced fatigue

    Directory of Open Access Journals (Sweden)

    Peng-yi DAI

    2012-01-01

    Full Text Available Objective  To investigate the anti-fatigue effect of percutaneous stimulation of the hepatic region with the mid-frequency pulse current in different diadynamic cycles in exercise-induced fatigued soldiers. Methods  One hundred twenty healthy PLA recruits who did not have physical exercise were randomly divided into four groups with thirty ones in each: control, stimulation group A, stimulation group B, and stimulation group C. All the subjects of four groups were ordered intensive training (exercise from Monday to Saturday, with rest on Sunday for five weeks to establish the exercise-induced fatigue model. Each day after the exercise, the recruits of stimulation groups A, B, and C were treated immediately with mid-frequency (1204Hz, current intensity ≤80mA stimulation to the hepatic region with diadynamic cycles of 0.5, 1, and 2 seconds, respectively. No pulse current stimulation was given in the control group. Venous blood was collected before breakfast on Sundays to measure the fasting plasma glucose (FPG and blood lactate (LAC contents, and liver function was determined by determination of alanine aminotransferase (ALT, aspartate aminotransferase (AST, and lactate dehydrogenase (LDH. The 3000-m running performance of the recruits in each group was recorded on the same day. Results  There was no significant difference between the four groups in terms of the FPG level at the end of the first week (P>0.05. At the end of the third and fifth weeks, the FPG level was significantly higher in the three stimulation groups than in the control group (PPP>0.05. At the end of the first, third, and fifth weeks, the ALT, AST, LDH, and LAC levels were significantly lower in every stimulation group than in the control group (PPPPP>0.05. At the end of the first week, there was no significant difference in 3000-m running performance (P>0.05 between the 4 groups. At the end of the third and fifth weeks, the 3000-m running performance was significantly

  10. AltiKa in-flight performances

    Science.gov (United States)

    Boy, Francois; Desjonquères, Jean-Damien; Steunou, Nathalie

    2015-04-01

    The SARAL/AltiKa satellite has been launched the 25th of February 2013 from the launch pad of Sriharikota (India). Since this date, AltiKa provides measurements and affords the first altimetry results in Ka band. This paper recalls the instrument design and assesses the in-flight performance. The SARAL/AltiKa mission has been developed in the frame of a cooperation between CNES (French Space Agency) and ISRO (Indian Space Research Organization). AltiKa is a single frequency Ka-band altimeter with a bi-frequency radiometer embedded. Both altimeter and radiometer share the same antenna. Altimeter expertise and routine calibrations performed during assessment phase demonstrate the stability of the instrument. Moreover the performance assessed over ocean are noteworthy such as 0.9 cm on epoch 1 Hz noise for 2 m of SWH, which is fully consistent with simulations and ground pre-flight tests results. The data availability is also very good and very few altimeter measurements are lost due to rain attenuation. Radiometer data analysis shows that the instrument is very stable and its performances are consistent with pre-flight tests results.

  11. Ionization constants pKa of cardiolipin.

    Directory of Open Access Journals (Sweden)

    Gerd Olofsson

    Full Text Available Cardiolipin is a phospholipid found in the inner mitochondrial membrane and in bacteria, and it is associated with many physiological functions. Cardiolipin has a dimeric structure consisting of two phosphatidyl residues connected by a glycerol bridge and four acyl chains, and therefore it can carry two negative charges. The pKa values of the phosphate groups have previously been reported to differ widely with pKa1 = 2.8 and pKa2 = 7.5-9.5. Still, there are several examples of experimental observations from cardiolipin-containing systems that do not fit with this dissociation behavior. Therefore, we have carried out pH-titration and titration calorimetric experiments on two synthetic cardiolipins, 1,1',2,2'-tetradecanoyl cardiolipin, CL (C14:0, and 1,1',2,2'-tetraoctadecenoyl cardiolipin, CL (C18:1. Our results show that both behave as strong dibasic acids with pKa1 about the same as the first pKa of phosphoric acid, 2.15, and pKa2 about one unit larger. The characterization of the acidic properties of cardiolipin is crucial for the understanding of the molecular organization in self-assembled systems that contain cardiolipin, and for their biological function.

  12. Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse

    Directory of Open Access Journals (Sweden)

    Paolo Zamboni

    2016-01-01

    Full Text Available Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average velocity with the cross-sectional area (CSA. However, also the quantification protocols lacked of the necessary accuracy. The reasons are as follows: (a automatic measurement of the CSA assimilates the jugular to a circle, while it is elliptical; (b the use of just a single CSA value in a pulsatile vessel is inaccurate; (c time average velocity assessment can be applied only in laminar flow. Finally, the tutorial describes alternative ultrasound calculation of flow based on the Womersley method, which takes into account the variation of the jugular CSA overtime. In the near future, it will be possible to synchronize the electrocardiogram with the brain inflow (carotid distension wave and with the outflow (jugular venous pulse in order to nicely have a noninvasive ultrasound picture of the brain-heart axis. US jugular venous pulse may have potential use in neurovascular, neurocognitive, neurosensorial, and neurodegenerative disorders.

  13. Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse.

    Science.gov (United States)

    Zamboni, Paolo

    2016-01-01

    Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average velocity with the cross-sectional area (CSA). However, also the quantification protocols lacked of the necessary accuracy. The reasons are as follows: (a) automatic measurement of the CSA assimilates the jugular to a circle, while it is elliptical; (b) the use of just a single CSA value in a pulsatile vessel is inaccurate; (c) time average velocity assessment can be applied only in laminar flow. Finally, the tutorial describes alternative ultrasound calculation of flow based on the Womersley method, which takes into account the variation of the jugular CSA overtime. In the near future, it will be possible to synchronize the electrocardiogram with the brain inflow (carotid distension wave) and with the outflow (jugular venous pulse) in order to nicely have a noninvasive ultrasound picture of the brain-heart axis. US jugular venous pulse may have potential use in neurovascular, neurocognitive, neurosensorial, and neurodegenerative disorders.

  14. Optimization of pulsed current GTAW process parameters for sintered hot forged AISI 4135 P/M steel welds by simulated annealing and genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, Joby; Muthukumaran, S. [National Institute of Technology, Tamil Nadu (India)

    2016-01-15

    Abundant improvements have occurred in materials handling, especially in metal joining. Pulsed current gas tungsten arc welding (PCGTAW) is one of the consequential fusion techniques. In this work, PCGTAW of AISI 4135 steel engendered through powder metallurgy (P/M) has been executed, and the process parameters have been highlighted applying Taguchi's L9 orthogonal array. The results show that the peak current (Ip), gas flow rate (GFR), welding speed (WS) and base current (Ib) are the critical constraints in strong determinant of the Tensile strength (TS) as well as percentage of elongation (% Elong) of the joint. The practical impact of applying Genetic algorithm (GA) and Simulated annealing (SA) to PCGTAW process has been authenticated by means of calculating the deviation between predicted and experimental welding process parameters.

  15. Particle-in-cell simulation of electron trajectories and irradiation uniformity in an annular cathode high current pulsed electron beam source

    Science.gov (United States)

    Jiang, Wei; Wang, Langping; Zhou, Guangxue; Wang, Xiaofeng

    2017-02-01

    In order to study electron trajectories in an annular cathode high current pulsed electron beam (HCPEB) source based on carbon fiber bunches, the transmission process of electrons emitted from the annular cathode was simulated using a particle-in-cell model with Monte Carlo collisions (PIC-MCC). The simulation results show that the intense flow of the electrons emitted from the annular cathode are expanded during the transmission process, and the uniformity of the electron distribution is improved in the transportation process. The irradiation current decreases with the irradiation distance and the pressure, and increases with the negative voltage. In addition, when the irradiation distance and the cathode voltage are larger than 40 mm and -15 kV, respectively, a uniform irradiation current distribution along the circumference of the anode can be obtained. The simulation results show that good irradiation uniformity of circular components can be achieved by this annular cathode HCPEB source.

  16. Fiber transmission and generation of ultrawideband pulses by direct current modulation of semi-conductor lasers and chirp-to-intensity conversion

    DEFF Research Database (Denmark)

    Company Torres, Victor; Prince, Kamau; Tafur Monroy, Idelfonso

    2008-01-01

    Optical pulses generated by current modulation of semiconductor lasers are strongly frequency chirped. This effect has been considered pernicious for optical communications. We take advantage of this effect for the generation of ultrawideband microwave signals by using an optical filter to achieve...... chirp-to-intensity conversion. We also experimentally achieve propagation through a 20 km nonzero dispersion shifted fiber with no degradation of the signal at the receiver. Our method constitutes a prospective low-cost solution and offers integration capabilities with fiber...

  17. Time-domain measurement of terahertz frequency magnetoplasmon resonances in a two-dimensional electron system by the direct injection of picosecond pulsed currents

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jingbo; Mayorov, Alexander S.; Wood, Christopher D.; Mistry, Divyang; Li, Lianhe; Linfield, Edmund H.; Giles Davies, A.; Cunningham, John E., E-mail: j.e.cunningham@leeds.ac.uk [School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT (United Kingdom); Sydoruk, Oleksiy [Optical and Semiconductor Devices Group, Department of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom)

    2016-02-29

    We have investigated terahertz (THz) frequency magnetoplasmon resonances in a two-dimensional electron system through the direct injection of picosecond duration current pulses. The evolution of the time-domain signals was measured as a function of magnetic field, and the results were found to be in agreement with calculations using a mode-matching approach for four modes observed in the frequency range above 0.1 THz. This introduces a generic technique suitable for sampling ultrafast carrier dynamics in low-dimensional semiconductor nanostructures at THz frequencies.

  18. AltiKa: a Ka-band Altimetry Payload and System for Operational Altimetry during the GMES Period

    Science.gov (United States)

    Vincent, Patrick; Steunou, Nathalie; Caubet, Eric; Phalippou, Laurent; Rey, Laurent; Thouvenot, Eric; Verron, Jacques

    2006-01-01

    This paper describes the Ka-band altimetry payload and system that has been studied for several years by CNES, ALCATEL SPACE and some science laboratories. Altimetry is one of the major elements of the ocean observing system to be made sustainable through the GEOSS (Global Earth Observation System of Systems) and GMES (Global Monitoring of the Environment and Security) programs. A short review of some mission objectives to be fulfilled in terms of mesoscale oceanography in the frame of the GEOSS and GMES programs is performed. To answer the corresponding requirements, the approach consisting in a constellation of nadir altimeter is discussed. A coupled Ka-band altimeter-radiometer payload is then described; technical items are detailed to explain how this payload shall meet the science and operational requirements, and expected performances are displayed. The current status of the payload development and flight perspectives are given.

  19. AltiKa: a Ka-band Altimetry Payload and System for Operational Altimetry during the GMES Period

    Directory of Open Access Journals (Sweden)

    Jacques Verron

    2006-03-01

    Full Text Available This paper describes the Ka-band altimetry payload and system that has beenstudied for several years by CNES, ALCATEL SPACE and some science laboratories.Altimetry is one of the major elements of the ocean observing system to be madesustainable through the GEOSS (Global Earth Observation System of Systems and GMES(Global Monitoring of the Environment and Security programs. A short review of somemission objectives to be fulfilled in terms of mesoscale oceanography in the frame of theGEOSS and GMES programs is performed. To answer the corresponding requirements, theapproach consisting in a constellation of nadir altimeter is discussed. A coupled Ka-bandaltimeter-radiometer payload is then described; technical items are detailed to explain howthis payload shall meet the science and operational requirements, and expectedperformances are displayed. The current status of the payload development and flightperspectives are given.

  20. Eight Pulse Performance of DARHT Axis II - Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, Martin E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-08

    The DARHT-II accelerator produces a 1.65-kA, 17-MeV beam in a 1600-ns pulse. Standard operation of the DARHT Axis II accelerator involves extracting four short pulses from the 1.6 us long macro-pulse produced by the LIA. The four short pulses are extracted using a fast kicker in combination with a quadrupole septum magnet and then transported for several meters to a high-Z material target for conversion to x-rays for radiography. The ability of the DARHT Axis 2 kicker to produce more than the standard four pulse format has been previously demonstrated. This capability was developed to study potential risks associated with beam transport during an initial commissioning phase at low energy (8 MeV) and low current (1.0 kA).The ability of the kicker to deliver more than four pulses to the target has been realized for many years. This note describes the initial results demonstrating this capability.

  1. Behavior of a DC zero-flux current sensor; Magnetic field analysis and comparison with experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Campostrini, P.; Sonato, P. (Istituto Gas Ionizzati del CNR, Padova (IT))

    1991-09-01

    In this paper the magnetic section of the finite-element ANSYS code, and in particular its optimization feature has been used to predict the behaviour of a zero-flux current sensor, briefly described, which is intended to be used in a fusion experiment to measure pulsed currents up to 50 kA, over a bandwidth from DC to 10 k Hz. The computed results fit well with those coming from experimental tests performed on a prototype.

  2. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality......“Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... of the visitor’s beating heart to the blink of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the blinking light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant...

  3. Steady-State Fully Noninductive Current Driven by Electron Cyclotron Waves in a Magnetically Confined Plasma

    Science.gov (United States)

    Sauter, O.; Henderson, M. A.; Hofmann, F.; Goodman, T.; Alberti, S.; Angioni, C.; Appert, K.; Behn, R.; Blanchard, P.; Bosshard, P.; Chavan, R.; Coda, S.; Duval, B. P.; Fasel, D.; Favre, A.; Furno, I.; Gorgerat, P.; Hogge, J.-P.; Isoz, P.-F.; Joye, B.; Lavanchy, P.; Lister, J. B.; Llobet, X.; Magnin, J.-C.; Mandrin, P.; Manini, A.; Marlétaz, B.; Marmillod, P.; Martin, Y.; Mayor, J.-M.; Martynov, A. A.; Mlynar, J.; Moret, J.-M.; Nieswand, C.; Nikkola, P.; Paris, P.; Perez, A.; Pietrzyk, Z. A.; Pitts, R. A.; Pochelon, A.; Pochon, G.; Refke, A.; Reimerdes, H.; Rommers, J.; Scavino, E.; Tonetti, G.; Tran, M. Q.; Troyon, F.; Weisen, H.

    2000-04-01

    A steady-state, fully noninductive plasma current has been sustained for the first time in a tokamak using electron cyclotron current drive only. In this discharge, 123 kA of current have been sustained for the entire gyrotron pulse duration of 2 s. Careful distribution across the plasma minor radius of the power deposited from three 0.5-MW gyrotrons was essential for reaching steady-state conditions. With central current drive, up to 153 kA of current have been fully replaced transiently for 100 ms. The noninductive scenario is confirmed by the ability to recharge the Ohmic transformer. The dependence of the current drive efficiency on the minor radius is also demonstrated.

  4. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  5. Pulse generator with intermediate inductive storage as a lightning simulator

    Science.gov (United States)

    Kovalchuk, B. M.; Kharlov, A. V.; Zherlytsyn, A. A.; Kumpyak, E. V.; Tsoy, N. V.

    2016-06-01

    Compact transportable generators are required for simulating a lightning current pulse for electrical apparatus testing. A bi-exponential current pulse has to be formed by such a generator (with a current rise time of about two orders of magnitude faster than the damping time). The objective of this study was to develop and investigate a compact pulse generator with intermediate inductive storage and a fuse opening switch as a simulator of lightning discharge. A Marx generator (six stages) with a capacitance of 1 μF and an output voltage of 240 kV was employed as primary storage. In each of the stages, two IK-50/3 (50 kV, 3 μF) capacitors are connected in parallel. The generator inductance is 2 μH. A test bed for the investigations was assembled with this generator. The generator operates without SF6 and without oil in atmospheric air, which is very important in practice. Straight copper wires with adjustable lengths and diameters were used for the electro-explosive opening switch. Tests were made with active-inductive loads (up to 0.1 Ω and up to 6.3 μH). The current rise time is lower than 1200 ns, and the damping time can be varied from 35 to 125 μs, following the definition of standard lightning current pulse in the IEC standard. Moreover, 1D MHD calculations of the fuse explosion were carried out self-consistently with the electric circuit equations, in order to calculate more accurately the load pulse parameters. The calculations agree fairly well with the tests. On the basis of the obtained results, the design of a transportable generator was developed for a lightning simulator with current of 50 kA and a pulse shape corresponding to the IEEE standard.

  6. Pulse generator with intermediate inductive storage as a lightning simulator.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Zherlytsyn, A A; Kumpyak, E V; Tsoy, N V

    2016-06-01

    Compact transportable generators are required for simulating a lightning current pulse for electrical apparatus testing. A bi-exponential current pulse has to be formed by such a generator (with a current rise time of about two orders of magnitude faster than the damping time). The objective of this study was to develop and investigate a compact pulse generator with intermediate inductive storage and a fuse opening switch as a simulator of lightning discharge. A Marx generator (six stages) with a capacitance of 1 μF and an output voltage of 240 kV was employed as primary storage. In each of the stages, two IK-50/3 (50 kV, 3 μF) capacitors are connected in parallel. The generator inductance is 2 μH. A test bed for the investigations was assembled with this generator. The generator operates without SF6 and without oil in atmospheric air, which is very important in practice. Straight copper wires with adjustable lengths and diameters were used for the electro-explosive opening switch. Tests were made with active-inductive loads (up to 0.1 Ω and up to 6.3 μH). The current rise time is lower than 1200 ns, and the damping time can be varied from 35 to 125 μs, following the definition of standard lightning current pulse in the IEC standard. Moreover, 1D MHD calculations of the fuse explosion were carried out self-consistently with the electric circuit equations, in order to calculate more accurately the load pulse parameters. The calculations agree fairly well with the tests. On the basis of the obtained results, the design of a transportable generator was developed for a lightning simulator with current of 50 kA and a pulse shape corresponding to the IEEE standard.

  7. The Effect of Constant and Pulsed Current Gas Tungsten Arc Welding on Joint Properties of 2205 Duplex Stainless Steel to 316L Austenitic Stainless Steel

    Science.gov (United States)

    Neissi, R.; Shamanian, M.; Hajihashemi, M.

    2016-05-01

    In this study, dissimilar 316L austenitic stainless steel/2205 duplex stainless steel (DSS) joints were fabricated by constant and pulsed current gas tungsten arc welding process using ER2209 DSS as a filler metal. Microstructures and joint properties were characterized using optical and electron scanning microscopy, tensile, Charpy V-notch impact and micro-hardness tests, and cyclic polarization measurements. Microstructural observations confirmed the presence of chromium nitride and delta ferrite in the heat-affected zone of DSS and 316L, respectively. In addition, there was some deviation in the austenite/ferrite ratio of the surface welding pass in comparison to the root welding pass. Besides having lower pitting potential, welded joints produced by constant current gas tungsten arc welding process, consisted of some brittle sigma phase precipitates, which resulted in some impact energy reduction. The tensile tests showed high tensile strength for the weld joints in which all the specimens were broken in 316L base metal.

  8. Initial measurements of plasma current and electron density profiles using a polarimeter/interferometer (POINT) for long pulse operation in EAST (invited)

    Science.gov (United States)

    Liu, H. Q.; Qian, J. P.; Jie, Y. X.; Ding, W. X.; Brower, D. L.; Zou, Z. Y.; Li, W. M.; Lian, H.; Wang, S. X.; Yang, Y.; Zeng, L.; Lan, T.; Yao, Y.; Hu, L. Q.; Zhang, X. D.; Wan, B. N.

    2016-11-01

    A double-pass, radially viewing, far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique has been implemented for diagnosing the plasma current and electron density profiles in the Experimental Advanced Superconducting Tokamak (EAST). POINT has been operated routinely during the most recent experimental campaign and provides continuous 11 chord line-integrated Faraday effect and density measurement throughout the entire plasma discharge for all heating schemes and all plasma conditions (including ITER relevant scenario development). Reliability of both the polarimetric and interferometric measurements is demonstrated in 25 s plasmas with H-mode and 102 s long-pulse discharges. Current density, safety factor (q), and electron density profiles are reconstructed using equilibrium fitting code (EFIT) with POINT constraints for the plasma core.

  9. Pulse pattern modulated strategy for harmonic current components reduction in three-phase AC-DC converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2015-01-01

    Generated harmonic current as a consequence of employing power electronics converter is known as an important power quality issue in distribution networks. From industry point of view complying with international standards is mandatory, however cost and efficiency are two other important features......, which need to be considered in order to be competitive in the market. Therefore, having a flexibility to meet various requirements imposed by the standard recommendations or costumer needs is at most desirable. This makes the generated harmonic current mitigation a challenging task especially with three......-phase diode bridge rectifier, which still is preferred in many power electronic systems. This paper addresses a novel current modulation strategy using a single-switch boost three-phase diode bridge rectifier. The proposed method can selectively mitigate current harmonics, which makes it suitable...

  10. Pulse Pattern-Modulated Strategy for Harmonic Current Components Reduction in Three-Phase AC–DC Converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2016-01-01

    Generated harmonic current as a consequence of employing power electronics converter is known as an important power quality issue in distribution networks. From industry point of view complying with international standards is mandatory, however cost and efficiency are two other important features......, which need to be considered in order to be competitive in the market. Therefore, having a flexibility to meet various requirements imposed by the standard recommendations or costumer needs is at most desirable. This makes the generated harmonic current mitigation a challenging task especially with three......-phase diode bridge rectifier, which still is preferred in many power electronic systems. This paper addresses a novel current modulation strategy using a single-switch boost three-phase diode bridge rectifier. The proposed method can selectively mitigate current harmonics, which makes it suitable...

  11. Rain Fade Compensation Alternatives for Ka Band Communication Satellites

    Science.gov (United States)

    Acosta, Roberto J.

    1997-01-01

    Future satellite communications systems operating in Ka-band frequency band are subject to degradation produced by the troposphere which is much more severe than those found at lower frequency bands. These impairments include signal absorption by rain, clouds and gases, and amplitude scintillation's arising from refractive index irregularities. For example, rain attenuation at 20 GHz is almost three times that at 11 GHz. Although some of these impairments can be overcome by oversizing the ground station antennas and high power amplifiers, the current trend is using small (less than 20 inches apertures), low-cost ground stations (less than $1000) that can be easily deployed at user premises. As a consequence, most Ka-band systems are expected to employ different forms of fade mitigation that can be implemented relatively easily and at modest cost. The rain fade mitigation approaches are defined by three types of Ka-band communications systems - a low service rate (less than 1.5 Mb/s), a moderate service rate (1.5 to 6 Mb/s) system and a high service rate (greater than 43 Mb/s) system. The ACTS VSAT network, which includes an adaptive rain fade technique, is an example of a moderate service rate.

  12. ATLAS computing operations within the GridKa Cloud

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, J; Walker, R [LMU Munich (Germany); Olszewski, A [Institute of Nuclear Physics Krakow (Poland); Nderitu, S [University of Bonn (Germany); Serfon, C; Duckeck, G

    2010-04-01

    The organisation and operations model of the ATLAS T1-T2 federation/Cloud associated to the GridKa T1 in Karlsruhe is described. Attention is paid to Cloud level services and the experience gained during the last years of operation. The ATLAS GridKa Cloud is large and divers spanning 5 countries, 2 ROC's and is currently comprised of 13 core sites. A well defined and tested operations model in such a Cloud is of the utmost importance. We have defined the core Cloud services required by the ATLAS experiment and ensured that they are performed in a managed and sustainable manner. Services such as Distributed Data Management involving data replication,deletion and consistency checks, Monte Carlo Production, software installation and data reprocessing are described in greater detail. In addition to providing these central services we have undertaken several Cloud level stress tests and developed monitoring tools to aid with Cloud diagnostics. Furthermore we have defined good channels of communication between ATLAS, the T1 and the T2's and have pro-active contributions from the T2 manpower. A brief introduction to the GridKa Cloud is provided followed by a more detailed discussion of the operations model and ATLAS services within the Cloud.

  13. Radiative neutron capture as a counting technique at pulsed spallation neutron sources: a review of current progress

    Science.gov (United States)

    Schooneveld, E. M.; Pietropaolo, A.; Andreani, C.; Perelli Cippo, E.; Rhodes, N. J.; Senesi, R.; Tardocchi, M.; Gorini, G.

    2016-09-01

    Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

  14. Fluorine-doped tin oxide films grown by pulsed direct current magnetron sputtering with an Sn target.

    Science.gov (United States)

    Liao, Bo-Huei; Kuo, Chien-Cheng; Chen, Pin-Jen; Lee, Cheng-Chung

    2011-03-20

    Fluorine-doped tin oxide (FTO) films have been deposited by pulsed DC magnetron sputtering with an Sn target. Various ratios of CF4/O2 gas were injected to enhance the optical and electrical properties of the films. The extinction coefficient was lower than 1.5×10(-3) in the range from 400 to 800 nm when the CF4O2 ratio was 0.375. The resistivity of fluorine-doped SnO2 films (1.63×10(-3) Ω cm) deposited at 300 °C was 27.9 times smaller than that of undoped SnO2 (4.55×10(-2) Ω cm). Finally, an FTO film was consecutively deposited for protecting the oxidation of indium tin oxide films. The resistivity of the double-layered film was 2.68×10(-4) Ω cm, which increased by less than 39% at a 450 °C annealing temperature for 1 h in air.

  15. Effects of nitrogen and pulsed mean welding current in AISI 316 austenitic stainless steel solidification cracks; Efecto del nitrogeno y la corriente media pulsada de soldadura en la formacion de grietas de solidificacion en aceros inoxidables AISI 316L

    Energy Technology Data Exchange (ETDEWEB)

    Trevisan, R. E.; Braga, E.; Fals, H. C.

    2002-07-01

    An analysis of the influence of nitrogen concentration in the weld zone and the pulsed mean welding current in the solidification crack formation is presented in this paper. The AISI 316L austenitic stainless steel was employed as the metal base. The welding was done using CC+ pulsed flux cored are welding process and AWS E316L wire type. The tests were conducted using CO{sub 2} shielding gas with four different nitrogen levels (0,5; 10 and 15%) in order to induce different nitrogen weld metal concentrations. The pulsed mean welding current was varied in three levels and the. Transvarestraint tangential strain test was fixed of 5%. The results showed that the solidification cracking decreased as the pulsed mean welding current increase. It was also verified that an increase of the weld zone nitrogen level was associated with a decrease in both the total length of solidification crack and the amount of {delta} ferrite. (AUthor) 20 refs.

  16. Development of a long pulse plasma gun discharge for magnetic turbulence studies

    Science.gov (United States)

    Schaffner, David

    2016-10-01

    A long pulse ( 300 μs) plasma gun discharge is in development at the Bryn Mawr College Plasma Laboratory for the production of sustained magnetized plasma injection for magnetohydrodynamic (MHD) turbulence studies. An array of eight 0.5mF parallel capacitors are used to create a pulse-forming-network (PFN) with a plateaued current output of 50kA for at least 200 of the 300 μs pulse. A 24cm inner diameter plasma gun provides stuffing flux fields at the stuffing threshold in order to allow for the continuous injection of magnetic helicity. Plasma is injected into a 24cm diameter flux-conserving aluminum chamber with a high density port array for fine spatial resolution diagnostic access. Fluctuations of magnetic field and saturation current are measured using pickup probes and Langmuir probes respectively.

  17. Analysis on background magnetic field to generate eddy current by pulsed gradient of permanent-magnet MRI

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper the analytical expressions for the magnetic field H and induction B in iron-pole plates generated by MRI gradient coil are given using line-current and the multilayer dielectric plate model with the mirror-image method.Eddy current emanates from the magnetic flux in the iron-pole plates.In order to fully suppress the eddy current,this magnetic flux should be fully eliminated.The research results indicate the magnetic permeability of the resist-eddy plate must be bigger than that of magnetic pole material,i.e.pure iron,and that the resist-eddy plate should be thick enough to be far away from its magnetic saturation.

  18. 基于脉冲涡流信号的金属膜厚测量%Thickness measurement of metallic coating from pulsed eddy-current signals

    Institute of Scientific and Technical Information of China (English)

    康学福; 陈立晶; 王奔; 尹武良

    2012-01-01

    As a new branch of the eddy current nondestructive testing, the pulsed eddy current testing technology can detect the thickness of the metal conductor quickly and easily. In order to study the technology in the measuring of the thickness of the metal, the sensor was designed firstly and its operating principal was analyzed. The ANSOFT software was used to get the response signal in different metal thickness. Different thickness of aluminum foils were detected and cubic spline interpolation was used to fit experimental data. The relationship between the thickness and voltage signals was obtained. The conclusion shows that the thickness of the metal can be detected precisely on the pulsed eddy current testing technology.%脉冲涡流检测技术能够快速方便地检测金属导体厚度,为了研究脉冲涡流检测技术在金属膜厚测量中的应用,首先设计了测量系统传感器,并分析了其工作原理;采用ANSOFT软件对不同测试金属厚度下传感器的响应信号进行了仿真计算;然后搭建了实际的测厚系统,对不同厚度的铝箔进行了检测,并对实验数据采用三次样条插值进行了拟合,得到了金属膜厚与电压信号的关系.研究结果表明:采用脉冲涡流技术能够较准确地测量出金属膜的厚度.

  19. Data of evolutionary structure change: 1KA4A-1WGZA [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available 1KA4A-1WGZA 1KA4 1WGZ A A EVFQNETIKQILAKYRRIWAIGHAQSVLGWDLEVNMPKE...confEVID> 0 1KA4 A 1KA4A...tryChain> 1KA4 A 1KA4A FPLGTRARLD... CA 334 SER CA 255 1KA4 A 1KA4A LEEGKVPREHP HH

  20. Advances in Ka-Band Communication System for CubeSats and SmallSats

    Science.gov (United States)

    Kegege, Obadiah; Wong, Yen F.; Altunc, Serhat

    2016-01-01

    A study was performed that evaluated the feasibility of Ka-band communication system to provide CubeSat/SmallSat high rate science data downlink with ground antennas ranging from the small portable 1.2m/2.4m to apertures 5.4M, 7.3M, 11M, and 18M, for Low Earth Orbit (LEO) to Lunar CubeSat missions. This study included link analysis to determine the data rate requirement, based on the current TRL of Ka-band flight hardware and ground support infrastructure. Recent advances in Ka-band transceivers and antennas, options of portable ground stations, and various coverage distances were included in the analysis. The link/coverage analysis results show that Cubesat/Smallsat missions communication requirements including frequencies and data rates can be met by utilizing Near Earth Network (NEN) Ka-band support with 2 W and high gain (>6 dBi) antennas.

  1. Produksi Functionally Graded Material (FGM dari Hydroxyapatite-Serat Sutra untuk Aplikasi di Bidang Biomaterial dengan Teknik Pulse Electric Current Sintering

    Directory of Open Access Journals (Sweden)

    Tjokorda Gde Tirta Nindhia

    2006-01-01

    Full Text Available This research is intended to produce functionally graded material (FGM of Hydroxyapatite (Hap-silk fibroin by pulse electric current sintering in facing the need in biomaterial application. The sample is created with 4 layers with the thickness for each layer is 0,625 mm, so that the total samples thickness become 2.5mm, with diameter 15 mm. The carbon die is used to compact the sample. The composition of lower layer is 100% silk fibroin, after that 90% silk fibroin +10% Hap, third layer was 80% silk fibroin + 20%Hap, and 70% silk fibroin +30% Hap for the upper layer. The properties of the FGM product was characterized by optical microscope and scanning electron microscope (SEM, three point bend with single-edge beam fracture toughness test (KIC. The grade of the FGM material is proven by using electron probe micro analyzer (EPMA. The value of fracture toughness is 0.45 MPa.m1/2. The sample still can support the load after maximum load is reached. Optical micrograph and SEM, and result from EPMA indicate that the Hap-silk fibroin FGM can be produce perfectly by using the method that is introduced in this research. Abstract in Bahasa Indonesia : Penelitian ini bertujuan memproduksi functionally graded material (FGM dari hydroxyapatite (Hap-serat sutra, melalui teknik pulse electric current sintering untuk memenuhi tantangan kebutuhan akan bahan jenis ini untuk digunakan dibidang biomaterial. Benda uji terdiri dari 4 lapis dengan ketebalan sama untuk tiap lapisnya sehingga tebal total menjadi 2.5 mm dengan diameter 15 mm. Komposisi lapisan paling bawah adalah 100% serat sutra, setelah itu 90% serat sutra + 10% Hap. Lapisan ketiga dengan komposisi 80% serat sutra + 20% Hap, dan 70% serat sutra + 30% Hap untuk lapisan paling atas. Perilaku produk FGM ini dikarakterisasikan dengan mikroskop optik, mikroskop electron, uji ketangguhan retak three point bend with single-edge. Gradasi (grade dari FGM dibuktikan dengan electron probe micro analyzer (EPMA

  2. Superhard carbon deposited by pulsed high-current arc as protective nanocoating for magnetic hard disks; Superharter Kohlenstoff abgeschieden mit gepulstem Hochstrombogen als Nanoschutzschicht fuer Magnetspeicherplatten

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaeuser, M.; Hilgers, H. [IBM Mainz (Germany). Abt. 4627; Witke, T. [Infenion Dresden (Germany). Bereich PVD; Siemroth, P. [Fraunhofer-Institut fuer Werkstoffphysik und Schichttechnologie (IWS), Dresden (Germany)

    2001-08-01

    Superhard amorphous carbon films (ta-C) deposited by pulsed high-current arc (HCA) possess a good perspective to be used as future ultrathin protective coatings for magnetic hard disks. The ta-C coatings meet all demands concerning the mechanical, chemical and tribological properties required for corrosion and wear protective coatings with thicknesses of 2-3 nm. From the current point of view the deposition technique also qualifies for an industrial mass production. Consequently there is a very good prospect that in near future the high-current arc technique will be the method of choice for carbon deposition in industrial hard disk drive production. (orig.) [German] Superharte amorphe Kohlenstoffschichten (ta-C), die mit gepulstem Hochstrombogen (high-current arc, HCA) abgeschieden werden, besitzen ein hohes Potential als zukuenftige ultraduenne Schutzschichten fuer Magnetspeicherplatten. Die ta-C-Schichten erfuellen alle wesentlichen Anforderungen, die in mechanischer, chemischer und tribologischer Hinsicht an 2-3 nm dicke Verschleiss- und Korrosionsschutzschichten gestellt werden. Auch die Beschichtungstechnik ist aus jetziger Sicht fuer die Massenproduktion geeignet. Damit bestehen sehr gute Aussichten, dass in naher Zukunft die Hochstrombogenverdampfung die Methode der Wahl fuer die Kohlenstoffabscheidung in der industriellen Festplattenproduktion darstellt. (orig.)

  3. Investigation of the Current Turn-off Characteristics of a GTO Thyristor in an Inductive Pulse Forming Network

    Science.gov (United States)

    2008-05-02

    pnp transistor (the top transistor in the figure) coupled to an npn transistor (the bottom transistor in the figure) such that the...collector of the pnp transistor connects to the base of the npn transistor and the collector of the npn transistor connects to the base of the pnp ... transistor . By design, a pnp P N P N N N N N N Cathode Anode Gate Base Unit Base Unit 12 transistor will conduct whenever current is

  4. Mechanisms of hardening, wear and corrosion improvement of 316 L stainless steel by low energy high current pulsed electron beam surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Zou, J.X. [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, UMR-CNRS 7078), Universite Paul Verlaine - Metz, Ile du Saulcy, 57045 Metz (France); Shanghai Engineering Research Center of Mg Materials and Applications and School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China); Zhang, K.M. [School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620 (China); Hao, S.Z.; Dong, C. [Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China); Grosdidier, T., E-mail: thierry.grosdidier@univ-metz.f [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, UMR-CNRS 7078), Universite Paul Verlaine - Metz, Ile du Saulcy, 57045 Metz (France); Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China)

    2010-12-01

    The mechanisms of corrosion and wear improvements by low energy high current pulsed electron beam (LEHCPEB) have been investigated for an AISI 316 L steel. Selective purification followed by epitaxial growth occurred in the top surface melted layer (2-3 {mu}m thick) that was softened by tensile stresses and, to a much lower extent, by lower efficiency of MnS precipitation hardening. Electrochemical impedance spectroscopy and potentiodynamic polarization analyses used to model the corrosion behavior revealed that, while craters initiated at MnS inclusions initially served as pitting sites, the resistance was increased by 3 orders of magnitude after sufficient number of pulses by the formation of a homogeneous covering layer. The wear resistance was effectively improved by sub-surface (over 100 {mu}m) work hardening associated with the combine effect of the quasi-static thermal stress and the thermal stress waves. The overall results demonstrate the potential of the LEHCPEB technique for improving concomitantly the corrosion and wear performances of metallic materials.

  5. [High current microsecond pulsed hollow cathode lamp excited ionic fluorescence spectrometry of alkaline earth elements in inductively coupled plasma with a Fassel-torch].

    Science.gov (United States)

    Zhang, Shao-Yu; Gong, Zhen-Bin; Huang, Ben-Li

    2006-02-01

    High current microsecond pulsed hollow cathode lamp (HCMP-HCL) excited ionic fluorescence spectrometry (IFS) of alkaline earth elements in inductively coupled plasma (ICP) with a Fassel-torch has been investigated. In wide condition ranges only IFS was observed, whilst atomic fluorescence spectrometry (AFS) was not detectable. More intense ionic fluorescence signal was observed at lower observation heights and at lower incident RF powers. Without introduction of any reduction organic gases into the ICP, the limit of detection (LOD, 3sigma) of Ba was improved by 50-fold over that of a conventional pulsed (CP) HCL with the Baird sleeve-extended torch. For Ca and Sr, the LODs by HCMP-HCL-ICP-IFS and CP-HCL-ICP-AFS show no significant difference. Relative standard deviations were 0.6%-1.4% (0.1-0.2 microg x mL(-1), n = 10) for 5 ionic fluorescence lines. Preliminary studies showed that the intensity of ionic fluorescence could be depressed in the presence of K, Al and P.

  6. Pra Na Wa Ka: The Development of Training Course for Continuing Buddhism

    Directory of Open Access Journals (Sweden)

    Phra M.P. Romphothanthong

    2012-01-01

    Full Text Available Problem statement: Buddhism is a religion that requires meditation, practice, intellectual precepts of the threefold-training such as morality, concentration and wisdom. The purpose of practicing Buddhism is the goal of deliverance through attaining knowledge and wisdom. The Pra Na Wa Ka are newly ordained monks and needed to study both of the scriptures and the practice for appreciating understanding in morality, concentration and wisdom. A training model and guidelines are needed to improve the quality and efficiency of Pra Na Wa Ka because currently most of the monks who are the teachers lacked knowledge and are not ready to act as the Pra Na Wa Ka teacher, because lack of the teaching media, lack of the proper knowledge of the teacher vocational, the lesson plan arrangement, the psychology of teaching, lack of technique variety of teaching methods. Most of the temple had no education administration of the Pra Na Wa Ka who ordained in short-term, within 3 days 7 days 15 days or to one month, lack of the short period course to study about Buddhism, the Pra Na Wa Ka cannot accurately recite the Pali words, the Pra Na Wa Ka who were ordained were not motivated and faithful in learning and low morality. Approach: This research intended to study the history of the education administration of the Pra Na Wa Ka (Newly ordained monk and to study about the problems and need of the Pra Na Wa Ka in knowledge about Buddhism and to develop the curriculum and the training package of the Pra Na Wa Ka in Buddhism. Results: The Pra Na Wa Ka traing course is a curriculum to study Buddhism through 3 training courses; (1 Basic Course: 3 days for initiation 7 days, (2 Intermediate course 7 days for initiation 15 days and (3 Long period course 15 days for initiation more than 30 days. The training courses were accompanied by a training kit to understand the main precepts of morality, concentration and wisdom. The curriculum was successful in providing Pra Na Wa Ka

  7. A compact, coaxial shunt current diagnostic for X pinches.

    Science.gov (United States)

    Wang, Liangping; Zhang, Jinhai; Li, Mo; Zhang, Xinjun; Zhao, Chen; Zhang, Shaoguo

    2015-08-01

    A compact coaxial shunt was applied in X-pinches experiments on Qiangguang pulsed power generator. The coaxial shunt was designed to have a compact construction for smaller inductance and more, for conveniently assembling upon the X pinch load structure. The coaxial shunt is also a cheap current probe and was easily built by research groups. The shunt can monitor a 100 kA high current with a 100 ns rise time. The calibration results showed that the probe used in the experiments has a resistance of 3.2 mΩ with an uncertainty of 3%, and its response time to the step signal is less than 7 ns.

  8. Stress controlled pulsed direct current co-sputtered Al1−xScxN as piezoelectric phase for micromechanical sensor applications

    Directory of Open Access Journals (Sweden)

    Simon Fichtner

    2015-11-01

    Full Text Available Scandium alloyed aluminum nitride (Al1−xScxN thin films were fabricated by reactive pulsed direct current co-sputtering of separate scandium and aluminum targets with x ≤ 0.37. A significant improvement of the clamped transversal piezoelectric response to strain e31,f from −1.28 C/m2 to −3.01 C/m2 was recorded, while dielectric constant and loss angle remain low. Further, the built-in stress level of Al1−xScxN was found to be tuneable by varying pressure, Ar/N2 ratio, and Sc content. The thus resulting enhancement of the expectable signal to noise ratio by a factor of 2.1 and the ability to control built-in stress make the integration of Al1−xScxN as the piezoelectric phase of micro-electro-mechanical system sensor applications highly attractive.

  9. The Relationship Between Multi-Frequency and Pulsed Eddy Current Testing Techniques%浅析多频涡流与脉冲涡流检测技术间的关系

    Institute of Scientific and Technical Information of China (English)

    林俊明

    2012-01-01

    对多频涡流与脉冲涡流两种不同的电磁无损检测技术的基本原理分别进行了介绍,进而从脉冲涡流的傅里叶展开式中分析了两者间的关系。指出脉冲涡流检测技术本质上等同于一种衰减型的多频涡流检测技术,而多频涡流可以认为是高频加权的脉冲涡流形式。对这两种涡流检测技术在实际生产中的应用进行了简单介绍。随着涡流检测理论的深入研究,电子技术与计算机技术的迅速发展,多频涡流和脉冲涡流检测技术将成为涡流检测的重要组成部分。%The basic principles of two different eddy current testing techniques, the multi-frequency eddy current and pulsed eddy current testing techniques, are introduced and the relationship between them is presented from the Fourier series of the pulsed input signal. It is indicated that the pulsed eddy current testing technique is equal an attenuation type of multi-frequency eddy current testing in nature. Whereas the multi-frequency eddy current testing could be regard as a high frequency weighted pulsed eddy current testing. Some industry applications of these two eddy current testing techniques are shown. With the developments of eddy current theories and the electronic and computer techniques, the multi-frequency eddy current and pulsed eddy current testing techniques will play more and more important roles in eddy current testing.

  10. CALCULATION-EXPERIMENTAL METHOD OF RESEARCH IN A METALLIC CONDUCTOR WITH THE PULSE CURRENT OF ELECTRONIC WAVEPACKAGES AND DE BROGLIE ELECTRONIC HALF-WAVES

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2016-12-01

    Full Text Available Purpose. Development of calculation-experimental method for a discovery and study of electronic wavepackages (EWP and of de Broglie electronic half-waves in a metallic conductor with the pulse axial-flow current of high density. Methodology. Theoretical bases of the electrical engineering, bases of quantum physics, electrophysics bases of technique of high voltage and large pulsecurrents, and also bases of technique of measuring of permanent and variable electric value. Results. On the basis of generalization of results of research of features of the longitudinal wave periodic distributing of negatively charged transmitters of electric current of conductivity in the thin round continuous zincked steel wire offered and approved in the conditions of high-voltage laboratory method for a discovery and direct determination in him of geometrical parameters of «hot» and «cold» longitudinal areas quantized periodic longitudinal EWP and accordingly the mediated determination of values of the quantized lengths formative their de Broglie electronic half-waves. It is shown that results of close quantum mechanical calculations of EWP and quantized lengths λenz/2 of longitudinal de Broglie half-waves for the probed wire long l0 well comport with the results of the executed high temperature experiments on the powerful high-voltage generator of homopolar large pulse current of millisecond duration. Originality. First calculation-experimental a way the important for the theory of electricity fact of existence is set in a round metallic explorer with the impulsive axial-flow current of the quantized coherent de Broglie electronic half-waves, amplitudes of which at the quantum number of n=1,3,9 correspond the middles of «hot» longitudinal areas of EWP. Calculation quantum mechanical correlation of type of λenz/2=l0/n got experimental confirmation, in obedience to which on length of l0 conductor the integer of quantized electronic half-waves is always laid

  11. Design of Weak Signal Conditioning Circuit for Pulsed Eddy Current%脉冲涡流检测微弱信号调理电路设计

    Institute of Scientific and Technical Information of China (English)

    孙思成; 付跃文

    2013-01-01

    分析了铁磁性材料脉冲涡流检测后期微弱信号的特点,在此基础上进行了脉冲涡流微弱信号调理电路的设计.设计采用了阻抗匹配、对称式限幅差分前置放大、浮空的电压源和屏蔽与接地技术,有效地提高了信号的共模抑制比和信号调理系统的信噪比.试验结果表明:设计的信号调理电路改善了接收系统的信噪比,提高了脉冲涡流晚期微弱信号的分辨能力(有效检测信号为几个微伏),提高了在复杂电磁环境下测量铁磁性材料厚度的检测灵敏度.%This paper analyzed the weak late stage signal of pulsed eddy current testing of the ferromagnetic materials briefly,and signal conditioning circuit was designed based on the analysis.Techniques of the impedance matching,electromagnetism shielding,grounding,floating empty DC voltage source and limited different preamplifying symmetrically are used and the SNR (Signal-to-Noise Rate) of signal conditioning system is improved effectively.The experiment results show that the design of weak signal conditioning circuit for pulsed eddy current improves the SNR and signal of several microvolts can be detected.Effective detection for the small corrosion of ferromagnetic materials in complicated electromagnetic environment is implemented.

  12. Simulation and experiment of pulsed eddy current array detection system%脉冲涡流阵列检测系统仿真与实验

    Institute of Scientific and Technical Information of China (English)

    李天博; 刘守华; 陈坤华

    2013-01-01

    Respecting to the shortcomings of the detection efficiency and accuracy existing in the traditional pulsed eddy current sensor, a new pulse array detection model with multiple coils was proposed. The new array detector model was simulated using electromagnetic field simulation software of ANSOFT, and an experimental test platform was set up to test the model. The result shows that the detection model has good response characteristics, with each coil work independently, responsing synchronously, making up for the shortcoming of rapid testing deficiency existed in the traditional pulsed eddy current instrument, and meeting the requirements of fast positioning and detecting the thickness of protective layer on a conductive substrate. As for a further comment, it has compact structure, and high controllability, suitable for rapid nondestructive testing on a large area of the target substrate.%针对传统脉冲涡流传感器在检测效率和精度上存在的不足,提出了一种由多个线圈组合而成的新型阵列脉冲检测模型。运用ANSOFT电磁场仿真软件对新型阵列检测模型进行了仿真分析,并搭建了实验平台进行测试。结果表明该检测模型具有良好的响应特性,每个线圈独立工作、同步响应,弥补了传统脉冲涡流仪器在快速检测时存在的不足,符合对导电基体进行快速定位和保护层厚度检测的要求,并且模型结构紧凑,可控性高,适合对大面积目标基体进行快速无损检测。

  13. A methodology to investigate the intrinsic effect of the pulsed electric current during the spark plasma sintering of electrically conductive powders.

    Science.gov (United States)

    Locci, Antonio Mario; Cincotti, Alberto; Todde, Sara; Orrù, Roberto; Cao, Giacomo

    2010-08-01

    A novel methodology is proposed for investigating the effect of the pulsed electric current during the spark plasma sintering (SPS) of electrically conductive powders without potential misinterpretation of experimental results. First, ensemble configurations (geometry, size and material of the powder sample, die, plunger and spacers) are identified where the electric current is forced to flow only through either the sample or the die, so that the sample is heated either through the Joule effect or by thermal conduction, respectively. These ensemble configurations are selected using a recently proposed mathematical model of an SPS apparatus, which, once suitably modified, makes it possible to carry out detailed electrical and thermal analysis. Next, SPS experiments are conducted using the ensemble configurations theoretically identified. Using aluminum powders as a case study, we find that the temporal profiles of sample shrinkage, which indicate densification behavior, as well as the final density of the sample are clearly different when the electric current flows only through the sample or through the die containing it, whereas the temperature cycle and mechanical load are the same in both cases.

  14. A methodology to investigate the intrinsic effect of the pulsed electric current during the spark plasma sintering of electrically conductive powders

    Directory of Open Access Journals (Sweden)

    Antonio Mario Locci, Alberto Cincotti, Sara Todde, Roberto Orrù and Giacomo Cao

    2010-01-01

    Full Text Available A novel methodology is proposed for investigating the effect of the pulsed electric current during the spark plasma sintering (SPS of electrically conductive powders without potential misinterpretation of experimental results. First, ensemble configurations (geometry, size and material of the powder sample, die, plunger and spacers are identified where the electric current is forced to flow only through either the sample or the die, so that the sample is heated either through the Joule effect or by thermal conduction, respectively. These ensemble configurations are selected using a recently proposed mathematical model of an SPS apparatus, which, once suitably modified, makes it possible to carry out detailed electrical and thermal analysis. Next, SPS experiments are conducted using the ensemble configurations theoretically identified. Using aluminum powders as a case study, we find that the temporal profiles of sample shrinkage, which indicate densification behavior, as well as the final density of the sample are clearly different when the electric current flows only through the sample or through the die containing it, whereas the temperature cycle and mechanical load are the same in both cases.

  15. Numerical simulation of thermal-mechanical process of Al-Si-Pb alloy treated by high current pulsed electron beam

    Institute of Scientific and Technical Information of China (English)

    L(U) Xiao-xia; LI Rong-guang; AN Jian

    2006-01-01

    The modified microstructure of Al-Si-Pb alloys irradiated by high current electron beam (HCPEB) reveals three distinct regions: a molten zone, an overlapped zone of heat-affected and quasistatic thermal stress-affected zone, and a transition zone followed by the substrate. The hardness and wear properties of the alloys were significantly improved. To better understand these changes in microstructure and properties, the physical model for the simulation of temperature and quasistatic stress fields was established. Based on experimental investigation and physical models, the temperature field and stress field were simulated for Al-Si-Pb alloy. The starting melting position, largest crater depth, melting layer thickness, and quasistatic stress distribution were obtained. These results reveal the mechanism of crater formation on the surface and improvement of hardness and wear resistance.

  16. The Mars Global Surveyor Ka-Band Link Experiment (MGS/KaBLE-II)

    Science.gov (United States)

    Morabito, D.; Butman, S.; Shambayati, S.

    1999-01-01

    The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4-GHz) downlink. The signals are simultaneously transmitted from a 1.5-m-diameter parabolic antenna on MGS and received by a beam-waveguide (BWG) research and development (R&D) 34-meter a ntenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. This Ka-band link experiment (KaBLE-II) allows the performances of the Ka-band and X-band signals to be compared under nearly identical conditions. The two signals have been regularly tracked during the past 2 years. This article presents carrier-signal-level data (P_c/N_o) for both X-band and Ka-band acquired over a wide range of station elevation angles, weather conditions, and solar elongation angles. The cruise phase of the mission covered the period from launch (November 7, 1996) to Mars orbit capture (September 12, 1997). Since September 12, 1997, MGS has been in orbit around Mars. The measurements confirm that Ka-band could increase data capacity by at least a factor of three (5 dB) as compared with X-band. During May 1998, the solar corona experiment, in which the effects of solar plasma on the X-band and Ka-band links were studied, was conducted. In addition, frequency and difference frequency (f_x - f_(Ka)/3.8), ranging, and telemetry data results are presented. MGS/KaBLE-II measured signal strengths (for 54 percent of the experiments conducted) that were in reasonable agreement with predicted values based on preflight knowledge, and frequency residuals that agreed between bands and whose statistics were consistent with expected noise sources. For passes in which measured signal strengths disagreed with predicted values, the problems were traced to known deficiencies, for example, equipment operating under certain conditions, such as a cold Ka-band solid-state power amplifier (SSPA

  17. Pulse transformer for the AA lithium lens

    CERN Multimedia

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  18. Development of a 1 kA, 50 Hz Superconducting Converter

    NARCIS (Netherlands)

    Chevtchenko, O.A.; ten Kate, Herman H.J.; Krooshoop, Hendrikus J.G.; Fedorovsky, Michael A.

    1995-01-01

    A single-phase, thermally switched superconducting power converter operating at mains frequency is being developed and tested by the authors. Typical design values of the device are: input voltage of 220 V; input current of 7 A; output voltage of 1 V; and output current of 1 kA. The average output

  19. Modulation transfer functions at Ka band

    Science.gov (United States)

    Hesany, Vahid; Sistani, Bita; Salam, Asif; Haimov, Samuel; Gogineni, Prasad; Moore, Richard K.

    The modulation transfer function (MTF) is often used to describe the modulation of the radar signal by the long waves. MTFs were measured at 35 GHz (Ka band) with a switched-beam vector slope gauge/scatterometer on the research platform NORDSEE as part of the SAXON-FPN experiment. Three independent measurements of the scattering were available for each height measurement. This provided the opportunity to average the time series to reduce the effects of fading noise and sea spikes, or, alternatively, to append the time series to achieve more degrees of freedom in the spectral estimates. For upwind measurements, the phase of the VV-polarized Ka-band MTF was always positive, which implies that the maximum of the radar return originates from the forward face of the long-scale waves. This phase increases with increasing wind speed. The magnitude of the MTF decreases with increasing wind speed.

  20. Stability measurements on the 50 kA SMES conductor

    Science.gov (United States)

    Pfotenhauer, M. J.

    Stability measurements have been made on a large aluminium stabilized conductor designed for use in a superconducting magnetic energy storage (SMES) coil. The conductor has been built to carry 50 kA at 1.8 K and in 4.6 T field. It consists of a 25.4 mm diameter, high purity aluminium stabilizer with eight superconducting strands of 2.8 mm diameter each, composed of 60% Cu, 40% NbTi. The strands are set in eight helical grooves, evenly spaced around the outer diameter of the aluminium. The conductor is designed for use in full scale SMES units and has been tested in the 1 m diameter, three-turn test coil of the University of Wisconsin proof of principle experiment (POPE). The POPE facility includes the test coil, a 4 T background magnet, a dewar for a 1.8 K, 1 atm environment and a 100 kA d.c. power supply. Test results demonstrate good agreement with a new dynamic stability model. The balance of time-dependent heat generation during current diffusion and time-dependent cooling to the helium produces three new features of stability: 1, a threshold current for propagation; 2, large propagation velocities; and 3, a finite length travelling normal zone. POPE measurements verify all three features of the dynamic stability model.

  1. 脉冲涡流圆柱型探头参数的优化设计%Optimization Design of Pulsed Eddy Current Circular Probe

    Institute of Scientific and Technical Information of China (English)

    周德强; 张斌强; 王海涛; 尤丽华; 盛卫峰

    2012-01-01

    The paper introduced the theory of pulsed eddy current(PEC) testing. Based on Finite Element Method software, the distribution of magnetism and eddy current was presented for PEC circular probe. The results showed that the eddy current of flat excited coils could be effective to penetrate inside the metal sample, and it could improve the sensitivity of the testing system of PEC testing. Through the analysis of the eddy current density and the penetrating depth for the different excited frequency, the best excited frequency could be concluded. It will provide the guide of PEC probe design.%介绍了脉冲涡流检测的工作原理。通过有限元对圆柱型探头不同参数的线圈周围磁场和被检试件中感生涡流的分布进行了仿真,得出了扁平型的激励线圈产生的磁通量能够有效地渗透到被检试件的内部,有利于系统检测灵敏度的提高。通过不同激励频率在试件中的涡流密度、渗透深度的分析,能够根据脉冲涡流检测对象,得到探头中所用的最佳工作频率,为脉冲涡流探头的实际检测奠定基础。

  2. ITER1O kA高温超导电流引线测试装置低温系统的研究%Cryogenic System Development for Test Facility of 10 kA High-Temperature-Superconductor Current Lead in International Thermonuclear Experimental Reactor

    Institute of Scientific and Technical Information of China (English)

    倪清; 毕延芳; 丁开忠; 冯汉升; 周挺志; 沈光; 刘承连; 黄雄一; 宋云涛

    2011-01-01

    The cryogenic system,dedicated to the testing facility of the 10 Ka high-temperature-superconductor current lead (HTS-CL) in international thermonuclear experimental reactor,has been successfully developed. The cryogenic system includes a 500W/4.5K helium refrigerator, a vacuum dewar, cryogenic modules (cryogenic control valves, sub-cooler, electrical heaters, and thermal shields) ,carburetors,a set of cryogenic pipelines,and control unit. The discussions focused on the technical requirements and the design considerations: such as the design of vacuum Dewar and the sub-cooler, and the scheme of the cooling circuit. The field-test results of the newly-developed cryogenic system show that it is capable of doing a good job.%为ITER CC 10 kA高温超导电流引线服务的低温性能测试装置已研制完成,并成功运行.其低温系统主要由500W/4.5 K氦制冷机,真空杜瓦,低温组件(低温阀门,过冷槽,管道加热器,热防护层),汽化器及低温传输管线等部分组成.本文对真空杜瓦和过冷槽进行设计,并讨论该低温系统的冷却流程方案,最后通过电流引线10 kA稳态实验结果对低温系统的运行效果进行分析,结果表明该低温系统运行稳定,能满足ITER CC电流引线的测试需要.

  3. KaKa带你杀大网

    Institute of Scientific and Technical Information of China (English)

    昊月

    2005-01-01

    上期和大家一起漫步dust2,体会了其中的妙处,这期KaKa带你去inferno这张地图探个究竟。inferno是一张对于警匪都比较平衡的地图,攻守都有各自的优势,如何利用这些优势让自己在大网里的杀人数剧增,是KaKa这期要告诉大家的重点。上次KaKa教大家如果做匪徒在大网里杀人,这次咱做警察,练练如何在大网里防守,这次我们进一个开局金钱数16000的大网里,免得初期还要手枪肉搏。一切准备就绪,开局买上M4,炸宙,闪光再带把拆包器,可能会有人有疑问。”又不是打比赛,要买拆包器干吗?杀光敌人不就得了吗。”KaKa在这里还要提醒你一点.1.5版和1.6版其中的一个小区别就是如果警察成功拆除炸弹的话,可以增加3个杀人数,所以只要有机会就奋不顾身去抢拆包,这也算是提高自己在大网里杀人数一个“歪门邪道”,可比你和3个匪徒周旋半天划得来哦。

  4. 脉冲涡流无损检测提离效应研究%Study of Lift - Off Effects for Pulsed Eddy Current Nondestructive Testing Technique

    Institute of Scientific and Technical Information of China (English)

    曹海霞; 王畅; 杨宾峰; 张军潮; 张辉

    2011-01-01

    In the course of pulsed eddy current testing, the incline of the probe or the roughness of the surface of the tested object will lead to the lift - off effects, which have a bad influence on the result of pulsed eddy current (PEC) nondestructive testing.Based on the analysis of the operating principle of PEC, two different simulation models with the excitation coils of columniform and rectangle structures are established by ANSYS finite element simulation software and the simulations on the specimen of ferromagnetic and non -ferromagnetic materials are done respectively.Through the analysis of the eddy current and rotated magnetic field, the influence effect of response signal with the variation of the lift - off distance and the reason is given.Finally, the results of simulation are verified by experiment methods.The results of the experimental work confirm the correctness of simulation, which will lay the foundation for the elimination of lift - off effects.%在脉冲涡流检测过程中,由于探头倾斜或被测对象表面不光滑会产生提离效应,提离效应严重影响着脉冲涡流无损检测的结果.本文在分析脉冲涡流检测技术工作原理的基础上,采用ANSYS有限元仿真软件建立了激励线圈为圆柱形和矩形两种结构的模型,并分别针对有裂纹缺陷的铁磁性(钢)和非铁磁性(铝)试件进行了仿真研究,通过分析试件中感应涡流和扰动磁场的变化,给出了不同情况下检测信号随提离变化的规律,并从原理上给出了解释.最后,通过实验的方法对仿真结果进行了验证,实验结果表明了仿真结果的正确性,从而为进一步的消除提离效应提供了有价值的参考依据.

  5. Isothermal oxidation behaviour of thermal barrier coatings with CoCrAlY bond coat irradiated by high-current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Jie [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Guan, Qingfeng, E-mail: guanqf@mail.ujs.edu.cn [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Hou, Xiuli [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Wang, Zhiping; Su, Jingxin; Han, Zhiyong [College of Science, Civil Aviation University of China, Tianjin 300300 (China)

    2014-10-30

    Highlights: • The original coarse surface was re-melted by pulsed electron beam irradiation. • Very fine grains were homogeneously dispersed on the irradiated coat surface. • A compact Al{sub 2}O{sub 3} scale was formed in irradiated TBCs at the onset of oxidation. • The selective oxidation of Al element avoided the formation of other oxides. • The irradiated coating has a much higher oxidation resistance. - Abstract: Thermal sprayed CoCrAlY bond coat irradiated by high-current pulsed electron beam (HCPEB) and thermal barrier coatings (TBCs) prepared with the irradiated bond coat and the ceramic top coat were investigated. The high temperature oxidation resistance of these specimens was tested at 1050 °C in air. Microstructure observations revealed that the original coarse surface of the as-sprayed bond coat was significantly changed as the interconnected bulged nodules with a compact appearance after HCPEB irradiation. Abundant Y-rich alumina particulates and very fine grains were dispersed on the irradiated surface. After high temperature oxidation test, the thermally grown oxide (TGO) in the initial TBCs grew rapidly and was comprised of two distinct layers: a large percentage of mixed oxides in the outer layer and a relatively small portion of Al{sub 2}O{sub 3} in the inner layer. Severe local internal oxidation and extensive cracks in the TGO layer were discovered as well. Comparatively, the irradiated TBCs exhibited thinner TGO layer, slower TGO growth rate, and homogeneous TGO composition (primarily consisting of Al{sub 2}O{sub 3}). The results indicate that TBCs with the irradiated bond coat have a much higher oxidation resistance.

  6. Testifying experiment of the multi-pulse phenomena of capillary discharge soft-X-ray laser

    Institute of Scientific and Technical Information of China (English)

    Bohan Luan; Yongpeng Zhao; Qi Wang; Yuanli Cheng; Yao Xie

    2008-01-01

    In a capillary discharge experiment for the neon-like argon lasing, we have proposed an experimental scheme to verify that the multi-spike of X-ray diode (XRD) signal is a multi-pulse laser or is a reflection of the laser pulse in the XRD.The ceramic capillary has an inner diameter of 3mm and a length of 200mm.At the gas pressure of 28Pa and discharge current of 27kA, stable lasing has been realized.The experimental results prove that the multi-spike of XRD signal is a reflection of the electromagnetic signal produced by the laser pulse in the XRD.The improved electrocircuit scheme of the XRD to minimize the reflection phenomena is also found.

  7. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Science.gov (United States)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  8. Optimization of Fusion Zone Grain Size, Hardness, and Ultimate Tensile Strength of Pulsed Current Microplasma Arc Welded AISI 304L Sheets Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Siva Prasad Kondapalli

    2014-01-01

    Full Text Available Austenitic stainless steel sheets have gathered wide acceptance in the fabrication of components, which require high temperature resistance and corrosion resistance, such as metal bellows used in expansion joints in aircraft, aerospace, and petroleum industry. In case of single pass welding of thinner sections of this alloy, Pulsed Current Microplasma Arc Welding (PCMPAW was found beneficial due to its advantages over the conventional continuous current process. The quality of welded joint depends on the grain size, hardness, and ultimate tensile strength, which have to be properly controlled and optimized to ensure better economy and desirable mechanical characteristics of the weld. This paper highlights the development of empirical mathematical equations using multiple regression analysis, correlating various process parameters to grain size, and ultimate tensile strength in PCMPAW of AISI 304L sheets. The experiments were conducted based on a five-factor, five-level central composite rotatable design matrix. A genetic algorithm (GA was developed to optimize the process parameters for achieving the desired grain size, hardness, and ultimate tensile strength.

  9. 35 Volt, 180 Ampere Pulse Generator with Droop Control for Pulsing Xenon Arcs

    DEFF Research Database (Denmark)

    Hviid, T.; Nielsen, S. O.

    1972-01-01

    The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light.......The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light....

  10. Analysis and Simulation of Minor Hysteresis Characteristic for Ferromagnetic Material Under Pulsed Current Excitation Considering Frequency and Pulsed Width%计及频率和脉宽脉冲电流激励下铁磁材料局部磁滞特性的分析与模拟

    Institute of Scientific and Technical Information of China (English)

    辛伟

    2015-01-01

    Excitation frequency and pulsed width were two important factors in the study of the minor hysteresis characteristics of ferromagnetic materials under pulsed current excitation. With pulsed current peak remaining unchanged, different minor hysteresis curves were obtained through changing frequency and pulsed width. The higher frequency is and the narrower pulsed width is, the more pulsed numbers of excitation current were needed to stabilize minor hysteresis curves. This phenomenon was caused by the magnetic aftereffect of magnetic flux density. To describe the impact of frequency and pulsed width on the minor hysteresis characteristics, the curve fitting method was used to establish mathematic relation between fitting functions of different minor hysteresis curves according to the change law of frequency, pulsed width and the magnetic flux density turning points values. Compared with experimental results, in a certain range, the simulation results prove that the mathematic expression can effectively reflect the influence law of frequency and pulsed width, and accurately simulate the minor hysteresis characteristics of ferromagnetic material when frequency and pulsed width of pulsed current are varied.%激励频率和脉宽是研究脉冲电流激励下铁磁材料局部磁滞特性的两个重要因素。脉冲电流峰值保持不变,改变频率和脉宽,得到不同的局部磁滞曲线。由于磁通密度具有磁后效应,频率越高,脉宽越小,磁后效应越明显,局部磁滞曲线达到稳定所需要的激励电流脉冲数越多。为描述频率和脉宽对铁磁材料局部磁滞特性的影响,根据频率、脉宽和转折点磁通密度值的变化规律,采用曲线拟合的方法建立不同局部磁滞曲线拟合函数间的数学关系。模拟结果和实验结果表明,在一定范围内,拟合的数学式能够有效地反映频率和脉宽的影响规律,较准确地模拟频率和脉宽不同的脉冲电流激

  11. Photoelectrocatalytic decomposition of ethylene using TiO{sub 2}/activated carbon fiber electrode with applied pulsed direct current square-wave potential

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Sheng-ying, E-mail: yesy@scau.edu.cn; Zheng, Sen-hong; Song, Xian-liang; Luo, Shu-can

    2015-06-30

    Highlights: • Ethylene was decomposed by a photoelectrocatalytic (PEC) process. • A pulsed direct current square-wave (PDCSW) potential was applied to the PEC cell. • An electrode of TiO{sub 2} or modified TiO{sub 2} and activated carbon fiber (ACF) was used. • TiO{sub 2}/ACF photocatalyst electrodes were modified by gamma radiolysis. • Efficiencies of the PEC process were higher than those of the process using DC. - Abstract: Removing ethylene (C{sub 2}H{sub 4}) from the atmosphere of storage facilities for fruits and vegetable is one of the main challenges in their postharvest handling for maximizing their freshness, quality, and shelf life. In this study, we investigated the photoelectrocatalytic (PEC) degradation of ethylene gas by applying a pulsed direct current DC square-wave (PDCSW) potential and by using a Nafion-based PEC cell. The cell utilized a titanium dioxide (TiO{sub 2}) photocatalyst or γ-irradiated TiO{sub 2} (TiO{sub 2}{sup *}) loaded on activated carbon fiber (ACF) as a photoelectrode. The apparent rate constant of a pseudo-first-order reaction (K) was used to describe the PEC degradation of ethylene. Parameters of the potential applied to the PEC cell in a reactor that affect the degradation efficiency in terms of the K value were studied. These parameters were frequency, duty cycle, and voltage. Ethylene degradation by application of a constant PDCSW potential to the PEC electrode of either TiO{sub 2}/ACF cell or TiO{sub 2}{sup *}/ACF cell enhanced the efficiency of photocatalytic degradation and PEC degradation. Gamma irradiation of TiO{sub 2} in the electrode and the applied PDCSW potential synergistically increased the K value. Independent variables (frequency, duty cycle, and voltage) of the PEC cell fabricated from TiO{sub 2} subjected 20 kGy γ radiation were optimized to maximize the K value by using response surface methodology with quadratic rotation–orthogonal composite experimental design. Optimized conditions were as

  12. Ferromagnetic Tubes Testing Based Pulsed Remote Field Eddy Current Technique%基于脉冲远场涡流的管道内检测技术

    Institute of Scientific and Technical Information of China (English)

    杨理践; 王赓; 高松巍

    2012-01-01

    针对传统远场涡流检测方法对铁磁性管道内外壁缺陷灵敏度相同,无法有效区分缺陷在管道内壁还是管道外表面的问题,提出了采用具有丰富频率成分的脉冲激励信号取代传统的远场涡流中正弦信号激励的方法.采用小波去噪方法滤除检测数据中的信号噪声;研究了将检测线圈分别置于近场区、过渡区和远场区时的信号时域特性与管壁伤的关系;进行了针对管道管壁内外相同宽度不同深度缺陷的检测试验,结果表明采用脉冲激励作为激励源并综合运用过渡区的检测信号的幅值和过零时间特征能够有效地区分管壁内外全周向的缺陷.%In view of the traditional remote field eddy current technique for ferromagnetic tube having the same sensitivity of inner and outside walls defect,unable to distinguish the defects in the inner wall or in the outer surface,this paper adopt with abundant frequency components of the pulse signal to replace the traditional remote field eddy current sinusoidal excitation signal. Using the methods of wavelet denoising to filter acquired signal and process the data. This paper studied the relationship between the tube wall defects and signal time-domain characteristics when the detector coil was placed in the direct zone, transition zone and remote field zone. Conduct experiments to acquire data about different depth defects in the inside or outside of the walls, the results show that using the pulse signal as excitation source and characteristics about the detect signal amplitude and zero-crossing time can effectively distinguish between the inner and outer circumferential direction tube wall defects.

  13. A Fast Pulsed Neutron Source for Time-of-Flight Detection of Nuclear Materials and Explosives

    Science.gov (United States)

    Krishnan, Mahadevan; Bures, Brian; James, Colt; Madden, Robert; Hennig, Wolfgang; Breus, Dimitry; Asztalos, Stephen; Sabourov, Konstantin; Lane, Stephen

    2011-12-01

    AASC has built a fast pulsed neutron source based on the Dense Plasma Focus (DPF). The more current version stores only 100 J but fires at ˜10-50 Hz and emits ˜106n/pulse at a peak current of 100 kA. Both sources emit 2.45±0.1 MeV (DD) neutron pulses of ˜25-40 ns width. Such fast, quasi-monoenergetic pulses allow time-of-flight detection of characteristic emissions from nuclear materials or high explosives. A test is described in which iron targets were placed at different distances from the point neutron source. Detectors such as Stilbene and LaBr3 were used to capture inelastically induced, 847 keV gammas from the iron target. Shielding of the source and detectors eliminated most (but not all) of the source neutrons from the detectors. Gated detection, pulse shape analysis and time-of-flight discrimination enable separation of gamma and neutron signatures and localization of the target. A Monte Carlo simulation allows evaluation of the potential of such a fast pulsed source for a field-portable detection system. The high rep-rate source occupies two 200 liter drums and uses a cooled DPF Head that is <500 cm3 in volume.

  14. A Fast Pulsed Neutron Source for Time-of-Flight Detection of Nuclear Materials and Explosives

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, Mahadevan; Bures, Brian; James, Colt; Madden, Robert [Alameda Applied Sciences Corporation, 3077 Teagarden Street, San Leandro, CA 94577 (United States); Hennig, Wolfgang; Breus, Dimitry; Asztalos, Stephen; Sabourov, Konstantin [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Lane, Stephen [NSF Center for Biophotonics and School of Medicine, University of California Davis, Sacramento CA, 95817 (United States)

    2011-12-13

    AASC has built a fast pulsed neutron source based on the Dense Plasma Focus (DPF). The more current version stores only 100 J but fires at {approx}10-50 Hz and emits {approx}10{sup 6}n/pulse at a peak current of 100 kA. Both sources emit 2.45{+-}0.1 MeV(DD) neutron pulses of {approx}25-40 ns width. Such fast, quasi-monoenergetic pulses allow time-of-flight detection of characteristic emissions from nuclear materials or high explosives. A test is described in which iron targets were placed at different distances from the point neutron source. Detectors such as Stilbene and LaBr3 were used to capture inelastically induced, 847 keV gammas from the iron target. Shielding of the source and detectors eliminated most (but not all) of the source neutrons from the detectors. Gated detection, pulse shape analysis and time-of-flight discrimination enable separation of gamma and neutron signatures and localization of the target. A Monte Carlo simulation allows evaluation of the potential of such a fast pulsed source for a field-portable detection system. The high rep-rate source occupies two 200 liter drums and uses a cooled DPF Head that is <500 cm{sup 3} in volume.

  15. A pulse-compression-ring circuit for high-efficiency electric propulsion.

    Science.gov (United States)

    Owens, Thomas L

    2008-03-01

    A highly efficient, highly reliable pulsed-power system has been developed for use in high power, repetitively pulsed inductive plasma thrusters. The pulsed inductive thruster ejects plasma propellant at a high velocity using a Lorentz force developed through inductive coupling to the plasma. Having greatly increased propellant-utilization efficiency compared to chemical rockets, this type of electric propulsion system may one day propel spacecraft on long-duration deep-space missions. High system reliability and electrical efficiency are extremely important for these extended missions. In the prototype pulsed-power system described here, exceptional reliability is achieved using a pulse-compression circuit driven by both active solid-state switching and passive magnetic switching. High efficiency is achieved using a novel ring architecture that recovers unused energy in a pulse-compression system with minimal circuit loss after each impulse. As an added benefit, voltage reversal is eliminated in the ring topology, resulting in long lifetimes for energy-storage capacitors. System tests were performed using an adjustable inductive load at a voltage level of 3.3 kV, a peak current of 20 kA, and a current switching rate of 15 kA/micros.

  16. Validation of GPM Ka-Radar Algorithm Using a Ground-based Ka-Radar System

    Science.gov (United States)

    Nakamura, Kenji; Kaneko, Yuki; Nakagawa, Katsuhiro; Furukawa, Kinji; Suzuki, Kenji

    2016-04-01

    GPM led by the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration of US (NASA) aims to observe global precipitation. The core satellite is equipped with a microwave radiometer (GMI) and a dual-frequency radar (DPR) which is the first spaceborne Ku/Ka-band dual-wavelength radar dedicated for precipitation measurement. In the DPR algorithm, measured radar reflectivity is converted to effective radar reflectivity by estimating the rain attenuation. Here, the scattering/attenuation characteristics of Ka-band radiowaves are crucial, particularly for wet snow. A melting layer observation using a dual Ka-band radar system developed by JAXA was conducted along the slope of Mt. Zao in Yamagata Prefecture, Japan. The dual Ka-band radar system consists of two nearly identical Ka-band FM-CW radars, and the precipitation systems between two radars were observed in opposite directions. From this experiment, equivalent radar reflectivity (Ze) and specific attenuation (k) were obtained. The experiments were conducted for two winter seasons. During the data analyses, it was found that k estimate easily fluctuates because the estimate is based on double difference calculation. With much temporal and spatial averaging, k-Ze relationship was obtained for melting layers. One of the results is that the height of the peak of k seems slightly higher than that of Ze. The results are compared with in-situ precipitation particle measurements.

  17. Ka-band Technologies for Small Spacecraft Communications via Relays and Direct Data Downlink

    Science.gov (United States)

    Budinger, James M.; Niederhaus, Charles; Reinhart, Richard; Downey, Joe; Roberts, Anthony

    2016-01-01

    As the scientific capabilities and number of small spacecraft missions in the near Earth region increase, standard yet configurable user spacecraft terminals operating in Ka-band are needed to lower mission cost and risk and enable significantly higher data return than current UHF or S-band terminals. These compact Ka-band terminals are intended to operate with both the current and next generation of Ka-band relay satellites and via direct data communications with near Earth tracking terminals. This presentation provides an overview of emerging NASA-sponsored and commercially provided technologies in software defined radios (SDRs), transceivers, and electronically steered antennas that will enable data rates from hundreds of kbps to over 1 Gbps and operate in multiple frequency bands (such as S- and X-bands) and expand the use of NASA's common Ka-bands frequencies: 22.55-23.15 GHz for forward data or uplink; and 25.5-27.0 GHz for return data or downlink. Reductions in mass, power and volume come from integration of multiple radio functions, operations in Ka-band, high efficiency amplifiers and receivers, and compact, flat and vibration free electronically steered narrow beam antennas for up to + 60 degrees field of regard. The software defined near Earth space transceiver (SD-NEST) described in the presentation is intended to be compliant with NASA's space telecommunications radio system (STRS) standard for communications waveforms and hardware interoperability.

  18. Non-inductive current probe

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl

    1977-01-01

    The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is......The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is...

  19. Comparative Study on the Grain Refinement of Al-Si Alloy Solidified under the Impact of Pulsed Electric Current and Travelling Magnetic Field

    Directory of Open Access Journals (Sweden)

    Yunhu Zhang

    2016-07-01

    Full Text Available It is high of commercial importance to generate the grain refinement in alloys during solidification by means of electromagnetic fields. Two typical patterns of electromagnetic fields, pulsed electric currents (ECP and traveling magnetic field (TMF, are frequently employed to produce the finer equiaxed grains in solidifying alloys. Various mechanisms were proposed to understand the grain refinement in alloys caused by ECP and TMF. In this paper, a comparative study is carried out in the same solidification regime to investigate the grain refinement of Al-7 wt. %Si alloy driven by ECP and TMF. Experimental results show that the application of ECP or TMF can cause the same grain refinement occurrence period, during which the refinement of primary Al continuously occurs. In addition, the related grain refinement mechanisms are reviewed and discussed, which shows the most likely one caused by ECP and TMF is the promoted dendrite fragmentation as the result of the ECP-induced or TMF-induced forced flow. It suggests that the same grain refinement process in alloys is provoked when ECP and TMF are applied in the same solidification regime, respectively.

  20. Stress controlled pulsed direct current co-sputtered Al{sub 1−x}Sc{sub x}N as piezoelectric phase for micromechanical sensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Fichtner, Simon, E-mail: sif@tf.uni-kiel.de [Institute of Material Science, Christian-Albrechts-Universität, Kaiserstr. 2, 24143 Kiel (Germany); Reimer, Tim; Chemnitz, Steffen; Wagner, Bernhard [Institute of Material Science, Christian-Albrechts-Universität, Kaiserstr. 2, 24143 Kiel (Germany); Fraunhofer Institute for Silicon Technology, Fraunhoferstr. 1, 25524 Itzehoe (Germany); Lofink, Fabian [Fraunhofer Institute for Silicon Technology, Fraunhoferstr. 1, 25524 Itzehoe (Germany)

    2015-11-01

    Scandium alloyed aluminum nitride (Al{sub 1−x}Sc{sub x}N) thin films were fabricated by reactive pulsed direct current co-sputtering of separate scandium and aluminum targets with x ≤ 0.37. A significant improvement of the clamped transversal piezoelectric response to strain e{sub 31,f} from −1.28 C/m{sup 2} to −3.01 C/m{sup 2} was recorded, while dielectric constant and loss angle remain low. Further, the built-in stress level of Al{sub 1−x}Sc{sub x}N was found to be tuneable by varying pressure, Ar/N{sub 2} ratio, and Sc content. The thus resulting enhancement of the expectable signal to noise ratio by a factor of 2.1 and the ability to control built-in stress make the integration of Al{sub 1−x}Sc{sub x}N as the piezoelectric phase of micro-electro-mechanical system sensor applications highly attractive.