WorldWideScience

Sample records for k-internal conversion coefficients

  1. Analysis of internal conversion coefficients

    International Nuclear Information System (INIS)

    Coursol, N.; Gorozhankin, V.M.; Yakushev, E.A.; Briancon, C.; Vylov, Ts.

    2000-01-01

    An extensive database has been assembled that contains the three most widely used sets of calculated internal conversion coefficients (ICC): [Hager R.S., Seltzer E.C., 1968. Internal conversion tables. K-, L-, M-shell Conversion coefficients for Z=30 to Z=103, Nucl. Data Tables A4, 1-237; Band I.M., Trzhaskovskaya M.B., 1978. Tables of gamma-ray internal conversion coefficients for the K-, L- and M-shells, 10≤Z≤104, Special Report of Leningrad Nuclear Physics Institute; Roesel F., Fries H.M., Alder K., Pauli H.C., 1978. Internal conversion coefficients for all atomic shells, At. Data Nucl. Data Tables 21, 91-289] and also includes new Dirac-Fock calculations [Band I.M. and Trzhaskovskaya M.B., 1993. Internal conversion coefficients for low-energy nuclear transitions, At. Data Nucl. Data Tables 55, 43-61]. This database is linked to a computer program to plot ICCs and their combinations (sums and ratios) as a function of Z and energy, as well as relative deviations of ICC or their combinations for any pair of tabulated data. Examples of these analyses are presented for the K-shell and total ICCs of the gamma-ray standards [Hansen H.H., 1985. Evaluation of K-shell and total internal conversion coefficients for some selected nuclear transitions, Eur. Appl. Res. Rept. Nucl. Sci. Tech. 11.6 (4) 777-816] and for the K-shell and total ICCs of high multipolarity transitions (total, K-, L-, M-shells of E3 and M3 and K-shell of M4). Experimental data sets are also compared with the theoretical values of these specific calculations

  2. How good are the internal conversion coefficients now?

    International Nuclear Information System (INIS)

    Raman, S.; Nestor, C.W. Jr.; Ichihara, A.; Trzhaskovskaya, M.B.

    2002-01-01

    To fully utilize experimental internal conversion coefficients, one needs a reliable calculation of theoretical values. We have assembled a set of 100 experimental conversion coefficients, 45 α K and 55 α T values, measured with an accuracy of better than 5%, and generated the corresponding theoretical values using two methods, relativistic Hartree-Fock-Slater (RHFS) and relativistic Dirac-Fock (DF). Extensive comparisons of the experimental values with the two sets of theoretical values show that the DF method is clearly superior to the RHFS method in the overall reproduction of the experimental internal conversion coefficients. We discuss in some detail the differences between various versions of these two theoretical approaches, with a view to understanding which of these differences are most critical to obtaining agreement with experiment

  3. Graphical comparison of calculated internal conversion coefficients

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1980-11-01

    Calculated values of the coefficients of internal conversion of gamma rays in the K shell and L 1 , L 2 , L 3 subshells from published tabulations by Band and Trzhaskovskaya and by Roesel et al. at Data Nucl. Data Tables, 21, 92-514(1978) are compared with values obtained by computer interpolation among tabulated values of Hager and Seltzer Nucl. Data, A4, 1-235(1968). In some cases, agreement among the three calculations is remarkably good, and differences are generally less than 5%. In a few cases, there are differences as large as 20 to 50%, corresponding to the threshold effect described by Roesel et al. The Z-dependent resonance minimum described by Roesel et al. is also observed in the comparison of E1-E4 conversion in the L 1 subshell. In several cases (notably M1-M4 conversion in the K shell and L 1 subshell), the Band and Roesel calculations show dramatically different dependence on gamma energy and atomic number. For Z = 100, the Band calculation for E4 conversion in the L 3 subshell shows irregular behavior at energies below the K-shell binding energy. A few high-quality measurements of internal conversion coefficients (+-5%) would help greatly to establish a basis for choice among the theoretical calculations. 32 figures

  4. Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-02-15

    This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, '9{sup 5}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, {sup 240}Pu) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (muGyd{sup -1} per Bqkg{sup -1}) ranged from 10{sup -6} to 10{sup -2} according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as {sup 238}U, {sup 239}Pu, and {sup 240}Pu, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of {sup 239}Pu, {sup 240}Pu, {sup 238}U, {sup 14}C, {sup 3}H and {sup 99}Tc were independent of the organism

  5. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  6. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  7. Conversion coefficients and yrast state spins in 180Os

    International Nuclear Information System (INIS)

    Dracoulis, G.D.; Kibedi, T.; Byrne, A.P.; Fabricius, B.; Stuchbery, A.E.

    1989-11-01

    Internal conversion coefficients of transitions in 180 Os have been measured using a superconducting, solenoidal electron spectrometer, operated in the lens mode. The high energy resolution and efficiency allow a precise measurement of the conversion coefficients of the 528 keV yrast transition. The values obtained, α K = 0.015 (2), α L = 0.004(1) define pure E2 multipolarity. Taken with the measured γ-ray angular distribution, the conversion coefficient leads to an unambiguous assignment of 16 + →14 + for the 528 keV transition. 14 refs., 5 figs., 1 tab

  8. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  9. Systematic errors in the tables of theoretical total internal conversion coefficients

    International Nuclear Information System (INIS)

    Dragoun, O.; Rysavy, M.

    1992-01-01

    Some of the total internal conversion coefficients presented in widely used tables of Rosel et al (1978 Atom. Data Nucl. Data Tables 21, 291) were found to be erroneous. The errors appear for some low transition energies, all multipolarities, and probably for all elements. The origin of the errors is explained. The subshell conversion coefficients of Rosel et al, where available, agree with our calculations. to within a few percent. (author)

  10. Internal conversion coefficients for atomic numbers Z less than or equal to 30

    International Nuclear Information System (INIS)

    Band, I.M.; Trzhaskovskaya, M.B.; Listengarten, M.A.

    1976-01-01

    Presented here are internal conversion coefficients (ICC) of gamma rays for 20 values of atomic number, Z, in the range 3 less than or equal to Z less than or equal to 30, including all Z greater than or equal to 14. The tables provide the previously missing data for light elements. Coefficients are given for 19 values of gamma-ray transition energies up to 6 MeV for the K-electron shell and 18 values up to 2 MeV for three L-subshells. The minimum enegy is 15 keV. The first five electric and magnetic nuclear transition multipolarities are covered. The calculations are relativistic, with screening and finite nuclear size effect taken into account

  11. Study of the coefficients of internal conversion for transition energies approaching the threshold

    International Nuclear Information System (INIS)

    Farani Coursol, Nelcy.

    1979-01-01

    Internal conversion coefficients were determined experimentally with great accuracy for areas of transition energies, which constitute tests for the theories (energies at the most ten kEv above the threshold of K shell), then the results obtained were compared with the values calculated (or to be calculated) from theoretical models. Owing to the difficulties raised by the precise determination of the internal conversion coefficients (ICC), in the first stage we selected radionuclides with a relatively simple decay pattern, the transitions: 30 keV of sup(93m)Nb, 35 keV of sup(125m)Te, 14 keV of 57 Fe and 39 keV of sup(129m)Xe. It was observed that 'problems' exist with respect to the ICC's of the great multipolarity transitions, so the transitions of this kind were examined in a systematic manner. The possibility of penetration effects occurring for the transitions studied experimentally was examined. The considerations are presented which 'authorized' us to disregard the dynamic part of the ICC for the transitions approaching the threshold (L selection rules and life of nuclear levels in relation to Weisskopf-Moszkowski estimations). The Kurie straight line was determined experimentally for the β - transition and the Qsub(β) was evaluated with an important accuracy gain compared with the values available at present. Finally, a certain number of ICC's of transitions already determined with good precision were recalculated, in order to extend our analysis and detect any possible systematic errors [fr

  12. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  13. Internal conversion coefficients of high multipole transitions: Experiment and theories

    International Nuclear Information System (INIS)

    Gerl, J.; Vijay Sai, K.; Sainath, M.; Gowrishankar, R.; Venkataramaniah, K.

    2008-01-01

    A compilation of the available experimental internal conversion coefficients (ICCs), α T , α K , α L , and ratios K/L and K/LM of high multipole (L > 2) transitions for a number of elements in the range 21 ≤ Z ≤ 94 is presented. Our listing of experimental data includes 194 data sets on 110 E3 transitions, 10 data sets on 6 E4 transitions, 11 data sets on 7 E5 transitions, 38 data sets on 21 M3 transitions, and 132 data sets on 68 M4 transitions. Data with less than 10% experimental uncertainty have been selected for comparison with the theoretical values of Hager and Seltzer [R.S. Hager, E.C. Seltzer, Nucl. Data Tables A 4 (1968) 1], Rosel et al. [F. Roesel, H.M. Fries, K. Alder, H.C. Pauli, At. Data Nucl. Data Tables 21 (1978) 91], and BRICC. The relative percentage deviations (%Δ) have been calculated for each of the above theories and the averages (%Δ-bar) are estimated. The Band et al. [I.M. Band, M.B. Trzhaskovskaya, C.W. Nestor Jr., P.O. Tikkanen, S. Raman, At. Data Nucl. Data Tables 81 (2002) 1] tables, using the BRICC interpolation code, are seen to give theoretical ICCs closest to experimental values

  14. Theoretical expression of the internal conversion coefficient of a M1 transition between two atomic states

    International Nuclear Information System (INIS)

    Attallah, F.; Chemin, J.F.; Scheurer, J.N.; Karpeshin, F.; Harston, M.

    1997-01-01

    We have established a general relation for the expression of the internal conversion of an M 1 transition a 1s electronic state to an empty ns electronic bound state. Under the hypothesis that the density of the electron level ρ n satisfies the condition ρ n Γ >> 1 (where Γ is the total width of the excited atomic state) a calculation in the first order gives a relation for the internal conversion coefficient.This relation shows that the internal conversion coefficient takes a resonant character when the nuclear energy transition is smaller than the binding energy of the 1s electron. An application of this relation to an M 1 transition in the case of the ion 125 T e with a charge state Q = 45 and an 1s electron binding energy E B 45 = 35.581 KeV gives the value for the internal conversion coefficient R = 5.7

  15. Internal conversion coefficients of M4 isomeric transitions in /sup 125/ /sup 127/ /sup 129/Te decay

    Energy Technology Data Exchange (ETDEWEB)

    Soni, S K; Kumar, A; Gupta, S L; Pancholi, S C [Delhi Univ. (India). Dept. of Physics and Astrophysics

    1977-01-01

    The internal conversion coefficients have been measured using a high resolution low energy Ge(Li) detector for the following M4 transitions: /sup 125/Te: 109.27 keV transition ..cap alpha..sub(T) = 357 +- 11; RG method, /sup 127/Te: 88,26 keV transition ..cap alpha..sub(K) = 484 +- 23; XPG method, /sup 129/Te: 105.50 keV transition ..cap alpha..sub(K) = 213 +- 10; XPG method. It is observed that these values are lower by 2.5-3.6% as compared with Hager and Seltzer's calculations. A comparison between experimental and theoretical ..cap alpha..sub(K) and ..cap alpha..sub(T) values for eleven M4 transitions shows that the experimental values are systematically lower.

  16. Measurement of K-conversion coefficient of the M3 transition in sup 112 In sup m

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, K.R.; Sastry, D.L.; Reddy, K.V. (Andhra Univ., Visakhapatnam (India). Labs. for Nuclear Research); Chintalapudi, S.N. (Variable Energy Cyclotron Centre, Calcutta (India))

    1991-11-01

    The K-conversion coefficient of the 155 keV (M3) isomeric transition in the decay of {sup 112}In was measured using the normalized peak to gamma method. The {alpha}{sub K} value is found to be 4.82{+-}0.29 in agreement with the theoretical value of 5.12. (author).

  17. Pure E2 transitions: A test for BRICC Internal Conversion Coefficients

    International Nuclear Information System (INIS)

    Gerl, J.; Sai, K. Vijay; Sainath, M.; Gowrishankar, R.; Venkataramaniah, K.

    2009-01-01

    The most widely used theoretical internal conversion coefficient (ICC) tables are of Hager and Seltzer (HS), Rosel et al. and BRICC (Band et al. tables using BRICC interpolation code). A rigorous comparison of experimental ICCs with various theoretical tabulations is possible only when a large data on experimental ICCs is available at one place. For this reason, a compilation of all the available experimental ICCs, α T , α K , α L of E2 transitions for a number of elements in the range of 24≤Z≤94 is presented. Listing of experimental data includes 595 datasets corresponding to 505 E2 transitions in 165 nuclei across the nuclear chart. Data with less than 10% experimental uncertainty have been selected for comparison with the theoretical values of Hager and Seltzer, Rosel et al. and BRICC. The relative percentage deviation (%Δ) have been calculated for each of the above theories and the average (%Δ) are estimated. The Band et al. tables, using the BRICC interpolation code are seen to give theoretical ICCs closest to experimental values.

  18. The measurement of internal conversion electrons of selected nuclei: A physics undergraduate laboratory experience

    International Nuclear Information System (INIS)

    Nagy, P.; Duggan, J.L.; Desmarais, D.

    1992-01-01

    Thin sources are now commercially available for a wide variety of isotopes that have measurable internal conversion coefficients. The authors have used standard surface barrier detectors, NIM electronics, and a personal computer analyzer to measure conversion electrons from a few of these sources. Conversion electrons energy and intensity were measured for 113 Sn, 133 Ba, 137 Cs, and 207 Bi. From the measured spectra the innershell binding energies of the K ampersand L Shell electrons from the daughter nuclei were determined and compared to theory. The relative conversion coefficients a k /a L and the K/L ration were also measured. The spin and parity change of the transitions will also be assigned based on the selection rules of the transitions

  19. Observation of changing of the internal conversion coefficient under Moessbauer effect at magnetic transition in Rh-Fe system

    International Nuclear Information System (INIS)

    Ruskov, T.

    1998-01-01

    The magnetic disorder-order transition in the Rh-Fe alloy is studied by conversion electron Moessbauer spectroscopy. The drastic increase of the area under the Moessbauer spectrum at the transition from the paramagnetic to the magnetic state could be explained by diminishing the internal conversion coefficient. Thus our experimental results directly confirm the theory of the collective effect in the system of radiating developed by Yukalov

  20. Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    Science.gov (United States)

    Veinot, K G; Hertel, N E

    2012-04-01

    In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal dosemeter calibrations and in practice the personal dose equivalent is determined using a 30×30×15 cm slab-type phantom. Conversion coefficients to 1 GeV have been calculated for H(p)(10), H(p)(3) and H(p)(0.07) in the recommended slab phantom. Although the conversion coefficients were determined for discrete incident energies, analytical fits of the conversion coefficients over the energy range are provided using a similar formulation as in the photon results previously reported. The conversion coefficients for the personal dose equivalent are compared with the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection guidance. Effects of eyewear on H(p)(3) are also discussed.

  1. Standardization and determination of the total internal conversion coefficient of In-111.

    Science.gov (United States)

    Matos, Izabela T; Koskinas, Marina F; Nascimento, Tatiane S; Yamazaki, Ione M; Dias, Mauro S

    2014-05-01

    The standardization of (111)In by means of a 4πβ-γ coincidence system, composed of a proportional counter in 4π geometry, coupled to a 20% relative efficiency HPGe crystal, for measuring gamma-rays is presented. The data acquisition was performed by means of the software coincidence system (SCS) and the activity was determined by the extrapolation technique. Two gamma-ray windows were selected: at 171 keV and 245 keV total absorption peaks, allowing the determination of the total internal conversion coefficient for these two gamma transitions. The results were compared with those available in the literature. © 2013 Published by Elsevier Ltd.

  2. Methods for calculating dose conversion coefficients for terrestrial and aquatic biota

    International Nuclear Information System (INIS)

    Ulanovsky, A.; Proehl, G.; Gomez-Ros, J.M.

    2008-01-01

    Plants and animals may be exposed to ionizing radiation from radionuclides in the environment. This paper describes the underlying data and assumptions to assess doses to biota due to internal and external exposure for a wide range of masses and shapes living in various habitats. A dosimetric module is implemented which is a user-friendly and flexible possibility to assess dose conversion coefficients for aquatic and terrestrial biota. The dose conversion coefficients have been derived for internal and various external exposure scenarios. The dosimetric model is linked to radionuclide decay and emission database, compatible with the ICRP Publication 38, thus providing a capability to compute dose conversion coefficients for any nuclide from the database and its daughter nuclides. The dosimetric module has been integrated into the ERICA Tool, but it can also be used as a stand-alone version

  3. Local organ dose conversion coefficients for angiographic examinations of coronary arteries

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Hausleiter, J; Hoeschen, C

    2007-01-01

    New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average Caucasian adult man and woman as defined by the International Commission on Radiological Protection. In the 21 investigated projections, the mean organ dose conversion coefficients vary from a few 0.01 to 2 mGy(Gy cm 2 ) -1 , depending on the projections. However, especially in portions of the lungs and the active bone marrow, the conversion coefficients can locally amount up to 10 mGy(Gy cm 2 ) -1 , which is half the average conversion coefficient of the skin at the field entrance. In addition to the dose conversion coefficients, the dependence of the patient dose on the projection has been estimated. It could be shown that the patient doses are highest for left anterior oblique views with strong caudal or cranial orientation. Nevertheless, for a large range of image-intensifier positions no significant dose differences could be found

  4. Neutron fluence-to-dose conversion coefficients for embryo and fetus

    International Nuclear Information System (INIS)

    Chen, J.; Meyerhof, D.; Vlahovich, S.

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus. (authors)

  5. Neutron fluence-to-dose conversion coefficients for embryo and fetus.

    Science.gov (United States)

    Chen, Jing; Meyerhof, Dorothy; Vlahovich, Slavica

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus.

  6. Probing ultrafast ππ*/nπ* internal conversion in organic chromophores via K-edge resonant absorption

    DEFF Research Database (Denmark)

    Wolf, T. J. A.; Myhre, Rolf H.; Cryan, J. P.

    2017-01-01

    -edge soft X-ray absorption spectroscopy. As a hole forms in the n orbital during ππ*/nπ* internal conversion, the absorption spectrum at the heteroatom K-edge exhibits an additional resonance. We demonstrate the concept using the nucleobase thymine at the oxygen K-edge, and unambiguously show that ππ...

  7. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  8. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  9. Internal conversion theory of gamma radiation in unfilled atomic shells

    International Nuclear Information System (INIS)

    Anderson, Eh.M.; Trusov, V.F.; Ehglajs, M.O.

    1980-01-01

    The internal conversion theory of gamma radiation in unfilled shells, when the atom is in a state with certain energy and momentum, is considered. A formula for the conversion coefficient between the atom and ion levels is obtained. This coefficient turns to be dependent on genealogic characteristics of the atom. It is discussed when the conversion coefficients are proportional to the numbers of filling subshells in the atom. Exact calculations have been carried out in the multiconfigurational approximation taking into account intermediate coupling for the d-shell of the Fe atom Single-electron radial wave functions have been calculated on the basis of the relativistic method of the Hartree-Fock-Dirak self-consistent field. Conversion coefficients on certain subshells as well as submatrix elements of the production operator are calculated. The electric coefficient of internal conversion (CIC) in the calculation for one electron does not depend on spin orientation. That is why the electric CIC from the level will not depend on filling number distribution by subshells. For magnetic CIC the dependence on the atom state is significant. Using multiconfiguration basis for calculating energy matrix and its succeeding diagonalization means the account of the intermediate coupling type, which takes place for the unfilled shells

  10. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    International Nuclear Information System (INIS)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R.; Gallego, E.; Lorente, A.

    2012-10-01

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,θ) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  11. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A., E-mail: tzinnia.soto@gmail.com [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, Jose Gutierrez Abascal No. 2, 28006 Madrid (Spain)

    2012-10-15

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,{theta}) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  12. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    CERN Document Server

    Endo, A; Zankl, M; Bolch, W E; Eckerman, K F; Hertel, N E; Hunt, J G; Pelliccioni, M; Schlattl, H; Menzel, H-G

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.

  13. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  14. CALCULATION OF FLUENCE-TO-EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR THE OPERATIONAL QUANTITY PROPOSED BY ICRU RC26.

    Science.gov (United States)

    Endo, Akira

    2017-07-01

    Fluence-to-effective dose conversion coefficients have been calculated for photons, neutrons, electrons, positrons, protons, muons, pions and helium ions for various incident angles of radiations. The aim of this calculation is to provide a set of conversion coefficients to the Report Committee 26 (RC26) of the International Commission on Radiation Units and Measurements (ICRU) for use in defining personal dose equivalent for individual monitoring. The data sets comprise effective dose conversion coefficients for incident angles of radiations from 0° to ±90° in steps of 15° and at ±180°. Conversion coefficients for rotational, isotropic, superior hemisphere semi-isotropic and inferior hemisphere semi-isotropic irradiations are also included. Numerical data of the conversion coefficients are presented as supplementary data. The conversion coefficients are used to define the personal dose equivalent, which is being considered by the ICRU RC26, as the operational quantity for individual monitoring. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Calculation of conversion coefficients Hp(3)/K air using the PENELOPE Monte Carlo code and comparison with MCNP calculation results

    International Nuclear Information System (INIS)

    Daures, J.; Gouriou, J.; Bordy, J.M.

    2010-01-01

    The authors report calculations performed using the MNCP and PENELOPE codes to determine the Hp(3)/K air conversion coefficient which allows the Hp(3) dose equivalent to be determined from the measured value of the kerma in the air. They report the definition of the phantom, a 20 cm diameter and 20 cm high cylinder which is considered as representative of a head. Calculations are performed for an energy range corresponding to interventional radiology or cardiology (20 keV-110 keV). Results obtained with both codes are compared

  16. Method for internal conversion coefficients determination by means of a magnetic spectrometer. Application to 129Xe and 77Se

    International Nuclear Information System (INIS)

    Arqueros, F.; Campos, J.

    1986-01-01

    The method used for efficiency calibration of a magnetic electron spectrometer and its applications to conversion electron spectrometry is described. The present results point out that apparatus combining magnetic deflection and semiconductor detection have a nondecreasing interest in nuclear spectrometry for applications where good resolution and large background rejection are both necessary. The present apparatus can be employed with source of relatively low activity, (0.lμCi). The nuclides studied were 129 Xe and 77 Se resulting from 129 Cs and 77 Br decay. The parent nulcides were produced in ISOLDE on line isotope separator at CERN. The efficiency calibration method used for energies higher than 200 keV made use of the well known beta spectrum of 36 Cl. The calibration for low energies was made with Auger electron intensities and suitable conversion lines of 129 Xenon. Results for relative intensities of conversion electron lines and intense gamma lines of 129 Xe and 77 Se are given. From these measurements internal conversion coefficients for transitions of both nuclides were obtained. The results were in agreement with theoretical calculations. (author)

  17. The conversion factor of α radiation efficiency

    International Nuclear Information System (INIS)

    Wang Weida; Zhou Zhixin; Xia Junding

    1997-01-01

    It is important in fine-grain TL dating that the full α dose must be converted into the equivalent β dose. Although the conversion coefficient K for internal radiation efficiency can not be measured directly for each sample, it is possible to measure the external radiation efficiency K 3.7 . For this purpose a special study for the conversion factor of K to K 3.7 has been made using ultrathin TLD. The results show that the conversion factor of the TLD for archaeological samples is 0.847, which is in agreement with the calculated value 0.85

  18. Absorbed dose conversion coefficients for embryo and foetus in neutron fields

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    The Monte Carlo code MCNPX has been used to determine mean absorbed doses to the embryo and foetus when the mother is exposed to neutron fields. There are situations, such as on-board aircraft, where high-energy neutrons are often peaked in top down (TOP) direction. In addition to previous publications for standard irradiation geometries, this study provides absorbed dose conversion coefficients for the embryo of 8 weeks and the foetus of 3, 6 or 9 months at TOP irradiation geometry. The conversion coefficients are compared with the coefficients in isotropic irradiation (ISO). With increasing neutron energies, the conversion coefficients in TOP irradiation become dominant. A set of conversion coefficients is constructed from the higher value in either ISO or TOP irradiation at a given neutron energy. In cases where the irradiation geometry is not adequately known, this set of conversion coefficients can be used in a conservative dose assessment for embryo and foetus in neutron fields. (authors)

  19. Internal 40K radiation dose to Indians

    International Nuclear Information System (INIS)

    Ranganathan, S.; Someswara Rao, M.; Nagaratnam, A.; Mishra, U.C.

    2002-01-01

    A group of 350 Indians from both sexes (7-65 years) representing different regions of India was studied for internal 40 K radiation dose from the naturally occurring body 40 K, which was measured in the National Institute of Nutrition (NIN) whole-body counter. Although the 40 K radioactivity reached a peak value by 18 years in female (2,412 Bq) and by 20 years in male (3,058 Bq) and then varied inversely with age in both sexes, the radiation dose did not show such a trend. Boys and girls of 11 years had annual effective dose of nearly 185 mSv, which decreased during adolescence (165 mSv), increased to 175 mSv by 18-20 years in adults and decreased progressively on further ageing to 99 mSv in males and 69 mSv in females at 65 years. The observed annual effective dose (175 mSv) of the young adults was close to that of the ICRP Reference Man (176 mSv) and Indian Reference Man (175 mSv). With a mean specific activity of 55 Bq/kg for the subjects and a conversion coefficient close to 3 mSv per annum per Bq/kg, the average annual effective dose from the internal 40 K turned out to be 165 mSv for Indians. (author)

  20. Determination of the absolute K through O conversion coefficients of the 80-keV M4 transition in /sup 193/Ir/sup m/

    International Nuclear Information System (INIS)

    Lindner, M.; Gunnink, R.; Nagle, R.J.

    1987-01-01

    We produced carrier-free, nearly isotopically pure /sup 193/Ir/sup m/ from thermal-neutron irradiation of /sup 192/Os. From studies of the conversion-electron spectrum, the photon spectrum, and the absolute counting rates, we determined the absolute K, L1, L2, L3, M1, M3, M5, N, and O+P conversion coefficients for the first time. With possibly one exception, these values agree closely with theoretical calculations. The value for the energy of the unconverted gamma ray was found to be 80.22 +- 0.02 keV. The half-life for /sup 193/Ir/sup m/ determined by absolute electron counting in a proportional counter of 100% counting efficiency (4πβ) was found to be 10.53 +- 0.04 d. We have determined the L 1 subshell fluorescence yield, ω 1 , to be 0.120 +- 0.003 for iridium. Based upon our measurements of initial and final L subshell vacancies together with a best-fit literature value for ω 2 , we have found a plausible value for the Coster-Kronig coefficient f/sub 12/ to be 0.091 +- 0.011

  1. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    Science.gov (United States)

    Schlattl, H.; Zankl, M.; Petoussi-Henss, N.

    2007-04-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

  2. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Petoussi-Henss, N

    2007-01-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360 deg. rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%

  3. Outlines of ICRP publication 74 and new dose conversion coefficients for external radiation

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1998-01-01

    Combined task group of ICRP and ICRU reported the ICRP Publication 74 (1996) which is a summary report of their collection, analysis and evaluation of many data and dose conversion coefficients. Concerning the new coefficients, the author described this review as follows: History until Publication 74. Doses recommended at present: for protection quantity, the mean absorption dose of organ and tissue, equivalent dose and effective dose and for operational quantity, the ambient dose equivalent, directional dose equivalent and individual dose equivalent. Changes which can have an influence on the dose evaluation; introduction of radiation weighting factor (WR), changing of tissue weighting factor (WR), changing of the equation for Q-L relation and updating of physical data. New dose conversion coefficients; for photon, neutron and electron. Comparison of new and present coefficients; concerning the quality factor Q, particularly for neutron Q. New relations of protection and operational quantities; for field and individual monitoring. General conclusion of Publication 74. The Publication gives a certain direction for problems in evaluation of external exposure dose which have been discussed since the ICRP Fundamental Recommendation 1990 was issued. However, there still remain many problems especially in validity of the WR and of equation for Q-L relation. (K.H.)

  4. Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Becker, J; Hoeschen, C

    2012-01-01

    A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI vol for an eight-week-old baby and seven- and eight-year-old children have been computed accounting for TCM. The relative difference in organ dose conversion coefficients with and without TCM is for many organs and examinations less than 10%, but can in some cases amount up to 30%, e.g., for the thyroid in the chest CT of the seven-year-old child. Overall, the impact of TCM on the conversion coefficients increases with increasing age. Besides TCM, also the effect of collimation and tube voltage on organ dose conversion coefficients has been investigated. It could be shown that the normalization to CTDI vol leads to conversion coefficients that can in most cases be considered to be independent of collimation and tube voltage. (paper)

  5. Dose conversion coefficients for photon exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  6. Dose conversion coefficients for photon exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H p (3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  7. Conversion coefficients for determining organ doses in paediatric spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, Michael; Schneider, Karl [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology - Paediatric Radiology, Muenchen (Germany)

    2014-04-15

    Knowledge of organ and effective doses achieved during paediatric x-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for segmental spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional segmental spine radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during cervical, thoracic and lumbar spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal and lateral beam projections and the standard focus detector distance of 115 cm. The conversion coefficients presented may be used for organ dose assessments from entrance doses measured during spine radiographs of patients of all age groups and all field settings within the optimal and suboptimal standard field settings. (orig.)

  8. Ideal related K-theory with coefficients

    DEFF Research Database (Denmark)

    Eilers, Soren; Restorff, Gunnar; Ruiz, Efren

    2017-01-01

    In this paper, we define an invariant, which we believe should be the substitute for total K-theory in the case when there is one distinguished ideal. Moreover, some diagrams relating the new groups to the ordinary K-groups with coefficients are constructed. These diagrams will in most cases help...... to determine the new groups, and will in a companion paper be used to prove a universal multi-coefficient theorem for the one distinguished ideal case for a large class of algebras......In this paper, we define an invariant, which we believe should be the substitute for total K-theory in the case when there is one distinguished ideal. Moreover, some diagrams relating the new groups to the ordinary K-groups with coefficients are constructed. These diagrams will in most cases help...

  9. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  10. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  11. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation

    International Nuclear Information System (INIS)

    Qiu, R.; Li, J.; Zhang, Z.; Liu, L.; Bi, L.; Ren, L.

    2009-01-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface. (authors)

  12. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation.

    Science.gov (United States)

    Qiu, Rui; Li, Junli; Zhang, Zhan; Liu, Liye; Bi, Lei; Ren, Li

    2009-02-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface.

  13. Calculation of conversion coefficients for radiological protection against external radiation exposures

    International Nuclear Information System (INIS)

    Zankl, M.

    2001-01-01

    Calculations are essential for radiation protection practice because organ doses and effective doses cannot be measured directly. Conversion coefficients describe the numerical relationships of protection quantities and operational quantities. The latter can be measured in practical situations using suitable dosimeters. The conversion coefficients are calculated using radiation transport codes - usually based on Monte Carlo methods - that simulate the interactions of radiation with matter in computational models of the human body. A new generation of human body models, the so-called voxel models, are constructed from image data of real persons using suitable image processing systems, consequently, they represent the human anatomy more realistically than the so-called mathematical models. The numerical effects of realistic body anatomy on the calculated conversion coefficients can amount to 70% and more for external exposures. (orig.) [de

  14. Role of nuclear penetration effects in spin assignments. [J, transitions, internal conversion

    Energy Technology Data Exchange (ETDEWEB)

    Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1976-04-01

    Nuclear penetrations have been found to affect the internal conversion process of the retarded magnetic dipole transitions. In all cases where the penetration coefficient has been found to be essentially different from unity the transition is 1-forbidden. This criterian has been applied to the case of 191 keV transition in /sup 197/Au where the spin of the 268 keV level could not be deduced uniquely by any of the existing methods. The result is that the 199 keV transition has a dynamic contribution to its internal conversion process with the penetration coefficient lambda = 5.5 +- 0.9. To illustrate the applicability of the criterian further two more cases namely that of the 92 keV transition in /sup 131/Cs and 182 keV transition in /sup 129/Cs are also included.

  15. Internal friction and linear expansion coefficient in zirconium and cobalt within the range of phase transitions

    International Nuclear Information System (INIS)

    Boyarskij, S.V.

    1986-01-01

    Experimental results are presented for internal friction and linear expansion coefficient at zirconium and cobalt in the temperature range from 440 K to the point of the phase transition of the first kind (1138 K for Zr and 706 for Co). Anomalous changes of the internal friction and linear expansion coefficient in the phase transition region are found. Theoretical considerations are given to explain the sharp decrease of the internal friction as temperature approaches the phase transition point

  16. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2015-09-01

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D PMMA (10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K a obtaining a value of 1.20 Sv Gy -1 with a u c = 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy -1 with a u c = 2%. (Author)

  17. Penetration effect in internal conversion and nuclear structure

    International Nuclear Information System (INIS)

    Listengarten, M.A.

    1978-01-01

    The conditions for the appearance of the anomalous internal conversion coefficients (ICC) are considered, when the contribution of the penetration matrix element (PME) is of the order of or larger than the main part of the conversion matrix element. The experimental magnitudes of the nuclear PME agree well with those calculated in the framework of simple nuclear models, provided the magnitude of PME is not decreased due to the model -dependent selection rules. The magnitude of the anomaly ( lanbda parameter ) is compared with the exclusion factor of γ-transition relative to the Weisskopf estimation. The better is the model of the nucleus the weaker is the dependence of the lambda magnitude on the exclusion factor. ICC coefficients might be anomalous for those γ-transitions for which the exclusion factor calculated in the framework of more rigorous model are of the order of unity. In the ''ideal'' model of nucleus completely adequate to the true nuclear structure the dependence of the lambda penetration parameter on the exclusion factor vanishes

  18. Internal conversion in highly stripped 83Kr ions

    International Nuclear Information System (INIS)

    Copnell, J.; Phillips, W.R.; Barnett, A.R.; Rehm, K.E.; Ahmad, I.; Gehring, J.; Glagola, B.G.; Kutschera, W.

    1995-01-01

    The total decay probabilities per unit time of the first excited 9.4-keV state in 83 Kr have been measured in ions of ionicity q from 28 to 32. Using a γ-decay probability per unit time of 0.255(2)x10 6 s -1 gives internal conversion coefficients of 14.6(11), 14.9(10), 14.1(9), 14.6(11), and 15.2(24) for q=28--32, respectively. These values are compared with theoretical predictions

  19. Calculation of conversion coefficients for clinical photon spectra using the MCNP code.

    Science.gov (United States)

    Lima, M A F; Silva, A X; Crispim, V R

    2004-01-01

    In this work, the MCNP4B code has been employed to calculate conversion coefficients from air kerma to the ambient dose equivalent, H*(10)/Ka, for monoenergetic photon energies from 10 keV to 50 MeV, assuming the kerma approximation. Also estimated are the H*(10)/Ka for photon beams produced by linear accelerators, such as Clinac-4 and Clinac-2500, after transmission through primary barriers of radiotherapy treatment rooms. The results for the conversion coefficients for monoenergetic photon energies, with statistical uncertainty <2%, are compared with those in ICRP publication 74 and good agreements were obtained. The conversion coefficients calculated for real clinic spectra transmitted through walls of concrete of 1, 1.5 and 2 m thick, are in the range of 1.06-1.12 Sv Gy(-1).

  20. Problems is applying new internal dose coefficients to radiation control

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi [Oarai Laboratory, Chiyoda Technol Corporation, Ibaraki (Japan)

    1998-06-01

    The author discussed problems concerning the conceivable influence in the radiation control and those newly developing when the new internal dose coefficients are applied in the law in the future. For the conceivable influence, the occupational and public exposure was discussed: In the former, the effective dose equivalent limit (at present, 50 mSv/y) was thought to be reduced and in the latter, the limit to be obscure although it might be more greatly influenced by the new coefficients. For newly developing problems, since the new biological model which is more realistic was introduced for calculation of the internal dose and made the calculation more complicated, use of computer is requisite. The effective dose of the internal exposure in the individual monitoring should be conveniently calculated as done at present even after application of the new coefficients. For calculation of the effective dose of the internal exposure, there are such problems as correction of the inhaled particle size and of the individual personal parameter. A model calculation of residual rate in the chest where the respiratory tract alone participated was presented as an example but for the whole body, more complicated functions were pointed out necessary. The concept was concluded to be incorporated in the law in a convenient and easy manner and a software for calculation of internal dose using the new coefficients was wanted. (K.H.)

  1. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

  2. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    International Nuclear Information System (INIS)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment

  3. Applicability of dose conversion coefficients of ICRP 74 to Asian adult males: Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Lee, Jai-Ki

    2007-01-01

    International Commission on Radiological Protection (ICRP) reported comprehensive dose conversion coefficients for adult population, which is exposed to external photon sources in the Publication 74. However, those quantities were calculated from so-called stylized (or mathematical) phantoms composed of simplified mathematical surface equations so that the discrepancy between the phantoms and real human anatomy has been investigated by several authors using Caucasian-based voxel phantoms. To address anatomical and racial limitations of the stylized phantoms, several Asian-based voxel phantoms have been developed by Korean and Japanese investigators, independently. In the current study, photon dose conversion coefficients of ICRP 74 were compared with those from a total of five Asian-based male voxel phantoms, whose body dimensions were almost identical. Those of representative radio-sensitive organs (testes, red bone marrow, colon, lungs, and stomach), and effective dose conversion coefficients were obtained for comparison. Even though organ doses for testes, colon and lungs, and effective doses from ICRP 74 agreed well with those from Asian voxel phantoms within 10%, absorbed doses for red bone marrow and stomach showed significant discrepancies up to 30% which was mainly attributed to difference of phantom description between stylized and voxel phantoms. This study showed that the ICRP 74 dosimetry data, which have been reported to be unrealistic compared to those from Caucasian-based voxel phantoms, are also not appropriate for Asian population

  4. Photon dose conversion coefficients for the human teeth in standard irradiation geometries

    Energy Technology Data Exchange (ETDEWEB)

    Ulanovsky, A; Wieser, A; Zankl, M; Jacob, P

    2005-07-01

    Photon dose conversion coefficients for the human tooth materials are computed in energy range from 0.01 to 10 MeV by the Monte Carlo method. The voxel phantom Golem of the human body with newly defined tooth region and a modified version of the EGS4 code have been used to compute the coefficients for 30 tooth cells with different locations and materials. The dose responses are calculated for cells representing buccal and lingual enamel layers. The computed coefficients demonstrate a strong dependence on energy and geometry of the radiation source and a weaker dependence on location of the enamel voxels. For isotropic and rotational radiation fields the enamel dose does not show a significant dependence on tooth sample locations. The computed coefficients are used to convert from absorbed dose in teeth to organ dose or to integral air kerma. Examples of integral conversion factors from enamel dose to air kerma are given for several photon fluences specific for the Mayak reprocessing plant in Russia. The integral conversion factors are strongly affected by the energy and angular distributions of photon fluence, which are important characteristics of an exposure scenario for reconstruction of individual occupational doses. (orig.)

  5. Friction coefficient and limiter load test analysis by flexibility coefficient model of Hold-Down Spring of nuclear reactor vessel internals

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Linjun [Zhejiang Univ. of Technology, Hangzhou (China). College of Mechanical Engineering; Xue, Guohong; Zhang, Ming [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China)

    2017-11-15

    The friction force between the contact surfaces of a reactor internal hold-down spring (HDS) and core barrel flanges can directly influence the axial stiffness of an HDS. However, friction coefficient cannot be obtained through theoretical analysis. This study performs a mathematical deduction of the physical model of an HDS. Moreover, a mathematical model of axial load P, displacement δ, and flexibility coefficient is established, and a set of test apparatuses is designed to simulate the preloading process of the HDS. According to the experimental research and theoretical analysis, P-δ curves and the flexibility coefficient λ are obtained in the loading processes of the HDS. The friction coefficient f of the M1000 HDS is further calculated as 0.224. The displacement limit load value (4,638 kN) can be obtained through a displacement limit experiment. With the friction coefficient considered, the theoretical load is 4,271 kN, which is relatively close to the experimental result. Thus, the friction coefficient exerts an influence on the displacement limit load P. The friction coefficient should be considered in the design analysis for HDS.

  6. Friction coefficient and limiter load test analysis by flexibility coefficient model of Hold-Down Spring of nuclear reactor vessel internals

    International Nuclear Information System (INIS)

    Xie, Linjun

    2017-01-01

    The friction force between the contact surfaces of a reactor internal hold-down spring (HDS) and core barrel flanges can directly influence the axial stiffness of an HDS. However, friction coefficient cannot be obtained through theoretical analysis. This study performs a mathematical deduction of the physical model of an HDS. Moreover, a mathematical model of axial load P, displacement δ, and flexibility coefficient is established, and a set of test apparatuses is designed to simulate the preloading process of the HDS. According to the experimental research and theoretical analysis, P-δ curves and the flexibility coefficient λ are obtained in the loading processes of the HDS. The friction coefficient f of the M1000 HDS is further calculated as 0.224. The displacement limit load value (4,638 kN) can be obtained through a displacement limit experiment. With the friction coefficient considered, the theoretical load is 4,271 kN, which is relatively close to the experimental result. Thus, the friction coefficient exerts an influence on the displacement limit load P. The friction coefficient should be considered in the design analysis for HDS.

  7. Conversion coefficients for individual monitoring calculated with integrated tiger series, ITS3, Monte Carlo code

    International Nuclear Information System (INIS)

    Devine, R.T.; Hsu, Hsiao-Hua

    1994-01-01

    The current basis for conversion coefficients for calibrating individual photon dosimeters in terms of dose equivalents is found in the series of papers by Grosswent. In his calculation the collision kerma inside the phantom is determined by calculation of the energy fluence at the point of interest and the use of the mass energy absorption coefficient. This approximates the local absorbed dose. Other Monte Carlo methods can be sued to provide calculations of the conversion coefficients. Rogers has calculated fluence-to-dose equivalent conversion factors with the Electron-Gamma Shower Version 3, EGS3, Monte Carlo program and produced results similar to Grosswent's calculations. This paper will report on calculations using the Integrated TIGER Series Version 3, ITS3, code to calculate the conversion coefficients in ICRU Tissue and in PMMA. A complete description of the input parameters to the program is given and comparison to previous results is included

  8. Simulation codes to evcaluate dose conversion coefficients for hadrons over 10 GeV

    International Nuclear Information System (INIS)

    Sato, T.; Tsuda, S.; Sakamoto, Y.; Yamaguchi, Y.; Niita, K.

    2002-01-01

    The conversion coefficients from fluence to effective dose for high energy hadrons are indispensable for various purposes such as accelerator shielding design and dose evaluation in space mission. Monte Carlo calculation code HETC-3STEP was used to evaluate dose conversion coefficients for neutrons and protons up to 10 GeV with an anthropomorphic model. The scaling model was incorporated in the code for simulation of high energy nuclear reactions. However, the secondary particle energy spectra predicted by the model were not smooth for nuclear reactions over several GeV. We attempted, therefore, to simulate transportation of such high energy particles by two newly developed Monte Carlo simulation codes: one is HETC-3STEP including the model used in EVENTQ instead of the scaling model, and the other is NMTC/JAM. By comparing calculated cross sections by these codes with experimental data for high energy nuclear reactions, it was found that NMTC/JAM had a better agreement with the data. We decided, therefore, to adopt NMTC/JAM for evaluation of dose conversion coefficients for hadrons with energies over 10 GeV. The effective dose conversion coefficients for high energy neutrons and protons evaluated by NMTC/JAM were found to be close to those by the FLUKA code

  9. Fluence to Dose Equivalent Conversion Coefficients for Evaluation of Accelerator Radiation Environments

    International Nuclear Information System (INIS)

    Thomas, Ralph H.; Zeman, Gary H.

    2001-01-01

    The derivation of a set of conversion functions for the expression of neutron fluence measurements in terms of Effective Dose, E, is described. Four functions in analytical form are presented, covering the neutron energy range from 2.5 10-8 to 10+4 MeV, for the interpretation of fluence measurements in the typical irradiation conditions experienced around high-energy proton accelerators such as the Bevatron. For neutron energies below 200 MeV the analytical functions were modeled after the ISO and ROT conversion coefficients in ICRU 57. For neutron energies above 200 MeV, the analytical function was derived from an analysis of recent published data. Sample calculations using either the analytical expressions or the tabulated conversion coefficients from which the analytical expressions are derived show agreement to better than plus/minus 5%

  10. Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography

    International Nuclear Information System (INIS)

    Seidenbusch, Michael C.; Schneider, Karl

    2014-01-01

    Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm. The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings. (orig.)

  11. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  12. Discourse analysis: Conversational analysis of the internal conversation in Oracle Corporation Malaysia

    Directory of Open Access Journals (Sweden)

    Marwa Marwa

    2017-07-01

    Full Text Available This study highlights the internal conversation which takes place in Oracle CorporationMalaysia. Through the study, it will be shown how conversational analysis is used toanalyze the transcription of a telephone conversation between Oracle staffs. The analysisof the transcriptions will apply a few basic concepts of conversational analysis; turntakingorganization, and the adjacency pair. The objective of the study is to find out howthe internal conversations takes place by focusing on the conversation itself, that is, theconversational structures spontaneously produced by people during talk ranging fromturn-taking strategies, how topics are introduced, conversation closings and so on. Bylooking in detail at such talk, we can gain a detailed understanding of how the staffs seethemselves in relation to the company that influence their daily lives.Keywords: conversational analysis, turn-taking, adjacency pairs

  13. Comparing two K-category assignments by a K-category correlation coefficient

    DEFF Research Database (Denmark)

    Gorodkin, Jan

    2004-01-01

    Predicted assignments of biological sequences are often evaluated by Matthews correlation coefficient. However, Matthews correlation coefficient applies only to cases where the assignments belong to two categories, and cases with more than two categories are often artificially forced into two...... categories by considering what belongs and what does not belong to one of the categories, leading to the loss of information. Here, an extended correlation coefficient that applies to K-categories is proposed, and this measure is shown to be highly applicable for evaluating prediction of RNA secondary...

  14. The Non-Ergodic Nature of Internal Conversion

    DEFF Research Database (Denmark)

    Sølling, Theis I.; Kuhlman, Thomas Scheby; Stephansen, Anne B.

    2014-01-01

    The absorption of light by molecules can induce ultrafast dynamics and coupling of electronic and nuclear vibrational motion. The ultrafast nature in many cases rests on the importance of several potential energy surfaces in guiding the nuclear motion—a concept of central importance in many aspects...... of chemical reaction dynamics. This Minireview focuses on the non-ergodic nature of internal conversion, that is, on the concept that the nuclear dynamics only sample a reduced phase space, potentially resulting in localization of the dynamics in real space. A series of results that highlight...... it takes to reach it. 2) Localization of energy into a single reactive mode, which is dictated by the internal conversion process. 3) Initiation of the internal conversion by activation of a single complex motion, which then specifically couples to a reactive mode. 4) Nonstatistical internal conversion...

  15. New quantities in radiation protection and conversion coefficients

    International Nuclear Information System (INIS)

    1986-01-01

    Four new quantities have been proposed by the ICRP for use in radiation protection from external sources, i.e. the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent (penetrating), and the individual dose equivalent (superficial). These quantities are briefly described together with two new concepts of expanded and aligned fields. The BCRU recommends that these quantities should be adopted for use in the UK together with conversion coefficients when re-calibrating existing instruments, reporting the results of measurements and designing instruments. (UK)

  16. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination.

    Science.gov (United States)

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-21

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm -2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an

  17. Delimiting Coefficient a from Internal Consistency and Unidimensionality

    Science.gov (United States)

    Sijtsma, Klaas

    2015-01-01

    I discuss the contribution by Davenport, Davison, Liou, & Love (2015) in which they relate reliability represented by coefficient a to formal definitions of internal consistency and unidimensionality, both proposed by Cronbach (1951). I argue that coefficient a is a lower bound to reliability and that concepts of internal consistency and…

  18. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  19. Research on friction coefficient of nuclear Reactor Vessel Internals Hold Down Spring: Stress coefficient test analysis method

    International Nuclear Information System (INIS)

    Linjun, Xie; Guohong, Xue; Ming, Zhang

    2016-01-01

    Graphical abstract: HDS stress coefficient test apparatus. - Highlights: • This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. • The mathematical relation between the load and the strain is obtained about the HDS, and the mathematical model of the stress coefficient and the friction coefficient is established. So, a set of test apparatuses for obtaining the stress coefficient is designed according to the model scaling criterion and the friction coefficient of the K1000 HDS is calculated to be 0.336 through the obtained stress coefficient. • The relation curve between the theoretical load and the friction coefficient is obtained through analysis and indicates that the change of the friction coefficient f would influence the pretightening load under the condition of designed stress. The necessary pretightening load in the design process is calculated to be 5469 kN according to the obtained friction coefficient. Therefore, the friction coefficient and the pretightening load under the design conditions can provide accurate pretightening data for the analysis and design of the reactor HDS according to the operations. - Abstract: This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. By carrying out tests and researches through a stress testing technique, P–σ curves in loading and unloading processes of the HDS are obtained and the stress coefficient k f of the HDS is obtained. So, the

  20. Research on friction coefficient of nuclear Reactor Vessel Internals Hold Down Spring: Stress coefficient test analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Linjun, Xie, E-mail: linjunx@zjut.edu.cn [College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014 (China); Guohong, Xue; Ming, Zhang [Shanghai Nuclear Engineering Research & Design Institute, Shanghai 200233 (China)

    2016-08-01

    Graphical abstract: HDS stress coefficient test apparatus. - Highlights: • This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. • The mathematical relation between the load and the strain is obtained about the HDS, and the mathematical model of the stress coefficient and the friction coefficient is established. So, a set of test apparatuses for obtaining the stress coefficient is designed according to the model scaling criterion and the friction coefficient of the K1000 HDS is calculated to be 0.336 through the obtained stress coefficient. • The relation curve between the theoretical load and the friction coefficient is obtained through analysis and indicates that the change of the friction coefficient f would influence the pretightening load under the condition of designed stress. The necessary pretightening load in the design process is calculated to be 5469 kN according to the obtained friction coefficient. Therefore, the friction coefficient and the pretightening load under the design conditions can provide accurate pretightening data for the analysis and design of the reactor HDS according to the operations. - Abstract: This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. By carrying out tests and researches through a stress testing technique, P–σ curves in loading and unloading processes of the HDS are obtained and the stress coefficient k{sub f} of the HDS is obtained. So, the

  1. Liquid phase PVTx properties of (water + tert-butanol) binary mixtures at temperatures from 278.15 to 323.15 K and pressures from 0.1 to 100 MPa. II. Molar isothermal compressions, molar isobaric expansions, molar thermal pressure coefficients, and internal pressure

    International Nuclear Information System (INIS)

    Egorov, Gennadiy I.; Makarov, Dmitriy M.; Kolker, Arkadiy M.

    2013-01-01

    Highlights: ► Molar isothermal compressions and molar isobaric expansions were evaluated. ► Coefficients of thermal pressure and internal pressure were obtained. ► Concentration dependences of coefficients under study display extremes. ► Temperature and pressure dependences of internal pressure of the mixture were linear. -- Abstract: Molar isothermal compressions, molar isobaric expansions, molar coefficients of thermal pressure, and internal pressure were calculated over the whole concentration range of {water (1) + tert-butanol (2)} mixture at pressures from 0.1 to 100 MPa and temperatures from 278.15 to 323.15 K. It was revealed that the extremes, observed on concentration dependences of molar isothermal compression K T,m and molar isobaric expansion E P,m of the mixture, became more pronounced with pressure growth and temperature lowering. Values of molar thermal pressure coefficients of the mixture sharply rose at compositions with small TBA mole fraction and then decreased practically linearly with the alcohol content increasing. Temperature and pressure dependences of the mixture internal pressure were almost linear, and at low TBA concentrations changed significantly from the dependences of water, tert-butanol and their mixtures at large alcohol content

  2. Dose conversion coefficients calculated using a series of adult Japanese voxel phantoms against external photon exposure

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2008-10-01

    This report presents a complete set of conversion coefficients of organ doses and effective doses calculated for external photon exposure using five Japanese adult voxel phantoms developed at the Japan Atomic Energy Agency (JAEA). At the JAEA, high-resolution Japanese voxel phantoms have been developed to clarify the variation of organ doses due to the anatomical characteristics of Japanese, and three male phantoms (JM, JM2 and Otoko) and two female phantoms (JF and Onago) have been constructed up to now. The conversion coefficients of organ doses and effective doses for the five voxel phantoms have been calculated for six kinds of idealized irradiation geometries from monoenergetic photons ranging from 0.01 to 10 MeV using EGS4, a Monte Carlo code for the simulation of coupled electron-photon transport. The dose conversion coefficients are given as absorbed dose and effective dose per unit air-kerma free-in-air, and are presented in tables and figures. The calculated dose conversion coefficients are compared with those of voxel phantoms based on the Caucasian and the recommended values in ICRP74 in order to discuss (1) variation of organ dose due to the body size and individual anatomy, such as position and shape of organs, and (2) effect of posture on organ doses. The present report provides valuable data to study the influence of the body characteristics of Japanese upon the organ doses and to discuss developing reference Japanese and Asian phantoms. (author)

  3. Measuring international relations in social media conversations

    OpenAIRE

    Barnett, GA; Xu, WW; Chu, J; Jiang, K; Huh, C; Park, JY; Park, HW

    2017-01-01

    © 2016 Elsevier Inc. This paper examines international relations as perceived by the public in their social media conversations. It examines over 1.8 billion Facebook postings in English and 51 million Chinese posts on Weibo, to reveal the relations among nations as expressed in social media conversations. It argues that social media represent a transnational electronic public sphere, in which public discussions reveal characteristics of international relations as perceived by a foreign publi...

  4. Electron spectrometers with internal conversion

    International Nuclear Information System (INIS)

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  5. The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code.

    Science.gov (United States)

    Zhang, Bintuan; Dang, Bingrong; Wang, Zhuanzi; Wei, Wei; Li, Wenjian

    2013-10-01

    The skin tissue-equivalent slab reported in the International Commission on Radiological Protection (ICRP) Publication 116 to calculate the localised skin dose conversion coefficients (LSDCCs) was adopted into the Monte Carlo transport code Geant4. The Geant4 code was then utilised for computation of LSDCCs due to a circular parallel beam of monoenergetic electrons, protons and alpha particles electrons and alpha particles are found to be in good agreement with the results using the MCNPX code of ICRP 116 data. The present work thus validates the LSDCC values for both electrons and alpha particles using the Geant4 code.

  6. Organ dose conversion coefficients based on a voxel mouse model and MCNP code for external photon irradiation.

    Science.gov (United States)

    Zhang, Xiaomin; Xie, Xiangdong; Cheng, Jie; Ning, Jing; Yuan, Yong; Pan, Jie; Yang, Guoshan

    2012-01-01

    A set of conversion coefficients from kerma free-in-air to the organ absorbed dose for external photon beams from 10 keV to 10 MeV are presented based on a newly developed voxel mouse model, for the purpose of radiation effect evaluation. The voxel mouse model was developed from colour images of successive cryosections of a normal nude male mouse, in which 14 organs or tissues were segmented manually and filled with different colours, while each colour was tagged by a specific ID number for implementation of mouse model in Monte Carlo N-particle code (MCNP). Monte Carlo simulation with MCNP was carried out to obtain organ dose conversion coefficients for 22 external monoenergetic photon beams between 10 keV and 10 MeV under five different irradiation geometries conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic). Organ dose conversion coefficients were presented in tables and compared with the published data based on a rat model to investigate the effect of body size and weight on the organ dose. The calculated and comparison results show that the organ dose conversion coefficients varying the photon energy exhibits similar trend for most organs except for the bone and skin, and the organ dose is sensitive to body size and weight at a photon energy approximately <0.1 MeV.

  7. Investigation of the Buckling-Reactivity Conversion Coefficient using SRAC and MVP codes for UO2 Lattices in TCA experiments

    International Nuclear Information System (INIS)

    Le Dai Dien

    2008-01-01

    Benchmark experiments for International Reactor Physics Benchmark Experiments (IRPhE) Project carried out at TCA, the temperature effects on reactivity were studied for light water moderated and reflected UO 2 cores with/without soluble poisons. The buckling coefficient method using the measured critical water levels was proposed by Suzaki et al. The temperature dependence of buckling coefficient of reactivity and its variance by the core configurations of the benchmark experiments was investigated using SRAC and MVP calculations. From the calculations by SRAC as well as by MVP it is seen that the K-value can be taken as an average value only for each core with temperature changes which are considered as perturbation parameter. The difference between our calculations and benchmark results which uses constant K-value for all cores proves that the results depend on K-value and it play important role in defining reactivity effect using the water level worth method. (author)

  8. The Disintegration of {sup 103}Rh{sup m}

    Energy Technology Data Exchange (ETDEWEB)

    Czock, K. H.; Haselberger, N.; Reichel, F. [International Atomic Energy Agency, Vienna (Austria)

    1974-09-15

    A technique for determination of the disintegration rate of {sup 103}Rh{sup m} in thick foils is described. In addition values for the following parameters were determined: - total internal conversion coefficient {alpha} = 1531 {+-} 30; - K shell internal conversion coefficient {alpha}{sub K} = 127 {+-} 6; - conversion ratio R= K/L+M+..... = 0.0914 {+-} 0.0043. (author)

  9. Determination of conversion factors of kerma and fluence to ambient dose equivalent for X-rays generated between 50 kVp to 125 kVp

    International Nuclear Information System (INIS)

    Nogueira, Maria do Socorro

    1997-01-01

    The ambient dose equivalent was determined experimentally on the interval of energy of X ray applied in diagnostic radiology. A PMMA sphere was used to simulate the trunk human (phantom), based on the definition of the report ICRU 39. The absorbed dose in different positions in the phantom was determined using LiF-TLD 100. The X ray spectra were measured with a high-purity germanium detector (HP Ge). It was also determined the HVL and the effective energy in this energy range. The conversion coefficient of the K air and Φ to H * (d) were determined to 10, 50 and 60 mm deep in the PMMA sphere. The obtained values were compared with data of the literature. The maximum uncertainty obtained for the coefficients was 7.2%. All parameters were also determined to the X ray quality of the incident and transmitted beam by the patient, according to the recommendation of the standard DIN 6872. The conversion factor was calculated for those situations where the X-ray beam is transmitted by a layer and Pb and it is necessary to estimate the effective dose, as in the case of shielding project of radiology diagnosis room. (author)

  10. Delimiting coefficient alpha from internal consistency and unidimensionality

    NARCIS (Netherlands)

    Sijtsma, K.

    2015-01-01

    I discuss the contribution by Davenport, Davison, Liou, & Love (2015) in which they relate reliability represented by coefficient α to formal definitions of internal consistency and unidimensionality, both proposed by Cronbach (1951). I argue that coefficient α is a lower bound to reliability and

  11. SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Q [Institute of Radiation Medicine Fudan University, Shanghai (China); Shanghai General Hospital, Shanghai, Shanghai (China); Zhuo, W; Liu, H [Institute of Radiation Medicine Fudan University, Shanghai (China); Liu, Y; Chen, T [Shanghai General Hospital, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

  12. SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

    International Nuclear Information System (INIS)

    Liu, Q; Zhuo, W; Liu, H; Liu, Y; Chen, T

    2016-01-01

    Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

  13. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  14. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4

    International Nuclear Information System (INIS)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R.

    2014-01-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H p (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm 3 , composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm 2 ). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  15. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements; Determinacion del coeficiente de conversion para la dosis equivalente ambiental, H*(10), a partir de mediciones de kerma en aire

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, F. [UNAM, Facultad de Ciencias, Circuito Exterior, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D{sub PMMA}(10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K{sub a} obtaining a value of 1.20 Sv Gy{sup -1} with a u{sub c}= 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy{sup -1} with a u{sub c}= 2%. (Author)

  16. Calibration of the isomer shift of {sup 133}Cs from internal conversion measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Hiroko; Tanaka, Eiji; Muramatsu, Hisakazu [Shinshu Univ., Matsumoto, Nagano (Japan)] [and others

    1997-03-01

    In this study, for 81 KeV transition of 133-Cs which is one of Moessbauer nuclides belonged to alkaline element and can be useful probe on study of binding state in a compound with high ionic boundability specific to alkaline element, an experiment to obtain {Delta}R/R was conducted by measurement of Moessbauer isomer shift and of internal conversion intensity of outer shell electron, using an internal conversion method, one of obtaining methods of {Delta} at the most accuracy. 133-Xe was buried at shallow surface of a host metal, reduced energy loss of internal conversion electron to realize high resolution and aimed to separate O-shell from P-shell to reduce injected ionic spaced and prepare a source. In range measurement of various energy to confirm actual speed reduction of ion, transmittance of 133-Xe on Cu layer vapor-deposited 2 to 10 micro g/sq cm thick on an Ni-foil was conducted. As a result, mean ranges of each energy were 5:2.2, 10:3.7, 15:4.8, and 20:5.6 micro g/sq cm, respectively. It was thought to be proved that speed reduction was certainly conducted by facts that the range increased with increase of the incident energy which showed good agreement with calculation results due to TRIM-95 code. (G.K.)

  17. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  18. determination of reaeration coefficient k2 for polluted stream as a ...

    African Journals Online (AJOL)

    include velocity of flow, average depth of flow, DO, self purification ratio (f) and reaeration constant (K2). ... Determination of Reaeration Reaeration Coefficient K2 for Polluted Stream. 175. Table 1: ... and theory on which it is based. The result ...

  19. Thermoelectric conversion efficiency in IV-VI semiconductors with reduced thermal conductivity

    Directory of Open Access Journals (Sweden)

    Akihiro Ishida

    2015-10-01

    Full Text Available Mid-temperature thermoelectric conversion efficiencies of the IV-VI materials were calculated under the Boltzmann transport theory of carriers, taking the Seebeck, Peltier, and Thomson effects into account. The conversion efficiency was discussed with respect to the lattice thermal conductivity, keeping other parameters such as Seebeck coefficient and electrical conductivity to the same values. If room temperature lattice thermal conductivity is decreased up to 0.5W/mK, the conversion efficiency of a PbS based material becomes as high as 15% with the temperature difference of 500K between 800K and 300K.

  20. Four-body conversion of atomic helium ions

    International Nuclear Information System (INIS)

    de Vries, C.P.; Oskam, H.J.

    1980-01-01

    The conversion of atomic helium ions into molecular ions was studied in pure helium and in helium-neon mixtures containing between 0.1 at. % and 50 at. % neon. The experiments showed that the termolecular conversion reaction, He + +2He → He 2 + +He, is augmented by the four-body conversion reaction He + +3He → products, where the products could include either He 2 + or He 3 + ions. Conversion rate coefficients of (5.7 +- 0.8) x 10 -32 cm 6 sec -1 and (2.6 +- 0.4) x 10 -49 cm 9 sec -1 were found for the termolecular and four-body conversion reactions, respectively. In addition, rate coefficients for the following Ne + conversion reactions were measured: Ne + +He+He → (HeNe) + +He, (2.3 +- 0.1) x 10 -32 cm 6 sec -1 ; Ne + +He+Ne → (HeNe) + +Ne or Ne 2 + +He, (8.0 +- 0.8) x 10 -32 cm 6 sec -1 ; and Ne + +Ne+Ne → Ne 2 + +Ne, (5.1 +- 0.3) x 10 -32 cm 6 sec -1 . All rate coefficients are at a gas temperature of 295 K

  1. Diffusion coefficients of nickel chloride in aqueous solutions of lactose at T = 298.15 K and T = 310.15 K

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Gomes, Joselaine C.S.; Barros, Marisa C.F.; Lobo, Victor M.M.; Esteso, Miguel A.

    2011-01-01

    Binary mutual diffusion coefficients (interdiffusion coefficients) of nickel chloride in water at T = 298.15 K and T = 310.15 K, and at concentrations between (0.000 and 0.100) mol · dm -3 , using a Taylor dispersion method have been measured. These data are discussed on the basis of the Onsager-Fuoss and Pikal models. The equivalent conductance at infinitesimal concentration of the nickel ion in these solutions at T = 310.15 K has been estimated using these results. Through the same technique, ternary mutual diffusion coefficients (D 11 , D 22 , D 12 , and D 21 ) for aqueous solutions containing NiCl 2 and lactose, at T = 298.15 K and T = 310.15 K, and at different carrier concentrations were also measured. These data permit us to have a better understanding of the structure of these systems and the thermodynamic behaviour of NiCl 2 in different media.

  2. Determination of average conversion coefficients between kerma in air and H⁎(10) using primary and secondary X-ray beams and transmitted in the diagnostic radiology energy range

    International Nuclear Information System (INIS)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Costa, Paulo R.

    2016-01-01

    Brazilian regulation establishes 1.14 Sv/Gy as unique conversion coefficient to convert air-kerma into the operational quantity ambient dose equivalent H⁎(10) disregarding its beam quality dependence. The present study computed mean conversion coefficients from primary, secondary and transmitted X-ray beams through barite mortar plates used in shielding of dedicated chest radiographic facilities in order to improve the current assessment of H⁎(10). To compute the mean conversion coefficients, the weighting of conversion coefficients corresponding to monoenergetic beams with the spectrum energy distribution in terms of air-kerma was considered. The maximum difference between the obtained conversion coefficients and the constant value recommended in national regulation is 53.4%. The conclusion based on these results is that a constant coefficient is not adequate for deriving the H⁎(10) from air-kerma measurements. (author)

  3. Diffusion coefficients of nickel chloride in aqueous solutions of lactose at T = 298.15 K and T = 310.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Ana C.F., E-mail: anacfrib@ci.uc.p [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Gomes, Joselaine C.S., E-mail: leidygomes18@hotmail.co [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Barros, Marisa C.F., E-mail: marisa.barros@gmail.co [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Lobo, Victor M.M., E-mail: vlobo@ci.uc.p [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal); Esteso, Miguel A., E-mail: miguel.esteso@uah.e [Departamento de Quimica Fisica, Facultad de Farmacia, Universidad de Alcala, 28871, Alcala de Henares (Madrid) (Spain)

    2011-03-15

    Binary mutual diffusion coefficients (interdiffusion coefficients) of nickel chloride in water at T = 298.15 K and T = 310.15 K, and at concentrations between (0.000 and 0.100) mol {center_dot} dm{sup -3}, using a Taylor dispersion method have been measured. These data are discussed on the basis of the Onsager-Fuoss and Pikal models. The equivalent conductance at infinitesimal concentration of the nickel ion in these solutions at T = 310.15 K has been estimated using these results. Through the same technique, ternary mutual diffusion coefficients (D{sub 11}, D{sub 22}, D{sub 12}, and D{sub 21}) for aqueous solutions containing NiCl{sub 2} and lactose, at T = 298.15 K and T = 310.15 K, and at different carrier concentrations were also measured. These data permit us to have a better understanding of the structure of these systems and the thermodynamic behaviour of NiCl{sub 2} in different media.

  4. Calculation of age-dependent dose conversion coefficients for radionuclides uniformly distributed in air

    International Nuclear Information System (INIS)

    Hung, Tran Van; Satoh, Daiki; Takahashi, Fumiaki; Tsuda, Shuichi; Endo, Akira; Saito, Kimiaki; Yamaguchi, Yasuhiro

    2005-02-01

    Age-dependent dose conversion coefficients for external exposure to photons emitted by radionuclides uniformly distributed in air were calculated. The size of the source region in the calculation was assumed to be effectively semi-infinite in extent. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using MCNP code, a Monte Carlo transport code. The calculations were performed for mono-energetic photon sources of twelve energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10 and 15 years, and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. The calculated effective doses were used to interpolate the conversion coefficients of the effective doses for 160 radionuclides, which are important for dose assessment of nuclear facilities. In the calculation, energies and intensities of emitted photons from radionuclides were taken from DECDC, a recent compilation of decay data for radiation dosimetry developed at JAERI. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ). (author)

  5. Enhanced Oxygen Diffusion Within the Internal Oxidation Zone of Alloy 617 in Controlled Impurity Helium Environments from 1023 K to 1123 K (750 °C to 850 °C)

    Science.gov (United States)

    Gulsoy, Gokce; Was, Gary S.

    2015-04-01

    Alloy 617 was exposed to He-CO-CO2 environments with of either 9 or 1320 at temperatures from 1023 K to 1123 K (750 °C to 850 °C) to determine the oxygen diffusion coefficients within the internal oxidation zone of the alloy. The oxygen diffusion coefficients determined based on both intergranular and transgranular oxidation rates were several orders of magnitude greater than those reported in pure nickel and in nickel-based binary alloys, indicating that the rapid internal aluminum oxidation of Alloy 617 was primarily due to enhanced oxygen diffusion along the incoherent Al2O3-alloy interfaces. The range of activation energy values determined for oxygen diffusion associated with the intergranular aluminum oxidation was from 149.6 to 154.7 kJ/mol, and that associated with the transgranular aluminum oxidation was from 244.7 to 283.5 kJ/mol.

  6. Total internal conversion coefficient of the 260. 9 keV (7/sup +/->3/sup -/) transition in sup(198m)Tl

    Energy Technology Data Exchange (ETDEWEB)

    Venkateswara Rao, N.; Suryanarayana, C.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satynarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1986-02-21

    The 1.87 hours 543.7 keV (7/sup +/) isomeric state in /sup 198/Tl is produced via /sup 197/Au(..cap alpha.., 3n)sup(198m)Tl (Esub(..cap alpha..) = 35 MeV) reaction. The total conversion coefficient of 260.9 keV (7/sup +/ -> 3/sup -/) is determined for the first time by the intensity balance method. The value of ..cap alpha..sub(T)(260.9 keV) is found to be 40.1 +- 8.6 which is in good agreement with the theoretical value of Hager and Seltzer for pure M4 transition. The gamma transition probability of the 260.9 keV (M4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate.

  7. Conversion in the framework of international collaboration. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Akhmetov, T; Vagin, S; Urezchenko, V [eds.

    1997-12-31

    22-26 October 1996 the Republic of Kazakhstan Ministry of Science - Academy of Science, International Science and Technology Center with collaboration of National Nuclear Center of the Republic of Kazakhstan conducted an international workshop {sup C}onversion in the framework of international collaboration{sup .} In the workshop scientists and specialists from different countries participated. 84 reports were presented in this workshop

  8. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  9. The Non-Ergodic Nature of Internal Conversion

    DEFF Research Database (Denmark)

    Kuhlman, Thomas Scheby

    The absorption of light by molecules can induce ultrafast dynamics of coupled electronic and nuclear vibrational motion. The ultrafast nature in many cases rests on the importance of several potential energy surfaces in guiding the nuclear dynamics – a concept of central importance in many aspects...... of chemical reaction dynamics. In this thesis, we focus on the non-ergodic nature of internal conversion, i.e. the concept that the nuclear dynamics only sample a reduced phase space potentially resulting in localization of the dynamics in real space. In essence, this is a consequence of vibrational energy...... cyclopentadienes and dithiane. In the case of the cycloketones, the rate of internal conversion varies by more than an order of magnitude between the molecules. This non-ergodic process was found to primarily involve ring-puckering motion, and the different timescales observed could be rationalized on the basis...

  10. Evaluation of dose conversion coefficients for external exposure using Taiwanese reference man and woman

    International Nuclear Information System (INIS)

    Chang, S.J.; Hung, S.Y.; Liu, Y.L.; Jiang, S.H.; Wu, J.

    2015-01-01

    Reference man has been widely used for external and internal dose evaluation of radiation protection. The parameters of the mathematical model of organs suggested by the International Commission of Radiological Protection (ICRP) are adopted from the average data of Caucasians. However, the organ masses of Asians are significantly different from the data of Caucasians, leading to potentially dosimetric errors. In this study, a total of 40 volunteers whose heights and weights corresponded to the statistical average of Taiwanese adults were recruited. Magnetic resonance imaging was performed, and T2-weighted images were acquired. The Taiwanese reference man and woman were constructed according to the measured organ masses. The dose conversion coefficients (DCFs) for anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT) and left lateral (LLAT) irradiation geometries were simulated. For the Taiwanese reference man, the average differences of the DCFs compared with the results of ICRP-74 were 7.6, 5.1 and 11.1 % for 0.1, 1 and 10 MeV photons irradiated in the AP direction. The maximum difference reached 51.7 % for the testes irradiated by 10 MeV photons. The size of the trunk, the volume and the geometric position of organs can cause a significant impact on the DCFs for external exposure of radiation. The constructed Taiwanese reference man and woman can be used in radiation protection to increase the accuracy of dose evaluation for the Taiwanese population. (authors)

  11. Conversion Intentions of Interns: What Are the Motivating Factors?

    Science.gov (United States)

    Hurst, Jessica L.; Good, Linda K.; Gardner, Phil

    2012-01-01

    Purpose: The purpose of this study is to investigate interns' supervisory support expectations, psychological contract obligations, job satisfaction, perception of advancement opportunities and affective organisational commitment in an attempt to gain a better understanding of how these variables influence interns' conversion intentions.…

  12. Conversion of time-varying Stokes coefficients into mass anomalies at the Earth's surface considering the Earth's oblateness

    Science.gov (United States)

    Ditmar, Pavel

    2018-02-01

    Time-varying Stokes coefficients estimated from GRACE satellite data are routinely converted into mass anomalies at the Earth's surface with the expression proposed for that purpose by Wahr et al. (J Geophys Res 103(B12):30,205-30,229, 1998). However, the results obtained with it represent mass transport at the spherical surface of 6378 km radius. We show that the accuracy of such conversion may be insufficient, especially if the target area is located in a polar region and the signal-to-noise ratio is high. For instance, the peak values of mean linear trends in 2003-2015 estimated over Greenland and Amundsen Sea embayment of West Antarctica may be underestimated in this way by about 15%. As a solution, we propose an updated expression for the conversion of Stokes coefficients into mass anomalies. This expression is based on the assumptions that: (i) mass transport takes place at the reference ellipsoid and (ii) at each point of interest, the ellipsoidal surface is approximated by the sphere with a radius equal to the current radial distance from the Earth's center ("locally spherical approximation"). The updated expression is nearly as simple as the traditionally used one but reduces the inaccuracies of the conversion procedure by an order of magnitude. In addition, we remind the reader that the conversion expressions are defined in spherical (geocentric) coordinates. We demonstrate that the difference between mass anomalies computed in spherical and ellipsoidal (geodetic) coordinates may not be negligible, so that a conversion of geodetic colatitudes into geocentric ones should not be omitted.

  13. Monopole conversion hidden by penetration effect in magnetic dipole transitions

    International Nuclear Information System (INIS)

    Bikit, I.; Anichin, I.; Marinkov, L.

    1977-01-01

    The 191 keV 197 Au nad 340 keV 233 U transitions are investigated and the effect of penetration into the M1-component is accounted for. Theoretical internal conversion coefficients (ICC) and electron parameters to account for the penetration effect have been obtained by interpolating the data of the Hager and Zeltzer tables. The ICC values and ratios are analyzed under the assumption that the 191 keV 197 Au transition has multipolarities M1 + E2 and E 0 +M1. A common overlapping occurs when the nuclear penetration parameter lambda for magnetic dipole transition is lambda = 34.2+-2.2. For the 340 keV 233 U transition the ICC has been found to equal αk=0.69+-0.07, and the relative conversion-line intensities have been determined. It is concluded that the 191 keV 197 Au nad 340 keV 233 U transitions involve an electric monopole component concealed by the penetration effect in the M1-conversion. The matrix elements of the E0-transition have been evaluated

  14. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  15. K and L X-ray emission intensities of some radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Verma, H R; Pal, D [Punjabi Univ., Patiala (India). Dept. of Physics

    1985-01-01

    The K and L x-ray emission intensities per 100 disintegrations have been calculated for some radionuclides using the latest adopted data for gamma-ray intensities, electron capture and internal conversion coefficients for the parent nuclides, fluorescence yield values, Coster-Kronig transition probabilities, average total number of primary L shell vacancies produced in the decay of K shell vacancies and emission rates for various shells and subshells for the daughter nuclei. The results are in good agreement with theoretical and experimental values for the K x-ray intensities. There are no experimental results available to compare with the present calculations for the L x-ray intensities; however, there is a marked discrepancy in the L..cap alpha.. and L..beta.. intensities available on the basis of theoretical estimates.

  16. Proceedings of the international round table on military conversion and science

    International Nuclear Information System (INIS)

    Biggin, S.; Kouzminov, V.

    1994-01-01

    Under the new circumstance after the end of Cold War the International round table on military conversion and science was convened to attempt to clarify the issues concerning science, financing, timing, legislation, personnel brain drain. The majority of presented papers were dealing with the problems of military conversion in countries of Eastern and Central Europe. The role of UNESCO and international cooperation was emphasised

  17. An overview of coefficient alpha and a reliability matrix for estimating adequacy of internal consistency coefficients with psychological research measures.

    Science.gov (United States)

    Ponterotto, Joseph G; Ruckdeschel, Daniel E

    2007-12-01

    The present article addresses issues in reliability assessment that are often neglected in psychological research such as acceptable levels of internal consistency for research purposes, factors affecting the magnitude of coefficient alpha (alpha), and considerations for interpreting alpha within the research context. A new reliability matrix anchored in classical test theory is introduced to help researchers judge adequacy of internal consistency coefficients with research measures. Guidelines and cautions in applying the matrix are provided.

  18. The measurement of friction coefficient down to 1.8 K for LHC Magnets

    CERN Document Server

    Artoos, K; Poncet, Alain; Savary, F; Veness, R J M

    1994-01-01

    The Large Hadron Collider (LHC) proposed for construction at CERN consists of a series of high field superconducting dipole magnet operating at 1.8K. The mechanical structure of these magnets contains many components in close contact. A knowledge of the friction coefficient between these components is required. Indeed, during assembly and cool down of the magnets, prestresses must be transferred to the superconducting coils. During operation, frictional heating may provoke loss of superconductivity. A machine has been built at CERN to measure the coefficient of friction from room temperature down to 1.8K. This paper describes the cryogenic tribometer and the results collected to date.

  19. Design and analysis of Helium Brayton cycle for energy conversion system of RGTT200K

    International Nuclear Information System (INIS)

    Ignatius Djoko Irianto

    2016-01-01

    The helium Brayton cycle for the design of cogeneration energy conversion system for RGTT200K have been analyzed to obtain the higher thermal efficiency and energy utilization factor. The aim of this research is to analyze the potential of the helium Brayton cycle to be implemented in the design of cogeneration energy conversion system of RGTT200K. Three configuration models of cogeneration energy conversion systems have been investigated. In the first configuration model, an intermediate heat exchanger (IHX) is installed in series with the gas turbine, while in the second configuration model, IHX and gas turbines are installed in parallel. The third configuration model is similar to the first configuration, but with two compressors. Performance analysis of Brayton cycle used for cogeneration energy conversion system of RGTT200K has been done by simulating and calculating using CHEMCAD code. The simulation result shows that the three configuration models of cogeneration energy conversion system give the temperature of thermal energy in the secondary side of IHX more than 800 °C at the reactor coolant mass flow rate of 145 kg/s. Nevertheless, the performance parameters, which include thermal efficiency and energy utilization factor (EUF), are different for each configuration model. By comparing the performance parameter in the three configurations of helium Brayton cycle for cogeneration energy conversion systems RGTT200K, it is found that the energy conversion system with a first configuration has the highest thermal efficiency and energy utilization factor (EUF). Thermal efficiency and energy utilization factor for the first configuration of the reactor coolant mass flow rate of 145 kg/s are 35.82 % and 80.63 %. (author)

  20. Internal conversion mediated by specific nuclear motions

    DEFF Research Database (Denmark)

    Klein, Liv Bærenholdt; Sølling, Theis Ivan

    2014-01-01

    the excitation energies, and the excitation in all cases is by a 200 nm photon, the S1 density-of-states in the Franck-Condon region will be high for the more N-alkylated amine. This, according to standard models, should lead to faster internal conversion. The experimental results are in contrast to this...

  1. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    International Nuclear Information System (INIS)

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik; Yasin, Muhammad; Park, Shinyoung; Chang, In Seop; Lee, Eun Yeol

    2015-01-01

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k L a). The feasibility of the new reactor was demonstrated by measuring k L a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k L a value of 102.9 h -1 was obtained

  2. Calculation of effective absorption coefficient for aerosols of internal mixture

    International Nuclear Information System (INIS)

    Xu Bo; Huang Yinbo; Fan Chengyu; Qiao Chunhong

    2012-01-01

    The effective absorption coefficient with time of strong absorbing aerosol made of carbon dusts and water of internal mixture is analyzed, and the influence of different wavelengths and radius ratios on it is discussed. The shorter the wavelength is, the larger the effective absorption coefficient is , and more quickly it increases during 1-100 μs, and the largest increase if 132.65% during 1-100 μs. Different ratios between inner and outer radius have large influence on the effective absorption coefficient. The larger the ratio is, the larger the effective absorption coefficient is, and more quickly it increases during 1-100 μs. The increase of the effective absorption coefficient during 1-100 μs is larger than that during 100-1000 μs, and the largest increase is 138.66% during 1-100 μs. (authors)

  3. Cardiothoracic and Vascular Surgeons Achieve High Rates of K-Award Conversion Into R01 Funding.

    Science.gov (United States)

    Narahari, Adishesh K; Mehaffey, J Hunter; Hawkins, Robert B; Baderdinni, Pranav K; Chandrabhatla, Anirudha S; Tribble, Curtis G; Kron, Irving L; Roeser, Mark E; Walters, Dustin M; Ailawadi, Gorav

    2018-03-14

    Obtaining National Institutes of Health (NIH) R01 funding remains extremely difficult. The utility of career development grants (K awards) for achieving the goal of R01 funding remains debated, particularly for surgeon-scientists. We examined the success rate for cardiothoracic and vascular (CTV) surgeons compared to other specialties in converting K-level grants into R01 equivalents. All K (K08 and K23) grants awarded to surgeons by the NIH between 1992-2017 were identified through NIH RePORTER, an online database combining funding, publications, and patents. Only grants awarded to CTV surgeons were included. Grants active within the past year were excluded. Mann-Whitney U-tests and Chi-squared tests were used to compare groups. A total of 62 K grants awarded to CTV surgeons were identified during this period. Sixteen grants were still active within the last year and excluded from analysis. Twenty-two (48%) of the remaining K awardees successfully transitioned to an R01 or equivalent grant. Awardees with successful conversion published 9 publications per K grant compared to 4 publications for those who did not convert successfully (p=0.01). The median time for successful conversion to an R grant was 5.0 years after the K award start date. Importantly, the 10-year conversion rate to R01 was equal for CTV surgeons compared to other clinician-investigators (52.6% vs 42.5%). CTV surgeons have an equal 10-year conversion rate to first R01 award compared to other clinicians. These data suggest that NIH achieves a good return on investment when funding CTV surgeon-scientists with K-level funding. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Dependence of Seebeck coefficient on a load resistance and energy conversion efficiency in a thermoelectric composite

    International Nuclear Information System (INIS)

    Yamashita, Osamu; Odahara, Hirotaka; Ochi, Takahiro; Satou, Kouji

    2007-01-01

    The thermo-emf ΔV and current ΔI generated by imposing the alternating temperature gradients (ATG) at a period of T and the steady temperature gradient (STG) on a thermoelectric (TE) composite were measured as a function of t, where t is the lapsed time and T was varied from 60 to or ∞ s. The STG and ATG were produced by imposing steadily and alternatively a source voltage V in the range from 1.0 to 4.0 V on two Peltier modules sandwiching a composite. ΔT, ΔV, ΔI and V P oscillate at a period T and their waveforms vary significantly with a change of T, where ΔV and V P are the voltage drops in a load resistance R L and in resistance R P of two modules. The resultant Seebeck coefficient |α| = |ΔV|/ΔT of a composite under the STG was found to be expressed as |α| = |α 0 |(1 - R comp /R T ), where R T is the total resistance of a circuit for measuring the output signals and R comp is the resistance of a composite. The effective generating power ΔW eff has a local maximum at T = 960 s for the p-type composite and at T = 480 s for the n-type one. The maximum energy conversion efficiency η of the p- and n-type composites under the ATG produced by imposing a voltage of 4.0 V at an optimum period were 0.22 and 0.23% at ΔT eff = 50 K, respectively, which are 42 and 43% higher than those at ΔT = 42 K under the STG. These maximum η for a TE composite sandwiched between two Peltier modules, were found to be expressed theoretically in terms of R P , R T , R L , α P and α, where α P and α are the resultant Seebeck coefficients of Peltier modules and a TE composite

  5. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    Science.gov (United States)

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  6. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    International Nuclear Information System (INIS)

    Nogueira, P; Vaz, P; Zankl, M; Schlattl, H

    2011-01-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  7. Determination of the Rate Coefficients of the SO2 plus O plus M yields SO3 plus M Reaction

    Science.gov (United States)

    Hwang, S. M.; Cooke, J. A.; De Witt, K. J.; Rabinowitz, M. J.

    2010-01-01

    Rate coefficients of the title reaction R(sub 31) (SO2 +O+M yields SO3 +M) and R(sub 56) (SO2 + HO2 yields SO3 +OH), important in the conversion of S(IV) to S(VI),were obtained at T =970-1150 K and rho (sub ave) = 16.2 micro mol/cubic cm behind reflected shock waves by a perturbation method. Shock-heated H2/ O2/Ar mixtures were perturbed by adding small amounts of SO2 (1%, 2%, and 3%) and the OH temporal profiles were then measured using laser absorption spectroscopy. Reaction rate coefficients were elucidated by matching the characteristic reaction times acquired from the individual experimental absorption profiles via simultaneous optimization of k(sub 31) and k(sub 56) values in the reaction modeling (for satisfactory matches to the observed characteristic times, it was necessary to take into account R(sub 56)). In the experimental conditions of this study, R(sub 31) is in the low-pressure limit. The rate coefficient expressions fitted using the combined data of this study and the previous experimental results are k(sub 31,0)/[Ar] = 2.9 10(exp 35) T(exp ?6.0) exp(?4780 K/T ) + 6.1 10(exp 24) T(exp ?3.0) exp(?1980 K/T ) cm(sup 6) mol(exp ?2)/ s at T = 300-2500 K; k(sub 56) = 1.36 10(exp 11) exp(?3420 K/T ) cm(exp 3)/mol/s at T = 970-1150 K. Computer simulations of typical aircraft engine environments, using the reaction mechanism with the above k(sub 31,0) and k(sub 56) expressions, gave the maximum S(IV) to S(VI) conversion yield of ca. 3.5% and 2.5% for the constant density and constant pressure flow condition, respectively. Moreover, maximum conversions occur at rather higher temperatures (?1200 K) than that where the maximum k(sub 31,0) value is located (approximately 800 K). This is because the conversion yield is dependent upon not only the k(sup 31,0) and k(sup 56) values (production flux) but also the availability of H, O, and HO2 in the system (consumption flux).

  8. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik [Sogang University, Seoul (Korea, Republic of); Yasin, Muhammad; Park, Shinyoung; Chang, In Seop [Gwangju Institute of Science and Technology (GIST), Gwangju (Korea, Republic of); Lee, Eun Yeol [Kyung Hee University, Yongin (Korea, Republic of)

    2015-06-15

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k{sub L}a). The feasibility of the new reactor was demonstrated by measuring k{sub L}a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k{sub L}a value of 102.9 h{sup -1} was obtained.

  9. Optimization of mass flow rate in RGTT200K coolant purification for Carbon Monoxide conversion process

    International Nuclear Information System (INIS)

    Sumijanto; Sriyono

    2016-01-01

    Carbon monoxide is a species that is difficult to be separated from the reactor coolant helium because it has a relatively small molecular size. So it needs a process of conversion from carbon monoxide to carbondioxide. The rate of conversion of carbon monoxide in the purification system is influenced by several parameters including concentration, temperature and mass flow rate. In this research, optimization of the mass flow rate in coolant purification of RGTT200K for carbon monoxide conversion process was done. Optimization is carried out by using software Super Pro Designer. The rate of reduction of reactant species, the growth rate between the species and the species products in the conversion reactions equilibrium were analyzed to derive the mass flow rate optimization of purification for carbon monoxide conversion process. The purpose of this study is to find the mass flow rate of purification for the preparation of the basic design of the RGTT200K coolant helium purification system. The analysis showed that the helium mass flow rate of 0.6 kg/second resulted in an un optimal conversion process. The optimal conversion process was reached at a mass flow rate of 1.2 kg/second. A flow rate of 3.6 kg/second – 12 kg/second resulted in an ineffective process. For supporting the basic design of the RGTT200K helium purification system, the mass flow rate for carbon monoxide conversion process is suggested to be 1.2 kg/second. (author)

  10. Octanol-air partition coefficients of polybrominated biphenyls.

    Science.gov (United States)

    Hongxia, Zhao; Jingwen, Chen; Xie, Quan; Baocheng, Qu; Xinmiao, Liang

    2009-03-01

    The octanol-air partition coefficients (K(OA)) for PBB15, PBB26, PBB31, PBB49, PBB103 and PBB153 were determined as a function of temperature using a gas chromatographic retention time technique with 1,1,1-trichloro-2,2-bis (4-chlorophenyl) ethane (p,p'-DDT) as a reference substance. The internal energies of phase change from octanol to air (Delta(OA)U) were calculated for the six compounds and were in the range from 74 to 116 kJ mol(-1). Simple regression equations of log K(OA) versus relative retention times (RRTs) on gas chromatography (GC), and log K(OA) versus molecular connectivity indexes (MCI) were obtained, for which the correlation coefficients (r(2)) were greater than 0.985 at 283.15K and 298.15K. Thus the K(OA) values of the remaining PBBs can be predicted by using their RRTs and MCI according to these relationships.

  11. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Wang, Bo

    2008-01-01

    There is a need for an easily accessible method for effective dose estimation in pediatric CT. To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients. A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data. Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10-15 mSv). Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support. (orig.)

  12. Effect of the refraction factor of a plastic fiber shell on the internal reflection coefficient

    International Nuclear Information System (INIS)

    Pkrksypkin, A.I.; Ponomarev, L.I.

    1992-01-01

    Results of pilot studies of the effect of refraction factor of plastic fiber shell on the coefficient of light internal reflection in the fiber are presented. It is pointed, that the shell does not absorb the light, but effects the surface layer of the fiber centre so, that dependence of the coefficient of internal reflection on refraction factor of the shell may be described using Fresnel formulae. It is shown, that coefficient of internal reflection decreases with the increase of refraction factor. Technique to determine volume length of scintillation light absorption in the fiber is suggested

  13. Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry

    International Nuclear Information System (INIS)

    Cavalcante, F.R.; Galeano, D.C.; Carvalho Júnior, A.B.; Hunt, J.

    2014-01-01

    Due to the difficulty in implementing invasive techniques for calculations of dose for some exposure scenarios, computational simulators have been created to represent as realistically as possible the structures of the human body and through radiation transport simulations to obtain conversion coefficients (CCs) to estimate dose. In most published papers simulators are implemented in the standing posture and this may not describe a real scenario of exposure. In this work we developed exposure scenarios in the Visual Monte Carlo (VMC) code using a female simulator in standing and sitting postures. The simulator was irradiated in the antero-posterior (AP) geometry by a plane source of monoenergetic photons with energy from 10 keV to 2 MeV. The conversion coefficients for equivalent dose in terms of air kerma (H T /K air ) were calculated for both scenarios and compared. The results show that the percentage difference of CCs for the organs of the head and thorax was not significant (less than 5%) since the anatomic position of the organs is the same in both postures. The percentage difference is more significant to the ovaries (71% for photon energy of 20 keV), to the bladder (39% at 60 keV) and to the uterus (37% at 100 keV) due to different processes of radiation interactions in the legs of the simulator when its posture is changed. For organs and tissues that are distributed throughout the entire body, such as bone (21% at 100 keV) and muscle (30% at 80 keV) the percentage difference of CCs reflects a reduction of interaction of photons with the legs of the simulator. Therefore, the calculation of conversion coefficients using simulators in the sitting posture is relevant for a more accurate dose estimation in real exposures to radiation. - Highlights: ► Scenarios of external photon exposures were performed in VMC code. ► The FAX simulator was irradiated in sitting and standing postures. ► The irradiation geometry used was the antero-posterior (AP). ► The

  14. Towards the reanalysis of void coefficients measurements at proteus for high conversion light water reactor lattices

    Energy Technology Data Exchange (ETDEWEB)

    Hursin, M.; Koeberl, O.; Perret, G. [Paul Scherrer Institut PSI, 5232 Villigen (Switzerland)

    2012-07-01

    High Conversion Light Water Reactors (HCLWR) allows a better usage of fuel resources thanks to a higher breeding ratio than standard LWR. Their uses together with the current fleet of LWR constitute a fuel cycle thoroughly studied in Japan and the US today. However, one of the issues related to HCLWR is their void reactivity coefficient (VRC), which can be positive. Accurate predictions of void reactivity coefficient in HCLWR conditions and their comparisons with representative experiments are therefore required. In this paper an inter comparison of modern codes and cross-section libraries is performed for a former Benchmark on Void Reactivity Effect in PWRs conducted by the OECD/NEA. It shows an overview of the k-inf values and their associated VRC obtained for infinite lattice calculations with UO{sub 2} and highly enriched MOX fuel cells. The codes MCNPX2.5, TRIPOLI4.4 and CASMO-5 in conjunction with the libraries ENDF/B-VI.8, -VII.0, JEF-2.2 and JEFF-3.1 are used. A non-negligible spread of results for voided conditions is found for the high content MOX fuel. The spread of eigenvalues for the moderated and voided UO{sub 2} fuel are about 200 pcm and 700 pcm, respectively. The standard deviation for the VRCs for the UO{sub 2} fuel is about 0.7% while the one for the MOX fuel is about 13%. This work shows that an appropriate treatment of the unresolved resonance energy range is an important issue for the accurate determination of the void reactivity effect for HCLWR. A comparison to experimental results is needed to resolve the presented discrepancies. (authors)

  15. Ortho-para-H2 conversion by hydrogen exchange: comparison of theory and experiment.

    Science.gov (United States)

    Lique, François; Honvault, Pascal; Faure, Alexandre

    2012-10-21

    We report fully-quantum time-independent calculations of cross sections and rate coefficients for the collisional (de)excitation of H(2) by H. Our calculations are based on the H(3) global potential energy surface of Mielke et al. [J. Chem. Phys. 116, 4142 (2002)]. The reactive hydrogen exchange channels are taken into account. We show that the ortho-para and para-ortho conversion of H(2) are significant processes at temperatures above ~300 K and for the last process we provide the first comparison with available experimental rate coefficients between 300 and 444 K. The good agreement between theory and experiment is a new illustration of our detailed understanding of the simplest chemical reaction. The importance of the ortho-para-H(2) conversion by hydrogen exchange in astrophysics is discussed.

  16. Comparing Hp(3) evaluated from the conversion coefficients from air kerma to personal dose equivalent for eye lens dosimetry calibrated on a new cylindrical PMMA phantom

    Science.gov (United States)

    Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.

    2017-06-01

    Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.

  17. Estimation of saturation activities for activation experiments in CHARM and CSBF using Fluence Conversion Coefficients

    CERN Document Server

    Guerin, Helene Chloe; Iliopoulou, Elpida; CERN. Geneva. HSE Department

    2017-01-01

    As summer student at CERN, I have been working in the Radiation Protection group for 10 weeks. I worked with the \\textsc{Fluka} Monte Carlo simulation code, using Fluence Conversion Coefficients method to perform simulations to estimate the saturation activities for activation experiments in the \\textsc{CSBF} and the \\textsc{Charm} facility in the East Experimental Area. The provided results will be used to plan a Monte Carlo benchmark in the \\textsc{CSBF} during a beam period at the end of August 2017.

  18. FY 2000 Project of international clean energy network using hydrogen conversion (WE-NET)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of the research and development project aimed at construction of the international clean energy network using hydrogen conversion (WE-NET). The projects include 12 tasks; system evaluation for, e.g., optimum scenario for introduction of hydrogen energy; experiments for hydrogen safety; study on the international cooperation for WE-NET; development of power generation technology using a 100kW cogeneration system including hydrogen-firing diesel engine; developmental research on vehicles driven by a hydrogen fuel cell system; developmental research on the basic technologies for PEFC utilizing pure hydrogen; developmental research on a 30Nm{sup 3}/hour hydrogen refueling station for vehicles; developmental research on hydrogen production technology; developmental research on hydrogen transportation and storage technology, e.g., liquid hydrogen pump; research and development of the databases of and processing technology for cryogenic materials exposed to liquid hydrogen; developmental research on hydrogen absorbing alloys for small-scale hydrogen transportation and storage systems; and study on innovative and leading technologies. (NEDO)

  19. Modular approach for conversion to the ion-hybrid wave and α gyroresonance

    International Nuclear Information System (INIS)

    Kaufman, A.N.; Morehead, J.J.; Brizard, A.J.; Tracy, E.R.

    1997-01-01

    Linear conversion of an incoming magnetosonic wave (a.k.a. fast or compressional wave) to an ion-hybrid wave can be considered as a 3-step process in ray phase space. This is demonstrated by casting the cold-fluid model into the Friedland-Kaufman normal form for linear mode conversion. First, the incoming magnetosonic ray (MSR) converts a fraction of its action to an intermediate ion-hybrid ray (IHR), with the transmitted ray proceeding through the conversion layer. The IHR propagates in k-space to a second conversion point, where it converts in turn a fraction of its action into a reflected MSR, with the remainder of the its action constituting the converted IHR. The modular approach gives exact agreement with the more standard Budden formulation for the transmission, reflection and conversion coefficients, but has the important advantage of exposing the intermediate IHR. The existence of the intermediate IHR has important physical consequences as it can resonate with α particles. We estimate the time-integrated damping coefficient between the two conversions and show that ∫γdt is of order -100, thus the IH wave is completely annihilated between conversions and transfers its energy to the α close-quote s. This suggests that proposals to use the IH mode for current drive or DT heating are likely to fail in the presence of fusion α close-quote s. copyright 1997 American Institute of Physics

  20. Reliable measurement of the Seebeck coefficient of organic and inorganic materials between 260 K and 460 K

    Energy Technology Data Exchange (ETDEWEB)

    Beretta, D.; Lanzani, G. [Center for Nano Science and Technology @PoliMi, Istituto Italiano di Tecnologia, via Pascoli 70/3, 20133 Milano (MI) (Italy); Dipartimento di Fisica, P.zza Leonardo da Vinci 32, Politecnico di Milano, 20133 Milano (MI) (Italy); Bruno, P.; Caironi, M., E-mail: mario.caironi@iit.it [Center for Nano Science and Technology @PoliMi, Istituto Italiano di Tecnologia, via Pascoli 70/3, 20133 Milano (MI) (Italy)

    2015-07-15

    A new experimental setup for reliable measurement of the in-plane Seebeck coefficient of organic and inorganic thin films and bulk materials is reported. The system is based on the “Quasi-Static” approach and can measure the thermopower in the range of temperature between 260 K and 460 K. The system has been tested on a pure nickel bulk sample and on a thin film of commercially available PEDOT:PSS deposited by spin coating on glass. Repeatability within 1.5% for the nickel sample is demonstrated, while accuracy in the measurement of both organic and inorganic samples is guaranteed by time interpolation of data and by operating with a temperature difference over the sample of less than 1 K.

  1. Easy measurement of diffusion coefficients of EGFP-tagged plasma membrane proteins using k-space Image Correlation Spectroscopy

    DEFF Research Database (Denmark)

    Christensen, Eva Arnspang; Koffman, Jennifer Skaarup; Marlar, Saw

    2014-01-01

    Lateral diffusion and compartmentalization of plasma membrane proteins are tightly regulated in cells and thus, studying these processes will reveal new insights to plasma membrane protein function and regulation. Recently, k-Space Image Correlation Spectroscopy (kICS)1 was developed to enable...... routine measurements of diffusion coefficients directly from images of fluorescently tagged plasma membrane proteins, that avoided systematic biases introduced by probe photophysics. Although the theoretical basis for the analysis is complex, the method can be implemented by nonexperts using a freely...... to the correlation function yields the diffusion coefficient. This paper provides a step-by-step guide to the image analysis and measurement of diffusion coefficients via kICS. First, a high frame rate image sequence of a fluorescently labeled plasma membrane protein is acquired using a fluorescence microscope Then...

  2. Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulations.

    Science.gov (United States)

    Daures, J; Gouriou, J; Bordy, J M

    2011-03-01

    This work has been performed within the frame of the European Union ORAMED project (Optimisation of RAdiation protection for MEDical staff). The main goal of the project is to improve standards of protection for medical staff for procedures resulting in potentially high exposures and to develop methodologies for better assessing and for reducing, exposures to medical staff. The Work Package WP2 is involved in the development of practical eye-lens dosimetry in interventional radiology. This study is complementary of the part of the ENEA report concerning the calculations with the MCNP-4C code of the conversion factors related to the operational quantity H(p)(3). In this study, a set of energy- and angular-dependent conversion coefficients (H(p)(3)/K(a)), in the newly proposed square cylindrical phantom made of ICRU tissue, have been calculated with the Monte-Carlo code PENELOPE and MCNP5. The H(p)(3) values have been determined in terms of absorbed dose, according to the definition of this quantity, and also with the kerma approximation as formerly reported in ICRU reports. At a low-photon energy (up to 1 MeV), the two results obtained with the two methods are consistent. Nevertheless, large differences are showed at a higher energy. This is mainly due to the lack of electronic equilibrium, especially for small angle incidences. The values of the conversion coefficients obtained with the MCNP-4C code published by ENEA quite agree with the kerma approximation calculations obtained with PENELOPE. We also performed the same calculations with the code MCNP5 with two types of tallies: F6 for kerma approximation and *F8 for estimating the absorbed dose that is, as known, due to secondary electrons. PENELOPE and MCNP5 results agree for the kerma approximation and for the absorbed dose calculation of H(p)(3) and prove that, for photon energies larger than 1 MeV, the transport of the secondary electrons has to be taken into account.

  3. Fluence to absorbed foetal dose conversion coefficients for photons in 50 keV-10 GeV calculated using RPI-P models

    International Nuclear Information System (INIS)

    Taranenko, V.; Xu, X.G.

    2008-01-01

    Radiation protection of pregnant females and the foetus against ionising radiation is of particular importance to radiation protection due to high foetal radiosensitivity. The only available set of foetal conversion coefficients for photons is based on stylised models of simplified anatomy. Using the RPI-P series of pregnant female and foetus models representing 3-, 6- and 9-month gestation, a set of new fluence to absorbed foetal dose conversion coefficients has been calculated. The RPI-P anatomical models were developed using novel 3D geometry modelling techniques. Organ masses were adjusted to agree within 1% with the ICRP reference data for a pregnant female. Monte Carlo dose calculations were carried out using the MCNPX and Penelope codes for external 50 keV-10 GeV photon beams of six standard configurations. The models were voxelised at 3-mm voxel resolution. Conversion coefficients were tabulated for the three gestational periods for the whole foetus and brain. Comparison with previously published data showed deviations up to 120% for the foetal doses at 50 keV. The discrepancy can be primarily ascribed to anatomical differences. Comparison with published data for five major mother organs is also provided for the 3-month model. Since the RPI-P models exhibit a high degree of anatomical realism, the reported dataset is recommended as a reference for radiation protection of the foetus against external photon exposure. (authors)

  4. Ortho-para H₂ conversion by proton exchange at low temperature: an accurate quantum mechanical study.

    Science.gov (United States)

    Honvault, P; Jorfi, M; González-Lezana, T; Faure, A; Pagani, L

    2011-07-08

    We report extensive, accurate fully quantum, time-independent calculations of cross sections at low collision energies, and rate coefficients at low temperatures for the H⁺ + H₂(v = 0, j) → H⁺ + H₂(v = 0, j') reaction. Different transitions are considered, especially the ortho-para conversion (j = 1 → j' = 0) which is of key importance in astrophysics. This conversion process appears to be very efficient and dominant at low temperature, with a rate coefficient of 4.15 × 10⁻¹⁰ cm³ molecule⁻¹ s⁻¹ at 10 K. The quantum mechanical results are also compared with statistical quantum predictions and the reaction is found to be statistical in the low temperature regime (T < 100 K).

  5. Nuclear quadrupole deformations and anisotropic angular correlations between K x rays and gamma rays

    International Nuclear Information System (INIS)

    Khalil, A.E.

    1983-01-01

    Anisotropic angular correlation between gamma rays and the K x rays following the K conversion from nuclei with large static deformations has been studied. A complete theoretical expression for 181 Ta, the second known case of this phenomenon, is presented. This case involves several mixed nuclear transitions which result in 62% of the x rays arising from magnetic dipole internal-conversion processes and 38% arising from electric-quadrupole internal-conversion processes

  6. Gas-phase rate coefficients of the reaction of ozone with four sesquiterpenes at 295 ± 2 K.

    Science.gov (United States)

    Richters, Stefanie; Herrmann, Hartmut; Berndt, Torsten

    2015-05-07

    The rate coefficients of the reaction of ozone with the four atmospherically relevant sesquiterpenes β-caryophyllene, α-humulene, α-cedrene and isolongifolene were investigated at 295 ± 2 K and atmospheric pressure by at least two independent experimental investigations for each reaction. Relative rate experiments were carried out in a flow tube using two different experimental approaches with GC-MS detection (RR 1) and PTR-MS analysis (RR 2) as the analytical techniques. Absolute rate coefficients were determined in a stopped-flow experiment following the ozone depletion by means of UV spectroscopy. The average rate coefficients from the combined investigations representing the mean values of the different experimental methods are (unit: cm(3) molecule(-1) s(-1)): k(O3+β-caryophyllene) = (1.1 ± 0.3) × 10(-14) (methods: RR 1, RR 2, absolute), k(O3+α-humulene) = (1.2 ± 0.3) × 10(-14) (RR 1, RR 2), k(O3+α-cedrene) = (1.7 ± 0.5) × 10(-16) (RR 2, absolute) and k(O3+isolongifolene) = (1.1 ± 0.5) × 10(-17) (RR 2, absolute). The high ozonolysis rate coefficients for β-caryophyllene and α-humulene agree well with the results by Shu and Atkinson (Int. J. Chem. Kinet., 1994, 26) and lead to short atmospheric lifetimes of about two minutes with respect to the ozone reaction. The relatively small rate coefficients for α-cedrene and isolongifolene differ from the available literature values by a factor of about 2.5-6. Possible reasons for the deviations are discussed. Finally, calibrated sesquiterpene FT-IR spectra were recorded for the first time.

  7. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  8. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  9. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  10. Design and Fabrication of a 5-kWe Free-Piston Stirling Power Conversion System

    Science.gov (United States)

    Chapman, Peter A.; Walter, Thomas J.; Brandhorst, Henry W., Jr.

    2008-01-01

    Progress in the design and fabrication of a 5-kWe free-piston Stirling power conversion system is described. A scaled-down version of the successful 12.5-kWe Component Test Power Converter (CTPC) developed under NAS3-25463, this single cylinder prototype incorporates cost effective and readily available materials (steel versus beryllium) and components (a commercial linear alternator). The design consists of a displacer suspended on internally pumped gas bearings and a power piston/alternator supported on flexures. Non-contacting clearance seals are used between internal volumes. Heat to and from the prototype is supplied via pumped liquid loops passing through shell and tube heat exchangers. The control system incorporates several novel ideas such as a pulse start capability and a piston stroke set point control strategy that provides the ability to throttle the engine to match the required output power. It also ensures stable response to various disturbances such as electrical load variations while providing useful data regarding the position of both power piston and displacer. All design and analysis activities are complete and fabrication is underway. Prototype test is planned for summer 2008 at Foster-Miller to characterize the dynamics and steady-state operation of the prototype and determine maximum power output and system efficiency. Further tests will then be performed at Auburn University to determine start-up and shutdown characteristics and assess transient response to temperature and load variations.

  11. Coherent Motion Reveals Non‐Ergodic Nature of Internal Conversion between Excited States

    DEFF Research Database (Denmark)

    Kuhlman, Thomas Scheby; Sølling, Theis I.; Møller, Klaus Braagaard

    2012-01-01

    for smaller molecules. Specifically, we focus on the S2→S1 internal conversion in cyclobutanone, cyclopentanone, and cyclohexanone. By means of time‐resolved mass spectrometry and photoelectron spectroscopy the relative rate of this transition is determined to be 13:2:1. Remarkably, we observe coherent......We found that specific nuclear motion along low‐frequency modes is effective in coupling electronic states and that this motion prevail in some small molecules. Thus, in direct contradiction to what is expected based on the standard models, the internal conversion process can proceed faster...

  12. Testing of the SPEDE conversion electron spectrometer at ISOLDE

    CERN Document Server

    AUTHOR|(CDS)2157167

    2017-04-24

    The aim of this work was to test the performance of the SPEDE detector in the MINIBALL setup at CERN’s ISOLDE laboratory. The main research objective of MINIBALL is to study properties of atomic nuclei employing radioactive ion beams. Radioactive Bi-207 and Hg-191 were used in this experiment. SPEDE detects internal conversion electrons which are created in transitions between states in atomic nucleus. The internal conversion is competing process to more common γ-ray emission. This way it is possible to measure different properties of nuclear structure for example the E0-transitions. The simultaneous γ and electron measurements are possible when SPEDE is used in conjunction with the MINIBALL spectrometer. The GEANT4 simulation results were used to help interpretation of experimental results. As a result, αK/L-ratio was determined for Bi-207 conversion electrons, for the 5^2− -> 1^2− transition αK/L = 3.29±0.06 and for the 13^2+-> 5^2− transition αK/L = 3.11±0.05 were obtained. Also, the partial...

  13. Determining the K coefficient to leaf area index estimations in a tropical dry forest

    Science.gov (United States)

    Magalhães, Sarah Freitas; Calvo-Rodriguez, Sofia; do Espírito Santo, Mário Marcos; Sánchez Azofeifa, Gerardo Arturo

    2018-03-01

    Vegetation indices are useful tools to remotely estimate several important parameters related to ecosystem functioning. However, improving and validating estimations for a wide range of vegetation types are necessary. In this study, we provide a methodology for the estimation of the leaf area index (LAI) in a tropical dry forest (TDF) using the light diffusion through the canopy as a function of the successional stage. For this purpose, we estimated the K coefficient, a parameter that relates the normalized difference vegetation index (NDVI) to LAI, based on photosynthetically active radiation (PAR) and solar radiation. The study was conducted in the Mata Seca State Park, in southeastern Brazil, from 2012 to 2013. We defined four successional stages (very early, early, intermediate, and late) and established one optical phenology tower at one plot of 20 × 20 m per stage. Towers measured the incoming and reflected solar radiation and PAR for NDVI calculation. For each plot, we established 24 points for LAI sampling through hemispherical photographs. Because leaf cover is highly seasonal in TDFs, we determined ΔK (leaf growth phase) and K max (leaf maturity phase). We detected a strong correlation between NDVI and LAI, which is necessary for a reliable determination of the K coefficient. Both NDVI and LAI varied significantly between successional stages, indicating sensitivity to structural changes in forest regeneration. Furthermore, the K values differed between successional stages and correlated significantly with other environmental variables such as air temperature and humidity, fraction of absorbed PAR, and soil moisture. Thus, we established a model based on spectral properties of the vegetation coupled with biophysical characteristics in a TDF that makes possible to estimate LAI from NDVI values. The application of the K coefficient can improve remote estimations of forest primary productivity and gases and energy exchanges between vegetation and atmosphere

  14. Effective dose conversion coefficients for X-ray radiographs of the chest and the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Lima, F.R.A. [Centro regional de Ciencias Nucleares, CRCN/CNEN, Rua Conego Barata, 999, Tamarineira, Recife, PE (Brazil); Kramer, R.; Vieira, J.W.; Khoury, H.J. [Departamento de Energia Nuclear, DEN/UFPE, Cidade Universitaria, Recife, PE (Brazil)]. E-mail: falima@cnen.gov.br

    2004-07-01

    The recently developed MAX (Male Adult voXel) and the FAXht (Female Adult voXel) head and trunk phantoms have been used to calculate organ and tissue equivalent dose conversion coefficients for X-ray radiographs of the chest and the abdomen as a function of source and field parameters, like voltage, filtration, field size, focus-to-skin distance, etc. Based on the equivalent doses to twenty three organs and tissues at risk, the effective dose has been determined and compared with corresponding data for others phantoms. The influence of different radiation transport codes, different tissue compositions and different human anatomies have been investigated separately. (Author)

  15. Effective dose conversion coefficients for X-ray radiographs of the chest and the abdomen

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Vieira, J.W.; Khoury, H.J.

    2004-01-01

    The recently developed MAX (Male Adult voXel) and the FAXht (Female Adult voXel) head and trunk phantoms have been used to calculate organ and tissue equivalent dose conversion coefficients for X-ray radiographs of the chest and the abdomen as a function of source and field parameters, like voltage, filtration, field size, focus-to-skin distance, etc. Based on the equivalent doses to twenty three organs and tissues at risk, the effective dose has been determined and compared with corresponding data for others phantoms. The influence of different radiation transport codes, different tissue compositions and different human anatomies have been investigated separately. (Author)

  16. Total conversion coefficient of the 185 keV (10--7+) transition in sup(182m)Ta

    International Nuclear Information System (INIS)

    Suryanarayana, Ch.; Venkateswara Rao, N.; Raghavaiah, C.V.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.

    1988-01-01

    The total conversion coefficient of the 185 keV (E3) isomeric transition in 182 Ta was measured for the first time using gamma intensity balance method. The experimental αsub(T) was obtained as 3.4 ± 0.2 consistent with the theoretical value (3.272) due to Rosel et al. The E3 transition probability was found to be hindered by a factor of 5.07x10 4 when compared to the single particle estimate. (author). 13 refs

  17. Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

    Science.gov (United States)

    Kessler, W. J.; Carleton, K. L.; Marinelli, W. J.

    1993-01-01

    Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

  18. Radon progeny dose conversion coefficients for Chinese males and females

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K.N. E-mail: peter.yu@city.edu.hk; Cheung, T.T.K.; Haque, A.K.M.M.; Nikezic, D.; Lau, B.M.F.; Vucic, D

    2001-07-01

    The airway dimensions for Caucasian males have been scaled by multiplying by factors 0.95 and 0.88 to give those for Chinese males and females, respectively. Employing the most recent data on physical and biological parameters, the radiation doses to the basal and secretory cells due to {alpha} particles from {sup 218}Po and {sup 214}Po, homogeneously distributed in the mucous layer, have been calculated. The emission of {alpha} particles has been simulated by a Monte Carlo method. For both basal and secretory cells, the dose conversion coefficients (DCCs) for physical conditions of sleep, rest, light and heavy exercise, have been obtained for Chinese males and females for unattached progeny, and for attached progeny of diameters 0.02, 0.15, 0.25, 0.30 and 0.50 {mu}m. For basal cells, the coefficients lie in the range 0.69-6.82 mGy/(J s/m{sup 3}) or 8.7-86 mGy/WLM for unattached progeny and in the range 0.045-1.98 mGy/(J s/m{sup 3}) or 0.57-25 mGy/WLM for attached progeny. The corresponding ranges for Caucasian males are 1.27-8.81 mGy/(J s/m{sup 3}) or 16-111 mGy/WLM{sup -1} and 0.05-2.30 mGy/(J s/m{sup 3}) or 0.64-29 mGy/WLM. For secretory cells, the coefficients lie in the range 0.095-16.82 mGy/(J s/m{sup 3}) (1.2-212 mGy/WLM) for unattached progeny and in the range 0.095-6.67 mGy/(J s/m{sup 3}) (1.2-84 mGy/WLM) for attached progeny. The corresponding ranges for Caucasian males are 0.34-21.51 mGy/(J s/m{sup 3}) (4.3-271 mGy/WLM) and 0.1-7.78 mGy/(J s/m{sup 3}) (1.3-98 mGy/WLM). The overall DCCs calculated for a typical home environment are 0.59 and 0.52 mSv/(J s/m{sup 3}) (7.4 and 6.5 mSv/WLM) for Chinese males and females, respectively, which are 80 and 70% of the value, 0.73 mSv/(J s/m{sup 3}) (9.2 mSv/WLM), for Caucasian males.

  19. Correlation of the Auger electrons direction of movement with the internal electron conversion direction of movement

    International Nuclear Information System (INIS)

    Mitrokhovich, N.F.; Kupryashkin, V.T.; Sidorenko, L.P.

    2013-01-01

    On installation of coincidences of γ-quanta with electrons and with law energy electrons about zero area the spatial correlation of the direction emitting Auger-electrons and electron of internal conversion was investigated at the 152 Eu decay. Auger-electrons were registered on e 0 -electrons of the secondary electron emission (γ e IC e 0 -coincidences). It was established, that Auger-electrons of M-series, as well as electrons 'shake-off' at β-decay and internal conversion, are strongly correlated at the direction of movement with the direction of movement of basic particle (β -particle, conversion electron), moving together mainly in the forward hemisphere. The intensity of correlated M-Auger radiation in range energy 1000 - 1700 eV is equal to intensity of correlated radiation 'shake-off' electron from internal conversion in this range. The assumption, that the presence of spatial correlating Auger-electron and conversion electron caused by cur-rent components of electron-electron interaction of particles in the final state is made

  20. A Quantitative Property-Property Relationship for the Internal Diffusion Coefficients of Organic Compounds in Solid Materials

    DEFF Research Database (Denmark)

    Huang, Lei; Fantke, Peter; Jolliet, Olivier

    2017-01-01

    of chemical-material combinations. This paper develops and evaluates a quantitative property-property relationship (QPPR) to predict diffusion coefficients for a wide range of organic chemicals and materials. We first compiled a training dataset of 1103 measured diffusion coefficients for 158 chemicals in 32......Indoor releases of organic chemicals encapsulated in solid materials are major contributors to human exposures and are directly related to the internal diffusion coefficient in solid materials. Existing correlations to estimate the diffusion coefficient are only valid for a limited number...... consolidated material types. Following a detailed analysis of the temperature influence, we developed a multiple linear regression model to predict diffusion coefficients as a function of chemical molecular weight (MW), temperature, and material type (adjusted R2 of 0.93). The internal validations showed...

  1. Isopiestic determination of the osmotic and activity coefficients of the {yKCl + (1 - y)K2HPO4}(aq) system at T = 298.15 K

    International Nuclear Information System (INIS)

    Popovic, Daniela Z.; Miladinovic, Jelena; Todorovic, Milica D.; Zrilic, Milorad M.; Rard, Joseph A.

    2011-01-01

    Highlights: → Isopiestic measurements were made for {yKCl + (1 - y)K 2 HPO 4 }(aq) at T = 298.15 K. → The resulting osmotic coefficients were represented by three thermodynamic models. → Activity coefficients from Pitzer model with Scatchard mixing terms are recommended. - Abstract: The osmotic coefficients of aqueous mixtures of KCl and K 2 HPO 4 have been measured at T = (298.15 ± 0.01) K by the isopiestic vapor pressure method over the range of ionic strengths from (2.3700 to 11.250) mol . kg -1 using CaCl 2 (aq) as the reference solution. Our new experimental results were modeled with an extended form of Pitzer's ion-interaction model equations, both with the usual mixing terms and with Scatchard's neutral-electrolyte mixing terms, and with the Clegg-Pitzer-Brimblecombe equations based on the mole-fraction-composition scale. There is a dearth of previously published isopiestic data for mixtures containing salts of HPO 4 2- (aq) and, consequently, no previous measurements are available for comparison with the present results. The present study yields Cl - HPO 4 2- mixing parameters for these three models that are needed for modeling the thermodynamic activities of solute components of natural waters and other complex aqueous electrolyte mixtures.

  2. Define of internal recirculation coefficient for biological wastewater treatment in anoxic and aerobic bioreactors

    Science.gov (United States)

    Rossinskyi, Volodymyr

    2018-02-01

    The biological wastewater treatment technologies in anoxic and aerobic bioreactors with recycle of sludge mixture are used for the effective removal of organic compounds from wastewater. The change rate of sludge mixture recirculation between bioreactors leads to a change and redistribution of concentrations of organic compounds in sludge mixture in bioreactors and change hydrodynamic regimes in bioreactors. Determination of the coefficient of internal recirculation of sludge mixture between bioreactors is important for the choice of technological parameters of biological treatment (wastewater treatment duration in anoxic and aerobic bioreactors, flow capacity of recirculation pumps). Determination of the coefficient of internal recirculation of sludge mixture requires integrated consideration of hydrodynamic parameter (flow rate), kinetic parameter (rate of oxidation of organic compounds) and physical-chemical parameter of wastewater (concentration of organic compounds). The conducted numerical experiment from the proposed mathematical equations allowed to obtain analytical dependences of the coefficient of internal recirculation sludge mixture between bioreactors on the concentration of organic compounds in wastewater, the duration of wastewater treatment in bioreactors.

  3. Coefficients of distribution and accumulation of K, Rb, Cs and 137Cs in the intensive poultry breeding cycle

    International Nuclear Information System (INIS)

    Djuric, G.; Ajdacic, N.; Institut za Nuklearne Nauke Boris Kidric, Belgrade

    1984-01-01

    The concentration of K,Rb,Cs and the activity level of Cs-137 in samples from the intensive poultry breeding cycle (feed, meat, eggs), under the condition of chronic alimentary contamination is presented. Concentrations of Cs and Rb were determined by non-destructive neutron activation analysis, concentration of K by atomic absorption flame photometry and activity of Cs-137 by gamma spectrometric analysis. On the basis of these results, coefficients of distribution and accumulation were calculated. The distribution coefficients of the analysed stable isotopes in meat have values close to 1, whereas for various parts of egg these coefficients vary between 0.5 and 1.5. Significant differences in Cs-137 distribution in various parts of egg were established. The values of accumulation coefficients indicate that all analysed elements selectively accumulate in the meat of young birds (broilers), and Cs-137 accumulates in the egg white as well. (orig.)

  4. Tables of the 3-j, 6-j, Fsub(k)-, Asub(k)-, Rsub(k)-, and Asub(kk)-coefficients for angular correlation measurements involving half integer spins up to 15/2 and transitions up to L = 3

    International Nuclear Information System (INIS)

    Gueven, H.H.; Kardon, B.; Seyfarth, H.

    1975-07-01

    Theoretical directional correlation coefficiencts are given as 3-j, 6-j, Fsub(k), Asub(k), Rsub(k) and Asub(kk) coefficients for half integer spins up to 15/2 and for transitions up to L = 3. (WL) [de

  5. Temperature dependence of He(2 3PJ) reactions: Collision-induced mixing and conversion to He2( 3Πg) molecules

    International Nuclear Information System (INIS)

    Zhao, X.; Soletsky, P.A.; Bryan, W.H.; Dunning, F.B.; Walters, G.K.

    1993-01-01

    The rate coefficients for mixing between He(2 3 P J, MJ) levels during collisions with ground-state helium atoms and for conversion of He(2 3 P J ) atoms to He 2 (b 3 Π g ) molecules via three-body reactions in helium gas have been investigated over the temperature range 1.6--300 K. The measured rate coefficients for collisionally induced P-state mixing decrease slowly with decreasing temperature, from (1.8±0.5)x10 -9 cm 3 s -1 at 300 K to (4.5±0.5)x10 -10 cm 3 s -1 at 4.2 K. The rate coefficients for the production of He 2 (b 3 Π g ) molecules via three-body reactions are observed to increase with decreasing temperature and are described by the relation k P congruent(2.5+267T -1 )x10 -32 cm 6 s -1 . This behavior, which is very different from that noted in earlier studies of the conversion of He(2 3 S 1 ) atoms to He 2 (a 3 Σ u + ) molecules through three-body reactions, suggests that the reaction is not thermally activated

  6. Engineering of beam direct conversion for a 120-kV, 1-MW ion beam

    International Nuclear Information System (INIS)

    Barr, W.L.; Doggett, J.N.; Hamilton, G.W.; Kinney, J.D.; Moir, R.W.

    1977-01-01

    Practical systems for beam direct conversion are required to recover the energy from ion beams at high efficiency and at very high beam power densities in the environment of a high-power, neutral-injection system. Such an experiment is now in progress using a 120-kV beam with a maximum total current of 20 A. After neutralization, the H + component to be recovered will have a power of approximately 1MW. A system testing these concepts has been designed and tested at 15 kV, 2 kW in preparation for the full-power tests. The engineering problems involved in the full-power tests affect electron suppression, gas pumping, voltage holding, diagnostics, and measurement conditions. Planning for future experiments at higher power includes the use of cryopumping and electron suppression by a magnetic field rather than by an electrostatic field. Beam direct conversion for large fusion experiments and reactors will save millions of dollars in the cost of power supplies and electricity and will dispose of the charged beam under conditions that may mot be possible by other techniques

  7. Engineering of beam direct conversion for a 120-kV, 1-MW ion beam

    International Nuclear Information System (INIS)

    Barr, W.L.; Doggett, J.N.; Hamilton, G.W.; Kinney, J.D.; Moir, R.W.

    1977-01-01

    Practical systems for beam direct conversion are required to recover the energy from ion beams at high efficiency and at very high beam power densities in the environment of a high-power, neutral-injection system. Such an experiment is now in progress using a 120-kV beam with a maximum total current of 20 A. After neutralization, the H + component to be recovered will have a power of approximately 1 MW. A system testing these concepts has been designed and tested at 15 kV, 2 kW in preparation for the full-power tests. The engineering problems involved in the full-power tests affect electron suppression, gas pumping, voltage holding, diagnostics, and measurement conditions. Planning for future experiments at higher power includes the use of cryopumping and electron suppression by a magnetic field rather than by an electrostatic field. Beam direct conversion for large fusion experiments and reactors will save millions of dollars in the cost of power supplies and electricity and will dispose of the charged beam under conditions that may not be possible by other techniques

  8. Foetal dose conversion coefficients for ICRP-compliant pregnant models from idealised proton exposures

    International Nuclear Information System (INIS)

    Taranenko, V.; Xu, X. G.

    2009-01-01

    Protection of pregnant women and their foetus against external proton irradiations poses a unique challenge. Assessment of foetal dose due to external protons in galactic cosmic rays and as secondaries generated in aircraft walls is especially important during high-altitude flights. This paper reports a set of fluence to absorbed dose conversion coefficients for the foetus and its brain for external monoenergetic proton beams of six standard configurations (the antero-posterior, the postero-anterior, the right lateral, the left lateral, the rotational and the isotropic). The pregnant female anatomical definitions at each of the three gestational periods (3, 6 and 9 months) are based on newly developed RPI-P series of models whose organ masses were matched within 1% with the International Commission on Radiological Protection reference values. Proton interactions and the transport of secondary particles were carefully simulated using the Monte Carlo N-Particle extended code (MCNPX) and the phantoms consisting of several million voxels at 3 mm resolution. When choosing the physics models in the MCNPX, it was found that the advanced Cascade-Exciton intranuclear cascade model showed a maximum of 9% foetal dose increase compared with the default model combination at intermediate energies below 5 GeV. Foetal dose results from this study are tabulated and compared with previously published data that were based on simplified anatomy. The comparison showed a strong dependence upon the source geometry, energy and gestation period: The dose differences are typically less than 20% for all sources except ISO where systematically 40-80% of higher doses were observed. Below 200 MeV, a larger discrepancy in dose was found due to the Bragg peak shift caused by different anatomy. The tabulated foetal doses represent the latest and most detailed study to date offering a useful set of data to improve radiation protection dosimetry against external protons. (authors)

  9. U.K. policy responses to international influences - nuclear power

    International Nuclear Information System (INIS)

    Jones, P.M.S.

    1978-01-01

    An account is given of U.K. participation in international discussions directed towards the safe development and application of nuclear power. Particular attention is given to the International Fuel Cycle Evaluation (INFCE), which is stated to be looking at the whole question of proliferation and the merits and disadvantages of a range of alternative fuel cycles and nuclear power strategies. A summary is also given of U.K. participation in work on radiological protection (through the I.C.R.P.) and radioactive waste disposal. International cooperation in research and development is mentioned. Public involvement in policy making is also discussed briefly. (U.K.)

  10. Fluence-to-effective dose conversion coefficients from a Saudi population based phantom for monoenergetic photon beams from 10 keV to 20 MeV

    International Nuclear Information System (INIS)

    Ma, Andy K; Hussein, Mohammed Adel; Altaher, Khalid Mohammed; Farid, Khalid Yousif; Amer, Mamun; Aldhafery, Bander Fuhaid; Alghamdi, Ali A

    2015-01-01

    Fluence-to-dose conversion coefficients are important quantities for radiation protection, derived from Monte Carlo simulations of the radiation particles through a stylised phantom or voxel based phantoms. The voxel phantoms have been developed for many ethnic groups for their accurate reflection of the anatomy. In this study, we used the Monte Carlo code MCNPX to calculate the photon fluence-to-effective dose conversion coefficients with a voxel phantom based on the Saudi Arabian male population. Six irradiation geometries, anterior–posterior (AP), posterior–anterior (PA), left lateral (LLAT), right lateral (RLAT), rotational (ROT) and isotropic (ISO) were simulated for monoenergetic photon beams from 10 keV to 20 MeV. We compared the coefficients with the reference values in ICRP Publication 116. The coefficients in the AP and PA geometries match the reference values to 9% and 12% on average as measured by root mean square while those in the LLAT, RLAT ROT and ISO geometries differ, mostly below, from the reference by 23, 22, 15 and 16%, respectively. The torso of the Saudi phantom is wider than the ICRP reference male phantom and likely to cause more attenuation to the lateral beam. The ICRP reference coefficients serve well for the Saudi male population as conservative estimations for the purpose of radiation protection. (paper)

  11. Determination and importance of temperature dependence of retention coefficient (RPHPLC) in QSAR model of nitrazepams' partition coefficient in bile acid micelles.

    Science.gov (United States)

    Posa, Mihalj; Pilipović, Ana; Lalić, Mladena; Popović, Jovan

    2011-02-15

    Linear dependence between temperature (t) and retention coefficient (k, reversed phase HPLC) of bile acids is obtained. Parameters (a, intercept and b, slope) of the linear function k=f(t) highly correlate with bile acids' structures. Investigated bile acids form linear congeneric groups on a principal component (calculated from k=f(t)) score plot that are in accordance with conformations of the hydroxyl and oxo groups in a bile acid steroid skeleton. Partition coefficient (K(p)) of nitrazepam in bile acids' micelles is investigated. Nitrazepam molecules incorporated in micelles show modified bioavailability (depo effect, higher permeability, etc.). Using multiple linear regression method QSAR models of nitrazepams' partition coefficient, K(p) are derived on the temperatures of 25°C and 37°C. For deriving linear regression models on both temperatures experimentally obtained lipophilicity parameters are included (PC1 from data k=f(t)) and in silico descriptors of the shape of a molecule while on the higher temperature molecular polarisation is introduced. This indicates the fact that the incorporation mechanism of nitrazepam in BA micelles changes on the higher temperatures. QSAR models are derived using partial least squares method as well. Experimental parameters k=f(t) are shown to be significant predictive variables. Both QSAR models are validated using cross validation and internal validation method. PLS models have slightly higher predictive capability than MLR models. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code

    CERN Document Server

    Paganini, S

    2005-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from Galactic cosmic radiation. Crews of future high-speed commercial flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the male adult voxels phantom MAX, developed in the Nuclear Energy Department of Pernambuco Federal University in Brazil, has been coupled with the Monte Carlo simulation code GEANT4. This toolkit, distributed and upgraded from the international scientific community of CERN/Switzerland, simulates thermal to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude. In this research calculations of conversion coefficients from fluence to effective dose are performed for neutrons of energies from 100 MeV ...

  13. Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens

    International Nuclear Information System (INIS)

    Ferrari, P.; Gualdrini, G.; Fantuzzi, E.; Tanner, R.

    2014-01-01

    The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating H p (3) for neutron realistic workplace spectra is treated, employing the recently published H p (3)/Φ conversion coefficients with the aim of establishing a workplace-dependent relationship between H p (10) and H p (3). The results demonstrate that, whilst the two quantities can differ by less than 10 %, in general, H p (10) cannot be considered a conservative estimate of H p (3). The present study was conducted to find out whether it is possible to derive H p (3) from H p (10) measurements/determinations in neutron workplace fields using the relationship that can be established between the conversion coefficients H p (3)/Φ and H p (10)/Φ evaluated for monoenergetic neutron beams. Several real cases, taken from the IAEA neutron source compendium, were investigated and, in general, it can be conclude that H p (10) is seldom a conservative estimate of H p (3) (only at 0 deg. and in one case, among the treated spectra, H p (10)/Φ is higher than H p (3)/Φ). Indeed, care should be taken if one tries to derive directly such a correction factor from tabulations of neutron monoenergetic plots of conversion coefficients, on the basis of the mean energy, because in case of really degraded spectra (as in the heavy shielded situation) the mean energy, as expected, could be a too rough a parameter. However, in general, for 0 deg., antero-posterior irradiation condition, which is expected to be a quite common working condition, H p (10) underestimation is of the order of 10 % thus, at least, a correction factor of 1.1 should be applied to H p (10) in order to estimate the 'corresponding' H p (3). For irradiation conditions far from the normal incidence for which the underestimation can be as high as 60

  14. Deuterons at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2011-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to deuterons ( 2 H + ) in the energy range 10 MeV -1 TeV (0.01-1000 GeV). Coefficients were calculated using the Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of the effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Coefficients for the equivalent and effective dose incorporated a radiation weighting factor of 2. At 15 of 19 energies for which coefficients for the effective dose were calculated, coefficients based on ICRP 1990 and 2007 recommendations differed by < 3 %. The greatest difference, 47 %, occurred at 30 MeV. (authors)

  15. [Conversion disorder in an internal medicine department: A series of 37 cases].

    Science.gov (United States)

    Régny, P; Cathébras, P

    2016-04-01

    To describe the clinical characteristics of a series of patients presenting conversion disorder in a general internal medicine ward and outpatient clinic, the arguments retained by the physicians in favour of the diagnosis, the somatic and psychiatric co-morbidities, the management and the outcome of the disorder. We report the study of 37 patients diagnosed with conversion disorder in an internal medicine department of a French university hospital over a period of 14 years. We retrospectively reviewed the charts of the patients and contacted their primary care physicians to obtain follow-up data. No structured instrument was used for the diagnosis of conversion disorder or for the assessment of psychiatric comorbidities. As expected, patients were mostly young females, although a great variety of age, gender, and socio-cultural background was observed. Motor symptoms predominated (62%). A relevant psychogenic factor was explicitly mentioned in only 43% of the cases. In many cases, organic disease was also present, and an organic cause for the symptom initially considered as conversion was suspected in 3 cases. Depressive and anxious disorders were present respectively in 38% and 35% of cases. A pain complaint was associated in half of the cases. Among patients for whom follow-up data is available, conversion symptoms persisted or recurred in 70% of cases and were associated with a poor quality of life. This case series confirms that the DSM-IV-TR criterion of "psychogenicity" (later abandoned in DSM-5) is highly problematic in clinical practice. It suggests a close relationship between conversion disorder and unexplained chronic pain. Copyright © 2015 L’Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.

  16. Resonance internal conversion as a way of accelerating nuclear processes

    International Nuclear Information System (INIS)

    Karpeshin, F.F.

    2006-01-01

    Theory of resonance conversion is presented. Being a natural extension of the traditional internal conversion into the subthreshold area, resonance conversion in a number of cases strongly affects the nuclear processes. Moreover, concentrating the transition strength on the narrow bands corresponding to the spectral atomic lines, it offers a unique tool capable of accelerating nuclear decay rates. Furthermore, along with the conventional nonradiative process of nuclear excitation through NEET and its reverse, TEEN, resonance conversion offers an appropriate mathematics for consideration of a number of cross-invariant processes involving both nuclei and electrons: excitation and deexcitation of the nuclei by hyperfine magnetic field, nuclear spin mixing, hyperfine interaction and magnetic anomalies in the atomic spectra, collisional nuclear excitation via ionization of the shells in the muon decay in the orbit, etc. The mechanisms of the optical pumping of the isomers are also considered, as well as triggering their energy in the resonance field of a laser. The effect is especially high in the hydrogen-like heavy ions due to practical absence of any damping of the resonance. The theory is also generalized to the case of the discrete Auger transitions [ru

  17. First-principles method for calculating the rate constants of internal-conversion and intersystem-crossing transitions.

    Science.gov (United States)

    Valiev, R R; Cherepanov, V N; Baryshnikov, G V; Sundholm, D

    2018-02-28

    A method for calculating the rate constants for internal-conversion (k IC ) and intersystem-crossing (k ISC ) processes within the adiabatic and Franck-Condon (FC) approximations is proposed. The applicability of the method is demonstrated by calculation of k IC and k ISC for a set of organic and organometallic compounds with experimentally known spectroscopic properties. The studied molecules were pyrromethene-567 dye, psoralene, hetero[8]circulenes, free-base porphyrin, naphthalene, and larger polyacenes. We also studied fac-Alq 3 and fac-Ir(ppy) 3 , which are important molecules in organic light emitting diodes (OLEDs). The excitation energies were calculated at the multi-configuration quasi-degenerate second-order perturbation theory (XMC-QDPT2) level, which is found to yield excitation energies in good agreement with experimental data. Spin-orbit coupling matrix elements, non-adiabatic coupling matrix elements, Huang-Rhys factors, and vibrational energies were calculated at the time-dependent density functional theory (TDDFT) and complete active space self-consistent field (CASSCF) levels. The computed fluorescence quantum yields for the pyrromethene-567 dye, psoralene, hetero[8]circulenes, fac-Alq 3 and fac-Ir(ppy) 3 agree well with experimental data, whereas for the free-base porphyrin, naphthalene, and the polyacenes, the obtained quantum yields significantly differ from the experimental values, because the FC and adiabatic approximations are not accurate for these molecules.

  18. Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber

    Science.gov (United States)

    Peng, Dong-qing; Zhu, Li-li; Li, Zhi-fang; Li, Hui

    2017-09-01

    Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.

  19. Post-recombination early Universe cooling by translation-internal inter-conversion: The role of minor constituents.

    Science.gov (United States)

    McCaffery, Anthony J

    2015-09-14

    Little is known of the mechanism by which H and H2, the principal constituents of the post-re-combination early Universe, cooled sufficiently to permit cluster formation, nucleosynthesis, and, eventually, the formation of structured objects. Radiative decay primarily cools the internal modes of H2, as Δj = - 2 jumps accompany quadrupolar emission. This, however, would be a self-limiting mechanism. In this work, a translational energy cooling mechanism based on collision-induced, translation-to-internal mode conversion, is extended, following an earlier study [A. J. McCaffery and R. J. Marsh, J. Chem. Phys. 139, 234310 (2013)] of ensembles comprising H2 in a H atom bath gas. Here, the possible influence of minor species, such as HD, on this cooling mechanism is investigated. Results suggest that the influence of HD is small but not insignificant. Conversion is very rapid and an overall translation-to-internal energy conversion efficiency of some 5% could be expected. This finding may be of use in the further development of models of this complex phase of early Universe evolution. An unexpected finding in this study was that H2 + HD ensembles are capable of very rapid translation-to-internal conversion with efficiencies of >40% and relaxation rates that appear to be relatively slow. This may have potential as an energy storage mechanism.

  20. Reproducibility of The Random Incidence Absorption Coefficient Converted From the Sabine Absorption Coefficient

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Chang, Ji-ho

    2015-01-01

    largely depending on the test room. Several conversion methods for porous absorbers from the Sabine absorption coefficient to the random incidence absorption coefficient were suggested by considering the finite size of a test specimen and non-uniformly incident energy onto the specimen, which turned out...... resistivity optimization outperforms the surface impedance optimization in terms of the reproducibility....

  1. Calculation of conversion coefficients of dose of a computational anthropomorphic simulator sit exposed to a plane source

    International Nuclear Information System (INIS)

    Santos, William S.; Carvalho Junior, Alberico B. de; Pereira, Ariana J.S.; Santos, Marcos S.; Maia, Ana F.

    2011-01-01

    In this paper conversion coefficients (CCs) of equivalent dose and effective in terms of kerma in the air were calculated suggested by the ICRP 74. These dose coefficients were calculated considering a plane radiation source and monoenergetic for a spectrum of energy varying from 10 keV to 2 MeV. The CCs were obtained for four geometries of irradiation, anterior-posterior, posterior-anterior, lateral right side and lateral left side. It was used the radiation transport code Visual Monte Carlo (VMC), and a anthropomorphic simulator of sit female voxel. The observed differences in the found values for the CCs at the four irradiation sceneries are direct results of the body organs disposition, and the distance of these organs to the irradiation source. The obtained CCs will be used for estimative more precise of dose in situations that the exposed individual be sit, as the normally the CCs available in the literature were calculated by using simulators always lying or on their feet

  2. Activity coefficients in (hydrogen chloride+holmium chloride) (aq) from T=(278.15 to 328.15) K

    International Nuclear Information System (INIS)

    Roy, Rabindra N.; Roy, Lakshmi N.; Tabor, Bennett J.; Richards, Sarah J.; Cummins, Mason P.; Himes, Curtis A.; Gibbs, Stephanie N.; Christiansen, Edward B.

    2005-01-01

    Activity coefficients of HCl in (hydrogen chloride+holmium chloride) (aq) have been calculated from the observed e.m.f.s using the Nernst equation. The temperatures ranged from (278.15 to 328.15) K at 5 K intervals and at constant total ionic strengths of (0.01, 0.025, 0.05, 0.1, 0.25, 0.5, 1.0, and 1.5) mol.kg -1 . Electromotive-force measurements were made on the cell without liquid junction of the type:Pt vertical bar H 2 (g,p=101.325kPa) vertical bar HCl(m A ),HoCl 3 (m B ) vertical bar AgCl(s), vertical bar Ag(s) The results of the activity coefficients of HCl for this mixed electrolyte mixture have been interpreted in terms of the simpler Harned's equations and the ion-interaction model of Pitzer. Results show that the quadratic term is sufficient for the full range of Y B (the ionic strength fraction of the salt) to 0.9 at all the ionic strengths studied. The Pitzer's mixing parameters S θH,Ho and Ψ H,Ho,Cl (including higher order electrostatic effects) and θ H,Ho and Ψ H,Ho,Cl (excluding higher order electrostatic effects) have been determined. These values at T=298.15 K are: S θH , Ho =0.115, Ψ H,Ho,Cl =-.071; and θ H,Ho =-.663, Ψ H,Ho,Cl =0.165. The parameters obtained in this study reproduce the activity coefficients of HCl in the mixtures within 0.015 over the entire range of ionic strengths and within 0.009 for I>=0.05 mol.kg -1 over the entire temperature range

  3. Ouabain-induced internalization and lysosomal degradation of the Na+/K+-ATPase.

    Science.gov (United States)

    Cherniavsky-Lev, Marina; Golani, Ofra; Karlish, Steven J D; Garty, Haim

    2014-01-10

    Internalization of the Na(+)/K(+)-ATPase (the Na(+) pump) has been studied in the human lung carcinoma cell line H1299 that expresses YFP-tagged α1 from its normal genomic localization. Both real-time imaging and surface biotinylation have demonstrated internalization of α1 induced by ≥100 nm ouabain which occurs in a time scale of hours. Unlike previous studies in other systems, the ouabain-induced internalization was insensitive to Src or PI3K inhibitors. Accumulation of α1 in the cells could be augmented by inhibition of lysosomal degradation but not by proteosomal inhibitors. In agreement, the internalized α1 could be colocalized with the lysosomal marker LAMP1 but not with Golgi or nuclear markers. In principle, internalization could be triggered by a conformational change of the ouabain-bound Na(+)/K(+)-ATPase molecule or more generally by the disruption of cation homeostasis (Na(+), K(+), Ca(2+)) due to the partial inhibition of active Na(+) and K(+) transport. Overexpression of ouabain-insensitive rat α1 failed to inhibit internalization of human α1 expressed in the same cells. In addition, incubating cells in a K(+)-free medium did not induce internalization of the pump or affect the response to ouabain. Thus, internalization is not the result of changes in the cellular cation balance but is likely to be triggered by a conformational change of the protein itself. In physiological conditions, internalization may serve to eliminate pumps that have been blocked by endogenous ouabain or other cardiac glycosides. This mechanism may be required due to the very slow dissociation of the ouabain·Na(+)/K(+)-ATPase complex.

  4. Internal conversion of the (13/2+→5/2-) isomeric transition in 199Hg

    International Nuclear Information System (INIS)

    Radha Krishna, K.; Chandrasekhar Rao, M.V.S.; Sree Krishna Murty, G.; Venkateswara Rao, N.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.; Iyer, M.R.; Sahasrabhude, S.G.

    1990-01-01

    The total conversion coefficient of the M4 transition (374 KeV) in the decay of the 13/2 + isomeric state to 5/2 - state in 199 Hg measured using the relative gamma intensity method α T is determined to be 6.34 ± 0.29 in agreement with the theory due to Rosel et al. (author). 1 tab., 3 figs., 11 refs

  5. Direct Determination of the Rate Coefficient for the Reaction of OH Radicals with Monoethanol Amine (MEA) from 296 to 510 K.

    Science.gov (United States)

    Onel, L; Blitz, M A; Seakins, P W

    2012-04-05

    Monoethanol amine (H2NCH2CH2OH, MEA) has been proposed for large-scale use in carbon capture and storage. We present the first absolute, temperature-dependent determination of the rate coefficient for the reaction of OH with MEA using laser flash photolysis for OH generation, monitoring OH removal by laser-induced fluorescence. The room-temperature rate coefficient is determined to be (7.61 ± 0.76) × 10(-11) cm(3) molecule(-1) s(-1), and the rate coefficient decreases by about 40% by 510 K. The temperature dependence of the rate coefficient is given by k1= (7.73 ± 0.24) × 10(-11)(T/295)(-(0.79±0.11)) cm(3) molecule(-1) s(-1). The high rate coefficient shows that gas-phase processing in the atmosphere will be competitive with uptake onto aerosols.

  6. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams; Determinacao experimental dos coeficientes de conversao de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Paulo Henrique Goncalves

    2008-07-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm{sup 3} Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with {sup 133} Ba, {sup 241} Am and {sup 57} Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of

  7. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  8. Tritons at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose, and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2010-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to tritons ( 3 H + ) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Coefficients were calculated using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and calculation of gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 3%. The greatest difference, 43%, occurred at 30 MeV. Published by Oxford Univ. Press on behalf of the US Government 2010. (authors)

  9. Measurement and modeling of osmotic coefficients of binary mixtures (alcohol + 1,3-dimethylpyridinium methylsulfate) at T = 323.15 K

    International Nuclear Information System (INIS)

    Gomez, Elena; Calvar, Noelia; Dominguez, Angeles; Macedo, Eugenia A.

    2011-01-01

    Research highlights: → The osmotic coefficients of binary mixtures (alcohol + ionic liquid) were determined. → The measurements were carried out with a vapor pressure osmometer at 323.15 K. → The Pitzer-Archer, and the MNRTL models were used to correlate the experimental data. → Mean molal activity coefficients and excess Gibbs free energies were calculated. - Abstract: Measurement of osmotic coefficients of binary mixtures containing several primary and secondary alcohols (1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol) and the pyridinium-based ionic liquid 1,3-dimethylpyridinium methylsulfate were performed at T = 323.15 K using the vapor pressure osmometry technique, and from experimental data, vapor pressure, and activity coefficients were determined. The extended Pitzer model modified by Archer, and the NRTL model modified by Jaretun and Aly (MNRTL) were used to correlate the experimental osmotic coefficients, obtaining standard deviations lower than 0.017 and 0.054, respectively. From the parameters obtained with the extended Pitzer model modified by Archer, the mean molal activity coefficients and the excess Gibbs free energy for the studied binary mixtures were calculated. The effect of the cation is studied comparing the experimental results with those obtained for the ionic liquid 1,3-dimethylimidazolium methylsulfate.

  10. Determination of conversion factors of kerma and fluence to ambient dose equivalent for X-rays generated between 50 kV{sub p} to 125 kV{sub p}; Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios-X gerados no intervalo de 50 kV{sub p} a 125 kV{sub p}

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Maria do Socorro

    1997-12-31

    The ambient dose equivalent was determined experimentally on the interval of energy of X ray applied in diagnostic radiology. A PMMA sphere was used to simulate the trunk human (phantom), based on the definition of the report ICRU 39. The absorbed dose in different positions in the phantom was determined using LiF-TLD 100. The X ray spectra were measured with a high-purity germanium detector (HP Ge). It was also determined the HVL and the effective energy in this energy range. The conversion coefficient of the K{sub air} and {Phi} to H{sup *}(d) were determined to 10, 50 and 60 mm deep in the PMMA sphere. The obtained values were compared with data of the literature. The maximum uncertainty obtained for the coefficients was 7.2%. All parameters were also determined to the X ray quality of the incident and transmitted beam by the patient, according to the recommendation of the standard DIN 6872. The conversion factor was calculated for those situations where the X-ray beam is transmitted by a layer and Pb and it is necessary to estimate the effective dose, as in the case of shielding project of radiology diagnosis room. (author) 51 refs., 35 figs., 15 tabs.

  11. Determination of conversion factors of kerma and fluence to ambient dose equivalent for X-rays generated between 50 kV{sub p} to 125 kV{sub p}; Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios-X gerados no intervalo de 50 kV{sub p} a 125 kV{sub p}

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Maria do Socorro

    1998-12-31

    The ambient dose equivalent was determined experimentally on the interval of energy of X ray applied in diagnostic radiology. A PMMA sphere was used to simulate the trunk human (phantom), based on the definition of the report ICRU 39. The absorbed dose in different positions in the phantom was determined using LiF-TLD 100. The X ray spectra were measured with a high-purity germanium detector (HP Ge). It was also determined the HVL and the effective energy in this energy range. The conversion coefficient of the K{sub air} and {Phi} to H{sup *}(d) were determined to 10, 50 and 60 mm deep in the PMMA sphere. The obtained values were compared with data of the literature. The maximum uncertainty obtained for the coefficients was 7.2%. All parameters were also determined to the X ray quality of the incident and transmitted beam by the patient, according to the recommendation of the standard DIN 6872. The conversion factor was calculated for those situations where the X-ray beam is transmitted by a layer and Pb and it is necessary to estimate the effective dose, as in the case of shielding project of radiology diagnosis room. (author) 51 refs., 35 figs., 15 tabs.

  12. Activity coefficients of CaCl2 in (maltose + water) and (lactose + water) mixtures at 298.15 K

    International Nuclear Information System (INIS)

    Zhuo Kelei; Liu Hongxun; Zhang Honghao; Liu Yaohui; Wang Jianji

    2008-01-01

    Activity coefficients of CaCl 2 in disaccharide {(maltose, lactose) + water} mixtures at 298.15 K were determined by cell potentials. The molalities of CaCl 2 ranged from about 0.01 mol . kg -1 to 0.20 mol . kg -1 , the mass fractions of maltose from 0.05 to 0.25, and those of lactose from 0.025 to 0.125. The cell potentials were analyzed by using the Debye-Hueckel extended equation and the Pitzer equation. The activity coefficients obtained from the two theoretical models are in good agreement with each other. Gibbs free energy interaction parameters (g ES ) and salting constants (k S ) were also obtained. These were discussed in terms of the stereo-chemistry of saccharide molecules and the structural interaction model

  13. On k-summability of formal solutions for certain partial differential operators with polynomial coefficients

    Directory of Open Access Journals (Sweden)

    Kunio Ichinobe

    2015-01-01

    Full Text Available We study the \\(k\\-summability of divergent formal solutions for the Cauchy problem of certain linear partial differential operators with coefficients which are polynomial in \\(t\\. We employ the method of successive approximation in order to construct the formal solutions and to obtain the properties of analytic continuation of the solutions of convolution equations and their exponential growth estimates.

  14. Coefficients calculations of conversion of cancer risk for occupational exposure using Monte Carlo simulations in cardiac procedures of interventionist radiology

    International Nuclear Information System (INIS)

    Santos, William S.; Neves, Lucio P.; Perini, Ana P.; Caldas, Linda V.E.; Maia, Ana F.

    2014-01-01

    Cardiac procedures are among the most common procedures in interventional radiology (IR), and can lead to high medical and occupational exposures, as in most cases are procedures complex and long lasting. In this work, conversion coefficients (CC) for the risk of cancer, normalized by kerma area product (KAP) to the patient, cardiologist and nurse were calculated using Monte Carlo simulation. The patient and the cardiologist were represented by anthropomorphic simulators MESH, and the nurse by anthropomorphic phantom FASH. Simulators were incorporated into the code of Monte Carlo MCNPX. Two scenarios were created: in the first (1), lead curtain and protective equipment suspended were not included, and in the second (2) these devices were inserted. The radiographic parameters employed in Monte Carlo simulations were: tube voltage of 60 kVp and 120 kVp; filtration of the beam and 3,5 mmAl beam area of 10 x 10 cm 2 . The average values of CCs to eight projections (in 10 -4 / Gy.cm 2 were 1,2 for the patient, 2,6E-03 (scenario 1) and 4,9E-04 (scenario 2) for cardiologist and 5,2E-04 (scenario 1) and 4,0E-04 (Scenario 2) to the nurse. The results show a significant reduction in CCs for professionals, when the lead curtain and protective equipment suspended are employed. The evaluation method used in this work can provide important information on the risk of cancer patient and professional, and thus improve the protection of workers in cardiac procedures of RI

  15. Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

    Science.gov (United States)

    Fukuda, Makoto; Yoshimura, Kengo; Namekawa, Koki; Sakai, Kiyotaka

    2017-06-01

    The objective of the present study is to evaluate the effect of filtration coefficient and internal filtration on dialysis fluid flow and mass transfer coefficient in dialyzers using dimensionless mass transfer correlation equations. Aqueous solution of vitamin B 12 clearances were obtained for REXEED-15L as a low flux dialyzer, and APS-15EA and APS-15UA as high flux dialyzers. All the other design specifications were identical for these dialyzers except for filtration coefficient. The overall mass transfer coefficient was calculated, moreover, the exponents of Reynolds number (Re) and film mass transfer coefficient of the dialysis-side fluid (k D ) for each flow rate were derived from the Wilson plot and dimensionless correlation equation. The exponents of Re were 0.4 for the low flux dialyzer whereas 0.5 for the high flux dialyzers. Dialysis fluid of the low flux dialyzer was close to laminar flow because of its low filtration coefficient. On the other hand, dialysis fluid of the high flux dialyzers was assumed to be orthogonal flow. Higher filtration coefficient was associated with higher k D influenced by mass transfer rate through diffusion and internal filtration. Higher filtration coefficient of dialyzers and internal filtration affect orthogonal flow of dialysis fluid.

  16. Rate Coefficients for the OH + (CHO)2 (Glyoxal) Reaction Between 240 and 400 K

    Science.gov (United States)

    Feierabend, K. J.; Talukdar, R. K.; Zhu, L.; Ravishankara, A. R.; Burkholder, J. B.

    2006-12-01

    Glyoxal (CHO)2, the simplest dialdehyde, is an end product formed in the atmospheric oxidation of biogenic hydrocarbons, for example, isoprene. As such, glyoxal plays a role in regional air quality and ozone production in certain locations. Glyoxal is lost in the atmosphere via UV photolysis and reaction with OH. However, the currently available rate coefficient data for the OH + glyoxal reaction is limited to a single room- temperature measurement made using the relative rate method. A determination of the rate coefficient temperature dependence is therefore needed for a more complete interpretation of the atmospheric processing of glyoxal. This study reports the rate coefficient for the OH + (CHO)2 reaction measured under pseudo- first-order conditions in OH ([(CHO)2] > 1000 [OH]0). OH radicals were produced using 248 nm pulsed laser photolysis of H2O2 or HNO3 and detected by pulsed laser induced fluorescence. The concentration of glyoxal in the reactor was determined using three independent techniques; gas flow rates as well as in situ UV and IR absorption. The total pressure in the reactor was varied from 40 to 300 Torr (He), and the rate coefficient was found to be independent of pressure over the temperature range studied. The rate coefficient exhibits a negative temperature dependence between 240 and 400 K consistent with the dependence previously observed for many other aldehydes. Our room-temperature rate coefficient is smaller than the relative rate value that is currently recommended for use in atmospheric model calculations. Our measured rate coefficients are discussed with respect to those for other aldehydes. The atmospheric implications of our work will also be discussed.

  17. Absorption and backscatter of internal conversion electrons in the measurements of surface contamination of 137Cs

    International Nuclear Information System (INIS)

    Yunoki, A.; Kawada, Y.; Yamada, T.; Unno, Y.; Sato, Y.; Hino, Y.

    2013-01-01

    We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross β-particles and also β-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and β-rays were revealed. Although the abundance of internal conversion electrons of 137 Cs- 137 Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring. - Highlights: • Counting efficiencies for internal conversion electrons from 137 Cs were measured, and compared with those for β-rays. • Electron-X coincidence technique was employed. • A thin NaI(Tl) scintillation detector was used for X-ray detection. • Backscattering fractions of electrons and beta particles were studied by similar experiments

  18. Activity coefficients in (hydrogen chloride+holmium chloride) (aq) from T=(278.15 to 328.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Rabindra N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States)]. E-mail: rroy@drury.edu; Roy, Lakshmi N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Tabor, Bennett J. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Richards, Sarah J. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Cummins, Mason P. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Himes, Curtis A. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Gibbs, Stephanie N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Christiansen, Edward B. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States)

    2005-07-15

    Activity coefficients of HCl in (hydrogen chloride+holmium chloride) (aq) have been calculated from the observed e.m.f.s using the Nernst equation. The temperatures ranged from (278.15 to 328.15) K at 5 K intervals and at constant total ionic strengths of (0.01, 0.025, 0.05, 0.1, 0.25, 0.5, 1.0, and 1.5) mol.kg{sup -1}. Electromotive-force measurements were made on the cell without liquid junction of the type:Pt vertical bar H{sub 2}(g,p=101.325kPa) vertical bar HCl(m{sub A}),HoCl{sub 3}(m{sub B}) vertical bar AgCl(s), vertical bar Ag(s) The results of the activity coefficients of HCl for this mixed electrolyte mixture have been interpreted in terms of the simpler Harned's equations and the ion-interaction model of Pitzer. Results show that the quadratic term is sufficient for the full range of Y{sub B} (the ionic strength fraction of the salt) to 0.9 at all the ionic strengths studied. The Pitzer's mixing parameters S{sub {theta}}{sub H,Ho} and {psi}{sub H,Ho,Cl} (including higher order electrostatic effects) and {theta}{sub H,Ho} and {psi}{sub H,Ho,Cl} (excluding higher order electrostatic effects) have been determined. These values at T=298.15 K are: S{sub {theta}}{sub H},{sub Ho}=0.115, {psi}{sub H,Ho,Cl}=-.071; and {theta}{sub H,Ho}=-.663, {psi}{sub H,Ho,Cl}=0.165. The parameters obtained in this study reproduce the activity coefficients of HCl in the mixtures within 0.015 over the entire range of ionic strengths and within 0.009 for I>=0.05 mol.kg{sup -1} over the entire temperature range.

  19. Developing the theory of nonstationary neutron transport in a homogeneous infinite medium. γk coefficients

    International Nuclear Information System (INIS)

    Trukhanov, G.Ya.

    2005-01-01

    Time-dependent neutron transport theory of G.Ya. Trukhanov and S.A. Podosenov is developed. Errors of calculating of power series expansion coefficients, γ k , in this theory were estimated. It has been found that power series convergence radius R=|χ 1,2 |= 0.9595. Power series convergence speed were estimated [ru

  20. Calculating the heat transfer coefficient of frame profiles with internal cavities

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2004-01-01

    . The heat transfer coefficient is determined by two-dimensional numerical calculations and by measurements. Calculations are performed in Therm (LBNL (2001)), which is developed at Lawrence Berkeley National Laboratory, USA. The calculations are performed in accordance with the future European standards...... correspondence between measured and calculated values. Hence, when determining the heat transfer coefficient of frame profiles with internal cavities by calculations, it is necessary to apply a more detailed radiation exchange model than described in the prEN ISO 10077-2 standard. The ISO-standard offers......Determining the energy performance of windows requires detailed knowledge of the thermal properties of their different elements. A series of standards and guidelines exist in this area. The thermal properties of the frame can be determined either by detailed two-dimensional numerical methods...

  1. ICP-MS measurement of silver diffusion coefficient in graphite IG-110 between 1048K and 1284K

    Science.gov (United States)

    Carter, L. M.; Seelig, J. D.; Brockman, J. D.; Robertson, J. D.; Loyalka, S. K.

    2018-01-01

    Silver-110m has been shown to permeate intact silicon carbide and pyrolytic carbon coating layers of the TRISO fuel particles during normal High Temperature Gas-Cooled Reactor (HTGR) operational conditions. The diffusion coefficients for silver in graphite IG-110 measured using a release method designed to simulate HTGR conditions of high temperature and flowing helium in the temperature range 1048-1253 K are reported. The measurements were made using spheres milled from IG-110 graphite that were infused with silver using a pressure vessel technique. The Ag diffusion was measured using a time release technique with an ICP-MS instrument for detection. The results of this work are:

  2. Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    Absorbed-dose conversion coefficients are calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months when the mother's body is exposed to protons and photons from top-down (TOP) direction. It provides data sets in addition to other standard irradiation geometries published previously. The TOP-irradiation geometry is considered here, because high-energy particles are often peaked from the TOP direction onboard aircraft. The results show that absorbed-doses from high-energy particles could be underestimated significantly if isotropic (ISO) irradiation geometry is assumed. For protons of 100 GeV, absorbed-doses from TOP irradiation are ∼2.3-2.9 times higher than the doses from ISO irradiation for different foetal ages. For 10 GeV photons, foetal doses from TOP irradiation are ∼6.8-12 times higher than the doses from ISO irradiation. The coefficients from TOP-irradiation geometry are given in wide energy ranges, from 100 MeV to 100 GeV for protons and from 50 V to 10 GeV for photons. They can, therefore, be used in various applications whenever exposure from the TOP-irradiation direction is concerned. (authors)

  3. Controlling the Internal Heat Transfer Coefficient by the Characteristics of External Flows

    Science.gov (United States)

    Zhuromskii, V. M.

    2018-01-01

    The engineering-physical fundamentals of substance synthesis in a boiling apparatus are presented. We have modeled a system of automatic stabilization of the maximum internal heat transfer coefficient in such an apparatus by the characteristics of external flows on the basis of adaptive seeking algorithms. The results of operation of the system in the shop are presented.

  4. Calorimetric Measurement for Internal Conversion Efficiency of Photovoltaic Cells/Modules Based on Electrical Substitution Method

    Science.gov (United States)

    Saito, Terubumi; Tatsuta, Muneaki; Abe, Yamato; Takesawa, Minato

    2018-02-01

    We have succeeded in the direct measurement for solar cell/module internal conversion efficiency based on a calorimetric method or electrical substitution method by which the absorbed radiant power is determined by replacing the heat absorbed in the cell/module with the electrical power. The technique is advantageous in that the reflectance and transmittance measurements, which are required in the conventional methods, are not necessary. Also, the internal quantum efficiency can be derived from conversion efficiencies by using the average photon energy. Agreements of the measured data with the values estimated from the nominal values support the validity of this technique.

  5. Fluence-to-Absorbed Dose Conversion Coefficients for Use in Radiological Protection of Embryo and Foetus Against External Exposure to Muons from 20MeV to 50GeV

    International Nuclear Information System (INIS)

    Chen Jing

    2008-01-01

    This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients are yet unknown, the results presented here fill a data gap

  6. Abstracts of the international scientific-practical conference on space research, technology and conversion-II

    International Nuclear Information System (INIS)

    1997-04-01

    The International Conference on space research, technology and conversion-II was held on 16-18 April, 1997 in Tashkent, Uzbekistan. The specialists discussed various aspects of space research, technology and conversion problems. More than 60 talks were presented in the meeting on the following subjects: remote sensing and the processing of satellite information; space navigation and others, including radiation effects in silicon solar cells caused by cosmic radiation. (A.A.D.)

  7. Rapid internalization of the oncogenic K+ channel K(V10.1.

    Directory of Open Access Journals (Sweden)

    Tobias Kohl

    Full Text Available K(V10.1 is a mammalian brain voltage-gated potassium channel whose ectopic expression outside of the brain has been proven relevant for tumor biology. Promotion of cancer cell proliferation by K(V10.1 depends largely on ion flow, but some oncogenic properties remain in the absence of ion permeation. Additionally, K(V10.1 surface populations are small compared to large intracellular pools. Control of protein turnover within cells is key to both cellular plasticity and homeostasis, and therefore we set out to analyze how endocytic trafficking participates in controlling K(V10.1 intracellular distribution and life cycle. To follow plasma membrane K(V10.1 selectively, we generated a modified channel of displaying an extracellular affinity tag for surface labeling by α-bungarotoxin. This modification only minimally affected K(V10.1 electrophysiological properties. Using a combination of microscopy and biochemistry techniques, we show that K(V10.1 is constitutively internalized involving at least two distinct pathways of endocytosis and mainly sorted to lysosomes. This occurs at a relatively fast rate. Simultaneously, recycling seems to contribute to maintain basal K(V10.1 surface levels. Brief K(V10.1 surface half-life and rapid lysosomal targeting is a relevant factor to be taken into account for potential drug delivery and targeting strategies directed against K(V10.1 on tumor cells.

  8. 76 FR 38448 - In the Matter of International Poultry Co., Inc. (n/k/a Carley Enterprises, Inc.), International...

    Science.gov (United States)

    2011-06-30

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of International Poultry Co., Inc. (n/k/a Carley Enterprises, Inc.), International Thoroughbred Breeders, Inc., Internet Marketing..., Inc. (n/k/a Salus Labs International, Inc.), Itemus, Inc., and ITIS Holdings, Inc. ; Order of...

  9. Unusual conversations: A reflection on the mechanics of internationally engaged public scholarship

    Directory of Open Access Journals (Sweden)

    Jonathan Damiani

    2016-09-01

    Full Text Available This article analyses the civic engagement pathways of researchers from the Asia-Pacific and the United States in an effort to see how the principles of what American  scholars consider publicly engaged research and creative practice are being enacted in research sites across the globe. The purpose of this ongoing project is to focus on finding ways of connecting American scholars with a network of higher education and research institutions that hold a commitment and passion for social responsibility and civic engagement as it impacts education, research and service for community development overseas. The narrative includes the voices and perspectives of colleagues dedicated to engaged scholarship from across the new region in which I work (the Asia-Pacific, alongside the voices of some of Imagining America’s (IA 2014 National Conference participants. These conversations serve as a critical reflection on the mechanics of doing public scholarship overseas and frame a new model of internationally engaged scholarship. Keywords: Internationally engaged public scholarship, unusual conversations

  10. Osmotic coefficients of aqueous solutions of four ionic liquids at T = (313.15 and 333.15) K

    International Nuclear Information System (INIS)

    Gonzalez, Begona; Calvar, Noelia; Dominguez, Angeles; Macedo, Eugenia A.

    2008-01-01

    Measurements of osmotic coefficients of BmimCl (1-butyl-3-methylimidazolium chloride), HmimCl (1-hexyl-3-methylimidazolium chloride), MmimMeSO 4 (1,3-dimethylimidazolium methylsulfate), and BmimMeSO 4 (1-butyl-3-methylimidazolium methylsulfate) with water at T = (313.15 and 333.15) K are reported in this work. Vapour pressure and activity data of all the studied binary systems are obtained from experimental data. The osmotic coefficients data are correlated using the extended Pitzer model of Archer and the modified NRTL (MNRTL) model and standard deviations obtained with both models are given too. The parameters obtained with the extended Pitzer model of Archer are used to calculate the mean molal activity coefficients

  11. Vapor pressures, osmotic and activity coefficients for (LiBr + acetonitrile) between the temperatures (298.15 and 343.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Nasirzadeh, Karamat E-mail: karamat.nasirzadeh@chemie.uni-regensburg.de; Neueder, Roland; Kunz, Werner

    2004-06-01

    Precise vapor pressure data for pure acetonitrile and (LiBr + acetonitrile) are given for temperatures ranging from T=(298.15 to 343.15) K. The molality range is from m=(0.0579 to 0.8298) mol {center_dot} kg{sup -1}. The osmotic coefficients are calculated by taking into account the second virial coefficient of acetonitrile. The parameters of the extended Pitzer ion interaction model of Archer and the mole fraction-based thermodynamic model of Clegg-Pitzer are evaluated. These models accurately reproduce the available osmotic coefficients. The parameters of the extended Pitzer ion interaction model of Archer are used to calculate the mean molal activity coefficients.

  12. Measurement of secondary cosmic radiation and calculation of associated dose conversion coefficients for humans

    International Nuclear Information System (INIS)

    Simmer, Gregor

    2012-01-01

    Due to secondary cosmic radiation (SCR), pilots and flight attendants receive elevated effective doses at flight altitudes. For this reason, since 2003 aircrew members are considered as occupationally exposed, in Germany. This work deals with the calculation of dose conversion coefficients (DCC) for protons, neutrons, electrons, positrons, photons and myons, which are crucial for estimation of effective dose from SCR. For the first time, calculations were performed combining Geant4 - a Monte Carlo code developed at CERN - with the voxel phantoms for the reference female and male published in 2008 by ICRP and ICRU. Furthermore, measurements of neutron fluence spectra - which contribute the major part to the effective dose of SCR - were carried out at the Environmental Research Station Schneefernerhaus (UFS) located at 2650 m above sea level nearby the Zugspitze mountain, Germany. These measured neutron spectra, and additionally available calculated spectra, were then folded with the DCC calculated in this work, and effective dose rates for different heights were calculated.

  13. Linear mode conversion in a toroidal plasma

    International Nuclear Information System (INIS)

    Hellsten, T.

    1980-05-01

    Linear mode conversion at the perpendicular ion cyclotron resonance has been treated for an axially symmetric toroidal plasma. The mode conversion appears between a fast electromagnetic wave and a slow-quasi electrostatic wave, due to finite electron inertia. The problem reduces to the Orr-Sommerfeld equation where the coefficients determining the reflectron, transmission and conversion are functions of the arc length along a poloidal intersection of the resonance surface. These coefficients can be determined from eigenfunctions of an ordinary differential equation. (author)

  14. Comparison of coal reactivity during conversion into different oxidizing medium

    International Nuclear Information System (INIS)

    Korotkikh, A G; Slyusarskiy, K V; Larionov, K B; Osipov, V I

    2016-01-01

    Acoal conversion process of different coal samples into three different types of oxidizing medium (argon, air and steam) were studied by means of thermogravimetry. Two coal types with different metamorphism degree (lignite and bituminous coal) were used. The experimental procedure was carried out in non-isothermal conditions in temperature range from 373 K to 1273 K with 20 K/min heating rate. Purge gas consisted of argon and oxidizer with volumetric ratio 1:24 and had 250 ml/min flow rate.The ignition and burnout indexes were calculated to evaluate sample reactivity at different oxidizing mediums. The highest reactivity coefficient values in same atmosphere were obtained for lignite. It was caused by higher particle special surface area and volatile matter content. (paper)

  15. Effect of internal pressure and gas/liquid interface area on the CO mass transfer coefficient using hollow fibre membranes as a high mass transfer gas diffusing system for microbial syngas fermentation.

    Science.gov (United States)

    Yasin, Muhammad; Park, Shinyoung; Jeong, Yeseul; Lee, Eun Yeol; Lee, Jinwon; Chang, In Seop

    2014-10-01

    This study proposed a submerged hollow fibre membrane bioreactor (HFMBR) system capable of achieving high carbon monoxide (CO) mass transfer for applications in microbial synthesis gas conversion systems. Hydrophobic polyvinylidene fluoride (PVDF) membrane fibres were used to fabricate a membrane module, which was used for pressurising CO in water phase. Pressure through the hollow fibre lumen (P) and membrane surface area per unit working volume of the liquid (A(S)/V(L)) were used as controllable parameters to determine gas-liquid volumetric mass transfer coefficient (k(L)a) values. We found a k(L)a of 135.72 h(-1) when P was 93.76 kPa and AS/VL was fixed at 27.5m(-1). A higher k(L)a of 155.16 h(-1) was achieved by increasing AS/VL to 62.5m(-1) at a lower P of 37.23 kPa. Practicality of HFMBR to support microbial growth and organic product formation was assessed by CO/CO2 fermentation using Eubacterium limosum KIST612. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Measurement of X-ray mass attenuation coefficient of nickel around the K-edge using synchrotron radiation based X-ray absorption study

    International Nuclear Information System (INIS)

    Roy, Bunty Rani; Rajput, Parasmani; Jha, S.N.; Nageswara Rao, A.S.

    2015-01-01

    The work presents the X-ray absorption fine structure (XAFS) technique for measuring the X-ray mass attenuation coefficient of nickel metal foil in the X-ray energy range of 8271.2–8849.4 eV using scanning XAFS beam line (BL-09) at Indus-2 synchrotron radiation source facility, Raja Ramanna Centre for Advanced Technology (RRCAT) at Indore, India. The result represents the X-ray mass attenuation coefficient data for 0.02 mm thick Ni metal foil in the XAFS region of Ni K-edge. However, the results are compared to theoretical values using X-COM. There is a maximum deviation which is found exactly near the K-edge jump and decreases as we move away from the absorption edge. Oscillatory structure appears just above the observed absorption edge i.e., 8348.7 eV and is confined to around 250 eV above the edge. - Highlights: • Mass attenuation coefficient measurements of nickel using synchrotron radiation. • The measurements were taken exactly near the Ni K-edge at an energy step of 1 eV. • A maximum deviation is found near the K-edge

  17. Fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to protons from 100 MeV to 100 GeV

    International Nuclear Information System (INIS)

    Chen, J.

    2006-01-01

    In the literature, no conversion coefficients are available for use in radiological protection of embryo and foetus against external exposure to protons. This study used the Monte Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to proton fields. Monoenergetic protons ranging from 100 MeV to 100 GeV were considered. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO). At each of these standard irradiation geometries, absorbed doses to the foetal brain and body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months. Proton fluence-to-absorbed dose conversion coefficients were derived for the four prenatal ages. (authors)

  18. Mutual diffusion coefficients of L-glutamic acid and monosodium L-glutamate in aqueous solutions at T = 298.15 K

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Rodrigo, M.M.; Barros, Marisa C.F.; Verissimo, Luis M.P.; Romero, Carmen; Valente, Artur J.M.; Esteso, Miguel A.

    2014-01-01

    Highlights: • Interdiffusion coefficients of L-glutamic acid and sodium L-glutamate were measured. • The L-glutamic acid behaves as a monoprotic weak acid. • The sodium L-glutamate shows a symmetrical 1:1 non-associated behaviour. • Limiting diffusion coefficients and ionic conductivities were estimated. • Diffusion coefficients were discussed on the basis of the Onsager–Fuoss equations. - Abstract: Mutual diffusion coefficient values for binary aqueous solutions of both L-glutamic acid (H 2 Glu) and sodium L-glutamate (NaHGlu) were measured with the Taylor dispersion technique, at T = 298.15 K, and concentrations ranging from (0.001 to 0.100) mol · dm −3 . The results were discussed on the basis of the Onsager–Fuoss and the Nernst theoretical equations, by considering the H 2 Glu as a weak acid (monoprotic acid, with K 2 = 5.62 · 10 −5 ). The smaller values found for the acid with respect to those of the salt, confirm this association hypothesis. From the diffusion coefficient values at infinitesimal concentration, limiting ionic conductivities as well as the hydrodynamic radius of the hydrogen glutamate ion (HGlu − ) were derived and analyzed in terms of the chain methylene groups. The effect of different phenomena, such as association or complexation, were also taken into consideration and discussed. Values for the dissociation degree for H 2 Glu were also estimated

  19. Helions at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2010-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent, for isotropic exposure of an adult male and an adult female to helions ( 3 He 2+ ) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Calculations were performed using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms modified to allow calculation of effective dose using tissues and tissue weighting factors from either the 1990 or 2007 recommendations of the International Commission on Radiological Protection (ICRP), and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 2%. The greatest difference, 62%, occurred at 100 MeV. Published by Oxford Univ. Press on behalf of the U.S. Government 2010. (authors)

  20. Catalytic properties of pure and K+-doped Cu O/Mg O system towards 2-propanol conversion

    International Nuclear Information System (INIS)

    El-Molla, S. A.; Amin, N. H.; Hammed, M. N.; Sultan, S. N.; El-Shobaky, G. A.

    2013-01-01

    Cu O/Mg O system having different compositions was prepared by impregnation method followed by calcination at 400-900 C. The effect of Cu O content, calcination temperature and doping with small amounts of K + species (1-3 mol %) on physicochemical, surface and catalytic properties of the system were investigated using X-ray diffraction, adsorption of N 2 at - 196 C, and conversion of isopropyl alcohol at 150-400 C using a flow technique. The results revealed that the solids having the formulae 0.2 and 0.3 Cu O/Mg O calcined at 400 C consisted of nano sized Mg O and Cu O as major phases together with Cu 2 O as minor phase. The Bet-surface areas of different absorbents are decreased by increasing Cu O content, calcination temperature and K + -doping. Mg O-support material showed very small catalytic activity in 2-propanol conversion. The investigated system behaved as selective catalyst for dehydrogenation of 2-propanol with selectivity >80%. The catalytic activity increased by increasing Cu O content and decreased by increasing the calcination temperature within 400-900 C. K + -doping increased the catalytic activity and catalytic durability. (Author)

  1. 100 kWe lunar/Mars surface power utilizing the SP-100 reactor with dynamic conversion

    International Nuclear Information System (INIS)

    Harty, R.B.; Mason, L.S.

    1992-01-01

    This paper reports on an integration study which was performed coupling an SP-100 reactor with either a Brayton of Stirling power conversion subsystem. a power level of 100 kWe was selected for the study. The power system was to be compatible with both the lunar and Mars surface environment and require no site preparation. In addition, the reactor was to have integral shielding and be completely self-contained, including its own auxiliary power for start-up. Initial reliability studies were performed to determine power conversion redundancy and engine module size. For the lunar environment, the reactor and primary coolant loop would be contained in a guard vessel to protect from a loss of primary loop containment. For the Mars environment, all refractory components including the reactor, primary coolant, and power conversion components would be contained in a vacuum vessel for protection against the CO 2 environment

  2. Maximum Efficiency of Thermoelectric Heat Conversion in High-Temperature Power Devices

    Directory of Open Access Journals (Sweden)

    V. I. Khvesyuk

    2016-01-01

    Full Text Available Modern trends in development of aircraft engineering go with development of vehicles of the fifth generation. The features of aircrafts of the fifth generation are motivation to use new high-performance systems of onboard power supply. The operating temperature of the outer walls of engines is of 800–1000 K. This corresponds to radiation heat flux of 10 kW/m2 . The thermal energy including radiation of the engine wall may potentially be converted into electricity. The main objective of this paper is to analyze if it is possible to use a high efficiency thermoelectric conversion of heat into electricity. The paper considers issues such as working processes, choice of materials, and optimization of thermoelectric conversion. It presents the analysis results of operating conditions of thermoelectric generator (TEG used in advanced hightemperature power devices. A high-temperature heat source is a favorable factor for the thermoelectric conversion of heat. It is shown that for existing thermoelectric materials a theoretical conversion efficiency can reach the level of 15–20% at temperatures up to 1500 K and available values of Ioffe parameter being ZT = 2–3 (Z is figure of merit, T is temperature. To ensure temperature regime and high efficiency thermoelectric conversion simultaneously it is necessary to have a certain match between TEG power, temperature of hot and cold surfaces, and heat transfer coefficient of the cooling system. The paper discusses a concept of radiation absorber on the TEG hot surface. The analysis has demonstrated a number of potentialities for highly efficient conversion through using the TEG in high-temperature power devices. This work has been implemented under support of the Ministry of Education and Science of the Russian Federation; project No. 1145 (the programme “Organization of Research Engineering Activities”.

  3. Coefficient estimates of negative powers and inverse coefficients for ...

    Indian Academy of Sciences (India)

    and the inequality is sharp for the inverse of the Koebe function k(z) = z/(1 − z)2. An alternative approach to the inverse coefficient problem for functions in the class S has been investigated by Schaeffer and Spencer [27] and FitzGerald [6]. Although, the inverse coefficient problem for the class S has been completely solved ...

  4. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

    Science.gov (United States)

    Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen

    2013-12-02

    Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.

  5. Estimated fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to photons from 50 keV to 10 GeV

    International Nuclear Information System (INIS)

    Chen, J.

    2006-01-01

    In the literature, no conversion coefficients are available for use in radiological protection of the embryo and foetus against external exposure to photons. This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external photon fields. Monoenergetic photons ranging from 50 keV to 10 GeV were considered. The irradiation geometries included antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), and isotropic (ISO). At each of these standard irradiation geometries, absorbed doses to the foetal brain and body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months. Photon fluence-to-absorbed-dose conversion coefficients were estimated for the four prenatal ages. (authors)

  6. Spectral effects on some physical coefficients of x-Ray interaction with materials of low atomic number

    International Nuclear Information System (INIS)

    EL-Kazzaz, S.A.; Youssef, M.; EL-Hadad, S.; and EL-Nadi, L.M.

    1988-01-01

    X-ray spectra were measured before and after passing through some materials of medical importance applying X-ray diffraction. The mass absorption coefficients of these materials were determined at X-ray peak voltages 27, 30 and 42 kV-p making use the measured spectrum and also by using the direct beam absorption. It has been found that the mass absorption coefficients calculated from the X-ray spectral distribution analysis are in general lower than those obtained considering the direct beam method. From the study of the atomic number and energy dependence of the mass absorption coefficients it has been found that the dependence of the coefficients calculated from the spectral distribution is good agreement with the previously studied data for monoenergetic x-ray beam. Also the roentgen - to - Rad conversion factors were determined at the different used energies and materials. The value of the mass absorption coefficients calculated from the spectral distribution is recommended for use in dose calculation

  7. Activity coefficients of CaCl{sub 2} in (serine or proline + water) mixtures at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Ma Jingjing [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China); Zhang Xinkuan [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China); School of Chemistry and Chemical Engineering, Xinxiang University, Xinxiang, Henan 453003 (China); Zhuo Kelei, E-mail: lchow@mail.ucf.ed [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China); Liu Hongxun; Wang Jianji [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China)

    2010-05-15

    Activity coefficients for the (CaCl{sub 2} + amino acid + water) system were determined at a temperature of 298.15 K using ion-selective electrodes. The range of molalities of CaCl{sub 2} is (0.01 to 0.20) mol . kg{sup -1}, and that of amino acids is (0.10 to 0.40) mol . kg{sup -1}. The activity coefficients obtained from the Debye-Hueckel extended equation and the Pitzer equation are in good agreement with each other. Results show that the interactions between CaCl{sub 2} and amino acid are controlled mainly by the electrostatic interactions (attraction). Gibbs free energy interaction parameters (g{sub EA}) and salting constants (k{sub S}) are positive, indicating that these amino acids are salted out by CaCl{sub 2}. These results are discussed based on group additivity model.

  8. Activity coefficients of CaCl{sub 2} in (maltose + water) and (lactose + water) mixtures at 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Zhuo Kelei [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China)], E-mail: klzhuo@263.net; Liu Hongxun; Zhang Honghao; Liu Yaohui; Wang Jianji [School of Chemistry and Environmental Science, Henan Normal University, Xinxiang, Henan 453007 (China)

    2008-05-15

    Activity coefficients of CaCl{sub 2} in disaccharide {l_brace}(maltose, lactose) + water{r_brace} mixtures at 298.15 K were determined by cell potentials. The molalities of CaCl{sub 2} ranged from about 0.01 mol . kg{sup -1} to 0.20 mol . kg{sup -1}, the mass fractions of maltose from 0.05 to 0.25, and those of lactose from 0.025 to 0.125. The cell potentials were analyzed by using the Debye-Hueckel extended equation and the Pitzer equation. The activity coefficients obtained from the two theoretical models are in good agreement with each other. Gibbs free energy interaction parameters (g{sub ES}) and salting constants (k{sub S}) were also obtained. These were discussed in terms of the stereo-chemistry of saccharide molecules and the structural interaction model.

  9. Measurement of mass attenuation coefficients around the K absorption edge by parametric X-rays

    International Nuclear Information System (INIS)

    Tamura, Masaya; Akimoto, Tadashi; Aoki, Yohei; Ikeda, Jiro; Sato, Koichi; Fujita, Fumiyuki; Homma, Akira; Sawamura, Teruko; Narita, Masakuni

    2002-01-01

    When electrons at relativistic velocities pass through a crystal plate, such as silicon, photons are emitted around the Bragg angle for X-ray diffraction. This phenomenon is called parametric X-ray radiation (PXR). The monochromaticity and directivity of PXR are adequate and the energy can be changed continuously by rotating the crystal. This study measured the mass attenuation coefficient around the K-shell absorption edge of Nb, Zr and Mo as a PXR application of monochromatic hard X-ray radiation sources

  10. Measurement of mass attenuation coefficients around the K absorption edge by parametric X-rays

    CERN Document Server

    Tamura, M; Aoki, Y; Ikeda, J; Sato, K; Fujita, F; Homma, A; Sawamura, T; Narita, M

    2002-01-01

    When electrons at relativistic velocities pass through a crystal plate, such as silicon, photons are emitted around the Bragg angle for X-ray diffraction. This phenomenon is called parametric X-ray radiation (PXR). The monochromaticity and directivity of PXR are adequate and the energy can be changed continuously by rotating the crystal. This study measured the mass attenuation coefficient around the K-shell absorption edge of Nb, Zr and Mo as a PXR application of monochromatic hard X-ray radiation sources.

  11. Anomalous field dependence of the Sommerfeld coefficient in the isotropic (K,Ba)BiO3 superconductor

    International Nuclear Information System (INIS)

    Klein, T.; Marcenat, C.; Bouquet, F.; Junod, A.; Blanchard, S.; Marcus, J.

    2004-01-01

    We report on specific heat measurements in high quality (K,Ba)BiO 3 single crystals (T c ∼31.5 K). A well defined specific heat jump is clearly visible at T C p (H) in the entire investigated field range (up to 13 T). However, the corresponding T C p (H) exhibits an anomalous positive curvature and the amplitude of the jump rapidly decreases with field suggesting a non-linear increase of the Sommerfeld coefficient (γ(H)). This anomalous behaviour is confirmed by low temperature measurements which show that γ(H)∝H α with α∼0.65

  12. Transfer coefficients of energy in mass for X radiation-air: the kV relation and effective energy

    International Nuclear Information System (INIS)

    Teixeira, G.J.; Sousa, C.H.S.; Peixoto, J.G.P.

    2014-01-01

    The objective was to determine, through specific software, the mass-energy transfer coefficients by X-ray beams in air between 30-150 kV. Were generated by the Spectrum Processor program, the spectra and calculated their mass coefficients. The results behaved numerically decreasing order, ranging between 0.3733 and 0.0439 cm 2 /g, inversely proportional to the voltage used and differing behavior of mono-energetic beams above 100 keV. Values align with literal definitions of the interaction of radiation with matter, being useful for dosimetry in diagnostic radiology, including for systems not using an ionization chamber. (author)

  13. Validity of the CT to attenuation coefficient map conversion methods

    International Nuclear Information System (INIS)

    Faghihi, R.; Ahangari Shahdehi, R.; Fazilat Moadeli, M.

    2004-01-01

    The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result

  14. Activity coefficients of LiCl in (PEG 4000 + water) at T = (288.15, 298.15, and 308.15) K

    International Nuclear Information System (INIS)

    Morales, Jaime W.; Galleguillos, Hector R.; Graber, Teofilo A.; Hernandez-Luis, Felipe

    2010-01-01

    The electromotive force of the cell containing two ion-selective electrodes (ISE), Na-ISE|LiCl(m),PEG4000(w),H 2 O(1-w)|Cl-ISE has been measured at temperatures of (288.15, 298.15, and 308.15) K as a function of the mass fraction of PEG 4000 (w) in the mixture. w was varied between 0 and 0.25 in 0.05-unit steps and the molality of the electrolyte (m) was between c.a. (0.03 and 5.8) mol . kg -1 . The values of the standard electromotive force, E 0 , were determined using routine methods of extrapolation, together with extended Debye-Hueckel and Pitzer equations. The results obtained produced good internal consistency for all the temperatures studied. Once E 0 was determined, the mean ionic activity coefficients for LiCl, the Gibbs free energy of transfer from the water to (PEG 4000 + water), and the primary LiCl hydration number were calculated.

  15. Activity coefficients of LiCl in (PEG 4000 + water) at T = (288.15, 298.15, and 308.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Jaime W.; Galleguillos, Hector R.; Graber, Teofilo A. [Centro de Investigacion Cientifico y Tecnologico para la Mineria, Departamento de Ingenieria Quimica, Universidad de Antofagasta (Chile); Hernandez-Luis, Felipe, E-mail: ffhelu@ull.e [Departamento de Quimica Fisica, Universidad de La Laguna, Tenerife (Spain)

    2010-10-15

    The electromotive force of the cell containing two ion-selective electrodes (ISE), Na-ISE|LiCl(m),PEG4000(w),H{sub 2}O(1-w)|Cl-ISE has been measured at temperatures of (288.15, 298.15, and 308.15) K as a function of the mass fraction of PEG 4000 (w) in the mixture. w was varied between 0 and 0.25 in 0.05-unit steps and the molality of the electrolyte (m) was between c.a. (0.03 and 5.8) mol . kg{sup -1}. The values of the standard electromotive force, E{sup 0}, were determined using routine methods of extrapolation, together with extended Debye-Hueckel and Pitzer equations. The results obtained produced good internal consistency for all the temperatures studied. Once E{sup 0} was determined, the mean ionic activity coefficients for LiCl, the Gibbs free energy of transfer from the water to (PEG 4000 + water), and the primary LiCl hydration number were calculated.

  16. Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis

    Science.gov (United States)

    Chen, Wen; Tang, Ming

    2017-04-01

    The abnormal temperature rise is the precursor of the defective composite insulator in power transmission line. However no consolidated techniques or methodologies can on line monitor its internal temperature now. Thus a new method using embedding fiber Bragg grating (FBG) in fiber reinforced polymer (FRP) rod is adopted to monitor its internal temperature. To correctly demodulate the internal temperature of FRP rod from the Bragg wavelength shift of FBG, the conversion coefficient between them is deduced theoretically based on comprehensive investigation on the thermal stresses of the metal-composite joint, as well as its material and structural properties. Theoretical model shows that the conversion coefficients of FBG embedded in different positions will be different because of non-uniform thermal stress distribution, which is verified by an experiment. This work lays the theoretical foundation of monitoring the internal temperature of composite insulator with embedding FBG, which is of great importance to its health structural monitoring, especially early diagnosis.

  17. Precise calculation of the transmission coefficient of a potential barrier. Study of the error in the B K W approximation; Calcul exact du coefficient de transmission d'une barriere de potentiel. Etude de l'erreur de l'approximation B K W

    Energy Technology Data Exchange (ETDEWEB)

    Jamet, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Following on to work started in a previous report, the author carries out in the case of few examples, the calculation of the transmission coefficient T using accurate methods. He then deduces from this the error in the B K W method. The calculations are carried out for values of T ranging down to 10{sup -200}. The use of modern computers makes it possible to obtain values of T to eight decimal places in a few seconds and the practical advantage of the B K W approximation appears therefore considerably reduced. The author gives also a method which may be used for an exact calculation of the energy levels of a potential well. (author) [French] Poursuivant une etude commencee dans une note anterieure, l'auteur effectue, sur quelques exemples, le calcul du coefficient de transmission T par des methodes exactes. Il en deduit ensuite l'erreur de la methode B K W. Les calculs sont faits pour des valeurs de T allant jusqu'a 10{sup -200}. L'utilisation des machines a calculer modernes permettant d'obtenir en quelques secondes, la valeur de T avec 8 decimales exactes, l'interet pratique de l'approximation B K W semble considerablement diminue. L'auteur indique egalement une methode qui peut servir a calculer exactement les niveaux d'energie d'un puits de potentiel. (auteur)

  18. Vapour pressures, osmotic and activity coefficients for binary mixtures containing (1-ethylpyridinium ethylsulfate + several alcohols) at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gomez, Elena; Dominguez, Angeles; Macedo, Eugenia A.

    2010-01-01

    Osmotic coefficients of binary mixtures containing several primary and secondary alcohols (1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol) and the pyridinium-based ionic liquid 1-ethylpyridinium ethylsulfate were determined at T = 323.15 K using the vapour pressure osmometry technique. From the experimental results, vapour pressure and activity coefficients can be determined. For the correlation of osmotic coefficients, the extended Pitzer model modified by Archer, and the modified NRTL (MNRTL) model were used, obtaining deviations lower than 0.017 and 0.047, respectively. The mean molal activity coefficients and the excess Gibbs free energy for the binary mixtures studied were determined from the parameters obtained with the extended Pitzer model modified by Archer.

  19. Incidence and 12-month outcome of non-transient childhood conversion disorder in the U.K. and Ireland.

    Science.gov (United States)

    Ani, Cornelius; Reading, Richard; Lynn, Richard; Forlee, Simone; Garralda, Elena

    2013-06-01

    Little is known about conversion disorder in childhood. To document clinical incidence, features, management and 12-month outcome of non-transient conversion disorder in under 16-year-olds in the U.K. and Ireland. Surveillance through the British Paediatric Surveillance Unit and Child and Adolescent Psychiatry Surveillance System. In total, 204 cases (age range 7-15 years) were reported, giving a 12-month incidence of 1.30/100 000 (95% CI 1.11-1.52). The most common symptoms were motor weakness and abnormal movements. Presentation with multiple symptoms was the norm. Antecedent stressors were reported for 80.8%, most commonly bullying in school. Most children required in-patient admission with frequent medical investigations. Follow-up at 12 months was available for 147 children, when all conversion disorder symptoms were reported as improved. Most families (91%) accepted a non-medical explanation of the symptoms either fully or partially. Childhood conversion disorder represents an infrequent but significant clinical burden in the UK and Ireland.

  20. Towards spontaneous parametric down-conversion at low temperatures

    Directory of Open Access Journals (Sweden)

    Akatiev Dmitrii

    2017-01-01

    Full Text Available The possibility of observing spontaneous parametric down-conversion in doped nonlinear crystals at low temperatures, which would be useful for combining heralded single-photon sources and quantum memories, is studied theoretically. The ordinary refractive index of a lithium niobate crystal doped with magnesium oxide LiNbO3:MgO is measured at liquid nitrogen and helium temperatures. On the basis of the experimental data, the coefficients of the Sellmeier equation are determined for the temperatures from 5 to 300 K. In addition, a poling period of the nonlinear crystal has been calculated for observing type-0 spontaneous parametric down-conversion (ooo-synchronism at the liquid helium temperature under pumping at the wavelength of λp = 532 nm and emission of the signal field at the wavelength of λs = 794 nm, which corresponds to the resonant absorption line of Tm3+ doped ions.

  1. Catalytic properties of pure and K{sup +}-doped Cu O/Mg O system towards 2-propanol conversion

    Energy Technology Data Exchange (ETDEWEB)

    El-Molla, S. A.; Amin, N. H.; Hammed, M. N.; Sultan, S. N. [Ain Shams University, Faculty of Education, Chemistry Department, Roxy, Heliopolis, Cairo 11757 (Egypt); El-Shobaky, G. A., E-mail: saharelmolla@yahoo.com [National Research Center, Dokki, Cairo (Egypt)

    2013-08-01

    Cu O/Mg O system having different compositions was prepared by impregnation method followed by calcination at 400-900 C. The effect of Cu O content, calcination temperature and doping with small amounts of K{sup +} species (1-3 mol %) on physicochemical, surface and catalytic properties of the system were investigated using X-ray diffraction, adsorption of N{sub 2} at - 196 C, and conversion of isopropyl alcohol at 150-400 C using a flow technique. The results revealed that the solids having the formulae 0.2 and 0.3 Cu O/Mg O calcined at 400 C consisted of nano sized Mg O and Cu O as major phases together with Cu{sub 2}O as minor phase. The Bet-surface areas of different absorbents are decreased by increasing Cu O content, calcination temperature and K{sup +}-doping. Mg O-support material showed very small catalytic activity in 2-propanol conversion. The investigated system behaved as selective catalyst for dehydrogenation of 2-propanol with selectivity >80%. The catalytic activity increased by increasing Cu O content and decreased by increasing the calcination temperature within 400-900 C. K{sup +}-doping increased the catalytic activity and catalytic durability. (Author)

  2. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  3. Isopiestic determination of the osmotic and activity coefficients of the {l_brace}yKCl + (1 - y)K{sub 2}HPO{sub 4}{r_brace}(aq) system at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, Daniela Z. [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Miladinovic, Jelena, E-mail: duma@tmf.bg.ac.rs [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Todorovic, Milica D.; Zrilic, Milorad M. [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Rard, Joseph A., E-mail: solution_chemistry2@comcast.net [4363 Claremont Way, Livermore, CA 94550 (United States)

    2011-12-15

    Highlights: > Isopiestic measurements were made for {l_brace}yKCl + (1 - y)K{sub 2}HPO{sub 4}{r_brace}(aq) at T = 298.15 K. > The resulting osmotic coefficients were represented by three thermodynamic models. > Activity coefficients from Pitzer model with Scatchard mixing terms are recommended. - Abstract: The osmotic coefficients of aqueous mixtures of KCl and K{sub 2}HPO{sub 4} have been measured at T = (298.15 {+-} 0.01) K by the isopiestic vapor pressure method over the range of ionic strengths from (2.3700 to 11.250) mol . kg{sup -1} using CaCl{sub 2}(aq) as the reference solution. Our new experimental results were modeled with an extended form of Pitzer's ion-interaction model equations, both with the usual mixing terms and with Scatchard's neutral-electrolyte mixing terms, and with the Clegg-Pitzer-Brimblecombe equations based on the mole-fraction-composition scale. There is a dearth of previously published isopiestic data for mixtures containing salts of HPO{sub 4}{sup 2-}(aq) and, consequently, no previous measurements are available for comparison with the present results. The present study yields Cl{sup -}HPO{sub 4}{sup 2-} mixing parameters for these three models that are needed for modeling the thermodynamic activities of solute components of natural waters and other complex aqueous electrolyte mixtures.

  4. Power coefficient anomaly in JOYO

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H

    1980-12-15

    Operation of the JOYO experimental fast reactor with the MK-I core has been divided into two phases: (1) 50 MWt power ascension and operation; and (2) 75 MWt power ascension and operation. The 50 MWt power-up tests were conducted in August 1978. In these tests, the measured reactivity loss due to power increases from 15 MWt to 50 MWt was 0.28% ..delta.. K/K, and agreed well with the predicted value of 0.27% ..delta.. K/K. The 75 MWt power ascension tests were conducted in July-August 1979. In the process of the first power increase above 50 MWt to 65 MWt conducted on July 11, 1979, an anomalously large negative power coefficient was observed. The value was about twice the power coefficient values measured in the tests below 50 MW. In order to reproduce the anomaly, the reactor power was decreased and again increased up to the maximum power of 65 MWt. However, the large negative power coefficient was not observed at this time. In the succeeding power increase from 65 MWt to 75 MWt, a similar anomalous power coefficient was again observed. This anomaly disappeared in the subsequent power ascensions to 75 MWt, and the magnitude of the power coefficient gradually decreased with power cycles above the 50 MWt level.

  5. A feasibility study of conceptual design for international clean energy network using hydrogen conversion technology

    International Nuclear Information System (INIS)

    Sato, Takashi; Hamada, Akiyoshi; Kitamura, Kazuhiro

    1998-01-01

    Clean energy is more and more required worldwide in proportion to actualization of global environmental issues including global warming. Therefore, it is an urgent task to realize promotion of worldwide introduction of clean energy which exists abundantly and is widely distributed in the world, such as hydropower and solar energy, while reducing the dependence on fossil fuel. However, since the renewable energy, differing from so called fossil fuel, is impossible to transport for long distance and store as it is, its utilization is subject to be limited. As one possible resolution of this kind of issues, 'International clean energy network using hydrogen conversion technology' which enables conversion of renewable energy from low cost hydropower into hydrogen energy and also into the transportable and storable form, is a meaningful concept. This system technology enables dealing of this hydrogen energy in international market as in the same manner as fossil fuel. It is considered to enable promotion of international and large scale introduction of such clean energy, along with the contribution to diversified and stabilized international energy supply. In this study, based upon the above-mentioned point of view and assumption of two sites, one on supply side and another on demand side of hydrogen energy, three systems are presumed. One of the systems consists of liquid hydrogen as transportation and storage medium of hydrogen, and the others intermediately convert hydrogen into methanol or ammonia as an energy carrier. A overall conceptual design of each system spanning from hydrogen production to its utilization, is conducted in practical way in order to review the general technical aspects and economical aspects through cost analysis. This study is administrated through the New Energy and Industrial Technology Development Organization (NEDO) as a part of the International Clean Energy Network Using Hydrogen Conversion (so-called WE-NET) Program with funding from

  6. Data on flow cell optimization for membrane-based electrokinetic energy conversion

    Directory of Open Access Journals (Sweden)

    David Nicolas Østedgaard-Munck

    2017-12-01

    Full Text Available This article elaborates on the design and optimization of a specialized flow cell for the measurement of direct conversion of pressure into electrical energy (Electrokinetic Energy Conversion, EKEC which has been presented in Østedgaard-Munck et al. (2017 [1]. Two main flow cell parameters have been monitored and optimized: A the hydraulic pressure profile on each side of the membrane introduced by pumps recirculating the electrolyte solution through the flow fields and B the electrical resistance between the current collectors across the combined flow cell. The latter parameter has been measured using four-point Electrochemical Impedance spectroscopy (EIS for different flow rates and concentrations. The total cell resistance consists of contributions from different components: the membrane (Rmem, anode charge transfer (RA, cathode charge transfer (RC, and ion diffusion in the porous electrodes (RD.The intrinsic membrane properties of Nafion 117 has been investigated experimentally in LiI/I2 solutions with concentrations ranging between 0.06 and 0.96 M and used to identify the preferred LiI/I2 solution concentration. This was achieved by measuring the solution uptake, internal solution concentration and ion exchange capacity. The membrane properties were further used to calculate the transport coefficients and electrokinetic Figure of merit in terms of the Uniform potential and Space charge models. Special attention has been put on the streaming potential coefficient which is an intrinsic property. Keywords: Electrokinetic energy conversion, Electrochemical flow cell, Conversion efficiency

  7. Synchrotron radiation-based Mössbauer spectra of {sup 174}Yb measured with internal conversion electrons

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Ryo, E-mail: masudar@rri.kyoto-u.ac.jp; Kobayashi, Yasuhiro; Kitao, Shinji; Kurokuzu, Masayuki [Research Reactor Institute, Kyoto University, Kumatori-cho, Sennan-gun, Osaka 590-0494 (Japan); Saito, Makina [Beamline Spectroscopy/Scattering Group, Elettra-Sincrotrone Trieste, S. S. 14 Km 163.5, I-34149 Trieste (Italy); Yoda, Yoshitaka [Research and Utilization Division, Japan Synchrotron Radiation Research Institute, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Mitsui, Takaya [Condensed Matter Science Division, Japan Atomic Energy Agency, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Iga, Fumitoshi [College of Science, Ibaraki University, Mito, Ibaraki, 310-8512 (Japan); Seto, Makoto [Research Reactor Institute, Kyoto University, Kumatori-cho, Sennan-gun, Osaka 590-0494 (Japan); Condensed Matter Science Division, Japan Atomic Energy Agency, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)

    2014-02-24

    A detection system for synchrotron-radiation (SR)-based Mössbauer spectroscopy was developed to enhance the nuclear resonant scattering counting rate and thus increase the available nuclides. In the system, a windowless avalanche photodiode (APD) detector was combined with a vacuum cryostat to detect the internal conversion (IC) electrons and fluorescent X-rays accompanied by nuclear de-excitation. As a feasibility study, the SR-based Mössbauer spectrum using the 76.5 keV level of {sup 174}Yb was observed without {sup 174}Yb enrichment of the samples. The counting rate was five times higher than that of our previous system, and the spectrum was obtained within 10 h. This result shows that nuclear resonance events can be more efficiently detected by counting IC electrons for nuclides with high IC coefficients. Furthermore, the windowless detection system enables us to place the sample closer to the APD elements and is advantageous for nuclear resonant inelastic scattering measurements. Therefore, this detection system can not only increase the number of nuclides accessible in SR-based Mössbauer spectroscopy but also allows the nuclear resonant inelastic scattering measurements of small single crystals or enzymes with dilute probe nuclides that are difficult to measure with the previous detection system.

  8. HEU core conversion of Russian production reactors: a major threat to the international RERTR regime

    International Nuclear Information System (INIS)

    Kuperman, Alan J.; Leventhal, Paul L.

    1998-01-01

    This paper calls the attention for the major threat to the International Reduced Enrichment for Research and Test Reactors (RERTR) program, represented by the HEU core conversion of russian production reactors. This program aims to reduce and eventually eliminate international civilian commerce in nuclear weapons-usable, highly enriched uranium , and thereby significantly lower risks of the material being stolen or diverted by terrorist or states for producing nuclear weapons

  9. Experimental determination of beam quality conversion factors kQ in clinical photon beams using ferrous sulphate (Fricke) dosimetry

    International Nuclear Information System (INIS)

    Palm, A.; Mattsson, Olof

    2002-01-01

    The implementation of protocols based on absorbed dose to water standards requires beam quality conversion factors, k Q . Calculated values of k Q are available for ionization chambers used for reference dosimetry. Ideally, k Q should be experimentally determined at the same beam qualities as that of the user. In this work we measure k Q factors in clinical photon beams and compare them with calculated and measured values. Beam quality conversion factors are determined for clinical photon beams of nominal energies 4 MV, 6 MV, 15 MV, and 25 MV, for commonly used cylindrical ionization chambers. Twelve chambers of eight different types are used. For three of them, no experimental data have previously been available. The experimental procedure is based on measurements with ionization chambers and Fricke dosimetry in the reference beam ( 60 Co γ radiation) and in clinical linear accelerator beams. The k Q values determined in this work generally agree within 0.5% with previously reported experimental values both when %dd(10) x and TPR 20,10 are used for beam quality specification. The agreement with calculated data is generally within 0.5%, except for the 15 MV beam. For this beam the measured values are usually between 0.5% and 1% lower than the data taken from the TG-51 protocol or the TRS-398 code of practice. For three NE2571 chambers and three NE2581 chambers, the maximum observed deviation of individual k Q values is 0.2% and 0.4%, respectively

  10. X-ray diffraction measurement of the linear thermal expansion coefficients of WCoB in the range 300 to 973 K

    International Nuclear Information System (INIS)

    Petrov, K.; Will, G.

    1981-01-01

    High-temperature treatment of tungsten carbide-cobalt hard alloys in TiB 2 media leads to the formation of a surface diffusion coating which contains orthorhombic WCoB. The function of this compound in enhancing wear resistance of cutting tools, is discussed. The thermal expansion of WCoB is of primary interest, since the wear resistance of the coating reflects the degree of matching of the thermal expansion coefficients of the different phases. Preparation of the samples is described and experimental details of the X-ray diffraction measurements are given. The temperature dependence of the lattice parameters for the range 300 to 973 K, and the corresponding linear thermal expansion coefficients along the three principal crystallographic directions, are given. The results are discussed in terms of the bonding features of the solid. (U.K.)

  11. Estimation of internal heat transfer coefficients and detection of rib positions in gas turbine blades from transient surface temperature measurements

    International Nuclear Information System (INIS)

    Heidrich, P; Wolfersdorf, J v; Schmidt, S; Schnieder, M

    2008-01-01

    This paper describes a non-invasive, non-destructive, transient inverse measurement technique that allows one to determine internal heat transfer coefficients and rib positions of real gas turbine blades from outer surface temperature measurements after a sudden flow heating. The determination of internal heat transfer coefficients is important during the design process to adjust local heat transfer to spatial thermal load. The detection of rib positions is important during production to fulfill design and quality requirements. For the analysis the one-dimensional transient heat transfer problem inside of the turbine blade's wall was solved. This solution was combined with the Levenberg-Marquardt method to estimate the unknown boundary condition by an inverse technique. The method was tested with artificial data to determine uncertainties with positive results. Then experimental testing with a reference model was carried out. Based on the results, it is concluded that the presented inverse technique could be used to determine internal heat transfer coefficients and to detect rib positions of real turbine blades.

  12. Monte Carlo Method in the calculate of conversion coefficients for dose in children's organs and tissues subjected to dentistric radiography

    International Nuclear Information System (INIS)

    Loureiro, E.C.M.; Khoury, H.; Lima, F.R.A.

    1998-01-01

    The increasing utilization of oral X-rays, specially in youngsters and children, prompts the assessment of equivalent doses in their organs and tissues. With this purpose, Monte Carlo code was adopted to simulate an X-ray source irradiating phantoms of the MIRD-5 type with different ages (10, 15 and 40 years old) to calculate the conversion coefficients which transform the exposure at skin to equivalent doses at several organs and tissues of interest. In order to check the computer program, simulations were performed for adult patients using the original code (ADAM,FOR developed by GSF Germany) and the adapted program (MCDRO,PAS). Good agreement between results obtained by both programs was observed. Applications to incisive, canine and molar teeth were simulated. The conversion factors were calculated for the following organs and tissues: thyroid, active bone marrow (head and whole body), bone (facial skeleton, cranium and whole body), skin (head and whole body) and crystalline. Based on the obtained results, it follows that the younger the patient and the langer the field area, the higher the doses in assessed organs and tissues

  13. Conversion coefficients for determination of dispersed photon dose during radiotherapy: NRUrad input code for MCNP.

    Science.gov (United States)

    Shahmohammadi Beni, Mehrdad; Ng, C Y P; Krstic, D; Nikezic, D; Yu, K N

    2017-01-01

    Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient's body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5.

  14. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473 K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements

    Science.gov (United States)

    Lu, Wanjun; Guo, Huirong; Chou, I.-Ming; Burruss, R.C.; Li, Lanlan

    2013-01-01

    Accurate values of diffusion coefficients for carbon dioxide in water and brine at reservoir conditions are essential to our understanding of transport behavior of carbon dioxide in subsurface pore space. However, the experimental data are limited to conditions at low temperatures and pressures. In this study, diffusive transfer of carbon dioxide in water at pressures up to 45 MPa and temperatures from 268 to 473 K was observed within an optical capillary cell via time-dependent Raman spectroscopy. Diffusion coefficients were estimated by the least-squares method for the measured variations in carbon dioxide concentration in the cell at various sample positions and time. At the constant pressure of 20 MPa, the measured diffusion coefficients of carbon dioxide in water increase with increasing temperature from 268 to 473 K. The relationship between diffusion coefficient of carbon dioxide in water [D(CO2) in m2/s] and temperature (T in K) was derived with Speedy–Angell power-law approach as: D(CO2)=D0[T/Ts-1]m where D0 = 13.942 × 10−9 m2/s, Ts = 227.0 K, and m = 1.7094. At constant temperature, diffusion coefficients of carbon dioxide in water decrease with pressure increase. However, this pressure effect is rather small (within a few percent).

  15. Establishment of detailed eye model of adult chinese male and dose conversion coefficients calculation under neutron exposure

    International Nuclear Information System (INIS)

    Zhu, Hongyu; Qiu, Rui; Ren, Li; Zhang, Hui; Li, Junli; Wu, Zhen; Li, Chunyan

    2017-01-01

    The human eye lens is sensitive to radiation. ICRP-118 publication recommended a reduction of the occupational annual equivalent dose limit from 150 to 20 mSv, averaged over defined periods of 5 y. Therefore, it is very important to build a detailed eye model for the accurate dose assessment and radiation risk evaluation of eye lens. In this work, a detailed eye model was build based on the characteristic anatomic parameters of the Chinese adult male. This eye model includes seven main structures, which are scleral, choroid, lens, iris, cornea, vitreous body and aqueous humor. The lens was divided into sensitive volume and insensitive volume based on different cell populations. The detailed eye model was incorporated into the converted polygon-mesh version of the Chinese reference adult male whole-body surface model. After the incorporation, dose conversion coefficients for the eye lens were calculated for neutron exposure at AP, PA and LAT geometries with Geant4, the neutron energies were from 0.001 eV to 10 MeV. The calculated lens dose coefficients were compared with those of ICRP-116 publication. Significant differences up to 97.47% were found at PA geometry. This could mainly be attributed to the different geometry characteristic of eye model and parameters of head in different phantom between the present work and ICRP-116 publication. (authors)

  16. Correlation coefficients in neutron β-decay

    International Nuclear Information System (INIS)

    Byrne, J.

    1978-01-01

    The various angular and polarisation coefficients in neutron decay are the principal sources of information on the β-interaction. Measurements of the electron-neutrino angular correlation coefficient (a), the neutron-spin-electron-momentum correlation coefficient (A), the neutron-spin-neutrino-momentum correlation coefficient (B), and the triple correlation coefficient D and time-reversal invariance are reviewed and the results discussed. (U.K.)

  17. Absolute E3 and M2 transition probabilities for the electromagnetic decay of the I{sup {pi}}=K{sup {pi}}=8{sup -} isomeric state in {sup 132}Ce

    Energy Technology Data Exchange (ETDEWEB)

    Perkowski, J.; Andrzejewski, J.; Krol, A. [University of Lodz, Faculty of Physics and Applied Informatics, Lodz (Poland); Srebrny, J.; Kownacki, J.; Zielinska, M. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); Bruce, A.M. [University of Brighton, School of Environment and Technology, Brighton (United Kingdom); Droste, C.; Grodner, E.; Morek, T. [University of Warsaw, Nuclear Physics Division, IEP, Warsaw (Poland); Kisielinski, M. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); The Andrzej Soltan Institute for Nuclear Studies, Warsaw (Poland); Korman, A. [The Andrzej Soltan Institute for Nuclear Studies, Warsaw (Poland); Kowalczyk, M.; Mierzejewski, J. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); University of Warsaw, Nuclear Physics Division, IEP, Warsaw (Poland); Marganiec, J. [University of Lodz, Faculty of Physics and Applied Informatics, Lodz (Poland); Gesellschaft fuer Schwerionenforschung (GSI), Reactions and Nuclear Astrophysics Division, Darmstadt (Germany); Sobczak, K. [University of Lodz, Faculty of Physics and Applied Informatics, Lodz (Poland); Institute of Physics Polish Academy of Sciences, Warsaw (Poland); Trzaska, W.H. [University of Jyvaeskylae, Department of Physics, Survontie 9, P.O. Box 35, Jyvaeskylae (Finland); Helsinki Institute of Physics, Survontie 9, P.O. Box 35, Helsinki (Finland)

    2009-12-15

    The decay of the I{sup {pi}}=K{sup {pi}}=8{sup -} isomeric state at 2340keV in {sup 132}Ce has been investigated in the {sup 120}Sn({sup 16}O,4n){sup 132}Ce reaction. The measurements were carried out in e-{gamma} and {gamma}-{gamma} coincidence modes using an electron spectrometer coupled to the OSIRIS II gamma-ray array at the Heavy Ion Laboratory of the University of Warsaw. Experimentally obtained internal conversion coefficients for the 8{sup -}{yields}6{sup +} and 8{sup -}{yields}5{sup +} transitions allowed the multipolarities, mixing ratios, reduced transition probabilities and hindrance factors to be determined. (orig.)

  18. Model of a Generic Natural Uranium Conversion Plant ? Suggested Measures to Strengthen International Safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Raffo-Caiado, Ana Claudia [ORNL; Begovich, John M [ORNL; Ferrada, Juan J [ORNL

    2009-11-01

    This is the final report that closed a joint collaboration effort between DOE and the National Nuclear Energy Commission of Brazil (CNEN). In 2005, DOE and CNEN started a collaborative effort to evaluate measures that can strengthen the effectiveness of international safeguards at a natural uranium conversion plant (NUCP). The work was performed by DOE s Oak Ridge National Laboratory and CNEN. A generic model of a NUCP was developed and typical processing steps were defined. Advanced instrumentation and techniques for verification purposes were identified and investigated. The scope of the work was triggered by the International Atomic Energy Agency s 2003 revised policy concerning the starting point of safeguards at uranium conversion facilities. Prior to this policy only the final products of the uranium conversion plant were considered to be of composition and purity suitable for use in the nuclear fuel cycle and therefore, subject to the IAEA safeguards control. DOE and CNEN have explored options for implementing the IAEA policy, although Brazil understands that the new policy established by the IAEA is beyond the framework of the Quadripartite Agreement of which it is one of the parties, together with Argentina, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) and the IAEA. Two technical papers on this subject were published at the 2005 and 2008 INMM Annual Meetings.

  19. Conserving Coherence and Storing Energy during Internal Conversion: Photoinduced Dynamics of cis- and trans-Azobenzene Radical Cations

    KAUST Repository

    Munkerup, Kristin

    2017-10-24

    Light harvesting via energy storage in azobenzene has been a key topic for decades, and the process of energy distribution over the molecular degrees of freedom following photoexcitation remains to be understood. Dynamics of a photoexcited system can exhibit high degrees of non-ergodicity when it is driven by just a few degrees of freedom. Typically, an internal conversion leads to the loss of such localization of dynamics, as the intramolecular energy becomes statistically redistributed over all molecular degrees of freedom. Here, we present a unique case where the excitation energy remains localized even subsequent to internal conversion. Strong-field ionization is used to prepare cis- and trans-azobenzene radical cations on the D1 surface with little excess energy, at the equilibrium neutral geometry. These D1 ions are preferably formed because in this case D1 and D0 switch place in the presence of the strong laser field. The post-ionization dynamics is dictated by the potential energy landscape. The D1 surface is steep downhill along the cis/trans isomerization coordinate and towards a common minimum shared by the two isomers in the region of D1/D0 conical intersection. Coherent cis/trans torsional motion along this coordinate is manifested in the ion transients by a cosine modulation. In this scenario, D0 becomes populated with molecules that are energized mainly along the cis-trans isomerization coordinate, with the kinetic energy above the cis-trans inter-conversion barrier. These activated azobenzene molecules easily cycle back and forth along the D0 surface, and give rise to several periods of modulated signal before coherence is lost. This persistent localization of the internal energy during internal conversion is provided by the steep downhill potential energy surface, small initial internal energy content, and a strong hole-lone pair interaction that drives the molecule along the cis-trans isomerization coordinate to facilitate the transition between

  20. Temperature dependence of mode conversion in warm, unmagnetized plasmas with a linear density profile

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Dae Jung; Lee, Dong-Hun [School of Space Research, Kyung Hee University, Yongin (Korea, Republic of); Kim, Kihong [Division of Energy Systems Research, Ajou University, Suwon (Korea, Republic of)

    2013-06-15

    We study theoretically the linear mode conversion between electromagnetic waves and Langmuir waves in warm, stratified, and unmagnetized plasmas, using a numerically precise calculation based on the invariant imbedding method. We verify that the principle of reciprocity for the forward and backward mode conversion coefficients holds precisely regardless of temperature. We also find that the temperature dependence of the mode conversion coefficient is substantially stronger than that previously reported. Depending on the wave frequency and the incident angle, the mode conversion coefficient is found to increase or decrease with the increase of temperature.

  1. Measurement of X-ray attenuation coefficients around K-absorption edges using Fe Kα X-rays

    International Nuclear Information System (INIS)

    Kerur, B.R.; Thontadarya, S.R.; Hanumaiah, B.

    1993-01-01

    The x-ray mass attenuation coefficients were measured around the K-absorption edges of elements in the range 16 ≤ Z ≤ 30 using Fe Kα x-rays of energy 6.400 keV, which is the weighted average energy of Kα 1 and Kα 2 x-ray components from the 57 Co radioactive source. Kβ x-rays were almost eliminated by the differential absorption technique. The small difference in energy between Kα 1 and Kα 2 , 13 eV, was shown to be inconsequential by comparing the measured and theoretical values of μ/ρ for standard materials such as Al, Cu, Mo and Ta. The effect of fine structure of the K-absorption edge on μ/ρ was elucidated by using the compounds of elements in the range 16 ≤ X ≤ 30, containing one element with its K-absorption edge energy (E k ) close to the incident photon energy (E x ). The results clearly indicate the validity of the theoretical mixture rule for all those compounds whose K edge is far away from the incident energy but show deviations of as much as 10% for the manganese compound whose K edge is 140 eV above E x and about 12% for the chromium compound whose K edge is 410 eV below E x . These deviations are attributed to the possible influence of resonance Raman scattering when the incident photon energy E x is less than the edge and to the influence of EXAFS when E x is more than the edge energy. (Author)

  2. Determination of infinite dilution activity coefficients using HS-SPME/GC/FID for hydrocarbons in furfural at temperatures of (298.15, 308.15, and 318.15) K

    International Nuclear Information System (INIS)

    Arantes Furtado, Filipe; Vieira Coelho, Gerson Luiz

    2012-01-01

    Highlights: ► Two approaches were proposed using SPME on determination of infinite dilution activity coefficients. ► Infinite dilution activity coefficients of nine solutes in solvent furfural at T = (298.15, 308.15, and 318.15) K. ► Fiber–gas partition coefficients of nine solutes on PDMS at T = (298.15, 308.15, and 318.15) K. ► Optical microscopy analysis and statistical tests to measure possible damages on fiber coating. ► Advantages and limitations of methodology proposed were discussed. - Abstract: A new methodology using the headspace solid phase microextraction (HS-SPME) technique has been used to evaluate the infinite dilution activity coefficient (γ 12 ∞ ) of nine hydrocarbons (alkanes, cycloalkanes, and aromatics) in furfural solvent. The main objective of this study was to validate a faster and lower cost methodology expanding the use of HS-SPME to determine infinite dilution activity of solutes in organic solvents. Two approaches were proposed for the determination of γ 12 ∞ in order to use this technique (HS-SPME). In addition, the fiber–gas partition coefficients (K fg ) for each analyte at each of the studied temperatures were determined. The activity and partition coefficients have been reported at temperatures of (298.15, 308.15, and 318.15) K. The data were compared with the literature infinite dilution data determined by other methods such as liquid–gas chromatography (GLC) and gas stripping. Partial molar excess enthalpies of mixing at infinite dilution for each solute have been determined. The fibers were tested before and after each experiment, using statistical methods to ensure that their properties do not change during the experiments. The fibers were also analyzed by optical microscopy to evaluate possible surface damage by comparing them with new fibers. The activity coefficient values correlated well with the data in the literature and showed average deviations less than 10%.

  3. Anomalous field dependence of the Sommerfeld coefficient in the isotropic (K,Ba)BiO{sub 3} superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Klein, T.; Marcenat, C.; Bouquet, F.; Junod, A.; Blanchard, S.; Marcus, J

    2004-08-01

    We report on specific heat measurements in high quality (K,Ba)BiO{sub 3} single crystals (T{sub c}{approx}31.5 K). A well defined specific heat jump is clearly visible at T{sub C{sub p(H)}} in the entire investigated field range (up to 13 T). However, the corresponding T{sub C{sub p(H)}} exhibits an anomalous positive curvature and the amplitude of the jump rapidly decreases with field suggesting a non-linear increase of the Sommerfeld coefficient ({gamma}(H)). This anomalous behaviour is confirmed by low temperature measurements which show that {gamma}(H){proportional_to}H{sup {alpha}} with {alpha}{approx}0.65.

  4. Studies of highly ionized atoms using internal conversion: 197Au, 57Fe; electric monopole transitions in 40Ca, 42Ca, and 44Ca

    International Nuclear Information System (INIS)

    Ulrickson, M.A.

    1975-01-01

    By using heavy-ion reactions, highly ionized electronic states of atoms may be produced. The interaction between excited nuclear levels and the surrounding atomic electrons via internal conversion allows the nucleus to be used as a probe of the electronic structure of the highly ionized atoms. Studies of such atoms were undertaken for strongly internally converted nuclear levels in 197 Au and 57 Fe. The nuclear levels were Coulomb excited by using 16 O and 32 S beams. Simultaneous measurement of the lifetime of the 77-keV state of 197 Au in both neutral gold atoms and gold atoms with mean charge +10 resulted in a measured change in the internal conversion coefficient of Δalpha/alpha equals - 1.7 +- 3.0)10 -3 . This result is consistent with calculations using a Hartree-Fock--Slater program. Measurements of the electric monopole strengths for 0 + → 0 + transitions were undertaken to determine the amount of core-deformation in calcium nuclei. The E0 strengths for the decays of the 0 + states at 5.21 MeV in 40 C, 1.84 MeV in 42 Ca, and 1.88 MeV in 44 Ca were observed. The branching ratios for the subsequent E0 pair decays were measured by observing the coincident annihilation radiation from the e + member of the pair in coincidence with protons feeding the state in the cases of 42 Ca and 44 Ca, and by observing the actual coincident e + --e - pair together with protons feeding the state in the case of 40 Ca. The resulting E0 strengths (rho less than or equal to 0.06, rho = 0.34 +- 0.03, rho = 0.30 +- 0.10 for 40 Ca, 42 Ca, and 44 Ca respectively) agree with theoretical descriptions

  5. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  6. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  7. Linear thermal expansion coefficient (at temperatures from 130 to 800 K) of borosilicate glasses applicable for coupling with silicon in microelectronics

    OpenAIRE

    Sinev, Leonid S.; Petrov, Ivan D.

    2017-01-01

    Processing results of measurements of linear thermal expansion coefficients and linear thermal expansion of two brands of borosilicate glasses --- LK5 and Borofloat 33 --- are presented. The linear thermal expansion of glass samples have been determined in the temperature range 130 to 800 K (minus 143 to 526 $\\deg$C) using thermomechanical analyzer TMA7100. Relative imprecision of indirectly measured linear thermal expansion coefficients and linear thermal expansion of both glass brands is le...

  8. Choosing a language in international office service encounters

    DEFF Research Database (Denmark)

    Hazel, Spencer

    Choosing a language in international office service encounters – from multilingual miscellany to medium-of-interaction in a matter of seconds Spencer Hazel Roskilde University, Denmark In higher education settings characterized by increasing transnational student and staff mobility, members...... to a multimodal interaction analysis following the ethnomethodological tradition of Conversation Analysis. Gafaranga, J. (2000). Medium repair vs. other-language repair: Telling the medium of a bilingual conversation. International Journal of Bilingualism, 4(3), 327-350. Hall, J. K., Hellermann, J., & Pekarek...... Preisler (eds.) Language alternation, language choice and language encounter in international education. Dordrecht: Springer Preisler, Bent, Ida Klitgård, and Anne H. Fabricius. (2011). Language and learning in the international university: from English uniformity to diversity and hybridity. Bristol...

  9. Monte Carlo calculations of kQ, the beam quality conversion factor

    International Nuclear Information System (INIS)

    Muir, B. R.; Rogers, D. W. O.

    2010-01-01

    Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k Q , for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k Q . These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs c hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k Q is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k Q factors as a function of beam quality expressed as %dd(10) x and TPR 10 20 are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k Q values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k Q directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more

  10. On L^1-Convergence Of Rees-Stanojević's Sums With Coefficients From The Class K

    Directory of Open Access Journals (Sweden)

    Xhevat Z. Krasniqi

    2010-12-01

    Full Text Available In this paper are considered the modified cosine sums introduced by Rees and Stanojević  with coefficients from the class K. In addition, it is proved that the condition $\\lim_{n\\to \\infty}|a_{n+1}|\\log n= 0$ is a necessary and sufficient condition for the $L^{1}$-convergence of the cosine series. Also, an open problem about $L^{1}$-convergence for the $r-th$ derivative  of the cosine series is presented.

  11. Recent developments in biokinetic models and the calculation of internal dose coefficients

    International Nuclear Information System (INIS)

    Fell, T.P.; Phipps, A.W.; Kendall, G.M.; Stradling, G.N.

    1997-01-01

    In most cases the measurement of radioactivity in an environmental or biological sample will be followed by some estimation of dose and possibly risk, either to a population or an individual. This will normally involve the use of a dose coefficient (dose per unit intake value) taken from a compendium. In recent years the calculation of dose coefficients has seen many developments in both biokinetic modelling and computational capabilities. ICRP has recommended new models for the respiratory tract and for the systemic behavior of many of the more important elements. As well as this, a general age-dependent calculation method has been developed which involves an effectively continuous variation of both biokinetic and dosimetric parameters, facilitating more realistic estimation of doses to young people. These new developments were used in work for recent ICRP, IAEA and CEC compendia of dose coefficients for both members of the public (including children) and workers. This paper presents a general overview of the method of calculation of internal doses with particular reference to the actinides. Some of the implications for dose coefficients of the new models are discussed. For example it is shown that compared with data in ICRP Publications 30 and 54: the new respiratory tract model generally predicts lower deposition in systemic tissues per unit intake; the new biokinetic models for actinides allow for burial of material deposited on bone surfaces; age-dependent models generally feature faster turnover of material in young people. All of these factors can lead to substantially different estimates of dose and examples of the new dose coefficients are given to illustrate these differences. During the development of the new models for actinides, human bioassay data were used to validate the model. Thus, one would expect the new models to give reasonable predictions of bioassay quantities. Some examples of the bioassay applications, e.g., excretion data for the

  12. An International Standard Equation of State for Difluoromethane (R-32) for Temperatures from the Triple Point at 136.34 K to 435 K and Pressures up to 70 MPa

    International Nuclear Information System (INIS)

    Tillner-Roth, R.; Yokozeki, A.

    1997-01-01

    A fundamental equation of state for the Helmholtz free energy of R-32 (difluoromethane) is presented which is valid from the triple point at 136.34 K to 435 K and pressures up to 70 MPa. It is based on accurate measurements of pressure-density-temperature (p,ρ,T), speed of sound, heat capacity, and vapor pressure currently available. New values for the isobaric heat capacity c p circ of the ideal gas calculated from spectroscopic data taking into account also first order anharmonicity corrections are presented. The Helmholtz free energy equation of state has 19 coefficients and represents all selected experimental data within their estimated accuracy with the exception for heat capacities and speed of sound in the region close to the critical point. Typical uncertainties are ±0.05% for density, ±0.02% for the vapor pressure and ±0.5%endash 1% for the heat capacity. This equation of state has been compared to equations developed by other research groups by Annex 18 of the International Energy Agency and has been selected as an international standard formulation for the thermodynamic properties of R-32 by this group. copyright 1997 American Institute of Physics and American Chemical Society

  13. Fuel conversion efficiency and energy balance of a 400 kW{sub t} fluidized bed straw gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Erguedenler, A.; Ghaly, A.E.; Hamdullahpur, F. [Technical Univ. of Nova Scotia, Halifax (Canada)

    1993-12-31

    A 400 kW (thermal) dual-distributor type fluidized bed gasifier developed for the energy recovery from cereal straw was used to investigate the effects of equivalence ratio (actual air-fuel ratio: stoichiometric air-fuel ratio), fluidization velocity and bed height on the fuel conversion efficiency from wheat straw. The energy balance was also performed on the system under those operating conditions. The results indicated that the equivalence ratio was the most significant parameter affecting the fuel conversion efficiency and the energy recovered from the straw in the form of gas. Both the fuel conversion efficiency and the energy recovery increased with increases in the equivalence ratio. The fluidization velocity and bed height had minimal effects on these parameters. A fuel conversion efficiency as high as 98% was obtained at the equivalence ratio of 0.35. The energy recovered in the form of gas and the sensible heat of the produced gas were in the ranges of 40--70% and 9--17%, respectively. Unaccounted losses showed a dramatic increase at lower equivalence ratios and were in the range of 6--53% depending on the operating condition.

  14. Diffusion coefficients of the ternary system (2-hydroxypropyl-{beta}-cyclodextrin + caffeine + water) at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Ana C.F. [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal)], E-mail: anacfrib@ci.uc.pt; Santos, Cecilia I.A.V. [Departamento de Quimica Fisica, Facultad de Farmacia, Universidad de Alcala, 28871 Alcala de Henares, Madrid (Spain)], E-mail: cecilia.alves@uah.es; Lobo, Victor M.M. [Department of Chemistry, University of Coimbra, 3004-535 Coimbra (Portugal)], E-mail: vlobo@ci.uc.pt; Cabral, Ana M.T.D.P.V. [Faculty of Pharmacy, University of Coimbra, 3000-295 Coimbra (Portugal)], E-mail: acabral@ff.uc.pt; Veiga, Francisco J.B. [Faculty of Pharmacy, University of Coimbra, 3000-295 Coimbra (Portugal)], E-mail: fveiga@ci.uc.pt; Esteso, Miguel A. [Departamento de Quimica Fisica, Facultad de Farmacia, Universidad de Alcala, 28871 Alcala de Henares, Madrid (Spain)], E-mail: miguel.esteso@uah.es

    2009-12-15

    Ternary mutual diffusion coefficients measured by Taylor dispersion method (D{sub 11}, D{sub 22}, D{sub 12}, and D{sub 21}) are reported for aqueous solutions of 2-hydroxypropyl-{beta}-cyclodextrin (HP-{beta}-CD) + caffeine at T = 298.15 K at carrier concentrations from (0.000 to 0.010) mol . dm{sup -3}, for each solute, respectively. These diffusion coefficients have been measured having in mind a better understanding of the structure of these systems and thermodynamic behaviour of caffeine and 2-hydroxypropyl-{beta}-cyclodextrin in solution. For example, from these data it will be possible to estimate some parameters, such as the fraction of associated species HP-{beta}-CD (X{sub 1}) and caffeine (X{sub 2}) in this complex, the monomer and dimer fractions, X{sub 2}{sup M} and X{sub 2}{sup D}, respectively, and the limiting diffusion coefficients of the HP-{beta}-CD, D{sub HPBCD}{sup 0}, of the dimers caffeine entities, D{sub D}{sup 0}, and of those complexes (1:1), D{sub complex}{sup 0}.

  15. Quantum-dynamical Modeling of the Rydberg to Valence Excited-State Internal Conversion in Cyclobutanone and Cyclopentanone

    DEFF Research Database (Denmark)

    Kuhlman, T. S.; Sauer, Stephan P. A.; Solling, T. I.

    2013-01-01

    In this paper we present 4-state, 5-dimensional Vibronic Coupling Hamiltonians for cyclobutanone and cyclopentanone. Wave packet calculations using these Hamiltonians reveal that for cyclobutanone the (n,3s) to (n,π*) internal conversion involves direct motion in nuclear modes coupling the two st...... states leading to fast population transfer. For cyclopentanone, internal vibrational energy redistribution is a bottleneck for activating reactive nuclear modes leading to slower population transfer....

  16. ESTABLISHMENT OF DETAILED EYE MODEL OF ADULT CHINESE MALE AND DOSE CONVERSION COEFFICIENTS CALCULATION UNDER NEUTRON EXPOSURE.

    Science.gov (United States)

    Zhu, Hongyu; Qiu, Rui; Wu, Zhen; Ren, Li; Li, Chunyan; Zhang, Hui; Li, Junli

    2017-12-01

    The human eye lens is sensitive to radiation. ICRP-118 publication recommended a reduction of the occupational annual equivalent dose limit from 150 to 20 mSv, averaged over defined periods of 5 y. Therefore, it is very important to build a detailed eye model for the accurate dose assessment and radiation risk evaluation of eye lens. In this work, a detailed eye model was build based on the characteristic anatomic parameters of the Chinese adult male. This eye model includes seven main structures, which are scleral, choroid, lens, iris, cornea, vitreous body and aqueous humor. The lens was divided into sensitive volume and insensitive volume based on different cell populations. The detailed eye model was incorporated into the converted polygon-mesh version of the Chinese reference adult male whole-body surface model. After the incorporation, dose conversion coefficients for the eye lens were calculated for neutron exposure at AP, PA and LAT geometries with Geant4, the neutron energies were from 0.001 eV to 10 MeV. The calculated lens dose coefficients were compared with those of ICRP-116 publication. Significant differences up to 97.47% were found at PA geometry. This could mainly be attributed to the different geometry characteristic of eye model and parameters of head in different phantom between the present work and ICRP-116 publication. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Determination of solid-liquid partition coefficients (K{sub d}) for the herbicides inspiration and trifluralin in five UK agricultural soils

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, Cindy M. [Department of Environmental Science and Technology, Faculty of Life Sciences, Imperial College London, Silwood Park Campus, Ascot, Berkshire SL5 7PY (United Kingdom)]. E-mail: cindy.cooke@imperial.ac.uk; Shaw, George [Department of Environmental Science and Technology, Faculty of Life Sciences, Imperial College London, Silwood Park Campus, Ascot, Berkshire SL5 7PY (United Kingdom); Collins, Chris D. [Department of Environmental Science and Technology, Faculty of Life Sciences, Imperial College London, Silwood Park Campus, Ascot, Berkshire SL5 7PY (United Kingdom)

    2004-12-01

    Isoproturon and trifluralin are herbicides of contrasting chemical characters and modes of action. Standard batch sorption procedures were carried out to investigate the individual sorption behaviour of {sup 14}C-isoproturon and {sup 14}C-trifluralin in five agricultural soils (1.8-4.2% OC), and the soil solid-liquid partition coefficients (K{sub d} values) were determined. Trifluralin exhibited strong partitioning to the soil solid phase (K{sub d} range 106-294) and low desorption potential, thus should not pose a threat to sensitive waters via leaching, although particle erosion and preferential flow pathways may facilitate transport. For isoproturon, soil adsorption was low (K{sub d} range 1.96-5.75) and desorption was high, suggesting a high leaching potential, consistent with isoproturon being the most frequently found pesticide in UK surface waters. Soil partitioning was directly related to soil organic carbon (OC) content. Accumulation isotherms were modelled using a dual-phase adsorption model to estimate adsorption and desorption rate coefficients. Associations between herbicides and soil humic substances were also shown using gel filtration chromatography. - Capsule: Herbicide soil sorption described by a dual-phase adsorption model reflected soil partitioning, as influenced by soil OC and humic substances.

  18. On the reliability of the theoretical internal conversion coefficients

    Czech Academy of Sciences Publication Activity Database

    Ryšavý, Miloš; Dragoun, Otokar

    2000-01-01

    Roč. 26, - (2000), s. 1859-1872 ISSN 0954-3899 R&D Projects: GA ČR GA202/00/1625; GA AV ČR KSK1048601 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.284, year: 2000

  19. Investigation of internal conversion electron lines by track counting technique

    CERN Document Server

    Islamov, T A; Kambarova, N T; Muminov, T M; Lebedev, N A; Solnyshkin, A A; Aleshin, Yu D; Kolesnikov, V V; Silaev, V I; Niipf-Tashgu, T

    2001-01-01

    The methodology of counting the tracks of the internal conversion electron (ICE) in the nuclear photoemulsion is described. The results on counting the ICE tracks on the photoplates for sup 1 sup 6 sup 1 Ho, sup 1 sup 6 sup 3 Tm, sup 1 sup 6 sup 6 Tm, sup 1 sup 3 sup 5 Ce is described. The above results are obtained through the MBI-9 microscope and the MAS-1 automated facility. The ICE track counting on the photoplates provides for essentially higher sensitivity as compared to the photometry method. This makes it possible to carry out measurements with the sources by 1000 times weaker as by the study into the density of blackening

  20. Measuring localization and diffusion coefficients of basolateral proteins in lateral versus basal membranes using functionalized substrates and kICS analysis

    DEFF Research Database (Denmark)

    Marlar, Saw; Christensen, Eva Arnspang; Pedersen, Gitte Albinus

    2014-01-01

    Micropatterning enabled semiquantitation of basolateral proteins in lateral and basal membranes of the same cell. Lateral diffusion coefficients of basolateral aquaporin-3 (AQP3-EGFP) and EGFP-AQP4 were extracted from “lateral” and “basal” membranes using identical live-cell imaging and k...

  1. 76 FR 35259 - Samaritan Pharmaceuticals, Inc., Seaena, Inc., Seirios International, Inc. (f/k/a Exactly...

    Science.gov (United States)

    2011-06-16

    ...., Seirios International, Inc. (f/k/a Exactly Sportswear, Inc.), et al.; Order of Suspension of Trading June... Sportswear, Inc.), Sento Corp., Shoe Pavilion, Inc., Silver Eagle Resources Ltd. (n/k/a Mercator Minerals Ltd... concerning the securities of Seirios International, Inc. (f/k/a Exactly Sportswear, Inc.) because it has not...

  2. Experimental Investigation from the Operation of a 2 kW Brayton Power Conversion Unit and a Xenon Ion Thruster

    Science.gov (United States)

    Hervol, David; Mason, Lee; Birchenough, Art; Pinero, Luis

    2004-01-01

    A 2kW Brayton Power Conversion Unit (PCU) and a xenon ion thruster were integrated with a Power Management and Distribution (PMAD) system as part of a Nuclear Electric Propulsion (NEP) Testbed at NASA's Glenn Research Center. Brayton Converters and ion thrusters are potential candidates for use on future high power NEP mission such as the proposed Jupiter Icy Moons Orbiter (JIMO). The use of a existing lower power test hardware provided a cost effective means to investigate the critical electrical interface between the power conversion system and the propulsion system. The testing successfully demonstrated compatible electrical operations between the converter and the thruster, including end-to-end electric power throughput, high efficiency AC to DC conversion, and thruster recycle fault protection. The details of this demonstration are reported herein.

  3. Total conversion coefficient of the 263 keV (21/sup 2//2->13/sup +//2) transition in sup(93m)Mo

    Energy Technology Data Exchange (ETDEWEB)

    Suryanaryana, C.; Venkateswara Rao, M.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1985-01-01

    The total conversion coefficient of the 263 keV gamma transition in the decay scheme of sup(93m)Mo is measured by intensity balance method using a HP Ge spectrometer system. The experimental value of ..cap alpha..sub(T)(263 keV) is found to be 0.696 +- 0.05 which is in agreement with the theoretical values 0.72 and 0.7. The transition probability T(E4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate. A good agreement is noted between the theory and the experiment for the value of T(E4).

  4. Quantum-dynamical Modeling of the Rydberg to Valence Excited-State Internal Conversion in Cyclobutanone and Cyclopentanone

    Directory of Open Access Journals (Sweden)

    Møller K. B.

    2013-03-01

    Full Text Available In this paper we present 4-state, 5-dimensional Vibronic Coupling Hamiltonians for cyclobutanone and cyclopentanone. Wave packet calculations using these Hamiltonians reveal that for cyclobutanone the (n,3s to (n,π* internal conversion involves direct motion in nuclear modes coupling the two states leading to fast population transfer. For cyclopentanone, internal vibrational energy redistribution is a bottleneck for activating reactive nuclear modes leading to slower population transfer.

  5. A new magnetic spectrometer for the investigation of the internal conversion electron in capture reaction

    International Nuclear Information System (INIS)

    Suarez, A.A.

    1978-01-01

    Planning, development and manufacture of a new beta spectrometer for the investigation of the internal conversion electrons, from 0,02 to 10 MeV, emitted during the radioative capture process of the thermal neutrons. The resolution on the base of resolution curve is about 1,5 X 10 sup(-3) [pt

  6. Activity coefficients of NaF in (glucose+water) and (sucrose+water) mixtures at 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Luis, Felipe [Departamento de Quimica Fisica, Universidad de La Laguna, Tenerife (Spain)]. E-mail: ffhelu@ull.es; Galleguillos, Hector R. [Departamento de Ingenieria Quimica, Universidad de Antofagasta, Antofagasta (Chile); Vazquez, Mario V. [Instituto de Quimica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia, Medellin (Colombia)

    2004-11-01

    The activity coefficients of NaF in (glucose+water) and (sucrose+water) mixtures were experimentally determined at 298.15 K from electromotive force measurements of the following electrochemical cell containing two ion selective electrodes (ISEs):Na-ISE|NaF(m),sugar(Y),H2O(100-Y)|F-ISEThe molality (m) varied between ca. 0.01 mol.kg{sup -1} and saturation, while the mass fractions of sugar in the mixture (Y) were 0, 0.10, 0.20, 0.30 and 0.40. The values for electromotive force were analyzed using different models for describing the variations of the activity coefficients with concentration, including an extended Debye-Huckel, the Pitzer and the Scatchard equations. Results obtained with the different models were in good agreement. Once E{sup -}bar was determined, the mean coefficients of ionic activity for NaF, the free energy of transference from the water to the (sugar+water) mixture, and the primary NaF hydration number were calculated. The variation of these magnitudes with the composition of the mixture is comparative discussed in terms of the ion-solvent and ion-ion interactions with results from the literature for NaCl in (glucose+water) and (sucrose+water) systems.

  7. Activity coefficients of plutonium and cerium in liquid gallium at 1073 K: Application to a molten salt/solvent metal separation concept

    International Nuclear Information System (INIS)

    Lambertin, David; Ched'homme, Severine; Bourges, Gilles; Sanchez, Sylvie; Picard, Gerard S.

    2005-01-01

    Activity coefficients in liquid metal and salt phases are important parameters for predicting the separation efficiency of reductive extraction or electrochemical pyrochemical processes. The electrochemical properties of Ce and Pu in gallium metal and chlorides media - CaCl 2 and equimolar NaCl-KCl - have been studied at 1073 K. Cyclic voltammetry and chronoamperometry show the thermodynamic feasibility of using gallium as solvent metal for pyrochemical processes involving Pu and Ce. The activity coefficient of Pu in liquid Ga (log(γ Pu,Ga ) = -7.3 ± 0.5) is deduced from the results and is a basis of assessing the potential for using liquid metals in pyrochemical separation of actinides and lanthanides. Evaluation of literature data for Al, Bi and Cd suggests that Ga is most favorable for selective separation of Pu from Ce near 1073 K

  8. A new fifth parameter for transverse isotropy III: reflection and transmission coefficients

    Science.gov (United States)

    Kawakatsu, Hitoshi

    2018-04-01

    The effect of the newly defined fifth parameter, ηκ, of transverse anisotropy to the reflection and transmission coefficients, especially for P-to-S and S-to-P conversion coefficients, is examined. While ηκ systematically affects the P-to-S and S-to-P conversions, in the incidence angle range of the practical interest of receiver function studies, the effect may be asymmetric in a sense that P-wave receiver function is affected more than S-receiver function in terms of amplitude. This asymmetry may help resolving ηκ via extensive receiver function analysis. It is also found that P-wave anisotropy significantly influences P-to-S and S-to-P conversion coefficients that complicates the interpretation of receiver functions, because, for isotropic media, we typically attribute the primary receiver function signals to S-wave velocity changes but not to P-wave changes.

  9. Measurement of Soret coefficients in a ternary mixture of toluene-methanol-cyclohexane in convection-free environment

    Science.gov (United States)

    Mialdun, A.; Ryzhkov, I.; Khlybov, O.; Lyubimova, T.; Shevtsova, V.

    2018-01-01

    We report on the measurement of Soret (ST) coefficients in the ternary system toluene (T)-methanol (M)-cyclohexane (Ch) onboard the International Space Station in the experiment selectable optical diagnostic instrument/DCMIX2 (Diffusion Coefficients Measurement in ternary mIXtures). Nine experiments were conducted in the range of mean temperatures between 298.15 K and 306.15 K in the mixture with composition 0.62 (T)-0.31 (M)-0.07 (Ch) in mass fractions. A linear dependence of the Soret coefficients on temperature was established for the ternary mixture. It has also been found that, over considered range of mean temperatures, the Soret coefficients of toluene are small and positive, while the Soret coefficients for methanol are negative and, at least, two times larger. The present work also presents a comprehensive study of possible methodologies to process raw data from the Soret experiment in ternary mixtures. All the experiments were processed by seven different schemes and two of them were identified as the most reliable. We also investigate the error propagation and explain the reasons for the discrepancy of the results obtained by different schemes.

  10. Development of a 3 kW double-acting thermoacoustic Stirling electric generator

    International Nuclear Information System (INIS)

    Wu, Zhanghua; Yu, Guoyao; Zhang, Limin; Dai, Wei; Luo, Ercang

    2014-01-01

    Highlights: • A 3 kW double-acting thermoacoustic Stirling electric generator is introduced. • 1.57 kW electric power with 16.8% thermal-to-electric efficiency was achieved. • High mechanical damping coefficient greatly decreases the system performance. • Performance difference is significant, which also decreased system performance. - Abstract: In this paper, a double-acting thermoacoustic Stirling electric generator is proposed as a new device capable of converting external heat into electric power. In the system, at least three thermoacoustic Stirling heat engines and three linear alternators are used to build a multiple-cylinder electricity generator. In comparison with the conventional thermoacoustic electricity generation system, the double-acting thermoacoustic Stirling electric generator has advantages on efficiency, power density and power capacity. In order to verify the idea, a prototype of 3 kW three-cylinder double-acting thermoacoustic Stirling electric generator is designed, built and tested. Based on the classic thermoacoustic theory, numerical simulation is performed to obtain the thermodynamic parameters of the engine. And distributions of key parameters are presented for a better understanding of the energy conversion process in the engine. In the experiments, a maximum electric power of about 1.57 kW and a maximum thermal-to-electric conversion efficiency of 16.8% were achieved with 5 MPa pressurized helium and 86 Hz working frequency. However, we find that the mechanical damping coefficient of the piston is dramatically increased due to the deformation of the cylinder wall caused by high thermal stress during the experiments. Thereby, the system performance was greatly reduced. Additionally, the performance differences between three engines and three alternators are significant, such as the heating temperature difference between three heater blocks of the engines, the piston displacement and the output electric power differences between

  11. Documentation Experiences for Jamaican SLOWPOKE-2 Conversion from HEU to LEU

    International Nuclear Information System (INIS)

    Warner, T.-A.; Dennis, H.; Antoine, J.

    2015-01-01

    The Jamaican SLOWPOKE–2 (JM–1) is a 20 kW research reactor manufactured by Atomic Energy of Canada Limited and has been operating since March 1984, in the department of the International Centre for Environmental and Nuclear Sciences (ICENS), at the University of the West Indies, Mona Campus in Kingston, Jamaica. The pool type reactor has been primarily used for Neutron Activation Analysis in environmental, agricultural, geochemical, health-related studies and mineral exploration. The University, assisted by the IAEA under the GTRI/RERTR program, is currently in the process of converting from HEU to LEU. Extensive documentation on policies, general requirements, elements of the conversion quality assurance (QA) system and conversion QA administrative procedures is required for the conversion. The core conversion activities are being carried out in accordance with current international standards and regulatory guidelines of the newly established Jamaican Radiation Safety Authority (RSA) with agreement between the RSA and IAEA or DOE related to Nuclear Safety and Control. The documentation structure has taken into consideration nuclear safety and licensing, LEU fuel design and conversion analysis, LEU fuel procurement and fabrication, removal of HEU fuel and reactor maintenance and conversion and commissioning, with the conversion QA manual at the apex of the structure. To a large extent, the documentation format will adhere to that of the IAEA applicable regulatory standards and guidance documents. The major challenge of the conversion activities, it is envisioned, will come from the absence of any previous regulatory framework in Jamaica; however, a timeline for the process, which includes training and equipping of regulators, will guide operation. (author)

  12. Nuclear spin conversion in formaldehyde

    OpenAIRE

    Chapovsky, Pavel L.

    2000-01-01

    Theoretical model of the nuclear spin conversion in formaldehyde (H2CO) has been developed. The conversion is governed by the intramolecular spin-rotation mixing of molecular ortho and para states. The rate of conversion has been found equal 1.4*10^{-4}~1/s*Torr. Temperature dependence of the spin conversion has been predicted to be weak in the wide temperature range T=200-900 K.

  13. Internal friction and lattice anomalies of single-phase Hg-1223

    International Nuclear Information System (INIS)

    Zhang, Q.M.; Nanjing Univ.; Shao, H.M.; Nanjing Univ.; Huang, Y.N.; Nanjing Univ.; Shen, H.M.; Nanjing Univ.; Wang, Y.N.; Nanjing Univ.

    1997-01-01

    Internal friction in the kHz range has been performed for single-phase HgBa 2 Ca 2 Cu 3 O 8+δ with the critical temperature T c = 120 K. The results indicate that two peaks of internal friction appear near 150 and 250 K. X-ray diffraction exhibits a lattice parameter stepping at tens of Kelvin above T c . The Grueneisen parameter γ is estimated from the value of thermal expansion coefficients obtained from X-ray diffraction measurements. The discussion suggests that the anomaly at 150 K is caused by lattice instabilities and the other one near 250 K may be associated with a Neel transition. (orig.)

  14. Rate coefficient for the reaction N + NO

    Science.gov (United States)

    Fox, J. L.

    1994-01-01

    Evidence has been advanced that the rate coefficient for the reaction N + NO right arrow N2 + O has a small positive temperature dependence at the high temperatures (900 to 1500 K) that prevail in the terrestrial middle and upper thermosphere by Siskind and Rusch (1992), and at the low temperatures (100 to 200 K) of the Martian lower thermosphere by Fox (1993). Assuming that the rate coefficient recommended by the Jet Propulsion Laboratory evaluation (DeMore et al., 1992) is accurate at 300 K, we derive here the low temperature value of the activation energy for this reaction and thus the rate coefficient that best fits the Viking 1 measured NO densities. We find that the fit is acceptable for a rate coefficient of about 1.3 x 10(exp -10)(T/300)(exp 0.5)exp(-400/T) and better for a value of about 2.5 x 10(exp -10)(T/300)(exp 0.5)exp(-600/T)cu cm/s.

  15. Comparison of effective transverse piezoelectric coefficients e31,f of Pb(Zr,Ti)O3 thin films between direct and converse piezoelectric effects

    Science.gov (United States)

    Tsujiura, Yuichi; Kawabe, Saneyuki; Kurokawa, Fumiya; Hida, Hirotaka; Kanno, Isaku

    2015-10-01

    We evaluated the effective transverse piezoelectric coefficients (e31,f) of Pb(Zr,Ti)O3 (PZT) thin films from both the direct and converse piezoelectric effects of unimorph cantilevers. (001) preferentially oriented polycrystalline PZT thin films and (001)/(100) epitaxial PZT thin films were deposited on (111)Pt/Ti/Si and (001)Pt/MgO substrates, respectively, by rf-magnetron sputtering, and their piezoelectric responses owing to intrinsic and extrinsic effects were examined. The direct and converse |e31,f| values of the polycrystalline PZT thin films were calculated as 6.4 and 11.5-15.0 C/m2, respectively, whereas those of the epitaxial PZT thin films were calculated as 3.4 and 4.6-4.8 C/m2, respectively. The large |e31,f| of the converse piezoelectric property of the polycrystalline PZT thin films is attributed to extrinsic piezoelectric effects. Furthermore, the polycrystalline PZT thin films show a clear nonlinear piezoelectric contribution, which is the same as the Rayleigh-like behavior reported in bulk PZT. In contrast, the epitaxial PZT thin films on the MgO substrate show a piezoelectric response owing to the intrinsic and linear extrinsic effects, and no nonlinear contribution was observed.

  16. Supported black phosphorus nanosheets as hydrogen-evolving photocatalyst achieving 5.4% energy conversion efficiency at 353 K.

    Science.gov (United States)

    Tian, Bin; Tian, Bining; Smith, Bethany; Scott, M C; Hua, Ruinian; Lei, Qin; Tian, Yue

    2018-04-11

    Solar-driven water splitting using powdered catalysts is considered as the most economical means for hydrogen generation. However, four-electron-driven oxidation half-reaction showing slow kinetics, accompanying with insufficient light absorption and rapid carrier combination in photocatalysts leads to low solar-to-hydrogen energy conversion efficiency. Here, we report amorphous cobalt phosphide (Co-P)-supported black phosphorus nanosheets employed as photocatalysts can simultaneously address these issues. The nanosheets exhibit robust hydrogen evolution from pure water (pH = 6.8) without bias and hole scavengers, achieving an apparent quantum efficiency of 42.55% at 430 nm and energy conversion efficiency of over 5.4% at 353 K. This photocatalytic activity is attributed to extremely efficient utilization of solar energy (~75% of solar energy) by black phosphorus nanosheets and high-carrier separation efficiency by amorphous Co-P. The hybrid material design realizes efficient solar-to-chemical energy conversion in suspension, demonstrating the potential of black phosphorus-based materials as catalysts for solar hydrogen production.

  17. Osmotic coefficients of binary mixtures of four ionic liquids with ethanol or water at T = (313.15 and 333.15) K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gonzalez, Begona; Dominguez, Angeles; Macedo, Eugenia A.

    2009-01-01

    Measurements of osmotic coefficients of BmimCl (1-butyl-3-methylimidazolium chloride) and HmimCl (1-hexyl-3-methylimidazolium chloride) with ethanol and EmimEtSO 4 (1-ethyl-3-methylimidazolium ethylsulfate) and EmpyEtSO 4 (1-ethyl-3-methylpyridinium ethylsulfate) with water at T = (313.15 and 333.15) K are reported in this work. Vapour pressure and activity results of the studied binary systems are obtained from experimental measurements. The results for the osmotic coefficients are correlated using the extended Pitzer model modified by Archer and the modified NRTL (MNRTL) model. The standard deviations obtained with both models are also given. The parameters obtained with the extended Pitzer model of Archer are used to calculate the mean molal activity coefficients

  18. International seminar on year 2000 (Y2K): Progress and co-operation. Book of extended synopses

    International Nuclear Information System (INIS)

    1999-01-01

    The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and PC hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities

  19. 7th International k0-Users' Workshop

    International Nuclear Information System (INIS)

    Borut Smodis

    2018-01-01

    Complete text of publication follows. The k 0 method of neutron activation analysis (k 0 -NAA) has become a well-established analytical tool for elemental analysis of various samples since its introduction in mid-1970s. To strengthen its development, applications and use, a series of regular workshops dedicated to this particular analytical method has been introduced twenty-five years ago, held in Astene, Belgium (1992); Ljubljana, Slovenia (1996); Bruges, Belgium (2001); Funchal, Portugal (2005); Belo Horizonte, Brazil (2009) and Budapest, Hungary (2013). The 7th k 0 -Users' Workshop was held at Hotel Novotel Montreal Centre, Canada, 3-8 September 2017. The meeting was organized by Polytechnique Montreal in cooperation with the International Atomic Energy Agency. Twenty-seven participants from 16 different countries (Australia, Austria, Belgium, Brazil, Canada, Czech Republic, Egypt, Germany, Hungary, Italy, Jamaica, Peru, Slovenia, the Netherlands, Turkey, Vietnam) from all five continents discussed the latest developments and applications of k 0 -NAA. Thirty-three papers were presented in the following sessions: Fundamentals of k 0 -NAA, Nuclear Data, Neutron Flux Parameters, k 0 -NAA Methodology, Validation of k 0 -NAA, Facilities, Automatization, and k 0 -NAA Methodology and PGAA. The talks included presentations by two Keynote Speakers and one Honorary Speaker. During the workshop, scientific visits were paid to the SLOWPOKE NAA Laboratory and Thermal Hydraulics Laboratory of the Polytechnique Montreal. The upcoming 12 papers in this issue of the Journal of Radioanalytical and Nuclear Chemistry were selected to be published from the workshop. The next, 8th k 0 -Users' Workshop is expected to be held in Ljubljana, Slovenia in 2021.

  20. Confidence bounds and hypothesis tests for normal distribution coefficients of variation

    Science.gov (United States)

    Steve Verrill; Richard A. Johnson

    2007-01-01

    For normally distributed populations, we obtain confidence bounds on a ratio of two coefficients of variation, provide a test for the equality of k coefficients of variation, and provide confidence bounds on a coefficient of variation shared by k populations.

  1. Dependence of the K x-ray energy on the mode of excitation

    International Nuclear Information System (INIS)

    Wang, K.C.; Boehm, F.; Hahn, A.A.; Vogel, P.

    1977-01-01

    The energy shifts in the Ta K x rays resulting from the K-capture of 181 W, fluorescence of Ta, and β - decay of 181 Hf followed by internal conversion in 181 Ta are reported. Both W metal and WO 3 on one hand, and Ta metal and Ta 2 O 5 on the other hand, were used. Comparison of the K x-ray energies of the K-capture sources 153 Gd (Eu x rays) and 175 Hf (Lu x rays) and the corresponding fluorescence sources was also made. Various effects which may influence the K x-ray energies are discussed. 9 references

  2. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  3. Internal dosimetry contamination: update of revision of the dose coefficients for intakes of radionuclides by workers

    International Nuclear Information System (INIS)

    Gomez Parada, I.; Rojo, A.M.; Sanguineti, R.

    1995-01-01

    ICRP publication 60 introduces new biological information related to the detriment associated with radiation exposures. The International Commission on Radiological Protection has also issued, in publications 57, 67 y 69, new biokinetic models for selected radionuclides since the issue of publication 30. In publication 66 the new human respiratory tract model for radiological protection is described. The aim of the present paper is to compare values of dose coefficients for workers calculated using the new tissue weighting factors, biokinetic models and lung model with those given in publication 30.The software package LUPED 1.1 was used to calculate dose coefficients for inhalation and ingestion. When possible, some changes in the biokinetic models were made trying to incorporate new parameters. The following radionuclides were analysed: 60 Co, 90 Sr, 99m Tc, 131 I, 137 Cs, 239 Pu y 241 Am. Most of the inhalation dose coefficients calculated with the new assumptions are within a factor of three of those calculated using the ICRP 30 lung and biokinetic models. Generally, the inhalation dose coefficients calculated with the new respiratory tract model and assuming a 5μm AMAD are lower than those calculated using the ICRP 30 model and parameters. The inhalation dose coefficients are generally within 10-90 % of the corresponding Publication 61 values, the difference tending to increase for relative insoluble compounds. (author). 10 refs., 4 tabs

  4. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models

    Science.gov (United States)

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan

    2013-12-01

    Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may

  5. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models

    International Nuclear Information System (INIS)

    Tian, Xiaoyu; Samei, Ehsan; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K

    2013-01-01

    Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI vol -normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2–180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2–80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57–180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI vol -normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDI vol

  6. Conversion of optical wave polarizations in 1D finite anisotropic photonic crystal

    International Nuclear Information System (INIS)

    Ouchani, N.; Nougaoui, N.; Daoudi, A.; Bria, D.

    2006-07-01

    We show that by using one dimensional anisotropic photonic structures, it is possible to realize optical wave polarization conversion by transmission or by reflection. Thus a single incident S(P) polarized plane wave can produce a single reflected P(S) polarized wave and a single transmitted P(S) polarized wave. This polarization conversion property can be fulfilled with a simple finite superlattice constituted by anisotropic dielectric materials. We discuss the appropriate choices of the material and geometrical properties to realize such structures. The transmission and reflection coefficients are discussed in relation with the dispersion curves of the finite structure embedded between two isotropic substrates. Both transmission and reflection coefficients are calculated in the framework of Green's function method. The amplitude and the polarization characteristics of reflected and transmitted waves are determined as function of frequency ω , and wave vector k parallel ( parallel to the interface) and the orientations of the principal axes of the layers constituting the SL. Moreover, this structure exhibits a coupling between S and P waves that does not exist in SL composed only of isotropic materials. Specific applications of these results are given for a superlattice consisting of alternating biaxial anisotropic layers NaNO 2 /SbSi sandwiched between two identical semi-infinite isotropic media. (author)

  7. FEATURES OF ELECTROMECHANICAL ACOUSTIC ENERGY CONVERSION BY CYLINDRICAL PIEZOCERAMIC TRANSDUCERS WITH INTERNAL SCREENS IN COMPOSITION OF FLAT SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. G. Leiko

    2018-01-01

    Full Text Available The problem of sound emission is considered by a system formed from cylindrical piezoceramic radiators with internal acoustically soft screens. Longitudinal axis of emitters lie in one plane. This system is characterized by the interaction of electric, mechanical and acoustic fields in the process of conversion electrical energy to acoustical energy and acoustic fields in the process of forming them in the environments. The purpose of the work is to determine the peculiarities of the electromechanical acoustic transformation of energy by cylindrical piezoceramic radiators with internal screens in the composition of flat systems, taking into account all types of interaction.The research was carried out by the method of bound fields in multiply connected domains with the use of addition theorems for the cylindrical wave functions. The physical fields arising from the emission of sound by such a system are determined by the joint solution of the system of differential equations: the wave equation; equations of motion of thin piezoceramic shells with circular polarization in displacements; the equations of forced electrostatics for piezoceramics at given boundary conditions, the conditions of conjugation of fields at the boundaries of the division of domains and electric conditions.The solution of the problem is reduced to the solution of an infinite system of linear algebraic equations with respect to unknown coefficients of field expansions.An analysis of the results of numerical calculations, performed on the basis of the obtained analytical relations, called to establish a number of features in the electromechanical acoustic transformation of energy by emitters in the composition of flat systems. They include: the role of acoustic interaction in the process of energy conversion; determination of the mechanism of quantitative assessment of the influence of interaction on these processes; the dependence of the degree of violation of the radial

  8. Development of reflectance-based crop coefficients for corn

    International Nuclear Information System (INIS)

    Neale, C.M.U.; Bausch, W.C.; Heermann, D.F.

    1989-01-01

    Concurrent measurements of reflected canopy radiation and the basal crop coefficient (K^b) for corn were conducted throughout a season in order to develop a reflectance-based crop coefficient model. Reflectance was measured in Landsat Thematic Mapper bands TM3 (0.63 - 0.69 um) and TM4 (0.76 - 0.90 um) and used in the calculation of a vegetation index called the normalized difference (ND). A linear transformation of the ND was used as the reflectance-based crop coefficient (Kcr). The transformation equates the ND for dry bare soil and the ND at effective cover, to the basal crop coefficient for dry soil evaporation and at effective cover, respectively. Basal crop coefficient values for com were obtained from daily evapotranspiration measurements of corn and alfalfa, using hydraulic weighing lysimeters. The Richards growth curve function was fitted to both sets of data. The K^b values were determined to be within -2.6% and 4.7% of the K^^ values. The date of effective cover obtained from the K^b data was within four days of the date on which the ND curve reached its maxima according to the Richards function. A comparison of the Kcr with basal crop curves from the literature for several years of data indicated good agreement. Reflectance-based crop coefficients are sensitive to periods of slow and fast growth induced by weather conditions, resulting in a real time coefficient, independent from the traditional time base parameters based on the day of planting and effective cover

  9. Conversion of a gasoline internal combustion engine to operate on hydrogen fuel

    International Nuclear Information System (INIS)

    Bates, M.; Dincer, I.

    2009-01-01

    This study deals with the conversion of a gasoline spark ignition internal combustion engine to operate on hydrogen fuel while producing similar power, economy and reliability as gasoline. The conversion engine will have the fuel system redesigned and ignition and fuel timing changed. Engine construction material is of great importance due to the low ignition energy of hydrogen, making aluminum a desirable material in the intake manifold and combustion chamber. The engine selected to convert is a 3400 SFI dual over head cam General Motors engine. Hydrogen reacts with metals causing hydrogen embrittlement which leads to failure due to cracking. There are standards published by American Society of Mechanical Engineers (ASME) to avoid such a problem. Tuning of the hydrogen engine proved to be challenging due to the basic tuning tools of a gasoline engine such as a wide band oxygen sensor that could not measure the 34:1 fuel air mixture needed for the hydrogen engine. Once the conversion was complete the engine was tested on a chassis dynamometer to compare the hydrogen horsepower and torque produced to that of a gasoline engine. Results showed that the engine is not operating correctly. The engine is not getting the proper amount of fuel needed for complete combustion when operated in a loaded state over 3000 rpm. The problem was found to be the use of the stock injector driver that could not deliver enough power for the proper operation of the larger CM4980 injectors. (author)

  10. Conversion of the 42 keV transition in the decay of 191Os

    International Nuclear Information System (INIS)

    Bhuloka Reddy, S.; Narasimham, K.L.; Thirumala Rao, B.V.; Lakshminarayana, V.

    1986-01-01

    The total as well as the L-conversion coefficient of the 42 KeV transition in the decay of 191 Os are determined from intensity balance considerations and XPG technique, respectively, using a 3 mm Si(Li) detector system. The resultant values are αsub(T) = 13709 (1900), αsub(L) = 11700 (2100). The present total conversion coefficients shows good agreement within the uncertainty limits, with the value αsub(T) = 13.500→ 5200 +21100 reported by Lange, whereas the L-conversion coefficient is reported for the first time. Our present values are also compared with the theoretical values interpolated from the tables of Hager and Seltzer and of Rosel et al

  11. Audio watermarking robust against D/A and A/D conversions

    Directory of Open Access Journals (Sweden)

    Xiang Shijun

    2011-01-01

    Full Text Available Abstract Digital audio watermarking robust against digital-to-analog (D/A and analog-to-digital (A/D conversions is an important issue. In a number of watermark application scenarios, D/A and A/D conversions are involved. In this article, we first investigate the degradation due to DA/AD conversions via sound cards, which can be decomposed into volume change, additional noise, and time-scale modification (TSM. Then, we propose a solution for DA/AD conversions by considering the effect of the volume change, additional noise and TSM. For the volume change, we introduce relation-based watermarking method by modifying groups of the energy relation of three adjacent DWT coefficient sections. For the additional noise, we pick up the lowest-frequency coefficients for watermarking. For the TSM, the synchronization technique (with synchronization codes and an interpolation processing operation is exploited. Simulation tests show the proposed audio watermarking algorithm provides a satisfactory performance to DA/AD conversions and those common audio processing manipulations.

  12. Microwave plasma mode conversion

    International Nuclear Information System (INIS)

    Torres, H.S.; Sakanaka, P.H.; Villarroel, C.H.

    1985-01-01

    The behavior of hot electrons during the process of laser-produced plasma is studied. The basic equations of mode conversion from electromagnetic waves to electrostatic waves are presented. It is shown by mode conversion, that, the resonant absorption and parametric instabilities appear simultaneously, but in different plasma regions. (M.C.K.) [pt

  13. A parameterization scheme for the x-ray linear attenuation coefficient and energy absorption coefficient.

    Science.gov (United States)

    Midgley, S M

    2004-01-21

    A novel parameterization of x-ray interaction cross-sections is developed, and employed to describe the x-ray linear attenuation coefficient and mass energy absorption coefficient for both elements and mixtures. The new parameterization scheme addresses the Z-dependence of elemental cross-sections (per electron) using a simple function of atomic number, Z. This obviates the need for a complicated mathematical formalism. Energy dependent coefficients describe the Z-direction curvature of the cross-sections. The composition dependent quantities are the electron density and statistical moments describing the elemental distribution. We show that it is possible to describe elemental cross-sections for the entire periodic table and at energies above the K-edge (from 6 keV to 125 MeV), with an accuracy of better than 2% using a parameterization containing not more than five coefficients. For the biologically important elements 1 coefficients. At higher energies, the parameterization uses fewer coefficients with only two coefficients needed at megavoltage energies.

  14. Effects of conversion ratio change on the core performances in medium to large TRU burning reactors

    International Nuclear Information System (INIS)

    Song, Hoon; Kim, Sang-Ji; Yoo, Jae-Woon; Kim, Yeong-Il

    2009-01-01

    Conceptual fast reactor core designs with sodium coolant are developed at 1,500, 3,000 and 4,500 MWt which are configured to transmute recycled transuranics (TRU) elements with external feeds consisting of LWR spent fuel. Even at each pre-determined power level, the performance parameters, reactivity coefficients and their implications on the safety analysis can be different when the target TRU conversion ratio changes. In order to address this aspect of design, a study on TRU conversion ratio change was performed. The results indicate that it is feasible to design a TRU burner core to accommodate a wide range of conversion ratios by employing different fuel cladding thicknesses. The TRU consumption rate is found to be proportional to the core power without any significant deterioration in the core performance at higher power levels. A low conversion ratio core has an increased TRU consumption rate and much faster burnup reactivity loss, which calls for appropriate means for reactivity compensation. As for the reactivity coefficients related with the conversion ratio change, the core with a low conversion ratio has a less negative Doppler coefficient, a more negative axial expansion coefficient, a more negative control rod worth per rod, a more negative radial expansion coefficient, a less positive sodium density coefficient and a less positive sodium void worth. A slight decrease in the delayed neutron fraction is also noted, reflecting the fertile U-238 fraction reduction. (author)

  15. Improved spectral absorption coefficient grouping strategy of wide band k-distribution model used for calculation of infrared remote sensing signal of hot exhaust systems

    Science.gov (United States)

    Hu, Haiyang; Wang, Qiang

    2018-07-01

    A new strategy for grouping spectral absorption coefficients, considering the influences of both temperature and species mole ratio inhomogeneities on correlated-k characteristics of the spectra of gas mixtures, has been deduced to match the calculation method of spectral overlap parameter used in multiscale multigroup wide band k-distribution model. By comparison with current spectral absorption coefficient grouping strategies, for which only the influence of temperature inhomogeneity on the correlated-k characteristics of spectra of single species was considered, the improvements in calculation accuracies resulting from the new grouping strategy were evaluated using a series of 0D cases in which radiance under 3-5-μm wave band emitted by hot combustion gas of hydrocarbon fuel was attenuated by atmosphere with quite different temperature and mole ratios of water vapor and carbon monoxide to carbon dioxide. Finally, evaluations are presented on the calculation of remote sensing thermal images of transonic hot jet exhausted from a chevron ejecting nozzle with solid wall cooling system.

  16. Pearson's correlation coefficient in the theory of networks: A comment

    OpenAIRE

    Ahmed, Zafar; Kumar, Sachin

    2018-01-01

    In statistics, the Pearson correlation coefficient $r_{x,y}$ determines the degree of linear correlation between two variables and it is known that $-1 \\le r_{x,y} \\le 1$. In the theory of networks, a curious expression proposed in [PRL {\\bf 89} 208701 (2002)] for degree-degree correlation coefficient $r_{j_i,k_i}, i\\in [1,M]$ has been in use. We realize that the suggested form is the conventional Pearson's coefficient for $\\{(j_i,k_i), (k_i,j_i)\\}$ for $2M$ data points and hence it is rightl...

  17. Transport coefficients of InSb in a strong magnetic field

    International Nuclear Information System (INIS)

    Nakamura, Hiroaki; Ikeda, Kazuaki; Yamaguchi, Satarou

    1998-02-01

    Improvement of a superconducting magnet system makes induction of a strong magnetic field easier. This fact gives us a possibility of energy conversion by the Nernst effect. As the first step to study the Nernst element, we measured the conductivity, the Hall coefficient, the thermoelectric power and the Nernst coefficient of the InSb, which is one of candidates of the Nernst elements. From this experiment, it is concluded that the Nernst coefficient is smaller than the theoretical values. On the other hand, the conductivity, the Hall coefficient and the thermoelectric power has the values expected by the theory. (author)

  18. Experimental Results From a 2kW Brayton Power Conversion Unit

    Science.gov (United States)

    Hervol, David; Mason, Lee; Birchenough, Arthur

    2003-01-01

    This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).

  19. Heat transfer coefficient of cryotop during freezing.

    Science.gov (United States)

    Li, W J; Zhou, X L; Wang, H S; Liu, B L; Dai, J J

    2013-01-01

    Cryotop is an efficient vitrification method for cryopreservation of oocytes. It has been widely used owing to its simple operation and high freezing rate. Recently, the heat transfer performance of cryotop was studied by numerical simulation in several studies. However, the range of heat transfer coefficient in the simulation is uncertain. In this study, the heat transfer coefficient for cryotop during freezing process was analyzed. The cooling rates of 40 percent ethylene glycol (EG) droplet in cryotop during freezing were measured by ultra-fast measurement system and calculated by numerical simulation at different value of heat transfer coefficient. Compared with the results obtained by two methods, the range of the heat transfer coefficient necessary for the numerical simulation of cryotop was determined, which is between 9000 W/(m(2)·K) and 10000 W/(m (2)·K).

  20. A simple theory of linear mode conversion

    International Nuclear Information System (INIS)

    Cairns, R.A.; Lashmore-Davies, C.N.; Woods, A.M.

    1984-01-01

    A summary is given of the basic theory of linear mode conversion involving the construction of differential equations for the mode amplitudes based on the properties of the dispersion relation in the neighbourhood of the mode conversion point. As an example the transmission coefficient for tunneling from the upper hybrid resonance through the evanescent region to the adjacent cut-off is treated. 7 refs, 3 figs

  1. Osmotic and activity coefficients of {y Na2SO4 + (1 - y) ZnSO4}(aq) at T = 298.15 K

    International Nuclear Information System (INIS)

    Marjanovic, V.; Ninkovic, R.; Miladinovic, J.; Todorovic, M.; Pavicevic, V.

    2005-01-01

    The osmotic coefficients of the mixed electrolyte solution {y Na 2 SO 4 + (1 - y) ZnSO 4 }(aq) have been measured by the isopiestic method, at T = 298.5 K. The experimental results were treated by Scatchard's, Pitzer-Kim's and Clegg-Pitzer-Brimblecombe's methods for mixed-electrolyte solutions. By these methods, the activity coefficients for Na 2 SO 4 and ZnSO 4 were calculated and compared. The Scatchard interaction parameters are used for calculation of the excess Gibbs free energy as a function of ionic strength and ionic-strength fraction of Na 2 SO 4 . Also, the Zdanovskii's rule of linearity is tested

  2. High power cable with internal water cooling 400 kV

    Energy Technology Data Exchange (ETDEWEB)

    Rasquin, W; Harjes, B

    1982-08-01

    The project was planned for a duration of 4 years. Afterwards it has been extended over 6 years and finally stopped after 3 1/2 years. Therefore, of course results of field tests with an internally cooled 400 kV cable are not available. Nevertheless, this conductor cooled high power cable has been developed to such an extend, that this manufactured cable could withstand type tests according to IEC/VDE recommendations. Even by missing field tests it is obvious that a high power cable for 400 kV is available.

  3. Confidence bounds and hypothesis tests for normal distribution coefficients of variation

    Science.gov (United States)

    Steve P. Verrill; Richard A. Johnson

    2007-01-01

    For normally distributed populations, we obtain confidence bounds on a ratio of two coefficients of variation, provide a test for the equality of k coefficients of variation, and provide confidence bounds on a coefficient of variation shared by k populations. To develop these confidence bounds and test, we first establish that estimators based on Newton steps from n-...

  4. Converse magnetoelectric effect in laminated composite of Metglas and Pb(Zr,TiO3 with screen-printed interdigitated electrodes

    Directory of Open Access Journals (Sweden)

    Yuan Zhang

    2014-06-01

    Full Text Available In this study, we investigate the converse magnetoelectric (CME effect in a laminated composite consisting of Metglas ribbons and Pb(Zr,TiO3 (PZT plate with screen-printed interdigitated electrodes and operating in longitudinal magnetization and longitudinal polarization (L-L mode. Large CME coefficients of 0.134 G·cm/V at frequency of 1 kHz and 2.75 G·cm/V at resonance frequency of 43.5 kHz under a small bias magnetic field of 7 Oe are achieved. The large CME effect can be attributed to the L-L mode and low mechanical loss of the Metglas/PZT laminated composite.

  5. FIB preparation of a NiO Wedge-Lamella and STEM X-ray microanalysis for the determination of the experimental k(O-Ni) Cliff-Lorimer coefficient.

    Science.gov (United States)

    Armigliato, Aldo; Frabboni, Stefano; Gazzadi, Gian Carlo; Rosa, Rodolfo

    2013-02-01

    A method for the fabrication of a wedge-shaped thin NiO lamella by focused ion beam is reported. The starting sample is an oxidized bulk single crystalline, oriented, Ni commercial standard. The lamella is employed for the determination, by analytical electron microscopy at 200 kV of the experimental k(O-Ni) Cliff-Lorimer (G. Cliff & G.W. Lorimer, J Microsc 103, 203-207, 1975) coefficient, according to the extrapolation method by Van Cappellen (E. Van Cappellen, Microsc Microstruct Microanal 1, 1-22, 1990). The result thus obtained is compared to the theoretical k(O-Ni) values either implemented into the commercial software for X-ray microanalysis quantification of the scanning transmission electron microscopy/energy dispersive spectrometry equipment or calculated by the Monte Carlo method. Significant differences among the three values are found. This confirms that for a reliable quantification of binary alloys containing light elements, the choice of the Cliff-Lorimer coefficients is crucial and experimental values are recommended.

  6. Amide proton temperature coefficients as hydrogen bond indicators in proteins

    International Nuclear Information System (INIS)

    Cierpicki, Tomasz; Otlewski, Jacek

    2001-01-01

    Correlations between amide proton temperature coefficients (Δσ HN /ΔT) and hydrogen bonds were investigated for a data set of 793 amides derived from 14 proteins. For amide protons showing temperature gradients more positive than -4.6 ppb/K there is a hydrogen bond predictivity value exceeding 85%. It increases to over 93% for amides within the range between -4 and -1 ppb/K. Detailed analysis shows an inverse proportionality between amide proton temperature coefficients and hydrogen bond lengths. Furthermore, for hydrogen bonds of similar bond lengths, values of temperature gradients in α-helices are on average 1 ppb/K more negative than in β-sheets. In consequence, a number of amide protons in α-helices involved in hydrogen bonds shorter than 2 A show Δσ HN /ΔT 10 helices and 98% in β-turns have temperature coefficients more positive than -4.6ppb/K. Ring current effect also significantly influences temperature coefficients of amide protons. In seven out of eight cases non-hydrogen bonded amides strongly deshielded by neighboring aromatic rings show temperature coefficients more positive than -2 ppb/K. In general, amide proton temperature gradients do not change with pH unless they correspond to conformational changes. Three examples of pH dependent equilibrium showing hydrogen bond formation at higher pH were found. In conclusion, amide proton temperature coefficients offer an attractive and simple way to confirm existence of hydrogen bonds in NMR determined structures

  7. Measurement of the high-temperature Seebeck coefficient of thin films by means of an epitaxially regrown thermometric reference material.

    Science.gov (United States)

    Ramu, Ashok T; Mages, Phillip; Zhang, Chong; Imamura, Jeffrey T; Bowers, John E

    2012-09-01

    The Seebeck coefficient of a typical thermoelectric material, silicon-doped InGaAs lattice-matched to InP, is measured over a temperature range from 300 K to 550 K. By depositing and patterning a thermometric reference bar of silicon-doped InP adjacent to a bar of the material under test, temperature differences are measured directly. This is in contrast to conventional two-thermocouple techniques that subtract two large temperatures to yield a small temperature difference, a procedure prone to errors. The proposed technique retains the simple instrumentation of two-thermocouple techniques while eliminating the critical dependence of the latter on good thermal contact. The repeatability of the proposed technique is demonstrated to be ±2.6% over three temperature sweeps, while the repeatability of two-thermocouple measurements is about ±5%. The improved repeatability is significant for reliable reporting of the ZT figure of merit, which is proportional to the square of the Seebeck coefficient. The accuracy of the proposed technique depends on the accuracy with which the high-temperature Seebeck coefficient of the reference material may be computed or measured. In this work, the Seebeck coefficient of the reference material, n+ InP, is computed by rigorous solution of the Boltzmann transport equation. The accuracy and repeatability of the proposed technique can be systematically improved by scaling, and the method is easily extensible to other material systems currently being investigated for high thermoelectric energy conversion efficiency.

  8. Improvement of dose evaluation system for employees at severe accident in a nuclear power plant. Introduction of the dose rate conversion coefficient and addition of the access route edit function

    International Nuclear Information System (INIS)

    Sasaki, Yasuhiro; Minami, Noritoshi; Yoshida, Yoshitaka

    2006-01-01

    Institute of Nuclear Safety System, Inc. had developed the dose evaluation system to evaluate the radiation dose of employees at severe accident in a nuclear power plant. This system has features, which are (1) the dose rate of any evaluation point can be evaluated, (2) the dose rate at any time can be evaluated in consideration of the change in the radioactive source, (3) the dose rate map in the plant can be displayed (4) the dose along the access route when moving can be evaluated, and it is possible to use it for examination of the accident management guideline on the dose side etc.. To upgrade the dose evaluation function of this system, the improvements had been done which were introduction of the dose rate conversion coefficient and addition of the access route edit function. By introducing the dose rate conversion coefficient, the calculation time of the dose rate map in the plant was shortened at about 20 seconds, and a new function to evaluate time-dependent dose rate of any evaluation point was added. By adding the access route edit function, it became possible to re-calculate the dose easily at the route change. (author)

  9. Hydrogen photoproduction by photoelectrochemical conversion

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The water-splitting reaction by photoelectrochemical processes has gained much more attention than any of many reactions proposed for solar generation of energy-rich molecules (fuels). The conversion efficiency of the photosystem is the key factor. The higher the efficiency, the more economically feasible will be the conversion scheme. The conversion efficiency is a function of the semiconductor properties, light intensity, spectral quality, properties of the electrolyte, counterelectrode, cell configuration, etc. The semiconductor parameters include band gap, absorption coefficient and diffusion length. The area and material used for a counterelectrode are important when considering polarization losses in a two-electrode system. Besides, the stability problem is also a very important one to meet the requirement for practical applications. This paper reviews some important issues on photoelectrochemical generation of hydrogen by water splitting. It includes energy conversion efficiency, market assessment and cost goal, state of the technology, and future directions for research

  10. Lovkommentar i Karnovs Lovsamling af Lovbekendtgørelse 2014-11-21 nr. 1224 International købelov (CISG: Convention on Contracts for the International Sale of Goods)

    DEFF Research Database (Denmark)

    Lookofsky, Joseph

    2018-01-01

    CISG er en international konvention, som indeholder regler om købsaftaler i international handel. CISG regulerer blandt andet, hvornår en international købsaftale er indgået, købers og sælgers rettigheder, forpligtelser samt misligholdelsesbeføjelser mm. CISG finder anvendelse, dels når såvel...... sælgers som købers hjemland har tiltrådt konventionen, dels når international privatrets regler fører til anvendelsen af en kontraherende stats ret. CISG trådte i kraft 1988-01-01. Den danske ratifikation skete 1989-02-04. CISG er ratificeret af godt 85 andre lande (2017). Som et led i den danske...

  11. Doubling-resolution analog-to-digital conversion based on PIC18F45K80

    Directory of Open Access Journals (Sweden)

    Yueyang Yuan

    2014-08-01

    Full Text Available Aiming at the analog signal being converted into the digital with a higher precision, a method to improve the analog-to-digital converter (ADC resolution is proposed and described. Based on the microcomputer PIC18F45K80 in which the internal ADC modules are embedded, a circuit is designed for doubling the resolution of ADC. According to the circuit diagram, the mathematical formula for calculating this resolution is derived. The corresponding software and print circuit board assembly is also prepared. With the experiment, a 13 bit ADC is achieved based on the 12 bit ADC module predesigned in the PIC18F45K80.

  12. Effect of the reference solution in the measurement of ion activity coefficients using cells with transference at T = 298.15 K

    International Nuclear Information System (INIS)

    Lladosa, Estela; Arce, Alberto; Wilczek-Vera, Grazyna; Vera, Juan H.

    2010-01-01

    This work reports individual activity coefficients of ions at T = 298.15 K in aqueous solutions obtained from voltage values of the respective half-cell ion-selective-electrode and a single-junction Ag-AgCl reference electrode, filled with different reference solutions at different concentrations. For potassium and chloride ions in KCl aqueous solutions, reference solutions of KCl, NaCl, or CsCl were used. For sodium and chloride ions in aqueous NaCl solutions, reference solutions of CsCl were used. Experimental runs were performed at molalities (1, 2, and 3) m of the reference solution. The concentration of the sample solution was increased, starting from around 1 . 10 -3 m, up to the molality of the reference solution. The values of activity coefficients are calculated using the Henderson equation to estimate the liquid-junction potential. Results show that the ionic activity coefficients are independent of the nature and concentration of reference solution.

  13. A conversion method of air-kerma from the primary, scatter and leakage radiations to ambient dose equivalent for calculating the mamography x-ray shielding barrier

    International Nuclear Information System (INIS)

    Kharrati, H.

    2005-01-01

    The primary, scatter, and leakage doses(in Gy), which constitute the data base for calculating shielding requirements for x-ray facilities, are often converted to the equivalent dose (in sievert) by using a constant of conversion of 1.145Sv/Gy. This constant is used for diagnostic radiology as well as for mammography spectra, and is derived by considering an exposure of 1 R corresponds to an air kerma of 8.73 m Gy, which renders by tradition an equivalent dose of 10 mSv. However, this conversion does not take into account the energy dependence of the conversion coefficients relating air kerma to the equivalent dose as described in ICRU report. Moreover, current radiation protection standards propose the use of the quantity ambient dose equivalent in order to qualify the efficiently of given radiation shielding. Therefore, in this study, a new approach has been introduced for derivation ambient dose equivalent from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to ambient dose equivalent for mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium (NMi), National Institute of Standards and Technology (NIST), and International Atomic Energy Agency (AIEA) laboratories. The calculation has been performed by the means of two methods which show a maximum deviation less than 10%2 for the primary, scatter, and leakage radiations. The results show that the conversion coefficients vary from 0.242 Sv/ Gy to 0.692 Sv/Gy with an average value of 0.436 Sv/Gy for the primary and the scatter radiations, and form 0.156 Sv/Gy to 1.329 Sv/Gy with an average value of 0.98 Sv/Gy for the leakage radiation. Simpkin et al. using an empirical approach propose a conversion value of 0.50 Sv/Gy for the mammography x-ray spectra. This value approximately coincides with the average conversion value of 0.436 Sv/Gy obtained in this work for

  14. 26 CFR 1.381(c)(13)-1 - Involuntary conversions.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 4 2010-04-01 2010-04-01 false Involuntary conversions. 1.381(c)(13)-1 Section 1.381(c)(13)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Insolvency Reorganizations § 1.381(c)(13)-1 Involuntary conversions...

  15. Calibration coefficient of the SSNTD and equilibrium factor for radon

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.

    1993-01-01

    Disintegration, ventilation and deposition were considered as removal processes of the radon and its short-lived daughters in air and respective concentration equations were applied. Calibration coefficient (K F ) of the solid state nuclear track detector (SSNTD) LR-115 for radon and the equilibrium factor (F) were related to track densities of the bare detector (D) and the filtered one (D o ). A useful relationship between K F , F and detector sensitivity coefficient (k) was derived. Using the calibrated value k=3.29 * 10 -3 m, the exposed detectors gave the average values of the equilibrium factor, calibration coefficient and indoor radon concentration of a single house living room in Osijek 0.46, 142.3 m -1 and 37.8 Bq m -3 , respectively. (author) 4 refs.; 1 fig

  16. Presentation of the decay data group activities at LPRI. (Links with international evaluation works)

    International Nuclear Information System (INIS)

    Be, M.M.

    1999-01-01

    The activities of the Primary Ionizing Radiation Laboratory (LPRI) which is affiliated with the French National Bureau of Metrology (BNM), include evaluation of decay data, absolute activity measurements, X- and gamma-ray spectrometry, development of new measuring techniques, etc. The following three activities in the field of decay data evaluation are briefly presented: NUCLEIDE software, internal conversion coefficients, and nuclide evaluations

  17. Mass transfer coefficient of slug flow for organic solvent-aqueous system in a microreactor

    Energy Technology Data Exchange (ETDEWEB)

    Tuek, Ana Jurinjak; Anic, Iva; Kurtanjek, Zelimir; Zelic, Bruno [University of Zagreb, Zagreb (Croatia)

    2015-06-15

    Application of microreactor systems could be the next break-through in the intensification of chemical and biochemical processes. The common flow regime for organic solvent-aqueous phase two-phase systems is a segmented flow. Internal circulations in segments cause high mass transfer and conversion. We analyzed slug flow in seven systems of organic solvents and aqueous phase. To analyze how slug lengths in tested systems depend on linear velocity and physical and chemical properties of used organic solvents, regression models were proposed. It was shown that models based on linearization of approximation by potentials give low correlation for slug length prediction; however, application of an essential nonlinear model of multiple layer perception (MLP) neural network gives high correlation with R{sup 2}=0.9. General sensitivity analysis was applied for the MLP neural network model, which showed that 80% of variance in slug length for the both phases is accounted for the viscosity and density of the organic phases; 10% is accounted by surface tension of the organic phase, while molecular masses and flow rates each account for 5%. For defined geometry of microreactor, mass transfer has been determined by carrying out the neutralization experiment with NaOH where acetic acid diffuses from organic phase (hexane) into aqueous phase. Estimated mass transfer coefficients were in the range k{sub L}a=4,652-1,9807 h{sup -1}.

  18. Mass transfer coefficient of slug flow for organic solvent-aqueous system in a microreactor

    International Nuclear Information System (INIS)

    Tuek, Ana Jurinjak; Anic, Iva; Kurtanjek, Zelimir; Zelic, Bruno

    2015-01-01

    Application of microreactor systems could be the next break-through in the intensification of chemical and biochemical processes. The common flow regime for organic solvent-aqueous phase two-phase systems is a segmented flow. Internal circulations in segments cause high mass transfer and conversion. We analyzed slug flow in seven systems of organic solvents and aqueous phase. To analyze how slug lengths in tested systems depend on linear velocity and physical and chemical properties of used organic solvents, regression models were proposed. It was shown that models based on linearization of approximation by potentials give low correlation for slug length prediction; however, application of an essential nonlinear model of multiple layer perception (MLP) neural network gives high correlation with R 2 =0.9. General sensitivity analysis was applied for the MLP neural network model, which showed that 80% of variance in slug length for the both phases is accounted for the viscosity and density of the organic phases; 10% is accounted by surface tension of the organic phase, while molecular masses and flow rates each account for 5%. For defined geometry of microreactor, mass transfer has been determined by carrying out the neutralization experiment with NaOH where acetic acid diffuses from organic phase (hexane) into aqueous phase. Estimated mass transfer coefficients were in the range k L a=4,652-1,9807 h -1

  19. Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy Conversion Devices (a.k.a. Understanding Photosystem I as a Biomolecular Reactor for Energy Conversion)

    Science.gov (United States)

    2014-04-01

    Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy Conversion Devices (a.k.a. Understanding Photosystem I as...Laboratory Adelphi, MD 20783-1197 ARL-TR-6904 April 2014 Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy...Final 3. DATES COVERED (From - To) 10/1/2010–10/1/2013 4. TITLE AND SUBTITLE Hydrogen Production from Water by Photosynthesis System I for Use as Fuel

  20. Use of the Boron partition coefficientKD’ and B/Ca from planktonic foraminifera in the estimation of past seawater pCO2

    Digital Repository Service at National Institute of Oceanography (India)

    Naik, S.S.; Naidu, P.D.

    We assess the usefulness of the empirical boron partition coefficient, KD and B/Ca measured from planktonic foraminifera in estimation of pCO2 using three different relationships between KD and temperature derived...

  1. A study on the determination of diffusion coefficient of carbon in 304 austenitic stainless steels by internal friction method

    International Nuclear Information System (INIS)

    Kim, K.S.; Kim, T.H.

    1982-01-01

    Internal friction peaks associated with the presence of carbon in 18-8 type 304 stainless steel have been observed from measurements with a torsion pendulum. The temperature for maximum internal friction lies between 250degC and 300degC with a frequency of vibration. The height of the peak rises and the position of the peak shifts to a lower temperature with an increase of the carbon content. And a comparison of the activation energy and the diffusion coefficient determined by internal friction methods with those measured in conventional macro-diffusion experiments reveals that the diffusion data measured by internal friction method and the diffusion data measured by conventional method exist in the same line. It follows from the above fact that observed internal friction peak is associated with the stress-induced diffusion of carbon in face-centered cubic alloys. (Author)

  2. Sample environment for neutron scattering measurements of internal stresses in engineering materials in the temperature range of 6 K to 300 K.

    Science.gov (United States)

    Kirichek, O; Timms, J D; Kelleher, J F; Down, R B E; Offer, C D; Kabra, S; Zhang, S Y

    2017-02-01

    Internal stresses in materials have a considerable effect on material properties including strength, fracture toughness, and fatigue resistance. The ENGIN-X beamline is an engineering science facility at ISIS optimized for the measurement of strain and stress using the atomic lattice planes as a strain gauge. Nowadays, the rapidly rising interest in the mechanical properties of engineering materials at low temperatures has been stimulated by the dynamic development of the cryogenic industry and the advanced applications of the superconductor technology. Here we present the design and discuss the test results of a new cryogenic sample environment system for neutron scattering measurements of internal stresses in engineering materials under a load of up to 100 kN and in the temperature range of 6 K to 300 K. Complete cooling of the system starting from the room temperature down to the base temperature takes around 90 min. Understanding of internal stresses in engineering materials at cryogenic temperatures is vital for the modelling and designing of cutting-edge superconducting magnets and other superconductor based applications.

  3. [Energy pooling collisions for K(4P) + Cs(5D) in a K-Cs mixture].

    Science.gov (United States)

    Aihemaiti, Pulati; Dai, Kang; Lu, Xin-hong; Shen, Yi-fan

    2005-04-01

    The rate coefficients for energy-pooling collisions K(4P) + Cs(5D) --> Cs(6S) + K(4D, 6S) in the K-Cs vapor mixture were measured relative to a known energy-pooling rate coefficient of a homonuclear reaction [i. e., Cs(6P) + Cs(5D) --> Cs(6S) + Cs (7D(J))]. Populations of the Cs(6P, 5D) and K(4P) states were produced by photodissociation of K2 and Cs2 molecules through the use of a dye laser radiation. The resulting fluorescence included the direct components emitted in the decay of the excited states produced by photodissociation and the induced components arising from the collisionally populated states. By combining relative intensities of the components with the effective lifetimes of Cs(6P) and K(4P) states, the rate coefficients (in units of 10(-9) cm3 x s(-1)) for the heteronuclear energy-pooling were found to be 2.6 and 3.6, respectively. The contribution to the rate coefficients from other processes are discussed.

  4. Gas-phase rate coefficients for the OH + n-, i-, s-, and t-butanol reactions measured between 220 and 380 K: non-Arrhenius behavior and site-specific reactivity.

    Science.gov (United States)

    McGillen, Max R; Baasandorj, Munkhbayar; Burkholder, James B

    2013-06-06

    Butanol (C4H9OH) is a potential biofuel alternative in fossil fuel gasoline and diesel formulations. The usage of butanol would necessarily lead to direct emissions into the atmosphere; thus, an understanding of its atmospheric processing and environmental impact is desired. Reaction with the OH radical is expected to be the predominant atmospheric removal process for the four aliphatic isomers of butanol. In this work, rate coefficients, k, for the gas-phase reaction of the n-, i-, s-, and t-butanol isomers with the OH radical were measured under pseudo-first-order conditions in OH using pulsed laser photolysis to produce OH radicals and laser induced fluorescence to monitor its temporal profile. Rate coefficients were measured over the temperature range 221-381 K at total pressures between 50 and 200 Torr (He). The reactions exhibited non-Arrhenius behavior over this temperature range and no dependence on total pressure with k(296 K) values of (9.68 ± 0.75), (9.72 ± 0.72), (8.88 ± 0.69), and (1.04 ± 0.08) (in units of 10(-12) cm(3) molecule(-1) s(-1)) for n-, i-, s-, and t-butanol, respectively. The quoted uncertainties are at the 2σ level and include estimated systematic errors. The observed non-Arrhenius behavior is interpreted here to result from a competition between the available H-atom abstraction reactive sites, which have different activation energies and pre-exponential factors. The present results are compared with results from previous kinetic studies, structure-activity relationships (SARs), and theoretical calculations and the discrepancies are discussed. Results from this work were combined with available high temperature (1200-1800 K) rate coefficient data and room temperature reaction end-product yields, where available, to derive a self-consistent site-specific set of reaction rate coefficients of the form AT(n) exp(-E/RT) for use in atmospheric and combustion chemistry modeling.

  5. 26 CFR 1.1001-5 - European Monetary Union (conversion to the euro).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true European Monetary Union (conversion to the euro). 1.1001-5 Section 1.1001-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... § 1.1001-5 European Monetary Union (conversion to the euro). (a) Conversion of currencies. For...

  6. Transfer coefficient of 137Cs and 40K from feed to milk in Kakrapar Gujarat site

    International Nuclear Information System (INIS)

    Wagh, S.S.; Patra, A.K.; John, Jaison T.; Ravi, P.M.; Tripathi, R.M.

    2018-01-01

    117 Cs is one of the most important contaminant from nuclear fall out because of its long physical half-life, affinity for biological systems and its uptake to man through diet. Cesium behaves like Potassium because of its similar physical and chemical properties. One of the important ingestion pathways of 137 Cs is grass to cow, cow to milk and exposed to man due to consumption of milk. Therefore it is necessary to measure the concentration of 137 Cs in grass and milk samples and to calculate the dose to human being due to the consumption of milk. This paper presents 137 Cs and 40 K concentration in feed and milk samples and the respective site-specific transfer coefficients from feed to milk for Kakrapar Gujarat Site

  7. Feasibility study of internal conversion electron spectroscopy of {sup 229m}Th

    Energy Technology Data Exchange (ETDEWEB)

    Seiferle, Benedict; Wense, Lars von der; Thirolf, Peter G. [Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany)

    2017-05-15

    With an expected energy of 7.8(5) eV, the isomeric first excited state in {sup 229}Th exhibits the lowest excitation energy of all known nuclei. Until today, a value for the excitation energy has been inferred only by indirect measurements. In this paper we propose an experimental method that is potentially capable of measuring the ground-state transition energy via the detection of the internal conversion electrons. MatLab-based Monte Carlo simulations have been performed to obtain an estimate of the expected statistics and to test the feasibility and the expected precision of the experiment. From the simulations we conclude that with the presented methods an energy determination with a precision of better than 0.1 eV is within reach. (orig.)

  8. Conversion-electron spectroscopy and gamma-gamma angular correlation measurements in {sup 116}Sn

    Energy Technology Data Exchange (ETDEWEB)

    Cross, D.S.; Pore, J.L.; Andreoiu, C.; Chester, A.S.; Noakes, B.; Starosta, K.; Voss, P. [Simon Fraser University, Department of Chemistry, Burnaby, BC (Canada); Ball, G.C.; Bender, P.C.; Churchman, R.; Garnsworthy, A.B.; Hackman, G.; Miller, D.T. [TRIUMF, Vancouver, BC (Canada); Demand, G.A.; Diaz Varela, A.; Dunlop, R.; Garrett, P.E.; Hadinia, B.; Jigmeddorj, B.; Laffoley, A.T.; Liblong, A.; Svensson, C.E.; Wilson, J.M. [University of Guelph, Department of Physics, Guelph, ON (Canada); Kanungo, R. [Saint Mary' s University, Department of Astronomy and Physics, Halifax, NS (Canada); Petrache, C.M. [CSNSM, CNRS-IN2P3, Universite Paris-Saclay, Orsay (France); Wang, Z.M. [Simon Fraser University, Department of Chemistry, Burnaby, BC (Canada); TRIUMF, Vancouver, BC (Canada); Wood, J.L. [Georgia Institute of Technology, School of Physics, Atlanta, GA (United States); Yates, S.W. [University of Kentucky, Departments of Chemistry and Physics and Astronomy, Lexington, KY (United States)

    2017-11-15

    The {sup 116}Sn nucleus was studied via the β{sup -} decay of {sup 116}In utilizing the 8π spectrometer and its auxiliary detectors at TRIUMF-ISAC. The resulting K-shell conversion coefficients, K/L ratios, and multipole mixing ratios are presented. The 2{sub 3}{sup +} → 2{sub 1}{sup +} 931 keV and 2{sub 2}{sup +} → 2{sub 1}{sup +} 819 keV transition mixing ratios were re-measured and found to be δ = +1.8{sub -0.5}{sup +0.7} and -1.83(8), respectively. Newly measured mixing ratios for transitions among the low-lying I{sup π} = 4{sup +} states in {sup 116}Sn, when combined with γ-ray intensity data, suggest that the 2529 keV 4{sub 2}{sup +} state possesses a neutron broken-pair admixture in addition to its dominant proton 2p-2h component. (orig.)

  9. Computational Chemical Kinetics for the Reaction of Criegee Intermediate CH2OO with HNO3 and Its Catalytic Conversion to OH and HCO.

    Science.gov (United States)

    Raghunath, P; Lee, Yuan-Pern; Lin, M C

    2017-05-25

    The kinetics and mechanisms for the reaction of the Criegee intermediate CH 2 OO with HNO 3 and the unimolecular decomposition of its reaction product CH 2 (O)NO 3 are important in atmospheric chemistry. The potential-energy profile of the reactions predicted with the CCSD(T)/aug-cc-pVTZ//B3LYP/aug-cc-pVTZ method shows that the initial association yields a prereaction complex that isomerizes by H migration to yield excited intermediate nitrooxymethyl hydroperoxide NO 3 CH 2 OOH* with internal energy ∼44 kcal mol -1 . A fragmentation of this excited intermediate produces CH 2 (O)NO 3 + OH with its transition state located 5.0 kcal mol -1 below that of the reactants. Further decomposition of CH 2 (O)NO 3 produces HCO + HNO 3 , forming a catalytic cycle for destruction of CH 2 OO by HNO 3 . The rate coefficients and product-branching ratios were calculated in the temperature range 250-700 K at pressure 20-760 Torr (N 2 ) using the variational-transition-state and Rice-Ramsperger-Kassel-Marcus (RRKM) theories. The predicted total rate coefficient for reaction CH 2 OO + HNO 3 at 295 K, 5.1 × 10 -10 cm 3 molecule -1 s -1 , agrees satisfactorily with the experimental value, (5.4 ± 1.0) × 10 -10 cm 3 molecule -1 s -1 . The predicted branching ratios at 295 K are 0.21 for the formation of NO 3 CH 2 OOH and 0.79 for CH 2 (O)NO 3 + OH at a pressure of 40 Torr (N 2 ), and 0.79 for the formation of NO 3 CH 2 OOH and 0.21 for CH 2 (O)NO 3 + OH at 760 Torr (N 2 ). This new catalytic conversion of CH 2 OO to HCO + OH by HNO 3 might have significant impact on atmospheric chemistry.

  10. A new approach to evaluate factors controlling elemental sediment–seawater distribution coefficients (K{sub d}) in coastal regions, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Hyoe, E-mail: takata@kaiseiken.or.jp [Marine Ecology Research Institute, Central Laboratory, Onjuku, Chiba (Japan); National Institute of Radiological Sciences, Chiba City, Chiba (Japan); Aono, Tatsuo; Tagami, Keiko; Uchida, Shigeo [National Institute of Radiological Sciences, Chiba City, Chiba (Japan)

    2016-02-01

    In numerical models to simulate the dispersion of anthropogenic radionuclides in the marine environment, the sediment–seawater distribution coefficient (K{sub d}) for various elements is an important parameter. In coastal regions, K{sub d} values are largely dependent on hydrographic conditions and physicochemical characteristics of sediment. Here we report K{sub d} values for 36 elements (Na, Mg, Al, K, Ca, V, Mn, Fe, Co, Ni, Cu, Se, Rb, Sr, Y, Mo, Cd, I, Cs, rare earth elements, Pb, {sup 232}Th and {sup 238}U) in seawater and sediment samples from 19 Japanese coastal regions, and we examine the factors controlling the variability of these K{sub d} values by investigating their relationships to hydrographic conditions and sediment characteristics. There was large variability in K{sub d} values for Al, Mn, Fe, Co, Ni, Cu, Se, Cd, I, Pb and Th. Variations of K{sub d} for Al, Mn, Fe, Co, Pb and Th appear to be controlled by hydrographic conditions. Although K{sub d} values for Ni, Cu, Se, Cd and I depend mainly on grain size, organic matter content, and the concentrations of hydrous oxides/oxides of Fe and Mn in sediments, heterogeneity in the surface characteristics of sediment particles appears to hamper evaluation of the relative importance of these factors. Thus, we report a new approach to evaluate the factors contributing to variability in K{sub d} for an element. By this approach, we concluded that the K{sub d} values for Cu, Se, Cd and I are controlled by grain size and organic matter in sediments, and the K{sub d} value for Ni is dependent on grain size and on hydrous oxides/oxides of Fe and Mn. - Highlights: • K{sub d}s for 36 elements were determined in 19 Japanese coastal regions. • K{sub d}s for several elements appeared to be controlled by multiple factors in sediments. • We evaluated these factors based on physico-chemical characteristics of sediments.

  11. Amide temperature coefficients in the protein G B1 domain

    International Nuclear Information System (INIS)

    Tomlinson, Jennifer H.; Williamson, Mike P.

    2012-01-01

    Temperature coefficients have been measured for backbone amide 1 H and 15 N nuclei in the B1 domain of protein G (GB1), using temperatures in the range 283–313 K, and pH values from 2.0 to 9.0. Many nuclei display pH-dependent coefficients, which were fitted to one or two pK a values. 1 H coefficients showed the expected behaviour, in that hydrogen-bonded amides have less negative values, but for those amides involved in strong hydrogen bonds in regular secondary structure there is a negative correlation between strength of hydrogen bond and size of temperature coefficient. The best correlation to temperature coefficient is with secondary shift, indicative of a very approximately uniform thermal expansion. The largest pH-dependent changes in coefficient are for amides in loops adjacent to sidechain hydrogen bonds rather than the amides involved directly in hydrogen bonds, indicating that the biggest determinant of the temperature coefficient is temperature-dependent loss of structure, not hydrogen bonding. Amide 15 N coefficients have no clear relationship with structure.

  12. Background internal dose rates of earthworm and arthropod species in the forests of Aomori, Japan

    International Nuclear Information System (INIS)

    Yoshihito Ohtsuka; Yuichi Takaku; Shun'ichi Hisamatsu

    2015-01-01

    In this study, we measured the concentrations of several natural radionuclides in samples of one earthworm species and 11 arthropod species collected from four coniferous forests in Rokkasho, Aomori Prefecture, Japan, and we assessed the background internal radiation dose rate for each species. Dose rates were calculated by using the radionuclide concentrations in the samples and dose conversion coefficients obtained from the literature. The mean internal dose rate in the earthworm species was 0.28 μGy h -1 , and the mean internal dose rates in the arthropod species ranged between 0.036 and 0.69 μGy h -1 . (author)

  13. Determination and prediction of octanol-air partition coefficients for organophosphate flame retardants.

    Science.gov (United States)

    Wang, Qingzhi; Zhao, Hongxia; Wang, Yan; Xie, Qing; Chen, Jingwen; Quan, Xie

    2017-11-01

    Organophosphate flame retardants (OPFRs) have attracted wide concerns due to their toxicities and ubiquitous occurrence in the environment. In this work, Octanol-air partition coefficient (K OA ) for 14 OPFRs including 4 halogenated alkyl-, 5 aryl- and 5 alkyl-OPFRs, were estimated as a function of temperature using a gas chromatographic retention time (GC-RT) method. Their log K OA-GC values and internal energies of phase transfer (Δ OA U/kJmol -1 ) ranged from 8.03 to 13.0 and from 69.7 to 149, respectively. Substitution pattern and molar volume (V M ) were found to be capable of influencing log K OA-GC values of OPFRs. The halogenated alkyl-OPFRs had higher log K OA-GC values than aryl- or alkyl-OPFRs. The bigger the molar volume was, the greater the log K OA-GC values increased. In addition, a predicted model of log K OA-GC versus different relative retention times (RRTs) was developed with a high cross-validated value (Q 2 (cum) ) of 0.951, indicating a good predictive ability and stability. Therefore, the log K OA-GC values of the remaining OPFRs can be predicted by using their RRTs on different GC columns. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Recursion method in the k-space representation

    International Nuclear Information System (INIS)

    Anlage, S.M.; Smith, D.L.

    1986-01-01

    We show that by using a unitary transformation to k space and the special-k-point method for evaluating Brillouin-zone sums, the recursion method can be very effectively applied to translationally invariant systems. We use this approach to perform recursion calculations for realistic tight-binding Hamiltonians which describe diamond- and zinc-blende-structure semiconductors. Projected densities of states for these Hamiltonians have band gaps and internal van Hove singularities. We calculate coefficients for 63 recursion levels exactly and for about 200 recursion levels to a good approximation. Comparisons are made for materials with different magnitude band gaps (diamond, Si, α-Sn). Comparison is also made between materials with one (e.g., diamond) and two (e.g., GaAs) band gaps. The asymptotic behavior of the recursion coefficients is studied by Fourier analysis. Band gaps in the projected density of states dominate the asymptotic behavior. Perturbation analysis describes the asymptotic behavior rather well. Projected densities of states are calculated using a very simple termination scheme. These densities of states compare favorably with the results of Gilat-Raubenheimer integration

  15. CH3Cl self-broadening coefficients and their temperature dependence

    International Nuclear Information System (INIS)

    Dudaryonok, A.S.; Lavrentieva, N.N.; Buldyreva, J.V.

    2013-01-01

    CH 3 35 Cl self-broadening coefficients at various temperatures of atmospheric interest are computed by a semi-empirical method particularly suitable for molecular systems with strong dipole–dipole interactions. In order to probe the dependence on the rotational number K, the model parameters are adjusted on extensive room-temperature measurements for K≤7 and allow reproducing fine features of J-dependences observed for K≤3; for higher K up to 20, the fitting is performed on specially calculated semi-classical values. The temperature exponents for the standard power law are extracted and validated by calculation of low-temperature self-broadening coefficients comparing very favorably with available experimental data. An extensive line-list of self-broadening coefficients at the reference temperature 296 K and associated temperature exponents for 0≤J≤70, 0≤K≤20 is provided as Supplementary material for their use in atmospheric applications and spectroscopic databases. -- Highlights: • We calculated methyl chloride self-broadening coefficients using two methods. • Rotational quantum numbers were J from 0 till 70 and K from 0 till 20. • The temperature exponents were calculated for every mentioned line

  16. Green technology for conversion of renewable hydrocarbon based on plasma-catalytic approach

    Science.gov (United States)

    Fedirchyk, Igor; Nedybaliuk, Oleg; Chernyak, Valeriy; Demchina, Valentina

    2016-09-01

    The ability to convert renewable biomass into fuels and chemicals is one of the most important steps on our path to green technology and sustainable development. However, the complex composition of biomass poses a major problem for established conversion technologies. The high temperature of thermochemical biomass conversion often leads to the appearance of undesirable byproducts and waste. The catalytic conversion has reduced yield and feedstock range. Plasma-catalytic reforming technology opens a new path for biomass conversion by replacing feedstock-specific catalysts with free radicals generated in the plasma. We studied the plasma-catalytic conversion of several renewable hydrocarbons using the air plasma created by rotating gliding discharge. We found that plasma-catalytic hydrocarbon conversion can be conducted at significantly lower temperatures (500 K) than during the thermochemical ( 1000 K) and catalytic (800 K) conversion. By using gas chromatography, we determined conversion products and found that conversion efficiency of plasma-catalytic conversion reaches over 85%. We used obtained data to determine the energy yield of hydrogen in case of plasma-catalytic reforming of ethanol and compared it with other plasma-based hydrogen-generating systems.

  17. Modification of van La ar activity coefficient model

    International Nuclear Information System (INIS)

    Vakili-Nezhaad, G. R.; Modarress, H.; Mansoori, G. A.

    2001-01-01

    Based on statistical and mechanical arguments, the original van La ar activity coefficient model has been improved by reasonable assumptions. This modifications has been done by replacing the van der Waals equation of state with the Redlich-K wong equation of state in the formulation of van La ar with consistent mixing rules for the energy and volume parameters of this equation of state (a mix , b mix ). Other equations of state, such as the Soave modification of the Redlich-K wong equation of state, P eng-Robinson and Mohsen-Nia, Modarress and Mansoori equations of state, have been introduced in the formulation of van La ar for the activity coefficients of the components present in the binary liquid mixtures, and their effects on the accuracy of the resultant activity coefficient models have been examined. The results of these revised models have been compared with the experimental data and it was found that the Redlich-K wong equation of state with the van der Waals mixing rules for the volume and energy parameters of this equation, is the best choice among these equations of state. In addition, it can improve the original van La ar activity coefficient model and, therefore a better agreement with the experimental data is obtained

  18. Re-patterning of H3K27me3, H3K4me3 and DNA methylation during fibroblast conversion into induced cardiomyocytes

    Directory of Open Access Journals (Sweden)

    Ziqing Liu

    2016-03-01

    Full Text Available Direct conversion of fibroblasts into induced cardiomyocytes (iCMs offers an alternative strategy for cardiac disease modeling and regeneration. During iCM reprogramming, the starting fibroblasts must overcome existing epigenetic barriers to acquire the CM-like chromatin pattern. However, epigenetic dynamics along this reprogramming process have not been studied. Here, we took advantage of our recently generated polycistronic system and determined the dynamics of two critical histone marks, H3K27me3 and H3K4me3, in parallel with gene expression at a set of carefully selected cardiac and fibroblast loci during iCM reprogramming. We observed reduced H3K27me3 and increased H3K4me3 at cardiac promoters as early as day 3, paralleled by a rapid significant increase in their mRNA expression. In contrast, H3K27me3 at loci encoding fibroblast marker genes did not increase until day 10 and H3K4me3 progressively decreased along the reprogramming process; these changes were accompanied by a gradual decrease in the mRNA expression of fibroblast marker genes. Further analyses of fibroblast-enriched transcription factors revealed a similarly late deposition of H3K27me3 and decreased mRNA expression of Sox9, Twist1 and Twist2, three important players in epithelial−mesenchymal transition. Our data suggest early rapid activation of the cardiac program and later progressive suppression of fibroblast fate at both epigenetic and transcriptional levels. Additionally, we determined the DNA methylation states of representative cardiac promoters and found that not every single CpG was equally demethylated during early stages of iCM reprogramming. Rather, there are specific CpGs, whose demethylation states correlated tightly with transcription activation, that we propose are the major contributing CpGs. Our work thus reveals a differential re-patterning of H3K27me3, H3K4me3 at cardiac and fibroblast loci during iCM reprogramming and could provide future genome

  19. Progress and cooperation. Y2K, safeguards and physical protection

    International Nuclear Information System (INIS)

    Chitumbo, K.; Hilliard, J.; Smith, J.

    1999-01-01

    The Year 2000 problem poses major technical challenges to computer systems. For that reason it has drawn considerable attention over the past four years at the IAEA and within the international safeguards community of States and organisations. Actions of IAEA are very close to completion for the conversion of al related systems to make them Y2K compliant. As a result of IAEA past work and continuing liaison with Member States, the following needs were identified: organizing assistance and/or training to help states evaluate existing accounting software, and upgrade it or develop new Y2K compliant software; providing Y2K compliant software when needed; providing guidance and assistance on physical protection issues; organizing assistance missions visiting a state encountering problems; establishing contingency plans

  20. K-scrambling in a near-symmetric top molecule containing an excited noncoaxial internal rotor

    International Nuclear Information System (INIS)

    Ortigoso, Juan; Hougen, Jon T.

    2000-01-01

    Classical trajectories on rotational energy surfaces and coherent-state quantum projections have been used to study an asymmetric-top molecule containing a freely rotating internal symmetric top whose symmetry axis is not coincident with a principal axis of the molecule. Stationary points on the rotational energy surface, which strongly influence the trajectories, increase in number from two to four to six as J/n increases from zero to infinity (where J is the total and n is the free-internal-rotor angular momentum). For some J/n values trajectories can arise that sample a large fraction of K values (where K is the z-axis projection of J), corresponding in quantum wave functions to extensive K mixing in the symmetric-top basis set |J,K>. When such mixing cannot be made small for any choice of z axis, we call it K scrambling. For typical values of the torsion-rotation coupling parameter ρ, rotational eigenfunctions for a given J and torsional state turn out to be quite different from eigenfunctions for the same J in some other torsional state. Nonzero rotational overlap integrals are then distributed among many rotational functions for each (n,n ' ) pair, which may, in turn, contribute to internal rotation enhancement of intramolecular vibrational energy redistribution. We have also examined near-free-rotor levels of our test molecule acetaldehyde, which arise for excitation of ten or more quanta of methyl group torsion, and find that barrier effects do not change the qualitative picture obtained from the free-rotor treatment. (c) 2000 American Institute of Physics

  1. Research on energy conversion mechanism of a screw centrifugal pump under the water

    International Nuclear Information System (INIS)

    Quan, H; Li, R N; Han, W; Cheng, X R; Shen, Z J; Su, Q M

    2013-01-01

    In order to research screw centrifugal pump impeller power capability and energy conversion mechanism, we used Navier-Stokes equation and standard k-ε equation turbulence model on the basis of the Euler equations to carry out screw centrifugal pump internal flow numerical simulation. This was explored by simulating specific design conditions; the medium is water, variation of speed and pressure of flow filed under the action of the impeller, and the screw centrifugal impeller shroud line and wheel line segment take monitoring sites. The monitoring points are between dynamic head and static head change to analyze the energy conversion capability along the impeller corners of screw centrifugal pump. The results show that the energy of fluid of the screw centrifugal pump is provided by spiral segment, the spiral segment in front of the impeller has played a multi-level role, it has significant reference value to research the energy conversion mechanism of screw centrifugal pump under solid-liquid two phase

  2. Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110

    International Nuclear Information System (INIS)

    Galeano, D.C.; Santos, W.S.; Alves, M.C.; Souza, D.N.; Carvalho, A.B.

    2016-01-01

    The aim of this work was to modify the standing posture of the anthropomorphic reference phantoms of ICRP publication 110, AM (Adult Male) and AF (Adult Female), to the sitting posture. The change of posture was performed using the Visual Monte Carlo software (VMC) to rotate the thigh region of the phantoms and position it between the region of the leg and trunk. Scion Image software was used to reconstruct and smooth the knee and hip contours of the phantoms in a sitting posture. For 3D visualization of phantoms, the VolView software was used. In the change of postures, the organ and tissue masses were preserved. The MCNPX was used to calculate the equivalent and effective dose conversion coefficients (CCs) per fluence for photons for six irradiation geometries suggested by ICRP publication 110 (AP, PA, RLAT, LLAT, ROT and ISO) and energy range 0.010–10 MeV. The results were compared between the standing and sitting postures, for both sexes, in order to evaluate the differences of scattering and absorption of radiation for different postures. Significant differences in the CCs for equivalent dose were observed in the gonads, colon, prostate, urinary bladder and uterus, which are present in the pelvic region, and in organs distributed throughout the body, such as the lymphatic nodes, muscle, skeleton and skin, for the phantoms of both sexes. CCs for effective dose showed significant differences of up to 16% in the AP irradiation geometry, 27% in the PA irradiation geometry and 13% in the ROT irradiation geometry. These results demonstrate the importance of using phantoms in different postures in order to obtain more precise conversion coefficients for a given exposure scenario. - Highlights: • The reference phantoms AM and AF had modified its posture. • The AM and AF phantoms were irradiated in standing and sitting postures. • The irradiation geometry used were the AP, PA, LLAT, RLAT, ROT and ISO. • The CCs for standing and sitting postures were compared

  3. Fluxes of Ca2+ and K+ are required for the listeriolysin O-dependent internalization pathway of Listeria monocytogenes.

    Science.gov (United States)

    Vadia, Stephen; Seveau, Stephanie

    2014-03-01

    Listeria monocytogenes is responsible for the life-threatening food-borne disease listeriosis. This disease mainly affects elderly and immunocompromised individuals, causing bacteremia and meningoencephalitis. In pregnant women, L. monocytogenes infection leads to abortion and severe infection of the fetus or newborn. The L. monocytogenes intracellular life cycle is critical for pathogenesis. Previous studies have established that the major virulence factor of L. monocytogenes, the pore-forming toxin listeriolysin O (LLO), is sufficient to induce L. monocytogenes internalization into human epithelial cell lines. This internalization pathway strictly requires the formation of LLO pores in the plasma membrane and can be stimulated by the heterologous pore-forming toxin pneumolysin, suggesting that LLO acts nonspecifically by forming transmembrane pores. The present work tested the hypothesis that Ca2+ and K+ fluxes subsequent to perforation by LLO control L. monocytogenes internalization. We report that L. monocytogenes perforates the host cell plasma membrane in an LLO-dependent fashion at the early stage of invasion. In response to perforation, host cells undergo Ca2+ -dependent but K+ -independent resealing of their plasma membrane. In contrast to the plasma membrane resealing process, LLO-induced L. monocytogenes internalization requires both Ca2+ and K+ fluxes. Further linking ion fluxes to bacterial internalization, treating cells with a combination of Ca2+ and K+ ionophores but not with individual ionophores is sufficient to induce efficient internalization of large cargoes, such as 1-μm polystyrene beads and bacteria. We propose that LLO-induced L. monocytogenes internalization requires a Ca2+ - and K+ -dependent internalization pathway that is mechanistically distinct from the process of plasma membrane resealing.

  4. Osmotic and activity coefficients in the binary solutions of 1-butyl-3-methylimidazolium chloride and bromide in methanol or ethanol at T = 298.15 K from isopiestic measurements

    International Nuclear Information System (INIS)

    Sardroodi, Jaber Jahanbin; Azamat, Jafar; Atabay, Maryam

    2011-01-01

    Highlights: → The osmotic coefficients of the solutions of 1-butyl-3-methylimidazolium chloride and bromide in ethanol and methanol have been measured. → Measured osmotic coefficients were correlated using NRTL and Pitzer models. → Vapor pressures were evaluated from the correlated osmotic coefficients. → Model parameters have been interpreted in terms of ion-ion and ion-solvent interactions. - Abstract: Osmotic coefficients of the binary solutions of two room-temperature ionic liquids (1-butyl-3-methylimidazolium chloride and bromide) in methanol and ethanol have been measured at T = 298.15 K by the isopiestic method. The experimental osmotic coefficient data have been correlated using a forth-order polynomial in terms of (molality) 0.5 , with both, ion interaction model of Pitzer and electrolyte non-random two liquid (e-NRTL) model of Chen. The values of vapor pressures of above-mentioned solutions have been calculated from the osmotic coefficients. The model parameters fitted to the experimental osmotic coefficients have been used for prediction of the mean ionic activity coefficients of those ionic liquids in methanol and ethanol.

  5. Conversion of electromagnetic waves at the ionisation front

    International Nuclear Information System (INIS)

    Chegotov, M V

    2001-01-01

    It is shown that a weak electromagnetic pulse interacting with a copropagating ionisation front is converted in the general case into three electromagnetic pulses with higher and lower frequencies, which propagate in different directions. The coefficients of conversion to these pulses (for intensities) were found as functions of the frequency. The electromagnetic energy is shown to decrease during this conversion because of the losses for the residual electron energy. (interaction of laser radiation with matter. laser plasma)

  6. Conversion electron spectroscopy in transfermium nuclei

    International Nuclear Information System (INIS)

    Herzberg, R.D.

    2003-01-01

    Conversion electron spectroscopy is an essential tool for the spectroscopy of heavy deformed nuclei. The conversion electron spectrometer SACRED has been used in conjunction with the gas-filled recoil separator RITU to study conversion electron cascades in 254 No. The spectra reveal the ground state rotational bands down to low spin. A detailed analysis of the background seen for 254 No shows that approximately 40% of the decay path goes via excited high K bands which may be built on an isomer. (orig.)

  7. The Seebeck coefficient of monocrystalline α-SiC and polycrystalline β-SiC measured at 300-533 K

    Science.gov (United States)

    Abu-Ageel, N.; Aslam, M.; Ager, R.; Rimai, L.

    2000-01-01

    The temperature dependence of the Seebeck coefficient of polycrystalline icons/Journals/Common/beta" ALT="beta" ALIGN="TOP"/> -SiC films deposited on quartz substrates by laser ablation and of commercially available icons/Journals/Common/alpha" ALT="alpha" ALIGN="TOP"/> -SiC wafers is reported in a temperature range of 300-533 K for the first time. The Seebeck emf of icons/Journals/Common/alpha" ALT="alpha" ALIGN="TOP"/> -SiC substrates and icons/Journals/Common/beta" ALT="beta" ALIGN="TOP"/> -SiC samples ranges between -9 µV °C-1 and -108 µV °C-1 which is higher than that of commercial Pt thermocouples.

  8. On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems

    Directory of Open Access Journals (Sweden)

    Nick Reynaert

    2018-01-01

    Full Text Available Background and purpose: Conversion factors between dose to medium (Dm,m and dose to water (Dw,w provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11 largely overestimates the conversion obtained using the Monte Carlo calculations (1.06. In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparison

  9. Vapour pressures and osmotic coefficients of binary mixtures of 1-ethyl-3-methylimidazolium ethylsulfate and 1-ethyl-3-methylpyridinium ethylsulfate with alcohols at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gonzalez, Begona; Dominguez, Angeles; Macedo, Eugenia A.

    2009-01-01

    Osmotic coefficients of binary mixtures containing alcohols (ethanol, 1-propanol, and 2-propanol) and the ionic liquids 1-ethyl-3-methylimidazolium ethylsulfate and 1-ethyl-3-methylpyridinium ethylsulfate were determined at T = 323.15 K. Vapour pressure and activity coefficients of the studied systems were calculated from experimental data. The extended Pitzer model modified by Archer, and the modified NRTL model (MNRTL) were used to correlate the experimental data, obtaining standard deviations lower than 0.012 and 0.031, respectively. The mean molal activity coefficients and the excess Gibbs free energy of the studied binary mixtures were calculated from the parameters obtained with the extended Pitzer model of Archer.

  10. Roughness coefficient and its uncertainty in gravel-bed river

    Directory of Open Access Journals (Sweden)

    Ji-Sung Kim

    2010-06-01

    Full Text Available Manning's roughness coefficient was estimated for a gravel-bed river reach using field measurements of water level and discharge, and the applicability of various methods used for estimation of the roughness coefficient was evaluated. Results show that the roughness coefficient tends to decrease with increasing discharge and water depth, and over a certain range it appears to remain constant. Comparison of roughness coefficients calculated by field measurement data with those estimated by other methods shows that, although the field-measured values provide approximate roughness coefficients for relatively large discharge, there seems to be rather high uncertainty due to the difference in resultant values. For this reason, uncertainty related to the roughness coefficient was analyzed in terms of change in computed variables. On average, a 20% increase of the roughness coefficient causes a 7% increase in the water depth and an 8% decrease in velocity, but there may be about a 15% increase in the water depth and an equivalent decrease in velocity for certain cross-sections in the study reach. Finally, the validity of estimated roughness coefficient based on field measurements was examined. A 10% error in discharge measurement may lead to more than 10% uncertainty in roughness coefficient estimation, but corresponding uncertainty in computed water depth and velocity is reduced to approximately 5%. Conversely, the necessity for roughness coefficient estimation by field measurement is confirmed.

  11. Sediment pore water distribution coefficients of PCB congeners in enriched black carbon sediment

    International Nuclear Information System (INIS)

    Martinez, Andres; O'Sullivan, Colin; Reible, Danny; Hornbuckle, Keri C.

    2013-01-01

    More than 2300 sediment pore water distribution coefficients (K PCBids ) of 93 polychlorinated biphenyls (PCBs) were measured and modeled from sediments from Indiana Harbor and Ship Canal. K PCBids were calculated from previously reported bulk sediment values and newly analyzed pore water. PCBs in pore waters were measured using SPME PDMS-fiber and ∑PCB ranged from 41 to 1500 ng L −1 . The resulting K PCBids were ∼1 log unit lower in comparison to other reported values. A simple model for the K PCBid consisted of the product of the organic carbon fraction and the octanol–water partition coefficient and provided an excellent prediction for the measured values, with a mean square error of 0.09 ± 0.06. Although black carbon content is very high in these sediments and was expected to play an important role in the distribution of PCBs, no improvement was obtained when a two-carbon model was used. -- Highlights: •PCB sediment-pore water distribution coefficients were measured and modeled. •Distribution coefficients were lower in comparison to other reported values. •Organic carbon fraction times the K OW yielded the best prediction model. •The incorporation of black carbon into a model did not improve the results. -- The organic carbon fraction times the octanol–water partition coefficient yielded the best prediction model for the sediment pore water distribution coefficient of PCBs

  12. Kinetic coefficients for the biological treatment of tannery wastewater

    International Nuclear Information System (INIS)

    Haydar, S.

    2008-01-01

    Determination of kinetic coefficients for a particular wastewater is imperative for the rational design of biological treatment-facilities. The present study was undertaken with the objective of finding out kinetic coefficients for tannery wastewater. A bench-scale model of aerated lagoon, consisting of an aeration tank and final clarifier, was use to conduct the studies. The model was operated continuously for 96 days, by varying the detention times from 3 to 9 days. Influent for the aerated lagoon was settled tannery wastewater. Biochemical oxygen demand (BOD) of the influent and effluent and the mixed-liquor suspended solids (MLSS) of aeration tank were determined at various detention-times so as to generate data for kinetic coefficients. The kinetic coefficients k, Ks, Y and Ed were found to be 3.125 day/sup -1/, 488 mg/L, 0.64 and 0.035 day/sup -1/ respectively. Overall rate-constant of BOD, removal 'K' was also determined and was found to be 1.43 day/sup -1/. Kinetic coefficients were determined, at mean reactor-temperature of 30.2 degree C. These coefficients may be utilized for the design of biological-treatment facilities for tannery wastewater. (author)

  13. Longitudinal dispersion coefficient depending on superficial velocity of hydrogen isotopes flowing in column packed with zeolite pellets at 77.4 K

    Energy Technology Data Exchange (ETDEWEB)

    Kotoh, K. [Faculty of Engineering, Kyushu University, Nishi-ku, Fukuoka (Japan); Graduate School of Engineering, Kyushu University, Nishi-ku, Fukuoka (Japan); Kubo, K.; Takashima, S.; Moriyama, S.T. [Graduate School of Engineering, Kyushu University, Nishi-ku, Fukuoka (Japan); Tanaka, M. [National Institute for Fusion Science, Oroshi-cho, Toki, Gifu (Japan); Sugiyama, T. [Faculty of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya (Japan)

    2015-03-15

    Authors have been developing a cryogenic pressure swing adsorption system for hydrogen isotope separation. In the problem of its design and operation, it is necessary to predict the concentration profiles developing in packed beds of adsorbent pellets. The profiling is affected by the longitudinal dispersion of gas flowing in packed beds, in addition to the mass transfer resistance in porous media of adsorbent pellets. In this work, an equation is derived for estimating the packed-bed dispersion coefficient of hydrogen isotopes, by analyzing the breakthrough curves of trace D{sub 2} or HD replacing H{sub 2} adsorbed in synthetic zeolite particles packed columns at the liquefied nitrogen temperature 77.4 K. Since specialized for hydrogen isotopes, this equation can be considered to estimate the dispersion coefficients more reliable for the cryogenic hydrogen isotope adsorption process, than the existing equations. (authors)

  14. Temperature dependence of Kerr coefficient and quadratic polarized optical coefficient of a paraelectric Mn:Fe:KTN crystal

    Directory of Open Access Journals (Sweden)

    Qieni Lu

    2015-08-01

    Full Text Available We measure temperature dependence on Kerr coefficient and quadratic polarized optical coefficient of a paraelectric Mn:Fe:KTN crystal simultaneously in this work, based on digital holographic interferometry (DHI. And the spatial distribution of the field-induced refractive index change can also be visualized and estimated by numerically retrieving sequential phase maps of Mn:Fe:KTN crystal from recording digital holograms in different states. The refractive indices decrease with increasing temperature and quadratic polarized optical coefficient is insensitive to temperature. The experimental results suggest that the DHI method presented here is highly applicable in both visualizing the temporal and spatial behavior of the internal electric field and accurately measuring electro-optic coefficient for electrooptical media.

  15. A reliability generalization meta-analysis of coefficient alpha and test-retest coefficient for the aging males' symptoms (AMS) scale.

    Science.gov (United States)

    Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen

    2016-12-01

    The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.

  16. Determination and prediction of octanol-air partition coefficients of hydroxylated and methoxylated polybrominated diphenyl ethers.

    Science.gov (United States)

    Zhao, Hongxia; Xie, Qing; Tan, Feng; Chen, Jingwen; Quan, Xie; Qu, Baocheng; Zhang, Xin; Li, Xiaona

    2010-07-01

    The octanol-air partition coefficient (K(OA)) of 19 hydroxylated polybrominated diphenyl ethers (OH-PBDEs) and 10 methoxylated polybrominated diphenyl ethers (MeO-PBDEs) were measured as a function of temperature using a gas chromatographic retention time technique. At room temperature (298.15K), log K(OA) ranged from 8.30 for monobrominated OH/MeO-PBDEs to 13.29 for hexabrominated OH/MeO-PBDEs. The internal energies of phase change from octanol to air (Delta(OA)U) for 29 OH/MeO-PBDE congeners ranged from 72 to 126 kJ mol(-1). Using partial least-squares (PLS) analysis, a statistically quantitative structure-property relationship (QSPR) model for logK(OA) of OH/MeO-PBDE congeners was developed based on the 16 fundamental quantum chemical descriptors computed by PM3 Hamiltonian, for which the Q(cum)(2) was about 0.937. The molecular weight (Mw) and energy of the lowest unoccupied molecular orbital (E(LUMO)) were found to be main factors governing the log K(OA). 2010 Elsevier Ltd. All rights reserved.

  17. The anisotropic creep behaviour of zircaloy-4 fuel cladding at 1073 K

    International Nuclear Information System (INIS)

    Rosinger, H.E.; Bowden, J.; Shewfelt, R.S.W.

    1982-04-01

    The anisotropy coefficients (F, G and H) of Hill's equation, suitably modified for creep deformation, have been determined for Zircaloy-4 fuel cladding from steady-state creep tests at an elevated temperature. Creep specimens were subjected to both uniaxial and biaxial loads (via internal pressure) at 1073 K and the strain measured concurrently in the axial and tangential directions. It has been found that Zircaloy-4 fuel cladding is almost, but not completely, isotropic at 1073 K; the values of F, G and H are 0.57, 0.48 and 0.45 respectively

  18. Dalitz Plot Analysis of the Decay B+ -> K+K+K-

    Energy Technology Data Exchange (ETDEWEB)

    Dvoretskii, Alexei; /SLAC /Caltech

    2006-05-05

    The authors perform an analysis of the three-body charmless decay B{sup {+-}} {yields} K{sup {+-}}K{sup {+-}}K{sup {-+}} using a sample of 226.0 {+-} 2.5 million B{bar B} pairs collected by the BABAR detector and measure the total branching fraction and Cp asymmetry to be {beta} = (35.2 {+-} 0.9 {+-} 1.6) x 10{sup -6} and A{sub CP} = (-1.7 {+-} 2.6 {+-} 1.5)%. They fit the Dalitz plot distribution using an isobar model and report the measured values of magnitudes and phases of the production coefficients. The decay dynamics is dominated by the K{sup +}K{sup -} S-wave, for which we perform a partial-wave analysis in the region m(K{sup +}K{sup -}) < 2 GeV/c{sup 2}. They find no evidence of CP violation for individual components of the isobar model.

  19. Near K-edge measurement of the X-ray attenuation coefficient of heavy elements using a tuneable X-ray source based on an electron LINAC

    CERN Document Server

    Materna, T; Mondelaers, W; Masschaele, B

    2000-01-01

    The X-ray attenuation coefficients of bismuth and of uranium were measured in the regions of 40-240 and 70-240 keV, respectively, using a tuneable hard X-ray source based on the linear electron accelerator at the University of Ghent. Results were compared with the semi-empirical values of Storm and Israel and to the theoretical values of Berger and Hubbell. We also propose a simple function for the attenuation coefficient in the vicinity of the K-edge for uranium and in an extended range of energy for bismuth. The set-up of the source at Ghent is described and the future improvements are explained.

  20. The Peltier and Zeebeck coefficients of the Cd-CdI2 melt

    International Nuclear Information System (INIS)

    Kuzyakin, E.B.; Kuz'minskij, E.V.

    1979-01-01

    For the CdI 2 -Cd melt with the usage of molybdenum ''inert'' electrodes in the temperature range of 670-850 K and metal cadmium concentration of 0-5 mol % experimentally determined are the Peltier (PI = 0.67+0.07 V at T = 722 K and 0.23 mol %) and Zeebeck (epsilonsub(in) 1.175+-0.107 mV/deg -1 at 0.20 mol % Cd and T = 700-780 K) coefficients. Calculated is heat transfer coefficient from the electrode to the melt (a = 65+-10 W/m 2 K), reaffirmed is applicability of the second Thomson ratio (PI = Txepsilonsub(in)). It is shown that the method of non-stationary temperature waves, suggested for the Peltier coefficient determination can be applied for evaluation of metal solubility values in their molten salts

  1. The static pressure and temperature coefficients of laboratory standard microphones

    DEFF Research Database (Denmark)

    Rasmussen, Knud

    1999-01-01

    , for a given type of microphone, can be described by a single function when the coefficients are normalized by their low-frequency value and the frequency is normalized with respect to the individual resonance frequency of the microphone. The theoretical results are supported by experimentally determined...... on an extended lumped parameter representation of the mechanical and acoustic elements of the microphone. The extension involves the frequency dependency of the dynamic diaphragm mass and stiffness as well as a first-order approximation of resonances in the back cavity. It was found that each coefficient...... coefficients for about twenty samples of microphone types B&K 4160 and B&K 4180....

  2. Internal friction and shear modulus in Al-Ga alloys (80-320 K)

    International Nuclear Information System (INIS)

    Chountas, K.; Andronikos, P.; Papathanassopoulos, K.

    1977-01-01

    The internal friction and shear modulus of polycrystalline Al + (0.2, 0.7, 2 and 4) at.% Ga was measured as a function of temperature, using measurements of logarithmic decrement and frequency of free sample vibration. The internal friction curves for the smaller solute concentrations went through a maximum (peak) at 230 K. The height of the peak increased initially with solute concentration, then disappeared at higher concentrations. This peak is probably due to the interaction of solute atoms with dislocations. The continuous increase in internal friction at higher temperatures, reported in pure Al, was not found in these alloys. This absence is probably due to the pinning of dislocations by Ga atoms. (author)

  3. K' εK) in the chiral limit

    International Nuclear Information System (INIS)

    Bijnens, J.; Prades, J.

    2000-01-01

    The K→ππ system is analyzed in the chiral limit within the Standard Model. We discuss how to connect the short-distance running in the |Δ S| = 1 case to the matrix-elements calculated in a low-energy approximation in a scheme-independent fashion. We calculate this correction and the resulting Wilson Coefficients. The matrix elements are calculated to next-to-leading order in the 1/N c expansion and combined with the Wilson coefficients to calculate the two isospin amplitudes and ε K '. The Δ I =1/2 rule is reproduced within expected errors and we obtain a substantially larger value for ε K ' ε K than most other analyses. We discuss the reasons for this difference. We also suggest that the X-boson method is an option for lattice QCD calculations. (author)

  4. Digital computer study of nuclear reactor thermal transients during startup of 60-kWe Brayton power conversion system

    Science.gov (United States)

    Jefferies, K. S.; Tew, R. C.

    1974-01-01

    A digital computer study was made of reactor thermal transients during startup of the Brayton power conversion loop of a 60-kWe reactor Brayton power system. A startup procedure requiring the least Brayton system complication was tried first; this procedure caused violations of design limits on key reactor variables. Several modifications of this procedure were then found which caused no design limit violations. These modifications involved: (1) using a slower rate of increase in gas flow; (2) increasing the initial reactor power level to make the reactor respond faster; and (3) appropriate reactor control drum manipulation during the startup transient.

  5. Radionuclides distribution coefficient of soil to soil-solution

    International Nuclear Information System (INIS)

    1990-06-01

    The present book addresses various issues related with the coefficient of radionuclides distribution between soil and soil solution. It consists of six sections and two appendices. The second section, following an introductory one, describes the definition of the coefficient and a procedures of its calculation. The third section deals with the application of the distribution coefficient to the prediction of movements of radionuclides through soil. Various methods for measuring the coefficient are described in the fourth section. The next section discusses a variety of factors (physical and chemical) that can affect the distribution coefficient. Measurements of the coefficient for different types of oils are listed in the sixth section. An appendix is attached to the book to show various models that can be helpful in applying the coefficient of distribution of radionuclides moving from soil into agricultural plants. (N.K.)

  6. Fluence-to-absorbed-dose conversion coefficients for neutron beams from 0.001 eV to 100 GeV calculated for a set of pregnant female and fetus models

    International Nuclear Information System (INIS)

    Taranenko, Valery; Xu, X George

    2008-01-01

    Protection of fetuses against external neutron exposure is an important task. This paper reports a set of absorbed dose conversion coefficients for fetal and maternal organs for external neutron beams using the RPI-P pregnant female models and the MCNPX code. The newly developed pregnant female models represent an adult female with a fetus including its brain and skeleton at the end of each trimester. The organ masses were adjusted to match the reference values within 1%. For the 3 mm cubic voxel size, the models consist of 10-15 million voxels for 35 organs. External monoenergetic neutron beams of six standard configurations (AP, PA, LLAT, RLAT, ROT and ISO) and source energies 0.001 eV-100 GeV were considered. The results are compared with previous data that are based on simplified anatomical models. The differences in dose depend on source geometry, energy and gestation periods: from 20% up to 140% for the whole fetus, and up to 100% for the fetal brain. Anatomical differences are primarily responsible for the discrepancies in the organ doses. For the first time, the dependence of mother organ doses upon anatomical changes during pregnancy was studied. A maximum of 220% increase in dose was observed for the placenta in the nine months model compared to three months, whereas dose to the pancreas, small and large intestines decreases by 60% for the AP source for the same models. Tabulated dose conversion coefficients for the fetus and 27 maternal organs are provided

  7. Improved Results for the H-2(d, n)(3) He Transverse Vector Polarization- Transfer Coefficient K-y(y)' (0 degrees) at Low Energies

    International Nuclear Information System (INIS)

    Roper, C.D.; Clegg, T.; Dunham, J.D.; Mendez, Anthony J. II; Tornow, W.; Walter, R.L.

    2010-01-01

    Measurements of the H-2(d, n)(3) He transverse vector polarization-transfer coefficient K-y(y)' at 0 degrees. are reported for 29 outgoing neutron energies between 3.94 and 8.47MeV. Our new results determine K-y(y)' (0 degrees) more accurately than previous data, especially for neutron energies below 5MeV. Low-energy data for this reaction are important both as a high-intensity source of highly polarized neutrons for nuclear physics studies with polarized neutron beams, and as a test of the emerging theoretical descriptions of the four-body system, where recently substantial progress has been made.

  8. Activity coefficients from molecular simulations using the OPAS method

    Science.gov (United States)

    Kohns, Maximilian; Horsch, Martin; Hasse, Hans

    2017-10-01

    A method for determining activity coefficients by molecular dynamics simulations is presented. It is an extension of the OPAS (osmotic pressure for the activity of the solvent) method in previous work for studying the solvent activity in electrolyte solutions. That method is extended here to study activities of all components in mixtures of molecular species. As an example, activity coefficients in liquid mixtures of water and methanol are calculated for 298.15 K and 323.15 K at 1 bar using molecular models from the literature. These dense and strongly interacting mixtures pose a significant challenge to existing methods for determining activity coefficients by molecular simulation. It is shown that the new method yields accurate results for the activity coefficients which are in agreement with results obtained with a thermodynamic integration technique. As the partial molar volumes are needed in the proposed method, the molar excess volume of the system water + methanol is also investigated.

  9. High power densities from high-temperature material interactions. [in thermionic energy conversion and metallic fluid heat pipes

    Science.gov (United States)

    Morris, J. F.

    1981-01-01

    Thermionic energy conversion (TEC) and metallic-fluid heat pipes (MFHPs), offering unique advantages in terrestrial and space energy processing by virtue of operating on working-fluid vaporization/condensation cycles that accept great thermal power densities at high temperatures, share complex materials problems. Simplified equations are presented that verify and solve such problems, suggesting the possibility of cost-effective applications in the near term for TEC and MFHP devices. Among the problems discussed are: the limitation of alkali-metal corrosion, protection against hot external gases, external and internal vaporization, interfacial reactions and diffusion, expansion coefficient matching, and creep deformation.

  10. Multi-dimensional conversion to the ion-hybrid mode

    International Nuclear Information System (INIS)

    Tracy, E.R.; Kaufman, A.N.; Brizard, A.J.; Morehead, J.J.

    1996-01-01

    We first demonstrate that the dispersion matrix for linear conversion of a magnetosonic wave to an ion-hybrid wave (as in a D-T plasma) can be congruently transformed to Friedland's normal form. As a result, this conversion can be represented as a two-step process of successive linear conversions in phase space. We then proceed to study the multi-dimensional case of tokamak geometry. After fourier transforming the toroidal dependence, we deal with the two-dimensional poloidal xy-plane and the two-dimensional k x k y -plane, forming a four-dimensional phase space. The dispersion manifolds for the magnetosonic wave [D M (x, k) = 0] and the ion-hybrid wave [D H (x, k) = 0] are each three-dimensional. (Their intersection, on which mode conversion occurs, is two-dimensional.) The incident magnetosonic wave (radiated by an antenna) is a two-dimensional set of rays (a lagrangian manifold): k(x) = ∇θ(x), with θ(x) the phase of the magnetosonic wave. When these rays pierce the ion-hybrid dispersion manifold, they convert to a set of ion-hybrid rays. Then, when those rays intersect the magnetosonic dispersion manifold, they convert to a set of open-quotes reflectedclose quotes magnetosonic rays. This set of rays is distinct from the set of incident rays that have been reflected by the inner surface of the tokamak plasma. As a result, the total destructive interference that can occur in the one-dimensional case may become only partial. We explore the implications of this startling phenomenon both analytically and geometrically

  11. The high-spin {sup 178m2}Hf isomer: production, chemical and isotopic separations, gamma spectrometry and internal conversion electrons spectrometry; L`isomere de haut spin {sup 178m2}Hf: production, separations chimiques et isotopiques, spectrometrie gamma et spectrometrie d`electrons de conversion interne

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J B

    1993-10-13

    The high-spin isometric state of the nucleus 178Hf is a challenge for new and exotic nuclear physics studies. With its long half-life of 31 years, the production of a reasonable micro-weight quantity, with an isometric to ground state ratio as high as 5 per cent, is now regularly performed by intensive irradiations of ytterbium targets with helium ions of 36 MeV. Using sur-enriched, at 99,998 per cent, ytterbium 176 that we have prepared at the PARIS mass separator, the isomer purity has been improved. Targets of such material but also of enriched stable isotopes of hafnium have been prepared by electro-spraying of methanolic and acetic solutions. By inelastic diffusion of protons and deuton on these targets, the energy of the first state of the rotation band built on the isomer has been measured. Isotopic separations of the isomer have been performed, with a yield greater than 20 per cent, by the use of isotopically pure hafnium 176 as carrier. The separated beam of the mass 178 allowed to record the complete hyperfine spectrum of the isomer and to measure, for the first time, the magnetic dipole moment and the electric quadrupole moment. Isomer targets, implanted in various materials like copper, iron and hafnium monocrystal, provide the opportunity to accurately measure gamma and internal conversion decay of this nuclei and so to precise the multipolarity mixing of all transitions from K=16{sup +} to K=8{sup -}. (author). 49 refs., 47 figs., 11 tabs.

  12. Measurement and modelling of mean activity coefficients of aqueous mixed electrolyte solution containing glycine

    Energy Technology Data Exchange (ETDEWEB)

    Dehghani, M.R. [Department of Chemical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of) ; Modarress, H. [Department of Chemical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of) ]. E-mail: hmodares@aut.ac.ir; Monirfar, M. [Department of Chemical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2006-08-15

    Electrochemical measurements were made on (H{sub 2}O + NaBr + K{sub 3}PO{sub 4} + glycine) mixtures at T = 298.15 K by using ion selective electrodes. The mean ionic activity coefficients of NaBr at molality 0.1 were determined at five K{sub 3}PO{sub 4} molalities (0.01, 0.03, 0.05, 0.07, and 0.1) mol . kg{sup -1}. The activity coefficients of glycine were evaluated from mean ionic activity coefficients of NaBr. The modified Pitzer equation was used to model the experimental data.

  13. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    Science.gov (United States)

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita

    2012-01-01

    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  14. Diffusion coefficients of paracetamol in aqueous solutions

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Barros, Marisa C.F.; Veríssimo, Luís M.P.; Santos, Cecilia I.A.V.; Cabral, Ana M.T.D.P.V.; Gaspar, Gualter D.; Esteso, Miguel A.

    2012-01-01

    Highlights: ► Mutual diffusion coefficients of paracetamol in aqueous dilute solutions. ► Influence of the thermodynamic factors on the variation of their mutual diffusion coefficients. ► Estimation of the mutual limiting diffusion coefficients of the molecular, D m 0 , and ionized forms, D ± 0 , of this drug. - Abstract: Binary mutual diffusion coefficients measured by the Taylor dispersion method, for aqueous solutions of paracetamol (PA) at concentrations from (0.001 to 0.050) mol·dm −3 at T = 298.15 K, are reported. From the Nernst–Hartley equation and our experimental results, the limiting diffusion coefficient of this drug and its thermodynamic factors are estimated, thereby contributing in this way to a better understanding of the structure of such systems and of their thermodynamic behaviour in aqueous solution at different concentrations.

  15. In-beam conversion electron spectroscopy using the SACRED array

    International Nuclear Information System (INIS)

    Jones, P.M.; Cann, K.J.; Cocks, J.F.C.; Jones, G.D.; Julin, R.; Schulze, B.; Smith, J.F.; Wilson, A.N.

    1997-01-01

    Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs

  16. Heat conduction coefficient and coefficient of linear thermal expansion of electric insulation materials for superconducting magnetic system

    International Nuclear Information System (INIS)

    Deev, V.I.; Sobolev, V.P.; Kruglov, A.B.; Pridantsev, A.I.

    1984-01-01

    Results of experimental investigation of heat conduction coefficient and coefficient of linear thermal expansion and thermal shrinkages of the STEF-1 textolite-glass widely used in superconducting magnetic systems as electric insulating and structural material are presented. Samples of two types have been died: sample axisa is perpendicular to a plae of fiberglass layers ad sample axis is parallel to a plane of fiberglass layers. Heat conduction coefficient was decreased almost a five times with temperature decrease from 300 up to 5K and was slightly dependent on a sample type. Temperature variation of linear dimensions in a sample of the first type occurs in twice as fast as compared to the sample of the second type

  17. Extraction of Dunham coefficients from Murrell-Sorbie parameters

    International Nuclear Information System (INIS)

    Lim Teikcheng

    2008-01-01

    A set of relationships between parameters of the Dunham and Murrell-Sorbie potential energy function is developed. By employing Taylor series expansion and comparison of terms arranged in increasing order of bond length, a set of Dunham coefficients is obtained as functions of Murrell- Sorbie parameters. The conversion functions reveal the importance of factorials in extracting Dunham coefficients from Murrell-Sorbie parameters. Plots of both functions, based on parameters of the latter, reveal good correlation near the equilibrium bond length for a group of diatomic molecules. Potential function relations, such as that shown in this paper, are useful when the preferred/reliable data is based on a potential function different from that adopted in available computational software. (orig.)

  18. Lead-free piezoelectric (K,Na)NbO3-based ceramic with planar-mode coupling coefficient comparable to that of conventional lead zirconate titanate

    Science.gov (United States)

    Ohbayashi, Kazushige; Matsuoka, Takayuki; Kitamura, Kazuaki; Yamada, Hideto; Hishida, Tomoko; Yamazaki, Masato

    2017-06-01

    We developed a (K,Na)NbO3-based lead-free piezoelectric ceramic with a KTiNbO5 system, (K1- x Na x )0.86Ca0.04Li0.02Nb0.85O3-δ-K0.85Ti0.85Nb1.15O5-BaZrO3-Fe2O3-MgO (K1- x N x N-NTK-FM). K1- x N x N-NTK-FM ceramic exhibits a very dense microstructure and a coupling coefficient of k p = 0.59, which is almost comparable to that of conventional lead zirconate titanate (PZT). The (K,Na)NbO3-based ceramic has the Γ15 mode for a wide x range. The nanodomains of orthorhombic (K,Na)NbO3 with the M3 mode coexist within the tetragonal Γ15 mode (K,Na)NbO3 matrix. Successive phase transition cannot occur with increasing x. The maximum k p is observed at approximately the minimum x required to generate the M3 mode phase. Unlike the behavior at the morphotropic phase boundary (MPB) in PZT, the characteristics of K1- x N x N-NTK-FM ceramic in this region changed moderately. This gentle phase transition seems to be a relaxor, although the diffuseness degree is not in line with this hypothesis. Furthermore, piezoelectric properties change from “soft” to “hard” upon the M3 mode phase aggregation.

  19. k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program: biological sample analysis

    International Nuclear Information System (INIS)

    Puerta, Daniel Correa

    2013-01-01

    The results obtained in the application of the k 0 -standardization method at LAN-IPEN for biological matrices analysis, by using the k 0 -IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and a of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197 Au- 96 Zr- 94 Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The U-score test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k 0 -INAA method at LAN-IPEN for biological sample analysis. (author)

  20. Radiation and penetration matrix elements for magnetic quadrupole transitions between Nilsson states in odd nuclei

    International Nuclear Information System (INIS)

    Feresin, A.P.; Guseva, I.S.

    1984-01-01

    Single-particle matrix elements for magnetic quadrupole gamma radiation in odd deformed nuclei, calculated with the aid of Nilsson-potential wave functions, are presented. Also given are the internal conversion penetration matrix elements, calculated in the same manner. The penetration matrix elements are needed to estimate the nuclear penetration parameter, which determines the deviation of experimental internal conversion coefficients from their standard values given in tables. Matrix elements are given for transitions between all pairs of Nilsson single-particle states with ΔN = 1 and ΔK = 0, 1, and 2 for the nuclear shells with 4< or =N< or =7 and for the two deformation values epsilon = 0.2 and 0.3

  1. Study of the influence of surfactants on the activity coefficients and mass transfer coefficients of methanol in aqueous mixtures by reversed-flow gas chromatography.

    Science.gov (United States)

    Kotsalos, Efthimios; Brezovska, Boryana; Sevastos, Dimitrios; Vagena, Artemis; Koliadima, Athanasia; Kapolos, John; Karaiskakis, George

    2017-11-17

    This work focuses on the influences of surfactants on the activity coefficients, γ, of methanol in binary mixtures with water, as well as on the mass transfer coefficients, k c , for the evaporation of methanol, which is a ubiquitous component in the troposphere, from mixtures of methanol with water at various surfactant's and methanol's concentrations. The technique used is the Reversed-Flow Gas Chromatography (R.F.G.C.), a version of Inverse Gas Chromatography, which allows determining both parameters by performing only one experiment for the k c parameter and two experiments for the γ parameter. The k c and γ values decrease in the presence of the three surfactants used (CTAB, SDS, TRITON X-100) at all methanol's and surfactant's concentrations. The decrease in the methanol's molar fraction, at constant number of surfactant films leads to a decrease in the k c and γ values, while the decrease in the surfactant's concentration, at constant methanol's molar fraction leads to an increase in both the k c and γ parameters. Mass transfer coefficients for the evaporation of methanol at the surfactant films, are also calculated which are approximately between 4 and 5 orders of magnitude larger than the corresponding mass transfer coefficients at the liquid films. Finally, thicknesses of the boundary layer of methanol in the mixtures of methanol with water were determined. The quantities found are compared with those given in the literature or calculated theoretically using various empirical equations. The precision of the R.F.G.C. method for measuring γ and k c parameters is approximately high (94.3-98.0%), showing that R.F.G.C. can be used with success not only for the thermodynamic study of solutions, but also for the interphase transport. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Partial inelasticity coefficients of negative pions in p, d, α, 12C + 12C and p, 12C + 181Ta collisions at 4.2 GeV/c per nucleon

    International Nuclear Information System (INIS)

    Olimov, K.K.; Olimov, K.; Gulamov, K.G.; Olimov, A.K.; Lutpullaev, S.L.; Yuldashev, B.S.; Haseeb, M.Q.

    2015-01-01

    The partial inelasticity coefficients of the negative pions were determined in minimum bias p, d, α, 12 C + 12 C and p, 12 C + 18 Ta collisions at 4.2A GeV/c taking into account the average number of participant nucleons of a projectile nucleus. In nucleus–nucleus collisions, the average values of partial inelasticity coefficients (〈K(π-)〉) of the negative pions did not depend on the mass numbers of projectile and target nuclei. Increase of 〈K(π - )〉 in going from p + 12 C to d, α, 12 C + 12 C collisions was due to an additional source of production of fast negative pions in nucleus–nucleus collisions — a charge exchange conversion of one or more neutrons of a projectile nucleus into a proton and π - . Linking the experimental results of the present analysis at intermediate energy with those obtained at high and ultra-high energies, it was concluded that the average values of partial inelasticity coefficients of pions in nucleon–nucleus and nucleus–nucleus collisions manifest a transitive behavior. At intermediate energies, the values of 〈K(π - )〉 were smaller by a factor of two and more as compared to those at high energies, and they increased further with increasing incident energy, reaching a plateau at E 0 > 100A GeV. (author)

  3. Conversion tables. Appendix I

    International Nuclear Information System (INIS)

    McKerrell, H.

    1975-01-01

    Tables are presented for the conversion of standard (5568 year half-life) C-14 dates to calendar years. The major part of the data converts C-14 dates to tree-ring years: additional data are given, based on the Egyptian historical curve. (U.K.)

  4. Quantum conversion

    OpenAIRE

    Mazilu, Michael

    2015-01-01

    ICOAM 2015 The electromagnetic momentum transferred transferred to scattering particles is proportional to the intensity of the incident fields, however, the momentum of single photons ℏk does not naturally appear in these classical expressions. Here, we discuss an alternative to Maxwell's stress tensor that renders the classical electromagnetic field momentum compatible to the quantum mechanical one. This is achieved through the introduction of the quantum conversion which allows the tran...

  5. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  6. Modeling internal wave generation by seamounts in oceans

    Science.gov (United States)

    Zhang, L.; Buijsman, M. C.; Comino, E. L.; Swinney, H.

    2017-12-01

    Recent global bathymetric data at 30 arc-sec resolution has revealed that there are 33,452 seamounts and 138,412 knolls in the oceans. To develop an estimate for the energy converted from tidal flow to internal gravity waves, we have conducted numerical simulations using the Massachusetts Institute of Technology circulation model (MITgcm) to compute the energy conversion by randomly distributed Gaussian-shaped seamounts. We find that for an isolated axisymmetric seamount of height 1100 m and radius 1600 m, which corresponds to the Wessel height-to-radius ratio 0.69, the conversion rate is 100 kW, assuming a tidal speed amplitude 1 cm/s, buoyancy frequency 1e-3 rad/s, and circularly polarized tidal motion, and taking into account the earth's rotation. The 100 kW estimate is about 60% less than the 3-D linear theory prediction because fluid goes around a seamount instead of over it. Our estimate accounts the suppression of energy conversion due to wave interference at the generation site of closely spaced seamounts. We conclude that for randomly distributed Gaussian seamounts of varying widths and separations, separated on average by 18 km as in the oceans, wave interference reduces the energy conversion by seamounts by only about 16%. This result complements previous studies of wave interference for 2-D ridges.

  7. Transport Properties of Bulk Thermoelectrics—An International Round-Robin Study, Part I: Seebeck Coefficient and Electrical Resistivity

    Science.gov (United States)

    Wang, Hsin; Porter, Wallace D.; Böttner, Harald; König, Jan; Chen, Lidong; Bai, Shengqiang; Tritt, Terry M.; Mayolet, Alex; Senawiratne, Jayantha; Smith, Charlene; Harris, Fred; Gilbert, Patricia; Sharp, Jeff W.; Lo, Jason; Kleinke, Holger; Kiss, Laszlo

    2013-04-01

    Recent research and development of high-temperature thermoelectric materials has demonstrated great potential for converting automobile exhaust heat directly into electricity. Thermoelectrics based on classic bismuth telluride have also started to impact the automotive industry by enhancing air-conditioning efficiency and integrated cabin climate control. In addition to engineering challenges of making reliable and efficient devices to withstand thermal and mechanical cycling, the remaining issues in thermoelectric power generation and refrigeration are mostly materials related. The dimensionless figure of merit, ZT, still needs to be improved from the current value of 1.0 to 1.5 to above 2.0 to be competitive with other alternative technologies. In the meantime, the thermoelectric community could greatly benefit from the development of international test standards, improved test methods, and better characterization tools. Internationally, thermoelectrics have been recognized by many countries as a key component for improving energy efficiency. The International Energy Agency (IEA) group under the Implementing Agreement for Advanced Materials for Transportation (AMT) identified thermoelectric materials as an important area in 2009. This paper is part I of the international round-robin testing of transport properties of bulk thermoelectrics. The main foci in part I are the measurement of two electronic transport properties: Seebeck coefficient and electrical resistivity.

  8. Explanation of low efficiency droop in semipolar $(20\\bar 2\\bar 1)$ InGaN/GaN LEDs through evaluation of carrier recombination coefficients

    OpenAIRE

    Monavarian, Morteza; Rashidi, Arman; Aragon, Andrew A.; Oh, Sang H.; Nami, Mohsen; DenBaars, Steve P.; Feezell, Daniel F.

    2017-01-01

    We report the carrier dynamics and recombination coefficients in single-quantum-well semipolar $(20\\bar 2\\bar 1)$ InGaN/GaN light-emitting diodes emitting at 440 nm with 93% peak internal quantum efficiency. The differential carrier lifetime is analyzed for various injection current densities from 5 $A/cm^2$ to 10 $kA/cm^2$, and the corresponding carrier densities are obtained. The coupling of internal quantum efficiency and differential carrier lifetime vs injected carrier density ($n$) enab...

  9. Determination of diffusion coefficients of hydrogen in fused silica between 296 and 523 K by Raman spectroscopy and application of fused silica capillaries in studying redox reactions

    Science.gov (United States)

    Shang, L.; Chou, I-Ming; Lu, W.; Burruss, Robert; Zhang, Y.

    2009-01-01

    Diffusion coefficients (D) of hydrogen in fused silica capillaries (FSC) were determined between 296 and 523 K by Raman spectroscopy using CO2 as an internal standard. FSC capsules (3.25 × 10−4 m OD, 9.9 × 10−5 m ID, and ∼0.01 m long) containing CO2 and H2were prepared and the initial relative concentrations of hydrogen in these capsules were derived from the Raman peak-height ratios between H2 (near 587 cm−1) and CO2 (near 1387 cm−1). The sample capsules were then heated at a fixed temperature (T) at one atmosphere to let H2 diffuse out of the capsule, and the changes of hydrogen concentration were monitored by Raman spectroscopy after quench. This process was repeated using different heating durations at 296 (room T), 323, 375, 430, 473, and 523 K; the same sample capsule was used repeatedly at each temperature. The values of D (in m2 s−1) in FSC were obtained by fitting the observed changes of hydrogen concentration in the FSC capsule to an equation based on Fick’s law. Our D values are in good agreement with the more recent of the two previously reported experimental data sets, and both can be represented by:lnD=-(16.471±0.035)-44589±139RT(R2=0.99991)">lnD=-(16.471±0.035)-44589±139RT(R2=0.99991)where R is the gas constant (8.3145 J/mol K), T in Kelvin, and errors at 1σ level. The slope corresponds to an activation energy of 44.59 ± 0.14 kJ/mol.The D in FSC determined at 296 K is about an order of magnitude higher than that in platinum at 723 K, indicating that FSC is a suitable membrane for hydrogen at temperature between 673 K and room temperature, and has a great potential for studying redox reactions at these temperatures, especially for systems containing organic material and/or sulphur.

  10. A study of core electron binding energies in technetium-99m complexes by internal conversion electron spectroscopy

    International Nuclear Information System (INIS)

    Burke, J.F.; Archer, C.M.; Wei Chiu, K.; Latham, I.A.; Egdell, R.G.

    1991-01-01

    Core electron binding energies in a series of 99m Tc complexes have been studied by internal conversion electron spectroscopy (ICES) in a conventional x-ray photoelectron spectrometer. In both 3d and 3p regions, a chemical shift of about 1 eV is observed per unit increase in oxidation state. The role of ICES in characterizing radiopharmaceutical agents is illustrated with studies of some novel 99m Tc-phosphine complexes that have been developed for myocardial perfusion imaging. (author)

  11. On the influence of the finite thickness of sources on the internal conversion lines observed in beta spectrometer

    International Nuclear Information System (INIS)

    Pecequilo, B.R.S.

    1976-01-01

    Electron lines are simulated by a Monte Carlo method in a digital computer in order to obtain an analytical formula to calculate the energy and the relative intensity of electron conversion lines when observed by beta spectrometry. The electrons come from the own thickness of the source. Computer program that simulate these lines is presented. In order to test the method, a direct comparison of the K-line of Hg-198 with the same line as simulated by the computer, is done [pt

  12. K-shell absorption jump factors and jump ratios in elements between Tm ( Z = 69) and Os ( Z = 76) derived from new mass attenuation coefficient measurements

    Science.gov (United States)

    Kaya, Necati; Tıraşoğlu, Engin; Apaydın, Gökhan; Aylıkcı, Volkan; Cengiz, Erhan

    2007-08-01

    The K-shell absorption jump factors and jump ratios were derived from new mass attenuation coefficients measured using an energy dispersive X-ray fluorescence (EDXRF) spectrometer for Tm, Yb elements being Tm 2O 3, Yb 2O 3 compounds and pure Lu, Hf, Ta, W, Re and Os. The measurements, in the region 56-77 keV, were done in a transmission geometry utilizing the K α1 , K α2 , K β1 and K β2 X- rays from different secondary source targets (Yb, Ta, Os, W, Re and Ir, etc.) excited by the 123.6 keV γ-photons from an 57Co annular source and detected by an Ultra-LEGe solid state detector with a resolution of 150 eV at 5.9 keV. Experimental results have been compared with theoretically calculated values. The measured values of Tm, Yb, Lu, Hf, Ta, W, Re and Os are reported here for the first time.

  13. K-shell absorption jump factors and jump ratios in elements between Tm (Z = 69) and Os (Z = 76) derived from new mass attenuation coefficient measurements

    International Nuclear Information System (INIS)

    Kaya, Necati; Tirasoglu, Engin; Apaydin, Goekhan; Aylikci, Volkan; Cengiz, Erhan

    2007-01-01

    The K-shell absorption jump factors and jump ratios were derived from new mass attenuation coefficients measured using an energy dispersive X-ray fluorescence (EDXRF) spectrometer for Tm, Yb elements being Tm 2 O 3 , Yb 2 O 3 compounds and pure Lu, Hf, Ta, W, Re and Os. The measurements, in the region 56-77 keV, were done in a transmission geometry utilizing the K α1 , K α2 , K β1 and K β2 X- rays from different secondary source targets (Yb, Ta, Os, W, Re and Ir, etc.) excited by the 123.6 keV γ-photons from an 57 Co annular source and detected by an Ultra-LEGe solid state detector with a resolution of 150 eV at 5.9 keV. Experimental results have been compared with theoretically calculated values. The measured values of Tm, Yb, Lu, Hf, Ta, W, Re and Os are reported here for the first time

  14. Analytical solution for the mode conversion equations with steep exponential density profiles

    International Nuclear Information System (INIS)

    Alava, M.J.; Heikkinen, J.A.

    1992-01-01

    A general analytical solution for the converted power from the fast magnetosonic wave to an ion Bernstein wave in a magnetized plasma with an exponential steeply increasing density profile is given in the closed form. The solution covers both the conversion at the lower-hybrid resonance and the conversion through the density gradient for small parallel wave numbers. As an application, the conversion coefficients at the scrape-off layer plasma are estimated in the context of ion cyclotron heating of a tokamak plasma

  15. On computing Laplace's coefficients and their derivatives.

    Science.gov (United States)

    Gerasimov, I. A.; Vinnikov, E. L.

    The algorithm of computing Laplace's coefficients and their derivatives is proposed with application of recurrent relations. The A.G.M.-method is used for the calculation of values L0(0), L0(1). The FORTRAN-program corresponding to the algorithm is given. The precision control was provided with numerical integrating by Simpsons method. The behavior of Laplace's coefficients and their third derivatives whith varying indices K, n for fixed values of the α-parameter is presented graphically.

  16. Measurement and prediction of aromatic solute distribution coefficients for aqueous-organic solvent systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.R.; Luthy, R.G.

    1984-06-01

    Experimental and modeling activities were performed to assess techniques for measurement and prediction of distribution coefficients for aromatic solutes between water and immiscible organic solvents. Experiments were performed to measure distribution coefficients in both clean water and wastewater systems, and to assess treatment of a wastewater by solvent extraction. The theoretical portions of this investigation were directed towards development of techniques for prediction of solute-solvent/water distribution coefficients. Experiments were performed to assess treatment of a phenolic-laden coal conversion wastewater by solvent extraction. The results showed that solvent extraction for recovery of phenolic material offered several wastewater processing advantages. Distribution coefficients were measured in clean water and wastewater systems for aromatic solutes of varying functionality with different solvent types. It was found that distribution coefficients for these compounds in clean water systems were not statistically different from distribution coefficients determined in a complex coal conversion process wastewater. These and other aromatic solute distribution coefficient data were employed for evaluation of modeling techniques for prediction of solute-solvent/water distribution coefficients. Eight solvents were selected in order to represent various chemical classes: toluene and benzene (aromatics), hexane and heptane (alkanes), n-octanol (alcohols), n-butyl acetate (esters), diisopropyl ether (ethers), and methylisobutyl ketone (ketones). The aromatic solutes included: nonpolar compounds such as benzene, toluene and naphthalene, phenolic compounds such as phenol, cresol and catechol, nitrogenous aromatics such as aniline, pyridine and aminonaphthalene, and other aromatic solutes such as naphthol, quinolinol and halogenated compounds. 100 references, 20 figures, 34 tables.

  17. Activity coefficients and excess Gibbs' free energy of some binary mixtures formed by p-cresol at 95.23 kPa

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, T.E. Vittal [Properties Group, Chemical Engineering Laboratory, Indian Institute of Chemical Technology, Hyderabad 500 007 (India); Venkanna, N. [Swamy Ramanandateertha Institute of Science and Technology, Hyderabad 508 004 (India); Kumar, Y. Naveen [Swamy Ramanandateertha Institute of Science and Technology, Hyderabad 508 004 (India); Ashok, K. [Swamy Ramanandateertha Institute of Science and Technology, Hyderabad 508 004 (India); Sirisha, N.M. [Swamy Ramanandateertha Institute of Science and Technology, Hyderabad 508 004 (India); Prasad, D.H.L. [Properties Group, Chemical Engineering Laboratory, Indian Institute of Chemical Technology, Hyderabad 500 007 (India)]. E-mail: dasika@iict.res.in

    2007-07-15

    Bubble point temperatures at 95.23 kPa, over the entire composition range are measured for the binary mixtures formed by p-cresol with 1,2-dichloroethane, 1,1,2,2-tetrachloroethane trichloroethylene, tetrachloroethylene, and o- , m- , and p-xylenes, making use of a Swietoslawski-type ebulliometer. Liquid phase mole fraction (x {sub 1}) versus bubble point temperature (T) measurements are found to be well represented by the Wilson model. The optimum Wilson parameters are used to calculate the vapor phase composition, activity coefficients, and excess Gibbs free energy. The results are discussed.

  18. Converse flexoelectric effect in comb electrode piezoelectric microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Zhiyuan, E-mail: shenyuan675603@gmail.com [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore (Singapore); Chen, Wei [Microelectronics Centre, School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore (Singapore)

    2012-04-09

    We demonstrate the converse flexoelectric effect in a lead zirconate titanate microbeam. The fringe electric field of a comb electrode induces converse flexoelectric responses in uniformly poled and depoled beams. The simulated electric field distribution shows that bending of the beam is induced by piezoelectric and μ{sub 11}, μ{sub 12} flexoelectric coefficients. Simulations indicate that piezoelectric displacement occurs in different directions in the two opposite poled samples while flexoelectric displacement remains the same. This finding is verified by the displacement measurement results. -- Highlights: ► We demonstrate the converse flexoelectric effect in a PZT microbeam. ► Beams with upward and downward poling states are fabricated by MEMS technique. ► Converse flexoelectric deformation is induced by the fringe field. ► Electric field distribution is calculated by finite element analysis. ► The simulation results are verified by impedance and displacement measurements.

  19. Moderator temperature coefficient in BWR core

    International Nuclear Information System (INIS)

    Naito, Yoshitaka

    1977-01-01

    Temperature dependences of infinite multiplication factor k sub(infinity) and neutron leakage from the core must be examined for estimation of moderator temperature coefficient. Temperature dependence on k sub(infinity) has been investigated by many researchers, however, the dependence on neutron leakage of a BWR with cruciformed control rods has hardly been done. Because there are difficulties and necessity on calculations of three space dimensional and multi-energy groups neutron distribution in a BWR core. In this study, moderator temperature coefficients of JPDR-II (BWR) core were obtained by calculation with DIFFUSION-ACE, which is newly developed three-dimensional multi-group computer code. The results were compared with experimental data measured from 20 to 275 0 C of the moderator temperature and the good agreement was obtained between calculation and measurement. In order to evaluate neutron leakage from the core, the other two calculations were carried out, adjusting criticality by uniform absorption rate and by material buckling. The former underestimated neutron leakage and the latter overestimated it. Discussion on the results shows that in order to estimate the temperature coefficient of BWR, neutron leakage must be evaluated precisely, therefore the calculation at actual pattern of control rods is necessary. (auth.)

  20. The Power of Cooperation in International Paleoclimate Science: Examples from the PAGES 2k Network and the Ocean2k Working Group

    Science.gov (United States)

    Addison, J. A.

    2015-12-01

    The Past Global Changes (PAGES) project of IGBP and Future Earth supports research to understand the Earth's past environment to improve future climate predictions and inform strategies for sustainability. Within this framework, the PAGES 2k Network was established to provide a focus on the past 2000 years, a period that encompasses Medieval Climate Anomaly warming, Little Ice Age cooling, and recent anthropogenically-forced climate change. The results of these studies are used for testing earth system models, and for understanding decadal- to centennial-scale variability, which is needed for long-term planning. International coordination and cooperation among the nine regional Working Groups that make up the 2k Network has been critical to the success of PAGES 2k. The collaborative approach is moving toward scientific achievements across the regional groups, including: (i) the development of a community-driven open-access proxy climate database; (ii) integration of multi-resolution proxy records; (iii) development of multivariate climate reconstructions; and (iv) a leap forward in the spatial resolution of paleoclimate reconstructions. The last addition to the 2k Network, the Ocean2k Working Group has further innovated the collaborative approach by: (1) creating an open, receptive environment to discuss ideas exclusively in the virtual space; (2) employing an array of real-time collaborative software tools to enable communication, group document writing, and data analysis; (3) consolidating executive leadership teams to oversee project development and manage grassroots-style volunteer pools; and (4) embracing the value-added role that international and interdisciplinary science can play in advancing paleoclimate hypotheses critical to understanding future change. Ongoing efforts for the PAGES 2k Network are focused on developing new standards for data quality control and archiving. These tasks will provide the foundation for new and continuing "trans-regional" 2k

  1. Rate coefficients for hydrogen abstraction reaction of pinonaldehyde

    Indian Academy of Sciences (India)

    The H abstraction reaction from the –CHO group was found to be the most dominant reaction channelamong all the possible reaction pathways and its corresponding rate coefficient at 300 K is kEckart's unsymmetrical= 3.86 ×10-10 cm3 molecule-1 s-1. Whereas the channel with immediate lower activation energy is the ...

  2. A software to edit voxel phantoms and to calculate conversion coefficients for radiation protection

    International Nuclear Information System (INIS)

    Vieira, J.W.; Stosic, B.; Lima, F.R.A.; Kramer, R.; Santos, A.M.; Lima, V.J.M.

    2005-01-01

    The MAX and FAX phantoms have been developed based on a male and female, respectively, adult body from ICRP and coupled to the Monte Carlo code (EGS4). These phantoms permit the calculating of the equivalent dose in organs and tissues of the human body for the radiation protection purposes . In the constructing of these anthropomorphic models, the software developed called FANTOMAS, which performs tasks as file format conversion, filtering 2D and 3D images, exchange of identifying numbers of organs, body mass adjustments based in volume, resampling of 2D and 3D images, resize images, preview consecutive slices of the phantom, running computational models of exposure FANTOMA/EGS4 and viewing graphics of conversion factors between equivalent dose and a measurable dosimetric quantity. This paper presents the main abilities of FANTOMAS and uses the MAX and/or FAX to exemplify some procedures

  3. Transport coefficients of a dissociating gas

    International Nuclear Information System (INIS)

    Lebed', I.V.

    1987-01-01

    The calculation of the transport coefficients of a dissociating gas involves fundamental difficulties which arise when the internal degrees of freedom of the molecules are taken strictly into account. In practical calculations extensive use is made of the approximation in the context of which the dependence of a diffusion velocity of the molecule on its internal state is totally neglected. In this case the expressions for the stress tensor and the diffusion velocities coincide with the corresponding expressions for a mixture of structureless particles; in the expression for the heat flux the diffusion transport of internal energy is taken only approximately into account. Here, analytic expressions for the diffusion velocities, heat flux and stress tensor are obtained without introducing simplifying assumptions. The calculation method is based on an approximate method of calculating the transport coefficients of a multicomponent mixture of structureless particles. The relations obtained are analyzed and compared with the existing results; their accuracy is estimated. A closed system of equations of gas dynamics is presented for a number of cases of practical importance

  4. Towards an international authoritative system for coordination and management of a unique recommended k0-NAA database

    International Nuclear Information System (INIS)

    De Corte, F.

    2010-01-01

    This paper describes the evolution of the database in k 0 -standardized neutron activation analysis (k 0 -NAA), ranging from its full supervision by the founders of the k 0 -method at the Institute for Nuclear Sciences (INW)/Gent and the Central Research Institute for Physics (KFKI)/Budapest (from about the mid 1970s up to the early 1990s), to the present situation (roughly speaking starting with the first k 0 Users Workshop in 1992) where an increasing number of researchers from institutes allover the world are reporting on their experimental work aiming at the improvement and extension of the existing database. Although these individual contributions are undoubtedly commendable, the resulting fragmentary data sets leave behind important questions with respect to interpretation, evaluation, integration and recommendation, as illustrated with the (extreme) example of 131 Ba. This situation urgently calls for establishing and managing an international authoritative system for the coordination and quality control of a unique database with recommended data for k 0 -NAA, considering such parameters as accuracy, traceability and consistency. In the present paper, it is proposed to entrust this task to a standing 'Reference k 0 -Data Subcommittee' of the k 0 -ISC (k 0 International Scientific Committee).

  5. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain.

    Science.gov (United States)

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A

    2018-01-01

    Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials

  6. Internal services simulation control in 220/110kV power transformer station Mintia

    Science.gov (United States)

    Ciulica, D.; Rob, R.

    2018-01-01

    The main objectives in developing the electric transport and distribution networks infrastructure are satisfying the electric energy demand, ensuring the continuity of supply to customers, minimizing electricity losses in the transmission and distribution networks of public interest. This paper presents simulations in functioning of the internal services system 400/230 V ac in the 220/110 kV power transformer station Mintia. Using simulations in Visual Basic, the following premises are taken into consideration. All the ac consumers of the 220/110 kV power transformer station Mintia will be supplied by three 400/230 V transformers for internal services which can mutual reserve. In case of damaging at one transformer, the others are able to assume the entire consumption using automatic release of reserves. The simulation program studies three variants in which the continuity of supply to customers are ensured. As well, by simulations, all the functioning situations are analyzed in detail.

  7. Neutronics substantiation of possibility for conversion of the WWR-K reactor core to operation with low-enriched fuel

    International Nuclear Information System (INIS)

    Arinkin, F.M.; Gizatulin, Sh.H.; Zhantikin, T.M.; Koltochnik, S.N.; Takibaev, A.Zh.; Talanov, S.V.; Chakrov, P.V.; Chekushina, L.V.

    2002-01-01

    The studies are aimed to calculation and experimental justification of possibility for conversion of the WWR-R reactor core to low-enriched nuclear fuel (the 19.75-% enrichment in isotope U-235), resulting in reducing the risk of non-sanctioned proliferation of nuclear materials which can be used as weapons materials. The analysis of available published data, related to problem of reduction of enrichment in the fuel used in research thermal reactors, has been carried out. Basing on the analysis results, reference fuel compositions have been chosen, in particular, uranium dioxide (UO 2 ) in aluminum master form and the UA1 4 alloy. Preliminary calculations have shown that, with the WWR-K reactor core preserved existing critical characteristics (the fuel composition: UA1 4 ), the uranium concentration in the fuel element is to be increased by a factor of 2.0-2.2, being impossible technologically. The calculations have been performed by means of the Monte Carlo computational codes. The program of optimal conversion of the WWR-K reactor core to low-enriched fuel has been developed, including: development of calculation models of the reactor core, composed of various designs of fuel elements and fuel assemblies (FA), on a base of corresponding computational codes (diffusion, statistical, etc.); implementation of experiments in the zero-power reactor (critical assembly) with the WWR-C-type FA, in view of correction of the computational constants used in calculations; implementation of reactor core neutronics calculations, in view of selection of the U-235 optimal content in the low-enriched fuel elements and choice of FA reload strategy at the regime of reactor core after burning; determination of the fuel element specification; determination of the critical and operational loads for the reactor core composed of rod/tubular fuel elements; calculation of the efficiency of the protection control system effectors, optimization of its composition, number and locations in the

  8. Atmospheric Extinction Coefficients in the Ic Band for Several Major International Observatories: Results from the BiSON Telescopes, 1984-2016

    Science.gov (United States)

    Hale, S. J.; Chaplin, W. J.; Davies, G. R.; Elsworth, Y. P.; Howe, R.; Lund, M. N.; Moxon, E. Z.; Thomas, A.; Pallé, P. L.; Rhodes, E. J., Jr.

    2017-09-01

    Over 30 years of solar data have been acquired by the Birmingham Solar Oscillations Network (BiSON), an international network of telescopes used to study oscillations of the Sun. Five of the six BiSON telescopes are located at major observatories. The observational sites are, in order of increasing longitude: Mount Wilson (Hale) Observatory (MWO), California, USA; Las Campanas Observatory, Chile; Observatorio del Teide, Izaña, Tenerife, Canary Islands; the South African Astronomical Observatory, Sutherland, South Africa; Carnarvon, Western Australia; and the Paul Wild Observatory, Narrabri, New South Wales, Australia. The BiSON data may be used to measure atmospheric extinction coefficients in the {{{I}}}{{c}} band (approximately 700-900 nm), and presented here are the derived atmospheric extinction coefficients from each site over the years 1984-2016.

  9. Lipid–water partition coefficients and correlations with uptakes by algae of organic compounds

    International Nuclear Information System (INIS)

    Hung, Wei-Nung; Chiou, Cary T.; Lin, Tsair-Fuh

    2014-01-01

    Graphical abstract: - Highlights: • Partition coefficients of contaminants with lipid triolein (K tw ) are measured. • Measured K tw values are nearly the same as the respective K ow . • Sorption of the contaminants to a dry algal powder is similarly measured. • Algal uptake of a compound occurs primarily by partition into the algal lipid. - Abstract: In view of the scarcity of the lipid–water partition coefficients (K tw ) for organic compounds, the log K tw values for many environmental contaminants were measured using ultra-pure triolein as the model lipid. Classes of compounds studied include alkyl benzenes, halogenated benzenes, short-chain chlorinated hydrocarbons, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides. In addition to log K tw determination, the uptakes of these compounds from water by a dry algal species were measured to evaluate the lipid effect on the algal uptake. The measured log K tw are closely related to their respective log K ow (octanol–water), with log K ow = 1.9 to 6.5. A significant difference is observed between the present and early measured log K tw for compounds with log K ow > ∼5, which is attributed to the presence and absence of a triolein microemulsion in water affecting the solute partitioning. The observed lipid-normalized algae–water distribution coefficients (log K aw/lipid ) are virtually identical to the respective log K tw values, which manifests the dominant lipid-partition effect of the compounds with algae

  10. Potassium Capture by Kaolin, Part 2: K2CO3, KCI, and K2SO4

    DEFF Research Database (Denmark)

    Wang, Guoliang; Jensen, Peter Arendt; Wu, Hao

    2018-01-01

    residence time on the reaction was investigated. The results showed that the K-capture level (C-K) (g potassium reacted by per g kaolin available) of K2CO3 and KCI by kaolin generally followed the equilibrium predictions at temperatures above 1100 degrees C, when using a kaolin particle size of D50 = 5.......47 mu m and a residence time of 1.2 s. This revealed that a nearly full conversion was obtained without kinetic or transport limitations at the conditions applied. At 800 and 900 degrees C, the measured conversions were lower than the equilibrium predictions, indicating that the reactions were either...

  11. Estimating varying coefficients for partial differential equation models.

    Science.gov (United States)

    Zhang, Xinyu; Cao, Jiguo; Carroll, Raymond J

    2017-09-01

    Partial differential equations (PDEs) are used to model complex dynamical systems in multiple dimensions, and their parameters often have important scientific interpretations. In some applications, PDE parameters are not constant but can change depending on the values of covariates, a feature that we call varying coefficients. We propose a parameter cascading method to estimate varying coefficients in PDE models from noisy data. Our estimates of the varying coefficients are shown to be consistent and asymptotically normally distributed. The performance of our method is evaluated by a simulation study and by an empirical study estimating three varying coefficients in a PDE model arising from LIDAR data. © 2017, The International Biometric Society.

  12. Activity coefficients at infinite dilution for hydrocarbons in furfuryl alcohol at T=(278.15 and 298.15) K, determined by g.l.c

    International Nuclear Information System (INIS)

    Kozlowska, Marta K.; Letcher, Trevor M.; Domanska, Urszula

    2004-01-01

    The potential of the polar solvent, furfuryl alcohol, as a solvent in the separation of aromatics from aliphatics and other hydrocarbons, has been investigated by measuring activity coefficients at infinite dilution. The activity coefficients at infinite dilution for some alkanes, cycloalkanes, alkenes, alkynes and benzene in furfuryl alcohol have been determined by g.l.c. at T=(278.15 and 298.15) K. The method used is we believe, a more controlled and reliable method than the alternative pre-saturation method. The results have been used to calculate the selectivity factor and hence predict the potential for furfuryl alcohol as a solvent in separating aromatic compounds from aliphatic compounds and other hydrocarbons using extractive distillation. The results have been compared to the recently published work on a related polar solvent - furfural. The excess enthalpies of mixing at infinite dilution have also been calculated

  13. Rate Coefficient Measurements of the Reaction CH3 + O2 = CH3O + O

    Science.gov (United States)

    Hwang, S. M.; Ryu, Si-Ok; DeWitt, K. J.; Rabinowitz, M. J.

    1999-01-01

    Rate coefficients for the reaction CH3 + O2 = CH3O + O were measured behind reflected shock waves in a series of lean CH4-O2-Ar mixtures using hydroxyl and methyl radical diagnostics. The rate coefficients are well represented by an Arrhenius expression given as k = (1.60(sup +0.67, sub -0.47 ) x 10(exp 13) e(-15813 +/- 587 K/T)/cubic cm.mol.s. This expression, which is valid in the temperature range 1575-1822 K, supports the downward trend in the rate coefficients that has been reported in recent determinations. All measurements to date, including the present study, have been to some extent affected by secondary reactions. The complications due to secondary reactions, choice of thermochemical data, and shock-boundary layer interactions that affect the determination of the rate coefficients are examined.

  14. Rate Coefficient Measurements of the Reaction CH3+O2+CH3O+O

    Science.gov (United States)

    Hwang, S. M.; Ryu, Si-Ok; DeWitt, K. J.; Rabinowitz, M. J.

    1999-01-01

    Rate coefficients for the reaction CH3 + O2 = CH3O + O were measured behind reflected shock waves in a series of lean CH4-O2-Ar mixtures using hydroxyl and methyl radical diagnostics. The rate coefficients are well represented by an Arrhenius expression given as k = (1.60(sup +0.67, -0.47)) X 10(exp 13) exp(- 15813 +/- 587 K/T)cc/mol s. This expression, which is valid in the temperature range 1575-1822 K, supports the downward trend in the rate coefficients that has been reported in recent determinations. All measurements to date, including the present study, have been to some extent affected by secondary reactions. The complications due to secondary reactions, choice of thermochemical data, and shock-boundary layer interactions that affect the determination of the rate coefficients are examined.

  15. Engineering quadratic nonlinear photonic crystals for frequency conversion of lasers

    Science.gov (United States)

    Chen, Baoqin; Hong, Lihong; Hu, Chenyang; Zhang, Chao; Liu, Rongjuan; Li, Zhiyuan

    2018-03-01

    Nonlinear frequency conversion offers an effective way to extend the laser wavelength range. Quadratic nonlinear photonic crystals (NPCs) are artificial materials composed of domain-inversion structures whose sign of nonlinear coefficients are modulated with desire to implement quasi-phase matching (QPM) required for nonlinear frequency conversion. These structures can offer various reciprocal lattice vectors (RLVs) to compensate the phase-mismatching during the quadratic nonlinear optical processes, including second-harmonic generation (SHG), sum-frequency generation and the cascaded third-harmonic generation (THG). The modulation pattern of the nonlinear coefficients is flexible, which can be one-dimensional or two-dimensional (2D), be periodic, quasi-periodic, aperiodic, chirped, or super-periodic. As a result, these NPCs offer very flexible QPM scheme to satisfy various nonlinear optics and laser frequency conversion problems via design of the modulation patterns and RLV spectra. In particular, we introduce the electric poling technique for fabricating QPM structures, a simple effective nonlinear coefficient model for efficiently and precisely evaluating the performance of QPM structures, the concept of super-QPM and super-periodically poled lithium niobate for finely tuning nonlinear optical interactions, the design of 2D ellipse QPM NPC structures enabling continuous tunability of SHG in a broad bandwidth by simply changing the transport direction of pump light, and chirped QPM structures that exhibit broadband RLVs and allow for simultaneous radiation of broadband SHG, THG, HHG and thus coherent white laser from a single crystal. All these technical, theoretical, and physical studies on QPM NPCs can help to gain a deeper insight on the mechanisms, approaches, and routes for flexibly controlling the interaction of lasers with various QPM NPCs for high-efficiency frequency conversion and creation of novel lasers.

  16. Feasibility survey on international cooperation for high efficiency energy conversion technology in fiscal 1993

    Science.gov (United States)

    1994-03-01

    Following cooperative researches on fuel cell jointly conducted by NEDO and EGAT (Electricity Generating Authority of Thailand), the survey on international cooperation relating to high efficiency energy conversion technology was carried out for the ASEAN countries. The paper summed up the results of the survey. The study of the international cooperation is made for the following three items: a program for periodical exchange of information with EGAT, a project for cooperative research on phosphoric acid fuel cell in Indonesia, and a project for cooperative research with EGAT on electric power storage by advanced battery. In Malaysia, which is small in scale of state, part of the Ministry of Energy, Telecommunication and Posts is only in charge of the energy issue. Therefore, the situation is that they cannot answer well to many items of research/development cooperation brought in from Japan. The item of medium- and long-term developmental research in the Philippines is about the problems which are seen subsequently in the Manila metropolitan area where the problem of outage is being settled. Accordingly, it is essential to promote the cooperative research, well confirming policies and systems of the Ministry of Energy and the national electricity corporation.

  17. Estimation of soil-soil solution distribution coefficient of radiostrontium using soil properties.

    Science.gov (United States)

    Ishikawa, Nao K; Uchida, Shigeo; Tagami, Keiko

    2009-02-01

    We propose a new approach for estimation of soil-soil solution distribution coefficient (K(d)) of radiostrontium using some selected soil properties. We used 142 Japanese agricultural soil samples (35 Andosol, 25 Cambisol, 77 Fluvisol, and 5 others) for which Sr-K(d) values had been determined by a batch sorption test and listed in our database. Spearman's rank correlation test was carried out to investigate correlations between Sr-K(d) values and soil properties. Electrical conductivity and water soluble Ca had good correlations with Sr-K(d) values for all soil groups. Then, we found a high correlation between the ratio of exchangeable Ca to Ca concentration in water soluble fraction and Sr-K(d) values with correlation coefficient R=0.72. This pointed us toward a relatively easy way to estimate Sr-K(d) values.

  18. Preliminary Experimental Study on Pressure Loss Coefficients of Exhaust Manifold Junction

    Directory of Open Access Journals (Sweden)

    Xiao-lu Lu

    2014-01-01

    Full Text Available The flow characteristic of exhaust system has an important impact on inlet boundary of the turbine. In this paper, high speed flow in a diesel exhaust manifold junction was tested and simulated. The pressure loss coefficient of the junction flow was analyzed. The steady experimental results indicated that both of static pressure loss coefficients L13 and L23 first increased and then decreased with the increase of mass flow ratio of lateral branch and public manifold. The total pressure loss coefficient K13 always increased with the increase of mass flow ratio of junctions 1 and 3. The total pressure loss coefficient K23 first increased and then decreased with the increase of mass flow ratio of junctions 2 and 3. These pressure loss coefficients of the exhaust pipe junctions can be used in exhaust flow and turbine inlet boundary conditions analysis. In addition, simulating calculation was conducted to analyze the effect of branch angle on total pressure loss coefficient. According to the calculation results, total pressure loss coefficient was almost the same at low mass flow rate of branch manifold 1 but increased with lateral branch angle at high mass flow rate of branch manifold 1.

  19. Isopiestic determination of the osmotic coefficients and Pitzer model representation for Li{sub 2}B{sub 4}O{sub 7}(aq) at T=298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Aiyun [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China); Hei Long Jiang Science and Technology College, Ha' erbin (China); Yao Yan [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China)]. E-mail: yanyao@pub.xaonline.com; Li Lijuan [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China); Song Pengsheng [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China)

    2005-02-01

    Isopiestic molalities and water activities have been measured for aqueous Li{sub 2}B{sub 4}O{sub 7} solutions from (0.0275 to 2.9397) mol.kg{sup -1} at T=298.15 K by isopiestic method, using an improved apparatus. These measurements have extended into the very dilute and the supersaturated molality region. Two types of osmotic coefficients of {phi}{sub S} and {phi}{sub E} were determined. {phi}{sub S} is based on the stoichiometric molalities of the solute Li{sub 2}B{sub 4}O{sub 7}(aq), and {phi}{sub E} is based on equilibrium molalities based on consideration of the equilibrium speciation of H3BO3,B(OH)4-,B3O3(OH)4-,andB4O5(OH)42- in the Li{sub 2}B{sub 4}O{sub 7}(aq) solutions. The stoichiometric equilibrium constants K{sub mi} for the aqueous speciation reactions were estimated. Three types of representations of the osmotic coefficients for the (Li{sub 2}B{sub 4}O{sub 7}+H{sub 2}O) system with the ion-interaction models based on Pitzer's equations of osmotic coefficients with minor modifications were presented: the model (I) for representation of the data of {phi}{sub S} with four parameters based on considering the ion-interactions between two ionic species of Li+andB4O72-, the model (II) for representation of the data of {phi}{sub E} based on considering the equilibrium speciation with 18 parameters, and the model (III) simplified from model (II) with six ion-interaction parameters estimated. The reasonable agreements between the experimental osmotic coefficient data and those calculated using the models above were obtained with the standard deviations of 0.0215, 0.0055, and 0.0150 for the three models, respectively. The thermodynamic osmotic coefficient properties for the complex system containing polymetric boron anions and lithium may be explained by use of the Pitzer ion-interaction model with minor modifications in combination with speciation reaction equilibria.

  20. Absorption and emission from mode conversion theory

    International Nuclear Information System (INIS)

    Swanson, D.G.

    1995-02-01

    The effects of mode conversion theory on emission have led to some surprising results. The classical expressions were originally derived from models which did not include mode conversion or its attendant reflection. When mode conversion was included, the first surprise was that the transmission coefficient is totally independent of absorption and due exclusively to tunneling. The other surprise is that the observed emission arises from two distinct sources, one direct, and one from an indirect Bernstein wave source which is partially converted in the cyclotron layer to outgoing electromagnetic waves, with the net result that mode conversion cancels out for the electron case. The only corrections to electron cyclotron emission are then due to reflection effects, and these have been shown to be small for laboratory plasmas, leading to the validation of the classical formula, but via an entirely new paradigm in its interpretation. This paper includes a summary of the absorption process for electron cyclotron harmonics, and reviews the emission physics, including both potential error estimates and a discussion of the spatial emission source distribution

  1. 75 FR 36455 - SSE Telecom, Inc., Strategic Alliance Group, Inc., (n/k/a CruiseCam International, Inc...

    Science.gov (United States)

    2010-06-25

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] SSE Telecom, Inc., Strategic Alliance Group, Inc., (n/k/a CruiseCam International, Inc.), Stratasec, Inc., Superfly Advertising, Inc. (f/k/a Morlex... a lack of current and accurate information concerning the securities of Strategic Alliance Group...

  2. Transport coefficients in high-temperature ionized air flows with electronic excitation

    Science.gov (United States)

    Istomin, V. A.; Oblapenko, G. P.

    2018-01-01

    Transport coefficients are studied in high-temperature ionized air mixtures using the modified Chapman-Enskog method. The 11-component mixture N2/N2+/N /N+/O2/O2+/O /O+/N O /N O+/e- , taking into account the rotational and vibrational degrees of freedom of molecules and electronic degrees of freedom of both atomic and molecular species, is considered. Using the PAINeT software package, developed by the authors of the paper, in wide temperature range calculations of the thermal conductivity, thermal diffusion, diffusion, and shear viscosity coefficients for an equilibrium ionized air mixture and non-equilibrium flow conditions for mixture compositions, characteristic of those in shock tube experiments and re-entry conditions, are performed. For the equilibrium air case, the computed transport coefficients are compared to those obtained using simplified kinetic theory algorithms. It is shown that neglecting electronic excitation leads to a significant underestimation of the thermal conductivity coefficient at temperatures higher than 25 000 K. For non-equilibrium test cases, it is shown that the thermal diffusion coefficients of neutral species and the self-diffusion coefficients of all species are strongly affected by the mixture composition, while the thermal conductivity coefficient is most strongly influenced by the degree of ionization of the flow. Neglecting electronic excitation causes noticeable underestimation of the thermal conductivity coefficient at temperatures higher than 20 000 K.

  3. Determination of the temperature coefficients and the kinetic parameters for the HTTR safety analysis

    International Nuclear Information System (INIS)

    Tokuhara, K.; Nakata, T.; Murata, I.; Yamashita, K.; Shindo, R.

    1991-01-01

    This report describes the calculational methods which were employed to determine the temperature coefficients and the kinetic parameters for the safety analysis in the HTTR (High Temperature Engineering Test Reactor). The temperature coefficients (doppler, moderator temperature) and the kinetic parameters (prompt neutron life time; l, effective delayed neutron fraction; β eff) are important for the point model core dynamic analysis and should be evaluated properly. The temperature coefficients were calculated by the whole core model. Doppler coefficient was evaluated under the conditions of all control rods withdrawn and the uniform change of fuel temperature. The minimum and the maximum value of the evaluated doppler coefficients in a burnup cycle are -4.6x10 -5 and -1.5x10 -5 ΔK/K/deg. C respectively. The moderator temperature coefficient was evaluated under the conditions of all control rods withdrawn and the uniform change of moderator temperature. The minimum and the maximum value of the evaluated moderator temperature coefficients in a burnup cycle are -17.1x10 -5 and 0.99x10 -5 ΔK/K/deg. C respectively. In spite of positive moderator temperature coefficient, the power coefficient is always negative. Therefore the HTTR possesses inherent power-suppressing feed back characteristic in all operating condition. We surveyed the effects of the Xe existence, the control rods existence, the fuel temperature and the region in which the temperature was changed on the moderator temperature coefficients. The kinetic parameters were calculated by the perturbation method with the whole core model. The minimum and the maximum value of the evaluated effective delayed neutron fraction (β eff) are 0.0047 and 0.0065 respectively. These of the evaluated prompt neutron life time (l) are 0.67 and 0.78 ms respectively. We have surveyed the effects of the fuel depletion and the core power level on these parameters, and considered these effects on the kinetic parameters. From

  4. Some Methods for Calculating Competition Coefficients from Resource-Utilization Spectra.

    Science.gov (United States)

    Schoener, Thomas W

    When relative frequencies of resource kinds in the diet are known, the competition coefficient giving the effect of competitor j on i may be computed as \\documentclass{aastex} \\usepackage{amsbsy} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{bm} \\usepackage{mathrsfs} \\usepackage{pifont} \\usepackage{stmaryrd} \\usepackage{textcomp} \\usepackage{portland,xspace} \\usepackage{amsmath,amsxtra} \\usepackage{wasysym} \\pagestyle{empty} \\DeclareMathSizes{10}{9}{7}{6} \\begin{document}$$\\alpha_{ij}=\\left(\\frac{T_{j}}{T_{i}}\\right)\\left[\\frac{{\\sum\\limits_{k=1}^{m}}(d_{ik}/f_{k})\\:(d_{jk}/f_{k})\\:b_{ik}}{\\sum\\limits_{k=1}^{m}(d_{ik}/f_{k})^{2}\\:b_{ik}}\\right],$$\\end{document} where T j /T i = the ratio of the number of items consumed by an individual of competitor j to that consumed by an individual of competitor i, measured over an interval of time that includes all regular fluctuations in consumption for both species; d ik = the frequency of resource k in the diet of competitor i (and similarly for d jk ); f k = the standing frequency of resource k in the environment; b ik = the net calories gained by an individual of competitor i from an item of resource k, or more approximately the calories contained in an item of resource k, or still more approximately the weight or volume of an item of resource k; and the summations are taken over all resources eaten by at least one of the competing species. The coefficient follows from MacArthur's (1968) consumer-resource system when the ratio of the carrying capacity to intrinsic rate of increase is constant for all resources. When relative frequencies of time spent foraging in habitat kinds are known, the competition coefficient may be computed as \\documentclass{aastex} \\usepackage{amsbsy} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{bm} \\usepackage{mathrsfs} \\usepackage{pifont} \\usepackage{stmaryrd} \\usepackage{textcomp} \\usepackage{portland,xspace} \\usepackage

  5. K-homology and K-cohomology constructions of relations

    International Nuclear Information System (INIS)

    Abd El-Sattar, A. Dabbour; Bayoumy, F.M.

    1990-08-01

    One of the important homology (cohomology) theories, based on systems of covering of the space, is the homology (cohomology) theory of relations. In the present work, by using the idea of K-homology and K-cohomology groups different varieties of the Dowker's theory are introduced and studied. These constructions are defined on the category of pairs of topological spaces and over a pair of coefficient groups. (author). 14 refs

  6. A Comparison of Coolant Options for Brayton Power Conversion Heat Rejection Systems

    International Nuclear Information System (INIS)

    Siamidis, John; Mason, Lee

    2006-01-01

    This paper describes potential heat rejection design concepts for Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) and surface power applications. The Brayton Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Sodium potassium (NaK) and H2O are two coolant working fluids that have been investigated in the design of a pumped loop and heat pipe space HRS. In general NaK systems are high temperature (300 to 1000 K) low pressure systems, and H2O systems are low temperature (300 to 600 K) high pressure systems. NaK is an alkali metal with health and safety hazards that require special handling procedures. On the other hand, H2O is a common fluid, with no health hazards and no special handling procedures. This paper compares NaK and H2O for the HRS pumped loop coolant working fluid. A detailed excel analytical model, HRS O pt, was developed to evaluate the various HRS design parameters. It is capable of analyzing NaK or H2O coolant, parallel or series flow configurations, and numerous combinations of other key parameters (heat pipe spacing, diameter and radial flux, radiator facesheet thickness, fluid duct system pressure drop, system rejected power, etc.) of the HRS. This paper compares NaK against water for the HRS coolant working fluid with respect to the relative mass, performance, design and implementation issues between the two fluids

  7. Thermodynamics of proton binding and weak (Cl−, Na+ and K+) species formation, and activity coefficients of 1,2-dimethyl-3-hydroxypyridin-4-one (deferiprone)

    International Nuclear Information System (INIS)

    Bretti, Clemente; Cigala, Rosalia Maria; Crea, Francesco; Lando, Gabriele; Sammartano, Silvio

    2014-01-01

    Graphical abstract: Trend of the deferiprone protonation constant (log K 1 H ) vs. ionic strength (in the molal concentration scale) in NaCl (□), KCl (Δ) and (CH 3 ) 4 NCl (○), at T = 298.15 K. - Highlights: • Thermodynamics, solubility and distribution of deferiprone in NaCl, KCl and (CH 3 ) 4 NCl. • Deferiprone total solubility is 0.100 mol · dm −3 in pure water and shows salting out. • The protonation process is entropic for the first step and enthalpic for the second. • Debye–Hückel, SIT and Pitzer approaches used for modelling of protonation constants. • Formation constants of three weak species were determined, Nadef, Kdef and H 2 defCl. - Abstract: The acid base properties of 1,2-dimethyl-3-hydroxypyridin-4-one (also known as deferiprone, def, figure 1), together with the solubility and the distribution ratio have been studied potentiometrically at different temperatures and ionic strengths in NaCl, KCl and in (CH 3 ) 4 NCl aqueous solutions. The total solubility of deferiprone is fairly high (0.100 mol · dm −3 in pure water) and decreases with increasing salt concentration (salting out effect); this behaviour is greater in NaCl than in (CH 3 ) 4 NCl aqueous solutions. From the analysis of the solubility and the distribution measurements it was possible to determine the Setschenow and the activity coefficients of the neutral species. Deferiprone shows two protonation steps, whose protonation constants are logK 1 H =10.088 and logK 2 H =3.656 at infinite dilution and T = 298.15 K. The ionic strength dependence of the protonation constants was interpreted both in terms of variation of the activity coefficients, using the Debye–Hückel, the SIT (Specific ion Interaction Theory) and the Pitzer approaches, or considering the formation of weak species with the ions of the supporting electrolyte (e.g. Na + , K + and Cl − ). Moreover, temperature gradients were provided for the two protonation constants. The stepwise protonation enthalpy

  8. Coherent phase control of internal conversion in pyrazine

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Robert J., E-mail: rjgordon@uic.edu; Singha, Sima; Zhao, Youbo [Department of Chemistry (m/c 111), University of Illinois at Chicago, Chicago, Illinois 60680-7061 (United States); Hu, Zhan [Institute of Atomic and Molecular Physics, Jilin University, Changchun 130021 (China); Seideman, Tamar [Department of Chemistry, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208 (United States); Sukharev, Maxim [Science and Mathematics Faculty, College of Letters and Sciences, Arizona State University, Mesa, Arizona 85212 (United States)

    2015-04-14

    Shaped ultrafast laser pulses were used to study and control the ionization dynamics of electronically excited pyrazine in a pump and probe experiment. For pump pulses created without feedback from the product signal, the ion growth curve (the parent ion signal as a function of pump/probe delay) was described quantitatively by the classical rate equations for internal conversion of the S{sub 2} and S{sub 1} states. Very different, non-classical behavior was observed when a genetic algorithm (GA) employing phase-only modulation was used to minimize the ion signal at some pre-determined target time, T. Two qualitatively different control mechanisms were identified for early (T < 1.5 ps) and late (T > 1.5 ps) target times. In the former case, the ion signal was largely suppressed for t < T, while for t ≫ T, the ion signal produced by the GA-optimized pulse and a transform limited (TL) pulse coalesced. In contrast, for T > 1.5 ps, the ion growth curve followed the classical rate equations for t < T, while for t ≫ T, the quantum yield for the GA-optimized pulse was much smaller than for a TL pulse. We interpret the first type of behavior as an indication that the wave packet produced by the pump laser is localized in a region of the S{sub 2} potential energy surface where the vertical ionization energy exceeds the probe photon energy, whereas the second type of behavior may be described by a reduced absorption cross section for S{sub 0} → S{sub 2} followed by incoherent decay of the excited molecules. Amplitude modulation observed in the spectrum of the shaped pulse may have contributed to the control mechanism, although this possibility is mitigated by the very small focal volume of the probe laser.

  9. Damage coefficient and defect level of copper-contaminated silicon N+P diode

    International Nuclear Information System (INIS)

    Usami, A.; Kato, Y.

    1975-01-01

    The damage coefficient at 298 0 K of copper-contaminated N + P diodes is smaller than that of non-contaminated ones. In these copper-contaminated samples, the higher the bulk resistivity is, the smaller is the damage coefficient. For non-contaminated diodes, the damage coefficient of samples of pulled bulk crystals is smaller than that of floating zone crystals, and the higher bulk resistivity diodes have smaller damage coefficient. At 217 0 K measurement, the effect of copper-contamination on the damage coefficient could not be observed. The energy levels of defects introduced by gamma ray irradiation are approximately0.30 eV, and approximately0.28 eV with non-contaminated FZ 135 ohm-cm and CZ 10 ohm-cm bulk samples, respectively. In copper-contaminated samples, approximately0.60 eV and approximately0.45 eV are obtained as the defect energy levels for FZ 135 ohm-cm and CZ 10 ohm-cm bulk samples. (U.S.)

  10. Lipid–water partition coefficients and correlations with uptakes by algae of organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Wei-Nung [Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu 30011, Taiwan (China); Chiou, Cary T., E-mail: carychio@mail.ncku.edu.tw [Department of Environmental Engineering and Sustainable Environment Research Laboratory, National Cheng Kung University, Tainan 70101, Taiwan (China); U.S. Geological Survey, Denver Federal Center, Denver, CO 80225 (United States); Lin, Tsair-Fuh, E-mail: tflin@mail.ncku.edu.tw [Department of Environmental Engineering and Sustainable Environment Research Laboratory, National Cheng Kung University, Tainan 70101, Taiwan (China)

    2014-08-30

    Graphical abstract: - Highlights: • Partition coefficients of contaminants with lipid triolein (K{sub tw}) are measured. • Measured K{sub tw} values are nearly the same as the respective K{sub ow}. • Sorption of the contaminants to a dry algal powder is similarly measured. • Algal uptake of a compound occurs primarily by partition into the algal lipid. - Abstract: In view of the scarcity of the lipid–water partition coefficients (K{sub tw}) for organic compounds, the log K{sub tw} values for many environmental contaminants were measured using ultra-pure triolein as the model lipid. Classes of compounds studied include alkyl benzenes, halogenated benzenes, short-chain chlorinated hydrocarbons, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides. In addition to log K{sub tw} determination, the uptakes of these compounds from water by a dry algal species were measured to evaluate the lipid effect on the algal uptake. The measured log K{sub tw} are closely related to their respective log K{sub ow} (octanol–water), with log K{sub ow} = 1.9 to 6.5. A significant difference is observed between the present and early measured log K{sub tw} for compounds with log K{sub ow} > ∼5, which is attributed to the presence and absence of a triolein microemulsion in water affecting the solute partitioning. The observed lipid-normalized algae–water distribution coefficients (log K{sub aw/lipid}) are virtually identical to the respective log K{sub tw} values, which manifests the dominant lipid-partition effect of the compounds with algae.

  11. Solid/liquid partition coefficients (K{sub d}) and plant/soil concentration ratios (CR) for selected soils, tills and sediments at Forsmark

    Energy Technology Data Exchange (ETDEWEB)

    Sheppard, Steve (ECOMatters Inc. (Canada)); Sohlenius, Gustav (Sveriges geologiska undersoekning (Sweden)); Omberg, Lars-Gunnar (ALS Scandinavia AB (Sweden)); Borgiel, Mikael (Sveriges Vattenekologer AB (Sweden)); Grolander, Sara (Facilia AB (Sweden)); Norden, Sara (Svensk Kaernbraenslehantering AB (Sweden))

    2011-11-15

    Solid/liquid partition coefficients (K{sub d}) are used to indicate the relative mobility of radionuclides and elements of concern from nuclear fuel waste, as well as from other sources. To indicate the uptake of radionuclides in biota concentration ratios (CR) between soil and biota are used. This report summarized K{sub d} data for regolith and marine sediments based on concentrations of 69 indigenous stable elements measured from samples collected at the Forsmark site and CR data concerning cereals growing on these soils. The samples included 50 regolith samples from agricultural land and wetlands, 8 samples of till collected at different depths, and two marine sediment samples. In addition, cereal grains, stems and roots were collected from 4 sites for calculation of CRs. The regolith samples represented the major 5 deposits, which can be used as arable land, at the site (clayey till, glacial clay, clay gyttja and peat (cultivated and undisturbed)). K{sub d} values were generally lower for peat compared to clay soils. There were also clear differences in K{sub d} resulting from differences in soil chemistry within each regolith type. Soil pH was the most important factor, and K{sub d} values for many elements were lower in acidic clay soils compared to basic clay soils. Although there were only a few samples of sandy till and marine sediment, the K{sub d} values were generally consistent with the corresponding regolith K{sub d} values. Of the different cereal parts the grain always had the lowest CR. In most cases, the root CR was significantly higher than the grain CR, whereas only for a few elements were the grain and stem CR values different

  12. International købelov (CISG)

    DEFF Research Database (Denmark)

    Gomard, Bernhard; Henschel, René Franz

    Commentary in Danish on the 1980 United Nations Convention on the International Sale of Goods (CISG)......Commentary in Danish on the 1980 United Nations Convention on the International Sale of Goods (CISG)...

  13. Validation of conversion between mini-mental state examination and montreal cognitive assessment.

    Science.gov (United States)

    Lawton, Michael; Kasten, Meike; May, Margaret T; Mollenhauer, Brit; Schaumburg, Martina; Liepelt-Scarfone, Inga; Maetzler, Walter; Vollstedt, Eva-Juliane; Hu, Michele T M; Berg, Daniela; Ben-Shlomo, Yoav

    2016-04-01

    Harmonizing data across cohorts is important for validating findings or combining data in meta-analyses. We replicate and validate a previous conversion of MoCA to MMSE in PD. We used five studies with 1,161 PD individuals and 2,091 observations measured with both the MoCA and MMSE. We compared a previously published conversion table using equipercentile equating with log-linear smoothing to our internally derived scores. Both conversions found good agreement within and across the studies when comparing true and converted MMSE (mean difference: 0.05; standard deviation: 1.84; median difference: 0; interquartile range: -1 to 1, using internal conversion). These results show that one can get a reliable and valid conversion between two commonly used measures of cognition in PD studies. These approaches need to be applied to other scales and domains to enable large-scale collaborative analyses across multiple PD cohorts. © 2016 The Authors. International Parkinson and Movement Disorder Society.

  14. Demonstration of efficient full-aperture type I/type II third harmonic conversion on Nova

    International Nuclear Information System (INIS)

    Wegner, P.J.; Henesian, M.A.; Marchi, F.T.; Speck, D.R.

    1988-01-01

    The ten arms of the Nova laser system readily deliver 22.5 kJ of third harmonic radiation in 1-ns pulses to targets for fusion experiments. Frequency conversion experiments conducted on a single arm have produced >7.5 kJ of 3ω radiation in longer (2.5-ns) pulses at the output of a Nova crystal array with 15 kJ of 1ω drive. Equivalent on-target energies (40-60 kJ) in 2-3-ns pulses is available at target chamber center when the laser disks in the output section of the Nova amplifier are replaced with new high-damage threshold glass. The remaining issue facing frequency conversion on Nova is to demonstrate similar 3-ω energy (>40 kJ) on-target at shorter (1-ns) pulse lengths with controlled pulse shape at 1→ drive energies up to 9 kJ. Frequency conversion to 40 kJ of 3→ with precisely shaped pulses is required for future experiments. The authors assembled a full-aperture (74-cm) array of these crystals to test on an arm outfitted with the new laser glass. Measurements of conversion efficiency, pulse time history, and optical quality of the converted beam are reported

  15. Quantum mechanical study of the proton exchange in the ortho-para H2 conversion reaction at low temperature.

    Science.gov (United States)

    Honvault, P; Jorfi, M; González-Lezana, T; Faure, A; Pagani, L

    2011-11-14

    Ortho-para H(2) conversion reactions mediated by the exchange of a H(+) proton have been investigated at very low energy for the first time by means of a time independent quantum mechanical (TIQM) approach. State-to-state probabilities and cross sections for H(+) + H(2) (v = 0, j = 0,1) processes have been calculated for a collision energy, E(c), ranging between 10(-6) eV and 0.1 eV. Differential cross sections (DCSs) for H(+) + H(2) (v = 0, j = 1) → H(+) + H(2) (v' = 0, j' = 0) for very low energies only start to develop a proper global minimum around the sideways scattering direction (θ≈ 90°) at E(c) = 10(-3) eV. Rate coefficients, a crucial information required for astrophysical models, are provided between 10 K and 100 K. The relaxation ortho-para process j = 1 → j' = 0 is found to be more efficient than the j = 0 → j' = 1 conversion at low temperatures, in line with the extremely small ratio between the ortho and para species of molecular hydrogen predicted at the temperature of interstellar cold molecular clouds. The results obtained by means of a statistical quantum mechanical (SQM) model, which has previously proved to provide an adequate description of the dynamics of the title reactions at a higher collision energy regime, have been compared with the TIQM results. A reasonable good agreement has been found with the only exception of the DCSs for the H(+) + H(2) (v = 0, j = 1) → H(+) + H(2) (v' = 0, j' = 0) process at very low energy. SQM cross sections are also slightly below the quantum results. Estimates for the rate coefficients, in good accord with the TIQM values, are a clear improvement with respect to pioneering statistical studies on the reaction.

  16. Effect of linear and non-linear components in the temperature dependences of thermoelectric properties on the energy conversion efficiency

    International Nuclear Information System (INIS)

    Yamashita, Osamu

    2009-01-01

    The new thermal rate equations were built up by taking the linear and non-linear components in the temperature dependences of the Seebeck coefficient α, the electrical resistivity ρ and thermal conductivity κ of a thermoelectric (TE) material into the thermal rate equations on the assumption that their temperature dependences are expressed by a quadratic function of temperature T. The energy conversion efficiency η for a single TE element was formulated using the new thermal rate ones proposed here. By applying it to the high-performance half-Heusler compound, the non-linear component in the temperature dependence of α among those of the TE properties has the greatest effect on η, so that η/η 0 was increased by 11% under the condition of T = 510 K and ΔT = 440 K, where η 0 is a well-known conventional energy conversion efficiency. It was thus found that the temperature dependences of TE properties have a significant influence on η. When one evaluates the accurate achievement rate of η exp obtained experimentally for a TE generator, therefore, η exp should be compared with η the estimated from the theoretical expression proposed here, not with η 0 , particularly when there is a strong non-linearity in the temperature dependence of TE properties.

  17. 75 FR 6397 - AMC USA, Inc. v. International First Service S.A. a/k/a IFS S.A, its Agents, Affiliated, Related...

    Science.gov (United States)

    2010-02-09

    ... Service USA, Inc. a/k/a IFS USA, Inc. d/b/a Global Wine Logistics USA Inc. a/k/a GWL USA, Inc., and Global... Wine Logistics USA Inc. a/k/a GWL USA, Inc. (``GWL USA''); Anita McNeil; International First Service... FEDERAL MARITIME COMMISSION [Docket No. 10-01] AMC USA, Inc. v. International First Service S.A. a...

  18. The HD+ dissociative recombination rate coefficient at low temperature

    Directory of Open Access Journals (Sweden)

    Wolf A.

    2015-01-01

    Full Text Available The effect of the rotational temperature of the ions is considered for low-energy dissociative recombination (DR of HD+. Merged beams measurements with HD+ ions of a rotational temperature near 300 K are compared to multichannel quantum defect theory calculations. The thermal DR rate coefficient for a Maxwellian electron velocity distribution is derived from the merged-beams data and compared to theoretical results for a range of rotational temperatures. Good agreement is found for the theory with 300 K rotational temperature. For a low-temperature plasma environment where also the rotational temperature assumes 10 K, theory predicts a considerably higher thermal DR rate coefficient. The origin of this is traced to predicted resonant structures of the collision-energy dependent DR cross section at few-meV collision energies for the particular case of HD+ ions in the rotational ground state.

  19. Defining the Ecological Coefficient of Performance for an Aircraft Propulsion System

    Science.gov (United States)

    Şöhret, Yasin

    2018-05-01

    The aircraft industry, along with other industries, is considered responsible these days regarding environmental issues. Therefore, the performance evaluation of aircraft propulsion systems should be conducted with respect to environmental and ecological considerations. The current paper aims to present the ecological coefficient of performance calculation methodology for aircraft propulsion systems. The ecological coefficient performance is a widely-preferred performance indicator of numerous energy conversion systems. On the basis of thermodynamic laws, the methodology used to determine the ecological coefficient of performance for an aircraft propulsion system is parametrically explained and illustrated in this paper for the first time. For a better understanding, to begin with, the exergy analysis of a turbojet engine is described in detail. Following this, the outputs of the analysis are employed to define the ecological coefficient of performance for a turbojet engine. At the end of the study, the ecological coefficient of performance is evaluated parametrically and discussed depending on selected engine design parameters and performance measures. The author asserts the ecological coefficient of performance to be a beneficial indicator for researchers interested in aircraft propulsion system design and related topics.

  20. Measurement and modeling of interface heat transfer coefficients

    International Nuclear Information System (INIS)

    Rollett, A.D.; Lewis, H.D.; Dunn, P.S.

    1985-01-01

    The results of preliminary work on the modeling and measurement of the heat transfer coefficients of metal/mold interfaces is reported. The system investigated is the casting of uranium in graphite molds. The motivation for the work is primarily to improve the accuracy of process modeling of prototype mold designs at the Los Alamos Foundry. The evolution in design of a suitable mold for unidirectional solidification is described, illustrating the value of simulating mold designs prior to use. Experiment indicated a heat transfer coefficient of 2 kW/m 2 /K both with and without superheat. It was possible to distinguish between solidification due to the mold and that due to radiative heat loss. This permitted an experimental estimate of the emissivity, epsilon = 0.2, of the solidified metal

  1. Distribution coefficients for chemical components of a coal-oil/water system

    Energy Technology Data Exchange (ETDEWEB)

    Picel, K C; Stamoudis, V C; Simmons, M S

    1988-09-01

    Distribution coefficients (K/sub D/) were measured by equilibrating a coal oil comparative reference material (CRM-1) with water and then separating the oil and water phases. Aqueous phase concentrations were determined by direct analysis of this phase, while organic phase concentrations were determined from the original oil composition by difference. The log K/sub D/ values obtained for acidic and basic components were generally <3, while those for the neutral components ranged from 3 to 6. For aromatic hydrocarbons, strong correlations were observed between log K/sub D/ and log S/sub w/ (water solubility), and between log K/sub D/ and log K/sub o//sub w/ (octanol/water partition coefficient). Alkylated benzenes had significantly higher K/sub D/s than did unsubstituted aromatics of similar molecular weight. Examination of homologs revealed an increase of 0.307 log K/sub D/ units per additional carbon atom for polynuclear aromatic hydrocarbons having from 10 to 16 carbons. Alkyl substituent effects determined for various sets of homologs ranged from 0.391 to 0.466 log K/sub d/ units per -CH/sub 2/- group added. 38 refs., 5 figs., 7 tabs.

  2. Assessments of conversion coefficients between equivalent dose and accumulated activity using pre-dose scanning images of patients subjected to radioiodine treatment and the Fax/Egs4 computational model

    International Nuclear Information System (INIS)

    Lopes Filho, Ferdinand de J.; Vieira, Jose W.; Andrade Lima, Fernando R. de

    2008-01-01

    The radioiodine is a technique for treatment of thyroid cancer. In this technique, the patients are submitted to the incorporation of the radioactive substance sodium iodide (Na 131 I), which reacts with physiologically metastasis, thyroid tissue remains of and other organs and tissues of the human body. The locations of these reactions are known as areas of highest concentration, hipercaptured areas, hiperconcentrator areas, 'hot areas' or organ-sources and are viewed through images of nuclear medicine scan known as pre-dose (front and rear). To obtain these images, the patient receives, orally, a quantity of 131 I with low activity (± 74 MBq) and is positioned in the chamber of flicker. According to the attendance of hot areas shown in the images, the doctor determines the nuclear activity to be administered in treatment. This analysis is purely qualitative. In this study, the scanning images of pre-dose were adjusted to the dimensions of FAX voxel phantom, and the hot areas correspond to internal sources of the proposed model. Algorithms were developed to generate particles (photons and electrons) in these regions of the FAX. To estimate the coefficients of conversions between equivalent dose and accumulated activity in major radiosensitive organs, FAX and algorithms source were coupled to the Monte Carlo EGS4 code (Electron Gamma Shower, version 4). With these factors is possible to estimate the equivalent doses in the radiosensitive organs and tissues of patients as long as is know the activity administered and the half-life of organic sources. (author)

  3. Calculation of noise attenuation coefficient for leaks in the system sodium-water

    International Nuclear Information System (INIS)

    Yugaj, V.S.; Kozlov, F.A.; Sorokina, T.G.

    1986-01-01

    In this report the authors present the calculation results for sound attenuation coefficient on hydrogen bubbles in sodium and show a calculation method of attenuation coefficient for different temperatures of sodium in the 1-200 kHz range frequencies [fr

  4. Application of lag-k autocorrelation coefficient and the TGA signals approach to detecting and quantifying adulterations of extra virgin olive oil with inferior edible oils

    Energy Technology Data Exchange (ETDEWEB)

    Torrecilla, Jose S., E-mail: jstorre@quim.ucm.es [Department of Chemical Engineering, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain); Garcia, Julian; Garcia, Silvia; Rodriguez, Francisco [Department of Chemical Engineering, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain)

    2011-03-04

    The combination of lag-k autocorrelation coefficients (LCCs) and thermogravimetric analyzer (TGA) equipment is defined here as a tool to detect and quantify adulterations of extra virgin olive oil (EVOO) with refined olive (ROO), refined olive pomace (ROPO), sunflower (SO) or corn (CO) oils, when the adulterating agents concentration are less than 14%. The LCC is calculated from TGA scans of adulterated EVOO samples. Then, the standardized skewness of this coefficient has been applied to classify pure and adulterated samples of EVOO. In addition, this chaotic parameter has also been used to quantify the concentration of adulterant agents, by using successful linear correlation of LCCs and ROO, ROPO, SO or CO in 462 EVOO adulterated samples. In the case of detection, more than 82% of adulterated samples have been correctly classified. In the case of quantification of adulterant concentration, by an external validation process, the LCC/TGA approach estimates the adulterant agents concentration with a mean correlation coefficient (estimated versus real adulterant agent concentration) greater than 0.90 and a mean square error less than 4.9%.

  5. Application of lag-k autocorrelation coefficient and the TGA signals approach to detecting and quantifying adulterations of extra virgin olive oil with inferior edible oils

    International Nuclear Information System (INIS)

    Torrecilla, Jose S.; Garcia, Julian; Garcia, Silvia; Rodriguez, Francisco

    2011-01-01

    The combination of lag-k autocorrelation coefficients (LCCs) and thermogravimetric analyzer (TGA) equipment is defined here as a tool to detect and quantify adulterations of extra virgin olive oil (EVOO) with refined olive (ROO), refined olive pomace (ROPO), sunflower (SO) or corn (CO) oils, when the adulterating agents concentration are less than 14%. The LCC is calculated from TGA scans of adulterated EVOO samples. Then, the standardized skewness of this coefficient has been applied to classify pure and adulterated samples of EVOO. In addition, this chaotic parameter has also been used to quantify the concentration of adulterant agents, by using successful linear correlation of LCCs and ROO, ROPO, SO or CO in 462 EVOO adulterated samples. In the case of detection, more than 82% of adulterated samples have been correctly classified. In the case of quantification of adulterant concentration, by an external validation process, the LCC/TGA approach estimates the adulterant agents concentration with a mean correlation coefficient (estimated versus real adulterant agent concentration) greater than 0.90 and a mean square error less than 4.9%.

  6. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies.

    Science.gov (United States)

    Farkas, Árpád; Balásházy, Imre

    2015-04-01

    A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. A Note On Signs Of Fourier Coefficients Of Two Cusp Forms

    Indian Academy of Sciences (India)

    10

    Abstract. Kohnen and Sengupta showed that if two Hecke eigen cusp forms of weight k1 and k2 respectively with 1 < k1 < k2 over. Γ0(N ), have totally real algebraic Fourier coefficients {a(n)} and. {b(n)} respectively for n ≥ 1 with a(1) = 1 = b(1), then there exists an element σ of the absolute Galois group Gal(Q/Q) such.

  8. Reliability and mass analysis of dynamic power conversion systems with parallel or standby redundancy

    Science.gov (United States)

    Juhasz, Albert J.; Bloomfield, Harvey S.

    1987-01-01

    A combinatorial reliability approach was used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis was also performed, specifically for a 100-kWe nuclear Brayton power conversion system with parallel redundancy. Although this study was done for a reactor outlet temperature of 1100 K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

  9. Reliability and mass analysis of dynamic power conversion systems with parallel of standby redundancy

    Science.gov (United States)

    Juhasz, A. J.; Bloomfield, H. S.

    1985-01-01

    A combinatorial reliability approach is used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis is also performed, specifically for a 100 kWe nuclear Brayton power conversion system with parallel redundancy. Although this study is done for a reactor outlet temperature of 1100K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

  10. MXene Ti3C2: An Effective 2D Light-to-Heat Conversion Material

    KAUST Repository

    Li, Renyuan; Zhang, Lianbin; Shi, Le; Wang, Peng

    2017-01-01

    aqueous droplet light heating system along with a thorough mathematical procedure, which combined leads to a precise determination of internal light-to-heat conversion efficiency of a variety of nanomaterials. The internal light-to-heat conversion

  11. Experimental study of the thermal conductivity coefficients of Cesium and Mercury vapours and inert gases

    International Nuclear Information System (INIS)

    Zarkova, L.P.

    1976-01-01

    A general-purpose experimental setup is made to measure thermal conductivity coefficients lambda of inert gases and metal vapours in the range 1000-2500 K by means of the differential method. The setup can also be used to measure lambda of plasmas and reacting gases as well as the dependence of lambda on magnetic fields. A simple and reliable procedure to determine the filament temperature using values of the measured current and wire diameter is suggested. The influence of different factors such as the temperature jump at the boundary gas-filament, convective heat transfer, thermal expansion, excentricity and cold ends of filament on the measured values of the thermal conductivity is considered in details. A formula is deduced to calculate the temperature jump correction taking into account the dependence of the mean free path on the temperature. Expressions are also given to calculate the corrections for thermal expansion, eccentricity and cold ends of the filament. Thermal conductivity coefficients of inert gases are measured to check the method: Ne in the range 1100-2200 K, Ar in the range 1000-2200 K, Kr in the range 1300-2300 K and Xe in the range 1100-2200 K. The data for Ne and Xe in the range 1500 to 2200 K and for Kr at T=2000-2300 K are original. The thermal conductivity coefficient of monoatomic mercury vapour is measured in the range 1000-2300 K with 3% error. The thermal conductivity coefficient of monoatomic cesium vapour is also measured in the range 1000-1600 K with 4% error. (I.P.)

  12. Relationship between the Kubelka-Munk scattering and radiative transfer coefficients.

    Science.gov (United States)

    Thennadil, Suresh N

    2008-07-01

    The relationship between the Kubelka-Munk (K-M) and the transport scattering coefficient is obtained through a semi-empirical approach. This approach gives the same result as that given by Gate [Appl. Opt.13, 236 (1974)] when the incident beam is diffuse. This result and those given by Star et al. [Phys. Med. Biol.33, 437 (1988)] and Brinkworth [Appl. Opt.11, 1434 (1972)] are compared with the exact solution of the radiative transfer equation over a large range of optical properties. It is found that the latter expressions, which include an absorption component, do not give accurate results over the range considered. Using the semi-empirical approach, the relationship between the K-M and the transport scattering coefficient is derived for the case where the incident light is collimated. It is shown that although the K-M equation is derived based on diffuse incident light, it can also represent very well the reflectance from a slab of infinite thickness when the incident light is collimated. However, in this case the relationship between the coefficients has to include a function that is dependent on the anisotropy factor. Analysis indicates that the K-M transform achieves the objective of obtaining a measure that gives the ratio of absorption to scattering effects for both diffuse and collimated incident beams over a large range of optical properties.

  13. The Influence of Flexibility Coefficient on the Size of Internal Forces and Deformations in Circular Plates on Elastic Medium

    Directory of Open Access Journals (Sweden)

    Şandru Mirela

    2016-09-01

    Full Text Available This paper presents an analytical study which deals with the behavior of the circular plates in bending theory, considering the soil-structure interaction under Winkler's hypothesis. It was intended to illustrate the variation of internal forces and deformations according to the flexibility coefficient of plates considering three models: a fixed solid circular plate subjected to a uniformly distributed load, a fixed solid circular plate acted by a displacement applied on the exterior contour and a solid plate subjected to a temperature gradient. For this study the computation relations were written as a product between a dimensional and a non-dimensional factor, the last one indicating the variation of internal forces and deformations. For each type of action there are presented results obtained using the finite element method to illustrate the differences between this method and the analytical computation.

  14. Diffusion coefficient of hydrogen in niobium and tantalum

    International Nuclear Information System (INIS)

    Vargas, P.; Miranda, L.; Lagos, M.

    1988-08-01

    We show that the current data on hydrogen diffusion in Tantalum between 15K and 550K and in Niobium between 135K and 400K can be quantitatively explained by the small polaron theory. The experimental data can be understood assuming ground-state to ground-state tunneling between interstitial sites with tetrahedral symmetry plus an activated contribution due to tunneling between excited states having octahedral symmetry. The break of the diffusivity curve at T approx. = 250K follows naturally. It evidences the transition between the tetrahedral and octahedral hopping. For Ta the second break of the diffusivity curve at T approx. = 20K indicated the recovering of the ground-state hopping with tetrahedral symmetry. Below T approx. = 10K for Ta and T approx. = 7K for Nb the diffusion coefficient becomes independent of T. (author). 17 refs, 3 figs, 1 tab

  15. Study on the distribution coefficient during environmental impact evaluation in Chinese inland nuclear power plants

    International Nuclear Information System (INIS)

    Xu Haifeng; Shang Zhaorong; Chen Fangqiang

    2012-01-01

    Description the radionuclide distribution coefficient of the important factors in the river sediment systems, at home and abroad the main method of measuring the K d value and progress in China's inland nuclear power plant environmental impact assessment of workers to carry out the distribution coefficient K d value measurement ideas put forward recommendations. (authors)

  16. The design study of an ultra-high power EB/X-ray conversion facility

    Energy Technology Data Exchange (ETDEWEB)

    He, Zi-Feng, E-mail: hezifeng@sinap.ac.cn; Li, Deming; Huang, Jian-Ming; Yang, Yong-Jin; Zhu, Xi-Kai; Zhang, Yu-Tian

    2014-10-15

    Highlights: • We describe a 100 kW electron beam to X-rays conversion system. • We give an idea to improve the conversion efficiency and lifetime of the target. • We describe the design and thermal characteristics of the X-ray converter. - Abstract: X-ray conversion is a frequent need for irradiating the products that cannot be processed by electron beams, duo to their limited penetration capacity in materials, in radiation sterilization of disposable healthcare products and food irradiation. In this paper, we report the design of a conversion facility with a 5-MeV/120-kW electron accelerator, regarding the considerations on selection of the target materials and target structure, design of the electron beam transport line and approaches to improve the conversion efficiency and lifetime.

  17. Proceedings of the international meeting on research and test reactor core conversions from HEU to LEU fuels

    Energy Technology Data Exchange (ETDEWEB)

    Travelli, A [Argonne National Laboratory, Argonne, IL (United States)

    1983-09-01

    Conversion of research and test reactor cores from the use of high enrichment uranium to the use of low enrichment uranium depends on the cooperation of many research organizations, reactor operators, and government agencies. At a technical level, it involves almost all aspects of the fuel cycle, including fuel development, testing, shipping and reprocessing; experiment performance; economics; and safety and licensing aspects. The reactors involved and the conversion activities are distributed among approximately 25 countries, making this a subject which is best dealt with on an international basis. To foster direct communication in this area, the Reduced Enrichment Research and Test Reactor (RERTR) Program, at the Argonne National Laboratory, sponsored this meeting as the fifth of a series which began in 1978. The previous meetings were held at Argonne (International Meeting of Research Reactor Fuel Designers, Developers, and Fabricators, Argonne National Laboratory, Argonne, U.S.A., November 910, 1978), at Saclay (IAEA Consultants' Meeting on Research Reactor Core Conversions from HEU to LEU, Centre d'etudes Nucleaires de Saclay, Saclay, France, December 12-14, 1979), at Argonne (International Meeting on Development, Fabrication and Application of Reduced Enrichment Fuels for Research and Test Reactors, Argonne National Laboratory, Argonne, U.S.A., November 12-14, 1980) and at Juelich (Seminar on Research Reactor Operation and Use, Juelich Nuclear Research Center, Juelich, F.R.G., September 48, 1981). Proceedings from the two most recent previous meetings were published as ANL/RERTR/TM-3 (CONF-801144) and IAEA-SR-77. The spirit of this meeting differs slightly from that of the previous meetings. The advances which have been made and the growing maturity of the effort have caused a gradual shift of emphasis away from those topics which dominated the floor during the first meetings, such as fuel and methods development, and towards topics which concern more

  18. Proceedings of the international meeting on research and test reactor core conversions from HEU to LEU fuels

    International Nuclear Information System (INIS)

    Travelli, A.

    1983-09-01

    Conversion of research and test reactor cores from the use of high enrichment uranium to the use of low enrichment uranium depends on the cooperation of many research organizations, reactor operators, and government agencies. At a technical level, it involves almost all aspects of the fuel cycle, including fuel development, testing, shipping and reprocessing; experiment performance; economics; and safety and licensing aspects. The reactors involved and the conversion activities are distributed among approximately 25 countries, making this a subject which is best dealt with on an international basis. To foster direct communication in this area, the Reduced Enrichment Research and Test Reactor (RERTR) Program, at the Argonne National Laboratory, sponsored this meeting as the fifth of a series which began in 1978. The previous meetings were held at Argonne (International Meeting of Research Reactor Fuel Designers, Developers, and Fabricators, Argonne National Laboratory, Argonne, U.S.A., November 910, 1978), at Saclay (IAEA Consultants' Meeting on Research Reactor Core Conversions from HEU to LEU, Centre d'etudes Nucleaires de Saclay, Saclay, France, December 12-14, 1979), at Argonne (International Meeting on Development, Fabrication and Application of Reduced Enrichment Fuels for Research and Test Reactors, Argonne National Laboratory, Argonne, U.S.A., November 12-14, 1980) and at Juelich (Seminar on Research Reactor Operation and Use, Juelich Nuclear Research Center, Juelich, F.R.G., September 48, 1981). Proceedings from the two most recent previous meetings were published as ANL/RERTR/TM-3 (CONF-801144) and IAEA-SR-77. The spirit of this meeting differs slightly from that of the previous meetings. The advances which have been made and the growing maturity of the effort have caused a gradual shift of emphasis away from those topics which dominated the floor during the first meetings, such as fuel and methods development, and towards topics which concern more

  19. Activity coefficients at infinite dilution of organic solutes in the ionic liquid trihexyltetradecylphosphonium bis (trifluoromethylsulfonyl) imide using gas–liquid chromatography at T = (313.15, 333.15, 353.15 and 373.15) K

    International Nuclear Information System (INIS)

    Tumba, Kaniki; Letcher, Trevor M.; Naidoo, Paramespri; Ramjugernath, Deresh

    2013-01-01

    Highlights: • Activity coefficients at infinite dilution measured in the ionic liquid [3C 6 C 14 P][BTI]. • 22 solutes investigated at T = (313.15, 333.15, 353.15, 373.15) K using glc. • Selectivities and capacities for selected separations compared to other IL’s and solvents. -- Abstract: Activity coefficients at infinite dilution for organic solutes, which include n-alkanes, alk-1-enes, alk-1-ynes, cycloalkanes, alkylbenzenes, alcohols and ketones, in the ionic liquid trihexyltetradecylphosphonium bis (trifluoromethylsulfonyl) imide were measured by gas–liquid chromatography using the latter as the stationary phase. This ionic liquid had previously been studied and reported in literature; however due to significant discrepancies in the reported infinite activity coefficient values, there was justification for further study and reporting. The temperature range investigated in this study is significantly wider and at higher temperatures than presented previously in the literature. From the experimental infinite dilution activity coefficient data at the four different temperatures T = (313.15, 333.15, 353.15 and 373.15) K, partial molar excess enthalpies at infinite dilution were calculated. Values of the selectivity for hexane/benzene and methanol/benzene separations were determined from experimental values of the activity coefficients at infinite dilution and these results were compared to literature values for other ionic liquids, as well as for industrial solvents. The capacities were also determined as it gives an indication of the solvent extraction behavior of the ionic liquid

  20. Watershed wash-off of atmospherically deposited radionuclides: a review of normalized entrainment coefficients

    International Nuclear Information System (INIS)

    Garcia-Sanchez, L.; Konoplev, A.V.

    2009-01-01

    Radionuclide wash-off is the transport of activity by flowing water over the soil surface (runoff). To complete existing reviews on long-term removal rates, this paper focuses on short-term wash-off fluxes, quantified in the literature by soil-runoff transfer factors called normalized liquid and solid entrainment coefficients (noted K l *, K s *). Compiled data concerned essentially 137 Cs and 90 Sr wash-off measured under simulated rainfalls on small experimental plots after Chernobyl fallout in the exclusion zone. K l * and K s * values span approximately one order of magnitude. Their validity is limited to a season, and their representativeness is limited by restricted studied situations, notably dominant unsoluble forms in fallout, light soils and intense rainfalls. Formulas based on a simplified representation of the soil-runoff system were proposed to generalize the existing values for other conditions. However, their implementation requires a more systematic compilation of the available information, including decisive influence factors such as the fraction of exchangeable form, distribution coefficient, suspended matter enrichment ratio. Entrainment coefficients K l * and K s * were mathematically related to the transfer function approach. The proposed relationships proved their complementarity in terms of time support and captured fluctuations. Both approaches should be used in assessments to estimate average fluxes and their variability.

  1. Temperature dependence of diffusion coefficients of trivalent uranium ions in chloride and chloride-fluoride melts

    International Nuclear Information System (INIS)

    Komarov, V.E.; Borodina, N.P.

    1981-01-01

    Diffusion coefficients of U 3+ ions are measured by chronopotentiometric method in chloride 3LiCl-2KCl and in mixed chloride fluoride 3LiCl(LiF)-2KCl melts in the temperature range 633-1235 K. It is shown It is shown that experimental values of diffusion-coefficients are approximated in a direct line in lg D-1/T coordinate in chloride melt in the whole temperature range and in chloride-fluoride melt in the range of 644-1040 K. Experimental values of diffusion coefficients diviate from Arrhenius equation in the direction of large values in chloride-fluoride melt at further increase of temperature up to 1235 K. Possible causes of such a diviation are considered [ru

  2. Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Jung Yu, Dae [School of Space Research, Kyung Hee University, Yongin 446-701 (Korea, Republic of); Kim, Kihong [Department of Energy Systems Research, Ajou University, Suwon 443-749 (Korea, Republic of)

    2013-12-15

    We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region.

  3. Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

    International Nuclear Information System (INIS)

    Jung Yu, Dae; Kim, Kihong

    2013-01-01

    We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region

  4. Neutron scattering and proton spin conversion in solid CH4

    International Nuclear Information System (INIS)

    Lushington, K.J.; Morrison, J.A.

    1977-01-01

    The total neutron cross section of pure and O 2 -doped condensed CH 4 has been measured in the temperature range 0.75< T<100 K. The neutron wave length was sufficiently long (4.7 A) so that changes in cross section could be directly related to changes in γI(I + 1)μ, the mean squared proton nuclear angular momentum per molecule, to a sensitivity of about 1%. The temperature dependences of γI(I + 1)μ for the pure and doped specimens differ considerably in solid phase II(T<20.4 K). For the former specimen, the change in cross section is consistent with conversion occurring between the nuclear spin symmetry species on the orientationally disordered sublattices only. The addition of oxygen enhances the rate of conversion such that the value of γI(I + 1)μ corresponds to conversion on both the disordered and ordered sublattices. The characteristic lifetimes of the catalyzed and uncatalyzed conversion processes have been estimated. (author)

  5. Utility of K-Means clustering algorithm in differentiating apparent diffusion coefficient values between benign and malignant neck pathologies

    Science.gov (United States)

    Srinivasan, A.; Galbán, C.J.; Johnson, T.D.; Chenevert, T.L.; Ross, B.D.; Mukherji, S.K.

    2014-01-01

    Purpose The objective of our study was to analyze the differences between apparent diffusion coefficient (ADC) partitions (created using the K-Means algorithm) between benign and malignant neck lesions and evaluate its benefit in distinguishing these entities. Material and methods MRI studies of 10 benign and 10 malignant proven neck pathologies were post-processed on a PC using in-house software developed in MATLAB (The MathWorks, Inc., Natick, MA). Lesions were manually contoured by two neuroradiologists with the ADC values within each lesion clustered into two (low ADC-ADCL, high ADC-ADCH) and three partitions (ADCL, intermediate ADC-ADCI, ADCH) using the K-Means clustering algorithm. An unpaired two-tailed Student’s t-test was performed for all metrics to determine statistical differences in the means between the benign and malignant pathologies. Results Statistically significant difference between the mean ADCL clusters in benign and malignant pathologies was seen in the 3 cluster models of both readers (p=0.03, 0.022 respectively) and the 2 cluster model of reader 2 (p=0.04) with the other metrics (ADCH, ADCI, whole lesion mean ADC) not revealing any significant differences. Receiver operating characteristics curves demonstrated the quantitative difference in mean ADCH and ADCL in both the 2 and 3 cluster models to be predictive of malignancy (2 clusters: p=0.008, area under curve=0.850, 3 clusters: p=0.01, area under curve=0.825). Conclusion The K-Means clustering algorithm that generates partitions of large datasets may provide a better characterization of neck pathologies and may be of additional benefit in distinguishing benign and malignant neck pathologies compared to whole lesion mean ADC alone. PMID:20007723

  6. Review of direct energy conversion for fusion reactors

    International Nuclear Information System (INIS)

    Barr, W.L.; Moir, R.W.

    1976-01-01

    The direct conversion to electrical energy of the energy carried by the leakage plasma from a fusion reactor and by the ions that are not converted to neutrals in a neutral-beam injector is discussed. The conversion process is electrostatic deceleration and direct particle collection as distinct from plasma expansion against a time-varying magnetic field or conversion in an EXB duct (both MHD). Relatively simple 1-stage plasma direct converters are discussed which can have efficiencies of about 50 percent. More complex and costly (measured in $/kW) 2-, 3-, 4-, and 22-stage concepts have been tested at efficiencies approaching 90 percent. Beam direct converters have been tested at 15 keV and 2 kW of power at 70 +- 2 percent efficiency, and a test of a 120-keV, 1-MW version is being prepared. Designs for a 120-keV, 4-MW unit are presented. The beam direct converter, besides saving on power supplies and on beam dumps, should raise the efficiency of creating a neutral beam from 40 percent without direct conversion to 70 percent with direct conversion for a 120-keV deuterium beam. The technological limits determining power handling and lifetime such as space-charge effects, heat removal, electrode material, sputtering, blistering, voltage holding, and insulation design, are discussed. The application of plasma direct converters to toroidal plasma confinement concepts is also discussed

  7. OCTANOL/WATER PARTITION COEFFICIENTS AND WATER SOLUBILITIES OF PHTHALATE ESTERS

    Science.gov (United States)

    Measurements of the octanol/water partition coefficients (K-ow) and water solubilities of di-n-octyl phthalate (DnOP) and di-n-decyl phthalate (DnDP) by the slow-stirring method are reported. The water solubility was also measured for di-n-hexyl phthalate (DnHP). The log K-ow val...

  8. The spatiotemporal dynamic analysis of the implied market information and characteristics of the correlation coefficient matrix of the international crude oil price returns

    International Nuclear Information System (INIS)

    Tian, Lixin; Ding, Zhenqi; Zhen, Zaili; Wang, Minggang

    2016-01-01

    The international crude oil market plays a crucial role in economies, and the studies of the correlation, risk and synchronization of the international crude oil market have important implications for the security and stability of the country, avoidance of business risk and people's daily lives. We investigate the information and characteristics of the international crude oil market (1999-2015) based on the random matrix theory (RMT). Firstly, we identify richer information in the largest eigenvalues deviating from RMT predictions for the international crude oil market; the international crude oil market can be roughly divided into ten different periods by the methods of eigenvectors and characteristic combination, and the implied market information of the correlation coefficient matrix is advanced. Secondly, we study the characteristics of the international crude oil market by the methods of system risk entropy, dynamic synchronous ratio, dynamic non-synchronous ratio and dynamic clustering algorithm. The results show that the international crude oil market is full of risk. The synchronization of the international crude oil market is very strong, and WTI and Brent occupy a very important position in the international crude oil market. (orig.)

  9. The spatiotemporal dynamic analysis of the implied market information and characteristics of the correlation coefficient matrix of the international crude oil price returns

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Lixin [Jiangsu University, Energy Development and Environmental Protection Strategy Research Center, Zhenjiang, Jiangsu (China); Nanjing Normal University, School of Mathematical Sciences, Nanjing, Jiangsu (China); Ding, Zhenqi; Zhen, Zaili [Jiangsu University, Energy Development and Environmental Protection Strategy Research Center, Zhenjiang, Jiangsu (China); Wang, Minggang [Nanjing Normal University, School of Mathematical Sciences, Nanjing, Jiangsu (China)

    2016-08-15

    The international crude oil market plays a crucial role in economies, and the studies of the correlation, risk and synchronization of the international crude oil market have important implications for the security and stability of the country, avoidance of business risk and people's daily lives. We investigate the information and characteristics of the international crude oil market (1999-2015) based on the random matrix theory (RMT). Firstly, we identify richer information in the largest eigenvalues deviating from RMT predictions for the international crude oil market; the international crude oil market can be roughly divided into ten different periods by the methods of eigenvectors and characteristic combination, and the implied market information of the correlation coefficient matrix is advanced. Secondly, we study the characteristics of the international crude oil market by the methods of system risk entropy, dynamic synchronous ratio, dynamic non-synchronous ratio and dynamic clustering algorithm. The results show that the international crude oil market is full of risk. The synchronization of the international crude oil market is very strong, and WTI and Brent occupy a very important position in the international crude oil market. (orig.)

  10. Full-spectrum volumetric solar thermal conversion via photonic nanofluids.

    Science.gov (United States)

    Liu, Xianglei; Xuan, Yimin

    2017-10-12

    Volumetric solar thermal conversion is an emerging technique for a plethora of applications such as solar thermal power generation, desalination, and solar water splitting. However, achieving broadband solar thermal absorption via dilute nanofluids is still a daunting challenge. In this work, full-spectrum volumetric solar thermal conversion is demonstrated over a thin layer of the proposed 'photonic nanofluids'. The underlying mechanism is found to be the photonic superposition of core resonances, shell plasmons, and core-shell resonances at different wavelengths, whose coexistence is enabled by the broken symmetry of specially designed composite nanoparticles, i.e., Janus nanoparticles. The solar thermal conversion efficiency can be improved by 10.8% compared with core-shell nanofluids. The extinction coefficient of Janus dimers with various configurations is also investigated to unveil the effects of particle couplings. This work provides the possibility to achieve full-spectrum volumetric solar thermal conversion, and may have potential applications in efficient solar energy harvesting and utilization.

  11. Assessment of the Maximal Split-Half Coefficient to Estimate Reliability

    Science.gov (United States)

    Thompson, Barry L.; Green, Samuel B.; Yang, Yanyun

    2010-01-01

    The maximal split-half coefficient is computed by calculating all possible split-half reliability estimates for a scale and then choosing the maximal value as the reliability estimate. Osburn compared the maximal split-half coefficient with 10 other internal consistency estimates of reliability and concluded that it yielded the most consistently…

  12. Software development for estimating the conversion factor (k-factor) at suitable scan areas, relating the dose length product to the effective dose

    International Nuclear Information System (INIS)

    Kobayashi, Masanao; Asada, Yasuki; Suzuki, Syouichi; Kato, Ryouichi; Matsubara, Kosuke; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi

    2017-01-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. (authors)

  13. On the Energy Conversion Efficiency of Piezoelectric Vibration Energy Harvesting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Eun [Catholic University of Daegu, Kyungsan (Korea, Republic of)

    2015-05-15

    To properly design and assess a piezoelectric vibration energy harvester, it is necessary to consider the application of an efficiency measure of energy conversion. The energy conversion efficiency is defined in this work as the ratio of the electrical output power to the mechanical input power for a piezoelectric vibration energy harvester with an impedance-matched load resistor. While previous research works employed the electrical output power for approximate impedance-matched load resistance, this work derives an efficiency measure considering optimally matched resistance. The modified efficiency measure is validated by comparing it with finite element analysis results for piezoelectric vibration energy harvesters with three different values of the electro-mechanical coupling coefficient. New findings on the characteristics of energy conversion and conversion efficiency are also provided for the two different impedance matching methods.

  14. [Evaluation of the Peusner's coefficients matrix for polymeric membrane and ternary non-electrolyte solutions].

    Science.gov (United States)

    Jasik-Slęzak, Jolanta; Slęzak-Prochazka, Izabella; Slęzak, Andrzej

    2014-01-01

    A system of network forms of Kedem-Katchalsky (K-K) equations for ternary non-electrolyte solutions is made of eight matrix equations containing Peusner's coefficients R(ij), L(ij), H(ij), W(ij), K(ij), N(ij), S(ij) or P(ij) (i, j ∈ {1, 2, 3}). The equations are the result of symmetric or hybrid transformation of the classic form of K-K equations by the use of methods of Peusner's network thermodynamics (PNT). Calculating concentration dependences of the determinant of Peusner's coefficients matrixes R(ij), L(ij), H(ij), W(ij), S(ij), N(ij), K(ij) and P(ij) (i, j ∈ {1, 2, 3}). The material used in the experiment was a hemodialysis Nephrophan membrane with specified transport properties (L(p), σ, Ω) in aqueous glucose and ethanol solution. The method involved equations for determinants of the matrixes coefficients R(ij), L(ij), H(ij), W(ij), S(ij), N(ij), K(ij) or P(ij) (i, j ∈ {1, 2, 3}). The objective of calculations were dependences of determinants of Peusner's coeffcients matrixes R(ij), L(ij), H(ij), W(ij), S(ij), N(ij), K(ij) or P(ij) (i, j ∈ {1, 2, 3}) within the conditions of solution homogeneity upon an average concentration of one component of solution in the membrane (C1) with a determined value of the second component (C2). The method of calculating the determinants of Peusner's coeffcients matrixes R(ij), L(ij), H(ij), W(ij), S(ij), N(ij), K(ij) or P(ij) (i, j ∈ {1, 2, 3}) is a new tool that may be applicable in studies on membrane transport. Calculations showed that the coefficients are sensitive to concentration and composition of solutions separated by a polymeric membrane.

  15. Laboratory Study of the OH + Permethylsiloxane (L2, L3, D3, and D4) Reaction Rate Coefficients Between 240 and 370 K

    Science.gov (United States)

    Burkholder, J. B.; Bernard, F.; Papadimitriou, V. C.

    2016-12-01

    The atmospheric chemistry of organosiloxanes has recently been implicated in the formation of new particles as well as regional and indoor air quality. Methylsiloxanes with Sitextiles, health care and household products and in industrial applications as solvents and lubricants. They are released into the atmosphere during manufacturing, use, and disposal and have been observed in the atmosphere in ppb levels in certain locations. However, the fundamental chemical properties of this class of compounds, particularly their reactivity with the OH radical, are presently not fully characterized. In this work, the temperature dependence of the rate coefficients for the OH radical reaction with the simplest linear (L2 and L3) and cyclic (D3 and D4) siloxanes were measured: OH + (CH3)3SiOSi(CH3)3 = Products L2OH + [(CH3)3SiO]2Si(CH3)2 = Products L3OH + [-Si(CH3)2O-]3 = Products D3OH + [-Si(CH3)2O-]4 = Products D4OH rate coefficients were measured under pseudo-first conditions in OH over the temperature range 240-370 K using a pulsed laser photolysis-laser induced fluorescence (PLP-LIF) technique and at 296 K using a relative rate method. The present results are compared with available literature data where possible and discrepancies are discussed. The results from this work will be discussed in terms of the atmospheric lifetimes of these methylsiloxanes and the reactivity trends for this class of compound.

  16. Review on cation exchange selectivity coefficients for MX-80 bentonite

    International Nuclear Information System (INIS)

    Domenech, C.; Arcos, D.; Duro, L.; Sellin, P.

    2005-01-01

    Full text of publication follows: Bentonite is considered as engineered barrier in the near field of a nuclear waste repository due to its low permeability, what impedes groundwater flow to the nuclear waste, and its high retention capacity (sorption) of radionuclides in the eventuality of groundwater intrusion. One of the main retention processes occurring at the bentonite surface is ion exchange. This process may exert a strong control on the mobility of major pore water cations. Changes in major cation concentration, especially calcium, can affect the dissolution-precipitation of calcite, which in turn controls one of the key parameters in the system: pH. The cation exchange process is usually described according to the Gaines-Thomas convention: Ca 2+ + 2 NaX = CaX 2 + 2 Na + , K Ca = (N Ca x a 2 Na + )/(N 2 Na x a Ca 2+ ) where K Ca is the selectivity coefficient for the Ca by Na exchange, ai is the activity of cation 'i' in solution and NJ the equivalent fractional occupancy of cation 'J' in bentonite. Parameters such as solid to liquid (S:L) ratio and dry density of the solid have an important influence on the value of selectivity coefficients (K ex ). Although in most geochemical modelling works, K ex values are directly taken from experiments conducted at low S:L ratios and low dry densities, the expected conditions in a deep geological nuclear waste repository are higher S:L and higher bentonite density (1.6 g.cm -3 in the SKB design to obtain a fully water saturated density of around 2.0 g.cm -3 ). Experiments focused at obtaining selectivity coefficients under the conditions of interest face the difficulty of achieving a proper extraction and analyses of pore water without disturbing the system by the sampling method itself. In this work we have conducted a complete analyses of published data on MX-80 bentonite cationic exchange in order to assess the effect of the S:L ratio and dry density on the value of the selectivity coefficients determined so far

  17. Calculation of conversion coefficients for effective dose by using voxel phantoms with defined genus for radiodiagnostic common examinations

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Vieira, J.W.; Loureiro, E.C.M.; Hoff, G.

    2004-01-01

    Patient exposure from radiological examinations is usually quantified in terms of average absorbed dose or equivalent dose to certain radiosensitive organs of the human body. As these quantities cannot be measured in vivo, it is common practice to use physical or computational exposure models, which simulate the exposure to the patient in order to determine not only the quantities of interest (absorbed or equivalent dose), but also at the same time measurable quantities for the exposure conditions given. The ratio between a quantity of interest and a measurable quantity is called a conversion coefficient (CC), which is a function of the source and field parameters (tube voltage, filtration, field size, field position, focus-to-skin distance, etc.), the anatomical properties of the phantom, the elemental composition of relevant body tissues, and the radiation transport method applied. As the effective dose represents a sum over 23 risk-weighted organ and tissue equivalent doses, its determination practically implies the measurement or calculation of a complete distribution of equivalent doses throughout the human body. This task can be resolved most efficiently by means of computational exposure models, which consist of a virtual representation of the human body, also called phantom, connected to a Monte Carlo radiation transport computer code. The recently introduced MAX (Male Adult voXel) and FAXht (Female Adult voXel) head+trunk phantoms have been chosen for this task. With respect to their anatomical properties these phantoms correspond fairly well to the data recommended by the ICRP for the Reference Adult Male and Female. (author)

  18. k{sub 0}-INAA application at IPEN Neutron Activation Laboratory by using the k{sub 0}-IAEA program: biological sample analysis; Aplicacao do metodo k{sub 0}-INAA no Laboratorio de Analise por Ativacao com Neutrons do IPEN utilizando o programa k{sub 0}-IAEA: analise de amostras biologicas

    Energy Technology Data Exchange (ETDEWEB)

    Puerta, Daniel Correa

    2013-07-01

    The results obtained in the application of the k{sub 0}-standardization method at LAN-IPEN for biological matrices analysis, by using the k{sub 0}-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and a of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with {sup 197}Au-{sup 96}Zr-{sup 94}Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The U-score test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k{sub 0}-INAA method at LAN-IPEN for biological sample analysis. (author)

  19. Topological K-Kolmogorov groups

    International Nuclear Information System (INIS)

    Abd El-Sattar, A. Dabbour.

    1987-07-01

    The idea of the K-groups was used to define K-Kolmogorov homology and cohomology (over pairs of coefficient groups) which are descriptions of certain modifications of the Kolmogorov groups. The present work is devoted to the study of the topological properties of the K-Kolmogorov groups which lie at the root of the group duality based essentially upon Pontrjagin's concept of group multiplication. 14 refs

  20. Calculation of self-diffusion coefficients in iron

    Directory of Open Access Journals (Sweden)

    Baohua Zhang

    2014-01-01

    Full Text Available On the basis of available P-V-T equation of state of iron, the temperature and pressure dependence of self-diffusion coefficients in iron polymorphs (α, δ, γ and ɛ phases have been successfully reproduced in terms of the bulk elastic and expansivity data by means of a thermodynamical model that interconnects point defects parameters with bulk properties. The calculated diffusion parameters, such as self-diffusion coefficient, activation energy and activation volume over a broad temperature range (500-2500 K and pressure range (0-100 GPa, compare favorably well with experimental or theoretical ones when the uncertainties are considered.