WorldWideScience

Sample records for jumbo 5-t cbr-proof

  1. The Inglorious Death of Jumbo

    Energy Technology Data Exchange (ETDEWEB)

    Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-28

    In the summer of 1944, J. Robert Oppenheimer and Los Alamos faced a crisis. An isotopic impurity in Plutonium rendered the metal unusable in a gun-assembled atomic bomb (i.e., Little Boy). Making this situation worse was a shortage of Uranium. The combination of these two problems threatened the entire wartime project. The answer to this dilemma, in part, was to develop a novel assembly method for Plutonium using the supersonic shock waves created by several tons of high explosives to compress a ball of Plutonium into a supercritical state. Since this method, implosion, was not much more than a theoretical construct, the Trinity test was devised to proof test the process. Given the speculative nature of implosion, Trinity was a gamble of sorts. If the test failed (i.e., little or no nuclear yield), the blast of the high explosives would scatter the scarce and expensive Plutonium over the surrounding desert. Since the probability of failure remained high into the early summer of 1945, some method of containing a failed nuclear explosion was needed. Jumbo was the answer.

  2. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  3. Jumbo Space Environment Simulation and Spacecraft Charging Chamber Characterization

    Science.gov (United States)

    2015-04-09

    probes for Jumbo. Both probes are produced by Trek Inc. Trek probe model 370 is capable of -3 to 3kV and has an extremely fast, 50µs/kV response to...changing surface potentials. Trek probe 341B is capable of -20 to 20kV with a 200 µs/kV response time. During our charging experiments the probe sits...unlimited. 12 REFERENCES [1] R. D. Leach and M. B. Alexander, "Failures and anomalies attributed to spacecraft charging," NASA RP-1375, Marshall Space

  4. Fishery biology of jumbo flying squid Dosidicus gigas off Costa Rica Dome

    Science.gov (United States)

    Chen, Xinjun; Li, Jianghua; Liu, Bilin; Li, Gang; Lu, Huajie

    2014-06-01

    The jumbo flying squid ( Dosidicus gigas) population was surveyed with the help of Chinese squid jigging vessels off the Costa Rica Dome (4°-11°N, 90°-100°W) in 2009 and 2010. The daily catch of D. gigas in the two survey cruises ranged from 0 to 5.5 t and was mostly obtained from the areas bounded by 6°-9°N and 91°-94°W and by 6°30'-7°30'N and 96°-97°W. The sea surface temperature in the areas yielding the most catch ranged from 27.5 to 29°C. The sex ratio of the total catch was 3.75:1 (female: male). The mantle length of the squid ranged from 211 to 355 mm (male) and from 204 to 429 mm (female) with an average of 297.9 and 306.7 mm, respectively. In the relationship of the mantle length (mm) and body weight (g) of the squid, there was no significant difference between sexes. The female and male were at a similar maturity, and most individuals are maturing or have matured with a few females being spent. The size (mantle length) and age at the first sexual maturity were 297 mm and 195 d in females, and less than 211 mm and 130 d in males, respectively. Most of the sampled stomachs (70.6%) had no food remains. The major preys of the squids were fish, cephalopods and crustaceans, with the most abundant Myctophum orientale and D. gigas. The preys in more than 65% of the non-empty sampled stomachs evidenced the cannibalism of D. gigas. The results improved current understanding of the fishery biology of D. gigas off the Costa Rica Dome, which may facilitate the assessment and management of relative fishery resources.

  5. Trophic relationships between the jumbo squid (Dosidicus gigas and the lightfish (Vinciguerria lucetia in the Humboldt Current System off Peru

    Directory of Open Access Journals (Sweden)

    Rigoberto Rosas-Luis

    2011-04-01

    Full Text Available Acoustic surveys for assessing the biomass and distribution of the jumbo squid (Dosidicus gigas and the lightfish (Vinciguerria lucetia were carried out in the Humboldt Current System of Peru in 2007 and 2008. At the same time, 937 jumbo squid were caught and their stomach contents analyzed. The diet of the jumbo squid was dominated by mesopelagic fish. The first component of their fish diet was V. lucetia and the second component was the myctophid fish Diogenichthys laternatus. Acoustic biomass estimates of these species show that V. lucetia is an important component in aggregative structures in the Humboldt Current System of Peru and its distribution and movements are closely related to the migratory movements of the jumbo squid. The trophic relationship observed between D. gigas and V. lucetia promotes an increase in jumbo squid biomass and, has a positive trophic effect on the ocean ecosystem.

  6. Size increment of jumbo flying squid Dosidicus gigas mature females in Peruvian waters, 1989-2004

    Science.gov (United States)

    Argüelles, Juan; Tafur, Ricardo; Taipe, Anatolio; Villegas, Piero; Keyl, Friedeman; Dominguez, Noel; Salazar, Martín

    2008-10-01

    Changes in population structure of the jumbo flying squid Dosidicus gigas in Peruvian waters were studied based on size-at-maturity from 1989 to 2004. From 1989 to 1999, mature squid belonging to the medium-sized group prevailed, but from 2001 on, mature squids were larger. This change is not related to the changes in sea surface temperature and we hypothesized that it was caused by the population increase of mesopelagic fishes as prey.

  7. P - aminobenzoic - 3,5 - T acid

    International Nuclear Information System (INIS)

    Mihaila, V.; Corol, Delia

    1999-01-01

    The p-aminobenzoic acid (PABA) is used in the treatment of rheumatoid arthritis and dermatological diseases. The tritium labelling of PABA leads to the elucidation of essential biomedical aspects concerning the collagen behavior. The process of tritium introduction into the PABA molecule consists of two steps: 1. Bromination of PABA with elemental bromine in 3 and 5 positions; 2. Replacement of bromine with tritium by a substitution catalytic reaction.. PABA - 3,5 - T is purified by thin layer preparative chromatography and is characterized radiochemically by radioactivity measurements carried out by liquid scintillators. The chemical concentration is determined by UV spectrophotometry. The quenching is estimated using a calibration curve of the pure product. The specific activities (about 50-60 Ci/mM) allow very sensitive biomedical studies to be performed. (authors)

  8. 26 CFR 1.181-5T - Examples (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Examples (temporary). 1.181-5T Section 1.181-5T...) INCOME TAXES Itemized Deductions for Individuals and Corporations (continued) § 1.181-5T Examples (temporary). The following examples illustrate the application of §§ 1.181-1T through 1.181-4T: Example 1. X...

  9. Identifying X-consumers using causal recipes: "whales" and "jumbo shrimps" casino gamblers.

    Science.gov (United States)

    Woodside, Arch G; Zhang, Mann

    2012-03-01

    X-consumers are the extremely frequent (top 2-3%) users who typically consume 25% of a product category. This article shows how to use fuzzy-set qualitative comparative analysis (QCA) to provide "causal recipes" sufficient for profiling X-consumers accurately. The study extends Dik Twedt's "heavy-half" product users for building theory and strategies to nurture or control X-behavior. The study here applies QCA to offer configurations that are sufficient in identifying "whales" and "jumbo shrimps" among X-casino gamblers. The findings support the principle that not all X-consumers are alike. The theory and method are applicable for identifying the degree of consistency and coverage of alternative X-consumers among users of all product-service category and brands.

  10. Hypoxia tolerance and antioxidant defense system of juvenile jumbo squids in oxygen minimum zones

    Science.gov (United States)

    Trübenbach, Katja; Teixeira, Tatiana; Diniz, Mário; Rosa, Rui

    2013-10-01

    Jumbo squid (Dosidicus gigas) is a large oceanic squid endemic off the Eastern Tropical Pacific that undertakes diel vertical migrations into mesopelagic oxygen minimum zones. One of the expected physiological effects of such migration is the generation of reactive oxygen species (ROS) at the surface, promoted by the transition between hypoxia and reoxygenation states. The aim of this study was to investigate the energy expenditure rates and the antioxidant stress strategies of juvenile D. gigas under normoxia and hypoxia, namely by quantifying oxygen consumption rates, antioxidant enzyme activities [including superoxide dismutase (SOD), catalase (CAT) and glutathione-S-transferase (GST)], heat shock protein expression (Hsp70/Hsc70), and lipid peroxidation [malondialdehyde (MDA) levels]. A high significant decrease (68%) in squid's metabolic rates was observed during hypoxia (p0.05), with the latter indicating no enhancement of lipid peroxidation (i.e. cellular damage) at the warmer and normoxic surface waters. The understanding of such physiological strategies that are linked to oxygen deprivation and reoxygenation phases may provide valuable information about how this species is quickly responding to the impacts of environmental stressors coupled with global climate change.

  11. 26 CFR 1.897-5T - Corporate distributions (temporary).

    Science.gov (United States)

    2010-04-01

    ... also subject to the tax avoidance rules of § 1.897-6T(c). (b) Distributions by domestic corporations—(1... TAX (CONTINUED) INCOME TAXES Miscellaneous Provisions § 1.897-5T Corporate distributions (temporary...) Any U.S. tax paid by or on behalf of the distributee with respect to the distribution. (2...

  12. Important innovations in conventional drivage technology by a new generation of drilling jumbos; Massgebende Innovationen in der konventionellen Vortriebstechnologie durch eine neue Bohrwagengeneration

    Energy Technology Data Exchange (ETDEWEB)

    Wennmohs, Karl-Heinz [Atlas Copco MCT GmbH, Essen (Germany). Global Strategic Customers

    2009-01-29

    Important innovations in the development of the new generation of drilling jumbos led to an increase in the performance of conventional drivage technology, which had previously not been considered possible. An important factor in addition to the high drilling rate is the greater precision of the kinematics. This permits important cost savings on concrete and re-profiling. At the same time customer requirements such as the pre-drilling technology, recording of drilling parameters, profile monitoring and communication engineering were implemented in this new generation of drilling jumbos. (orig.)

  13. The biology and ecology of the jumbo squid Dosidicus gigas (Cephalopoda in Chilean waters: a review

    Directory of Open Access Journals (Sweden)

    Christian M Ibáñez

    2015-07-01

    Full Text Available ABSTRACT. The jumbo squid Dosidicus gigas is the most abundant cephalopod species in the southeastern Pacific Ocean, which supports the biggest cephalopod fishery in the world. Due to its growing economic importance, the population growth and distributional expansion of this squid is being increasingly studied. Nevertheless, some basic features of the biology of D. gigas are still unknown or have been poorly investigated. In this review we summarize the known information regarding the biology and ecology of this species in the southeastern Pacific Ocean; we focus on the Chilean region in order to propose hypotheses and research lines for a better understanding the life history of this organism. Available data on the size structure, reproduction and genetics of D. gigas allows us to propose hypotheses related to the squid's life history traits. Based on the current literature and publications of colleagues, we propose two hypotheses regarding the effect of spatial variation on the life history of D. gigas. Hypothesis 1: Squids mature at large sizes and spawn in oceanic waters with warm temperatures where paralarvae and juveniles develop. Immature squids migrate near shore to feed, grow and mature, and then return to the offshore sites to spawn. Hypothesis 2: Alternatively, juvenile D. gigas in the oceanic zone do not migrate to coastal waters and mature at small sizes compared to individuals living near the coast that mature at larger size and migrate to oceanic waters to spawn. We provide background information about the feeding behavior and parasitism of this species, suggesting that D. gigas is an important trophic link in the southeastern Pacific marine ecosystem. However, more studies on the feeding habits, reproduction and parasite load are needed not only to test hypotheses proposed in this study, but also to advance the overall knowledge of this species.

  14. A Comparative Study of Spatially Clustered Distribution of Jumbo Flying Squid (Dosidicus gigas) Offshore Peru

    Institute of Scientific and Technical Information of China (English)

    FENG Yongjiu; CUI Li; CHEN Xinjun; LIU Yu

    2017-01-01

    We examined spatially clustered distribution of jumbo flying squid (Dosidicus gigas) in the offshore waters of Peru bounded by 78°-86°W and 8°-20°S under 0.5°×0.5° fishing grid.The study is based on the catch-per-unit-effort (CPUE) and fishing effort from Chinese mainland squid jigging fleet in 2003-2004 and 2006-2013.The data for all years as well as the eight years (excluding E1 Ni(n)o events) were studied to examine the effect of climate variation on the spatial distribution of D.gigas.Five spatial clusters reflecting the spatial distribution were computed using K-means and Getis-Ord Gi* for a detailed comparative study.Our results showed that clusters identified by the two methods were quite different in terms of their spatial patterns,and K-means was not as accurate as Getis-Ord Gi*,as inferred from the agreement degree and receiver operating characteristic.There were more areas of hot and cold spots in years without the impact of El Ni(n)o,suggesting that such large-scale climate variations could reduce the clustering level ofD.gigas.The catches also showed that warm E1 Ni(n)o conditions and high water temperature were less favorable for D.gigas offshore Peru.The results suggested that the use of K-means is preferable if the aim is to discover the spatial distribution of each sub-region (cluster) of the study area,while Getis-Ord Gi* is preferable if the aim is to identify statistically significant hot spots that may indicate the central fishing ground.

  15. A comparative study of spatially clustered distribution of jumbo flying squid ( Dosidicus gigas) offshore Peru

    Science.gov (United States)

    Feng, Yongjiu; Cui, Li; Chen, Xinjun; Liu, Yu

    2017-06-01

    We examined spatially clustered distribution of jumbo flying squid ( Dosidicus gigas) in the offshore waters of Peru bounded by 78°-86°W and 8°-20°S under 0.5°×0.5° fishing grid. The study is based on the catch-per-unit-effort (CPUE) and fishing effort from Chinese mainland squid jigging fleet in 2003-2004 and 2006-2013. The data for all years as well as the eight years (excluding El Niño events) were studied to examine the effect of climate variation on the spatial distribution of D. gigas. Five spatial clusters reflecting the spatial distribution were computed using K-means and Getis-Ord Gi* for a detailed comparative study. Our results showed that clusters identified by the two methods were quite different in terms of their spatial patterns, and K-means was not as accurate as Getis-Ord Gi*, as inferred from the agreement degree and receiver operating characteristic. There were more areas of hot and cold spots in years without the impact of El Niño, suggesting that such large-scale climate variations could reduce the clustering level of D. gigas. The catches also showed that warm El Niño conditions and high water temperature were less favorable for D. gigas offshore Peru. The results suggested that the use of K-means is preferable if the aim is to discover the spatial distribution of each sub-region (cluster) of the study area, while Getis-Ord Gi* is preferable if the aim is to identify statistically significant hot spots that may indicate the central fishing ground.

  16. Potential use of stable isotope and fatty acid analyses for traceability of geographic origins of jumbo squid (Dosidicus gigas).

    Science.gov (United States)

    Gong, Yi; Li, Yunkai; Chen, Xinjun; Chen, Ling

    2018-04-15

    Squid is an important seafood resource for Asian and European countries. With the continuous development of processed squid products, an effective traceability system has become increasingly prominent. Here, we attempt to trace the fishery products of the main target species, jumbo squid (Dosidicus gigas), by using biochemical tracers. Carbon and nitrogen isotope ratios (δ 13 C and δ 15 N values) and fatty acid profiles were identified in squid from three harvest locations in the eastern Pacific Ocean by isotope ratio mass spectrometry and gas chromatography/mass spectrometry, respectively. Comparative analysis was used to evaluate the geographic variations in tracers and to identify the suitable discriminatory variables among origins. Significant spatial variations were found in isotopic values and fatty acid profiles in squid muscle tissues, possibly because of different food availability and/or oceanographic conditions that each group experiences at a given location. The stepwise discriminant analysis indicated that δ 15 N, C16:1n7, C17:1n7, C18:2n6, C20:1 and C20:4n6 were effective variables at differentiating origin. Combined use of stable isotope ratios and fatty acid analyses could trace geographic origins of jumbo squid. This study provides an alternative approach for improving authenticity evaluation of commercial squid products. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Pelvimetry and patient acceptability compared between open 0.5-T and closed 1.5-T MR systems

    International Nuclear Information System (INIS)

    Michel, Sven C.A.; Treiber, Karl; Marincek, Borut; Kubik-Huch, Rahel A.; Rake, Annett; Chaoui, Rabih; Keller, Thomas M.; Goetzmann, Lutz; Seifert, Burkhardt; Ferrazzini, Mattia

    2002-01-01

    Our objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan time was double in the open system (7:52±1:47 vs 3:12±1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences ≤120 cm. (orig.)

  18. Pelvimetry and patient acceptability compared between open 0.5-T and closed 1.5-T MR systems

    Energy Technology Data Exchange (ETDEWEB)

    Michel, Sven C.A.; Treiber, Karl; Marincek, Borut; Kubik-Huch, Rahel A. [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Rake, Annett; Chaoui, Rabih; Keller, Thomas M. [Department of Obstetrics, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetzmann, Lutz [Institute of Psychosocial Medicine, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Seifert, Burkhardt [Department of Biostatistics, University Hospital Zurich, Sumatrastrasse 30, 8006 Zurich (Switzerland); Department of Biostatistics, University Hospital Zurich, Sumatrastrasse 30, 8006 Zurich (Switzerland); Ferrazzini, Mattia [Department of Otorhinolaryngology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2002-12-01

    Our objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan time was double in the open system (7:52{+-}1:47 vs 3:12{+-}1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences {<=}120 cm. (orig.)

  19. Description of plastic remains found in the stomach contents of the jumbo squid Dosidicus gigas landed in Ecuador during 2014.

    Science.gov (United States)

    Rosas-Luis, Rigoberto

    2016-12-15

    Squids are active and opportunistic predators that feed on a wide range of prey. Their active movements in the water column and their voracity promote a high consumption of food. In the pelagic environment off Ecuador, marine pollution is characterized by plastic debris with a mainland origin, including plastics trash of fishing gears. The objective of this work was to describe the presence of plastic remains in the stomach contents of Dosidicus gigas caught off the coast of Ecuador. Results demonstrated that 12% of the stomachs contained plastic remains. These plastics were identified as multifilament of polyethylene lines and polyvinyl chloride remains. Findings of this work could be related to an increase in the discharge of solid materials in the water column, increasing the probability to be ingested by the jumbo squid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Evaluation of jumbo squid (Dosidicus gigas byproduct hydrolysates obtained by acid-enzymatic hydrolysis and by autohydrolysis in practical diets for Pacific white shrimp (Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    Mayra Lizett González-Félix

    2014-09-01

    Full Text Available The marine bioprocessing industry offers great potential to utilize byproducts for fish meal replacement in aquafeeds. Jumbo squid is an important fishery commodity in Mexico, but only the mantle is marketed. Head, fins, guts and tentacles are discarded in spite of being protein-rich byproducts. This study evaluated the use of two jumbo squid byproduct hydrolysates obtained by acid-enzymatic hydrolysis (AEH and by autohydrolysis (AH as ingredients in practical diets for shrimp. The hydrolysates were included at levels of 2.5 and 5.0% of the diet dry weight in four practical diets, including a control diet without hydrolysate. Shrimp growth and survival were not significantly affected by the dietary treatments. Postharvest quality of abdominal muscle was evaluated in terms of proximate composition and sensory evaluation. Significantly higher crude protein was observed in the muscle of shrimp fed the highest hydrolysate levels, AH 5% (204.8 g kg- 1 or AEH 5% (201.3 g kg- 1. Sensory analysis of cooked muscle showed significant differences for all variables evaluated: color, odor, flavor, and firmness. It was concluded that Jumbo squid byproducts can be successfully processed by autohydrolysis or acid-enzymatic hydrolysis, and that up to 5.0% of the hydrolysates can be incorporated into shrimp diets without affecting growth or survival.

  1. A Revival of Waste: Atmospheric Pressure Nitrogen Plasma Jet Enhanced Jumbo Silicon/Silicon Carbide Composite in Lithium Ion Batteries.

    Science.gov (United States)

    Chen, Bing-Hong; Chuang, Shang-I; Liu, Wei-Ren; Duh, Jenq-Gong

    2015-12-30

    In this study, a jumbo silicon/silicon carbide (Si/SiC) composite (JSC), a novel anode material source, was extracted from solar power industry cutting waste and used as a material for lithium-ion batteries (LIBs), instead of manufacturing the nanolized-Si. Unlike previous methods used for preventing volume expansion and solid electrolyte interphase (SEI), the approach proposed here simply entails applying surface modification to JSC-based electrodes by using nitrogen-atmospheric pressure plasma jet (N-APPJ) treatment process. Surface organic bonds were rearranged and N-doped compounds were formed on the electrodes through applying different plasma treatment durations, and the qualitative examinations of before/after plasma treatment were identified by X-ray photoelectron spectroscopy (XPS) and electron probe microanalyzer (EPMA). The surface modification resulted in the enhancement of electrochemical performance with stable capacity retention and high Coulombic efficiency. In addition, depth profile and scanning electron microscope (SEM) images were executed to determine the existence of Li-N matrix and how the nitrogen compounds change the surface conditions of the electrodes. The N-APPJ-induced rapid surface modification is a major breakthrough for processing recycled waste that can serve as anode materials for next-generation high-performance LIBs.

  2. Extreme plasticity in life-history strategy allows a migratory predator (jumbo squid) to cope with a changing climate.

    Science.gov (United States)

    Hoving, Henk-Jan T; Gilly, William F; Markaida, Unai; Benoit-Bird, Kelly J; -Brown, Zachary W; Daniel, Patrick; Field, John C; Parassenti, Liz; Liu, Bilin; Campos, Bernardita

    2013-07-01

    Dosidicus gigas (jumbo or Humboldt squid) is a semelparous, major predator of the eastern Pacific that is ecologically and commercially important. In the Gulf of California, these animals mature at large size (>55 cm mantle length) in 1-1.5 years and have supported a major commercial fishery in the Guaymas Basin during the last 20 years. An El Niño event in 2009-2010, was accompanied by a collapse of this fishery, and squid in the region showed major changes in the distribution and life-history strategy. Large squid abandoned seasonal coastal-shelf habitats in 2010 and instead were found in the Salsipuedes Basin to the north, an area buffered from the effects of El Niño by tidal upwelling and a well-mixed water column. The commercial fishery also relocated to this region. Although large squid were not found in the Guaymas Basin from 2010 to 2012, small squid were abundant and matured at an unusually small mantle-length (adapt to and cope with El Niño. This ability is likely to be an important factor in conjunction with longerterm climate-change and the potential ecological impacts of this invasive predator on marine ecosystems. © 2013 Blackwell Publishing Ltd.

  3. The exhausted CD4+CXCR5+ T cells involve the pathogenesis of human tuberculosis disease.

    Science.gov (United States)

    Bosco, Munyemana Jean; Wei, Ming; Hou, Hongyan; Yu, Jing; Lin, Qun; Luo, Ying; Sun, Ziyong; Wang, Feng

    2018-06-21

    The CD4 + CXCR5 + T cells have been previously established. However, their decreased frequency during tuberculosis (TB) disease is partially understood. The aim of this study was to explore the depletion of CD4 + CXCR5 + T cells in human TB. The frequency and function of CD4 + CXCR5 + T cells were evaluated in active TB (ATB) patients and healthy control (HC) individuals. The function of CD4 + CXCR5 + T cells was determined after blockade of inhibitory receptors. The frequency of CD4 + CXCR5 + T cells was decreased in ATB patients. The expression of activation markers (HLA-DR and ICOS) and inhibitory receptors (Tim-3 and PD-1) on CD4 + CXCR5 + T cells was increased in ATB group. TB-specific antigen stimulation induced higher expression of inhibitory receptors than phytohemagglutinin stimulation in ATB group. In contrast, TB antigen stimulation did not induce a significantly increased expression of IL-21 and Ki-67 on CD4 + CXCR5 + T cells. However, blockade of inhibitory receptors Tim-3 and PD-1 not only increased the frequency of CD4 + CXCR5 + T cells, but also restored their proliferation and cytokine secretion potential. An increased expression of inhibitory receptors involves the depletion of CD4 + CXCR5 + T cells, and blockade of inhibitory receptors can restore the function of CD4 + CXCR5 + T cells in ATB patients. Copyright © 2018. Published by Elsevier Ltd.

  4. Fishery biology of the jumbo flying squid Dosidicus gigas off the Exclusive Economic Zone of Chilean waters

    Directory of Open Access Journals (Sweden)

    Bilin Liu

    2010-11-01

    Full Text Available The jumbo flying squid Dosidicus gigas is widely distributed in the eastern Pacific Ocean and supports an important fishery. Although many studies have been carried out on the biology of this species, limited biological information is available in the waters outside the Exclusive Economic Zone of Chile (EEZ (20°S-41°S and 74°30’W-84°W. Three surveys were conducted in this area by the Chinese squid jigging vessels during the period from April 2006 to May 2008. The majority of the catch in the survey was from the two areas defined by 37°30’-41°S and 78°30’-80°W and by 25°-30°S and 76°-77°30’W. The sex ratio (M: F of the catch was 1: 2.48. The mean mantle length (ML was 376 mm for males with a range of 257-721 mm and 388.7 mm for females with a range of 236-837 mm. Two distinguished size classes, medium- and large-sized groups, were identified in this study with the medium-sized group (350-450 mm ML consisting of 89% of the total catch. The sizes at first sexual maturity were 638 mm ML for females and 565 mm ML for males. This study suggests that all the individuals examined were hatched from March 2007 to February 2008, indicating that D. gigas might spawn all year around with a peak spawning time from November 2007 to January 2008. Most of the stomachs analyzed had food remains. The preys included three major groups: fish (mainly lanternfish, cephalopods and crustaceans, but D. gigas was the dominant species in the stomach contents, showing strong evidence of cannibalism. The information obtained from this study improves our understanding of the fishery biology of D. gigas off Chile.

  5. Infratentorial brain maturation: a comparison of MRI at 0.5 and 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hittmair, K. [MR Institute, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kramer, J. [MR Institute, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Rand, T. [Department of Diagnostic Radiology, University of Vienna, Vienna (Austria); Bernert, G. [Department of Paediatrics, University of Vienna, Vienna (Austria); Wimberger, D. [Department of Diagnostic Radiology, University of Vienna, Vienna (Austria)

    1996-05-01

    Our purpose was to establish parameters for normal infratentorial brain maturation at 0.5 and 1.5 T and to evaluate the field strength criteria for the assessment of infratentorial brain maturation with MRI. We examined 27 children with normal psychomotor development (3 days to 24 months) with a 1.5 T system and 22 (4 days to 29 months) with a 0.5 T system; standard T2-weighted spin-echo sequences (TR/TE 2 500/90 ms at 1.5 T and TR/TE 2 200/90 ms at 0.5 T) were obtained. The signal intensity of infratentorial anatomical structures compared to their surroundings was classified as high, isointense or low by three neuroradiologists. For anatomical structures with age-related contrast changes, the time of these changes was determined statistically for the 0.5 T and 1.5 T system independently. The delineation of the structures without age-related contrast changes at the two field strengths was compared using a {chi} {sup 2} test. Age-related contrast changed were found in the same anatomical structures (``marker sites``) at 0.5 and 1.5 T. Generally, these changes were apparent in larger structures (pons, middle cerebellar peduncles, medulla, cerebellar folia, red nuclei, cerebral peduncles), with only slight field-strength-dependent differences in the time of the contrast changes. Contrast changes from high to isointense signal were observed slightly earlier at 0.5 T and changes from isointense to low signal slightly later at 0.5 T. The delineation of the smaller anatomical structures was significantly better at 1.5 T but these structures did not show age-related contrast changes. The differences in the assessment of infratentorial brian maturation between 0.5 and 1.5 T can be attributed to a lower signal-to-noise ratio at lower magnetic field strengths. These differences do not complicate temporal classification of the stage of infratentorial brain maturation using the same ``marker sites`` and the same temporal criteria at 0.5 or 1.5 T. (orig.). With 4 figs., 2 tabs.

  6. Infratentorial brain maturation: a comparison of MRI at 0.5 and 1.5 T

    International Nuclear Information System (INIS)

    Hittmair, K.; Kramer, J.; Rand, T.; Bernert, G.; Wimberger, D.

    1996-01-01

    Our purpose was to establish parameters for normal infratentorial brain maturation at 0.5 and 1.5 T and to evaluate the field strength criteria for the assessment of infratentorial brain maturation with MRI. We examined 27 children with normal psychomotor development (3 days to 24 months) with a 1.5 T system and 22 (4 days to 29 months) with a 0.5 T system; standard T2-weighted spin-echo sequences (TR/TE 2 500/90 ms at 1.5 T and TR/TE 2 200/90 ms at 0.5 T) were obtained. The signal intensity of infratentorial anatomical structures compared to their surroundings was classified as high, isointense or low by three neuroradiologists. For anatomical structures with age-related contrast changes, the time of these changes was determined statistically for the 0.5 T and 1.5 T system independently. The delineation of the structures without age-related contrast changes at the two field strengths was compared using a χ 2 test. Age-related contrast changed were found in the same anatomical structures (''marker sites'') at 0.5 and 1.5 T. Generally, these changes were apparent in larger structures (pons, middle cerebellar peduncles, medulla, cerebellar folia, red nuclei, cerebral peduncles), with only slight field-strength-dependent differences in the time of the contrast changes. Contrast changes from high to isointense signal were observed slightly earlier at 0.5 T and changes from isointense to low signal slightly later at 0.5 T. The delineation of the smaller anatomical structures was significantly better at 1.5 T but these structures did not show age-related contrast changes. The differences in the assessment of infratentorial brian maturation between 0.5 and 1.5 T can be attributed to a lower signal-to-noise ratio at lower magnetic field strengths. These differences do not complicate temporal classification of the stage of infratentorial brain maturation using the same ''marker sites'' and the same temporal criteria at 0.5 or 1.5 T. (orig.). With 4 figs., 2 tabs

  7. Asthma and COPD in cystic fibrosis intron-8 5T carriers. A population-based study

    DEFF Research Database (Denmark)

    Dahl, Morten; Tybjaerg-Hansen, Anne; Lange, Peter

    2005-01-01

    Carriers of cystic fibrosis intron-8 5T alleles with high exon-9 skipping could have increased annual lung function decline and increased risk for asthma or chronic obstructive pulmonary disease (COPD).......Carriers of cystic fibrosis intron-8 5T alleles with high exon-9 skipping could have increased annual lung function decline and increased risk for asthma or chronic obstructive pulmonary disease (COPD)....

  8. The Effects of the Recombinant CCR5 T4 Lysozyme Fusion Protein on HIV-1 Infection.

    Directory of Open Access Journals (Sweden)

    Qingwen Jin

    Full Text Available Insertion of T4 lysozyme (T4L into the GPCR successfully enhanced GPCR protein stability and solubilization. However, the biological functions of the recombinant GPCR protein have not been analyzed.We engineered the CCR5-T4L mutant and expressed and purified the soluble recombinant protein using an E.coli expression system. The antiviral effects of this recombinant protein in THP-1 cell lines, primary human macrophages, and PBMCs from different donors were investigated. We also explored the possible mechanisms underlying the observed antiviral effects.Our data showed the biphasic inhibitory and promotion effects of different concentrations of soluble recombinant CCR5-T4L protein on R5 tropic human immunodeficiency virus-1 (HIV-1 infection in THP-1 cell lines, human macrophages, and PBMCs from clinical isolates. We demonstrated that soluble recombinant CCR5-T4L acts as a HIV-1 co-receptor, interacts with wild type CCR5, down-regulates the surface CCR5 expression in human macrophages, and interacts with CCL5 to inhibit macrophage migration. Using binding assays, we further determined that recombinant CCR5-T4L and [125I]-CCL5 compete for the same binding site on wild type CCR5.Our results suggest that recombinant CCR5-T4L protein marginally promotes HIV-1 infection at low concentrations and markedly inhibits infection at higher concentrations. This recombinant protein may be helpful in the future development of anti-HIV-1 therapeutic agents.

  9. Deficient Fas expression by CD4+ CCR5+ T cells in multiple sclerosis

    DEFF Research Database (Denmark)

    Julià, Eva; Montalban, Xavier; Al-Zayat, Hammad

    2006-01-01

    OBJECTIVE: To evaluate whether T cells expressing CCR5 and CXCR3 from multiple sclerosis (MS) patients are more resistant to apoptosis. METHODS: Expression of CD69, TNF-R1, Fas, FasL, bcl-2, and bax was investigated in 41 MS patients and 12 healthy controls by flow cytometry in CD4+ and CD8+ T...... cells expressing CCR5 and CXCR3. RESULTS: In MS patients, the percentage of CD69 was increased and Fas expression decreased in CD4+ CCR5+ T cells. INTERPRETATION: The lower Fas expression in activated CD4+ CCR5+ T cells might contribute to disease pathogenesis by prolonging cell survival and favoring...

  10. Indigenous design and fabrication of a 6.5 T superconducting ...

    Indian Academy of Sciences (India)

    This includes a 6.5 T superconducting magnet and a vari- able temperature .... tronics) Hall sensor (of sensitivity ~10 µV/Oe at 5 mA DC excitation) by moving it to various axial positions and the measured coil constant is found to be very close ... developed across the magnet makes either of the diodes to conduct and allows.

  11. Complete genome sequence of Paenibacillus riograndensis SBR5(T), a Gram-positive diazotrophic rhizobacterium.

    Science.gov (United States)

    Brito, Luciana Fernandes; Bach, Evelise; Kalinowski, Jörn; Rückert, Christian; Wibberg, Daniel; Passaglia, Luciane M; Wendisch, Volker F

    2015-08-10

    Paenibacillus riograndensis is a Gram-positive rhizobacterium which exhibits plant growth promoting activities. It was isolated from the rhizosphere of wheat grown in the state of Rio Grande do Sul, Brazil. Here we announce the complete genome sequence of P. riograndensis strain SBR5(T). The genome of P. riograndensis SBR5(T) consists of a circular chromosome of 7,893,056bps. The genome was finished and fully annotated, containing 6705 protein coding genes, 87 tRNAs and 27 rRNAs. The knowledge of the complete genome helped to explain why P. riograndensis SBR5(T) can grow with the carbon sources arabinose and mannitol, but not myo-inositol, and to explain physiological features such as biotin auxotrophy and antibiotic resistances. The genome sequence will be valuable for functional genomics and ecological studies as well as for application of P. riograndensis SBR5(T) as plant growth-promoting rhizobacterium. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Multiple adrenal masses: MRI tissue differentiation of pheochromocytoma and adenoma at 1.5 T

    International Nuclear Information System (INIS)

    Slapa, R.Z.; Jakubowski, W.; Feltynowski, T.; Januszewicz, A.

    1997-01-01

    We present the case of 38-year-old hypertensive patient with bilateral adrenal masses and with clinical and biochemical suspicion of pheochromocytoma. Magnetic resonance imaging at 1.5 T established correct diagnosis of coexisting adrenal pheochromocytoma and adenoma (nonhyperfunctioning). The case supports the usefulness of MRI for definitive evaluation of bilateral adrenal masses in patients with suspicion of pheochromocytoma. (orig.). With 2 figs

  13. Mechanical behaviour of a closed collar model for an 11.5 T dipole magnet

    International Nuclear Information System (INIS)

    Emden, W. van; Daum, C.; Geerinck, J.

    1992-03-01

    A 10 cm long model of an 11.5 T Nb 3 Sn accelerator dipole magnet, which will be built in the Netherlands, with a closed ring shaped collar has been constructed. Measurements of the collar deformation and the prestress at the poles have been made with a structural analysis using the Finite Element Method (FEM) of the code ANSYS. (author). 11 refs.; 18 figs.; 7 tabs

  14. Quantification of dextrose in model solution by 1H MR spectroscopy at 1.5T

    International Nuclear Information System (INIS)

    Lee, Kyung Hee; Cho, Soon Gu; Kim, Hyung Jin; Suh, Chang Hae; Kim, Yong Seong; Lee, Jung Hee

    2002-01-01

    To evaluate the feasibility of proton magnetic resonance spectroscopy ( 1 H-MRS) using a 1.5T magnetic resonance (MR) imager for quantification of the contents of model solutions. We prepared model solutions of dextrose +water and dextrose +water + ethanol at dextrose concentrations of 0.01% to 50% and 0.01% to 20%, respectively. Using these solutions and a 1.5T MR imager together with a high-resolution nuclear magnetic resonance (NMR) spectroscope, we calculated the ratios of dextrose to water peak, (dextrose +ethanol) to water peak, and (dextrose + ethanol) to ethanol peak, as seen on MR and NMR spectra, analysing the relationships between dextrose concentration and the ratios of peaks, and between the ratios of the peaks seen on MR spectra and those seen on NMR spectra. Changes in the ratios between dextrose concentration and dextrose to water peak, (dextrose + ethanol) to water peak and (dextrose + ethanol) to ethanol peak, as seen on MR spectra, were statistically significant, and there was good linear regression. There was also close correlation between the ratios of the observed on MR and NMR spectra. The results depict the quantification of dextrose concentration according to the ratios of spectral peaks obtained by proton MRS at 1.5T. Using proton MRS at 1.5T, and on the basis of the ratios of spectcal peaks, it was possible to quantify the concentration of dextrose in model solutions of dextrose + water and dextrose + water+ ethanol. The results of this study suggest that for quantifying the contents of biofluids, the use of low-tesla 1 H-MRS is feasible

  15. Clinical advantages of 3.0 T MRI over 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Willinek, Winfried A. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)], E-mail: winfried.willinek@ukb.uni-bonn.de; Schild, Hans H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2008-01-15

    Since approval by the FDA in 2000, human MR imaging (MRI) at 3.0 T has been increasingly used in clinical practice. In spite of the potential technical challenges, a number of clinical advantages of 3.0 T MRI over 1.5 T have been identified in the recent years. This article reviews the benefits and the current knowledge of 3.0 T whole-body MRI from an evidence-based perspective and summarizes its clinical applications.

  16. Clinical advantages of 3.0 T MRI over 1.5 T

    International Nuclear Information System (INIS)

    Willinek, Winfried A.; Schild, Hans H.

    2008-01-01

    Since approval by the FDA in 2000, human MR imaging (MRI) at 3.0 T has been increasingly used in clinical practice. In spite of the potential technical challenges, a number of clinical advantages of 3.0 T MRI over 1.5 T have been identified in the recent years. This article reviews the benefits and the current knowledge of 3.0 T whole-body MRI from an evidence-based perspective and summarizes its clinical applications

  17. The first steps towards a 7.5 T superconducting wiggler

    International Nuclear Information System (INIS)

    Werin, S.

    1988-01-01

    A 7.5 T superconducting wiggler is currently beeing constructed in cooperation between MAX-lab and the Institute of Technology in Tammerfors, Finland. The wiggler will be places at MAX-lab, either at the existing 550 MeV storage ring or at a future 1.2 GeV ring. In this paper some basic designs and calculations are described and discussed. (author)

  18. Preclinical evaluation of invariant natural killer T cells in the 5T33 multiple myeloma model.

    Directory of Open Access Journals (Sweden)

    Haneen Nur

    Full Text Available Immunomodulators have been used in recent years to reactivate host anti-tumor immunity in several hematological malignancies. This report describes the effect of activating natural killer T (NKT cells by α-Galactosylceramide (α-GalCer in the 5T33MM model of multiple myeloma (MM. NKT cells are T lymphocytes, co-expressing T and NK receptors, while invariant NKT cells (iNKTs also express a unique semi-invariant TCR α-chain. We followed iNKT numbers during the development of the disease in both 5T33MM mice and MM patients and found that their numbers dropped dramatically at the end stage of the disease, leading to a loss of total IFN-γ secretion. We furthermore observed that α-GalCer treatment significantly increased the survival of 5T33MM diseased mice. Taken together, our data demonstrate for the first time the possibility of using a preclinical murine MM model to study the effects of α-GalCer and show promising results of α-GalCer treatment in a low tumor burden setting.

  19. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.

    Science.gov (United States)

    Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan

    2017-01-01

    The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.

  20. Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation

    DEFF Research Database (Denmark)

    Henriksen, O; Larsson, H B; Ring, P

    1993-01-01

    A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms....... The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation....

  1. Chang?E-5T Orbit Determination Using Onboard GPS Observations

    OpenAIRE

    Su, Xing; Geng, Tao; Li, Wenwen; Zhao, Qile; Xie, Xin

    2017-01-01

    In recent years, Global Navigation Satellite System (GNSS) has played an important role in Space Service Volume, the region enclosing the altitudes above 3000 km up to 36,000 km. As an in-flight test for the feasibility as well as for the performance of GNSS-based satellite orbit determination (OD), the Chinese experimental lunar mission Chang?E-5T had been equipped with an onboard high-sensitivity GNSS receiver with GPS and GLONASS tracking capability. In this contribution, the 2-h onboard G...

  2. Genome Analysis of Fimbriiglobus ruber SP5T, a Planctomycete with Confirmed Chitinolytic Capability.

    Science.gov (United States)

    Ravin, Nikolai V; Rakitin, Andrey L; Ivanova, Anastasia A; Beletsky, Alexey V; Kulichevskaya, Irina S; Mardanov, Andrey V; Dedysh, Svetlana N

    2018-04-01

    Members of the bacterial order Planctomycetales have often been observed in associations with Crustacea. The ability to degrade chitin, however, has never been reported for any of the cultured planctomycetes although utilization of N -acetylglucosamine (GlcNAc) as a sole carbon and nitrogen source is well recognized for these bacteria. Here, we demonstrate the chitinolytic capability of a member of the family Gemmataceae , Fimbriiglobus ruber SP5 T , which was isolated from a peat bog. As revealed by metatranscriptomic analysis of chitin-amended peat, the pool of 16S rRNA reads from F. ruber increased in response to chitin availability. Strain SP5 T displayed only weak growth on amorphous chitin as a sole source of carbon but grew well with chitin as a source of nitrogen. The genome of F. ruber SP5 T is 12.364 Mb in size and is the largest among all currently determined planctomycete genomes. It encodes several enzymes putatively involved in chitin degradation, including two chitinases affiliated with the glycoside hydrolase (GH) family GH18, GH20 family β- N -acetylglucosaminidase, and the complete set of enzymes required for utilization of GlcNAc. The gene encoding one of the predicted chitinases was expressed in Escherichia coli , and the endochitinase activity of the recombinant enzyme was confirmed. The genome also contains genes required for the assembly of type IV pili, which may be used to adhere to chitin and possibly other biopolymers. The ability to use chitin as a source of nitrogen is of special importance for planctomycetes that inhabit N-depleted ombrotrophic wetlands. IMPORTANCE Planctomycetes represent an important part of the microbial community in Sphagnum -dominated peatlands, but their potential functions in these ecosystems remain poorly understood. This study reports the presence of chitinolytic potential in one of the recently described peat-inhabiting members of the family Gemmataceae , Fimbriiglobus ruber SP5 T This planctomycete uses

  3. Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation

    DEFF Research Database (Denmark)

    Henriksen, O; Larsson, H B; Ring, P

    1993-01-01

    A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms........ The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation....

  4. Disorders of migration and sulcation in infants and children: MR spectrum at 1.5 T

    International Nuclear Information System (INIS)

    Boyer, R.S.; Nixon, G.W.; Smoker, W.R.K.; Harnsberger, H.R.; Osborn, A.G.

    1987-01-01

    In 750 consecutive high-field-strength (1.5-T) pediatric brain MR imaging studies the authors encountered a fascinating spectrum of developmental anomalies of migration, gyration, and sulcation in 11 patients. Lesions were characterized by disorder anatomy but normal gray-matter signal. MR imaging was excellent in revealing pachygyria, polymicrogyria, agyria (lissencephaly), heterotopia, and schizencephaly, and in displaying associated development anomalies, such as agenesis of the corpus callosum, encephalocele, Chiari II malformation, septo-optic dysplasia, lobar holoprosencephaly, and unilateral megalencephaly. The improved demonstration of gray-matter abnormalities that is possible with high-field-strength MR imaging facilitates recognition of these lesions and associated anomalies

  5. Relaxivity of Ferumoxytol at 1.5 T and 3.0 T.

    Science.gov (United States)

    Knobloch, Gesine; Colgan, Timothy; Wiens, Curtis N; Wang, Xiaoke; Schubert, Tilman; Hernando, Diego; Sharma, Samir D; Reeder, Scott B

    2018-05-01

    The aim of this study was to determine the relaxation properties of ferumoxytol, an off-label alternative to gadolinium-based contrast agents, under physiological conditions at 1.5 T and 3.0 T. Ferumoxytol was diluted in gradually increasing concentrations (0.26-4.2 mM) in saline, human plasma, and human whole blood. Magnetic resonance relaxometry was performed at 37°C at 1.5 T and 3.0 T. Longitudinal and transverse relaxation rate constants (R1, R2, R2*) were measured as a function of ferumoxytol concentration, and relaxivities (r1, r2, r2*) were calculated. A linear dependence of R1, R2, and R2* on ferumoxytol concentration was found in saline and plasma with lower R1 values at 3.0 T and similar R2 and R2* values at 1.5 T and 3.0 T (1.5 T: r1saline = 19.9 ± 2.3 smM; r1plasma = 19.0 ± 1.7 smM; r2saline = 60.8 ± 3.8 smM; r2plasma = 64.9 ± 1.8 smM; r2*saline = 60.4 ± 4.7 smM; r2*plasma = 64.4 ± 2.5 smM; 3.0 T: r1saline = 10.0 ± 0.3 smM; r1plasma = 9.5 ± 0.2 smM; r2saline = 62.3 ± 3.7 smM; r2plasma = 65.2 ± 1.8 smM; r2*saline = 57.0 ± 4.7 smM; r2*plasma = 55.7 ± 4.4 smM). The dependence of relaxation rates on concentration in blood was nonlinear. Formulas from second-order polynomial fittings of the relaxation rates were calculated to characterize the relationship between R1blood and R2 blood with ferumoxytol. Ferumoxytol demonstrates strong longitudinal and transverse relaxivities. Awareness of the nonlinear relaxation behavior of ferumoxytol in blood is important for ferumoxytol-enhanced magnetic resonance imaging applications and for protocol optimization.

  6. Clinical application for cardiovascular diseases using 1.5 T senior MR

    International Nuclear Information System (INIS)

    Zhao Shihua; Lu Minjie; Zhang Yan; Jiang Shiliang; Huang Lianjun; Wang Hongyu; Wu Yanling; Du Mojia; Liu Yuqing

    2005-01-01

    Objective: To assess the clinical value of 1.5 T senior magnet for cardiovascular diseases. Methods: A total of 355 cases with cardiovascular diseases were studied. One stop shop scanning included HASTE and TSE for morphology, TrueFisp for cine-MRI, TurboFlash for fist pass myocardial perfusion, PSIR TrueFisp and PSIR Turbo Flash for late enhancement, as well as Flash3D plus multiple planar reconstruction for contrast enhanced MR angiography. Results: Abnormal findings were reported in 158 cases in the present study. Those positive patients had 35 cases with coronary heart diseases, of which normal or slightly enlarged left ventricular cavity (n=19), considerably enlarged left ventricular cavity (n=16), aneurysum (n=13), regional wall thinning (n=30), hypokinesia or akinesia (n=33), myocardial perfusion defect (n=20) and late enhancement (n=25) were demonstrated. Others included cardiomyopathy (n=52), pericardial diseases (n=9), vessel diseases (n=34), valvular diseases (n=6), high blood pressure (n=6), congenital heart diseases (n=5), pulmonary embolism (n=4), cardiac tumors (n=7), respectively. Conclusion: One stop shop scanning with 1.5 T senior magnet can provide well- qualified images of the heart and great vessels for the morphology, wall motion and myocardial viability. (authors)

  7. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon

    1995-01-01

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected

  8. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon [Gyeongsang National University, College of Medicine, Jeongju (Korea, Republic of)

    1995-07-15

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected.

  9. Complete genome sequence of Pseudomonas rhizosphaerae IH5T (=DSM 16299T), a phosphate-solubilizing rhizobacterium for bacterial biofertilizer.

    Science.gov (United States)

    Kwak, Yunyoung; Jung, Byung Kwon; Shin, Jae-Ho

    2015-01-10

    Pseudomonas rhizosphaerae IH5(T) (=DSM 16299(T)), isolated from the rhizospheric soil of grass growing in Spain, has been reported as a novel species of the genus Pseudomonas harboring insoluble phosphorus solubilizing activity. To understanding the multifunctional biofertilizer better, we report the complete genome sequence of P. rhizosphaerae IH5(T). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Administration of 3,5-diiodothyronine (3,5-T2) causes central hypothyroidism and stimulates thyroid-sensitive tissues.

    Science.gov (United States)

    Padron, Alvaro Souto; Neto, Ruy Andrade Louzada; Pantaleão, Thiago Urgal; de Souza dos Santos, Maria Carolina; Araujo, Renata Lopes; de Andrade, Bruno Moulin; da Silva Leandro, Monique; de Castro, João Pedro Saar Werneck; Ferreira, Andrea Claudia Freitas; de Carvalho, Denise Pires

    2014-06-01

    In general, 3,5-diiodothyronine (3,5-T2) increases the resting metabolic rate and oxygen consumption, exerting short-term beneficial metabolic effects on rats subjected to a high-fat diet. Our aim was to evaluate the effects of chronic 3,5-T2 administration on the hypothalamus-pituitary-thyroid axis, body mass gain, adipose tissue mass, and body oxygen consumption in Wistar rats from 3 to 6 months of age. The rats were treated daily with 3,5-T2 (25, 50, or 75 μg/100 g body weight, s.c.) for 90 days between the ages of 3 and 6 months. The administration of 3,5-T2 suppressed thyroid function, reducing not only thyroid iodide uptake but also thyroperoxidase, NADPH oxidase 4 (NOX4), and thyroid type 1 iodothyronine deiodinase (D1 (DIO1)) activities and expression levels, whereas the expression of the TSH receptor and dual oxidase (DUOX) were increased. Serum TSH, 3,3',5-triiodothyronine, and thyroxine were reduced in a 3,5-T2 dose-dependent manner, whereas oxygen consumption increased in these animals, indicating the direct action of 3,5-T2 on this physiological variable. Type 2 deiodinase activity increased in both the hypothalamus and the pituitary, and D1 activities in the liver and kidney were also increased in groups treated with 3,5-T2. Moreover, after 3 months of 3,5-T2 administration, body mass and retroperitoneal fat pad mass were significantly reduced, whereas the heart rate and mass were unchanged. Thus, 3,5-T2 acts as a direct stimulator of energy expenditure and reduces body mass gain; however, TSH suppression may develop secondary to 3,5-T2 administration. © 2014 The authors.

  11. Synthesis, purification and characterization of [3,5 - T] p-aminobenzoic acid

    International Nuclear Information System (INIS)

    Corol-Cucu, Delia-Irina; Chiper, Diana; Mihaila, V.; Negoita, N.

    2000-01-01

    This paper refers to the synthesis, purification and characterization of [3,5-T] p-aminobenzoic acid (PAB,H' vitamine). The p-aminobenzoic acid is used in the treatment of rheumatic arthritis and dermatological affections. The advantage of tritium labelling of p-aminobenzoic acid is that some biomedical important aspects of collagen's behaviour are made clear. The PAB stimulate the grow of intestinal bacteria so necessary to synthesis of some vitamins (bio tine, pantothenic acid). Tritium is the only radioactive isotope of hydrogen. Several steps have to be carried out in the synthesis of the final product as well as to study its biological behavior. For the labelling of PAB one prefers the substitution of bromine from PAB-3,5-Br with tritium because of simplicity of reaction and the easy synthesis of halogen compound. The first step in synthesis is the protection of NH 2 group through acetylation of PAB. After that PAB is bromated into the 3 and 5 position with elementary bromine. The raw compound is purified and recrystallized and characterized through thin layer chromatography.The tritium labelling is performed through substitution of bromine from bromate derivative, using Pd/C (10% Pd) as catalyst and low basic conditions for the neutralization of HBr resulting from reaction. After the separation of PAB-3,5-T through filtration, the catalyst remains on the filter paper and the labelled compound goes in aqueous solution. PAB-3,5-T is purified through thin layer chromatography with the solvent system n-BuOH:NH 4 OH(25%):H 2 O:EtOH (8:1:2:2,5, v/v) with silica gel GF 254 as support. The determination of activity is carried out with LSC (Liquid Scintillation Counter). A 98% purity was determined through TLC in the same conditions while determination of activity distribution was performed with a 2π Berthold scanner with gas running and without window. The chemical concentration has been measured through UV spectrophotometry and by comparing extinction with

  12. Evaluation of intracranial hemorrhage with high field MR Imaging (1. 5T)

    Energy Technology Data Exchange (ETDEWEB)

    Campodonico, F; Brienza, G; Cotroneo, E; Fabbrini, G

    1989-01-01

    Fifty-two patients were studied with high-field Magnetic Resonance imaging (1.5T), with T1- and T2-weighted spin-echo pulse sequences. The study was aimed at assessing the efficacy of MR imaging in the evaluation of intracranical hematomas. Characteristic intensity patterns were observed in the evolution of the hematomas, were observed. In 35 sub-acute hematomas, peripheral hyperintensity could be observed on T1- and T2. weighted pulse sequences. This hyper intensity eventually fills in the hematoma in the chronic stage. In 17 chronic hematomas, a peripheral hypointense ring due to hemosidering deposits was seen on T1- and T2- weighted scans. The authors conclude that high field MR imaging is a very sensible diagnostic method in the evaluation of sub-acute and chronic hematomas. 18 refs.

  13. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  14. Natural abundant (17) O NMR in a 1.5-T Halbach magnet.

    Science.gov (United States)

    Sørensen, Morten K; Bakharev, Oleg N; Jensen, Ole; Nielsen, Niels Chr

    2016-06-01

    We present mobile, low-field (17) O NMR as a means for monitoring oxygen in liquids. Whereas oxygen is one of the most important elements, oxygen NMR is limited by a poor sensitivity related to low natural abundance and gyro-magnetic ratio of the NMR active (17) O isotope. Here, we demonstrate (17) O NMR detection at a Larmor frequency of 8.74 MHz in a 1.5-T Halbach neodymium magnet with a home-built digital NMR instrument suitable for large-scale production and in-line monitoring applications. The proposed (17) O NMR sensor may be applied for direct, noninvasive measurements of water content in, for example, oil, manure, or food in automated quality or process control. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. [Musculoskeletal biopsies in an open 0.5-T-MR system].

    Science.gov (United States)

    Pretzsch, M; Scholz, R; Moche, M; Thomas, M; Tannapfel, A; von Salis-Soglio, G

    2005-01-01

    MR-guided interventions have been successful in different medical disciplines. The aim of this paper is to report our results with the application of MR-guided biopsies of musculoskeletal lesions using an open 0.5-T-MR scanner and further to discuss these results on the basis of the available literature. Between 1998 and 2003 30 patients (average age 44.1 years) underwent a total of 31 biopsies. The interventions were performed in an open 0.5-T MRI system using an active optical localization system as well as a navigation system. For the motion tracking we used T (1)-weighted real-time sequences with 0.25 pictures per second. For the sampling MR-compatible instruments were used that were specially developed for this purpose. The data of this retrospective investigation are based on the evaluation of the patient documents and the radiological findings. On the basis of the histological findings the technical success rate and the histological overall accuracy were determined. In 81 % of the biopsies the histological diagnosis was correct. In cases of suspected inflammation the histological accuracy was smaller (70 %). No differences were observed between skeletal and soft-tissue lesions. The technical success rate amounted to 77.5 %. No procedural or anesthesiological complications occurred. The mean operating time amounted to 65 min including the time for motion tracking. In cases of suspected lesions of the musculoskeletal system, the MR-guided biopsy represents a promising and safe procedure to get a histological diagnosis. In cases of sufficient size of the lesion sampling of a representative probe is possible. On account of the outstanding performance in soft-part contrasting, the sensitive structures surrounding the lesion can be saved. Substantial disadvantages of the procedure are the high costs for personal and material and the long operating time.

  16. Assessment of magnetic resonance imaging of the breast using 0.5 T equipment

    International Nuclear Information System (INIS)

    Vilanova, J. C.; Barcelo, J.; Ferrer, J.; Castaner, F.; Miro, J.; Bassaganyas, R.; Viejo, N.; Albanell, J.; Villalon, M.

    2002-01-01

    To evaluate the efficacy of a magnetic resonance imaging technique of the breast using half-field equipment (0.5 T). We evaluated 191 magnetic resonance (MRI) studies made at our center from March 1998 to March 2001 using Signa Contour 0.5 T MRI equipment of General Electric. A dedicated bilateral breast made at fat saturation in the coronal plane before administering intravenous gadolinium, then 6 consecutive times after contrast administration. The sequence acquisition time was 70-90 seconds Image post processing included subtraction and analysis of the intensity/time curves in the region of interest (ROI) together with morphological evaluation of the lesion. Additional T2 weighted fast-spin-echo sequences (FSE T2), T1-weighted spin-echo (SE T1), FSE T2 with fat suppression, and STIR with water saturation were made for studies of breast implants. The clinical indications for MRI study of the breast were masses (n=79), microcalcifications (n=7), asymmetry (n=17), cases of indeterminate risk (n=7), postoperative control (n=51), and breast implants (n=25). The histological diagnosis was benign in 31 lesions and malignant in 73 lesions. The sensitivity specificity, and reliability of breast MRI were 93%, 81% and 89% respectively. Multicenter/multifocal neoplasms were found in 8% of patients and bilateral neoplasms in 2%. The therapeutic attitude was modified in 18% of the patients with breast cancer as a result of MRI findings. The results confirm the usefulness of MRI in the management of patients with breast cancer. Likewise, the present study demonstrated that breast MRI can be carried out with half-field equipment with the same reliability as with full-field equipment as long as specific breast cots are used rapid 3D sequences, and image processing with suitable software. (Author) 28 refs

  17. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Naehle, Claas P; Strach, Katharina; Thomas, Daniel; Meyer, Carsten; Linhart, Markus; Bitaraf, Sascha; Litt, Harold; Schwab, Jörg Otto; Schild, Hans; Sommer, Torsten

    2009-08-04

    Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).

  18. Characterization of the first RF coil dedicated to 1.5 T MR guided radiotherapy

    Science.gov (United States)

    Hoogcarspel, Stan J.; Zijlema, Stefan E.; Tijssen, Rob H. N.; Kerkmeijer, Linda G. W.; Jürgenliemk-Schulz, Ina M.; Lagendijk, Jan J. W.; Raaymakers, Bas W.

    2018-01-01

    The purpose of this study is to investigate the attenuation characteristics of a novel radiofrequency (RF) coil, which is the first coil that is solely dedicated to MR guided radiotherapy with a 1.5 T MR-linac. Additionally, we investigated the impact of the treatment beam on the MRI performance of this RF coil. First, the attenuation characteristics of the RF coil were characterized. Second, we investigated the impact of the treatment beam on the MRI performance of the RF coil. We additionally demonstrated the ability of the anterior coil to attenuate returning electrons and thereby reducing the dose to the skin at the distal side of the treatment beam. Intensity modulated radiation therapy simulation of a clinically viable treatment plan for spinal bone metastasis shows a decrease of the dose to the planned tumor volume of 1.8% as a result of the MR coil around the patient. Ionization chamber and film measurements show that the anterior and posterior coil attenuate the beam homogeneously by 0.4% and 2.2%, respectively. The impact of the radiation resulted in a slight drop of the time-course signal-to-noise ratio and was dependent on imaging parameters. However, we could not observe any image artifacts resulting from this irradiation in any situation. In conclusion, the investigated MR-coil can be utilized for treatments with the 1.5 T-linac system. However, there is still room for improvement when considering both the dosimetric and imaging performance of the coil.

  19. A comparison of fishery biology of jumbo flying squid,Dosidicus gigas outside three Exclusive Economic Zones in the Eastern Pacific Ocean

    Institute of Scientific and Technical Information of China (English)

    LIU Bilin; CHEN Xinjun; YI Qian

    2013-01-01

    Although many studies on the fishery biology of jumbo flying squid,Dosidicus gigas,have been conducted in the coastal areas within Exclusive Economic Zones (EEZs) of various countries due to its commercial and ecological importance,limited biological information is available from waters outside these EEZs.In this paper,we examined D.gigas fishery biology from waters outside Chilean,Peruvian and Costa Rican EEZs,based on the fishery data collected by Chinese jigging vessels during 2006 to 2010.The dominant mantle lengths of D.gigas were 350-450 mm,250-400 mm and 250-350 mm outside Chilean,Peruvian and Costa Rican EEZs,respectively.Size structure analysis show that a medium-sized group existed mostly in the waters outside the Chilean and Peruvian EEZs,whereas a small-sized group occurred mainly in the waters outside the Costa Rican EEZ.The longevity of the squid outside the Costa Rican EEZ was less than 10 months,while most of those outside Chilean and Peruvian EEZs were about 1-1.5 years and very few large individuals were 1.5-2 years old.A higher percentage of mature individuals existed outside Costa Rican EEZ implying the region as a potential spawning ground,while lower proportions of mature squid outside the Peruvian and Chilean EEZs indicated that spawning may be occurring outside our study area.Spatial differences in sizes at maturity of the squid are thought to be result from different environmental factors especially different temperature and nutrition among the three areas.Stomach-content analysis showed that cannibalism was important in the diet of D.gigas.Stress generated by jigging may increase the incidence of cannibalism.

  20. Spatial and trophic preferences of jumbo squid Dosidicus gigas (D´Orbigny, 1835) in the central Gulf of California: ecological inferences using stable isotopes.

    Science.gov (United States)

    Trasviña-Carrillo, L D; Hernández-Herrera, A; Torres-Rojas, Y E; Galván-Magaña, F; Sánchez-González, A; Aguíñiga-García, S

    2018-04-26

    The jumbo squid Dosidicus gigas is a fishery resource of considerable economic and ecological importance in the Mexican Pacific. Studies on its habitat preferences are needed to understand recent fluctuations in the species' abundance and availability. Stable isotope analysis allows us to infer ecological aspects such as spatial distribution and trophic preferences. We used an isotope ratio mass spectrometer, automated for carbonate analysis, and coupled to an elemental analyzer, to determine the isotopic composition of statoliths (δ 18 O and δ 13 C values) and beaks (δ 13 C and δ 15 N values) from 219 individuals caught over two fishing seasons (2007 and 2009) off the coast of Santa Rosalía, in the central Gulf of California. We used these isotopic ratios to assess variation in spatial and trophic preferences by sex, size, and fishing season. In the 2009 group, we observed significant differences in statolith δ 13 C values and beak δ 13 C and δ 15 N values between males and females. Between size groups, we observed significant differences in statolith δ 18 O and δ 13 C values in 2007 and in beak δ 13 C and δ 15 N values during both seasons. Both seasons were characterized by high overlap in δ 18 O and δ 13 C values between sexes and in 2009 between size groups. We observed low trophic overlap between sexes in 2009 and between size groups during both seasons. The isotopic ratios from statoliths and beaks indicate that D. gigas has changed its spatial and trophic preferences, a shift that is probably related to changes in the species diet. This intraspecific variation in preferences could be related to characteristics such as size, which may influence squid distribution preferences. This article is protected by copyright. All rights reserved.

  1. Intraindividual comparison of myocardial delayed enhancement MR imaging using gadobenate dimeglumine at 1.5 T and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, Bernhard D.; Seeger, Achim; Fenchel, Michael; Kramer, Ulrich; Claussen, Claus D.; Miller, Stephan [Eberhard Karls University Tuebingen, Department for Diagnostic Radiology, Tuebingen (Germany); Sandstede, Joern [Roentgenzentrum, Hamburg (Germany); Lodemann, Klaus P. [Bracco Altana Pharma, Konstanz (Germany); Hoevelborn, Tobias [Eberhard Karls University Tuebingen, Department for Cardiology, Tuebingen (Germany)

    2009-05-15

    For contrast-enhanced imaging techniques relying on strong T1 weighting, 3 T provides increased contrast compared with 1.5 T. The aim of our study was the intraindividual comparison of delayed enhancement MR imaging at 1.5 T and at 3 T. Twenty patients with myocardial infarction were examined at 1.5 T and 3 T. Fifteen minutes after injection of contrast agent (0.1 mmol gadobenate dimeglumine per kg body weight), inversion recovery gradient recalled echo (IR-GRE) sequences were acquired (1.5 T/3 T: TR 11.0/9.9 ms, TE 4.4/4.9 ms, flip 30 /30 , slice thickness 6/6 mm) to assess myocardial viability. Two observers rated image quality (Wilcoxon signed rank test). Quantification of hyperenhanced myocardium and standardized SNR/CNR measurements were performed (Student's t test). There was no significant difference with respect to image quality (1.5 T/3 T: 3.5/3.3, p = 0.34, reader 1; 2.4/2.7, p = 0.12, reader 2) and infarction size (760 {+-} 566/828 {+-} 677 mm{sup 2} at 1.5 T, 808 {+-} 639/826 {+-} 726 mm{sup 2} at 3 T, reader 1/reader 2, p > 0.05). Mean SNR in hyperenhanced/normal myocardium was 19.2/6.2 at 1.5 T and 29.5/8.8 at 3 T (p < 0.05). Mean CNR was 14.3 at 1.5 T and 26.0 at 3 T (p < 0.05). Delayed enhancement MR imaging at 3 T is a robust procedure yielding superior tissue contrast at 3 T compared with 1.5 T which is, however, not reflected by increased image quality. (orig.)

  2. Circulating CD4+CXCR5+ T cells contribute to proinflammatory responses in multiple ways in coronary artery disease.

    Science.gov (United States)

    Ding, Ru; Gao, Wenwu; He, Zhiqing; Wu, Feng; Chu, Yang; Wu, Jie; Ma, Lan; Liang, Chun

    2017-11-01

    Coronary artery disease (CAD) is a common subtype of cardiovascular disease. The major contributing event is atherosclerosis, which is a progressive inflammatory condition resulting in the thickening of the arterial wall and the formation of atheromatous plaques. Recent evidence suggests that circulating CD4 + CXCR5 + T cells can contribute to inflammatory reactions. In this study, the frequency, phenotype, and function of circulating CD4 + CXCR5 + T cells in CAD patients were examined. Data showed that circulating CD4 + CXCR5 + T cells in CAD patients were enriched with a PD-1 + CCR7 - subset, which was previously identified as the most potent in B cell help. The CD4 + CXCR5 + T cells in CAD patients also secreted significantly higher levels of IFN-γ, IL-17A, and IL-21 than those from healthy controls. Depleting the PD-1 + population significantly reduced the cytokine secretion. Interestingly, the CD4 + CXCR5 + PD-1 - T cells significantly upregulated PD-1 following anti-CD3/CD28 or SEB stimulation. CD4 + CXCR5 + T cells from CAD patients also demonstrated more potent capacity to stimulate B cell inflammation than those from healthy individuals. The phosphorylation of STAT1 and STAT3 were significantly higher in B cells incubated with CD4 + CXCR5 + T cells from CAD than controls. The IL-6 and IFN-γ expression were also significantly higher in B cells incubated with CD4 + CXCR5 + T cells from CAD. Together, this study demonstrated that CAD patients presented a highly activated CD4 + CXCR5 + T cell subset that could contribute to proinflammatory responses in multiple ways. The possibility of using CD4 + CXCR5 + T cells as a therapeutic target should therefore be examined in CAD patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Beam characterisation of the 1.5 T MRI-linac

    Science.gov (United States)

    Woodings, S. J.; Bluemink, J. J.; de Vries, J. H. W.; Niatsetski, Y.; van Veelen, B.; Schillings, J.; Kok, J. G. M.; Wolthaus, J. W. H.; Hackett, S. L.; van Asselen, B.; van Zijp, H. M.; Pencea, S.; Roberts, D. A.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-04-01

    As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta 3D scanning water phantom and a PTW 1D water phantom. EBT3 Gafchromic film and ion chamber measurements in a buildup cap were also used. Special consideration was given to scan offsets, detector effective points of measurement and avoiding air gaps. Machine performance has been verified and the system satisfied the relevant beam requirements of IEC60976. Beam data were acquired for field sizes between 1  ×  1 and 57  ×  22 cm2. New techniques were developed to measure percentage depth dose (PDD) curves including the electron return effect at beam exit, which exhibits an electron-type practical range of cm. The Lorentz force acting on the secondary charged particles creates an asymmetry in the crossline profiles with an average shift of  +0.24 cm. For a 10  ×  10 cm2 beam, scatter from the cryostat contributes 1% of the dose at isocentre. This affects the relative output factors, scatter factors and beam profiles, both in-field and out-of-field. The average 20%–80% penumbral width measured for small fields with a microDiamond detector at 10 cm depth is 0.50 cm. MRI-linac penumbral widths are very similar to that of the Elekta Agility linac MLC, as is the near-surface dose PDD(0.2 cm)  =  57%. The entrance surface dose is  ∼36% of . Cryostat transmission is quantified for inclusion within the treatment planning system. As a result, the 1.5 T MRI-linac 7 MV FFF beam has been characterised for the first time and is suitable for clinical use. This was a key step towards the first clinical treatments with the MRI-linac, which were delivered at University Medical Center Utrecht in May 2017

  4. MR imaging of intracerebral hemorrhage lesions: Comparison of 2.0 T and 0.5 T images

    International Nuclear Information System (INIS)

    Han, Moon Hee; Chang, Kee Hyun

    1990-01-01

    Seventeen patients with intracerebral hemorrhage lesions were examined with magnetic resonance imaging at both 2.0 T and 0.5 T, in order to evaluate the capability of detecting and characterizing the hemorrhagic lesions at each field strength and to compare the signal intensities of the hemorrhages between both field strengths. The intervals between two imagings were within 2 hours in all patients except for 4 patients with subacute hematoma and occult cerebrovascular malformations in whom the intervals were 1 to 4 days. At each field strength, both T1 and T2-weighted spin echo(SE) images were obtained in all patients. All the hemorrhagic lesions were readily detected and characterized as hemorrhagic lesions at 2.0 T, whereas one lesion of chronic hemorrhage was not detected, and three lesions(one acute hemorrhage, one chronic hemorrhage and one occult cerebrovascular malformation) could not be characterized as hemorrhagic lesions at 0.5 T. There were statistically significant differences in signal intensity of the hematomas between 2.0 T and 0.5 T on proton density-weighted and T2-weighted images in cases of acute intracerebral hematomas: the hematomas seen as low intensity at 2.0 T appeared iso-or slightly high at 0.5 T. In conclusion, the intracerebral hematomas may be difficult to detect and to characterize with SE technique at 0.5 T, and then the gradient echo technique may be useful at 0.5 T

  5. Abnormal differentiation, hyperplasia and embryonic/perinatal lethality in BK5-T/t transgenic mice

    Science.gov (United States)

    Chen, Xin; Schneider-Broussard, Robin; Hollowell, Debra; McArthur, Mark; Jeter, Collene R.; Benavides, Fernando; DiGiovanni, John; Tang, Dean G.

    2009-01-01

    The cell-of-origin has a great impact on the types of tumors that develop and the stem/progenitor cells have long been considered main targets of malignant transformation. The SV40 large T and small t antigens (T/t), have been targeted to multiple differentiated cellular compartments in transgenic mice. In most of these studies, transgenic animals develop tumors without apparent defects in animal development. In this study, we used the bovine keratin 5 (BK5) promoter to target the T/t antigens to stem/progenitor cell-containing cytokeratin 5 (CK5) cellular compartment. A transgene construct, BK5-T/t, was made and microinjected into the male pronucleus of FVB/N mouse oocytes. After implanting ∼1700 embryos, only 7 transgenics were obtained, including 4 embryos (E9.5, E13, E15, and E20) and 3 postnatal animals, which died at P1, P2, and P18, respectively. Immunohistological analysis revealed aberrant differentiation and prominent hyperplasia in several transgenic CK5 tissues, especially the upper digestive organs (tongue, oral mucosa, esophagus, and forestomach) and epidermis, the latter of which also showed focal dysplasia. Altogether, these results indicate that constitutive expression of the T/t antigens in CK5 cellular compartment results in abnormal epithelial differentiation and leads to embryonic/perinatal animal lethality. PMID:19272531

  6. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips

    Energy Technology Data Exchange (ETDEWEB)

    Roychowdhury, Anita [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States); Gubrud, M. A.; Dana, R.; Dreyer, M. [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Anderson, J. R.; Lobb, C. J.; Wellstood, F. C. [Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States)

    2014-04-15

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of Cu{sub x}Bi{sub 2}Se{sub 3}. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  7. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips.

    Science.gov (United States)

    Roychowdhury, Anita; Gubrud, M A; Dana, R; Anderson, J R; Lobb, C J; Wellstood, F C; Dreyer, M

    2014-04-01

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of CuxBi2Se3. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  8. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  9. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D. [Institute for Cancer Research and Treatment (IRCC), Candiolo, Torino (Italy)

    2012-05-15

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  10. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    International Nuclear Information System (INIS)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D.

    2012-01-01

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  11. Comparison of MR sequences in early cerebral infarction at 0.5 T

    International Nuclear Information System (INIS)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A.

    2000-01-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested

  12. Appearance of normal brain maturation on 1.5-T MR images

    International Nuclear Information System (INIS)

    Barkovich, A.J.; Kjos, B.; Jackson, D.E. Jr.; Norman, D.

    1987-01-01

    To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of myelination, as demonstrated by histochemical methods. T1-weighted images were most useful to monitor normal brain development in the first 6 to 8 months of life; T2-weighted images were more useful after 6 months. The milestones in the MR appearance of normal maturation of the brain are presented. The milestones in the MR appearance of normal maturation of the brain are presented. Persistent areas of long T2 relaxation times are seen superior and dorsal to the ventricular trigone in all infants examined and should not be mistaken for ischemic change

  13. Comparison of MR sequences in early cerebral infarction at 0.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A. [Hacettepe Univ. Hospital, Ankara (Turkey). Radiology Dept.

    2000-11-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested.

  14. Angiographically occult vascular malformation of the brain: MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Patel, S.C.; Sanders, W.P.; Fuentes, J.; Haggar, A.M.; Mehta, B.A.; Boulos, R.S.; Froelich, J.W.

    1986-01-01

    MR imaging was performed in nine patients with 12 angiographically occult arteriovenous malformations using a 1.5-T superconducting magnet; four additional patients were imaged using a 0.3-T system. All images were reviewed in conjunction with CT scans. The following observations were made. (1) Eleven of 14 supratentorial lesions were located at the junction of gray and white matter. (2) Exclusing acute hemorrhage, only two lesions displayed mild mass effect. (3) All lesions displayed central foci of high signal intensity, probably representing subacute hemorrhage. (4) All lesions but one showed a peripheral rim of low signal intensity which progressively lost signal with increasing T2 weighting. This most likely represents iron-containing hemosiderin deposition. (5) Lesions were best demonstrated with long repetition times and moderate T2 weighting (TR = 2,500 msec, TE = 25-100 msec). (6) All lesions but one were hyperdense on non-contrast-enhanced CT, although only three had unequivocal calcification. The possibility of hyperdensity due to blood or iron deposition is discussed

  15. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  16. Comparative study of electrochemical oxidation of herbicide 2,4,5-T: Kinetics, parametric optimization and mineralization pathway

    Directory of Open Access Journals (Sweden)

    Hicham Zazou

    2017-01-01

    Full Text Available Oxidative degradation of herbicide 2,4,5-T was studied by electrochemical advanced oxidation processes anodic oxidation and electro-Fenton (EF using Pt/carbon felt and BDD/carbon felt cells. The effect of main operating parameters on oxidation of 2,4,5-T and mineralization of its aqueous solution were investigated. The rate constant for oxidation of 2,4,5-T by ·≡OH was determined as (3.7 ± 0.2 × 109 M−1 s−1 using competition kinetics method. The EF process with BDD anode was shown to be very efficient reaching 94% mineralization in 3 h treatment. Based on identified aromatic intermediates, short-chain carboxylic acids, released inorganic ions and total organic carbon removal measurements, a plausible oxidation pathway for mineralization of 2,4,5-T by hydroxyl radical was proposed. In addition, the evolution of solution toxicity during treatment was monitored by Microtox method showing the formation of toxic aromatic/cyclic intermediates. The results showed also that EF process was able to remove efficiently toxic intermediates and consequently solution toxicity.

  17. 26 CFR 1.512(a)-5T - Questions and answers relating to the unrelated business taxable income of organizations...

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Questions and answers relating to the unrelated... TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.512(a)-5T Questions and answers relating to the unrelated business taxable...

  18. Qualitative and quantitative assessments of knee magnetic resonance imaging: Comparison with 1.5T and 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Eun Hoe [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of)

    2016-11-15

    This study aims to conduct an analysis in order to compare the differences in the generation of artifacts occurring due to the difference between 1.5 T and 3.0 T MRI equipment with three types of pulse sequence applied to the knee MRI. with data on 121 patients transmitted to PACS, this study qualitatively analyzed SNRs and carried out a qualitative evaluation, dividing AC, ACL and PCL into three steps. In the quantitative analysis, The SNRs of 3.0 T MRI showed a more significant result, which was higher than that measured in the 1.5 T MRI (p<0.05). In the qualitative analysis, also showed similar to results when compared with 1.5 T (p<0.05). In conclusion, the increased signal to noise ratio at 3.0 T resulted in a better visibility of the majority of AC, ACL, PCL structures as compared to 1.5 T equipment. This study will become the guidelines for musculoskeletal system when examining the patients in knee MRI using the two types of equipment in the clinical setting in the future.

  19. Application of Quantitative MRI for Brain Tissue Segmentation at 1.5 T and 3.0 T Field Strengths

    Science.gov (United States)

    West, Janne; Blystad, Ida; Engström, Maria; Warntjes, Jan B. M.; Lundberg, Peter

    2013-01-01

    Background Brain tissue segmentation of white matter (WM), grey matter (GM), and cerebrospinal fluid (CSF) are important in neuroradiological applications. Quantitative Mri (qMRI) allows segmentation based on physical tissue properties, and the dependencies on MR scanner settings are removed. Brain tissue groups into clusters in the three dimensional space formed by the qMRI parameters R1, R2 and PD, and partial volume voxels are intermediate in this space. The qMRI parameters, however, depend on the main magnetic field strength. Therefore, longitudinal studies can be seriously limited by system upgrades. The aim of this work was to apply one recently described brain tissue segmentation method, based on qMRI, at both 1.5 T and 3.0 T field strengths, and to investigate similarities and differences. Methods In vivo qMRI measurements were performed on 10 healthy subjects using both 1.5 T and 3.0 T MR scanners. The brain tissue segmentation method was applied for both 1.5 T and 3.0 T and volumes of WM, GM, CSF and brain parenchymal fraction (BPF) were calculated on both field strengths. Repeatability was calculated for each scanner and a General Linear Model was used to examine the effect of field strength. Voxel-wise t-tests were also performed to evaluate regional differences. Results Statistically significant differences were found between 1.5 T and 3.0 T for WM, GM, CSF and BPF (p3.0 T. The mean differences between 1.5 T and 3.0 T were -66 mL WM, 40 mL GM, 29 mL CSF and -1.99% BPF. Voxel-wise t-tests revealed regional differences of WM and GM in deep brain structures, cerebellum and brain stem. Conclusions Most of the brain was identically classified at the two field strengths, although some regional differences were observed. PMID:24066153

  20. Quantitative susceptibility mapping across two clinical field strengths: Contrast-to-noise ratio enhancement at 1.5T.

    Science.gov (United States)

    Ippoliti, Matteo; Adams, Lisa C; Winfried, Brenner; Hamm, Bernd; Spincemaille, Pascal; Wang, Yi; Makowski, Marcus R

    2018-04-16

    Quantitative susceptibility mapping (QSM) is an MRI postprocessing technique that allows quantification of the spatial distribution of tissue magnetic susceptibility in vivo. Contributing sources include iron, blood products, calcium, myelin, and lipid content. To evaluate the reproducibility and consistency of QSM across clinical field strengths of 1.5T and 3T and to optimize the contrast-to-noise ratio (CNR) at 1.5T through bandwidth tuning. Prospective. Sixteen healthy volunteers (10 men, 6 women; age range 24-37; mean age 27.8 ± 3.2 years). 1.5T and 3T systems from the same vendor. Four spoiled gradient echo (SPGR) sequences were designed with different acquisition bandwidths. QSM reconstruction was achieved through a nonlinear morphology-enabled dipole inversion (MEDI) algorithm employing L1 regularization. CNR was calculated in seven regions of interest (ROIs), while reproducibility and consistency of QSM measurements were evaluated through voxel-based and region-specific linear correlation analyses and Bland-Altman plots. Interclass correlation, Wilcoxon rank sum test, linear regression analysis, Bland-Altman analysis, Welch's t-test. CNR analysis showed a statistically significant (P limits of agreement from -18.7 to 25.8 ppb) in the ROI-based analysis, while the correlation was found to be good for the voxel-based analysis of averaged maps (R ≥ 0.90, widest limits of agreement from -9.3 to 9.1 ppb). CNR of QSM images reconstructed from 1.5T acquisitions can be enhanced through bandwidth tuning. MEDI-based QSM reconstruction demonstrated to be reproducible and consistent both across field strengths (1.5T and 3T) and bandwidth variation. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  1. The breast cancer antigen 5T4 interacts with Rab11, and is a target and regulator of Rab11 mediated trafficking.

    Science.gov (United States)

    Harris, Janelle L; Dave, Keyur; Gorman, Jeffrey; Khanna, Kum Kum

    2018-06-01

    5T4 is a transmembrane glycoprotein with limited expression in normal adult tissues and expression in some solid tumours. It is unclear whether 5T4 is preferentially expressed by stem or differentiated cell types. Modes of 5T4 regulation are unknown despite its ongoing development as a cancer immunotherapy target. Our aims were to clarify the differentiation status of 5T4 expressing cells in breast cancer and to understand the mechanism underlying 5T4 membrane presentation. We analysed 5T4 expression in breast cancer cell populations by flow cytometery and found that 5T4 is highly expressed on differentiated cells, where it localizes to focal adhesions. Using immunoprecipitation and mass spectrometry, we identified interactions between 5T4 and the membrane trafficking proteins Rab11, Rab18 and ARF6. Mechanistically we found that Rab11 and Rab18 have oppositional roles in controlling expression and surface presentation of 5T4. 5T4 depletion stabilizes Rab11 protein expression with a consequent stimulation transferrin surface labelling, indicating that 5T4 represses endocytic activity. Successful immunotherapeutic targeting of 5T4 requires surface presentation and different immunotherapy strategies require surface presentation versus endocytosis. While breast cancer cells with high 5T4 surface expression and rapid cell surface turnover would be susceptible to antibody-drug conjugates that rely on intracellular release, 5T4 positive cells with lower expression or lower turnover may still be responsive to T-cell mediated approaches. We find that endocytosis of 5T4 is strongly Rab11 dependent and as such Rab11 activity could affect the success or failure of 5T4-targetted immunotherapy, particularly for antibody-drug conjugate approaches. In fact, 5T4 itself represses Rab11 expression. This newly uncovered relationship between Rab11 and 5T4 suggests that breast tumours with high 5T4 expression may not have efficient endocytic uptake of 5T4-targetted immunotherapeutics

  2. MR diagnosis of bone metastases at 1.5 T and 3 T. Can STIR imaging be omitted?

    Energy Technology Data Exchange (ETDEWEB)

    Ohlmann-Knafo, S.; Tarnoki, A.D.; Tarnoki, D.L.; Pickuth, D. [Caritasklinikum Saarbruecken St. Theresia (Germany). Dept. of Diagnostic and Interventional Radiology

    2015-10-15

    To date, no prospective comparative study of the diagnostic value of STIR versus T1-weighted (T1w) sequences at both 1.5 T and 3 T has been performed with special focus on the detectability of bone metastases. 212 oncological patients had a whole-body MRI at 1.5 T and/or at 3 T. The standard protocol comprised STIR and T1w sequences. All patients who showed typical signs of bone metastases were included in the study. Evaluation of the images was performed by the calculation of the number of metastases by three independent readers and by visual assessment on a 4-point scale. 86 patients fulfilled the inclusion criteria. The total number of metastases was significantly higher on T1w than on STIR images at both field strengths (p < 0.05). T1w revealed a sensitivity of 99.72 % (3 T) and 100.00 % (1.5 T) versus STIR with 70.99 % (3 T) and 79.34 % (1.5 T). In 53 % (38/72) of all patients, STIR detected fewer bone metastases in comparison with T1w at 3 T. At 1.5 T, STIR showed inferior results in 37.5 % (18/48) of all patients. Qualitative analysis indicated a significantly better lesion conspicuity, lesion delineation and an improved image quality on T1w compared to STIR imaging at both field strengths (p < 0.05) with similar results for T1w at 1.5 T and 3 T, but inferior results for STIR especially at 3 T. The whole-body MRI protocol for the detection of bone metastases could safely be limited to the T1w sequence in adults, especially at 3 T. There is no need for an additional STIR sequence. These initial results will have a major impact on the department's workflow if confirmed by larger studies as they will help reduce examination time and therefore save financial resources.

  3. Cellular Imaging at 1.5 T: Detecting Cells in Neuroinflammation using Active Labeling with Superparamagnetic Iron Oxide

    Directory of Open Access Journals (Sweden)

    Ayman J. Oweida

    2004-04-01

    Full Text Available The ability to visualize cell infiltration in experimental autoimmune encephalomyelitis (EAE, a well-known animal model for multiple sclerosis in humans, was investigated using a clinical 1.5-T magnetic resonance imaging (MRI scanner, a custom-built, high-strength gradient coil insert, a 3-D fast imaging employing steady-state acquisition (FIESTA imaging sequence and a superparamagnetic iron oxide (SPIO contrast agent. An “active labeling” approach was used with SPIO administered intravenously during inflammation in EAE. Our results show that small, discrete regions of signal void corresponding to iron accumulation in EAE brain can be detected using FIESTA at 1.5 T. This work provides early evidence that cellular abnormalities that are the basis of diseases can be probed using cellular MRI and supports our earlier work which indicates that tracking of iron-labeled cells will be possible using clinical MR scanners.

  4. Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI.

    Science.gov (United States)

    Nguyen, Dang Khoa; Rochette, Emilie; Leroux, Jean-Maxime; Beaudoin, Gilles; Cossette, Patrick; Lassonde, Maryse; Guilbert, François

    2010-10-01

    High-field 3.0 T MR scanners provide an improved signal-to-noise ratio which can be translated in higher image resolution, possibly allowing critical detection of subtle epileptogenic lesions missed on standard-field 1.0-1.5 T MRIs. In this study, the authors explore the potential value of re-imaging at 3.0 T patients with refractory partial epilepsy and negative 1.5 T MRI. We retrospectively identified all patients with refractory partial epilepsy candidate for surgery who had undergone a 3.0 T MR study after a negative 1.5 T MR study. High-field 3.0 T MRIs were reviewed qualitatively by neuroradiologists experienced in interpreting epilepsy studies with access to clinical information. Relevance and impact on clinical management were assessed by an epileptologist. Between November 2006 and August 2009, 36 patients with refractory partial epilepsy candidate for surgery underwent 3.0 T MR study after a 1.5 T MR study failed to disclose a relevant epileptogenic lesion. A potential lesion was found only in two patients (5.6%, 95% CI: 1.5-18.1%). Both were found to have hippocampal atrophy congruent with other presurgical localization techniques which resulted in omission of an invasive EEG study and direct passage to surgery. The frequency of detection of a new lesion by re-imaging at 3.0 T patients with refractory partial epilepsy candidate for surgery was found to be low, but seems to offer the potential of a significant clinical impact for selected patients. This finding needs to be validated in a prospective controlled study. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  5. Comparative study of imaging at 3.0 T versus 1.5 T of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Scott [University of California, San Francisco, Department of Radiology, San Francisco, CA (United States); University of Miami Miller School of Medicine, Miami, FL (United States); Steinbach, Lynne; Zhao, Jian; Link, Thomas M. [University of California, Department of Radiology, San Francisco, CA (United States); Stehling, Christoph [University of California, Department of Radiology, San Francisco, CA (United States); University of Muenster, Department of Radiology, Muenster (Germany); Ma, C.B. [University of California San Francisco, Department of Orthopedic Surgery, San Francisco, CA (United States)

    2009-08-15

    The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student's t tests with a significance threshold of p<0.05. Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p<0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p<0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee. (orig.)

  6. High-field (1.5 T) MR imaging of insults to the central nervous system in neonates and infants

    International Nuclear Information System (INIS)

    Nowell, M.A.; Zimmerman, R.A.; Hackney, D.B.; Bilaniuk, L.T.; Grossman, R.I.; Goldberg, H.I.

    1986-01-01

    One hundred neonates and infants less than 2 years old (50% < 6 months old) were imaged using a 1.5-T magnet. For 80% of the patients CT and/or US correlation of MR findings was available. Neonatal tumors, intraventricular hemorrhage, superior sagittal sinus thrombosis, seizure disorder, and patterns of normal and abnormal myelination were some of the clinical conditions examined. Imaging technique, neonatal monitoring concerns, and other practical considerations are addressed

  7. Comparative study of imaging at 3.0 T versus 1.5 T of the knee

    International Nuclear Information System (INIS)

    Wong, Scott; Steinbach, Lynne; Zhao, Jian; Link, Thomas M.; Stehling, Christoph; Ma, C.B.

    2009-01-01

    The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student's t tests with a significance threshold of p<0.05. Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p<0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p<0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee. (orig.)

  8. Workflow efficiency of two 1.5 T MR scanners with and without an automated user interface for head examinations.

    Science.gov (United States)

    Moenninghoff, Christoph; Umutlu, Lale; Kloeters, Christian; Ringelstein, Adrian; Ladd, Mark E; Sombetzki, Antje; Lauenstein, Thomas C; Forsting, Michael; Schlamann, Marc

    2013-06-01

    Workflow efficiency and workload of radiological technologists (RTs) were compared in head examinations performed with two 1.5 T magnetic resonance (MR) scanners equipped with or without an automated user interface called "day optimizing throughput" (Dot) workflow engine. Thirty-four patients with known intracranial pathology were examined with a 1.5 T MR scanner with Dot workflow engine (Siemens MAGNETOM Aera) and with a 1.5 T MR scanner with conventional user interface (Siemens MAGNETOM Avanto) using four standardized examination protocols. The elapsed time for all necessary work steps, which were performed by 11 RTs within the total examination time, was compared for each examination at both MR scanners. The RTs evaluated the user-friendliness of both scanners by a questionnaire. Normality of distribution was checked for all continuous variables by use of the Shapiro-Wilk test. Normally distributed variables were analyzed by Student's paired t-test, otherwise Wilcoxon signed-rank test was used to compare means. Total examination time of MR examinations performed with Dot engine was reduced from 24:53 to 20:01 minutes (P user interface (P = .001). According to this preliminary study, the Dot workflow engine is a time-saving user assistance software, which decreases the RTs' effort significantly and may help to automate neuroradiological examinations for a higher workflow efficiency. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  9. In vivo (1)H magnetic resonance spectroscopy of amniotic fluid and fetal lung at 1.5 T: technical challenges.

    Science.gov (United States)

    Kim, Dong-Hyun; Vahidi, Kiarash; Caughey, Aaron B; Coakley, Fergus V; Vigneron, Daniel B; Kurhanewicz, John; Mow, Ben; Joe, Bonnie N

    2008-10-01

    To identify the major technical challenges associated with in utero single-voxel proton spectroscopy of amniotic fluid and fetal lung and to evaluate the feasibility of performing in utero fetal spectroscopy for fetal lung maturity testing. Fetal magnetic resonance (MR) spectroscopy of amniotic fluid and fetal lung were performed at 1.5 T in 8 near-term pregnant women. Presence/absence of lactate and choline peaks was tabulated. Ex vivo spectra were obtained from amniotic fluid samples to investigate and refine sequence parameters. Spectroscopy failed in 3 of 8 cases due to maternal discomfort (n = 1) or fetal gastroschisis (n = 2). Both fetal motion and low signal-to-noise ratio were limiting factors for the remaining 5 clinical in vivo studies at 1.5 T. Ex vivo and in vivo studies suggested feasibility for detecting lactate from amniotic fluid within a reasonable clinical scan time (4-5 minutes). Lactate was detected in 3 of 5 patients. Choline detection was limited and was detected in 1 patient. Minor motion effects can be overcome but continuous fetal motion is problematic. Lactate detection seems clinically feasible, but choline detection requires additional technical development and, potentially, further imaging at a higher field strength because of the low signal-to-noise ratio at 1.5 T. (c) 2008 Wiley-Liss, Inc.

  10. Time-division polynomial pre-distorter for linearisation of 1.5 T MRI power amplifier

    Directory of Open Access Journals (Sweden)

    Ming Hui

    2017-06-01

    Full Text Available A time-division polynomial (TDP model is proposed for modelling and linearising a 1.5 T magnetic resonance imaging (MRI power amplifier (PA with strong non-linearity in high input signal dynamic range. In order to demonstrate the merit of this non-linear model, a 64 dBm 1.5 T MRI PA (63.89 MHz and two different Sinc-pulse signals are used in modelling and linearisation measurements. The TDP is compared with the conventional non-memory polynomial (NMP and no digital pre-distortion for the 1.5 T MRI PA, which is driven by test signal with 2 ms time length and 2% duty cycle. The proposed TDP leads to up to 9 dB improvement in the normalised mean square error compared with the NMP in two different test signals. More importantly, TDP illustrates significantly better reduction in amplitude modulation/amplitude modulation (AM/AM and amplitude modulation/phase modulation (AM/PM conversion compared with the NMP.

  11. Funtional MRI of cerebral motor cortex: comparison between 1.0 T and 1.5 T

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Yu, In Kyu; Song, In Chan; Han, Moon Hee; Lee, Heung Kyu; Chang, Kee Hyun

    1997-01-01

    To evaluate the feasibility of functional MR imaging(fMRI) with a 1.0 T scanner, fMRI of normal cerebral motor cortex at 1.0 T was compared with that at 1.5 T. FMRI of bilateral cerebral motor cortices (left, seven; right, six) was performed in seven healthy male volunteers aged 26-34 (mean 29) years,with BOLD contrast at both 1.0 T and 1.5 T units(Siemens MR scanners). Using both these systems,two-dimensional(2D) FLASH images were obtained with TR/TE of 90/56, flip angle of 40 deg, matrix size 128 * 128, slice thickness of 5mm, and FOV 23cm. A sequence consisting of five-image-off phase(rest phase) followed by five-image-on phase(activation with finger movement) was repeated four times without pause at a single plane. The same study was perfomed for the contralateral motor cortex in each volunteer. Using the z-test, activation images were obtained for the signal difference between on-and off-phases (p<0.05) and were then superimposed on 2D FLASH anatomic images at the same plane. Percentage changes of signal intensities(PCSIs) and numbers of activated pixels were compared, using the non-paramatric t-test, and periodicity of signal changes was compared, using the Mentel-Haenszel Chi-square test. Mean PCSIs at 1.5 T and 1.0 T in the left motor cortex were 3.13 ±1.20% and 1.43±0.56%, respectively(p=0.009),and in the right, 1.78±0.95% and 1.34±0.28%, respectively(p=0.32). The mean number of activated pixels at 1.5 T and 1.0 T in the left cortex was 21.14±10.67 and 19.86±11.36, respectively (p=0.83), and in the right, 22.5±6.47 and 16.8±8.47, respectively (p=0.22). At 1.5 T, periodicity of signal changes was seen in the left cortex in six of seven volunteers, and in the right cortex, in four of six. At 1.0 T, all showed periodicity (left:p=0.32;right:p=0.14). PCSIs in the dominant hemispheres were significantly higher at 1.5 T, but no other indicators showed significant differences between 1.0 T and 1.5 T. Acceptable fMRI can therefore be carried out with a 1

  12. Comparison of 1.5T and 3T 1H MR Spectroscopy for Human Brain Tumors

    International Nuclear Information System (INIS)

    Kim, Ji hoon; Chang, Kee Hyun; Na, Dong Gyu; Song, In Chan; Kim, Seung Ja; Kwon, Bae Ju; Han, Moon Hee

    2006-01-01

    We wanted to estimate the practical improvements of 3T proton MR spectroscopy (1H MRS) as compared with 1.5T 1H MRS for the evaluation of human brain tumors. Single voxel 1H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the 1H MRS spectra were obtained with a short echo time (TE) (35 msec) and an intermediate TE (144 msec) with the voxel size ranging from 2.0 cm 3 to 8.7 cm 3 . The signal to noise ratios (SNRs) of the metabolites (myoinositol [MI], choline compounds [Cho], creatine /phosphocreatine [Cr], N-acetyl-aspartate [NAA], lipid and lactate [LL]) and the metabolite ratios of MI/Cr, Cho/Cr, Cho/NAA and LL/Cr were compared at both TEs between the two field strengths in each brain tumor. The degrees 70f spectral resolution between the Cho and Cr peaks were qualitatively compared between the two field strengths in each brain tumor. The SNRs of the metabolites at 3T demonstrated 49-73% increase at a short TE (p 0.05) compared with those of 1.5T. The SNR of inverted lactate at an intermediate TE decreased down to 49% with poorer inversion at 3T (p 1 H MRS demonstrated 49-73% SNR increase in the cerebral metabolites and slightly superior spectral resolution only at a short TE, but little at an intermediate TE, in the brain tumors. There was no significant difference in the metabolite ratios between the two field strengths

  13. MRI evaluation of the anterolateral ligament of the knee: assessment in routine 1.5-T scans

    International Nuclear Information System (INIS)

    Partezani Helito, Camilo; Pecora, Jose Ricardo; Camanho, Gilberto Luis; Kawamura Demange, Marco; Partezani Helito, Paulo Victor; Pereira Costa, Hugo; Bordalo-Rodrigues, Marcelo

    2014-01-01

    This study evaluated the ability of routine 1.5-T MRI scans to visualize the anterolateral ligament (ALL) and describe its path and anatomic relations with lateral knee structures. Thirty-nine 1.5-T MRI scans of the knee were evaluated. The scans included an MRI knee protocol with T1-weighted sequences, T2-weighted sequences with fat saturation, and proton density (PD)-weighted fast spin-echo sequences. Two radiologists separately reviewed all MRI scans to evaluate interobserver reliability. The ALL was divided into three portions for analyses: femoral, meniscal, and tibial. The path of the ALL was evaluated with regard to known structural parameters previously studied in this region. At least a portion of the ALL was visualized in 38 (97.8 %) cases. The meniscal portion was most visualized (94.8 %), followed by the femoral (89.7 %) and the tibial (79.4 %) portions. The three portions of the ALL were visualized in 28 (71.7 %) patients. The ALL was characterized with greater clarity on the coronal plane and was visualized as a thin, linear structure. The T1-weighted sequences showed a statistically inferior ligament visibility frequency. With regard to the T2 and PD evaluations, although the visualization frequency in PD was higher for the three portions of the ligament, only the femoral portion showed significant values. The ALL can be visualized in routine 1.5-T MRI scans. Although some of the ligament could be depicted in nearly all of the scans (97.4 %), it could only be observed in its entirety in about 71.7 % of the tests. (orig.)

  14. MRI evaluation of the anterolateral ligament of the knee: assessment in routine 1.5-T scans

    Energy Technology Data Exchange (ETDEWEB)

    Partezani Helito, Camilo; Pecora, Jose Ricardo; Camanho, Gilberto Luis; Kawamura Demange, Marco [University of Sao Paulo, Faculty of Medicine, Institute of Orthopedics and Traumatology, Knee Surgery Division, Sao Paulo (Brazil); Partezani Helito, Paulo Victor; Pereira Costa, Hugo; Bordalo-Rodrigues, Marcelo [University of Sao Paulo, Faculty of Medicine, Institute of Orthopedics and Traumatology, Musculoskeletal Radiology Department, Sao Paulo (Brazil)

    2014-10-15

    This study evaluated the ability of routine 1.5-T MRI scans to visualize the anterolateral ligament (ALL) and describe its path and anatomic relations with lateral knee structures. Thirty-nine 1.5-T MRI scans of the knee were evaluated. The scans included an MRI knee protocol with T1-weighted sequences, T2-weighted sequences with fat saturation, and proton density (PD)-weighted fast spin-echo sequences. Two radiologists separately reviewed all MRI scans to evaluate interobserver reliability. The ALL was divided into three portions for analyses: femoral, meniscal, and tibial. The path of the ALL was evaluated with regard to known structural parameters previously studied in this region. At least a portion of the ALL was visualized in 38 (97.8 %) cases. The meniscal portion was most visualized (94.8 %), followed by the femoral (89.7 %) and the tibial (79.4 %) portions. The three portions of the ALL were visualized in 28 (71.7 %) patients. The ALL was characterized with greater clarity on the coronal plane and was visualized as a thin, linear structure. The T1-weighted sequences showed a statistically inferior ligament visibility frequency. With regard to the T2 and PD evaluations, although the visualization frequency in PD was higher for the three portions of the ligament, only the femoral portion showed significant values. The ALL can be visualized in routine 1.5-T MRI scans. Although some of the ligament could be depicted in nearly all of the scans (97.4 %), it could only be observed in its entirety in about 71.7 % of the tests. (orig.)

  15. Comparing 3 T and 1.5 T MRI for tracking Alzheimer's disease progression with tensor-based morphometry.

    Science.gov (United States)

    Ho, April J; Hua, Xue; Lee, Suh; Leow, Alex D; Yanovsky, Igor; Gutman, Boris; Dinov, Ivo D; Leporé, Natasha; Stein, Jason L; Toga, Arthur W; Jack, Clifford R; Bernstein, Matt A; Reiman, Eric M; Harvey, Danielle J; Kornak, John; Schuff, Norbert; Alexander, Gene E; Weiner, Michael W; Thompson, Paul M

    2010-04-01

    A key question in designing MRI-based clinical trials is how the main magnetic field strength of the scanner affects the power to detect disease effects. In 110 subjects scanned longitudinally at both 3.0 and 1.5 T, including 24 patients with Alzheimer's Disease (AD) [74.8 +/- 9.2 years, MMSE: 22.6 +/- 2.0 at baseline], 51 individuals with mild cognitive impairment (MCI) [74.1 +/- 8.0 years, MMSE: 26.6 +/- 2.0], and 35 controls [75.9 +/- 4.6 years, MMSE: 29.3 +/- 0.8], we assessed whether higher-field MR imaging offers higher or lower power to detect longitudinal changes in the brain, using tensor-based morphometry (TBM) to reveal the location of progressive atrophy. As expected, at both field strengths, progressive atrophy was widespread in AD and more spatially restricted in MCI. Power analysis revealed that, to detect a 25% slowing of atrophy (with 80% power), 37 AD and 108 MCI subjects would be needed at 1.5 T versus 49 AD and 166 MCI subjects at 3 T; however, the increased power at 1.5 T was not statistically significant (alpha = 0.05) either for TBM, or for SIENA, a related method for computing volume loss rates. Analysis of cumulative distribution functions and false discovery rates showed that, at both field strengths, temporal lobe atrophy rates were correlated with interval decline in Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog), mini-mental status exam (MMSE), and Clinical Dementia Rating sum-of-boxes (CDR-SB) scores. Overall, 1.5 and 3 T scans did not significantly differ in their power to detect neurodegenerative changes over a year. Hum Brain Mapp, 2010. (c) 2009 Wiley-Liss, Inc.

  16. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  17. Texture analysis in quantitative MR imaging. Tissue characterisation of normal brain and intracranial tumours at 1.5 T

    DEFF Research Database (Denmark)

    Kjaer, L; Ring, P; Thomsen, C

    1995-01-01

    The diagnostic potential of texture analysis in quantitative tissue characterisation by MR imaging at 1.5 T was evaluated in the brain of 6 healthy volunteers and in 88 patients with intracranial tumours. Texture images were computed from calculated T1 and T2 parameter images by applying groups o...... to be successful in some cases of clinical importance. However, no discrimination between benign and malignant tumour growth was possible. Much texture information seems to be contained in MR images, which may prove useful for classification and image segmentation....

  18. Optimization of the sequence parameter of multishot-EPI in 0.5T MRI to visualize cerebral microbleeds

    International Nuclear Information System (INIS)

    Kamiya, Naoki; Ito, Yoichi

    2007-01-01

    By using the gradient type multi-shot EPI method (MSEPI) which reflects the magnetic susceptibility effect more also with 0.5T MRI, it thought that improvement in detection ability of minute cerebral hemorrhage could be aimed at, and the optimal condition was examined. The phantom which put small air bubbles into the gel-like liquid was created, and a flip angle, echo time (TE), the number of shots, and the bandwidth were changed, it picked up, and the image pick-up conditions considered to be the optimal were determined. The vision evaluation in receiver operating characteristic (ROC) analysis was used for the determination of photography conditions. Photography conditions made flip angle=90 degree, TE=51 ms(the shortest value acquirable with a full echo),number of shots=8, and bandwidth=62.5 kHz. Next, phantom photography was carried out by the gradient echo method (GRE) which was being used conventionally and the MSEPI method, and vision evaluation in ROC analysis was performed. The MSEPI method (Az=0.978) and the GRE method (Az=0.950). Moreover, in Student's t test (p<0.05), the detection ability of the MSEPI method was high. By picking up by the MSEPI method also with 0.5T MRI, the detection ability of minute cerebral hemorrhage improved rather than the GRE method. (author)

  19. Gadoxate-enhanced T1-weighted MR cholangiography: comparison of 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, C.; Schima, W.; Weber, M.; Mang, T.; Nemec, S.; Kulinna-Cosentini, C.; Bastati, N.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2009-06-15

    Purpose: to qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5 T and 3.0 T. Materials and methods: a total of 40 patients with a non-dilated biliary system were retrospectively included in the study. T1-weighted MR cholangiography 20 min after IV administration of 0.025 mmol/kg gadoxate (Primovist trademark) was performed in 20 patients at 1.5 T and in another 20 patients at 3.0 T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct - LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: the CNRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0 T. Qualitative analysis showed a significant superiority for 3.0 T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). (orig.)

  20. A 1.5 T transverse magnetic field in radiotherapy of rectal cancer: Impact on the dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Uilkema, Sander, E-mail: s.uilkema@nki.nl; Heide, Uulke van der; Sonke, Jan-Jakob; Triest, Baukelien van; Nijkamp, Jasper [Department of Radiotherapy, NKI-AVL, Amsterdam 1066 CX (Netherlands); Moreau, Michel [RTP Research Group, Elekta, Maryland Heights, Missouri 63043 (United States)

    2015-12-15

    Purpose: MRI guidance during radiotherapy has the potential to enable more accurate dose delivery, optimizing the balance between local control and treatment related toxicity. However, the presence of a permanent magnetic field influences the dose delivery, especially around air cavities. Here, electrons are able to return to the surface through which they entered the air cavity (electron return effect, ERE) locally resulting in dose hot- and cold-spots. Where RT of rectal cancer patients might benefit from MRI guidance for margin reduction, air cavities in and around the target volume are frequently present. The purpose of this research is to evaluate the impact of the presence of a 1.5 T transverse magnetic field on dose delivery in patients with rectal cancer. Methods: Ten patients treated with 5 × 5 Gy RT having large changes in pelvic air content were selected out of a cohort of 33 patients. On the planning CT, a 1.5 T, 6 MV, 7-field intensity modulated radiotherapy (IMRT) plan was created. This plan was subsequently recalculated on daily CT scans. For each daily CT, the CTV V{sub 95%} and V{sub 107%} and bowel area V{sub 5Gy}, V{sub 10Gy}, V{sub 15Gy}, V{sub 20Gy}, and V{sub 25Gy} were calculated to evaluate the changes in dose distribution from fraction to fraction. For comparison, the authors repeated this procedure for the 0 T situation. To study the effect of changing air cavities separate from other anatomical changes, the authors also generated artificial air cavities in the CTV of one patient (2 and 5 cm diameter), in the high dose gradient region (2 cm), and in the low dose area (2 cm). Treatment plans were optimized without and with each simulated air cavity. For appearing and disappearing air cavities, the CTV V{sub 95%} and V{sub 107%} were evaluated. The authors also evaluated the ERE separate from attenuation changes locally around appearing gas pockets. Results: For the ten patients, at 1.5 T, the V{sub 95%} was influenced by both appearing and

  1. CLONING AND CHARACTERIZATION OF A CHROMOSOMAL DNA REGION REQUIRED FOR GROWTH ON 2,4,5-T BY PSEUDOMONAS CEPACIA AC1100

    Science.gov (United States)

    A series of spontaneous 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) nonmetabolizing mutants of Pseudomonas cepacia AC1100 were characterized to be defective in either 2,4,5-T uptake or conversion of this compound to 2,4,5-trichlorophenol (2,4,5-TCP). Two of these mutants, RHC22 a...

  2. SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Rubinstein, A; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at the center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.

  3. Performance of a PTW 60019 microDiamond detector in a 1.5 T MRI-linac

    Science.gov (United States)

    Woodings, S. J.; Wolthaus, J. W. H.; van Asselen, B.; de Vries, J. H. W.; Kok, J. G. M.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-03-01

    Accurate small-field dosimetry is critical for a magnetic resonance linac (MRI-linac). The PTW 60019 microDiamond is close to an ideal detector for small field dosimetry due to its small physical size, high signal-to-noise ratio and approximate water equivalence. It is important to fully characterise the performance of the detector in a 1.5 T magnetic field prior to its use for MRI-linac commissioning and quality assurance. Standard techniques of detector testing have been implemented, or adapted where necessary to suit the capabilities of the MRI-linac. Detector warmup, constancy, dose linearity, dose rate linearity, field size dependence and leakage were within tolerance. Measurements with the detector were consistent with ion chamber measurements for medium sized fields. The effective point of measurement of the detector when used within a 1.5 T magnetic field was determined to be 0.80 ± 0.23 mm below the top surface of the device, consistent with the existing vendor recommendation and alignment mark at 1.0 mm. The angular dependence was assessed. Variations of up to 9.7% were observed, which are significantly greater than in a 0 T environment. Within the expected range of use, the maximum effect is approximately 0.6% which is within tolerance. However for large beams within a magnetic field, the divergence and consequent variation in angle of photon incidence means that the microDiamond would not be ideal for characterising the profiles and it would not be suitable for determining large-field beam parameters such as symmetry. It would also require a correction factor prior to use for patient-specific QA measurements where radiation is delivered from different gantry angles. The results of this study demonstrate that the PTW 60019 microDiamond detector is suitable for measuring small radiation fields within a 1.5 T magnetic field and thus is suitable for use in MRI-linac commissioning and quality assurance.

  4. Technical Note: Dose effects of 1.5 T transverse magnetic field on tissue interfaces in MRI-guided radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xinfeng; Prior, Phil; Chen, Guang-Pei; Schultz, Christopher J.; Li, X. Allen, E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, Wisconsin 53226 (United States)

    2016-08-15

    Purpose: The integration of MRI with a linear accelerator (MR-linac) offers great potential for high-precision delivery of radiation therapy (RT). However, the electron deflection resulting from the presence of a transverse magnetic field (TMF) can affect the dose distribution, particularly the electron return effect (ERE) at tissue interfaces. The purpose of the study is to investigate the dose effects of ERE at air-tissue and lung-tissue interfaces during intensity-modulated radiation therapy (IMRT) planning. Methods: IMRT and volumetric modulated arc therapy (VMAT) plans for representative pancreas, lung, breast, and head and neck (HN) cases were generated following commonly used clinical dose volume (DV) criteria. In each case, three types of plans were generated: (1) the original plan generated without a TMF; (2) the reconstructed plan generated by recalculating the original plan with the presence of a TMF of 1.5 T (no optimization); and (3) the optimized plan generated by a full optimization with TMF = 1.5 T. These plans were compared using a variety of DV parameters, including V{sub 100%}, D{sub 95%}, DHI [dose heterogeneity index: (D{sub 20%}–D{sub 80%})/D{sub prescription}], D{sub max}, and D{sub 1cc} in OARs (organs at risk) and tissue interface. All the optimizations and calculations in this work were performed on static data. Results: The dose recalculation under TMF showed the presence of the 1.5 T TMF can slightly reduce V{sub 100%} and D{sub 95%} for PTV, with the differences being less than 4% for all but one lung case studied. The TMF results in considerable increases in D{sub max} and D{sub 1cc} on the skin in all cases, mostly between 10% and 35%. The changes in D{sub max} and D{sub 1cc} on air cavity walls are dependent upon site, geometry, and size, with changes ranging up to 15%. The VMAT plans lead to much smaller dose effects from ERE compared to fixed-beam IMRT in pancreas case. When the TMF is considered in the plan optimization, the

  5. Spin-echo and STIR MR imaging of sports-related muscle injuries at 1.5 T

    International Nuclear Information System (INIS)

    Greco, A.; McNamara, M.T.; Escher, R.M.B.; Trifilio, G.; Parienti, J.

    1990-01-01

    This paper assesses the value of T2-weighted and short T1 inversion recovery (Stir 1,800,170,27) sequences in the MR diagnosis and follow-up of muscle strain injuries. Fifty-six athletes with clinically diagnosed traumatic muscular damage were studied at 1.5 T with SE T1-weighted, double T2-weighted, and STIR techniques. Images were evaluated in order to detect the presence of muscle tear with associated edema, muscle hemorrhage (focal or diffuse), and perimuscular hemorrhage. The relative conspicuity of muscle injuries on T2-weighted and STIR images was assessed. All acute and subacute muscle injuries were detected on both SE T2-weighted and STIR images, muscle edema and subacute hemorrhage appearing hyperintense to normal muscle. Acute hemorrhage could appear hypointense on T2-weighted images but was always hyperintense on STIR images

  6. MR microscopy of articular cartilage at 1.5 T: orientation and site dependence of laminar structures

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi; Anno, Izumi; Echigo, Junko; Itai, Yuji [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575 (Japan); Haishi, Tomoyuki; Uematsu, Takaaki; Matsuda, Yoshimasa; Kose, Katsumi [Institute of Applied Physics, University of Tsukuba, Tsukuba (Japan); Lang, Philipp [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2002-09-01

    Abstract Objective. To evaluate MR microscopic images of normal-appearing porcine hyaline cartilage (n=15) in vitro obtained with an MR microscope using an independent console system (MRMICS) at 1.5 T.Design and results. The MRMICS is a portable imaging system consisting of a radiofrequency system, gradient power supplies and a personal computer. The images from the MRMICS showed a laminar structure of porcine cartilage similar to the structure demonstrated with other MR imaging techniques. The laminar structures of the articular cartilage, were, however heterogeneous in respect of signal intensity and thickness, which varied according to the site resected. The MR laminar appearance was most comparable to the staining with Masson's trichrome for collagen.Conclusion. MRMICS is a useful add-on system for obtaining microscopic MR images of articular cartilage in vitro. (orig.)

  7. An Influence of 7.5 T Superconducting Wiggler on Beam Parameters of Siberia-2 Storage Ring

    International Nuclear Information System (INIS)

    Korchuganov, Vladimir; Valentinov, Alexander; Mezentsev, Nikolai

    2007-01-01

    At present the dedicated synchrotron radiation source Siberia-2 in Kurchatov Institute operates with electron energy 2.5 GeV and current up to 200 mA. In order to expand spectral range of SR and to increase brightness an installation of 7.5 T 19-pole superconducting wiggler is planned at the end of 2006. Now the wiggler is under fabrication in BINP, Novosibirsk. Such high level of a magnetic field in the wiggler will have a great influence on electron beam parameters of Siberia-2. Changes of these parameters (betatron tunes, horizontal emittance of the electron beam, momentum compaction, energy spread etc.) are discussed in the report. Different methods of compensation (global and local) of betatron functions distortion are presented. Much attention is paid to dynamic aperture calculations using analytical approximation of magnetic field behavior in transverse horizontal direction

  8. Experimental study on the gasification characteristics of coal and orimulsion in 0.5 T/D gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ho Young; Kim, Jong Young; An, Dal Hong; Park, Tae Jun [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    For the construction of commercial plant for IGCC imported from aboard in near future, it is aimed to get gasification data, practice the gasification design capability, and develop a fundamental key technology through the experiments for different kinds of coals (Datong, Roto, Alaska) by 0.5 T/D gasifier. We performed the experiments for physical properties and reactivities on selected coals by means of Drop Tube Reactor, numerical analysis for the reactor. Throughout the characteristic studies of orimulsion gasification, feasibility studies for orimulsion gasification as a fuel for power plant be performed. With the six experiment runs for the coal gasifier, several problems were found to remedy. After remedies, the gasifier could run at good operating conditions maintaining with 200% design feed rate over 1200-1550 degree. The third and fourth gasification runs with Roto were satisfactorily completed, during which gross heating values from produced gas were 7200-8200 Kcal/Nm{sup 3}. (author). 118 refs., 145 figs.

  9. MR microscopy of articular cartilage at 1.5 T: orientation and site dependence of laminar structures

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Anno, Izumi; Echigo, Junko; Itai, Yuji; Haishi, Tomoyuki; Uematsu, Takaaki; Matsuda, Yoshimasa; Kose, Katsumi; Lang, Philipp

    2002-01-01

    Abstract Objective. To evaluate MR microscopic images of normal-appearing porcine hyaline cartilage (n=15) in vitro obtained with an MR microscope using an independent console system (MRMICS) at 1.5 T.Design and results. The MRMICS is a portable imaging system consisting of a radiofrequency system, gradient power supplies and a personal computer. The images from the MRMICS showed a laminar structure of porcine cartilage similar to the structure demonstrated with other MR imaging techniques. The laminar structures of the articular cartilage, were, however heterogeneous in respect of signal intensity and thickness, which varied according to the site resected. The MR laminar appearance was most comparable to the staining with Masson's trichrome for collagen.Conclusion. MRMICS is a useful add-on system for obtaining microscopic MR images of articular cartilage in vitro. (orig.)

  10. Experimental study on the gasification characteristics of coal and orimulsion in 0.5 T/D gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ho Young; Kim, Jong Young; An, Dal Hong; Park, Tae Jun [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1996-12-31

    For the construction of commercial plant for IGCC imported from aboard in near future, it is aimed to get gasification data, practice the gasification design capability, and develop a fundamental key technology through the experiments for different kinds of coals (Datong, Roto, Alaska) by 0.5 T/D gasifier. We performed the experiments for physical properties and reactivities on selected coals by means of Drop Tube Reactor, numerical analysis for the reactor. Throughout the characteristic studies of orimulsion gasification, feasibility studies for orimulsion gasification as a fuel for power plant be performed. With the six experiment runs for the coal gasifier, several problems were found to remedy. After remedies, the gasifier could run at good operating conditions maintaining with 200% design feed rate over 1200-1550 degree. The third and fourth gasification runs with Roto were satisfactorily completed, during which gross heating values from produced gas were 7200-8200 Kcal/Nm{sup 3}. (author). 118 refs., 145 figs.

  11. Effect of subcutaneous butylscopolamine administration in the reduction of peristaltic artifacts in 1.5-T MR fast abdominal examinations

    International Nuclear Information System (INIS)

    Dosda, Rosa; Marti-Bonmati, Luis; Molla, Enrique; Arana, Estanislao; Ronchera-Oms, Crisanto L.

    2003-01-01

    In abdominal MR imaging, ghost artifacts from noncyclic bowel movements can reduce the quality of the images. Although pharmacologic suppression of motion is effective, no study has being conducted to analyze the influence of drug motion suppression on fast breath-hold 1.5-T examinations of the upper abdomen. A prospective, randomized, double-blind trial was conducted in 50 patients. Patients were randomly distributed into two groups: The control group received only an oral solution, whereas the other group received the oral solution plus a subcutaneous injection of 20 mg of butylscopolamine 10 min before the MR examination. Breath-hold T1-weighted gradient-recalled-echo (GRE) MR images were obtained in a 1.5-T superconductive unit. Quantitative image analysis was performed with region-of-interest (ROI) measurements of the signal intensity of the liver and in background air anterior and lateral to the patient. A qualitative analysis of the subjective quality of the T1-weighted images was also done, and the adverse reactions were registered. The groups were homogeneous regarding age, gender, and weight distribution. No significant differences in the signal intensity of the liver and in the incoherent noise measurements were found between the two groups. Gastrointestinal noise showed significant differences between groups, with lower values for the butylscopolamine group compared with the control group. There was also a statistically significant difference in the image quality between groups, and optimal studies were only found in the butylscopolamine group, where most patients had a good-quality evaluation. Regarding adverse events, there were non-significant differences between groups. In conclusion, administration of an antiperistaltic agent to reduce the movements of the gastrointestinal tract diminishes the motion artifacts generated on MR imaging of the abdomen, even at high field strength and with fast imaging sequences. Images of the upper abdomen obtained

  12. Evaluation of pneumonia in children: comparison of MRI with fast imaging sequences at 1.5T with chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Yikilmaz, Ali; Koc, Ali; Coskun, Abdulhakim (Dept. of Radiology, Erciyes Medical School, Kayseri (Turkey)); Ozturk, Mustafa K (Dept. of Pediatric Infectious Diseases, Erciyes Medical School, Kayseri (Turkey)); Mulkern, Robert V; Lee, Edward Y (Dept. of Radiology and Dept. of Medicine, Pulmonary Div., Children' s Hospital Boston and Harvard Medical School, Boston (United States)), email: Edward.lee@childrens.harvard.edu

    2011-10-15

    Background Although there has been a study aimed at magnetic resonance imaging (MRI) evaluation of pneumonia in children at a low magnetic field (0.2T), there is no study which assessed the efficacy of MRI, particularly with fast imaging sequences at 1.5T, for evaluating pneumonia in children. Purpose To investigate the efficacy of chest MRI with fast imaging sequences at 1.5T for evaluating pneumonia in children by comparing MRI findings with those of chest radiographs. Material and Methods This was an Institutional Review Board-approved, HIPPA-compliant prospective study of 40 consecutive pediatric patients (24 boys, 16 girls; mean age 7.3 years +- 6.6 years) with pneumonia, who underwent PA and lateral chest radiographs followed by MRI within 24 h. All MRI studies were obtained in axial and coronal planes with two different fast imaging sequences: T1-weighted FFE (Fast Field Echo) (TR/TE: 83/4.6) and T2-weighted B-FFE M2D (Balanced Fast Field Echo Multiple 2D Dimensional) (TR/TE: 3.2/1.6). Two experienced pediatric radiologists reviewed each chest radiograph and MRI for the presence of consolidation, necrosis/abscess, bronchiectasis, and pleural effusion. Chest radiograph and MRI findings were compared with Kappa statistics. Results All consolidation, lung necrosis/abscess, bronchiectasis, and pleural effusion detected with chest radiographs were also detected with MRI. There was statistically substantial agreement between chest radiographs and MRI in detecting consolidation (k = 0.78) and bronchiectasis (k = 0.72) in children with pneumonia. The agreement between chest radiographs and MRI was moderate for detecting necrosis/abscess (k = 0.49) and fair for detecting pleural effusion (k = 0.30). Conclusion MRI with fast imaging sequences is comparable to chest radiographs for evaluating underlying pulmonary consolidation, bronchiectasis, necrosis/abscess, and pleural effusion often associated with pneumonia in children

  13. Specificity of choline metabolites for in vivo diagnosis of breast cancer using 1H MRS at 1.5 T

    International Nuclear Information System (INIS)

    Stanwell, Peter; Gluch, Laurence; Lean, Cynthia; Malycha, Peter; Mountford, Carolyn; Clark, David; Tomanek, Boguslaw; Baker, Luke; Giuffre, Bruno

    2005-01-01

    The purpose was to determine if in vivo proton magnetic resonance spectroscopy ( 1 H MRS) at 1.5 T can accurately provide the correct pathology of breast disease. Forty-three asymptomatic volunteers including three lactating mothers were examined and compared with 21 breast cancer patients. Examinations were undertaken at 1.5 T using a purpose-built transmit-receive single breast coil. Single voxel spectroscopy was undertaken using echo times of 135 and 350 ms. The broad composite resonance at 3.2 ppm, which includes contributions from choline, phosphocholine (PC), glycerophosphocholine (GPC), myo-inositol and taurine, was found not to be a unique marker for malignancy providing a diagnostic sensitivity and specificity of 80.0 and 86.0%, respectively. This was due to three of the asymptomatic volunteers and all of the lactating mothers also generating the broad composite resonance at 3.2 ppm. Optimised post-acquisitional processing of the spectra resolved a resonance at 3.22 ppm, consistent with PC, in patients with cancer. In contrast the spectra recorded for three false-positive volunteers, and the three lactating mothers had a resonance centred at 3.28 ppm (possibly taurine, myo-inositol or GPC). This improved the specificity of the test to 100%. Careful referencing of the spectra and post-acquisitional processing intended to optimise spectral resolution of in vivo MR proton spectra from human breast tissue resolves the composite choline resonance. This allows the distinction of patients with malignant disease from volunteers with a sensitivity of 80% and specificity of 100%. Therefore, resolution of the composite choline resonance into its constituent components improves the specificity of the in vivo 1 H MRS method, but does not overcome the problem of 20% false-negatives. (orig.)

  14. Functional MRI of the cervical spinal cord on 1.5 T with fingertapping: to what extent is it feasible?

    International Nuclear Information System (INIS)

    Govers, N.; Beghin, J.; Goethem, J.W.M. van; Hauwe, L. van den; Vandervliet, E.; Parizel, P.M.; Michiels, J.

    2007-01-01

    Until recently, functional magnetic resonance imaging (fMRI) with blood oxygen level-dependent (BOLD) contrast, was mainly used to study brain physiology. The activation signal measured with fMRI is based upon the changes in the concentration of deoxyhaemoglobin that arise from an increase in blood flow in the vicinity of neuronal firing. Technical limitations have impeded such research in the human cervical spinal cord. The purpose of this investigation was to determine whether a reliable fMRI signal can be elicited from the cervical spinal cord during fingertapping, a complex motor activity. Furthermore, we wanted to determine whether the fMRI signal could be spatially localized to the particular neuroanatomical location specific for this task. A group of 12 right-handed healthy volunteers performed the complex motor task of fingertapping with their right hand. T2*-weighted gradient-echo echo-planar imaging on a 1.5-T clinical unit was used to image the cervical spinal cord. Motion correction was applied. Cord activation was measured in the transverse imaging plane, between the spinal cord levels C5 and T1. In all subjects spinal cord responses were found, and in most of them on the left and the right side. The distribution of the activation response showed important variations between the subjects. While regions of activation were distributed throughout the spinal cord, concentrated activity was found at the anatomical location of expected motor innervation, namely nerve root C8, in 6 of the 12 subjects. fMRI of the human cervical spinal cord on an 1.5-T unit detects neuronal activity related to a complex motor task. The location of the neuronal activation (spinal cord segment C5 through T1 with a peak on C8) corresponds to the craniocaudal anatomical location of the neurons that activate the muscles in use. (orig.)

  15. Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners

    Science.gov (United States)

    Rollins, Nancy K.; Liang, Hui; Park, Yong Jong

    2015-01-01

    Purpose: Most orthodontic appliances are made of stainless steel materials and induce severe magnetic susceptibility artifacts in brain MRI. In an effort for correcting these artifacts, it is important to know the value of induced magnetic moments in all parts of orthodontic appliances. In this study, the induced magnetic moment of stainless steel orthodontic brackets, molar bands, and arch-wires from several vendors is measured. Methods: Individual stainless steel brackets, molar bands, and short segments of arch-wire were positioned in the center of spherical flask filled with water through a thin plastic rod. The induced magnetic moment at 1.5 T was determined by fitting the B0 map to the z-component of the magnetic dipole field using a computer routine. Results: The induced magnetic moment at 1.5 T was dominated by the longitudinal component mz, with a small contribution from the transverse components. The mz was insensitive to the orientation of the metal parts. The orthodontic brackets collectively dominated the magnetic dipole moment in orthodontic appliances. In brackets from six vendors, the total induced mz from 20 brackets for nonmolar teeth ranged from 0.108 to 0.158 (median 0.122) A ⋅ m2. The mz in eight molar bands with bracket attachment from two vendors ranged from 0.0004 to 0.0166 (median 0.0035) A ⋅ m2. Several full length arch wires had induced magnetic moment in the range of 0.006–0.025 (median 0.015) A ⋅ m2. Conclusions: Orthodontic brackets collectively contributed most to the total magnetic moment. Different types of brackets, molar bands, and arch wires all exhibit substantial variability in the induced magnetic moment. PMID:26429261

  16. 1.5 T conventional MR-guided iodine-125 interstitial implants for hepatocellular carcinoma: Feasibility and preliminary clinical experience

    International Nuclear Information System (INIS)

    Lin Zhengyu; Lin Jun; Lin Cong; Li Yinguan; Chen Shaoming; Hu Jianping; Hu Rui; Chen Jin

    2012-01-01

    Purpose: To evaluate the feasibility and therapeutic efficacy of 1.5 T conventional MR-guided percutaneous interstitial implantation of I-125 radioactive seeds in patients with hepatocellular carcinoma (HCC). Materials and methods: The institutional ethics committee approved this study. After imformed consent was obtained, twenty-three patients suffering from a total of 65 HCC lesions were treated with I-125 seed permanent interstitial implantation under the guidance of a 1.5 T conventional magnetic resonance imaging (MRI) system. The FSE T2WI, T1 FSPGR, FIESTA 2D, 3D Dyn T1WI sequences were used to guide an 18G MR-compatible needle inserted into the lesions to introduce the I-125 seeds. The response evaluation criteria in solid tumors (RECIST) were used to evaluate the curative effect. Results: The needle and I-125 seed were seen clearly on MRI images. The final dose delivered to total decay was 173.46 ± 32.44 Gy (range, 110–270 Gy) as calculated by postoperative TPS. The complete response (CR) was seen in 22 lesions (33.8%), partial response (PR) in 24 lesions (36.9%), stable disease (SD) in 9 lesions (13.8%), and progressive disease (PD) in 10 lesions (15.4%). The post-operative alpha-fetoprotein (AFP) was decreased (t = 3.117, P = 0.005 < 0.05). Two patients were observed a small area of subcapsular bleeding that did not lead to any symptoms or clinical sequelae. Conclusion: MR-guided I-125 implantation for HCC is technically feasible and effective.

  17. Experimental acute intracerebral hemorrhage: Value of MR sequences for a safe diagnosis at 1.5 and 0.5 T

    International Nuclear Information System (INIS)

    Kueker, W.; Thron, A.; Thiex, R.; Rohde, I.; Rohde, V.

    2000-01-01

    To determine the detectability of intracerebral hematomas with MR imaging at 1.5 T and 0.5 T with fluid attenuated inversion recovery turbo spin-echo (FLAIR) and gradient-echo sequences. Material and Methods: Twenty-seven intracerebral hematomas were created in 25 piglets by injection of venous blood into the brain through a burr hole. All were imaged with T2*-weighted gradient echo sequences (fast field echo, FFE), T2-weighted fluid attenuated inversion recovery turbo spin-echo sequences (FLAIR), T2-weighted turbo spin-echo (TSE) and T1-weighted spin-echo sequences. Follow-up was performed on the 2nd, 4th and 10th postoperative days. Ten animals were additionally investigated with similar sequences at 0.5 T. Histologic correlation was obtained in all cases. Results: T2* FFE sequences detected all acute intracerebral hematomas and demonstrated the size correctly at 1.5 T and 0.5 T. The conspicuity was better at 1.5 T. FLAIR sequences were unreliable in the hyperacute phase at 1.5 T. However, subarachnoid and intraventricular extension was best appreciated with FLAIR images. T2 TSE images were incapable of detecting para ventricular and subarachnoid hemorrhages, but clearly demonstrated intracerebral blood in other locations. T1-weighted images were insensitive to hemorrhage in the acute state but very useful in subacute and chronic hematomas. Conclusion: The safe and reliable diagnosis of intracerebral hemorrhage is probably possible with MR imaging at 1.5 T and 0.5 T even of hematomas less than 90 min old, but requires the application of at least FLAIR, T2* FFE and T1 sequences and is therefore time consuming

  18. Accuracy of 3 T versus 1.5 T breast MRI for pre-operative assessment of extent of disease in newly diagnosed DCIS

    Energy Technology Data Exchange (ETDEWEB)

    Rahbar, Habib, E-mail: hrahbar@uw.edu; DeMartini, Wendy B.; Lee, Amie Y.; Partridge, Savannah C.; Peacock, Sue; Lehman, Constance D.

    2015-04-15

    Highlights: •We compared sizes of known ductal carcinoma in situ (DCIS) on pre-operative breast MRI at 3 T and 1.5 T with final pathology sizes. •DCIS sizes on 3 T MRI correlated better with pathologic sizes than 1.5 T MRI. •Imaging features of DCIS, including morphology and kinetics, were similar at 3 T and 1.5 T MRI. -- Abstract: Objectives: While 3 T breast magnetic resonance imaging has increased in use over the past decade, there is little data comparing its use for assessing ductal carcinoma in situ (DCIS) versus 1.5 T. We sought to compare the accuracies of DCIS extent of disease measures on pre-operative 3 T versus 1.5 T MRI. Methods: This institutional review board-approved prospective study included 20 patients with ductal carcinoma in situ diagnosed by core needle biopsy (CNB) who underwent pre-operative breast MRI at both 3 T (resolution = 0.5 mm × 0.5 mm × 1.3 mm) and 1.5 T (0.85 mm × 0.85 mm × 1.6 mm). All patients provided informed consent, and the study was HIPPA compliant. Lesion sizes and imaging characteristics (morphologic and kinetic enhancement) were recorded for the 3 T and 1.5 T examinations. Lesion size measures at both field strengths were correlated to final pathology, and imaging characteristics also were compared. Results: Of the initial cohort of 20 patients with CNB-diagnosed DCIS, 19 underwent definitive surgery. Median DCIS sizes of these 19 patients were 6 mm (range: 0–67 mm) on 3 T, 13 mm (0–60 mm) on 1.5 T, and 6 mm (0–55 mm) on surgical pathology. Size correlation between MRI and pathology was higher for 3 T (Spearman's ρ = 0.66, p = 0.002) than 1.5 T (ρ = 0.36, p = 0.13). In 10 women in which a residual area of suspicious enhancement was identified on both field strengths, there was agreement of morphologic description (NME vs. mass) in nine, and no significant difference in dynamic contrast enhanced kinetics at 3 T compared to 1.5 T. Conclusions: Pre-operative breast MRI at 3 T provided higher

  19. High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3 T vs. 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Arizono, Shigeki [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: arizono@kuhp.kyoto-u.ac.jp; Isoda, Hiroyoshi [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: sayuki@kuhp.kyoto-u.ac.jp; Maetani, Yoji S. [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: mbo@kuhp.kyoto-u.ac.jp; Hirokawa, Yuusuke [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: yuusuke@kuhp.kyoto-u.ac.jp; Shimada, Kotaro [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: kotaro@kuhp.kyoto-u.ac.jp; Nakamoto, Yuji [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ynakamo1@kuhp.kyoto-u.ac.jp; Shibata, Toshiya [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ksj@kuhp.kyoto-u.ac.jp; Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ktogashi@kuhp.kyoto-u.ac.jp

    2010-01-15

    Purpose: The aim of this study was to evaluate image quality of 3D MR cholangiography (MRC) using high sampling efficiency technique (SPACE) at 3 T compared with 1.5 T. Methods and materials: An IRB approved prospective study was performed with 17 healthy volunteers using both 3 and 1.5 T MR scanners. MRC images were obtained with free-breathing navigator-triggered 3D T2-weighted turbo spin-echo sequence with SPACE (TR, >2700 ms; TE, 780 ms at 3 T and 801 ms at 1.5 T; echo-train length, 121; voxel size, 1.1 mm x 1.0 mm x 0.84 mm). The common bile duct (CBD) to liver contrast-to-noise ratios (CNRs) were compared between 3 and 1.5 T. A five-point scale was used to compare overall image quality and visualization of the third branches of bile duct (B2, B6, and B8). The depiction of cystic duct insertion and the highest order of bile duct visible were also compared. The results were compared using the Wilcoxon signed-ranks test. Results: CNR between the CBD and liver was significantly higher at 3 T than 1.5 T (p = 0.0006). MRC at 3 T showed a significantly higher overall image quality (p = 0.0215) and clearer visualization of B2 (p = 0.0183) and B6 (p = 0.0106) than at 1.5 T. In all analyses of duct visibility, 3 T showed higher scores than 1.5 T. Conclusion: 3 T MRC using SPACE offered better image quality than 1.5 T. SPACE technique facilitated high-resolution 3D MRC with excellent image quality at 3 T.

  20. 3D Cones Acquisition of Human Extremity Imaging Using a 1.5T Superconducting Magnet and an Unshielded Gradient Coil Set.

    Science.gov (United States)

    Setoi, Ayana; Kose, Katsumi

    2018-05-16

    We developed ultrashort echo-time (UTE) imaging sequences with 3D Cones trajectories for a home-built compact MRI system using a 1.5T superconducting magnet and an unshielded gradient coil set. We achieved less than 7 min imaging time and obtained clear in vivo images of a human forearm with a TE of 0.4 ms. We concluded that UTE imaging using 3D Cones acquisition was successfully implemented in our 1.5T MRI system.

  1. Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Xin; Bevilacqua, Elisa; Cos Sanchez, Teresa; Jani, Jacques C. [University Hospital Brugmann, Universite Libre de Bruxelles, Department of Obstetrics and Gynecology, Fetal Medicine Unit, Brussels (Belgium); Cannie, Mieke M. [University Hospital Brugmann, Universite Libre de Bruxelles, Department of Radiology, Brussels (Belgium); Vrije Universiteit Brussel, Department of Radiology, UZ Brussel, Brussels (Belgium); Arthurs, Owen J.; Sebire, Neil J. [Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Child Health, London (United Kingdom); Segers, Valerie; Fourneau, Catherine [University Hospital Brugmann, Universite Libre de Bruxelles, Department of Fetopathology, Brussels (Belgium)

    2017-08-15

    To prospectively compare diagnostic accuracy of fetal post-mortem whole-body MRI at 3-T vs. 1.5-T. Between 2012 and 2015, post-mortem MRI at 1.5-T and 3-T was performed in fetuses after miscarriage/stillbirth or termination. Clinical MRI diagnoses were assessed using a confidence diagnostic score and compared with classical autopsy to derive a diagnostic error score. The relation of diagnostic error for each organ group with gestational age was calculated and 1.5-T with 3-T was compared with accuracy analysis. 135 fetuses at 12-41 weeks underwent post-mortem MRI (followed by conventional autopsy in 92 fetuses). For all organ groups except the brain, and for both modalities, the diagnostic error decreased with gestation (P < 0.0001). 3-T MRI diagnostic error was significantly lower than that of 1.5-T for all anatomic structures and organ groups, except the orbits and brain. This difference was maintained for fetuses <20 weeks gestation. Moreover, 3-T was associated with fewer non-diagnostic scans and greater concordance with classical autopsy than 1.5-T MRI, especially for the thorax, heart and abdomen in fetuses <20 weeks. Post-mortem fetal 3-T MRI improves confidence scores and overall accuracy compared with 1.5-T, mainly for the thorax, heart and abdomen of fetuses <20 weeks of gestation. (orig.)

  2. Pancreatic Duct in Autoimmune Pancreatitis: Intraindividual Comparison of Magnetic Resonance Pancreatography at 1.5 T and 3.0 T.

    Science.gov (United States)

    Kim, Jin Hee; Byun, Jae Ho; Kim, Myung-Hwan; Lee, Sung Koo; Kim, Song Cheol; Kim, Hyoung Jung; Lee, Seung Soo; Kim, So Yeon; Lee, Moon-Gyu

    2017-08-01

    The aim of this study was to intraindividually compare magnetic resonance pancreatography (MRP) image quality at 1.5 T and 3.0 T when demonstrating main pancreatic duct (MPD) abnormalities in patients with autoimmune pancreatitis (AIP). Thirty prospectively enrolled patients with AIP underwent MRP at both 1.5 T and 3.0 T followed by endoscopic retrograde pancreatography before treatment. Two readers independently analyzed the MRP images and graded the visualization of MPD strictures and full-length MPD, using endoscopic retrograde pancreatography as the reference standard, as well as overall image artifacts on a 4-point scale. The contrast between the MPD and periductal area was calculated using a region-of-interest measurement. Visualization scores of MPD strictures and full-length MPD, and summed scores of each qualitative analysis, were significantly greater at 3.0-T MRP than at 1.5-T MRP for both readers (P ≤ 0.02). There were less image artifacts at 3.0 T compared with 1.5 T (P ≤ 0.052). The contrast between the MPD and periductal area was significantly greater at 3.0-T MRP than at 1.5-T MRP (P 3.0 T was superior to 1.5-T MRP for demonstrating MPD abnormalities in AIP, with better image contrast and fewer image artifacts. Consequently, 3.0-T MRP may be useful for the diagnosis and management of patients with AIP.

  3. Value of magnetic resonance mammographic at 1.5 T in the differential diagnosis of mastitis versus inflammatory carcinoma

    International Nuclear Information System (INIS)

    Tomczak, R.; Rieber, A.; Zeitler, H.; Rilinger, N.; Kreienberg, R.; Brambs, H.J.

    1996-01-01

    Purpose: The distinction between mastitis and inflammatory breast carcinoma is an important one. Current methods of evaluation including mammography, ultrasound and clinical examination do not enable this distinction. Dynamic magnetic resonance mammography (MRM) is a study with potential in this regard. Material and methods: 12 patients, in whom clinical examination, mammography and ultrasound could not distinguish between both diseases, were reviewed retrospectively by means of MRM using a 1.5 T Siemens Magnetom SP and a circular mamma coil. We used dynamic 3-D gradient echo sequences with a duration of one minute. Results: At present MRM cannot definitely distinguish between mastitis and inflammatory carcinoma, 80% of the inflammatory carcinomas were found to enhance more than 100% in the first minute, compared to 43% for mastitis. No other differences were seen. Conclusion: MRM proved useful in the follow-up of treated mastitis to demonstrate the success of antibiotic treatment of mastitis and to diagnose a histologically unconfirmed inflammatory carcinoma by means of a different follow-up. (orig.) [de

  4. Fluorine cardiovascular magnetic resonance angiography in vivo at 1.5 T with perfluorocarbon nanoparticle contrast agents.

    Science.gov (United States)

    Neubauer, Anne M; Caruthers, Shelton D; Hockett, Franklin D; Cyrus, Tillman; Robertson, J David; Allen, J Stacy; Williams, Todd D; Fuhrhop, Ralph W; Lanza, Gregory M; Wickline, Samuel A

    2007-01-01

    While the current gold standard for coronary imaging is X-ray angiography, evidence is accumulating that it may not be the most sensitive technique for detecting unstable plaque. Other imaging modalities, such as cardiovascular magnetic resonance (CMR), can be used for plaque characterization, but suffer from long scan and reconstruction times for determining regions of stenosis. We have developed an intravascular fluorinated contrast agent that can be used for angiography with cardiovascular magnetic resosnace at clinical field strengths (1.5 T). This liquid perfluorocarbon nanoparticle contains a high concentration of fluorine atoms that can be used to generate contrast on 19F MR images without any competing background signal from surrounding tissues. By using a perfluorocarbon with 20 equivalent fluorine molecules, custom-built RF coils, a modified clinical scanner, and an efficient steady-state free procession sequence, we demonstrate the use of this agent for angiography of small vessels in vitro, ex vivo, and in vivo. The surprisingly high signal generated with very short scan times and low doses of perfluorocarbon indicates that this technique may be useful in clinical settings when coupled with advanced imaging strategies.

  5. Rapid whole brain myelin water content mapping without an external water standard at 1.5T.

    Science.gov (United States)

    Nguyen, Thanh D; Spincemaille, Pascal; Gauthier, Susan A; Wang, Yi

    2017-06-01

    The objective of this study is to develop rapid whole brain mapping of myelin water content (MWC) at 1.5T. The Fast Acquisition with Spiral Trajectory and T2prep (FAST-T2) pulse sequence originally developed for myelin water fraction (MWF) mapping was modified to obtain fast mapping of T1 and receiver coil sensitivity needed for MWC computation. The accuracy of the proposed T1 mapping was evaluated by comparing with the standard IR-FSE method. Numerical simulations were performed to assess the accuracy and reliability of the proposed MWC mapping. We also compared MWC values obtained with either cerebrospinal fluid (CSF) or an external water tube attached to the subject's head as the water reference. Our results from healthy volunteers show that whole brain MWC mapping is feasible in 7min and provides accurate brain T1 values. Regional brain WC and MWC measurements obtained with the internal CSF-based water standard showed excellent correlation (R>0.99) and negligible bias within narrow limits of agreement compared to those obtained with an external water standard. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Distinct symmetry and limited peptide refolding activity of the thermosomes from the acidothermophilic archaea Acidianus tengchongensis S5T

    International Nuclear Information System (INIS)

    Wang, Li; Hu, Zhong-jun; Luo, Yuan-ming; Huo, Yan-wu; Ma, Qing; He, Yong-zhi; Zhang, Yu-ying; Sun, Fei; Dong, Zhi-yang

    2010-01-01

    Recombinant thermosomes from the Acidianus tengchongensis strain S5 T were purified to homogeneity and assembled in vitro into homo-oligomers (rATcpnα or rATcpnβ) and hetero-oligomers (rATcpnαβ). The symmetries of these complexes were determined by electron microscopy and image analysis. The rATcpnα homo-oligomer was shown to possess 8-fold symmetry while both rATcpnβ and rATcpnαβ oligomers adopted 9-fold symmetry. rATcpnαβ oligomers were shown to contain the α and β subunits in a 1:2 ratio. All of the complexes prevented the irreversible inactivation of yeast alcohol dehydrogenase at 55 o C and completely prevented the formation of aggregates during thermal inactivation of citrate synthase at 45 o C. All rATcpn complexes showed trace ATP hydrolysis activity. Furthermore, rATcpnβ sequestered fully chemically denatured substrates (GFP and thermophilic malic dehydrogenase) in vitro without refolding them in an ATP-dependent manner. This property is similar to previously reported properties of chaperonins from Sulfolobus tokodaii and Sulfolobus acidocaldarius. These features are consistent with the slow growth rates of these species of archaea in their native environment.

  7. The Missense Alteration A5T of the Thyroid Peroxidase Gene is Pathogenic and Associated with Mild Congenital Hypothyroidism.

    Science.gov (United States)

    Cangül, Hakan; Demir, Korcan; Babayiğit, H Ömür; Abacı, Ayhan; Böber, Ece

    2015-09-01

    Congenital hypothyroidism (CH) occurs with a prevalence of approximately 1:4000 live births. Defects of thyroid hormone synthesis account for 15-20% of these cases. Thyroid peroxidase (TPO) gene is the most common cause for dyshormonogenesis. So far, more than 60 mutations in the TPO gene have been described, resulting in a variable decrease in TPO bioactivity. We present an 8-day-old male with mild CH who was identified to have a G to A transition in the fifth codon of the TPO gene (c.13G>A; p.Ala5Thr). The unaffected family members were heterozygous carriers of the mutation, whereas 400 healthy individuals of the same ethnic background did not have the mutation. Mutation analysis of 11 known causative CH genes and 4 of our own strong candidate genes with next-generation sequencing revealed no mutations in the patient nor in any other family members. The results of in silico functional analyses indicated partial loss-of-function (LOF) in the resulting enzyme molecule due to mutation. The patient's clinical finding s were consistent with the effect of this partial LOF of the mutation. In conclusion, we strongly believe that A5T alteration in the TPO gene is actually pathogenic and suggest that it should be classified as a mutation.

  8. Bone marrow lesions: evaluation with fat-suppression turbo spin echo MR imaging at 0.5T

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Papazoglou, A.; Roussakis, A.; Andreou, J.

    1996-01-01

    The purpose of this study was the assessment of the diagnostic value of fat-suppression T2-weighted images for a variety of bone marrow lesions. We performed 40 studies of the axial or appendicular skeleton in 33 patients (age range 4-80 years) with neoplastic, inflammatory or traumatic lesions with a 0.5 T system (Gyroscan T5, Philips Medical Systems, Best, The Netherlands). Fat-suppression T2-weighted images [turbo spin echo (TSE) with spectral presaturation with inversion recovery (SPIR)] were obtained in addition to the routine T1-weighted SE and T2-weighted TSE sequences. Fat-suppression TSE T2-weighted images were better than standard TSE T2-weighted images in 25 studies. In 11 of them demonstration and characterization of the lesions (known from T1-weighted images) was possible only after fat suppression. In the other 14 patients demonstration of the full extent of the lesion especially to the nearby soft tissues was possible only after fat suppression. In 13 studies no advantage was conferred by SPIR, whereas in two instances T2-weighted images were better. Fat-suppression T2-weighted images are diagnostically useful in a variety of lesions of the musculoskeletal system, but their limitations should be known. (orig.)

  9. Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Dietrich, J.; Lieberenz, S.; Schmidt, F.; Sorge, O.; Trantakis, C.; Seifert, V.; Kellermann, S.; Schober, R.; Franke, P.

    1999-01-01

    The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR ''SIGNA SP'' (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device ''Flashpoint Position Encoder'' (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence. (orig.)

  10. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    Science.gov (United States)

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  11. Artifacts in MRI of the temporomandibular joint caused by dental alloys: a phantom study at 1.5 T

    International Nuclear Information System (INIS)

    Fellner, C.; Erlangen-Nuernberg Univ., Erlangen; Behr, M.; Fellner, F.; Held, P.; Handel, G.; Feuerbach, S.

    1997-01-01

    Purpose: The influence of dental alloys on MRI of the temporomandibular joint was studied using a phantom model for this joint. Methods: At 1,5 T, 15 dental alloys and 14 of their most important components were investigated acquiring sagittal (FOV: 150 mm) and transverse (FOV: 250 mm) T 1 -weighted SE additionally. The artifacts were assessed qualitatively as well as quantitatively, and the samples were subdivided into four artifact categories. Results: Ag, Cu, Ga, In, Ti, Sn, Zn, amalgan, the precious alloys, the Au-Pd and Ag-Pd alloys showed no artifacts (category I). Minimal artifacts below 10 mm on transverse images (category II) were found for Cr, Pd, Pt and for the Ni-Cr alloy. Mn and the remaining non-precious alloys induced artifacts up to 30 mm (category III). Significant artifacts - more than 30 mm - (category IV) were to be more susceptible for artifacts than T 1 -weighted SE and FLASH techniques. Conclusions: In contrast to dental alloys for fixed prosthodontics, Ni-Cr- or 18/8 wires used for orthodontic bands can influence not only the image quality, but also the diagnostic reliability of MRI of the temporomandibular joint. (orig.) [de

  12. Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.

    Science.gov (United States)

    Jeong, Daniel; Schiebler, Mark L; Lai, Peng; Wang, Kang; Vigen, Karl K; François, Christopher J

    2015-04-01

    Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left ventricular function. CMR examinations were performed on fifteen patients and three healthy volunteers on a clinical 1.5T scanner using a two-dimensional (2D) cine balanced SSFP CMR sequence (2D cine bSSFP) followed by an investigational 3D cine bSSFP pulse sequence acquired within a single breath hold. Left ventricular end diastolic volume (LVEDV), end systolic volume (LVESV), ejection fraction (LVEF), and myocardial mass were independently segmented on a workstation by two experienced radiologists. Blood pool to myocardial contrast was evaluated in consensus using a Likert scale. Bland-Altman analysis was used to compare these quantitative and nominal measurements for the two sequences. The average acquisition time was significantly shorter for the 3D cine bSSFP than for 2D cine bSSFP (0.36 ± 0.03 vs. 8.5 ± 2.3 min) p = 0.0002. Bland-Altman analyses [bias and (limits of agreement)] of the data derived from these two methods revealed that the LVEF 0.9% (-4.7, 6.4), LVEDV 4.9 ml (-23.0, 32.8), LVESV -0.2 ml (-22.4, 21.9), and myocardial mass -0.4 g (-23.8, 23.0) were not significantly different. There was excellent intraclass correlation for intra-observer variability (0.981, 0.989, 0.997, 0.985) and inter-observer variability (0.903, 0.954, 0.970, 0.842) for LVEF, LVEDV, LVESV, and myocardial mass respectively. 3D cine bSSFP allows for accurate single breath-hold volumetric cine CMR which enables substantial improvements in scanner time efficiency without sacrificing diagnostic accuracy.

  13. Part-body hyperthermia with a radiofrequency multiantenna applicator under online control in 1,5 T MR-tomograph

    International Nuclear Information System (INIS)

    Wust, P.; Gellermann, J.; Faehling, H.; Wlodarczyk, W.; Felix, R.; Seebass, M.; Turner, P.; Nadobny, J.; Rau, B.; Hildebrandt, B.; Schlag, P.M.; Oppelt, A.

    2004-01-01

    Objective of this study is the integration of a multiantenna applicator for part-body hyperthermia (BSD 2000/3D) in a 1.5 T MR-tomograph (Siemens Magnetom Symphony) in order to perform noninvasive MR monitoring in real time to increase safety and effectiveness of heat treatments. The positioning unit is mechanically coupled to the MR gantry from the back side and the body coil is utilised for imaging. For that purpose, the hyperthermia antenna system (100 MHz, 1.500 W) and the MR receiver(63.9 MHs) have to be decoupled in terms of high frequency (filter) and electromagnetically (emc). The processing of MR data sets is performed in a hyperthermia planning system. A simultaneous operation of radiofrequency hyperthermia and MR system is possible at clinically relevant power levels. MR imaging is used for tumor diagnostics (standard spin echo sequences), for hyperthermia planning (T1-weighted gradient echo sequences in equal- and opposed-phase techniques), and for temperature measurements according to the proton resonance frequency method (PRF method, phase evaluation registration using a gradient echo sequence with long echo time). In 33 patients with advanced pelvic and abdominal tumors we performed 150 heat sessions under MR monitoring. For 70% of these patients a visualisation of temperature sensitive data during treatment was possible. The evaluated difference images represent a superposition of real temperature increase and a (temperature-induced) perfusion elevation. The hybrid approach renders development of part body hyperthermia possible as an MR-controlled intervention in radiology. (orig.) [de

  14. Lingering fat signals with CHESS in simultaneous imaging of both hands can be improved with rice pads in both 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Susumu, E-mail: smoyari@yahoo.co.jp [Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 920-0942 (Japan); Ishikawa Clinic, 46-1 Shimokamo-Umenoki-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-0851 (Japan); Miki, Yukio, E-mail: yukio.miki@med.osaka-cu.ac.jp [Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585 (Japan); Kamishima, Tamotsu, E-mail: ktamotamo2@yahoo.co.jp [Department of Biomedical Sciences and Engineering, Hokkaido University Graduate School of Health Science, North-12 West-5 Kita-ku, Sapporo 060-0812 (Japan); Miyati, Tosiaki, E-mail: ramiyati@mhs.mp.kanazawa-u.ac.jp [Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 920-0942 (Japan); Kanagaki, Mitsunori, E-mail: mitsuk@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawahara-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-8507 (Japan); Matsuno, Yukako, E-mail: ynoma2000jp@yahoo.co.jp [Oike Clinic, 11 Nishinokyo-Shimoai-cho, Nakagyo-ku, Kyoto-shi, Kyoto 604-8436 (Japan); Yokobayashi, Tsuneo, E-mail: mri@mrnet.jp [Ishikawa Clinic, 46-1 Shimokamo-Umenoki-cho, Sakyo-ku, Kyoto-shi, Kyoto 606-0851 (Japan)

    2013-09-15

    Objectives: To investigate whether rice pads can eliminate lingering fat signals of the complex surface shape of both hands that occur with chemical shift selective (CHESS) at 1.5 T and 3.0 T. Materials and methods: T1-weighted images were obtained with CHESS using 1.5 T and 3.0 T systems. The same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. The fat-suppression effects were classified into four categories and scored for images, and visual evaluations were performed by one radiologist and one radiologic technologist. Results: At 1.5 T, the mean evaluation score was 1.55 for images obtained without rice pads and 3.50 for images obtained with rice pads. At 3.0 T, the mean evaluation score was 1.10 for images obtained without rice pads and 3.20 for images obtained with rice pads. With both systems, images obtained with the rice pads showed significantly better fat suppression effects than images obtained without rice pads (P < 0.0001, P < 0.0001). Conclusions: It was confirmed that lingering fat signals are eliminated and good fat-suppressed images are obtained with the use of rice pads at 1.5 T and 3.0 T. Rice pads are therefore useful with at 1.5 T and 3.0 T, which are currently becoming more widely used.

  15. Lingering fat signals with CHESS in simultaneous imaging of both hands can be improved with rice pads in both 1.5 T and 3.0 T

    International Nuclear Information System (INIS)

    Moriya, Susumu; Miki, Yukio; Kamishima, Tamotsu; Miyati, Tosiaki; Kanagaki, Mitsunori; Matsuno, Yukako; Yokobayashi, Tsuneo

    2013-01-01

    Objectives: To investigate whether rice pads can eliminate lingering fat signals of the complex surface shape of both hands that occur with chemical shift selective (CHESS) at 1.5 T and 3.0 T. Materials and methods: T1-weighted images were obtained with CHESS using 1.5 T and 3.0 T systems. The same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. The fat-suppression effects were classified into four categories and scored for images, and visual evaluations were performed by one radiologist and one radiologic technologist. Results: At 1.5 T, the mean evaluation score was 1.55 for images obtained without rice pads and 3.50 for images obtained with rice pads. At 3.0 T, the mean evaluation score was 1.10 for images obtained without rice pads and 3.20 for images obtained with rice pads. With both systems, images obtained with the rice pads showed significantly better fat suppression effects than images obtained without rice pads (P < 0.0001, P < 0.0001). Conclusions: It was confirmed that lingering fat signals are eliminated and good fat-suppressed images are obtained with the use of rice pads at 1.5 T and 3.0 T. Rice pads are therefore useful with at 1.5 T and 3.0 T, which are currently becoming more widely used

  16. Lingering fat signals with CHESS in simultaneous imaging of both hands can be improved with rice pads in both 1.5T and 3.0T.

    Science.gov (United States)

    Moriya, Susumu; Miki, Yukio; Kamishima, Tamotsu; Miyati, Tosiaki; Kanagaki, Mitsunori; Matsuno, Yukako; Yokobayashi, Tsuneo

    2013-09-01

    To investigate whether rice pads can eliminate lingering fat signals of the complex surface shape of both hands that occur with chemical shift selective (CHESS) at 1.5T and 3.0T. T1-weighted images were obtained with CHESS using 1.5T and 3.0T systems. The same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. The fat-suppression effects were classified into four categories and scored for images, and visual evaluations were performed by one radiologist and one radiologic technologist. At 1.5T, the mean evaluation score was 1.55 for images obtained without rice pads and 3.50 for images obtained with rice pads. At 3.0T, the mean evaluation score was 1.10 for images obtained without rice pads and 3.20 for images obtained with rice pads. With both systems, images obtained with the rice pads showed significantly better fat suppression effects than images obtained without rice pads (P<0.0001, P<0.0001). It was confirmed that lingering fat signals are eliminated and good fat-suppressed images are obtained with the use of rice pads at 1.5T and 3.0T. Rice pads are therefore useful with at 1.5T and 3.0T, which are currently becoming more widely used. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Evaluation of turbo spin echo sequences for MRI of focal liver lesions at 0.5 T

    International Nuclear Information System (INIS)

    Kreft, B.; Layer, G.; Steudel, A.; Spiller, L.; Heuck, A.; Mueller, A.; Gieseke, J.; Reiser, M.F.

    1994-01-01

    To determine whether turbo spin echo (TSE) sequences can replace conventional T2-weighted spin echo (SE) sequences in MRI of the liver, 40 patients with focal liver lesions were imaged at 0.5 T. A T2-weighted SE sequence (TR/TE 1800/90 ms, number of signals averaged [NEX] = 2, scan time 7:16 min), a TSE sequence (TR/TE 1800/90 ms, NEX = 4, number of echos per excitation = 13, echo spacing = 12.9 ms, scan time = 4:16 min) and a T1-weighted SE sequence (TR/TE 350/15 ms, NEX = 2, scan time = 4:21 min) were obtained and image quality, lesion detectability and lesion differentiation were evaluated qualitatively by subjective assessment using scores and quantitatively by lesion-liver contrast-to-noise (CNR) and tumour/liver signal intensity (SI) ratios. The image quality of the TSE sequence was substantially better compared with the T2-weighted SE sequence due to a reduction in motion artefacts and better delineation of anatomical details. Of a total of 158 visible lesions the T1-weighted SE, TSE and T2-weighted SE sequences showed 91 %, 81 % and 65 % of the lesions, respectively. Thus the TSE sequence depicted 24 % (P < 0.001) more lesions than the T2-weighted SE sequence. In all types of pathology the lesion-liver CNR of the TSE sequence was significantly (P < 0.001) higher compared to the CNR of the T2-weighted SE sequence ( +55-65 %), indicating superior lesion conspicuity. Lesion characterization was equally good on the two T2-weighted sequences with no difference in the tumour/liver SI ratio. Using a criterion of tumour/liver SI ratio equal to or higher than 2, haemangiomas larger than 1 cm in diameter could be differentiated from other lesions with a sensitivity and specificity of 95 % and 96 %, respectively. Our results indicate that the TSE sequence is suitable for replacing the conventional T2-weighted SE sequence in MRI of focal liver lesions. (orig.)

  18. Quantitative and qualitative evaluation of brain diffusion weighted magnetic resonance imaging comparison with 1.5 T and 3.0 T units

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Eun Hoe [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-02-15

    DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging . In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5 T and 3.0 T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5 T.

  19. Quantitative evaluation of perfusion magnetic resonance imaging hyper-acute ischemic stroke patients comparison with 1.5T and 3.0T units

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Eun Hoe [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-02-15

    Perfusion magnetic resonance image of biological mechanism are independent of magnetic field strength in hyper acute ischemic stroke. 3.0 T magnetic field, however, does affect the SNRs (signal to noise ratio) and artifacts of PMRI (perfusion magnetic resonance image), which basically will influence the quantitative of PMRI. In this study, the effects of field strength on PMRI are analyzed. The effects of the diseases also are discussed. PMRI in WM (white matter), GM (gray matter), hyper acute ischemic stroke were companied with 1.5 T and 3.0 T on SNR. PMRI also was compared to the SI difference after setting ROI (region of interest) in left and right b side of the brain. In conclusion, the SNRs and SI of the 3.0 T PMRI showed higher than those at 1.5 T. In summary, PMRI studies at 3.0 T is provided significantly improved perfusion evaluation when comparing with 1.5 T.

  20. Quantitative evaluation of perfusion magnetic resonance imaging hyper-acute ischemic stroke patients comparison with 1.5T and 3.0T units

    International Nuclear Information System (INIS)

    Goo, Eun Hoe; Moon, Il Bong; Dong, Kyung Rae

    2017-01-01

    Perfusion magnetic resonance image of biological mechanism are independent of magnetic field strength in hyper acute ischemic stroke. 3.0 T magnetic field, however, does affect the SNRs (signal to noise ratio) and artifacts of PMRI (perfusion magnetic resonance image), which basically will influence the quantitative of PMRI. In this study, the effects of field strength on PMRI are analyzed. The effects of the diseases also are discussed. PMRI in WM (white matter), GM (gray matter), hyper acute ischemic stroke were companied with 1.5 T and 3.0 T on SNR. PMRI also was compared to the SI difference after setting ROI (region of interest) in left and right b side of the brain. In conclusion, the SNRs and SI of the 3.0 T PMRI showed higher than those at 1.5 T. In summary, PMRI studies at 3.0 T is provided significantly improved perfusion evaluation when comparing with 1.5 T

  1. Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Breitenseher, M.J. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Huber, M. [Pathologisch-Bakteriologisches Inst. Baumgartner Hoehe, Wien (Austria); Zettl, R. [Orthopaedisches Krankenhaus Gersthof, Wien (Austria); Rottmann, B. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Haller, J. [Hanuschkrankenhaus, Wien (Austria). Radiologische Abt.; Imhof, H. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria)

    1997-04-01

    Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep calcified cartilage layer was measured. Results: Measurements without the transition zone showed a mean underestimation of talus cartilage thickness of 46.8% (41.3-52.1) for T{sub 1}-SE and 47.5% (43.1-52.1) for fat saturated FLASH-3D images. Considering the transition zone the mean values were 25.0% (23.1-26.2) and 14.1% (6.7-21.5). The histologic specimens showed a three-fold increase of thickness of deep calcified cartilage layer. Conclusions: Measurements of the cartilage layer of the ankle joint on MR images are only accurate if the transition zone (calcified cartilage layer) is considered and the optimal pulse sequence (FLASH-3D-fat-sat) is applied. (orig.) [Deutsch] Ziel: Die Frage, ob die MRT die Dicke des Knorpels exakt bestimmen kann, wird kontrovers diskutiert. Ziel der Studie war die Bestimmung der Knorpeldicke am oberen Sprunggelenk mit der MRT im Vergleich zum anatomischen Praeparat. Material und Methode: Sprunggelenke von 4 Leichen wurden auf einem 1,5 Tesla MR-Geraet mittels T{sub 1}-betonter Spin

  2. Phase II trial of Modified Vaccinia Ankara (MVA virus expressing 5T4 and high dose Interleukin-2 (IL-2 in patients with metastatic renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Mitcham Josephine

    2009-01-01

    Full Text Available Abstract Background Interleukin-2 (IL-2 induces durable objective responses in a small cohort of patients with metastatic renal cell carcinoma (RCC but the antigen(s responsible for tumor rejection are not known. 5T4 is a non-secreted membrane glycoprotein expressed on clear cell and papillary RCCs. A modified vaccinia virus Ankara (MVA encoding 5T4 was tested in combination with high-dose IL-2 to determine the safety, objective response rate and effect on humoral and cell-mediated immunity. Methods 25 patients with metastatic RCC who qualified for IL-2 were eligible and received three immunizations every three weeks followed by IL-2 (600,000 IU/kg after the second and third vaccinations. Blood was collected for analysis of humoral, effector and regulatory T cell responses. Results There were no serious vaccine-related adverse events. While no objective responses were observed, three patients (12% were rendered disease-free after nephrectomy or resection of residual metastatic disease. Twelve patients (48% had stable disease which was associated with improved median overall survival compared to patients with progressive disease (not reached vs. 28 months, p = 0.0261. All patients developed 5T4-specific antibody responses and 13 patients had an increase in 5T4-specific T cell responses. Although the baseline frequency of Tregs was elevated in all patients, those with stable disease showed a trend toward increased effector CD8+ T cells and a decrease in Tregs. Conclusion Vaccination with MVA-5T4 did not improve objective response rates of IL-2 therapy but did result in stable disease associated with an increase in the ratio of 5T4-specific effector to regulatory T cells in selected patients. Trial registration number ISRCTN83977250

  3. Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T

    International Nuclear Information System (INIS)

    Vidal, Arvin; Wade, Trevor; Rutt, Brian K; Fenster, Aaron; Parraga, Grace; Bureau, Yves; Spence, J David

    2008-01-01

    Carotid atherosclerosis measurements for eight subjects at baseline and 14 ± 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using coefficients of variation (COV), and intraclass correlation coefficients (ICC). VWV interscan variability and consistency at both field strengths were not statistically different (1.5 T/3.0 T COV = 5.7%/7.8%, R 2 = 0.96 for 1.5 T and R 2 = 0.87 for 3.0 T). A two-way analysis of variance showed a VWV dependence on field strength but not scan timepoint. In addition, a paired t-test showed significant differences in VWV measured at 3.0 T as compared to 1.5 T. These results suggest that although images acquired at 1.5 T have lower SNR and CNR VWV, measurement variability was not significantly different from 3.0 T VWV and that VWV is field-strength dependent which may be an important consideration for longitudinal studies.

  4. Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Arvin; Wade, Trevor; Rutt, Brian K; Fenster, Aaron; Parraga, Grace [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, N6A 5K8 (Canada); Bureau, Yves [Graduate Program in Biomedical Engineering, University of Western Ontario, London, N6A 5B9 (Canada); Spence, J David [Stroke Prevention and Atherosclerosis Research Centre, Robarts Research Institute, 1400 Western Road, London, N6A 5K8 (Canada)], E-mail: avidal@imaging.robarts.ca, E-mail: ybureau@lawsonimaging.ca, E-mail: twade@imaging.robarts.ca, E-mail: DSpence@robarts.ca, E-mail: brutt@imaging.robarts.ca, E-mail: afenster@imaging.robarts.ca, E-mail: gep@imaging.robarts.ca

    2008-12-07

    Carotid atherosclerosis measurements for eight subjects at baseline and 14 {+-} 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using coefficients of variation (COV), and intraclass correlation coefficients (ICC). VWV interscan variability and consistency at both field strengths were not statistically different (1.5 T/3.0 T COV = 5.7%/7.8%, R{sup 2} = 0.96 for 1.5 T and R{sup 2} = 0.87 for 3.0 T). A two-way analysis of variance showed a VWV dependence on field strength but not scan timepoint. In addition, a paired t-test showed significant differences in VWV measured at 3.0 T as compared to 1.5 T. These results suggest that although images acquired at 1.5 T have lower SNR and CNR VWV, measurement variability was not significantly different from 3.0 T VWV and that VWV is field-strength dependent which may be an important consideration for longitudinal studies.

  5. Total antioxidant capacity, total oxidant status and oxidative stress index in the men exposed to 1.5 T static magnetic field.

    Science.gov (United States)

    Sirmatel, O; Sert, C; Sirmatel, F; Selek, S; Yokus, B

    2007-06-01

    The aim of this study was to investigate the effects of a high-strength magnetic field produced by a magnetic resonance imaging (MRI) apparatus on oxidative stress. The effects of a 1.5 T static magnetic field on the total antioxidant capacity (TAC), total oxidant status (TOS) and oxidative stress index (OSI) in male subjects were investigated. In this study, 33 male volunteers were exposed to a 1.5 T static magnetic field for a short time and the TAC, TOS and OSI of each subject were determined. Magnetic field exposure was provided using a magnetic resonance apparatus; radiofrequency was not applied. Blood samples were taken from subjects and TAC, TOS and OSI values were measured using the methods of Erel. TAC showed a significant increase in post-exposures compared to pre-exposures to the magnetic field (p < 0.05). OSI and TOS showed a significant decrease in post-exposures compared to pre-exposures to a 1.5 T magnetic field (for each of two, p < 0.01). The 1.5 T static magnetic field used in the MRI apparatus did not yield a negative effect; on the contrary, it produced the positive effect of decreasing oxidative stress in men following short-term exposure.

  6. CHARACTERIZATION AND NUCLEOTIDE SEQUENCE DETERMINATION OF A REPEAT ELEMENT ISOLATED FROM A 2,4,5,-T DEGRADING STRAIN OF PSEUDOMONAS CEPACIA

    Science.gov (United States)

    Pseudomonas cepacia strain AC1100, capable of growth on 2,4,5-trichlorophenoxyacetic acid (2,4,5-T), was mutated to the 2,4,5-T− strain PT88 by a ColE1 :: Tn5 chromosomal insertion. Using cloned DNA from the region flanking the insertion, a 1477-bp sequence (designated RS1100) wa...

  7. Peculiarities of welding procedure for the 05Kh12K14N5M5T-VD maraging stainless steel with strength higher 1500 MPa

    International Nuclear Information System (INIS)

    Pustovit, A.I.

    1980-01-01

    The effect of welding procedure of 05Kh12K14N5M5T-VD stainless steel on the properties of its welded joints is investigated. A new procedure of welding for pressure vessels made of this steel using Sv-03Kh15K14N5M3T-EL welding wire is suggested [ru

  8. Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy.

    Science.gov (United States)

    Kang, Xin; Cannie, Mieke M; Arthurs, Owen J; Segers, Valerie; Fourneau, Catherine; Bevilacqua, Elisa; Cos Sanchez, Teresa; Sebire, Neil J; Jani, Jacques C

    2017-08-01

    To prospectively compare diagnostic accuracy of fetal post-mortem whole-body MRI at 3-T vs. 1.5-T. Between 2012 and 2015, post-mortem MRI at 1.5-T and 3-T was performed in fetuses after miscarriage/stillbirth or termination. Clinical MRI diagnoses were assessed using a confidence diagnostic score and compared with classical autopsy to derive a diagnostic error score. The relation of diagnostic error for each organ group with gestational age was calculated and 1.5-T with 3-T was compared with accuracy analysis. 135 fetuses at 12-41 weeks underwent post-mortem MRI (followed by conventional autopsy in 92 fetuses). For all organ groups except the brain, and for both modalities, the diagnostic error decreased with gestation (P autopsy than 1.5-T MRI, especially for the thorax, heart and abdomen in fetuses autopsy increases with 3-T. • PM-MRI using 3-T is particularly interesting for thoracic and abdominal organs. • PM-MRI using 3-T is particularly interesting for fetuses < 20 weeks' gestation.

  9. 26 CFR 1.6033-5T - Disclosure by tax-exempt entities that are parties to certain reportable transactions (temporary).

    Science.gov (United States)

    2010-04-01

    ...), including a fully self-directed qualified plan, IRA, or other savings arrangement, the disclosure required... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Disclosure by tax-exempt entities that are... Information Returns § 1.6033-5T Disclosure by tax-exempt entities that are parties to certain reportable...

  10. Residues in blackcurrants, fodder peas, spinach and potatoes treated with sublethal doses of 2,4,5-T to simulate wind drift damage

    DEFF Research Database (Denmark)

    Løkke, Hans; Odgaard, Peder

    1981-01-01

    concentrations declined in the same period due to growth dilution. In spinach leaves from old plants, treated with 0.1 kg ha-1, 0.05 mg of 2,4,5-T kg-1 was found 14 days after treatment. Fodder peas showed no residues (

  11. Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.

    Science.gov (United States)

    Wagner, Franca; Wimmer, Wilhelm; Leidolt, Lars; Vischer, Mattheus; Weder, Stefan; Wiest, Roland; Mantokoudis, Georgios; Caversaccio, Marco D

    2015-01-01

    Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images. MR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal. The results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.

  12. Performance Comparison of 1.5 T Endorectal Coil MRI with Non-Endorectal Coil 3.0 T MRI in Patients with Prostate Cancer

    Science.gov (United States)

    Shah, Zarine K.; Elias, Saba N.; Abaza, Ronney; Zynger, Debra L.; DeRenne, Lawrence A.; Knopp, Michael V.; Guo, Beibei; Schurr, Ryan; Heymsfield, Steven B.; Jia, Guang

    2015-01-01

    Rationale and Objectives To compare prostate morphology, image quality, and diagnostic performance of 1.5 T endorectal coil MRI and 3.0 T non-endorectal coil MRI in patients with prostate cancer. Materials and Methods MR images obtained of 83 patients with prostate cancer using 1.5 T MRI systems with an endorectal coil were compared to images collected from 83 patients with a 3.0 T MRI system. Prostate diameters were measured and image quality was evaluated by one ABR-certified radiologist (Reader 1) and one ABR-certified diagnostic medical physicist (Reader 2). The likelihood of the peripheral zone cancer presence in each sextant and local extent were rated and compared with histopathologic findings. Results Prostate anterior-posterior diameter measured by both readers was significantly shorter with 1.5 T endorectal MRI than with 3.0 T MRI. The overall image quality score difference was significant only for Reader 1. Both readers found that the two MRI systems provided similar diagnostic accuracy in cancer localization, extraprostatic extension, and seminal vesicle involvement. Conclusion Non-endorectal coil 3.0 T MRI provides prostate images that are natural in shape and that have comparable image quality to those obtained at 1.5 T with an endorectal coil, but not superior diagnostic performance. These findings suggest an opportunity exists for improving technical aspects of 3.0 T prostate MRI. PMID:25579637

  13. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  14. Cardiac MR tagging: optimization of sequence parameters and comparison at 1.5 T and 3.0 T in a volunteer study

    International Nuclear Information System (INIS)

    Kramer, U.; Fenchel, M.; Klumpp, B.; Claussen, C.D.; Miller, S.; Deshpande, V.; Laub, G.; Finn, J.P.

    2006-01-01

    Purpose: The aim of this study was the optimization of a gradient echo (GRE) MR tagging sequence at 3.0 T in comparison to 1.5 T in order to obtain the best image contrast between the myocardium, tag lines and blood signal. Theoretically expected improvements of signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were also calculated. Materials and methods: 14 healthy volunteers (8 male, 6 female; mean age 43.4±10.3 years) were scanned using a 3.0 T as well as a 1.5 T whole-body system. A GRE flash-2 D tagging sequence was evaluated (midventricular short axis view) by varying the flip angle (8-16 ), slice thickness (4-8 mm; fixed flip angle 1.5/3.0 T: 12 /8 , tag size 8 mm) and tag size (4-8 mm, fixed flip angle 1.5/3.0 T: 12 /8 , slice thickness 6 mm). The field of view, acquisition time and temporal resolution (45 ms) were kept constant. Qualitative and quantitative image analysis was performed by calculating the SNR, CNR tag as well as the relative contrast between the myocardium and tag lines (RCMT). Results: Based on individual comparison, the best imaging protocol was found at a slice thickness of 6 mm, tag size of 8 mm, optimized flip angle of 8 (3.0 T) and 12 (1.5 T), respectively. Compared to 1.5 T, a significantly higher overall image score was determined (mean±sd; 3.2±0.2 vs 2.7±0.4) and a strong correlation between the CNR tag and RCMT for flip angle α and the slice thickness was found. A higher field strength resulted in an 80% increase in the CNR tag compared to 1.5 T (mean 10.7/6.1). Furthermore, the SNR was improved by 35% (mean 20.6/15.3) and the RCMT by 35% (mean 0.47/0.35). Conclusion: Myocardial tagging at 3.0 T has shown superior image quality in comparison to 1.5 T due to a higher baseline SNR and an improved CNR as well as RCMT. The suppressed fading of the tags enables the accessibility to the diastolic phase of the cardiac cycle. (orig.)

  15. Ex vivo evaluation of ferromagnetism for metallic ocular and middle-ear prostheses exposed to a 1.5-T MR imager

    International Nuclear Information System (INIS)

    Shellock, F.G.; Schatz, C.; Shelton, C.; Brown, B.

    1990-01-01

    This paper determines ferromagnetism by measuring deflection angles for nine different metallic ocular and middle-ear biomedical implants exposed to a 1.5-T MR imager. Deflection angles were determined at the bore of a 1.5-t MR imager for two ocular (Fatio eyelid wire 0.008, Fatio eyelid wire 0.01) and seven middle-ear (House tantalum single loop, House tantalum double loop, IRP, Schuknecht tef-wire piston, Austin tytan piston, McGee piston, Robinson stapes prosthesis) biomedical implants. A previously described, standardized methodology was used to measure deflection angles. Deflection angles for the biomedical implants were 90 degrees for the first ocular implant, over 90 degrees for the second, and 0 degrees (no deflection measured) for the seven middle-ear implants

  16. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    Science.gov (United States)

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  17. Reconstruction of white matter fibre tracts using diffusion kurtosis tensor imaging at 1.5T: Pre-surgical planning in patients with gliomas.

    Science.gov (United States)

    Leote, Joao; Nunes, Rita G; Cerqueira, Luis; Loução, Ricardo; Ferreira, Hugo A

    2018-01-01

    Tractography studies for pre-surgical planning of primary brain tumors is typically done using diffusion tensor imaging (DTI), which cannot resolve crossing, kissing or highly angulated fibres. Tractography based on the estimation of the diffusion kurtosis (DK) tensor was recently demonstrated to enable tackling these limitations. However, its use in the clinical context at low 1.5T field has not yet been reported. To evaluate if the estimation of whole-brain tractography using the DK tensor is feasible for pre-surgical investigation of patients with brain tumors at 1.5T. Eight healthy subjects and 3 patients with brain tumors were scanned at 1.5T using a 12-channel head coil. Diffusion-weighted images were acquired with repetition/echo times of 5800/107 ms, 82 × 82 resolution, 3 × 3 × 3 mm 3 voxel size, b-values of 0, 1000, 2000 s/mm 2 and 64 gradient sensitising directions. Whole-brain tractography was estimated using the DK tensor and corticospinal tracts (CST) were isolated using regions-of-interest placed at the cerebral peduncles and motor gyrus. Tract size, DK metrics and CST deviation index (highest curvature point) were compared between healthy subjects and patients. Tract sizes did not differ between groups. The CST deviation index was significantly higher in patients compared to healthy subjects. Fractional anisotropy was significantly lower in patients, with higher mean kurtosis asymmetry index at the highest curvature point in patients. Corticospinal fibre bundles estimated using DK tensor in a 1.5T scanner presented similar properties in patients with brain gliomas as those reported in the literature using DTI-based tractography.

  18. Analysis of the contribution of -5t/c polymorphism in the GP1BA gene to the development of ischemic stroke in young patients

    Directory of Open Access Journals (Sweden)

    V I Skvortsova

    2012-01-01

    Full Text Available The impact of -5T/C polymorphism in the GP1BA gene on the risk of ischemic stroke (IS was studied in patients younger than 50 years of age. Ninety-two patients (73 men and 19 women; mean age 42.6+6.7years with atherothrombotic, lacunar, and cryptogenic IS were examined on days 1—21 after its development. All the patients underwent brain magnetic resonance imaging or computed tomography, brachiocephalic artery duplex scanning, echocardiography, and laboratory studies (antiphospholipid antibodies, coagulogram and platelet aggregation, homocysteine, clinical and biochemical blood analyses, rheumatic tests, determination of -5T/C polymorphism in the GP1BA gene. An increased risk for IS was found in the young males versus the controls (healthy individuals; p = 0.03; OR 2.7; CI 1.14; 6.47. This association was not found in the women. Analysis of pathogenetic types ascertained that the lacunar IS men with CC and CT genotypes had a higher risk for stroke than the healthy individuals (p = 0.04, OR 3.5, CI 1.1; 10.9. In other subtypes of stroke, there was no association with this polymorphism. A group of patients with IS caused by thrombosis of the great arteries of the brain. In this group, the patients had CC and CT genotypes significantly more frequently than the controls (p = 0.003; OR 6.7; CI 2.0; 21.8, as well as C allele (p = 0.0008; OR 5.1; CI 1.97; 13.3. The -5T/C polymorphism in the GP1BA gene was associated with the development of IS in young males. The -5C allele and -5T/C and -5C/C genotypes are increased risk factors for lacunar and arterial thrombosis-induced IS in men.

  19. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mürtz, P., E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Kaschner, M., E-mail: Marius.Kaschner@med.uni-duesseldorf.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Lakghomi, A., E-mail: Asadeh.Lakghomi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Gieseke, J., E-mail: juergen.gieseke@ukb.uni-bonn.de [Philips Healthcare, Lübeckertordamm 5, 20099 Hamburg (Germany); Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Willinek, W.A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Schild, H.H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Thomas, D., E-mail: daniel.thomas@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany)

    2015-04-15

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus.

  20. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    International Nuclear Information System (INIS)

    Mürtz, P.; Kaschner, M.; Lakghomi, A.; Gieseke, J.; Willinek, W.A.; Schild, H.H.; Thomas, D.

    2015-01-01

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus

  1. Treatment of hepatocellular carcinoma adjacent to large blood vessels using 1.5T MRI-guided percutaneous radiofrequency ablation combined with iodine-125 radioactive seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Zheng-Yu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Chen, Jin, E-mail: snow8968851@163.com [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Deng, Xiu-Fen, E-mail: dxf197286@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2012-11-15

    Objective: The objective is to study the technology associated with and feasibility of the treatment of hepatocellular carcinoma (HCC) adjacent to large blood vessels using 1.5T MRI-guided radiofrequency ablation combined with iodine-125 (I-125) radioactive seed implantation. Methods: Sixteen patients with a total of 24 HCC lesions (average maximum diameter: 2.35 {+-} 1.03 cm) were pathologically confirmed by biopsy or clinically diagnosed received 1.5T MRI-guided percutaneous radiofrequency ablation (RFA) treatment. Each patient had one lesion adjacent to large blood vessels ({>=}3 mm); after the ablation, I-125 radioactive seeds were implanted in the portions of the lesions that were adjacent to the blood vessels. Results: All the ablations and I-125 radioactive seed implantations were successful; a total of 118 seeds were implanted. The ablated lesions exhibited hypointense signals on the T2WI sequence with a thin rim of hyperintense signals; they also exhibited significant hyperintense signals on the T1WI sequence with clear boundaries. The average follow-up period was 11.1 {+-} 6.2 months. There were 23 complete responses and one partial response in the 24 lesions. The alpha-fetoprotein (AFP) levels of the patients significantly decreased. Conclusion: The 1.5T MRI-guided RFA combined with I-125 radioactive seed implantation for the treatment of HCC adjacent to large blood vessels is an effective technology.

  2. In vitro assessment of MRI safety at 1.5 T and 3.0 T for bone-anchored hearing aid implant

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyoo Jin; KIm, Hyun Soo; Lee, Seung Keun [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Tae Soo [Dept. of Biomedical Engineering, Chungbuk National University, Cheongju (Korea, Republic of)

    2017-03-15

    The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with 45° intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with CuSO4 solution. And then the artifact size was measured using Susceptibility Artifact Measurement (SAM) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

  3. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    International Nuclear Information System (INIS)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H.; Walter, Oliver; Gieseke, Juergen

    2007-01-01

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  4. In vitro assessment of MRI safety at 1.5 T and 3.0 T for bone-anchored hearing aid implant

    International Nuclear Information System (INIS)

    Yeon, Kyoo Jin; KIm, Hyun Soo; Lee, Seung Keun; Lee, Tae Soo

    2017-01-01

    The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with 45° intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with CuSO4 solution. And then the artifact size was measured using Susceptibility Artifact Measurement (SAM) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment

  5. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Walter, Oliver [Leibniz-Institute for Science Education, Kiel (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Hamburg (Germany)

    2007-05-15

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  6. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment

    Science.gov (United States)

    Raaymakers, B. W.; Jürgenliemk-Schulz, I. M.; Bol, G. H.; Glitzner, M.; Kotte, A. N. T. J.; van Asselen, B.; de Boer, J. C. J.; Bluemink, J. J.; Hackett, S. L.; Moerland, M. A.; Woodings, S. J.; Wolthaus, J. W. H.; van Zijp, H. M.; Philippens, M. E. P.; Tijssen, R.; Kok, J. G. M.; de Groot-van Breugel, E. N.; Kiekebosch, I.; Meijers, L. T. C.; Nomden, C. N.; Sikkes, G. G.; Doornaert, P. A. H.; Eppinga, W. S. C.; Kasperts, N.; Kerkmeijer, L. G. W.; Tersteeg, J. H. A.; Brown, K. J.; Pais, B.; Woodhead, P.; Lagendijk, J. J. W.

    2017-12-01

    The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.

  7. Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Mandell, Jacob C.; Rhodes, Jeffrey A.; Shah, Nehal; Gaviola, Glenn C.; Smith, Stacy E. [Brigham and Women' s Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Gomoll, Andreas H. [Brigham and Women' s Hospital, Cartilage Repair Center, Department of Orthopedic Surgery, Boston, MA (United States)

    2017-11-15

    Accurate assessment of knee articular cartilage is clinically important. Although 3.0 Tesla (T) MRI is reported to offer improved diagnostic performance, literature regarding the clinical impact of MRI field strength is lacking. The purpose of this study is to compare the diagnostic performance of clinical MRI reports for assessment of cartilage at 1.5 and 3.0 T in comparison to arthroscopy. This IRB-approved retrospective study consisted of 300 consecutive knees in 297 patients who had routine clinical MRI and arthroscopy. Descriptions of cartilage from MRI reports of 165 knees at 1.5 T and 135 at 3.0 T were compared with arthroscopy. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade of the arthroscopic grading were calculated for each articular surface at 1.5 and 3.0 T. Agreement between MRI and arthroscopy was calculated with the weighted-kappa statistic. Significance testing was performed utilizing the z-test after bootstrapping to obtain the standard error. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade were 61.4%, 82.7%, 62.2%, and 77.5% at 1.5 T and 61.8%, 80.6%, 59.5%, and 75.6% at 3.0 T, respectively. The weighted kappa statistic was 0.56 at 1.5 T and 0.55 at 3.0 T. There was no statistically significant difference in any of these parameters between 1.5 and 3.0 T. Factors potentially contributing to the lack of diagnostic advantage of 3.0 T MRI are discussed. (orig.)

  8. MR imaging of hyaline cartilage at 0.5 T: a quantitative and qualitative in vitro evaluation of three types of sequences

    International Nuclear Information System (INIS)

    Linden, E. van der; Kroon, H.M.; Doornbos, J.; Bloem, J.L.; Hermans, J.

    1998-01-01

    Objective. To identify an optimal pulse sequence for in vitro imaging of hyaline cartilage at 0.5 T. Materials and methods. Twelve holes of varying diameter and depth were drilled in cartilage of two pig knees. These were submerged in saline and scanned with a 0.5-T MR system. Sixteen T1-weighted gradient echo (GE), two T2-weighted GE, and 16 fast spin echo sequences were used, by varying repetition time (TR), echo time (TE), flip angle (FA), echo train length, profile order, and by use of fat saturation. Contrast-to-noise ratios (CNR) of cartilage versus saline solution and cartilage versus subchondral bone were measured. Cartilaginous lesions were evaluated separately by three independent observers. Interobserver variability and correlation between the quantitative and qualitative analyses were calculated. Results. The mean CNRs of two specimens of cartilage versus saline solution ranged from 6.3 (±2.1) to 27.7 (±2.5), and those of cartilage versus subchondral bone from 0.3 (±0.2) to 22.5 (±1.4). The highest CNR was obtained with a T1-weighted spoiled 3D-GE technique (TR 65 ms, TE 11.5 ms, FA 45 ). The number of lesions observed per sequence varied from 35 to 69. Observer agreement was fair to good. The T1-weighted spoiled GE sequences with a TR of 65 ms, TE of 11.5 ms and FA of 30 and 45 were significantly superior to the other 34 sequences in the qualitative analysis. Conclusion. T1-weighted spoiled 3D-GE sequences with a TR of 65 ms, a TE of 11.5 ms, and a FA of 30-45 were found to be optimal for in vitro imaging of cartilage at 0.5 T. (orig.)

  9. MR imaging of hyaline cartilage at 0.5 T: a quantitative and qualitative in vitro evaluation of three types of sequences

    Energy Technology Data Exchange (ETDEWEB)

    Linden, E. van der; Kroon, H.M.; Doornbos, J.; Bloem, J.L. [Department of Radiology C2-S, Albinusdreef 2, Leiden University Medical Center, Postbus 9600, NL-2300 RC Leiden (Netherlands); Hermans, J. [Department of Medical Statistics, Leiden University Medical Center, Leiden (Netherlands)

    1998-06-01

    Objective. To identify an optimal pulse sequence for in vitro imaging of hyaline cartilage at 0.5 T. Materials and methods. Twelve holes of varying diameter and depth were drilled in cartilage of two pig knees. These were submerged in saline and scanned with a 0.5-T MR system. Sixteen T1-weighted gradient echo (GE), two T2-weighted GE, and 16 fast spin echo sequences were used, by varying repetition time (TR), echo time (TE), flip angle (FA), echo train length, profile order, and by use of fat saturation. Contrast-to-noise ratios (CNR) of cartilage versus saline solution and cartilage versus subchondral bone were measured. Cartilaginous lesions were evaluated separately by three independent observers. Interobserver variability and correlation between the quantitative and qualitative analyses were calculated. Results. The mean CNRs of two specimens of cartilage versus saline solution ranged from 6.3 ({+-}2.1) to 27.7 ({+-}2.5), and those of cartilage versus subchondral bone from 0.3 ({+-}0.2) to 22.5 ({+-}1.4). The highest CNR was obtained with a T1-weighted spoiled 3D-GE technique (TR 65 ms, TE 11.5 ms, FA 45 ). The number of lesions observed per sequence varied from 35 to 69. Observer agreement was fair to good. The T1-weighted spoiled GE sequences with a TR of 65 ms, TE of 11.5 ms and FA of 30 and 45 were significantly superior to the other 34 sequences in the qualitative analysis. Conclusion. T1-weighted spoiled 3D-GE sequences with a TR of 65 ms, a TE of 11.5 ms, and a FA of 30-45 were found to be optimal for in vitro imaging of cartilage at 0.5 T. (orig.) With 8 figs., 1 tab., 31 refs.

  10. BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T

    International Nuclear Information System (INIS)

    Landuyt, W.; Bogaert, W. van den; Lambin, P.; Hermans, R.; Bosmans, H.; Sunaert, S.; Beatse, E.; Farina, D.; Meijerink, M.; Zhang, H.; Marchal, G.

    2001-01-01

    The aim of this study was to evaluate the feasibility of functional MR imaging (fMRI) at 1.5 T, exploiting blood oxygenation level-dependent (BOLD) contrast, for detecting changes in whole-tumour oxygenation induced by carbogen (5% CO 2 +95% O 2 ) inhalation of the host. Adult WAG/Rij rats with rhabdomyosarcomas growing subcutaneously in the lower flank were imaged when tumours reached sizes between 1 and 11 cm 3 (n=12). Air and carbogen were alternatively supplied at 2 l/min using a snout mask. Imaging was done on a 1.5-T MR scanner using a T2*-weighted gradient-echo, echo-planar imaging (GE-EPI) sequence. Analysis of the whole-tumour EPI images was based on statistical parametric maps. Voxels with and without signal intensity changes (SIC) were recorded. Significance thresholds were set at p<0.05, corrected for multiple comparisons. In continuous air breathing condition, 3 of 12 tumours showed significant negative SIC and 1 tumour had a clear-cut positive SIC. The remaining tumours showed very little or no change. When switching to carbogen breathing, the SIC were significantly positive in 10 of 12 tumours. Negative SIC were present in 4 tumours, of which three were simultaneously characterised by positive SIC. The overall analysis indicated that 6 of the 12 tumours could be considered as strong positive responders to carbogen. Our research demonstrates the applicability of fMRI GE-EPI at 1.5 T to study whole-tumour oxygenation non-invasively. The observed negative SIC during air condition may reflect the presence of transient hypoxia during these measurements. Selection of tumours on the basis of their individual response to carbogen is possible, indicating a role of such non-invasive measurements for using tailor-made treatments. (orig.)

  11. Breast MRI at 3.0 T in a high-risk familial breast cancer screening cohort: comparison with 1.5 T screening studies.

    Science.gov (United States)

    Pickles, M D; Turnbull, L W

    2012-07-01

    The sensitivity of X-ray mammography for the detection of breast malignancy in younger females is lower than that of breast MRI; consequently, guidelines recommend annual MRI for patients with a significantly elevated lifetime risk. The improved signal-to-noise ratio obtainable at 3.0 T should result in data superior to those obtainable at 1.5 T. However, breast imaging on higher field strength systems poses specific problems. As a result, caution has been urged in the implementation of breast MRI at 3.0 T. The aim of this study was to determine if it is appropriate to use 3.0 T MRI in the screening of patients by comparing the summary statistics achieved by this 3.0 T MRI programme against the published results of 1.5 T screening studies. Over a 20-month period, 291 patients referred with an elevated familial risk of breast cancer were examined at 3.0 T. Resulting images were scored based on the Royal College of Radiologists Breast Group imaging classification. The reference standard was a combination of histology and follow-up imaging. Follow-up data were available in 267 patients. Analysis revealed positive and negative post-test probabilities of 28% [95% confidence intervals (CI); range, 10-60%] and 1% (95% CI; range, 0-2%), respectively. These results compared favourably against those of a recent meta-analysis [25.3% (95% CI; range, 18.4-33.8%) and 0.4% (95% CI; range, 0.2-0.9%), respectively]. Given the similar summary statistics between this work and the 1.5 T results, it would appear that screening of high-risk patients at 3.0 T has potential. Further studies should be undertaken to verify this result.

  12. Electrochemical decontamination of waters by advanced oxidation processes (aops): Case of the mineralization of 2,4,5-t on bdd electrode

    OpenAIRE

    Birame Boye; Enric Brillas; Beatrice Marselli; Pierre-Alain Michaud; Christos Comninellis; Mor Marième Dieng

    2004-01-01

    In the present work, herbicide 2,4,5-trichlorophenoxyacetic acid, more commonly known as 2,4,5-T herbicide, has been completely mineralized (i.e. transformed into CO2 and H2O) in saturated aqueous solutions using a semi-industrial electrochemical cell that contains a boron doped diamond anode and a zirconium cathode. We have performed cyclic voltammetry, chronoamperometry and bulk electrolysis to give the optimization characteristics of the degradation of such a compound and its by-products. ...

  13. Electrochemical decontamination of waters by advanced oxidation processes (aops: Case of the mineralization of 2,4,5-t on bdd electrode

    Directory of Open Access Journals (Sweden)

    Birame Boye

    2004-12-01

    Full Text Available In the present work, herbicide 2,4,5-trichlorophenoxyacetic acid, more commonly known as 2,4,5-T herbicide, has been completely mineralized (i.e. transformed into CO2 and H2O in saturated aqueous solutions using a semi-industrial electrochemical cell that contains a boron doped diamond anode and a zirconium cathode. We have performed cyclic voltammetry, chronoamperometry and bulk electrolysis to give the optimization characteristics of the degradation of such a compound and its by-products. Bulk electrolysis in the potential region of electrolyte decomposition leads to the complete destruction of 2,4,5-T and its degradation intermediates by means of the electrogeneration of the highly reactive hydroxyl radicals. The evolution of the chemical oxygen demand (COD and the instant current efficiency (ICE during the degradation process is perfectly predicted by a theoretical mathematical model. HPLC and GC-MS have also been performed to highlight the evolution of the mother product and its degradation intermediates. Kinetic analysis of the obtained results has shown a fast destruction of the mother herbicide asserting a diffusion-controlled process. 2,4,5-trichlorophenol and quinone-based organic compounds have been depicted as aromatic intermediates, all of them transformed into short chains carboxylic acids before complete mineralization happens.

  14. High-resolution MR imaging of the elbow using a microscopy surface coil and a clinical 1.5 T MR machine: preliminary results

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Ueno, Teruko; Takahashi, Nobuyuki; Saida, Yukihisa; Tanaka, Toshikazu; Kujiraoka, Yuka; Shindo, Masashi; Nishiura, Yasumasa; Ochiai, Naoyuki

    2004-01-01

    To obtain high-resolution MR images of the elbow using a microscopy surface coil with a 1.5 T clinical machine and to evaluate the feasibility of its use for elbow injuries. Five asymptomatic normal volunteers and 13 patients with elbow pain were prospectively studied with MR imaging using a microscopy surface coil 47 mm in diameter. High-resolution MR images using a microscopy coil were obtained with fast spin echo (FSE) proton density-weighted sequence, gradient recalled echo (GRE) T2*-weighted sequence, and short tau inversion recovery (STIR) sequence, with a 1-2 mm slice thickness, a 50-70 mm field of view, an imaging matrix of 140-224 x 512 using zero fill interpolation, and 2-6 excitations. High-resolution MR images of normal volunteers using a microscopy coil clearly showed each structure of the medial and lateral collateral ligaments on GRE T2*-weighted images and FSE proton-density weighted images. Partial medial collateral ligament injury, a small avulsion of the medial epicondyle, and osteochondritis dissecans were well demonstrated on high-resolution MR images. High-resolution MR imaging of the elbow using a microscopy surface coil with a 1.5 T clinical machine is a promising method for accurately characterizing the normal anatomy of the elbow and depicting its lesions in detail. (orig.)

  15. 3D Whole-Heart Coronary MR Angiography at 1.5T in Healthy Volunteers: Comparison between Unenhanced SSFP and Gd-Enhanced FLASH Sequences

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Lee, Sang Min; Hong, Yoo Jin; Kim, Tae Hoon

    2011-01-01

    To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). Thirty healthy volunteers (M:F 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.

  16. Reproducibility of MR-based liver fat quantification across field strength: Same-day comparison between 1.5T and 3T in obese subjects.

    Science.gov (United States)

    Artz, Nathan S; Haufe, William M; Hooker, Catherine A; Hamilton, Gavin; Wolfson, Tanya; Campos, Guilherme M; Gamst, Anthony C; Schwimmer, Jeffrey B; Sirlin, Claude B; Reeder, Scott B

    2015-09-01

    To examine the reproducibility of quantitative magnetic resonance (MR) methods to estimate hepatic proton density fat-fraction (PDFF) at different magnetic field strengths. This Health Insurance Portability and Accountability Act (HIPAA)-compliant study was approved by the Institutional Review Board. Following informed consent, 25 severely obese subjects (mean body mass index [BMI]: 45 ± 4, range: 38-53 kg/m(2) ) were scanned at 1.5T and 3T on the same day. Two confounder-corrected multiecho chemical shift-encoded gradient-echo-based imaging methods were acquired to estimate PDFF over the entire liver: 3D complex-based (MRI-C) and 2D magnitude-based (MRI-M) MRI. Single-voxel MR spectroscopy (MRS) was performed in the right liver lobe. Using linear regression, pairwise comparisons of estimated PDFF were made between methods (MRI-C, MRI-M, MRS) at each field strength and for each method across field strengths. 1.5T vs. 3T regression analyses for MRI-C, MRI-M, and MRS PDFF measurements yielded R(2) values of 0.99, 0.97, and 0.90, respectively. The best-fit line was near unity (slope(m) = 1, intercept(b) = 0), indicating excellent agreement for each case: MRI-C (m = 0.92 [0.87, 0.99], b = 1.4 [0.7, 1.8]); MRI-M (m = 1.0 [0.90, 1.08], b = -1.4 [-2.4, -0.5]); MRS (m = 0.98 [0.82, 1.15], b = 1.2 [-0.2, 3.0]). Comparing MRI-C and MRI-M yielded an R(2)  = 0.98 (m = 1.1 [1.02, 1.16], b = -1.8 [-2.8, -1.1]) at 1.5T, and R(2)  = 0.99 (m = 0.98 [0.93, 1.03], b = 1.2 [0.7, 1.7]) at 3T. This study demonstrates that PDFF estimation is reproducible across field strengths and across two confounder-corrected MR-based methods. © 2015 Wiley Periodicals, Inc.

  17. Abdominopelvic 1.5-T and 3.0-T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks.

    Science.gov (United States)

    Suntharalingam, Saravanabavaan; Mladenov, Emil; Sarabhai, Theresia; Wetter, Axel; Kraff, Oliver; Quick, Harald H; Forsting, Michael; Iliakis, Georg; Nassenstein, Kai

    2018-05-01

    Purpose To investigate the relationship between abdominopelvic magnetic resonance (MR) imaging and formation of DNA double-strand breaks (DSBs) in peripheral blood lymphocytes among a cohort of healthy volunteers. Materials and Methods Blood samples were obtained from 40 healthy volunteers (23 women and 17 men; mean age, 27.2 years [range, 21-37 years]) directly before and 5 and 30 minutes after abdominopelvic MR imaging performed at 1.5 T (n = 20) or 3.0 T (n = 20). The number of DNA DSBs in isolated blood lymphocytes was quantified after indirect immunofluorescent staining of a generally accepted DSB marker, γ-H2AX, by means of high-throughput automated microscopy. As a positive control of DSB induction, blood lymphocytes from six volunteers were irradiated in vitro with x-rays at a dose of 1 Gy (70-90 keV). Statistical analysis was performed by using a Friedman test. Results No significant alteration in the frequency of DNA DSB induction was observed after MR imaging (before imaging: 0.22 foci per cell, interquartile range [IQR] = 0.54 foci per cell; 5 minutes after MR imaging: 0.08 foci per cell, IQR = 0.39 foci per cell; 30 minutes after MR imaging: 0.09 foci per cell, IQR = 0.63 foci per cell; P = .057). In vitro radiation of lymphocytes with 1 Gy led to a significant increase in DSBs (0.22 vs 3.43 foci per cell; P = .0312). The frequency of DSBs did not differ between imaging at 1.5 T and at 3.0 T (5 minutes after MR imaging: 0.23 vs 0.06 foci per cell, respectively [P = .57]; 30 minutes after MR imaging: 0.12 vs 0.08 foci per cell [P = .76]). Conclusion Abdominopelvic MR imaging performed at 1.5 T or 3.0 T does not affect the formation of DNA DSBs in peripheral blood lymphocytes. © RSNA, 2018.

  18. A little CFTR goes a long way: CFTR-dependent sweat secretion from G551D and R117H-5T cystic fibrosis subjects taking ivacaftor.

    Directory of Open Access Journals (Sweden)

    Jessica E Char

    Full Text Available To determine if oral dosing with the CFTR-potentiator ivacaftor (VX-770, Kalydeco improves CFTR-dependent sweating in CF subjects carrying G551D or R117H-5T mutations, we optically measured sweat secretion from 32-143 individually identified glands in each of 8 CF subjects; 6 F508del/G551D, one G551D/R117H-5T, and one I507del/R117H-5T. Two subjects were tested only (- ivacaftor, 3 only (+ ivacaftor and 3 (+/- ivacaftor (1-5 tests per condition. The total number of gland measurements was 852 (- ivacaftor and 906 (+ ivacaftor. A healthy control was tested 4 times (51 glands. For each gland we measured both CFTR-independent (M-sweat and CFTR-dependent (C-sweat; C-sweat was stimulated with a β-adrenergic cocktail that elevated [cAMP]i while blocking muscarinic receptors. Absent ivacaftor, almost all CF glands produced M-sweat on all tests, but only 1/593 glands produced C-sweat (10 tests, 5 subjects. By contrast, 6/6 subjects (113/342 glands produced C-sweat in the (+ ivacaftor condition, but with large inter-subject differences; 3-74% of glands responded with C/M sweat ratios 0.04%-2.57% of the average WT ratio of 0.265. Sweat volume losses cause proportionally larger underestimates of CFTR function at lower sweat rates. The losses were reduced by measuring C/M ratios in 12 glands from each subject that had the highest M-sweat rates. Remaining losses were estimated from single channel data and used to correct the C/M ratios, giving estimates of CFTR function (+ ivacaftor  = 1.6%-7.7% of the WT average. These estimates are in accord with single channel data and transcript analysis, and suggest that significant clinical benefit can be produced by low levels of CFTR function.

  19. Case study on unusual occurrence of wire rope failure of 15/5t EOT crane at one of the plant, Nuclear Fuel Complex

    International Nuclear Information System (INIS)

    Siddu, P.V.; Subhakar, A.; Devender Rao, D.; Srichandan, T.T.; Harilingam, S.; Mahesh Kumar, V.V.; Kiran Kumar, I.; Thakur, Sudhir

    2016-01-01

    At NFC, Production of fuel bundles and other structural involves a large number of material handling activities for transfer of materials from one plant to another. One of the widely used materials handling equipment at NFC is the Electric Overhead Travelling (EOT) Crane. These EOT cranes will be tested yearly as per the statutory requirements in the presence of the competent person. Also, regular inspection and maintenance activities will be carried by the plant maintenance crew. Even with preventive maintenance and monitoring, there could be accidents due to unsafe conditions, unsafe acts or both. However, all the unusual occurrence, incidents and accidents can be prevented. This paper deals about the unusual occurrence of wire rope failure of 15/5T EOT crane at one of the plant in NFC; recommendations given by the Safety Committee, AERB and action taken by the plant to prevent reoccurrence of unusual occurrence. (author)

  20. SU-F-T-645: To Test Spatial Anddosimetric Accuracy of Small Cranial Target Irradiation Based On 1.5 T MRIscans Using Static Arcs with MLCDefined Fields

    International Nuclear Information System (INIS)

    Brezovich, I; Wu, X; Popple, R; Shen, S; Cardan, R; Bolding, M; Fiveash, J; Kraus, J; Spencer, S

    2016-01-01

    Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer of the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.

  1. Specificity of choline metabolites for in vivo diagnosis of breast cancer using {sup 1}H MRS at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Stanwell, Peter; Gluch, Laurence; Lean, Cynthia; Malycha, Peter; Mountford, Carolyn [Royal North Shore Hospital, Institute for Magnetic Resonance Research and Department of Magnetic Resonance in Medicine, University of Sydney, St Leonards, NSW (Australia); Clark, David [Breast Centre, Waratah, NSW (Australia); Tomanek, Boguslaw [National Research Council Canada, Institute for Biodiagnostics, Winnipeg, MB (Canada); Baker, Luke [Sydney Adventist Hospital, Department of Radiology, Wahroonga, NSW (Australia); Giuffre, Bruno [Royal North Shore Hospital, Department of Radiology, St Leonards, NSW (Australia)

    2005-05-01

    The purpose was to determine if in vivo proton magnetic resonance spectroscopy ({sup 1}H MRS) at 1.5 T can accurately provide the correct pathology of breast disease. Forty-three asymptomatic volunteers including three lactating mothers were examined and compared with 21 breast cancer patients. Examinations were undertaken at 1.5 T using a purpose-built transmit-receive single breast coil. Single voxel spectroscopy was undertaken using echo times of 135 and 350 ms. The broad composite resonance at 3.2 ppm, which includes contributions from choline, phosphocholine (PC), glycerophosphocholine (GPC), myo-inositol and taurine, was found not to be a unique marker for malignancy providing a diagnostic sensitivity and specificity of 80.0 and 86.0%, respectively. This was due to three of the asymptomatic volunteers and all of the lactating mothers also generating the broad composite resonance at 3.2 ppm. Optimised post-acquisitional processing of the spectra resolved a resonance at 3.22 ppm, consistent with PC, in patients with cancer. In contrast the spectra recorded for three false-positive volunteers, and the three lactating mothers had a resonance centred at 3.28 ppm (possibly taurine, myo-inositol or GPC). This improved the specificity of the test to 100%. Careful referencing of the spectra and post-acquisitional processing intended to optimise spectral resolution of in vivo MR proton spectra from human breast tissue resolves the composite choline resonance. This allows the distinction of patients with malignant disease from volunteers with a sensitivity of 80% and specificity of 100%. Therefore, resolution of the composite choline resonance into its constituent components improves the specificity of the in vivo {sup 1}H MRS method, but does not overcome the problem of 20% false-negatives. (orig.)

  2. Detection and differentiation of early acute and following age stages of myocardial infarction with quantitative post-mortem cardiac 1.5T MR.

    Science.gov (United States)

    Schwendener, Nicole; Jackowski, Christian; Persson, Anders; Warntjes, Marcel J; Schuster, Frederick; Riva, Fabiano; Zech, Wolf-Dieter

    2017-01-01

    Recently, quantitative MR sequences have started being used in post-mortem imaging. The goal of the present study was to evaluate if early acute and following age stages of myocardial infarction can be detected and discerned by quantitative 1.5T post-mortem cardiac magnetic resonance (PMCMR) based on quantitative T1, T2 and PD values. In 80 deceased individuals (25 female, 55 male), a cardiac MR quantification sequence was performed prior to cardiac dissection at autopsy in a prospective study. Focal myocardial signal alterations detected in synthetically generated MR images were MR quantified for their T1, T2 and PD values. The locations of signal alteration measurements in PMCMR were targeted at autopsy heart dissection and cardiac tissue specimens were taken for histologic examinations. Quantified signal alterations in PMCMR were correlated to their according histologic age stage of myocardial infarction. In PMCMR seventy-three focal myocardial signal alterations were detected in 49 of 80 investigated hearts. These signal alterations were diagnosed histologically as early acute (n=39), acute (n=14), subacute (n=10) and chronic (n=10) age stages of myocardial infarction. Statistical analysis revealed that based on their quantitative T1, T2 and PD values, a significant difference between all defined age groups of myocardial infarction can be determined. It can be concluded that quantitative 1.5T PMCMR quantification based on quantitative T1, T2 and PD values is feasible for characterization and differentiation of early acute and following age stages of myocardial infarction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Using fMRI to Detect Activation of the Cortical and Subcortical Auditory Centers: Development of a Standard Protocol for a Conventional 1.5-T MRI Scanner

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Kim, Sam Soo; Lee, Kang Uk; Lee, Seung Hwan; Nam, Eui Cheol; Choi, Hyun Kyung

    2009-01-01

    We wanted to develop a standard protocol for auditory functional magnetic resonance imaging (fMRI) for detecting blood oxygenation level-dependent (BOLD) responses at the cortical and subcortical auditory centers with using a 1.5-T MRI scanner. Fourteen normal volunteers were enrolled in the study. The subjects were stimulated by four repetitions of 32 sec each with broadband white noise and silent period blocks as a run (34 echo planar images [EPIs]). Multiple regression analysis for the individual analysis and one-sample t-tests for the group analysis were applied (FDR, p <0.05). The auditory cortex was activated in most of the volunteers (left 100% and right 92.9% at an uncorrected p value <0.05, and left 92.9% and right 92.9% at an uncorreced p value <0.01). The cochlear nuclei (100%, 85.7%), inferior colliculi (71.4%, 64.3%), medial geniculate bodies (64.3%, 35.7%) and superior olivary complexes (35.7%, 35.7%) showed significant BOLD responses at uncorrected p values of <0.05 and p <0.01, respectively. On the group analysis, the cortical and subcortical auditory centers showed significant BOLD responses (FDR, p <0.05), except for the superior olivary complex. The signal intensity time courses of the auditory centers showed biphasic wave forms. We successfully visualized BOLD responses at the cortical and subcortical auditory centers using appropriate sound stimuli and an image acquisition method with a 1.5-T MRI scanner

  4. 31P-MR spectroscopy of all regions of the human heart at 1.5 T with acquisition-weighted chemical shift imaging

    International Nuclear Information System (INIS)

    Koestler, H.; Beer, M.; Buchner, S.; Sandstede, J.; Pabst, T.; Kenn, W.; Hahn, D.

    2001-01-01

    Aim: Aim of this study was to show whether or not acquisition-weighted chemical shift imaging (AW-CSI) allows the determination of PCr and ATP in the lateral and posterior wall of the human heart at 1.5 T. Methods: 12 healthy volunteers were examined using a conventional chemical shift imaging (CSI) and an AW-CSI. The sequences differed only in the number of repetitions for each point in k space. A hanning function was used as filter function leading to 7 repetitions in the center of the k space and 0 in the corners. Thus, AW-CSI had the same resolution as the CSI sequence. The results for both sequences were analyzed using identically positioned voxels in the septal, anterior, lateral and posterior wall. Results: The determined averaged AW-CSI signal to noise ratios were higher for PCr by a factor of 1.3 and for ATP by 1.4 than those of CSI. The PCr/ATP ratios were higher by a factor of 1.2 - 1.3 and showed a smaller standard deviation in all locations for AW-CSI. The mean PCr/ATP ratios determined by AW-CSI of septal, lateral and posterior wall were almost identical (1.72 - 1.76), while it was higher in the anterior wall (1.9). Conclusions: The reduced contamination in AW-CSI improves the signal to noise ratio and the determination of the PCr/ATP ratio in cardiac 31 P spectroscopy compared to CSI with the same resolution. The results in volunteers indicate that AW-CSI renders 31 P spectroscopy of the lateral and posterior wall of the human heart feasible for patient studies at 1.5 T. (orig.) [de

  5. MR imaging characteristics of intracranial hemorrhage using gradient-echo signal acquisition at 1.5 T: Comparison with spin-echo imaging and clinical applications

    International Nuclear Information System (INIS)

    Atlas, S.W.; Grossman, R.I.; Gomori, J.M.; Hackney, D.B.; Goldberg, H.I.; Bilaniuk, L.T.; Zimmerman, R.A.

    1987-01-01

    Evolving paramagnetic blood-breakdown products create static local magnetic susceptibility gradients, which induce rapid phase dispersion on the basis of T2/sup */ shortening. The authors evaluated 30 patients with 50 separate hemorrhagic intracranial lesions with both spin-echo (SE) and gradient echo signal acquisition (GESA) MR imaging at 1.5 T. GESA sequences used repetition time (TR) of 200-750 msec, echo time (TE) of 50-80 msec, and flip angles of 10 0 to 15 0 to emphasize T2/sup */-based contributions to contrast. SE sequences in all cases utilized both short and long TR (600 and 2,500-3,000 msec), with TE of 20-120 msec. Advantages of GESA imaging with Long TE and short flip angles in the evaluation of intracranial hemorrhage include (1) increased sensitivity to susceptibility-induced phase loss from T2/sup */ shortening, resulting in detection of hemorrhagic lesions not seen on conventional long TR/long TE SE images, and (2) very rapid acquisition of images with T2/sup */-based contrast. Limitations of this sequence include (1) severe diamagnetic susceptibility-induced artifacts, especially near air-brain interfaces, which often obscure large portions of the brain and occasionally simulate serious pathology, (2) characteristic internal signal intensity patterns demonstrated by SE imaging, such as in evolving hematomas, occult vascular malformations, and hemorrhagic malignancies, are often obscured by marked hypointensity on GESA images, and (3) reduced signal-noise ratio. The authors conclude that, although images with marked sensitivity to T2/sup */ effects can be rapidly generated by GESA, there is only a limited role for this sequence when evaluating intracranial hemorrhage at 1.5 T, and, in fact, significant information is lost when compared to SE images

  6. T1 and T2 relaxivity of intracellular and extracellular USPIO at 1.5T and 3T clinical MR scanning

    International Nuclear Information System (INIS)

    Simon, Gerhard H.; Bauer, Jan; Saborovski, Olaf; Fu, Yanjun; Wendland, Michael F.; Daldrup-Link, Heike E.; Corot, Claire

    2006-01-01

    In this study we evaluated the effects of intracellular compartmentalization of the ultrasmall superparamagnetic iron oxide (USPIO) ferumoxtran-10 on its proton T1 and T2 relaxivities at 1.5 and 3T. Monocytes were labeled with ferumoxtran-10 by simple incubation. Decreasing quantities of ferumoxtran-10-labeled cells (2.5 x 10 7 -0.3 x 10 7 cells/ml) and decreasing concentrations of free ferumoxtran-10 (without cells) in Ficoll solution were evaluated with 1.5 and 3T clinical magnetic resonance (MR) scanners. Pulse sequences comprised axial spin echo (SE) sequences with multiple TRs and fixed TE and SE sequences with fixed TR and increasing TEs. Signal intensity measurements were used to calculate T1 and T2 relaxation times of all samples, assuming a monoexponential signal decay. The iron content in all samples was determined by inductively coupled plasma atomic emission spectrometry and used for calculating relaxivities. Measurements at 1.5T and 3T showed higher T1 and T2 relaxivity values of free extracellular ferumoxtran-10 as opposed to intracellularly compartmentalized ferumoxtran-10, under the evaluated conditions of homogeneously dispersed contrast agents/cells in Ficoll solution and a cell density of up to 2.5 x 10 7 cells/ml. At 3T, differences in T1-relaxivities between intra- and extracellular USPIO were smaller, while differences in USPIO T2-relaxivities were similar compared with 1.5T. In conclusion, cellular compartmentalization of ferumoxtran-10 changes proton relaxivity. (orig.)

  7. 3,5-Diiodo-L-thyronine (3,5-t2) exerts thyromimetic effects on hypothalamus-pituitary-thyroid axis, body composition, and energy metabolism in male diet-induced obese mice.

    Science.gov (United States)

    Jonas, Wenke; Lietzow, Julika; Wohlgemuth, Franziska; Hoefig, Carolin S; Wiedmer, Petra; Schweizer, Ulrich; Köhrle, Josef; Schürmann, Annette

    2015-01-01

    Effective and safe antiobesity drugs are still needed in face of the obesity pandemic worldwide. Recent interventions in rodents revealed 3,5-diiodo-L-thyronine (3,5-T2) as a metabolically active iodothyronine affecting energy and lipid metabolism without thyromimetic side effects typically associated with T3 administration. Accordingly, 3,5-T2 has been proposed as a potential hypolipidemic agent for treatment of obesity and hepatic steatosis. In contrast to other observations, our experiments revealed dose-dependent thyromimetic effects of 3,5-T2 akin to those of T3 in diet-induced obese male C57BL/6J mice. 3,5-T2 treatment exerted a negative feedback regulation on the hypothalamus-pituitary-thyroid axis, similar to T3. This is demonstrated by decreased expression of genes responsive to thyroid hormones (TH) in pituitary resulting in a suppressed thyroid function with lower T4 and T3 concentrations in serum and liver of 3,5-T2-treated mice. Analyses of hepatic TH target genes involved in lipid metabolism revealed T3-like changes in gene expression and increased type I-deiodinase activity after application of 3,5-T2 (2.5 μg/g body weight). Reduced hepatic triglyceride and serum cholesterol concentrations reflected enhanced lipid metabolism. Desired increased metabolic rate and reduction of different fat depots were, however, compromised by increased food intake preventing significant body weight loss. Moreover, enlarged heart weights indicate potential cardiac side effects of 3,5-T2 beyond hepatic thyromimetic actions. Altogether, the observed thyromimetic effects of 3,5-T2 in several mouse TH target tissues raise concern about indiscriminate administration of 3,5-T2 as powerful natural hormone for the treatment of hyperlipidemia and pandemic obesity.

  8. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  9. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  10. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  11. Relativistic band-structure calculations for CeTIn sub 5 (T=Ir and Co) and analysis of the energy bands by using tight-binding method

    CERN Document Server

    Maehira, T; Ueda, K; Hasegawa, A

    2003-01-01

    In order to investigate electronic properties of recently discovered heavy fermion superconductors CeTIn sub 5 (T=Ir and Co), we employ the relativistic linear augmented-plane-wave (RLAPW) method to clarify the energy band structures and Fermi surfaces of those materials. The obtained energy bands mainly due to the large hybridization between Ce 4 f and In 5 p states well reproduce the Fermi surfaces consistent with the de Haas-van Alphen experimental results. However, when we attempt to understand magnetism and superconductively in CeTIn sub 5 from the microscopic viewpoint, the energy bands obtained in the RLAPW method are too complicated to analyze the system by further including electron correlations. Thus, it is necessary to prepare a more simplified model, keeping correctly the essential characters of the energy bands obtained in the band-structure calculation. For the purpose, we construct a tight-binding model for CeTIn sub 5 by including f-f and p-p hoppings as well as f-p hybridization, which are ex...

  12. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T.; Leinung, S.; Briest, S.

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions ( [de

  13. An investigation of cerebral magnetic resonance angiography (MRA). Part 8: diagnostic ability of cerebral aneurysms with MRA using 1.5 T MRI

    International Nuclear Information System (INIS)

    Ohue, Shiro; Kusunoki, Katsusuke; Kohno, Kanehisa

    1998-01-01

    The ability of MR angiography (MRA) to detect intracranial aneurysms was assessed. Seventy-eight patients, including 21 cases of intracranial aneurysms, underwent three-dimensional time-of-flight (3D TOF) MRA using a 1.5 T MRI system. MRA images were evaluated using maximum intensity projection (MIP) images only, MIP+selective MIP images, and MIP+selective MIP+original images by ten neurosurgeons and neuroradiologists. By receiver operating characteristic (ROC) analysis of the ability to detect the 21 patients with aneurysms, the sensitivity of MIP images was 74±8% (mean±S.D.) while the specificity was 80%. Of 26 aneurysms, the sensitivity of MIP images was 64±9% (mean±S.D.). Although the sensitivity for aneurysms 5 mm or larger, or located at middle cerebral arteries was over 85%, the sensitivity for aneurysms smaller than 5 mm or located at internal carotid arteries was less than 50%. The evaluation of MRA adding selective MIP and original images to MIP images improved the sensitivity in detecting aneurysms and decreased the number of false positive cases. These data indicate that MRA is a useful technique for detecting aneurysms 5 mm or larger, and those located at the middle cerebral arteries. However, by MRA, it remains difficult to detect aneurysms smaller than 5 mm and those located at the internal carotid arteries. (author)

  14. Invasive placenta previa. Placental bulge with distorted uterine outline and uterine serosal hypervascularity at 1.5T MRI - useful features for differentiating placenta percreta from placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xin; Zhang, Xinjuan; Wang, Shanshan; Shi, Honglu; Gao, Fei; Wang, Guangbin [Shandong University, Department of MR, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Shan, Ruiqin [Jinan Maternity and Child Care Hospital, Department of Obstetrics, Jinan (China); Zhao, Lianxin [Qilu Hospital of Shandong University, Department of Radiology, Jinan, Shandong (China); Song, Qingxu [Qilu Hospital of Shandong University, Department of Radiation Oncology, Jinan, Shandong (China); Zuo, Changting [Shandong Provincial Hospital Affiliated to Shandong University, Department of Obstetrics and Gynaecology, Jinan, Shandong (China); Qian, Tianyi [MR Collaborations NE Asia, Siemens Healthcare, Beijing (China); Limperopoulos, Catherine [Children' s National Health System, Division of Diagnostic Imaging and Radiology, Washington, DC (United States); George Washington University School of Medicine, Department of Radiology, Washington, DC (United States)

    2018-02-15

    To characterise MRI features of invasive placenta previa and to identify specific features for differentiating placenta percreta (PP) from placenta accreta (PA). Forty-five women with PP and 93 women with PA who underwent 1.5T placental MRI were included. Two radiologists independently evaluated the MRI features of invasive placenta previa, including our novel type of placental bulge (i.e. placental bulge type-II, characterized by placental bulge with distorted uterine outline). Pearson's chi-squared or Fisher's two-sided exact test was performed to compare the MRI features between PP and PA. Logistic stepwise regression analysis and the area under the receiver operating characteristic curve (AUC) were performed to select the optimal features for differentiating PP from PA. Significant differences were found in nine MRI features between women with PP and those with PA (P <0.05). Placental bulge type-II and uterine serosal hypervascularity were independently associated with PP (odds ratio = 48.618, P < 0.001; odds ratio = 4.165, P = 0.018 respectively), and the combination of the two MRI features to distinguish PP from PA yielded an AUC of 0.92 for its predictive performance. Placental bulge type-II and uterine serosal hypervascularity are useful MRI features for differentiating PP from PA. (orig.)

  15. Lactate and T2 measurements of synovial aspirates at 1.5 T: differentiation of septic from non-septic arthritis

    International Nuclear Information System (INIS)

    Wiener, Edzard; Zanetti, Marco; Hodler, Juerg; Pfirrmann, Christian W.A.

    2008-01-01

    The aim of this study was to differentiate septic from non-septic arthritis by measuring lactate concentration with 1 H magnetic resonance spectroscopy (HMRS) and by estimating total protein content with the assessment of T 2 values. In 30 patients with acute arthritis, synovial fluid was aspirated. Lactate concentrations were analyzed with single voxel HMRS at 1.5 T. T 2 relaxation times were mapped with a multi-spin echo sequence. All samples underwent microbiological testing and routine laboratory analysis to quantify lactate concentration and total protein content. Values obtained in septic and non-septic arthritis were compared with a Mann-Whitney U test. Synovial fluid from patients with septic arthritis (n=10) had higher concentrations of lactate (11.4 ± 4.0 mmol/L) and higher total protein content (51.8 ± 10.7 g/L) than fluid obtained in non-septic arthritis (n=20; 5.2±1.1 mmol/L and 40.4±6.9 g/L, respectively, p 2 relaxation times (as an indicator of total protein content) were moderately correlated to laboratory-confirmed lactate concentration (r 2 =0.71) and total protein content (r 2 =0.73). Markedly increased lactate concentrations (>6 mmol/L) in combination with low T 2 values ( 2 may be of value in the differentiation of septic from non-septic arthritis. (orig.)

  16. Fate of the herbicides 2,4,5-T, atrazine, and DNOC in a shallow, anaerobic aquifer investigated by in situ passive diffusive emitters and laboratory batch experiments

    DEFF Research Database (Denmark)

    Arildskov, N.P.; Pedersen, Philip Grinder; Albrechtsen, Hans-Jørgen

    2001-01-01

    simultaneously with tritiated water (HTO) as tracer in the depth interval 3 to 4 rubs (meters below surface) by use of passive diffusive emitters. Atrazine and 2,4,5-T were persistent during the approximately 18 days residence time in the aquifer. In contrast, DNOC was rapidly removed from the water phase...... to 4 rubs and from 8 to 9 rubs. In these incubations, formation of Fe2+ and depletion of sulfate showed iron and sulfate reduction in sediment from 3 to 3.5 rubs and sulfate reduction in 3.5 to 4 rubs sediment. In sediment from 8 to 9 rubs, the dominant redox process was methane formation. In sediment...... first-order kinetics, and when normalized to the sediment/water-ratio, the field and laboratory derived rate constants compared well. The DNOC degradation in the methanogenic incubations (8 to 9 rubs) was up to 50 times faster than in the sediments from 3 to 4 rubs, likely due to the low redox potential....

  17. Are rheumatoid arthritis patients discernible from other early arthritis patients using 1.5T extremity magnetic resonance imaging? a large cross-sectional study.

    Science.gov (United States)

    Stomp, Wouter; Krabben, Annemarie; van der Heijde, Désirée; Huizinga, Tom W J; Bloem, Johan L; van der Helm-van Mil, Annette H M; Reijnierse, Monique

    2014-08-01

    Magnetic resonance imaging (MRI) is increasingly used in rheumatoid arthritis (RA) research. A European League Against Rheumatism (EULAR) task force recently suggested that MRI can improve the certainty of RA diagnosis. Because this recommendation may reflect a tendency to use MRI in daily practice, thorough studies on the value of MRI are required. Thus far no large studies have evaluated the accuracy of MRI to differentiate early RA from other patients with early arthritis. We performed a large cross-sectional study to determine whether patients who are clinically classified with RA differ in MRI features compared to patients with other diagnoses. In our study, 179 patients presenting with early arthritis (median symptom duration 15.4 weeks) underwent 1.5T extremity MRI of unilateral wrist, metacarpophalangeal, and metatarsophalangeal joints according to our arthritis protocol, the foot without contrast. Images were scored according to OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Scoring (RAMRIS) by 2 independent readers. Tenosynovitis was also assessed. The main outcome was fulfilling the 1987 American College of Rheumatology (ACR) criteria for RA. Test characteristics and areas under the receiver-operator-characteristic curves (AUC) were evaluated. In subanalyses, the 2010 ACR/EULAR criteria were used as outcome, and analyses were stratified for anticitrullinated protein antibodies (ACPA). The ACR 1987 criteria were fulfilled in 43 patients (24.0%). Patients with RA had higher scores for synovitis, tenosynovitis, and bone marrow edema (BME) than patients without RA (p arthritis patients.

  18. Appearance of choroidal melanoma on high resolution MRI using 1.5 T and a dedicated surface coil in 200 consecutive patients

    International Nuclear Information System (INIS)

    Lemke, A.J.; Hosten, N.; Frenzel, D.; Richter, M.; Felix, R.; Bornfeld, N.; Bechrakis, N.E.

    1998-01-01

    Purpose: Choroidal melanomas usually present a characteristic appearance in MRI. Differing characteristics can cause problems in differential diagnosis between melanomas and other masses in the globe. The purpose of this study was to evaluate the appearance of choroidal melanomas with MRI in a large consecutive patient group. Methods: In a prospective study, 200 patients with choroidal melanomas were investigated with MRI using a 1.5 T scanner and a 5 cm surface coil. Both quantitative and qualitative evaluation of the resulting images was performed. Results: 78.5% of the melanomas presented with homogeneous signal intensities within the tumor due to a homogeneous pigmentation whereas 21.5% of the melanomas demonstrated a mixed pigmentation. Signal intensities of the homogeneous melanomas in the plain T 1 -WI were moderately or markedly hyperintense compared to the vitreous in 29.3% and moderately or markedly hypointense in the T 2 -WI in 37.1%. An accompanying retinal detachment was found in 65.5% and an extraocular growth in 7.0%. Conclusions: In 10% to 37% we observed the typical well known MR appearance, including homogenous high signal in the T 1 -WI and low signals in the T 2 -WI. For further differentiation, morphological criteria (e.g. shape, size, and position) were used, which are also discussed. (orig.) [de

  19. Numerical simulation of quench protection for a 1.5 T persistent mode MgB2 conduction-cooled MRI magnet

    Science.gov (United States)

    Deissler, Robert J.; Baig, Tanvir; Poole, Charles; Amin, Abdullah; Doll, David; Tomsic, Michael; Martens, Michael

    2017-02-01

    The active quench protection of a 1.5 T MgB2 conduction-cooled MRI magnet operating in persistent current mode is considered. An active quench protection system relies on the detection of the resistive voltage developed in the magnet, which is used to trigger the external energizing of quench heaters located on the surfaces of all ten coil bundles. A numerical integration of the heat equation is used to determine the development of the temperature profile and the maximum temperature in the coil at the origin, or ‘hot spot’, of the quench. Both n-value of the superconductor and magnetoresistance of the wire are included in the simulations. An MgB2 wire manufactured by Hyper Tech Research, Inc. was used as the basis to model the wire for the simulations. With the proposed active quench protection system, the maximum temperature was limited to 200 K or less, which is considered low enough to prevent damage to the magnet. By substituting Glidcop for the Monel in the wire sheath or by increasing the thermal conductivity of the insulation, the margin for safe operation was further increased, the maximum temperature decreasing by more than 40 K. The strain on the MgB2 filaments is calculated using ANSYS, verifying that the stress and strain limits in the MgB2 superconductor and epoxy insulation are not exceeded.

  20. Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Omoumi, Patrick [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland); Rubini, Alexandra; Berg, Bruno C. vande; Lecouvet, Frederic E. [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Dubuc, Jean-Emile [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Orthopedic Surgery, Brussels (Belgium)

    2015-04-01

    To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. (orig.)

  1. Invasive placenta previa: Placental bulge with distorted uterine outline and uterine serosal hypervascularity at 1.5T MRI - useful features for differentiating placenta percreta from placenta accreta.

    Science.gov (United States)

    Chen, Xin; Shan, Ruiqin; Zhao, Lianxin; Song, Qingxu; Zuo, Changting; Zhang, Xinjuan; Wang, Shanshan; Shi, Honglu; Gao, Fei; Qian, Tianyi; Wang, Guangbin; Limperopoulos, Catherine

    2018-02-01

    To characterise MRI features of invasive placenta previa and to identify specific features for differentiating placenta percreta (PP) from placenta accreta (PA). Forty-five women with PP and 93 women with PA who underwent 1.5T placental MRI were included. Two radiologists independently evaluated the MRI features of invasive placenta previa, including our novel type of placental bulge (i.e. placental bulge type-II, characterized by placental bulge with distorted uterine outline). Pearson's chi-squared or Fisher's two-sided exact test was performed to compare the MRI features between PP and PA. Logistic stepwise regression analysis and the area under the receiver operating characteristic curve (AUC) were performed to select the optimal features for differentiating PP from PA. Significant differences were found in nine MRI features between women with PP and those with PA (P Placental bulge type-II and uterine serosal hypervascularity were independently associated with PP (odds ratio = 48.618, P Placental bulge type-II and uterine serosal hypervascularity are useful MRI features for differentiating PP from PA. • Placental bulge type-II demonstrated the strongest independent association with PP. • Uterine serosal hypervascularity is a useful feature for differentiating PP from PA. • MRI features associated with abnormal vessels increase the risk of massive haemorrhage.

  2. Invasive placenta previa. Placental bulge with distorted uterine outline and uterine serosal hypervascularity at 1.5T MRI - useful features for differentiating placenta percreta from placenta accreta

    International Nuclear Information System (INIS)

    Chen, Xin; Zhang, Xinjuan; Wang, Shanshan; Shi, Honglu; Gao, Fei; Wang, Guangbin; Shan, Ruiqin; Zhao, Lianxin; Song, Qingxu; Zuo, Changting; Qian, Tianyi; Limperopoulos, Catherine

    2018-01-01

    To characterise MRI features of invasive placenta previa and to identify specific features for differentiating placenta percreta (PP) from placenta accreta (PA). Forty-five women with PP and 93 women with PA who underwent 1.5T placental MRI were included. Two radiologists independently evaluated the MRI features of invasive placenta previa, including our novel type of placental bulge (i.e. placental bulge type-II, characterized by placental bulge with distorted uterine outline). Pearson's chi-squared or Fisher's two-sided exact test was performed to compare the MRI features between PP and PA. Logistic stepwise regression analysis and the area under the receiver operating characteristic curve (AUC) were performed to select the optimal features for differentiating PP from PA. Significant differences were found in nine MRI features between women with PP and those with PA (P <0.05). Placental bulge type-II and uterine serosal hypervascularity were independently associated with PP (odds ratio = 48.618, P < 0.001; odds ratio = 4.165, P = 0.018 respectively), and the combination of the two MRI features to distinguish PP from PA yielded an AUC of 0.92 for its predictive performance. Placental bulge type-II and uterine serosal hypervascularity are useful MRI features for differentiating PP from PA. (orig.)

  3. The magnetization transfer effect in brain studies by 1.5 T magnetic resonance system. When the radiographer should apply it?

    International Nuclear Information System (INIS)

    Ribeiro, M. Margarida; Farinha, Sara; Costa, Joana; Mauricio, J. Cruz; O' Neill, J. Goyri

    2011-01-01

    Purpose: The Magnetization Transfer (MT) obtained by applying a pre-saturation pulse is, in Magnetic Resonance Imaging (MRI), a technique that allows for additional enhancement of lesions on conventional T1 images after contrast administration. This study aims to assess the effectiveness of the technique measuring how MT could improve image quality and diagnostic values through the enhancement of lesions. Methods: Thirteen T1-weighted spin-echo (SE) sequences, obtained by the 1.5 T system after contrast media injection, were analyzed with and without MT. The contrast-to-noise ratio (CNR), as well as the signal-to-noise ratio (SNR) variables were compared in all sequences, according to the reference structures: lateral ventricles, white matter, gray matter, caudate nucleus and internal capsule. The MT ratio average was calculated using the ANOVA scale in order to assess the CNR and the magnetization transfer effect (MTE) for the different lesions and for both sequences (with and without MT). For the assessment of the flow artifact, clinical experts applied a Likert scale with 5 points. Results: For CNR values, the differences between conventional and MT-pulsed images were significant (Student t testp 0,05). Conclusion: In identical conditions of acquisition, the MT does not produce significant differences in the enhancement of lesions, however, it allows a greater capacity to detect the multiple sclerosis plaques, comparing structures around basal nucleus versus gray and white matter.

  4. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    International Nuclear Information System (INIS)

    Minaif, Karine; Ajzen, Sergio; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob; Ruano, Jose Maria Cordeiro; Noguti, Alberto Sinhiti

    2008-01-01

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  5. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minaif, Karine; Ajzen, Sergio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: kminaif@uol.com.br; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis. Unit of Abdomen; Ruano, Jose Maria Cordeiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology. Sector of Videlaparoscopy; Noguti, Alberto Sinhiti [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology

    2008-11-15

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  6. Polyethylene glycol-covered ultra-small Gd2O3 nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning

    Science.gov (United States)

    Fortin, Marc-André; Petoral, Rodrigo M., Jr.; Söderlind, Fredrik; Klasson, A.; Engström, Maria; Veres, Teodor; Käll, Per-Olof; Uvdal, Kajsa

    2007-10-01

    The size distribution and magnetic properties of ultra-small gadolinium oxide crystals (US-Gd2O3) were studied, and the impact of polyethylene glycol capping on the relaxivity constants (r1, r2) and signal intensity with this contrast agent was investigated. Size distribution and magnetic properties of US-Gd2O3 nanocrystals were measured with a TEM and PPMS magnetometer. For relaxation studies, diethylene glycol (DEG)-capped US-Gd2O3 nanocrystals were reacted with PEG-silane (MW 5000). Suspensions were adequately dialyzed in water to eliminate traces of Gd3+ and surfactants. The particle hydrodynamic radius was measured with dynamic light scattering (DLS) and the proton relaxation times were measured with a 1.5 T MRI scanner. Parallel studies were performed with DEG-Gd2O3 and PEG-silane-SPGO (Gd2O3,DTPA and the r2/r1 ratio was 1.4. PEG-silane-SPGO gave low r1 relaxivities and high r2/r1 ratios, less compatible with positive contrast agent requirements. Higher r1 were obtained with PEG-silane in comparison to DEG-Gd2O3. Treatment of DEG-US-Gd2O3 with PEG-silane provides enhanced relaxivity while preventing aggregation of the oxide cores. This study confirms that PEG-covered Gd2O3 nanoparticles can be used for positively contrasted MR applications requiring stability, biocompatible coatings and nanocrystal functionalization.

  7. Imaging of Herniated Discs of the Cervical Spine: Inter-Modality Differences between 64-Slice Multidetector CT and 1.5-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Ji Sook; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Han, Jong Kyu [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Kim, Hyun Joo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2015-08-15

    To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI.

  8. Feasibility study of simultaneous physical examination and dynamic MR imaging of medial collateral ligament knee injuries in a 1.5-T large-bore magnet

    International Nuclear Information System (INIS)

    Studler, Ueli; White, Lawrence M.; Deslandes, Melanie; Sussman, Marshall S.; Geddes, Christopher; Theodoropoulos, John

    2011-01-01

    To determine the feasibility of evaluating medial knee joint laxity with dynamic magnetic resonance (MR) imaging and simultaneous physical joint examination in a large-bore 1.5-T system. The study included 10 patients (5 women, 5 men; mean age 35 years) with clinically diagnosed and categorized acute injuries of the medial collateral ligament (MCL). Intermittent valgus stress was applied separately to both the affected and the contralateral knee joint during dynamic MR imaging with a two-dimensional fast low-angle shot sequence. The width of the medial joint space and the opening angle between the femoral condyles and the tibial plateau were measured. Results obtained from dynamic MR imaging of the affected knee were compared with morphological MCL changes on static MRI, to kinematics of the contralateral side and to the clinical grading of MCL injuries. On clinical examination, all patients had grade 2 MCL injuries except one, who had a grade 1 lesion. Using morphological MRI criteria, 9 grade II and 1 grade III injuries were seen. Mean medial joint space width and opening angles of all affected knees were 2.8 mm and 2.7 respectively, compared with 1.7 mm and 2.1 on the contralateral side. The Wilcoxon signed rank test indicated that the differences in width (P = 0.005) and opening angle (P = 0.037) between the affected and contralateral knees were significant. Dynamic MR imaging and simultaneous physical joint examination is feasible. Our results suggest that this technique might enable the imaging documentation of medial ligamentous knee instability. (orig.)

  9. Clinical indications for high-field 1.5 T intraoperative magnetic resonance imaging and neuro-navigation for neurosurgical procedures. Review of initial 100 cases

    International Nuclear Information System (INIS)

    Maesawa, Satoshi; Nakahara, Norimoto; Watanabe, Tadashi; Fujii, Masazumi; Saito, Kiyoshi; Kajita, Yasukazu; Nagatani, Tetsuya; Wakabayashi, Toshihiko; Yoshida, Jun

    2009-01-01

    Initial experiences are reviewed in an integrated operation theater equipped with an intraoperative high-field (1.5 T) magnetic resonance (MR) imager and neuro-navigation (BrainSUITE), to evaluate the indications and limitations. One hundred consecutive cases were treated, consisting of 38 gliomas, 49 other tumors, 11 cerebrovascular diseases, and 2 functional diseases. The feasibility and usefulness of the integrated theater were evaluated for individual diseases, focusing on whether intraoperative images (including diffusion tensor imaging) affected the surgical strategy. The extent of resection and outcomes in each histological category of brain tumors were examined. Intraoperative high-field MR imaging frequently affected or modified the surgical strategy in the glioma group (27/38 cases, 71.1%), but less in the other tumor group (13/49 cases, 26.5%). The surgical strategy was not modified in cerebrovascular or functional diseases, but the success of procedures and the absence of complications could be confirmed. In glioma surgery, subtotal or greater resection was achieved in 22 of the 31 patients (71%) excluding biopsies, and intraoperative images revealed tumor remnants resulting in the extension of resection in 21 of the 22 patients (95.4%), the highest rate of extension among all types of pathologies. The integrated neuro-navigation improved workflow. The best indication for intraoperative high-field MR imaging and integrated neuro-navigation is brain tumors, especially gliomas, and is supplementary in assuring quality in surgery for cerebrovascular or functional diseases. Immediate quality assurance is provided in several types of neurosurgical procedures. (author)

  10. Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T

    International Nuclear Information System (INIS)

    Durighel, G.; Tokarczuk, P.F.; Karsa, A.; Gordon, F.; Cook, S.A.; O'Regan, D.P.

    2016-01-01

    Aim: To assess whether susceptibility-weighted imaging (SWI) provides better image contrast for the detection of haemorrhagic ischaemia–reperfusion injury in the heart. Materials and methods: Thirty patients (all men; mean age 53 years) underwent cardiac magnetic resonance imaging (MRI) within 7 days of primary percutaneous intervention for acute ST elevation myocardial infarction (STEMI). Multiple gradient-echo T2* sequences with magnitude and phase reconstructions were acquired. A high-pass filtered phase map was used to create a mask for the SWI reconstructions. The difference in image contrast was assessed in those patients with microvascular obstruction. A mixed effects regression model was used to test the effect of echo time and reconstruction method on phase and contrast-to-noise ratio (CNR). Medians and interquartile ranges (IQR) are reported. Results: T2* in haemorrhagic infarcts was shorter than in non-haemorrhagic infarcts (33.5 ms [24.9–43] versus 49.9 ms [44.6–67.6]; p=0.0007). The effect of echo time on phase was significant (p<0.0001), as was the effect of haemorrhage on phase (p=0.0016). SWI reconstruction had a significant effect on the CNR at all echo times (echoes 1–5, p<0.0001; echo 6, p=0.01; echo 7, p=0.02). The median echo number at which haemorrhage was first visible was less for SWI compared to source images (echo 2 versus echo 5, p=0.0002). Conclusion: Cardiac SWI improves the contrast between myocardial haemorrhage and the surrounding tissue following STEMI and has potential as a new tool for identifying patients with ischaemia–reperfusion injury. - Highlights: • Cardiac susceptibility-weighted imaging (SWI) is feasible at 1.5T. • Combining phase and modulus data allows blood products to be seen at shorter echo times. • This sequence improves visualisation of reperfusion myocardial haemorrhage.

  11. How MRI Compatible is 'MRI Compatible'? A Systematic Comparison of Artifacts Caused by Biopsy Needles at 3.0 and 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias, E-mail: tpenzkofer@ukaachen.de [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Peykan, Nilufar [Klinikum Osnabrueck, Roentgen- und Strahlenklinik (Germany); Schmidt, Katja [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Krombach, Gabriele [Justus-Liebig University Giessen, Department of Radiology (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2013-12-15

    Purpose: This study was designed to systematically investigate artifacts caused by interventional needles recommended for use in MRI, with focus on field strength, needle/mandrin type, orientation and sequence. Methods: Eight different MRI compatible needles were placed in porcine tissue and examined at 1.5 and 3.0 T with balanced-steady-state-free-precession (B-SSFP) and T1-weighted-spoiled-gradient-echo (T1-SPGR) sequences in different orientations to B{sub 0}. Artifact diameters with regards to the primary, inner, and secondary, outer artifacts were assessed and statistically evaluated. Results: The types and degree of artifacts varied considerably, especially between different mandrin types even for the same needles. Orientation of the needle in the magnetic field was another main contributor to the artifact dimensions. Less important factors were the type of pulse sequence and field strength. Artifacts ranged from 0.7 mm (steel, 0 Degree-Sign , B-SSFP, 3.0 T, inner) to 71.4 mm (nitinol, 90 Degree-Sign , B-SSFP, 1.5 T, outer). Inner artifact diameters in B-SSFP were slightly larger (8.2 {+-} 5.7 mm) than those in T1-SPGR (7.6 {+-} 5.4 mm) and comparable between 1.5 and 3.0 T (e.g., 8.0 vs. 8.4 mm, B-SSFP). Conclusions: Although all were sold as 'MR compatible,' the artifacts differed greatly between needle types, and even more so for different mandrins. The results suggest an empirical approach to the needle choice based on lesion type and approach angle.

  12. How MRI Compatible is “MRI Compatible”? A Systematic Comparison of Artifacts Caused by Biopsy Needles at 3.0 and 1.5 T

    International Nuclear Information System (INIS)

    Penzkofer, Tobias; Peykan, Nilufar; Schmidt, Katja; Krombach, Gabriele; Kuhl, Christiane K.

    2013-01-01

    Purpose: This study was designed to systematically investigate artifacts caused by interventional needles recommended for use in MRI, with focus on field strength, needle/mandrin type, orientation and sequence. Methods: Eight different MRI compatible needles were placed in porcine tissue and examined at 1.5 and 3.0 T with balanced-steady-state-free-precession (B-SSFP) and T1-weighted-spoiled-gradient-echo (T1-SPGR) sequences in different orientations to B 0 . Artifact diameters with regards to the primary, inner, and secondary, outer artifacts were assessed and statistically evaluated. Results: The types and degree of artifacts varied considerably, especially between different mandrin types even for the same needles. Orientation of the needle in the magnetic field was another main contributor to the artifact dimensions. Less important factors were the type of pulse sequence and field strength. Artifacts ranged from 0.7 mm (steel, 0°, B-SSFP, 3.0 T, inner) to 71.4 mm (nitinol, 90°, B-SSFP, 1.5 T, outer). Inner artifact diameters in B-SSFP were slightly larger (8.2 ± 5.7 mm) than those in T1-SPGR (7.6 ± 5.4 mm) and comparable between 1.5 and 3.0 T (e.g., 8.0 vs. 8.4 mm, B-SSFP). Conclusions: Although all were sold as “MR compatible,” the artifacts differed greatly between needle types, and even more so for different mandrins. The results suggest an empirical approach to the needle choice based on lesion type and approach angle

  13. Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems

    International Nuclear Information System (INIS)

    Kemper, J.; Priest, A.N.; Adam, G.; Schulze, D.; Kahl-Nieke, B.; Klocke, A.

    2007-01-01

    The objective of this paper is to evaluate magnetic field interactions at 1.5 and 3 T for 20 orthodontic devices used for fixed orthodontic therapy. Twenty springs and auxiliary parts made from varying ferromagnetic alloys were tested for magnetic field interactions in the static magnetic field at 1.5 and 3 T. Magnetic translational force F z (in millinewtons) was evaluated by determining the deflection angle β [American Society for Testing and Materials (ASTM standard test method)]. Magnetic-field-induced rotational force F rot was qualitatively determined using a five-point scale. β was found to be >45 in 13(15) devices at 1.5(3) T and translational force F z exceeded gravitational force F g on the particular object [F z 10.17-261.4 mN (10.72-566.4 mN) at 1.5(3) T]. F z was found to be up to 24.1(47.5)-fold higher than F g at 1.5(3) T. Corresponding to this, F rot on the objects was shown to be high at both field strengths (≥ +3). Three objects (at 1.5 T) and one object (at 3 T) showed deflection angles rot was found to be ≥ +3 at both field strengths. For the remaining objects, β was below 45 and torque measurements ranged from 0 to +2. Of 20 objects investigated for magnetic field interactions at 1.5(3) T, 13(15) were unsafe in magnetic resonance (MR), based on the ASTM criteria of F z . The implications of these results for orthodontic patients undergoing MRI are discussed. (orig.)

  14. Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Priest, A.N.; Adam, G. [University Medical Center of Hamburg-Eppendorf, Clinic of Diagnostic and Interventional Radiology, Hamburg (Germany); Schulze, D. [University Hospital of Freiburg, Department of Oral and Maxillofacial Surgery, Freiburg (Germany); Kahl-Nieke, B.; Klocke, A. [University Medical Center of Hamburg-Eppendorf, Department of Orthodontics, Hamburg (Germany)

    2007-02-15

    The objective of this paper is to evaluate magnetic field interactions at 1.5 and 3 T for 20 orthodontic devices used for fixed orthodontic therapy. Twenty springs and auxiliary parts made from varying ferromagnetic alloys were tested for magnetic field interactions in the static magnetic field at 1.5 and 3 T. Magnetic translational force F{sub z} (in millinewtons) was evaluated by determining the deflection angle {beta} [American Society for Testing and Materials (ASTM standard test method)]. Magnetic-field-induced rotational force F{sub rot} was qualitatively determined using a five-point scale. {beta} was found to be >45 in 13(15) devices at 1.5(3) T and translational force F{sub z} exceeded gravitational force F{sub g} on the particular object [F{sub z} 10.17-261.4 mN (10.72-566.4 mN) at 1.5(3) T]. F{sub z} was found to be up to 24.1(47.5)-fold higher than F{sub g} at 1.5(3) T. Corresponding to this, F{sub rot} on the objects was shown to be high at both field strengths ({>=} +3). Three objects (at 1.5 T) and one object (at 3 T) showed deflection angles <45 , but F{sub rot} was found to be {>=} +3 at both field strengths. For the remaining objects, {beta} was below 45 and torque measurements ranged from 0 to +2. Of 20 objects investigated for magnetic field interactions at 1.5(3) T, 13(15) were unsafe in magnetic resonance (MR), based on the ASTM criteria of F{sub z}. The implications of these results for orthodontic patients undergoing MRI are discussed. (orig.)

  15. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system; MRT-gestuetzte Markierung und Stanzbiopsie suspekter Mammalaesionen. Moeglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Horn, L.C. [Inst. fuer Pathologie, Universitaetsklinikum Leipzig (Germany); Leinung, S. [Chirurgische Klinik I, Universitaetsklinikum Leipzig (Germany); Briest, S. [Frauenklinik, Universitaetsklinikum Leipzig (Germany)

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (<10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. Conclusion. Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out in a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy. (orig.) [German] Zielsetzung. In den letzten Jahren wurde eine Vielzahl von Systemen zur praeoperativen Markierung oder Biopsie MRT-suspekter Mammalaesionen vorgestellt. Ziel unserer Untersuchungen war es, Moeglichkeiten solcher Verfahren an einem vertikal offenen 0,5-T-Magneten (SIGNA SP/i, GE Medical Systems) zu entwickeln, zu erproben und in die klinische Routine zu

  16. {sup 31}P-MR spectroscopy of all regions of the human heart at 1.5 T with acquisition-weighted chemical shift imaging; P-MR-Spektroskopie aller Wandabschnitte des menschlichen Herzens bei 1,5 T mit akquisitionsgewichteter Chemical-shift-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Koestler, H.; Beer, M.; Buchner, S.; Sandstede, J.; Pabst, T.; Kenn, W.; Hahn, D. [Wuerzburg Univ. (Germany). Abt. fuer Roentgendiagnostik; Landschuetz, W.; Kienlin, M. von [Wuerzburg Univ. (Germany). Physikalisches Inst.; Neubauer, S. [Dept. of Cardiovascular Medicine, John Radcliffe Hospital, Oxford (United Kingdom)

    2001-12-01

    Aim: Aim of this study was to show whether or not acquisition-weighted chemical shift imaging (AW-CSI) allows the determination of PCr and ATP in the lateral and posterior wall of the human heart at 1.5 T. Methods: 12 healthy volunteers were examined using a conventional chemical shift imaging (CSI) and an AW-CSI. The sequences differed only in the number of repetitions for each point in k space. A hanning function was used as filter function leading to 7 repetitions in the center of the k space and 0 in the corners. Thus, AW-CSI had the same resolution as the CSI sequence. The results for both sequences were analyzed using identically positioned voxels in the septal, anterior, lateral and posterior wall. Results: The determined averaged AW-CSI signal to noise ratios were higher for PCr by a factor of 1.3 and for ATP by 1.4 than those of CSI. The PCr/ATP ratios were higher by a factor of 1.2 - 1.3 and showed a smaller standard deviation in all locations for AW-CSI. The mean PCr/ATP ratios determined by AW-CSI of septal, lateral and posterior wall were almost identical (1.72 - 1.76), while it was higher in the anterior wall (1.9). Conclusions: The reduced contamination in AW-CSI improves the signal to noise ratio and the determination of the PCr/ATP ratio in cardiac {sup 31}P spectroscopy compared to CSI with the same resolution. The results in volunteers indicate that AW-CSI renders {sup 31}P spectroscopy of the lateral and posterior wall of the human heart feasible for patient studies at 1.5 T. (orig.) [German] Ziel: Ziel der Arbeit war es zu untersuchen, ob die akquisitionsgewichtete Chemical-shift-Bildgebung (AW-CSI) die Bestimmung von PCr und ATP in der Seiten- und Hinterwand des menschlichen Herzens an einem klinischen 1,5 T MR-Tomographen erlaubt. Methoden: 12 gesunde Probanden wurden jeweils mit einer chemical shift imaging (CSI) und einer AW-CSI-Sequenz untersucht. Die Sequenzen unterschieden sich lediglich in der Anzahl der Wiederholungen der einzelnen

  17. Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Meike [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Frauenrath, Tobias; Hezel, Fabian [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany); Krombach, Gabriele A.; Kremer, Ute; Koppers, Benedikt [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Butenweg, Christoph; Goemmel, Andreas [Chair of Structural Statics and Dynamics, RWTH Aachen, Aachen (Germany); Utting, Jane F. [MRI, NHS Grampian, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Schulz-Menger, Jeanette [Humboldt-University, Working Group Cardiovascular MR, Franz-Volhard-Klinik, Department of Cardiology, HELIOS-Klinikum Berlin-Buch and Charite Campus Buch, Berlin (Germany); Niendorf, Thoralf [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany)

    2010-06-15

    As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n = 14). Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct R-wave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects - even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived from VCG-triggered acquisitions (1.5 T: ESV{sub VCG} = (56 {+-} 17) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (97 {+-} 27) g, SV{sub VCG} = (94 {+-} 19) ml, EF{sub VCG} = (63 {+-} 5)% cf. ESV{sub ACT} = (56 {+-} 18) ml, EDV{sub ACT} = (147 {+-} 36) ml, LVM{sub ACT} = (102 {+-} 29) g, SV{sub ACT} = (91 {+-} 22) ml, EF{sub ACT} = (62 {+-} 6)%; 3.0 T: ESV{sub VCG} = (55 {+-} 21) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (101 {+-} 27) g, SV{sub VCG} = (96 {+-} 15) ml, EF{sub VCG} = (65 {+-} 7)% cf. ESV{sub ACT} = (54 {+-} 20) ml, EDV{sub ACT} = (146 {+-} 35) ml, LVM{sub ACT} = (101 {+-} 30) g, SV{sub ACT} = (92 {+-} 17) ml, EF{sub ACT} = (64 {+-} 6)%). ACT's intrinsic insensitivity to interference from electromagnetic fields renders it suitable for clinical CMR. (orig.)

  18. Delayed perfusion phenomenon in a rat stroke model at 1.5 T MR: An imaging sign parallel to spontaneous reperfusion and ischemic penumbra?

    Energy Technology Data Exchange (ETDEWEB)

    Chen Feng [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Department of Radiology, Zhong Da Hospital, Southeast University, 87 Ding Jia Qiao Road, Nanjing 210009, Jiangsu Province (China); Suzuki, Yasuhiro [Department of Molecular and Cellular Medicine, Faculty of Medicine, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Department of Pharmacology, Hamamatsu University School of Medicine, 1-20-1 Handayama, 431-3192 Hamamatsu (Japan); Nagai, Nobuo [Department of Molecular and Cellular Medicine, Faculty of Medicine, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Sun Xihe [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Department of Radiology, the Affiliated Hospital of Weifang Medical University, Weifang 261031, Shandong Province (China); Coudyzer, Walter [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Yu Jie [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Marchal, Guy [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium); Ni Yicheng [Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven (Belgium)]. E-mail: Yicheng.Ni@med.kuleuven.ac.be

    2007-01-15

    Introduction: Delayed perfusion (DP) sign at MR imaging was reported in stroke patients. We sought to experimentally elucidate its relation to spontaneous reperfusion and ischemic penumbra. Methods: Stroke was induced by photothrombotic occlusion of middle cerebral artery in eight rats and studied up to 72 h using a 1.5 T MR scanner with T2 weighted imaging (T2WI), diffusion weighted imaging (DWI), and dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI). Relative signal intensity (rSI), relative lesion volume (rLV), relative cerebral blood flow (rCBF), PWI{sub rLV}-DWI{sub rLV} mismatch (penumbra) and DP{sub rLV} were quantified and correlated with neurological deficit score (NDS), triphenyl tetrazolium chloride (TTC) staining, microangiography (MA) and histopathology. Results: The rSI and rLV characterized this stroke model on different MRI sequences and time points. DSC-PWI reproduced cortical DP in all rats, where rCBF evolved from 88.9% at 1 h through 64.9% at 6 h to 136.3% at 72 h. The PWI{sub rLV}-DWI{sub rLV} mismatch reached 10 {+-} 5.4% at 1 h, remained positive through 12 h and decreased to -3.3 {+-} 4.5% at 72 h. The incidence and rLV of the DP were well correlated with those of the penumbra (p < 0.01, r {sup 2} = 0.85 and p < 0.0001, r {sup 2} = 0.96, respectively). Shorter DP durations and more collateral arterioles occurred in rats without (n = 4) than with (n = 4) cortex involvement (p < 0.05). Rats without cortex involvement tended to earlier reperfusion and a lower NDS. Microscopy confirmed MRI, MA and TTC findings. Conclusions: In this rat stroke model, we reproduced clinically observed DP on DSC-PWI, confirmed spontaneous reperfusion, and identified the penumbra extending to 12 h post-ischemia, which appeared interrelated.

  19. Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T

    International Nuclear Information System (INIS)

    Gutberlet, Matthias; Schwinge, Kerstin; Freyhardt, Patrick; Spors, Birgit; Grothoff, Matthias; Denecke, Timm; Luedemann, Lutz; Felix, Roland; Noeske, Ralph; Niendorf, Thoralf

    2005-01-01

    The aim of this paper is to examine signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality of cardiac CINE imaging at 1.5 T and 3.0 T. Twenty volunteers underwent cardiac magnetic resonance imaging (MRI) examinations using a 1.5-T and a 3.0-T scanner. Three different sets of breath-held, electrocardiogram-gated (ECG) CINE imaging techniques were employed, including: (1) unaccelerated SSFP (steady state free precession), (2) accelerated SSFP imaging and (3) gradient-echo-based myocardial tagging. Two-dimensional CINE SSFP at 3.0 T revealed an SNR improvement of 103% and a CNR increase of 19% as compared to the results obtained at 1.5 T. The SNR reduction in accelerated 2D CINE SSFP imaging was larger at 1.5 T (37%) compared to 3.0 T (26%). The mean SNR and CNR increase at 3.0 T obtained for the tagging sequence was 88% and 187%, respectively. At 3.0 T, the duration of the saturation bands persisted throughout the entire cardiac cycle. For comparison, the saturation bands were significantly diminished at 1.5 T during end-diastole. For 2D CINE SSFP imaging, no significant difference in the left ventricular volumetry and in the overall image quality was obtained. For myocardial tagging, image quality was significantly improved at 3.0 T. The SNR reduction in accelerated SSFP imaging was overcompensated by the increase in the baseline SNR at 3.0 T and did not result in any image quality degradation. For cardiac tagging techniques, 3.0 T was highly beneficial, which holds the promise to improve its diagnostic value. (orig.)

  20. Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee. Establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T

    International Nuclear Information System (INIS)

    Moriya, Susumu; Miki, Yukio; Matsuno, Yukako; Okada, Masayo

    2012-01-01

    Background: The effect of flip angle (FA) on synovial fluid and cartilage signal and on image contrast using three-dimensional double-echo steady-state (3D-DESS) sequence have only been performed with 1.0-T but not with 1.5-T or 3.0-T scanners. Purpose: To identify the FA that gives the maximum synovial fluid and cartilage values, and to identify the FA at which maximum values of synovial fluid-cartilage contrast-to-noise ratio (CNR) in 3D-DESS sequences when 1.5-T and 3.0-T scanners are used. Material and Methods: Using 3D-DESS with water-excitation pulse, mid-sagittal plane images of the knees of 10 healthy volunteers (5 men, 5 women; age range, 21-42 years) were obtained with FA varying from 10 deg to 90 deg. Synovial fluid signals, cartilage signals, and background were measured at each FA, and the FA that gave the highest synovial fluid and cartilage values was obtained. Synovial fluid-cartilage CNR was also calculated, and the FA that gave the largest CNR was obtained. Results: At 1.5 T, the maximum synovial fluid signal was at FA 90 deg, and the maximum cartilage signal was at FA 30 deg. Synovial fluid-cartilage CNR was highest at FA 90 deg (P < 0.05). At 3.0 T, the maximum synovial fluid signal was at FA 90 deg, and the maximum cartilage signal was at FA 20 deg. Synovial fluid-cartilage CNR was highest at FA 90 deg (P < 0.05). Conclusion: In order to improve the visibility of cartilage itself, FA settings of 30 deg at 1.5 T and 20 deg at 3.0 T are apparently ideal. For observing the cartilage surface, the most effective FA setting is 90 deg for both 1.5 T and 3.0 T

  1. Discrimination of benign and malignant lymph nodes at 7.0T compared to 1.5T magnetic resonance imaging using ultrasmall particles of iron oxide: a feasibility preclinical study.

    Science.gov (United States)

    Kinner, Sonja; Maderwald, Stefan; Albert, Juliane; Parohl, Nina; Corot, Claire; Robert, Philippe; Baba, Hideo A; Barkhausen, Jörg

    2013-12-01

    To investigate the feasibility and performance of 7T magnetic resonance imaging compared to 1.5T imaging to discriminate benign (normal and inflammatory changed) from tumor-bearing lymph nodes in rabbits using ultrasmall particles of iron oxide (USPIO)-based contrast agents. Six New Zealand White rabbits were inoculated with either complete Freund's adjuvant cell suspension (n = 3) to induce reactively enlarged lymph nodes or with VX2 tumor cells to produce metastatic lymph nodes (n = 3). Image acquisition was performed before and 24 hours after bolus injection of an USPIO contrast agent at 1.5T and afterward at 7T using T1-weighted and T2*-weighted sequences. Sensitivities, specificities, and negative and positive predictive values for the detection of lymph node metastases were calculated for both field strengths with histopathology serving as reference standard. Sizes of lymph nodes with no, inflammatory, and malignant changes were compared using a Mann-Whitney U-test. All 24 lymph nodes were detected at 1.5T as well as at 7T. At 1.5T, sensitivity amounted to 0.67, while specificity reached a value of 1. At the higher field strength (7T), imaging was able to reach sensitivity and specificity values of 1. No statistical differences were detected concerning lymph node sizes. Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of normal and reactively enlarged lymph nodes compared to metastatic nodes. First experiments at 7T show promising results compared to 1.5T, which have to be evaluated in further trials. Copyright © 2013. Published by Elsevier Inc.

  2. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    Energy Technology Data Exchange (ETDEWEB)

    Crespo-Rodríguez, Ana M., E-mail: anacresporodriguez@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); De Lucas-Villarrubia, Jose C., E-mail: jclucasv@hotmail.com [Department of Orthopaedics and Traumatology at the Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Pastrana-Ledesma, Miguel, E-mail: m.pastrana@telefonica.net [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Hualde-Juvera, Ana, E-mail: ana.hualdej@salud.madrid.org [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Méndez-Alonso, Santiago, E-mail: smendez.sma@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Padron, Mario, E-mail: mario.padron@clinicacemtro.com [Department of Radiology, Clínica Cemtro, Avda Ventisquero de la Condesa 42 Madrid 28035, Madrid (Spain)

    2017-03-15

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  3. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    International Nuclear Information System (INIS)

    Crespo-Rodríguez, Ana M.; De Lucas-Villarrubia, Jose C.; Pastrana-Ledesma, Miguel; Hualde-Juvera, Ana; Méndez-Alonso, Santiago; Padron, Mario

    2017-01-01

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  4. Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Siemund, Roger; Cronqvist, Mats; Undren, Per; Holtaas, Stig; Nilsson, Ola G.; Larsson, Elna-Marie

    2008-01-01

    The purpose of this prospective study was to compare 3T and 1.5T magnetic resonance angiography (MRA) with digital subtraction angiography (DSA) for the follow-up of endovascular treated intracranial aneurysms to assess the grade of occlusion. Thirty-seven patients with 41 aneurysms who had undergone endovascular treatment with detachable coils were included. MRA was performed on the same day using an eight-channel sensitivity encoding head-coil with 3D axial inflow technique. At 3T, a contrast-enhanced transverse 3D fast gradient echo acquisition was also performed. Most patients underwent DSA the following day. MRA scans and DSA were classified first independently by two neuroradiologists and an interventional neuroradiologist. Secondly, a consensus was done. Source images, maximum intensity projection, multiplanar reconstruction and volume rendering reconstructions were used for MRA evaluations. A modification of the Raymond classification, previously used for DSA evaluation of recanalization, was used. Statistical comparison of the consensus showed that 3T MRA with 3D axial inflow technique had better agreement with DSA (κ = 0.43) than 1.5T MRA(κ = 0.21) and contrast-enhanced MRA (CE-MRA) at 3T (κ = 0.17). The susceptibility artefacts from the coil mesh were significally smaller at 3T (p = 0.002-0.007) than at 1.5T. 3T MRA, using a sensitivity encoding head-coil, showed better agreement with DSA than 1.5T and CE-MRA at 3T for evaluation of aneurysms treated with endovascular coiling. (orig.)

  5. Evaluation of Porcine Pancreatic Islets Transplanted in the Kidney Capsules of Diabetic Mice Using a Clinically Approved Superparamagnetic Iron Oxide (SPIO) and a 1.5T MR Scanner

    International Nuclear Information System (INIS)

    Kim, Hoe Suk; Kim, Hyoung Su; Park, Kyong Soo; Moon, Woo Kyung

    2010-01-01

    To evaluate transplanted porcine pancreatic islets in the kidney capsules of diabetic mice using a clinically approved superparamagnetic iron oxide (SPIO) and a 1.5T MR scanner. Various numbers of porcine pancreatic islets labeled with Resovist, a carboxydextran-coated SPIO, were transplanted into the kidney capsules of normal mice and imaged with a 3D FIESTA sequence using a 1.5T clinical MR scanner. Labeled (n = 3) and unlabeled (n = 2) islets were transplanted into the kidney capsules of streptozotocin-induced diabetic mice. Blood glucose levels and MR signal intensities were monitored for 30 days post-transplantation. There were no significant differences in viability or insulin secretion between labeled and unlabeled islets. A strong correlation (γ 2 > 0.94) was evident between the number of transplanted islets and T 2 relaxation times quantified by MRI. Transplantation with labeled or unlabeled islets helped restore normal sustained glucose levels in diabetic mice, and nephrectomies induced the recurrence of diabetes. The MR signal intensity of labeled pancreatic islets decreased by 80% over 30 days. The transplantation of SPIO-labeled porcine islets into the kidney capsule of diabetic mice allows to restore normal glucose levels, and these islets can be visualized and quantified using a 1.5T clinical MR scanner

  6. Pseudo-Bartter syndrome as the sole manifestation of cystic fibrosis in a child with 711+G>T/IVS8-5T mutation: a new face of an old disease.

    Science.gov (United States)

    Tinsa, Faten; Hadj Fredj, Sondes; Bel Hadj, Imen; Khalsi, Fatma; Abdelhak, Sonia; Boussetta, Khadija; Messaoud, Taieb

    2017-08-01

    Pseudo-Bartter syndrome (PBS) describes an uncommon complication of cystic fibrosis leading to hypochloraemic, hypokalaemic metabolic alkalosis. PBS as the sole manifestation of cystic fibrosis in children is extremely rare and has never been described in patients carrying 5T variant. We report a clinical, biochemical and genetic study of a four year-old boy presenting a pseudo-Bartter syndrome as the sole manifestation of cystic fibrosis. All 27 exons and the flanking intron regions of the CFTR gene were analysed by PCR and direct sequencing. Direct sequencing was also used to analyse TG m T n and M470V polymorphisms in the patient and his parents. Two sweat tests were abnormal with elevated chloride levels at 78 and 88 mmol/L. DNA sequencing revealed a heterozygous mutation 711+1 G>T and an IVS8-T5 allele. The mutation 711+1 G>T is in trans with the IVS8-T5-TG11 allele and the child carried M470/V470 genotype. To the best of our knowledge, the genotype 711+1 G>T /IVS8-5T found in our patient is described for the first time. The role of TG11-5T-V470 allele in cases of cystic fibrosis with PB syndrome remains to be determined.

  7. Bilateral ce-MR angiography of the hands at 3.0 T and 1.5 T: intraindividual comparison of quantitative and qualitative image parameters in healthy volunteers

    International Nuclear Information System (INIS)

    Winterer, Jan T.; Markl, Michael; Frydrychowicz, Alexander; Bley, Thorsten A.; Langer, Mathias; Moske-Eick, Olaf

    2008-01-01

    The purpose of this study was to determine the benefit of bilateral contrast-enhanced MR angiography (ce-MRA) of the hands at 3.0 Tesla (T) compared with an established 1.5-T technique in healthy volunteers. Intraindividual bilateral ce-MRA of the hands was performed at 1.5 T and 3.0 T in 14 healthy volunteers using a timed ultra-fast GRE sequence featuring parallel acquisition. The evaluation comprised measurement of the vessel signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), rating of the image quality and the assessment of artefacts and venous contamination. At 3.0 T, SNR improved up to 95% and CNR up to 129%. The image quality of the larger inflow arteries, the palm arches and common digital arteries was good or sufficient at either magnetic field strengths. However, 3.0-T MRA was clearly superior in the depiction of the digital arteries. Ce-MRA of the hand clearly profits from the use of 3.0 T. Compared with 1.5 T, a substantial increase of CNR is found resulting in a significantly better delineation of the small digital arteries. Saturation affects more the SNR of the perivascular tissue than the contrast-enhanced blood, and thus leads to a marked increase of CNR at 3.0. (orig.)

  8. Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Miyake, Mototaka; Sakurada, Aine; Arai, Yasuaki; Tsurusaki, Masakatsu; Sugimura, Kazuro

    2010-01-01

    To prospectively compare the diagnostic performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging at 3.0 T and 1.5 T for detection of hepatic metastases. A total of 28 patients (18 men, 10 women; mean age, 61 years) with 80 hepatic metastases were prospectively examined by SPIO-enhanced MR imaging at 3.0 T and 1.5 T. T1-weighted gradient-recalled-echo (GRE) images, T2*-weighted GRE images and T2-weighted fast spin-echo (SE) images were acquired. The tumour-to-liver contrast-to-noise ratio (CNR) of the lesions was calculated. Three observers independently reviewed each image. Image artefacts and overall image quality were analysed, sensitivity and positive predictive value for the detection of hepatic metastases were calculated, and diagnostic accuracy using the receiver-operating characteristics (ROC) method was evaluated. The tumour-to-liver CNRs were significantly higher at 3.0 T. Chemical shift and motion artefact were more severe, and overall image quality was worse on T2-weighted fast SE images at 3.0 T. Overall image quality of the two systems was similar on T1-weighted GRE images and T2*-weighted GRE images. Sensitivity and area under the ROC curve for the 3.0-T image sets were significantly higher. SPIO-enhanced MR imaging at 3.0 T provided better diagnostic performance for detection of hepatic metastases than 1.5 T. (orig.)

  9. Validation of highly accelerated real-time cardiac cine MRI with radial k-space sampling and compressed sensing in patients at 1.5T and 3T.

    Science.gov (United States)

    Haji-Valizadeh, Hassan; Rahsepar, Amir A; Collins, Jeremy D; Bassett, Elwin; Isakova, Tamara; Block, Tobias; Adluru, Ganesh; DiBella, Edward V R; Lee, Daniel C; Carr, James C; Kim, Daniel

    2018-05-01

    To validate an optimal 12-fold accelerated real-time cine MRI pulse sequence with radial k-space sampling and compressed sensing (CS) in patients at 1.5T and 3T. We used two strategies to reduce image artifacts arising from gradient delays and eddy currents in radial k-space sampling with balanced steady-state free precession readout. We validated this pulse sequence against a standard breath-hold cine sequence in two patient cohorts: a myocardial infarction (n = 16) group at 1.5T and chronic kidney disease group (n = 18) at 3T. Two readers independently performed visual analysis of 68 cine sets in four categories (myocardial definition, temporal fidelity, artifact, noise) on a 5-point Likert scale (1 = nondiagnostic, 2 = poor, 3 = adequate or moderate, 4 = good, 5 = excellent). Another reader calculated left ventricular (LV) functional parameters, including ejection fraction. Compared with standard cine, real-time cine produced nonsignificantly different visually assessed scores, except for the following categories: 1) temporal fidelity scores were significantly lower (P = 0.013) for real-time cine at both field strengths, 2) artifacts scores were significantly higher (P = 0.013) for real-time cine at both field strengths, and 3) noise scores were significantly (P = 0.013) higher for real-time cine at 1.5T. Standard and real-time cine pulse sequences produced LV functional parameters that were in good agreement (e.g., absolute mean difference in ejection fraction cine MRI pulse sequence using radial k-space sampling and CS produces good to excellent visual scores and relatively accurate LV functional parameters in patients at 1.5T and 3T. Magn Reson Med 79:2745-2751, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Comparison of different cardiac MRI sequences at 1.5T/3.0T with respect to signal-to-noise and contrast-to-noise ratios - initial experience

    International Nuclear Information System (INIS)

    Gutberlet, M.; Spors, B.; Grothoff, M.; Freyhardt, P.; Schwinge, K.; Plotkin, M.; Amthauer, H.; Felix, R.

    2004-01-01

    Purpose: To compare image quality, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of different MRI sequences for cardiac imaging at 1.5 T and 3.0 T in volunteers. Material and Methods: 10 volunteers (5 male, 5 female) with a mean age of 33 years (±8) without any history of cardiac diseases were examined on a GE Signa 3.0 T and a GE Signa 1.5 T TwinSpeed Excite (GE Medical Systems, Milwaukee, WI, USA) scanner using a 4-element phased array surface coil (same design) on the same day. For tissue characterization ECG gated Fast Spinecho (FSE) T 1 - (Double IR), T 1 -STIR (Triple IR) and T 2 -weighted sequences in transverse orientation were used. For functional analysis a steady state free precession (SSFP-FIESTA) sequence was performed in the 4-chamber, 2-chamber long axis and short axis view. The flip angle used for the SSFP sequence at 3.0 T was reduced from 45 to 30 to keep short TR times while staying within the pre-defined SAR limitations. All other sequence parameters were kept constant. Results: All acquisitions could successfully be completed for the 10 volunteers. The mean SNR 3.0 T compared to 1.5 T was remarkably increased (p 2 - (160% SNR increase), the STIR-T 1 - (123%) and the T 1 - (91%) weighted FSE. Similar results were found comparing CNR at 3.0 T and 1.5 T. The mean SNR achieved using the SSFP sequences was more than doubled by 3.0 T (150%), but did not have any significant effect on the CNR. The image quality at 3.0 T did not appear to be improved, and was considered to be significantly worse when using SSFP sequences. Artefacts like shading in the area of the right ventricle (RV) were found to be more present at 3.0 T using FSE sequences. After a localized shim had been performed in 5/10 volunteers at the infero-lateral wall of the left ventricle (LV) with the SSFP sequences at 3.0 T no significant increase in artefacts could be detected. (orig.) [de

  11. Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.

    Science.gov (United States)

    Bainbridge, Hannah E; Menten, Martin J; Fast, Martin F; Nill, Simeon; Oelfke, Uwe; McDonald, Fiona

    2017-11-01

    This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. Ten patients with LA NSCLC were retrospectively re-planned six times: three treatment plans were created according to a protocol for conventionally fractionated radiotherapy and three treatment plans following guidelines for isotoxic target dose escalation. In each case, two plans were designed for the MR-Linac, either with standard (∼7mm) or reduced (∼3mm) planning target volume (PTV) margins, while one conventional linac plan was created with standard margins. Treatment plan quality was evaluated using dose-volume metrics or by quantifying dose escalation potential. All generated treatment plans fulfilled their respective planning constraints. For conventionally fractionated treatments, MR-Linac plans with standard margins had slightly increased skin dose when compared to conventional linac plans. Using reduced margins alleviated this issue and decreased exposure of several other organs-at-risk (OAR). Reduced margins also enabled increased isotoxic target dose escalation. It is feasible to generate treatment plans for LA NSCLC patients on a 1.5T MR-Linac. Margin reduction, facilitated by an envisioned MRI-guided workflow, enables increased OAR sparing and isotoxic target dose escalation for the respective treatment approaches. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Was Aristotle an Exponent of Antiscientific Mumbo-Jumbo?

    Science.gov (United States)

    Koznjak, Boris

    2012-01-01

    During the past few decades, a wide consensus has been reached in the community of science educators that it is almost unimaginable to conduct a quality science education without including the history and philosophy of science in some form in the science curriculum, and this is especially the case for physics education (Matthews 1994). However, in…

  13. Isolation and characterization of microsatellites for jumbo squid ...

    Indian Academy of Sciences (India)

    2Department of Ecology and Evolutionary Biology, University of California, 100 Shaffer Road, Santa Cruz, CA 95060, USA. 3National Marine Fisheries Service, .... British Columbia. PICES Press 13, 30–31. Dakin E. E. and Avise J. C. 2004 ...

  14. A Monte-Carlo study to assess the effect of 1.5 T magnetic fields on the overall robustness of pencil-beam scanning proton radiotherapy plans for prostate cancer

    Science.gov (United States)

    Kurz, Christopher; Landry, Guillaume; Resch, Andreas F.; Dedes, George; Kamp, Florian; Ganswindt, Ute; Belka, Claus; Raaymakers, Bas W.; Parodi, Katia

    2017-11-01

    Combining magnetic-resonance imaging (MRI) and proton therapy (PT) using pencil-beam scanning (PBS) may improve image-guided radiotherapy. We aimed at assessing the impact of a magnetic field on PBS-PT plan quality and robustness. Specifically, the robustness against anatomical changes and positioning errors in an MRI-guided scenario with a 30 cm radius 1.5 T magnetic field was studied for prostate PT. Five prostate cancer patients with three consecutive CT images (CT1-3) were considered. Single-field uniform dose PBS-PT plans were generated on the segmented CT1 with Monte-Carlo-based treatment planning software for inverse optimization. Plans were optimized at 90° gantry angle without B-field (no B), with  ±1.5 T B-field (B and minus B), as well as at 81° gantry angle and  +1.5 T (B G81). Plans were re-calculated on aligned CT2 and CT3 to study the impact of anatomical changes. Dose distributions were compared in terms of changes in DVH parameters, proton range and gamma-index pass-rates. To assess the impact of positioning errors, DVH parameters were compared for  ±5 mm CT1 patient shifts in anterior-posterior (AP) and left-right (LR) direction. Proton beam deflection considerably reduced robustness against inter-fractional changes for the B scenario. Range agreement, gamma-index pass-rates and PTV V95% were significantly lower compared to no B. Improved robustness was obtained for minus B and B G81, the latter showing only minor differences to no B. The magnetic field introduced slight dosimetric changes under LR shifts. The impact of AP shifts was considerably larger, and equivalent for scenarios with and without B-field. Results suggest that robustness equivalent to PT without magnetic field can be achieved by adaptation of the treatment parameters, such as B-field orientation (minus B) with respect to the patient and/or gantry angle (B G81). MRI-guided PT for prostate cancer might thus be implemented without compromising robustness

  15. Whole-body MRI at 1.5 T and 3 T compared with FDG-PET-CT for the detection of tumour recurrence in patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, G.P.; Baur-Melnyk, A.; Becker, C.R.; Reiser, M.F.; Hermann, K.A. [Ludwig Maximilian University Munich, Department of Clinical Radiology, University Hospitals Grosshadern, Munich (Germany); Haug, A.; Tiling, R. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Nuclear Medicine, Munich (Germany); Utzschneider, S. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Orthopedics, Munich (Germany)

    2009-06-15

    The purpose of this study was to assess the diagnostic accuracy of whole-body MRI (WB-MRI) at 1.5 T or 3 T compared with FDG-PET-CT in the follow-up of patients suffering from colorectal cancer. In a retrospective study, 24 patients with a history of colorectal cancer and suspected tumour recurrence underwent FDG-PET-CT and WB-MRI with the use of parallel imaging (PAT) for follow-up. High resolution coronal T1w-TSE and STIR sequences at four body levels, HASTE imaging of the lungs, contrast-enhanced T1w- and T2w-TSE sequences of the liver, brain, abdomen and pelvis were performed, using WB-MRI at either 1.5 T (n = 14) or 3 T (n = 10). Presence of local recurrent tumour, lymph node involvement and distant metastatic disease was confirmed using radiological follow-up within at least 5 months as a standard of reference. Seventy seven malignant foci in 17 of 24 patients (71%) were detected with both WB-MRI and PET-CT. Both investigations concordantly revealed two local recurrent tumours. PET-CT detected significantly more lymph node metastases (sensitivity 93%, n = 27/29) than WB-MRI (sensitivity 63%, n = 18/29). PET-CT and WB-MRI achieved a similar sensitivity for the detection of organ metastases with 80% and 78%, respectively (37/46 and 36/46). WB-MRI detected brain metastases in one patient. One false-positive local tumour recurrence was indicated by PET-CT. Overall diagnostic accuracy for PET-CT was 91% (sensitivity 86%, specificity 96%) and 83% for WB-MRI (sensitivity 72%, specificity 93%), respectively. Examination time for WB-MRI at 1.5 T and 3 T was 52 min and 43 min, respectively; examination time for PET-CT was 103 min. Initial results suggest that differences in accuracy for local and distant metastases detection using FDG-PET-CT and WB-MRI for integrated screening of tumour recurrence in colorectal cancer depend on the location of the malignant focus. Our results show that nodal disease is better detected using PET-CT, whereas organ disease is depicted

  16. An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

    Science.gov (United States)

    Lupo, Pierpaolo; Cappato, Riccardo; Di Leo, Giovanni; Secchi, Francesco; Papini, Giacomo D E; Foresti, Sara; Ali, Hussam; De Ambroggi, Guido M G; Sorgente, Antonio; Epicoco, Gianluca; Cannaò, Paola M; Sardanelli, Francesco

    2018-06-01

    To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.

  17. Intraoperative appearance of the resection area in brain-tumor operations in an open 0,5 MRT; Intraoperatives Erscheinungsbild des Resektionsbereichs bei Hirntumoroperationen in einem offenen 0,5-T-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, J. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany). Arbeitsbereich Neuroradiologie; Schneider, J.P.; Schulz, T. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany); Seifert, V.; Trantakis, C. [Universitaetsklinik fuer Neurochirurgie, Leipzig (Germany); Kellermann, S. [Leipzig Univ. (Germany). Abt. fuer Neuropathologie

    1998-11-01

    During MRI-controlled resection of brain tumors using an open MRI system, operation-induced alterations may occur, especially enhancement of the resection cavity wall. This may simulate tumor areas, resulting in false assessment of the resection or resection of non-tumorous areas. Based on 42 MRI- and biopsy-controlled brain tumor resections in an 0.5 T open MRI (Signa SP, GE), the appearance and origin of operation-induced reactions are analyzed. In our opinion, there is a superposition of preformed peritumoral reactions by operation-induced microcontusions. The beginning of the cavity wall enhancement needs at least 10-15 min. MRI-controlled analysis of the intraoperative steps by the neurosurgeon and neuroradiologist allows discrimination of operation-induced reactions from tumor areas and leads to safe operation. (orig.) [Deutsch] Bei der intraoperativen Kontrolle von Hirntumorresektionen in offenen MRT-Geraeten kann es zu operativ induzierten Veraenderungen, insbesondere Rand-enhancement-Zonen, kommen. Diese koennen Tumorreste vortaeuschen, so dass die Radikalitaet des Eingriffs unterschaetzt wird oder nicht tumortragende Hirnareale entfernt werden. Ergebnisse und Diskussion: Anhand von 42 in einem offenen 0,5-T-MRT (Signa SP, GE) vorgenommenen, biopsiekontrollierten Hirntumoroperationen werden Erscheinungsbild und Entstehungsweise der Randveraenderungen analysiert. Bei den haeufig vorzufindenden Rand-enhancement-Zonen handelt es sich um eine Ueberlagerung von praeformierten Tumorrandreaktionen mit Mikrokontusionen. Die Ausbildung dieser Veraenderungen braucht eine Mindestzeit von 10-15 min. Die staendige Analyse der die Tumorresektion begleitenden MRT-Kontrollen durch den Operateur und einen mit der Problematik vertrauten Radiologen gestattet in der Regel die Differenzierung der operativ induzierten Veraenderungen und erhoeht damit die Sicherheit des Eingriffs. (orig.)

  18. Oral administration of choline does not affect metabolic characteristics of gliomas and normal-appearing white matter, as detected with single-voxel 1H-MRS at 1.5 T

    International Nuclear Information System (INIS)

    Chernov, Mikhail F.; Iseki, Hiroshi; Takakura, Kintomo; Muragaki, Yoshihiro; Maruyama, Takashi; Ono, Yuko; Usukura, Masao; Yoshida, Shigetoshi; Nakamura, Ryoichi; Kubo, Osami; Hori, Tomokatsu

    2009-01-01

    The present study was done for evaluation of the possible influence of the oral administration of choline on metabolic characteristics of gliomas detected with proton magnetic resonance spectroscopy ( 1 H-MRS). Thirty patients (22 men and eight women; mean age 38±15 years) with suspicious intracranial gliomas underwent single-voxel long-echo (TR 2,000 ms, TE 136 ms, 128-256 acquisitions) 1 H-MRS of the tumor, peritumoral brain tissue, and distant normal-appearing white matter before and several hours (median, 3 h; range, 1.2-3.7 h) after ingestion of choline with prescribed dose of 50 mg/kg (median actual dose, 52 mg/kg; range, 48-78 mg/kg). Investigations were done using 1.5 T clinical magnetic resonance imager. The volume of the rectangular 1 H-MRS voxel was either 3.4 or 8 cm 3 . At the time of both spectroscopic examinations, similar voxels' positioning and size and technical parameters of 1 H-MRS were used. Surgery was done in 27 patients within 1 to 68 days thereafter. In all cases, more than 80% resection of the neoplasm was attained. There were 12 low-grade gliomas and 15 high-grade gliomas. MIB-1 index varied from 0% to 51.7% (median, 13.8%). Statistical analysis did not disclose significant differences of any investigated metabolic parameter of the tumor, peritumoral brain tissue and distant normal-appearing white matter between two spectroscopic examinations. Single-voxel 1 H-MRS at 1.5 T could not detect significant changes of the metabolic characteristics of gliomas, peritumoral brain tissue, and distant normal-appearing white matter after oral administration of choline. (orig.)

  19. Comment on 'degradation of polychlorinated dibenzo-p-dioxin and dibenzofuran contaminants in 2,4,5-T by photoassisted iron-catalyzed hydrogen peroxide by J.J. Pignatello and L.Q. Huang, Wat. Res. 27, 1731-1736 (1993)'

    Digital Repository Service at National Institute of Oceanography (India)

    Sarkar, A.

    and PCDFs is not well illustrated. The entraction of triplicate samples of aqueous 2,4,5-T gave wide range of standard deviation which is statistically unaccetpable. No proper justification is provided to elucidate on unusual increase in concentration...

  20. TH-AB-BRA-03: Backscatter Dose Factors Re-Evaluated for Inhomogeneities in the Presence of a 1.5 T Magnetic Field Using the GPUMCD Monte Carlo Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S [Sunnybrook Odette Cancer Center, Toronto (Canada); Sarfehnia, A; Sahgal, A; Keller, B [Sunnybrook Odette Cancer Center, Toronto (Canada); University of Toronto, Department of Radiation Oncology, Toronto, CA (Canada)

    2016-06-15

    Purpose: To quantify the backscatter dose factors near the interfaces for clinically relevant high atomic number materials using GPUMCD for the Elekta MRI Linac. Methods: Backscatter dose factors (BSDF) were calculated as the ratio of the dose with and without the presence of the heterogeneity. The BSDF’s were calculated either in the absence or presence of an orthogonal 1.5 T magnetic field. Doses were scored in small voxels of side 1 mm in a water phantom with dimensions of 20×20×20 cm using GPUMCD (Elekta). The minimum uncertainty in dose calculations was kept to 0.5%. A slab of thickness 2 cm, representing the inhomogeneity, was placed inside the phantom with variable position from the surface of the phantom. The slab was filled with either bone, aluminum, titanium, stainless steel, or dental amalgam. The phantom was irradiated using particles sampled from a histogram which represented the true MRI Linac spectrum. Results: With the application of the 1.5 T magnetic field (B-On), all of the BSDF’s were reduced by at least 8% compared to the no magnetic field (B-Off) cases. For the B-Off case, the BSDF decreases exponentially with the upstream distance away from the interface. With B-On, the BSDF decreases exponentially for titanium, SS, and amalgam. However, it remains constant for Aluminum. In the case of bone, the BSDF increases up to a distance of 4 mm away from the interface in the presence of the magnetic field. Conclusion: The BSDF does not depend upon the thickness of the homogeneous material above the inhomogeneity for either the B-Off or B-On cases. For all the materials investigated, the BSDF is lower at the interface for the B-On case. The exponential fall-off of the BSDF away from the interface is not valid for all the materials when the magnetic field is turned ON. Funding support for this research was provided by Elekta.

  1. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

    Energy Technology Data Exchange (ETDEWEB)

    Prez, L de; Pooter, J de; Jansen, B [VSL, Delft (Netherlands); Wolthaus, J; Asselen, B van; Woodings, S; Soest, T; Kok, J; Raaymakers, B [University Medical Center Utrecht, Utrecht (Netherlands)

    2016-06-15

    Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with a new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence of B

  2. SU-F-T-451: Doses to Organs-At-Risk in the Presence and Absence of a 1.5 T Magnetic Field for NSCLC Patients Undergoing SABR

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ward, S; Kim, A; McCann, C; Ruschin, M; Cheung, P; Sahgal, A; Keller, B [Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: To determine whether the electron return effect (ERE) has deleterious effects on lung SABR plans optimized in the presence of an orthogonal 1.5 T magnetic field. Methods: Data from five NSCLC-SABR patients were used. The Dose was modeled with a 2.5 mm dose grid in the presence and absence of a magnetic field using the Monaco (Elekta) TPS with the Monte Carlo GPUMCD (v5.1) algorithm. For each patient, two plans were generated, one using our conventional Elekta Agility linac beam model and another using the Elekta MRI Linac (MRL) model. Both plans were generated on the average CT using similar dose constraints and a 5 mm PTV. The optimization was performed using our clinic’s planning criteria, with normalization of the targets such that their V99% was equal to 99%. The OAR DVHs were compared for each patient. Results: The DVH plots revealed that there were limited differences when optimizing plans in the presence or absence of the magnetic field. The mean of the absolute differences, between the two planning types, in the equivalent uniform doses (EUDs) for the OARs were: 0.3 Gy (range of 0.0 - 1.0 Gy) for the esophagus, 0.6 Gy (range of 0.1 – 1.9 Gy) for the heart, 0.5 Gy (range of 0.2 – 0.8 Gy) for the lungs, and 0.6 Gy (range of 0.2 – 1.5 Gy) for the spinal canal. Regarding the maximum doses to the serial organs, the mean of the differences were 3.0 Gy (esophagus) and 0.9 Gy (spinal canal). No trends in the differences were observed. Conclusion: This study has demonstrated that there were no major differences between plans optimized using a conventional linac and those optimized using an MRI linac with an orthogonal 1.5 T magnetic field. This is attributed to the consideration of the ERE in the optimization. This project was made possible with the financial support of Elekta.

  3. Measurement of vertebral bone marrow lipid profile at 1.5-T proton magnetic resonance spectroscopy and bone mineral density at dual-energy X-ray absorptiometry: correlation in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni; Fina, Laura [IRCCS Policlinico San Donato, Unita di Radiologia, San Donato Milanese (Italy); Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milan (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Unita di Radiologia, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-15

    Bone marrow is mainly composed of red (hematopoietic) and yellow (fatty) components. Soon after the birth there is a physiological conversion of the bone marrow from red to yellow, so that the percentage of hematopoietic cells and adipocytes changes with aging. Although bone marrow adipogenesis is a physiologic process involving all mammals, recent studies showed an accelerated marrow adipogenesis associated with several chronic conditions, including osteoporosis [4] and diabetes mellitus. Moreover, this increased marrow fat is accompanied by a decrease in bone density. Marrow fat is therefore increasingly believed to influence the bone microenvironment. Diagnostic tools for quantitative measurement of bone marrow fat and bone mineral density (BMD) include proton magnetic resonance spectroscopy (MRS) and dual-energy Xray absorptiometry (DXA), respectively. Using MRS, an inverse relationship between vertebral bone marrow fat content and lumbar BMD has been demonstrated in patients affected with osteoporosis or with diabetes mellitus. In most studies, a quite standard MRS sequence has been used, with short echo times (TE) for the measurement of the bulk methylene. In this study we sought to optimize the MRS sequence in order to try to measure other fat components of the vertebral bone marrow at 1.5 T. For this purpose, we used an animal model that allowed long acquisition times and repeated measures. Moreover, we aimed at estimating in this model the relationship between vertebral bone marrow fat content at proton MRS and BMD at DXA.

  4. Technical aspects: development, manufacture and installation of a cryo-cooled HTS coil system for high-resolution in-vivo imaging of the mouse at 1.5 T.

    Science.gov (United States)

    Ginefri, Jean-Christophe; Poirier-Quinot, Marie; Girard, Olivier; Darrasse, Luc

    2007-09-01

    Signal-to-noise ratio improvement is of major importance to achieve microscopic spatial resolution in magnetic resonance experiments. Magnetic resonance imaging of small animals is particularly concerned since it typically requires voxels of less than (100 microm)(3) to observe the small anatomical structures having size reduction by a factor of more than 10 as compared to human being. The signal-to-noise ratio can be increased by working at high static magnetic field strengths, but the biomedical interest of such high-field systems may be limited due to field-dependent contrast mechanisms and severe technological difficulties. An alternative approach that allows working in clinical imaging system is to improve the sensitivity of the radio-frequency receiver coil. This can be done using small cryogenically operated coils made either of copper or high-temperature superconducting material. We report the technological development of cryo-cooled superconducting coils for high-resolution imaging in a whole-body magnetic resonance scanner operating at 1.5 T. The technological background supporting this development is first addressed, including HTS coil design, simulation tools, cryogenic mean description and electrical characterization procedure. To illustrate the performances of superconducting coils for magnetic resonance imaging at intermediate field strength, in-vivo mouse images of various anatomic sites acquired with a 12 mm diameter cryo-cooled superconducting coil are presented.

  5. Measurement of vertebral bone marrow lipid profile at 1.5-T proton magnetic resonance spectroscopy and bone mineral density at dual-energy X-ray absorptiometry: correlation in a swine model

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Fina, Laura; Bandirali, Michele; Messina, Carmelo; Sardanelli, Francesco

    2014-01-01

    Bone marrow is mainly composed of red (hematopoietic) and yellow (fatty) components. Soon after the birth there is a physiological conversion of the bone marrow from red to yellow, so that the percentage of hematopoietic cells and adipocytes changes with aging. Although bone marrow adipogenesis is a physiologic process involving all mammals, recent studies showed an accelerated marrow adipogenesis associated with several chronic conditions, including osteoporosis [4] and diabetes mellitus. Moreover, this increased marrow fat is accompanied by a decrease in bone density. Marrow fat is therefore increasingly believed to influence the bone microenvironment. Diagnostic tools for quantitative measurement of bone marrow fat and bone mineral density (BMD) include proton magnetic resonance spectroscopy (MRS) and dual-energy Xray absorptiometry (DXA), respectively. Using MRS, an inverse relationship between vertebral bone marrow fat content and lumbar BMD has been demonstrated in patients affected with osteoporosis or with diabetes mellitus. In most studies, a quite standard MRS sequence has been used, with short echo times (TE) for the measurement of the bulk methylene. In this study we sought to optimize the MRS sequence in order to try to measure other fat components of the vertebral bone marrow at 1.5 T. For this purpose, we used an animal model that allowed long acquisition times and repeated measures. Moreover, we aimed at estimating in this model the relationship between vertebral bone marrow fat content at proton MRS and BMD at DXA.

  6. [The initial (I and II) and advanced (III and IV) stages of juvenile patellar chondromalacia. Its diagnosis by magnetic resonance using a 1.5-T magnet with FLASH sequences].

    Science.gov (United States)

    Macarini, L; Rizzo, A; Martino, F; Zaccheo, N; Angelelli, G; Rotondo, A

    1998-06-01

    Juvenile patellar chondromalacia is a common orthopedic disorder which can mimic other conditions; early diagnosis is mandatory to prevent its evolution into osteoarthrosis. In the early stages of patellar chondromalacia (I and II), the lesions originate in the deep cartilage layer and the joint surface is not affected. Arthroscopy can demonstrate joint surface changes only and give indirect information about deeper lesions. We investigated the yield of 2D FLASH MRI with 30 degrees flip angle and a dedicated coil in the diagnosis of patellar chondromalacia, especially in its early stages. Eighteen patients (mean age: 21 years) with clinically suspected patellar chondromalacia were examined with MRI; 13 of them were also submitted to arthroscopy. A 1.5 T unit with a transmit-and-receive extremity coil was used. We acquired T1 SE sequences (TR/TE: 500-700/15/20) and 2D T2* FLASH sequence (TR/TE/FA: 500-800/18/30 degrees). The field of view was 160-180 mm and the matrix 192 x 256, with 2-3 NEX. The images were obtained on the axial plane. The lesions were classified in 4 stages according to Shahriaree classification. Agreement between MR and arthroscopic findings was good in both early and advanced lesions in 12/13 cases. Early lesions appeared as hyperintense focal thickening of the hyaline cartilage (stage I) or as small cystic lesions within the cartilage and no articular surface involvement (stage II). The medial patellar facet was the most frequent site. Advanced lesions appeared as articular surface ulcerations, thinning and cartilage hypointensity (stage III); stage IV lesions presented as complete erosions of the hyaline cartilage and hypointense underlying bone. 2D FLASH MRI with 30 degrees flip angle can show the differences in water content in the cartilage and thus permit to detect early chondromalacia lesions in the deep cartilage.

  7. Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.

    Science.gov (United States)

    Chen, Xiaopeng; Walter, Kyla M; Miller, Galen W; Lein, Pamela J; Puschner, Birgit

    2018-06-01

    Environmental toxicants that interfere with thyroid hormone (TH) signaling can impact growth and development in animals and humans. Zebrafish represent a model to study chemically induced TH disruption, prompting the need for sensitive detection of THs. Simultaneous quantification of 3,3',5-triiodo-l-thyronine (T3), thyroxine (T4), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (3,5-T2) and 3,3'-diiodo-l-thyronine (3,3'-T2) in zebrafish larvae was achieved by ultra-performance liquid chromatography-tandem mass spectrometry in positive ion mode. Solid-phase extraction with SampliQ cartridges and derivatization with 3 m hydrochloric acid in n-butanol reduced matrix effects. Derivatized compounds were separated on an Acquity UPLC BEH C 18 column with mobile phases consisting of 0.1% acetic acid in deionized water and 0.1% acetic acid in methanol. The limits of detection ranged from 0.5 to 0.6 pg injected on column. The method was validated by evaluating recovery (77.1-117.2%), accuracy (87.3-123.9%) and precision (0.5-12.4%) using diluted homogenized zebrafish embryos spiked with all target compounds. This method was then applied to zebrafish larvae collected after 114 h of exposure to polychlorinated biphenyls (PCBs), including PCB 28, PCB 66 and PCB 95, or the technical mixture Aroclor 1254. Exposure to PCB 28 and PCB 95 increased the T4:T3 ratio and decreased the T3:rT3 ratio, demonstrating that this method can effectively detect PCB-induced alterations in THs. Copyright © 2018 John Wiley & Sons, Ltd.

  8. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Law, M; Yuan, J; Wong, O; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  9. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    International Nuclear Information System (INIS)

    Law, M; Yuan, J; Wong, O; Yu, S

    2016-01-01

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  10. Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T

    International Nuclear Information System (INIS)

    Attenberger, Ulrike I.; Wintersperger, Bernd J.; Sourbron, Steven P.; Reiser, Maximilian F.; Michaely, Henrik J.; Schoenberg, Stefan O.; Lodemann, Klaus-Peter

    2008-01-01

    The purpose was to evaluate the image quality of high-spatial resolution MRA of the renal arteries at 1.5 T after contrast-agent injection of 0.2 mmol/kg body weight (BW) in an interindividual comparison to 3.0 T after contrast-agent injection of 0.1 mmol/kg BW contrast agent (CA). After IRB approval and informed consent, 40 consecutive patients (25 men, 15 women; mean age 53.9 years) underwent MRA of the renal arteries either at a 1.5-T MR system with 0.2 mmol/kg BW gadobutrol or at a 3.0-T MR scanner with 0.1 mmol/kg BW gadobenate dimeglumine used as CA in a randomized order. A constant volume of 15 ml of these contrast agents was applied. The spatial resolution of the MRA sequences was 1.0 x 0.8 x 1.0 mm 3 at 1.5 T and 0.9 x 0.8 x 0.9 mm 3 at 3.0 T, which was achieved by using parallel imaging acceleration factors of 2 at 1.5 T and 3 at 3.0 T, respectively. Two radiologists blinded to the administered CA and the field strength assessed the image quality and the venous overlay for the aorta, the proximal and distal renal arteries independently on a four-point Likert-type scale. Phantom measurements were performed for a standardized comparison of SNR at 1.5 T and 3.0 T. There was no significant difference (p > 0.05) between the image quality at 3.0 T with 0.1 mmol/kg BW gadobenate dimeglumine compared to the exams at 1.5 T with 0.2 mmol/kg BW gadobutrol. The median scores were between 3 and 4 (good to excellent vessel visualization) for the aorta (3 at 1.5 T/4 at 3.0 T for reader 1 and 2). For the proximal renal arteries, median scores were 3 for the left and right renal artery at 1.5 T for both readers. At 3.0 T, median scores were 3 (left proximal renal artery) and 4 (right proximal renal artery) for reader 1 and 3 (left/right) for reader 2 at 3.0 T. For the distal renal arteries, median scores were between 2 and 3 at both field strengths (moderate and good) for both readers. The κ values for both field strengths were comparable and ranged between 0

  11. Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, Ulrike I.; Wintersperger, Bernd J.; Sourbron, Steven P.; Reiser, Maximilian F. [University Hospitals-Grosshadern, Ludwig-Maximilians-University Munich, Institute of Clinical Radiology, Munich (Germany); Michaely, Henrik J.; Schoenberg, Stefan O. [University Hospital Mannheim, University of Heidelberg, Institute of Clinical Radiology, Mannheim (Germany); Lodemann, Klaus-Peter [Bracco-Altana Pharma, Konstanz (Germany)

    2008-06-15

    The purpose was to evaluate the image quality of high-spatial resolution MRA of the renal arteries at 1.5 T after contrast-agent injection of 0.2 mmol/kg body weight (BW) in an interindividual comparison to 3.0 T after contrast-agent injection of 0.1 mmol/kg BW contrast agent (CA). After IRB approval and informed consent, 40 consecutive patients (25 men, 15 women; mean age 53.9 years) underwent MRA of the renal arteries either at a 1.5-T MR system with 0.2 mmol/kg BW gadobutrol or at a 3.0-T MR scanner with 0.1 mmol/kg BW gadobenate dimeglumine used as CA in a randomized order. A constant volume of 15 ml of these contrast agents was applied. The spatial resolution of the MRA sequences was 1.0 x 0.8 x 1.0 mm{sup 3} at 1.5 T and 0.9 x 0.8 x 0.9 mm{sup 3} at 3.0 T, which was achieved by using parallel imaging acceleration factors of 2 at 1.5 T and 3 at 3.0 T, respectively. Two radiologists blinded to the administered CA and the field strength assessed the image quality and the venous overlay for the aorta, the proximal and distal renal arteries independently on a four-point Likert-type scale. Phantom measurements were performed for a standardized comparison of SNR at 1.5 T and 3.0 T. There was no significant difference (p > 0.05) between the image quality at 3.0 T with 0.1 mmol/kg BW gadobenate dimeglumine compared to the exams at 1.5 T with 0.2 mmol/kg BW gadobutrol. The median scores were between 3 and 4 (good to excellent vessel visualization) for the aorta (3 at 1.5 T/4 at 3.0 T for reader 1 and 2). For the proximal renal arteries, median scores were 3 for the left and right renal artery at 1.5 T for both readers. At 3.0 T, median scores were 3 (left proximal renal artery) and 4 (right proximal renal artery) for reader 1 and 3 (left/right) for reader 2 at 3.0 T. For the distal renal arteries, median scores were between 2 and 3 at both field strengths (moderate and good) for both readers. The {kappa} values for both field strengths were comparable and ranged

  12. MRI (1,5 T) of traumatic extracerebral hematomas

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, D.; Grodd, W.; Voigt, K.

    1989-09-01

    The advantages of magnetic resonance imaging (MRI) in the diagnosis of subacute and chronic traumatic extracerebral hematomas are described. The characteristic changes in signal intensity for hematomas depend on the magnetic properties of hemoglobin and its derivatives, which shorten the relaxation times and decrease the homogeneity of the local magnetic field. MRI is superior in detecting and depicting the extent of small hematomas adjacent to the skull. Changes in signal intensity with time allow rough estimation of the age of a hematoma. Small hemorrhages were often found (missed by CT) that were contralateral to chronic subdural hematomas. (orig.).

  13. 26 CFR 1.274-5T - Substantiation requirements (temporary).

    Science.gov (United States)

    2010-04-01

    ... account statement is submitted by an employee to his employer or by an independent contractor to his... remainder of 1986. If other circumstances do not change (e.g., A does not obtain a second car for exclusive... amount which is attributable to each person participating in the event giving rise to the expenditure...

  14. 26 CFR 1.7872-5T - Exempted loans (temporary).

    Science.gov (United States)

    2010-04-01

    ... Federal tax liability of the borrower or the lender. (2) No exemption for tax avoidance loans. If a... principal purposes of so structuring the transaction is the avoidance of Federal tax, then the transaction will be recharacterized as a tax avoidance loan as defined in section 7872 (c)(1)(D). (b) List of...

  15. 26 CFR 1.469-5T - Material participation (temporary).

    Science.gov (United States)

    2010-04-01

    ... individual if and only if such activity— (i) Is a trade or business activity (within the meaning of § 1.469... of health, law, engineering, architecture, accounting, actuarial science, performing arts, or consulting; or (2) Any other trade or business in which capital is not a material income-producing factor. (e...

  16. Genome Sequence of Jumbo Phage vB_AbaM_ME3 of Acinetobacter baumanni.

    Science.gov (United States)

    Buttimer, Colin; O'Sullivan, Lisa; Elbreki, Mohamed; Neve, Horst; McAuliffe, Olivia; Ross, R Paul; Hill, Colin; O'Mahony, Jim; Coffey, Aidan

    2016-08-25

    Bacteriophage (phage) vB_AbaM_ME3 was previously isolated from wastewater effluent using the propagating host Acinetobacter baumannii DSM 30007. The full genome was sequenced, revealing it to be the largest Acinetobacter bacteriophage sequenced to date with a size of 234,900 bp and containing 326 open reading frames (ORFs). Copyright © 2016 Buttimer et al.

  17. Genome Sequence of Jumbo Phage vB_AbaM_ME3 of Acinetobacter baumanni

    OpenAIRE

    Buttimer, Colin; O?Sullivan, Lisa; Elbreki, Mohamed; Neve, Horst; McAuliffe, Olivia; Ross, R. Paul; Hill, Colin; O?Mahony, Jim; Coffey, Aidan

    2016-01-01

    Bacteriophage (phage) vB_AbaM_ME3 was previously isolated from wastewater effluent using the propagating host Acinetobacter baumannii DSM 30007. The full genome was sequenced, revealing it to be the largest Acinetobacter bacteriophage sequenced to date with a size of 234,900 bp and containing 326 open reading frames (ORFs).

  18. Measuring mumbo jumbo: A preliminary quantification of the use of jargon in science communication.

    Science.gov (United States)

    Sharon, Aviv J; Baram-Tsabari, Ayelet

    2014-07-01

    Leaders of the scientific community encourage scientists to learn effective science communication, including honing the skill to discuss science with little professional jargon. However, avoiding jargon is not trivial for scientists for several reasons, and this demands special attention in teaching and evaluation. Despite this, no standard measurement for the use of scientific jargon in speech has been developed to date. Here a standard yardstick for the use of scientific jargon in spoken texts, using a computational linguistics approach, is proposed. Analyzed transcripts included academic speech, scientific TEDTalks, and communication about the discovery of a Higgs-like boson at CERN. Findings suggest that scientists use less jargon in communication with a general audience than in communication with peers, but not always less obscure jargon. These findings may lay the groundwork for evaluating the use of jargon.

  19. Value of magnetic resonance mammographic at 1.5 T in the differential diagnosis of mastitis versus inflammatory carcinoma; Der Wert der MR-Mammographie in der Differentialdiagnostik von non-puerperaler Mastitis und inflammatorischem Mammakarzinom bei 1,5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Tomczak, R. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Rieber, A. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Zeitler, H. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Rilinger, N. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Kreienberg, R. [Klinik fuer Frauenheilkunde, Univ. Ulm (Germany); Brambs, H.J. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany)

    1996-08-01

    Purpose: The distinction between mastitis and inflammatory breast carcinoma is an important one. Current methods of evaluation including mammography, ultrasound and clinical examination do not enable this distinction. Dynamic magnetic resonance mammography (MRM) is a study with potential in this regard. Material and methods: 12 patients, in whom clinical examination, mammography and ultrasound could not distinguish between both diseases, were reviewed retrospectively by means of MRM using a 1.5 T Siemens Magnetom SP and a circular mamma coil. We used dynamic 3-D gradient echo sequences with a duration of one minute. Results: At present MRM cannot definitely distinguish between mastitis and inflammatory carcinoma, 80% of the inflammatory carcinomas were found to enhance more than 100% in the first minute, compared to 43% for mastitis. No other differences were seen. Conclusion: MRM proved useful in the follow-up of treated mastitis to demonstrate the success of antibiotic treatment of mastitis and to diagnose a histologically unconfirmed inflammatory carcinoma by means of a different follow-up. (orig.) [Deutsch] Ziel: Weder klinische Untersuchung, Ultraschall noch Mammographie erlauben die wichtige Unterscheidung zwischen non-puerperaler Mastitis und inflammatorischem Karzinom. Die Magnetresonanzmammographie (MRM) bietet sich als zusaetzliche Untersuchungsmethode zur Differenzierung an. Patienten und Methoden: Retrospektiv wurden 12 Patientinnen, bei denen klinische Untersuchung, Mammographie und Sonographie keine endgueltige Diagnose erbracht hatten, MR-mammographisch mit einem 1,5 Tesla Siemens Magnetom SP in der zirkulaeren Mammadoppelspule untersucht. Es wurden dynamische 3-D-Gradienten-Echo-Sequenzen von einer Minute Dauer verwendet. Ergebnisse: Auch die MRM leistete keinen sicheren Beitrag zur endgueltigen Diagnose. 80% der beobachteten inflammatorischen Karzinome gegenueber 43% der Mastitiden zeigten eine Kontrastmittelanreicherung ueber 100% in der ersten

  20. WISE BROWN DWARF BINARIES: THE DISCOVERY OF A T5+T5 AND A T8.5+T9 SYSTEM

    International Nuclear Information System (INIS)

    Gelino, Christopher R.; Kirkpatrick, J. Davy; Griffith, Roger L.; Marsh, Kenneth A.; Cushing, Michael C.; Eisenhardt, Peter R.; Mainzer, Amanda K.; Skrutskie, Michael F.; Wright, Edward L.

    2011-01-01

    The multiplicity properties of brown dwarfs are critical empirical constraints for formation theories, while multiples themselves provide unique opportunities to test evolutionary and atmospheric models and examine empirical trends. Studies using high-resolution imaging cannot only uncover faint companions, but they can also be used to determine dynamical masses through long-term monitoring of binary systems. We have begun a search for the coolest brown dwarfs using preliminary processing of data from the Wide-field Infrared Survey Explorer and have confirmed many of the candidates as late-type T dwarfs. In order to search for companions to these objects, we are conducting observations using the Laser Guide Star Adaptive Optics system on Keck II. Here we present the first results of that search, including a T5 binary with nearly equal mass components and a faint companion to a T8.5 dwarf with an estimated spectral type of T9.

  1. "Hello Jumbo!” The spatio-temporal rollout and traffic to a new grocery chain after acquisition

    NARCIS (Netherlands)

    van Lin, Arjen; Gijsbrechts, Els

    Grocery retailers increasingly use acquisitions to expand their presence. Such acquisitions are risky, especially when retailers decide to subsume the acquired stores under their own banner, which can take years and demands careful planning. We show how the dynamics of consumer valuations of the old

  2. Responses of Dendrobium 'darrenn glory' and Mokara 'calypso jumbo' orchids to 1-methylcyclopropene and aqueous ozone postharvest treatments

    Directory of Open Access Journals (Sweden)

    Parviz Almasi

    2015-01-01

    Full Text Available AbstractOrchids possess a very special place amongst ornamental plants. But high ethylene sensitivity and early flower senescence of orchid result in a short vase life and rapid quality deterioration which is of great concern for the growers, traders and consumers. An attempt was made to study the influence of 1-methylcyclopropene (1-MCP (0 and 300 nL L–1 and аquеous ozone (0 and 5.2 nL L–1 in prolonging vase life and maintaining quality of two cut orchid hybrids Dendrobium 'Darren Glory' (DDG and Mokara “Calypso Jumbo” (MCJ. Results showed that orchid hybrids exhibited differences in their ethylene sensitivity, vase life, 1-aminocyclopropane-1-carboxylic acid (ACC content and ACC oxidase activities. Pre-treatment with 1-MCP resulted in reduced ethylene production, vase life, ACC content and ACC oxidase activities, but increased bud opening %. Pre-treatment with аquеous ozone failed to influence all those parameters except bud opening %. Interaction effects of hybrid and 1-MCP were significant for ethylene production, hybrid and ozone for vas life, 1-MCP and ozone for bud opening %, and hybrid, 1-MCP and ozone for ethylene production and vase life. Aqueous ozone markedly contributed to the inhibition of microbial growth in vase solution. Pre-treatment of the cut orchid flowers with 300 nL L–11-MCP, followed by using 5.2 mg L–1 aqueous ozone as the vase solution could be recommended to maintain quality and extend vase life of both the DDG and MCJ orchid hybrids.

  3. Craniopharyngioma identification by CT and MR imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Eldevik, O.P. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Skalpe, I.O. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States)

    1995-03-01

    To compare the detectability of craniopharyngiomas by CT and MR imaging, preoperative CT and MR studies obtained within 16 days of each other were evaluated retrospectively in 9 patients. MR imaging demonstrated cystic and solid tumor components in all 9 tumors, and enhancement in the 7 tumors that were studied after contrast medium injection. MR imaging demonstrated a signal void consistent with calcification in 4 patients. Combining unenhanced and contrast medium-enhanced studies, CT also identified all the tumors. CT demonstrated cysts in 7 lesions, calcification in 7 and enhancement in 6 of the 7 lesions that received i.v. contrast medium. Calcification was better seen by CT than MR imaging, while MR imaging identified cystic tumor components not seen on CT. The contrast medium enhancement pattern was the same with the 2 modalities. MR imaging of the sellar region, including at least one contrast medium-enhanced sequence, should be sufficient in most instances to establish a preoperative diagnosis of craniopharyngioma. (orig.).

  4. Ga nuclear magnetic resonance study of UTGa5(T = Ni,Pt)

    International Nuclear Information System (INIS)

    Kato, Harukazu; Sakai, Hironori; Tokunaga, Yo; Tokiwa, Yoshihumi; Ikeda, Shugo; Onuki, Yoshichika; Kambe, Shinsaku; Walstedt, Russell E

    2003-01-01

    Ga nuclear magnetic resonance measurements have been carried out for the 5f antiferromagnets UNiGa 5 and UPtGa 5 . The transferred field at the Ga nuclei has been evaluated. The magnetic structure in the antiferromagnetic region has been confirmed from the microscopic point of view. The mechanism of the hyperfine interaction is discussed

  5. 26 CFR 1.132-5T - Working condition fringe-1985 through 1988 (temporary).

    Science.gov (United States)

    2010-04-01

    ... United States, a factor indicating a bona fide business-oriented security concern is threats on the life... is primarily personal. If, however, for bona fide business-oriented security concerns, the employee... have paid for the same mode of transportation absent the bona fide business-oriented security concerns...

  6. Investigation of the chain of 5T full-scale superconducting magnets

    International Nuclear Information System (INIS)

    Ageev, A.I.; Aleksandrov, G.M.; Aleksandrov, A.G.

    1987-01-01

    Bench investigations of the chain of dipoles with warm magnetic screen, connected in series, are being conducted in the framework of the IHEP program of the UNK superconducting magnet simulation. At the given stage conditions of accidental magnet transition to the normal state are being investigated. The study of processes of propagation of the normal phase, temperature fields and pressure growth dynamics, processes of energy and helium evacuation from magnet chain is given. Results of measuring electric and nonstationary processes in the chain during transition of one of superconducting magnets to the normal state are presented

  7. 26 CFR 1.6662-5T - Substantial and gross valuation misstatements under chapter 1 (temporary).

    Science.gov (United States)

    2010-04-01

    ..., DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Additions to the Tax, Additional... persons). (iii) Property. For purposes of this section, the term property refers to both tangible and... adjustments. For rules relating to the penalty imposed with respect to a substantial or gross valuation...

  8. Safety analysis report for packaging: neutron shipping cask, model 0.5T

    International Nuclear Information System (INIS)

    Peterson, R.T.

    1976-01-01

    The Safety Analysis Report for Packaging demonstrates that the neutron shipping cask can safely transport, in solid or powder form, all isotopes of uranium, plutonium, americium, curium, berkelium, californium, einsteinium, and fermium. The shipping cask and its contents are described. It also evaluates transport conditions, structural parameters (e.g., load resistance, pressure and impact effects, lifting and tiedown devices), and shielding. Finally, it discusses compliance with Chapter 0529 of the Energy Research and Development Administration Manual

  9. MR imaging of neonatal cerebral hemorrhage at 1.5 T

    International Nuclear Information System (INIS)

    McArdle, C.B.; Mehta, S.D.; Kulkarni, M.V.; Keeney, S.A.; Adcock, E.W. III.

    1987-01-01

    Twenty-three intracerebral hemorrhages (ICH) were seen in 60 neonates. Both T1- weighted (spin-echo, repetition time/echo time = 600-800/20 msec) and heavily T2- weighted sequences (SE = 2,500/80, 160) were necessary for detecting hemorrhage. MR imaging failed to disclose seven of ten IVH because of an irregular and full choroid, seen on US. US failed to show six ICH because of their small size (≤0.5 cm) or peripheral site. Twelve extracerebral hemorrhages were missed on US, and only one of three was seen on CT. In five other cases there were signal features of hemosidering from earlier hemorrhage. MR imaging is the best modality for visualizing ICH because of its high sensitivity, specificity, and the persistence of hemorrhagic signal for weeks to months longer than on US or CT

  10. Interneuronal systems of the cervical spinal cord assessed with BOLD imaging at 1.5 T

    International Nuclear Information System (INIS)

    Stracke, C.P.; Schoth, F.; Moeller-Hartmann, W.; Krings, T.; Pettersson, L.G.

    2005-01-01

    The purpose of this study was to investigate if functional activity with spinal cord somatosensory stimulation can be visualized using BOLD fMRI. We investigated nine healthy volunteers using a somatosensory stimulus generator. The stimuli were applied in three different runs at the first, third, and fifth finger tip of the right hand, respectively, corresponding to dermatomes c6, c7, and c8. The stimuli gave an increase of BOLD signal (activation) in three different locations of the spinal cord and brain stem. First, activations could be seen in the spinal segment corresponding to the stimulated dermatome in seven out of nine volunteers for c6 stimulation, two out of eight for c7, and three out of eight for c8. These activations were located close to the posterior margin of the spinal cord, presumably reflecting synaptic transmission to dorsal horn interneurons. Second, activation in the medulla oblongata was evident in four subjects, most likely corresponding to the location of the nucleus cuneatus. The third location of activation, which was the strongest and most reliable observed was inside the spinal cord in the c3 and c4 segments. Activation at these spinal levels was almost invariably observed independently of the dermatome stimulated (9/9 for c6, 8/8 for c7, and 7/8 for c8 stimulation). These activations may pertain to an interneuronal system at this spinal level. The results are discussed in relation to neurophysiological studies on cervical spinal interneuronal pathways in animals and humans. (orig.)

  11. 26 CFR 1.280F-5T - Leased property (temporary).

    Science.gov (United States)

    2010-04-01

    ... incidental leasing activity is insufficient. For example, a person leasing only one passenger automobile during a taxable year is not regularly engaged in the business of leasing automobiles. In addition, an... listed property leased or held for leasing by any person regularly engaged in the business of leasing...

  12. 26 CFR 1.103(n)-5T - Certification of no consideration for allocation (temporary).

    Science.gov (United States)

    2010-04-01

    ... any bribe, gift, gratuity, or direct or indirect contribution to any political campaign. With respect... willfully making an allocation in consideration of any bribe, gift, gratuity, or direct or indirect... allocation of any portion of the State ceiling in consideration of any bribe, gift, gratuity, or direct or...

  13. TOWARDS A GLOBAL 2l5 T CENTURY AFRICAN POPULAR MUSIC

    African Journals Online (AJOL)

    implications of this development for African music and musicians, with a ... carried not only men, women and children, but also their gods, beliefs and folklore". Considering the ... "population movements that followed territorial expansion, wars,.

  14. MRI of focal liver lesions using a 1.5T turbo-spinecho technique compared with spinecho technique; MRT fokaler Leberlaesionen bei 1,5T Turbo-Spinecho im Vergleich mit der Spinecho-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, S. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Vogl, T.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Fischer, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steger, W. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Neuhaus, P. [Chirurgische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Keck, H. [Chirurgische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1995-08-01

    In our study 35 patients with suspected focal liver lesions were examined. Standardised imaging protocol included a conventional T{sub 2}-weighted SE sequence (T{sub R}/T{sub E} = 2000/90/45, acquisition time = 10.20) as well as a T{sub 2}-weighted TSE sequence (T{sub R}/T{sub E} = 4700/90, acquisition time = 6.33). Calculation of S/N and C/N ratio as a basis of quantitative evaluation was done using standard methods. A diagnostic score was implemented to enable qualitative assessment. In 7% (n=2) the TSE sequence enabled detection of further liver lesions showing a size of less than 1 cm in diameter. Comparing anatomical details the TSE sequence was superior. S/N and C/N ratio of anatomic and pathologic structures of the TSE sequence were higher compared to results of the SE sequence. (orig./MG) [Deutsch] In einer prospektiven Studie wurden 35 Patienten mit fokalen Leberlaesionen untersucht. Das standardisierte Untersuchungsschema der Studie umfasste eine konventionelle SE-Sequenz mit T{sub R}/T{sub E} = 2000/90/45 (Akquisitionszeit = 10,20 min) sowie eine TSE-Sequenz mit T{sub R}/T{sub E} = 4700/90 (Akquisitionszeit = 6.33 min). Die Berechnung des S/R- sowie der K/R-Quotienten als Grundlage des quantitativen Vergleichs erfolgte nach Standardmethoden. Der qualitative Vergleich beider Sequenzen erfolgte durch Einschaetzung der Bildqualitaet anhand eines Stufenschemas. In 7% (n=2) konnten mit Hilfe der TSE-Sequenz mehr suspekte Laesionen detektiert werden. Ein Vergleich der Darstellung der anatomischen Detailerkennbarkeit zeigte Ueberlegenheit der TSE-Sequenz. Die S/R-Quotienten und K/R-Quotienten bezogen auf anatomische und pathologische Strukturen wiesen fuer die Turbo-Spinecho-Sequenz hoehere Werte auf. (orig./MG)

  15. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  16. The 5T mouse multiple myeloma model: Absence of c-myc oncogene rearrangement in early transplant generations

    NARCIS (Netherlands)

    Radl, J.; Punt, Y.A.; Enden-Vieveen, M.H.M. van den; Bentvelzen, P.A.J.; Bakkus, M.H.C.; Akker T., W. van den; Benner, R.

    1990-01-01

    Consistent chromosomal translocations involving the c-myc cellular oncogene and one of the three immunoglobulin loci are typical for human Burkitt's lymphoma, induced mouse plasmacytoma (MPC) and spontaneously arising rat immunocytoma (RIC). Another plasma cell malignancy, multiple myeloma (MM),

  17. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  18. Soft-tissue and bone lesions examined with 1.5-T MR imaging and Gd-DOTA

    International Nuclear Information System (INIS)

    VonSchulthess, G.K.; Kuoni, W.; Wuthrich, R.; Duewell, S.; Thurnher, S.; Marincek, B.

    1988-01-01

    Fifteen patients with soft-tissue masses or bone lesions underwent 16 MR imaging examinations with gadolinium-DOTA, a new MR contrast agent. T1- and T2-weighted precontrast sequences were obtained. The contrast agent was injected in a concentration of 0.1 mmol/kg without any untoward effects. After contrast examination, one or two T1-weighted sequences were obtained. Contrast medium application improved the distinction between lesion and edema in four of seven cases, between the lesion and central necrosis in seven of eight cases, and between the lesion, and the surrounding tissues in four of 12 cases. In eight of 12 cases, additional structures within the lesion were noted after Gd-DOTA enhancement. Of particular benefit was the use of contrast media to evaluate the vascularization of the lesion (in 12 of 14 cases)

  19. The imaging of abducens nerve in normal volunteers and palsy cases using 1.5T MRI 3-D CISS

    International Nuclear Information System (INIS)

    Takahashi, Mayu; Ezuka, Isamu; Kakinuma, Kenichi; Yamada, Haruyuki; Harada, Atsukuni; Kanazawa, Tsutomu

    2002-01-01

    The purpose of this study was to identify the cisternal segment of the abducens nerve and to investigate its anatomical features using three-dimensional Fourier transform constructive interference in steady-state (3-D CISS) sequence with a 1.5-tesla magnetic resonance (MR) imaging system. Images of abducens nerve palsy were also studied. Using this imaging system, the following procedures were performed to identify the abducens nerve. First, gray scale of the original images was inverted (inverted image). Second, Dollero's canal was identified, which contains the abducens nerve, and third, the nerve was followed to the root exit zone with a multiple-planar reconstruction method. Twenty-one volunteers and 3 patients with abducens nerve palsies participated in this study and following results were derived: all nerves in volunteers were clearly identified in the coronal and sagittal planes, the images closely resembled autopsy cases, seven nerves in asymptomatic cases were remarkably distorted by the vessels, and the cause of the palsy was not clear by their shapes in the images; this technique, however, can play a great role in evaluating abducens nerve palsy. (author)

  20. Mutations in Cytosine-5 tRNA Methyltransferases Impact Mobile Element Expression and Genome Stability at Specific DNA Repeats

    Directory of Open Access Journals (Sweden)

    Bianca Genenncher

    2018-02-01

    Full Text Available The maintenance of eukaryotic genome stability is ensured by the interplay of transcriptional as well as post-transcriptional mechanisms that control recombination of repeat regions and the expression and mobility of transposable elements. We report here that mutations in two (cytosine-5 RNA methyltransferases, Dnmt2 and NSun2, impact the accumulation of mobile element-derived sequences and DNA repeat integrity in Drosophila. Loss of Dnmt2 function caused moderate effects under standard conditions, while heat shock exacerbated these effects. In contrast, NSun2 function affected mobile element expression and genome integrity in a heat shock-independent fashion. Reduced tRNA stability in both RCMT mutants indicated that tRNA-dependent processes affected mobile element expression and DNA repeat stability. Importantly, further experiments indicated that complex formation with RNA could also contribute to the impact of RCMT function on gene expression control. These results thus uncover a link between tRNA modification enzymes, the expression of repeat DNA, and genomic integrity.

  1. Microstructural evaluation of Ti-35Nb-7,5 T alloy deformed by cold rolling and annealed

    International Nuclear Information System (INIS)

    Giudice, M.L.C.; Hayama, A.O.F.; Button, S.T.; Caram, R.

    2010-01-01

    This work presents the main results of microstructural characterization of Ti- 35Nb-7.5Ta (% in weight) deformed by cold rolling and annealed. Samples were obtained by electric arc melting, heat treated at 1000 deg C for 8 hours and water quenched. Samples were deformed by cold rolling in multiple passes up to a maximum reduction of 84%. Deformed samples were encapsulated in quartz under vacuum and annealed at 600, 700 e 800 deg C, in variable times and water quenched. Characterization was carried out using light optical microscopy, X-ray diffraction, Vickers hardness test and acoustic emission measurements to determine the Young's modulus. The results show the orientation occurrence of the martensitic phase in relation to the cold rolling direction in deformed samples. In samples annealed at 600 deg C recovery is predominant and samples annealed at 800 deg C for 60 min are fully recrystallized. (author)

  2. Hyaline articular cartilage: relaxation times, pulse-sequence parameters and MR appearance at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Chalkias, S.M. [Dept. of Radiology, A.H.E.P.A. General Hospital of the Aristotelian Univ., Thessaloniki (Greece); Pozzi-Mucelli, R.S. [Dept. of Radiology, Univ. of Trieste (Italy); Pozzi-Mucelli, M. [Orthopaedic Clinic, Univ. of Trieste (Italy); Frezza, F. [Dept. of Radiology, Univ. of Trieste (Italy); Longo, R. [Dept. of Radiology, Univ. of Trieste (Italy)

    1994-08-01

    In order to optimize the parameters for the best visualization of the internal architecture of the hyaline articular cartilage a study both ex vivo and in vivo was performed. Accurate T1 and T2 relaxation times of articular cartilage were obtained with a particular mixed sequence and then used for the creation of isocontrast intensity graphs. These graphs subsequently allowed in all pulse sequences (spin echo, SE and gradient echo, GRE) the best combination of repetition time (TR), echo time (TE) and flip angle (FA) for optimization of signal differences between MR cartilage zones. For SE sequences maximum contrast between cartilage zones can be obtained by using a long TR (> 1,500 ms) with a short TE (< 30 ms), whereas for GRE sequences maximum contrast is obtained with the shortest TE (< 15 ms) combined with a relatively long TR (> 400 ms) and an FA greater than 40 . A trilaminar appearance was demonstrated with a superficial and deep hypointense zone in all sequences and an intermediate zone that was moderately hyperintense on SE T1-weighted images, slightly more hyperintense on proton density Rho and SE T2-weighted images and even more hyperintense on GRE images. (orig.)

  3. Study of a 5T Research Dipole Insert-Magnet Using an Anisotropic ReBCO Roebel Cable

    NARCIS (Netherlands)

    van Nugteren, J.; Kirby, G.A.; de Rijk, G.; Rossi, L.; ten Kate, Herman H.J.; Dhalle, Marc M.J.

    2015-01-01

    A design study is presented for the coil layout of the EUCARD-2 Five Tesla HTS Research (FeaTHeR) magnet. The angular dependence of the critical current in the used ReBCO Roebel cable is taken into account. This leads to a new coil layout named aligned block. This layout makes optimal use of the

  4. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  5. 26 CFR 1.905-5T - Foreign tax redeterminations and currency translation rules for foreign tax redeterminations...

    Science.gov (United States)

    2010-04-01

    ... the rate of exchange for the date of the payment of the foreign tax. Refunds of such taxes shall be translated into dollars at the rate of exchange for the date of the refund. (2) Foreign taxes deemed paid on... actual distribution and refunds of such taxes shall be translated into dollars at the rate of exchange...

  6. Study of a 5T Research Dipole Insert-Magnet using an Anisotropic ReBCO Roebel Cable

    CERN Document Server

    Van Nugteren, J; De Rijk, G; Rossi, L; Ten Kate, H H J; Dhallé, M M J

    2015-01-01

    A design study is presented for the coil layout of the EuCARD-2 Fiver Tesla HTS Research (FeaTHeR) magnet. The angular dependence of the critical current in the used ReBCO Roebel cable is taken into account. This leads to a new coil layout named aligned block. This layout makes optimal use of the anisotropy of the ReBCO coated conductor, by aligning all tapes with the magnetic field lines. Both two dimensional cross sections and three dimensional coil layouts are presented. In the layouts the magnetic field angle is highest at the edges of the cable causing a large variation of the critical current over its width. Different approaches to the calculation of the critical current, with and without current sharing in and between the tapes, are presented. The values are compared to the values found using a non-linear network model of the cable, in which the electrical properties of the elements are calculated as a function of magnetic field and magnetic field angle. The model also includes electrical contact betwe...

  7. MRI of focal liver lesions using a 1.5T turbo-spinecho technique compared with spinecho technique

    International Nuclear Information System (INIS)

    Steiner, S.; Vogl, T.J.; Fischer, P.; Steger, W.; Neuhaus, P.; Keck, H.

    1995-01-01

    In our study 35 patients with suspected focal liver lesions were examined. Standardised imaging protocol included a conventional T 2 -weighted SE sequence (T R /T E = 2000/90/45, acquisition time = 10.20) as well as a T 2 -weighted TSE sequence (T R /T E = 4700/90, acquisition time = 6.33). Calculation of S/N and C/N ratio as a basis of quantitative evaluation was done using standard methods. A diagnostic score was implemented to enable qualitative assessment. In 7% (n=2) the TSE sequence enabled detection of further liver lesions showing a size of less than 1 cm in diameter. Comparing anatomical details the TSE sequence was superior. S/N and C/N ratio of anatomic and pathologic structures of the TSE sequence were higher compared to results of the SE sequence. (orig./MG) [de

  8. 78 FR 49584 - Self-Regulatory Organizations; BOX Options Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-08-14

    ... offering pricing specific to Jumbo SPY Options because this is a new options product offered only on the... trading a new options product, Jumbo SPY Options,\\5\\ on May 10, 2013.\\6\\ Except for the difference in the... for Jumbo SPY Options to $0.00. This is a new options product and assessing a lower fee than would...

  9. Image reconstruction of gold- and poly markers on 1.5T and 3T diffusion-weighted MRI and CBCT

    DEFF Research Database (Denmark)

    Rylander, Susanne; Haack, Søren; Muren, Ludvig

    factor=2, 1.5/3T; b-values=600,1000s/mm2, TE=91/70ms, TR=2086-2514/1800ms, acquired resolution=2.31/2.25mm/pxl, slice thickness=4/4mm). A co-registration with CT images (image resolution=0.35mm/pxl, slice thickness=0.7mm) was performed to both T1W- and CBCT images (image resolution=0.88mm/pxl, slice...

  10. Two-dimensional MRI at 1.5 and 0.5 T versus CT myelography in the diagnosis of cervical radiculopathy

    International Nuclear Information System (INIS)

    Bartlett, R.J.V.; Rowland Hill, C.A.; Devlin, R.; Gardiner, E.D.

    1996-01-01

    A prospective comparison was made of standard two-dimensional MRI sequences, at both high and midfield strength, with CT myelography in 23 patients with cervical spondylosis. MRI is adequate for assessment of cord compression, where high field strength is superior to midfield strength. MRI using 4-mm sections is inadequate for presurgical assessment of root compression. It remains to be proven whether thin-section white-CSF volume sequences or gadolinium-enhanced volume studies can replace CT myelography. (orig.). With 6 tabs

  11. Gamma and Proton-Induced Dark Current Degradation of 5T CMOS Pinned Photodiode 0.18 mu{m} CMOS Image Sensors

    Science.gov (United States)

    Martin, E.; Nuns, T.; David, J.-P.; Gilard, O.; Vaillant, J.; Fereyre, P.; Prevost, V.; Boutillier, M.

    2014-02-01

    The radiation tolerance of a 0.18 μm technology CMOS commercial image sensor has been evaluated with Co60 and proton irradiations. The effects of protons on the hot pixels and dynamic bias and duty cycle conditions during gamma irradiations are studied.

  12. Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao; Zhong, Yu-min; Zhang, Hong; Lin, Yi; Zhu, Ming [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China); Nie, Quan-min; Guo, Lie-mei; Yang, Xi [Shanghai Jiao Tong University School of Medicine, Department of Neurosurgery Ren Ji Hospital, Shanghai (China); Chen, Wei-bo; Dai, Yong-ming [Philips Healthcare, Shanghai (China); Xu, Jian-rong [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ren Ji Hospital, Shanghai (China)

    2016-01-15

    To investigate the feasibility of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the diagnosis of skull fractures. The skull fracture models of ten Bama pigs and 364 patients with craniocerebral trauma were subjected to computed tomography (CT), UTE and conventional MRI sequences. The accuracy of UTE imaging in skull fracture diagnosis was analysed using receiver operating characteristic (ROC) curve analysis, McNemar's test and Kappa values. Differences among CT, UTE imaging and anatomical measurement (AM) values for linear fractures (LFs) and depressed fractures (DFs) were compared using one-way ANOVA and a paired-samples t-test. UTE imaging clearly demonstrated skull structures and fractures. The accuracy, validity and reliability of UTE MRI were excellent, with no significant differences between expert readings (P > 0.05; Kappa, 0.899). The values obtained for 42 LFs and 13 DFs in the ten specimens were not significantly different among CT, UTE MRI and AMs, while those obtained for 55 LFs and ten DFs in 44 patients were not significantly different between CT and UTE MRI (P > 0.05). UTE MRI sequences are feasible for the evaluation of skull structures and fractures, with no radiation exposure, particularly for paediatric and pregnant patients. (orig.)

  13. Effect of b value and pre-admission of contrast on diagnostic accuracy of 1.5-T breast DWI : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Dorrius, Monique D.; Dijkstra, Hildebrand; Oudkerk, Matthijs; Sijens, Paul E.

    2014-01-01

    To evaluate the effect of the choice of b values and prior use of contrast medium on apparent diffusion coefficients (ADCs) of breast lesions derived from diffusion-weighted imaging (DWI), and on the discrimination between benign and malignant lesions. A literature search of relevant DWI studies was

  14. Diagnostic accuracy of diffusion-weighted imaging with conventional MR imaging for differentiating complex solid and cystic ovarian tumors at 1.5T

    Directory of Open Access Journals (Sweden)

    Zhang Ping

    2012-11-01

    Full Text Available Abstract Background Preoperative characterization of complex solid and cystic adnexal masses is crucial for informing patients about possible surgical strategies. Our study aims to determine the usefulness of apparent diffusion coefficients (ADC for characterizing complex solid and cystic adnexal masses. Methods One-hundred and 91 patients underwent diffusion-weighted (DW magnetic resonance (MR imaging of 202 ovarian masses. The mean ADC value of the solid components was measured and assessed for each ovarian mass. Differences in ADC between ovarian masses were tested using the Student’s t-test. The receiver operating characteristic (ROC was used to assess the ability of ADC to differentiate between benign and malignant complex adnexal masses. Results Eighty-five patients were premenopausal, and 106 were postmenopausal. Seventy-four of the 202 ovarian masses were benign and 128 were malignant. There was a significant difference between the mean ADC values of benign and malignant ovarian masses (p -3 mm2/s may be the optimal one for differentiating between benign and malignant tumors. Conclusions A high signal intensity within the solid component on T2WI was less frequently in benign than in malignant adnexal masses. The combination of DW imaging with ADC value measurements and T2-weighted signal characteristics of solid components is useful for differentiating between benign and malignant ovarian masses.

  15. Magnetic order and crystal fields in the Pnma phases of Tm2BaTO5(T=Co and Ni)

    International Nuclear Information System (INIS)

    Harker, S.J.; Stewart, G.A.

    2000-01-01

    The magnetic ordering and crystal field interactions of the Pnma phases of both Tm 2 BaCoO 5 and Tm 2 BaNiO 5 are investigated by 169 Tm Moessbauer spectroscopy and the temperature-dependent hyperfine interactions are compared with those obtained elsewhere for Tm 2 BaCuO 5 . The Pnma phases are shown to order magnetically at temperatures of 3.5(2) K (Tm 2 BaCoO 5 ) and 4.85(5) K (Tm 2 BaNiO 5 ), the order being induced by the transition metal. For Tm 2 BaNiO 5 an additional first-order transition observed at T≤1.4 K is identified with the independent magnetic order of the thulium sub-lattice. (orig.)

  16. Effects of a static magnetic field of 3.5 T on reproductive behaviour of mice, embryonic and foetal development and some haematological parameters

    International Nuclear Information System (INIS)

    Zimmermann, B.; Hentschel, D.

    1987-01-01

    To investigate possibilities of magnetic resonance imaging at high magnetic fields in humans, a whole-body magnet with a magnetic field density of 4 T was developed. Due to the few data that are available at present on biological effects and side effects of such high fields, a reproduction experiment with NMRI mice was performed using a crossover design. The mice were allowed to mate during a 7-day period within the field or after their stay in the field. The number of pregnant mice and foetuses were recorded and compared to the controls. Another group was held within the magnetic field during the whole period of pregnancy until day 18, one day before delivery. In all groups, development of the foetuses was studied. Additionally, haematological parameters of the males and females were estimated and necroscopy was performed. Brains, lungs and optical nerves were investigated using pathohistological techniques. It could be shown that in case of mating within the magnetic field, the number of pregnant mice was considerably reduced. This effect was, however, completely reversible if mating occurred after the stay in the field. Malformations retardations or an increased number of resorptions were never found. The haematological parameters were, in general, not changed. Necroscopy as well as pathohistological investigations showed no pathological alterations. Therefore, it appears that whereas high magnetic fields reduce the activity of mating behaviour, they do not exert any influence on physiological parameters. (orig.) [de

  17. Diseño de metodologías para la adquisición de resonancia magnética funcional a 1,5t

    OpenAIRE

    Guiu Hernández, Esther

    2009-01-01

    Projecte fet en col.laboració amb Pontificia Universidad Católica de Chile. Escuela de Ingeniería La resonancia magnética funcional (fMRI) es una técnica mediante la cual se puede mapear el cerebro, tanto anatómica como fisiológicamente, sin necesidad de realizar estudios invasivos. A fin de obtener mapas de activación cerebral, el sujeto en estudio debe realizar alguna tarea o estar expuesto a un estímulo externo. Paralelamente se adquieren, mediante resonancia magnética, una gran cantida...

  18. Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T

    International Nuclear Information System (INIS)

    Wolff, Andrew B.; Pesce, Lorenzo L.; Wu, Jim S.; Smart, L.R.; Medvecky, Michael J.; Haims, Andrew H.

    2009-01-01

    At our institution, fast spin-echo (FSE) proton density (PD) imaging is used to evaluate articular cartilage, while conventional spin-echo (CSE) T1-weighted sequences have been traditionally used to characterize meniscal pathology. We sought to determine if FSE PD-weighted sequences are equivalent to CSE T1-weighted sequences in the detection of meniscal tears, obviating the need to perform both sequences. We retrospectively reviewed the records of knee arthroscopies performed by two arthroscopy-focused surgeons from an academic medical center over a 2-year period. The preoperative MRI images were interpreted independently by two fellowship-trained musculoskeletal radiologists who graded the sagittal CSE T1 and FSE PD sequences at different sittings with grades 1-5, where 1 = normal meniscus, 2 = probable normal meniscus, 3 indeterminate, 4 = probable torn meniscus, and 5 = torn meniscus. Each meniscus was divided into an anterior and posterior half, and these halves were graded separately. Operative findings provided the gold standard. Receiver operating characteristic (ROC) analysis was performed to compare the two sequences. There were 131 tears in 504 meniscal halves. Using ROC analysis, the reader 1 area under curve for FSE PD was significantly better than CSE T1 (0.939 vs. 0.902, >95% confidence). For reader 2, the difference met good criteria for statistical non-inferiority but not superiority (0.913 for FSE PD and 0.908 for CSE T1; >95% non-inferiority for difference at most of -0.027). FSE PD-weighted sequences, using our institutional protocol, are not inferior to CSE T1-weighted sequences for the detection of meniscal tears and may be superior. (orig.)

  19. Effect of b value and pre-admission of contrast on diagnostic accuracy of 1.5-T breast DWI: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dorrius, Monique D.; Dijkstra, Hildebrand [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Groningen (Netherlands); University of Groningen / University Medical Center Groningen, Department of Radiology, EB44, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Groningen (Netherlands); Sijens, Paul E. [University of Groningen / University Medical Center Groningen, Department of Radiology, EB44, Groningen (Netherlands)

    2014-11-15

    To evaluate the effect of the choice of b values and prior use of contrast medium on apparent diffusion coefficients (ADCs) of breast lesions derived from diffusion-weighted imaging (DWI), and on the discrimination between benign and malignant lesions. A literature search of relevant DWI studies was performed. The accuracy of DWI to characterize lesions by using b value ≤600 s/mm{sup 2} and b value >600 s/mm{sup 2} was presented as pooled sensitivity and specificity, and the ADC was calculated for both groups. Lesions were pooled as pre- or post-contrast DWI. Of 198 articles, 26 met the inclusion criteria. Median ADCs were significantly higher (13.2-35.1 %, p < 0.001) for the group of b values ≤600 s/mm{sup 2} compared to >600 s/mm{sup 2}. The sensitivity in both groups was similar (91 % and 89 %, p = 0.495) as well as the specificity (75 % and 84 %, p = 0.237). Contrast medium had no significant effects on the ADCs (p ≥ 0.08). The differentiation between benign and malignant lesions was optimal (58.4 %) for the combination of b = 0 and 1,000 s/mm{sup 2}. The wide variety of b value combinations applied in different studies significantly affects the ADC of breast lesions and confounds quantitative DWI. If only a couple of b values are used, those of b = 0 and 1,000 s/mm{sup 2} are recommended for the best improvement of differentiating between benign and malignant lesions. (orig.)

  20. 26 CFR 1.367(a)-5T - Property subject to section 367(a)(1) regardless of use in trade or business (temporary).

    Science.gov (United States)

    2010-04-01

    ... constitutes foreign goodwill or going concern value, as defined in § 1.367(a)-1T(d)(5)(iii). For rules concerning transfers of intangible property pursuant to section 351 or 361, see section 367(d) and § 1.367(d...

  1. A Fully Integrated Dual-Channel On-Coil CMOS Receiver for Array Coils in 1.5-10.5 T MRI.

    Science.gov (United States)

    Sporrer, Benjamin; Wu, Lianbo; Bettini, Luca; Vogt, Christian; Reber, Jonas; Marjanovic, Josip; Burger, Thomas; Brunner, David O; Pruessmann, Klaas P; Troster, Gerhard; Huang, Qiuting

    2017-12-01

    Magnetic resonance imaging (MRI) is among the most important medical imaging modalities. Coil arrays and receivers with high channel counts (16 and more) have to be deployed to obtain the image quality and acquisition speed required by modern clinical protocols. In this paper, we report the theoretical analysis, the system-level design, and the circuit implementation of the first receiver IC (RXIC) for clinical MRI fully integrated in a modern CMOS technology. The dual-channel RXIC sits directly on the sensor coil, thus eliminating any RF cable otherwise required to transport the information out of the magnetic field. The first stage LNA was implemented using a noise-canceling architecture providing a highly reflective input used to decouple the individual channels of the array. Digitization is performed directly on-chip at base-band by means of a delta-sigma modulator, allowing the subsequent optical transmission of data. The presented receiver, implemented in a CMOS technology, is compatible with MRI scanners up to . It reaches sub- noise figure for MRI units and features a dynamic range up to at a power consumption below per channel, with an area occupation of . Mounted on a small-sized printed circuit board (PCB), the receiver IC has been employed in a commercial MRI scanner to acquire in-vivo images matching the quality of traditional systems, demonstrating the first step toward multichannel wearable MRI array coils.

  2. 26 CFR 1.163-5T - Denial of interest deduction on certain obligations issued after December 31, 1982, unless issued...

    Science.gov (United States)

    2010-04-01

    ... assets, and arranges for the sale to investors of bearer certificates of interest in the trust which do...) for purposes of section 163(f)(2) (A) and (B) does not affect the determination of whether bearer... REMIC as its only asset, and arranges for the sale to investors of regular interests in the REMIC in...

  3. Memory CD4(+)CCR5(+) T cells are abundantly present in the gut of newborn infants to facilitate mother-to-child transmission of HIV-1

    NARCIS (Netherlands)

    Bunders, Madeleine J.; van der Loos, Chris M.; Klarenbeek, Paul L.; van Hamme, John L.; Boer, Kees; Wilde, Jim C. H.; de Vries, Niek; van Lier, Rene A. W.; Kootstra, Neeltje; Pals, Steven T.; Kuijpers, Taco W.

    2012-01-01

    Despite potential clinical importance, target cells for mother-to-child transmission of HIV-1 have not yet been identified. Cord blood-derived CD4(+) T cells are largely naive and do not express CCR5, the mandatory coreceptor for transmitted HIV-1 R5 strains in infants. In the present study, we

  4. Post irradiation fatigue tests of type 316 LN stainless steel. Final report for the ITER Task T511, Subtask 1. European Technology Programme Task GB5-T217

    Energy Technology Data Exchange (ETDEWEB)

    Norring, K.; Koenig, M

    2002-01-01

    The main objective of this Subtask was to estimate the corrosion fatigue behaviour of 316L Stainless Steel (SS) and SS/SS joints, and to check among others the influence of irradiation. Joints were produced by solid Hot Isostatic Pressure (HIP) and powder HIP. Conventional material was used for comparison. The specimens were supplied by EFDA and were irradiated to 4 dpa in Dimitrovgrad (Russia). All specimens were tested at 150 deg C in hydrogenated high purity water. Testing was performed with a stepwise decrease in {delta}K keeping K{sub max} constant. The crack growth rates of irradiated as well as unirradiated specimens tested earlier are of the same magnitude, around 2x10{sup -5} mm/cycle at {delta}K= 18 MPa{radical}m. Thus, irradiation does not seem to enhance the fatigue crack growth rate, at least not up to irradiation levels of 4 dpa. But it is worth noting that the exponents in the da/dN versus {delta}K equation, also known as Paris' law, seems to fall within two areas, either around 3.5 or just below 2. Both Powder HIPed and Solid HIPed specimens are found in both groups. The reason for this is not evident. The fracture surfaces of the specimens show typical fatigue appearance.

  5. Dynamic Gd-DTPA enhanced breath-hold 1.5 t MRI of normal lungs and patients with interstitial lung disease and pulmonary nodules: preliminary results

    International Nuclear Information System (INIS)

    Semelka, R.C.; Maycher, B.; Shoenut, J.P.; Kroeker, R.; Griffin, P.; Lertzman, M.

    1992-01-01

    A FLASH technique was used, which encompassed the entire thorax in the transverse plane, before and after dynamic intravenous injection of godalinium DTPA (Gd-DTPA) to study 7 patients with normal lungs, 12 patients with interstitial lung disease (ILD), and 11 patients with pulmonary nodules. Comparative CT studies were obtained within 2 weeks of the MRI study in the patients with lung disease. Quantitative signal intensity (SI) measurements were performed. Qualitative evaluation of lung parenchyma was determined in a prospective blinded fashion, and in the normal group comparison was made with the CT images. In normal patients, SI of lung parenchyma increased by 7.7±1.3%. On precontrast images, second-order pulmonary branchings were visible while post-contrast, fifth- to sixth-order branches were apparent. In patients with ILD, interstitial changes enhanced to a variable extent, increases in SI ranging from minimal (49.9%) to substantial (308.4%). Detection of pulmonary nodules improved following contrast injection. The minimum lesion size detectable decreased from 8 mm precontrast to 5 mm post-contrast. Percentage contrast enhancement was greater for malignant nodules (124.2±79.7%) than benign nodules (5.8±4.7%) (p<0.01). (orig.)

  6. Anti pp elastic scattering at 30 GeV/c incident momentum in the momentum transfer range 0. 5<-t<5. 8(GeV/c)/sup 2/

    Energy Technology Data Exchange (ETDEWEB)

    Asa' d, Z.; Coupland, M.; Davis, D.G.; Duff, B.G.; Fearnley, T.; Heymann, F.F.; Imrie, D.C.; Lush, G.J.; Phillips, M. (University Coll., London (UK)); Baglin, A.

    1983-10-27

    The anti pp elastic differential cross section at 30 GeV/c incident momentum has been measured in a two-arm spectrometer experiment (WA7) at the CERN SPS. The vertical stroketvertical stroke-range covered extends from 0.5 to 5.8 (GeV/c)/sup 2/. A pronounced dip-bump structure is observed, with a sharp minimum around vertical stroketvertical strokeapprox.=1.7 (GeV/c)/sup 2/. The results are compared with existing anti pp data at lower energies and with our earlier anti pp data at 50 GeV/c. A number of model predictions are discussed. We also compare the anti pp 30 GeV/c differential cross section with that of pp at the same momentum. Finally, the energy dependence of the anti pp fixed-vertical stroketvertical stroke differential cross section in the incident momentum range 3.6 to 50 GeV/c is presented.

  7. Prostate cancer: 1.5 T endo-coil dynamic contrast-enhanced MRI and MR spectroscopy-correlation with prostate biopsy and prostatectomy histopathological data

    DEFF Research Database (Denmark)

    Chabanova, E.; Balslev, I.; Løgager, Vibeke Berg

    2010-01-01

    PURPOSE: To investigate diagnostic accuracy of detection of prostate cancer by magnetic resonance: to evaluate the performance of T2WI, DCEMRI and CSI and to correlate the results with biopsy and radical prostatectomy histopathological data. MATERIALS AND METHODS: 43 patients, scheduled for radical...... techniques and histopathological findings on prostatectomy specimens. RESULTS: Prostate cancer was identified in all 43 patients by combination of the three MR techniques. The detection of prostate cancer on sextant-basis showed sensitivity and specificity: 50% and 91% for TRUS, 72% and 55% for T2WI, 49......% and 69% for DCEMRI, and 46% and 78% for CSI. CONCLUSION: T2WI, DCEMRI and CSI in combination can identify prostate cancer. Further development of MR technologies for these MR methods is necessary to improve the detection of the prostate cancer...

  8. Human brain mapping of language-related function on 1.5T magnetic resonance system: focused on motor language function

    International Nuclear Information System (INIS)

    Jung, Hee Young; Kim, Jae Hyoung; Shin, Taemin; Piao, Xiang Hao; Kim, Jae Soo; Lee, Gyung Kyu; Park, Il Soon; Park, Ji Hoon; Kang, Su Jin; You, Jin Jong; Chung, Sung Hoon

    1998-01-01

    To investigate the feasibility of functional MR imaging of motor language function and its usefulness in the determination of hemispheric language dominance. In order to activate the motor center of language, six subjects ( 5 right-handed, 1 left-handed: 3 males: 3 females) generated words. They were requested to do this silently, without physical articulation, in response to English letters presented visually. Gradient-echo images (TR/TE/flip angle, 80/60/40 deg; 64 x 128 matrix; 10 mm thickness) were obtained in three axial planes including the inferior frontal gyrus. Functional maps were created by the postprocessing of gradient-echo images, including subtraction and statistics. Areas of activation were topographically analyzed and numbers of activated pixels in each region were compared between right and left sides. The reproducibility of functional maps was tested by repetition of functional imaging in the same subjects. Our results suggest that functional MR imaging can depict the activation of motor language function in the brain and can be used a useful non-invasive method for determining the hemispheric dominance of language. (author). 26 refs., 3 figs

  9. Dynamic double-echo perfusion study of cervix-carcinomas before and after radiation at a 0.5T routine scanner

    International Nuclear Information System (INIS)

    Neumann, U.; Klengel, S.; Kaulen, F.; Schorcht, J.

    1997-01-01

    There is an increasing interest in non-invasive measurement of hemodynamic parameters in tumors. MRI is a valuable method for the evaluation and morphological staging of cervix carcinomas. The sensitivity to radiation should correlate with the pathoanatomical grade of vascularization. We tested the value of perfusion imaging in cervix tumors before and after radiation to optimize therapy. In 38 patients with cervix carcinoma (stage T2-T4) we simultaneously measured dynamic T 1 and T 2 * signal changes after bolus application of the paramagnetic contrast medium Gd-DTPA. We detected 3 patterns of uncorrected simultaneous dynamic T 1 and T 2 * signal changes in cervix tumors, which allows the differentiation of high, reduced and no T 2 * signal loss. Most tumors with a strong perfusion effect showed good regression during and after radiation therapy. More than 60% of cervix carcinomas with low or no perfusion effects were characterized by incomplete tumor reduction. Further study is necessary to prove the statistical significance allowing prospective differentiation of cervix tumors into therapy-responders and non-responders. (orig.)

  10. Value of different MR techniques in diagnosis of degenerative disorders of the hyaline cartilage - in vitro study on 50 joint specimens of the knee with 1.5 T; Vergleich von verschiedenen MRT-Techniken in der Diagnose von degenerativen Knorpelerkrankungen - in-vitro-Studie an 50 Gelenkpraeparaten des Knies bei 1,5 T

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, G. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Heinrichs, C. [Klinikum der Univ. Giessen (Germany). Inst. fuer Pathologie; Juergensen, I. [Klinikum der Univ. Giessen (Germany). Orthopaedische Klinik; Rominger, M. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Scheiter, A. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Rau, W.S. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie

    1997-05-01

    Purpose: An experimental study was performed on joint specimens of the knee to assess the advantages and disadvantages of 14 generally available sequences in cartilage imaging. Methods: Each of the 50 surgically exposed cadaveric joints of the knee was examined by the following sequences: T{sub 1}, proton- and T{sub 2} weighted spin echo(SE) sequences, proton- and T{sub 2} weighted Turbo-SE, T{sub 1} weighted SE with fat suppression, MTC combined with T{sub 1}-weighted SE and T{sub 2} weighted FLASH-2 D, STIR, FISP-3 D, FLASH-3 D (with fat suppression), and MR arthrography. We assessed the image quality by a scale, signal to noise-ratio of cartilage and joint fluid, and the accuracy in detection of cartilage lesions. Pathology and arthroscopy were reference methods to MRI, and demonstrated grade 1-4 lesions on 186 of 300 joint facettes. Results: Advanced stages of cartilage lesions (65 grade 3 and 4 lesions) were detected by standard SE sequences in 67-94%. Application of volume techniques (FISP-3 D, FLASH-3 D), high definition matrix (512 pixel), MTC with FLASH-2 D and MR-arthrography improved the sensitivity up to 82-100%. Superficial lesions (65 grade 2 lesions) were demonstrated in 3-38%, and on MR arthrography in 45%. Structural changes (56 Grade 1 lesions) were recorded on MRI in only 10%. Conclusions: With regard to standard SE sequences, the detectability of cartilage lesions can be improved by techniques that use 512 matrices, selective cartilage imaging, and volume acquisition. (orig.) [Deutsch] Ziel: In einer experimentellen Studie an Gelenkpraeparaten des Knies wurden die Vor- und Nachteile von 14 allgemein verfuegbaren MRT-Sequenzen in der Knorpeldiagnostik dargestellt. Methode: 50 chirurgisch exstirpierte Kniegelenkpraeparate wurden nacheinander mit folgenden Techniken untersucht: Klassische Spin-Echo(SE)-Sequenz in T{sub 1}-, Protonen- und T{sub 2}-Wichtung, Turbo-SE in Protonen- und T{sub 2}-Wichtung, Fettsuppression mit T{sub 1}-gew. SE, MTC in Verbindung mit T{sub 1}-gew. SE und T{sub 2}-gew. FLASH-2D, die STIR, FISP-3 D, FLASH-3 D mit Fettsuppression und die MR-Arthrographie. Fuer jede Sequenz wurden subjektive Qualitaetskriterien, Signal-Rausch-Verhaeltnisse von Knorpel und Gelenkfluessigkeit und Nachweisraten fuer Knorpellaesionen bestimmt. Als Referenz zur MRT dienten pathologische und arthroskopische Untersuchungen, die an 186 der 300 Knorpelflaechen degenerative Veraenderungen Grad 1-4 nachwiesen. Ergebnisse: Die Defektstadien Grad 3 und 4 (65 Laesionen) waren mit den klassischen SE-Sequenzen in 67-94% nachweisbar. Die Volumentechniken (FISP-3 D und FLASH-3 D), Sequenzen mit 512er Matrix, der MTC (mit FLASH-2 D) und die MR-Arthrographie fuehrten zu einer Verbesserung der Sensitivitaet auf 82-100%. Oberflaechliche Defekte Grad 2 (65 Laesionen) hatten Nachweisraten von 3-38%, in der MR-Arthrographie betrug sie 45%. Die rein strukturellen Knorpelveraenderungen Grad 1 (56 Faelle) wurden in ca. 10% diagnostiziert. Schlussfolgerung: Die Diagnostik von Knorpelerkrankungen laesst sich gegenueber den klassischen SE-Sequenzen mit grosser Bildmatrix, verbessertem Knorpelkontrast und Volumentechnik verwenden. (orig.)

  11. 78 FR 30367 - Self-Regulatory Organizations; BOX Options Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-05-22

    ... product by keeping the Jumbo SPY Options fees low and easy for investors to understand. The Exchange... charge the same rate for transactions in Jumbo SPY Options, since the costs to the Exchange to process... charge the ORF at the same rate as the standard contract. 2. Statutory Basis The Exchange believes that...

  12. 78 FR 40101 - Certain Tissue Paper Products from the People's Republic of China: Affirmative Final...

    Science.gov (United States)

    2013-07-03

    ... subject to the order are cut-to-length sheets of tissue paper having a basis weight not exceeding 29 grams... determine that tissue paper processed by ARPP in India from PRC-origin jumbo rolls and/or cut sheets of...-origin tissue paper (jumbo rolls and/or cut sheets) that were entered, or withdrawn from warehouse, for...

  13. MASIH RELEVANKAH STRATEGI MARKETING MIX MENINGKATKAN KEPUASAN PELANGGAN

    Directory of Open Access Journals (Sweden)

    Tondano (Jalan kampus UNIMA, Manado, In Juliana Ohy

    2010-09-01

    Full Text Available Penelitian ini bertujuan menganalisis pengaruh marketing mix strategy terhadap kepuasan pelanggan Pasar Swalayan Jumbo di Manado. Sampel diambil secara acak sebanyak 100 pelanggan dengan metode pengumpulan data berupa kuesioner dan studi dokumen. Selanjutnya, data dianalisis menggunakan path analysis. Hasil penelitian menunjukkkan bahwa keseluruhan unsur-unsur marketing mix yaitu produk, harga, tempat/lokasi dan promosi secara simultan maupun secara parsial berpengaruh signifikan terhadap kepuasan pelanggan pasar swalayan Jumbo di Manado. Implikasi manajerialnya adalah bauran pemasaran yang dilakukan oleh pasar swalayan Jumbo penting untuk ditingkatkan dan dimantapkan perannya untuk mengurangi gap antara harapan dan kinerja pasar swalayan Jumbo. Swalayan Jumbo perlu melakukan perbaikan agar dapat meningkatkan kepuasan pelanggan yang pada akhirnya dapat meningkatkan hasil penjualan. Perbaikan yang dapat dilakukan antara lain dengan melaksanakan Retensi Pelanggan- berupa loyality program, yang terbukti secara signifikan mampu meningkatkan retensi pelanggan dan jumlah pembelian. This study aims to analyze the influence of marketing mix strategy toward customer satisfaction of Jumbo Supermarket in Manado. Samples were taken randomly from 100 customers. Meanwhile, questionnaire and study of documents are the method that is used to collect the data. Furthermore, the data were analyzed using path analysis. The results indicate that the overall marketing mix’s elements which are consist of product, price, place and promotion, simultaneously and partially has a significant effect toward customer satisfaction of Jumbo Supermarket in Manado. In addition, managerial implications of marketing mix which is made by Jumbo supermarket is important to be improved and to be strengthened in its role to reduce the gap between expectations and performance of the Jumbo Supermarket. The improvements of customer satisfaction is also necessary to increase sales

  14. CCDC 969738: Experimental Crystal Structure Determination : catena-(hexakis(mu4-5-t-Butylisophthalato)-hexakis(mu3-isonicotinato)-(mu3-oxo)-diaqua-hydroxy-tri-chromium-hexa-zinc dimethylformamide solvate)

    KAUST Repository

    Schoedel, Alexander; Boyette, Wesley; Wojtas, Lukasz; Eddaoudi, Mohamed; Zaworotko, Michael J.

    2013-01-01

    An entry from the Cambridge Structural Database, the world’s repository for small molecule crystal structures. The entry contains experimental data from a crystal diffraction study. The deposited dataset for this entry is freely available from the CCDC and typically includes 3D coordinates, cell parameters, space group, experimental conditions and quality measures.

  15. CCDC 1024818: Experimental Crystal Structure Determination : 5-(((t-Butyl(dimethyl)silyl)oxy)(diphenyl)methyl)-2-phenyl-2,5,6,7-tetrahydro-3H-pyrrolo[2,1-c][1,2,4]triazole-3-selenone

    KAUST Repository

    Vummaleti, Sai V. C.; Nelson, David J.; Poater, Albert; Gó mez-Suá rez, Adriá n; Cordes, David B.; Slawin, Alexandra M. Z.; Nolan, Steven P.; Cavallo, Luigi

    2015-01-01

    An entry from the Cambridge Structural Database, the world’s repository for small molecule crystal structures. The entry contains experimental data from a crystal diffraction study. The deposited dataset for this entry is freely available from the CCDC and typically includes 3D coordinates, cell parameters, space group, experimental conditions and quality measures.

  16. CCDC 1441885: Experimental Crystal Structure Determination : 5-t-butyl-2-(14-(4-t-butyl-2,6-diformylphenyl)-5,12-dimethyldibenzo[c,pqr]tetraphen-7-yl)isophthalaldehyde chloroform solvate

    KAUST Repository

    Zeng, Wangdong; Sun, Zhe; Herng, Tun Seng; Goncalves, Theo; Gopalakrishna, Tullimilli Y.; Huang, Kuo-Wei; Ding, Jun; Wu, Jishan

    2016-01-01

    An entry from the Cambridge Structural Database, the world’s repository for small molecule crystal structures. The entry contains experimental data from a crystal diffraction study. The deposited dataset for this entry is freely available from the CCDC and typically includes 3D coordinates, cell parameters, space group, experimental conditions and quality measures.

  17. Endothelial cell-driven regulation of CD9 or motility-related protein-1 expression in multiple myeloma cells within the murine 5T33MM model and myeloma patients

    DEFF Research Database (Denmark)

    De Bruyne, E; Levin Andersen, Thomas; De Raeve, H

    2006-01-01

    The cell surface expression of CD9, a glycoprotein of the tetraspanin family influencing several processes including cell motility and metastasis, inversely correlates with progression in several solid tumors. In the present work, we studied the expression and role of CD9 in multiple myeloma (MM...... interaction of the cells with BMEC and that CD9 is involved in transendothelial invasion, thus possibly mediating homing and/or spreading of the MM cells....

  18. CCDC 1441886: Experimental Crystal Structure Determination : (5,12-dimethyldibenzo[c,pqr]tetraphene-7,14-diyl)bis((5-t-butylbenzene-2,1,3-triyl)bis(methylene)) tetraacetate

    KAUST Repository

    Zeng, Wangdong; Sun, Zhe; Herng, Tun Seng; Goncalves, Theo; Gopalakrishna, Tullimilli Y.; Huang, Kuo-Wei; Ding, Jun; Wu, Jishan

    2016-01-01

    An entry from the Cambridge Structural Database, the world’s repository for small molecule crystal structures. The entry contains experimental data from a crystal diffraction study. The deposited dataset for this entry is freely available from the CCDC and typically includes 3D coordinates, cell parameters, space group, experimental conditions and quality measures.

  19. Elastic scattering of charged mesons, antiprotons and protons on protons at incident momenta of 20, 30 and 50 GeV/c in the momentum tranfer range 0. 5 <= -t < 8 (GeV/c)/sup 2/

    Energy Technology Data Exchange (ETDEWEB)

    Asa' d, Z.; Coupland, M.; Davis, D.G.; Duff, B.G.; Fearnley, T.; Heymann, F.F.; Imrie, D.C.; Lush, G.J.; Phillips, M. (University Coll., London (UK)); Baglin, C.

    1985-06-24

    Results are presented from experiment WA7 at the CERN SPS, which has measured the elastic differential cross sections of ..pi..sup(+-)p, Ksup(+-)p, anti pp and pp at incident momenta of 20, 30 and 50 GeV/c. The measurements cover the momentum transfer range 0.5 < vertical stroketvertical stroke < 8 (GeV/c)/sup 2/, corresponding to c.m. scattering angles between 10/sup 0/ and 50/sup 0/. The experimental set-up, trigger logic and data analysis are described. The experimental results are compared with existing meson-proton and nucleon-proton data at lower and higher energies covering the medium- and large-vertical stroketvertical stroke region. Some prominent models and their predictions for elastic scattering at WA7 energies and beyond are reviewed, with emphasis on geometrical scaling, factorizing eikonal models, lowest-order QCD and other dynamical exchange-type models. Results for anti pp two-body annihilation into ..pi../sup -/..pi../sup +/ and K/sup -/K/sup +/ at 30 and 50 GeV/c, obtained in parallel with the elastic anti pp data, are also presented.

  20. Clinical outcomes of brain metastases treated with gamma knife radiosurgery with 3.0 T versus 1.5 T MRI-based treatment planning: have we finally optimised detection of occult brain metastases?

    International Nuclear Information System (INIS)

    Loganathan, Amritraj G.; Alphonse, Natalie; Chan, Michael D.

    2012-01-01

    The goal of this study was to determine if clinically relevant endpoints were changed by improved MRI resolution during radiosurgical treatment planning. Between 2003 and 2008, 200 consecutive patients with brain metastases treated with Gamma Knife radiosurgery (GKRS) using either 1.5 T or 3.0 T MRI for radiosurgical treatment planning were retrospectively analysed. The number of previously undetected metastases at time of radiosurgery, distant brain failures, time delay to whole brain radiotherapy (WBRT), overall survival and likelihood of neurological death were determined. Additional metastases were detected in 31.3% and 24.5% of patients at time of radiosurgery with 3.0 T and 1.5 T MRI, respectively (P = 0.27). Patients with multiple metastases at diagnostic scan were more likely to have additional metastases detected by 3.0 T MRI (P < 0.1). Median time to distant brain failure was 4.87 months and 5.43 months for the 3.0 T and 1.5 T cohorts, respectively (P = 0.44). Median time to WBRT was 5.8 months and 5.3 months for the 3.0 T and 1.5 T cohorts, respectively (P = 0.87). Median survival was 6.4 months for the 3.0 T cohort, and 6.1 months for the 1.5 T cohort (P = 0.71). Likelihood of neurological death was 25.3% and 16.7% for the 3.0 and 1.5 T populations, respectively (P = 0.26). The 3.0 T MRI-based treatment planning for GKRS did not appear to affect the likelihood of distant brain failure, the need for WBRT or the likelihood of neurological death in this series.

  1. Port Harcourt Medical Journal - Vol 9, No 1 (2015)

    African Journals Online (AJOL)

    How much do diabetic patients know about self monitoring of their blood sugar? EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. TE Ambakederemo, J Jumbo, ST Dodiyi Manuel, 33-38 ...

  2. Investigations into a potential laser-NASP transport technology

    Science.gov (United States)

    1990-01-01

    Laser propelled flight/transport technology is surveyed. A detailed conceptual design is presented for an on-place Mercury-Lightcraft: other designs are briefly explored for larger, 15-place Executive Lightcraft, and 150 to 350 passenger Jumbo Lightcraft.

  3. CO{sub 2}-effective protection against scaling in solar installations. Physical scale protection: mumbo-jumbo or reality? Experience gained in a research project; CO{sub 2}-Effizienter Kalkschutz bei Solaranlagen. Physikalischer Kalkschutz: Hokuspokus oder Realitaet? Erfahrungen aus einem Forschungsprojekt

    Energy Technology Data Exchange (ETDEWEB)

    Frei, U.

    2000-07-01

    This paper takes a look at two methods used to prevent the scaling-up of flat-plate heat-exchangers often used in large solar installations. The mechanisms involved in the development of 'hardness' in water and the precipitation of scale are described and the problems caused by the latter are discussed. The first method for fighting scale discussed is the controlled addition of carbon dioxide to the water passing through the heat-exchanger. An example of the use of this method in a solar plant with 94 m{sup 2} of vacuum collectors and 17,000 litres of storage is given. The second method of reducing scaling discussed is the treatment of the water with electromagnetic fields. The various types of units available (permanent magnets, electrodes, AC-driven apparatus) are briefly described and compared. Work done and the results obtained in a research project using an AC-based system are described in detail.

  4. 个体生长对秘鲁外海茎柔鱼角质颚形态变化的影响%Effect of individual growth on beak morphometry of jumbo flying squid, Dosidicus gigas off the Peruvian Exclusive Economic Zone

    Institute of Scientific and Technical Information of China (English)

    胡贯宇; 陈新军; 方舟

    2016-01-01

    为研究个体生长对茎柔鱼角质颚形态变化的影响,本研究根据2009-2014年中国鱿钓船在秘鲁外海(79°22′~84°30′W、10°00′~18°16′S)采集的茎柔鱼样本,提取出1208尾茎柔鱼的角质颚,对角质颚的12项外部形态进行测量,并利用角质颚微结构的生长纹来估算茎柔鱼的日龄,采用方差分析法(ANOVA)分析了不同胴长组、不同日龄组以及不同性成熟阶段角质颚主要外部形态特征的差异.结果表明,角质颚各形态参数在雌、雄个体间的差异性极显著(P<0.01),且雌性个体的角质颚大于雄性个体.最小显著差多重比较法(LSD)结果显示,在不同胴长组、不同日龄组和不同性成熟阶段,雌、雄个体角质颚的生长存在差异,相同性别个体角质颚不同部位的生长也不同;在胴长大于400 mm、雌性个体大于300日龄、雄性个体大于250日龄以及性腺成熟度在Ⅲ期以后时,角质颚的生长较为缓慢.研究表明,个体大小、日龄和性成熟对茎柔鱼角质颚的形态变化有一定的影响.

  5. Maximaal 500 verkeersdoden in 2020: waarom eigenlijk niet? : maatregelpakketten en effectschattingen om te komen tot een aangescherpte verkeersveiligheidsdoelstelling.

    NARCIS (Netherlands)

    Aarts, L.T. Weijermars, W.A.M. Schoon, C.C. & Wesemann, P.

    2008-01-01

    Annually, Dutch road traffic counts approximately 800 fatalities. Each year, that amounts to one-and-a-half jumbo jet full of people that will not return home any more. In the drawing up of a new Road Safety Plan 2008-2020 by the Ministry of Transport, Public Works and Water Management, the question

  6. 76 FR 47551 - Certain Tissue Paper Products From the People's Republic of China: Affirmative Final...

    Science.gov (United States)

    2011-08-05

    ... accounting law,\\10\\ but did not do so.\\11\\ Despite its claims, MFVN could not conclusively demonstrate that... Accounting Law, Applicable to Business Activities,'' issued by the Government of the Socialist Republic of... the requested production and accounting records to show when it ceased using Chinese-origin jumbo...

  7. Adaptation of eight American blackberry ( Rubus fructicosus L ...

    African Journals Online (AJOL)

    evaluate the performance of Arapaho, Black Satin, Cherokee, Chester Thornless, Dirksen Thornless, Jumbo, Navaho and Loch Ness cultivars of American origin for adaptation under Central Anatolian conditions at Ankara during 2002 - 06. The results showed that changes in the environmental conditions affected yield, ...

  8. Genetic diversity among some blackberry cultivars and their ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-05

    Oct 5, 2009 ... Bursa 3, Chester, Dirckson Thornless, Jumbo, Navaho and Loch. Ness) and a Boysenberry clone were included in this study for. AFLP analysis. While eight of these are known cultivars from North. America, remaining three, Bursa 1, Bursa 2 and Bursa 3, are the blackberry genotypes with unknown origin.

  9. Browse Title Index

    African Journals Online (AJOL)

    Items 1 - 50 of 50 ... Vol 1, No 2 (2014), Growing Up With Prune Belly Syndrome In A Resource Poor Setting, Abstract. Assumpta Udechi Chapp-Jumbo, Benson Nnamdi Onyire, Ngozi Ulonnam, Enobong Ikpeme. Vol 4, No 1 (2017), Imaging in Urinary Tract Infectioin, Abstract. ZM Jawa, O Oniyangi, UN Ononiwu. Vol 4, No 1 ...

  10. 78 FR 7835 - Self-Regulatory Organizations; BOX Options Exchange LLC; Notice of Filing of Proposed Rule Change...

    Science.gov (United States)

    2013-02-04

    ... respect to the related arbitrage, the Exchange understands that the OCC's portfolio margining process will... to result in more efficient pricing through arbitrage with standard contracts. Additionally, the... believes Jumbo SPY options will provide investors with an additional tool for hedging risk in the highly...

  11. Abia State University Medical Students' Association Journal - Vol 9 ...

    African Journals Online (AJOL)

    Antisocial Personality disorder · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. O Chinasa. Breaking the intergenerational transmission of poverty through good nutrition · EMAIL FULL TEXT EMAIL FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. A Chapp-Jumbo ...

  12. Nuptial poetry among the Tiv of Nigeria

    African Journals Online (AJOL)

    Tiv origin, the version that commands popularity and currency is that which traces their origin to the .... (1939: 38) was usually done by some “scoundrel[s]” who could fall on a travelling couple and take .... made up the nuptial musical ensemble: the indyer or ilyu (jumbo or medium-size) ... To rise and greet Ayua Yeke. Let the ...

  13. 78 FR 14514 - Certain Tissue Paper Products From the People's Republic of China: Affirmative Preliminary...

    Science.gov (United States)

    2013-03-06

    ... Antidumping Duty Order The tissue paper products subject to this order are cut-to-length sheets of tissue... are produced in India from PRC-origin jumbo rolls and/or cut sheets of tissue paper, and exported from... DEPARTMENT OF COMMERCE International Trade Administration [A-570-894] Certain Tissue Paper...

  14. Automation of strata bolting in iron mines

    Energy Technology Data Exchange (ETDEWEB)

    Belin, M; Lethuaire, M

    1978-01-01

    The Moyeure iron mine (Lorraine), with an output of 16,000 t/day, works 2 seams separated by a dirt band 6.50 m thick. The tyre-mounted Diesel Secoma jumbo for bolting operations can insert resin-embedded bolts 1.70 m in length. The jumbo is fitted with a standard universal boom with two settings - one for drilling and one for bolting. As the operator has to work in the unbolted zone in order to offer up the bolt on the boom and insert the resin cartridge, the mine in conjunction with the manufacturers, Secoma, have improved the safety and performance of the machine by adding three special attachments to the standard boom: a reamer, a resin-injection system and a bolt supply-magazine. Gives details of the results achieved. (In French)

  15. The central part of CMS is lowered

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    On 28 February 2007, the CMS central piece containing the magnet and weighing as much as five Jumbo jets (1920 tonnes) was gently lowered into place. Only 20 cm separated the detector, which was suspended by four huge cables, each with 55 strands and sophisticated monitoring to minimize sway and tilt, from the walls of the shaft. The entire process took about 10 hours to complete.

  16. Nuclear power: Hour of fog producers

    International Nuclear Information System (INIS)

    Rauner, M.; Schuh, H.

    2004-01-01

    Seven advanced nuclear power plants in Germany can withstand a frontal crash by a full-tanked Jumbo-Jet. But for five older plants even smaller planes can cause an hazard impossible to control. A fog generation around the power plants, favorized by operators and politicians, to camouflage this plants against terroristic flights is absurd because of the possibility of flight automation. However terrorists may attack reactors also from the ground, but how they can do is top secret. (GL) [de

  17. Research Evaluation Management Services for The Chemistry and Life Sciences Program

    Science.gov (United States)

    2005-11-30

    Soup, Smoked Salmon, Pomegranate Granita, Roast Colorado Lamb, Chocolate Crepe al Orange Session A3 Prof. Rudy Buchheit, Session Chair 7:00-7:40...Open 5:30-7:00 Dinner - Jumbo Shrimp Cocktail, Five Onion Soup, Passion Fruit Sorbet, Tenderloin of Beef and Spice Rubbed Salmon, Kiwi Wild Berry Mille...D. A. Shifler Naval Surface Warfare Center, West Bethesda, MD 1600 Effect of Orientation on Fatigue Crack Initiation from Corrosion Damage M. Khobaib1

  18. Managing Fatigue in Long Duration Airlift Operations 1994

    Science.gov (United States)

    2001-03-01

    Air Force Research Laboratory Brooks Air Force Base, Texas, USA Abstract During September, 1994 the operational tempo for US Air Force C-5 transport...Nandina Terrace, Winter Springs, Fl 32708, USA Paper presented at the RTO HFM Workshop on "The Effect of Prolonged Military Activities in Man...drink. They were drinking lots of coffee and beer and most were eating a gastronomically difficult creation called a jumbo burger. We were given 24 hours

  19. Robotics for mining control

    Energy Technology Data Exchange (ETDEWEB)

    1986-11-01

    In 1982 surveys of the mining industry revealed no applications of robotics existed and none were planned. This report provides a general overview of automation in the mining industry since this point in time. Roof control electronics, gas monitoring, jumbo drill automation, remote and sensor- controlled continuous miners, automated trolley trucks, roof bolting and screening machines are examples of technology available today. The report concludes with recommendations as to six potential research areas. 25 refs.

  20. Growth evaluation of Lentinula edodes in solid medium cultures for mycelium production as inoculum

    OpenAIRE

    Villegas E Valeska; Pérez Ana Milena; Arredondo Clara

    2007-01-01

    Shitake (Lentinula edodes) Pegler jumbo strain growth was evaluated in different solid mediums and growth substrates for spawn production. Mycelium growth was tested in three culture mediums (MYA, OMYA, PDYA) at two pHs (5, 5.5), using two eucalyptus sawdust percentages (0.3%, 0.2%). Analysing variance revealed significant differences in culture medium (P0.05). The liquid inoculation technique was used for evaluating mushroom spawn production using five different combinations of eucalyptus sa...

  1. Intra-Operational Area Coordination: The Zone EOC Concept

    Science.gov (United States)

    2015-09-01

    200, operating as Asiana Airlines flight 214 , was on approach to runway 28L when it struck a seawall at San Francisco International Airport (SFIA...training and lacked the necessary training and experience to land a jumbo jet onto an airstrip with a sea wall. The Asiana Airline incident also...Crash of Asiana Flight 214 Accident Report Summary, 2014, accessed August 31, 2015, http://www.ntsb.gov/news/events/Pages/ 2014_Asiana_BMG

  2. Informed and Uninformed Investment in Housing: The Downside of Diversification

    OpenAIRE

    Elena Loutskina; Philip E. Strahan

    2011-01-01

    Mortgage lenders that concentrate in a few markets invest more in information collection than diversified lenders. Concentrated lenders focus on the information-intensive jumbo market and on high-risk borrowers. They are better positioned to price risks and, thus, ration credit less. Adverse selection, however, leads to higher retention of mortgages relative to diversified lenders. Finally, concentrated lenders have higher profits than diversified lenders, their profits vary less systematical...

  3. Power marketing

    International Nuclear Information System (INIS)

    Sioshansi, F.P.; Altman, A.M.

    1998-01-01

    One of the most significant developments in the US electric power industry in recent years has been the phenomenal growth of power marketing. What was barely a blimp on the radar screen in 1992 has turned out to be a jumbo jet. This article explains what is power marketing who are power marketers, what role play these players and what will be their longer-term impact on the traditional industry [it

  4. MELHORAMENTO DO TOMATEIRO: II. PROCEDIMENTO DE GARDNER E EBERHART NA ANÁLISE HETERÓTICA DE CARACTERÍSTICAS MORFOAGRONÔMICAS E DA QUALIDADE DOS FRUTOS

    Directory of Open Access Journals (Sweden)

    AMARAL JÚNIOR ANTÔNIO TEIXEIRA DO

    1997-01-01

    Full Text Available Cinco cultivares de tomateiro (Lycopersicon esculentum Mill. - Ângela I.5100, Floradade, IPA-05, Jumbo AG-592 e Santa Clara - e seus p (p - 1/2 cruzamentos foram avaliados quanto a dez características morfoagronômicas e cinco relacionadas à qualidade dos frutos, pelo método de Gardner e Eberhart. Os resultados evidenciaram suficiente variabilidade entre os parentais para a maioria das características, indicando uma situação favorável à aplicação do melhoramento genético. A potencialização das características `teor de carotenóides totais' e `conteúdo de beta-caroteno' nos frutos poderá ser alcançada por meio dos intercruzamentos envolvendo os cultivares Ângela I.5100, Floradade e Jumbo AG-592, enquanto apenas a combinação Jumbo AG-592 x Ângela I.5100 revelou possibilidade de incrementos nos teores de vitamina C. Considerando-se conjuntamente as características morfoagronômicas e as relacionadas à qualidade dos frutos, conclui-se que os cultivares Ângela I.5100, Floradade e Santa Clara são os de maior potencial para compor intercruzamentos.

  5. Book of Abstracts, Logic Colloquium 󈨦, the ASL European Summer Meeting, August 9-15, 1998, Prague, Czech Republic.

    Science.gov (United States)

    1998-09-23

    the First Hypothesis of Plato’s Parmenides and the Undecidable Sentence of Kurt Godel 155 D. Drai Concepts of validity 156 M. L Zelbert, Logical...account of mathematics in the "Tractatus". -154- LC 󈨦 Book of Abstracts A Comparison Between the First Hypothesis of Plato’s Parmenides and the...42)(05)43129386 svandova@jumbo.ped.muni.cz in the second half of the twentieth century there has been a revival of interest in Plato’s Parmenides

  6. Relativity a very short introduction

    CERN Document Server

    Stannard, F Russell

    2008-01-01

    Relativity: A Very Short Introduction makes the theory of relativity understandable and accessible. 100 years ago, Einstein's theory of relativity shattered the world of physics. Our comforting Newtonian ideas of space and time were replaced by bizarre and counterintuitive conclusions: if you move at high speed, time slows down, space squashes up and you get heavier; travel fast enough and you could weigh as much as a jumbo jet, be squashed thinner than a CD without feeling a thing - and live forever. And that was just the special theory. With the general theory came even stranger ideas of curved space-time, which changed our understanding of gravity and the cosmos.

  7. ZUNANJE OGLAŠEVANJ NA PRIMERU BLAGOVNE ZNAMKE COCA-COLA

    OpenAIRE

    Justinek, Vanesa

    2016-01-01

    V diplomskem seminarju z naslovom Zunanje oglaševanje na primeru blagovne znamke Coca Cola govorim predvsem o oglasih, ki so izven zaprtih prostorov. Zunanje oglaševanje je oblika tržnega komuniciranja ter plačana oblika oglaševanja, poteka preko sredstev javnega obveščanja. V to obliko oglaševanja sodijo: Veleplakati (jumbo plakati), mali panoji (city panoji), digitalni panoji, polepitve na prevoznih sredstvih, oglasni stebri, transparenti nad voziščem, obešanke, oglasni stolpi. V prvem t...

  8. Update on VUV and soft X-ray facilities at SSRL

    International Nuclear Information System (INIS)

    Waldhauer, A.

    1988-01-01

    The number of experimental stations at SSRL devoted to the VUV and soft X-ray region is increasing rapidly. In 1986 there were five VUV/soft X-ray beam lines in regular operation. These consisted of two grasshopper lines, a Seya-Namioka line, a white light lithography line, and the UHV double crystal line, Jumbo. By 1988 ten beam lines, including two with insertion devices, covering the spectral range 5-4000 eV in five overlapping ranges will be operational. With the addition of these new stations, SSRL will have increased dramatically its facilities for performing VUV and soft X-ray research. (orig.)

  9. Feeding of blue marlin Makaira nigricans off Mazatlan, Sinaloa, Mexico Alimentación del marlin azul Makaira nigricans del área de Mazatlán, Sinaloa, México

    OpenAIRE

    Leonardo Abitia-Cárdenas; Dana Arizmendi-Rodríguez; Napoleón Gudiño-González; Felipe Galván-Magaña

    2010-01-01

    We analyzed the stomach contents of 52 blue marlins caught between October 2002 and October 2004 by the sport-fishing fleet of Mazatlan, Sinaloa, in the gulf of California, Mexico. Blue marlin feed on 15 food items. According to the index of relative importance (IRI), the most important prey were the frigate or bullet mackerel Auxis spp. (52%) and jumbo squid Dosidicus gigas (30%).Se analiza el contenido estomacal de 52 marlines azules capturados por la flota de pesca deportiva que operó en e...

  10. Deception and the Mediterranean Campaigns of 1943-1944

    Science.gov (United States)

    1986-03-31

    South East Asia Command; Fleming by the way, • was the brother of Ian I’leming, the British spy novelist. Regardless of these evolutions in the...British. 7. David Mure, MAsJl . "rpn., D IAn &led Webk in - an the Kiddla Ka"e. p. 131. ’ 8. Interviews with Mure. The role of Noel Wild in "A" Force...Supreme Allied Commander, Mediterranean) .’- 175 General Maitland "Jumbo" Wilson to conduct operations against 7 southern France at about the same

  11. Operation STRANGLE (Italy, Spring 1944): A Case Study of Tactical Air Interdiction

    Science.gov (United States)

    1972-02-01

    units. General Eaker reported to the new theater coi11Tlander, General Sir Henry Maitland ("Jumbo") Wilson, who had replaced General Eisenhower as...in Italy. The idea of using airpower on a massive scale to smash the German resistance on the I tal ian front was not new. It had been urged by...Brigadier W.G.F. Jackson, then on General Alexander’s staff, re- counts: "Moreover, he [General Alexander] was just as keen as Maitland Wilson [SACMED] to

  12. The-GEOSCOPE Program

    Directory of Open Access Journals (Sweden)

    J. P. Montagner

    1994-06-01

    Full Text Available he purpose of the GEOSCOPE Program was the installation of 25 stations in the standard configuration defined by the FDSN (VBB 24 bit, continuous recording at 20 samples/s. The installation is almost complete. The effort this year focussed on the accessibility of data, either through the IRIS/GOPHER system for large earthquakes, through CD-ROM production, and on line using the Juke-box JUMBO in the GEOSCOPE Data Center (Paris. This aspect will be stressed as the cooperation between IRIS and GEOSCOPE intensifies.

  13. Modelling and designing electric energy networks

    International Nuclear Information System (INIS)

    Retiere, N.

    2003-11-01

    The author gives an overview of his research works in the field of electric network modelling. After a brief overview of technological evolutions from the telegraph to the all-electric fly-by-wire aircraft, he reports and describes various works dealing with a simplified modelling of electric systems and with fractal simulation. Then, he outlines the challenges for the design of electric networks, proposes a design process, gives an overview of various design models, methods and tools, and reports an application in the design of electric networks for future jumbo jets

  14. Growth evaluation of Lentinula edodes in solid medium cultures for mycelium production as inoculum

    Directory of Open Access Journals (Sweden)

    Valeska Villegas E

    2007-07-01

    Full Text Available Shitake (Lentinula edodes Pegler jumbo strain growth was evaluated in different solid mediums and growth substrates for spawn production. Mycelium growth was tested in three culture mediums (MYA, OMYA, PDYA at two pHs (5, 5.5, using two eucalyptus sawdust percentages (0.3%, 0.2%. Analysing variance revealed significant differences in culture medium (P0.05. The liquid inoculation technique was used for evaluating mushroom spawn production using five different combinations of eucalyptus sawdust and wheat grain, finding significant differences between treatments, the best combination for shiitake growth being 80% wheat grain and 20% eucalyptus sawdust.

  15. Diamond-set drill bits: savings achieved at Cominak

    International Nuclear Information System (INIS)

    Artru, P.; Bibert, F.X.; Croisat, G.

    1988-01-01

    Rotary instead of percussion adoption of drilling in the underground Akouta mine (Niger) has been the cause of important savings in blasting and bolting operations. Other savings affect capital expenditures and indirect savings are coming from better working conditions. For blast holes drilling and bolting, spare parts expenditures are 2.4 times lower with rotary drilling. Drilling rods are cheaper and last longer with rotary drilling. A rotary equipped Jumbos fleet is cheaper to maintain and is 18% more available, due to less mechanical and other breakdowns. Total savings for the mine owner and operator Cominak reach more than a billion of CFA francs [fr

  16. An Application-Based Performance Evaluation of NASAs Nebula Cloud Computing Platform

    Science.gov (United States)

    Saini, Subhash; Heistand, Steve; Jin, Haoqiang; Chang, Johnny; Hood, Robert T.; Mehrotra, Piyush; Biswas, Rupak

    2012-01-01

    The high performance computing (HPC) community has shown tremendous interest in exploring cloud computing as it promises high potential. In this paper, we examine the feasibility, performance, and scalability of production quality scientific and engineering applications of interest to NASA on NASA's cloud computing platform, called Nebula, hosted at Ames Research Center. This work represents the comprehensive evaluation of Nebula using NUTTCP, HPCC, NPB, I/O, and MPI function benchmarks as well as four applications representative of the NASA HPC workload. Specifically, we compare Nebula performance on some of these benchmarks and applications to that of NASA s Pleiades supercomputer, a traditional HPC system. We also investigate the impact of virtIO and jumbo frames on interconnect performance. Overall results indicate that on Nebula (i) virtIO and jumbo frames improve network bandwidth by a factor of 5x, (ii) there is a significant virtualization layer overhead of about 10% to 25%, (iii) write performance is lower by a factor of 25x, (iv) latency for short MPI messages is very high, and (v) overall performance is 15% to 48% lower than that on Pleiades for NASA HPC applications. We also comment on the usability of the cloud platform.

  17. Electric personnel carrier introduced : RES Equipment Sales spearheads development of electric underground vehicle

    International Nuclear Information System (INIS)

    Tollinsky, N.

    2010-01-01

    RES Equipment Sales of Dryden, Ontario is leading the development of a battery-powered personnel utility vehicle for underground mining applications. Among the advantages of the battery-powered personnel carrier are quietness of the carrier and zero emissions, which eliminates particulates from diesel engines and reduces the need for ventilation. This article discussed the design and building of the vehicle. It was designed to accommodate up to 3 battery packs, depending on the frequency of use. Swapping batteries takes between 2 or 3 minutes. Spent batteries must be plugged in for 6 hours and rest for another 6 to 8 hours before being ready for service. The vehicle accommodates 2 or 3 people and travels at speeds of 6 to 8 miles per hour. This article also provided background information on RES Equipment Sales. The company remanufactures underground mining equipment, including load-haul-dump machines, jumbos, haul trucks and utility vehicles. In addition, the company sells and services new equipment, including Oldenburg Cannon jumbos, scalers and utility vehicles, as well as Canun International pneumatic rock drills and NPK rock breakers. 1 ref., 1 fig.

  18. Isolation of Ralstonia solanacearum-infecting bacteriophages from tomato fields in Chiang Mai, Thailand, and their experimental use as biocontrol agents.

    Science.gov (United States)

    Bhunchoth, A; Phironrit, N; Leksomboon, C; Chatchawankanphanich, O; Kotera, S; Narulita, E; Kawasaki, T; Fujie, M; Yamada, T

    2015-04-01

    To isolate and characterize novel bacteriophages infecting the phytopathogen, Ralstonia solanacearum, and to evaluate them as resources with potential uses in the biocontrol of bacterial wilt. Fourteen phages infecting R. solanacearum were isolated from soil samples collected in Chiang Mai, Thailand. The phages showed different host ranges when tested against 59 R. solanacearum strains isolated from Thailand and Japan. These phages were characterized as nine podoviruses and five myoviruses based on their morphology. Podovirus J2 in combination with another podovirus (φRSB2) lysed host cells very efficiently in contaminated soil. J2 treatment prevented wilting of tomato plants infected with a highly virulent R. solanacearum strain. Treatment with J2 effectively reduced the amount of the bacterial wilt pathogen in contaminated soil and prevented bacterial wilt of tomato in pot experiments. Myovirus J6 possessed jumbo phage features, giving a unique opportunity to study its utilization as a biocontrol agent. As exemplified by J2, the phages isolated in this study represent valuable resources with potential uses in biocontrol of bacterial wilt. A rare jumbo phage J6 served as a valuable subject to understand and utilize this new group of phages. © 2015 The Society for Applied Microbiology.

  19. Nuclear power: Hour of fog producers; Atomkraft: Stunde der Nebelwerfer

    Energy Technology Data Exchange (ETDEWEB)

    Rauner, M.; Schuh, H.

    2004-03-04

    Seven advanced nuclear power plants in Germany can withstand a frontal crash by a full-tanked Jumbo-Jet. But for five older plants even smaller planes can cause an hazard impossible to control. A fog generation around the power plants, favorized by operators and politicians, to camouflage this plants against terroristic flights is absurd because of the possibility of flight automation. However terrorists may attack reactors also from the ground, but how they can do is top secret. (GL) [German] Einem frontalen Aufprall eines voll getankten Jumbo-Jets mit hoher Geschwindigkeit koennen in Deutschland sieben moderne Kernkraftwerke standhalten. Bei fuenf aelteren Modellen kann dagegen selbst ein kleineres Flugzeug ein schwer beherrschbares Unglueck ausloesen. Obwohl Experten eine vorzeitige Schliessung solch alter Meiler fuer realistisch halten, ist die Verhandlungslage aufgrund ideologischer Einfluesse verfahren. Die von Betreibern und Politikern gern gepriesenen Nebelwerfer zur Tarnung der Kraftwerke sind wegen der Moeglichkeit des Instrumentenfluges sinnlos. Die beste Abwehr bieten vorgelagerte Schutzbauten aus Beton. Jedoch koennen Terroristen Reaktoren auch vom Boden aus gefaehrden, wie, ist natuerlich geheim.

  20. Cleanup Summary Report for the Defense Threat Reduction Agency Fiscal Year 2007, Task 6.7, U12u-Tunnel (Legacy Site), Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    2008-01-01

    This letter serves as notice of completion for cleanup of the U12u-Tunnel (Legacy Site) as specified in the Defense Threat Reduction Agency (DTRA) Fiscal Year 2007 Statement of Work, Task 6.7. The U12u-Tunnel Legacy Site is located near the intersection of the U12u-Tunnel access road and the U12n-Tunnel access road in Area 12 of the Nevada Test Site (see Figure 1). The site encompasses 1.2 acres and was used to store miscellaneous mining equipment and materials that were used to support DTRA testing in Area 12. Field activities commenced February 11, 2008, and were completed February 20, 2008. Radiological surveys were performed on a drill jumbo and all material stored at the site. The drill jumbo was relocated to U12p-Tunnel portal and consolidated with other critical mining equipment for future use or storage. Ten truck loads of solid waste (53 tons) were shipped to the Nevada Test Site, Area 9 U10c Sanitary Landfill for disposal. No hazardous or radiological waste was generated at this site

  1. Prevalence of Preventable Causes of Low Vision in Different Ages and Genders

    Directory of Open Access Journals (Sweden)

    Mohsen Akhgary

    2014-01-01

    Full Text Available Background: Much of the vision loss from age-related eye disease can be prevented. The purpose of this study is to determine 5Tthe prevalence5T 5Tof preventable5T 5Tcauses5T 5Tof low5T 5Tvision. Materials and Methods: In this study, files of 204 patients were evaluated5T.5T Low vision was defined as best-corrected visual acuity in the better eye between 20/70 to 20/200. Diagnosis of anterior and posterior segment disease was based on the eye examination that performed with Topcon slit-lamp biomicroscope and direct and indirect ophthalmoscope examination7T. Results: The prevalence of 5Tpreventable5T 5Tcauses of5T 5Tlow 5Twas respectively:5T diabetic retinopathy,5T 5Tin 335T 5Tpatients (5T16.18%, 5Tglaucoma 5Tin 6 5Tpatients (5T2.94%, 5Tand amblyopia5T in 5T2 patients (1%5T. Conclusion: The majority of cases have treatable and/or preventable causes; reduction of low vision or blindness can be achieved by appropriate screening strategies.

  2. Gas cogeneration system in Sapporo Therme

    Energy Technology Data Exchange (ETDEWEB)

    Kanematsu, Michihiko

    1988-06-01

    Sapporo Therme is a multi-purpose resort including a hot-water jumbo swimming pool having an area of about 130,000m/sup 2/ and a circumference of 800 m, 13 additional swimming pools with additional sizes, a hot-water slider, 16 types of saunas, an artificial sunbathing system, an athletic system, a restaurant, a cinema, tennis courts, and other outdoor facilities. Sapporo Therme uses a cogeneration system consisting of using LP gas(95% or more propane gas) to drive a 1,200 PS gas engine and supply motive power and lightening. At the same time, the cogeneration system collects gas engine waste heat and combines this heat with that from hot-water and steam boilers to supply hot water to swimming pools, roads, and room heaters. The ratio of waste heat collection rate to power generation efficiency is about 5.0. Sapporo Therme is thus the optimal facilities for cogeneration. (1 figs, 3 photos)

  3. The magic of television: Thinking through magical realism in recent TV [symposium

    Directory of Open Access Journals (Sweden)

    Lynne Joyrich

    2009-11-01

    Full Text Available After decades in which television has been marked as more banal than bewitching, recalling the "magic of television" is more likely to evoke a sense of wonder for the perceived innocence of an earlier televisual audience than for television itself. With TV offered on demand, captured with DVRs, downloaded or watched streaming on the Web, purchased as DVD sets, miniaturized for private screenings, jumbo-sized for public spectacles, monitored in closed circuits, and accessed for open forums, once-mysterious television flows have flowed to new media forms, giving TV an appearing/disappearing, now-you-see-it/now-you-don't magical act of its own. Has TV disappeared, or has it multiplied—redoubled each time it's sawed in half, replicating like rabbits pulled out of a hat? Is it still TV or something else when programs are screened (as if through a magic curtain via today's delivery systems?

  4. The genetics of resistance to powdery mildew in cultivated oats (Avena sativa L.): current status of major genes.

    Science.gov (United States)

    Hsam, Sai L K; Mohler, Volker; Zeller, Friedrich J

    2014-05-01

    The genetics of resistance to powdery mildew caused by Blumeria graminis f. sp. avenae of four cultivated oats was studied using monosomic analysis. Cultivar 'Bruno' carries a gene (Pm6) that shows a recessive mode of inheritance and is located on chromosome 10D. Cultivar 'Jumbo' possesses a dominant resistance gene (Pm1) on chromosome 1C. In cultivar 'Rollo', in addition to the gene Pm3 on chromosome 17A, a second dominant resistance gene (Pm8) was identified and assigned to chromosome 4C. In breeding line APR 122, resistance was conditioned by a dominant resistance gene (Pm7) that was allocated to chromosome 13A. Genetic maps established for resistance genes Pm1, Pm6 and Pm7 employing amplified fragment length polymorphism (AFLP) markers indicated that these genes are independent of each other, supporting the results from monosomic analysis.

  5. Would Aluminum and Nickel Content of Apricot Pose Health Risk to Human?

    Directory of Open Access Journals (Sweden)

    Gholamhossein DAVARYNEJAD

    2012-05-01

    Full Text Available Higher demands of food production for human consumption increased uses of fertilizers and other chemicals that arise in a major public problem and heavy-metal pollution. Levels of Aluminum and Nickel which affect mankind health in exact doses, were determined in fresh and dried samples of Jumbo Cot, Tom Cot, Gold Strike, Gold Bar, Bergeron, Bergarouge, Sweet Cot, Yellow cot and Zebra apricot cultivars to assess possible health risk of apricot (Prunus armeniaca L. consumption. Highest content of Al and Ni among all cultivars, where 9.71 and 2.14 mg/kg of dehydrated apricot samples. Fresh fruit samples maximally contain 2.9 and 0.425 mg/kg of Aluminum and Nickel respectively. Data analysis showed significant differences between cultivars for Al and Ni. Furthermore, to reveal the health-risk possibility of dried and fresh fruit consumption daily intake of elements and health-risk index were calculated and compared.

  6. Feeding of blue marlin Makaira nigricans off Mazatlan, Sinaloa, Mexico Alimentación del marlin azul Makaira nigricans del área de Mazatlán, Sinaloa, México

    Directory of Open Access Journals (Sweden)

    Leonardo Abitia-Cárdenas

    2010-01-01

    Full Text Available We analyzed the stomach contents of 52 blue marlins caught between October 2002 and October 2004 by the sport-fishing fleet of Mazatlan, Sinaloa, in the gulf of California, Mexico. Blue marlin feed on 15 food items. According to the index of relative importance (IRI, the most important prey were the frigate or bullet mackerel Auxis spp. (52% and jumbo squid Dosidicus gigas (30%.Se analiza el contenido estomacal de 52 marlines azules capturados por la flota de pesca deportiva que operó en el área de Mazatlan, Sinaloa, en el golfo de California, México, durante el periodo octubre 2002 a octubre 2004. El marlin azul se alimenta de 15 categorías alimenticias (ítemes, de las cuales las más importantes de acuerdo al índice de importancia relativa (IRI, fueron el pez melva Auxis spp. (52% y el calamar gigante Dosidicus gigas (30%.

  7. Effect of Bovine Plasma Protein on Autolysis and Gelation of Protein Extracted from Giant Squid (Dosidicus gigas Mantle

    Directory of Open Access Journals (Sweden)

    Laura Raquel Marquez-Alvarez

    2015-01-01

    Full Text Available The effect of bovine plasma protein (BPP on the inhibition of autolytic activity and its effect on the gelling properties of a protein concentrate (PC obtained from jumbo squid (Dosidicus gigas mantle were investigated. Sols and gels were prepared from the PC by adding different amounts of BPP (0, 1, and 2%. Dynamic oscillatory measurements indicated that systems with 1% BPP had a higher elastic modulus (G′, in which hydrophobic interactions were favored. Concerning the technological and textural quality of the gels, BPP caused a greater water holding capacity (WHC, force, cohesiveness, and elasticity, probably due to improvement of the electrostatic and hydrophobic interactions during gel formation. Scanning electron microscopy (SEM allowed visualization of the formation of more rigid and ordered gels with less porosity when BPP was added. Therefore, the addition of BPP improved the gelling capacity of proteins extracted from giant squid.

  8. Quiet innovation adds flexibility to global lending

    International Nuclear Information System (INIS)

    Pavey, Nigel.

    1993-01-01

    Few major mandates were won or lost in the first quarter of 1993, as the energy industry adopted a conservative approach to its financing needs. However, indications are that energy companies are coming back to the syndicated loan market after this quiet first quarter. Already, Enron, Shell Oil and Coastal have mandated substantial new facilities. Many more companies are expected back in the market over the new few months, including at least one jumbo for a major international name. A number of the industry's top names report that pricing is once again getting more aggressive in response to the high level of liquidity among lenders and a shortage of new mandates over the last few months. (Author)

  9. Special report. Twin Cities hospital breaks down ambulatory care, overcomes fears of outpatient care.

    Science.gov (United States)

    1995-01-06

    With payers pushing for shorter hospital stays and outpatient services generating growing shares of hospitals' revenues, experts everywhere are projecting the end of the traditional inpatient-oriented hospital. Those predictions have triggered a scramble by many hospital managers to adapt their organizations and empty beds to the expected predominance of same-day services. One Minnesota facility that surveyed the outpatient trend, however, found that its strategic options weren't limited to becoming a jumbo-sized outpatient clinic, explain David Allen, a partner with The Chancellor Group, Bloomington, Minn., and Daniel Weber, vice president of Fairview Southdale Hospital, Edina, Minn., in this special report. By understanding the multidimensional nature of ambulatory services and focusing its efforts on becoming a regional hub of healthcare services, Fairview Southdale has carved its own niche in a changing provider market.

  10. Engineering systems reliability, safety, and maintenance an integrated approach

    CERN Document Server

    Dhillon, B S

    2017-01-01

    Today, engineering systems are an important element of the world economy and each year billions of dollars are spent to develop, manufacture, operate, and maintain various types of engineering systems around the globe. Many of these systems are highly sophisticated and contain millions of parts. For example, a Boeing jumbo 747 is made up of approximately 4.5 million parts including fasteners. Needless to say, reliability, safety, and maintenance of systems such as this have become more important than ever before.  Global competition and other factors are forcing manufacturers to produce highly reliable, safe, and maintainable engineering products. Therefore, there is a definite need for the reliability, safety, and maintenance professionals to work closely during design and other phases. Engineering Systems Reliability, Safety, and Maintenance: An Integrated Approach eliminates the need to consult many different and diverse sources in the hunt for the information required to design better engineering syste...

  11. Decoding network dynamics in cancer

    DEFF Research Database (Denmark)

    Linding, Rune

    2014-01-01

    Biological systems are composed of highly dynamic and interconnected molecular networks that drive biological decision processes. The goal of network biology is to describe, quantify and predict the information flow and functional behaviour of living systems in a formal language and with an accur......Biological systems are composed of highly dynamic and interconnected molecular networks that drive biological decision processes. The goal of network biology is to describe, quantify and predict the information flow and functional behaviour of living systems in a formal language...... and with an accuracy that parallels our characterisation of other physical systems such as Jumbo-jets. Decades of targeted molecular and biological studies have led to numerous pathway models of developmental and disease related processes. However, so far no global models have been derived from pathways, capable...

  12. Evaluation of tomato genotypes against tomato mosaic virus (ToMV) and its effect on yield contributing parameters

    International Nuclear Information System (INIS)

    Ullah, N.; Ali, A.; Ahmad, M.; Din, N.; Ahmad, F.; Fahim, M.

    2017-01-01

    The use of resistant varieties is an effective, economic and environment friendly management of plant diseases particularly those caused by viruses. This paper reports, evaluation of 21 different tomato genotypes to find out resistance sources against Tomato mosaic virus (ToMV) and to study effect of the virus on yield contributing parameters. The virus identity was confirmed both by Direct Antibody Coating Enzyme Linked Immunoassay (DAC-ELISA) and differential host assay. Characteristic necrotic lesions were observed on differential hosts viz., Nicotiana tabacum var. White burly and Chenopodium amaranticolor after 10 and 3-4 days of inoculation, respectively. Upon ToMV inoculation, plants of accession No. 017902 developed no symptoms and were rated as highly resistant. Its resistance was further confirmed by both DAC-ELISA and indicator host assay, while the remaining genotypes displayed a range of symptoms. Plants of accession No. 017883 showed lowest percent disease index (PDI) and were rated as resistant, while plants of cultivar Red jumbo showed maximum PDI (44.97%) and were rated as susceptible. In susceptible genotypes average ELISA absorbance A405 value (2.19) was found higher than resistant one (1.05), while in control healthy plants ELISA absorbance A405 was 0.18. Maximum virus titre 2.73 and 0.91 were found in leaf and root tissues of cultivar Red jumbo, respectively. Among tested genotypes, one was highly resistant, one resistant, four moderately susceptible and 15 were susceptible. The virus significantly (p<=0.05) reduced the yield contributing parameters i.e. plant height, fresh shoot and root weight, dry shoot and root weight in susceptible genotypes. (author)

  13. Excavación de túneles en sección total y perforación en roca

    Directory of Open Access Journals (Sweden)

    Vié, G.

    1971-09-01

    Full Text Available There is a continuous increase in the size and importance of tunnels made in connection with public works, such as motor roads, and water supply systems, and also in other fields of engineering. The author reviews the new machinery now being used to excavate full section tunnels. He studies the various types of Jumbo machinery, helicoidal screw drilling equipment. Tunnellers, and similar devices, and their suitability in various types of rock. A description is given of projects where such equipment has been utilized, and the results are evaluated. Finally, the article deals with modern type hydraulic breaking super hammers, used in rock drilling.Cada día es mayor el número y la importancia de los túneles que se realizan tanto en el sector de las obras públicas (autopistas, abastecimientos de agua... como en los demás campos de la ingeniería. El autor pasa revista a la nueva maquinaria que actualmente se utiliza en la excavación de túneles a plena sección, examinando las características de diversos tipos de jumbos, perforadoras de tornillo helicoidal, «tunnelers», y su adecuación a los diferentes terrenos. Se describen algunas realizaciones en las que han intervenido estas máquinas, analizando los resultados por ellas obtenidos. Finalmente, el artículo se ocupa de los modernos supermartillos rompedores hidráulicos empleados en la perforación en roca.

  14. Effectiveness evaluation of existing noise controls in a deep shaft underground mine.

    Science.gov (United States)

    Lutz, Eric A; Reed, Rustin J; Turner, Dylan; Littau, Sally R; Lee, Vivien; Hu, Chengcheng

    2015-01-01

    Noise exposures and hearing loss in the mining industry continue to be a major problem, despite advances in noise control technologies. This study evaluated the effectiveness of engineering, administrative, and personal noise controls using both traditional and in-ear dosimetry by job task, work shift, and five types of earplug. The noise exposures of 22 miners performing deep shaft-sinking tasks were evaluated during 56 rotating shifts in an underground mine. Miners were earplug-insertion trained, earplug fit-tested, and monitored utilizing traditional and in-ear dosimetry. The mean TWA8 noise exposure via traditional dosimetry was 90.1 ± 8.2 dBA, while the mean in-ear TWA8 was 79.6 ± 13.8 dBA. The latter was significantly lower (p < 0.05) than the Mine Safety and Health Administration (MSHA) personal exposure limit (PEL) of 90 dBA. Dosimetry mean TWA8 noise exposures for bench blowing (103.5 ± 0.9 dBA), jumbo drill operation (103.0 ± 0.8 dBA), and mucking tasks (99.6 ± 4.7 dBA) were significantly higher (p < 0.05) than other tasks. For bench blowing, cable pulling, grinding, and jumbo drill operation tasks, the mean in-ear TWA8 was greater than 85 dBA. Those working swing shift had a significantly higher (p < 0.001) mean TWA8 noise exposure (95.4 ± 7.3 dBA) than those working day shift. For percent difference between traditional vs. in-ear dosimetry, there was no significant difference among types of earplug used. Reflective of occupational hearing loss rate trends across the mining industry, this study found that, despite existing engineering and administrative controls, noise exposure levels exceeded regulatory limits, while the addition of personal hearing protection limited excessive exposures.

  15. Design of large Francis turbine using optimal methods

    Science.gov (United States)

    Flores, E.; Bornard, L.; Tomas, L.; Liu, J.; Couston, M.

    2012-11-01

    Among a high number of Francis turbine references all over the world, covering the whole market range of heads, Alstom has especially been involved in the development and equipment of the largest power plants in the world : Three Gorges (China -32×767 MW - 61 to 113 m), Itaipu (Brazil- 20x750 MW - 98.7m to 127m) and Xiangjiaba (China - 8x812 MW - 82.5m to 113.6m - in erection). Many new projects are under study to equip new power plants with Francis turbines in order to answer an increasing demand of renewable energy. In this context, Alstom Hydro is carrying out many developments to answer those needs, especially for jumbo units such the planned 1GW type units in China. The turbine design for such units requires specific care by using the state of the art in computation methods and the latest technologies in model testing as well as the maximum feedback from operation of Jumbo plants already in operation. We present in this paper how a large Francis turbine can be designed using specific design methods, including the global and local optimization methods. The design of the spiral case, the tandem cascade profiles, the runner and the draft tube are designed with optimization loops involving a blade design tool, an automatic meshing software and a Navier-Stokes solver, piloted by a genetic algorithm. These automated optimization methods, presented in different papers over the last decade, are nowadays widely used, thanks to the growing computation capacity of the HPC clusters: the intensive use of such optimization methods at the turbine design stage allows to reach very high level of performances, while the hydraulic flow characteristics are carefully studied over the whole water passage to avoid any unexpected hydraulic phenomena.

  16. Design of large Francis turbine using optimal methods

    International Nuclear Information System (INIS)

    Flores, E; Bornard, L; Tomas, L; Couston, M; Liu, J

    2012-01-01

    Among a high number of Francis turbine references all over the world, covering the whole market range of heads, Alstom has especially been involved in the development and equipment of the largest power plants in the world : Three Gorges (China −32×767 MW - 61 to 113 m), Itaipu (Brazil- 20x750 MW - 98.7m to 127m) and Xiangjiaba (China - 8x812 MW - 82.5m to 113.6m - in erection). Many new projects are under study to equip new power plants with Francis turbines in order to answer an increasing demand of renewable energy. In this context, Alstom Hydro is carrying out many developments to answer those needs, especially for jumbo units such the planned 1GW type units in China. The turbine design for such units requires specific care by using the state of the art in computation methods and the latest technologies in model testing as well as the maximum feedback from operation of Jumbo plants already in operation. We present in this paper how a large Francis turbine can be designed using specific design methods, including the global and local optimization methods. The design of the spiral case, the tandem cascade profiles, the runner and the draft tube are designed with optimization loops involving a blade design tool, an automatic meshing software and a Navier-Stokes solver, piloted by a genetic algorithm. These automated optimization methods, presented in different papers over the last decade, are nowadays widely used, thanks to the growing computation capacity of the HPC clusters: the intensive use of such optimization methods at the turbine design stage allows to reach very high level of performances, while the hydraulic flow characteristics are carefully studied over the whole water passage to avoid any unexpected hydraulic phenomena.

  17. Effects of organic manure and crop rotation system on potato ...

    African Journals Online (AJOL)

    Effects of organic manure and crop rotation system on potato ( Solanum tuberosum L.) tuber ... Ethiopian Journal of Science and Technology ... (FYM); V2 = 2.5 t/h fresh sesbania green manure (FSB) V3 = 5 t/ha FYM; and V4 = 5 t/ha FYM +2.5 ...

  18. Studies on Using Cattle and Sheep Hydatid Cyst Fluid Instead of the Fetal Calf Serum in Leishmania Culture

    Directory of Open Access Journals (Sweden)

    Hossein Rezvan

    2013-12-01

    Full Text Available Background: Leishmania is a single cell parasite causing leishmaniasis, which is a common disease between humans and animals. Due to the importance of in-vitro culture of the parasite in leishmania research, developing new methods for in-vitro cultivation of the parasite has always been a goal for leishmania researchers. The main objective of7T 5T7Tthis study was to use sheep and bovine hydatid cyst fluids as alternatives for fetal calf serum (FCS in leishmania in-vitro5T culture5T. Materials and Methods: 7TA total of 5T7T1 million leishmania promastigotes were added to 4 flasks as follow5T7T. A f5T7Tlask containing DMEM medium with 105T7T% 5T7Tfetal bovine serum5T7T, a f5T7Tlask containing DMEM and 10% sheep hydatid cyst fluid5T7T, a f5T7Tlask containing DMEM medium with 105T7T% 5T7Tbovine hydatid cyst fluid and a5T7T f5T7Tlask containing DMEM medium alone. After 2, 45T7T, 5T7T7, 95T7T, 11, 5T7T21 and 24 days, the number of parasites were counted and compared5T7T. Results: The result of this study showed that, DMEM medium enriched with 10% sheep hydatid cyst fluid in 168 hours and medium enriched with 10% bovine hydatid cyst fluid in 96 hours can act as a good alternative for fetal bovine serum in the culture Leishmania major. Conclusion: 5TThe results showed that sheep and bovine hydatid cyst fluid can be used as alternatives to FCS for dense cultivation of leishmania. The results also showed that5T, 5Tthe growth of promastigotes in medium enriched with bovine cyst fluid is more rapid than the medium enriched with sheep5T c5Tyst fluid5T in5T the beginning of cultivation.

  19. Initial experience with 3T 3D-TOF MRA in the diagnosis of intracranial aneurysms

    International Nuclear Information System (INIS)

    Senba, Yoshiki; Takahashi, Shizue; Matsubara, Ichiro; Sadamoto, Kazuhiko; Miki, Hitoshi; Mochizuki, Teruhito

    2006-01-01

    We assessed the value of 3T 3D-time of flight (TOF) MR angiography (MRA) in the diagnosis of intracranial aneurysms compared with 1.5T 3D-TOF MRA. Twenty-one patients with 22 aneurysms underwent MRA at 1.5T and 3T. Images were interpreted by two radiologists. Each of nine aneurysms that had been considered ''definite'' at 1.5T 3D-TOF MRA were considered ''definite'' at 3T 3D-TOF MRA. Seven aneurysms that had been considered ''suspicious'' at 1.5T MRA were considered ''definite'' at 3T. And four aneurysms that had been considered ''suspicious'' at 1.5T were considered ''negative'' at 3T. We concluded that 3T 3D-TOF MRA is superior to 1.5T 3D-TOF MRA in the diagnosis of intracranial aneurysms. (author)

  20. Preliminary design for a 20 TeV Collider in a deep tunnel at Fermilab

    International Nuclear Information System (INIS)

    1985-01-01

    The Reference Design Study for a 20 TeV Collider demonstrated the technical and cost feasibility of a 20 TeV superconducting collider facility. Based on magnets of 3T, 5T, and 6.5T the Main Ring of the Collider would have a circumference of 164 km, 113 km, or 90 km. There would be six collision regions, of which four would be developed intially. The 5T and 6.5T rings would have twelve major refrigeration stations, while the 3T design would have 24 major refrigeration stations

  1. Homo sapiens are bilaterally symmetrical but not with toe length and ...

    African Journals Online (AJOL)

    A digital Vernier caliper was used to obtain direct linear measurements of the toe length of both feet; hallux (1T), second toe (2T), third toe (3T), fourth toe (4T), and the fifth toe (5T). Ten (10) possible toe-length ratios were also determined and named as follows; 1T/2T, 1T/3T, 1T/4T, 1T/5T, 2T/3T, 2T/4T, 2T/5T, 3T/4T, 3T/5T, ...

  2. Ordenación hidráulica, en Provenza (Francia

    Directory of Open Access Journals (Sweden)

    Vié, Georges

    1967-06-01

    Full Text Available French Provence has an irregular rainfall and a large need of water, both for urban use and for the irrigation of its fertile soil. Local needs, the general progress and the development of the Electricité de France (E.D.F. have led to the formation of the Canal Society of Provence, from which important improvements in the existing canal network are to be expected, and also in the provision of new sources of water. As the number of works and reforms are large, the author has limited himself to a description of the more outstanding ones. In relation to the construction machinery used in these works, special mention should be made of a jumbo which drills and clears away the debris after firing the charges. This is a very important problem, which appears to be finally solved, so that in the near future the rate of drilling in galleries will be substantially improved. Another important feature, which could be usefully applied to hydraulic projects with shortage of water, is the use of pressurized irrigation networks and aspersion type watering.La Provenza francesa es una región de régimen pluvial irregular y muy necesitada de aguas, tanto para usos urbanos como para la irrigación de sus fértiles tierras. Las necesidades locales, la evolución de los tiempos y la aparición de Electricité de France (E.D.F. en Francia se han conjugado para crear la Sociedad del Canal de Provenza, de la que se espera grandes mejoras de la red de canalizaciones existentes y nuevas aportaciones de agua. Como el número de obras y reformas es numeroso, el autor se ha limitado a describir las más destacadas. Merece particular atención la presencia, entre la maquinaria auxiliar de construcción, de un «jumbo» que perfora y limpia el escombro después de la pega, problema de sumo interés que, actualmente, parece se halla en vías de solución definitiva, con lo que, en un futuro próximo, se podrán mejorar los avances medios diarios en la perforación de galer

  3. Hábitos alimentarios de Dosidicus gigas (D' Orbigny, 1835 (Cephalopoda: Teuthoidea frente a la costa centro-sur de Chile Feeding habits of Dosidicus gigas (D'Orbigny, 1835 (Cephalopoda: Teuthoidea in the central-south coast off Chile

    Directory of Open Access Journals (Sweden)

    PATRICIO ULLOA

    2006-12-01

    Full Text Available Se estudiaron los hábitos alimentarios del calamar rojo Dosidicus gigas (D'Orbigny, 1835 frente a la costa de Chile centro-sur, durante el invierno del año 2005. Se examinaron un total de 52 estómagos, en todos los cuales había contenido alimentario. Los ejemplares provenían de pescas efectuadas por la flota arrastrera industrial que opera entre 36°39' S y 38°55'S sobre la merluza común Merluccius gayi (Guichenot 1848 y a una profundidad media de 290 m sobre la plataforma continental. Para la descripción del espectro trófico, alimento principal y el establecimiento de las eventuales diferencias sexuales u ontogenéticas en la frecuencia de aparición de los ítemes presa, se utilizaron los métodos numérico, gravimétrico, de frecuencia de ocurrencia, índice de importancia relativa (IIR e índice de similitud porcentual (ISP. No se observaron diferencias sexuales ni ontogenéticas en la frecuencia de aparición de los ítemes presa. Los resultados muestran que D. gigas es un depredador oportunista, principalmente ictiófago, y secundariamente malacófago (incluye el canibalismo y carcinófago. Se discuten los eventuales motivos e implicancias de tal conductaA study on the feeding habits of the jumbo squid Dosidicus gigas (D'Orbigny, 1835 was carried out during the winter season 2005, in waters of the Chilean central and southern Pacific. A total of 52 jumbo squid stomachs from the fishing of the continental slope were collected and examined, in the Eighth and Ninth regions, between 36°40' S and 38°55'S, at an average depth of 290 m. To determine the trophic spectrum, the feeding preferences and the importance of the sex and ontogenetic condition in the diet, the numeric, gravimetric, frequency of occurrence methods, and the index of relative importance and dietary similarity were utilized. The frequency of the prey did not vary with relation to the sex and ontogenetic conditions, and was besides a hight trophic similarity in such

  4. Análise dialélica da capacidade combinatória de cultivares de tomateiro Diallel analysus of the combining ability of tomato cultivars

    Directory of Open Access Journals (Sweden)

    Antonio Teixeira do Amaral Júnior

    1996-01-01

    Full Text Available Os cultivares de tomateiro (Lycopersicon esculentum Mill. Ângela I.5100, Floradade, IPA-05, IPA-06, Jumbo e Santa Clara, e os 15 possíveis híbridos F1s foram avaliados quanto à produção de frutos comerciáveis (PFC, espessura média da polpa (EMP, número médio de lóculos por fruto (NML e teor de sólidos solúveis (TSS, com o objetivo de identificar parentais e híbridos promissores para programas de melhoramento. A análise dialélica, com base no método de Griffing, revelou a predominância dos efeitos gênicos não aditivos para o caráter PFC, ao contrário de EMP, enquanto NML acusou equivalência para os efeitos aditivos e não aditivos. Em decorrência das estimativas da capacidade geral de combinação (Gi os cultivares Ângela I.5100, IPA-05 e IPA-06 são indicados para o desenvolvimento de programas de melhoramento.The tomato (Lycopersicon esculentum Mill. cultivars Ângela I.5100, Floradade, IPA-05, IPA-06, Jumbo and Santa Clara and their diallelic crosses were evaluated for commercial fruit weight (CFW, average thickness of the pule (ATP, average number of loculi per fruit (NLF and content of soluble solids (CSS. The objective was to identify the superior progenitors and the promising hybrids for plant breeding programs. The diallel analysis based on Griffings Methodology, showed a prevailing non-additive genic effects for CFW, the opposite being observed for ATP meanwhile NLF showed an equal value for additive and non-additive effects. Based on general combining ability estimates, the cultivars Ângela I.5100, IPA-05 and IPA-06, are indicated to plant breeding programs.

  5. Perforaciones de los grandes subterráneos y los métodos y máquinas modernos

    Directory of Open Access Journals (Sweden)

    Vié, G.

    1973-11-01

    Full Text Available The drilling of large underground tunnels, either for mines or public works, should be approached according to patterns characteristic in all these large projects, which are: safety, strength, economy, etc. Because of the differing techniques and use of the various machines in existence for such an end, the one most advantageous in each case should be chosen. Experience obtained in several years of work and testing teaches us that when the ground is soft, we obtain the best results with the rotary drill; otherwise, it is advisable to use the rotary-percussion drill. Finally, the automatic jumbo has been successfully used, which is very maneuverable and eliminates many of the inconveniences produced by drills, such as: noise, high air consumption and frequent jam-ups. It can be fed with electricity, diesel or diesel-electrical power. It is frequently used, especially in turnpikes.La perforación de los grandes subterráneos, bien sea para trabajos de minas o de obras públicas, debe acometerse bajo unos patrones característicos en todas estas grandes obras, como son: la seguridad, resistencia, economía, etc. Debido a la diferente técnica y utilización de las diversas máquinas existentes para tal fin, deben elegirse las más ventajosas en cada caso. La experiencia de varios años de trabajo y ensayos nos dice que cuando el terreno es blando los mejores resultados los obtenemos con la perforadora rotativa; en caso contrario, conviene utilizar la perforadora roto-percutiva. Últimamente se viene empleando, con éxito, el jumbo automático, el cual tiene una gran maniobrabilidad y elimina parte de los inconvenientes producidos por las perforadoras, tales como: ruido, elevado consumo de aire y blocajes frecuentes. Puede alimentarse con energía eléctrica, diésel o diésel-eléctrica. Su utilización es frecuente, sobre todo en la construcción de autopistas.

  6. Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value

    DEFF Research Database (Denmark)

    Johnson, Thorsten R C; Bayrhof, Nicole; Huber, Armin

    2007-01-01

    Our aim was to determine the diagnostic value of myocardial tagging sequences with regard to the evaluable share of the cardiac cycle. Thirty-three patients were examined at 1.5 T using tagging sequences with gradient-echo (GRE) readout, 18 patients at 1.5 T with steady-state free precession (SSF...

  7. 27 CFR 46.116 - Issuance, distribution, and examination of special tax stamps.

    Science.gov (United States)

    2010-04-01

    ... multiple locations, TTB will send to the taxpayer's principal place of business (or principal office in the... attachment to TTB Form 5630.5t required by § 46.101(b)(2). (b) Distribution of special tax stamps for... for each location listed on the attachment to TTB Form 5630.5t and that the information on each stamp...

  8. Evidence favoring the involvement of CC chemokine receptor (CCR) 5 in T-lymphocyte accumulation in optic neuritis

    DEFF Research Database (Denmark)

    Sørensen, Torben Lykke; Ransohoff, R M; Jensen, J

    2003-01-01

    To define the relationships between levels of chemokine receptor (CCR)5+ T-cells in blood and cerebrospinal fluid (CSF) of optic neuritis (ON) and control patients (CON).......To define the relationships between levels of chemokine receptor (CCR)5+ T-cells in blood and cerebrospinal fluid (CSF) of optic neuritis (ON) and control patients (CON)....

  9. Dynamic nuclear polarization tests in some polymers for polarized targets

    International Nuclear Information System (INIS)

    Brandt, B. van den; Hautle, P.; Konter, J.A.; Mango, S.; Bunyatova, E.I.

    1998-01-01

    The results of dynamic polarization tests in polyethylene (PE) and ethylene propylene copolymer (EPC), doped with the stable free radical 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO), are presented. Sizable proton polarizations have been achieved in a magnetic field of 2.5 T at a temperature below 0.3 K and 5T at 1 K

  10. A Simple Alternative Method for the Synthesis of Aromatic Dialdehydes

    OpenAIRE

    KOZ, Gamze; ASTLEY, Demet; ASTLEY, Stephen

    2011-01-01

    Aromatic dialdehydes were synthesized from 5-t-butylsalicylaldehyde and o-vanilline in good yields using paraformaldehyde, hydrobromic acid and catalytic amounts of sulfuric acid in one step which was previously unavailable with present methods. Key Words: aromatic dialdehydes, bromomethylation, 5-t-butylsalicylaldehyde, o-vanilline. 

  11. A Simple Alternative Method for the Synthesis of Aromatic Dialdehydes

    OpenAIRE

    KOZ, Gamze; ASTLEY, Demet; ASTLEY, Stephen Thomas

    2012-01-01

    Aromatic dialdehydes were synthesized from 5-t-butylsalicylaldehyde and o-vanilline in good yields using paraformaldehyde, hydrobromic acid and catalytic amounts of sulfuric acid in one step which was previously unavailable with present methods. Key Words: aromatic dialdehydes, bromomethylation, 5-t-butylsalicylaldehyde, o-vanilline. 

  12. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  13. Adhesion science

    CERN Document Server

    Comyn, John

    1997-01-01

    The use of adhesives is widespread and growing, and there are few modern artefacts, from the simple cereal packet, to the jumbo jet, that are without this means of joining. Adhesion Science provides an illuminating account of the science underlying the use of adhesives, a branch of chemical technology which is fundamental to the science of coatings and composite materials and to the performance of all types of bonded structures. This book guides the reader through the essential basic polymer science, and the chemistry of adhesives in use at present. It discusses surface preparation for adhesive bonding, and the use of primers and coupling agents. There is a detailed chapter on contact angles and what can be predicted from them. A simple guide on stress distribution joints and how this relates to testing is included. It also examines the interaction of adhesives and the environment, including an analysis of the resistance of joints to water, oxygen and ultra-violet light. Adhesion Science provides a comprehens...

  14. A new dawn for CMS

    CERN Multimedia

    2007-01-01

    Supported by a gigantic crane and a factory-size room full of enthusiasm, the central barrel of CMS made its final journey underground on 28 February. The central section of the CMS detector starts its dramatic 10-hour descent underground.Several hours (and 100 metres) later, the massive barrel rests on the cavern floor. CMS scientists, journalists, photographers and members of the transport crew basked in the final rays of the 'solenoid-set' on 28 February as the central barrel of the CMS detector sinks below the horizon and began its ten-hour descent into the cavern 100 metres below. Thirteen metres long and weighing as much as five jumbo jets (1920 tonnes), the barrel is the largest of the 15 chunks of CMS detector that are being lowered one by one into the cavern. 'This is a challenging feat of engineering, as there are just 20 cm of leeway between the detector and the walls of the shaft,' said Austin Ball, Technical Coordinator of CMS. The section of the detector, which contains the solenoid of the magne...

  15. Quiet tunneling method in hard rock mass by cutting grooves and fracturing rock; Mizo wo hori, iwa wo wari, katai tonneru wo shizukani kussaku

    Energy Technology Data Exchange (ETDEWEB)

    Noma, T. [Fujita Corp., Tokyo (Japan)

    1998-08-15

    Where blasting cannot be applied due to large vibration and noise, adoption of mechanical tunneling is essential to tunneling of hard rock. In tunneling of hard rock, the existing of free surface is important. The free surface means a surface which does not restrict destruction on fracturing and it is important to form a continuous free surface efficiently and economically. The development of a new free surface forming engineering method is described. It requires no exclusive machines and all drilling works can be operated with general drill jumbo machine. In this new engineering method, the free surface is formed by continuous drilling of a single hole. Spinning anti-bend (SAB) rod is inserted into the existing drilled hole and a drill bit generates the free surface by contact with and blow the SAB rod. The procedure of the continuous drilling, an application example and the features of the procedure are described. This method has an ability to form a free surface more than 3.5m{sup 2}h even for rock bed wit compression strength more than 200MPa. 2 refs., 8 figs.

  16. Stanford Synchrotron Radiation Laboratory 1992 activity report

    International Nuclear Information System (INIS)

    Cantwell, K.

    1993-01-01

    Under SLAC's supervision, the SPEAR ring and injector system were operated for the first time in a truly dedicated mode for user experimentation. In October, SSRL became a division of SLAC. With that organizational change, SSRL became fully responsible for the operation, maintenance and improvement of SPEAR and its injection accelerators. At the same time, other radiation sources were studied. Free electron lasers providing enormous peak brightnesses and time average brightnesses about two orders of magnitude greater than the machines presently being constructed or commissioned were the object of one line of analysis. Ultra-short pulse beams at lower photons energies were also studied. These, as well, are described in Chapter 2. Significant gains were also made on the beam lines. Perhaps the most dramatic was the introduction of YB 66 crystals into the Jumbo monochromator, as described in Chapter 3. Looking to the future, SSRL held a workshop on Fourth Generation Light Sources in February and two workshops in conjunction with the Users Meeting. The impact of the high quality running is demonstrated by the many high quality experimental programs performed on SPEAR during the year. These are described in Chapter 6

  17. A method to press powder at 6000 ton using small amount of explosive

    Science.gov (United States)

    Hilmi, Ahmad Humaizi; Azmi, Nor Azmaliana; Ismail, Ariffin

    2017-12-01

    Large die hydraulic press forces are one of the key instruments in making jumbo planes. The machine can produce aircraft components such as wing spars, landing gear supports and armor plates. Superpower nations such as USA, Russia, Germany, Japan, Korea and China have large die hydraulic press which can press 50,000 tons. In Malaysia, heavy-duty press is available from companies such as Proton that builds chassis for cars. However, that heavy-duty press is not able to produce better bulkhead for engines, fuselage, and wings of an aircraft. This paper presents the design of an apparatus that uses 50 grams of commercial grade explosives to produce 6000 tons of compaction. This is a first step towards producing larger scale apparatus that can produce 50,000-ton press. The design was done using AUTODYN blast simulation software. According to the results, the maximum load the apparatus can withstand was 6000 tons which was contributed by 50 grams of commercial explosive(Emulex). Explosive size larger than 50 grams will lead to catastrophic failure. Fabrication of the apparatus was completed. However, testing of the apparatus is not presented in this article.

  18. [Family planning can reduce maternal mortality].

    Science.gov (United States)

    Potts, M

    1987-01-01

    Although the maternal mortality rate receives no newspaper headlines, the number of mothers dying throughout the world is equivalent to a full jumbo jet crashing every 5 hours. Population surveys carried out between 1981-83 by Family Health International indicated maternal mortality rates of 1.9/1000 live births in Menoufia, Egypt, and 7.2/1000 in Bali, Indonesia. 20-25% of all deaths in women aged 15-49 were directly related to pregnancy and delivery, compared to 1% in western countries where there is better prenatal care, medical assistance in almost all deliveries, and elimination of most high risk pregnancies through voluntary fertility control. Maternal mortality could be controlled by teaching traditional midwives to identify high risk patients at the beginning of their pregnancies and to refer them to appropriate health services. Maternal survival would also be improved if all women were in good health at the beginning of pregnancy. Families should be taught to seek medical care for the mother in cases of prolonged labor; many women arrive at hospitals beyond hope of recovery after hours or days of futile labor. Health policy makers should set new priorities. Sri Lanka, for example, has a lower per capita income than Pakistan, but also a lower maternal mortality rate because of better use of family planning services, more emphasis on prenatal care, and a tradition of care and attention on the part of the public health services.

  19. RENDIMIENTO DE 12 HÍBRIDOS COMERCIALES DE ZANAHORIA (Daucus carota L. EN EL CAMPO Y EN LA PLANTA DE EMPAQUE

    Directory of Open Access Journals (Sweden)

    Fernando Richmond-Zumbado

    2010-01-01

    Full Text Available Se evaluaron 12 híbridos comerciales de zanahoria (Daucus carota L. en Cot de Oreamuno, Cartago, Costa Rica, con el objetivo de evaluar el rendimiento en el campo y la planta de empaque, de junio a octubre del 2007. Los híbridos evaluados fueron: Bangor F1, Big Sur, Bolero F1, Concerto F1 (VAC 03 F1, XCR3688, Esperanza, Nandrin F1, Napoli F1, S-505, Spearhead, Trinity y Sirkana. Se obtuvo el número y peso de las raíces de los híbridos comerciales clasificadas en raíces totales, comerciales y diferentes variables de rechazo; en el campo y en la planta de empaque. Los híbridos con el mayor rendimiento comercial en campo y en planta empacadora, en orden decreciente, fueron: Bangor F1, Esperanza, Concerto F1, Nandrin F1 y Sirkana. Los materiales con menor rechazo en campo fueron Nandrin F1, Sirkana y Bangor F1, y en planta empacadora fueron: Big Sur, Sirkana, Napoli F1, Bolero F1 y XCR3688. Las principales causas de rechazo de la zanahoria en el campo y en la planta empacadora fueron: raíces bifurcadas, con rajadura, raíz pequeña y tamaño jumbo.

  20. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Science.gov (United States)

    Charpentier, Isabelle; Staszyc, Alicia B.; Wellner, Julia S.; Alejandro, Vanessa

    2017-06-01

    As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a 100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  1. Tolerância a baixas temperaturas de cultivares de abacate (Persea americana Mill.

    Directory of Open Access Journals (Sweden)

    Soares Nilberto Bernardo

    2002-01-01

    Full Text Available Em experimento realizado no Núcleo de Agronomia do Sudoeste/IAC, em Capão Bonito (SP, observou-se o comportamento de 13 cultivares de abacate com seis anos de idade: Geada, Pollock e Simmonds (raça antilhana; Antoniolli, Breda, Campinas, Ermor, Jumbo, Margarida, Ouro verde, Reis e Solano (híbridos de antilhana x guatemalense e Fuerte (híbrido de mexicana x guatemalense em relação às baixas temperaturas. As temperaturas do ar registradas no posto meteorológico do local foram: -2,8degreesC; -0,4degreesC; -0,2degreesC e -1,8degreesC, respectivamente, nos dias 17; 18; 20 e 21 de julho de 2000. A cultivar Fuerte mostrou-se mais tolerante às baixas temperaturas, não apresentando injúrias nas plantas nem queda de frutos; as cultivares híbridas de antilhana x guatemalense apresentaram diferenças de tolerância ao frio; enquanto as antilhanas foram severamente injuriadas.

  2. Drug-printing by flexographic printing technology--a new manufacturing process for orodispersible films.

    Science.gov (United States)

    Janssen, Eva Maria; Schliephacke, Ralf; Breitenbach, Armin; Breitkreutz, Jörg

    2013-01-30

    Orodispersible films (ODFs) are intended to disintegrate within seconds when placed onto the tongue. The common way of manufacturing is the solvent casting method. Flexographic printing on drug-free ODFs is introduced as a highly flexible and cost-effective alternative manufacturing method in this study. Rasagiline mesylate and tadalafil were used as model drugs. Printing of rasagiline solutions and tadalafil suspensions was feasible. Up to four printing cycles were performed. The possibility to employ several printing cycles enables a continuous, highly flexible manufacturing process, for example for individualised medicine. The obtained ODFs were characterised regarding their mechanical properties, their disintegration time, API crystallinity and homogeneity. Rasagiline mesylate did not recrystallise after the printing process. Relevant film properties were not affected by printing. Results were comparable to the results of ODFs manufactured with the common solvent casting technique, but the APIs are less stressed through mixing, solvent evaporation and heat. Further, loss of material due to cutting jumbo and daughter rolls can be reduced. Therefore, a versatile new manufacturing technology particularly for processing high-potent low-dose or heat sensitive drugs is introduced in this study. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Pemanfaatan Hasil Eksplorasi Plasmanutfah Jeruk Nusantara

    Directory of Open Access Journals (Sweden)

    Emi Budiyati

    2016-03-01

    Full Text Available Indonesia memiliki keanekaragaman  jenis jeruk unggul  lokal maupun nasional   yang tersebar diseluruh nusantara dari sabang sampai merauke,  dan berpotensi  dikembangkan serta didayagunakan untuk mendukung ketahanan pangan, khususnya untuk memenuhi kebutuhan vitamin dan mineral masyarakat seiring  dengan bertambahnya penduduk yang terus meningkat dari tahun ketahun.  Penelitian  bertujuan untuk identifikasi hasil eksplorasi plasmanutfah jeruk nusantara  berdasarkan kemanfaatan sesuai jenisnya.  Penelitian dilakukan dari tahun 2010 -2013  diseluruh daerah sentra jeruk  Maluku Utara, Maluku tenggara,  Kalimantan Timur, dan Jawa Timur. Metodologi dengan  survei  dan exploratif,  kordinasi dengan Diperta, BPTP, Kebun Raya LIPI serta wawancara dengan penduduk lokal.  Hasil penelitian telah mendapat 30 Asesi Jeruk yang terdiri  citrus  reculata, citrus maxima,  citrus  ambicarpha dan   citrus aurantivolia dan  Menjadi  3 macam jenis berdasarkan pemanfaatannya  yaitu sebagai  buah segar (Pamelo, Keprok dan Manis, olahan dan jenis  biofarmaka (Nipis. Nipis Jumbo, Jerpaya, dan  Jari Buda membukaKata kunci:   buah, eksplorasi, jeruk, plasmanutfah, varietas

  4. CROSS-FRONTIER PUBLIC TRANSPORT: Y BUS

    CERN Multimedia

    CERN Housing Service

    2002-01-01

    'Y' buses cover the journey between Val Thoiry in France (shopping centre including'Migros' and other stores) and Blandonnet in Switzerland, where they stop outside the 'Jumbo' shop, now renamed 'Carrefour'. In France, the buses connect up Thoiry, Sergy and St. Genis, then cross the border to stop outside CERN, Meyrin, before continuing towards Geneva along the 'Route de Meyrin', stopping outside the 'La Tour' hospital, then at the terminus Blandonnet. The normal fare on French territory with a slight incursion into Switzerland for this purpose as far as CERN, Meyrin, is 1.20 Euros per single journey (ticket valid for one hour). The same amount is charged for any single journey in Switzerland. For example, the cost of a single journey between St. Genis and the 'La Tour' hospital would be 2.40 Euros. The season ticket ('Abonnement de Travail') opens the right to purchase a ticket valid over any period of seven days which entitles the holder to as many journeys as required between the bus stop nearest to the pl...

  5. Application of advanced technologies for uranium mining and processing at Narwapahar and Turamdih projects

    International Nuclear Information System (INIS)

    Puri, R.C.; Verma, R.P.

    1991-01-01

    Uranium Corporation of India Ltd. (UCIL) has started construction work on two mines, one each at Narwapahar and Turamdih Projects and a combined processing plant at Turamdih as a part of the country's ambitious Atomic Energy Programme. The adoption of latest concept of declines as mine entries will enable completion of project in 4 years only and will also allow large scale mechanisation underground. Use of latest world technology of LPD trucks, LHD vehicles, drill jumbos, scissor lift, passenger carrying and service vehicles will result in rapid development progress rates and large production from concentrated work places. Mine lay-out providing access ways in waste to ore bodies and use of high capacity high pressure fans for ventillation will enable adequate control on radon in mine workings. Process Plant has been designed based on experiences of Jaduguda operations and information/data of several most modern operations of overseas countries such as Canada, USA, South Africa, France and Australia. Use of horizontal belt filters for filtration, draught tube-circulators for leaching and Himsley continuous counter current fluidized bed ion exchange system provide high efficiency and flexibility for extraction of uranium together with low capital as well as operation and maintenance costs. The paper details the various methods, processes and equipment giving the benefits derived from each. (author). 1 ref., 10 figs., 2 tabs

  6. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  7. Would Aluminum and Nickel Content of Apricot Pose Health Risk to Human?

    Directory of Open Access Journals (Sweden)

    Gholamhossein DAVARYNEJAD

    2012-05-01

    Full Text Available Higher demands of food production for human consumption increased uses of fertilizers and other chemicals that arise in a major public problem and heavy-metal pollution. Levels of Aluminum and Nickel which affect mankind health in exact doses, were determined in fresh and dried samples of �Jumbo Cot�, �Tom Cot�, �Gold Strike�, �Gold Bar�, Bergeron�, �Bergarouge�, �Sweet Cot�, �Yellow cot� and �Zebra� apricot cultivars to assess possible health risk of apricot (Prunus armeniaca L. consumption. Highest content of Al and Ni among all cultivars, where 9.71 and 2.14 mg/kg of dehydrated apricot samples. Fresh fruit samples maximally contain 2.9 and 0.425 mg/kg of Aluminum and Nickel respectively. Data analysis showed significant differences between cultivars for Al and Ni. Furthermore, to reveal the health-risk possibility of dried and fresh fruit consumption daily intake of elements and health-risk index were calculated and compared.

  8. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Directory of Open Access Journals (Sweden)

    Charpentier Isabelle

    2017-01-01

    Full Text Available As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a ~100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  9. The progress and efficiency on SFR

    International Nuclear Information System (INIS)

    Li Shisen.

    1985-01-01

    The study comprehends an analysis of construction management at the work site of SFR, the final repository for low and medium level nuclear waste, situated in Forsmark. The period of analysis is 1985. During this year, the most intensive part of the rock excavation work of totaly 430,000 solid cubic metres took place. Many tunnels and big chambers as well as a huge silo were driven. Many drawings and figures are given to show how the project was going on and how the construction efficiency was during the year of 1985. SFR is a highly mechanized underground project. Based on the analysis of the composition of the construction costs in SFR, the work study points out that the machine costs is the biggest part in the construction costs, and that there is a close relation between the construction costs and machine management. Some experience in reducing construction costs and some experience in construction management are introduced in detail. In order to improve the machine management, attention should be paid to increase the utilization ratio of machines. A preliminary study of time utilization ratio of drill jumbo and bolting rig is given. (orig./HP)

  10. 2011 Ground Testing Highlights Article

    Science.gov (United States)

    Ross, James C.; Buchholz, Steven J.

    2011-01-01

    Two tests supporting development of the launch abort system for the Orion MultiPurpose Crew Vehicle were run in the NASA Ames Unitary Plan wind tunnel last year. The first test used a fully metric model to examine the stability and controllability of the Launch Abort Vehicle during potential abort scenarios for Mach numbers ranging from 0.3 to 2.5. The aerodynamic effects of the Abort Motor and Attitude Control Motor plumes were simulated using high-pressure air flowing through independent paths. The aerodynamic effects of the proximity to the launch vehicle during the early moments of an abort were simulated with a remotely actuated Service Module that allowed the position relative to the Crew Module to be varied appropriately. The second test simulated the acoustic environment around the Launch Abort Vehicle caused by the plumes from the 400,000-pound thrust, solid-fueled Abort Motor. To obtain the proper acoustic characteristics of the hot rocket plumes for the flight vehicle, heated Helium was used. A custom Helium supply system was developed for the test consisting of 2 jumbo high-pressure Helium trailers, a twelve-tube accumulator, and a 13MW gas-fired heater borrowed from the Propulsion Simulation Laboratory at NASA Glenn Research Center. The test provided fluctuating surface pressure measurements at over 200 points on the vehicle surface that have now been used to define the ground-testing requirements for the Orion Launch Abort Vehicle.

  11. Penetration, Post-penetration Development, and Reproduction of Meloidogyne incognita on Cucumis melo var. texanus.

    Science.gov (United States)

    Faske, T R

    2013-03-01

    Cucumis melo var. texanus, a wild melon commonly found in the southern United States and two accessions, Burleson Co. and MX 1230, expressed resistance to Meloidogyne incognita in preliminary experiments. To characterize the mechanism of resistance, we evaluated root penetration, post-penetration development, reproduction, and emigration of M. incognita on these two accessions of C. melo var. texanus. Additionally, we evaluated 22 accessions of C. melo var. texanus for their reaction against M. incognita in a greenhouse experiment. Fewer (P ≤ 0.05) J2 penetrated the root system of C. melo var. texanus accessions (Burleson Co. and MX 1230) and C. metuliferus (PI 482452) (resistant control), 7 days after inoculation (DAI) than in C. melo 'Hales Best Jumbo' (susceptible control). A delayed (P ≤ 0.05) rate of nematode development was observed at 7, 14, and 21 DAI that contributed to lower (P ≤ 0.05) egg production on both accessions and C. metuliferus compared with C. melo. Though J2 emigration was observed on all Cucumis genotypes a higher (P ≤ 0.05) rate of J2 emigration was observed from 3 to 6 DAI on accession Burleson Co. and C. metuliferus than on C. melo. The 22 accessions of C. melo var. texanus varied relative to their reaction to M. incognita with eight supporting similar levels of nematode reproduction to that of C. metuliferus. Cucumis melo var. texanus may be a useful source of resistance against root-knot nematode in melon.

  12. Asparagus chain: Fifth year production of different genotypes and postharvest behaviour.

    Directory of Open Access Journals (Sweden)

    Erika Kirschenbilder

    2015-01-01

    Full Text Available The objective of this investigation was to study greenhouse precocious spears yield of three genotypes of asparagus on its fifth harvest season. The trial was established at the Faculty of Agricultural, Pontifical Catholic University of Argentina, on November, 15, 2006. 19 different harvests were made from 04/09/2012 to 22/10/2012, one every two days. A multifactor ANOVA-LSD test (P>0.05 was performed. Variables analyzed were: total productivity and commercial productivity (PFT and PFC, total number of spears and commercial number of spears (NTT and NTC; caliber distribution (DC: Jumbo (J, Extra-Large (XL, Large (L, Medium (M and Small (S and finally, quality defects (D: spiked spears (TE; short spears (TC and other defects (OD. During the post-harvest period, bundles (A, trays (BA and polyethylene bags were used to study fresh weight evolution (EPF; daily fresh weight loss (PPFD and average fresh weight during the post-harvest period (PPFP. Italian breeds yielded above 9 t/ha, twice the Argentinean national average. According to the production results, Giove stood out regarding PFT, PFC, NTT, NTC and a proper DC, where the 70% of spears measured L and XL. With regard to postharvest behavior, it was found that the lowest degree of dehydration was obtained by using bags and trays.

  13. The role of water on the structure and mechanical properties of a thermoplastic natural block co-polymer from squid sucker ring teeth.

    Science.gov (United States)

    Rieu, Clément; Bertinetti, Luca; Schuetz, Roman; Salinas-Zavala, Cesar Ca; Weaver, James C; Fratzl, Peter; Miserez, Ali; Masic, Admir

    2016-09-02

    Hard biological polymers exhibiting a truly thermoplastic behavior that can maintain their structural properties after processing are extremely rare and highly desirable for use in advanced technological applications such as 3D-printing, biodegradable plastics and robust composites. One exception are the thermoplastic proteins that comprise the sucker ring teeth (SRT) of the Humboldt jumbo squid (Dosidicus gigas). In this work, we explore the mechanical properties of reconstituted SRT proteins and demonstrate that the material can be re-shaped by simple processing in water and at relatively low temperature (below 100 °C). The post-processed material maintains a high modulus in the GPa range, both in the dry and the wet states. When transitioning from low to high humidity, the material properties change from brittle to ductile with an increase in plastic deformation, where water acts as a plasticizer. Using synchrotron x-ray scattering tools, we found that water mostly influences nano scale structure, whereas at the molecular level, the protein structure remains largely unaffected. Furthermore, through simultaneous in situ x-ray scattering and mechanical tests, we show that the supramolecular network of the reconstituted SRT material exhibits a progressive alignment along the strain direction, which is attributed to chain alignment of the amorphous domains of SRT proteins. The high modulus in both dry and wet states, combined with their efficient thermal processing characteristics, make the SRT proteins promising substitutes for applications traditionally reserved for petroleum-based thermoplastics.

  14. Sample of superconducting wiring from the LHC

    CERN Multimedia

    The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable to the weight of a jumbo jet. Coil winding requires great care to prevent movements as the field changes. Friction can create hot spots wh...

  15. 3',5'-diiodothyronine in health and disease: studies by a radioimmunoassay

    International Nuclear Information System (INIS)

    Chopra, I.J.; Geola, F.; Solomon, D.H.; Maciel, R.M.B.

    1978-01-01

    An RIA has been developed for 3'5'-diiiodothyronine (3',5'-T 2 ) in unextracted serum. Interference in binding of radioactive 3',5'-T 2 to anti-3',5'-T 2 was minimized by using phosphate buffer and merthiolate. The detection threshold of the RIA was 2.5 ng/dl. Recovery of nonradioactive 3',5'-T 2 averaged 99%. T 4 , T 3 , and rT 3 cross-reacted with anti-3',5'-T 2 antibody 0.0025, 2 concentrations in ng/dl were 2.4 in 53 normal subjects, 4.2 in 7 hypothyroid patients, 14.9 in 34 hyperthyroid patients, 13.5 in 25 patients with hepatic cirrhosis, and 14.3 in 31 newborns' cord blood serum. The values for the latter four groups were significantly different from normal. The serum 3',5'-T 2 concentration of 7.7 ng/dl in eight subjects in the third trimester of pregnancy did not differ from normal when serum T 4 and T 3 were elevated. Oral administration of 300 μg rT 3 to 9 normal subjects led to an increase in serum 3'5'-T 2 concentration of 45% at 1h. Total fasting in 3 obese subjects was associated with an increase in serum 3',5'-T 2 from 8.6 to 16.3 ng/dl at 6 to 8 days; rT 3 increased similarly, while T 3 decreased and T 4 did not change. Administration of dexamethasone to 4 hyperthyroid patients was associated with nearly parallel increases in serum 3',5'-T 2 and rT 3 and a decrease in T 3 . The 3',5'-T 2 concentrations in amniotic fluids were 15.2 ng/dl at 15 to 20 weeks gestation and 5.8 ng/dl at 33 to 40 weeks. Pronase hydrolysates of 9 normal thyroid glands contained 350 μgT 4 and 0.24 μg 3',5'-T 2 /g wet wt. It was estimated that thyroidal secretion contributes 2 in serum of normal man. The data suggest that 3',5'-T 2 is a normal component of human serum and almost all 3',5'-T 2 in serum derives from extrathyroidal sources

  16. In vivo and ex vivo proton MR spectroscopy of primary and secondary melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Bourne, Roger M.; Stanwell, Peter; Stretch, Jonathan R.; Scolyer, Richard A.; Thompson, John F.; Mountford, Carolyn E.; Lean, Cynthia L

    2005-03-01

    In vivo magnetic resonance (MR) spectroscopy at 1.5T was performed on a large polypoid cutaneous melanoma, and two enlarged lymph nodes containing metastatic melanoma, from three patients. Spectra were acquired in vivo from voxels wholly within the primary tumour or secondary lymph node and were thus uncontaminated by signals from adjacent tissue. Tissue biopsies taken after resection of primary tumours and secondary lymph nodes were examined by 8.5T magnetic resonance spectroscopy (MRS) and the results compared with the in vivo spectra, and with spectra from normal skin and a benign skin lesion. There was good agreement between the dominant features of 1.5T spectra acquired in vivo and 8.5T spectra acquired from resected tissue. However, less intense resonances observed at 8.5T in malignant biopsy tissue were not consistently observed at 1.5T in vivo. In vivo spectra from primary and metastatic melanoma showed high levels of choline metabolites. An intense lactate resonance was also present in the in vivo spectrum of primary melanoma. All 8.5T spectra of biopsies from primary and secondary melanoma showed high levels of choline metabolites and lactate, and additional resonances consistent with elevated levels of taurine, alanine, lysine, and glutamate/glutamine relative to normal and benign tissue. Elevated levels of choline, lactate, taurine, and amino acids appear to be clinically useful markers for identifying the pathology of primary and metastatic melanoma.

  17. Paenibacillus sonchi sp. nov., a nitrogen-fixing species isolated from the rhizosphere of Sonchus oleraceus.

    Science.gov (United States)

    Hong, Yuan-Yuan; Ma, Yu-Chao; Zhou, Yu-Guang; Gao, Fei; Liu, Hong-Can; Chen, San-Feng

    2009-11-01

    A nitrogen-fixing bacterium, designated strain X19-5(T), was isolated from rhizosphere soil of Sonchus oleraceus. Phylogenetic analysis based on a fragment of the nifH gene and the full-length 16S rRNA gene sequence revealed that strain X19-5(T) was a member of the genus Paenibacillus. Strain X19-5(T) showed the highest 16S rRNA gene sequence similarity (98.8 %) with Paenibacillus graminis RSA19(T) and below 97 % similarity with other recognized members of the genus. The level of DNA-DNA relatedness between strain X19-5(T) and P. graminis RSA19(T) was 45.7 %. The DNA G+C content of strain X19-5(T) was 46.8 mol%. The major fatty acids were anteiso-C(15 : 0), C(16 : 0) and iso-C(16 : 0). On the basis of its phenotypic characteristics and the level of DNA-DNA hybridization, strain X19-5(T) is considered to represent a novel species of the genus Paenibacillus, for which the name Paenibacillus sonchi sp. nov. is proposed. The type strain is X19-5(T) (=CCBAU 83901(T)=LMG 24727(T)).

  18. Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection

    International Nuclear Information System (INIS)

    Fernandes, L.M.P.; Antognini, A.; Boucher, M.; Conde, C.A.N.; Huot, O.; Knowles, P.; Kottmann, F.; Ludhova, L.; Mulhauser, F.; Pohl, R.; Schaller, L.A.; Santos, J.M.F. dos; Taqqu, D.; Veloso, J.F.C.A.

    2003-01-01

    The behaviour of large-area avalanche photodiodes for X-rays, visible and vacuum-ultra-violet (VUV) light detection in magnetic fields up to 5 T is described. For X-rays and visible light detection, the photodiode pulse amplitude and energy resolution were unaffected from 0 to 5 T, demonstrating the insensitivity of this type of detector to strong magnetic fields. For VUV light detection, however, the photodiode relative pulse amplitude decreases with increasing magnetic field intensity reaching a reduction of about 24% at 5 T, and the energy resolution degrades noticeably with increasing magnetic field

  19. Tokamak poloidal field systems. Progress report, January 1-December 31, 1979

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1980-05-01

    Work is reported on the development of superconducting tokamak poloidal field systems (TPFS). Progress is discussed on the design of a 20 MJ, 50 kA, 7.5 T superconducting pulsed energy storage coil operated in a 1 to 2 s bipolar mode from +7.5 T to -7.5 T in 1982. Conductor development for the coil is presented. A facility that uses a traction motor energy transfer system to test coils in the 20 to 100 MJ energy range is discussed. Current interrupter development and testing for protection and energy transfer circuits are also presented. The 400 kJ METS coil test preparation is under way

  20. Maize production in the central Kenya highlands using cattle ...

    African Journals Online (AJOL)

    Mo

    effective in the production of maize, compared to singular application of manures (5 t ha-1) and mineral fertilizer alone applied at rates below ...... A Handbook of Methods, 2nd. Edition. ... Manure management in the Kenya highlands: Practices.

  1. Fine 5 Eesti tantsuväljal / Iiris Viirpalu

    Index Scriptorium Estoniae

    Viirpalu, Iiris, 1992-

    2017-01-01

    Nüüdistantsuteatril Fine 5 täitub tänavu 25. tegutsemisaasta. Fine 5 käekirjast. Vestlusest Fine 5 tantsuteatri ja -kooli kauaaegsete kunstiliste juhtide Renee Nõmmiku ja Tiina Olleskiga Eesti tantsukunstist

  2. Degradation of 2,4,5-trichlorophenoxyacetic acid in aqueous solution by 60Co-γ irradiation

    International Nuclear Information System (INIS)

    Liu Yuanxia; Yu Yuan; Bao Huaying

    2010-01-01

    2,4,5-trichlorophenoxyacetic acid(2,4,5-T) is one kind of phenoxy-hydroxy-acid herbicides, also is one kind of Endocrine Disrupting Chemicals. The degradation of 2,4,5-T in aqueous solution by 60 Co-γ irradiation was investigated in the paper. The degradation effect of different influencing factors, such as absorbed dose and irradiation aura, was studied respectively. The degradation products were preliminarily analyzed by High Performance Liquid Chromatography, UV-Vis spectrophotometer and Ion Chromatography. The results showed that 2,4,5-T could be effectively degraded in aqueous solutions by 60 Co-γ irradiation. Meanwhile, the Chloride ion was detected in the solution, whose concentration increased with the growth of absorbed dose. It was found that although both e-aq and ·OH originated from water radiolysis could eliminate 2,4,5-T, the dechlorination effect and the degradation products were different. (authors)

  3. Dislocation unpinning model of acoustic emission from alkali halide ...

    Indian Academy of Sciences (India)

    The present paper reports the dislocation unpinning model of acoustic emis- sion (AE) from ... Acoustic emission; dislocation; alkali halide crystals; plastic deformation. ..... [5] T Nishimura, A Tahara and T Kolama, Jpn. Metal Inst. 64, 339 (2000).

  4. Novel polymorphic microsatellite markers for the helophytic plant ...

    Indian Academy of Sciences (India)

    colonies were amplified using TempliPhi (GE Healthcare,. Buckinghamshire ... value. A ccession no. HM01. F: 5. -. T. GTTGTGCAGAGAGACTGAGG-3. (GA). 17. 161–163. 3 .... Window–based freeware for population genetic analysis. Univer-.

  5. The role of diffusion-weighted MRI: In assessment of response to radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Manal H. Wahba

    2015-03-01

    Conclusion: With the use of a 1.5-T MR scanner, our preliminary results suggest that ADC values may be useful as a non-invasive imaging biomarker for monitoring therapeutic response of prostate cancer to radiotherapy.

  6. Melting of heterogeneous vortex matter: The vortex 'nanoliquid'

    Indian Academy of Sciences (India)

    E ZELDOV2, A SOIBEL3, F de la CRUZ4,CJ van der BEEK5,. M KONCZYKOWSKI5, T ... 2Department of Condensed Matter Physics, Weizmann Institute of Science, Rehovot. 76100, Israel ..... heterogeneous nature of the vortex nanoliquid.

  7. Similaridade genética entre cultivares de cebola de diferentes tipos e origens, baseada em marcadores AFLP Genetic similarity among onion cultivars of different types and origins, based on AFLP markers

    Directory of Open Access Journals (Sweden)

    CAF Santos

    2011-03-01

    Full Text Available Foi estimada a similaridade genética entre cultivares de cebola de diferentes tipos e regiões geográficas, de forma a orientar programas de recursos genéticos e melhoramento da espécie no Nordeste brasileiro. Foram analisadas 41 cultivares, adotando-se para a visualização da similaridade genética o fenograma UPGMA gerado da matriz de distâncias genéticas estimadas pelo coeficiente de Jaccard e baseadas em 146 bandas polimórficas de Pst1 e Mse1 de AFLP. A correlação cofenética foi de 0,91, indicando boa confiabilidade da representação gráfica para a interpretação dos resultados. Foram observados dois grupos principais no fenograma, no ponto de corte de 0,55 de similaridade: 1 grupo formado por cultivares predominantemente brasileiras, com algumas inclusões de cultivares estrangeiras; e 2 grupo formado por três cultivares estrangeiras (Mercedes, Perfect e TEG 502 PRR. Rijnsburger Jumbo e IPA 8 apresentaram a maior similaridade (85%, enquanto Madrugada foi a mais divergente em relação às demais cultivares. As cultivares da série IPA se dividiram em subgrupos no grupo das cultivares brasileiras (IPA 8, IPA 10 e IPA 11; IPA 12, IPA 7, IPA 2 e IPA 6; IPA 3, IPA 4 e IPA 9, indicando haver variabilidade genética a ser explorada entre aquelas situadas em subgrupos distintos. Bola Precoce e BRS Cascata apresentaram a maior similaridade entre as cultivares de origem brasileira. Foi observada similaridade superior a 39%, refletindo a alta variabilidade genética da coleção de cebola estudada. A introdução de novos acessos deve considerar procedências outras que não norte americanas, para aumentar a variabilidade de germoplasma de cebola disponível no Nordeste do Brasil.The genetic similarity among onion cultivars of different origins was evaluated, in order to carry out genetic resources and breeding programs for this species on the Brazilian Northeast. Forty-one onion cultivars were analyzed for 146 polymorphic Pst1/Mse1

  8. Herbage Production, Nutritive Value and Grazing Preference of Diploid and Tetraploid Perennial Ryegrass Cultivars (Lolium perenne L. Producción de Fitomasa, Calidad Nutritiva y Preferencia de Pastoreo de Cultivares Diploides y Tetraploides de Ballica Perenne (Lolium perenne L.

    Directory of Open Access Journals (Sweden)

    Oscar A Balocchi

    2009-09-01

    Full Text Available The objective of this study was to determine, under the soil and climatic conditions of Southern Chile, the effect of the ploidy of perennial ryegrass (Lolium perenne L. cultivars on herbage production, nutritive value, grazing preference and utilization of pasture produced. This study was conducted in southern Chile, Valdivia Province, and was evaluated for 3 years. The tetraploid cultivars used were Quartet (4n, Gwendal (4n, Pastoral (4n and Napoleon (4n. The diploid cultivars were Anita (2n, Jumbo (2n, Aries (2n, and Yatsyn 1 (2n.When the average sward height reached 20 cm, all plots were simultaneously grazed by dairy cows for a period of 24 h. Before and after grazing, sward height, dry matter availability and nutritive value were evaluated. Grazing preference was visually assessed every 5 min for a period of 2.5 h after the afternoon milking. During the 3-year period 20 grazing events were evaluated. A randomized complete block design, with eight cultivars and three replicates, was used. Diploid cultivars showed greater herbage mass accumulation than tetraploid cultivars (P ≤ 0.05. No significant differences were obtained in the annual average crude protein content. Nevertheless, tetraploid cultivars showed a greater D value than diploid cultivars, except during the third year when the difference was not statistically significant. Dairy cows grazed more time on tetraploid cultivars. Considering, additionally, the residual herbage mass after grazing and the percentage of pasture utilization, diploid cultivars were less intensively grazed, suggesting a lower consumption by the cows.El objetivo de este estudio fue determinar, bajo las condiciones edafoclimáticas del sur de Chile, el efecto de la ploidía de cultivares de ballica perenne (Lolium perenne L. sobre el rendimiento de fitomasa, calidad nutricional, preferencia de pastoreo y porcentaje de utilización del forraje producido. El ensayo se realizó en el sur de Chile, provincia de

  9. Spill Assessment Model (SAM) Procedure for Manual Field Calculations.

    Science.gov (United States)

    1980-04-01

    Latlealiy on 5t ValqdmMellRtt ChwoeateetLw , ,’I ,,,,,, I , I.,, 5 t0 Odaeweahali2l r, REVISED 1978 73 watery liqoid Red. blur. green . brow or Gavctine...SpeImia "dagads of Consib~st"-u PreductSm 84 Food cIUI" Cta P.I~ FLAMMABLIE Flariblaok along vapor IOSI t0vl owor 66 Behavor in Fire I, h- , , I

  10. Effect of urea-molasses treatment on chemical composition and in ...

    African Journals Online (AJOL)

    An experiment was conducted to evaluate changes in the chemical composition and in vitro digestibility of urea-molasses treated maize cobs. Maize cob (Zea mays) was treated with fertilizer grade urea and molasses dissolved in water equivalent to 0.5 % (T2), 1.0% (T3), 1.5% (T4) and 2% (T5) (w/v) to which was added ...

  11. Air traffic management system design using satellite based geo-positioning and communications assets

    Science.gov (United States)

    Horkin, Phil

    1995-01-01

    The current FAA and ICAO FANS vision of Air Traffic Management will transition the functions of Communications, Navigation, and Surveillance to satellite based assets in the 21st century. Fundamental to widespread acceptance of this vision is a geo-positioning system that can provide worldwide access with best case differential GPS performance, but without the associated problems. A robust communications capability linking-up aircraft and towers to meet the voice and data requirements is also essential. The current GPS constellation does not provide continuous global coverage with a sufficient number of satellites to meet the precision landing requirements as set by the world community. Periodic loss of the minimum number of satellites in view creates an integrity problem, which prevents GPS from becoming the primary system for navigation. Furthermore, there is reluctance on the part of many countries to depend on assets like GPS and GLONASS which are controlled by military communities. This paper addresses these concerns and provides a system solving the key issues associated with navigation, automatic dependent surveillance, and flexible communications. It contains an independent GPS-like navigation system with 27 satellites providing global coverage with a minimum of six in view at all times. Robust communications is provided by a network of TDMA/FDMA communications payloads contained on these satellites. This network can support simultaneous communications for up to 30,000 links, nearly enough to simultaneously support three times the current global fleet of jumbo air passenger aircraft. All of the required hardware is directly traceable to existing designs.

  12. Fire analyses in central and disposal tunnels by APROS; Keskus- ja loppusijoitustunneleiden palotarkasteluja APROSilla

    Energy Technology Data Exchange (ETDEWEB)

    Peltokorpi, L.; Kukkola, T.; Nieminen, J. [Fortum Power and Heat Oy, Espoo (Finland)

    2012-12-15

    The central tunnels and the disposal tunnels on the north-east disposal area are the target areas of the fire studies. Target is to maintain under pressure in the fire zone in case of a fire. In the central tunnels a fire of a drilling jumbo with moderate fire propagation is used as heat release rate. In the disposal tunnel the heat release rate of a canister transfer and installation vehicle fire received as a result of the pyrolysis analyze as well as an average heat release rate of a van fire are used. Inlet air is to be conducted to the back end of the fire zone and the exhaust is to be lead out from the beginning of the fire zone. The worst location of the fire is in the beginning of the fire zone just below of the exhaust air clap valve. The size of the fire zone does not have big impact on pressure. In all analyzed cases the fire zone remains too long time over pressurized. Inlet air flow of a 30 m{sup 3}/s is too much. The rotation controlled booster blowers will solve the pressure problems of the fire zone in fire cases. The rotation is controlled by the fire zone pressure. The fire of the canister transfer and installation vehicle in the central tunnel will not cause problems. The disposal tunnel fire door should be kept open, if the canister transfer and installation vehicle or the bentonite blocks transfer and installation vehicle is driven into the disposal tunnel. If a fire is caught in the disposal tunnel then the fire zone in the central tunnel is to be closed and the pressure is controlled by the rotation controlled booster blowers. If a personnel car or a van is driven into the disposal tunnel, then fire door of the disposal is to be kept closed against fires in the central tunnel. (orig.)

  13. Role of support services in Jaduguda mine

    International Nuclear Information System (INIS)

    Roy, Pinaki; Bannerjee, S.N.; Srinivasan, M.N.; Radhakrishnan, V.N.; Khanwalkar, S.D.

    1991-01-01

    This paper highlights the role of the supporting services which are divided into two main groups. Group A consists of services rendered by survey, planning, geology and physics sub-groups. The survey sub-group enforces the directional controls of the various lay-outs, the underground geology sub-group establishes the parameters for the development of drives and stop blocks while the physics section supplies the data regarding grade and thickness and exercises the ore quality control. The techniques evolved in giving these supports to the production system is described. Diamond drilling of holes through rock formation have been successfully used for transporting stowing sand and for draining accumulated water in the levels to respective sumps besides its normal use for underground exploration. Group B consists of engineering services. With limited mining machinery in the early sixties, the mechanical engineering services have taken significant strides for servicing today's equipments consisting of drill jumbos, hydro-pneumatic trackless loaders. Alimak raises climbers, diesel locomotives and mechanised ore transfer systems besides servicing the vital area of modern koepe system of friction winding where Jaduguda has already been a fore-runner in the country. Electrical engineering services basically maintain the electrical systems and equipments both permanent and extensions as mining areas progress in depth. Indigenisation of imported equipments and spares for them and modernisation in certain key areas has been attempted successfully over the years. Civil engineering services are mostly confined to strengthening support system for mine tunnels and construction of ore transfer passes for stopping. (author). 3 figs

  14. Performance investigation of ground cooling for the airbus A380 in the United Arab Emirates

    International Nuclear Information System (INIS)

    Aranjo, Brendan Savio; Hughes, Ben Richard; Chaudry, Hassam Nasarullah

    2012-01-01

    A combination of the United Arab Emirates (UAE) climate and the increased size of the super jumbo, Airbus A380, have exceeded the working capacity for current ground cooling techniques. These are evident when the aircraft is being prepared for flight and when in the hanger under maintenance with internal cabin temperatures reported at above 30 °C. The existing system used, delivers air at 11.6 °C after which the cabin temperature is still at a high temperature of 31 °C and unable to cool down due to the temperature rises caused by climate conditions and heat dissipation from the electronics in the cabin. The CFD based temperature profile results highlighted that a decrease in inlet temperature to −18 °C at a constant pressure and mass flow rate is sufficient to provide efficient cooling to the cabin at 22 °C. Boundary conditions are determined to specify a new effective cooling system and resolve the ground cooling issue. - Highlights: ► Computational Fluid Dynamics (CFD) analysis was carried out on the aircraft cabin. ► Existing system delivers air at 11.6 °C. ► Cabin temperature is still at a high temperature of 31 °C. ► The inlet temperature of the air should be −18 °C using the existing system. ► Air is delivered at 6.5 kg/s, to cool the cabin to a comfortable temperature of 22 °C.

  15. Transcription Profiling of Bacillus subtilis Cells Infected with AR9, a Giant Phage Encoding Two Multisubunit RNA Polymerases.

    Science.gov (United States)

    Lavysh, Daria; Sokolova, Maria; Slashcheva, Marina; Förstner, Konrad U; Severinov, Konstantin

    2017-02-14

    Bacteriophage AR9 is a recently sequenced jumbo phage that encodes two multisubunit RNA polymerases. Here we investigated the AR9 transcription strategy and the effect of AR9 infection on the transcription of its host, Bacillus subtilis Analysis of whole-genome transcription revealed early, late, and continuously expressed AR9 genes. Alignment of sequences upstream of the 5' ends of AR9 transcripts revealed consensus sequences that define early and late phage promoters. Continuously expressed AR9 genes have both early and late promoters in front of them. Early AR9 transcription is independent of protein synthesis and must be determined by virion RNA polymerase injected together with viral DNA. During infection, the overall amount of host mRNAs is significantly decreased. Analysis of relative amounts of host transcripts revealed notable differences in the levels of some mRNAs. The physiological significance of up- or downregulation of host genes for AR9 phage infection remains to be established. AR9 infection is significantly affected by rifampin, an inhibitor of host RNA polymerase transcription. The effect is likely caused by the antibiotic-induced killing of host cells, while phage genome transcription is solely performed by viral RNA polymerases. IMPORTANCE Phages regulate the timing of the expression of their own genes to coordinate processes in the infected cell and maximize the release of viral progeny. Phages also alter the levels of host transcripts. Here we present the results of a temporal analysis of the host and viral transcriptomes of Bacillus subtilis infected with a giant phage, AR9. We identify viral promoters recognized by two virus-encoded RNA polymerases that are a unique feature of the phiKZ-related group of phages to which AR9 belongs. Our results set the stage for future analyses of highly unusual RNA polymerases encoded by AR9 and other phiKZ-related phages. Copyright © 2017 Lavysh et al.

  16. Marine Invertebrates: Communities at Risk

    Directory of Open Access Journals (Sweden)

    Jennifer Mather

    2013-06-01

    Full Text Available Our definition of the word ‘animal’ centers on vertebrates, yet 99% of the animals on the planet are invertebrates, about which we know little. In addition, although the Census of Marine Life (COML.org has recently conducted an extensive audit of marine ecosystems, we still do not understand much about the animals of the seas. Surveys of the best-known ecosystems, in which invertebrate populations often play a key role, show that the invertebrate populations are affected by human impact. Coral animals are the foundation of coral reef systems, which are estimated to contain 30% of the species in the ocean. Physical impact and chemical changes on the water severely damage these reefs, and may lead to the removal of these important habitats. Tiny pteropod molluscs live in huge numbers in the polar seas, and their fragile shells are particularly vulnerable to ocean acidification. Their removal would mean that fishes on which we depend would have a hugely diminished food supply. In the North Sea, warming is leading to replacement of colder water copepods by warmer water species which contain less fat. This is having an effect on the birds which eat them, who enrich the otherwise poor land on which they nest. Conversely, the warming of the water and the loss of top predators such as whales and sharks has led to an explosion of the jumbo squid of the Pacific coast of North America. This is positive in the development of a squid fishery, yet negative because the squid eat fish that have been the mainstay of the fishery along that coast. These examples show how invertebrates are key in the oceans, and what might happen when global changes impact them.

  17. Construction features of the exploratory shaft at Yucca Mountain

    International Nuclear Information System (INIS)

    Adair, G.W.; Fiore, J.N.

    1984-01-01

    The Exploratory Shaft (ES) at Yucca Mountain is planned to be constructed during 1985 and 1986 as part of the detailed site characterization for one of three sites which may be selected as candidates for location of a high-level radioactive waste repository. Conventional mining methods will be used for the shaft sinking phase of the ES project. The ES will be comprised of surface support facilities, a 1480-ft-deep circular shaft lined with concrete to a finished inside diameter of 12 ft, lateral excavations and test installations extending up to 200 ft from the shaft, and long lateral borings extending up to 2300 ft from the shaft. The estimated time for sinking the shaft to a total depth of about 1480 ft and completing the lateral excavations and borings is about two years. The major underground development planned for the primary test level at a depth of 1200 ft consists of the equivalent of 1150 ft of 15- by 15-ft drift. The total volume of rock to be removed from the shaft proper and the lateral excavations totals about 1/2 million cubic feet. Construction equipment for the shaft and underground excavation phases consists of conventional mine hoisting equipment, shot hole and rock bolt drilling jumbos, mucking machines, and hauling machines. The desire to maintain relatively uniform and even walls in selected shaft and drift intervals will require that controlled blasting techniques be employed. Certain lateral boring operations associated with tests to be conducted in the underground development may pose some unusual problems or require specialized equipment. One of the operations is boring and lining a 30-in.-diam by 600-ft-long horizontal hole with a boring machine being developed under the direction of Sandia National Laboratories. Another special operation is coring long lateral holes (500 to 2000 ft) with minimum use of liquid circulating fluids. 8 figures

  18. Construction features of the Exploratory Shaft at Yucca Mountain

    International Nuclear Information System (INIS)

    Adair, G.W.; Fiore, J.N.

    1984-01-01

    The Exploratory Shaft (ES) at Yucca Mountain is planned to be constructed during 1985 and 1986 as part of the detailed site characterization for one of three sites which may be selected as candidates for location of a high-level radioactive waste repository. Conventional mining methods will be used for the shaft sinking phase of the ES project. The ES will be comprised of surface support facilities, a 1,480-foot-deep circular shaft lined with concrete to a finished inside diameter of 12 feet, lateral excavations and test installations extending up to 200 feet from the shaft, and long lateral borings extending up to 2,300 feet from the shaft. The estimated time for sinking the shaft to a total depth of about 1,480 feet and completing the lateral excavations and borings is about two years. The major underground development planned for the primary test level at a depth of 1,200 feet consists of the equivalent of 1,150 feet of 15- by 15-foot drift. The total volume of rock to be removed from the shaft proper and the lateral excavations totals about 1/2 million cubic feet. Construction equipment for the shaft and underground excavation phases consists of conventional mine hoisting equipment, shot hole and rock bolt drilling jumbos, mucking machines, and hauling machines. The desire to maintain relatively uniform and even walls in selected shaft and drift intervals will require that controlled blasting techniques be employed. Such techniques generally classified as ''smooth blasting'' are commonly used for excavation in the construction industry

  19. Possibilities of production of smokeless fuel via carbonization of Czech coals

    Energy Technology Data Exchange (ETDEWEB)

    Buchtele, J.; Straka, P. [Inst. of Rock Structure and Mechanics, Prague (Czechoslovakia)

    1995-12-01

    It was consumed 48 -51 % of hard coal (total output 28 - 30 Mt/year) in a long period for the production of coke. It appears to be anomaly in comparison with other coke producers in Europe and in the world, it was predeterminated by {open_quotes}steel conception{close_quotes} of state`s economics. The production of coke reached 10-11 Mt/year in former Czechoslovakia in the period 1970-1990. A considerable quantity 1.2 - 1.7 Mt/year of produced coke was utilized for heating. In comparison, 7-5.4 Mt coke/year was it in Poland for the heating. Al coke production is realized on the basis of Czech hard coals mined in the southern part of Upper Silesian Coal District. The coke production is operated in multi-chamber system with full recovery of chemical products (gas, raw tar, raw benzene, amonium etc.). The future trend of smokeless fuel production in Czech Republic makes for to the non-recovery coke oven, it means to two-product processes (coke + reduction gas, coke + electricity and so on). Jewell--Thompson coke oven (hard coal) and Salem oven (ignites) represent nonrecovery nowadays. The possibility of it`s application in Czech Republic are discussed. Jumbo coking reactor system (European project No. 500 to the Eureka programme) produces primarily metallurgical coke. The strong Clean Air Act suspends the production of smokeless fuel in multi-chamber system also in Czech Republic for the future period 2010-2020.

  20. Impact of straw mulch on populations of onion thrips (Thysanoptera: Thripidae) in onion.

    Science.gov (United States)

    Larentzaki, E; Plate, J; Nault, B A; Shelton, A M

    2008-08-01

    Development of insecticide resistance in onion thrips, Thrips tabaci Lindeman (Thysanoptera: Thripidae), populations in onion (Allium spp.) fields and the incidence of the T. tabaci transmitted Iris yellow spot virus have stimulated interest in evaluating alternative management tactics. Effects of straw mulch applied in commercial onion fields in muck areas of western New York were assessed in 2006 and 2007 as a possible onion thrips management strategy. In trials in which no insecticides were applied for thrips control, straw mulch-treated plots supported significantly lower T. tabaci populations compared with control plots. In both years, the action thresholds of one or three larvae per leaf were reached in straw mulch treatments between 7 and 14 d later than in the control. Ground predatory fauna, as evaluated by pitfall trapping, was not increased by straw mulch in 2006; however, populations of the common predatory thrips Aeolothrips fasciatus (L.) (Thysanoptera: Aeolothripidae) were significantly lower in straw mulch plots in both years. Interference of straw mulch in the pupation and emergence of T. tabaci was investigated in the lab and their emergence was reduced by 54% compared with bare soil. In the field the overall yield of onions was not affected by the straw mulch treatment; however, the presence of jumbo grade onions (>77 mm) was increased in 2006, but not in 2007. These results indicate that populations of T. tabaci adults and larvae can be significantly reduced by the use of straw mulch without compromising overall onion yield. The use of this cultural practice in an onion integrated pest management program seems promising.

  1. Marine invertebrates: communities at risk.

    Science.gov (United States)

    Mather, Jennifer

    2013-06-10

    Our definition of the word 'animal' centers on vertebrates, yet 99% of the animals on the planet are invertebrates, about which we know little. In addition, although the Census of Marine Life (COML.org) has recently conducted an extensive audit of marine ecosystems, we still do not understand much about the animals of the seas. Surveys of the best-known ecosystems, in which invertebrate populations often play a key role, show that the invertebrate populations are affected by human impact. Coral animals are the foundation of coral reef systems, which are estimated to contain 30% of the species in the ocean. Physical impact and chemical changes on the water severely damage these reefs, and may lead to the removal of these important habitats. Tiny pteropod molluscs live in huge numbers in the polar seas, and their fragile shells are particularly vulnerable to ocean acidification. Their removal would mean that fishes on which we depend would have a hugely diminished food supply. In the North Sea, warming is leading to replacement of colder water copepods by warmer water species which contain less fat. This is having an effect on the birds which eat them, who enrich the otherwise poor land on which they nest. Conversely, the warming of the water and the loss of top predators such as whales and sharks has led to an explosion of the jumbo squid of the Pacific coast of North America. This is positive in the development of a squid fishery, yet negative because the squid eat fish that have been the mainstay of the fishery along that coast. These examples show how invertebrates are key in the oceans, and what might happen when global changes impact them.

  2. An unforgettable apple: memory and attention for forbidden objects.

    Science.gov (United States)

    Truong, Grace; Turk, David J; Handy, Todd C

    2013-12-01

    Are we humans drawn to the forbidden? From jumbo-sized soft drinks to illicit substances, the influence of prohibited ownership on subsequent demand has made this question a pressing one. We know that objects that we ourselves own have a heightened psychological saliency, relative to comparable objects that are owned by others, but do these kinds of effects extend from self-owned to "forbidden" objects? To address this question, we developed a modified version of the Turk shopping paradigm in which "purchased" items were assigned to various recipients. Participants sorted everyday objects labeled as "self-owned", "other-owned," and either "forbidden to oneself" (Experiment 1) or "forbidden to everyone" (Experiment 2). Subsequent surprise recognition memory tests revealed that forbidden objects with high (Experiment 1) but not with low (Experiment 2) self-relevance were recognized as well as were self-owned objects, and better than other-owned objects. In a third and final experiment, we used event-related potentials (ERPs) to determine whether self-owned and self-forbidden objects, which showed a common memory advantage, are in fact treated the same at a neurocognitive-affective level. We found that both object types were associated with enhanced cognitive analysis, relative to other-owned objects, as measured by the P300 ERP component. However, we also found that self-forbidden objects uniquely triggered an enhanced response preceding the P300, in an ERP component (the N2) that is sensitive to more rapid, affect-related processing. Our findings thus suggest that, whereas self-forbidden objects share a common cognitive signature with self-owned objects, they are unique in being identified more quickly at a neurocognitive level.

  3. Fire analyses in central and disposal tunnels by APROS

    International Nuclear Information System (INIS)

    Peltokorpi, L.; Kukkola, T.; Nieminen, J.

    2012-12-01

    The central tunnels and the disposal tunnels on the north-east disposal area are the target areas of the fire studies. Target is to maintain under pressure in the fire zone in case of a fire. In the central tunnels a fire of a drilling jumbo with moderate fire propagation is used as heat release rate. In the disposal tunnel the heat release rate of a canister transfer and installation vehicle fire received as a result of the pyrolysis analyze as well as an average heat release rate of a van fire are used. Inlet air is to be conducted to the back end of the fire zone and the exhaust is to be lead out from the beginning of the fire zone. The worst location of the fire is in the beginning of the fire zone just below of the exhaust air clap valve. The size of the fire zone does not have big impact on pressure. In all analyzed cases the fire zone remains too long time over pressurized. Inlet air flow of a 30 m 3 /s is too much. The rotation controlled booster blowers will solve the pressure problems of the fire zone in fire cases. The rotation is controlled by the fire zone pressure. The fire of the canister transfer and installation vehicle in the central tunnel will not cause problems. The disposal tunnel fire door should be kept open, if the canister transfer and installation vehicle or the bentonite blocks transfer and installation vehicle is driven into the disposal tunnel. If a fire is caught in the disposal tunnel then the fire zone in the central tunnel is to be closed and the pressure is controlled by the rotation controlled booster blowers. If a personnel car or a van is driven into the disposal tunnel, then fire door of the disposal is to be kept closed against fires in the central tunnel. (orig.)

  4. MARKETING ANALYZE OF JERUK SIAM (CITRUS NOBILUS LOURVAR IN DESA PULAU JAMBU KECAMATAN KUOK KABUPATEN KAMPAR

    Directory of Open Access Journals (Sweden)

    Gita Dewanti

    2015-08-01

    Full Text Available ABSTRACT The marketing of Jeruk Siam principally is about the distribution of the fruits from the farmers to the consumers. This research aims ti analyze: the marketing function, marketing channels, cost, margin, profit, marketing efficiency, and the problem that faced by the marketing institution of Jeruk Siam in Desa Pulau Jambu Kecamatan Kuok Kabupaten Kampar. This research uses the survey method and taking sample of the farmers by the census with the criteria, has minimal 1 hectare of firm land and the age of the plant is about 3-4 years. The sample determining of the marketing institution uses the snow ball sampling method by following the marketing channels. In this reseacrh there are three channels. Channel 1 is the distribution from the farmer to Swalayan Jumbo Mart (super grade, grade A, grade B, channel 2 is the distribution from the farmers-collector-retailer (grade B, grade C, usual grade, channel 3 is the distribution from the farmers to the retailres. The marketing function those are influence to the farmers are exchange function and marketing facility function. The result of the research shows the efficient channel. Seen from the efficiency, channel 3 has 0,93%. Profit, channel 2 grade C has Rp. 1.290,21/kg. Marketing cost, channel 3 has Rp. 93,344/kg. Margin, channel 1 Super grade has Rp. 1.750/kg, and the farmer’s share, channel 3 has 95,19%. The problem of the farmers are the extreme weather, there is no irigation, anda plant disease, while the problems of the marketing institution is the endurance of the fruits for distributing to the far place.

  5. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, Elmar M.; Thomas, John; Paulson, Erik K. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Dale, Brian M. [Siemens Medical Solutions, Cary, NC (United States)

    2006-10-15

    To evaluate whether clips from prior cholecystectomy impair image quality during magnetic resonance cholangiography (MRC) at 3 Tesla (T) compared with 1.5 T, surgical clips were embedded in a gel phantom and positioned at predefined distances from a fluid-filled tube designed to simulate the bile duct. The maximum clip distance was noted where susceptibility artifacts obscured the fluid-filled tube at 1.5 T and 3 T. Susceptibility artifact size was calculated for each sequence within each magnet class. In vivo analysis included 42 patients postcholecystectomy who underwent MRC at either 1.5 T or 3 T. In vitro, mean area of susceptibility artifacts was 104 mm{sup 2} on 3-T and 75 mm{sup 2} on 1.5-T MR imaging (MRI). While surgical clips within a 2-mm range impaired visualization of the fluid-filled tube on 1.5-T MRI, this range increased to 4 mm on 3-T MRI. In vivo, MRC image quality was impaired by susceptibility artifacts in three of 21 cases at 3 T and in two of 21 cases at 1.5 T. Overall, biliary pseudo-obstructions due to susceptibility artifacts from cholecystectomy surgical clips were not substantially more common on 3-T MRC in clinical practice, and patients with a history of prior cholecystectomy should not be excluded from a 3-T MRC. (orig.)

  6. High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing's disease

    Energy Technology Data Exchange (ETDEWEB)

    Rotte, Alexandra A.J. de; Groenewegen, Amy; Rutgers, Dik R.; Witkamp, Theo; Luijten, Peter R.; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Zelissen, Pierre M.J. [University Medical Center Utrecht, Department of Internal Medicine (Section of Endocrinology), Utrecht (Netherlands); Meijer, F.J.A. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Lindert, Erik J. van [Radboud University Medical Center, Department of Neurosurgery, Nijmegen (Netherlands); Hermus, Ad [Radboud University Medical Center, Department of Internal Medicine (Section of Endocrinology), Nijmegen (Netherlands)

    2016-01-15

    To evaluate the detection of pituitary lesions at 7.0 T compared to 1.5 T MRI in 16 patients with clinically and biochemically proven Cushing's disease. In seven patients, no lesion was detected on the initial 1.5 T MRI, and in nine patients it was uncertain whether there was a lesion. Firstly, two readers assessed both 1.5 T and 7.0 T MRI examinations unpaired in a random order for the presence of lesions. Consensus reading with a third neuroradiologist was used to define final lesions in all MRIs. Secondly, surgical outcome was evaluated. A comparison was made between the lesions visualized with MRI and the lesions found during surgery in 9/16 patients. The interobserver agreement for lesion detection was good at 1.5 T MRI (κ = 0.69) and 7.0 T MRI (κ = 0.62). In five patients, both the 1.5 T and 7.0 T MRI enabled visualization of a lesion on the correct side of the pituitary gland. In three patients, 7.0 T MRI detected a lesion on the correct side of the pituitary gland, while no lesion was visible at 1.5 T MRI. The interobserver agreement of image assessment for 7.0 T MRI in patients with Cushing's disease was good, and lesions were detected more accurately with 7.0 T MRI. (orig.)

  7. Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla - a pilot study

    International Nuclear Information System (INIS)

    Knobelsdorff-Brenkenhoff, Florian von; Schulz-Menger, Jeanette; Frauenrath, Tobias; Hezel, Fabian; Prothmann, Marcel; Dieringer, Matthias A.; Niendorf, Thoralf; Renz, Wolfgang; Kretschel, Kerstin

    2010-01-01

    Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. (orig.)

  8. High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing's disease

    International Nuclear Information System (INIS)

    Rotte, Alexandra A.J. de; Groenewegen, Amy; Rutgers, Dik R.; Witkamp, Theo; Luijten, Peter R.; Hendrikse, Jeroen; Zelissen, Pierre M.J.; Meijer, F.J.A.; Lindert, Erik J. van; Hermus, Ad

    2016-01-01

    To evaluate the detection of pituitary lesions at 7.0 T compared to 1.5 T MRI in 16 patients with clinically and biochemically proven Cushing's disease. In seven patients, no lesion was detected on the initial 1.5 T MRI, and in nine patients it was uncertain whether there was a lesion. Firstly, two readers assessed both 1.5 T and 7.0 T MRI examinations unpaired in a random order for the presence of lesions. Consensus reading with a third neuroradiologist was used to define final lesions in all MRIs. Secondly, surgical outcome was evaluated. A comparison was made between the lesions visualized with MRI and the lesions found during surgery in 9/16 patients. The interobserver agreement for lesion detection was good at 1.5 T MRI (κ = 0.69) and 7.0 T MRI (κ = 0.62). In five patients, both the 1.5 T and 7.0 T MRI enabled visualization of a lesion on the correct side of the pituitary gland. In three patients, 7.0 T MRI detected a lesion on the correct side of the pituitary gland, while no lesion was visible at 1.5 T MRI. The interobserver agreement of image assessment for 7.0 T MRI in patients with Cushing's disease was good, and lesions were detected more accurately with 7.0 T MRI. (orig.)

  9. Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Nakamura, Yuko; Higaki, Toru; Akiyama, Yuji; Fukumoto, Wataru; Kajiwara, Kenji; Kaichi, Yoko; Honda, Yukiko; Komoto, Daisuke; Tatsugami, Fuminari; Iida, Makoto; Ohmoto, Toshifumi; Date, Shuji; Awai, Kazuo

    2016-01-01

    To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm 2 ) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm 2 , TE 70 ms; b-value 0 and 600 s/mm 2 , TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm 2 at 1.5T and 3T as “o-1.5T-1000” and “o-3T-1000”. c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm 2 . c-DWI with b = 1000 and 1500 s/mm 2 were defined as “c-1000” and “c-1500”. Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm 2 on 1.5T- and 3T DWIs. Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm 2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm 2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs

  10. Deinococcus hibisci sp. nov., isolated from rhizosphere of Hibiscus syriacus L. (mugunghwa flower).

    Science.gov (United States)

    Moya, Gabriela; Yan, Zheng-Fei; Chu, Dong-Hun; Won, KyungHwa; Yang, Jung-Eun; Wang, Qi-Jun; Kook, Moo-Chang; Yi, Tae-Hoo

    2018-01-01

    A Gram-stain-positive, pink-pigmented, coccus-shaped, strictly aerobic, non-motile bacterium, strain THG-AG1.5 T , was isolated from rhizosphere of Hibiscus syriacus L. (Mugunghwa flower) located in Kyung Hee University, Yongin, Gyeonggi, Republic of Korea. The isolated strain grew optimally at 25-30 °C, at pH 6.0-7.5 and in the presence of additional 0-1.5 % (w/v) NaCl. Strain THG-AG1.5 T exhibited tolerance to UV radiation (>1500 J m -2 ) and to gamma radiation (>12 kGy). Based on 16S rRNA gene sequence comparisons, strain THG-AG1.5 T was closely related to Deinococcus daejeonensis MJ27 T (98.03 %), Deinococcus radiotolerans C1 T (97.61 %) and Deinococcus grandis DSM 3963 T (97.32 %). The genomic DNA G+C content of strain THG-AG1.5 T was 74.8 mol%. The DNA-DNA hybridization values between strain THG-AG1.5 T and its closest phylogenetically neighbours were below 63.0 %. The peptidoglycan amino acids were alanine, valine, glutamic acid, glycine, ornithine, lysine and aspartic acid. Strain THG-AG1.5 T contained ribose, mannose and glucose as whole-cell-wall sugars and menaquinone-8 (MK-8) as the only isoprenoid quinone. The major component in the polyamine pattern was spermidine. The major polar lipids of strain THG-AG1.5 T were a phosphoglycolipid, six unidentified glycolipids and an unidentified aminophospholipid. The major fatty acids were identified as iso-C15 : 0, C15 : 1ω6c, C16 : 0, iso-C17 : 0, C17 : 0, C18 : 0 and summed feature 3. On the basis of our polyphasic taxonomy study, strain THG-AG1.5 T represents a novel species within the genus Deinococcus, for which the name Deinococcushibisci sp. nov. is proposed. The type strain is THG-AG1.5 T (=KACC 18850 T =CCTCC AB 2016078 T ).

  11. Validation of in vivo 2D displacements from spiral cine DENSE at 3T.

    Science.gov (United States)

    Wehner, Gregory J; Suever, Jonathan D; Haggerty, Christopher M; Jing, Linyuan; Powell, David K; Hamlet, Sean M; Grabau, Jonathan D; Mojsejenko, Walter Dimitri; Zhong, Xiaodong; Epstein, Frederick H; Fornwalt, Brandon K

    2015-01-30

    Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the magnetic resonance signal. Due to the stimulated echo, the signal is inherently low and fades through the cardiac cycle. To compensate, a spiral acquisition has been used at 1.5T. This spiral sequence has not been validated at 3T, where the increased signal would be valuable, but field inhomogeneities may result in measurement errors. We hypothesized that spiral cine DENSE is valid at 3T and tested this hypothesis by measuring displacement errors at both 1.5T and 3T in vivo. Two-dimensional spiral cine DENSE and tagged imaging of the left ventricle were performed on ten healthy subjects at 3T and six healthy subjects at 1.5T. Intersection points were identified on tagged images near end-systole. Displacements from the DENSE images were used to project those points back to their origins. The deviation from a perfect grid was used as a measure of accuracy and quantified as root-mean-squared error. This measure was compared between 3T and 1.5T with the Wilcoxon rank sum test. Inter-observer variability of strains and torsion quantified by DENSE and agreement between DENSE and harmonic phase (HARP) were assessed by Bland-Altman analyses. The signal to noise ratio (SNR) at each cardiac phase was compared between 3T and 1.5T with the Wilcoxon rank sum test. The displacement accuracy of spiral cine DENSE was not different between 3T and 1.5T (1.2 ± 0.3 mm and 1.2 ± 0.4 mm, respectively). Both values were lower than the DENSE pixel spacing of 2.8 mm. There were no substantial differences in inter-observer variability of DENSE or agreement of DENSE and HARP between 3T and 1.5T. Relative to 1.5T, the SNR at 3T was greater by a factor of 1.4 ± 0.3. The spiral cine DENSE acquisition that has been used at 1.5T to measure cardiac displacements can be applied at 3T with equivalent accuracy. The inter-observer variability and agreement of DENSE-derived peak strains and

  12. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H.; Gieseke, Juergen; Bastian, Patrick J.; Schmitz, Bettina; Mueller, Stefan C.

    2008-01-01

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests. Dynamic

  13. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Best (Netherlands); Bastian, Patrick J. [University of Munich, Department of Urology, Munich (Germany); Schmitz, Bettina; Mueller, Stefan C. [University of Bonn, Department of Urology, Bonn (Germany)

    2008-11-15

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests

  14. Effect of specimen size on the fracture toughness of Type 304 stainless steel. Interim report

    International Nuclear Information System (INIS)

    Mills, W.J.

    1982-02-01

    The effect of specimen size on the elastic-plastic fracture toughness behavior of Type 304 stainless steel was characterized by the multiple-specimen J-R curve technique at 427 0 C. Fracture tests were performed on five compact specimen sizes: 2.5T (thickness = 63.5 mm), 2.5T (thickness = 14.7 mm), 1T (thickness = 25.4 mm), 1T (thickness = 14.7 mm), and 0.577 (thickness = 14.7 mm). In comparison with the 63.5-mm thick 2.5T specimen results, the smaller specimens exhibited higher J/sub Ic values and lower R-curve slopes (dJ/da). However, the differences in J/sub Ic/ and dJ/da were not statistically significant for the 2.5T and 1T specimens, which suggests that size effects for 1T and larger specimens are relatively small or nonexistant. On the other hand, there was a statistical difference between the 0.577T and 2.5T J/sub Ic/ values

  15. The effects of MRI on mouse embryos during fetal stage

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takashi; Sakazaki, Takahiko; Itokawa, Yuka [Suzuka University of Medical Science, Koriyama (Japan)] (and others)

    2006-06-15

    The effects of Magnetic Resonance Imaging (MRI) on mouse embryos at the early stage of organogenesis were investigated. Pregnant ICR mice were exposed on day 8 of gestation to MRI at 0.5 T for 0.5 hour to 3 hours. The mortality rates of embryos or fetuses, the incidence of external malformations, fetal body weight and sex ratio were observed at day 18 of gestation. A significant increase in embryonic mortality was observed after exposure to either 0.5 T MRI for 0.5 hour or 2 hours. However, the exposure to MRI for 1 hour or 3 hours did not induce any significant increase in embryonic mortality when compared with control. External malformations such as exencephaly, cleft palate and anomalies of tail were observed in all experimental groups exposed to each MRI. A statistically significant increase of external malformations was observed in all groups treated with 0.5 T MRI for 0.5 hour and 3 hours. The incidence of external malformations in the mice group exposed to 0.5 T MRI for 0.5-hour was found to be higher than those of mice group exposed to 0.5 T MRI for 2 hours. The effects of MRI on the external malformations might not to be dose-dependent. There was no statistically significant difference in fetal body weight and sex ratio among each MRI exposure groups.

  16. Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils

    International Nuclear Information System (INIS)

    Schoth, F.; Kraemer, N.; Niendorf, T.; Hohl, C.; Gunther, R.W.; Krombach, G.A.

    2008-01-01

    We examined to what degree the visualization of anatomic structures in the human knee is improved using 3.0-T magnetic resonance imaging (MRI) and many element RF receive coils as compared to 1.5 T. We imaged 20 knees at 1.5 and 3.0 T using T2-weighted STIR, T2-weighted gradient echo, T1-weighted spin-echo, true-FISP and T2-weighted fast spin echo techniques in conjunction with 32-element RF coil arrays. The 3.0-T examination was considerably faster than its 1.5-T counterpart. A superior subjective visibility at 3.0 T vs 1.5 T was found in 27 of 50 evaluated structures (meniscus, ligaments) with the exception of true-FISP techniques. The 3.0-T examination provided a better visibility (evaluated by blinded consensus-reading by two radiologists) of small structures such as the ligamentum transversum genu. Also, cartilage was better delineated at 3.0 T. A 23% increased average signal-to-noise ratio as assessed using a temporal filter was observed at 3.0 T as compared to 1.5 T. At 3.0 T, imaging of the human knee is faster and results in a subjective visibility of anatomic structures that is superior to and competitive with 1.5 T. (orig.)

  17. Tokamak poloidal field systems. Progress report, January 1-December 31, 1980

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1981-03-01

    Work is reported on the development of superconducting tokamak poloidal field system (TPFS) program. Progress is discussed on the design of the 20 MJ, 50 kA, 7.5 T superconducting pulsed energy storage coil to be operated in a bipolar mode from +7.5 T to -7.5 T in an energy transfer period of 1.5 to 5 s in 1982 followed by extensive cyclic testing. The facility to conduct the tests uses a traction motor energy transfer system and a nonconducting dewar. Status of the hardware development for the TPFS program is presented. Current interrupter development and testing for protection and energy transfer circuits are also presented. The 400 kJ METS coil test results are given

  18. Effect of plasma current breakaway on the operating stability of the superconducting coil of the toroidal magnetic field in the T-10M installation

    International Nuclear Information System (INIS)

    Kostenko, A.I.; Kravchenko, M.Yu.; Monoszon, N.A.; Trokhachev, G.V.

    1979-01-01

    The method and calculation results of stability of a superconducting coil of the toroidal magnetic field in the T-10M installation to plasma current breakaway are presented. The calculations were performed for two values of the magnetic field induction in the centre of the plasma cross section: 3.5 and 5 T. The calculation of energy losses and heating of the superconducting coil was performed assuming the plasma current in case of breakaway decreases to zero with an infinite rate, so that the estimations obtained are maxiaum. It is shown that in case of 3.5 T induction the superconducting coil exhibits resistance to plasma current breakaways, and in case of 5 T it is necessary to use electromagnetic screening to provide stability

  19. Peer Evaluation of Master Programs: Closing the Quality Circle of the CDIO Approach?

    DEFF Research Database (Denmark)

    Hussmann, Peter Munkebo; Bisi, Anita; Malmqvist, Johan

    2012-01-01

    programs within their field at another N5T institution. The article describes the quality enhancement tool in detail, its contribution to the development of the involved programs, and how international peer evaluation can contribute to closing the quality circle. Finally, it assesses the value......A quality assurance project was conducted within the framework of the Nordic Five Tech Alliance (N5T), a strategic alliance of the five leading technical universities in Denmark, Finland, Norway, and Sweden. The project concerned the development of a common quality enhancement tool for conducting...... peer evaluations of educational programs to enable their further development and close the quality circle. In addition, the project will contribute to the consolidation of the N5T alliance by facilitating contacts between faculty members and providing them with an in-depth knowledge of the study...

  20. Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator

    Science.gov (United States)

    Bol, G. H.; Hissoiny, S.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2012-03-01

    The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In this paper, a fast IMRT optimization system is described which combines a GPU-based Monte Carlo dose calculation engine for online beamlet generation and a fast inverse dose optimization algorithm. Tightly conformal IMRT plans are generated for four phantom cases and two clinical cases (cervix and kidney) in the presence of the magnetic fields of 0 and 1.5 T. We show that for the presented cases the beamlet generation and optimization routines are fast enough for online IMRT planning. Furthermore, there is no influence of the magnetic field on plan quality and complexity, and equal optimization constraints at 0 and 1.5 T lead to almost identical dose distributions.

  1. VISARTTM superconducting MRI system

    International Nuclear Information System (INIS)

    Usui, Yoshiyuki; Goro, Takehiko; Yamagata, Hitoshi.

    1995-01-01

    We have developed VISART TM , a 1.5 T high-field magnetic resonance imaging (MRI) system based on technology developed for both the FLEXART TM (0.5T) and MRT-200/GP (1.5T) systems as the first and second products, respectively, of a new series of MRI systems. VISART TM is a newly coined word combining VISion and state-of-the-ART. A higher power gradient system and new high-speed imaging techniques have been developed to meet the market demand for higher resolution images and shorter scan times. The product concepts of VISART TM are high image quality, high patient throughput, flexible clinical application, and ease of use, all of which are essential features for an MRI system in the high-field MRI market segment. (author)

  2. Biogas production from brewery spent grain enhanced by bioaugmentation with hydrolytic anaerobic bacteria.

    Science.gov (United States)

    Čater, Maša; Fanedl, Lijana; Malovrh, Špela; Marinšek Logar, Romana

    2015-06-01

    Lignocellulosic substrates are widely available but not easily applied in biogas production due to their poor anaerobic degradation. The effect of bioaugmentation by anaerobic hydrolytic bacteria on biogas production was determined by the biochemical methane potential assay. Microbial biomass from full scale upflow anaerobic sludge blanket reactor treating brewery wastewater was a source of active microorganisms and brewery spent grain a model lignocellulosic substrate. Ruminococcus flavefaciens 007C, Pseudobutyrivibrio xylanivorans Mz5(T), Fibrobacter succinogenes S85 and Clostridium cellulovorans as pure and mixed cultures were used to enhance the lignocellulose degradation and elevate the biogas production. P. xylanivorans Mz5(T) was the most successful in elevating methane production (+17.8%), followed by the coculture of P. xylanivorans Mz5(T) and F. succinogenes S85 (+6.9%) and the coculture of C. cellulovorans and F. succinogenes S85 (+4.9%). Changes in microbial community structure were detected by fingerprinting techniques. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Nonomuraea zeae sp. nov., isolated from the rhizosphere of corn (Zea mays L.).

    Science.gov (United States)

    Shen, Yue; Jia, Feiyu; Liu, Chongxi; Li, Jiansong; Guo, Siyu; Zhou, Shuyu; Wang, Xiangjing; Xiang, Wensheng

    2016-06-01

    A novel actinobacterium, designated strain NEAU-ND5T, was isolated from the rhizosphere of corn (Zea mays L.) collected in Heilongjiang Province, north-east China, and characterized using a polyphasic approach. 16S rRNA gene sequence analysis showed that strain NEAU-ND5T was a member of the genus Nonomuraea, with highest sequence similarities to Nonomuraea jabiensis A4036T (98.29 %), Nonomuraea rosea GW12687T (98.25 %), Nonomuraea candida HMC10T (98.22 %), Nonomuraea rhizophila YIM 67092T (98.04 %) and Nonomuraea kuesteri NRRL B-24325T (98.04 %). Similarities to other type strains of the genus Nonomuraea were lower than 98 %. Morphological and chemotaxonomic properties of strain NEAU-ND5T were also consistent with the description of the genus Nonomuraea. The cell wall contained meso-diaminopimelic acid and the whole-cell sugars were glucose, ribose and madurose. The phospholipid profile consisted of diphosphatidylglycerol, phosphatidylmonomethylethanolamine, phosphatidylethanolamine, hydroxy-phosphatidylmonomethylethanolamine, hydroxy-phosphatidylethanolamine, phosphatidylinositol and phosphatidylinositol mannoside. The major menaquinones were MK-9(H4), MK-9(H2) and MK-9(H0). The predominant cellular fatty acids were iso-C16:0 and 10-methyl C17:0. A combination of DNA-DNA hybridization results and some phenotypic characteristics demonstrated that strain NEAU-ND5T was clearly distinguished from its closely related Nonomuraea species. Consequently, it is concluded that strain NEAU-ND5T represents a novel species of the genus Nonomuraea, for which the name Nonomuraea zeae sp. nov. is proposed. The type strain is NEAU-ND5T (=CGMCC 4.7280T=DSM 100528T).

  4. Can Images Obtained With High Field Strength Magnetic Resonance Imaging Reduce Contouring Variability of the Prostate?

    International Nuclear Information System (INIS)

    Usmani, Nawaid; Sloboda, Ron; Kamal, Wafa; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Danielson, Brita; Murtha, Albert; Amanie, John; Monajemi, Tara

    2011-01-01

    Purpose: The objective of this study is to determine whether there is less contouring variability of the prostate using higher-strength magnetic resonance images (MRI) compared with standard MRI and computed tomography (CT). Methods and Materials: Forty patients treated with prostate brachytherapy were accrued to a prospective study that included the acquisition of 1.5-T MR and CT images at specified time points. A subset of 10 patients had additional 3.0-T MR images acquired at the same time as their 1.5-T MR scans. Images from each of these patients were contoured by 5 radiation oncologists, with a random subset of patients repeated to quantify intraobserver contouring variability. To minimize bias in contouring the prostate, the image sets were placed in folders in a random order with all identifiers removed from the images. Results: Although there was less interobserver contouring variability in the overall prostate volumes in 1.5-T MRI compared with 3.0-T MRI (p < 0.01), there was no significant differences in contouring variability in the different regions of the prostate between 1.5-T MRI and 3.0-T MRI. MRI demonstrated significantly less interobserver contouring variability in both 1.5-T and 3.0-T compared with CT in overall prostate volumes (p < 0.01, p = 0.01), with the greatest benefits being appreciated in the base of the prostate. Overall, there was less intraobserver contouring variability than interobserver contouring variability for all of the measurements analyzed. Conclusions: Use of 3.0-T MRI does not demonstrate a significant improvement in contouring variability compared with 1.5-T MRI, although both magnetic strengths demonstrated less contouring variability compared with CT.

  5. Toward imaging the body at 10.5 tesla.

    Science.gov (United States)

    Ertürk, M Arcan; Wu, Xiaoping; Eryaman, Yiğitcan; Van de Moortele, Pierre-François; Auerbach, Edward J; Lagore, Russell L; DelaBarre, Lance; Vaughan, J Thomas; Uğurbil, Kâmil; Adriany, Gregor; Metzger, Gregory J

    2017-01-01

    To explore the potential of performing body imaging at 10.5 Tesla (T) compared with 7.0T through evaluating the transmit/receive performance of similarly configured dipole antenna arrays. Fractionated dipole antenna elements for 10.5T body imaging were designed and evaluated using numerical simulations. Transmit performance of antenna arrays inside the prostate, kidneys and heart were investigated and compared with those at 7.0T using both phase-only radiofrequency (RF) shimming and multi-spoke pulses. Signal-to-noise ratio (SNR) comparisons were also performed. A 10-channel antenna array was constructed to image the abdomen of a swine at 10.5T. Numerical methods were validated with phantom studies at both field strengths. Similar power efficiencies were observed inside target organs with phase-only shimming, but RF nonuniformity was significantly higher at 10.5T. Spokes RF pulses allowed similar transmit performance with accompanying local specific absorption rate increases of 25-90% compared with 7.0T. Relative SNR gains inside the target anatomies were calculated to be >two-fold higher at 10.5T, and 2.2-fold SNR gain was measured in a phantom. Gradient echo and fast spin echo imaging demonstrated the feasibility of body imaging at 10.5T with the designed array. While comparable power efficiencies can be achieved using dipole antenna arrays with static shimming at 10.5T; increasing RF nonuniformities underscore the need for efficient, robust, and safe parallel transmission methods. Magn Reson Med 77:434-443, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Mechanisms of Recovering Low Cycle Fatigue Damage in Incoloy 901.

    Science.gov (United States)

    1979-01-01

    ZAP. 0665 0374 19A% DATA : 19AE MPS 15 0666 2375 F2e4 JMP .IDF r e667 e376 9 110 LSI ZAP 668 e377 E2?E LOX F,12 ASSURE X- PEG !0SITIVE FOR LSI 0669 0378...NC(MC) 0( 3350 PRIN4T 22,N4TDELTELC(M),DLTPLC(MC,SIGC(MC)o , 03360 A~1~𔃾C..,TP(M.T~4l~lC) -003370 230 22 VORMAT (12, IT1,F6.5,T2,F6.5,T30,F7.2,T42

  7. Structural analysis and unique molecular recognition properties of a Bauhinia forficata lectin that inhibits cancer cell growth.

    Science.gov (United States)

    Lubkowski, Jacek; Durbin, Sarah V; Silva, Mariana C C; Farnsworth, David; Gildersleeve, Jeffrey C; Oliva, Maria Luiza V; Wlodawer, Alexander

    2017-02-01

    Lectins have been used at length for basic research and clinical applications. New insights into the molecular recognition properties enhance our basic understanding of carbohydrate-protein interactions and aid in the design/development of new lectins. In this study, we used a combination of cell-based assays, glycan microarrays, and X-ray crystallography to evaluate the structure and function of the recombinant Bauhinia forficata lectin (BfL). The lectin was shown to be cytostatic for several cancer cell lines included in the NCI-60 panel; in particular, it inhibited growth of melanoma cancer cells (LOX IMVI) by over 95%. BfL is dimeric in solution and highly specific for binding of oligosaccharides and glycopeptides with terminal N-acetylgalactosamine (GalNAc). BfL was found to have especially strong binding (apparent K d  = 0.5-1.0 nm) to the tumor-associated Tn antigen. High-resolution crystal structures were determined for the ligand-free lectin, as well as for its complexes with three Tn glycopeptides, globotetraose, and the blood group A antigen. Extensive analysis of the eight crystal structures and comparison to structures of related lectins revealed several unique features of GalNAc recognition. Of special note, the carboxylate group of Glu126, lining the glycan-binding pocket, forms H-bonds with both the N-acetyl of GalNAc and the peptide amido group of Tn antigens. Stabilization provided by Glu126 is described here for the first time for any GalNAc-specific lectin. Taken together, the results provide new insights into the molecular recognition of carbohydrates and provide a structural understanding that will enable rational engineering of BfL for a variety of applications. Structural data are available in the PDB under the accession numbers 5T50, 5T52, 5T55, 5T54, 5T5L, 5T5J, 5T5P, and 5T5O. © 2016 Federation of European Biochemical Societies.

  8. Design and results of testing the SHF-generator magnetic system of the T-15 device

    International Nuclear Information System (INIS)

    Borisov, V.D.; Koretskij, A.Yu.; Kostenko, A.I.; Monoszon, N.A.; Ostroumov, Yu.N.; Suvorov, M.M.; Trokhachev, G.V.; Churakov, G.F.; Shmal'ko, G.I.; Yakubovskij, V.G.

    1984-01-01

    Design and engineering solutions accepted in the development of the 5T superconducting solenoid of the auxillary heating SHF-generator for the T-15 tokamak are presented. A superconducting coil generates an axially symmetric field with a definite distribution along the SHF-generator gyrocon axis. Limited sizes, high accuracy of coincidence of geometric and magnetic axes, and possibility of operation with different gyrocons are the main peculiarities of the developed cryostat. The required magnetic field of 5T was attained after some training. Heat input at 4.5 K corresponds to the rated value of 2.5 W. Test results for solenoid functional models are presented

  9. Somatic embryogenesis in Malaysian cultivars of sweet potato (Ipomoea batatas L.).

    OpenAIRE

    De Silva, Angela Ee

    2017-01-01

    Three Malaysian sweet potato cultivars, namely Ipomoea batatas (L.) cv. Gendut, Jalomas and Telong, were investigated for their abilities to produce somatic embryos. Shoot meristems were used as the starting materials and cultured on Murashige and Skoog basal media (Murashige and Skoog, 1962) in the presence of auxin 2,4-dichlorophenoxyacetic acid (2,4-D) or 2,4,5-trichlorophenoxyacetic acid (2,4,5-T). Auxin 2,4,5-T at 5 µM was most effective for the initiation of primary embryogenic formati...

  10. New technology for fabrication of multifilament NbTi composite

    International Nuclear Information System (INIS)

    Yang, Y.K.; Ma, W.M.; Peng, W.N.

    1988-01-01

    Explosive bonding-rolling-drawing process has been developed to produce NbTi multifilamentary superconductors. Multifilamentary wires of 0.5mm in diameter and 2.5km in length with 199 filaments of 25μm in dia. have been produced using this process. The critical current density (Jc) is 1.94x10 5 A/cm 2 at 4.2K and 5T for short samples and 4.9x10 4 A/cm 2 and 4.2/K and 8.5T for the magnet have been reached

  11. A Comparison between Gadofosveset Trisodium and Gadobenate Dimeglumine for Steady State MRA of the Thoracic Vasculature

    OpenAIRE

    Camren, G. Paul; Wilson, Gregory J.; Bamra, Vikram R.; Nguyen, Khahn Q.; Hippe, Daniel S.; Maki, Jeffrey H.

    2014-01-01

    Purpose. Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA) of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR) and vessel edge sharpness (ES) as markers of image quality. Materials and Methods. IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ECG-triggered coronal IR-TFE at 1.5T approximately 3-4 minutes following 10 or 15 mL gadofosveset or...

  12. X-Ray diffraction on rare earth-3d Laves phase compound ErCo2 in magnetic field

    International Nuclear Information System (INIS)

    Yagasaki, Katsuma; Notsu, Shiko; Takaesu, Yoshinao; Nakama, Takao; Sakai, Eijiro; Koyama, Keiichi; Watanabe, Kazuo; Burkov, Alexander T.

    2006-01-01

    X-Ray powder diffraction method is used to investigate the effect of magnetic ordering and external magnetic field on crystal structure of Laves phase intermetallic compound ErCo 2 . The diffraction patterns were recorded at temperatures from 300K down to 8.5K in magnetic field up to 5T. Distortion of the room-temperature cubic structure was found in magnetically ordered state below 32K. The symmetry at low temperature is rhombohedral in agreement with literature results, or lower symmetry than it. However the symmetry of the unit cell increases to cubic in external magnetic field of 5T

  13. Diffusion tensor MRI of the kidney at 3.0 and 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kido, Aki; Kataoka, Masako; Yamamoto, Akira (Dept. of Diagnostic Imaging and Nuclear Medicine, Kyoto Univ., Kyoto (Japan)), e-mail: akikido@kuhp.kyoto-u.ac.jp (and others)

    2010-11-15

    Background: Diffusion tensor imaging (DTI) at 3 T provides information on the microstructure and pathophysiology of tissues that is not available from conventional imaging with an advantage of high signal to noise ratio (SNR). Purpose: To evaluate the feasibility of DTI of the normal kidney at 3.0 T compared to results obtained at 1.5 T. Material and Methods: DTI of the normal kidney of 15 healthy volunteers obtained with 3.0 and 1.5 T scanners using respiration-triggered acquisition was examined. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of both the renal cortex and the medulla and SNRs were measured (b-values 0 and 400 s/mm2, diffusion direction of 6). The image quality of FA and ADC maps was also compared subjectively. Results: The FA values of the renal cortex were 0.15 +- 0.03 at 3.0 T and 0.14+- 0.03 at 1.5 T on average. This difference was not significant. The FA values of the renal medulla were 0.49 +-0.04 at 3.0 T and 0.42 +- 0.05 at 1.5 T. ADC values of the renal cortex were 2.46 x 10-3+- 0.09 mm2/s at 3.0 T and 2.20 x10-3+-0.11 mm2/s at 1.5 T. The ADC values of the renal medulla were 2.08 x 10-3 +- 0.08 mm2/s at 3.0 T and 1.90 x 10-3+- 0.11 mm2/s at 1.5 T. These FA and ADC values were consistent with previous publications. The difference was significant for the FA value of the medulla (P< 0.01) and ADC values in both cortex and medulla (P < 0.01). The subjective image quality of the FA map with the 3.0 T scanner was significantly superior to that with the 1.5 T scanner (P< 0.01), but not significant for the ADC map (P = 0.18). There was a significant difference in SNR between 3.0 T (48.8 +- 6.6) and 1.5 T images (32.8 +- 5.0). Conclusion: The feasibility of renal DTI with a 3.0 T magnet resulting in improved SNR was demonstrated

  14. Characterizing the pseudogap in the high- Tc superconductors using very high magnetic fields: implications on the phase diagram

    Science.gov (United States)

    Zheng, Guo-qing; Ozaki, H.; Kitaoka, Y.; Clark, W. G.; Kodama, Y.; Kondo, T.; Shimakawa, Y.; Kubo, Y.; Kuhns, P.; Reyes, A. P.; Moulton, W. G.

    2001-11-01

    We find contrastive response of the pseudogap (PG) to high magnetic fields up to 28.5 T based on 63Cu NMR measurements. In the slightly overdoped TlSr 2CaCu 2O 6.8, the PG is strongly field dependent and shown to be due to the superconducting fluctuations. By contrast, the PG in the underdoped YBa 2Cu 4O 8 does not depend on magnetic fields up to 28.5 T. These results imply that there exists a field-insensitive PG up to a certain doping level beyond which it is taken over by the superconducting fluctuations-induced one.

  15. Towards {sup 31}Mg-β-NMR resonance linewidths adequate for applications in magnesium chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Stachura, M., E-mail: mstachura@triumf.ca [TRIUMF (Canada); McFadden, R. M. L. [University of British Columbia, Chemistry Department (Canada); Chatzichristos, A.; Dehn, M. H. [University of British Columbia, Department of Physics and Astronomy (Canada); Gottberg, A. [TRIUMF (Canada); Hemmingsen, L. [Københavns Universitet Universitetsparken 5, Kemisk Institut (Denmark); Jancso, A. [University of Szeged, Department of Inorganic and Analytical Chemistry (Hungary); Karner, V. L. [University of British Columbia, Chemistry Department (Canada); Kiefl, R. F. [University of British Columbia, Department of Physics and Astronomy (Canada); Larsen, F. H. [Københavns Universitet Rolighedsvej 26, Institut for Fødevarevidenskab (Denmark); Lassen, J.; Levy, C. D. P.; Li, R. [TRIUMF (Canada); MacFarlane, W. A. [University of British Columbia, Chemistry Department (Canada); Morris, G. D. [TRIUMF (Canada); Pallada, S. [CERN (Switzerland); Pearson, M. R. [TRIUMF (Canada); Szunyogh, D.; Thulstrup, P. W. [Københavns Universitet Universitetsparken 5, Kemisk Institut (Denmark); Voss, A. [University of Jyväskylä, Department of Physics (Finland)

    2017-11-15

    The span of most chemical shifts recorded in conventional {sup 25}Mg-NMR spectroscopy is ~ 100 ppm. Accordingly, linewidths of ~ 10 ppm or better are desirable to achieve adequate resolution for applications in chemistry. Here we present first high-field {sup 31}Mg- β-NMR measurements of {sup 31}Mg{sup +} ions implanted into a MgO single crystal carried out at the ISAC facility at TRIUMF. The resonances recorded at 2.5 T and 3.5 T show strong linewidth dependency on the applied RF power, ranging from ~ 419 ppm for the highest RF power down to ~ 48 ppm for the lowest one.

  16. Forced volume magnetostriction in Mn3.3Sn0.7C compound at room temperature

    International Nuclear Information System (INIS)

    Wen Yongchun; Wang Cong; Sun Ying; Nie Man; Chu Lihua

    2010-01-01

    The negative volume magnetostriction in the external magnetic field for antiperovskite Mn 3.3 Sn 0.7 C compound is discovered. Its magnetic transition temperature from paramagnetism to ferrimagnetism is 348 K. The linear and volume magnetostrictions were investigated by measuring the change in length along the three-dimensional directions of the square samples at room temperature. Volume contraction was observed along all of the three directions throughout the whole magnetization. The value of volume magnetostriction is -44x10 -6 at 1.5 T. The magnetization saturates basically at 1.5 T, however the volume magnetostriction should be higher with further increase in magnetic field.

  17. Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics

    International Nuclear Information System (INIS)

    Lu, W.; Lin, S. H.; Xie, D. Z.; Zhang, X. Z.; Sha, S.; Zhang, W. H.; Cao, Y.; Guo, J. W.; Fang, X.; Guo, X. H.; Li, X. X.; Ma, H. Y.; Wu, Q.; Zhao, H. Y.; Ma, B. H.; Wang, H.; Zhu, Y. H.; Feng, Y. C.; Li, J. Y.; Li, J. Q.

    2012-01-01

    A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

  18. Studies of relative gain and timing response of fine-mesh photomultiplier tubes in high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Sulkosky, V.; Allison, L.; Barber, C.; Cao, T.; Ilieva, Y.; Jin, K.; Kalicy, G.; Park, K.; Ton, N.; Zheng, X.

    2016-08-01

    We investigated the use of Hamamatsu fine-mesh photomultiplier tube assemblies H6152-70 and H6614-70 with regards to their gain and timing resolution in magnetic fields up to 1.9 T. Our results show that the H6614-70 assembly can operate reliably in magnetic fields exceeding 1.5 T, while preserving a reasonable timing resolution even with a gain reduction of a factor of ~100. The reduction of the relative gain of the H6152-70 is similar to the H6614-70's near 1.5 T, but its timing resolution worsens considerably at this high field.

  19. Marinobacter lacisalsi sp. nov., a moderately halophilic bacterium isolated from the saline-wetland wildfowl reserve Fuente de Piedra in southern Spain.

    Science.gov (United States)

    Aguilera, Margarita; Jiménez-Pranteda, Maria L; Kharroub, Karima; González-Paredes, Ana; Durban, Juan J; Russell, Nick J; Ramos-Cormenzana, Alberto; Monteoliva-Sánchez, Mercedes

    2009-07-01

    A Gram-negative, non-spore-forming, motile, moderately halophilic, aerobic, rod-shaped bacterium, designated strain FP2.5(T), was isolated from the inland hypersaline lake Fuente de Piedra, a saline-wetland wildfowl reserve located in the province of Málaga in southern Spain. Strain FP2.5(T) was subjected to a polyphasic taxonomic study. It produced colonies with a light-yellow pigment. Strain FP2.5(T) grew at salinities of 3-15 % (w/v) and at temperatures of 20-40 degrees C. The pH range for growth was 5-9. Strain FP2.5(T) was able to utilize various organic acids as sole carbon and energy source. Its major fatty acids were C(16 : 0), C(18 : 1)omega9c and C(16 : 1)omega9c. The DNA G+C content was 58.6 mol%. Phylogenetic analysis based on 16S rRNA gene sequences showed that strain FP2.5(T) appeared to be a member of the genus Marinobacter and clustered closely with the type strains of Marinobacter segnicrescens, Marinobacter bryozoorum and Marinobacter gudaonensis (levels of 16S rRNA gene sequence similarity of 98.1, 97.4 and 97.2 %, respectively). However, DNA-DNA relatedness between the new isolate and the type strains of its closest related Marinobacter species was low; levels of DNA-DNA relatedness between strain FP2.5(T) and M. segnicrescens LMG 23928(T), M. bryozoorum DSM 15401(T) and M. gudaonensis DSM 18066(T) were 36.3, 32.1 and 24.9 %, respectively. On the basis of phenotypic characteristics, phylogenetic analysis and DNA-DNA relatedness data, strain FP2.5(T) is considered to represent a novel species of the genus Marinobacter, for which the name Marinobacter lacisalsi sp. nov. is proposed. The type strain is FP2.5(T) (=CECT 7297(T)=LMG 24237(T)).

  20. Diffusion tensor MRI of the kidney at 3.0 and 1.5 Tesla

    International Nuclear Information System (INIS)

    Kido, Aki; Kataoka, Masako; Yamamoto, Akira

    2010-01-01

    Background: Diffusion tensor imaging (DTI) at 3 T provides information on the microstructure and pathophysiology of tissues that is not available from conventional imaging with an advantage of high signal to noise ratio (SNR). Purpose: To evaluate the feasibility of DTI of the normal kidney at 3.0 T compared to results obtained at 1.5 T. Material and Methods: DTI of the normal kidney of 15 healthy volunteers obtained with 3.0 and 1.5 T scanners using respiration-triggered acquisition was examined. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of both the renal cortex and the medulla and SNRs were measured (b-values 0 and 400 s/mm 2 , diffusion direction of 6). The image quality of FA and ADC maps was also compared subjectively. Results: The FA values of the renal cortex were 0.15 ± 0.03 at 3.0 T and 0.14± 0.03 at 1.5 T on average. This difference was not significant. The FA values of the renal medulla were 0.49 ±0.04 at 3.0 T and 0.42 ± 0.05 at 1.5 T. ADC values of the renal cortex were 2.46 x 10 -3 ± 0.09 mm 2 /s at 3.0 T and 2.20 x10 -3 ±0.11 mm 2 /s at 1.5 T. The ADC values of the renal medulla were 2.08 x 10 -3 ± 0.08 mm 2 /s at 3.0 T and 1.90 x 10 -3 ± 0.11 mm 2 /s at 1.5 T. These FA and ADC values were consistent with previous publications. The difference was significant for the FA value of the medulla (P< 0.01) and ADC values in both cortex and medulla (P < 0.01). The subjective image quality of the FA map with the 3.0 T scanner was significantly superior to that with the 1.5 T scanner (P< 0.01), but not significant for the ADC map (P = 0.18). There was a significant difference in SNR between 3.0 T (48.8 ± 6.6) and 1.5 T images (32.8 ± 5.0). Conclusion: The feasibility of renal DTI with a 3.0 T magnet resulting in improved SNR was demonstrated

  1. 3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

    Science.gov (United States)

    Girometti, Rossano

    2015-01-01

    An ever-increasing number of 3.0 Tesla (T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength. PMID:26244063

  2. Support from the Army Research Office to be Used Towards Student Travel Fellowships for the National Radio Science Meetings in January 2010, 2011, and 2012

    Science.gov (United States)

    2012-08-06

    K2-2 COMPUTATIONAL STUDY OF EXTERNAL FIXATION DEVICES SURFACE HEATING IN 1.5T AND 3T MRI SYSTEMS Yan Liu*1, Jianxiang Shen1, Ji Chen1, Wolfgang...communications have been ex- panding rapidly with the proliferation of consumer wireless devices such as smart phones, tablet PCs, handheld gaming devices, and...Computational Study of External Fixation Devices Surface Heating in 1.5T and 3T MRI Systems Yan Liu* (1) , Jianxiang Shen (1) , Ji Chen (1) , and

  3. GIS aided spatial disaggregation of emission inventories

    International Nuclear Information System (INIS)

    Orthofer, R.; Loibl, W.

    1995-10-01

    We have applied our method to produce detailed NMVOC and NO x emission density maps for Austria. While theoretical average emission densities for the whole country would be only 5 t NMVOC and 2.5 t NO x per km 2 , the actual emission densities range from zero in the many uninhabited areas up to more than 3,000 t/km 2 along major highways. In Austria, small scale disaggregation is necessary particularly for the differentiated topography and population patterns in alpine valleys. (author)

  4. 3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

    Science.gov (United States)

    Girometti, Rossano

    2015-07-28

    An ever-increasing number of 3.0 Tesla (T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength.

  5. Flight decks -- a new breed takes pipeline and oilfield helms built on advanced communications

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, G.

    2000-12-04

    Alliance Pipelines is a $5 billion asset, capable of delivering $9 billion-worth of natural gas a year at current prices. This paper provides a wealth of detail about the the communication system designed to control this 3,725 kms long pipeline extending between Fort St. John in northern British Columbia to Chicago, Illinois. The system is said to be an absolute masterpiece of the latest in communications and computer technology, run by the energy industry's counterparts to jumbo jet pilots. It was chosen over the much cheaper Internet which, despite all efforts to date, can be rendered impotent by hackers. Alliance represents the biggest Canadian step yet into the brave new world of 'e-pipe', a part of an accelerating evolution towards what has been described by Microsoft, its creators, as the 'digital nervous system'. Underlying the development of this and other similar systems is the assumption that the traditional linear manufacturing process, a 'flow line' from raw materials to supplier to engineering to production to distributor to end user, is fast being replaced by an interactive, dynamic consumer-driven business model that demands real-time access to all information needed for concurrent decision making at every level in the virtual organization. This system, called the Business Internet Enabled Energy Enterprise, can be achieved only through the use of information technology systems that support the integration of applications, information flow and communication to the fullest extent. A similar German System, called HISS, (Human Interface Supervision System) is a network that takes over seeing, hearing, and smelling industrial operations, learning lessons taught by the senses, remembering the correct responses to problems, and automatically directing the responses to be made. In addition to Alliance Pipelines, other Canadian applications of the digital nervous system or electronic intelligence reach from the study of oil

  6. [Risk-benefit of some mollusks and processed fishes in the renal patient's diet].

    Science.gov (United States)

    Castro-González, M I; Miranda-Becerra, D; Pérez-Gil, R F

    2010-03-01

    The renal diet must include limited amounts of high quality protein, phosphorus P and potassium K. n-3 polyunsaturated fatty acids (n-3PUFA EPA and DHA), present in fishes and mollusks, render beneficial properties against progression of renal damage. The aim of this study was to evaluate protein PR, phosphorus P, potassium K, calcium Ca and n-3PUFA in processed fishes and mollusks as an alimentary option for renal patients. Canned tuna (water AA and oil AC), sardine in tomate sauce ST and chipotle SC and smoked salmon SA, fresh jumbo flying squid CA, common octopus PU and oyster OS were evaluated. Significant difference was detected (p <.0.05) for K between different types of fish. SA contained 38g/100g PR, 307 mg/100g of P, 371 mg/ 100g K and 106 mg/100g n-3PUFA. Sardines contained (279-304 mg/100g of P and 283-322 mg/100g K and tunas 142-160 mg/100g P and 141-154 mg/100g K. Tunas and sardines had elevated concentration of n-3PUFA (4114 and 4790 mg/ 100g respectively), P:n-3PUFA and K:n-3PUFA ratio was low in tunas (0.03) and sardines (0.06). AA and AC contained (10.1 and 11.1 mgP/gPR), while ST and SC provided 26.4-19.1 mg/P/gPR. n-3PUFA/gPR were similar for tunas and sardines (302-424mg/gPR). Mollusks: CA presented the highest values of P and PR (2.4 mg/100g and 18.4g/100g). n-3PUFA ranged from 4.3 to 79 mg/100g in PU and OS respectively. Among processed fishes, only canned tunas are recommended for the diet of renal patients, in an individualized basis. The risk-benefit ratio of sardines in the renal diet should be evaluated, due to their high content of P and n-3PUFA. Salmon and mollusks are not recommended for the renal diet.