WorldWideScience

Sample records for joint prosthesis systems

  1. Prosthesis infections after orthopedic joint replacement

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore...

  2. Life Estimation of Hip Joint Prosthesis

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  3. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    Clifford AG

    2013-05-01

    Full Text Available Anton G Clifford,1 Stefan M Gabriel,1 Mary O’Connell,1 David Lowe,1 Larry E Miller,2,3 Jon E Block31Moximed, Inc, Hayward, CA, USA; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USAAbstract: Symptomatic medial compartment knee osteoarthritis (OA is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA.Keywords: KineSpring, knee, medial, osteoarthritis, prosthesis

  4. Failed total carpometacarpal joint prosthesis of the thumb

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. T...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis.......Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis....... The male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...

  5. Strain-stress analysis of surface prosthesis of hip joint

    Návrat, Tomáš; Fuis, Vladimír; Florian, Z.; Hlavoň, Pavel

    2007-01-01

    Roč. 40, č. 2 (2007), S559-S559 ISSN 0021-9290. [ISB 2007. Taipei, 01.07.2007-05.07.2007] R&D Projects: GA ČR GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : surface prosthesis * hip joint * FEM Subject RIV: BO - Biophysics Impact factor: 2.897, year: 2007

  6. Prosthesis of the wrist-joint

    Feldmeier, C.

    1983-02-25

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated.

  7. Prosthesis of the wrist-joint

    Feldmeier, C.

    1983-01-01

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated. (orig.) [de

  8. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint ulnar (hemi-wrist) polymer prosthesis. 888.3810 Section 888.3810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-wrist) polymer prosthesis. (a) Identification. A wrist joint ulnar (hemi-wrist) polymer prosthesis...

  9. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  10. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  11. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  12. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  13. Reconstruction of chronic acromioclavicular joint disruption with artificial ligament prosthesis

    Chouhan Devendra Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: Management of Rockwood type 3 acromioclavicular disruptions is a matter of debate. Should we adopt conservative or operative measures at first presentation? It is not clear but most of the evidences are in favour of conservative management. We present our expe-rience in managing these patients surgically. Methods: We present a prospective series of eight cases of chronic Rockwood type 3 acromioclavicular joint disruptions treated surgically. Anatomical reconstruction of the coracoclavicular ligament was done by artificial braided polyester ligament prosthesis. Results: All the patients were able to perform daily activities from an average of the 14th postoperative day. All patients felt an improvement in pain, with decrease in ave-rage visual analogue scale from preoperative 6.5 points (range 3-9 points to 2.0 points (range 0-5 points, Constant score from 59% to 91% and American Shoulder and Elbow Surgeons shoulder score from 65 to 93 points postoperatively. These results improved or at least remained stationary on midterm follow-up, and no deterioration was recorded at an average follow-up of 46 months. Conclusion: This midterm outcome analysis of the artificial ligament prosthesis is the first such follow-up study with prosthesis. Our results are encouraging and justify the further use and evaluation of this relatively new and easily reproducible technique. Key words: Acromioclavicular joint; Prostheses and implants; Reconstructive surgical procedures; Ligaments

  14. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  15. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  16. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  17. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  18. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  19. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  20. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  1. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  2. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  3. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  4. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  5. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  6. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint... replace a hip joint. The device prevents dislocation in more than one anatomic plane and has components...

  7. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal... hip joint. The device limits translation and rotation in one or more planes via the geometry of its...

  8. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint... of a knee joint. The device limits translation or rotation in one or more planes and has components...

  9. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint... ankle joint. The device limits translation and rotation: in one or more planes via the geometry of its...

  10. Smart image processing system for retinal prosthesis.

    Weiland, James D; Parikh, Neha; Pradeep, Vivek; Medioni, Gerard

    2012-01-01

    Retinal prostheses for the blind have demonstrated the ability to provide the sensation of light in otherwise blind individuals. However, visual task performance in these patients remains poor relative to someone with normal vision. Computer vision algorithms for navigation and object detection were evaluated for their ability to improve task performance. Blind subjects navigating a mobility course had fewer collisions when using a wearable camera system that guided them on a safe path. Subjects using a retinal prosthesis simulator could locate objects more quickly when an object detection algorithm assisted them. Computer vision algorithms can assist retinal prosthesis patients and low-vision patients in general.

  11. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  12. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  13. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3350 Hip joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  14. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal constrained cemented or uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained...

  15. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  16. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer non-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3120 Ankle joint metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  17. 99m technetium-MDP bone scintigraphy in evaluation of painful joint prosthesis

    Milosevic, D.; Jaukovic, M.; Jaukovic, Lj.; Ajdinovic, B.

    2004-01-01

    In addition of clinical evaluation and x-ray radiography, the diagnosis of a loose joint prosthesis is often made by nuclear medicine imaging techniques. Differentiation between loosening and infected prosthesis is important for better treatment of those patients. Aim: The aim of this study was to reevaluate the scintigraphic patterns in patients with painful hip of knee arthroplasty. Material and Method: From 1996. to 2003. forty patients aged 49-78 years were referred for evaluation of possible loosening/infection joint prosthesis: 36 pts with 39 total/ partial hip prosthesis, 1 pt with knee prosthesis and 3 pts with history of previously extracted hip prosthesis due to infection. Whole body acquisition had been performed with a single head gamma camera three hours after the injection of 740 MBq 99m Tc-MDP. Scans were classified as: positive for loosening if abnormal uptake was shown at the tip of the prosthesis; positive for infection if diffuse abnormal uptake was shown around the implant; negative and indeterminate scans. Scintigraphic findings were compared to clinical follow up, histology or cultures. Results: Positive findings were found in 17 bone scans strongly suggesting loosening in 10 cases, infection of prosthesis in 4 cases and both loosening/infection in 3 cases. Bone scintigraphy was normal in 11pts. Scans of three pts with previously extracted hip prosthesis and scheduled for reimplatation, showed inhomogeneously and mildly increased uptake in femur. Most of scans classified as indeterminate (n=12) showed slightly increased tracer uptake in region of acetabular roof, greater or lesser tho chanter, suggesting bone remodeling due to the presence of implant, rather than loosening. Conclusion: 99m Tc-MDP bone scintigraphy had a significant role in assessing the painful joint prosthesis. Complementary diagnostic procedures should be considered in indeterminate scintiscans. (authors)

  18. Control of dental prosthesis system with microcontroller.

    Kapidere, M; Müldür, S; Güler, I

    2000-04-01

    In this study, a microcontroller-based electronic circuit was designed and implemented for dental prosthesis curing system. Heater, compressor and valve were controlled by 8-bit PIC16C64 microcontroller which is programmed using MPASM package. The temperature and time were controlled automatically by preset values which were inputted from keyboard while the pressure was kept constant. Calibration was controlled and the working range was tested. The test results showed that the system provided a good performance.

  19. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms

    Zhijun Song

    2013-06-01

    Full Text Available Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the host immune responses. The authors reviewed the related literature in the context of their clinical experience, and discussed the possible etiology and mechanism leading to the infections, especially problems related to bacterial biofilm, and prophylaxis and treatment of infection, including both microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed.

  20. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer/metal semi-constrained... Devices § 888.3358 Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis. (a) Identification. A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device...

  1. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  2. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  3. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  4. An experimental-numerical method for comparative analysis of joint prosthesis

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-01-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs

  5. A custom-made temporomandibular joint prosthesis for fabrication by selective laser melting: Finite element analysis.

    Xu, Xiangliang; Luo, Danmei; Guo, Chuanbin; Rong, Qiguo

    2017-08-01

    A novel and custom-made selective laser melting (SLM) 3D-printed alloplastic temporomandibular joint (TMJ) prosthesis is proposed. The titanium-6aluminium-4vanadium (Ti-6Al-4V) condyle component and ultra-high molecular weight polyethylene (UHMWPE) fossa component comprised the total alloplastic TMJ replacement prosthesis. For the condyle component, an optimized tetrahedral open-porous scaffold with combined connection structures, i.e. an inlay rod and an onlay plate, between the prosthesis and remaining mandible was designed. The trajectory of movement of the intact condyle was assessed via kinematic analysis to facilitate the design of the fossa component. The behaviours of the intact mandible and mandible with the prosthesis were compared. The biomechanical behaviour was analysed by assessing the stress distribution on the prosthesis and strain distribution on the mandible. After muscle force was applied, the magnitude of the compressive strain on the condyle neck of the mandible with the prosthesis was lower than that on the condyle neck of the intact mandible, with the exception of the area about the screws; additionally, the magnitude of the strain at the scaffold-bone interface was relatively high. Copyright © 2017. Published by Elsevier Ltd.

  6. Temporomandibular Joint Prosthesis - 3D-CT Reconstruction before and after Treatment

    Feltlová, E.; Dostálová, T.; Kašparová, M.; Daněk, J.; Hliňáková, P.; Hubáček, M.; Nedoma, Jiří

    2010-01-01

    Roč. 6, č. 1 (2010), s. 15-19 ISSN 1801-5603 Institutional research plan: CEZ:AV0Z10300504 Keywords : dentistry * maxillofacial surgery * partial TMJ prosthesis * three-dimensional computed tomography * magnetic resonance imaging * temporomandibular joint Subject RIV: BA - General Mathematics http://www.ejbi.cz/articles/201012/50/1.html

  7. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Bicentric bipolar hip prosthesis: A radiological study of movement at the interprosthetic joint

    Anil Kumar Rai

    2011-01-01

    Full Text Available Background: The bipolar hip prostheses after some time functions as a unipolar device. There is a need to change the design of bipolar hip prostheses to make it function as a bipolar device over a prolonged period of time. A bicentric bipolar hip prosthesis was used as an implant for various conditions of the hip. We evaluated the movement of this newly developed prosthesis at the interprosthetic joint radiologically at periodic intervals. Materials and Methods: Fifty two cases were operarted with the Bicentric bipolar prosthesis for indications like fracture neck of femur and various other diseases of the hip and were followed up with serial radiographs at periodic intervals to evaluate, what fraction of the total abduction at the hip was occurring at the interprosthetic joint. Results: In cases of intracapsular fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 33.74% (mean value of all the patients, which fell to 25.66% at 1.5 years. In indications for bipolar hemireplacement other than fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 71.71% (mean value and at 1.5 years it was 67.52%. Conclusion: This study shows the relative preservation of inner bearing movement in the bipolar hip prosthesis with time probably due its refined design. Further refinements are needed to make the prosthesis work better in patients of intracapsular fracture neck femur.

  9. Wear-testing of a temporomandibular joint prosthesis : UHMWPE and PTFE against a metal ball, in water and in serum

    Van Loon, JP; Verkerke, GJ; de Bont, LGM; Liem, RSB

    For a temporomandibular joint prosthesis, an estimation of the wear rate was needed, prior to patient application. Therefore, we determined the in vitro wear rate of the ball-socket articulation of this prosthesis, consisting of a metal head and an ultra-high molecular weight polyethylene (UHMWPE)

  10. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint... implanted in the human jaw to replace the mandibular condyle and augment the glenoid fossa to functionally...

  11. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  12. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  13. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular...

  14. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  15. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial (uni-compartmental) metal... Devices § 888.3535 Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint femorotibial (uni-compartmental) metal/polymer porous-coated...

  16. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/polymer semi-constrained...

  17. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  18. [Inferior hemiarthroplasty of the temporo-mandibular joint with articulated condylar prosthesis type Stryker].

    Bucur, A; Dincă, O; Totan, C; Ghită, V

    2007-01-01

    The optimal reconstruction of the mandible and of the temporo-mandibular joint after mandibular hemi-resection with disarticulation is still controversial in literature. This paperwork presents our experience on four cases in the reconstruction of the mandible together with the inferior arthroplasty of the temporo-mandibular joint, after the resection of extended benign tumors of the mandible, based on fibular free vascularized grafts having attached a Stryker titanium condylar prosthesis reconstructing the inferior segment of the temporo-mandibular joint. Our results for the this technique were excellent, with a functional rehabilitation very close to normal. After reviewing the various techniques and their arguments in literature, with accent on the TMJ reconstruction, we consider this method to be optimal for the reconstruction of mandibular defects in patients with neoplastic conditions.

  19. Calculation of wear (f.i. wear modulus) in the plastic cup of a hip joint prosthesis

    Ligterink, D.J.

    1975-01-01

    The wear equation is applied to the wear process in a hip joint prosthesis and a wear modulus is defined. The sliding distance, wear modulus, wear volume, wear area, contact angle and the maximum normal stress were calculated and the theoretical calculations applied to test results. During the wear

  20. Visual prosthesis wireless energy transfer system optimal modeling.

    Li, Xueping; Yang, Yuan; Gao, Yong

    2014-01-16

    Wireless energy transfer system is an effective way to solve the visual prosthesis energy supply problems, theoretical modeling of the system is the prerequisite to do optimal energy transfer system design. On the basis of the ideal model of the wireless energy transfer system, according to visual prosthesis application condition, the system modeling is optimized. During the optimal modeling, taking planar spiral coils as the coupling devices between energy transmitter and receiver, the effect of the parasitic capacitance of the transfer coil is considered, and especially the concept of biological capacitance is proposed to consider the influence of biological tissue on the energy transfer efficiency, resulting in the optimal modeling's more accuracy for the actual application. The simulation data of the optimal model in this paper is compared with that of the previous ideal model, the results show that under high frequency condition, the parasitic capacitance of inductance and biological capacitance considered in the optimal model could have great impact on the wireless energy transfer system. The further comparison with the experimental data verifies the validity and accuracy of the optimal model proposed in this paper. The optimal model proposed in this paper has a higher theoretical guiding significance for the wireless energy transfer system's further research, and provide a more precise model reference for solving the power supply problem in visual prosthesis clinical application.

  1. Viability of pHEMA Hydrogels as Coating in Human Synovial Joint Prosthesis

    V.P. Bavaresco

    2002-10-01

    Full Text Available In artificial joints, the bone part is usually substituted by a metallic component with high corrosion and strength resistance while the articular cartilage is replaced by a polymer. Use of thin layer of a compliant material acting as a bearing surface in human replacement joints has recently generated considerable interest. This work analyses the coating of a solid porous substrate of Ultra High Molecular Weight Polyethylene (UHMWPE with a poly (2-hydroxyethyl methacrylate (pHEMA and two sIPN-type blends: pHEMA-cellulose acetate butyrate (CAB and pHEMA-poly (ethyl methacrylate (PEM using 5.0% (w/w of the crosslinking agent and 11.0% (w/w of the linear reinforcing polymer. The wear resistance of the coating materials was evaluated in a TRI PIN ON DISK type equipment and the damage extension was characterized by Scanning Electron Microscopy (SEM. Preliminary qualitative tests were performed with the goal to identifying the hydrogels show the minimal required properties concerning wear strength. The pHEMA coating was completely destroyed during the first wear cycles, characterizing its low shear strength. By the other hand, after the complete experiment, both pHEMA-CAB and pHEMA-PEM blends showed a slightly improvement of abrasive and adhesive wear. This result indicates that the studied blends are promising materials to be used as compliant surfaces in joint prosthesis.

  2. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Long-Term Symptoms Onset and Heterotopic Bone Formation around a Total Temporomandibular Joint Prosthesis: a Case Report

    Luca Guarda-Nardini

    2014-04-01

    Full Text Available Background: The literature on total alloplastic temporomandibular joint (TMJ reconstructions is encouraging, and studies on total alloplastic TMJ replacements outcomes showed acceptable improvements in terms of both pain levels and jaw function. Nevertheless, some adverse events, such as heterotopic bone formation around the implanted prosthesis, may occur. In consideration of that, the present manuscript describes a case of heterotopic bone formation around a total temporomandibular joint prosthesis, which occurred several years after the implant. Methods: The present manuscript describes a case of heterotopic bone formation around a total TMJ prosthesis, which occurred several years after the implant in patients, who previously underwent multiple failed TMJ surgeries. Results: Ten years after the surgical TMJ replacement to solve an ankylotic bone block, the patient came to our attention again referring a progressive limitation in mouth opening. A computerized tomography showed evidence of marked heterotopic bone formation in the medial aspects of the joint, where a new-born ankylotic block occupied most part of the gap created by resecting the coronoid process at the time of the TMJ prosthesis insertion. Conclusions: Despite this adverse event has been sometimes described in the literature, this is the first case in which its occurrence happened several years after the temporomandibular joint replacement. It can be suggested that an accurate assessment of pre-operative risk factors for re-ankylosis (e.g., patients with multiple failed temporomandibular joint surgeries and within-intervention prevention (e.g., strategies to keep the bone interfaces around the implant separated should be better standardized and define in future studies.

  4. A proposed intracortical visual prosthesis image processing system.

    Srivastava, N R; Troyk, P

    2005-01-01

    It has been a goal of neuroprosthesis researchers to develop a system, which could provide artifical vision to a large population of individuals with blindness. It has been demonstrated by earlier researches that stimulating the visual cortex area electrically can evoke spatial visual percepts, i.e. phosphenes. The goal of visual cortex prosthesis is to stimulate the visual cortex area and generate a visual perception in real time to restore vision. Even though the normal working of the visual system is not been completely understood, the existing knowledge has inspired research groups to develop strategies to develop visual cortex prosthesis which can help blind patients in their daily activities. A major limitation in this work is the development of an image proceessing system for converting an electronic image, as captured by a camera, into a real-time data stream for stimulation of the implanted electrodes. This paper proposes a system, which will capture the image using a camera and use a dedicated hardware real time image processor to deliver electrical pulses to intracortical electrodes. This system has to be flexible enough to adapt to individual patients and to various strategies of image reconstruction. Here we consider a preliminary architecture for this system.

  5. Nonlinear dynamical system approaches towards neural prosthesis

    Torikai, Hiroyuki; Hashimoto, Sho

    2011-01-01

    An asynchronous discrete-state spiking neurons is a wired system of shift registers that can mimic nonlinear dynamics of an ODE-based neuron model. The control parameter of the neuron is the wiring pattern among the registers and thus they are suitable for on-chip learning. In this paper an asynchronous discrete-state spiking neuron is introduced and its typical nonlinear phenomena are demonstrated. Also, a learning algorithm for a set of neurons is presented and it is demonstrated that the algorithm enables the set of neurons to reconstruct nonlinear dynamics of another set of neurons with unknown parameter values. The learning function is validated by FPGA experiments.

  6. A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    Peerdeman, B.; van Baal, D.W.; Boere, Daphne; Kallenberg, L.A.C.; Stramigioli, Stefano; Misra, Sarthak

    2010-01-01

    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the

  7. An experimental-numerical method for comparative analysis of joint prosthesis; Un metodo numerico-experimental para el analisis comparativo de protesis articulares

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-07-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs.

  8. Relationship between removable prosthesis and some systemics disorders

    Pierre Le Bars

    2015-01-01

    Full Text Available This article reviews the dental literature concerning the potential impact of the removable prosthesis (RP on the health status of patients with certain systemic diseases. Literature was surveyed using Medline/PubMed database resources, as well as a manual search, up to 2015 to identify appropriate articles that addressed the aim of this review. The research used keywords about associations between RP and six pathologies: Human immunodeficiency virus infection, diabetes mellitus, pulmonary diseases, gastric-Helicobacter pylori, cancer, and cardiovascular diseases. Analysis of literature showed that in patients with dentures having one or more of the six general conditions listed, Candida albicans organism is more frequently found in the oral flora compared to healthy denture wearer. Although causality has not been established and pending further research on this topic, the hygienic practices necessary to minimize the risk of numerous pathologies should be strengthened in the case of these patients, all the more in the presence of physical or psychological disability. The relationship between the general diseases and increasing of oral candidiasis denture patients is not explained. Therefore, attention to oral hygiene and professional care for removing C. albicans may be beneficial in these medically compromised patients.

  9. Relationship between removable prosthesis and some systemics disorders.

    Le Bars, Pierre; Kouadio, Alain Ayepa; N'goran, Justin Koffi; Badran, Zahi; Soueidan, Assem

    2015-01-01

    This article reviews the dental literature concerning the potential impact of the removable prosthesis (RP) on the health status of patients with certain systemic diseases. Literature was surveyed using Medline/PubMed database resources, as well as a manual search, up to 2015 to identify appropriate articles that addressed the aim of this review. The research used keywords about associations between RP and six pathologies: Human immunodeficiency virus infection, diabetes mellitus, pulmonary diseases, gastric-Helicobacter pylori, cancer, and cardiovascular diseases. Analysis of literature showed that in patients with dentures having one or more of the six general conditions listed, Candida albicans organism is more frequently found in the oral flora compared to healthy denture wearer. Although causality has not been established and pending further research on this topic, the hygienic practices necessary to minimize the risk of numerous pathologies should be strengthened in the case of these patients, all the more in the presence of physical or psychological disability. The relationship between the general diseases and increasing of oral candidiasis denture patients is not explained. Therefore, attention to oral hygiene and professional care for removing C. albicans may be beneficial in these medically compromised patients.

  10. A unique method of retaining orbital prosthesis with attachment systems - a clinical report.

    Guttal, Satyabodh S; Akash, N R; Prithviraj, D R; Lekha, K

    2014-06-01

    Diminution of the orbital contents post-surgical removal of a malignant tumor can have a severe psychological impact on the patient in terms of function and esthetics. Therefore, esthetic remedy should be planned subsequently, since tumor obliteration precedes cosmetic concern. A convenient option for successful rehabilitation in such patients is a simple, user-friendly, removable orbital prosthesis. Retention of the prosthesis is one of the key factors for the successful rehabilitation. Spectacle frame, conformers, adhesives, osseointegrated implants, magnets or buttons have been used to impart retention to the prosthesis. The use of semi precision attachments in maxillofacial prostheses is limited to the osseointegrated prostheses. This case report describes a conventional spectacle frame technique, to retain the silicone orbital prosthesis using two different types of stud attachments viz., dalla bona and O-ring attachment systems. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. The Argus(®) II Retinal Prosthesis System.

    Luo, Yvonne Hsu-Lin; da Cruz, Lyndon

    2016-01-01

    The Argus(®) II Retinal Prosthesis System (Second Sight Medical Products) is the first prosthetic vision device to obtain regulatory approval in both Europe and the USA. As such it has entered the commercial market as a treatment for patients with profound vision loss from end-stage outer retinal disease, predominantly retinitis pigmentosa. To date, over 100 devices have been implanted worldwide, representing the largest group of patients currently treated with visual prostheses. The system works by direct stimulation of the relatively preserved inner retina via epiretinal microelectrodes, thereby replacing the function of the degenerated photoreceptors. Visual information from a glasses-mounted video camera is converted to a pixelated image by an external processor, before being transmitted to the microelectrode array at the macula. Elicited retinal responses are then relayed via the normal optic nerve to the cortex for interpretation. We reviewed the animal and human studies that led to the development of the Argus(®) II device. A sufficiently robust safety profile was demonstrated in the phase I/II clinical trial of 30 patients. Improvement of function in terms of orientation and mobility, target localisation, shape and object recognition, and reading of letters and short unrehearsed words have also been shown. There remains a wide variability in the functional outcomes amongst the patients and the factors contributing to these performance differences are still unclear. Future developments in terms of both software and hardware aimed at improving visual function have been proposed. Further experience in clinical outcomes is being acquired due to increasing implantation. Copyright © 2015. Published by Elsevier Ltd.

  12. Results of endoprosthetic hip joint replacement with the aluminum ceramic-metal composite prosthesis "Lindenhof".

    Stock, D; Diezemann, E D; Gottstein, J

    1980-01-01

    The first clinical results of the Lindenhof ceramic-metal composite prosthesis implanted in our hospital in Freiburg are presented. We observed that same favorable early results as the conventional prostheses in a correct position. The implants are incorporated into the bone within 8-12 weeks. The radiographic films show the adaptation of the supporting bone around the ceramic socket. We explain the failures due to our initial lack of technical experience and/or anatomical deformation of the pelvic bone. complications caused by the post-operative treatment during the 12 weeks following surgery did not occur. The combination of a cemented metal femoral component with a ceramic head seems to be a reasonable compromise to use the favorable physical and biochemical properties of the bioceramic material as long as there is no satisfactory solution for a stable cementless fixation of the femoral stem in to the bone. The advantages of the Lindenhof prosthesis predominate the disadvantages: expensive instruments and a post-operative treatment of several months.

  13. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  14. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...

  15. The impact of joint line restoration on functional results after hinged knee prosthesis

    Serdar Yilmaz

    2016-01-01

    Conclusion: RHKA is an effective salvage procedure for serious instability and large bone defects. Restoration of the joint line improves the patellar score although it had no effect on the clinical outcome.

  16. Development and performance of a new prosthesis system using ultrasonic sensor for wrist movements: a preliminary study

    2014-01-01

    Background The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user. Methods The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements. Results The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45° - 55° of rotation or about 14 cm – 16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation. Conclusion The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics. PMID:24755242

  17. Long-term outcome of acute prosthetic joint infections due to gram-negative bacilli treated with retention of prosthesis.

    Jaén, N; Martínez-Pastor, J C; Muñoz-Mahamud, E; García-Ramiro, S; Bosch, J; Mensa, J; Soriano, A

    2012-09-01

    To update the clinical information of the 47 patients with a prosthetic joint infection due to Gram-negative bacilli included in a previous study and to reassess the predictors of failure after a longer follow-up. Using the electronic files of our hospital, all the information regarding readmissions to the hospital, new surgical procedures and the reason for the new surgery (infection, aseptic loosening), and the last visit in the hospital were registered. The medical chart of the 35 patients that were considered in remission in the previous publication was reviewed. In 30 patients no clinical evidence of failure was detected and no additional surgery on the previously infected prosthesis was necessary and they were considered in long-term remission. In 5 cases a late complication was identified. One case had a reinfection due to coagulase-negative staphylococci after 22 months from the open debridement and required a 2-stage revision surgery. The other 4 cases developed an aseptic loosening and it was necessary to perform a 1-stage exchange. Receiving a fluoroquinolone when all the Gram-negatives involved in the infection were susceptible to fluoroquinolones was the only factor associated with remission in the univariate analysis (p=0.002). After a long-term follow-up, our results support the importance of using fluoroquinolones in acute PJI due to Gram-negative bacilli.

  18. Friction in total hip joint prosthesis measured in vivo during walking.

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  19. Friction in total hip joint prosthesis measured in vivo during walking.

    Philipp Damm

    Full Text Available Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06 at contralateral toe off to 0.06 (0.04 to 0.08 at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23 at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W. Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  20. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  1. Joint Performance and Planning System

    US Agency for International Development — A joint State/USAID system hosted by State that integrates resource and performance information at the program level and enables more flexible and frequent entry of...

  2. A Medical Wireless Measurement System for Hip Prosthesis Loosening Detection Based on Vibration Analysis

    Sebastian Sauer

    2013-01-01

    Full Text Available Vibration analysis is a promising approach in order to detect early hip prosthesis loosening, with the potential to extend the range of diagnostic tools currently available in clinical routine. Ongoing research efforts and developments in the area of multi-functional implants, which integrate sensors, wireless power supply, communication and signal processing, provide means to obtain valuable in vivo information otherwise not available. In the current work a medical wireless measurement system is presented, which is integrated in the femoral head of a hip prosthesis. The passive miniaturized system includes a 3-axis acceleration sensor and signal pre-processing based on a lock-in amplifier circuit. Bidirectional data communication and power supply is reached through inductive coupling with an operating frequency of 125 kHz in accordance with the ISO 18000-2 protocol standard. The system allows the acquisition of the acceleration frequency response of the femur-prosthesis system between 500 to 2500 Hz. Applied laboratory measurements with system prototypes on artificial bones and integrated prostheses demonstrate the feasibility of the measurement system approach, clearly showing differences in the vibration behavior due to an implant loosening. In addition a possibility to evaluate the non-linear mechanic system behavior is presented.

  3. On the analysis of using 3-coil wireless power transfer system in retinal prosthesis.

    Bai, Shun; Skafidas, Stan

    2014-01-01

    Designing a wireless power transmission system(WPTS) using inductive coupling has been investigated extensively in the last decade. Depending on the different configurations of the coupling system, there have been various designing methods to optimise the power transmission efficiency based on the tuning circuitry, quality factor optimisation and geometrical configuration. Recently, a 3-coil WPTS was introduced in retinal prosthesis to overcome the low power transferring efficiency due to low coupling coefficient. Here we present a method to analyse this 3-coil WPTS using the S-parameters to directly obtain maximum achievable power transferring efficiency. Through electromagnetic simulation, we brought a question on the condition of improvement using 3-coil WPTS in powering retinal prosthesis.

  4. Development of prosthesis grasp control systems on a robotic testbed

    Peerdeman, B.; Fabrizi, Ugo; Palli, Gianluca; Melchiorri, Claudio; Stramigioli, Stefano; Misra, Sarthak

    2012-01-01

    Modern myoelectric hand prostheses continue to increase in functionality, while their control is constrained by the limits of myoelectric input. This paper covers the development and testing of grasp control systems for multifunctional myoelectric prosthetic hands. The functionality of modern hand

  5. P3-7: On Prototyping a Visual Prosthesis System with Artificial Retina and Optic Nerve Based on Arrayed Microfibers

    Jian Hong Chen

    2012-10-01

    Full Text Available The traditional visual prosthesis system combines both a camera and a microelectrode array implanted on the visual neural network including retina, optic nerve, and visual cortex. Here, we introduce a new visual prosthesis system in which an artificial retina and optic nerve are demonstrated. The prototype of optic nerve for image transmission is comprised of arrayed PMMA microfibers with both ends connected with two planes, one functioned as retina for light reception and another attached to visual cortex. The microfibers are drawn from the thin film prepared by PMMA/chlorobenzene solution. Each micro fiber serves as an optical waveguide for the delivery of a single image pixel. It is demonstrated that with proper imaging optics, arrayed micro fibers could be lit as discrete light spots in accordance with the input image. Each micro fiber is expected to function as a stimulation unit for optical neural modulation in a visual prosthesis system.

  6. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment

    Lee, Christine; Tu, Hong Anh; Weir, Mark; Holubowich, Corinne

    2016-01-01

    Background Retinitis pigmentosa is a group of genetic disorders that involves the breakdown and loss of photoreceptors in the retina, resulting in progressive retinal degeneration and eventual blindness. The Argus II Retinal Prosthesis System is the only currently available surgical implantable device approved by Health Canada. It has been shown to improve visual function in patients with severe visual loss from advanced retinitis pigmentosa. The objective of this analysis was to examine the clinical effectiveness, cost-effectiveness, budget impact, and safety of the Argus II system in improving visual function, as well as exploring patient experiences with the system. Methods We performed a systematic search of the literature for studies examining the effects of the Argus II retinal prosthesis system in patients with advanced retinitis pigmentosa, and appraised the evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria, focusing on visual function, functional outcomes, quality of life, and adverse events. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care over a 10-year time horizon. We also conducted a 5-year budget impact analysis. We used a qualitative design and an interview methodology to examine patients’ lived experience, and we used a modified grounded theory methodology to analyze information from interviews. Transcripts were coded, and themes were compared against one another. Results One multicentre international study and one single-centre study were included in the clinical review. In both studies, patients showed improved visual function with the Argus II system. However, the sight-threatening surgical complication rate was substantial. In the base-case analysis, the Argus II system was cost-effective compared with standard care only if willingness-to-pay was more than $207,616 per quality-adjusted life

  7. MULTIPLE DAMAGE OF THE TIBIAL POLYETHYLENE INSERT IN KNEE JOINT PROSTHESIS (CAN EXCELLENT POSTOPERATIVE OUTCOME BE THE CAUSE OF FRACTURE OF THE TIBIAL INSERT? CASE REPORT AND LITERATURE REVIEW

    E. Song

    2016-01-01

    Full Text Available Despite improvements in prosthesis technology and use of high-quality materials in recent years, the number of revisions related to implant failures (4.7% remains high. Several phenomena were reported in literature as reasons for dislocation and fracture of tibial insert in mobile bearing prosthesis: incorrect positioning of components, discrepancy of extension and flexion balancing or ligament weakness. However, in our cases neither of these causes were observed. The authors consider that bio-physiological and biomechanical aspects of total knee arthroplasty and knee joint prosthesis should be thoroughly studied and implemented into the clinical practice. In the described cases, multiple damage of the insert due to flexion instability and “twist-hyperflexion” in overweight patients is perceived as the reason for failures.

  8. Description of the condition of the implant-prosthesis system: a transverse study

    Salazar Salgado, Walter

    2008-01-01

    Current condition of the implant-prosthesis system of the patients attended in the Facultad de Odontologia de la Universidad de Costa Rica is described, in the included period from January 2001 to December 2006. Parameters of comparison will be established for future evaluations. An appointment was scheduled with each patient to review. A radiovisiograph was used for digital radiography with parallel technique and radiographic positioners, for anterior and posterior sector. In addition, a questionnaire was applied to all patients. The percentage of survival of the implants placed in the years 2001-2006, is 95.2 % and 92.4 % of the patients are satisfied with the aesthetic aspect of their restoration [es

  9. Prosthetic replacement of the medial meniscus in cadaveric knees - Does the prosthesis mimic the functional behavior of the native meniscus?

    Tienen, TG; Verdonschot, N; Heijkants, RGJC; Buma, R; Scholten, JGF; van Kampen, A; Veth, RPH

    2004-01-01

    Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. Hypothesis: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. Study Design: Controlled laboratory

  10. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  11. A new three-dimensional, print-on-demand temporomandibular prosthetic total joint replacement system: Preliminary outcomes.

    Dimitroulis, George; Austin, Stephen; Sin Lee, Peter Vee; Ackland, David

    2018-05-16

    The aim of this study is to present the preliminary clinical data on the OMX Temporomandibular Joint (TMJ) Prosthetic total joint replacement system. A prospective, cohort, clinical study was undertaken of consecutive adult patients with Category 5 end-stage joint disease who were implanted with the OMX TMJ prosthesis between May 2015 and April 2017. A total of 50 devices were implanted in 38 patients, with 12 patients receiving bilateral prosthetic joints. There were 31 females and 7 males in this cohort, who ranged in age from 20 to 66 years, with a mean of 43.8 years (±14.0 years). Ten of the 50 prosthetic joints (20%) were fully customized, while the remaining were patient matched using virtual planning software. Based on a mean follow-up period of 15.3 months (range 12-24 months) following the TMJ total joint replacement, preliminary results suggest the OMX TMJ prosthesis has made a positive impact on clinical outcomes, with a mean 74.4% reduction in joint pain levels and significant improvements (p < 0.05) in jaw function as measured by the visual analogue scales for mouth opening (30.8%), diet (77.1%), and function (59.2%). No device failures were reported during the study period. This study suggests that the print-on-demand OMX TMJ prosthesis, designed for rapid delivery of both patient-matched and fully customize devices, represents a safe, reliable and versatile implantable joint replacement system for the treatment of category 5 end-stage TMJ disease. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  13. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    2010-04-01

    ... linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be... ceramic (aluminium oxide, A1203) head of the femoral component. The acetabular component is made of ultra... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  14. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    Siddiq, M.Z.; Qayum, H.

    2006-01-01

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  15. Leaving a joint audit system

    Holm, Claus; Thinggaard, Frank

    2014-01-01

    determinants model and an audit fee change model and include interaction terms. Findings: The authors find short-term fee reductions in companies switching to single audits, but only where the former joint audit contained a dominant auditor. The authors argue that in this situation bargaining power is more...... with the auditors than in a equally shared joint audit, and that the auditors' incentives to offer an initial fee discount are bigger. Research limitations/implications: The number of observations is constrained by the small Danish capital market. Future research could take a more qualitative research approach......, to examine whether the use of a single audit firm rather than two has an effect on audit quality. The area calls for further theory development covering audit fee and audit quality in joint audit settings. Practical implications: Comapnies should consider their relationship with their auditors before...

  16. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment Update

    Lee, Christine; Tu, Hong Anh; Wells, David; Holubowich, Corinne

    2017-01-01

    Background Retinitis pigmentosa is a group of inherited disorders characterized by the degeneration of the photoreceptors in the retina, resulting in progressive vision loss. The Argus II system is designed to restore partial functional vision in patients with profound vision loss from advanced retinitis pigmentosa. At present, it is the only treatment option approved by Health Canada for this patient population. In June 2016, Health Quality Ontario published a health technology assessment of the Argus II retinal prosthesis system for patients with advanced retinitis pigmentosa. Based on that assessment, the Ontario Health Technology Advisory Committee recommended against publicly funding the Argus II system for this population. It also recommended that Health Quality Ontario re-evaluate the evidence in 1 year. The objective of this report was to examine new evidence published since the 2016 health technology assessment. Methods We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences related to the Argus II system. We performed a systematic literature search for studies published since the 2016 Argus II health technology assessment. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care, and we calculated incremental cost-effectiveness ratios over a 20-year time horizon. We also conducted a five-year budget impact analysis. Finally, we interviewed people with retinitis pigmentosa about their lived experience with vision loss, and with the Argus II system. Results Four publications from one multicentre international study were included in the clinical review. Patients showed significant improvements in visual function and functional outcomes with the Argus II system, and these outcomes were sustained up to a 5-year follow-up (moderate quality of evidence). The safety profile was generally acceptable. In

  17. Five-year safety and performance results from the Argus II Retinal Prosthesis System clinical trial

    da Cruz, Lyndon; Dorn, Jessy D.; Humayun, Mark S.; Dagnelie, Gislin; Handa, James; Barale, Pierre-Olivier; Sahel, José-Alain; Stanga, Paulo E.; Hafezi, Farhad; Safran, Avinoam B.; Salzmann, Joel; Santos, Arturo; Birch, David; Spencer, Rand; Cideciyan, Artur V.; de Juan, Eugene; Duncan, Jacque L.; Eliott, Dean; Fawzi, Amani; Olmos de Koo, Lisa C.; Ho, Allen C.; Brown, Gary; Haller, Julia; Regillo, Carl; Del Priore, Lucian V.; Arditi, Aries; Greenberg, Robert J.

    2016-01-01

    Purpose The Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) was developed to restore some vision to patients blind from retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception due to end-stage RP. Design The study is a prospective, multicenter, single-arm, clinical trial. Within-patient controls included the non-implanted fellow eye and patients' native residual vision compared to their vision when using the System. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Methods The worse-seeing eye of blind patients was implanted with the Argus II System. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Secondary measures included functional vision performance on objectively-scored real-world tasks. Results Twenty-four out of 30 patients remained implanted with functioning Argus II Systems at 5 years post-implant. Only one additional serious adverse event was experienced since the 3-year time point. Patients performed significantly better with the System ON than OFF on all visual function tests and functional vision tasks. Conclusions The five-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada. PMID:27453256

  18. Control of a Robotic Hand Using a Tongue Control System-A Prosthesis Application.

    Johansen, Daniel; Cipriani, Christian; Popovic, Dejan B; Struijk, Lotte N S A

    2016-07-01

    The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms. This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric. Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s). The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme. For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.

  19. Five-Year Safety and Performance Results from the Argus II Retinal Prosthesis System Clinical Trial.

    da Cruz, Lyndon; Dorn, Jessy D; Humayun, Mark S; Dagnelie, Gislin; Handa, James; Barale, Pierre-Olivier; Sahel, José-Alain; Stanga, Paulo E; Hafezi, Farhad; Safran, Avinoam B; Salzmann, Joel; Santos, Arturo; Birch, David; Spencer, Rand; Cideciyan, Artur V; de Juan, Eugene; Duncan, Jacque L; Eliott, Dean; Fawzi, Amani; Olmos de Koo, Lisa C; Ho, Allen C; Brown, Gary; Haller, Julia; Regillo, Carl; Del Priore, Lucian V; Arditi, Aries; Greenberg, Robert J

    2016-10-01

    The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP. Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II. Thirty participants in 10 centers in the United States and Europe. The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks. Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks. The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Decision Fusion System for Bolted Joint Monitoring

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  1. Colorado River Sewer System Joint Venture to Upgrade Wastewater System

    SAN FRANCISCO -Today, the Colorado River Sewer System Joint Venture, located in Parker, Ariz. entered into an agreement with the EPA to upgrade their wastewater treatment system to meet stringent water quality standards. The cost of the upgrade is ap

  2. The Joint Lessons Learned System and Interoperability

    1989-06-02

    Learned: 1988-1989 As mentioned in the introduction to this chaoter, the Organizacion of the JcinC Chiefs cf Staff .OJCS) ueren significant transformatioi...Organization and Functions Manual . Washington, D.C.: HQDA, Office of the Deputy Chief 0f Staff for Operations and Plans, June 1984. ’..S. Army. Concept...U.S. Department of Defense. Joint Universal Lessons Learned System (JULLS) User’s Manual . Orlando, Florida: University of Central Florida, Institute

  3. Joint Logistics Systems Center Reporting of Systems Development Costs

    1998-01-01

    ...." The Joint Logistics Systems Center (JLSC) was organized in FY 1992 to accomplish Corporate Information Management goals for the depot maintenance and supply management business areas of the DoD Working Capital Funds...

  4. Evaluation of Gait Performance of a Hemipelvectomy Amputation Walking with a Canadian Prosthesis

    M. T. Karimi

    2014-01-01

    Full Text Available Background. Hemipelvectomy amputation is a surgical procedure in which lower limb and a portion of pelvic are removed. There are a few studies in the literature regarding the performance of subjects with hip disarticulation during walking. However, there is no study on gait analysis of hemipelvectomy subject. Therefore, the aim of this paper was to evaluate the gait and stability of subject with hemipelvectomy amputation. Case Description and Methods. A subject with hemipelvectomy amputation at right side was involved in this study. He used a Canadian prosthesis with single axis ankle joint, 3R21 knee joint, and 7E7 hip joint for more than 10 years. The kinetic and kinematic parameters were collected by a motion analysis system and a Kistler force platform. Findings and Outcomes. There was a significant difference between knee, hip, and ankle range of motions and their moments in the sound and prosthesis sides. In the other side, the stability of the subject in the anteroposterior direction seems to be better than that in the mediolateral direction. Conclusions. There was a significant asymmetry between the kinetic and kinematic performance of the sound and prosthesis sides, which may be due to lack of muscular power and alignment of prosthesis components.

  5. High mid-term revision rate after treatment of large, full-thickness cartilage lesions and OA in the patellofemoral joint using a large inlay resurfacing prosthesis

    Laursen, Jens Ole

    2017-01-01

    PURPOSE: The HemiCAP-Wave® implant for the patellofemoral resurfacing treatment of large cartilage lesions and osteoarthritis (OA) was introduced in 2009. The outcome of a prospective cohort study of 18 patients with large trochlea lesions or isolated OA treated with the HemiCAP-Wave® implant...... pain but high mid-term revision rate after patellofemoral inlay resurfacing using the HemiCAP-Wave® implant. Patellofemoral resurfacing implantation treatment with a large inlay prosthesis can offer temporary treatment for large isolated patellofemoral cartilage lesions or OA in younger patients...

  6. Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking

    Alessandro Ruggiero

    2018-04-01

    Full Text Available The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.

  7. Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking.

    Ruggiero, Alessandro; Merola, Massimiliano; Affatato, Saverio

    2018-04-09

    The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.

  8. Elevated sacroilac joint uptake ratios in systemic lupus erythematosus

    De Smet, A.A.; Mahmood, T.; Robinson, R.G.; Lindsley, H.B.

    1984-01-01

    Sacroiliac joint radiographs and radionuclide sacroiliac joint uptake ratios were obtained on 14 patients with active systemic lupus erythematosus. Elevated joint ratios were found unilaterally in two patients and bilaterally in seven patients when their lupus was active. In patients whose disease became quiescent, the uptake ratios returned to normal. Two patients had persistently elevated ratios with continued clinical and laboratory evidence of active lupus. Mild sacroiliac joint sclerosis and erosions were detected on pelvic radiographs in these same two patients. Elevated quantitative sacroiliac joint uptake ratios may occur as a manifestation of active systemic lupus erythematosus

  9. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  10. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system.

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry(®) SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed.

  11. Alloplastic temporomandibular joint replacement systems: a systematic review of their history.

    De Meurechy, N; Mommaerts, M Y

    2018-06-01

    This systematic review provides an overview of the historical evolution of the prosthetic temporomandibular joint and addresses the challenges and complications faced by engineers and surgeons, in an effort to shed light on why only a few systems remain available. A better understanding of the history of temporomandibular joint prostheses might also provide insights into the origin of the negative public opinion of the prosthesis, which is based on outdated information. A computerized search using the PubMed Central, ScienceDirect, Wiley Online, Ovid, and Cochrane Library databases was performed following the PRISMA guidelines. Out of 7122 articles identified, 41 met the inclusion criteria for this systematic review. Although several historical reviews have been published previously, none has covered such an extensive time period or has described all designs. Furthermore, besides providing a historical overview, this review discusses the rationale behind the evolution in design and biomaterials, which have largely contributed to the outcomes of the prosthetic systems. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Communication Protocol for Advanced Prosthesis Components

    Karnå, David

    2007-01-01

    It would be of great value for the prosthesis industry to achieve an open standard for communication in upper limb prostheses. Cooperation between NTNU and the University of New Brunswick has resulted in a functional requirements specification for such a standard, SCIP(Standardised Communication Interface in Prostheses). The special challenges for communication in a prosthesis system are possible noisy environments, high demands for light weight, safety for the user and the fact that devices ...

  13. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss

    Tomaszewski, P. M.; van Diest, M.; Bulstra, S. K.; Verdonschot, N.; Verkerke, G. J.

    2012-01-01

    Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system. Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining

  14. Implant Failure After Motec Wrist Joint Prosthesis Due to Failure of Ball and Socket-Type Articulation-Two Patients With Adverse Reaction to Metal Debris and Polyether Ether Ketone.

    Karjalainen, Teemu; Pamilo, Konsta; Reito, Aleksi

    2018-04-21

    We describe 2 cases of articulation-related failures resulting in revision surgery after a Motec total wrist arthroplasty: one with an adverse reaction to metal debris and the other with an adverse reaction to polyether ether ketone. In the first patient, blood cobalt and chrome levels were elevated and magnetic resonance imaging showed clear signs of a pseudotumor. The other patient had an extensive release of polyether ether ketone particles into the surrounding synovia due to adverse wear conditions in the cup, leading to the formation of a fluid-filled cyst sac with a black lining and diffuse lymphocyte-dominated inflammation in the synovia. We recommend regular follow-up including x-rays, monitoring of cobalt and chrome ion levels, and a low threshold for cross-sectional imaging in patients who have undergone total wrist arthroplasty with a Motec joint prosthesis. Wear-related problems can also develop in implants in which polyether ether ketone is the bulk material. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. The Angelchik prosthesis

    Fargnoli, R.; Bozza, A.; Magnoli, A.; Villari, N.; Pernice, L.M.; Andreoli, F.; Lombardi, P.

    1989-01-01

    The Angelchik prosthesis is used in the surgical treatment of gastroesophageal reflux. Operated patients are preliminary examined with imaging techniques, but manometric and acidometric techniques are also used. Although the conventional esophagogram still maintains its diagnostic significance, Computed Tomography (CT) has become the first-choice imaging modality. CT allows the correct evaluation of both the state of the prosthesis and its relationship to the esophagus and gastric fundus. The possible postoperative complications following an incorrect placement of the prosthesis can be accurately diagnosed too. The authors report their experience in the study of 5 patients examined with both conventional radiology and CT

  16. Modified traditional Japanese timber joint system with retrofitting abilities

    Shiratori, T.; Komatsu, K.; Leijten, A.J.M.

    2008-01-01

    Embedment is a key feature of timber joints envisioned as the ultimate solution in avoiding the devastating full collapse of timber structures in seismic countries. The Japanese traditional timber post-and-beam structural system utilizes moment-resisting joints based on embedment. Despite the

  17. A prospective, single-centre study on patient outcomes following temporomandibular joint replacement using a custom-made Biomet TMJ prosthesis

    Aagaard, Esben; Thygesen, T.

    2014-01-01

    This study describes the clinical variables in 61 patients following total alloplastic temporomandibular joint reconstruction (TJR) in which the Biomet Microfixation Patient-Patient-Matched TMJ Implant was used. All patients were classified using the Wilkes classification. The visual analogue scale...... score for jaw pain intensity, the maximum inter-incisal opening (MK)), and the frequency of adverse events were recorded during follow-up; the mean follow-up was 14.2 8.6 months. Significant improvements were found in the MIO (P follow-up. Additionally, a significant...

  18. Cyclooxygenase-2 inhibitors and knee prosthesis surgery

    Meunier, Andreas

    2008-01-01

    Adverse effects of cyclooxygenase (COX) inhibitors on bone healing have previously been demonstrated in diaphyseal fracture models in animals. In spite of that, they are widely used as postoperative analgesics in orthopaedic surgery. After joint replacement, a bone repair process starts at the interface between bone and cement. If this process is disturbed, the prosthesis may never become rigidly fixed to the bone, leading to migration and with time loosening. This thesis investigates the eff...

  19. 3D reconstruction of bony elements of the knee joint and finite element analysis of total knee prosthesis obtained from the reconstructed model.

    Djoudi, Farid

    2013-01-01

    Two separate themes are presented in this paper. The first theme is to present a graphical modeling approach of human anatomical structures namely, the femur and the tibia. The second theme involves making a finite element analysis of stresses, displacements and deformations in prosthetic implants (the femoral implant and the polyethylene insert). The graphical modeling approach comes in two parts. The first is the segmentation of MRI scanned images, retrieved in DICOM format for edge detection. In the second part, 3D-CAD models are generated from the results of the segmentation stage. The finite element analysis is done by first extracting the prosthetic implants from the reconstructed 3D-CAD model, then do a finite element analysis of these implants under objectively determined conditions such as; forces, allowed displacements, the materials composing implant, and the coefficient of friction. The objective of this work is to implement an interface for exchanging data between 2D MRI images obtained from a medical diagnosis of a patient and the 3D-CAD model used in various applications, such as; the extraction of the implants, stress analysis at the knee joint and can serve as an aid to surgery, also predict the behavior of the prosthetic implants vis-a-vis the forces acting on the knee joints.

  20. High performance 3-coil wireless power transfer system for the 512-electrode epiretinal prosthesis.

    Zhao, Yu; Nandra, Mandheerej; Yu, Chia-Chen; Tai, Yu-chong

    2012-01-01

    The next-generation retinal prostheses feature high image resolution and chronic implantation. These features demand the delivery of power as high as 100 mW to be wireless and efficient. A common solution is the 2-coil inductive power link, used by current retinal prostheses. This power link tends to include a larger-size extraocular receiver coil coupled to the external transmitter coil, and the receiver coil is connected to the intraocular electrodes through a trans-sclera trans-choroid cable. In the long-term implantation of the device, the cable may cause hypotony (low intraocular pressure) and infection. However, when a 2-coil system is constructed from a small-size intraocular receiver coil, the efficiency drops drastically which may induce over heat dissipation and electromagnetic field exposure. Our previous 2-coil system achieved only 7% power transfer. This paper presents a fully intraocular and highly efficient wireless power transfer system, by introducing another inductive coupling link to bypass the trans-sclera trans-choroid cable. With the specific equivalent load of our customized 512-electrode stimulator, the current 3-coil inductive link was measured to have the overall power transfer efficiency around 36%, with 1-inch separation in saline. The high efficiency will favorably reduce the heat dissipation and electromagnetic field exposure to surrounding human tissues. The effect of the eyeball rotation on the power transfer efficiency was investigated as well. The efficiency can still maintain 14.7% with left and right deflection of 30 degree during normal use. The surgical procedure for the coils' implantation into the porcine eye was also demonstrated.

  1. Chairmen Joint Chiefs of Staff's Leadership Using the Joint Strategic Planning System in the 1990s: Recommendations for Strategic Leaders

    Meinhart, Richard

    2003-01-01

    This monograph examines how the three Chairmen of the Joint Chiefs of Staff adapted and used the Joint Strategic Planning System from 1990 to 2000 to provide advice to the Secretary of Defense and to the...

  2. Advantages of externally powered prosthesis with feedback system using pseudo-cineplasty.

    Nambu, Seiji; Ikebuchi, Mitsuhiko; Taniguchi, Masashi; Park, Choong Sik; Kitagawa, Takahiro; Nakajima, Shigeyoshi; Koike, Tatsuya

    2014-01-01

    Externally powered upper-limb prostheses are difficult to use because of the lack of sensory feedback. Neuroprostheses have recently been developed for people with upper-limb amputation but are complicated, expensive, and still developing. We therefore designed a simple system by combining pseudo-cineplasty with extended physiological proprioception to provide sensory feedback to the body. We penetrated the palmaris longus tendon percutaneously with a metal ring, similar to that used in body piercing, in a nondisabled subject as a pseudo-cineplasty. The tendon and ring were connected to the system, and a sensory feedback experiment was performed. We investigated the ability of the user to determine the size of an object grasped by the prosthetic hand without visual information. The subject could distinguish between large and small objects with 100% accuracy and between small, medium, and large objects with 80% accuracy. In pseudo-cineplasty, control and sensory feedback are natural because the prosthetic hand is controlled by muscle contraction. Tension transmitted from the prosthetic hand is sensed via muscle spindles and skin sensors. This technique allows only partial sensory feedback but appears to offer several advantages over other human-machine interfaces.

  3. Joint C4ISR Architecture Planning/Analysis System (JCAPS)

    Wostbrock, Bill

    2002-01-01

    The contractor satisfactorily completed all tasks under both efforts, providing the technology and technical expertise in the development of the Joint C4ISR Architecture Planning/Analysis System (JCAPS) Database Tool...

  4. Pelamis WEC - full-scale joint system test

    Yemm, R.

    2003-07-01

    This report describes the building and testing of a full-scale Pelamis Wave Energy Converter (WEC) two-axis joint system using a laboratory joint test rig. The main project objective to develop an intermediate demonstration model to confirm full scale control, hydraulic and data acquisition systems is discussed, and the key objectives of the programme are listed. Details are given of the semi-submerged articulated structure of cylindrical elements linked by hinged joints, and the integrated testing of all key components. A summary of the work programme and a description of the test rig are presented.

  5. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    Miller LE

    2014-05-01

    Full Text Available Larry E Miller,1,2 Jon E Block21Miller Scientific Consulting, Inc., Asheville, NC, USA; 2The Jon Block Group, San Francisco, CA, USA Abstract: Chronic sacroiliac (SI joint-related low back pain (LBP is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry® SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed. Keywords: arthrodesis, fusion, minimally invasive, sacroiliac, SImmetry

  6. Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.

    Montenegro, Alexandre Campos; Machado, Aldir Nascimento; Depes Gouvêa, Cresus Vinicius

    2008-12-01

    The aim of this in vitro study was to evaluate the tensile strength of titanium cylinders cemented on stainless steel abutment mock-ups by the Cerazone system. Four types of cements were used: glass ionomer, Fuji I (GC); zinc phosphate, Cimento LS (Vigodent); zinc oxide without eugenol, Rely x Temp NE (3M ESPE); and resin cement, Rely x ARC (3M ESPE). Four experimental groups were formed, each composed of 5 test specimens. Each test specimen consisted of a set of 1 cylinder and 1 stainless steel abutment mock-up. All cements tested were manipulated in accordance with manufacturers' instructions. A static load of 5 Newtons (N) for 2 minutes was used to standardize the procedure. The tensile tests were performed by a mechanical universal testing machine (EMIC DL500MF) at a crosshead speed of 0.5 mm/min. The highest bonding values resulting from the experiment were obtained by Cimento LS (21.86 MPa mean), followed by the resin cement Rely x ARC (12.95 MPa mean), Fuji I (6.89 MPa mean), and Rely x Temp NE (4.71 MPa mean). The results were subjected to analysis of variance (ANOVA) and the Student's t test. The cements differed amongst them as regards tensile strength, with the highest bonding levels recorded with zinc phosphate (Cimento LS) and the lowest with the zinc oxide without eugenol (Rely x Temp NE).

  7. Loop containment (joint integrity) assessment Brayton Isotope Power System flight system

    1976-01-01

    The Brayton Isotope Power System (BIPS) contains a large number of joints. Since the failure of a joint would result in loss of the working fluid and consequential failure of the BIPS, the integrity of the joints is of paramount importance. The reliability of the ERDA BIPS loop containment (joint integrity) is evaluated. The conceptual flight system as presently configured is depicted. A brief description of the flight system is given

  8. Effect of aqueous solution and load on the formation of DLC transfer layer against Co-Cr-Mo for joint prosthesis.

    Guo, Feifei; Zhou, Zhifeng; Hua, Meng; Dong, Guangneng

    2015-09-01

    Diamond-like carbon (DLC) coating exhibits excellent mechanical properties such as high hardness, low friction and wear, which offer a promising solution for the metal-on-metal hip joint implants. In the study, the hydrogen-free DLC coating with the element Cr as the interlay addition was deposited on the surface of the Co-Cr-Mo alloy by a unbalanced magnetron sputtering method. The coating thickness was controlled as 2 µm. Nano-indentation test indicated the hardness was about 13 GPa. DLC coated Co-Cr-Mo alloy disc against un-coated Co-Cr-Mo alloy pin (spherical end SR9.5) comprised the friction pairs in the pin-on-disc tribotest under bovine serum albumin solution (BSA) and physiological saline(PS).The tribological behavior under different BSA concetrations(2-20 mg/ml), and applied load (2-15N) was investigated.DLC transfer layer did not form under BSA solution, even though different BSA concetration and applied load changed. The coefficient of friction(COF) under 6 mg/ml BSA at 10 N was the lowest as 0.10. A higher COF of 0.13 was obtained under 20 mg/ml BSA. The boundary absorption layer of protein is the main factor for the counterparts. However, the continous DLC transfer layer was observed under PS solution, which make a lower COF of 0.08. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Joint design of QC-LDPC codes for coded cooperation system with joint iterative decoding

    Zhang, Shunwai; Yang, Fengfan; Tang, Lei; Ejaz, Saqib; Luo, Lin; Maharaj, B. T.

    2016-03-01

    In this paper, we investigate joint design of quasi-cyclic low-density-parity-check (QC-LDPC) codes for coded cooperation system with joint iterative decoding in the destination. First, QC-LDPC codes based on the base matrix and exponent matrix are introduced, and then we describe two types of girth-4 cycles in QC-LDPC codes employed by the source and relay. In the equivalent parity-check matrix corresponding to the jointly designed QC-LDPC codes employed by the source and relay, all girth-4 cycles including both type I and type II are cancelled. Theoretical analysis and numerical simulations show that the jointly designed QC-LDPC coded cooperation well combines cooperation gain and channel coding gain, and outperforms the coded non-cooperation under the same conditions. Furthermore, the bit error rate performance of the coded cooperation employing jointly designed QC-LDPC codes is better than those of random LDPC codes and separately designed QC-LDPC codes over AWGN channels.

  10. An analysis of observer-rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years.

    Geruschat, Duane R; Richards, Thomas P; Arditi, Aries; da Cruz, Lyndon; Dagnelie, Gislin; Dorn, Jessy D; Duncan, Jacque L; Ho, Allen C; Olmos de Koo, Lisa C; Sahel, José-Alain; Stanga, Paulo E; Thumann, Gabriele; Wang, Vizhong; Greenberg, Robert J

    2016-05-01

    The purpose of this analysis was to compare observer-rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. The Functional Low-Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow-up of 36 months. FLORA is a multi-component instrument that consists in part of observer-rated assessment of 35 tasks completed with the device ON versus OFF. The ease with which a patient completes a task is scored using a four-point scale, ranging from easy (score of 1) to impossible (score of 4). The tasks are evaluated individually and organised into four discrete domains, including 'Visual orientation', 'Visual mobility', 'Daily life and 'Interaction with others'. Twenty-six patients completed each of the 35 tasks. Overall, 24 out of 35 tasks (69 per cent) were statistically significantly easier to achieve with the device ON versus OFF. In each of the four domains, patients' performances were significantly better (p vision-related tasks with the device ON versus OFF. © 2016 The Authors Clinical and Experimental Optometry published by John Wiley & Sons Australia, Ltd on behalf of Optometry Australia.

  11. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  12. A comparative evaluation of linear dimensional accuracy of the dies obtained using three conceptually different die systems in the fabrication of implant prosthesis: An in vitro study

    Manawar Ahmad

    2014-01-01

    Purpose: The purpose of the study was to evaluate the linear dimensional accuracy between the implant master die and three conceptually different die systems such as Pindex system, Accu-trac precision die system, and Conventional brass dowel pin system. Materials and Methods: Thirty impressions of implant master die were made with polyether impression material. Ten experimental implant casts were fabricated for each of the three different die systems tested: Accu-trac precision die tray system, Pindex system, and conventional brass dowel pin system. The solid experimental casts were sectioned and then removed from the die system 30 times. Linear distances between all six possible distances were measured from one centre of the transfer coping to the other, using a co-ordinate measuring machine in millimeters up to accuracy of 0.5 microns. Data were tabulated and statistically analyzed by Binomial non parametric test using SPSS version 15. Results: Significant differences were found for distance A-B (P = 0.002, A-C ( P = 0.002, A-D (P value = 0.002, and B-D ( P = 0.021 in Conventional Dowel pin system however for Accu-trac precision die tray system, it was significant only for distance A-D (P = 0.002 but for Pindex system it was non-significant for all the distances measured. Conclusion: Within the limitations of this study, use of Pindex system is recommended when sectioned dies are needed for a multi implant retained prosthesis.

  13. Control system for a multi-joint inspection robot

    Asano, K.

    1984-01-01

    Remote systems, in which a human operator in a safe zone determines pertinent circumstances and makes decisions on work procedures, while a robot does direct work in hazardous environments, have been becoming more and more important in accordance with the increase in nuclear facilities. In such remote systems, to perform tasks which are merely ambiguously defined beforehand, it is very important that the systems have the ability to execute desired tasks easily and immediately without any programming or teaching work on the spot. A control system, named Self Approach System (SAS), for a multi-joint inspection robot has been developed as a key component in a remote inspection system for use in physically difficult or dangerous environments. It has 8 joints and 17 degrees-of-freedom and was designed taking many of the above points into account. This paper describes SAS details

  14. Joint Sustainment of Weapon Systems. Would We Be Better Off?

    Hall, Richard A

    2006-01-01

    .... As depots within the military begin to implement new procedures based on the Lean Six Sigma model, a proposed consolidation of efforts based on major weapon systems could lead to improved cost benefits and decreased maintenance time. Tied with the current Joint Depot Maintenance Program, Lean Six Sigma can continue to improve the Service's depot performance.

  15. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  16. Kinematic analysis of a posterior-stabilized knee prosthesis.

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  17. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Zhi-Xin Zhao

    2015-01-01

    Full Text Available Background: The goal of total knee arthroplasty (TKA is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Results: Both the output data trends and the measured values derived from the normal knee′s kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  18. Joint Decoding of Concatenated VLEC and STTC System

    Chen Huijun

    2008-01-01

    Full Text Available Abstract We consider the decoding of wireless communication systems with both source coding in the application layer and channel coding in the physical layer for high-performance transmission over fading channels. Variable length error correcting codes (VLECs and space time trellis codes (STTCs are used to provide bandwidth efficient data compression as well as coding and diversity gains. At the receiver, an iterative joint source and space time decoding scheme are developed to utilize redundancy in both STTC and VLEC to improve overall decoding performance. Issues such as the inseparable systematic information in the symbol level, the asymmetric trellis structure of VLEC, and information exchange between bit and symbol domains have been considered in the maximum a posteriori probability (MAP decoding algorithm. Simulation results indicate that the developed joint decoding scheme achieves a significant decoding gain over the separate decoding in fading channels, whether or not the channel information is perfectly known at the receiver. Furthermore, how rate allocation between STTC and VLEC affects the performance of the joint source and space-time decoder is investigated. Different systems with a fixed overall information rate are studied. It is shown that for a system with more redundancy dedicated to the source code and a higher order modulation of STTC, the joint decoding yields better performance, though with increased complexity.

  19. Joint Decoding of Concatenated VLEC and STTC System

    Huijun Chen

    2008-07-01

    Full Text Available We consider the decoding of wireless communication systems with both source coding in the application layer and channel coding in the physical layer for high-performance transmission over fading channels. Variable length error correcting codes (VLECs and space time trellis codes (STTCs are used to provide bandwidth efficient data compression as well as coding and diversity gains. At the receiver, an iterative joint source and space time decoding scheme are developed to utilize redundancy in both STTC and VLEC to improve overall decoding performance. Issues such as the inseparable systematic information in the symbol level, the asymmetric trellis structure of VLEC, and information exchange between bit and symbol domains have been considered in the maximum a posteriori probability (MAP decoding algorithm. Simulation results indicate that the developed joint decoding scheme achieves a significant decoding gain over the separate decoding in fading channels, whether or not the channel information is perfectly known at the receiver. Furthermore, how rate allocation between STTC and VLEC affects the performance of the joint source and space-time decoder is investigated. Different systems with a fixed overall information rate are studied. It is shown that for a system with more redundancy dedicated to the source code and a higher order modulation of STTC, the joint decoding yields better performance, though with increased complexity.

  20. Joint involvement in patients affected by systemic lupus erythematosus: application of the swollen to tender joint count ratio

    E. Cipriano

    2015-09-01

    Full Text Available Joint involvement is a common manifestation in systemic lupus erythematosus (SLE. According to the SLE disease activity index 2000 (SLEDAI-2K, joint involvement is present in case of ≥2 joints with pain and signs of inflammation. However this definition could fail to catch all the various features of joint involvement. Alternatively the Swollen to Tender joint Ratio (STR could be used. This new index, which was originally proposed for rheumatoid arthritis (RA patients, is based on the count of 28 swollen and tender joints. Our study is, therefore, aimed to assess joint involvement in a SLE cohort using the STR. SLE patients with joint symptoms (≥1 tender joint were enrolled over a period of one month. Disease activity was assessed by SLEDAI-2K. We performed the swollen and tender joint count (0-28 and calculated the STR. Depending on the STR, SLE patients were grouped into three categories of disease activity: low (STR1.0. We also calculated the disease activity score based on a 28-joint count and the erythrocyte sedimentation rate (DAS28-ESR. We enrolled 100 SLE patients [F/M 95/5, mean±standard deviation (SD age 46.3±10.6 years, mean±SD disease duration 147.1±103.8 months]. The median of tender and swollen joints was 4 (IQR 7 and 1 (IQR 2.5, respectively. The median STR value was 0.03 (IQR 0.6. According to the STR, disease activity was low in 70 patients, moderate in 23 and high in 7. A significant correlation was identified between STR values and DAS28 (r=0.33, p=0.001. The present study suggests a correlation between STR and DAS28, allowing an easier and faster assessment of joint involvement with the former index.

  1. Reading visual braille with a retinal prosthesis.

    Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.

  2. Characteristics of joint involvement and relationships with systemic inflammation in systemic sclerosis

    Avouac, Jerome; Walker, Ulrich; Tyndall, Alan

    2010-01-01

    To determine the prevalence of and independent factors associated with joint involvement in a large population of patients with systemic sclerosis (SSc).......To determine the prevalence of and independent factors associated with joint involvement in a large population of patients with systemic sclerosis (SSc)....

  3. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health.

    Hersek, Sinan; Toreyin, Hakan; Teague, Caitlin N; Millard-Stafford, Mindy L; Jeong, Hyeon-Ki; Bavare, Miheer M; Wolkoff, Paul; Sawka, Michael N; Inan, Omer T

    2017-10-01

    We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Five separate experiments were performed to demonstrate the: 1) ability of the EBI system to assess knee injury and recovery; 2) interday variability of knee EBI measurements; 3) sensitivity of the system to small changes in interstitial fluid volume; 4) reducing the error of EBI measurements using acceleration signals; and 5) use of the system with dry electrodes integrated to a wearable knee wrap. 1) The absolute difference in resistance ( R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p knee R was 2.5 Ω and for X was 1.2 Ω. 3) Local heating/cooling resulted in a significant decrease/increase in knee R (p knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated ( R 2 = 0.8 and 0.9, respectively). This study demonstrates the use of wearable EBI measurements in monitoring knee joint health. The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation.

  4. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  5. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report

    Gayatri Shankaran

    2016-08-01

    Full Text Available Rapid prototyping (RP is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D model created in a computer aided design (CAD system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the cranio-maxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  6. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  7. Joint compensation of multiple RF impairments in MIMO STBC systems

    Qi, Jian

    2011-09-01

    In this paper, we propose a compensation method for the joint effect of high-power amplifier (HPA) nonlinearity, in-phase/quadrature-phase (I/Q) imbalance and crosstalk in multiple-input multiple-output (MIMO) orthogonal space-time block coding (OSTBC) systems. The performance of the MIMO OSTBC equipped with the proposed compensation mechanism is evaluated in terms of average symbol error probability and system capacity, in Rayleigh fading channels. Numerical results are provided and show the effects on performance of several system parameters, namely, the HPA parameters, image-leakage ratio, crosstalk, numbers of antennas, and phase-shift keying modulation order. © 2011 IEEE.

  8. Joint Transmitter-Receiver Optimization in the Downlink CDMA Systems

    Mohammad Saquib

    2002-08-01

    Full Text Available To maximize the downlink code-division multiple access (CDMA system capacity, we propose to minimize the total transmitted power of the system subject to users′ signal-to-interference ratio (SIR requirements via designing optimum transmitter sequences and utilizing linear optimum receivers (minimum mean square error (MMSE receiver. In our work on joint transmitter-receiver design for the downlink CDMA systems with multiple antennas and multipath channels, we develop several optimization algorithms by considering various system constraints and prove their convergence. We empirically observed that under the optimization algorithm with no constraint on the system, the optimum receiver structure matches the received transmitter sequences. A simulation study is performed to see how the different practical system constraints penalize the system with respect to the optimum algorithm with no constraint on the system.

  9. Full Scale 3D Preoperative Planning System of the Ankle Joint Replacement Surgery with Multimedia System

    Shuh-Ping Sun

    2014-05-01

    Full Text Available This study is intended to develop a computer-aided pre-surgical planning and simulating system in a multimedia environment for ankle joint replacement surgery. This system uses full-scale 3D reverse engineering techniques in design and development of the pre-surgical planning modules for ankle joint replacement surgery. This planning system not only develops the real-scale 3D image of the artificial ankle joint but also provides a detailed interior measurement of the ankle joint from various cutting planes. In this study, we apply the multimedia user interface to integrate different software functions into a surgical planning system with integrated functions. The functions include 3D model image acquisition, cutting, horizontal shifting and rotation of related bones (tibia and talus of the ankle joint in the predetermined time. For related bones of the ankle joint, it can also be used to design artificial ankle joints for adults in Taiwan. Those planning procedures can be recorded in this system for further research and investigation. Furthermore, since this system is a multimedia user interface, surgeons can use this system to plan and find a better and more efficient surgical approach before surgery. A database is available for this system to update and expand, which can provide different users with clinical cases as per their experience and learning.

  10. Joint Fire Support in 2020: Development of a Future Joint Fires Systems Architecture for Immediate, Unplanned Targets

    Gabriel, J. T; Bartel, Matthew; Dorrough, Grashawn J; Paiz, B. L; Peters, Brian; Savage, Matthew; Nordgran, Spencer

    2006-01-01

    ... in support of the commander. In this context, the Joint Fire Support in 2020 project applied systems engineering procedures and principles to develop functional, physical, and operational architectures that maximize rapid...

  11. VARIABLE STIFFNESS HAND PROSTHESIS: A SYSTEMATIC REVIEW

    S. Cecilia Tapia-Siles

    2017-06-01

    Full Text Available Prosthetics is an important field in engineering due to the large number of amputees worldwide and the associated problems such as limited functionality of the state of the art. An important functionality of the human hand is its capability of adjusting the stiffness of the joints depending on the currently performed task. For the development of new technology it is important to understand the limitations of existing resources. As part of our efforts to develop a variable stiffness grasper for developing countries a systematic review was performed covering technology of body powered and myoelectric hand prosthesis. Focus of the review is readiness of prosthetic hands regarding their capability of controlling the stiffness of the end effector. Publications sourced through three different digital libraries were systematically reviewed on the basis of the PRISMA standard. We present a search strategy as well as the PRISMA assessment of the resulting records which covered 321 publications. The records were assessed and the results are presented for the ability of devices to control their joint stiffness. The review indicates that body powered prosthesis are preferred to myoelectric hands due to the reduced cost, the simplicity of use and because of their inherent ability to provide feedback to the user. Stiffness control was identified but has not been fully covered in the current state of the art. In addition we summarise the identified requirements on prosthetic hands as well as related information which can support the development of new prosthetics.

  12. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  13. Design of Embedded System for Multivariate Classification of Finger and Thumb Movements Using EEG Signals for Control of Upper Limb Prosthesis

    Javed, Amna; Tiwana, Mohsin I.; Khan, Umar Shahbaz

    2018-01-01

    Brain Computer Interface (BCI) determines the intent of the user from a variety of electrophysiological signals. These signals, Slow Cortical Potentials, are recorded from scalp, and cortical neuronal activity is recorded by implanted electrodes. This paper is focused on design of an embedded system that is used to control the finger movements of an upper limb prosthesis using Electroencephalogram (EEG) signals. This is a follow-up of our previous research which explored the best method to classify three movements of fingers (thumb movement, index finger movement, and first movement). Two-stage logistic regression classifier exhibited the highest classification accuracy while Power Spectral Density (PSD) was used as a feature of the filtered signal. The EEG signal data set was recorded using a 14-channel electrode headset (a noninvasive BCI system) from right-handed, neurologically intact volunteers. Mu (commonly known as alpha waves) and Beta Rhythms (8–30 Hz) containing most of the movement data were retained through filtering using “Arduino Uno” microcontroller followed by 2-stage logistic regression to obtain a mean classification accuracy of 70%. PMID:29888252

  14. Design of Embedded System for Multivariate Classification of Finger and Thumb Movements Using EEG Signals for Control of Upper Limb Prosthesis

    Nasir Rashid

    2018-01-01

    Full Text Available Brain Computer Interface (BCI determines the intent of the user from a variety of electrophysiological signals. These signals, Slow Cortical Potentials, are recorded from scalp, and cortical neuronal activity is recorded by implanted electrodes. This paper is focused on design of an embedded system that is used to control the finger movements of an upper limb prosthesis using Electroencephalogram (EEG signals. This is a follow-up of our previous research which explored the best method to classify three movements of fingers (thumb movement, index finger movement, and first movement. Two-stage logistic regression classifier exhibited the highest classification accuracy while Power Spectral Density (PSD was used as a feature of the filtered signal. The EEG signal data set was recorded using a 14-channel electrode headset (a noninvasive BCI system from right-handed, neurologically intact volunteers. Mu (commonly known as alpha waves and Beta Rhythms (8–30 Hz containing most of the movement data were retained through filtering using “Arduino Uno” microcontroller followed by 2-stage logistic regression to obtain a mean classification accuracy of 70%.

  15. Design of Embedded System for Multivariate Classification of Finger and Thumb Movements Using EEG Signals for Control of Upper Limb Prosthesis.

    Rashid, Nasir; Iqbal, Javaid; Javed, Amna; Tiwana, Mohsin I; Khan, Umar Shahbaz

    2018-01-01

    Brain Computer Interface (BCI) determines the intent of the user from a variety of electrophysiological signals. These signals, Slow Cortical Potentials, are recorded from scalp, and cortical neuronal activity is recorded by implanted electrodes. This paper is focused on design of an embedded system that is used to control the finger movements of an upper limb prosthesis using Electroencephalogram (EEG) signals. This is a follow-up of our previous research which explored the best method to classify three movements of fingers (thumb movement, index finger movement, and first movement). Two-stage logistic regression classifier exhibited the highest classification accuracy while Power Spectral Density (PSD) was used as a feature of the filtered signal. The EEG signal data set was recorded using a 14-channel electrode headset (a noninvasive BCI system) from right-handed, neurologically intact volunteers. Mu (commonly known as alpha waves) and Beta Rhythms (8-30 Hz) containing most of the movement data were retained through filtering using "Arduino Uno" microcontroller followed by 2-stage logistic regression to obtain a mean classification accuracy of 70%.

  16. Metabolics of stair ascent with a powered transfemoral prosthesis.

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  17. Expansion joint for guideway for magnetic levitation transportation system

    Rossing, T.D.

    1993-02-09

    An expansion joint that allows a guideway of a magnetic levitation transportation system to expand and contract while minimizing transients occurring in the magnetic lift and drag forces acting on a magnetic levitation vehicle traveling over the joint includes an upper cut or recess extending downwardly from the upper surface of the guideway and a non-intersecting lower cut or recess that extends upwardly from the lower surface of the guideway. The side walls of the cuts can be parallel to each other and the vertical axis of the guideway; the depth of the lower cut can be greater than the depth of the upper cut; and the overall combined lengths of the cuts can be greater than the thickness of the guideway from the upper to lower surface so that the cuts will overlap, but be spaced apart from each other. The distance between the cuts can be determined on the basis of the force transients and the mechanical behavior of the guideway. A second pair of similarly configured upper and lower cuts may be disposed in the guideway; the expansion joint may consist of two upper cuts and one lower cut; or the cuts may have non-parallel, diverging side walls so that the cuts have a substantially dove-tail shape.

  18. Integrated High-Speed Torque Control System for a Robotic Joint

    Davis, Donald R. (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Valvo, Michael C. (Inventor); Askew, R. Scott (Inventor)

    2013-01-01

    A control system for achieving high-speed torque for a joint of a robot includes a printed circuit board assembly (PCBA) having a collocated joint processor and high-speed communication bus. The PCBA may also include a power inverter module (PIM) and local sensor conditioning electronics (SCE) for processing sensor data from one or more motor position sensors. Torque control of a motor of the joint is provided via the PCBA as a high-speed torque loop. Each joint processor may be embedded within or collocated with the robotic joint being controlled. Collocation of the joint processor, PIM, and high-speed bus may increase noise immunity of the control system, and the localized processing of sensor data from the joint motor at the joint level may minimize bus cabling to and from each control node. The joint processor may include a field programmable gate array (FPGA).

  19. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  20. Prosthesis-patient mismatch

    Philippe Pibarot

    2011-04-01

    Full Text Available Prosthesis-patient mismatch (PPM is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main hemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. The purpose of this review is to present an update on the present state of knowledge with regards to diagnosis, prognosis and prevention of PPM. PPM is a frequent occurrence (20%–70% of aortic valve replacements that has been shown to be associated with worse hemodynamics, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.

  1. Bioelectronic retinal prosthesis

    Weiland, James D.

    2016-05-01

    Retinal prosthesis have been translated to clinical use over the past two decades. Currently, two devices have regulatory approval for the treatment of retinitis pigmentosa and one device is in clinical trials for treatment of age-related macular degeneration. These devices provide partial sight restoration and patients use this improved vision in their everyday lives to navigate and to detect large objects. However, significant vision restoration will require both better technology and improved understanding of the interaction between electrical stimulation and the retina. In particular, current retinal prostheses do not provide peripheral visions due to technical and surgical limitations, thus limiting the effectiveness of the treatment. This paper reviews recent results from human implant patients and presents technical approaches for peripheral vision.

  2. [Multicentre study of infection incidence in knee prosthesis].

    Jaén, F; Sanz-Gallardo, M I; Arrazola, M P; García de Codes, A; de Juanes, A; Resines, C

    2012-01-01

    To determine the incidence of surgical site infection in knee prosthesis surgical procedure for a follow-up period of one year in twelve hospitals in Madrid region. A prospective study was carried out from January to December 2009 using a national surveillance system called Indicadores Clínicos de Mejora Continua de Calidad. Primary and revision knee joint replacements in patients operated on in the previous year were included. Criteria used to define surgical site infection and patient risk index categories were those established by the Centers for Disease Control and Prevention and National Nosocomial Infections Surveillance. The incidence rates were worked out crude and adjusted by hazard ratio. 2,088 knee prosthesis procedures were analyzed. The overall incidence of surgical site infection was 2.1%. Sixty-five percent of the infections were organ/space. Sixty percent of the infections were identified in the early postoperative period. Of all surgical site infections, 41.9% were microbiologically confirmed. Antibiotic prophylaxis was implemented correctly in 63.3% of the cases. The most important cause of inappropriate prophylaxis was an unsuitable duration in 85.7% of the cases. The presurgical preparation was carried out correctly in 50.3% of surgical operations. The incidence of knee arthroplasty infection was twice as high as in the National Healthcare Safety Network and similar to national rates. In this study, the incidence of infection was within the range of infection rates in other published European studies. Surveillance and control strategies of health care for associated infections allow us to assess trends and the impact of preventive measures. Copyright © 2011 SECOT. Published by Elsevier Espana. All rights reserved.

  3. Architecting Joint Command and Control System of System Capability Certifications

    Acosta, Jacob; Hoesly, Scot; Huseth, Scott; Krider, Steven; Lamb, Jeremy; Martin, Calvin; Medina, Vince; Medina, Jorge; Nguyen, Michael; Patel, Jaykant

    2007-01-01

    Command, Control, Communications, Computers, and Intelligence (C4I) systems, each originally designed to address a single warfighting function, have been assembled into an interdependent C4I System of Systems (SoS...

  4. The Urgent Need for a Comprehensive, Fully Integrated, Joint Intra-Theater Aeromedical Evacuation System

    2017-04-06

    the Middle East and Africa , it is critical for the Army’s Medical Department (AMEDD) and the Joint Staff continue to leverage joint patient...Service and a single Service would prevent the establishment of a watered -down, lowest-common-denominator AE system that would result from a joint...to provide quality enroute care to increase survivability rates and decrease long-term morbidity. The current joint intra-theater AE system lacks

  5. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  6. Joint optimization of regional water-power systems

    Cardenal, Silvio Javier Pereira; Mo, Birger; Gjelsvik, Anders

    2016-01-01

    using stochastic dual dynamic programming. The results showed that current water allocation to hydropower producers in basins with high irrigation productivity, and to irrigation users in basins with high hydropower productivity was sub-optimal. Optimal allocation was achieved by managing reservoirs...... for joint optimization of water and electric power systems was developed in order to identify methodologies to assess the broader interactions between water and energy systems. The proposed method is to include water users and power producers into an economic optimization problem that minimizes the cost...... of power production and maximizes the benefits of water allocation, subject to constraints from the power and hydrological systems. The method was tested on the Iberian Peninsula using simplified models of the seven major river basins and the power market. The optimization problem was successfully solved...

  7. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  8. Systemic Operational Design: Enhancing the Joint Operation Planning Process

    Delacruz, Victor J

    2007-01-01

    Operational level commanders and their staffs require relevant and current joint doctrine that articulates the critical function of operational design and its role in the Joint Operation Planning Process (JOPP...

  9. Candida infection of a prosthetic shoulder joint

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  10. Candida infection of a prosthetic shoulder joint

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  11. Analysis on Sealing Reliability of Bolted Joint Ball Head Component of Satellite Propulsion System

    Guo, Tao; Fan, Yougao; Gao, Feng; Gu, Shixin; Wang, Wei

    2018-01-01

    Propulsion system is one of the important subsystems of satellite, and its performance directly affects the service life, attitude control and reliability of the satellite. The Paper analyzes the sealing principle of bolted joint ball head component of satellite propulsion system and discuss from the compatibility of hydrazine anhydrous and bolted joint ball head component, influence of ground environment on the sealing performance of bolted joint ball heads, and material failure caused by environment, showing that the sealing reliability of bolted joint ball head component is good and the influence of above three aspects on sealing of bolted joint ball head component can be ignored.

  12. Work in Progress - Developing Joint Degrees through E-Learning Systems

    Aguirre Herrera, Sandra; Quemada Vives, Juan; Salvachúa Rodríguez, Joaquín

    2008-01-01

    The development of Joint Degrees is an important mechanism for opening higher education systems nationwide, adapting them to the international standard, and promoting quality assessment to a broader environment. Since e-Learning systems covers a wide range of academic programs, and as joint degrees such as e-Learning are rapidly growing trends, finding a suitable solution that enables universities to design joint degrees through their own e-Learning systems becomes necessary. This paper intro...

  13. Airborne and Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-421 Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) As of FY 2017...Information Program Name Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) DoD Component Army Responsible Office References SAR...UNCLASSIFIED 5 Mission and Description Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) products are software programmable

  14. Joint optimization of regional water-power systems

    Pereira-Cardenal, Silvio J.; Mo, Birger; Gjelsvik, Anders; Riegels, Niels D.; Arnbjerg-Nielsen, Karsten; Bauer-Gottwein, Peter

    2016-06-01

    Energy and water resources systems are tightly coupled; energy is needed to deliver water and water is needed to extract or produce energy. Growing pressure on these resources has raised concerns about their long-term management and highlights the need to develop integrated solutions. A method for joint optimization of water and electric power systems was developed in order to identify methodologies to assess the broader interactions between water and energy systems. The proposed method is to include water users and power producers into an economic optimization problem that minimizes the cost of power production and maximizes the benefits of water allocation, subject to constraints from the power and hydrological systems. The method was tested on the Iberian Peninsula using simplified models of the seven major river basins and the power market. The optimization problem was successfully solved using stochastic dual dynamic programming. The results showed that current water allocation to hydropower producers in basins with high irrigation productivity, and to irrigation users in basins with high hydropower productivity was sub-optimal. Optimal allocation was achieved by managing reservoirs in very distinct ways, according to the local inflow, storage capacity, hydropower productivity, and irrigation demand and productivity. This highlights the importance of appropriately representing the water users' spatial distribution and marginal benefits and costs when allocating water resources optimally. The method can handle further spatial disaggregation and can be extended to include other aspects of the water-energy nexus.

  15. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  16. Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis

    Paolo, J Di; Berli, M E; Campana, D M; Ubal, S; Cardenes, L D

    2007-01-01

    Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint

  17. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques.

    Lu, Minxun; Min, Li; Xiao, Cong; Li, Yongjiang; Luo, Yi; Zhou, Yong; Zhang, Wenli; Tu, Chongqi

    2018-01-01

    Currently, it is challenging to treat giant cell tumor (GCT) of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D)-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH) questionnaire and Mayo wrist scoring systems. The average follow-up was 14.45 months (range, 8-18 months). There was a significant decrease in the mean postoperative visual analog scale score (2.33) compared with the preoperative score (5.22; p 3D-printed prosthesis can be alternative options to treat Campanacci grade III or recurrent GCTs of distal radius and can result in short-term oncologic salvage, good postoperative function, and low complication rate. However, a long-term follow-up is required to determine the outcome.

  18. Design of a power-asymmetric actuator for a transtibial prosthesis.

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  19. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L.

    2004-01-01

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ( 18 F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  20. Wearable human body joint and posture measuring system

    Dunias, P.; Gransier, R.; Jin, A.; Statham, A.; Willems, P.

    2011-01-01

    In many medical applications, especially the orthopaedic setting, ambulatory, monitoring of human joint angles could be of substantial value to improving rehabilitation strategies and unravelling the pathomechanics of many degenerative joint diseases (e.g. knee osteoarthritis). With the ageing of

  1. Split-Framework in Mandibular Implant-Supported Prosthesis

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  2. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    Block, Jon; Miller,Larry

    2014-01-01

    Larry E Miller,1,2 Jon E Block21Miller Scientific Consulting, Inc., Asheville, NC, USA; 2The Jon Block Group, San Francisco, CA, USA Abstract: Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The...

  3. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.

    Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C

    2015-07-01

    Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. The Joint Capabilities Integration and Development System: Its Impact on Air Force Acquisition Thirteen Years Later

    2016-08-01

    PAROCHIALISM : OPERATIONAL REQUIREMENTS AND THE REQUIREMENTS GENERATION SYSTEM (RGS) ........................................................ 15 2003...SERVICE STOVEPIPES AND PAROCHIALISM : OPERATIONAL REQUIREMENTS AND THE REQUIREMENTS GENERATION SYSTEM (RGS) According to a 1974 General Accounting...The time had come to put aside service parochialism and self-interest and begin the march to joint capability development, joint concepts and

  6. Analysis of polyethylene terephthalate PET plastic bottle jointing system using finite element method (FEM)

    Zaidi, N. A.; Rosli, Muhamad Farizuan; Effendi, M. S. M.; Abdullah, Mohamad Hariri

    2017-09-01

    For almost all injection molding applications of Polyethylene Terephthalate (PET) plastic was analyzed the strength, durability and stiffness of properties by using Finite Element Method (FEM) for jointing system of wood furniture. The FEM was utilized for analyzing the PET jointing system for Oak and Pine as wood based material of furniture. The difference pattern design of PET as wood jointing furniture gives the difference value of strength furniture itself. The results show the wood specimen with grooves and eclipse pattern design PET jointing give lower global estimated error is 28.90%, compare to the rectangular and non-grooves wood specimen of global estimated error is 63.21%.

  7. Magnetically retained silicone facial prosthesis

    2013-06-09

    Jun 9, 2013 ... Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention.

  8. Elektra prosthesis for trapeziometacarpal osteoarthritis

    Klahn, A; Nygaard, Mads; Gvozdenovic, R

    2012-01-01

    We present a prospective follow-up of 39 Elektra prostheses in 37 patients (32 women and five men), with a mean age of 56.5 (range 46-71) years; 34 patients had osteoarthritis and three had rheumatoid arthritis. Patients were followed using clinical examination, including measurement of pain...... be the key problem in treating trapeziometacarpal osteoarthritis using a total prosthesis....

  9. Computational reverse shoulder prosthesis model: Experimental data and verification.

    Martins, A; Quental, C; Folgado, J; Ambrósio, J; Monteiro, J; Sarmento, M

    2015-09-18

    The reverse shoulder prosthesis aims to restore the stability and function of pathological shoulders, but the biomechanical aspects of the geometrical changes induced by the implant are yet to be fully understood. Considering a large-scale musculoskeletal model of the upper limb, the aim of this study is to evaluate how the Delta reverse shoulder prosthesis influences the biomechanical behavior of the shoulder joint. In this study, the kinematic data of an unloaded abduction in the frontal plane and an unloaded forward flexion in the sagittal plane were experimentally acquired through video-imaging for a control group, composed of 10 healthy shoulders, and a reverse shoulder group, composed of 3 reverse shoulders. Synchronously, the EMG data of 7 superficial muscles were also collected. The muscle force sharing problem was solved through the minimization of the metabolic energy consumption. The evaluation of the shoulder kinematics shows an increase in the lateral rotation of the scapula in the reverse shoulder group, and an increase in the contribution of the scapulothoracic joint to the shoulder joint. Regarding the muscle force sharing problem, the musculoskeletal model estimates an increased activity of the deltoid, teres minor, clavicular fibers of the pectoralis major, and coracobrachialis muscles in the reverse shoulder group. The comparison between the muscle forces predicted and the EMG data acquired revealed a good correlation, which provides further confidence in the model. Overall, the shoulder joint reaction force was lower in the reverse shoulder group than in the control group. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Joint time-frequency domain proportional fair scheduler with HARQ for 3GPP LTE systems

    Beh, KC; Doufexi, A; Armour, SMD

    2008-01-01

    This paper explores the potential gain of joint diversity in both frequency domain and time domain which can be exploited to achieve spectral efficiency gains whilst simultaneously facilitating QoS/ fairness in an OFDMA system particularly in 3GPP Long Term Evolution (LTE)). The performance of several joint time-frequency schedulers is investigated. Simulation results show that joint time frequency schedulers achieve significantly superior performance compared to a more conventional time doma...

  11. A new technique for repair of a dislocated sternoclavicular joint using a sternal tension cable system.

    Janson, Jacques T; Rossouw, Gawie J

    2013-02-01

    An unstable anterior or posterior sternoclavicular joint dislocation can cause severe morbidity with poor shoulder movement and strength. These dislocations need to be repaired, which can be challenging. Many different procedures have been described to obtain a stable joint fixation with varying results. We report a new technique for repairing a sternoclavicular joint dislocation by using a figure-of-eight sternal cable system. This procedure is relatively simple and reproducible to create a stable and functional sternoclavicular joint. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. The effects of load on system and lower-body joint kinetics during jump squats.

    Moir, Gavin L; Gollie, Jared M; Davis, Shala E; Guers, John J; Witmer, Chad A

    2012-11-01

    To investigate the effects of different loads on system and lower-body kinetics during jump squats, 12 resistance-trained men performed jumps under different loading conditions: 0%, 12%, 27%, 42%, 56%, 71%, and 85% of 1-repetition maximum (1-RM). System power output was calculated as the product of the vertical component of the ground reaction force and the vertical velocity of the bar during its ascent. Joint power output was calculated during bar ascent for the hip, knee, and ankle joints, and was also summed across the joints. System power output and joint power at knee and ankle joints were maximized at 0% 1-RM (p < 0.001) and followed the linear trends (p < 0.001) caused by power output decreasing as the load increased. Power output at the hip was maximized at 42% 1-RM (p = 0.016) and followed a quadratic trend (p = 0.030). Summed joint power could be predicted from system power (p < 0.05), while system power could predict power at the knee and ankle joints under some of the loading conditions. Power at the hip could not be predicted from system power. System power during loaded jumps reflects the power at the knee and ankle, while power at the hip does not correspond to system power.

  13. Verification of Strength of the Welded Joints by using of the Aramis Video System

    Pała Tadeusz

    2017-03-01

    Full Text Available In the paper are presented the results of strength analysis for the two types of the welded joints made according to conventional and laser technologies of high-strength steel S960QC. The hardness distributions, tensile properties and fracture toughness were determined for the weld material and heat affect zone material for both types of the welded joints. Tests results shown on advantage the laser welded joints in comparison to the convention ones. Tensile properties and fracture toughness in all areas of the laser joints have a higher level than in the conventional one. The heat affect zone of the conventional welded joints is a weakness area, where the tensile properties are lower in comparison to the base material. Verification of the tensile tests, which carried out by using the Aramis video system, confirmed this assumption. The highest level of strains was observed in HAZ material and the destruction process occurred also in HAZ of the conventional welded joint.

  14. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  15. Reconstrucción de la articulación temporomandibular postraumática con prótesis a medida: Planificación quirúrgica virtual Post-traumatic reconstruction with custom prosthesis of the temporomandibular joint: Computerized surgical planning

    Aitor García Sánchez

    2011-06-01

    surgical execution of three cases of bilateral articular ankylosis (6 joints is presented with simulation of osteotomies, maxillomandibular movements and custom total alloplastic prosthesis design for the temporomandibular joint. Conclusions: A comprehensive approach to articular biomechanics, intermaxillary relations and dental occlusion is necessary to obtain predictable and satisfactory results. Computer modeling and the use of custom alloplastic devices allows exact, safe total articular reconstruction.

  16. Cognitive Technologies: The Design of Joint Human-Machine Cognitive Systems

    Woods, David D.

    1985-01-01

    This article explores the implications of one type of cognitive technology, techniques and concepts to develop joint human-machine cognitive systems, for the application of computational technology by examining the joint cognitive system implicit in a hypothetical computer consultant that outputs some form of problem solution. This analysis reveals some of the problems can occur in cognitive system design-e.g., machine control of the interaction, the danger of a responsibility-authority doubl...

  17. Removable dental prosthesis as periodontal treatment method

    Aprilia Adenan

    2007-11-01

    Full Text Available The objectives of prostheses are to restore mastication force, improve esthetics and maintain gingival health. The construction and function of prosthesis restoration are mutually interdependent with condition of periodontal tissues. A properly constructed prosthesis is an integral phase of complete treatment of periodontal disease in order to maintain periodontal tissues health. This paper reports case of a man aged 47 years who came to Dental Specialist Clinic in Oral and Dental Hospital Faculty of Dentistry Universitas Padjadjaran with chief complaint of mobility in almost all his teeth and they seems to look longer. The patient has no systemic disease and did not want his teeth to be extracted. Clinical and panoramic radiographic and laboratoris examinations has been done. During treatment, oclusal adjustment and splinting had been done on tooth 33,34,35 and tooth 44,43 also tooth 43,42 splinting with composite. The following treatment was the acrylic removable partial denture for upper jaw while mandible was fitted a frame denture which functioned as a semi permanent splint. One month post treatment, patien felt comfort and the denture was well functioning.

  18. TOTAL ANKLE ARTHROPLASTY: BRAZILIAN EXPERIENCE WITH THE HINTEGRA PROSTHESIS.

    Nery, Caio; Fernandes, Túlio Diniz; Réssio, Cibele; Fuchs, Mauro Luiz; Godoy Santos, Alexandre Leme de; Ortiz, Rafael Trevisan

    2010-01-01

    Ankle arthrosis is becoming more and more common. The search for solutions that preserve joint function has led to a new generation of prosthesis with three components and more degrees of freedom. This paper presents the results achieved for ten patients treated with the HINTEGRA Prosthesis (Integra, New Deal), through collaborative action between the Foot and Ankle Groups of the Orthopedics and Traumatology divisions of Escola Paulista de Medicina, Unifesp, and the School of Medicine of the University of São Paulo (USP). The ten patients (six women and four men, aged between 29 and 66 years), underwent a surgical procedure consisting of Hintermann's technique, between January and June 2005. They were evaluated at prearranged intervals, and the data were subjected to statistical analysis. The surgery led to a significant improvement in ankle mobility. Radiological evaluation showed no signs of loosening or failure in the prosthetic components in any of the patients studied. Although the complication rate in our sample was high, it was equivalent to the rates found by other authors, and directly represents the learning curve associate with this kind of procedure. Four years after the procedure, it was found that the patients pain levels had significantly decreased, and that their functional patterns had significantly improved, with AOFAS and Hintermann scores indicating results that were excellent for 20%, good for 70% and poor for 10%. Treatment of ankle arthritis by means of total arthroplasty using the HINTEGRA prosthesis was capable of providing good results over an average observation period of four years.

  19. Dosimetry of a silicone breast prosthesis

    McGinley, P.H.; Powell, W.R.; Bostwick, J.

    1980-01-01

    Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of 60 Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material

  20. Malrotation of the McGhan Style 510 prosthesis.

    Schots, J.M.; Fechner, M.R.; Hoogbergen, M.M.; Tits, H.W.H.J.

    2010-01-01

    BACKGROUND: Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors

  1. The Cost of Jointness: Insights from Environmental Monitoring Systems in Low-Earth Orbit

    Dwyer, Morgan Maeve [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    This report summarizes the results of doctoral research that explored the cost impact of acquiring complex government systems jointly. The report begins by reviewing recent evidence that suggests that joint programs experience greater cost growth than non-joint programs. It continues by proposing an alternative approach for studying cost growth on government acquisition programs and demonstrates the utility of this approach by applying it to study the cost of jointness on three past programs that developed environmental monitoring systems for low-Earth orbit. Ultimately, the report concludes that joint programs' costs grow when the collaborating government agencies take action to retain or regain their autonomy. The report provides detailed qualitative and quantitative data in support of this conclusion and generalizes its findings to other joint programs that were not explicitly studied here. Finally, it concludes by presenting a quantitative model that assesses the cost impacts of jointness and by demonstrating how government agencies can more effectively architect joint programs in the future.

  2. Analysis of a retrieved delta III total shoulder prosthesis.

    Nyffeler, R W; Werner, C M L; Simmen, B R; Gerber, C

    2004-11-01

    A reversed Delta III total shoulder prosthesis was retrieved post-mortem, eight months after implantation. A significant notch was evident at the inferior pole of the scapular neck which extended beyond the inferior fixation screw. This bone loss was associated with a corresponding, erosive defect of the polyethylene cup. Histological examination revealed a chronic foreign-body reaction in the joint capsule. There were, however, no histological signs of loosening of the glenoid base plate and the stability of the prosthetic articulation was only slightly reduced by the eroded rim of the cup.

  3. Nasal prosthesis rehabilitation: a case report

    Jain, Sumeet; Maru, Kavita; Shukla, Jyotsana

    2011-01-01

    Facial defects resulting from neoplasm, congenital malformation or trauma can be restored with facial prosthesis using different materials and retention methods to achieve life-like look and function. A nasal prosthesis can re-establish esthetic form and anatomic contours for mid-facial defects...... the non-surgical rehabilitation, with polymethyl meth-acrylate resin, nasal prosthesis for a patient who received partial rhinectomy as a result of squamous cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of the patient with a mechanical retained design using...

  4. Oral splint for temporomandibular joint disorders with revolutionary fluid system

    Rahul Srivastava

    2013-01-01

    Full Text Available Temporomandibular joint (TMJ diseases and disorders refer to a complex and poorly understood set of conditions, manifested by pain in the area of the jaw and associated muscles and limitations in the ability to make the normal movements of speech, facial expression, eating, chewing, and swallowing. The conventional soft occlusal splint therapy is a much safer and effective mode of a conservative line of therapy in comparison to the surgical therapy for temporomandibular joint disorders (TMD. The purpose of this article is to review the Aqualizer TM , an hydrostatic oral splint, as accurate, effective treatment and differential diagnostic tool in TMD that allow treating the patient′s pain quickly and accurately saving valuable treatment time. The review article has been prepared doing a literature review from the world-wide web and pubmed/medline.

  5. Joint Polar Satellite System (JPSS) Common Ground System (CGS) Current Technical Performance Measures

    Cochran, S.; Panas, M.; Jamilkowski, M. L.; Miller, S. W.

    2015-12-01

    ABSTRACT The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). The Joint Polar Satellite System will replace the afternoon orbit component and ground processing system of the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA. The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological and geophysical observations of the Earth. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS). Developed and maintained by Raytheon Intelligence, Information and Services (IIS), the CGS is a multi-mission enterprise system serving NOAA, NASA and their national and international partners. The CGS has demonstrated its scalability and flexibility to incorporate multiple missions efficiently and with minimal cost, schedule and risk, while strengthening global partnerships in weather and environmental monitoring. The CGS architecture is being upgraded to Block 2.0 in 2015 to "operationalize" S-NPP, leverage lessons learned to date in multi-mission support, take advantage of more reliable and efficient technologies, and satisfy new requirements and constraints in the continually evolving budgetary environment. To ensure the CGS meets these needs, we have developed 49 Technical Performance Measures (TPMs) across 10 categories, such as data latency, operational availability and scalability. This paper will provide an overview of the CGS Block 2.0 architecture, with particular focus on the 10 TPM categories listed above. We will provide updates on how we ensure the deployed architecture meets these TPMs to satisfy our multi-mission objectives with the deployment of Block 2.0.

  6. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    Tesfa, B; Horler, G; Thobiani, F Al; Gu, F; Ball, A D

    2012-01-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. 1. Sense changes in the clamping force of the joint and report this fact. 2. Provide compatibility with the large dynamic range of clamping force. 3. Satisfy the limitations in terms of physical size. 4. Provide the means to electronically interface with the washer. 5. Provide a means of powering the washer in situ. 6. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show

  7. A novel adaptive joint power control algorithm with channel estimation in a CDMA cellular system

    2005-01-01

    Joint power control has advantages of multi-user detection and power control; and it can combat the multi-access interference and the near-far problem. A novel adaptive joint power control algorithm with channel estimation in a CDMA cellular system was designed. Simulation results show that the algorithm can control the power not only quickly but also precisely with a time change. The method is useful for increasing system capacity.

  8. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  9. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  10. Simulating Dynamics of the System of Articulated Rigid Bodies with Joint Friction

    M. V. Michaylyuk

    2016-01-01

    Full Text Available The subject of the work is to simulate dynamics of the system of articulated rigid bodies in the virtual environment complexes. The work aim is to develop algorithms and methods to simulate the multi-body system dynamics with joint friction to ensure all calculations in real time in line with visual realistic behavior of objects in a scene.The paper describes the multibody system based on a maximal set of coordinates, and to simulate the joint friction is used a Coulomb's law of dry friction. Joints are described using the holonomic constraints and their derivatives that specify the constraints on velocities of joined bodies. Based on The Coulomb’s law a correlation for the friction impulse values has been derived as an inequality. If the friction impulse performs a constraint that is a lack of relative motion of two joint-joined bodies, there is a static friction in the joint. Otherwise, there is a dynamic friction in the joint. Using a semi-implicit Euler method allows us to describe dynamics of articulated rigid bodies with joint friction as a system of linear algebraic equations and inequalities for the unknown velocities and impulse values.To solve the obtained system of equations and inequalities is used an iterative method of sequential impulses, which sequentially processes constraints for each joint with impulse calculation and its application to the joined bodies rather than considers the entire system. To improve the method convergence, at each iteration the calculated impulses are accumulated for their further using as an initial approximation at the next step of simulation.The proposed algorithms and methods have been implemented in the training complex dynamics subsystem, developed in SRISA RAS. Evaluation of these methods and algorithms has demonstrated their full adequacy to requirements for virtual environment systems and training complexes.

  11. Optimised robot-based system for the exploration of elastic joint properties.

    Frey, M; Burgkart, R; Regenfelder, F; Riener, R

    2004-09-01

    Numerous publications provide measured biomechanical data relating to synovial joints. However, in general, they do not reflect the non-linear elastic joint properties in detail or do not consider all degrees of freedom (DOF), or the quantity of data is sparse. To perform more comprehensive, extended measurements of elastic joint properties, an optimised robot-based approach was developed. The basis was an industrial, high-precision robot that was capable of applying loads to the joint and measuring the joint displacement in 6 DOF. The system was equipped with novel, custom-made control hardware. In contrast to the commonly used sampling rates that are below 100 Hz, a rate of 4 kHz was realised for each DOF. This made it possible to implement advanced, highly dynamic, quasi-continuous closed-loop controllers. Thus oscillations of the robot were avoided, and measurements were speeded up. The stiffness of the entire system was greater than 44 kNm(-1) and 22 Nm deg(-1), and the maximum difference between two successive measurements was less than 0.5 deg. A sophisticated CT-based referencing routine facilitated the matching of kinematic data with the individual anatomy of the tested joint. The detailed detection of the elastic varus-valgus properties of a human knee joint is described, and the need for high spatial resolution is demonstrated.

  12. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    Evangelos I. Avgoulas

    2016-07-01

    Full Text Available There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  13. Image transmission system using adaptive joint source and channel decoding

    Liu, Weiliang; Daut, David G.

    2005-03-01

    In this paper, an adaptive joint source and channel decoding method is designed to accelerate the convergence of the iterative log-dimain sum-product decoding procedure of LDPC codes as well as to improve the reconstructed image quality. Error resilience modes are used in the JPEG2000 source codec, which makes it possible to provide useful source decoded information to the channel decoder. After each iteration, a tentative decoding is made and the channel decoded bits are then sent to the JPEG2000 decoder. Due to the error resilience modes, some bits are known to be either correct or in error. The positions of these bits are then fed back to the channel decoder. The log-likelihood ratios (LLR) of these bits are then modified by a weighting factor for the next iteration. By observing the statistics of the decoding procedure, the weighting factor is designed as a function of the channel condition. That is, for lower channel SNR, a larger factor is assigned, and vice versa. Results show that the proposed joint decoding methods can greatly reduce the number of iterations, and thereby reduce the decoding delay considerably. At the same time, this method always outperforms the non-source controlled decoding method up to 5dB in terms of PSNR for various reconstructed images.

  14. Joint image restoration and location in visual navigation system

    Wu, Yuefeng; Sang, Nong; Lin, Wei; Shao, Yuanjie

    2018-02-01

    Image location methods are the key technologies of visual navigation, most previous image location methods simply assume the ideal inputs without taking into account the real-world degradations (e.g. low resolution and blur). In view of such degradations, the conventional image location methods first perform image restoration and then match the restored image on the reference image. However, the defective output of the image restoration can affect the result of localization, by dealing with the restoration and location separately. In this paper, we present a joint image restoration and location (JRL) method, which utilizes the sparse representation prior to handle the challenging problem of low-quality image location. The sparse representation prior states that the degraded input image, if correctly restored, will have a good sparse representation in terms of the dictionary constructed from the reference image. By iteratively solving the image restoration in pursuit of the sparest representation, our method can achieve simultaneous restoration and location. Based on such a sparse representation prior, we demonstrate that the image restoration task and the location task can benefit greatly from each other. Extensive experiments on real scene images with Gaussian blur are carried out and our joint model outperforms the conventional methods of treating the two tasks independently.

  15. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  16. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  17. Smartphone supported upper limb prosthesis

    Hepp D.

    2015-09-01

    Full Text Available State of the art upper limb prostheses offer up to six active DoFs (degrees of freedom and are controlled using different grip patterns. This low number of DoFs combined with a machine-human-interface which does not provide control over all DoFs separately result in a lack of usability for the patient. The aim of this novel upper limb prosthesis is both offering simplified control possibilities for changing grip patterns depending on the patients’ priorities and the improvement of grasp capability. Design development followed the design process requirements given by the European Medical Device Directive 93/42 ECC and was structured into the topics mechanics, software and drive technology. First user needs were identified by literature research and by patient feedback. Consequently, concepts were evaluated against technical and usability requirements. A first evaluation prototype with one active DoF per finger was manufactured. In a second step a test setup with two active DoF per finger was designed. The prototype is connected to an Android based smartphone application. Two main grip patterns can be preselected in the software application and afterwards changed and used by the EMG signal. Three different control algorithms can be selected: “all-day”, “fine” and “tired muscle”. Further parameters can be adjusted to customize the prosthesis to the patients’ needs. First patient feedback certified the prosthesis an improved level of handling compared to the existing devices. Using the two DoF test setup, the possibilities of finger control with a neural network are evaluated at the moment. In a first user feedback test, the smartphone based software application increased the device usability, e.g. the change within preselected grip patterns and the “tired muscle” algorithm. Although the overall software application was positively rated, the handling of the prosthesis itself needs to be proven within a patient study to be

  18. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques

    Lu MX

    2018-02-01

    Full Text Available Minxun Lu,* Li Min,* Cong Xiao, Yongjiang Li, Yi Luo, Yong Zhou, Wenli Zhang, Chongqi Tu Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan, People’s Republic of China *These authors contributed equally to this work Introduction: Currently, it is challenging to treat giant cell tumor (GCT of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Methods: Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH questionnaire and Mayo wrist scoring systems. Results: The average follow-up was 14.45 months (range, 8–18 months. There was a significant decrease in the mean postoperative visual analog scale score (2.33 compared with the preoperative score (5.22; p<0.001. The mean DASH score and Mayo wrist score of the wrist joint function were 18.7 and 72, respectively. There was no local recurrence or lung metastasis. No complication associated with prosthesis was observed, including aseptic loosening, subluxation, and breakage. Joint space narrowing, or disuse osteoporosis, was also not found in all cases. Conclusion: En bloc resection and reconstruction with a personalized uncemented 3D-printed prosthesis can be alternative options to

  19. Joint Power Allocation for Multicast Systems with Physical-Layer Network Coding

    Zhu Wei-Ping

    2010-01-01

    Full Text Available This paper addresses the joint power allocation issue in physical-layer network coding (PLNC of multicast systems with two sources and two destinations communicating via a large number of distributed relays. By maximizing the achievable system rate, a constrained optimization problem is first formulated to jointly allocate powers for the source and relay terminals. Due to the nonconvex nature of the cost function, an iterative algorithm with guaranteed convergence is developed to solve the joint power allocation problem. As an alternative, an upper bound of the achievable rate is also derived to modify the original cost function in order to obtain a convex optimization solution. This approximation is shown to be asymptotically optimal in the sense of maximizing the achievable rate. It is confirmed through Monte Carlo simulations that the proposed joint power allocation schemes are superior to the existing schemes in terms of achievable rate and cumulative distribution function (CDF.

  20. Application of Joint Parameter Identification and State Estimation to a Fault-Tolerant Robot System

    Sun, Zhen; Yang, Zhenyu

    2011-01-01

    The joint parameter identification and state estimation technique is applied to develop a fault-tolerant space robot system. The potential faults in the considered system are abrupt parametric faults, which indicate that some system parameters will immediately deviate from their nominal values...

  1. Optimization Algorithms for Calculation of the Joint Design Point in Parallel Systems

    Enevoldsen, I.; Sørensen, John Dalsgaard

    1992-01-01

    In large structures it is often necessary to estimate the reliability of the system by use of parallel systems. Optimality criteria-based algorithms for calculation of the joint design point in a parallel system are described and efficient active set strategies are developed. Three possible...

  2. Adding a Mission to the Joint Polar Satellite System (JPSS) Common Ground System (CGS)

    Miller, S. W.; Grant, K. D.; Jamilkowski, M. L.

    2014-12-01

    The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). The Joint Polar Satellite System will replace the afternoon orbit component and ground processing system of the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA. The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological and geophysical observations of the Earth. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS). Developed and maintained by Raytheon Intelligence, Information and Services (IIS), the CGS is a multi-mission enterprise system serving NOAA, NASA and their national and international partners. The CGS provides a wide range of support to a number of missions: 1) Command and control and mission management for the Suomi National Polar-orbiting Partnership (S-NPP) mission today, expanding this support to the JPSS-1 satellite and the Polar Free Flyer mission in 2017 2) Data acquisition via a Polar Receptor Network (PRN) for S-NPP, the Japan Aerospace Exploration Agency's (JAXA) Global Change Observation Mission - Water (GCOM-W1), POES, and the Defense Meteorological Satellite Program (DMSP) and Coriolis/WindSat for the Department of Defense (DoD) 3) Data routing over a global fiber Wide Area Network (WAN) for S-NPP, JPSS-1, Polar Free Flyer, GCOM-W1, POES, DMSP, Coriolis/WindSat, the NASA Space Communications and Navigation (SCaN, which includes several Earth Observing System [EOS] missions), MetOp for the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT), and the National Science Foundation (NSF) 4) Environmental data processing and distribution for S-NPP, GCOM-W1 and JPSS-1 With this established infrastructure and existing suite of missions, the CGS

  3. COMPARISON OF CULTURE OF SYNOVIAL FLUID, PERIPROSTHETIC TISSUE AND PROSTHESIS SONICATE FOR THE DIAGNOSIS OF KNEE PROSTHESIS INFECTION

    Andrej Trampuž

    2003-03-01

    Full Text Available Background. Synovial fluid and periprosthetic tissue specimens are the standard specimens cultured for the diagnosis of prosthetic joint infection (PJI. We hypothesize that ultrasonication of the explanted prosthesis may improve diagnosis of PJI by dislodging biofilm bacteria from the prosthesis surface and improve the sensitivity and specificity of diagnosis of PJI.Methods. Included were patients undergoing knee prosthesis exchange for septic or biomechanical failure and have not received antimicrobial therapy in the last 2 weeks prior specimen collection. Cultures of synovial fluid and periprosthetic tissue specimens were performed per the usual clinical practice. Additionally, explanted joint components were sonicated for 5 minutes at frequency 40 kHz in sterile Ringer’s solution; aliquots of 0.5 ml sonicate were plated onto five aerobic and five anaerobic blood agar plates, and incubated at 37 °C and examined for the next seven days. The number and identity of each colony morphology was recorded.Results. 35 patients undergoing knee replacement have been studied (24 for aseptic biomechanical failure and 11 for suspected PJI. In patients with PJI, coagulase-negative staphylococci (7 cases, Corynebacterium spp. (2 cases, Staphylococcus aureus (1 case, and viridans group streptococcus (1 case were recovered. Culture sensitivity and specificity were for synovial fluid 88% and 100%, for periprosthetic tissue 83% and 81%, and for explant sonicate 91% and 100%, respectively. In sonicate cultures higher numbers of microorganisms than in periprosthetic tissue cultures were consistently detected.Conclusions. Using synovial fluid, periprosthetic tissue, and explant sonicate cultures, 12%, 17% and 9% of PJI were missed, respectively. Explant sonicate cultures were the most sensitive with respect to the diagnosis of PJI, indicating that explant ultrasonication may improve bacterial recovery. In sonicate cultures, infecting organisms were detected in

  4. Selection of optimal multispectral imaging system parameters for small joint arthritis detection

    Dolenec, Rok; Laistler, Elmar; Stergar, Jost; Milanic, Matija

    2018-02-01

    Early detection and treatment of arthritis is essential for a successful outcome of the treatment, but it has proven to be very challenging with existing diagnostic methods. Novel methods based on the optical imaging of the affected joints are becoming an attractive alternative. A non-contact multispectral imaging (MSI) system for imaging of small joints of human hands and feet is being developed. In this work, a numerical simulation of the MSI system is presented. The purpose of the simulation is to determine the optimal design parameters. Inflamed and unaffected human joint models were constructed with a realistic geometry and tissue distributions, based on a MRI scan of a human finger with a spatial resolution of 0.2 mm. The light transport simulation is based on a weighted-photon 3D Monte Carlo method utilizing CUDA GPU acceleration. An uniform illumination of the finger within the 400-1100 nm spectral range was simulated and the photons exiting the joint were recorded using different acceptance angles. From the obtained reflectance and transmittance images the spectral and spatial features most indicative of inflammation were identified. Optimal acceptance angle and spectral bands were determined. This study demonstrates that proper selection of MSI system parameters critically affects ability of a MSI system to discriminate the unaffected and inflamed joints. The presented system design optimization approach could be applied to other pathologies.

  5. Inverse Modeling of Human Knee Joint Based on Geometry and Vision Systems for Exoskeleton Applications

    Eduardo Piña-Martínez

    2015-01-01

    Full Text Available Current trends in Robotics aim to close the gap that separates technology and humans, bringing novel robotic devices in order to improve human performance. Although robotic exoskeletons represent a breakthrough in mobility enhancement, there are design challenges related to the forces exerted to the users’ joints that result in severe injuries. This occurs due to the fact that most of the current developments consider the joints as noninvariant rotational axes. This paper proposes the use of commercial vision systems in order to perform biomimetic joint design for robotic exoskeletons. This work proposes a kinematic model based on irregular shaped cams as the joint mechanism that emulates the bone-to-bone joints in the human body. The paper follows a geometric approach for determining the location of the instantaneous center of rotation in order to design the cam contours. Furthermore, the use of a commercial vision system is proposed as the main measurement tool due to its noninvasive feature and for allowing subjects under measurement to move freely. The application of this method resulted in relevant information about the displacements of the instantaneous center of rotation at the human knee joint.

  6. Welding technology transfer task/laser based weld joint tracking system for compressor girth welds

    Looney, Alan

    1991-01-01

    Sensors to control and monitor welding operations are currently being developed at Marshall Space Flight Center. The laser based weld bead profiler/torch rotation sensor was modified to provide a weld joint tracking system for compressor girth welds. The tracking system features a precision laser based vision sensor, automated two-axis machine motion, and an industrial PC controller. The system benefits are elimination of weld repairs caused by joint tracking errors which reduces manufacturing costs and increases production output, simplification of tooling, and free costly manufacturing floor space.

  7. The development of auto-sealing system for field joints of polyethylene coated pipelines

    Okano, Yoshihiro [NKK Corp., Tsu, Mie (Japan); Shoji, Norio [NKK Corp., Yokohama (Japan); Namioka, Toshiyuki [Nippon Kokan Koji Corp., Osaka (Japan); Komura, Minoru [Nitto Denko Corp., Fukaya, Saitama (Japan)

    1997-08-01

    The paper describes the development of a system to create high quality, automatic sealing of field joints of polyethylene coated pipelines. The system uses a combination of electrically heated shrink sleeves and a low pressure chamber. The self-heating shrink sleeves include electric wires and heat themselves when connected to electricity. A method was developed to eliminate air trapped between the sleeve and steel pipe by shrinking the sleeves under low pressure. The low pressure condition was automatically and easily attained by using a vacuum chamber. The authors verified that the system produces high quality sealing of field joints.

  8. Analysis of postmarket complaints database for the iFuse SI Joint Fusion System®: a minimally invasive treatment for degenerative sacroiliitis and sacroiliac joint disruption.

    Miller, Larry E; Reckling, W Carlton; Block, Jon E

    2013-01-01

    The sacroiliac joint is a common but under-recognized source of low back and gluteal pain. Patients with degenerative sacroiliitis or sacroiliac joint disruption resistant to nonsurgical treatments may undergo open surgery with sacroiliac joint arthrodesis, although outcomes are mixed and risks are significant. Minimally invasive sacroiliac joint arthrodesis was developed to minimize the risk of iatrogenic injury and to improve patient outcomes compared with open surgery. Between April 2009 and January 2013, 5319 patients were treated with the iFuse SI Joint Fusion System® for conditions including sacroiliac joint disruption and degenerative sacroiliitis. A database was prospectively developed to record all complaints reported to the manufacturer in patients treated with the iFuse device. Complaints were collected through spontaneous reporting mechanisms in support of ongoing mandatory postmarket surveillance efforts. Complaints were reported in 204 (3.8%) patients treated with the iFuse system. Pain was the most commonly reported clinical complaint (n = 119, 2.2%), with nerve impingement (n = 48, 0.9%) and recurrent sacroiliac joint pain (n = 43, 0.8%) most frequently cited. All other clinical complaints were rare (≤0.2%). Ninety-six revision surgeries were performed in 94 (1.8%) patients at a median follow-up of four (range 0-30) months. Revisions were typically performed in the early postoperative period for treatment of a symptomatic malpositioned implant (n = 46, 0.9%) or to correct an improperly sized implant in an asymptomatic patient (n = 10, 0.2%). Revisions in the late postoperative period were performed to treat symptom recurrence (n = 34, 0.6%) or for continued pain of undetermined etiology (n = 6, 0.1%). Analysis of a postmarket product complaints database demonstrates an overall low risk of complaints with the iFuse SI Joint Fusion System in patients with degenerative sacroiliitis or sacroiliac joint disruption.

  9. Effect of joint mechanism on vehicle redirectional capability of water-filled road safety barrier systems.

    Thiyahuddin, M I; Thambiratnam, D P; Gu, Y T

    2014-10-01

    Portable water-filled barriers (PWFBs) are roadside appurtenances that prevent vehicles from penetrating into temporary construction zones on roadways. PWFBs are required to satisfy the strict regulations for vehicle re-direction in tests. However, many of the current PWFBs fail to re-direct the vehicle at high speeds due to the inability of the joints to provide appropriate stiffness. The joint mechanism hence plays a crucial role in the performance of a PWFB system at high speed impacts. This paper investigates the desired features of the joint mechanism in a PWFB system that can re-direct vehicles at high speeds, while limiting the lateral displacement to acceptable limits. A rectangular "wall" representative of a 30m long barrier system was modeled and a novel method of joining adjacent road barriers was introduced through appropriate pin-joint connections. The impact response of the barrier "wall" and the vehicle was obtained and the results show that a rotational stiffness of 3000kNm/rad at the joints seems to provide the desired features of the PWFB system to re-direct impacting vehicles and restrict the lateral deflection. These research findings will be useful to safety engineers and road barrier designers in developing a new generation of PWFBs for increased road safety. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Candida albicans, Staphylococcus aureus and Streptococcus mutans colonization in patients wearing dental prosthesis.

    Baena-Monroy, Tania; Moreno-Maldonado, Víctor; Franco-Martínez, Fernando; Aldape-Barrios, Beatriz; Quindós, Guillermo; Sánchez-Vargas, Luis Octavio

    2005-04-01

    Denture stomatitis is associated to Candida albicans, different bacteria and other co-factors such as an acid pH, a carbohydrate ingestion increase, different systemic illnesses and pharmacological treatments. The aim of this study was to determine Candida albicans, Staphylococcus aureus and Streptococcus mutans prevalence in the mucous membrane and prosthesis of patients with and without atrophic denture stomatitis and its relationship with other potential clinical co-factors. Saliva was collected from 105 patients (62 female and 43 male) wearing dental prosthesis in order to measure their pH. Oral samples of the mucous membrane and the internal surface of dental prosthesis were taken with sterile cotton to proceed with the microbiological study. The identification of the isolated microorganisms was performed using conventional microbiological methods. Diabetes and Hypertension were the most frequent systemic illnesses. High carbohydrate ingestion was observed in numerous patients. Atrophic denture stomatitis was reported in 50 patients and the pH average in saliva was of 5.2. The presence of C albicans, S. aureus and S. mutans in the mucous membrane and prosthesis was of 51.4%, 52.4% and 67.6%, respectively. C. albicans was isolated in 66.7% from the prosthesis, whereas S. aureus and S. mutans were isolated in 49.5% of those same prosthesis. C. albicans was isolated in 86% of the patients with atrophic denture stomatitis and S. aureus was isolated in a similar percentage (84% of patients). The isolation of S. mutans was less frequent, and it was observed in 16% of the oral samples of these patients. C. albicans, S. aureus and S. mutans frequently colonize the oral mucous of patients wearing dental prosthesis. This illness-bearing condition is more frequent in patients with denture stomatitis, even though dental prosthesis colonization is lower than in the oral mucous.

  11. Improved decryption quality and security of a joint transform correlator-based encryption system

    Vilardy, Juan M; Millán, María S; Pérez-Cabré, Elisabet

    2013-01-01

    Some image encryption systems based on modified double random phase encoding and joint transform correlator architecture produce low quality decrypted images and are vulnerable to a variety of attacks. In this work, we analyse the algorithm of some reported methods that optically implement the double random phase encryption in a joint transform correlator. We show that it is possible to significantly improve the quality of the decrypted image by introducing a simple nonlinear operation in the encrypted function that contains the joint power spectrum. This nonlinearity also makes the system more resistant to chosen-plaintext attacks. We additionally explore the system resistance against this type of attack when a variety of probability density functions are used to generate the two random phase masks of the encryption–decryption process. Numerical results are presented and discussed. (paper)

  12. Improved decryption quality and security of a joint transform correlator-based encryption system

    Vilardy, Juan M.; Millán, María S.; Pérez-Cabré, Elisabet

    2013-02-01

    Some image encryption systems based on modified double random phase encoding and joint transform correlator architecture produce low quality decrypted images and are vulnerable to a variety of attacks. In this work, we analyse the algorithm of some reported methods that optically implement the double random phase encryption in a joint transform correlator. We show that it is possible to significantly improve the quality of the decrypted image by introducing a simple nonlinear operation in the encrypted function that contains the joint power spectrum. This nonlinearity also makes the system more resistant to chosen-plaintext attacks. We additionally explore the system resistance against this type of attack when a variety of probability density functions are used to generate the two random phase masks of the encryption-decryption process. Numerical results are presented and discussed.

  13. Patients with hip prosthesis: radiotherapy treatment planning considerations

    Ganesh, K.M.; Supe, Sanjay S.

    2000-01-01

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  14. Stretch due to Penile Prosthesis Reservoir Migration

    E. Baten

    2016-03-01

    Full Text Available A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely rare but can cause several complications, such as stretch.

  15. Cost analysis of debridement and retention for management of prosthetic joint infection.

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  16. Local Gene Delivery System by Bubble Liposomes and Ultrasound Exposure into Joint Synovium

    Yoichi Negishi

    2011-01-01

    Full Text Available Recently, we have developed novel polyethylene glycol modified liposomes (bubble liposomes; BL entrapping an ultrasound (US imaging gas, which can work as a gene delivery tool with US exposure. In this study, we investigated the usefulness of US-mediated gene transfer systems with BL into synoviocytes in vitro and joint synovium in vivo. Highly efficient gene transfer could be achieved in the cultured primary synoviocytes transfected with the combination of BL and US exposure, compared to treatment with plasmid DNA (pDNA alone, pDNA plus BL, or pDNA plus US. When BL was injected into the knee joints of mice, and US exposure was applied transcutaneously to the injection site, highly efficient gene expression could be observed in the knee joint transfected with the combination of BL and US exposure, compared to treatment with pDNA alone, pDNA plus BL, or pDNA plus US. The localized and prolonged gene expression was also shown by an in vivo luciferase imaging system. Thus, this local gene delivery system into joint synovium using the combination of BL and US exposure may be an effective means for gene therapy in joint disorders.

  17. Coordinated joint motion control system with position error correction

    Danko, George L.

    2016-04-05

    Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

  18. Low-complexity Joint Sub-carrier Phase Noise Compensation for Digital Multi-carrier Systems

    Yankov, Metodi Plamenov; Barletta, Luca; Zibar, Darko

    2017-01-01

    Joint sub-carrier phase noise processing is proposed which recovers the SNR penalty related to decreased sub-carrier baudrate w.r.t. single carrier systems. The method enables digital sub-banding to be safely employed for nonlinear mitigation for modulation formats of up to 256-QAM.......Joint sub-carrier phase noise processing is proposed which recovers the SNR penalty related to decreased sub-carrier baudrate w.r.t. single carrier systems. The method enables digital sub-banding to be safely employed for nonlinear mitigation for modulation formats of up to 256-QAM....

  19. Joint Polar Satellite System (JPSS) Common Ground System (CGS) Overview and Architectural Tenets

    Miller, S. W.; Grant, K. D.; Jamilkowski, M. L.

    2013-12-01

    The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). The Joint Polar Satellite System will replace the afternoon orbit component and ground processing system of the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA. The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological and geophysical observations of the Earth. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS). Developed and maintained by Raytheon Intelligence and Information Systems (IIS), the CGS is a multi-mission enterprise system serving NOAA, NASA and their national and international partners. The CGS provides a wide range of support to a number of missions: 1) Command and control and mission management for the Suomi National Polar Partnership (S-NPP) mission today, expanding this support to the JPSS-1 satellite and the Polar Free Flyer mission in 2017 2) Data acquisition via a Polar Receptor Network (PRN) for S-NPP, the Japan Aerospace Exploration Agency's (JAXA) Global Change Observation Mission - Water (GCOM-W1), POES, and the Defense Meteorological Satellite Program (DMSP) and Coriolis/WindSat for the Department of Defense (DoD) 3) Data routing over a global fiber Wide Area Network (WAN) for S-NPP, JPSS-1, Polar Free Flyer, GCOM-W1, POES, DMSP, Coriolis/WindSat, the NASA Space Communications and Navigation (SCaN, which includes several Earth Observing System [EOS] missions), MetOp for the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT), and the National Science Foundation (NSF) 4) Environmental data processing and distribution for S-NPP, GCOM-W1 and JPSS-1 The CGS architecture will receive a technology refresh in 2015 to satisfy several key

  20. Stochastic coordination of joint wind and photovoltaic systems with energy storage in day-ahead market

    Gomes, I.L.R.; Pousinho, H.M.I.; Melício, R.; Mendes, V.M.F.

    2017-01-01

    This paper presents an optimal bid submission in a day-ahead electricity market for the problem of joint operation of wind with photovoltaic power systems having an energy storage device. Uncertainty not only due to the electricity market price, but also due to wind and photovoltaic powers is one of the main characteristics of this submission. The problem is formulated as a two-stage stochastic programming problem. The optimal bids and the energy flow in the batteries are the first-stage variables and the energy deviation is the second stage variable of the problem. Energy storage is a way to harness renewable energy conversion, allowing the store and discharge of energy at conveniently market prices. A case study with data from the Iberian day-ahead electricity market is presented and a comparison between joint and disjoint operations is discussed. - • Joint wind and PV systems with energy storage. • Electricity markets. • Stochastic optimization. • Day-ahead market.

  1. 21 CFR 878.3720 - Tracheal prosthesis.

    2010-04-01

    ...) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a silicone... of the trachea or trachealbronchial tree. It may be unbranched or contain one or two branches. The...

  2. Finger prosthesis: a boon to handicapped.

    Gupta, Ridhima; Kumar, Lakshya; Rao, Jitendra; Singh, Kamleshwar

    2013-08-29

    This is a clinical case report of a 52-year-old male patient with four partially missing fingers of the left hand. The article describes the clinical and laboratory procedure of making prosthesis with modern silicone material. A wax pattern was fabricated using the right hand of the patient. A special type of wax was formulated to make the pattern so that it can be easily moulded and carved. Intrinsic and extrinsic staining was also performed to match the adjacent skin colour. The patient was given the finger prosthesis and was asked to use a half glove (sports) to mask the junction between the prosthesis and the normal tissue. It also provides additional retention to the artificial fingers. The patient felt his social acceptance improved after wearing the finger prosthesis.

  3. Joint Opaque booking systems for online travel agencies

    Ogonowska , Malgorzata; Torre , Dominique

    2010-01-01

    This paper analyzes the properties of the advanced Opaque booking systems used by the online travel agencies in conjunction with their traditional transparent booking system. In section 2 we present an updated literature review. This review underlines the interest and the specicities of Opaque goods in the Tourism Industry. It also characterizes properties of the Name-Your-Own-Price (NYOP) channel introduced by Priceline and oering probabilistic goods to potential travelers. In the section 3 ...

  4. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  5. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Resilience assessment of interdependent infrastructure systems: With a focus on joint restoration modeling and analysis

    Ouyang, Min; Wang, Zhenghua

    2015-01-01

    As infrastructure systems are highly interconnected, it is crucial to analyze their resilience with the consideration of their interdependencies. This paper adapts an existing resilience assessment framework for single systems to interdependent systems and mainly focuses on modeling and resilience contribution analysis of multi-systems’ joint restoration processes, which are seldom addressed in the literature. Taking interdependent power and gas systems in Houston, Texas, USA under hurricane hazards as an illustrative exmaple, five types of joint restoration stategies are proposed, including random restoration strategy RS 1 , independent restoration strategy RS 2 , power first and gas second restoration strategy RS 3 , gas aimed restoration strategy RS 4 , and power and gas compromised restoration strategy RS 5 . Results show that under limited restoration resources, RS 1 produces the least resilience for both systems, RS 2 and RS 3 both generates the largest power system resilience while RS 4 is the best for the gas system; and if quantifying the total resilience as the evenly weighted sum of two systems’ individual resilience, RS 5 produces the largest total resilience. The proposed method can help decision makers search optimum joint restoration strategy, which can significantly enhance both systems’ resilience. - Highlights: • We propose a method to assess resilience of interdependent infrastructure systems. • We consider unidirectional interdependencies from power system to gas system. • Multi-systems’ restoration processes are solved by using genetic algorithm. • Effectiveness of five restoration strategies are compared and analyzed. • Interdependency-based strategies produce the largest total resilience

  7. Topical versus systemic diclofenac in the treatment of temporo-mandibular joint dysfunction symptoms.

    Di Rienzo Businco, L; Di Rienzo Businco, A; D'Emilia, M; Lauriello, M; Coen Tirelli, G

    2004-10-01

    spontaneously. Our results demonstrate that topically applied diclofenac and oral diclofenac are equally effective in the treatment of temporomandibular joint dysfunction symptoms. Topical diclofenac has the advantage that it does not have adverse systemic effects, whereas oral diclofenac had untoward effects on the gastric apparatus. The efficacy of diclofenac topically applied on the temporomandibular joint region observed in group B is explained by the association of diclofenac with dimethyl-sulfoxide, which enables a rapid effective penetration into the joint tissues. It is noteworthy that dimethyl-sulfoxide favours transuctaneous absorption when used in a multi-dose regime as in our study with 4 doses a day. Thus, single, "as required", applications should be avoided because this practice results in scarce absorption of diclofenac.

  8. Joint Polar Satellite System (JPSS) System Architecture: Suomi-NPP to the Future

    Furgerson, J.; Layns, A.; Feeley, J. H.; Griffin, A.; Trumbower, G.

    2014-12-01

    The National Oceanic and Atmospheric Administration (NOAA) is acquiring the next-generation weather and environmental satellite system, named the Joint Polar Satellite System (JPSS). NOAA has overall responsibility for the system including funding and requirements while the National Aeronautics and Space Administration (NASA) serves as the acquisition and development agent. The Suomi National Polar-orbiting Partnership (S-NPP) satellite was launched on 28 October, 2011, and is a pathfinder for JPSS and provides continuity for the NASA Earth Observation System and the NOAA Polar-orbiting Operational Environmental Satellite (POES) system. S-NPP and the follow-on JPSS satellites will operate in the 1330 LTAN orbit. JPSS-1 is scheduled to launch in early 2017. NASA is developing the Common Ground System which will process JPSS data and has the flexibility to process data from other satellites. This poster will provide a top level status update of the program, as well as an overview of the JPSS system architecture. The space segment carries a suite of sensors that collect meteorological, oceanographic, and climatological observations of the earth and atmosphere. The system design allows centralized mission management and delivers high quality environmental products to military, civil and scientific users through a Command, Control, and Communication Segment (C3S). The data processing for S-NPP/JPSS is accomplished through an Interface Data Processing Segment (IDPS)/Field Terminal Segment (FTS) that processes S-NPP/JPSS satellite data to provide environmental data products to U.S. and international partners as well as remote terminal users throughout the world.

  9. A remote joint system for large vacuum ducts

    Hagmann, D.B.; Coughlan, J.B.

    1983-01-01

    A large remote vacuum duct joining system has been developed for fusion machines that uses several two-jaw screwdriven clamps. The preferred location for clamp installation is inside the vacuum duct where access space is available for the actuating device. It also decreases space needed for handling operations exterior to the duct. The clamp system is unique in that it is low cost, applies force directly over the seal, permits leak testing to the seal annulus, is highly reliable, can be remotely replaced, and is usable on a variety of other applications

  10. Joint Optimal Design and Operation of Hybrid Energy Storage Systems

    Y. Ghiassi-Farrokhfal (Yashar); C. Rosenberg; S. Keshav (Srinivasam); M.-B. Adjaho (Marie-Benedicte)

    2016-01-01

    markdownabstractThe wide range of performance characteristics of storage technologies motivates the use of a hybrid energy storage systems (HESS) that combines the best features of multiple technologies. However, HESS design is complex, in that it involves the choice of storage technologies, the

  11. Scalable multifunction RF system concepts for joint operations

    Otten, M.P.G.; Wit, J.J.M. de; Smits, F.M.A.; Rossum, W.L. van; Huizing, A.

    2010-01-01

    RF systems based on modular architectures have the potential of better re-use of technology, decreasing development time, and decreasing life cycle cost. Moreover, modular architectures provide scalability, allowing low cost upgrades and adaptability to different platforms. To achieve maximum

  12. A prosthesis-specific multi-link segment model of lower-limb amputee sprinting.

    Rigney, Stacey M; Simmons, Anne; Kark, Lauren

    2016-10-03

    Lower-limb amputees commonly utilize non-articulating energy storage and return (ESAR) prostheses for high impact activities such as sprinting. Despite these prostheses lacking an articulating ankle joint, amputee gait analysis conventionally features a two-link segment model of the prosthetic foot. This paper investigated the effects of the selected link segment model׳s marker-set and geometry on a unilateral amputee sprinter׳s calculated lower-limb kinematics, kinetics and energetics. A total of five lower-limb models of the Ottobock ® 1E90 Sprinter were developed, including two conventional shank-foot models that each used a different version of the Plug-in-Gait (PiG) marker-set to test the effect of prosthesis ankle marker location. Two Hybrid prosthesis-specific models were then developed, also using the PiG marker-sets, with the anatomical shank and foot replaced by prosthesis-specific geometry separated into two segments. Finally, a Multi-link segment (MLS) model was developed, consisting of six segments for the prosthesis as defined by a custom marker-set. All full-body musculoskeletal models were tested using four trials of experimental marker trajectories within OpenSim 3.2 (Stanford, California, USA) to find the affected and unaffected hip, knee and ankle kinematics, kinetics and energetics. The geometry of the selected lower-limb prosthesis model was found to significantly affect all variables on the affected leg (p prosthesis-specific spatial, inertial and elastic properties from full-body models significantly affects the calculated amputee gait characteristics, and we therefore recommend the implementation of a MLS model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The Talar Body Prosthesis: Results at Ten to Thirty-six Years of Follow-up.

    Harnroongroj, Thos; Harnroongroj, Thossart

    2014-07-16

    Satisfactory results of implantation of the talar body prosthesis were reported in 1997, although some complications associated with the initial design were noted. The present study evaluated outcomes of treatment with a modified talar body prosthesis. Of the thirty-six talar body prostheses implanted with use of a transmalleolar surgical approach from 1974 to 2011, thirty-three were available for follow-up at ten to thirty-six years or had failed prior to that time. The indication for implantation had been osteonecrosis in twenty-three patients, a comminuted talar fracture in eight, and a talar body tumor in two. Twenty-eight of the thirty-three prostheses were still in place at the time of final follow-up and five had failed prior to five years. The duration of follow-up was ten to twenty years in eight patients, twenty to thirty years in eleven, and thirty to thirty-six years in nine. The AOFAS (American Orthopaedic Foot & Ankle Society) ankle-hindfoot score did not differ significantly among these three groups. Patients over sixty-five years of age with underlying disease that impeded walking ability had lower AOFAS scores. Early prosthesis failure occurred as a result of size mismatch in two patients, tumor recurrence in one, infection in one, and osteonecrosis of the talar head and neck in one. These failures, which occurred at eight to fifty-seven months, were treated with tibiotalar arthrodesis in three patients, prosthesis revision in one, and below-the-knee amputation in one. Although early prosthesis failure may occur, survival of the talar body prosthesis can provide satisfactory ankle and foot function. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  14. Joint illumination and visible-light communication systems : data rates and extra power consumption

    Tsiatmas, Anagnostis; Willems, Frans; Linnartz, Jean-Paul; Baggen, C.P.M.J.; Bergmans, Jan

    2015-01-01

    Visible Light Communications (VLC) have been promoted as an energy-efficient Gb/s-technology for indoor settings, since VLC can be merged with the illumination functionality. As a result, Joint Illumination and visible-light Communication (JIC) systems are perceived as a green technology and the

  15. Experience of the implementation of quality management system at the joint stock company 'Mashinostroitelny zavod', Electrostal

    Mezhuev, V.; Tsiboulia, V.; Kiruyshkin, A.; Tchirkov, V.

    2000-01-01

    The paper describes major steps of development and implementation of Quality Management System (QMS) in nuclear fuel fabrication at Joint Stock Company 'Mashinostroitelny zavod', Electrostal, Russian Federation. Special emphasis is paid to the estimation of QMS effectiveness, current impact of QMS implementation on nuclear fuel quality, sales market and directions for further QMS development. (author)

  16. Joint action modulates motor system involvement during action observation in 3-year-olds

    Meyer, M.; Hunnius, S.; Elk, M. van; Ede, F.L. van; Bekkering, H.

    2011-01-01

    When we are engaged in a joint action, we need to integrate our partner's actions with our own actions. Previous research has shown that in adults the involvement of one's own motor system is enhanced during observation of an action partner as compared to during observation of an individual actor.

  17. Assessment of the Accounting and Joint Accounting/Computer Information Systems Programs.

    Appiah, John; Cernigliaro, James; Davis, Jeffrey; Gordon, Millicent; Richards, Yves; Santamaria, Fernando; Siegel, Annette; Lytle, Namy; Wharton, Patrick

    This document presents City University of New York LaGuardia Community College's Department of Accounting and Managerial Studies assessment of its accounting and joint accounting/computer information systems programs report, and includes the following items: (1) description of the mission and goals of the Department of Accounting and Managerial…

  18. Possibility of designing television control system for welded joint formation on electron beam welding

    Lifshits, M.L.; Lobanova, N.G.

    1987-01-01

    Regression equations (models), connecting seam characteristics: width and depth with the welding bath leading front in joint gap and seam width respectively - are obtained at electron beam welding of circular articles with guaranteed clearance with application of television control system. Dispersion analysis showed the models adequancy to the process in the range, where they were identified

  19. Application of Transaction Cost Economics to Capabilities-Based Acquisition: Exploring Single Service vs. Joint Service Programs and Single Systems vs. System-of-Systems

    Angelis, Diana; Dillard, John; Franck, Raymond; Melese, Francois; Brown, Mary M; Flowe, Robert M

    2008-01-01

    The US Department of Defense (DoD) is in the process of radical transformation -- transformation to a national security strategy predicated on joint Service purchases and complex System-of-Systems (SoS) capabilities...

  20. Joint optimisation of the future Danish waste and energy system

    Münster, Marie; Pizarro, Amalia Rosa; Salvucci, Raffaele

    2015-01-01

    in future scenarios with higher biomass consumption, where the average heat prices are higher. In both scenarios, biogas produced from organic waste is upgraded and fed into the natural gas grid and waste is incinerated rather than being centrally sorted in a material recovery facility.......In this article the impact of the future development of the energy system on the feasibility of waste treatment options is analysed. In the article two different optimization tools are used: a regional electricity model (Balmorel) and a national waste treatment and district heating model (Opti......Waste). When performing optimization by minimizing the socio-economic costs, into future energy systems with high wind power production, it proves feasible primarily to incinerate waste in large scale combined heat and power (CHP) plants, whereas more incineration takes place in decentralized CHP plants...

  1. Osseointegrated silicone finger prosthesis using dental implants: a renovated technique.

    Vinnakota, Dileep Nag; Sankar, V Vijay; Chirumamilla, Naveen; Reddy, V Vamsikrishna

    2014-11-01

    In clinical practice, we come across patients with traumatically amputated or congenitally missing partial or complete fingers that can be restored using microsurgical replantation or transplantation procedures. However, in some cases this might not be possible due to systemic or local factors and the lost or missing part has to be replaced prosthetically to offer psychological and functional wellbeing. These prostheses can be constructed with various materials like acrylics or silicone retained with the help of auxiliary aids. However, these prostheses cause some hindrance in performing functions like writing, typing, etc. The aim of the present trial was to ameliorate the existing design of implant supported finger prosthesis. Distal phalange of middle finger replaced with implant supported silicone finger prosthesis is modified by utilizing a metal framework to support silicone material to improve rigidity while working. We could achieve a good function, esthetics and tactile sensibility with this modified design. Whenever, feasible this design can improve the performance and patients feel a deep sense of satisfaction and improved self-esteem with this modified prosthesis.

  2. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    Ali Torkaman

    2016-01-01

    Full Text Available Background: Surgical treatments for acromioclavicular (AC joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH, constant and visual analogue scale (VAS scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71% were male and four (14.28% were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements (P=0.001, P=0.0001, P=0.0001, respectively. There were not any significant differences between right and left coracoclavicular (P=0.238, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments.

  3. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin

    2016-01-01

    Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217

  4. Joint Space Operations Center (JSpOC) Mission System (JMS)

    Morton, M.; Roberts, T.

    2011-09-01

    US space capabilities benefit the economy, national security, international relationships, scientific discovery, and our quality of life. Realizing these space responsibilities is challenging not only because the space domain is increasingly congested, contested, and competitive but is further complicated by the legacy space situational awareness (SSA) systems approaching end of life and inability to provide the breadth of SSA and command and control (C2) of space forces in this challenging domain. JMS will provide the capabilities to effectively employ space forces in this challenging domain. Requirements for JMS were developed based on regular, on-going engagement with the warfighter. The use of DoD Architecture Framework (DoDAF) products facilitated requirements scoping and understanding and transferred directly to defining and documenting the requirements in the approved Capability Development Document (CDD). As part of the risk reduction efforts, the Electronic System Center (ESC) JMS System Program Office (SPO) fielded JMS Capability Package (CP) 0 which includes an initial service oriented architecture (SOA) and user defined operational picture (UDOP) along with force status, sensor management, and analysis tools. Development efforts are planned to leverage and integrate prototypes and other research projects from Defense Advanced Research Projects Agency, Air Force Research Laboratories, Space Innovation and Development Center, and Massachusetts Institute of Technology/Lincoln Laboratories. JMS provides a number of benefits to the space community: a reduction in operational “transaction time” to accomplish key activities and processes; ability to process the increased volume of metric observations from new sensors (e.g., SBSS, SST, Space Fence), as well as owner/operator ephemerides thus enhancing the high accuracy near-real-time catalog, and greater automation of SSA data sharing supporting collaboration with government, civil, commercial, and foreign

  5. Joint System of the National Hydrometeorology for disaster prevention

    Lim, J.; Cho, K.; Lee, Y. S.; Jung, H. S.; Yoo, H. D.; Ryu, D.; Kwon, J.

    2014-12-01

    Hydrological disaster relief expenditure accounts for as much as 70 percent of total expenditure of disasters occurring in Korea. Since the response to and recovery of disasters are normally based on previous experiences, there have been limitations when dealing with ever-increasing localized heavy rainfall with short range in the era of climate change. Therefore, it became necessary to establish a system that can respond to a disaster in advance through the analysis and prediction of hydrometeorological information. Because a wide range of big data is essential, it cannot be done by a single agency only. That is why the three hydrometeorology-related agencies cooperated to establish a pilot (trial) system at Soemjingang basin in 2013. The three governmental agencies include the National Emergency Management Agency (NEMA) in charge of disaster prevention and public safety, the National Geographic Information Institute (NGII under Ministry of Land, Infrastructure and Transport) in charge of geographical data, and the Korea Meteorological Administration (KMA) in charge of weather information. This pilot system was designed to be able to respond to disasters in advance through providing a damage prediction information for flash flood to public officers for safety part using high resolution precipitation prediction data provided by the KMA and high precision geographic data by NGII. To produce precipitation prediction data with high resolution, the KMA conducted downscaling from 25km×25km global model to 3km×3km local model and is running the local model twice a day. To maximize the utility of weather prediction information, the KMA is providing the prediction information for 7 days with 1 hour interval at Soemjingang basin to monitor and predict not only flood but also drought. As no prediction is complete without a description of its uncertainty, it is planned to continuously develop the skills to improve the uncertainty of the prediction on weather and its impact

  6. Vision systems for the inspection of resistance welding joints

    Hildebrand, Lars; Fathi, Madjid

    2000-06-01

    Many automated quality inspection systems make use of brightness and contrast features of the objects being inspected. This reduces the complexity of the problem solving methods, as well as the demand for computational capacity. Nevertheless a lot of significant information is located in color features of the objects. This paper describes a method, that allows the evaluation of color information in a very compact and efficient way. The described method uses a combination of multi-valued logic and a special color model. We use fuzzy logic as multi-valued logic, and the HSI color model, but any multi-valued logic, that allows rule-based reasoning can be used. The HSI color model can also be exchanged with other color models, if special demands require this.

  7. Mirror neuron system as the joint from action to language.

    Chen, Wei; Yuan, Ti-Fei

    2008-08-01

    Mirror neuron system (MNS) represents one of the most important discoveries of cognitive neuroscience in the past decade, and it has been found to involve in multiple aspects of brain functions including action understanding, imitation, language understanding, empathy, action prediction and speech evolution. This manuscript reviewed the function of MNS in action understanding as well as language evolution, and specifically assessed its roles as the bridge from body language to fluent speeches. Then we discussed the speech defects of autism patients due to the disruption of MNS. Finally, given that MNS is plastic in adult brain, we proposed MNS targeted therapy provides an efficient rehabilitation approach for brain damages conditions as well as autism patients.

  8. Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees

    Wilson Carlos da Silva Júnior

    Full Text Available Introduction Modern transfemoral knee prostheses are designed to offer comfort and self-confidence to amputees. These prostheses are mainly based upon either a passive concept, with a damping system, or an active computational intelligent design to control knee motion during the swing phase. In Brazil, most lower extremity amputees are unable to afford modern prostheses due to their high cost. In this work, we present the conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees. Methods The concept of the prosthesis is based on a control system with sensors for loads, which are installed on the amputee’s preserved leg and used as a mirror for the movement of the prosthesis. Mechanical strength analysis, using the Finite Element Method, electromechanical tests for the sensors and actuators and verification of data acquisition, signal conditioning and data transferring to the knee prosthesis were performed. Results The laboratory tests performed showed the feasibility of the proposed design. The electromechanical concept that was used enabled a controlled activation of the knee prosthesis by the two load cells located on the shoe sole of the preserved leg. Conclusions The electromechanical design concept and the resulting knee prosthesis show promising results concerning prosthesis activation during walking tests, thereby showing the feasibility of a reduced manufacturing cost compared to the modern prostheses available on the market.

  9. Static analysis of large-scale multibody system using joint coordinates and spatial algebra operator.

    Omar, Mohamed A

    2014-01-01

    Initial transient oscillations inhibited in the dynamic simulations responses of multibody systems can lead to inaccurate results, unrealistic load prediction, or simulation failure. These transients could result from incompatible initial conditions, initial constraints violation, and inadequate kinematic assembly. Performing static equilibrium analysis before the dynamic simulation can eliminate these transients and lead to stable simulation. Most exiting multibody formulations determine the static equilibrium position by minimizing the system potential energy. This paper presents a new general purpose approach for solving the static equilibrium in large-scale articulated multibody. The proposed approach introduces an energy drainage mechanism based on Baumgarte constraint stabilization approach to determine the static equilibrium position. The spatial algebra operator is used to express the kinematic and dynamic equations of the closed-loop multibody system. The proposed multibody system formulation utilizes the joint coordinates and modal elastic coordinates as the system generalized coordinates. The recursive nonlinear equations of motion are formulated using the Cartesian coordinates and the joint coordinates to form an augmented set of differential algebraic equations. Then system connectivity matrix is derived from the system topological relations and used to project the Cartesian quantities into the joint subspace leading to minimum set of differential equations.

  10. Different techniques in fabrication of ocular prosthesis.

    Cevik, Pinar; Dilber, Erhan; Eraslan, Oguz

    2012-11-01

    Loss of an eye caused by cancer, trauma, or congenital defect creates a deep psychological impact on an individual's life especially social and professional life. Custom-made prosthesis, compared to stock prosthesis, provides a better fit to the eye socket, better cosmetic results, and less discomfort to the patient in the long term. The main objective of this article was to describe 3 different alternative and practical techniques of fabricating custom-made ocular prosthesis. An impression of anophthalmic socket was made with the addition of cured silicone-based precision impression material in all techniques. A master cast was prepared and duplicated with condensation silicone. A self-cure acrylic resin was polymerized in the silicone model and was fitted into the patient's eye socket. A digital photograph of the patient's iris was made using a digital camera and printed on good-quality photo paper in various shades and sizes in the first and the second techniques. Then the photo paper was coated with PVC so as not to allow any color flowing. The proper iris was then inserted to the acrylic base. The prosthesis was final processed using orthodontic heat polymerizing clear acrylic resin.In the other technique, after the trying-in process with wax pattern, an acrylic base was fabricated using heat polymerizing scleral acrylic resin. The prosthetic iris was fabricated from a transparent contact lens by painting the lens with watercolor paints and attaching it to an acrylic resin with tissue conditioner. The final process was made with heat polymerizing transparent acrylic resin. Custom-made prosthesis allows better esthetic and functional results to the patient in comparison to stock prosthesis. Further follow-up is necessary to check the condition and fit of the ocular prosthesis in such patients.

  11. A Low-Complexity Joint Detection-Decoding Algorithm for Nonbinary LDPC-Coded Modulation Systems

    Wang, Xuepeng; Bai, Baoming; Ma, Xiao

    2010-01-01

    In this paper, we present a low-complexity joint detection-decoding algorithm for nonbinary LDPC codedmodulation systems. The algorithm combines hard-decision decoding using the message-passing strategy with the signal detector in an iterative manner. It requires low computational complexity, offers good system performance and has a fast rate of decoding convergence. Compared to the q-ary sum-product algorithm (QSPA), it provides an attractive candidate for practical applications of q-ary LDP...

  12. Prospective randomized controlled trial of an injectable esophageal prosthesis versus a sham procedure for endoscopic treatment of gastroesophageal reflux disease

    Fockens, P.; Cohen, L.; Edmundowicz, S.A.; Binmoeller, K.; Rothstein, R.I.; Smith, D.; Lin, E.; Nickl, N.; Overholt, B.; Kahrilas, P.J.; Vakil, N.; Abdel Aziz Hassan, A.M.; Lehman, G.A.

    2010-01-01

    This study aimed to assess whether endoscopic implantation of an injectable esophageal prosthesis, the Gatekeeper Reflux Repair System (GK), is a safe and effective therapy for controlling gastroesophageal reflux disease (GERD). A prospective, randomized, sham-controlled, single-blinded,

  13. Joint cost of energy under an optimal economic policy of hybrid power systems subject to uncertainty

    Díaz, Guzmán; Planas, Estefanía; Andreu, Jon; Kortabarria, Iñigo

    2015-01-01

    Economical optimization of hybrid systems is usually performed by means of LCoE (levelized cost of energy) calculation. Previous works deal with the LCoE calculation of the whole hybrid system disregarding an important issue: the stochastic component of the system units must be jointly considered. This paper deals with this issue and proposes a new fast optimal policy that properly calculates the LCoE of a hybrid system and finds the lowest LCoE. This proposed policy also considers the implied competition among power sources when variability of gas and electricity prices are taken into account. Additionally, it presents a comparative between the LCoE of the hybrid system and its individual technologies of generation by means of a fast and robust algorithm based on vector logical computation. Numerical case analyses based on realistic data are presented that valuate the contribution of technologies in a hybrid power system to the joint LCoE. - Highlights: • We perform the LCoE calculation with the stochastic component jointly considered. • We propose a fast an optimal policy that minimizes the LCoE. • We compare the obtained LCoEs by means of a fast and robust algorithm. • We take into account the competition among gas prices and electricity prices

  14. CKS knee prosthesis: biomechanics and clinical results in 42 cases.

    Martucci, E; Verni, E; Del Prete, G; Stulberg, S D

    1996-01-01

    From 1991 to 1993 a total of 42 CKS prostheses were implanted for the following reasons: osteoarthrosis (34 cases), rheumatoid arthritis (7 cases) tibial necrosis (1 case). At follow-up obtained after 17 to 41 months the results were: excellent or good: 41; the only poor result was probably related to excessive tension of the posterior cruciate ligament. 94% of the patients reported complete regression of pain, 85% was capable of going up and down stairs without support. Mean joint flexion was 105 degrees. Radiologically the anatomical axis of the knee had a mean valgus of anatomical axis of the knee had a mean valgus of 6 degrees. The prosthetic components were always cemented. The posterior cruciate ligament was removed in 7 knees, so that the prosthesis with "posterior stability" was used. The patella was never prosthetized. One patient complained of peri-patellar pain two months after surgery which then regressed completely.

  15. Joint Symbol Timing and CFO Estimation for OFDM/OQAM Systems in Multipath Channels

    Petrella Angelo

    2010-01-01

    Full Text Available The problem of data-aided synchronization for orthogonal frequency division multiplexing (OFDM systems based on offset quadrature amplitude modulation (OQAM in multipath channels is considered. In particular, the joint maximum-likelihood (ML estimator for carrier-frequency offset (CFO, amplitudes, phases, and delays, exploiting a short known preamble, is derived. The ML estimators for phases and amplitudes are in closed form. Moreover, under the assumption that the CFO is sufficiently small, a closed form approximate ML (AML CFO estimator is obtained. By exploiting the obtained closed form solutions a cost function whose peaks provide an estimate of the delays is derived. In particular, the symbol timing (i.e., the delay of the first multipath component is obtained by considering the smallest estimated delay. The performance of the proposed joint AML estimator is assessed via computer simulations and compared with that achieved by the joint AML estimator designed for AWGN channel and that achieved by a previously derived joint estimator for OFDM systems.

  16. Joint optimal inspection and inventory for a k-out-of-n system

    Bjarnason, Erik T.S.; Taghipour, Sharareh; Banjevic, Dragan

    2014-01-01

    Purpose: The objective of this paper is to develop a model, which optimizes jointly the inspection frequency and the inventory level for a k-out-of-n system with repairable components whose failures are hidden. Scope: The system is periodically inspected to detect failed components, and the components are either minimally repaired or replaced with spares from the inventory. The system fails between periodic inspections if n−k+1 components are down; in that case, all failed components are inspected and rectified if possible. Otherwise, the failed components are rectified at periodic inspections. An emergency spare is ordered at a system failure, if the inventory is empty and all failed components require replacement. Methodology: Using analytical approach to find the optimal solution is computationally intensive and not practical; a simulation model is developed to solve the problem. Results: The proposed model harmonizes the maintenance and inventory policies and finds the joint optimal solution which results in a minimum total cost. Conclusion: The joint optimization model results in a lower cost compared to separate maintenance and inventory optimization models. Novelty: Few joint models for k-out-of-n systems exist, and none of them investigate repairable components whose failures are hidden and follow a non-homogeneous Poisson process. - Highlights: • We model a k-out-of-n system with hidden failures and inventory. • The system is periodically inspected and the inventory is periodically replenished. • Failed components are either replaced or minimally repaired. • A simulation model is developed to calculate the total expected cost. • The inspection interval and inventory level that minimizes the total cost is found

  17. Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.

    Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G

    2012-06-01

    We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.

  18. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  19. The functional relationship between the craniomandibular system, cervical spine, and the sacroiliac joint: a preliminary investigation.

    Fink, Matthias; Wähling, Knut; Stiesch-Scholz, Meike; Tschernitschek, Harald

    2003-07-01

    The hypothesis of a functional coupling between the muscles of the craniomandibular system and the muscles of other body areas is still controversial. The purpose of this pilot study was to examine whether there is a relationship between the craniomandibular system, the craniocervical system and the sacropelvic region. To test this hypothesis, the prevalence and localization of dysfunction of the cervical spine and the sacroiliac joint were examined in a prospective, experimental trial. Twenty healthy students underwent an artificial occlusal interference, which caused an occlusal interference. The upper cervical spine (CO-C3) and the sacroiliac joint were examined before, during and after this experimental test. The primary outcome with these experimental conditions was the occurrence of hypomobile functional abnormalities. In the presence of occlusal interference, functional abnormalities were detected in both regions examined and these changes were statistically significant. The clinical implications of these findings may be that a complementary examination of these areas in CMD patients could be useful.

  20. Towards Establishing a Standardized Magnetic Resonance Imaging Scoring System for Temporomandibular Joints in Juvenile Idiopathic Arthritis

    Tolend, Mirkamal A; Twilt, Marinka; Cron, Randy Q

    2017-01-01

    OBJECTIVES: The temporomandibular joints (TMJs) are frequently affected in children with juvenile idiopathic arthritis (JIA). Early detection is challenging, as major variation is present in scoring TMJ pathology on Magnetic Resonance Imaging (MRI). Consensus-driven development and validation...... of a MRI scoring system for TMJs has important clinical utility in timely improvement of diagnosis, and serving as an outcome measure. We report on a multi-institutional collaboration towards developing a TMJ MRI scoring system for JIA. METHODS: Seven readers independently assessed MRI scans from 21...... preferable for assessing minor joint changes over time. Eight items were considered sufficiently reliable and/or important for integration into the consensus scoring system: bone marrow edema and enhancement (avICC=0.57-0.61; %SDD=±45-63% prior to re-defining), condylar flattening (0.95-0.96; ±23...

  1. A joint FED watermarking system using spatial fusion for verifying the security issues of teleradiology.

    Viswanathan, P; Krishna, P Venkata

    2014-05-01

    Teleradiology allows transmission of medical images for clinical data interpretation to provide improved e-health care access, delivery, and standards. The remote transmission raises various ethical and legal issues like image retention, fraud, privacy, malpractice liability, etc. A joint FED watermarking system means a joint fingerprint/encryption/dual watermarking system is proposed for addressing these issues. The system combines a region based substitution dual watermarking algorithm using spatial fusion, stream cipher algorithm using symmetric key, and fingerprint verification algorithm using invariants. This paper aims to give access to the outcomes of medical images with confidentiality, availability, integrity, and its origin. The watermarking, encryption, and fingerprint enrollment are conducted jointly in protection stage such that the extraction, decryption, and verification can be applied independently. The dual watermarking system, introducing two different embedding schemes, one used for patient data and other for fingerprint features, reduces the difficulty in maintenance of multiple documents like authentication data, personnel and diagnosis data, and medical images. The spatial fusion algorithm, which determines the region of embedding using threshold from the image to embed the encrypted patient data, follows the exact rules of fusion resulting in better quality than other fusion techniques. The four step stream cipher algorithm using symmetric key for encrypting the patient data with fingerprint verification system using algebraic invariants improves the robustness of the medical information. The experiment result of proposed scheme is evaluated for security and quality analysis in DICOM medical images resulted well in terms of attacks, quality index, and imperceptibility.

  2. Metabolic Prosthesis for Oxygenation of Ischemic Tissue

    Greenbaum, Elias [ORNL

    2009-01-01

    This communication discloses new ideas and preliminary results on the development of a "metabolic prosthesis" for local oxygenation of ischemic tissue under physiological neutral conditions. We report for the first time the selective electrolysis of physiological saline by repetitively pulsed charge-limited electrolysis for the production of oxygen and suppression of free chlorine. For example, using 800 A amplitude current pulses and <200 sec pulse durations, we demonstrated prompt oxygen production and delayed chlorine production at the surface of a shiny 0.85 mm diameter spherical platinum electrode. The data, interpreted in terms of the ionic structure of the electric double layer, suggest a strategy for in situ production of metabolic oxygen via a new class of "smart" prosthetic implants for dealing with ischemic disease such as diabetic retinopathy. We also present data indicating that drift of the local pH of the oxygenated environment can be held constant using a feedback-controlled three electrode electrolysis system that chooses anode and cathode pair based on pH data provided by local microsensors. The work is discussed in the context of diabetic retinopathy since surgical techniques for multielectrode prosthetic implants aimed at retinal degenerative diseases have been developed.

  3. Dynamic modeling and optimal joint torque coordination of advanced robotic systems

    Kang, Hee-Jun

    The development is documented of an efficient dynamic modeling algorithm and the subsequent optimal joint input load coordination of advanced robotic systems for industrial application. A closed-form dynamic modeling algorithm for the general closed-chain robotic linkage systems is presented. The algorithm is based on the transfer of system dependence from a set of open chain Lagrangian coordinates to any desired system generalized coordinate set of the closed-chain. Three different techniques for evaluation of the kinematic closed chain constraints allow the representation of the dynamic modeling parameters in terms of system generalized coordinates and have no restriction with regard to kinematic redundancy. The total computational requirement of the closed-chain system model is largely dependent on the computation required for the dynamic model of an open kinematic chain. In order to improve computational efficiency, modification of an existing open-chain KIC based dynamic formulation is made by the introduction of the generalized augmented body concept. This algorithm allows a 44 pct. computational saving over the current optimized one (O(N4), 5995 when N = 6). As means of resolving redundancies in advanced robotic systems, local joint torque optimization is applied for effectively using actuator power while avoiding joint torque limits. The stability problem in local joint torque optimization schemes is eliminated by using fictitious dissipating forces which act in the necessary null space. The performance index representing the global torque norm is shown to be satisfactory. In addition, the resulting joint motion trajectory becomes conservative, after a transient stage, for repetitive cyclic end-effector trajectories. The effectiveness of the null space damping method is shown. The modular robot, which is built of well defined structural modules from a finite-size inventory and is controlled by one general computer system, is another class of evolving

  4. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the temporomandibular...

  5. Adaptive observer for the joint estimation of parameters and input for a coupled wave PDE and infinite dimensional ODE system

    Belkhatir, Zehor; Mechhoud, Sarra; Laleg-Kirati, Taous-Meriem

    2016-01-01

    This paper deals with joint parameters and input estimation for coupled PDE-ODE system. The system consists of a damped wave equation and an infinite dimensional ODE. This model describes the spatiotemporal hemodynamic response in the brain

  6. The effects of static friction and backlash on extended physiological proprioception control of a powered prosthesis.

    Farrell, Todd R; Weir, Richard F; Heckathorne, Craig W; Childress, Dudley S

    2005-01-01

    In general, externally powered prostheses do not provide proprioceptive feedback and thus require the user to rely on cognitively expensive visual feedback to effectively control the prosthesis. Applying the concept of extended physiological proprioception (EPP) to externally powered prostheses provides direct feedback to the user's proprioceptive system regarding the position, velocity, and forces applied to the prosthesis. However, electric elbows with EPP controllers developed at the Northwestern University Prosthetics Research Laboratory have exhibited unexplained "jerky" behavior in both clinical fittings and bench-top operation. In addition, the development of limit cycles, a specific type of constant-amplitude oscillation, had been observed in bench-top use of these elbows. Backlash and static friction within the EPP system were found to be primarily responsible for the development of limit cycles. Reducing static friction and backlash improved the system's performance. These results suggest that to most effectively implement EPP, prosthesis manufacturers should design prosthetic components that minimize static friction and backlash.

  7. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  8. Acromioclavicular joint dislocations: radiological correlation between Rockwood classification system and injury patterns in human cadaver species.

    Eschler, Anica; Rösler, Klaus; Rotter, Robert; Gradl, Georg; Mittlmeier, Thomas; Gierer, Philip

    2014-09-01

    The classification system of Rockwood and Young is a commonly used classification for acromioclavicular joint separations subdividing types I-VI. This classification hypothesizes specific lesions to anatomical structures (acromioclavicular and coracoclavicular ligaments, capsule, attached muscles) leading to the injury. In recent literature, our understanding for anatomical correlates leading to the radiological-based Rockwood classification is questioned. The goal of this experimental-based investigation was to approve the correlation between the anatomical injury pattern and the Rockwood classification. In four human cadavers (seven shoulders), the acromioclavicular and coracoclavicular ligaments were transected stepwise. Radiological correlates were recorded (Zanca view) with 15-kg longitudinal tension applied at the wrist. The resulting acromio- and coracoclavicular distances were measured. Radiographs after acromioclavicular ligament transection showed joint space enlargement (8.6 ± 0.3 vs. 3.1 ± 0.5 mm, p acromioclavicular joint space width increased to 16.7 ± 2.7 vs. 8.6 ± 0.3 mm, p acromioclavicular joint lesions higher than Rockwood type I and II. The clinical consequence for reconstruction of low-grade injuries might be a solely surgical approach for the acromioclavicular ligaments or conservative treatment. High-grade injuries were always based on additional structural damage to the coracoclavicular ligaments. Rockwood type V lesions occurred while muscle attachments were intact.

  9. Enhanced control of a flexure-jointed micromanipulation system using a vision-based servoing approach

    Chuthai, T.; Cole, M. O. T.; Wongratanaphisan, T.; Puangmali, P.

    2018-01-01

    This paper describes a high-precision motion control implementation for a flexure-jointed micromanipulator. A desktop experimental motion platform has been created based on a 3RUU parallel kinematic mechanism, driven by rotary voice coil actuators. The three arms supporting the platform have rigid links with compact flexure joints as integrated parts and are made by single-process 3D printing. The mechanism overall size is approximately 250x250x100 mm. The workspace is relatively large for a flexure-jointed mechanism, being approximately 20x20x6 mm. A servo-control implementation based on pseudo-rigid-body models (PRBM) of kinematic behavior combined with nonlinear-PID control has been developed. This is shown to achieve fast response with good noise-rejection and platform stability. However, large errors in absolute positioning occur due to deficiencies in the PRBM kinematics, which cannot accurately capture flexure compliance behavior. To overcome this problem, visual servoing is employed, where a digital microscopy system is used to directly measure the platform position by image processing. By adopting nonlinear PID feedback of measured angles for the actuated joints as inner control loops, combined with auxiliary feedback of vision-based measurements, the absolute positioning error can be eliminated. With controller gain tuning, fast dynamic response and low residual vibration of the end platform can be achieved with absolute positioning accuracy within ±1 micron.

  10. Implant-Retained Auricular Prosthesis: A Case Report

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  11. Body image and prosthesis satisfaction in the lower limb amputee.

    Murray, Craig; Fox, Jezz

    2002-01-01

    Purpose: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. Method: A total of 44 valid responses were obtained to an Internet survey regarding prosthesis satisfaction, body image, and phantom pain. Spearman Rho correlations were calculated for these three domains. Results: Moderate to high negative correlations were observed between Body Image Disturbance and Prosthesis Sa...

  12. Optimization of Joint Power and Bandwidth Allocation in Multi-Spot-Beam Satellite Communication Systems

    Heng Wang

    2014-01-01

    Full Text Available Multi-spot-beam technique has been widely applied in modern satellite communication systems. However, the satellite power and bandwidth resources in a multi-spot-beam satellite communication system are scarce and expensive; it is urgent to utilize the resources efficiently. To this end, dynamically allocating the power and bandwidth is an available way. This paper initially formulates the problem of resource joint allocation as a convex optimization problem, taking into account a compromise between the maximum total system capacity and the fairness among the spot beams. A joint bandwidth and power allocation iterative algorithm based on duality theory is then proposed to obtain the optimal solution of this optimization problem. Compared with the existing separate bandwidth or power optimal allocation algorithms, it is shown that the joint allocation algorithm improves both the total system capacity and the fairness among spot beams. Moreover, it is easy to be implemented in practice, as the computational complexity of the proposed algorithm is linear with the number of spot beams.

  13. Drugs and Polymers for Delivery Systems in OA Joints: Clinical Needs and Opportunities

    Maarten Janssen

    2014-03-01

    Full Text Available Osteoarthritis (OA is a big burden of disease worldwide and one of the most common causes of disability in the adult population. Currently applied therapies consist of physical therapy, oral medication, intra-articular injections, and surgical interventions, with the main goal being to reduce pain and improve function and quality of life. Intra-articular (IA administration of drugs has potential benefits in OA treatment because it minimizes systemic bioavailability and side effects associated with oral administration of drugs without compromising the therapeutic effect in the joint. However, IA drug residence time is short and there is a clinical need for a vehicle that is able to provide a sustained release long enough for IA therapy to fulfill its promise. This review summarizes the use of different polymeric systems and the incorporated drugs for IA drug delivery in the osteoarthritic joint with a primary focus on clinical needs and opportunities.

  14. 21 CFR 878.3800 - External aesthetic restoration prosthesis.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External aesthetic restoration prosthesis. 878... External aesthetic restoration prosthesis. (a) Identification. An external aesthetic restoration prosthesis... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  15. Fabrication of temporary speech bulb prosthesis: A clinical report

    Kasim Mohamed, K.; Anand Kumar, V.; Devi, N.; Padmanaban, T. V.

    2010-01-01

    Maxillofacial prosthesis is an art and science which not only replaces the lost structure sometimes it restores the functions also. Pharyngeal obturator is a prosthesis which closes the palatal and pharyngeal defects and improving the speech and other function. The following case report discusses palatopharyngeal insufficiency, impression procedures, fabrication of prosthesis and improvements in speech.

  16. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  17. Effects of Neoprene Wrist/Hand Splints on Handwriting for Students with Joint Hypermobility Syndrome: A Single System Design Study

    Frohlich, Lauren; Wesley, Alison; Wallen, Margaret; Bundy, Anita

    2012-01-01

    Purpose: Pain associated with hypermobility of wrist and hand joints can contribute to decreased handwriting output. This study examined the effectiveness of a neoprene wrist/hand splint in reducing pain and increasing handwriting speed and endurance for students with joint hypermobility syndrome. Methods: Multiple baseline, single system design…

  18. Neural network expert system for X-ray analysis of welded joints

    Kozlov, V. V.; Lapik, N. V.; Popova, N. V.

    2018-03-01

    The use of intelligent technologies for the automated analysis of product quality is one of the main trends in modern machine building. At the same time, rapid development in various spheres of human activity is experienced by methods associated with the use of artificial neural networks, as the basis for building automated intelligent diagnostic systems. Technologies of machine vision allow one to effectively detect the presence of certain regularities in the analyzed designation, including defects of welded joints according to radiography data.

  19. Ligament Augmentation and Reconstruction System Failures in Repair of Grade V Acromioclavicular Joint Dislocation

    Martin K.-H. Li

    2017-01-01

    Full Text Available The Ligament Augmentation and Reconstruction System® (LARS® represents a popular synthetic anatomical reduction method for acromioclavicular joint dislocation by means of coracoclavicular ligament reconstruction. To our knowledge, no early failure has been documented in the literature. We present two unusual cases of LARS failure, one at four months after implant and the other at three weeks, without obvious causes, requiring re-do reconstruction, and discuss potential contributory factors.

  20. Cost-Effective Mobile-Based Healthcare System for Managing Total Joint Arthroplasty Follow-Up.

    Bitsaki, Marina; Koutras, George; Heep, Hansjoerg; Koutras, Christos

    2017-01-01

    Long-term follow-up care after total joint arthroplasty is essential to evaluate hip and knee arthroplasty outcomes, to provide information to physicians and improve arthroplasty performance, and to improve patients' health condition. In this paper, we aim to improve the communication between arthroplasty patients and physicians and to reduce the cost of follow-up controls based on mobile application technologies and cloud computing. We propose a mobile-based healthcare system that provides cost-effective follow-up controls for primary arthroplasty patients through questions about symptoms in the replaced joint, questionnaires (WOMAC and SF-36v2) and the radiological examination of knee or hip joint. We also perform a cost analysis for a set of 423 patients that were treated in the University Clinic for Orthopedics in Essen-Werden. The estimation of healthcare costs shows significant cost savings (a reduction of 63.67% for readmission rate 5%) in both the University Clinic for Orthopedics in Essen-Werden and the state of North Rhine-Westphalia when the mobile-based healthcare system is applied. We propose a mHealth system to reduce the cost of follow-up assessments of arthroplasty patients through evaluation of diagnosis, self-monitoring, and regular review of their health status.

  1. Full Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems

    Alessandro De Vita

    2017-07-01

    Full Text Available This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy in order to investigate the seismic performance of reinforced concrete (RC beam-column joints strengthened with steel reinforced polymer (SRP systems. With the aim to represent typical façade frames’ beam-column subassemblies found in existing RC buildings, specimens were provided with two short beam stubs orthogonal to the main beam and were designed with inadequate seismic details. Five members were strengthened by using two different SRP layouts while the remaining ones were used as benchmarks. Once damaged, two specimens were also repaired, retrofitted with SRP, and subjected to cyclic test again. The results of cyclic tests performed on SRP strengthened joints are examined through a comparison with the outcomes of the previous experimental program including companion specimens not provided with transverse beam stubs and strengthened by carbon fiber-reinforced polymer (CFRP systems. In particular, both qualitative and quantitative considerations about the influence of the confining effect provided by the secondary beams on the joint response, the suitability of all the adopted strengthening solutions (SRP/CFRP systems, the performances and the failure modes experienced in the several cases studied are provided.

  2. Full Scale RC Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems

    De Vita, Alessandro; Napoli, Annalisa; Realfonzo, Roberto

    2017-07-01

    This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of RC beam-column joints strengthened with Steel Reinforced Polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in existing RC buildings, specimens were provided with two short beam stubs orthogonal to the main beam and were designed with inadequate seismic details. Five members were strengthened by using two different SRP layouts while the remaining ones were used as benchmarks. Once damaged, two specimens were also repaired, retrofitted with SRP and subjected to cyclic test again. The results of cyclic tests performed on SRP strengthened joints are examined through a comparison with the outcomes of the previous experimental program including companion specimens not provided with transverse beam stubs and strengthened by Carbon Fiber Reinforced Polymer (CFRP) systems. In particular, both qualitative and quantitative considerations about the influence of the confining effect provided by the secondary beams on the joint response, the suitability of all the adopted strengthening solutions (SRP/CFRP systems), the performances and the failure modes experienced in the several cases studied are provided.

  3. [Lessons from a heart valve prosthesis controversy].

    Vandenbroucke, J P; Grobbee, D E

    1998-07-18

    Two lessons are to be learnt from the Björk-Shiley heart valve prosthesis tragedy. In the first place pharmacoepidemiologic studies are seriously hampered by recent privacy legislation. Individual patients carrying such a prosthesis cannot be traced and advised as to their health risks any more, because their legal autonomy has to be respected. This is clearly not to their advantage. In the second place the atmosphere of marketing and litigation and the increasing dependency of researchers on money from sources with conflicting interests is not conducive to a well-informed and balanced judgement of the epidemiological evidence of safety and efficacy of medical treatments.

  4. Efficient optimal joint channel estimation and data detection for massive MIMO systems

    Alshamary, Haider Ali Jasim

    2016-08-15

    In this paper, we propose an efficient optimal joint channel estimation and data detection algorithm for massive MIMO wireless systems. Our algorithm is optimal in terms of the generalized likelihood ratio test (GLRT). For massive MIMO systems, we show that the expected complexity of our algorithm grows polynomially in the channel coherence time. Simulation results demonstrate significant performance gains of our algorithm compared with suboptimal non-coherent detection algorithms. To the best of our knowledge, this is the first algorithm which efficiently achieves GLRT-optimal non-coherent detections for massive MIMO systems with general constellations.

  5. Experiences from the Architectural Migration of a Joint Replacement Surgery Information System

    Samuli Niiranen

    2008-01-01

    Full Text Available The goal of this study is to present the experiences gathered from the migration of an existing and deployed joint replacement surgery information system from a classical 2-tier architecture to a 4-tier architecture. These include discussion on the motivation for the migration and on the technical benefits of the chosen technical migration path and an evaluation of user experiences. The results from the analysis of clinical end-user and administrator experiences show an increase in the perceived performance and maintainability of the system and a high level of acceptance for the new system version.

  6. DAS, Uncoordinated Femto and Joint Scheduling Systems for In-Building Wireless Solutions

    Liu, Zhen; Sørensen, Troels Bundgaard; Wigard, Jeoren

    2011-01-01

    -data-rate services. Distributed antenna systems and Femto cells are cost-efficient techniques for this application. In this paper, their performance is evaluated in an LTE downlink context along with a proposed joint scheduling system, which maximizes the supported number of users under a QoS constraint....... The selection of the enterprise building model includes a general office building model described in the WINNER II project and a site-specific office building with large scale path-loss values retrieved from measurements. Results show superior performance of the Femto system compared to DAS in providing high...

  7. Active Bone Conduction Prosthesis: BonebridgeTM

    Zernotti, Mario E.

    2015-10-01

    Full Text Available Introduction Bone conduction implants are indicated for patients with conductive and mixed hearing loss, as well as for patients with single-sided deafness (SSD. The transcutaneous technology avoids several complications of the percutaneous bone conduction implants including skin reaction, skin growth over the abutment, and wound infection. The Bonebridge (MED-EL, Austria prosthesis is a semi-implantable hearing system: the BCI (Bone Conduction Implant is the implantable part that contains the Bone Conduction-Floating Mass Transducer (BC-FMT, which applies the vibrations directly to the bone; the external component is the audio processor Amadé BB (MED-EL, Austria, which digitally processes the sound and sends the information through the coil to the internal part. Bonebridge may be implanted through three different approaches: the transmastoid, the retrosigmoid, or the middle fossa approach. Objective This systematic review aims to describe the world́s first active bone conduction implant system, Bonebridge, as well as describe the surgical techniques in the three possible approaches, showing results from implant centers in the world in terms of functional gain, speech reception thresholds and word recognition scores. Data Synthesis The authors searched the MEDLINE database using the key term Bonebridge. They selected only five publications to include in this systematic review. The review analyzes 20 patients that received Bonebridge implants with different approaches and pathologies. Conclusion Bonebridge is a solution for patients with conductive/mixed hearing loss and SSD with different surgical approaches, depending on their anatomy. The system imparts fewer complications than percutaneous bone conduction implants and shows proven benefits in speech discrimination and functional gain.

  8. Joint Instability and Osteoarthritis

    Darryl Blalock

    2015-01-01

    Full Text Available Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA. Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  9. Joint instability and osteoarthritis.

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  10. Morphodynamic study of haemophilic joint diseases with the scintillation camera and a whole-body scintigraphy system

    Koutoulidis, C.; Papathanassiou, B.T.; Kambouroglou, G.; Louisou, C.; Mandalaki, T.

    1975-01-01

    Joint lesions in haemophilics were studied with a new whole-body scintigraphic system which combines the scintillation camera and an automatic travelling table. The results obtained are compared with clinical and radiographic data and an attempt is made to explain the mechanism of tracer uptake (sup(99m)Tc-tin-pyrophosphate) on the lesions. This system is found to offer great advantages over traditional systems for the study of haemophilic joint diseases since all the joints affected can be estimated in a very short time, a very important point in following the progress of the lesion, preventing relapses and checking the efficiency of the treatment [fr

  11. Joint interval reliability for Markov systems with an application in transmission line reliability

    Csenki, Attila

    2007-01-01

    We consider Markov reliability models whose finite state space is partitioned into the set of up states U and the set of down states D . Given a collection of k disjoint time intervals I l =[t l ,t l +x l ], l=1,...,k, the joint interval reliability is defined as the probability of the system being in U for all time instances in I 1 union ... union I k . A closed form expression is derived here for the joint interval reliability for this class of models. The result is applied to power transmission lines in a two-state fluctuating environment. We use the Linux versions of the free packages Maxima and Scilab in our implementation for symbolic and numerical work, respectively

  12. Joint interval reliability for Markov systems with an application in transmission line reliability

    Csenki, Attila [School of Computing and Mathematics, University of Bradford, Bradford, West Yorkshire, BD7 1DP (United Kingdom)]. E-mail: a.csenki@bradford.ac.uk

    2007-06-15

    We consider Markov reliability models whose finite state space is partitioned into the set of up states {sub U} and the set of down states {sub D}. Given a collection of k disjoint time intervals I{sub l}=[t{sub l},t{sub l}+x{sub l}], l=1,...,k, the joint interval reliability is defined as the probability of the system being in {sub U} for all time instances in I{sub 1} union ... union I{sub k}. A closed form expression is derived here for the joint interval reliability for this class of models. The result is applied to power transmission lines in a two-state fluctuating environment. We use the Linux versions of the free packages Maxima and Scilab in our implementation for symbolic and numerical work, respectively.

  13. Recent Joint Studies Related to the Development of Space Radioisotope Power Systems

    Kramer Daniel P.

    2017-01-01

    Full Text Available Over the last several years there has been a mutually beneficial ongoing technical interchange between the U.K and the U.S. related to various aspects of space radioisotope power systems (RPS. While this interchange has been primarily focused on materials based activities, it has also included some aspects related to safety, environmental, and lessons learned during the application of RPSs by the U.S. during the last fifty years. Recent joint technical RPS endeavors have centered on the development of a possible “cold” ceramic surrogate for 238PuO2 and 241AmOx and the irradiation of thermoelectrics and other materials at expected RPS related neutron fluences. As the U.S. continues to deploy and Europe develops RPS capability, on-going joint RPS technical interfaces will continue to enhance each entities’ endeavors in this nuclear based power technology critical for deep space exploration.

  14. The method of a joint intraday security check system based on cloud computing

    Dong, Wei; Feng, Changyou; Zhou, Caiqi; Cai, Zhi; Dan, Xu; Dai, Sai; Zhang, Chuancheng

    2017-01-01

    The intraday security check is the core application in the dispatching control system. The existing security check calculation only uses the dispatch center’s local model and data as the functional margin. This paper introduces the design of all-grid intraday joint security check system based on cloud computing and its implementation. To reduce the effect of subarea bad data on the all-grid security check, a new power flow algorithm basing on comparison and adjustment with inter-provincial tie-line plan is presented. And the numerical example illustrated the effectiveness and feasibility of the proposed method.

  15. The control system for the multiple-pellet injector on the Joint European Torus

    Baylor, L.R.; Jernigan, T.C.; Stewart, K.A.

    1989-01-01

    A stand-alone control and data acquisition system for the Oak Ridge National Laboratory (ORNL) multiple-pellet injector installed on the Joint European Torus (JET) has been designed and installed with the injector. This system, which is based on a MicroVAX II computer and a programmable logic controller (PLC), is an upgrade of previous systems designed for ORNL pellet injectors installed on other fusion experiments. The primary control system upgrades are in the user interface, in the automation of sequential injector operation, and in the analysis of the transient data acquired for each pellet fired. The system is integrated into the JET CODAS environment through CAMAC communications modules with customized communications software. Routine operation of the injector is automated and requires no operator intervention. Details of the hardware and software design and the operation of the system are presented in this paper. 4 refs., 3 figs

  16. Joint inventory control and pricing in a service-inventory system

    Marand, Ata Jalili; Li, Hongyan Jenny; Thorstenson, Anders

    2017-01-01

    This study addresses joint inventory control and pricing decisions for a service-inventory system. In such a system both an on-hand inventory item and a positive service time are required to fulfill customer demands. The service-inventory system also captures main features of the classical...... inventory systems with a positive processing time, e.g., make-to-order systems. In this study, the service-inventory system is modeled as an M/M/1 queue in which the customer arrival rate is price dependent. The inventory of an individual item is continuously reviewed under an (r,Q) policy....... The replenishment lead times of the inventory are exponentially distributed. Furthermore, customers arriving during stock-out periods are lost. The stochastic customer inter-arrival times, service times, and inventory replenishment lead times cause the high complexity of the problem and the difficulty in solving it...

  17. Distal corporoplasty for distal cylinders extrusion after penile prosthesis implantation.

    Carrino, Maurizio; Chiancone, Francesco; Battaglia, Gaetano; Pucci, Luigi; Fedelini, Paolo

    2017-02-03

    Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Several methods have been proposed for repairing a distal penile erosion. We present our preliminary experience in "Distal corporoplasty" technique. We enrolled 18 consecutive patients whose underwent a distal corporoplasty with simultaneous reimplantation of an "AMS 700 inflatable penile prosthesis (LGX)" from January 2013 to November 2015 at our hospital. All procedures were performed by a single surgical team. Intraoperative and postoperative complications have been classified and reported according to Satava6 and Clavien-Dindo (CD) system.7 Mean values with standard deviations (±SD) were computed and reported for all items. Mean age of the patients was 53.61 (±11.90) years. Mean body max index (BMI) was 24.22 (±2.51). Mean operative time was 85.2 (±13.1) minutes. Blood losses were minimal. No intraoperative complications are reported according to Satava classification. Four out of 18 patients (22.22%) experienced postoperative complications according to CD system. All patients had sexual intercourse for the first time postsurgery after a mean of 59.11 ± 2.08 days. Mean follow-up was 22.11 (±9.95). Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Distal corporoplasty was first described by Mulcahy. He reported a series of 14 patients with a follow-up of about 2 years with optimal functional outcomes. Moreover, distal corporoplasty resulted in shorter operative time, better function, less pain, and fewer recurrences than Gortex windsock repair.10 In our experience, distal corporoplasty is a simple and safe procedure in the treatment of distal cylinders extrusion when the prosthetic material is not exposed to the exterior.

  18. Clinical Outcomes of Penile Prosthesis Implantation Surgery

    Onur Dede

    2016-06-01

    Full Text Available Objective: We aimed to evaluating the outcomes of in­flatable penile prosthesis implantations and partner sat­isfaction. Methods: Data of 52 patients who underwent penile prosthesis implantation in single center between May 2010 and December 2015 were retrospectively analyzed. Types of prosthesis, complication and satisfaction rates of patients were recorded by EDITS (Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire was used. Results: The mean age was 49.2±14.7 years for patients. The mean follow-up durations for 34.3±12.5 months. The mean hospital stay was 3.84±1.52 days. Evaluating of the couples satisfaction revealed that 44 (84% of the patient were very satisfied. There was not any complication and no patient need to underwent revision surgery. Conclusion: Inflatable penile prosthesis implants, with high levels of treatment success, patient and partner sat­isfaction, are effective and safe options for treatment of organic erectile dysfunction with acceptable complication and revision rates.

  19. Case Report: Magnetically retained silicone facial prosthesis ...

    Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention. Key words: Magnet ...

  20. Fusion around cervical disc prosthesis: case report.

    Bartels, R.H.M.A.; Donk, R.

    2005-01-01

    OBJECTIVE AND IMPORTANCE: Cervical arthroplasty is a relatively new method to maintain motion after cervical anterior discectomy. Two cases are presented in which bony fusion occurred around a cervical disc prosthesis. CLINICAL PRESENTATION: A 30-year-old man and a 49-year-old woman underwent a

  1. Comparison of Range of Motion After Total Knee Prosthesis According to Different Type of Prosthesis

    Firat Seyfettinoglu

    2016-07-01

    Full Text Available Aim: The aim of this study is to determine the effectiveness and range of motion of different type of knee prosthesis. Material and Method: This study includes 180 of 225 patients (139 F, 41 M, average age: 65, range of age: 51-82 between April 2005 and September 2007 with the diagnosis of gonarthrosis. All patients underwent to primary total knee arthroplasty. Primary osteoartrhritis is the reason of gonarthrosis. The patients with secondary osteoartrhritis were excluded from the study. All the patients were operated by the same surgical team and rehabilitated after surgery. Patella didnt change any patient. PCL was protected in some of the patients and cut some of patients. Totally seven type prosthesis in 16 subgroup were applied to the patients. All measurement were done by the same surgeon. Average follow up period was 31 months (24-49 months. Results: Patients without subgrouping were tested according to the range of motion before and after surgery to the type of the prosthesis trademark. Range of motion was decreased with the usage of Rotaglide and LCS® type of prosthesis. Range of motion didnt change with the usage of Maxim and Kinemax type. The range of motion increased in the other trademark of prosthesis. Flexion angle was increased statistically significant with nexgen® and scorpio® prosthesis (p

  2. Hearing results using the SMart piston prosthesis.

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  3. Estimation of soil salinity in a drip irrigation system by using joint inversion of multicoil electromagnetic induction measurements

    Jadoon, Khan Zaib; Moghadas, Davood; Jadoon, Aurangzeb; Missimer, Thomas M.; Al-Mashharawi, Samir K.; McCabe, Matthew

    2015-01-01

    -Explorer) is used for subsurface characterization of soil salinity in a drip irrigation system via a joint inversion approach of multiconfiguration EMI measurements. EMI measurements were conducted across a farm where Acacia trees are irrigated with brackish water

  4. Joint redundancy and imperfect preventive maintenance optimization for series–parallel multi-state degraded systems

    Nourelfath, Mustapha; Châtelet, Eric; Nahas, Nabil

    2012-01-01

    This paper formulates a joint redundancy and imperfect preventive maintenance planning optimization model for series–parallel multi-state degraded systems. Non identical multi-state components can be used in parallel to improve the system availability by providing redundancy in subsystems. Multiple component choices are available in the market for each subsystem. The status of each component is considered to degrade with use. The objective is to determine jointly the maximal-availability series–parallel system structure and the appropriate preventive maintenance actions, subject to a budget constraint. System availability is defined as the ability to satisfy consumer demand that is represented as a piecewise cumulative load curve. A procedure is used, based on Markov processes and universal moment generating function, to evaluate the multi-state system availability and the cost function. A heuristic approach is also proposed to solve the formulated problem. This heuristic is based on a combination of space partitioning, genetic algorithms (GA) and tabu search (TS). After dividing the search space into a set of disjoint subsets, this approach uses GA to select the subspaces, and applies TS to each selected sub-space.

  5. Generalized formulation of an encryption system based on a joint transform correlator and fractional Fourier transform

    Vilardy, Juan M; Millán, María S; Pérez-Cabré, Elisabet; Torres, Yezid

    2014-01-01

    We propose a generalization of the encryption system based on double random phase encoding (DRPE) and a joint transform correlator (JTC), from the Fourier domain to the fractional Fourier domain (FrFD) by using the fractional Fourier operators, such as the fractional Fourier transform (FrFT), fractional traslation, fractional convolution and fractional correlation. Image encryption systems based on a JTC architecture in the FrFD usually produce low quality decrypted images. In this work, we present two approaches to improve the quality of the decrypted images, which are based on nonlinear processing applied to the encrypted function (that contains the joint fractional power spectrum, JFPS) and the nonzero-order JTC in the FrFD. When the two approaches are combined, the quality of the decrypted image is higher. In addition to the advantages introduced by the implementation of the DRPE using a JTC, we demonstrate that the proposed encryption system in the FrFD preserves the shift-invariance property of the JTC-based encryption system in the Fourier domain, with respect to the lateral displacement of both the key random mask in the decryption process and the retrieval of the primary image. The feasibility of this encryption system is verified and analyzed by computer simulations. (paper)

  6. A joint-space numerical model of metabolic energy expenditure for human multibody dynamic system.

    Kim, Joo H; Roberts, Dustyn

    2015-09-01

    Metabolic energy expenditure (MEE) is a critical performance measure of human motion. In this study, a general joint-space numerical model of MEE is derived by integrating the laws of thermodynamics and principles of multibody system dynamics, which can evaluate MEE without the limitations inherent in experimental measurements (phase delays, steady state and task restrictions, and limited range of motion) or muscle-space models (complexities and indeterminacies from excessive DOFs, contacts and wrapping interactions, and reliance on in vitro parameters). Muscle energetic components are mapped to the joint space, in which the MEE model is formulated. A constrained multi-objective optimization algorithm is established to estimate the model parameters from experimental walking data also used for initial validation. The joint-space parameters estimated directly from active subjects provide reliable MEE estimates with a mean absolute error of 3.6 ± 3.6% relative to validation values, which can be used to evaluate MEE for complex non-periodic tasks that may not be experimentally verifiable. This model also enables real-time calculations of instantaneous MEE rate as a function of time for transient evaluations. Although experimental measurements may not be completely replaced by model evaluations, predicted quantities can be used as strong complements to increase reliability of the results and yield unique insights for various applications. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Joint Polar Satellite System: the United States New Generation Civilian Polar Orbiting Environmental Satellite System

    Mandt, G.

    2017-12-01

    The Joint Polar Satellite System (JPSS) is the Nation's advanced series of polar-orbiting environmental satellites. JPSS represents significant technological and scientific advancements in observations used for severe weather prediction and environmental monitoring. The Suomi National Polar-orbiting Partnership (S-NPP) is providing state-of-the art atmospheric, oceanographic, and environmental data, as the first of the JPSS satellites while the second in the series, J-1, is scheduled to launch in October 2017. The JPSS baseline consists of a suite of four instruments: an advanced microwave and infrared sounders which are critical for weather forecasting; a leading-edge visible and infrared imager critical to data sparse areas such as Alaska and needed for environmental assessments such as snow/ice cover, droughts, volcanic ash, forest fires and surface temperature; and an ozone sensor primarily used for global monitoring of ozone and input to weather and climate models. The same suite of instruments that are on JPSS-1 will be on JPSS-2, 3 and 4. The JPSS-2 instruments are well into their assembly and test phases and are scheduled to be completed in 2018. The JPSS-2 spacecraft critical design review (CDR) is scheduled for 2Q 2018 with the launch in 2021. The sensors for the JPSS-3 and 4 spacecraft have been approved to enter into their acquisition phases. JPSS partnership with the US National Aeronautics and Space Agency (NASA) continues to provide a strong foundation for the program's success. JPSS also continues to maintain its important international relationships with European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT) and the Japan Aerospace Exploration Agency (JAXA). JPSS works closely with its user community through the Proving Ground and Risk Reduction (PGRR) Program to identify opportunities to maximize the operational application of current JPSS capabilities. The PGRR Program also helps identify and evaluate the use of JPSS

  8. Game-Based Rehabilitation for Myoelectric Prosthesis Control.

    Prahm, Cosima; Vujaklija, Ivan; Kayali, Fares; Purgathofer, Peter; Aszmann, Oskar C

    2017-02-09

    A high number of upper extremity myoelectric prosthesis users abandon their devices due to difficulties in prosthesis control and lack of motivation to train in absence of a physiotherapist. Virtual training systems, in the form of video games, provide patients with an entertaining and intuitive method for improved muscle coordination and improved overall control. Complementary to established rehabilitation protocols, it is highly beneficial for this virtual training process to start even before receiving the final prosthesis, and to be continued at home for as long as needed. The aim of this study is to evaluate (1) the short-term effects of a commercially available electromyographic (EMG) system on controllability after a simple video game-based rehabilitation protocol, and (2) different input methods, control mechanisms, and games. Eleven able-bodied participants with no prior experience in EMG control took part in this study. Participants were asked to perform a surface EMG test evaluating their provisional maximum muscle contraction, fine accuracy and isolation of electrode activation, and endurance control over at least 300 seconds. These assessments were carried out (1) in a Pregaming session before interacting with three EMG-controlled computer games, (2) in a Postgaming session after playing the games, and (3) in a Follow-Up session two days after the gaming protocol to evaluate short-term retention rate. After each game, participants were given a user evaluation survey for the assessment of the games and their input mechanisms. Participants also received a questionnaire regarding their intrinsic motivation (Intrinsic Motivation Inventory) at the end of the last game. Results showed a significant improvement in fine accuracy electrode activation (Pgames when collecting items and facing challenging game play. Most upper limb amputees use a 2-channel myoelectric prosthesis control. This study demonstrates that this control can be effectively trained by

  9. Experimental effective shape control of a powered transfemoral prosthesis.

    Gregg, Robert D; Lenzi, Tommaso; Fey, Nicholas P; Hargrove, Levi J; Sensinger, Jonathon W

    2013-06-01

    This paper presents the design and experimental implementation of a novel feedback control strategy that regulates effective shape on a powered transfemoral prosthesis. The human effective shape is the effective geometry to which the biological leg conforms--through movement of ground reaction forces and leg joints--during the stance period of gait. Able-bodied humans regulate effective shapes to be invariant across conditions such as heel height, walking speed, and body weight, so this measure has proven to be a very useful tool for the alignment and design of passive prostheses. However, leg joints must be actively controlled to assume different effective shapes that are unique to tasks such as standing, walking, and stair climbing. Using our previous simulation studies as a starting point, we model and control the effective shape as a virtual kinematic constraint on the powered Vanderbilt prosthetic leg with a custom instrumented foot. An able-bodied subject used a by-pass adapter to walk on the controlled leg over ground and over a treadmill. These preliminary experiments demonstrate, for the first time, that effective shape (or virtual constraints in general) can be used to control a powered prosthetic leg.

  10. Converging flow joint insert system at an intersection between adjacent transitions extending between a combustor and a turbine assembly in a gas turbine engine

    Wiebe, David J.; Carlson, Andrew; Stoker, Kyle C.

    2017-10-31

    A transition duct system for routing a gas flow in a combustion turbine engine is provided. The transition duct system includes one or more converging flow joint inserts forming a trailing edge at an intersection between adjacent transition ducts. The converging flow joint insert may be contained within a converging flow joint insert receiver and may be disconnected from the transition duct bodies by which the converging flow joint insert is positioned. Being disconnected eliminates stress formation within the converging flow joint insert, thereby enhancing the life of the insert. The converging flow joint insert may be removable such that the insert can be replaced once worn beyond design limits.

  11. A network and visual quality aware N-screen content recommender system using joint matrix factorization.

    Ullah, Farman; Sarwar, Ghulam; Lee, Sungchang

    2014-01-01

    We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service) in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user's N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user's N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues.

  12. Joint nonlinearity effects in the design of a flexible truss structure control system

    Mercadal, Mathieu

    1986-01-01

    Nonlinear effects are introduced in the dynamics of large space truss structures by the connecting joints which are designed with rather important tolerances to facilitate the assembly of the structures in space. The purpose was to develop means to investigate the nonlinear dynamics of the structures, particularly the limit cycles that might occur when active control is applied to the structures. An analytical method was sought and derived to predict the occurrence of limit cycles and to determine their stability. This method is mainly based on the quasi-linearization of every joint using describing functions. This approach was proven successful when simple dynamical systems were tested. Its applicability to larger systems depends on the amount of computations it requires, and estimates of the computational task tend to indicate that the number of individual sources of nonlinearity should be limited. Alternate analytical approaches, which do not account for every single nonlinearity, or the simulation of a simplified model of the dynamical system should, therefore, be investigated to determine a more effective way to predict limit cycles in large dynamical systems with an important number of distributed nonlinearities.

  13. A Network and Visual Quality Aware N-Screen Content Recommender System Using Joint Matrix Factorization

    Farman Ullah

    2014-01-01

    Full Text Available We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user’s N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user’s N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues.

  14. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening

    Wang, Weiya; Jia, Mengyu; Gao, Feng; Yang, Lihong; Qu, Pengpeng; Zou, Changping; Liu, Pengxi; Zhao, Huijuan

    2015-02-01

    The cervical cancer screening at a pre-cancer stage is beneficial to reduce the mortality of women. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening is introduced in this paper. In this system, three electrodes alternately discharge to the cervical tissue and three light emitting diodes in different wavelengths alternately irradiate the cervical tissue. Then the relative optical reflectance and electrical voltage attenuation curve are obtained by optical and electrical detection, respectively. The system is based on DSP to attain the portable and cheap instrument. By adopting the relative reflectance and the voltage attenuation constant, the classification algorithm based on Support Vector Machine (SVM) discriminates abnormal cervical tissue from normal. We use particle swarm optimization to optimize the two key parameters of SVM, i.e. nuclear factor and cost factor. The clinical data were collected on 313 patients to build a clinical database of tissue responses under optical and electrical stimulations with the histopathologic examination as the gold standard. The classification result shows that the opto-electronic joint detection has higher total coincidence rate than separate optical detection or separate electrical detection. The sensitivity, specificity, and total coincidence rate increase with the increasing of sample numbers in the training set. The average total coincidence rate of the system can reach 85.1% compared with the histopathologic examination.

  15. Manual for IRS Coding. Joint IAEA/NEA International Reporting System for Operating Experience

    2011-01-01

    The International Reporting System for Operating Experience (IRS) is jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). In early 2010, the IAEA and OECD/NEA jointly issued the IRS Guidelines, which described the reporting system and process and gave users the necessary elements to enable them to produce IRS reports to a high standard of quality while retaining the effectiveness of the system expected by all Member States operating nuclear power plants. The purpose of the present Manual for IRS Coding is to provide supplementary guidance specifically on the coding element of IRS reports to ensure uniform coding of events that are reported through IRS. This Coding Manual does not supersede the IRS Guidelines, but rather, supports users and preparers in achieving a consistent and high level of quality in their IRS reports. Consistency and high quality in the IRS reports allow stakeholders to search and retrieve specific event information with ease. In addition, well-structured reports also enhance the efficient management of the IRS database. This Coding Manual will give specific guidance on the application of each section of the IRS codes, with examples where necessary, of when and how these codes are to be applied. As this reporting system is owned by the Member States, this manual has been developed and approved by the IRS National Coordinators with the assistance of the IAEA and NEA secretariats

  16. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  17. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    Kwon, JaeWoo; Park, Kihong; Ko, Youngchai; Yang, Hongchuan

    2012-01-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  18. 2001 Joint ADVISOR/PSAT Vehicle Systems Modeling User's Conference Proceedings (CD)

    Markel, T.

    2001-01-01

    The 2001 Joint ADVISOR/PSAT Vehicle Systems Modeling User Conference provided an opportunity for engineers in the automotive industry and the research environment to share their experiences in vehicle systems modeling using ADVISOR and PSAT. ADVISOR and PSAT are vehicle systems modeling tools developed and supported by the National Renewable Energy Laboratory and Argonne National Laboratory respectively with the financial support of the US Department of Energy. During this conference peers presented the results of studies using the simulation tools and improvements that they have made or would like to see in the simulation tools. Focus areas of the presentations included Control Strategy, Model Validation, Optimization and Co-Simulation, Model Development, Applications, and Fuel Cell Vehicle Systems Analysis. Attendees were offered the opportunity to give feedback on future model development plans

  19. 2001 Joint ADVISOR/PSAT Vehicle Systems Modeling User's Conference Proceedings (CD)

    Markel, T.

    2001-08-01

    The 2001 Joint ADVISOR/PSAT Vehicle Systems Modeling User Conference provided an opportunity for engineers in the automotive industry and the research environment to share their experiences in vehicle systems modeling using ADVISOR and PSAT. ADVISOR and PSAT are vehicle systems modeling tools developed and supported by the National Renewable Energy Laboratory and Argonne National Laboratory respectively with the financial support of the US Department of Energy. During this conference peers presented the results of studies using the simulation tools and improvements that they have made or would like to see in the simulation tools. Focus areas of the presentations included Control Strategy, Model Validation, Optimization and Co-Simulation, Model Development, Applications, and Fuel Cell Vehicle Systems Analysis. Attendees were offered the opportunity to give feedback on future model development plans.

  20. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    Kwon, JaeWoo

    2012-10-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  1. "Joint Workshop on High Confidence Medical Devices, Software, and Systems (HCMDSS) and Medical Device Plug-and-Play (MD PnP) Interoperability"

    Goldman, Julian M

    2008-01-01

    Partial support was requested from TATRC, with joint funding from NSF, for a joint workshop to bring together the synergistic efforts and communities of the High Confidence Medical Devices, Software, and Systems (HCMDSS...

  2. Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system

    Seslija, Petar; Teeter, Matthew G.; Yuan Xunhua; Naudie, Douglas D. R.; Bourne, Robert B.; MacDonald, Steven J.; Peters, Terry M.; Holdsworth, David W.

    2012-01-01

    Purpose: The ability to accurately measure joint kinematics is an important tool in studying both normal joint function and pathologies associated with injury and disease. The purpose of this study is to evaluate the efficacy, accuracy, precision, and clinical safety of measuring 3D joint motion using a conventional flat-panel radiography system prior to its application in an in vivo study. Methods: An automated, image-based tracking algorithm was implemented to measure the three-dimensional pose of a sparse object from a two-dimensional radiographic projection. The algorithm was tested to determine its efficiency and failure rate, defined as the number of image frames where automated tracking failed, or required user intervention. The accuracy and precision of measuring three-dimensional motion were assessed using a robotic controlled, tibiofemoral knee phantom programmed to mimic a subject with a total knee replacement performing a stair ascent activity. Accuracy was assessed by comparing the measurements of the single-plane radiographic tracking technique to those of an optical tracking system, and quantified by the measurement discrepancy between the two systems using the Bland–Altman technique. Precision was assessed through a series of repeated measurements of the tibiofemoral kinematics, and was quantified using the across-trial deviations of the repeated kinematic measurements. The safety of the imaging procedure was assessed by measuring the effective dose of ionizing radiation associated with the x-ray exposures, and analyzing its relative risk to a human subject. Results: The automated tracking algorithm displayed a failure rate of 2% and achieved an average computational throughput of 8 image frames/s. Mean differences between the radiographic and optical measurements for translations and rotations were less than 0.08 mm and 0.07° in-plane, and 0.24 mm and 0.6° out-of-plane. The repeatability of kinematics measurements performed using the

  3. MMSE-based algorithm for joint signal detection, channel and noise variance estimation for OFDM systems

    Savaux, Vincent

    2014-01-01

    This book presents an algorithm for the detection of an orthogonal frequency division multiplexing (OFDM) signal in a cognitive radio context by means of a joint and iterative channel and noise estimation technique. Based on the minimum mean square criterion, it performs an accurate detection of a user in a frequency band, by achieving a quasi-optimal channel and noise variance estimation if the signal is present, and by estimating the noise level in the band if the signal is absent. Organized into three chapters, the first chapter provides the background against which the system model is pr

  4. Rehabilitation with ear prosthesis linked to osseointegrated implants.

    Goiato, Marcelo C; dos Santos, Daniela M; Haddad, Marcela F; Moreno, Amália

    2012-06-01

    The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment. The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants. The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system. The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  5. Assessment of the Temporomandibular Joint Function in Young Adults without Complaints from the Masticatory System.

    Kondrat, Wojciech; Sierpińska, Teresa; Radke, John

    2018-01-01

    Objective of the study was to evaluate the clinical status of the masticatory system in young adults with full permanent dentition and no stomatognathic system complaints. The study involved 186 randomly selected people with full dental arches with normal occlusal conditions corresponding to Angle's Class I aged 18 - 21 years with an average age of 19 years. Subjects were clinically examined and temporomandibular joint (TMJ) vibrations were recorded during open-wide and close movements using BioJVA. Then, patients were categorized into groups according to Piper's classification system. The TMJs of the subjects were categorized according to the values of the vibration energy and the Piper protocol. This detected 33.4% of the joints with loosened ligaments, subluxation in 8.28%, initial signs of disc dysfunction in 5.08% and disc displacement without locking in 1.6 %. Median frequency differed significantly (p vibrations. However, a subset of people manifested higher vibrations that may indicate an early stage of TMJ dysfunction. Median Frequency was an important parameter for detecting initial symptoms of TMJ dysfunction. Peak Frequency was an important characteristic parameter for detecting TMJ subluxation.

  6. FE Modelling of the Seismic Behavior of Wide Beam-Column Joints Strengthened with CFRP Systems

    Giuseppe Santarsiero

    2018-02-01

    Full Text Available A large share of reinforced concrete (RC framed buildings is provided with wide beams being a type of beam allowing greater freedom in the architectural arrangement of interiors, beyond further advantage due to fewer formworks needed during the construction. Nevertheless, little attention has been devoted to the seismic vulnerability of this kind of framed RC buildings as well as to the study of strengthening systems purposely developed for wide beams and wide beam-column connections. Under these premises, this paper proposes simple strengthening solutions made by Fibre Reinforced Polymers (FRP systems able to effectively improve seismic capacity through feasible arrangement suitable in case a wide beam is present. On the basis of wide beam-column joints previously tested without strengthening system, detailed nonlinear finite element models were calibrated. Then, an FRP strengthening intervention based on a brand new arrangement was modeled in order to perform additional simulations under seismic actions. This way, the effectiveness of the strengthening intervention was assessed finding out that significant strength and ductility increments were achieved with a relatively simple and cheap strengthening arrangement. Additional research would be desirable in the form of experimental tests on the simulated wide beam-column joints.

  7. A digital-signal-processor-based optical tomographic system for dynamic imaging of joint diseases

    Lasker, Joseph M.

    joint diseases, especially effects of rheumatoid arthritis (RA) in the proximal interphalangeal finger joints. Using a dual-wavelength tomographic imaging system and previously implemented reconstruction scheme, I have performed initial dynamic imaging case studies on healthy volunteers and patients diagnosed with RA. These studies support our hypothesis that differences in the vascular and metabolic reactivity exist between affected and unaffected joints and can be used for diagnostic purposes.

  8. Retrospective Study on External Canine Limb Prosthesis used in 24 patients

    Brittany Jean Carr

    2018-03-01

    Full Text Available Objective: The purpose of this retrospective study is to provide data regarding external prosthetic use in small animal patients, evaluate the common complications associated with external prosthetics, and evaluate the outcome of patients using an external prosthetic.Background: The use of external canine limb prosthetics is relatively uncommon in veterinary medicine today.  However, there is growing interest in prosthetics and their clinical application because these devices may offer an alternative to euthanasia in severe cases where full amputation or alternative methods of limb spare are not an option. The goal of the prosthesis is to provide a better quality of life, help prevent further deformation and degeneration of existing joints, decrease leg length discrepancies, increase exercise and activity levels, provide a means to participate in rehabilitation therapy and maintain the ability to perform daily acts of living. To the author’s knowledge, there is no report of external prosthetic use in small animal veterinary medicine, providing the profession with baseline information for use in, not only general practice or referral practice, but also future research.Evidentiary value: This retrospective study provides data regarding external prosthetic use in small animal patients, evaluates the procedures, manufacturing, rehabilitation and common complications associated with external prosthetics, and evaluates the factors that determine a patient’s prosthetic candidacy.Methods: Patients that had an external prosthesis custom manufactured for them at Animal Orthocare, LLC and had a complete medical record were identified for this study.  A client survey was completed via e-mail or telephone to collect further data about the patients, including age, weight, breed, sex, affected limb(s, reason for prosthesis, level of amputation, activities patient could perform with prosthesis in place, prosthetic fit, prosthetic migration (e

  9. [Silicone breast prosthesis and rheumatoid arthritis: a new systemic disease: siliconosis. A case report and a critical review of the literature].

    Iannello, S; Belfiore, F

    1998-04-01

    Today the number of women receiving breast implants of silicone gel, for augmentation or reconstruction of the breast, is increasing. Silicon implants may cause local complications (such as capsular contracture, rupture, closed capsulotomy, gel "bleed", nodular foreign body granulomas in the capsular tissue and lymph nodes) or general symptoms. An adverse immune reaction with signs and symptoms of rheumatoid disorders is also possible, although an increased frequency of true autoimmune systemic connective tissue diseases is controversial. The US Food and Drug Administration advised that these silicone implants should be used only in reconstructive surgery and as part of clinical trials. Silicone is not an inert substance and silicone compounds were found in the blood and liver of women with silicone breast implants. The development of disease related to silicone implants would depend on genetic factors, so that only a very few women are potentially at risk. HLA-DR53 may be a marker of predisposed subjects. Breast-feeding by women with silicone implants should not be recommended for possible autoimmune disorders in the children. We report the case of an adult female patient with silicone breast implantation for bilateral mastectomy (performed 12 months before) and a unique syndrome characterized by low-grade fever, chronic fatigue, arthralgias of the hands, dysphagia, dry eye, increased level of rheumatoid factor and decreased value of complement C3 and C4. No increased erythrocyte sedimentation rate occurred, and no ANA, nDNA, ENA and AAT autoantibodies were evidence. A critical review of literature (source: MEDLINE 1980-1997) was performed and our case seems to be the first one reported in Italy. The internist should become familiar with the immunological disorders related to silicone breast implants, often so marked to require the explantation of the prostheses to improve symptomatology. However, perhaps due to the leak and spreading of silicone, the progression

  10. Balancing auditor choices during the transition from a mandatory to a voluntary joint audit system in Denmark

    Holm, Claus; Thinggaard, Frank

    This paper examines agency explanations for choice of auditor in the context of the transition from a mandatory to a voluntary joint audit system in Denmark. Our findings suggest that companies do use auditor choices as a balancing mechanism against independence threats.More specifically, we find...... more frequent rotation when single auditor are appointed, more equal audit fee share in the year before the voluntary joint audit system took effect and higher propensity to choose non-BigN auditor (absence of dominance) when joint audits are chosen, and lower NAS increases when joint audits...... are involved. We also find that the length of relationship with prime BigN auditors are longer than for non-BigN, thus suggesting potential problem with independence in appearance consistent with the EC green paper issues raised concerning audit firm concentration. However, we do not find differences between...

  11. Joint System Prognostics For Increased Efficiency And Risk Mitigation In Advanced Nuclear Reactor Instrumentation and Control

    Donald D. Dudenhoeffer; Tuan Q. Tran; Ronald L. Boring; Bruce P. Hallbert

    2006-08-01

    The science of prognostics is analogous to a doctor who, based on a set of symptoms and patient tests, assesses a probable cause, the risk to the patient, and a course of action for recovery. While traditional prognostics research has focused on the aspect of hydraulic and mechanical systems and associated failures, this project will take a joint view in focusing not only on the digital I&C aspect of reliability and risk, but also on the risks associated with the human element. Model development will not only include an approximation of the control system physical degradation but also on human performance degradation. Thus the goal of the prognostic system is to evaluate control room operation; to identify and potentially take action when performance degradation reduces plant efficiency, reliability or safety.

  12. POD evaluation for joint angles from inertial and optical motion capturing system

    Shimizu, Kai; Kobayashi, Futoshi; Nakamoto, Hiroyuki; Kojima, Fumio

    2016-01-01

    It has been recognized that advances in preventive maintenance can improve the sustainment of systems, facilities, and infrastructure. Robot technologies have also received attention for maintenance applications. In order to operate delicate tasks, multi-fingered robot hands have been proposed in cases where human capability is deficient. This paper deals with motion capturing systems for controlling the hand/arm robot remotely. Several types of motion capturing systems have been developed so far. However, it is difficult for individual motion capturing systems to measure precise joint angles of a human arm. Therefore, in this paper, we integrate the inertial motion capturing system with the optical motion capturing system to capture a human arm posture. By evaluating the reliability of each motion capturing system, the integration is carried out. The probability of detection (POD) is applied to evaluate and compare the reliability of datasets measured by each motion capturing system. POD is one of the widely used statistical techniques to determine reliability. We apply the â analysis to determine the POD(a) function from the data set. Based on the POD evaluation, two motion capturing systems are integrated. (author)

  13. Optimally Joint Subcarrier Matching and Power Allocation in OFDM Multihop System

    Shuyuan Yang

    2008-04-01

    Full Text Available Orthogonal frequency division multiplexing (OFDM multihop system is a promising way to increase capacity and coverage. In this paper, we propose an optimally joint subcarrier matching and power allocation scheme to further maximize the total channel capacity with the constrained total system power. First, the problem is formulated as a mixed binary integer programming problem, which is prohibitive to find the global optimum in terms of complexity. Second, by making use of the equivalent channel power gain for any matched subcarrier pair, a low complexity scheme is proposed. The optimal subcarrier matching is to match subcarriers by the order of the channel power gains. The optimal power allocation among the matched subcarrier pairs is water-filling. An analytical argument is given to prove that the two steps achieve the optimally joint subcarrier matching and power allocation. The simulation results show that the proposed scheme achieves the largest total channel capacity as compared to the other schemes, where there is no subcarrier matching or no power allocation.

  14. Optimally Joint Subcarrier Matching and Power Allocation in OFDM Multihop System

    Wang Wenyi

    2008-01-01

    Full Text Available Orthogonal frequency division multiplexing (OFDM multihop system is a promising way to increase capacity and coverage. In this paper, we propose an optimally joint subcarrier matching and power allocation scheme to further maximize the total channel capacity with the constrained total system power. First, the problem is formulated as a mixed binary integer programming problem, which is prohibitive to find the global optimum in terms of complexity. Second, by making use of the equivalent channel power gain for any matched subcarrier pair, a low complexity scheme is proposed. The optimal subcarrier matching is to match subcarriers by the order of the channel power gains. The optimal power allocation among the matched subcarrier pairs is water-filling. An analytical argument is given to prove that the two steps achieve the optimally joint subcarrier matching and power allocation. The simulation results show that the proposed scheme achieves the largest total channel capacity as compared to the other schemes, where there is no subcarrier matching or no power allocation.

  15. Does the nervous system use equilibrium-point control to guide single and multiple joint movements?

    Bizzi, E; Hogan, N; Mussa-Ivaldi, F A; Giszter, S

    1992-12-01

    The hypothesis that the central nervous system (CNS) generates movement as a shift of the limb's equilibrium posture has been corroborated experimentally in studies involving single- and multijoint motions. Posture may be controlled through the choice of muscle length-tension curve that set agonist-antagonist torque-angle curves determining an equilibrium position for the limb and the stiffness about the joints. Arm trajectories seem to be generated through a control signal defining a series of equilibrium postures. The equilibrium-point hypothesis drastically simplifies the requisite computations for multijoint movements and mechanical interactions with complex dynamic objects in the environment. Because the neuromuscular system is springlike, the instantaneous difference between the arm's actual position and the equilibrium position specified by the neural activity can generate the requisite torques, avoiding the complex "inverse dynamic" problem of computing the torques at the joints. The hypothesis provides a simple, unified description of posture and movement as well as contact control task performance, in which the limb must exert force stably and do work on objects in the environment. The latter is a surprisingly difficult problem, as robotic experience has shown. The prior evidence for the hypothesis came mainly from psychophysical and behavioral experiments. Our recent work has shown that microstimulation of the frog spinal cord's premotoneural network produces leg movements to various positions in the frog's motor space. The hypothesis can now be investigated in the neurophysiological machinery of the spinal cord.

  16. [The esthetics of lower limb prosthesis].

    Gardrat, Franck

    2015-01-01

    The amputation, which is upper or lower limb, entails important consequences and often traumatic into subject amputee from a physical, psychological, interpersonal and social point of view. It acts on the body image unleashing different psychological disorders and alterations in the social and professional reality. The aesthetic prosthesis can be considered a good support to help the person regain a new body image of themselves, facilitating the process of physical rehabilitation and social integration.

  17. Development and clinical application of a new testicular prosthesis.

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-11-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction.

  18. Designing Bare Base Systems for Logistics Efficiency in the Joint Operational Environment

    Trautmann, Jr, William D

    2007-01-01

    .... In recent conflicts, the lack of joint doctrine or joint bare base architecture has hampered the ability of the services to achieve fully operational forward locations within a satisfactory length of time...

  19. Bio-Inspired Control of an Arm Exoskeleton Joint with Active-Compliant Actuation System

    Michele Folgheraiter

    2009-01-01

    Full Text Available This paper presents the methodology followed on the design of a multi-contact point haptic interface that uses a bio-inspired control approach and a novel actuation system. The combination of these components aims at creating a system that increases the operability of the target, and, at the same time, enables an intuitive and safe tele-operation of any complex robotic system of any given morphology. The novelty lies on the combination of a thoughtful kinematic structure driven by an active-compliant actuation system and a bio-inspired paradigm for its regulation. Due to the proposed actuation approach, the final system will achieve the condition of wearable system. On that final solution, each joint will be able to change its stiffness depending on the task to be executed, and on the anatomical features of each individual. Moreover, the system provides a variety of safety mechanisms at different levels to prevent causing any harm to the operator. In future, the system should allow the complete virtual immersion of the user within the working scenario.

  20. [CLINICAL APPLICATION OF OXFORD MOBILE-BEARING BIPOLAR PROSTHESIS UNICOMPARTMENTAL KNEE ARTHROPLASTY FOR SINGLE COMPARTMENTAL KNEE OSTEOARTHRITIS].

    Wang, Shangzeng; Cheng, Shao; Wang, Yisheng

    2016-01-01

    To evaluate the effectiveness of Oxford mobile-bearing bipolar prosthesis unicompartmental knee arthroplasty (UKA) in the treatment of single compartmental knee osteoarthritis. Between June 2011 and July 2013, 22 cases of single compartmental knee osteoarthritis were treated by Oxford mobile-bearing bipolar prosthesis UKA. Of 22 cases, 8 were male and 14 were female with an average age of 65 years (range, 45-80 years); the left knee was involved in 12 cases, and the right knee in 10 cases, with a mean disease duration of 32.5 months (range, 8-90 months). The mean weight was 55.2 kg (range, 50-65 kg), and the mean body mass index was 20.8 kg/m2 (range, 17-25 kg/m2). Osteoarthritis involved in the single knee medial compartment in all patients. Knee society score (KSS) and range of motion (ROM) were measured to evaluate the knee joint function. Primary healing of incision was obtained in all patients, and there was no complication of infection, bedsore, or deep venous thrombosis. Postoperative follow-up was 2-4 years (mean, 3.2 years). The X-ray films showed good position of prosthesis, no prosthesis dislocation, or periprosthetic infection during follow-up. Knee ROM, KSS function score, and KSS clinical score were significantly improved at 1 week after operation and at last follow-up when compared with preoperative ones (P 0.05). Oxford mobile-bearing bipolar prosthesis UKA is an effective method to treat single compartmental knee osteoarthritis, with the advantages of less trauma, earlier rehabilitation exercise, near physiological state in joint function, and less risk of complications.

  1. HyPro: A Multi-DoF Hybrid-Powered Transradial Robotic Prosthesis

    C. L. Semasinghe

    2018-01-01

    Full Text Available This paper proposes a multi-DoF hybrid-powered transradial robotic prosthesis, named HyPro. The HyPro consists of two prosthetic units: hand and wrist that can achieve five grasping patterns such as power grasp, tip grasp, lateral grasp, hook grasp, and index point. It is an underactuated device with 15 degrees of freedom. A hybrid powering concept is proposed and implemented on hand unit of HyPro where the key focus is on restoration of grasp functions of biological hand. A novel underactuated mechanism is introduced to achieve the required hand preshaping for a given grasping pattern using electric power in the pregrasp stage and body power is used in grasp stage to execute the final grasping action with the selected fingers. Unlike existing hybrid prostheses where each of the joints is separately controlled by either electric or body power, the proposed prosthesis is capable of delivering grasping power in combination. The wrist unit of HyPro is designed and developed to achieve flexion-extension and supination-pronation using electric power. Experiments were carried out to evaluate the functionality and performance of the proposed hybrid-powered robotic prosthesis. The results verified the potential of HyPro to perform intended grasping patterns effectively and efficiently.

  2. Rehabilitation of amputed thumb with a silicone prosthesis

    Asnani, Pooja; Shivalingappa, Chandu Giriyapura; Mishra, Sunil Kumar; Somkuwar, Kirti; Khan, Faisal

    2015-01-01

    Creating prosthesis, having realistic skin surface and seamless visual integration with the surrounding tissues, requires both artistic and technical skill. Anatomical design, thin margins, lifelike fingernails and realistic color/contours are essential for patient satisfaction. Prosthesis is especially useful in case of lost body parts, as reconstructive surgery cannot fully restore aesthetics. This case report describes a simple technique for fabricating silicon finger prosthesis for a pati...

  3. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    Levin, M.F.; Munk, P.L.; Vellet, A.D.; Chin, J.L.

    1994-01-01

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  4. Laser-assisted fixation of a nitinol stapes prosthesis.

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Neglected chaos in international stock markets: Bayesian analysis of the joint return-volatility dynamical system

    Tsionas, Mike G.; Michaelides, Panayotis G.

    2017-09-01

    We use a novel Bayesian inference procedure for the Lyapunov exponent in the dynamical system of returns and their unobserved volatility. In the dynamical system, computation of largest Lyapunov exponent by traditional methods is impossible as the stochastic nature has to be taken explicitly into account due to unobserved volatility. We apply the new techniques to daily stock return data for a group of six countries, namely USA, UK, Switzerland, Netherlands, Germany and France, from 2003 to 2014, by means of Sequential Monte Carlo for Bayesian inference. The evidence points to the direction that there is indeed noisy chaos both before and after the recent financial crisis. However, when a much simpler model is examined where the interaction between returns and volatility is not taken into consideration jointly, the hypothesis of chaotic dynamics does not receive much support by the data ("neglected chaos").

  6. Managing Safety and Operations: The Effect of Joint Management System Practices on Safety and Operational Outcomes.

    Tompa, Emile; Robson, Lynda; Sarnocinska-Hart, Anna; Klassen, Robert; Shevchenko, Anton; Sharma, Sharvani; Hogg-Johnson, Sheilah; Amick, Benjamin C; Johnston, David A; Veltri, Anthony; Pagell, Mark

    2016-03-01

    The aim of this study was to determine whether management system practices directed at both occupational health and safety (OHS) and operations (joint management system [JMS] practices) result in better outcomes in both areas than in alternative practices. Separate regressions were estimated for OHS and operational outcomes using data from a survey along with administrative records on injuries and illnesses. Organizations with JMS practices had better operational and safety outcomes than organizations without these practices. They had similar OHS outcomes as those with operations-weak practices, and in some cases, better outcomes than organizations with safety-weak practices. They had similar operational outcomes as those with safety-weak practices, and better outcomes than those with operations-weak practices. Safety and operations appear complementary in organizations with JMS practices in that there is no penalty for either safety or operational outcomes.

  7. Joint Adaptive Modulation and Combining for Hybrid FSO/RF Systems

    Rakia, Tamer

    2015-11-12

    In this paper, we present and analyze a new transmission scheme for hybrid FSO/RF communication system based on joint adaptive modulation and adaptive combining. Specifically, the data rate on the FSO link is adjusted in discrete manner according to the FSO link\\'s instantaneous received signal-to-noise-ratio (SNR). If the FSO link\\'s quality is too poor to maintain the target bit-error-rate, the system activates the RF link along with the FSO link. When the RF link is activated, simultaneous transmission of the same modulated data takes place on both links, where the received signals from both links are combined using maximal ratio combining scheme. In this case, the data rate of the system is adjusted according to the instantaneous combined SNRs. Novel analytical expression for the cumulative distribution function (CDF) of the received SNR for the proposed adaptive hybrid system is obtained. This CDF expression is used to study the spectral and outage performances of the proposed adaptive hybrid FSO/RF system. Numerical examples are presented to compare the performance of the proposed adaptive hybrid FSO/RF system with that of switch-over hybrid FSO/RF and FSO-only systems employing the same adaptive modulation schemes. © 2015 IEEE.

  8. The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

    Smith, Scott A [Univ. of Maryland Baltimore County (UMBC), Baltimore, MD (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Catalfamo, Simone [Univ. of Stuttgart (Germany); Brake, Matthew R. W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rice Univ., Houston, TX (United States); Schwingshackl, Christoph W. [Imperial College, London (United Kingdom); Reusb, Pascal [Daimler AG, Stuttgart (Germany)

    2017-01-01

    In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

  9. ACTIVITY OF CANONICAL WNT SIGNAL SYSTEM IN HYALINE CARTILAGE ARTICULAR CHONDROCYTES IN PROCESS OF SYNOVIAL JOINT DEVELOPMENT

    A.O. Molotkov

    2009-03-01

    Full Text Available Canonical and non-canonical Wnt systems are essential regulators of chondrogenesis and bone development. However, the roles of these systems in synovial joint development are not well studied. To determine if canonical Wnt system is active in developing articular chondrocytes we used immunohistochemistry for в-galactosidase and doublecortin (cell-type specific marker for articular chondrocytes to double label sections through joint regions of E14.5, E18.5, P10 and adult mice. Here the following results are presented. Canonical Wnt signal system does not work in developing articular chondrocytes at early embryonic stages (E14.5; it is active in the articular chondrocytes at late embryonic stages (E16.5-E18.5 and during postnatal development (P7-P10, but is turned off again in the adult articular chondrocytes. These results suggest that canonical Wnt signaling is being regulated during articular chondrocytes differentiation and joint formation.

  10. Effect of Stiffness of Rolling Joints on the Dynamic Characteristic of Ball Screw Feed Systems in a Milling Machine

    Dazhong Wang

    2015-01-01

    Full Text Available Dynamic characteristic of ball screw feed system in a milling machine is studied numerically in this work. In order to avoid the difficulty in determining the stiffness of rolling joints theoretically, a dynamic modeling method for analyzing the feed system is discussed, and a stiffness calculation method of the rolling joints is proposed based on the Hertz contact theory. Taking a 3-axis computer numerical control (CNC milling machine set ermined as a research object, the stiffness of its fixed joint between the column and the body together with the stiffness parameters of the rolling joints is evaluated according to the Takashi Yoshimura method. Then, a finite element (FE model is established for the machine tool. The correctness of the FE model and the stiffness calculation method of the rolling joints are validated by theoretical and experimental modal analysis results of the machine tool’s workbench. Under the two modeling methods of joints incorporating the stiffness parameters and rigid connection, a theoretical modal analysis is conducted for the CNC milling machine. The natural frequencies and modal shapes reveal that the joints’ dynamic characteristic has an important influence on the dynamic performance of a whole machine tool, especially for the case with natural frequency and higher modes.

  11. An anthropomorphic transhumeral prosthesis socket developed based on an oscillometric pump and controlled by force-sensitive resistor pressure signals.

    Razak, N A Abd; Gholizadeh, H; Hasnan, N; Osman, N A Abu; Fadzil, S S Mohd; Hashim, N A

    2017-02-01

    While considering the importance of the interface between amputees and prosthesis sockets, we study an anthropomorphic prosthesis socket whose size can be dynamically changed according to the requirements of the residual limb. First, we introduce the structure and function of the anthropomorphic prosthesis socket. Second, we study the dynamic model of the prosthesis system and analyze the dynamic characteristics of the prosthesis socket system, the inputs of an oscillometric pump, and the control mechanism of force-sensitive resistor (FSR) pressure signals. Experiments on 10 healthy subjects using the designed system yield an average detection result between 102 and 112 kPa for the FSR pressure sensor and 39 and 41 kPa for the oscillometric pump. Results show the function of the FSR pressure signal in maintaining the contact pressure between the sockets and the residual limb. The potential development of an auto-adjusted socket that uses an oscillometric pump system will provide prosthetic sockets with controllable contact pressure at the residual limb. Moreover, this development is an attractive research area for researchers involved in rehabilitation engineering, prosthetics, and orthotics.

  12. Rehabilitation of a Patient with an Intra Oral Prosthesis and an Extra Oral Orbital Prosthesis Retained with Magnets

    Pattanaik, Seema; Wadkar, Aarti P.

    2011-01-01

    This clinical case report deals with a rehabilitation of a patient with an extensive maxillary and orbital defect using an intra oral prosthesis obturating the maxillary defect and extra oral orbital prosthesis retained with rare-earth magnets for secondary retention; primary retention was derived by snug fit of the prosthesis to underlying and adjacent tissues. The rehabilitation resulted in improved function, esthetics and comfort to the patient thus enabling him to lead a normal life.

  13. Joint Design of Control and Power Efficiency in Wireless Networked Control System

    Yan Wang

    2014-01-01

    Full Text Available This paper presents a joint design method for wireless networked control system (WNCS to balance both the demands of network service and the control performance. Since the problems of power consumption, communication reliability, and system stability exist simultaneously and interdependently in WNCS, most of the achieved results in the wireless network and wired networked control system cannot be used directly. To coordinate the three problems, sampling period is found to be the linking bridge. An adaptive sampling power efficiency algorithm is proposed to manage the power consumption such that it can meet the demands of network life span. The sampling period is designed to update periodically on the constraints of network schedulability and system stability. The convergence of the power efficiency algorithm is further proved. The sampling period is no longer a fixed value, however; thus, increasing the difficulty in modeling and controlling such a complicated time-varying system remains. In this work, a switched control system scheme is applied to model such a WNCS, and the effect of network-induced delay is considered. Switched feedback controllers are introduced to stabilize the WNCS, and some considerations on stability condition and the bounds of the update circle for renewing sampling period are discussed. A numerical example shows the effectiveness of the proposed method.

  14. Aerial Measuring System (AMS)/ Israel Atomic Energy Commission (IAEC) Joint Comparison Study

    Halevy, I.; Dadon, S.; Sheinfeld, M.; Broide, A.; Rofe, S.; Yaar, I.; Wasiolek, P.

    2014-01-01

    In support of the U.S. Department of Energy (DOE) International Emergency Management and Cooperation (IEMC/NA-46) Program, the comparison of the U.S. and Israeli Aerial Measuring Systems (AMS) study was proposed and accepted. The study, organized by the DOE/National Nuclear Security Administration (NNSA) Remote Sensing Laboratory (RSL), involved the DOE/NNSA Aerial Measuring System Project based at the RSL and operated under a contractor agreement by National Security Technologies, LLC (NSTec), and the Israel Atomic Energy Commission (IAEC) Aerial Measuring System. The operational comparison was conducted at RSL-Nellis in Las Vegas, Nevada, during week of June 24–27, 2013. The Israeli system, Air RAM 2000 (figure 1, down), was shipped to RSL-Nellis and mounted together with the DOE Spectral Advanced Radiological Computer System, Model A (SPARCS-A, figure 1 up) on U.S. DOE Bell-412 helicopter for a series of aerial comparison measurements at local test ranges, including the Desert Rock Airport and Area 3 at the Nevada National Security Site (NNSS). A four-person Israeli team from the IAEC, Nuclear Research Center – Negev (NRCN) supported the activity. The main objective of this joint comparison was use the DOE/RSL Bell-412 helicopter aerial platform, perform the comparison study of measuring techniques and radiation acquisition systems utilized for emergency response by IEAC and NNSA AMS

  15. Stress distribution in dental prosthesis under an occlusal combined dynamic loading

    Merdji, A.; Bachir Bouiadjra, B.; Ould Chikh, B.; Mootanah, R.; Aminallah, L.; Serier, B.; Muslih, I.M.

    2012-01-01

    Highlights: ► The mechanical stress reaches the highest in areas of cortical bones. ► The mechanical stress in the cancellous bone reaches greatest in the bottom of the dental implant. ► Implant with low-volume bone might cause increased stress concentration in the cortical bone. -- Abstract: The biomechanical behavior of osseointegrated dental prostheses systems plays an important role in its functional longevity inside the bone. Simulation of these systems requires an accurate modeling of the prosthesis components, the jaw bone, the implant–bone interface, and the response of the system to different types of applied forces. The purpose of this study was to develop a new three-dimensional model of an osseointegrated molar dental prosthesis and to carry out finite element analysis to evaluate stress distributions in the bone and the dental prosthesis compounds under an occlusal combined dynamic load was applied to the top of the occlusale face of the prosthesis crown. The jaw bone model containing cortical bone and cancellous bone was constructed by using computer tomography scan pictures and Computer Aided Design tools. The dental prosthesis compounds were constructed, simulating the commercially available cylindrical implant of 4.8 mm diameter and 10 mm length. Both finite element models were created in Abaqus finite element software. All materials used in the models were considered to be isotropic, homogeneous and linearly elastic. The elastic properties, loads and constraints used in the model were taken from published data. Results of our finite element analyses, indicated that the maximum stresses were located around the mesial neck of the implant, in the marginal bone. Thus, this area should be preserved clinically in order to maintain the bone–implant interface structurally and functionally.

  16. Fracture behavior of reaction layers in W and SiC joint system

    Son, S.J.; Kohyama, A.; Yu, I.K.; Cho, S.

    2007-01-01

    Full text of publication follows: SiC and SiC/SiC composites are considering as attractive structural materials for fusion reactors, because of their excellent physical, chemical and nuclear properties in fusion environments. For the application of these materials to gas-cooled fusion blanket systems, they have to satisfy specific requirements, such as hermeticity and surface features, in addition to baseline thermo-mechanical and irradiation properties. One of the critical issues for a fusion technology is a plasma facing material, which is considered in the connection with joining, heat transfer control and protection from helium gas in high temperature components. Tungsten as a coating material for SiC-based plasma-facing components has excellent advantages, such as a small mismatch in coefficient of thermal expansion, a very low sputtering yield, inherent heat resistance and high thermal conductivity. Therefore, tungsten and its alloys are promising as potential coating materials for divertor and first wall applications. In the present work, by using micron-sized tungsten and nano-SiC powders, W-SiC joints were prepared by simultaneous and sequential hot-pressing process. Various reaction products in the tungsten-SiC system were revealed by microstructural analyses. The interfacial phases and thickness were strongly depended on the temperature and time of hot pressing. The fracture characteristics of the reaction layers determine the robustness of W/SiC systems. Therefore, in this work, fracture behaviors by analyzing the indentation induced cracks in each phase and mechanical properties of W/SiC joints were examined. The most high shear strength was obtained in the joints fabricated at the conditions of 1780 deg. C, 20 MPa, 1 hr holding time. Easy crack extension was confirmed in the region of WC phase. The fracture of 1870 deg. C fabrication samples, which showed comparatively low shear strength, occurred at the wide region of reaction phases (WC+W 5 Si 3 +W

  17. Combining cognitive engineering and information fusion architectures to build effective joint systems

    Sliva, Amy L.; Gorman, Joe; Voshell, Martin; Tittle, James; Bowman, Christopher

    2016-05-01

    The Dual Node Decision Wheels (DNDW) architecture concept was previously described as a novel approach toward integrating analytic and decision-making processes in joint human/automation systems in highly complex sociotechnical settings. In this paper, we extend the DNDW construct with a description of components in this framework, combining structures of the Dual Node Network (DNN) for Information Fusion and Resource Management with extensions on Rasmussen's Decision Ladder (DL) to provide guidance on constructing information systems that better serve decision-making support requirements. The DNN takes a component-centered approach to system design, decomposing each asset in terms of data inputs and outputs according to their roles and interactions in a fusion network. However, to ensure relevancy to and organizational fitment within command and control (C2) processes, principles from cognitive systems engineering emphasize that system design must take a human-centered systems view, integrating information needs and decision making requirements to drive the architecture design and capabilities of network assets. In the current work, we present an approach for structuring and assessing DNDW systems that uses a unique hybrid DNN top-down system design with a human-centered process design, combining DNN node decomposition with artifacts from cognitive analysis (i.e., system abstraction decomposition models, decision ladders) to provide work domain and task-level insights at different levels in an example intelligence, surveillance, and reconnaissance (ISR) system setting. This DNDW structure will ensure not only that the information fusion technologies and processes are structured effectively, but that the resulting information products will align with the requirements of human decision makers and be adaptable to different work settings .

  18. The Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy

    fatemeh sari

    2017-12-01

    Full Text Available Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate the effect of silicone prosthesis on photon dose distribution in breast radiotherapy. Materials and Methods: The experimental dosimetry was performed using theprosthetic breast phantom and the female-equivalent mathematical chest phantom. A Computerized Tomographybased treatment planning was performedusing a phantom and by CorePlan Treatment Planning System (TPS. For measuring the absorbed dose, thermoluminescent dosimeter(TLD chips (GR-207A were used. Multiple irradiations were completed for all the TLD positions, and the dose absorbed by the TLDs was read by a lighttelemetry (LTM reader. Results: Statistical comparisons were performed between the absorbed dosesassessed by the TLDs and the TPS calculations forthe same sites. Our initial resultsdemonstratedanacceptable agreement (P=0.064 between the treatment planning data and the measurements. The mean difference between the TPS and TLD resultswas 1.99%.The obtained findings showed that radiotherapy is compatible withsilicone gel prosthesis. Conclusion: It could be concludedthat the siliconbreast prosthesis has no clinicallysignificant effectondistribution of a 6 MV photon beam for reconstructed breasts.

  19. Dose distribution perturbation due to a Co-Cr-Mo prosthesis

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-01-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  20. A phantom study of dose compensation behind hip prosthesis using portal dosimetry and dynamic MLC

    Nielsen, Martin Skovmos; Carl, Jesper; Nielsen, Jane

    2008-01-01

    Background and purpose: A dose compensation method is presented for patients with hip prosthesis based on Dynamic Multi Leaves Collimator (DMLC) planning. Calculations are done from an exit Portal Dose Image (PDI) from 6 MV Photon beam using an Electronic Portal Imaging Device (EPID) from Varian. Four different hip prostheses are used for this work. Methods: From an exit PDI the fluence needed to yield a uniform dose distribution behind the prosthesis is calculated. To back-project the dose distribution through the phantom, the lateral scatter is removed by deconvolution with a point spread function (PSF) determined for depths from 10 to 40 cm. The dose maximum, D max , is determined from the primary plan which delivers the PDI. A further deconvolution to remove the dose glare effect in the EPID is performed as well. Additionally, this calculated fluence distribution is imported into the Treatment Planning System (TPS) for the final calculation of a DMLC plan. The fluence file contains information such as the relative central axis (CAX) position, grid size and fluence size needed for correct delivery of the DMLC plan. GafChromic EBT films positioned at 10 cm depth are used as verification of uniform dose distributions behind the prostheses. As the prosthesis is positioned at the phantom surface the dose verifications are done 10 cm from the prosthesis. Conclusion: The film measurement with 6 MV photon beam shows uniform doses within 5% for most points, but with hot/cold spots of 10% near the femoral head prostheses

  1. Joint optimisation of spare part inventory, maintenance frequency and repair capacity for k-out-of-N systems

    de Smidt-Destombes, Karin S.; van der Heijden, Matthijs C.; van Harten, Aart

    2009-01-01

    To achieve a high system availability at minimal costs, relevant decisions include the choice of preventive maintenance frequency, spare part inventory levels and spare part repair capacity. We develop heuristics for the joint optimisation of these variables for (a) a single k-out-of-N system under

  2. 75 FR 56548 - Joint Meeting of the Peripheral and Central Nervous System Drugs Advisory Committee and the Drug...

    2010-09-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] Joint Meeting of the Peripheral and Central Nervous System Drugs Advisory Committee and the Drug Safety... and Central Nervous System Drugs Advisory Committee and the Drug Safety and Risk Management Advisory...

  3. Development of a Measuring System Based on LabVIEW for Angular Stiffness of Integrative Flexible Joint

    Liu, C J; Wan, D A

    2006-01-01

    In order to meet the need of development of integrative flexible joint, this paper presents a higher precision measuring system for angular stiffness test of integrative flexible joint. The main parts of the system include PC, precision motorized goniometric stage, precision motorized rotary stage and high accuracy torque sensor. The measuring and control program is developed on the platform of LabVIEW. The measuring system developed has angular resolution at 0.00032 deg. (about 1'') theoretically in determining the angular displacement of the joint round its equatorial axis and torque accuracy at 0.005 mN · m. The developed program, which presents a friendly GUI, can implement the data acquisition and processing, measuring procedure automatically. In comparison with other measuring devices with similar purposes, the measuring device can improve the measuring efficiency and accuracy distinctly while has advantages of simple configuration, low cost and high stability

  4. IRS Guidelines: Joint IAEA/NEA International Reporting System for Operating Experience

    2010-01-01

    The International Reporting System for Operating Experience (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the OECD Nuclear Energy Agency (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants which are operated worldwide. This objective can be achieved by providing timely and detailed information on lessons learned from operating and construction experience at the international level. This information could be related to issues and events that are related to safety. The purpose of these guidelines is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the effectiveness of the system expected by all Member States operating nuclear power plants. As this system is owned by the Member States, the IRS Guidelines have been developed and approved by the IRS National Co-ordinators with the assistance of both Secretariats (IAEA/NEA).

  5. Multi-objective market clearing of joint energy and reserves auctions ensuring power system security

    Aghaei, J.; Shayanfar, H.; Amjady, N.

    2009-01-01

    A model and solution approach to day-ahead market clearing of joint energy and reserves auctions is proposed in this paper. The model represents the clearing system used by ISO in charge of both the market operation and system security. A Multiobjective Mathematical Programming (MMP) formulation is implemented for provision of ancillary services (Automatic Generation Control or AGC, Spinning, Non-spinning and operational reserves) as well as energy in simultaneous auctions by pool-based aggregated market scheme. System security is taken into account in the market clearing procedure as the extra objective functions of the optimization problem. So, in the MMP formulation of the market clearing process, the objective functions (generation cost and security indices) are optimized while meeting AC power flow constraints, system reserve requirements and lost opportunity cost (LOC) considerations. The model is applied to the IEEE 24-bus Reliability Test System (IEEE 24-bus RTS), and simulation studies are carried out to examine the effectiveness of the proposed method

  6. An Approach to Optimum Joint Beamforming Design in a MIMO-OFDM Multiuser System

    Pascual-Iserte Antonio

    2004-01-01

    Full Text Available This paper describes a multiuser scenario with several terminals acceding simultaneously to the same frequency channel. The objective is to design an optimal multiuser system that may be used as a comparative framework when evaluating other suboptimal solutions and to contribute to the already published works on this topic. The present work assumes that a centralized manager knows perfectly all the channel responses between all the terminals. According to this, the transmitters and receivers, using antenna arrays and leading to the so-called multiple-input-multiple-output (MIMO channels, are designed in a joint beamforming approach, attempting to minimize the total transmit power subject to quality of service (QoS constraints. Since this optimization problem is not convex, the use of the simulated annealing (SA technique is proposed to find the optimum solution.

  7. Joint channel/frequency offset estimation and correction for coherent optical FBMC/OQAM system

    Wang, Daobin; Yuan, Lihua; Lei, Jingli; wu, Gang; Li, Suoping; Ding, Runqi; Wang, Dongye

    2017-12-01

    In this paper, we focus on analysis of the preamble-based joint estimation for channel and laser-frequency offset (LFO) in coherent optical filter bank multicarrier systems with offset quadrature amplitude modulation (CO-FBMC/OQAM). In order to reduce the noise impact on the estimation accuracy, we proposed an estimation method based on inter-frame averaging. This method averages the cross-correlation function of real-valued pilots within multiple FBMC frames. The laser-frequency offset is estimated according to the phase of this average. After correcting LFO, the final channel response is also acquired by averaging channel estimation results within multiple frames. The principle of the proposed method is analyzed theoretically, and the preamble structure is thoroughly designed and optimized to suppress the impact of inherent imaginary interference (IMI). The effectiveness of our method is demonstrated numerically using different fiber and LFO values. The obtained results show that the proposed method can improve transmission performance significantly.

  8. Rapidly destructive arthrosis of the hip joint in a young adult with systemic lupus erythematosus.

    Lee, Yongseung; Motomura, Goro; Yamamoto, Takuaki; Nakashima, Yasuharu; Ohishi, Masanobu; Hamai, Satoshi; Iura, Kunio; Iwamoto, Yukihide

    2015-10-01

    A 37-year-old female had been treated with corticosteroids for systemic lupus erythematosus clinically diagnosed at age 10. She suddenly had right hip pain without any antecedent trauma. Four months after the onset of pain, she visited her primary care physician. On magnetic resonance imaging, joint space narrowing at the weight-bearing area was already seen with bone marrow edematous lesions in both the femoral head and acetabulum. She was treated non-operatively; however, her pain continued to worsen in severity. Thirteen months after the onset of pain, she was referred to our hospital. A plain radiograph showed subluxation of the collapsed femoral head accompanied by destruction of the acetabular rim. Because of her severe intractable pain, she underwent total hip arthroplasty 1 month after her first visit. Histological examination of the resected femoral head revealed pseudogranulomatous lesions along with prominent callus formation, suggesting rapid destruction of the femoral head.

  9. Transponder-aided joint calibration and synchronization compensation for distributed radar systems.

    Wang, Wen-Qin

    2015-01-01

    High-precision radiometric calibration and synchronization compensation must be provided for distributed radar system due to separate transmitters and receivers. This paper proposes a transponder-aided joint radiometric calibration, motion compensation and synchronization for distributed radar remote sensing. As the transponder signal can be separated from the normal radar returns, it is used to calibrate the distributed radar for radiometry. Meanwhile, the distributed radar motion compensation and synchronization compensation algorithms are presented by utilizing the transponder signals. This method requires no hardware modifications to both the normal radar transmitter and receiver and no change to the operating pulse repetition frequency (PRF). The distributed radar radiometric calibration and synchronization compensation require only one transponder, but the motion compensation requires six transponders because there are six independent variables in the distributed radar geometry. Furthermore, a maximum likelihood method is used to estimate the transponder signal parameters. The proposed methods are verified by simulation results.

  10. Extended Kalman filtering for joint mitigation of phase and amplitude noise in coherent QAM systems.

    Pakala, Lalitha; Schmauss, Bernhard

    2016-03-21

    We numerically investigate our proposed carrier phase and amplitude noise estimation (CPANE) algorithm using extend Kalman filter (EKF) for joint mitigation of linear and non-linear phase noise as well as amplitude noise on 4, 16 and 64 polarization multiplexed (PM) quadrature amplitude modulation (QAM) 224 Gb/s systems. The results are compared to decision directed (DD) carrier phase estimation (CPE), DD phase locked loop (PLL) and universal CPE (U-CPE) algorithms. Besides eliminating the necessity of phase unwrapping function, EKF-CPANE shows improved performance for both back-to-back (BTB) and transmission scenarios compared to the aforementioned algorithms. We further propose a weighted innovation approach (WIA) of the EKF-CPANE which gives an improvement of 0.3 dB in the Q-factor, compared to the original algorithm.

  11. Joint Polar Satellite System (JPSS) Common Ground System (CGS) Technical Performance Measures of the Block 2 Architecture

    Grant, K. D.; Panas, M.

    2016-12-01

    NOAA and NASA are jointly acquiring the next-generation civilian weather satellite system: the Joint Polar Satellite System (JPSS). JPSS replaced the afternoon orbit component and ground processing of NOAA's old POES system. JPSS satellites carry sensors that collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS). Developed and maintained by Raytheon Intelligence, Information and Services (IIS), the CGS is a globally distributed, multi-mission system serving NOAA, NASA and their national and international partners. The CGS has demonstrated its scalability and flexibility to incorporate multiple missions efficiently and with minimal cost, schedule and risk, while strengthening global partnerships in weather and environmental monitoring. The CGS architecture has been upgraded to Block 2.0 to satisfy several key objectives, including: "operationalizing" the first satellite, Suomi NPP, which originally was a risk reduction mission; leveraging lessons learned in multi-mission support, taking advantage of newer, more reliable and efficient technologies and satisfying constraints due of the continually evolving budgetary environment. To ensure the CGS meets these needs, we have developed 48 Technical Performance Measures (TPMs) across 9 categories: Data Availability, Data Latency, Operational Availability, Margin, Scalability, Situational Awareness, Transition (between environments and sites), WAN Efficiency, and Data Recovery Processing. This paper will provide an overview of the CGS Block 2.0 architecture, with particular focus on the 9 TPM categories listed above. We will describe how we ensure the deployed architecture meets these TPMs to satisfy our multi-mission objectives with the deployment of Block 2.0.

  12. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning

    Zuo, Wenwei; Guo, Chi; Liu, Jingnan; Peng, Xuan; Yang, Min

    2018-01-01

    Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI) exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS)/Global Positioning System (GPS) positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API) of the original standard Global Navigation Satellite System (GNSS) to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to meet the

  13. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning

    Wenwei Zuo

    2018-01-01

    Full Text Available Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS/Global Positioning System (GPS positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API of the original standard Global Navigation Satellite System (GNSS to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to

  14. A Police and Insurance Joint Management System Based on High Precision BDS/GPS Positioning.

    Zuo, Wenwei; Guo, Chi; Liu, Jingnan; Peng, Xuan; Yang, Min

    2018-01-10

    Car ownership in China reached 194 million vehicles at the end of 2016. The traffic congestion index (TCI) exceeds 2.0 during rush hour in some cities. Inefficient processing for minor traffic accidents is considered to be one of the leading causes for road traffic jams. Meanwhile, the process after an accident is quite troublesome. The main reason is that it is almost always impossible to get the complete chain of evidence when the accident happens. Accordingly, a police and insurance joint management system is developed which is based on high precision BeiDou Navigation Satellite System (BDS)/Global Positioning System (GPS) positioning to process traffic accidents. First of all, an intelligent vehicle rearview mirror terminal is developed. The terminal applies a commonly used consumer electronic device with single frequency navigation. Based on the high precision BDS/GPS positioning algorithm, its accuracy can reach sub-meter level in the urban areas. More specifically, a kernel driver is built to realize the high precision positioning algorithm in an Android HAL layer. Thus the third-party application developers can call the general location Application Programming Interface (API) of the original standard Global Navigation Satellite System (GNSS) to get high precision positioning results. Therefore, the terminal can provide lane level positioning service for car users. Next, a remote traffic accident processing platform is built to provide big data analysis and management. According to the big data analysis of information collected by BDS high precision intelligent sense service, vehicle behaviors can be obtained. The platform can also automatically match and screen the data that uploads after an accident to achieve accurate reproduction of the scene. Thus, it helps traffic police and insurance personnel to complete remote responsibility identification and survey for the accident. Thirdly, a rapid processing flow is established in this article to meet the

  15. Pseudo-capsule “coffin effect”: How to prevent penile retraction after implant of three-piece inflatable prosthesis

    Enrico Caraceni

    2014-06-01

    Full Text Available Objective: Following three-component implantation of a penile prosthesis, some patients are dissatisfied with their penile length. This may be due to the procedure by itself or pre-existing risk factors or psychological reasons. We supposed that formation of a restricted pseudo-capsule due to a late prosthesis activation can inhibit later system expansion. We aimed to identify the presence or absence of penile retraction after implant and to prevent it by immediate prosthesis activation after implantation. Material and methods. Forty-six patients operated with three-piece inflatable penile prosthesis (AMS 700 CX o LGX were enrolled. In 27 patients prosthesis was first activated four weeks after surgery (NEA group and in 19 patients prosthesis was activated immediately after surgery (DEA group. Length and girth of the penis was evaluated before (in DEA group and after the surgical procedure. Results. The average post implant dorsal length of the erect penis in group NEA was found 3.28 cm shorter than in group with early activation (DEA. In DEA group there was no lenght difference between pre-operative stretching (14.57 cm and post operative erection (14.98 cm. When early activation was not performed, the clinical result was a smaller penis in erect phase. Conclusion. Reduced lenght of the penis after implantation can be caused by the presence of a pseudo-capsule that limits the elongation of the prosthesis and of the penis (“coffin effect”. Timing of first activation seems to be the key in order to prevent the risk of penile retraction after implantation. Early activation is identified as the best measure to maintain the length of the pre implant erect penis after the prosthetic hydraulic implant.

  16. Investigation of the feasibility of joint production of decentralized wind energy systems for the People's Republic of China

    Johansen, P.; Johnson, J.P.; Lundsager, P.

    1990-01-01

    The Commission of the European Communities and the Zhejiang Provincial Science and Technology Commission have together supported the Decentralized Energy Systems for China Project. The paper presents the approach, methods and results of the wind/diesel part of the project, which aimed at supporting the establishment of a joint venture between a European wind turbine manufacturer and a Chinese industrial partner to produce wind/diesel systems for the local market. A comprehensive integrated approach to the project was chosen, the parts of which are discussed in the paper. The paper provides evidence of the good conditions for local production but also indicates why the joint venture has not been established. (Author)

  17. Empirical Study of Distinct Features and Challenges of Joint Development of Information Systems: The Case of ABC Bank

    MAO Jiye; SONG Wenmo

    2008-01-01

    The internal development and outsourced development of information systems have been studied intensively, but little research has been conducted on the joint development mode. This paper describes the benefits and problems encountered in the joint development of accounting management information systems based on a real case. The case illustrates some distinct advantages, such as full control over the development schedule, the flexibility with resource allocation, and insurance for sustained active participation by the end-users. However, this development mode also involves potential problems, e.g., potential conflicts arising from diverse backgrounds and cultures of the various stakeholders and challenges to manage personnel from outside partners.

  18. Elbow joint stability following experimental osteoligamentous injury and reconstruction

    Deutch, Søren R; Jensen, Steen Lund; Tyrdal, Stein

    2003-01-01

    Elbow joint dislocation was simulated in cadaveric specimens to quantify laxity induced by radial head and coronoid process lesions, either alone or in combination with collateral ligament insufficiency. The effects of lateral ligament reconstruction and radial head prosthesis replacement were also...

  19. Development of a Geospatial Data-Sharing Method for Unmanned Vehicles Based on the Joint Architecture for Unmanned Systems (JAUS)

    2005-08-01

    the Office of the Secretary of Defense chartered the Joint Architecture for Unmanned Ground Systems ( JAUGS ) Working Group to address these concerns...The JAUGS Working Group was tasked with developing an initial standard for interoperable unmanned ground systems. In 2002, the charter of the... JAUGS Working Group was 1 2 modified such that their efforts would extend to all unmanned systems, not only ground systems. The standard was

  20. Validation of a standardized mapping system of the hip joint for radial MRA sequencing

    Klenke, Frank M.; Hoffmann, Daniel B.; Cross, Brian J.; Siebenrock, Klaus A.

    2015-01-01

    Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform. (orig.)

  1. Information basis for developing comprehensive waste management system. US-Japan joint nuclear energy action plan waste management working group phase I report (Joint research)

    Yui, Mikazu; Ishikawa, Hirohisa; Umeki, Hiroyuki; Hioki, Kazumasa; Naito, Morimasa; Makino, Hitoshi; Oda, Chie; Tachi, Yukio; Mitsui, Seiichiro; Shibata, Masahiro; Watanabe, Atsuo; Yoshino, Kyoji; Seo, Toshihiro; Miyamoto, Yoichi; Nutt, Mark; Peters, Mark; Bresee, James; Lesica, Sue; Schwab, Patrick; Gomberg, Steve; Jones, Jay; Halsey, Bill; Marra, John; Vienna, John; Gombert, Drik; McMahon, Kevin; James, Scott; Caporuscio, Florie

    2010-05-01

    The activity of Phase I of the Waste Management Working Group under the United States - Japan Joint Nuclear Energy Action Plan started in 2007. The US-Japan JNEAP is a bilateral collaborative framework to support the global implementation of safe, secure, and sustainable, nuclear fuel cycles (referred to in this document as fuel cycles). The Waste Management Working Group was established by strong interest of both parties, which arise from the recognition that development and optimization of waste management and disposal system(s) are central issues of the present and future nuclear fuel cycles. This report summarizes the activity of the Waste Management Working Group that focused on consolidation of the existing technical basis between the U.S. and Japan and the joint development of a plan for future collaborative activities. Firstly, the political/regulatory frameworks related to nuclear fuel cycles in both countries were reviewed. The various advanced fuel cycle scenarios that have been considered in both countries were then surveyed and summarized. The working group established the working reference scenario for the future cooperative activity that corresponds to a fuel cycle scenario being considered both in Japan and the U.S. This working scenario involves transitioning from a once-through fuel cycle utilizing light water reactors to a one-pass uranium-plutonium fuel recycle in light water reactors to a combination of light water reactors and fast reactors with plutonium, uranium, and minor actinide recycle, ultimately concluding with multiple recycle passes primarily using fast reactors. Considering the scenario, current and future expected waste streams, treatment and inventory were discussed, and the relevant information was summarized. Second, the waste management/disposal system optimization was discussed. Repository system concepts were reviewed, repository design concepts for the various classifications of nuclear waste were summarized, and the factors

  2. Fabrication of custom made ocular prosthesis with three different ...

    Loss of eye has a bad effect on the psychology of the patient. Eye prosthesis is fabricated to regain the patient's confidence by meticulous replacement of the missing eye. Immediate fitting of an anophthalmic socket with an artificial eye may not always be possible, and a delayed prosthesis delivery may result in settling and ...

  3. Treatment of femoral neck fracture by Moore Prosthesis in Cotonou ...

    Treatment of femoral neck fracture by Moore Prosthesis in Cotonou. AHM Akue, M Lawson, S Madougou, R Zannou, J Padonou. Abstract. Keywords: Benin; hip; Moore prosthesis; results. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  4. A direct bonded fixed partial dental prosthesis: A clinical report

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced.

  5. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  6. Analysis of the mechanical behavior of the Nijdam voice prosthesis

    Verkerke, GJ; deVries, MP; Schutte, HK; vandenHoogen, FJA; Rakhorst, G

    1997-01-01

    The valveless Nijdam prosthesis is a new voice prosthesis for laryngectomized patients using tracheoesophageal speech. An ''umbrella-like hat'' covers the esophageal side of the tracheoesophageal fistula and is deformed during speech by air pressure. To decrease pressure loss during speech, a good

  7. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  8. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis; Utilite de la tomographie par emission de positons (TEP) dans l'etude des protheses osteo-articulaires

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L. [Centro PET Complutense, Madrid (Spain)

    2004-12-15

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ({sup 18}F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  9. Patient satisfaction with maxillofacial prosthesis. Literature review.

    Goiato, Marcelo Coelho; Pesqueira, Aldiéris Alves; Ramos da Silva, Cristina; Gennari Filho, Humberto; Micheline Dos Santos, Daniela

    2009-02-01

    Obturators and facial prostheses are important not only in rehabilitation and aesthetics, but also in patient re-socialisation. The level of reintegration is directly related to the degree of satisfaction with rehabilitation. So, the maxillofacial prosthetics must provide patient satisfaction during treatment. This study aimed to search information in database and conduct a literature review on patient satisfaction with maxillofacial prosthesis. The problems experienced by these patients may decrease when specialists keep the patient on regular inspection. Rehabilitation through alloplasty or prosthetic restoration provides satisfactory conditions in aesthetics and well-being and reinstates individuals in familial and social environment.

  10. Metabolic Pattern of Asymptomatic Hip-Prosthesis by 18F-FDG-Positron-Emission-Tomography

    Beslic, Nermina; Heber, Daniel; Walter Lipp, Rainer; Sonneck-Koenne, Charlotte; Knoll, Peter; Mirzaei, Siroos

    2015-01-01

    Joint replacement is a procedure with a major impact on the quality of life of patients with joint degenerative disease or traumatic injuries. However, some patients develop symptoms after the intervention caused by mechanical loosening or infection. Metabolic imaging by 18F-FDG-PET investigated in these patients isoften hampered by low specificity for diagnosis of possible septic vs. mechanical loosening. The reason for this shortcoming is to our opinion the unawareness of physiological remodeling processes that could be seen in asymptomatic patients. In order to overcome this drawback, we aimed to find out the physiological metabolic functional pattern in asymptomatic patients with implanted hip prosthesis Twelve patients (6 males, 6 females); mean age 73 ± 7 (range 58 - 91) years were prospectively enrolled in the study. The patients were admitted to our department for oncological referral with implanted hip prostheses. All patients explained no symptoms with regard to their implanted prosthesis. The attenuation corrected images were used for analysis. Fourteen hip prostheses in 12 patients were visually analyzed. Seven out of 14 prostheses among 12 patients showed focal periprosthetic enhanced metabolism, two of which showed two sites of enhanced uptake; whereas, the remaining five prostheses showed singular hypermetabolic areas within the periprosthetic site. The remaining seven prostheses in the other five patients showed no periprosthetic-enhanced uptake. Of the asymptomatic patients investigated, 58% showed focal enhanced periprosthetic glucose metabolism. This finding should be taken into consideration as a more probable unspecific metabolic pattern for correct interpretation of 18F-FDG-PET studies in patients with suspected septic loosening of the hip prosthesis

  11. Penile Corporeal Reconstruction during Difficult Placement of a Penile Prosthesis

    Viet Q. Tran

    2008-01-01

    Full Text Available For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64, all patients had a prosthesis that was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10. There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.

  12. Amputation and prosthesis implantation shape body and peripersonal space representations.

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-10-03

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb.

  13. Elastic Elements in a Wrist Prosthesis for Drumming Reduce Muscular Effort, but Increase Imprecision and Perceived Stress

    Georg Stillfried

    2018-03-01

    Full Text Available Recently, progress has been made in the development of mechanical joints with variable intrinsic stiffness, opening up the search for application areas of such variable-stiffness joints. By varying the stiffness of its joints, the resonant frequency of a system can be tuned to perform cyclical tasks most energy-efficiently, making the variable-stiffness joint a candidate element for an advanced prosthetic device specifically designed for the cyclical task of drumming. A prerequisite for a successful variable-stiffness drumming prosthesis is the ability of human drummers to profitably employ different stiffness levels for playing different beats. In this pilot study, 29 able-bodied subjects (20 drumming novices and 9 experts wear a cuff on the forearm, to which a drumstick is connected using changeable adapters, consisting of several leaf springs with different stiffness and one maximally stiff connection element. The subjects are asked to play simple regular drum beats at different frequencies, one of which is the resonant frequency of the adapter-drumstick system. The subject's performance of each drumming task is rated in terms of accuracy and precision, and the effort is measured using questionnaires for the perceived stress as well as electromyography (EMG for the muscular activity. The experiments show that using springs instead of the stiff connection leads to lower muscular activity, indicating that humans are able to use the energy-storing capabilities of the springs, or that muscular activity is reduced due to the lower mass of the springs. However, the perceived stress is increased and the novices' performance lowered, possibly due to a higher cerebral load for controlling the elastic system. The hypothesis that “matching the resonant frequency of the spring-drumstick system to the desired frequency leads to better performance and lower effort” is not confirmed. Possible explanations are discussed. In conclusion, a series

  14. Elastic Elements in a Wrist Prosthesis for Drumming Reduce Muscular Effort, but Increase Imprecision and Perceived Stress

    Stillfried, Georg; Stepper, Johannes; Neppl, Hannah; Vogel, Jörn; Höppner, Hannes

    2018-01-01

    Recently, progress has been made in the development of mechanical joints with variable intrinsic stiffness, opening up the search for application areas of such variable-stiffness joints. By varying the stiffness of its joints, the resonant frequency of a system can be tuned to perform cyclical tasks most energy-efficiently, making the variable-stiffness joint a candidate element for an advanced prosthetic device specifically designed for the cyclical task of drumming. A prerequisite for a successful variable-stiffness drumming prosthesis is the ability of human drummers to profitably employ different stiffness levels for playing different beats. In this pilot study, 29 able-bodied subjects (20 drumming novices and 9 experts) wear a cuff on the forearm, to which a drumstick is connected using changeable adapters, consisting of several leaf springs with different stiffness and one maximally stiff connection element. The subjects are asked to play simple regular drum beats at different frequencies, one of which is the resonant frequency of the adapter-drumstick system. The subject's performance of each drumming task is rated in terms of accuracy and precision, and the effort is measured using questionnaires for the perceived stress as well as electromyography (EMG) for the muscular activity. The experiments show that using springs instead of the stiff connection leads to lower muscular activity, indicating that humans are able to use the energy-storing capabilities of the springs, or that muscular activity is reduced due to the lower mass of the springs. However, the perceived stress is increased and the novices' performance lowered, possibly due to a higher cerebral load for controlling the elastic system. The hypothesis that “matching the resonant frequency of the spring-drumstick system to the desired frequency leads to better performance and lower effort” is not confirmed. Possible explanations are discussed. In conclusion, a series-elastic element appears to

  15. A web-based system for neural network based classification in temporomandibular joint osteoarthritis.

    de Dumast, Priscille; Mirabel, Clément; Cevidanes, Lucia; Ruellas, Antonio; Yatabe, Marilia; Ioshida, Marcos; Ribera, Nina Tubau; Michoud, Loic; Gomes, Liliane; Huang, Chao; Zhu, Hongtu; Muniz, Luciana; Shoukri, Brandon; Paniagua, Beatriz; Styner, Martin; Pieper, Steve; Budin, Francois; Vimort, Jean-Baptiste; Pascal, Laura; Prieto, Juan Carlos

    2018-07-01

    The purpose of this study is to describe the methodological innovations of a web-based system for storage, integration and computation of biomedical data, using a training imaging dataset to remotely compute a deep neural network classifier of temporomandibular joint osteoarthritis (TMJOA). This study imaging dataset consisted of three-dimensional (3D) surface meshes of mandibular condyles constructed from cone beam computed tomography (CBCT) scans. The training dataset consisted of 259 condyles, 105 from control subjects and 154 from patients with diagnosis of TMJ OA. For the image analysis classification, 34 right and left condyles from 17 patients (39.9 ± 11.7 years), who experienced signs and symptoms of the disease for less than 5 years, were included as the testing dataset. For the integrative statistical model of clinical, biological and imaging markers, the sample consisted of the same 17 test OA subjects and 17 age and sex matched control subjects (39.4 ± 15.4 years), who did not show any sign or symptom of OA. For these 34 subjects, a standardized clinical questionnaire, blood and saliva samples were also collected. The technological methodologies in this study include a deep neural network classifier of 3D condylar morphology (ShapeVariationAnalyzer, SVA), and a flexible web-based system for data storage, computation and integration (DSCI) of high dimensional imaging, clinical, and biological data. The DSCI system trained and tested the neural network, indicating 5 stages of structural degenerative changes in condylar morphology in the TMJ with 91% close agreement between the clinician consensus and the SVA classifier. The DSCI remotely ran with a novel application of a statistical analysis, the Multivariate Functional Shape Data Analysis, that computed high dimensional correlations between shape 3D coordinates, clinical pain levels and levels of biological markers, and then graphically displayed the computation results. The findings of this

  16. Joint verification project on environmentally friendly coal utilization systems. Joint verification project on the water-saving coal preparation system; Kankyo chowagata sekitan riyo system kyodo jissho jigyo. Shosuigata sentan system kyodo jissho jigyo

    NONE

    1995-09-01

    In this verification project, clean technology which should be spread in China was verified and the base structure for its spread was prepared for the purpose of controlling emissions of environmental pollutants associated with the coal utilization in China and of contributing to secure energy acquisition of Japan. As joint verification projects, a general rehabilitation type coal preparation system was installed in the Wangfenggang coal preparation plant, and a central control coal preparation system was installed in the Qingtan coal preparation plant. In the former, a system is verified in which optimum operation, water-saving, high quality, and heightening of efficiency can be obtained by introducing two computing systems for operation control and quality control, various measuring instruments, and analyzers to coal preparation plants where analog operation is conducted helped by Russia and Porland and have problems about quality control. In the latter, a central control system achieving water saving is verified by introducing rapid ash meters, scales, desitometers and computers to coal preparation plants having zigzag or heavy-fluid cyclon and connecting various kinds of information through network. For fiscal 1994, investigation and study were conducted. 51 figs., 9 tabs.

  17. Learning from demonstration: Teaching a myoelectric prosthesis with an intact limb via reinforcement learning.

    Vasan, Gautham; Pilarski, Patrick M

    2017-07-01

    Prosthetic arms should restore and extend the capabilities of someone with an amputation. They should move naturally and be able to perform elegant, coordinated movements that approximate those of a biological arm. Despite these objectives, the control of modern-day prostheses is often nonintuitive and taxing. Existing devices and control approaches do not yet give users the ability to effect highly synergistic movements during their daily-life control of a prosthetic device. As a step towards improving the control of prosthetic arms and hands, we introduce an intuitive approach to training a prosthetic control system that helps a user achieve hard-to-engineer control behaviours. Specifically, we present an actor-critic reinforcement learning method that for the first time promises to allow someone with an amputation to use their non-amputated arm to teach their prosthetic arm how to move through a wide range of coordinated motions and grasp patterns. We evaluate our method during the myoelectric control of a multi-joint robot arm by non-amputee users, and demonstrate that by using our approach a user can train their arm to perform simultaneous gestures and movements in all three degrees of freedom in the robot's hand and wrist based only on information sampled from the robot and the user's above-elbow myoelectric signals. Our results indicate that this learning-from-demonstration paradigm may be well suited to use by both patients and clinicians with minimal technical knowledge, as it allows a user to personalize the control of his or her prosthesis without having to know the underlying mechanics of the prosthetic limb. These preliminary results also suggest that our approach may extend in a straightforward way to next-generation prostheses with precise finger and wrist control, such that these devices may someday allow users to perform fluid and intuitive movements like playing the piano, catching a ball, and comfortably shaking hands.

  18. JOINT-INDUSTRY PARTNERSHIP TO DEVELOP A HOLLOW SPHERE DUAL-GRADIENT DRILLING SYSTEM

    William C. Maurer; Colin Ruan; Greg Deskins

    2003-05-01

    Maurer Technology Inc. (MTI) formed a joint-industry partnership to fund the development of a hollow sphere dual-gradient drilling (DGD) system. Phase I consisted of collecting, compiling, analyzing, and distributing information and data regarding a new DGD system for use by the oil and gas industry. Near the end of Phase I, DOE provided funding to the project that was used to conduct a series of critical follow-on tests investigating sphere separation in weighted waterbase and oilbase muds. Drilling costs in deep water are high because seawater pressure on the ocean floor creates a situation where many strings of casing are required due to the relatively close spacing between fracture and pore pressure curves. Approximately $100 million have been spent during the past five years on DGD systems that place pumps on the seafloor to reduce these drilling problems by reducing the annulus fluid pressure at the bottom of the riser. BP estimates that a DGD system can save $9 million per well in the Thunderhorse Field and Conoco estimates it can save $5 to $15 million per well in its deepwater operations. Unfortunately, previous DGD development projects have been unsuccessful due to the high costs ($20 to $50 million) and reliability problems with seafloor pump systems. MTI has been developing a simple DGD system concept that would pump hollow glass spheres into the bottom of the riser to reduce density of the mud in the riser. This eliminates the requirement for seafloor pumps and replaces them with low cost mud pumps, shale shakers, and other oilfield equipment that can be operated on the rig by conventional crews. A $1.8 million Phase I joint-industry project funded by five service companies and three operators showed that hollow spheres could be pumped well, but difficulties were encountered in separating the spheres from a polymer mud supplied by Halliburton due to the high viscosity of this mud at the low shear rates encountered on oilfield shale shaker screens. As a

  19. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    Efiaty A. Soepardi

    2005-03-01

    Full Text Available A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during a period between January 1997 and December 2003. Neck-chest X-ray and esophagoscopy were performed in all patients to identify the existence of the dental prosthesis as a diagnostic and treatment procedure. The length of time for removing the dental prosthesis was recorded and stated as a less difficult esophagoscopy when it takes time less than 60 minutes and as a difficult  esophagoscopy takes 60 minutes or longer. Some risk difficulties factors were statistically analyzed. There were 53 patients of ingested dental prosthesis in esophagus. Only 51 cases were analyzed According to the length of time for removing the dental prosthesis by esophagoscopy, 22 patients were recorded as less difficult cases and 29 patients as difficult cases. Two cases among the cases needed cervicotomy after unsuccessful esophagoscopy removal. The difficulties to diagnose an impacted dental prosthesis in the esophagus caused by unreliable clinical history, unclear signs and symptoms, unable to be detected by X-ray and was not found during esophagoscopy. The difficulties in treating due to mucosal laceration, edema, bleeding, failure of the first extraction and conformity with the size and shape, the wire outside the dental prosthesis and the length of time stayed in the esophagus. (Med J Indones 2005; 14: 33-6Keywords: ingested dental prosthesis, radioluscent foreign body, length of time of esophagoscopy

  20. Selection of contact bearing couple materials for hip prosthesis using finite element analysis under static conditions

    Arirajan, K. A.; Chockalingam, K.; Vignesh, C.

    2018-04-01

    Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.

  1. System-Level Coupled Modeling of Piezoelectric Vibration Energy Harvesting Systems by Joint Finite Element and Circuit Analysis

    Congcong Cheng

    2016-01-01

    Full Text Available A practical piezoelectric vibration energy harvesting (PVEH system is usually composed of two coupled parts: a harvesting structure and an interface circuit. Thus, it is much necessary to build system-level coupled models for analyzing PVEH systems, so that the whole PVEH system can be optimized to obtain a high overall efficiency. In this paper, two classes of coupled models are proposed by joint finite element and circuit analysis. The first one is to integrate the equivalent circuit model of the harvesting structure with the interface circuit and the second one is to integrate the equivalent electrical impedance of the interface circuit into the finite element model of the harvesting structure. Then equivalent circuit model parameters of the harvesting structure are estimated by finite element analysis and the equivalent electrical impedance of the interface circuit is derived by circuit analysis. In the end, simulations are done to validate and compare the proposed two classes of system-level coupled models. The results demonstrate that harvested powers from the two classes of coupled models approximate to theoretic values. Thus, the proposed coupled models can be used for system-level optimizations in engineering applications.

  2. Joint density-functional theory and its application to systems in solution

    Petrosyan, Sahak A.

    The physics of solvation, the interaction of water with solutes, plays a central role in chemistry and biochemistry, and it is essential for the very existence of life. Despite the central importance of water and the advent of the quantum theory early in the twentieth century, the link between the fundamental laws of physics and the observable properties of water remain poorly understood to this day. The central goal of this thesis is to develop a new formalism and framework to make the study of systems (solutes or surfaces) in contact with liquid water as practical and accurate as standard electronic structure calculations without the need for explicit averaging over large ensembles of configurations of water molecules. The thesis introduces a new form of density functional theory for the ab initio description of electronic systems in contact with a molecular liquid environment. This theory rigorously joins an electron density-functional for the electrons of a solute with a classical density-functional theory for the liquid into a single variational principle for the free energy of the combined system. Using the new form of density-functional theory for the ab initio description of electronic systems in contact with a molecular liquid environment, the thesis then presents the first detailed study of the impact of a solvent on the surface chemistry of Cr2O3, the passivating layer of stainless steel alloys. In comparison to a vacuum, we predict that the presence of water has little impact on the adsorption of chloride ions to the oxygen-terminated surface but has a dramatic effect on the binding of hydrogen to that surface. A key ingredient of a successful joint density functional theory is a good approximate functional for describing the solvent. We explore how the simplest examples of the best known class of approximate forms for the classical density functional fail when applied directly to water. The thesis then presents a computationally efficient density

  3. Early warning monitoring system of modular expansion joints based on dynamic behaviour

    Peelen, W.H.A.; Vervuurt, A.H.J.M.; Zuada Coelho, B.E.; Leendertz, H.

    2012-01-01

    One of the existing modular expansion joints of the Martinus Nijhoff Bridge in the Netherlands was monitored with the purpose of extending its service life for on year until replacement in 2011. Based on an analysis of the failure mechanisms of this (type of) joint, strain gauges were used as

  4. IMU-Based Joint Angle Measurement for Gait Analysis

    Thomas Seel

    2014-04-01

    Full Text Available This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1 joint axis and position identification; and (2 flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°.

  5. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    Butler, W; Merrick, G; Kurko, B; Bittner, N

    2014-01-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible

  6. A Comprehensive Evaluation of Joint Range and Angle Estimation in Indoor Ultrawideband Location Systems

    Gentile Camillo

    2008-01-01

    Full Text Available Abstract Fine time resolution enables ultrawideband (UWB ranging systems to extract the first multipath arrival corresponding to the range between a transmitter and receiver, even when attenuated in strength compared to later arrivals. Bearing systems alone lack any notion of time and in general select the strongest arrival which is rarely the first one in nonline-of-sight conditions. Complementing UWB ranging systems with bearing capabilities allows indexing the arrivals as a function of both time and angle in order to isolate the first, providing precision range and angle. However, that precision degrades with the increasing presence of walls and other objects which distort the properties of the first arrival. In order to gauge the physical limits of the joint UWB system, we design and assemble a spatial-temporal channel sounder using a vector network analyzer coupled to a virtual antenna array, and conduct 200 experiments to measure the time- and angle-of-flight. The experiments are carried out in both line-of-sight and nonline-of-sight conditions up to an unprecedented 45 meters throughout four separate buildings with dominant wall material varying from sheet rock to steel. In addition, we report performance for varying bandwidth and center frequency of the system. We find that operating at a bandwidth of 4 GHz suffices in resolving multipath in most buildings and in excess shows virtually no improvement. While the range error decreases at lower center frequencies, the higher frequencies offer better angular resolution and so smaller angle error.

  7. Joint force protection advanced security system (JFPASS) "the future of force protection: integrate and automate"

    Lama, Carlos E.; Fagan, Joe E.

    2009-09-01

    The United States Department of Defense (DoD) defines 'force protection' as "preventive measures taken to mitigate hostile actions against DoD personnel (to include family members), resources, facilities, and critical information." Advanced technologies enable significant improvements in automating and distributing situation awareness, optimizing operator time, and improving sustainability, which enhance protection and lower costs. The JFPASS Joint Capability Technology Demonstration (JCTD) demonstrates a force protection environment that combines physical security and Chemical, Biological, Radiological, Nuclear, and Explosive (CBRNE) defense through the application of integrated command and control and data fusion. The JFPASS JCTD provides a layered approach to force protection by integrating traditional sensors used in physical security, such as video cameras, battlefield surveillance radars, unmanned and unattended ground sensors. The optimization of human participation and automation of processes is achieved by employment of unmanned ground vehicles, along with remotely operated lethal and less-than-lethal weapon systems. These capabilities are integrated via a tailorable, user-defined common operational picture display through a data fusion engine operating in the background. The combined systems automate the screening of alarms, manage the information displays, and provide assessment and response measures. The data fusion engine links disparate sensors and systems, and applies tailored logic to focus the assessment of events. It enables timely responses by providing the user with automated and semi-automated decision support tools. The JFPASS JCTD uses standard communication/data exchange protocols, which allow the system to incorporate future sensor technologies or communication networks, while maintaining the ability to communicate with legacy or existing systems.

  8. Classification of EMG signals using artificial neural networks for virtual hand prosthesis control.

    Mattioli, Fernando E R; Lamounier, Edgard A; Cardoso, Alexandre; Soares, Alcimar B; Andrade, Adriano O

    2011-01-01

    Computer-based training systems have been widely studied in the field of human rehabilitation. In health applications, Virtual Reality presents itself as an appropriate tool to simulate training environments without exposing the patients to risks. In particular, virtual prosthetic devices have been used to reduce the great mental effort needed by patients fitted with myoelectric prosthesis, during the training stage. In this paper, the application of Virtual Reality in a hand prosthesis training system is presented. To achieve this, the possibility of exploring Neural Networks in a real-time classification system is discussed. The classification technique used in this work resulted in a 95% success rate when discriminating 4 different hand movements.

  9. Analysis and compensation for the joint effects of HPA nonlinearity, I/Q imbalance and crosstalk in MIMO beamforming systems

    Qi, Jian; Aissa, Sonia

    2011-01-01

    In this paper, we investigate the joint effects of high-power amplifier (HPA) nonlinearity, in-phase/quadrature-phase (I/Q) imbalance and crosstalk, on the performance of multiple-input multiple-output (MIMO) transmit beamforming (TB) systems

  10. Report from the Third Annual Symposium of the RIKEN-Max Planck Joint Research Center for Systems Chemical Biology.

    Brunschweiger, Andreas

    2014-08-15

    The third Annual Symposium of the RIKEN-Max Planck Joint Research Center for Systems Chemical Biology was held at Ringberg castle, May 21-24, 2014. At this meeting 45 scientists from Japan and Germany presented the latest results from their research spanning a broad range of topics in chemical biology and glycobiology.

  11. Timing Metrics of Joint Timing and Carrier-Frequency Offset Estimation Algorithms for TDD-based OFDM systems

    Hoeksema, F.W.; Srinivasan, R.; Schiphorst, Roelof; Slump, Cornelis H.

    2004-01-01

    In joint timing and carrier offset estimation algorithms for Time Division Duplexing (TDD) OFDM systems, different timing metrics are proposed to determine the beginning of a burst or symbol. In this contribution we investigated the different timing metrics in order to establish their impact on the

  12. Aerial Measuring System (AMS)/Israel Atomic Energy Commission (IAEC) Joint Comparison Study Report

    Wasiolek, P.; Halevy, I.

    2013-01-01

    Under the 13th Bilateral Meeting to Combat Nuclear Terrorism conducted on January 8-9, 2013, the committee approved the development of a cost-effective proposal to conduct a Comparison Study of the Aerial Measuring System (AMS) of the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA) and Israel Atomic Energy Commission (IAEC). The study was to be held at the Remote Sensing Laboratory (RSL), Nellis Air Force Base, Las Vegas, Nevada, with measurements at the Nevada National Security Site (NNSS). The goal of the AMS and the IAEC joint survey was to compare the responses of the two agencies' aerial radiation detection systems to varied radioactive surface contamination levels and isotopic composition experienced at the NNSS, and the differing data processing techniques utilized by the respective teams. Considering that for the comparison both teams were using custom designed and built systems, the main focus of the short campaign was to investigate the impact of the detector size and data analysis techniques used by both teams. The AMS system, SPectral Advanced Radiological Computer System, Model A (SPARCS-A), designed and built by RSL, incorporates four different size sodium iodide (NaI) crystals: 1'' x 1'', 2'' x 4'' x 4'', 2'' x 4'' x16'', and an ''up-looking'' 2'' x 4'' x 4''. The Israel AMS System, Air RAM 2000, was designed by the IAEC Nuclear Research Center - Negev (NRCN) and built commercially by ROTEM Industries (Israel) and incorporates two 2'' diameter x 2'' long NaI crystals. The operational comparison was conducted at RSL-Nellis in Las Vegas, Nevada, during week of June 24-27, 2013. The Israeli system, Air RAM 2000, was shipped to RSL-Nellis and mounted together with the DOE SPARCS on a DOE Bell-412 helicopter for a series of aerial comparison measurements at local test

  13. An Adaptive Joint Sparsity Recovery for Compressive Sensing Based EEG System

    Hamza Djelouat

    2017-01-01

    Full Text Available The last decade has witnessed tremendous efforts to shape the Internet of things (IoT platforms to be well suited for healthcare applications. These platforms are comprised of a network of wireless sensors to monitor several physical and physiological quantities. For instance, long-term monitoring of brain activities using wearable electroencephalogram (EEG sensors is widely exploited in the clinical diagnosis of epileptic seizures and sleeping disorders. However, the deployment of such platforms is challenged by the high power consumption and system complexity. Energy efficiency can be achieved by exploring efficient compression techniques such as compressive sensing (CS. CS is an emerging theory that enables a compressed acquisition using well-designed sensing matrices. Moreover, system complexity can be optimized by using hardware friendly structured sensing matrices. This paper quantifies the performance of a CS-based multichannel EEG monitoring. In addition, the paper exploits the joint sparsity of multichannel EEG using subspace pursuit (SP algorithm as well as a designed sparsifying basis in order to improve the reconstruction quality. Furthermore, the paper proposes a modification to the SP algorithm based on an adaptive selection approach to further improve the performance in terms of reconstruction quality, execution time, and the robustness of the recovery process.

  14. Performance Evaluation of New Joint EDF-RM Scheduling Algorithm for Real Time Distributed System

    Rashmi Sharma

    2014-01-01

    Full Text Available In Real Time System, the achievement of deadline is the main target of every scheduling algorithm. Earliest Deadline First (EDF, Rate Monotonic (RM, and least Laxity First are some renowned algorithms that work well in their own context. As we know, there is a very common problem Domino's effect in EDF that is generated due to overloading condition (EDF is not working well in overloading situation. Similarly, performance of RM is degraded in underloading condition. We can say that both algorithms are complements of each other. Deadline missing in both events happens because of their utilization bounding strategy. Therefore, in this paper we are proposing a new scheduling algorithm that carries through the drawback of both existing algorithms. Joint EDF-RM scheduling algorithm is implemented in global scheduler that permits task migration mechanism in between processors in the system. In order to check the improved behavior of proposed algorithm we perform simulation. Results are achieved and evaluated in terms of Success Ratio (SR, Average CPU Utilization (ECU, Failure Ratio (FR, and Maximum Tardiness parameters. In the end, the results are compared with the existing (EDF, RM, and D_R_EDF algorithms. It has been shown that the proposed algorithm performs better during overloading condition as well in underloading condition.

  15. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Reusing Joint Polar Satellite System (jpss) Ground System Components to Process AURA Ozone Monitoring Instrument (omi) Science Products

    Moses, J. F.; Jain, P.; Johnson, J.; Doiron, J. A.

    2017-12-01

    New Earth observation instruments are planned to enable advancements in Earth science research over the next decade. Diversity of Earth observing instruments and their observing platforms will continue to increase as new instrument technologies emerge and are deployed as part of National programs such as Joint Polar Satellite System (JPSS), Geostationary Operational Environmental Satellite system (GOES), Landsat as well as the potential for many CubeSat and aircraft missions. The practical use and value of these observational data often extends well beyond their original purpose. The practicing community needs intuitive and standardized tools to enable quick unfettered development of tailored products for specific applications and decision support systems. However, the associated data processing system can take years to develop and requires inherent knowledge and the ability to integrate increasingly diverse data types from multiple sources. This paper describes the adaptation of a large-scale data processing system built for supporting JPSS algorithm calibration and validation (Cal/Val) node to a simplified science data system for rapid application. The new configurable data system reuses scalable JAVA technologies built for the JPSS Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) system to run within a laptop environment and support product generation and data processing of AURA Ozone Monitoring Instrument (OMI) science products. Of particular interest are the root requirements necessary for integrating experimental algorithms and Hierarchical Data Format (HDF) data access libraries into a science data production system. This study demonstrates the ability to reuse existing Ground System technologies to support future missions with minimal changes.

  17. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly

  18. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  19. Prediction of Tensile Strength of Friction Stir Weld Joints with Adaptive Neuro-Fuzzy Inference System (ANFIS) and Neural Network

    Dewan, Mohammad W.; Huggett, Daniel J.; Liao, T. Warren; Wahab, Muhammad A.; Okeil, Ayman M.

    2015-01-01

    Friction-stir-welding (FSW) is a solid-state joining process where joint properties are dependent on welding process parameters. In the current study three critical process parameters including spindle speed (??), plunge force (????), and welding speed (??) are considered key factors in the determination of ultimate tensile strength (UTS) of welded aluminum alloy joints. A total of 73 weld schedules were welded and tensile properties were subsequently obtained experimentally. It is observed that all three process parameters have direct influence on UTS of the welded joints. Utilizing experimental data, an optimized adaptive neuro-fuzzy inference system (ANFIS) model has been developed to predict UTS of FSW joints. A total of 1200 models were developed by varying the number of membership functions (MFs), type of MFs, and combination of four input variables (??,??,????,??????) utilizing a MATLAB platform. Note EFI denotes an empirical force index derived from the three process parameters. For comparison, optimized artificial neural network (ANN) models were also developed to predict UTS from FSW process parameters. By comparing ANFIS and ANN predicted results, it was found that optimized ANFIS models provide better results than ANN. This newly developed best ANFIS model could be utilized for prediction of UTS of FSW joints.

  20. Aerial Measuring System (AMS)/Israel Atomic Energy Commission (IAEC) Joint Comparison Study Report

    Wasiolek, P. [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Halevy, I. [Israel Atomic Energy Commission (IAEC), Yavne (Israel)

    2013-12-23

    Under the 13th Bilateral Meeting to Combat Nuclear Terrorism conducted on January 8–9, 2013, the committee approved the development of a cost-effective proposal to conduct a Comparison Study of the Aerial Measuring System (AMS) of the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA) and Israel Atomic Energy Commission (IAEC). The study was to be held at the Remote Sensing Laboratory (RSL), Nellis Air Force Base, Las Vegas, Nevada, with measurements at the Nevada National Security Site (NNSS). The goal of the AMS and the IAEC joint survey was to compare the responses of the two agencies’ aerial radiation detection systems to varied radioactive surface contamination levels and isotopic composition experienced at the NNSS, and the differing data processing techniques utilized by the respective teams. Considering that for the comparison both teams were using custom designed and built systems, the main focus of the short campaign was to investigate the impact of the detector size and data analysis techniques used by both teams. The AMS system, SPectral Advanced Radiological Computer System, Model A (SPARCS-A), designed and built by RSL, incorporates four different size sodium iodide (NaI) crystals: 1" × 1", 2" × 4" × 4", 2" × 4" ×16", and an “up-looking” 2" × 4" × 4". The Israel AMS System, Air RAM 2000, was designed by the IAEC Nuclear Research Center – Negev (NRCN) and built commercially by ROTEM Industries (Israel) and incorporates two 2" diameter × 2" long NaI crystals. The operational comparison was conducted at RSL-Nellis in Las Vegas, Nevada, during week of June 24–27, 2013. The Israeli system, Air RAM 2000, was shipped to RSL-Nellis and mounted together with the DOE SPARCS on a DOE Bell-412 helicopter for a series of aerial comparison measurements at local test ranges, including the Desert Rock Airport and Area 3 at the NNSS. A 4-person Israeli team from the IAEC NRCN supported the activity together with 11

  1. Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint.

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-12-01

    Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.

  2. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  3. Operation and reliability of a pneumatic hydrogen pellet injection system on the Joint European Torus

    Combs, S.K.; Jernigan, T.C.; Baylor, L.R.; Milora, S.L.; Foust, C.R.; Kupschus, P.; Gadeberg, M.; Bailey, W.; Commission of the European Communities, Abingdon

    1989-01-01

    A pneumatic-based, hydrogen isotope pellet injector that was developed at the Oak Ridge National Laboratory for the plasma fueling application on the Joint European Torus (JET) was described at the last Symposium on Fusion Engineering (1987). The injector was installed on JET during 1987 and has since been used in plasma fueling experiments. The injector consists of three independent machine-gun-like mechanisms (nominal pellet sizes of 2.7, 4.0, and 6.0 mm in diameter), and it features repetitive operation (1-5 Hz) for quasi-steady-state conditions (>10 s). An extensive set of injector diagnostics permits evaluation of parameters for each pellet shot, including speed, mass, and integrity. Pellet speeds can be varied but typically range from 1.0 to 1.5 km/s. Over 5000 pellets have been fired with the equipment at JET, including about 2000 pellets shot for plasma fueling experiments. In recent experiments, the system performance has been outstanding, including excellent reproducibility in pellet speed and mass and a reliability of >98% in delivery of pellets to the plasma. 7 refs., 5 figs

  4. Power adaptation for joint switched diversity and adaptive modulation schemes in spectrum sharing systems

    Bouida, Zied

    2012-09-01

    Under the scenario of an underlay cognitive radio network, we propose in this paper an adaptive scheme using transmit power adaptation, switched transmit diversity, and adaptive modulation in order to improve the performance of existing switching efficient schemes (SES) and bandwidth efficient schemes (BES). Taking advantage of the channel reciprocity principle, we assume that the channel state information (CSI) of the interference link is available to the secondary transmitter. This information is then used by the secondary transmitter to adapt its transmit power, modulation constellation size, and used transmit branch. The goal of this joint adaptation is to minimize the average number of switched branches and the average system delay given the fading channel conditions, the required error rate performance, and a peak interference constraint to the primary receiver. We analyze the proposed scheme in terms of the average number of branch switching, average delay, and we provide a closed-form expression of the average bit error rate (BER). We demonstrate through numerical examples that the proposed scheme provides a compromise between the SES and the BES schemes. © 2012 IEEE.

  5. Power adaptation for joint switched diversity and adaptive modulation schemes in spectrum sharing systems

    Bouida, Zied; Tourki, Kamel; Ghrayeb, Ali A.; Qaraqe, Khalid A.; Alouini, Mohamed-Slim

    2012-01-01

    Under the scenario of an underlay cognitive radio network, we propose in this paper an adaptive scheme using transmit power adaptation, switched transmit diversity, and adaptive modulation in order to improve the performance of existing switching efficient schemes (SES) and bandwidth efficient schemes (BES). Taking advantage of the channel reciprocity principle, we assume that the channel state information (CSI) of the interference link is available to the secondary transmitter. This information is then used by the secondary transmitter to adapt its transmit power, modulation constellation size, and used transmit branch. The goal of this joint adaptation is to minimize the average number of switched branches and the average system delay given the fading channel conditions, the required error rate performance, and a peak interference constraint to the primary receiver. We analyze the proposed scheme in terms of the average number of branch switching, average delay, and we provide a closed-form expression of the average bit error rate (BER). We demonstrate through numerical examples that the proposed scheme provides a compromise between the SES and the BES schemes. © 2012 IEEE.

  6. Geo-engineering, Governance, and Social-Ecological Systems: Critical Issues and Joint Research Needs

    Victor Galaz

    2012-03-01

    Full Text Available The debate about the possibilities to engineer the Earth's climate has changed drastically in the last years. Suggestions of large-scale technological interventions to combat climate change that a decade ago would have been discarded as science fiction are slowly moving into the center of international climate change discussions, research, and politics. In this article, I elaborate three joint key challenges to geo-engineering research from a resilience perspective, with a special emphasis on governance issues. First, I discuss the need to understand geo-engineering proposals from a "planetary boundaries" perspective. Second, I elaborate why the notion of Earth stewardship and geo-engineering are not necessarily in conflict, but instead could be viewed as complementary approaches. Last, I discuss the critical need to explore an institutional setting that is strong enough to weed out geo-engineering proposals that carry considerable ecological risk, but still allow for novelty, fail-safe experimentation, and continuous learning. These issues are critical for our understanding of how to effectively govern global environmental risks, complex systems, and emerging technologies in the Anthropocene.

  7. Crack Resistance of Welded Joints of Pipe Steels of Strength Class K60 of Different Alloying Systems

    Tabatchikova, T. I.; Tereshchenko, N. A.; Yakovleva, I. L.; Makovetskii, A. N.; Shander, S. V.

    2018-03-01

    The crack resistance of welded joints of pipe steels of strength class K60 and different alloying systems is studied. The parameter of the crack tip opening displacement (CTOD) is shown to be dependent on the size of the austenite grains and on the morphology of bainite in the superheated region of the heat-affected zone of the weld. The crack resistance is shown to be controllable due to optimization of the alloying system.

  8. Frequent complications and severe bone loss associated with the repiphysis expandable distal femoral prosthesis.

    Cipriano, Cara A; Gruzinova, Irina S; Frank, Rachel M; Gitelis, Steven; Virkus, Walter W

    2015-03-01

    The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit

  9. Grinding assembly, grinding apparatus, weld joint defect repair system, and methods

    Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.

    2005-09-27

    A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.

  10. A framework for joint management of regional water-energy systems

    Pereira-Cardenal, S.J.

    2013-09-15

    Water and energy systems are closely linked. Energy is needed in most stages of water usage, while water is needed to extract and process energy resources and generate electric power. However, policy goals associated with providing adequate water and energy supplies are often in opposition, causing conflicts over these two resources. This problem will be aggravated by population growth, rising living standards and climate change, highlighting the importance of developing integrated assessment and solutions. In this context, this study focused on the interaction between water and electric energy (or power) systems, with the goal of identifying a method that could be used to assess the broader spatio-temporal interactions between water and energy systems. The proposed method is to include water users and power producers into a joint optimization problem that minimizes the cost of power production and maximizes the benefits of water allocation. This approach turns the multiobjective problem of water and power system management into a single objective one: net costs minimization. The economic value of water is calculated as a function of the state of the system, and this value is used to determine optimal allocations for each time step of the planning horizon. The physical linkages between the two systems are described as constraints in the optimization problem, and the problem is solved using stochastic dynamic programming or stochastic dual dynamic programming. The method was implemented on the Iberian Peninsula to assess some of the interactions between the water and power system. The impact of climate change on the current Iberian power system was assessed. It was found that expected precipitation reductions will reduce runoff, decrease hydropower production, and increase irrigation water demand; whereas expected temperature increases will modify seasonal power demand patterns. The proposed approach was also used to determine hydropower benefits in a coupled water

  11. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  12. A modified technique for retention of orbital prosthesis

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  13. Problems encountered during the development and implantation of the Baylor-Rice orthotopic cardiac prosthesis

    Ross, J.N. Jr.; Akers, W.W.; O'Bannon, W.; Spargo, W.J.; Serrato, M.A.; Fuqua, J.M. Jr.; Ruark, B.S.; Wieting, D.W.; Kennedy, J.H.; DeBakey, M.E.

    1972-01-01

    The problems associated with the development of an artificial heart are enumerated. In a series of 24 calf implantations, several of the animals stood unassisted and reacted normally, but all eventually died with deteriorating circulatory and pulmonary systems. The problems caused by pump size and geometry represented the most important deterrents to long-term survival. A new prosthesis, though not yet tested in animals, is believed to minimize these problems. (auth)

  14. A Comparison Of Joint Ordering Rule And Other Inventory Order Systems

    ÖZGEN, Hüseyin

    2013-01-01

    The typical manuracturing corporation has about fourty or fifty percent of its total assets invested in inventory items Because of this reason inventory control is considered to be one of the most important problems that deserves a special attention of top management There are several diferent inventory control techniques that can be used in inventory management The joint ordering rule discused here is some of the most powerful techniques This paper presents a comparison of joint order...

  15. Interfacial reaction of Sn-based solder joint in the package system

    Gu, Huandi

    In this thesis, I report a study on the effect of the solder size on intermetallic layer formation by comparing the morphology change and growth rate of two different size solder joint aged at a same temperature for different aging time. The layer thickness and microstructure were analyzed using scanning electron microscopy (SEM). Photoshop was used to measure the thickness of intermetallic compound. Two different size of solder joints with composition of Sn-Ag-Cu (305) were used.

  16. Electronic System for Data Record and Automatic Diagnosis Assessment in the Temporomandibular Joint Disorders

    Hippmann, R.; Nagy, Miroslav; Dostálová, T.; Zvárová, Jana; Seydlová, M.

    2011-01-01

    Roč. 7, č. 1 (2011), s. 11-16 ISSN 1801-5603 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : temporomandibular joint * temporomandibular joint disorders * DentCross * electronic health record * AAOP classification Subject RIV: IN - Informatics, Computer Science http://www.ejbi.eu/images/2011-1/Hippmann_en.pdf

  17. Estimating net joint torques from kinesiological data using optimal linear system theory.

    Runge, C F; Zajac, F E; Allum, J H; Risher, D W; Bryson, A E; Honegger, F

    1995-12-01

    Net joint torques (NJT) are frequently computed to provide insights into the motor control of dynamic biomechanical systems. An inverse dynamics approach is almost always used, whereby the NJT are computed from 1) kinematic measurements (e.g., position of the segments), 2) kinetic measurements (e.g., ground reaction forces) that are, in effect, constraints defining unmeasured kinematic quantities based on a dynamic segmental model, and 3) numerical differentiation of the measured kinematics to estimate velocities and accelerations that are, in effect, additional constraints. Due to errors in the measurements, the segmental model, and the differentiation process, estimated NJT rarely produce the observed movement in a forward simulation when the dynamics of the segmental system are inherently unstable (e.g., human walking). Forward dynamic simulations are, however, essential to studies of muscle coordination. We have developed an alternative approach, using the linear quadratic follower (LQF) algorithm, which computes the NJT such that a stable simulation of the observed movement is produced and the measurements are replicated as well as possible. The LQF algorithm does not employ constraints depending on explicit differentiation of the kinematic data, but rather employs those depending on specification of a cost function, based on quantitative assumptions about data confidence. We illustrate the usefulness of the LQF approach by using it to estimate NJT exerted by standing humans perturbed by support-surface movements. We show that unless the number of kinematic and force variables recorded is sufficiently high, the confidence that can be placed in the estimates of the NJT, obtained by any method (e.g., LQF, or the inverse dynamics approach), may be unsatisfactorily low.

  18. Multi-rate sensor fusion-based adaptive discrete finite-time synergetic control for flexible-joint mechanical systems

    Xue Guang-Yue; Ren Xue-Mei; Xia Yuan-Qing

    2013-01-01

    This paper proposes an adaptive discrete finite-time synergetic control (ADFTSC) scheme based on a multi-rate sensor fusion estimator for flexible-joint mechanical systems in the presence of unmeasured states and dynamic uncertainties. Multi-rate sensors are employed to observe the system states which cannot be directly obtained by encoders due to the existence of joint flexibilities. By using an extended Kalman filter (EKF), the finite-time synergetic controller is designed based on a sensor fusion estimator which estimates states and parameters of the mechanical system with multi-rate measurements. The proposed controller can guarantee the finite-time convergence of tracking errors by the theoretical derivation. Simulation and experimental studies are included to validate the effectiveness of the proposed approach. (general)

  19. TEJAS - TELEROBOTICS/EVA JOINT ANALYSIS SYSTEM VERSION 1.0

    Drews, M. L.

    1994-01-01

    The primary objective of space telerobotics as a research discipline is the augmentation and/or support of extravehicular activity (EVA) with telerobotic activity; this allows increased emplacement of on-orbit assets while providing for their "in situ" management. Development of the requisite telerobot work system requires a well-understood correspondence between EVA and telerobotics that to date has been only partially established. The Telerobotics/EVA Joint Analysis Systems (TEJAS) hypermedia information system uses object-oriented programming to bridge the gap between crew-EVA and telerobotics activities. TEJAS Version 1.0 contains twenty HyperCard stacks that use a visual, customizable interface of icon buttons, pop-up menus, and relational commands to store, link, and standardize related information about the primitives, technologies, tasks, assumptions, and open issues involved in space telerobot or crew EVA tasks. These stacks are meant to be interactive and can be used with any database system running on a Macintosh, including spreadsheets, relational databases, word-processed documents, and hypermedia utilities. The software provides a means for managing volumes of data and for communicating complex ideas, relationships, and processes inherent to task planning. The stack system contains 3MB of data and utilities to aid referencing, discussion, communication, and analysis within the EVA and telerobotics communities. The six baseline analysis stacks (EVATasks, EVAAssume, EVAIssues, TeleTasks, TeleAssume, and TeleIssues) work interactively to manage and relate basic information which you enter about the crew-EVA and telerobot tasks you wish to analyze in depth. Analysis stacks draw on information in the Reference stacks as part of a rapid point-and-click utility for building scripts of specific task primitives or for any EVA or telerobotics task. Any or all of these stacks can be completely incorporated within other hypermedia applications, or they can be

  20. DESIGN AND STUDY OF DRIVE SWIVEL JOINTS FOR HYDRAULIC MANIPULATION SYSTEMS OF MOBILE TRANSPORT-TECHNOLOGICAL MACHINES

    Lagerev A.V.

    2018-03-01

    Full Text Available The paper presents the design and principle of operation of a new type of articulated connection of adjacent links of manipulation systems of mobile transport and technological machines – the drive swivel joints to provide a rotary rela-tive movement of the links. Their design allows to combine the function of ensuring the continuity of the kinematic chain and the function of providing rotary movement adjacent units and without the use of additional external devices. The design of the device is protected by a patent of the Russian Federation. Drive swivel joints are an alternative to tra-ditional designs of articulated joints with external power hydraulic drives. Developed a mathematical optimization model. The model is based on the minimization of the mass of the drive swivel joints when you complete the necessary design, installation, operating and strength constraints. Based on this mathematical model the proposed method of com-puter-aided design of the drive swivel joints, which is implemented in a computer program. A study was conducted of the influence of the main technical characteristics and magnitude of the operational load at the optimal weight and the optimal constructive dimensions of the drive swivel joints. It is shown that at equal freight-altitude characteristics of mobile crane-manipulator the drive swivel joint allows you to exclude a number of operational shortcomings of the tra-ditional swivel: 1 development over time of the additional dynamic load of metal due to the increased clearances in connection; 2 lowering the volume of the working area of the crane due to the presence of external power of hydraulic drives; 3 the appearance of cracks due to fatigue failure of the elements of the attachment point of the hydraulic drives to the links of manipulation system. It is possible that the transfer of the hydraulic system for lower operating pressure, which increases the efficiency of the crane and the efficiency of the

  1. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  2. Online Phase Detection Using Wearable Sensors for Walking with a Robotic Prosthesis

    Maja Goršič

    2014-02-01

    Full Text Available This paper presents a gait phase detection algorithm for providing feedback in walking with a robotic prosthesis. The algorithm utilizes the output signals of a wearable wireless sensory system incorporating sensorized shoe insoles and inertial measurement units attached to body segments. The principle of detecting transitions between gait phases is based on heuristic threshold rules, dividing a steady-state walking stride into four phases. For the evaluation of the algorithm, experiments with three amputees, walking with the robotic prosthesis and wearable sensors, were performed. Results show a high rate of successful detection for all four phases (the average success rate across all subjects >90%. A comparison of the proposed method to an off-line trained algorithm using hidden Markov models reveals a similar performance achieved without the need for learning dataset acquisition and previous model training.

  3. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature

    Ernesto Suaste-Gómez

    2016-03-01

    Full Text Available An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa and temperature (2 °C to 90 °C. The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing. More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  4. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature.

    Suaste-Gómez, Ernesto; Rodríguez-Roldán, Grissel; Reyes-Cruz, Héctor; Terán-Jiménez, Omar

    2016-03-04

    An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF) for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa) and temperature (2 °C to 90 °C). The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing). More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  5. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    Humayun, M

    2001-01-01

    An electronic retinal prosthesis is under development to treat retinitis pigmentosa and age-related macular degeneration, two presently incurable diseases of the outer retina that afflict millions world-wide...

  6. 21 CFR 878.3750 - External prosthesis adhesive.

    2010-04-01

    ... used to fasten to the body an external aesthetic restoration prosthesis, such as an artificial nose. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  7. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    Humayun, M

    2001-01-01

    .... Previous studies have established the feasibility of the retinal prosthesis. Short-term tests in blind humans have shown that degenerated retina will respond to light in a way that is consistent with form vision...

  8. Optimal Power Allocation Strategy in a Joint Bistatic Radar and Communication System Based on Low Probability of Intercept.

    Shi, Chenguang; Wang, Fei; Salous, Sana; Zhou, Jianjiang

    2017-11-25

    In this paper, we investigate a low probability of intercept (LPI)-based optimal power allocation strategy for a joint bistatic radar and communication system, which is composed of a dedicated transmitter, a radar receiver, and a communication receiver. The joint system is capable of fulfilling the requirements of both radar and communications simultaneously. First, assuming that the signal-to-noise ratio (SNR) corresponding to the target surveillance path is much weaker than that corresponding to the line of sight path at radar receiver, the analytically closed-form expression for the probability of false alarm is calculated, whereas the closed-form expression for the probability of detection is not analytically tractable and is approximated due to the fact that the received signals are not zero-mean Gaussian under target presence hypothesis. Then, an LPI-based optimal power allocation strategy is presented to minimize the total transmission power for information signal and radar waveform, which is constrained by a specified information rate for the communication receiver and the desired probabilities of detection and false alarm for the radar receiver. The well-known bisection search method is employed to solve the resulting constrained optimization problem. Finally, numerical simulations are provided to reveal the effects of several system parameters on the power allocation results. It is also demonstrated that the LPI performance of the joint bistatic radar and communication system can be markedly improved by utilizing the proposed scheme.

  9. [Bone and joint decade--"mile step" in diagnostics and treatment of movement system diseases?].

    Brongel, Leszek; Lorkowski, Jacek; Hładki, Waldemar; Trybus, Marek

    2006-01-01

    Musculoskeletal disorders affect hundreds of millions of people across the world and are the most common causes of severe long-term pain and physical disability. The impact from such disorders on the individual and on society let to propose by WHO for the Decade of the Bone and Joint from 2000 to 2010. The goal of the Decade is to improve the health-related quality of life for people with musculoskeletal disorders throughout the world and this could be achieved by raising awareness of the growing burden of bone and joint diseases on society, promoting prevention and treatment and advancing understanding of musculoskeletal disorders through research. The main fields of interest during the Decade are joint diseases, spinal disorders and low back pain, osteoporosis and severe trauma of the extremities. In our Department we study problems concerning on traumatology of old patients, multitrauma injury, biomechanics in spinal disorders, in degenerative joint disease and foot diseases. Apart from contemporary imaging methods like US or CT we use pedobarographic diagnostics and fotogrammetric examination. In this study we present strategic goals and the summary of our ongoing projects in our Department related to the goals of the Bone and Joint Decade.

  10. Rehabilitation of single finger amputation with customized silicone prosthesis

    Yadav, Niharika; Chand, Pooran; Jurel, Sunit Kumar

    2016-01-01

    Finger amputations are common in accidents at home, work, and play. Apart from trauma, congenital disease and deformity also leads to finger amputation. This results in loss of function, loss of sensation as well as loss of body image. Finger prosthesis offers psychological support and social acceptance in such cases. This clinical report describes a method to fabricate ring retained silicone finger prosthesis in a patient with partial finger loss.

  11. Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ Implant Arthroplasty

    Amir Reza Kachooei

    2014-09-01

    Full Text Available Background:  Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna.  The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthroplasty using the Aptis (Scheker prosthesis. Methods: We identified 13 patients with 14 prosthesis during the past 10 years. Patients underwent DRUJ arthroplasty due to persistent symptoms of instability, chronic pain, and stiffness. Records and follow-up visits were reviewed to find the final post-operative symptoms, pain, range of motion, and grip strength with a mean follow-up of 12 months (range: 2-25 months. Also, patients were contacted prospectively by phone in order to  minister the disabilities of the armshoulder and hand (DASH, patient rated wrist evaluation (PRWE, and visual analogue scale (VAS, and to interview regarding satisfaction and progress in daily activities. Eleven patients out of 13 could be reached with a median followup time of 60 months (range: 2 to 102 months.  Results: No patient required removal of the prosthesis. Only two patients underwent secondary surgeries in which both required debridement of the screw tip over the radius. The median DASH score, PRWE score, VAS, and satisfaction were 1.3, 2.5, 0, and 10, respectively. The mean range of flexion, extension, supination, and pronation was 62, 54, 51, and 64, respectively. Conclusions: Distal radioulnar joint injuries are disabling and patients usually undergo one or more salvage surgeries prior to receiving an arthroplasty. The Scheker prosthesis has shown satisfactory results with 100% survival rate in all reports. The constrained design of this prosthesis gives enough stability to prevent painful subluxation.

  12. Influence of Angiotensin-Aldosterone System on Ultrasound of Joints in Patients with Rheumatoid Arthritis

    O.B. Komarova

    2014-02-01

    Full Text Available In patients with rheumatoid arthritis and high level of angiotensin II in the blood at ultrasound of joints there are often being detected effusion in the joint cavity, hypervascularization of synovium with 2–3 points and tenosynovitis characterizing inflammatory exudative processes. In patients with high level of aldosterone, hyperplasia of synovium, presence of pannus and bone and cartilage erosions, indicating proliferative-destructive processes, were predominated. Identified correlations show that with increasing levels of angiotensin II in the blood increases the intensity of the vascularization of the synovial membrane, joint effusion, and an increase in the concentration of aldosterone in the blood affects the synovial thickness indicators, the presence of pannus and bone erosions amount.

  13. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  14. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  16. A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke.

    Rong, Wei; Li, Waiming; Pang, Mankit; Hu, Junyan; Wei, Xijun; Yang, Bibo; Wai, Honwah; Zheng, Xiaoxiang; Hu, Xiaoling

    2017-04-26

    It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper limb physical training. The system could assist the elbow, wrist and fingers to conduct arm reaching out, hand opening/grasping and arm withdrawing by tracking an indicative moving cursor on the screen of a computer, with the support from the joint motors and electrical stimulations on target muscles, under the voluntary intention control by electromyography (EMG). Subjects with chronic stroke (n = 11) were recruited for the investigation on the assistive capability of the NMES-robot and the evaluation of the rehabilitation effectiveness through a 20-session device assisted upper limb training. In the evaluation, the movement accuracy measured by the root mean squared error (RMSE) during the tracking was significantly improved with the support from both the robot and NMES, in comparison with those without the assistance from the system (P joint and inter-joint muscular co-contractions measured by EMG were significantly released when the NMES was applied to the agonist muscles in the different phases of the limb motion (P < 0.05). After the physical training, significant improvements (P < 0.05) were captured by the clinical scores, i.e., Modified Ashworth Score (MAS, the elbow and the wrist), Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT), and Wolf Motor Function Test (WMFT). The EMG-driven NMES-robotic system could improve the muscular coordination at the elbow, wrist and fingers. ClinicalTrials.gov. NCT02117089 ; date of registration: April 10, 2014.

  17. [Operative treatment of sacroiliac joint fracture and dislocation in Tile C pelvic fracture with Colorado 2 system].

    Liu, Shuping; Zhou, Qing; Liu, Yuehong; Chen, Xi; Zhou, Yu; Zhang, Desheng; Fang, Zhi; Xu, Wei

    2011-12-01

    To explore the effectiveness of Colorado 2 system in the stability reconstruction of sacroiliac joint fracture and dislocation in Tile C pelvic fracture. Between February 2009 and January 2011, 8 cases of Tile C pelvic fracture were treated with Colorado 2 system. There were 3 males and 5 females with an average age of 34.4 years (range, 22-52 years). Fractures were caused by traffic accident in 3 cases, by falling from height in 3 cases, and by crash of heavy object in 2 cases. According to Tile classification, 5 cases were classified as C1-2, 2 cases as C1-3, and 1 case as C2. The time between injury and operation was 5-10 days (mean, 7 days). After skeletal traction reduction, Colorado 2 system was used to fix sacroiliac joint, and reconstruction plate or external fixation was selectively adopted. The postoperative X-ray films showed that the reduction of vertical and rotatory dislocation was satisfactory, posterior pelvic ring achieved effective stability. All the incisions healed by first intention, and no blood vessel or nerve injury occurred. Eight patients were followed up 6-24 months (mean, 12 months). No loosening or breakage of internal fixation was observed and no re-dislocation of sacroiliac joint occurred. The bone healing time was 6-12 months (mean, 9 months). According to Majeed's functional criterion, the results were excellent in 5 cases, good in 2 cases, and fair in 1 case at last follow-up. Colorado 2 system could provide immediate stability of pelvic posterior ring and good maintenance of reduction effect, which is an effective method in the therapy of sacroiliac joint fracture and dislocation in Tile C pelvic fracture.

  18. IAIMS and JCAHO: implications for hospital librarians. Integrated Academic Information Management Systems. Joint Commission on Accreditation of Healthcare Organizations.

    Doyle, J D

    1999-01-01

    The roles of hospital librarians have evolved from keeping print materials to serving as a focal point for information services and structures within the hospital. Concepts that emerged from the Integrated Academic Information Management Systems (IAIMS) as described in the Matheson Report and the 1994 Joint Commission on Accreditation of Healthcare Organizations (JCAHO) standards have combined to propel hospital libraries into many new roles and functions. This paper will review the relations...

  19. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess ...

  20. A novel joint-processing adaptive nonlinear equalizer using a modular recurrent neural network for chaotic communication systems.

    Zhao, Haiquan; Zeng, Xiangping; Zhang, Jiashu; Liu, Yangguang; Wang, Xiaomin; Li, Tianrui

    2011-01-01

    To eliminate nonlinear channel distortion in chaotic communication systems, a novel joint-processing adaptive nonlinear equalizer based on a pipelined recurrent neural network (JPRNN) is proposed, using a modified real-time recurrent learning (RTRL) algorithm. Furthermore, an adaptive amplitude RTRL algorithm is adopted to overcome the deteriorating effect introduced by the nesting process. Computer simulations illustrate that the proposed equalizer outperforms the pipelined recurrent neural network (PRNN) and recurrent neural network (RNN) equalizers. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Estimation of soil salinity in a drip irrigation system by using joint inversion of multicoil electromagnetic induction measurements

    Jadoon, Khan Zaib

    2015-05-12

    Low frequency electromagnetic induction (EMI) is becoming a useful tool for soil characterization due to its fast measurement capability and sensitivity to soil moisture and salinity. In this research, a new EMI system (the CMD mini-Explorer) is used for subsurface characterization of soil salinity in a drip irrigation system via a joint inversion approach of multiconfiguration EMI measurements. EMI measurements were conducted across a farm where Acacia trees are irrigated with brackish water. In situ measurements of vertical bulk electrical conductivity (σb) were recorded in different pits along one of the transects to calibrate the EMI measurements and to compare with the modeled electrical conductivity (σ) obtained by the joint inversion of multiconfiguration EMI measurements. Estimates of σ were then converted into the universal standard of soil salinity measurement (i.e., electrical conductivity of a saturated soil paste extract – ECe). Soil apparent electrical conductivity (ECa) was repeatedly measured with the CMD mini-Explorer to investigate the temperature stability of the new system at a fixed location, where the ambient air temperature increased from 26°C to 46°C. Results indicate that the new EMI system is very stable in high temperature environments, especially above 40°C, where most other approaches give unstable measurements. In addition, the distribution pattern of soil salinity is well estimated quantitatively by the joint inversion of multicomponent EMI measurements. The approach of joint inversion of EMI measurements allows for the quantitative mapping of the soil salinity distribution pattern and can be utilized for the management of soil salinity.

  2. The Influence of Structure of Joint-Stock Property on the Efficiency of Corporate Management System of Domestic Enterprises

    Trokhymchuk Viktoriia V.

    2017-03-01

    Full Text Available The article is aimed at exploring and analyzing the structure of joint-stock property of Ukrainian enterprises, as well as evaluating its impact on efficiency of the system of corporate management. By studying the results of the privatization of public enterprises and dynamics of the number of companies in recent years, a tendency towards reduction of their total number has been identified. It has been determined that the structure of joint-stock property of domestic enterprises is characterized by a high degree of its concentration. An analysis of the corporate management system of enterprises comparing with the best international practices has displayed a fairly low level of the corporate management efficiency of domestic companies. It has been determined that in these circumstances, consolidation of property in Ukraine became the tool for protecting enterprises from hostile takeover. Measures to eliminate factors, impeding the formation of effective ownership structure of joint-stock property and the related corporate management system, have been proposed. Prospects for further researches will be monitoring changes in the quality of corporate management and property structure of domestic enterprises, as well as studying the factors that cause them.

  3. Streamlining On-Demand Access to Joint Polar Satellite System (JPSS) Data Products for Weather Forecasting

    Evans, J. D.; Tislin, D.

    2017-12-01

    Observations from the Joint Polar Satellite System (JPSS) support National Weather Service (NWS) forecasters, whose Advanced Weather Interactive Processing System (AWIPS) Data Delivery (DD) will access JPSS data products on demand from the National Environmental Satellite, Data, and Information Service (NESDIS) Product Distribution and Access (PDA) service. Based on the Open Geospatial Consortium (OGC) Web Coverage Service, this on-demand service promises broad interoperability and frugal use of data networks by serving only the data that a user needs. But the volume, velocity, and variety of JPSS data products impose several challenges to such a service. It must be efficient to handle large volumes of complex, frequently updated data, and to fulfill many concurrent requests. It must offer flexible data handling and delivery, to work with a diverse and changing collection of data, and to tailor its outputs into products that users need, with minimal coordination between provider and user communities. It must support 24x7 operation, with no pauses in incoming data or user demand; and it must scale to rapid changes in data volume, variety, and demand as new satellites launch, more products come online, and users rely increasingly on the service. We are addressing these challenges in order to build an efficient and effective on-demand JPSS data service. For example, on-demand subsetting by many users at once may overload a server's processing capacity or its disk bandwidth - unless alleviated by spatial indexing, geolocation transforms, or pre-tiling and caching. Filtering by variable (/ band / layer) may also alleviate network loads, and provide fine-grained variable selection; to that end we are investigating how best to provide random access into the variety of spatiotemporal JPSS data products. Finally, producing tailored products (derivatives, aggregations) can boost flexibility for end users; but some tailoring operations may impose significant server loads

  4. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  5. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  6. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  7. Proposal for SICSeG guidelines for rehabilitation after anatomical shoulder prosthesis in concentric shoulder osteoarthritis.

    Fusaro, I; Orsini, S; Stignani, S; Creta, D; Cava, F C; Benedetti, M G

    2013-06-01

    The purpose of this paper is to provide up-to-date guidelines on rehabilitation after anatomical shoulder prosthesis for concentric shoulder osteoarthritis, as previous guidelines date back to late 1970s and are no longer adequate due to the evolution of prosthesis models and surgical techniques. The physiatric committee of the Italian Society of Shoulder and Elbow Surgery (SICSeG-Società Italiana di Chirurgia della Spalla e del Gomito) performed a search for all the existing literature related to rehabilitation after shoulder replacement. A total of 29 papers concerning shoulder rehabilitation were reviewed. In addition, the main Italian orthopedic surgeons and physiatrists dealing with shoulder surgery and rehabilitation were interviewed to obtain indications when literature was not conclusive. From literature evaluation and expert consultation, we produced guidelines concerning: patient evaluation by means of adequate rating scales, preoperative treatment, early intermediate and advanced postoperative phases, rehabilitation of scapulo-thoracic joint, return to work and sports, length of rehabilitation and follow-up. This proposal for guidelines was presented during the 11th SICSeG Congress on May 2012 and to the main scientific societies concerned in shoulder surgery and rehabilitation. A consensus conference is needed in order to formalize and make them usable from all the professional figures involved in this field.

  8. Fabrication and characterization of DLC coated microdimples on hip prosthesis heads.

    Choudhury, Dipankar; Ay Ching, Hee; Mamat, Azuddin Bin; Cizek, Jan; Abu Osman, Noor Azuan; Vrbka, Martin; Hartl, Martin; Krupka, Ivan

    2015-07-01

    Diamond like carbon (DLC) is applied as a thin film onto substrates to obtain desired surface properties such as increased hardness and corrosion resistance, and decreased friction and wear rate. Microdimple is an advanced surface modification technique enhancing the tribological performance. In this study, DLC coated microdimples were fabricated on hip prosthesis heads and their mechanical, material and surface properties were characterized. An Electro discharge machining (EDM) oriented microdrilling was utilized to fabricate a defined microdimple array (diameter of 300 µm, depth of 70 µm, and pitch of 900 µm) on stainless steel (SS) hip prosthesis heads. The dimpled surfaces were then coated by hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) layers by using a magnetron sputtering technology. A preliminary tribology test was conducted on these fabricated surfaces against a ceramic ball in simulated hip joint conditions. It was found that the fabricated dimples were perpendicular to the spherical surfaces and no cutting-tools wear debris was detected inside the individual dimples. The a-C:H and Ta-C coatings increased the hardness at both the dimple edges and the nondimpled region. The tribology test showed a significant reduction in friction coefficient for coated surfaces regardless of microdimple arrays: the lowest friction coefficient was found for the a-C:H samples (µ = 0.084), followed by Ta-C (µ = 0.119), as compared to the SS surface (µ = 0.248). © 2014 Wiley Periodicals, Inc.

  9. In vivo operation of the Boston 15-channel wireless subretinal visual prosthesis

    Shire, Douglas B.; Doyle, Patrick; Kelly, Shawn K.; Gingerich, Marcus D.; Chen, Jinghua; Cogan, Stuart F.; Drohan, William A.; Mendoza, Oscar; Theogarajan, Luke; Wyatt, John; Rizzo, Joseph F.

    2010-02-01

    This presentation concerns the engineering development of the Boston visual prosthesis for restoring useful vision to patients blind with degenerative retinal disease. A miniaturized, hermetically-encased, 15-channel wirelessly-operated retinal prosthetic was developed for implantation and pre-clinical studies in Yucatan mini-pig animal models. The prosthesis conforms to the eye and drives a microfabricated polyimide stimulating electrode array having sputtered iridium oxide electrodes. This array is implanted into the subretinal space using a specially-designed ab externo surgical technique; the bulk of the prosthesis is on the surface of the sclera. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip; secondary power/data receiving coils surround the cornea. Long-term in vitro pulse testing was also performed on the electrodes to ensure their stability over years of operation. Assemblies were first tested in vitro to verify wireless operation of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation pulse strength, duration and frequency were programmed wirelessly using a computer with a custom graphical user interface. Operation of the retinal implant was verified in vivo in 3 minipigs for more than three months by measuring stimulus artifacts on the eye surface using contact lens electrodes.

  10. Chosen-plaintext attack on a joint transform correlator encrypting system

    Barrera, John Fredy; Vargas, Carlos; Tebaldi, Myrian; Torroba, Roberto

    2010-10-01

    We demonstrate that optical encryption methods based on the joint transform correlator architecture are vulnerable to chosen-plaintext attack. An unauthorized user, who introduces three chosen plaintexts in the accessible encryption machine, can obtain the security key code mask. In this contribution, we also propose an alternative method to eliminate ambiguities that allows obtaining the right decrypting key.

  11. A Model for a Single Unmanned Aircraft Systems (UAS) Program Office Managing Joint ISR Capabilities

    2017-10-01

    managing the efforts of medium and high altitude UAS assets from a Joint perspective while employing agile principles versus the duplicative efforts... managed using agile principles , could provide greater capability to the warfighter. Consolidation cost efficiencies became an independent variable...ensure quality and value are delivered. Senior leadership buy in is needed, along with an understanding of agile principles and management style that

  12. The pedicle screw-rod system is an acceptable method of reconstructive surgery after resection of sacroiliac joint tumours

    Yi-Jun Zhou

    2016-03-01

    Full Text Available Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two, sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study.

  13. Coordinated Volt/Var Control in Distribution Systems with Distributed Generations Based on Joint Active and Reactive Powers Dispatch

    Abouzar Samimi

    2016-01-01

    Full Text Available One of the most significant control schemes in optimal operation of distribution networks is Volt/Var control (VVC. Owing to the radial structure of distribution systems and distribution lines with a small X/R ratio, the active power scheduling affects the VVC issue. A Distribution System Operator (DSO procures its active and reactive power requirements from Distributed Generations (DGs along with the wholesale electricity market. This paper proposes a new operational scheduling method based on a joint day-ahead active/reactive power market at the distribution level. To this end, based on the capability curve, a generic reactive power cost model for DGs is developed. The joint active/reactive power dispatch model presented in this paper motivates DGs to actively participate not only in the energy markets, but also in the VVC scheme through a competitive market. The proposed method which will be performed in an offline manner aims to optimally determine (i the scheduled active and reactive power values of generation units; (ii reactive power values of switched capacitor banks; and (iii tap positions of transformers for the next day. The joint active/reactive power dispatch model for daily VVC is modeled in GAMS and solved with the DICOPT solver. Finally, the plausibility of the proposed scheduling framework is examined on a typical 22-bus distribution test network over a 24-h period.

  14. Joint estimation of the fractional differentiation orders and the unknown input for linear fractional non-commensurate system

    Belkhatir, Zehor

    2015-11-05

    This paper deals with the joint estimation of the unknown input and the fractional differentiation orders of a linear fractional order system. A two-stage algorithm combining the modulating functions with a first-order Newton method is applied to solve this estimation problem. First, the modulating functions approach is used to estimate the unknown input for a given fractional differentiation orders. Then, the method is combined with a first-order Newton technique to identify the fractional orders jointly with the input. To show the efficiency of the proposed method, numerical examples illustrating the estimation of the neural activity, considered as input of a fractional model of the neurovascular coupling, along with the fractional differentiation orders are presented in both noise-free and noisy cases.

  15. Joint Economic Lot Sizing Optimization in a Supplier-Buyer Inventory System When the Supplier Offers Decremental Temporary Discounts

    Diana Puspita Sari

    2012-02-01

    Full Text Available This research discusses mathematical models of joint economic lot size optimization in a supplier-buyer inventory system in a situation when the supplier offers decremental temporary discounts during a sale period. Here, the sale period consists of n phases and the phases of discounts offered descend as much as the number of phases. The highest discount will be given when orders are placed in the first phase while the lowest one will be given when they are placed in the last phase. In this situation, the supplier attempts to attract the buyer to place orders as early as possible during the sale period. The buyers will respon these offers by ordering a special quantity in one of the phase. In this paper, we propose such a forward buying model with discount-proportionally-distributed time phases. To examine the behaviour of the proposed model, we conducted numerical experiments. We assumed that there are three phases of discounts during the sale period. We then compared the total joint costs of special order placed in each phase for two scenarios. The first scenario is the case of independent situation – there is no coordination between the buyer and the supplie-, while the second scenario is the opposite one, the coordinated model. Our results showed the coordinated model outperform the independent model in terms of producing total joint costs. We finally conducted a sensitivity analyzis to examine the other behaviour of the proposed model. Keywords: supplier-buyer inventory system, forward buying model, decremental temporary discounts, joint economic lot sizing, optimization.

  16. Joint ventures

    Sørensen, Karsten Engsig

    Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret......Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret...

  17. Automated estimation of hip prosthesis migration: a feasibility study

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  18. Golf hand prosthesis performance of transradial amputees.

    Carey, Stephanie L; Wernke, Matthew M; Lura, Derek J; Kahle, Jason T; Dubey, Rajiv V; Highsmith, M Jason

    2015-06-01

    Typical upper limb prostheses may limit sports participation; therefore, specialized terminal devices are often needed. The purpose of this study was to evaluate the ability of transradial amputees to play golf using a specialized terminal device. Club head speed, X-factor, and elbow motion of two individuals with transradial amputations using an Eagle Golf terminal device were compared to a non-amputee during a golf swing. Measurements were collected pre/post training with various stances and grips. Both prosthesis users preferred a right-handed stance initially; however, after training, one preferred a left-handed stance. The amputees had slower club head speeds and a lower X-factor compared to the non-amputee golfer, but increased their individual elbow motion on the prosthetic side after training. Amputees enjoyed using the device, and it may provide kinematic benefits indicated by the increase in elbow flexion on the prosthetic side. The transradial amputees were able to swing a golf club with sufficient repetition, form, and velocity to play golf recreationally. Increased elbow flexion on the prosthetic side suggests a potential benefit from using the Eagle Golf terminal device. Participating in recreational sports can increase amputees' health and quality of life. © The International Society for Prosthetics and Orthotics 2014.

  19. Adaptive observer for the joint estimation of parameters and input for a coupled wave PDE and infinite dimensional ODE system

    Belkhatir, Zehor

    2016-08-05

    This paper deals with joint parameters and input estimation for coupled PDE-ODE system. The system consists of a damped wave equation and an infinite dimensional ODE. This model describes the spatiotemporal hemodynamic response in the brain and the objective is to characterize brain regions using functional Magnetic Resonance Imaging (fMRI) data. For this reason, we propose an adaptive estimator and prove the asymptotic convergence of the state, the unknown input and the unknown parameters. The proof is based on a Lyapunov approach combined with a priori identifiability assumptions. The performance of the proposed observer is illustrated through some simulation results.

  20. Providing Health Sciences Services in a Joint-Use Distributed Learning Library System: An Organizational Case Study.

    Enslow, Electra; Fricke, Suzanne; Vela, Kathryn

    2017-01-01

    The purpose of this organizational case study is to describe the complexities librarians face when serving a multi-campus institution that supports both a joint-use library and expanding health sciences academic partnerships. In a system without a centralized health science library administration, liaison librarians are identifying dispersed programs and user groups and collaborating to define their unique service and outreach needs within a larger land-grant university. Using a team-based approach, health sciences librarians are communicating to integrate research and teaching support, systems differences across dispersed campuses, and future needs of a new community-based medical program.