WorldWideScience

Sample records for johnson noise thermometer

  1. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    International Nuclear Information System (INIS)

    Greenen, Adam; Pearce, Jonathan; Cruickshank, David; Bramley, Paul

    2015-01-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  2. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    Energy Technology Data Exchange (ETDEWEB)

    Greenen, Adam; Pearce, Jonathan [National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, (United Kingdom); Cruickshank, David; Bramley, Paul [Metrosol Limited, Plum Park Estate, Watling Street, Paulerspury, Northamptonshire, NN12 6LQ, (United Kingdom)

    2015-07-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  3. In-situ calibration of nuclear-plant platinum resistance thermometers using Johnson noise methods. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Shepard, R.L.

    1983-06-01

    Methods for in situ calibration of reactor plant platinum resistance thermometers using Johnson noise measurements were tested in the laboratory and in two operating reactors: Diablo Canyon and Sequoyah. The Johnson noise methods provide an absolute measurement of the thermometer temperature and can be compared with the dc calibration of the thermometers to confirm their calibration without removing the thermometers from the plant coolant loops. Inaccuracies of less than 0.1% were obtained with these methods for ideal situations where the noise measuring equipment could be connected directly to the installed thermometer terminals. For measurements made at the ends of long extension cables, inaccuracies were 0.5 to 1.0%, at best. Extension cables must be optimized and well characterized electrically to achieve such accuracies. Other factors that affect the accuracy of these methods were evaluated

  4. In situ calibration of nuclear plant resistance thermometers using Johnson noise. Draft

    International Nuclear Information System (INIS)

    Blalock, T.V.; Roberts, M.J.; Shepard, R.L.

    1984-01-01

    Methods have been demonstrated in operating nuclear plants for the in situ calibration of resistance thermometers with agreement between measured noise temperatures and dc calibration temperatures well within these required by the plant. A comparison of the results of Johnson noise power testing results and uncertainties, the requirements for accuracy, and PRT calibration tolerances is shown. The methods use Johnson noise measurements and provide an absolute calibration independent of the prior dc calibration. The methods include techniques for characterization of the installed extension cables and the quantitative determination of induced EMI and its effect on the calibration. The techniques are applicable to ordinary 4-wire platinum resistance thermometers operating over their entire design temperature range and to extension cables of about 100 ft length. Careful attention needs to be paid to the choice or cables, location of terminal boxes, and grounding and shielding practices in the plant installation to achieve comparable results

  5. Survey on Johnson noise thermometry for temperature instrumentation

    International Nuclear Information System (INIS)

    Hwang, I. K.; Kim, Y. K.; Kim, J. S.; Moon, B. S.

    2002-01-01

    Johnson Noise Thermometry is an drift-free temperature measurement method which is able to maintain the best accuracy without calibration for a long period. Resistance Temperature Detectors (RTDs) and Thermocouples used widely in power plants have the drift problem which causes a measurement error. Despite the advantage of Johnson Noise thermometry, it has not been used because it is very sensitive to electromagnetic noise and environment. It also requires more complicated signal processing methods. This paper presents the characteristics of Johnson Noise thermometry and various implementation method proposed over the past decades time period. The key factor in development of a noise thermometer is how to extract the tiny noise signal from the sensor and discriminate out the unnecessary noise interference from the environments. The new digital technology of fast signal processing skill will useful to challenge the existing problems fir commercialization of noise thermometry

  6. Measurement time and statistics for a noise thermometer with a synthetic-noise reference

    Science.gov (United States)

    White, D. R.; Benz, S. P.; Labenski, J. R.; Nam, S. W.; Qu, J. F.; Rogalla, H.; Tew, W. L.

    2008-08-01

    This paper describes methods for reducing the statistical uncertainty in measurements made by noise thermometers using digital cross-correlators and, in particular, for thermometers using pseudo-random noise for the reference signal. First, a discrete-frequency expression for the correlation bandwidth for conventional noise thermometers is derived. It is shown how an alternative frequency-domain computation can be used to eliminate the spectral response of the correlator and increase the correlation bandwidth. The corresponding expressions for the uncertainty in the measurement of pseudo-random noise in the presence of uncorrelated thermal noise are then derived. The measurement uncertainty in this case is less than that for true thermal-noise measurements. For pseudo-random sources generating a frequency comb, an additional small reduction in uncertainty is possible, but at the cost of increasing the thermometer's sensitivity to non-linearity errors. A procedure is described for allocating integration times to further reduce the total uncertainty in temperature measurements. Finally, an important systematic error arising from the calculation of ratios of statistical variables is described.

  7. SQUID-based noise thermometer for sub-Millikelvin refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Marco; Beyer, Joern; Klemm, Monique [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany); Alivaliollahi, Sassan; Barthelmess, Henry [Magnicon GmbH, Barkhausenweg 11, 22339 Hamburg (Germany)

    2015-07-01

    The magnetic field fluctuation thermometer (MFFT) is a high-accuracy SQUID-based noise thermometer suitable for sub-Kelvin thermometry. A highly sensitive low-Tc SQUID magnetometer detects inductively the magnetic field fluctuation above a metal surface. The fluctuations are generated by the thermal activated noise currents inside the metal body that is thermally anchored to the temperature stage to be measured. The spectral shape is independent of temperature as the electrical conductivity is constant and the geometry is fixed. The magnetic noise power spectral amplitudes at any frequencies are directly proportional to temperature. Hence, only one reference measurement at a known temperature is required for calibration. A complete MFFT thermometer system for the temperature range of ca. 4 K down to <10 mK is commercially available. We have now developed an integrated MFFT with an extended range of operation down to <1 mK. For this purpose the sensitivity of the SQUID sensor has been increased, the metal body geometry modified and the magnetic shielding of the MFFT module improved. These modifications make it possible to obtain a thermometer noise temperature of <10 μK. We discuss the rationale for our MFFT configuration and present numerical simulations and experimental results.

  8. Digital signal processing for the Johnson noise thermometry: a time series analysis of the Johnson noise

    International Nuclear Information System (INIS)

    Moon, Byung Soo; Hwang, In Koo; Chung, Chong Eun; Kwon, Kee Choon; David, E. H.; Kisner, R.A.

    2004-06-01

    In this report, we first proved that a random signal obtained by taking the sum of a set of signal frequency signals generates a continuous Markov process. We used this random signal to simulate the Johnson noise and verified that the Johnson noise thermometry can be used to improve the measurements of the reactor coolant temperature within an accuracy of below 0.14%. Secondly, by using this random signal we determined the optimal sampling rate when the frequency band of the Johnson noise signal is given. Also the results of our examination on how good the linearity of the Johnson noise is and how large the relative error of the temperature could become when the temperature increases are described. Thirdly, the results of our analysis on a set of the Johnson noise signal blocks taken from a simple electric circuit are described. We showed that the properties of the continuous Markov process are satisfied even when some channel noises are present. Finally, we describe the algorithm we devised to handle the problem of the time lag in the long-term average or the moving average in a transient state. The algorithm is based on the Haar wavelet and is to estimate the transient temperature that has much smaller time delay. We have shown that the algorithm can track the transient temperature successfully

  9. Elimination of noise peak for signal processing in Johnson noise thermometry development

    International Nuclear Information System (INIS)

    Hwang, I. G.; Moon, B. S.; Jeong, J. E.; Jeo, Y. H.; Kisner, Roger A.

    2003-01-01

    The internal and external noise is the most considering obstacle in development of Johnson Noise Thermometry system. This paper addresses an external noise elimination issue of the Johnson Noise Thermometry system which is underway of development in collaboration between KAERI and ORNL. Although internal random noise is canceled by Cross Power Spectral Density function, a continuous wave penetrating into the electronic circuit is eliminated by the difference of peaks between Johnson signal and external noise. The elimination logic using standard deviation of CPSD and energy leakage problem in discrete CPSD function are discussed in this paper

  10. Survey, applications, and prospects of Johnson noise thermometry

    International Nuclear Information System (INIS)

    Blalock, T.V.; Shepard, R.L.

    1981-01-01

    Significant progress in the field of Johnson noise thermometry has occurred since the 1971 survey of Kamper. This paper will review the foundation work of Johnson noise thermometry, survey the basic methods which do not utilize quantum devices for noise thermometry for industrial temperatures, and present some applications of noise thermometry in temperature scale metrology and process temperature instrumentation. 35 references

  11. Signal processing method for Johnson noise thermometry

    International Nuclear Information System (INIS)

    Hwang, I. G.; Moon, B. S.; Kinser, Rpger

    2003-01-01

    The development of Johnson Noise Thermometry requires a high sensitive preamplifier circuit to pick up the temperature-related noise on the sensing element. However, the random noise generated in this amplification circuit causes a significant erroneous influence to the measurement. This paper describes signal processing mechanism of the Johnson Noise Thermometry system which is underway of development in collaboration between KAERI and ORNL. It adopts two identical amplifier channels and utilizes a digital signal processing technique to remove the independent noise of each channel. The CPSD(Cross Power Spectral Density) function is used to cancel the independent noise and the differentiation of narrow or single frequency peak from the CPSD data separates the common mode electromagnetic interference noise

  12. A Ratiometric Method for Johnson Noise Thermometry Using a Quantized Voltage Noise Source

    Science.gov (United States)

    Nam, S. W.; Benz, S. P.; Martinis, J. M.; Dresselhaus, P.; Tew, W. L.; White, D. R.

    2003-09-01

    Johnson Noise Thermometry (JNT) involves the measurement of the statistical variance of a fluctuating voltage across a resistor in thermal equilibrium. Modern digital techniques make it now possible to perform many functions required for JNT in highly efficient and predictable ways. We describe the operational characteristics of a prototype JNT system which uses digital signal processing for filtering, real-time spectral cross-correlation for noise power measurement, and a digitally synthesized Quantized Voltage Noise Source (QVNS) as an AC voltage reference. The QVNS emulates noise with a constant spectral density that is stable, programmable, and calculable in terms of known parameters using digital synthesis techniques. Changes in analog gain are accounted for by alternating the inputs between the Johnson noise sensor and the QVNS. The Johnson noise power at a known temperature is first balanced with a synthesized noise power from the QVNS. The process is then repeated by balancing the noise power from the same resistor at an unknown temperature. When the two noise power ratios are combined, a thermodynamic temperature is derived using the ratio of the two QVNS spectral densities. We present preliminary results where the ratio between the gallium triple point and the water triple point is used to demonstrate the accuracy of the measurement system with a standard uncertainty of 0.04 %.

  13. Noise thermometry - a new temperature measuring method

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Rittinghaus, K.F.

    1975-01-01

    The thermal Johnson-Niquist noise is the basis of noise thermometry. This temperature measuring method is, e.g., of interest insofar as the noise thermometer gives absolute values as a primary thermometer and is in principle extensively independent of environmental influences and material properties. The resistance values of the measuring probe are about 10 Ohm to a few kOhm. The demands of electronics are high, the self-noise of the measuring apparatus must be as small as possible; a comparative measuring method is advantageous. 1 to 2,500 K are given as a possible temperature range. An accuracy of 0.1% could be achieved in laboratory measurements. Temperature measurements to be used in operation in a few nuclear reactors are mentioned. (HP/LH) [de

  14. Development of high frequency and wide bandwidth Johnson noise thermometry

    International Nuclear Information System (INIS)

    Crossno, Jesse; Liu, Xiaomeng; Kim, Philip; Ohki, Thomas A.; Fong, Kin Chung

    2015-01-01

    We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an analog multiplier operating at 2 GHz, auto- and cross-correlated Johnson noise measurements are performed in the temperature range of 3 to 300 K, achieving a sensitivity of 5.5 mK (110 ppm) in 1 s of integration time. This setup allows us to measure the thermal conductance of a boron nitride encapsulated monolayer graphene device over a wide temperature range. Our data show a high power law (T ∼ 4) deviation from the Wiedemann-Franz law above T ∼ 100 K

  15. A noise thermometry investigation of the melting point of gallium at the NIM

    Science.gov (United States)

    Zhang, J. T.; Xue, S.

    2006-06-01

    This paper describes a study of the melting point of gallium with the new NIM Johnson noise thermometer (JNT). The new thermometer adopts the structure of switching correlator and commutator with the reference resistor maintained at the triple point of water. The electronic system of the new thermometer is basically the same as the current JNT, but the preamplifiers have been improved slightly. This study demonstrates that examining the characteristics of the noise signals in the frequency domain is of critical importance in constructing an improved new thermometer, where a power spectral analysis is found to be critical in establishing appropriate grounding for the new thermometer. The new JNT is tested on measurements of the thermodynamic temperature of the melting point of gallium, which give the thermodynamic temperature of 302.9160 K, with an overall integration time of 190 h and a combined standard uncertainty of 9.4 mK. The uncertainty analysis indicates that a standard combined uncertainty of 3 mK could be achieved with the new thermometer over an integration period of 1750 h.

  16. Progress in Noise Thermometry at 505 K and 693 K Using Quantized Voltage Noise Ratio Spectra

    Science.gov (United States)

    Tew, W. L.; Benz, S. P.; Dresselhaus, P. D.; Coakley, K. J.; Rogalla, H.; White, D. R.; Labenski, J. R.

    2010-09-01

    Technical advances and new results in noise thermometry at temperatures near the tin freezing point and the zinc freezing point using a quantized voltage noise source (QVNS) are reported. The temperatures are derived by comparing the power spectral density of QVNS synthesized noise with that of Johnson noise from a known resistance at both 505 K and 693 K. Reference noise is digitally synthesized so that the average power spectra of the QVNS match those of the thermal noise, resulting in ratios of power spectra close to unity in the low-frequency limit. Three-parameter models are used to account for differences in impedance-related time constants in the spectra. Direct comparison of noise temperatures to the International Temperature Scale of 1990 (ITS-90) is achieved in a comparison furnace with standard platinum resistance thermometers. The observed noise temperatures determined by operating the noise thermometer in both absolute and relative modes, and related statistics together with estimated uncertainties are reported. The relative noise thermometry results are combined with results from other thermodynamic determinations at temperatures near the tin freezing point to calculate a value of T - T 90 = +4(18) mK for temperatures near the zinc freezing point. These latest results achieve a lower uncertainty than that of our earlier efforts. The present value of T - T 90 is compared to other published determinations from noise thermometry and other methods.

  17. Johnson-Nyquist noise and the Casimir force between real metals at nonzero temperature

    International Nuclear Information System (INIS)

    Bimonte, Giuseppe

    2008-01-01

    It has been well known for a long time that all lossy conductors at finite temperature display an electronic noise, the Johnson-Nyquist noise, arising from the thermal agitation of electric charges inside the conductor. The existence of this noise implies that two nearby discharged conductors at finite temperature should repel each other, as a result of the electrodynamic interaction between the Johnson-Nyquist currents in either conductor and the eddy currents they induce in the other. It is suggested that this force is at the origin of the recently discovered large repulsive correction to the thermal Casimir force between two lossy metallic plates. Further support for this physical picture is obtained by studying a simple system of two linear noisy antennas. Using elementary concepts from circuit theory, we show that the repulsive force engendered by the Johnson-Nyquist noise results in the same kind of thermodynamic inconsistencies found in the Casimir problem. We show that all inconsistencies are however resolved if account is taken of capacitive effects associated with the end points of the antennas. Our findings therefore suggest that capacitive effects resulting from the finite size of the plates may be essential for a resolution of the analogous problems met in the thermal Casimir effect

  18. Noise in the wire: The real impact of wire resistance for the Johnson(-like) noise based secure communicator

    International Nuclear Information System (INIS)

    Kish, Laszlo B.; Scheuer, Jacob

    2010-01-01

    We re-evaluate the impact of wire resistance on the noise voltage and current in the Johnson(-like) noise based secure communicator, correcting the result presented in [J. Scheuer, A. Yariv, Phys. Lett. A 359 (2006) 737]. The analysis shown here is based on the fluctuation-dissipation and the linear response theorems. The results indicate that the impact of wire resistance in practical communicators is significantly lower than the previous estimation.

  19. Cold atoms near superconductors: atomic spin coherence beyond the Johnson noise limit

    International Nuclear Information System (INIS)

    Kasch, B; Hattermann, H; Cano, D; Judd, T E; Zimmermann, C; Kleiner, R; Koelle, D; Fortagh, J; Scheel, S

    2010-01-01

    We report on the measurement of atomic spin coherence near the surface of a superconducting niobium wire. As compared to normal conducting metal surfaces, the atomic spin coherence is maintained for time periods beyond the Johnson noise limit. The result provides experimental evidence that magnetic near-field noise near the superconductor is strongly suppressed. Such long atomic spin coherence times near superconductors open the way towards the development of coherently coupled cold atom/solid state hybrid quantum systems with potential applications in quantum information processing and precision force sensing.

  20. High level white noise generator

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Blalock, T.V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application

  1. High level white noise generator

    Science.gov (United States)

    Borkowski, Casimer J.; Blalock, Theron V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application.

  2. Use of SP-100 thermometry technology to improve operation of electric power plants

    International Nuclear Information System (INIS)

    Shepard, R.L.

    1996-01-01

    Control of the nuclear power source for the SP-100 electric power supply required a thermometer that would be 1% accurate at temperatures to 1,100 C with no drift and unattended operation for more than 7 years in moderate radiation environment. Johnson noise thermometers had been developed by Oak Ridge National Laboratory originally for nuclear fuel centerline temperature measurements were believed to be able to provide this performance. They were then adapted for use in the SP-100. This Johnson noise technology also has direct application to two problems in the electric power plant: in situ calibration of conventional resistance thermometers installed in steam systems at temperatures up to about 560 C and measurement of combustion chamber temperatures up to bout 1,100 C. Both capacities require measurement of Johnson noise in harsh industrial environments. The final development and transfer of the SP-100 technology to the electric power sector is currently being supported by the Electric Power Research Institute (EPRI)

  3. Measurement of the Boltzmann constant by Johnson noise thermometry using a superconducting integrated circuit

    Science.gov (United States)

    Urano, C.; Yamazawa, K.; Kaneko, N.-H.

    2017-12-01

    We report on our measurement of the Boltzmann constant by Johnson noise thermometry (JNT) using an integrated quantum voltage noise source (IQVNS) that is fully implemented with superconducting integrated circuit technology. The IQVNS generates calculable pseudo white noise voltages to calibrate the JNT system. The thermal noise of a sensing resistor placed at the temperature of the triple point of water was measured precisely by the IQVNS-based JNT. We accumulated data of more than 429 200 s in total (over 6 d) and used the Akaike information criterion to estimate the fitting frequency range for the quadratic model to calculate the Boltzmann constant. Upon detailed evaluation of the uncertainty components, the experimentally obtained Boltzmann constant was k=1.380 6436× {{10}-23} J K-1 with a relative combined uncertainty of 10.22× {{10}-6} . The value of k is relatively -3.56× {{10}-6} lower than the CODATA 2014 value (Mohr et al 2016 Rev. Mod. Phys. 88 035009).

  4. Noise thermometer

    Energy Technology Data Exchange (ETDEWEB)

    Von Brixy, H. [Forschungszentrum Juelich GmbH (Germany); Kakuta, Tsunemi

    1996-03-01

    The noise thermometry (NT) is a temperature measuring method by which the absolute temperature measurement can be performed with a very high accuracy and without any influence of ambient environments and of the thermal history of its NT sensor (electric resistor). Hence it is quite suitable for application as a standard thermometry to the in-situ temperature calibration of incore thermocouples. The KFA Juelich had played a pioneering role in the development of NT and applied the results successfully to the AVR for testing its feasibility. In this report, all about the NT including its principle, sensor elements and system configurations are presented together with the experiences in the AVR and the results of investigation to apply it to high temperature measurement. The NT can be adopted as a standard method for incore temperature measurement and in situ temperature calibration in the HTTR. (author). 85 refs.

  5. Noise thermometer

    International Nuclear Information System (INIS)

    Von Brixy, H.; Kakuta, Tsunemi.

    1996-03-01

    The noise thermometry (NT) is a temperature measuring method by which the absolute temperature measurement can be performed with a very high accuracy and without any influence of ambient environments and of the thermal history of its NT sensor (electric resistor). Hence it is quite suitable for application as a standard thermometry to the in-situ temperature calibration of incore thermocouples. The KFA Juelich had played a pioneering role in the development of NT and applied the results successfully to the AVR for testing its feasibility. In this report, all about the NT including its principle, sensor elements and system configurations are presented together with the experiences in the AVR and the results of investigation to apply it to high temperature measurement. The NT can be adopted as a standard method for incore temperature measurement and in situ temperature calibration in the HTTR. (author). 85 refs

  6. Johnson Noise Thermometry in the range 505 K to 933 K

    Science.gov (United States)

    Tew, Weston; Labenski, John; Nam, Sae Woo; Benz, Samuel; Dresselhaus, Paul; Martinis, John

    2006-03-01

    The International Temperature Scale of 1990 (ITS-90) is an artifact-based temperature scale, T90, designed to approximate thermodynamic temperature T. The thermodynamic errors of the ITS-90, characterized as the value of T-T90, only recently have been quantified by primary thermodynamic methods. Johnson Noise Thermometry (JNT) is a primary method which can be applied over wide temperature ranges, and NIST is currently using JNT to determine T-T90 in the range 505 K to 933 K, overlapping both acoustic gas-based and radiation-based thermometry. Advances in digital electronics have now made the computationally intensive processing required for JNT viable using noise voltage correlation in the frequency domain. We have also optimized the design of the 5-wire JNT temperature probes to minimize electromagnetic interference and transmission line effects. Statistical uncertainties under 50 μK/K are achievable using relatively modest bandwidths of ˜100 kHz. The NIST JNT system will provide critical data for T-T90 linking together the highly accurate acoustic gas-based data at lower temperatures with the higher-temperature radiation-based data, forming the basis for a new International Temperature Scale with greatly improved thermodynamic accuracy.

  7. Effect of on-chip filter on Coulomb blockade thermometer

    International Nuclear Information System (INIS)

    Roschier, L; Penttilä, J S; Gunnarsson, D; Prunnila, M; Meschke, M; Savin, A

    2012-01-01

    Coulomb Blockade Thermometer (CBT) is a primary thermometer based on electric conductance of normal tunnel junction arrays. One limitation for CBT use at the lowest temperatures has been due to environmental noise heating. To improve on this limitation, we have done measurements on CBT sensors fabricated with different on-chip filtering structures in a dilution refrigerator with a base temperature of 10 mK. The CBT sensors were produced with a wafer scale tunnel junction process. We present how the different on-chip filtering schemes affect the limiting saturation temperatures and show that CBT sensors with proper on-chip filtering work at temperatures below 20 mK and are tolerant to noisy environment.

  8. A Determination of the Ratio of the Zinc Freezing Point to the Tin Freezing Point by Noise Thermometry

    Science.gov (United States)

    Labenski, J. R.; Tew, W. L.; Benz, S. P.; Nam, S. W.; Dresselhaus, P.

    2008-02-01

    A Johnson-noise thermometer (JNT) has been used with a quantized voltage noise source (QVNS), as a calculable reference to determine the ratio of temperatures near the Zn freezing point to those near the Sn freezing point. The temperatures are derived in a series of separate measurements comparing the synthesized noise power from the QVNS with that of Johnson noise from a known resistance. The synthesized noise power is digitally programed to match the thermal noise powers at both temperatures and provides the principle means of scaling the temperatures. This produces a relatively flat spectrum for the ratio of spectral noise densities, which is close to unity in the low-frequency limit. The data are analyzed as relative spectral ratios over the 4.8 to 450 kHz range averaged over a 3.2 kHz bandwidth. A three-parameter model is used to account for differences in time constants that are inherently temperature dependent. A drift effect of approximately -6 μK·K-1 per day is observed in the results, and an empirical correction is applied to yield a relative difference in temperature ratios of -11.5 ± 43 μK·K-1 with respect to the ratio of temperatures assigned on the International Temperature Scale of 1990 (ITS-90). When these noise thermometry results are combined with results from acoustic gas thermometry at temperatures near the Sn freezing point, a value of T - T 90 = 7 ± 30 mK for the Zn freezing point is derived.

  9. Johnson noise and the thermal Casimir effect

    International Nuclear Information System (INIS)

    Bimonte, Giuseppe

    2007-01-01

    We study the thermal interaction between two nearby thin metallic wires, at finite temperature. It is shown that the Johnson currents in the wires give rise, via inductive coupling, to a repulsive force between them. This thermal interaction exhibits all the puzzling features found recently in the thermal Casimir effect for lossy metallic plates, suggesting that the physical origin of the difficulties encountered in the Casimir problem resides in the inductive coupling between the Johnson currents inside the plates. We show that in our simple model all puzzles are resolved if account is taken of capacitive effects associated with the end points of the wires. Our findings suggest that capacitive finite-size effects may play an important role in the resolution of the analogous problems met in the thermal Casimir effect

  10. Thermometers: Understand the Options

    Science.gov (United States)

    ... the options Thermometers come in a variety of styles. Understand the different types of thermometers and how ... MA. Fever in infants and children: Pathophysiology and management. http://www.uptodate.com/home. Accessed July 23, ...

  11. Information theoretically secure, enhanced Johnson noise based key distribution over the smart grid with switched filters.

    Science.gov (United States)

    Gonzalez, Elias; Kish, Laszlo B; Balog, Robert S; Enjeti, Prasad

    2013-01-01

    We introduce a protocol with a reconfigurable filter system to create non-overlapping single loops in the smart power grid for the realization of the Kirchhoff-Law-Johnson-(like)-Noise secure key distribution system. The protocol is valid for one-dimensional radial networks (chain-like power line) which are typical of the electricity distribution network between the utility and the customer. The speed of the protocol (the number of steps needed) versus grid size is analyzed. When properly generalized, such a system has the potential to achieve unconditionally secure key distribution over the smart power grid of arbitrary geometrical dimensions.

  12. Critical analysis of the Bennett-Riedel attack on secure cryptographic key distributions via the Kirchhoff-Law-Johnson-noise scheme.

    Science.gov (United States)

    Kish, Laszlo B; Abbott, Derek; Granqvist, Claes G

    2013-01-01

    Recently, Bennett and Riedel (BR) (http://arxiv.org/abs/1303.7435v1) argued that thermodynamics is not essential in the Kirchhoff-law-Johnson-noise (KLJN) classical physical cryptographic exchange method in an effort to disprove the security of the KLJN scheme. They attempted to demonstrate this by introducing a dissipation-free deterministic key exchange method with two batteries and two switches. In the present paper, we first show that BR's scheme is unphysical and that some elements of its assumptions violate basic protocols of secure communication. All our analyses are based on a technically unlimited Eve with infinitely accurate and fast measurements limited only by the laws of physics and statistics. For non-ideal situations and at active (invasive) attacks, the uncertainly principle between measurement duration and statistical errors makes it impossible for Eve to extract the key regardless of the accuracy or speed of her measurements. To show that thermodynamics and noise are essential for the security, we crack the BR system with 100% success via passive attacks, in ten different ways, and demonstrate that the same cracking methods do not function for the KLJN scheme that employs Johnson noise to provide security underpinned by the Second Law of Thermodynamics. We also present a critical analysis of some other claims by BR; for example, we prove that their equations for describing zero security do not apply to the KLJN scheme. Finally we give mathematical security proofs for each BR-attack against the KLJN scheme and conclude that the information theoretic (unconditional) security of the KLJN method has not been successfully challenged.

  13. Electrical Maxwell Demon and Szilard Engine Utilizing Johnson Noise, Measurement, Logic and Control

    Science.gov (United States)

    Kish, Laszlo Bela; Granqvist, Claes-Göran

    2012-01-01

    We introduce a purely electrical version of Maxwell's demon which does not involve mechanically moving parts such as trapdoors, etc. It consists of a capacitor, resistors, amplifiers, logic circuitry and electronically controlled switches and uses thermal noise in resistors (Johnson noise) to pump heat. The only types of energy of importance in this demon are electrical energy and heat. We also demonstrate an entirely electrical version of Szilard's engine, i.e., an information-controlled device that can produce work by employing thermal fluctuations. The only moving part is a piston that executes work, and the engine has purely electronic controls and it is free of the major weakness of the original Szilard engine in not requiring removal and repositioning the piston at the end of the cycle. For both devices, the energy dissipation in the memory and other binary informatics components are insignificant compared to the exponentially large energy dissipation in the analog part responsible for creating new information by measurement and decision. This result contradicts the view that the energy dissipation in the memory during erasure is the most essential dissipation process in a demon. Nevertheless the dissipation in the memory and information processing parts is sufficient to secure the Second Law of Thermodynamics. PMID:23077525

  14. Electrical Maxwell demon and Szilard engine utilizing Johnson noise, measurement, logic and control.

    Directory of Open Access Journals (Sweden)

    Laszlo Bela Kish

    Full Text Available We introduce a purely electrical version of Maxwell's demon which does not involve mechanically moving parts such as trapdoors, etc. It consists of a capacitor, resistors, amplifiers, logic circuitry and electronically controlled switches and uses thermal noise in resistors (Johnson noise to pump heat. The only types of energy of importance in this demon are electrical energy and heat. We also demonstrate an entirely electrical version of Szilard's engine, i.e., an information-controlled device that can produce work by employing thermal fluctuations. The only moving part is a piston that executes work, and the engine has purely electronic controls and it is free of the major weakness of the original Szilard engine in not requiring removal and repositioning the piston at the end of the cycle. For both devices, the energy dissipation in the memory and other binary informatics components are insignificant compared to the exponentially large energy dissipation in the analog part responsible for creating new information by measurement and decision. This result contradicts the view that the energy dissipation in the memory during erasure is the most essential dissipation process in a demon. Nevertheless the dissipation in the memory and information processing parts is sufficient to secure the Second Law of Thermodynamics.

  15. Electrical Maxwell demon and Szilard engine utilizing Johnson noise, measurement, logic and control.

    Science.gov (United States)

    Kish, Laszlo Bela; Granqvist, Claes-Göran

    2012-01-01

    We introduce a purely electrical version of Maxwell's demon which does not involve mechanically moving parts such as trapdoors, etc. It consists of a capacitor, resistors, amplifiers, logic circuitry and electronically controlled switches and uses thermal noise in resistors (Johnson noise) to pump heat. The only types of energy of importance in this demon are electrical energy and heat. We also demonstrate an entirely electrical version of Szilard's engine, i.e., an information-controlled device that can produce work by employing thermal fluctuations. The only moving part is a piston that executes work, and the engine has purely electronic controls and it is free of the major weakness of the original Szilard engine in not requiring removal and repositioning the piston at the end of the cycle. For both devices, the energy dissipation in the memory and other binary informatics components are insignificant compared to the exponentially large energy dissipation in the analog part responsible for creating new information by measurement and decision. This result contradicts the view that the energy dissipation in the memory during erasure is the most essential dissipation process in a demon. Nevertheless the dissipation in the memory and information processing parts is sufficient to secure the Second Law of Thermodynamics.

  16. Critical analysis of the Bennett-Riedel attack on secure cryptographic key distributions via the Kirchhoff-Law-Johnson-noise scheme.

    Directory of Open Access Journals (Sweden)

    Laszlo B Kish

    Full Text Available Recently, Bennett and Riedel (BR (http://arxiv.org/abs/1303.7435v1 argued that thermodynamics is not essential in the Kirchhoff-law-Johnson-noise (KLJN classical physical cryptographic exchange method in an effort to disprove the security of the KLJN scheme. They attempted to demonstrate this by introducing a dissipation-free deterministic key exchange method with two batteries and two switches. In the present paper, we first show that BR's scheme is unphysical and that some elements of its assumptions violate basic protocols of secure communication. All our analyses are based on a technically unlimited Eve with infinitely accurate and fast measurements limited only by the laws of physics and statistics. For non-ideal situations and at active (invasive attacks, the uncertainly principle between measurement duration and statistical errors makes it impossible for Eve to extract the key regardless of the accuracy or speed of her measurements. To show that thermodynamics and noise are essential for the security, we crack the BR system with 100% success via passive attacks, in ten different ways, and demonstrate that the same cracking methods do not function for the KLJN scheme that employs Johnson noise to provide security underpinned by the Second Law of Thermodynamics. We also present a critical analysis of some other claims by BR; for example, we prove that their equations for describing zero security do not apply to the KLJN scheme. Finally we give mathematical security proofs for each BR-attack against the KLJN scheme and conclude that the information theoretic (unconditional security of the KLJN method has not been successfully challenged.

  17. Ion thermometers - nuclear reactor applications

    International Nuclear Information System (INIS)

    Rosenkranz, J.; Jakes, D.

    The principle is briefly described of ion thermometers and the effects are reported of radiation on the ion crystal properties. The results show that ion thermometers are applicable for in-core measurements. (J.P.)

  18. Zero Thermal Noise in Resistors at Zero Temperature

    Science.gov (United States)

    Kish, Laszlo B.; Niklasson, Gunnar A.; Granqvist, Claes-Göran

    2016-06-01

    The bandwidth of transistors in logic devices approaches the quantum limit, where Johnson noise and associated error rates are supposed to be strongly enhanced. However, the related theory — asserting a temperature-independent quantum zero-point (ZP) contribution to Johnson noise, which dominates the quantum regime — is controversial and resolution of the controversy is essential to determine the real error rate and fundamental energy dissipation limits of logic gates in the quantum limit. The Callen-Welton formula (fluctuation-dissipation theorem) of voltage and current noise for a resistance is the sum of Nyquist’s classical Johnson noise equation and a quantum ZP term with a power density spectrum proportional to frequency and independent of temperature. The classical Johnson-Nyquist formula vanishes at the approach of zero temperature, but the quantum ZP term still predicts non-zero noise voltage and current. Here, we show that this noise cannot be reconciled with the Fermi-Dirac distribution, which defines the thermodynamics of electrons according to quantum-statistical physics. Consequently, Johnson noise must be nil at zero temperature, and non-zero noise found for certain experimental arrangements may be a measurement artifact, such as the one mentioned in Kleen’s uncertainty relation argument.

  19. Noise measurements on proximity effect bridges

    International Nuclear Information System (INIS)

    Decker, S.K.; Mercereau, J.E.

    1975-01-01

    Audio frequency noise density measurements were performed on weakly superconducting proximity effect bridges on using a cooled transformer and room temperature low noise preamplifier. The noise temperature of the measuring system is approximately 4 0 K for a 0.9 Ω resistor. Noise density was measured as a function of bias current and temperature for the bridges. Excess noise above that expected from Johnson noise for a resistor equal to the dynamic resistance of the bridges was observed in the region near the critical current of the device. At high currents compared to the critical current, the noise density closely approaches that given by Johnson noise

  20. 21 CFR 880.2920 - Clinical mercury thermometer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...

  1. A portable storage maximum thermometer

    International Nuclear Information System (INIS)

    Fayart, Gerard.

    1976-01-01

    A clinical thermometer storing the voltage corresponding to the maximum temperature in an analog memory is described. End of the measurement is shown by a lamp switch out. The measurement time is shortened by means of a low thermal inertia platinum probe. This portable thermometer is fitted with cell test and calibration system [fr

  2. Response to Scheuer-Yariv: 'A classical key-distribution system based on Johnson (like) noise-how secure?'

    International Nuclear Information System (INIS)

    Kish, L.B.

    2006-01-01

    We point out that the claims in the comment-paper of Scheuer and Yariv are either irrelevant or incorrect. The idealized Kirchoff-loop-Johnson-like-noise (KLJN) scheme is totally secure therefore it is more secure than idealized quantum communication schemes which can never be totally secure because of the inherent noise processes in those communication schemes and the statistical nature of eavesdropper detection based on error statistics. On the other hand, with sufficient resources, a practical/non-ideal realization of the KLJN cipher can arbitrarily approach the idealized limit and outperform even the idealized quantum communicator schemes because the non-ideality-effects are determined and controlled by the design. The cable resistance issue analyzed by Scheuer and Yariv is a good example for that because the eavesdropper has insufficient time window to build a sufficient statistics and the actual information leak can be designed. We show that Scheuer's and Yariv's numerical result of 1% voltage drop supports higher security than that of quantum communicators. Moreover, choosing thicker or shorter wires can arbitrarily reduce this voltage drop further; the same conclusion holds even according to the equations of Scheuer and Yariv

  3. Completion of Level 4 Milestone M4AT-15OR2301039 for the Johnson Noise Thermometry for Drift-free Temperature Measurements Work Package AT-15OR230103

    Energy Technology Data Exchange (ETDEWEB)

    Britton Jr, Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-14

    This memorandum constitutes our September 2015 level 4 milestone for the project entitled “Johnson Noise Thermometry for Drift-free Temperature Measurements” and satisfies the Milestone/Activity (Conclude HFIR field demonstration of JNT prototype). The progress summary describes the work performed to complete the subject milestone.

  4. A silicon nanowire heater and thermometer

    Science.gov (United States)

    Zhao, Xingyan; Dan, Yaping

    2017-07-01

    In the thermal conductivity measurements of thermoelectric materials, heaters and thermometers made of the same semiconducting materials under test, forming a homogeneous system, will significantly simplify fabrication and integration. In this work, we demonstrate a high-performance heater and thermometer made of single silicon nanowires (SiNWs). The SiNWs are patterned out of a silicon-on-insulator wafer by CMOS-compatible fabrication processes. The electronic properties of the nanowires are characterized by four-probe and low temperature Hall effect measurements. The I-V curves of the nanowires are linear at small voltage bias. The temperature dependence of the nanowire resistance allows the nanowire to be used as a highly sensitive thermometer. At high voltage bias, the I-V curves of the nanowire become nonlinear due to the effect of Joule heating. The temperature of the nanowire heater can be accurately monitored by the nanowire itself as a thermometer.

  5. A calorimetric particle detector using an iridium superconducting phase transition thermometer

    International Nuclear Information System (INIS)

    Frank, M.; Dummer, D.; Cooper, S.; Igalson, J.; Proebst, F.; Seidel, W.

    1994-01-01

    We report on a calorimetric particles detector consisting of an 18.3 g silicon crystal and an iridium superconducting phase transition thermometer. The cryogenic calorimeter and the associated apparatus are described in detail. The pulses from irradiation with an α-particle source have a large unexpected overshoot in addition to the component expected from a naive thermal model. The pulse height spectrum displays an energy resolution of 1 percent FWHM at 6 MeV and good linearity. The noise, electrothermal feedback, and position dependence are discussed. (orig.)

  6. Cryogenic Thermometer Calibration Facility at CERN

    CERN Document Server

    Balle, C; Thermeau, J P

    1998-01-01

    A cryogenic thermometer calibration facility has been designed and is being commissioned in preparation for the very stringent requirements on the temperature control of the LHC superconducting magnets. The temperature is traceable in the 1.5 to 30 K range to standards maintained in a national metrological laboratory by using a set of Rhodium-Iron temperature sensors of metrological quality. The calibration facility is designed for calibrating simultaneously 60 industrial cryogenic thermometers in the 1.5 K to 300 K temperature range, a thermometer being a device that includes both a temperature sensor and the wires heat-intercept. The thermometers can be calibrated in good and degraded vacuum or immersed in the surrounding fluid and at different Joule self-heating conditions that match those imposed by signal conditioners used in large cryogenic machinery. The calibration facility can be operated in an automatic mode and all the control and safety routines are handled by a Programmable Logic Controller (PLC)...

  7. Design of a Toolbox of RNA Thermometers.

    Science.gov (United States)

    Sen, Shaunak; Apurva, Divyansh; Satija, Rohit; Siegal, Dan; Murray, Richard M

    2017-08-18

    Biomolecular temperature sensors can be used for efficient control of large-volume bioreactors, for spatiotemporal imaging and control of gene expression, and to engineer robustness to temperature in biomolecular circuit design. Although RNA-based sensors, called "thermometers", have been investigated in both natural and synthetic contexts, an important challenge is to design diverse responses to temperature differing in sensitivity and threshold. We address this issue by constructing a library of RNA thermometers based on thermodynamic computations and experimentally measuring their activities in cell-free biomolecular "breadboards". Using free energies of the minimum free energy structures as well as melt profile computations, we estimated that a diverse set of temperature responses were possible. We experimentally found a wide range of responses to temperature in the range 29-37 °C with fold-changes varying over 3-fold around the starting thermometer. The sensitivities of these responses ranged over 10-fold around the starting thermometer. We correlated these measurements with computational expectations, finding that although there was no strong correlation for the individual thermometers, overall trends of diversity, fold-changes, and sensitivities were similar. These results present a toolbox of RNA-based circuit elements with diverse temperature responses.

  8. An inexpensive high-temperature optical fiber thermometer

    International Nuclear Information System (INIS)

    Moore, Travis J.; Jones, Matthew R.; Tree, Dale R.; Allred, David D.

    2017-01-01

    An optical fiber thermometer consists of an optical fiber whose tip is coated with a highly conductive, opaque material. When heated, this sensing tip becomes an isothermal cavity that emits like a blackbody. This emission is used to predict the sensing tip temperature. In this work, analytical and experimental research has been conducted to further advance the development of optical fiber thermometry. An inexpensive optical fiber thermometer is developed by applying a thin coating of a high-temperature cement onto the tip of a silica optical fiber. An FTIR spectrometer is used to detect the spectral radiance exiting the fiber. A rigorous mathematical model of the irradiation incident on the detection system is developed. The optical fiber thermometer is calibrated using a blackbody radiator and inverse methods are used to predict the sensing tip temperature when exposed to various heat sources. - Highlights: • An inexpensive coating for an optical fiber thermometer sensing tip is tested. • Inverse heat transfer methods are used to estimate the sensing tip temperature. • An FTIR spectrometer is used as the detector to test the optical fiber thermometer using various heat sources.

  9. High temperature measurement by noise thermometry

    International Nuclear Information System (INIS)

    Decreton, M.C.

    1982-06-01

    Noise thermometry has received a lot of attention for measurements of temperatures in the high range around 1000-2000 deg. K. For these measurements, laboratory type experiments have been mostly performed. These have shown the interest of the technique when long term stability, high precision and insensibility to external conditions are concerned. This is particularly true for measurements in nuclear reactors where important drifts due to irradiation effects are experienced with other measurement techniques, as thermocouple for instance. Industrial noise thermometer experiments have not been performed extensively up to now. The subject of the present study is the development of a 1800 deg. K noise thermometer for nuclear applications. The measurement method is based on a generalized noise power approach. The rms noise voltage (Vsub(s)) and noise current (Isub(s)) are successively measured on the resistive sensor. The same quantities are also measured on a dummy short circuited probe (Vsub(d) and Isub(d)). The temperature is then deduced from these measured values by the following formula: cTsub(s) = (Vsub(s) 2 - Vsub(d) 2 )(Vsub(s)/Isub(s) - Vsub(d)/Isub(d)) - 1 , where c is a constant and Tsub(s) the absolute temperature of the sensor. This approach has the particular advantage of greatly reducing the sensibility to environmental perturbations on the leads and to the influence of amplifier noise sources. It also eliminates the necessity of resistance measurement and keeps the electronic circuits as simple as possible

  10. Dan Johnson's impact on hearing research

    Science.gov (United States)

    Shotland, Lawrence I.

    2003-04-01

    Daniel L. Johnson is well known for his many technical contributions to noise research. Throughout a long and distinguished career at Wright-Patterson Air Force Base, Dan published the results of several significant experiments, including his landmark experiments on asymptotic threshold shift and exposure to impulse noise. His work in the area of noise exposure laid much of the groundwork for a greater understanding of the physiologic response to hazardous noise, much of which has since been incorporated in national and international standards. Dan is highly regarded for his tireless work on technical and advisory committees in noise, and most recently, ototoxicity. Throughout his career, Dan has adhered to a self-imposed standard of intellectual honesty and discovery. Dan's most recent endeavor, the development of a personal noise dosimeter designed for self-monitoring by the employee, is characteristic of his creativity and energy. Perhaps less well known are his contributions over the years to the success of his younger colleagues. He has accomplished this in an unselfish and egalitarian manner, oftentimes challenging and even contradicting his own research. The focus of this talk will elaborate on these facets of Dan's professional contributions.

  11. Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer.

    Science.gov (United States)

    Poveda, Vanessa de Brito; Nascimento, Ariane de Souza

    2016-01-01

    To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of ±0.2ºC. The operating room temperature remained between 19 and 21ºC. The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24°C lower (ptemperatura realizadas por meio de um termômetro timpânico por infravermelho e por um termômetro esofágico, durante o período intraoperatório. Realizou-se um estudo longitudinal, de medidas repetidas, incluindo sujeitos com idade igual ou superior a 18 anos, submetidos à cirurgia oncológica eletiva do sistema digestório, com duração da anestesia de, no mínimo, 1 hora. As medidas de temperatura eram realizadas, ao mesmo tempo, por meio de um termômetro esofágico calibrado e por termômetro timpânico por infravermelho calibrado, com precisão de leitura em laboratório de ±0,2ºC. A temperatura da sala operatória permaneceu entre 19 e 21ºC. Foram incluídos 51 pacientes, em sua maioria homens (51%), brancos (80,4%). Todos os pacientes foram aquecidos com o sistema de ar forçado aquecido, em média por 264,14 minutos (DP = 87,7). As duas medidas de temperatura não tiveram comportamento diferente ao longo do tempo (p = 0,2205), mas a medida timpânica foi consistentemente menor em 1,24°C (p temperaturas mais

  12. A low-temperature (4-300K) constant volume gas thermometer

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1976-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300K may be obtained. The principle is outlined, then the gas thermometer and its auxiliary equipment are briefly described; the corrections to be applied to the results are given and a table shows the values obtained [fr

  13. Modified ultrafast thermometer UFT-M and temperature measurements during Physics of Stratocumulus Top (POST

    Directory of Open Access Journals (Sweden)

    W. Kumala

    2013-08-01

    Full Text Available A modified UFT-M version of the ultrafast airborne thermometer UFT, aimed at in-cloud temperature measurements, was designed for the Physics of Stratocumulus Top (POST field campaign. Improvements in its construction resulted in the sensor's increased reliability, which provided valuable measurements in 15 of the 17 flights. Oversampling the data allowed for the effective correction of the artefacts resulting from the interference with electromagnetic transmissions from on-board avionic systems and the thermal noise resulting from the sensor construction. The UFT-M records, when averaged to the 1.4 and 55 m resolutions, compared to the similar records of a thermometer in a Rosemount housing, indicate that the housing distorts even low-resolution airborne temperature measurements. Data collected with the UFT-M during the course of POST characterise the thermal structure of stratocumulus and capping inversion with the maximum resolution of ~1 cm. In this paper, examples of UFT-M records are presented and discussed.

  14. Evaluation of flow-induced vibration of thermometer well for JOYO

    International Nuclear Information System (INIS)

    Isozaki, Kazunori; Tomita, Naoki

    1997-05-01

    Sodium leak accident of MONJU was caused high cycles fatigue damage of thermometer well by flow-induced vibration. It was due to the symmetric vortex shedding which was occurred rear flow of thermometer well. So, Thermometer wells installed in primary and secondary heat transport systems of JOYO were evaluated of flow-induced vibration. Evaluation of flow-induced vibration of thermometer well was done checking of flow-induced vibration base on authorized design report for JOYO, evaluation of summary flow-induced vibration by natural frequency of thermometer well in sodium as cantilever models, and evaluation based on small velocity rule of ASME Code Section III Appendix N-1300. By this result, thermometer wells (12B piping of secondary cooling system) were not satisfied requirement to avoid flow-induced vibration by small velocity rule. Therefore, Detailed vibration characteristic analysis, water flow-induced vibration test, dumping test and evaluation of structural integrity were carried out. These results, vibration amplitude of well on the tip was 0.13 mm (vibration non-dimensional amplitude of 0.015) and peak stress of 2.9 kg/mm 2 is occurred. Thermometer wells (12B piping of secondary cooling system) which occurred peak stress by flow vibration was confirmed enough to satisfy 5.3 kg/mm 2 of design fatigue limit. (author)

  15. Measurement of body temperature by use of auricular thermometers versus rectal thermometers in dogs with otitis externa.

    Science.gov (United States)

    González, A Michelle; Mann, F A; Preziosi, Diane E; Meadows, Richard L; Wagner-Mann, Colette C

    2002-08-01

    To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. Prospective study. 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.

  16. Measuring Systems for Thermometer Calibration in Low-Temperature Range

    Science.gov (United States)

    Szmyrka-Grzebyk, A.; Lipiński, L.; Manuszkiewicz, H.; Kowal, A.; Grykałowska, A.; Jancewicz, D.

    2011-12-01

    The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium-iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.

  17. Controlling mercury spills in laboratories with a thermometer exchange program

    Energy Technology Data Exchange (ETDEWEB)

    McLouth, Lawrence D.

    2002-03-25

    This paper presents a case for replacing mercury thermometers with their organic-liquid-filled counterparts. A review of liquid-in glass-thermometers is given. In addition, a brief summary of mercury's health effects and exposure limits is presented. Spill cleanup methods and some lessons learned from our experience are offered as well. Finally, an overview of the mercury thermometer exchange program developed at Lawrence Berkeley National Laboratory is presented.

  18. Semiconductor resistance thermometer for the temperature range 300-0.3 K

    International Nuclear Information System (INIS)

    Zinov'eva, K.N.; Zarubin, L.I.; Nemish, I.Yu.; Vorobkalo, F.M.; Boldarev, S.T.; AN Ukrainskoj SSR, Kiev. Inst. Poluprovodnikov)

    1979-01-01

    Thermometric characteristics of semiconductor resistor thermometers for the temperature range from 300 to 0.3 K and from 77 to 0.3 K are given. Temperature dependence of thermometer resistances in the 300-1.3 K range was measured in cryostats with pumping-out of N 2 , H 2 and 4 He. For measurements below 1.3 K use was made of a 3 H- 4 He dissolving cryostat. The accuracy of measuring temperatures in the 1.3-0.3 K range is not below +-0.003 K, the error in determining thermometer resistances does not exceed 1%. The analysis of obtained thermometric characteristics of several series of semiconductor resistance thermometers showed that observed insignificant spread of resistances of thermometers in one series and identity of characteristics allows them to be used without preliminary calibration for relatively coarse measurements in the range from 3O0 to 0.3 K. Besides, it has been found that in the 4.2-0.3 K range the thermometric characteristics represent a straight line in the lgR-Tsup(-n) coordinates, where R is the thermometer resistance, T is the temperature and n=0.5. Thus, the thermometers of the same series can be calibrated only in 2 or 3 reference point measurements

  19. Galileo Chain Thermometer

    Science.gov (United States)

    Ucke, C.; Schlichting, H. J.

    2017-01-01

    This relatively rare thermometer has a rather unusual display: lower temperatures are located at the top of the scale, higher ones at the bottom. A sphere on a chain floats in a suitable liquid, sinking at high temperatures when the density of the liquid decreases and rising in the increased density at low temperatures. With reasonable effort and…

  20. Silicon photonic thermometer operating on multiple polarizations

    DEFF Research Database (Denmark)

    Guan, Xiaowei; Wang, Xiaoyan; Frandsen, Lars Hagedorn

    2016-01-01

    A silicon photonics optical thermometer simultaneously operating on the multiple polarizations is designed and experimentally demonstrated. Measured sensitivities are 86pm/°C and 48pm/°C for the transverse-electric and transverse-magnetic polarizations, respectively.......A silicon photonics optical thermometer simultaneously operating on the multiple polarizations is designed and experimentally demonstrated. Measured sensitivities are 86pm/°C and 48pm/°C for the transverse-electric and transverse-magnetic polarizations, respectively....

  1. The constitution of the heat density of a gamma thermometer

    International Nuclear Information System (INIS)

    Hantouche, C.

    1984-01-01

    This paper's aim is to present the nuclear transfer function of the signal of the γ thermometer used in a PWR reactor. The nuclear transfer function between the linear nuclear power and the γ thermometer heat density has been established. The corresponding computation code has been built up. The results concerning the environment behaviour of the γ thermometer, the heat density axial and radial repartitions, the control rods and the grids' influences are presented and discussed. (orig.)

  2. Adiabatic surface thermometer for improved production braze quality

    International Nuclear Information System (INIS)

    Dittbenner, G.R.

    1975-01-01

    An adiabatic surface thermometer was developed to control automatically the critical temperature-time cycle of a production vacuum-brazing process. Investigations revealed that optimum braze-joint strength required precise control of the brazing temperature. Spot-welded thermocouples could not be used because the spot welds cause surface damage. This thermometer touches the surface and uses a differential thermocouple and heater to measure surface temperature without heat flow, thereby eliminating large errors caused by conduction losses common to conventional spring-loaded thermocouples. Temperatures in air or vacuum are measured to 800 0 C with errors less than 5 0 C. This thermometer has minimized the rejection of production parts, resulting in a cost saving to the U. S. Energy Research and Development Administration

  3. Feasibility of Johnson Noise Thermometry based on Digital Signal Processing Techniques

    International Nuclear Information System (INIS)

    Hwang, In Koo; Kim, Yang Mo

    2014-01-01

    This paper presents an implementation strategy of noise thermometry based on a digital signal processing technique and demonstrates its feasibilities. A key factor in its development is how to extract the small thermal noise signal from other noises, for example, random noise from amplifiers and continuous electromagnetic interference from the environment. The proposed system consists of two identical amplifiers and uses a cross correlation function to cancel the random noise of the amplifiers. Then, the external interference noises are eliminated by discriminating the difference in the peaks between the thermal signal and external noise. The gain of the amplifiers is estimated by injecting an already known pilot signal. The experimental simulation results of signal processing methods have demonstrated that the proposed approach is an effective method in eliminating an external noise signal and performing gain correction for development of the thermometry

  4. Investigation of the integrated effects of irradiating platinum resistance thermometers

    International Nuclear Information System (INIS)

    Neverov, V.A.; Revyakin, Yu.L.

    1993-01-01

    The development of nuclear energy imposes increased demands on the reliability and quality of the information obtained from primary transducers which monitor the basic parameters of current reactor devices. One of these parameters is the temperature of different modules. This is mainly measured by thermoelectric transducers. Resistance thermometers now being adopted into measurement practice. These provide an initial accuracy of better than plus or minus 273 degrees C and also a normalized systematic error component caused by the action of the temperature. However, a systematic error component resulting from the action of the reactor radiation remains undetermined, and this greatly hinders the extensive use of resistance thermometers in reactor devices. Investigations were made using platinum resistance thermometers of different constructions designs. Irradiation took place in sealed ampules. Each of these contained three thermometers. The fluence achieved was varied by placing the ampules at different heights relative to the central plane of the active zone of the reactor. The irradiation temperature was determined by calculation, taking into account the radiative energy release where the irradiation occurred and the helium gap between the thermometer casing and the walls of an SM-2 reactor channel. Following irradiation in the reactor, the resistance thermometers were calibrated in a special thermometric device providing the minimum contact resistance, uniform heating of the samples, and stabilization of the temperature regime

  5. Analysis of an Attenuator Artifact in an Experimental Attack by Gunn-Allison-Abbott Against the Kirchhoff-Law-Johnson-Noise (KLJN) Secure Key Exchange System

    Science.gov (United States)

    Kish, Laszlo B.; Gingl, Zoltan; Mingesz, Robert; Vadai, Gergely; Smulko, Janusz; Granqvist, Claes-Göran

    2015-12-01

    A recent paper by Gunn-Allison-Abbott (GAA) [L. J. Gunn et al., Scientific Reports 4 (2014) 6461] argued that the Kirchhoff-law-Johnson-noise (KLJN) secure key exchange system could experience a severe information leak. Here we refute their results and demonstrate that GAA's arguments ensue from a serious design flaw in their system. Specifically, an attenuator broke the single Kirchhoff-loop into two coupled loops, which is an incorrect operation since the single loop is essential for the security in the KLJN system, and hence GAA's asserted information leak is trivial. Another consequence is that a fully defended KLJN system would not be able to function due to its built-in current-comparison defense against active (invasive) attacks. In this paper we crack GAA's scheme via an elementary current-comparison attack which yields negligible error probability for Eve even without averaging over the correlation time of the noise.

  6. A Non-Mercury Thermometer Alternative for Use in Older Melting Point Apparatuses

    Science.gov (United States)

    Ongley, Lois K.; Kern, Clayton S.; Woods, Barry W.

    2008-01-01

    The State of Maine seeks to eliminate most mercury use. This includes removing mercury thermometers from secondary schools and discouraging Hg use in other educational institutions. Alternatives to mercury thermometers in chemical laboratory work include non-mercury thermometers, temperature probes, and thermocouples. In organic chemistry mercury…

  7. Validation of Calculations in a Digital Thermometer Firmware

    Science.gov (United States)

    Batagelj, V.; Miklavec, A.; Bojkovski, J.

    2014-04-01

    State-of-the-art digital thermometers are arguably remarkable measurement instruments, measuring outputs from resistance thermometers and/or thermocouples. Not only that they can readily achieve measuring accuracies in the parts-per-million range, but they also incorporate sophisticated algorithms for the transformation calculation of the measured resistance or voltage to temperature. These algorithms often include high-order polynomials, exponentials and logarithms, and must be performed using both standard coefficients and particular calibration coefficients. The numerical accuracy of these calculations and the associated uncertainty component must be much better than the accuracy of the raw measurement in order to be negligible in the total measurement uncertainty. In order for the end-user to gain confidence in these calculations as well as to conform to formal requirements of ISO/IEC 17025 and other standards, a way of validation of these numerical procedures performed in the firmware of the instrument is required. A software architecture which allows a simple validation of internal measuring instrument calculations is suggested. The digital thermometer should be able to expose all its internal calculation functions to the communication interface, so the end-user can compare the results of the internal measuring instrument calculation with reference results. The method can be regarded as a variation of the black-box software validation. Validation results on a thermometer prototype with implemented validation ability show that the calculation error of basic arithmetic operations is within the expected rounding error. For conversion functions, the calculation error is at least ten times smaller than the thermometer effective resolution for the particular probe type.

  8. Random-Resistor-Random-Temperature Kirchhoff-Law-Johnson-Noise (RRRT-KLJN Key Exchange

    Directory of Open Access Journals (Sweden)

    Kish Laszlo B.

    2016-03-01

    Full Text Available We introduce two new Kirchhoff-law-Johnson-noise (KLJN secure key distribution schemes which are generalizations of the original KLJN scheme. The first of these, the Random-Resistor (RR- KLJN scheme, uses random resistors with values chosen from a quasi-continuum set. It is well-known since the creation of the KLJN concept that such a system could work in cryptography, because Alice and Bob can calculate the unknown resistance value from measurements, but the RR-KLJN system has not been addressed in prior publications since it was considered impractical. The reason for discussing it now is the second scheme, the Random Resistor Random Temperature (RRRT- KLJN key exchange, inspired by a recent paper of Vadai, Mingesz and Gingl, wherein security was shown to be maintained at non-zero power flow. In the RRRT-KLJN secure key exchange scheme, both the resistances and their temperatures are continuum random variables. We prove that the security of the RRRT-KLJN scheme can prevail at a non-zero power flow, and thus the physical law guaranteeing security is not the Second Law of Thermodynamics but the Fluctuation-Dissipation Theorem. Alice and Bob know their own resistances and temperatures and can calculate the resistance and temperature values at the other end of the communication channel from measured voltage, current and power-flow data in the wire. However, Eve cannot determine these values because, for her, there are four unknown quantities while she can set up only three equations. The RRRT-KLJN scheme has several advantages and makes all former attacks on the KLJN scheme invalid or incomplete.

  9. Infrared Thermometer: an accurate tool for temperature measurement during renal surgery

    Directory of Open Access Journals (Sweden)

    Giovanni Scala Marchini

    2013-07-01

    Full Text Available Purpose To evaluate infrared thermometer (IRT accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush and 10 without renal cooling (Group 2 - Warm Ischemia. Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT: immediate after clamping (T0, after 2 (T2, 5 (T5 and 10 minutes (T10. Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C. For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C. There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C. For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C. No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio

  10. Ion thermometers in reactor technology

    International Nuclear Information System (INIS)

    Yakesh, D.; Kott, J.; Strnad, M.

    1980-01-01

    The width of the temperature discontinuity and the thermometric stability of the sensors are constant up to very high flux values. The immediate influence of irradiation is reduced to a decrease in the hysteresis of the conduction curve at the phase transition. When the readings of the ion thermometers are compared with the reading of Chromel-Alumel thermocouples, it is observed that the temperature difference amounts to approximately 7/degree/C in the case of thermocouples placed at the sensor socket; the temperature difference decreases to 2/degree/C in the case of the thermocouple junction situated between the electrodes. The good results obtained in the testing of the ion thermometers in nuclear reactors lead to the conclusion that these temperature sensors are promising for checking thermocouples in the core of nuclear power stations

  11. Analytical expressions for transition edge sensor excess noise models

    International Nuclear Information System (INIS)

    Brandt, Daniel; Fraser, George W.

    2010-01-01

    Transition edge sensors (TESs) are high-sensitivity thermometers used in cryogenic microcalorimeters which exploit the steep gradient in resistivity with temperature during the superconducting phase transition. Practical TES devices tend to exhibit a white noise of uncertain origin, arising inside the device. We discuss two candidate models for this excess noise, phase slip shot noise (PSSN) and percolation noise. We extend the existing PSSN model to include a magnetic field dependence and derive a basic analytical model for percolation noise. We compare the predicted functional forms of the noise current vs. resistivity curves of both models with experimental data and provide a set of equations for both models to facilitate future experimental efforts to clearly identify the source of excess noise.

  12. Characteristics of infrared thermometers manufactured in Japan and calibration methods for sky radiant emittance

    International Nuclear Information System (INIS)

    Wang, X.; Horiguchi, I.; Machimura, T.

    1993-01-01

    Infrared thermometers to measure surface temperature have been increasingly adopted in recent years. The characteristics of the IR thermometer, however, are not well known.IR thermometers manufactured in Japan systematically adjust for ambient radiation based on the internal temperature of the thermometer. If, therefore, there is a large difference between the internal temperature of the IR thermometer and the apparent temperature associated with the surrounding radiation, a large error will be induced into the measured surface temperature.The purpose of our research was to determine the characteristics and measurement errors of IR thermometers. Experiments were performed with regard to the following items: (1) Measurement errors related to the internal temperature of the IR thermometer. (2) Linearity of the output signal of the IR thermometer. (3) Response of the output signal to changes in the emissivity setting. (4) Effect of sky radiant emittance on the measured surface temperature. (5) Calibration method for the terrestrial surface.The following is a summary of the results: Measurement error is affected by the internal temperature of the IR thermometer. Measurement accuracy is improved with a controlled internal temperature of 20-30°C. The measurement error becomes larger at emissivity settings under 0.7.The measurement error outdoors was not proportional to the downward longwave radiation, but to the sky radiant temperature measured by the IR thermometer. Calibration for sky radiant emittance was improved by using the difference between sky radiant temperature and air temperature.When the surface temperature measured by the infrared thermometer is plotted against the surface temperature measured by thermocouple, the sky radiant emittance error is obtained from the Y intercept. Additionally, the difference between true temperature and output of the IR thermometer for a reference plate was compared to that obtained for vegetation, and the RMS obtained was

  13. Stability of High Temperature Standard Platinum Resistance Thermometers at High Temperatures

    Directory of Open Access Journals (Sweden)

    Y. A. ABDELAZIZ

    2010-05-01

    Full Text Available An investigation of the stability of high temperature standard platinum resistance thermometers HTSPRTs has been carried out for two different designs thermometers (with nominal resistance 0.25 Ω and 2.5 Ω from two different suppliers. The thermometers were heated for more than 160 hours at temperatures above 960 0C using a vertical furnace with a ceramic block. A study was made of the influence of the heat treatment on the stability of the resistance at the triple point of water, and on the relative resistance W(Ga at the melting point of gallium. The thermometers showed a correlation between the drift note and the values of W(Ga. It was found also that the HTSPRT which has a sensor with strip shaped support and low nominal resistance is more stable than the HTSPRT which has a sensor in the form of a coil wound on silica cross. The 0.25 Ω thermometer has better stability @ 7x10-6 0C (at TPW after 40 hour. Factors affecting the stability and accuracy of HTSPRT also will be discussed.

  14. Dr.Johnson's Dictionary in Miniature

    OpenAIRE

    Imazato, Chiaki

    1988-01-01

    More than hundred 'Johnson's' dictionaries have so far been published not only in English but in other countries, and there are numerous books and articles on Johnson's Dictionary. But few have referred to Johnson's Dictionary in Miniature; nor were there any books or articles on it. Fortunately, however, I've got one copy of Johnson's Dictionary in Miniature, which was published in 1806. Johnson's Dictionary (1755) has 41,677 entries, whereas Johnson's Dictionary in Miniature 23,439 entr...

  15. Johnson and Johnson strives to implement best practices by year 2000

    International Nuclear Information System (INIS)

    Kauffman, H.A.

    1999-01-01

    Johnson and Johnson is the world's most comprehensive broadly-based manufacturer of health care products. Utilizing a decentralized management philosophy, the 188 operating companies around the world operate independently. Although Johnson and Johnson is not an energy intensive company, it has had a coordinated energy program since 1972. In the 1990s, however, a renewed focus, prompted by the link between energy usage and pollution, led to some very aggressive energy reduction goals to be completed by the end of the year 2000. To assist the operating companies in meeting these goals. a comprehensive set of Best Practices was developed. They cover all facility energy-using equipment and maintenance practices. Inputs included projects completed at Johnson and Johnson facilities worldwide, best practices from several US government voluntary programs, and recommendations from consultants and engineering firms. The end product is now being used worldwide to benchmark the progress. To ensure that these Best Practices are incorporated into new construction as well as the existing facilities, the authors developed their New Facility Design Criteria which is in the format that architectural/engineering firms can easily utilize. They originally validated the Best Practices in two retrofit pilots and two new buildings. They all achieved significant energy savings. As of April 1999, they have completed 62% of the Best Practices at the 96 facilities in the US and Puerto Rico. Twenty-four of these facilities had achieved an 80% completion level in 1998 and were recognized with the internal recognition plaque. Through full implementation of these Best Practices, Johnson and Johnson feel confident that they will be able to meet the Year 2000 energy reduction goals

  16. Johnson Mendonca

    Indian Academy of Sciences (India)

    Johnson Mendonca. Articles written in Bulletin of Materials Science. Volume 26 Issue 3 April 2003 pp 355-364 Modeling Studies. Modeling of droplet dynamic and thermal behaviour during spray deposition · N S Mahesh Johnson Mendonca M K Muralidhara B K Muralidhara C Ramachandra · More Details Abstract Fulltext ...

  17. 27 CFR 30.23 - Use of precision hydrometers and thermometers.

    Science.gov (United States)

    2010-04-01

    ... hydrometers and thermometers. 30.23 Section 30.23 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO... Use of precision hydrometers and thermometers. Care should be exercised to obtain accurate hydrometer... entire quantity. The hydrometers should be kept clean and free of any oily substance. Immediately before...

  18. Electronic measurement of the Boltzmann constant with a quantum-voltage-calibrated Johnson-noise thermometer

    NARCIS (Netherlands)

    Benz, Samuel; White, D. Rod; Qu, JiFeng; Rogalla, Horst; Tew, Weston

    2010-01-01

    Currently, the CODATA value of the Boltzmann constant is dominated by a single gas-based thermometry measurement with a relative standard uncertainty of 1.8×10−6 [P.J. Mohr, B.N. Taylor, D.B. Newell, CODATA recommended values of the fundamental physical constants: 2006, Rev. Mod. Phys. 80 (2008)

  19. Stability of High Temperature Standard Platinum Resistance Thermometers at High Temperatures

    OpenAIRE

    Y. A. ABDELAZIZ; F. M. MEGAHED

    2010-01-01

    An investigation of the stability of high temperature standard platinum resistance thermometers HTSPRTs has been carried out for two different designs thermometers (with nominal resistance 0.25 Ω and 2.5 Ω) from two different suppliers. The thermometers were heated for more than 160 hours at temperatures above 960 0C using a vertical furnace with a ceramic block. A study was made of the influence of the heat treatment on the stability of the resistance at the triple point of water, and on the...

  20. Computer model for noise in the dc Squid

    International Nuclear Information System (INIS)

    Tesche, C.D.; Clarke, J.

    1976-08-01

    A computer model for the dc SQUID is described which predicts signal and noise as a function of various SQUID parameters. Differential equations for the voltage across the SQUID including the Johnson noise in the shunted junctions are integrated stepwise in time

  1. High speed infrared radiation thermometer, system, and method

    Science.gov (United States)

    Markham, James R.

    2002-01-01

    The high-speed radiation thermometer has an infrared measurement wavelength band that is matched to the infrared wavelength band of near-blackbody emittance of ceramic components and ceramic thermal barrier coatings used in turbine engines. It is comprised of a long wavelength infrared detector, a signal amplifier, an analog-to-digital converter, an optical system to collect radiation from the target, an optical filter, and an integral reference signal to maintain a calibrated response. A megahertz range electronic data acquisition system is connected to the radiation detector to operate on raw data obtained. Because the thermometer operates optimally at 8 to 12 .mu.m, where emittance is near-blackbody for ceramics, interferences to measurements performed in turbine engines are minimized. The method and apparatus are optimized to enable mapping of surface temperatures on fast moving ceramic elements, and the thermometer can provide microsecond response, with inherent self-diagnostic and calibration-correction features.

  2. The gamma thermometer as a measuring instrument of the nuclear power of a LWR core

    International Nuclear Information System (INIS)

    Hantouche, C.

    1984-07-01

    After a presentation of the gamma thermometer and its environment, this thesis deals with the calibration of a gamma thermometer or determination of the thermal transfer ratio of the signal. Then, the acquisition systems for signals obtained from gamma thermometers installed in PWR nuclear power plants are presented. One deals also with the nuclear transfer function establishment and deconvolution. Then, one deals with the reconstruction of the axial power of an assembly provided with a gamma thermometer. Qualitative and quantitative studies of measurements obtained from this gamma thermometer are finally presented. 64 refs [fr

  3. 76 FR 16447 - ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary...

    Science.gov (United States)

    2011-03-23

    ... workers of ETHICON, A Johnson and Johnson Company, San Angelo, Texas, separated from employment on or... Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary Services, San Angelo, TX; Amended... of ETHICON, a subsidiary of Johnson & Johnson, including on-site leased workers from Kelly Temporary...

  4. Stevens-Johnson Syndrome

    Science.gov (United States)

    ... after blisters form If you have Stevens-Johnson syndrome, several days before the rash develops you may experience: Fever Sore mouth and throat Fatigue Cough Burning eyes When to see a doctor Stevens-Johnson ...

  5. Thermo-Chromium: A Contactless Optical Molecular Thermometer.

    Science.gov (United States)

    Otto, Sven; Scholz, Norman; Behnke, Thomas; Resch-Genger, Ute; Heinze, Katja

    2017-09-07

    The unparalleled excited-state potential-energy landscape of the chromium(III)-based dye [1] 3+ ([Cr(ddpd) 2 ] 3+ ; ddpd=N,N'-dimethyl-N,N'-dipyridin-2-yl-pyridin-2,6-diamine) enables a strong dual emission in the near infrared region. The temperature dependence of this dual emission allows the use of [1] 3+ as an unprecedented molecular ratiometric thermometer in the 210-373 K temperature range in organic and in aqueous media. Incorporation of [1] 3+ in biocompatible nanocarriers, such as 100 nm-sized polystyrene nanoparticles and solutol micelles, provides nanodimensional thermometers operating under physiological conditions. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Thermal Conductivity and Liquid Crystal Thermometers.

    Science.gov (United States)

    Edge, R. D., Ed.

    1993-01-01

    Describes using stock liquid crystal postcards as inexpensive classroom thermometers. Also suggests using these postcards as a good visual temperature indicator for classroom demonstrations such as temperature gradients. One such activity is provided. (MVL)

  7. Reliability of an infrared forehead skin thermometer for core temperature measurements

    NARCIS (Netherlands)

    Kistemaker, J.A.; Hartog, E.A. den; Daanen, H.A.M.

    2006-01-01

    The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal

  8. High-Temperature Compatible Nickel Silicide Thermometer And Heater For Catalytic Chemical Microreactors

    DEFF Research Database (Denmark)

    Jensen, Søren; Quaade, U.J.; Hansen, Ole

    2005-01-01

    Integration of heaters and thermometers is important for agile and accurate control and measurement of the thermal reaction conditions in microfabricated chemical reactors (microreactors). This paper describes development and operation of nickel silicide heaters and temperature sensors...... for temperatures exceeding 700 °C. The heaters and thermometers are integrated with chemical microreactors for heterogeneous catalytic conversion of gasses, and thermally activated catalytic conversion of CO to CO2 in the reactors is demonstrated. The heaters and thermometers are shown to be compatible...

  9. The Infrared Thermometer in School Science: Teaching Physics with Modern Technologies

    Science.gov (United States)

    Girwidz, Raimund; Ireson, Gren

    2011-01-01

    Infrared thermometers measure temperature from a distance, using the infrared radiation emitted by all objects. These so-called non-contact thermometers make a wide variety of temperature measurement and monitoring activities accessible to school-age students. Portable hand-held sensors also enable new or simplified investigations to be carried…

  10. What can Johnson & Johnson do to remain a giant in the health care industry?

    Science.gov (United States)

    Carter, Tony

    2002-01-01

    As a major Fortune 500 corporation and manufacturer of significant drug products for the pharmaceutical industry, Johnson & Johnson has also had its share of marketing crisis, including the classic case example of The Tylenol Scare in Fall, 1982, so they can appreciate the need for effective marketing performance and customer responsiveness. This article will examine how Johnson & Johnson has adapted to a highly volatile business environment and how they can be benchmarked for highly competitive marketing strategies and practices.

  11. Reporting společnosti Johnson and Johnson, s. r. o.

    OpenAIRE

    Hejnyš, Jaroslav

    2008-01-01

    The thesis describes the financial background that prevails in the company Johnson & Johnson. It contains the most essential processes which are applied in the financial department. Each event is specified in theoretical way and also described in practical examples. Special attention is given to pricing policy, accountancy system and periodic financial closing.

  12. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].

    Science.gov (United States)

    Padilla-Raygoza, Nicolás; Ruiz-Paloalto, M Laura; Díaz-Guerrero, Rosalina; Olvera-Villanueva, Georgina; Maldonado, Angélica; Raygoza-Mendoza, María Del Pilar

    2014-01-01

    To compare body temperature measurements using tympanic, skin and digital axillary thermometers. Hospitalized or outpatient children from the General Hospital Celaya, ISSSTE Hospital Clinic and General Hospital No. 4 IMSS, and the pediatric private service in Celaya, Guanajuato, from 1 day of life until 16 years old, were recruited over a one month period, after their parents signed the consent form. The order of each institution was selected by simple randomization. Body temperatures were measured in triplicate using tympanic, skin and digital axillary thermometers. The sample consisted of 554 children. The Pearson r between the tympanic and digital axillary thermometers was 0.57 to 0.65, with a positive linear relationship (P<.05); between the skin and the digital axillary thermometers, it was between 0.47 and 0.52 with a positive linearrelationship (P<.05). The intra-observer Kappa for the tympanic thermometer was 0.86, and for the inter-observer was 0.77; for the skin thermometer it was 0.82 and 0.67, respectively, and for the digital axillary thermometer it was 0.86 for intra-observer reliability and 0.78 for inter -observer reliability. Tympanic and axillary thermometers showed better precision in measuring the body temperature in children than skin thermometers. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  13. Carl Hirschie Johnson

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. Carl Hirschie Johnson. Articles written in Resonance – Journal of Science Education. Volume 11 Issue 5 May 2006 pp 22-31 General Article. Reminiscences from Pittendrigh's Last PhD Student · Carl Hirschie Johnson · More Details Fulltext PDF ...

  14. Ultrafast Paper Thermometers Based on a Green Sensing Ink.

    Science.gov (United States)

    Tao, Xinglei; Jia, Hanyu; He, Yonglin; Liao, Shenglong; Wang, Yapei

    2017-03-24

    With the use of an ionic liquid as the ultrathermosensitive fluid, a paper thermometer is successfully developed with intrinsic ability of ultrafast response and high stability upon temperature change. The fluidic nature allows the ionic liquid to be easily deposited on paper by pen writing or inkjet printing, affording great promise for large-scale fabrication of low-cost paper sensors. Owing to the advantages of nonvolatilization, excellent continuity and deformability, the thermosensitive ink trapped within the cellulose fibers of paper matrix has no leakage or evaporation at open states, ensuring the excellent stability and repeatability of thermal sensing against arbitrary bending and folding operation. By shortening the heat exchange distance between ionic liquid and samples, it takes only 8 s for the thermometer to reach an electrical equilibrium at a given temperature. Moreover, the paper thermometer can be applied to remotely monitor temperature change with the combination of a wireless communication technology.

  15. Examination of the suitability of noise thermometry for precise in situ calibration of thermocouples in technical processes

    International Nuclear Information System (INIS)

    Fechner, H.

    1988-12-01

    The aim was to determine the achievable accuracy of the noise thermometer developed at the KFA in the range from 0 to 1000 0 C under laboratory conditions. Precision noise temperature measurements at fixed temperature points (triple point of water, freezing point of zinc and silver) were carried out. The fixed point technique and the conventional precision resistance thermometry, which is required to operate the fixed points, were established in accordance with the requirements of accurate (and thus longer lasting) noise temperature measurements. The analysis of all possible sources of error ensured that all systematic or random errors were in the range of a few 10 -5 . The further developed KFA noise thermometers, which can be used under industrial conditions, achieve under laboratory conditions a measuring error of about ±2.5 10 -4 - relative to the thermodynamic temperature scale - in the temperature range from 273.16 K (0.01 0 C) to 1234.894 K (961.744 0 C). Assuming that the individual measured values display a normal distribution, the noise measurements at the zinc and silver point are combined to a mean value, it becomes apparent that the average noise temperatures only deviate by +2 10 -5 (zinc) or +4 10 -5 (silver) from the respective thermodynamic temperature. (orig./HP) [de

  16. Accuracy of the Danish version of the 'distress thermometer'

    DEFF Research Database (Denmark)

    Bidstrup, Pernille Envold; Mertz, Birgitte Goldschmidt; Dalton, Susanne Oksbjerg

    2012-01-01

    Objective: Short screening instruments have been suggested to improve the detection of psychological symptoms. We examined the accuracy of the Danish version of the 'Distress Thermometer'. Methods: Between October 2008 and October 2009, 426 women with newly diagnosed primary breast cancer who were...... operated at the Breast Surgery Clinic of the Rigshospitalet, Copenhagen, were eligible for this study. Of these, 357 participated (84%) and 333 completed a questionnaire. The distress thermometer was evaluated against the 'hospital anxiety and depression scale' (HADS). We also examined the women's wish...

  17. Construction and test of a superconducting phase-transition thermometer for bolometric cryodetectors

    International Nuclear Information System (INIS)

    Meier, H.J.

    1990-10-01

    In the framework of a project for the study of bolometric cryodetectors for the detection of heavy ions a superconducting phase-transition thermometer for the detection of heavy ions was constructed and tested with α particles. The thermometer consists of a 10 nm thick aluminium film, which was evaporated on a sapphire absorber with a typical magnitude of 2.5x2.5 x 0.33 mm 3 . By the method of photolithography the aluminium film was structured in form of a meander. By this at the working point of the thermometer resistances of up to 60 kΩ resulted, so that the signal acquisition was possible with usual readout electronics. Several of these thermometers were constructed, characterized in their properties, and tested. For the study of the detector properties of the thermometers in characterization measurements the width of the phase transitions dT ≅ 2 mK, the temperature dependence of the resistance to dR/dT ≅ 10MΩ/K, the thermal conductivity of the thermal coupling to the cooling bath, and the heat capacity of the bolometers to C ≅ 2 nJ/K were determined.The best energy resolution, which was reached with one of the superconducting phase-transition thermometers, amounts to 50 keV for 5.5 MeV α particles, which corresponds to a relative resolution of 0,9%. By this in the order of magnitude the quality of semiconductor detectors was reached. The best temperature resolution amounts to about 1 μK. (orig./HSI) [de

  18. Low-frequency noise in planar Hall effect bridge sensors

    DEFF Research Database (Denmark)

    Persson, Anders; Bejhedb, R.S.; Bejhed, R.S.

    2011-01-01

    The low-frequency characteristics of planar Hall effect bridge sensors are investigated as function of the sensor bias current and the applied magnetic field. The noise spectra reveal a Johnson-like spectrum at high frequencies, and a 1/f-like excess noise spectrum at lower frequencies, with a kn...

  19. Magnetic disturbance effects in noise thermometry

    International Nuclear Information System (INIS)

    Fischer, M.

    1992-01-01

    Due to the very small measurement signals, a compensation process is used, which presupposes undisturbed signals of the measurement resistance and a compensation resistance as necessary conditions. There is a two-channel control for the measurement and compensation circuit, so that parasitic noise voltages from the incoming leads and the electronics can be eliminated by cross-correlation. The sensor which is designed as a combined thermocouple/noise thermometer sensor, permits continuous measurement of temperature by measuring the thermal voltages and the in situ calibration of the thermocouples at all times, which may have considerable drift of the thermal voltages, depending on environmental effects. Leads designed as thermocouples use ferromagnetic materials, in part. (orig./DG) [de

  20. THE DYNAMIC RESPONSE OF THERMOMETER-WELL ASSEMBLIES.

    Science.gov (United States)

    parameter models of the thermometric system were constructed and gave acceptable agreement with the experimental results. These models can be used to predict the dynamic behavior of any similar thermometer system. (Author)

  1. Application of radio frequency based digital thermometer for real-time monitoring of dairy cattle rectal temperature

    Directory of Open Access Journals (Sweden)

    Tridib Debnath

    2017-09-01

    Full Text Available Aim: Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT data of radio frequency based digital (RFD thermometer with RT data of mercury bulb (MB thermometer in dairy cattle. Materials and Methods: Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Results: Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05 before and after feeding/exercise. An increase (p<0.05 in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. Conclusion: The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle.

  2. Johnson & Johnson Asia Pacific Supply Chain: A Value(less) Chain?

    OpenAIRE

    Wong, Wennie

    2008-01-01

    An increasing number of companies claim to pursue International supply chain management (ISCM), but the empirical evidence of successful implementation programs is still scarce. This project aims to contribute in this area by presenting an review of goals, barriers, and enablers on the road towards effective ISCM by Johnson and Johnson Asia Pacific. In today's highly competitive globalized environment, organizations must seek to develop collaborative partnerships and more effective informatio...

  3. Robert Wood Johnson Foundation

    Science.gov (United States)

    Robert Wood Johnson Foundation Search How We Work Our Focus Areas About RWJF Search Menu How We Work Grants ... Learn more For Grantees and Grantseekers The Robert Wood Johnson Foundation funds a wide array of programs ...

  4. The carbon dioxide thermometer and the cause of global warming

    International Nuclear Information System (INIS)

    Calder, Nigel

    1999-01-01

    Carbon dioxide in the air may be increasing because the world is warming. This possibility, which contradicts the hypothesis of an enhanced greenhouse warming driven by manmade emissions, is here pursued in two ways. First, increments in carbon dioxide are treated as readings of a natural thermometer that tracks global and hemispheric temperature deviations, as gauged by meteorologists' thermometers. Calibration of the carbon dioxide thermometer to conventional temperatures then leads to a history of carbon dioxide since 1856 that diverges from the ice-core record. Secondly, the increments of carbon dioxide can also be accounted for, without reference to temperature, by the combined effects of cosmic rays, El Nino and volcanoes. The most durable effect is due to cosmic rays. A solar wind history, used as a long-term proxy for the cosmic rays, gives a carbon dioxide history similar to that inferred from the global temperature deviations. (author)

  5. Demonstrating the Temperature Dependence of Density via Construction of a Galilean Thermometer

    Science.gov (United States)

    Priest, Marie A.; Padgett, Lea W.; Padgett, Clifford W.

    2011-01-01

    A method for the construction of a Galilean thermometer out of common chemistry glassware is described. Students in a first-semester physical chemistry (thermodynamics) class can construct the Galilean thermometer as an investigation of the thermal expansivity of liquids and the temperature dependence of density. This is an excellent first…

  6. Noise thermometry in nuclear reactors

    International Nuclear Information System (INIS)

    Hoewener, H.

    1985-08-01

    Since in nuclear reactors the measuring sensor cannot be easily replaced, the value of the sensor resistance, as well as the selection of transmission lines with respect to good transmission characteristics of the whole arrangement and minimizing the correlative error terms, must already be optimized when designing a noise thermometer arrangement. The TRARAU computer program was developed for this purpose enabling the influences of the lines to be computed by taking into consideration all the effects occurring through the lines, such as transmission errors and correlative error terms. In order to check the accuracy of the TRARAU computer program a series of laboratory measurements were implemented enabling both the pure transmission behaviour of the line arrangement with respect to the measuring signal to be detected, as well as the overall line error. In all cases this resulted in a very good agreement of the measured values with the computed values. The transmission behaviour of noise thermometer arrangements occuring in practice were studied with the example of two reactor experiments. In both cases it was possible to demonstrate successfully the potential of the computer program TRARAU. As the parametric studies have shown, optimum matching over unlimited band widths is not feasible in principle. By reducing the upper band limit, however, the line error can practically always be kept sufficiently small. With good matching larger band widths can also be used. (orig./HP) [de

  7. Temperature measurement: Development work on noise thermometry and improvement of conventional thermocouples for applications in nuclear process heat (PNP)

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Oehmen, J.; Barbonus, P.; Hans, R.

    1982-06-01

    The behaviour was studied of NiCr-Ni sheathed thermocouples (sheath Inconel 600 or Incoloy 800, insulation MgO) in a helium and carbon atmosphere at temperatures of 950-1150 deg. C. All the thermocouples used retained their functional performance. The insulation resistance tended towards a limit value which is dependent on the temperature and quality of the thermocouple. Temperature measurements were loaded with great uncertainty in the temperature range of 950-1150 deg. C. Recalibrations at the temperature of 950 deg. C showed errors of up to 6%. Measuring sensors were developed which consist of a sheathed double thermocouple with a noise resistor positioned between the two hot junctions. Using the noise thermometer it is possible to recalibrate the thermocouple at any time in situ. A helium system with a high temperature experimental area was developed to test the thermocouples and the combined thermocouple-noise thermometer sensors under true experimental conditions

  8. Radiation Requirements and Testing of Cryogenic Thermometers for the Ilc

    Science.gov (United States)

    Barnett, T.; Filippov, Yu. P.; Filippova, E. Yu.; Mokhov, N. V.; Nakao, N.; Klebaner, A. L.; Korenev, S. A.; Theilacker, J. C.; Trenikhina, J.; Vaziri, K.

    2008-03-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox® and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results.

  9. Radiation requirements and testing of cryogenic thermometers for the ILC

    International Nuclear Information System (INIS)

    Barnett, T.; Filippov, Yu.P.; Mokhov, N.V.; Nakao, N.; Klebaner, A.L.; Korenev, S.A.; Theilacker, J.C.; Trenikhina, J.; Vaziri, K.

    2007-01-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox(reg s ign) and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results

  10. Low-temperature thermometry. Use of a gas thermometer as a calibration standard between 4 and 300 K

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1978-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300 K may be obtained. After some words about low temperature thermometry, the gas thermometer and its auxiliary equipment are described briefly; the corrections to be applied to the results are given and the article ends with a table showing the values obtained [fr

  11. The gamma thermometer

    International Nuclear Information System (INIS)

    Beraud, G.; Hourtoulle, F.

    1983-01-01

    The search for a detecting element capable of permanently measuring localised nuclear output which would also be robust straightforward and reliable led EDF to begin development work on a new type of detector in 1976: the gamma thermometer (THG). After briefly summarising the history of the project this article goes on to describe the principle and structure of the equipment used in EDF's PWR reactors. As a result of the extensive test programme carried out it has been possible to qualify analytical and calibration methods together with the thermal and nuclear models. In conclusion, the development prospects and future of such a detecting device are outlined [fr

  12. Investigations on perturbations of microwave dielectric resonator thermometer

    International Nuclear Information System (INIS)

    Yu, Lili; Zhang, Guangming; Fernicola, V; Lu, Jinchuan

    2017-01-01

    Investigations of antenna probe length, antenna-dielectric distance, cavity filling and humidity on microwave resonator thermometer with respect to Q , spurious mode depression, coupling strength, accuracy, shock resistance or sensitivity were carried out in order to improve the dielectric resonator thermometer performance. Significant improvement of Q and depression of spurious mode coupling were obtained when the antenna length was reduced. It also turns out that the Q and spurious mode coupling strength vary with the distance between dielectric and antenna pin, as well under appropriate antenna length. Filling the cavity with nitrogen increases coupling strength but decrease frequency-temperature sensitivity compared to a vacuum-pumped cavity. Besides, preliminary results on the microwave resonator sensitivity to air humidity were obtained. (technical note)

  13. Process for constructing a gamma thermometer

    International Nuclear Information System (INIS)

    Barbet, M.J.P.; Cohen, B.S.; Robillard, M.

    1982-01-01

    A process is described for constructing a gamma thermometer having a substance absorbing the radiation and a set of thermocouples for measuring the local power in a fuel assembly of a nuclear reactor. A claim is particularly made for the preparation of the tube containing it and for its filling with an inert gas [fr

  14. Accuracy of peripheral thermometers for estimating temperature: a systematic review and meta-analysis.

    Science.gov (United States)

    Niven, Daniel J; Gaudet, Jonathan E; Laupland, Kevin B; Mrklas, Kelly J; Roberts, Derek J; Stelfox, Henry Thomas

    2015-11-17

    Body temperature is commonly used to screen patients for infectious diseases, establish diagnoses, monitor therapy, and guide management decisions. To determine the accuracy of peripheral thermometers for estimating core body temperature in adults and children. MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL Plus from inception to July 2015. Prospective studies comparing the accuracy of peripheral (tympanic membrane, temporal artery, axillary, or oral) thermometers with central (pulmonary artery catheter, urinary bladder, esophageal, or rectal) thermometers. 2 reviewers extracted data on study characteristics, methods, and outcomes and assessed the quality of individual studies. 75 studies (8682 patients) were included. Most studies were at high or unclear risk of patient selection bias (74%) or index test bias (67%). Compared with central thermometers, peripheral thermometers had pooled 95% limits of agreement (random-effects meta-analysis) outside the predefined clinically acceptable range (± 0.5 °C), especially among patients with fever (-1.44 °C to 1.46 °C for adults; -1.49 °C to 0.43 °C for children) and hypothermia (-2.07 °C to 1.90 °C for adults; no data for children). For detection of fever (bivariate random-effects meta-analysis), sensitivity was low (64% [95% CI, 55% to 72%]; I2 = 95.7%; P temperature measurement techniques are limited. Pooled data are associated with interstudy heterogeneity that is not fully explained by stratified and metaregression analyses. Peripheral thermometers do not have clinically acceptable accuracy and should not be used when accurate measurement of body temperature will influence clinical decisions. None.

  15. MEMS Tunneling Micro Thermometer Based onTip Deflection of Bimetallic Cantilever Beam

    Directory of Open Access Journals (Sweden)

    Samrand K. Nezhadian

    2007-10-01

    Full Text Available Micro-electro-mechanical (MEM technology promises to significantly reduce the size, weight and cost of a variety of sensor systems. In this article has been described a highly sensitive novel type of thermometer based on deflection of a “bimetallic” microbeam. The proposed thermometer converts the thermal changes of a cantilevered bimetallic beam of submillimeter size into an electrical signal through tunneling-current modulation. The governing thermo-mechanical equation of a bimetallic cantilever beam has been derived and solved analytically. The obtained results show that the proposed tunneling micro thermometer is very sensitive to temperature changes due to exponential increasing of tunneling current but because of small gap between metallic electrodes, measurable range of temperature changes is small.

  16. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  17. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  18. Thermal noise engines

    OpenAIRE

    Kish, Laszlo B.

    2010-01-01

    Electrical heat engines driven by the Johnson-Nyquist noise of resistors are introduced. They utilize Coulomb's law and the fluctuation-dissipation theorem of statistical physics that is the reverse phenomenon of heat dissipation in a resistor. No steams, gases, liquids, photons, combustion, phase transition, or exhaust/pollution are present here. In these engines, instead of heat reservoirs, cylinders, pistons and valves, resistors, capacitors and switches are the building elements. For the ...

  19. Influence of Thermal Cycling on Cryogenic Thermometers

    CERN Document Server

    Balle, C; Rieubland, Jean Michel; Suraci, A; Togny, F; Vauthier, N

    1999-01-01

    The stringent requirements on temperature control of the superconducting magnets for the Large Hadron Collider (LHC), impose that the cryogenic temperature sensors meet compelling demands such as long-term stability, radiation hardness, readout accuracy better than 5 mK at 1.8 K and compatibility with industrial control equipment. This paper presents the results concerning long-term stability of resistance temperature sensors submitted to cryogenic thermal cycles. For this task a simple test facility has been designed, constructed and put into operation for cycling simultaneously 115 cryogenic thermometers between 300 K and 4.2 K. A thermal cycle is set to last 71/4 hours: 3 hours for either cooling down or warming up the sensors and 1 respectively 1/4 hour at steady temperature conditions at each end of the temperature cycle. A Programmable Logic Controller (PLC) drives automatically this operation by reading 2 thermometers and actuating on 3 valves and 1 heater. The first thermal cycle was accomplished in a...

  20. Thermal properties of superconducting bulk metallic glasses at ultralow temperatures

    International Nuclear Information System (INIS)

    Rothfuss, Daniel Simon

    2013-01-01

    This thesis describes the first investigation of thermal properties of superconducting bulk metallic glasses in the range between 6mK and 300K. Measuring the thermal conductivity provides the possibility to probe the fundamental interactions governing the heat flow in solids. At ultralow temperatures a novel contactless measuring technique was used, which is based on optical heating and paramagnetic temperature sensors that are read out by a SQUID magnetometer. Below the critical temperature T c the results can be described by resonant scattering of phonons by tunneling systems. Above T c the phonon contribution to the thermal conductivity can be described successfully within a model considering not only electrons and phonons but also localized modes as scattering centres. To expand the accessible temperature range for experiments an adiabatic nuclear demagnetization refrigerator was set up. For measuring the base temperature a novel noise thermometer was developed which enables continuous measuring of the temperature in this temperature range for the first time. Therefore the magnetic Johnson noise of a massive copper cylinder is simultaneously monitored by two SQUID magnetometers. A subsequent cross-correlation suppresses the amplifier noise by more than one order of magnitude. The thermometer was characterized between 42μK and 0.8K showing no deviation from the expected linear behaviour between the power spectral density of the thermal noise and the temperature.

  1. 27 CFR 30.22 - Hydrometers and thermometers.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Hydrometers and... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS GAUGING MANUAL Gauging Instruments § 30.22 Hydrometers and thermometers. The hydrometers used are graduated to read the proof of aqueous alcoholic solutions at 60 degrees...

  2. On Johnson's Paradox: Hypothesis Verification

    Science.gov (United States)

    Noble, Clyde E.

    1975-01-01

    When H. M. Johnson argued that all inductive reasoning is based on the fallacy of affirming the consequent and cannot therefore establish the 'truth' of scientific hypotheses, he posed a paradox for strict empiricists. Author examined Johnson's argument. (Editor/RK)

  3. Cause elucidation of sodium leakage incident at `Monju` reactor. Vibration of thermometer due to fluid force

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Koji; Wada, Yusaku; Morishita, Masaki; Yamaguchi, Akira; Ichimiya, Masakazu [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-01-01

    This is a report of summarized results of investigation and analysis on fracture of thermometer which is direct reason of sodium leakage incident at the second main cooling system of fast breeder reactor `Monju`. Various surveys such as on various damage factors, on flowing power vibrational features containing flowing power vibrational test of thermometer, on evaluation of high cycle fatigue due to flowing power vibration and details on propagation of and fracture due to fatigue crack, on why only said thermometer damaged, and so forth were executed. As results of these examinations, a decision was arrived that high cycle fatigue due to vibration formed by fluid force (fluid force vibration) was a direct cause of the thermometer damage. (G.K.)

  4. Cryogenic thermometer calibration system using a helium cooling loop and a temperature controller [for LHC magnets

    CERN Document Server

    Chanzy, E; Thermeau, J P; Bühler, S; Joly, C; Casas-Cubillos, J; Balle, C

    1998-01-01

    The IPN-Orsay and CERN are designing in close collaboration a fully automated cryogenic thermometer calibration facility which will calibrate in 3 years 10,000 cryogenic thermometers required for the Large Hadron Collider (LHC) operation. A reduced-scale model of the calibration facility has been developed, which enables the calibration of ten thermometers by comparison with two rhodium-iron standard thermometers in the 1.8 K to 300 K temperature range under vacuum conditions. The particular design, based on a helium cooling loop and an electrical temperature controller, gives good dynamic performances. This paper describes the experimental set-up and the data acquisition system. Results of experimental runs are also presented along with the estimated global accuracy for the calibration. (3 refs).

  5. A quantum accurate waveform synthesizer as a voltage reference for an electronic primary thermometer

    Science.gov (United States)

    Pollarolo, Alessio; Benz, Samuel; Rogalla, Horst; Dresselhaus, Paul

    2014-03-01

    We are using a quantum voltage noise source (QVNS) for use as an intrinsically accurate voltage reference for a new type of electronic temperature standard. In Johnson Noise Thermometry (JNT) the noise of a resistor is used to measure temperature or Boltzmann's constant k, because the Nyquist equation =4kTR Δf shows that the power spectral density is proportional to k, temperature T, resistance R and measurement bandwidth Δf . The QVNS is a digital to analog converter used to synthesize a voltage waveform that resembles pseudo-random noise comparable in amplitude to the resistor noise. The signal generated is a frequency comb of harmonics tones that are equally spaced in frequency, all having identical amplitudes but random phases. The QVNS is an array superconducting Josephson junctions that are biased with a pulsed waveform clocked at 10 GHz. The accuracy of the voltage waveform derives from the identical voltage pulses produced by each junction that are perfectly quantized because their time-integrals are always equal to flux quantum h/2 e. The time-dependent output voltage waveform is determined by the number of pulses and their density in time. The measurement electronics exploits cross-correlation techniques to reduce the uncorrelated measurement noise so as to reveal the resistor noise, both of which are on the order of 2 nV/ √Hz. With this technique we have measured k with an uncertainty of about one part in 105, which we hope to improve by another order of magnitude with further research.

  6. New blackbody standard for the evaluation and calibration of tympanic ear thermometers at the NPL, United Kingdom

    Science.gov (United States)

    McEvoy, Helen C.; Simpson, Robert; Machin, Graham

    2004-04-01

    The use of infrared tympanic thermometers for monitoring patient health is widespread. However, studies into the performance of these thermometers have questioned their accuracy and repeatability. To give users confidence in these devices, and to provide credibility in the measurements, it is necessary for them to be tested using an accredited, standard blackbody source, with a calibration traceable to the International Temperature Scale of 1990 (ITS-90). To address this need the National Physical Laboratory (NPL), UK, has recently set up a primary ear thermometer calibration (PET-C) source for the evaluation and calibration of tympanic (ear) thermometers over the range from 15 °C to 45 °C. The overall uncertainty of the PET-C source is estimated to be +/- 0.04 °C at k = 2. The PET-C source meets the requirements of the European Standard EN 12470-5: 2003 Clinical thermometers. It consists of a high emissivity blackbody cavity immersed in a bath of stirred liquid. The temperature of the blackbody is determined using an ITS-90 calibrated platinum resistance thermometer inserted close to the rear of the cavity. The temperature stability and uniformity of the PET-C source was evaluated and its performance validated. This paper provides a description of the PET-C along with the results of the validation measurements. To further confirm the performance of the PET-C source it was compared to the standard ear thermometer calibration sources of the National Metrology Institute of Japan (NMIJ), Japan and the Physikalisch-Technische Bundesanstalt (PTB), Germany. The results of this comparison will also be briefly discussed. The PET-C source extends the capability for testing ear thermometers offered by the NPL body temperature fixed-point source, described previously. An update on the progress with the commercialisation of the fixed-point source will be given.

  7. Recent experience in health promotion at Johnson & Johnson: lower health spending, strong return on investment.

    Science.gov (United States)

    Henke, Rachel M; Goetzel, Ron Z; McHugh, Janice; Isaac, Fik

    2011-03-01

    Johnson & Johnson Family of Companies introduced its worksite health promotion program in 1979. The program evolved and is still in place after more than thirty years. We evaluated the program's effect on employees' health risks and health care costs for the period 2002-08. Measured against similar large companies, Johnson & Johnson experienced average annual growth in total medical spending that was 3.7 percentage points lower. Company employees benefited from meaningful reductions in rates of obesity, high blood pressure, high cholesterol, tobacco use, physical inactivity, and poor nutrition. Average annual per employee savings were $565 in 2009 dollars, producing a return on investment equal to a range of $1.88-$3.92 saved for every dollar spent on the program. Because the vast majority of US adults participate in the workforce, positive effects from similar programs could lead to better health and to savings for the nation as a whole.

  8. Calibration of Cryogenic Thermometers for the LHC

    CERN Document Server

    Balle, Ch; Vauthier, N; Thermeau, JP

    2008-01-01

    6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In the framework of a special contribution, IPN (Institut de Physique Nucléaire) in Orsay, France built and operated a calibration facility with a throughput of 80 thermometers per week. After reception from the manufacturer, the thermometer is first assembled onto a support specific to the measurement environment, and then thermally cycled ten times and calibrated at least once from 1.6 to 300 K. The procedure for each of these interventions includes various measurements and the acquired data is recorded in an ORACLE®-database. Furthermore random calibrations on some samples are executed at CERN to crosscheck the coherence between the approximation data obtained by both IPN and CERN. In the range of 1.5 K to 30 K...

  9. The electrical properties of a planar coil electromagnetic acoustic transducer and their implications for noise performance

    International Nuclear Information System (INIS)

    Seher, Matthias; Challis, Richard

    2016-01-01

    This paper is concerned with the electrical properties of an electromagnetic acoustic transducer (EMAT) formed of a flat spiral coil coupled to steel sheet components and operating over a narrow band of frequencies around 50 kHz, well below significant resonances. The electromagnetic skin effect is a significant contributor to the terminal impedance of the EMAT and hence to signal sensitivity, Johnson noise generation and the achievable signal-to-noise ratios (SNR). A transformer model is developed to simulate these effects and to assist in the optimization of the SNR. In this analysis Johnson noise in the system is compared to the unknown emf generated in the eddy current path by an incident acoustic wave to yield a fundamental SNR. The attainable SNR of the whole system is normalized to this in the form of a noise figure. (paper)

  10. Development and psychometric testing of a new tool for detecting moral distress: the Moral Distress Thermometer.

    Science.gov (United States)

    Wocial, Lucia D; Weaver, Michael T

    2013-01-01

    To report the development and psychometric testing of the Moral Distress Thermometer. The Moral Distress Thermometer is a new screening tool to measure moral distress in nurses who practise in the hospital setting. Moral distress occurs when one knows the ethically correct thing to do, but is prevented from acting on that perceived obligation. It is a well documented phenomenon with negative consequences that may be experienced by nurses. Creating an instrument to effectively and efficiently measure moral distress in a timely way has been identified as a priority for nursing. This study used a cross-sectional survey design. Data collection for this research occurred in 2009. Participants simultaneously completed either the adult or pediatric version of the Moral Distress Scale version 2009 and the Moral Distress Thermometer. A total of 529 participants from various clinical areas completed both tools. Coefficients alpha were adequate for both Adult (0·90) and Pediatric (0·92) Moral Distress Scale 2009 scales. Statistically significant Pearson correlations were found for the Moral Distress Thermometer with Adult Moral Distress Scale 2009 and Pediatric Moral Distress Scale 2009 and higher Moral Distress Thermometer, Adult Moral Distress Scale 2009 and Pediatric Moral Distress Scale 2009 means for participants who had left or who considered leaving a position because of moral distress. These findings provide support for the validity of the Moral Distress Thermometer. © 2012 Blackwell Publishing Ltd.

  11. Design and test of component circuits of an integrated quantum voltage noise source for Johnson noise thermometry

    International Nuclear Information System (INIS)

    Yamada, Takahiro; Maezawa, Masaaki; Urano, Chiharu

    2015-01-01

    Highlights: • We demonstrated RSFQ digital components of a new quantum voltage noise source. • A pseudo-random number generator and variable pulse number multiplier are designed. • Fabrication process is based on four Nb wiring layers and Nb/AlOx/Nb junctions. • The circuits successfully operated with wide dc bias current margins, 80–120%. - Abstract: We present design and testing of a pseudo-random number generator (PRNG) and a variable pulse number multiplier (VPNM) which are digital circuit subsystems in an integrated quantum voltage noise source for Jonson noise thermometry. Well-defined, calculable pseudo-random patterns of single flux quantum pulses are synthesized with the PRNG and multiplied digitally with the VPNM. The circuit implementation on rapid single flux quantum technology required practical circuit scales and bias currents, 279 junctions and 33 mA for the PRNG, and 1677 junctions and 218 mA for the VPNM. We confirmed the circuit operation with sufficiently wide margins, 80–120%, with respect to the designed bias currents.

  12. Design and test of component circuits of an integrated quantum voltage noise source for Johnson noise thermometry

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takahiro, E-mail: yamada-takahiro@aist.go.jp [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Maezawa, Masaaki [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Urano, Chiharu [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Central 3, Umezono 1-1-1, Tsukuba, Ibaraki 305-8563 (Japan)

    2015-11-15

    Highlights: • We demonstrated RSFQ digital components of a new quantum voltage noise source. • A pseudo-random number generator and variable pulse number multiplier are designed. • Fabrication process is based on four Nb wiring layers and Nb/AlOx/Nb junctions. • The circuits successfully operated with wide dc bias current margins, 80–120%. - Abstract: We present design and testing of a pseudo-random number generator (PRNG) and a variable pulse number multiplier (VPNM) which are digital circuit subsystems in an integrated quantum voltage noise source for Jonson noise thermometry. Well-defined, calculable pseudo-random patterns of single flux quantum pulses are synthesized with the PRNG and multiplied digitally with the VPNM. The circuit implementation on rapid single flux quantum technology required practical circuit scales and bias currents, 279 junctions and 33 mA for the PRNG, and 1677 junctions and 218 mA for the VPNM. We confirmed the circuit operation with sufficiently wide margins, 80–120%, with respect to the designed bias currents.

  13. Low-energy X-ray detection in cryogenic detectors with tungsten thermometers

    International Nuclear Information System (INIS)

    Colling, P.; Nucciotti, A.; Bucci, C.; Cooper, S.; Ferger, P.; Frank, M.; Nagel, U.; Proebst, F.; Seidel, W.

    1994-08-01

    In the course of our development of calorimetric particle detectors with superconducting phase transition thermometers, we have succeeded in depositing epitaxial α-tungsten films on sapphire which have critical temperatures T c near 15 mK. To our knowledge this is the first time that the T c of bulk tungsten has been observed in thin films. Such films used as thermometers are very sensitive and provide good energy resolution: with 4 g and 32 g sapphire crystals energy resolutions of better than 100eV (FWHM) for 1.5 KeV X-rays have been achieved. (orig.)

  14. Very high temperature ultrasonic thermometer

    International Nuclear Information System (INIS)

    Jorzik, E.

    1983-01-01

    An ultrasonic thermometer comprises an electric pulse transducer head, a pulse transmission line, a notched sensor wire attached to and extending along the axis of said transmission line and a sheath enclosing the transmission line and the sensor wire, a portion of the interior face of the sheath being covered by a stuffing material along at least the length of the notched part of the sensor wire, such that contact between the sensor wire and the stuffing material does not substantially give rise to reflection of an ultrasonic pulse at the point of contact. (author)

  15. Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky

    Science.gov (United States)

    Mims, Forrest M., III; Chambers, Lin H.; Brooks, David R.

    2011-01-01

    A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.

  16. Model for cryogenic particle detectors with superconducting phase transition thermometers

    International Nuclear Information System (INIS)

    Proebst, F.; Frank, M.; Cooper, S.; Colling, P.; Dummer, D.; Ferger, P.; Nucciotti, A.; Seidel, W.; Stodolsky, L.

    1994-09-01

    We present data on a detector composed of an 18 g Si crystal and a superconducting phase transition thermometer which could be operated over a wide temperature range. An energy resolution of 1 keV (FWHM) has been obtained for 60 keV photons. The signals consist of two components: A fast one and a slow one, with decay times of 1.5 ms and 30-60 ms, respectively. In this paper we present a simple model which takes thermal and non-thermal phonon processes into account and provides a description of the observed temperature dependence of the pulse shape. The fast component, which completely dominates the signal at low temperatures, is due to high-frequency non-thermal phonons being absorbed in the thermometer. Thermalization of these phonons then leads to a temperature rise of the absorber, which causes the slow thermal component. At the highest operating temperatures (T∼80 mK) the amplitude of the slow component is roughly as expected from the heat capacity of the absorber. The strong suppression of the slow component at low temperatures is explained mostly as a consequence of the weak thermal coupling between electrons and phonons in the thermometer at low temperatures. (orig.)

  17. Design and test of component circuits of an integrated quantum voltage noise source for Johnson noise thermometry

    Science.gov (United States)

    Yamada, Takahiro; Maezawa, Masaaki; Urano, Chiharu

    2015-11-01

    We present design and testing of a pseudo-random number generator (PRNG) and a variable pulse number multiplier (VPNM) which are digital circuit subsystems in an integrated quantum voltage noise source for Jonson noise thermometry. Well-defined, calculable pseudo-random patterns of single flux quantum pulses are synthesized with the PRNG and multiplied digitally with the VPNM. The circuit implementation on rapid single flux quantum technology required practical circuit scales and bias currents, 279 junctions and 33 mA for the PRNG, and 1677 junctions and 218 mA for the VPNM. We confirmed the circuit operation with sufficiently wide margins, 80-120%, with respect to the designed bias currents.

  18. A Fluorescent Thermometer Based on a Pyrene-Labeled Thermoresponsive Polymer

    Directory of Open Access Journals (Sweden)

    Ulrich S. Schubert

    2010-08-01

    Full Text Available Thermoresponsive polymers that undergo a solubility transition by variation of the temperature are important materials for the development of ‘smart’ materials. In this contribution we exploit the solubility phase transition of poly(methoxy diethylene glycol methacrylate, which is accompanied by a transition from hydrophilic to hydrophobic, for the development of a fluorescent thermometer. To translate the polymer phase transition into a fluorescent response, the polymer was functionalized with pyrene resulting in a change of the emission based on the microenvironment. This approach led to a soluble polymeric fluorescent thermometer with a temperature range from 11 °C to 21 °C. The polymer phase transition that occurs during sensing is studied in detail by dynamic light scattering.

  19. A Phase-Locked Loop Continuous Wave Sonic Anemometer-Thermometer

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Weller, F. W.; Busings, J. A.

    1979-01-01

    A continuous wake sonic anemometer-thermometer has been developed for simultaneous measurements of vertical velocity and temperature. The phase angle fluctuations are detected by means of a monolithic integrated phase-locked loop, the latter feature providing for inexpensive and accurate...

  20. Johnson(-like)-Noise-Kirchhoff-loop based secure classical communicator characteristics, for ranges of two to two thousand kilometers, via model-line

    International Nuclear Information System (INIS)

    Mingesz, Robert; Gingl, Zoltan; Kish, Laszlo B.

    2008-01-01

    A pair of Kirchhoff-loop-Johnson(-like)-Noise communicators, which is able to work over variable ranges, was designed and built. Tests have been carried out on a model-line performance characteristics were obtained for ranges beyond the ranges of any known direct quantum communication channel and they indicate unrivalled signal fidelity and security performance of the exchanged raw key bits. This simple device has single-wire secure key generation and sharing rates of 0.1, 1, 10, and 100 bit/second for corresponding copper wire diameters/ranges of 21 mm/2000 km, 7 mm/200 km, 2.3 mm/20 km, and 0.7 mm/2 km, respectively and it performs with 0.02% raw-bit error rate (99.98% fidelity). The raw-bit security of this practical system significantly outperforms raw-bit quantum security. Current injection breaking tests show zero bit eavesdropping ability without triggering the alarm signal, therefore no multiple measurements are needed to build an error statistics to detect the eavesdropping as in quantum communication. Wire resistance based breaking tests of Bergou-Scheuer-Yariv type give an upper limit of eavesdropped raw-bit ratio of 0.19% and this limit is inversely proportional to the sixth power of cable diameter. Hao's breaking method yields zero (below measurement resolution) eavesdropping information

  1. Reef coral δ18O thermometer in Hainan island waters, south China sea

    International Nuclear Information System (INIS)

    He Xuexian; Peng Zicheng; Wang Zhaorong; Huo Weiguo; Tan Jun; Nie Baofu; Chen Tegu; Zhong Jinliang

    2000-01-01

    An 18-year-long (1981-1998) study was conducted in Hainan Island waters (22 degree 22'N, 110 degree 39'E) to determine the relationship between δ 18 O in skeletal aragonite carbonate and sea surface temperature (SST) in porites lutea of reef-building corals. δ 18 O values in skeletal aragonite carbonate were measured by means of mass spectrometry. Coral samples grew at 5 m depth at Longwan Bay. Monthly measurements of the SST from 1960 to 1998 were taken at Qinglan Bay adjacent to the place of the collected samples. The thermometer shows that SST = -4.16 δ 18 O PDB + 4.9 (r = 0.80) and dδ 18 O/dT = -0.24 per mil/degree C. The δ 18 O thermometer is strongly influenced by the rainfall and runoff. Using the thermometer, the SST in the past hundred years with monthly resolution will be reconstructed and the climatic change in the northern area of South China Sea will be hind cast

  2. Cryogenic particle detectors with superconducting phase transition thermometers

    International Nuclear Information System (INIS)

    Ferger, P.; Colling, P.; Bucci, C.; Nucciotti, A.; Buehler, M.; Cooper, S.; Feilitzsch, F. v.; Forster, G.; Gabutti, A.; Hoehne, J.; Igalson, J.; Kellner, E.; Loidl, M.; Meier, O.; Nagel, U.; Proebst, F.; Rulofs, A.; Schanda, U.; Seidel, W.; Sisti, M.; Stodolsky, L.; Stolovich, A.; Zerle, L.

    1996-01-01

    A tungsten superconducting phase transition thermometer on a 32 g sapphire crystal has given an energy resolution of 100 eV (FWHM) for 1.5 keV X-rays, increasing to 440 eV at 14 keV. A possibility to obtain similar resolution in much larger crystals by using Al films as phonon collectors is presented. (orig.)

  3. Functional summary statistics for the Johnson-Mehl model

    DEFF Research Database (Denmark)

    Møller, Jesper; Ghorbani, Mohammad

    The Johnson-Mehl germination-growth model is a spatio-temporal point process model which among other things have been used for the description of neurotransmitters datasets. However, for such datasets parametric Johnson-Mehl models fitted by maximum likelihood have yet not been evaluated by means...... of functional summary statistics. This paper therefore invents four functional summary statistics adapted to the Johnson-Mehl model, with two of them based on the second-order properties and the other two on the nuclei-boundary distances for the associated Johnson-Mehl tessellation. The functional summary...... statistics theoretical properties are investigated, non-parametric estimators are suggested, and their usefulness for model checking is examined in a simulation study. The functional summary statistics are also used for checking fitted parametric Johnson-Mehl models for a neurotransmitters dataset....

  4. History and Evolution of the Johnson Criteria.

    Energy Technology Data Exchange (ETDEWEB)

    Sjaardema, Tracy A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Smith, Collin S. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Birch, Gabriel Carisle [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    The Johnson Criteria metric calculates probability of detection of an object imaged by an optical system, and was created in 1958 by John Johnson. As understanding of target detection has improved, detection models have evolved to better model additional factors such as weather, scene content, and object placement. The initial Johnson Criteria, while sufficient for technology and understanding at the time, does not accurately reflect current research into target acquisition and technology. Even though current research shows a dependence on human factors, there appears to be a lack of testing and modeling of human variability.

  5. Study on the KM capacitor base thermometers in the 42-273 K range

    International Nuclear Information System (INIS)

    Luzganov, V.S.; Mats'ko, A.A.

    1988-01-01

    Thermometric characteristics of the KM-5a-HZ0 monolithic capacitors in the 42-273 K temperature range are studied. Capacitors capacitance - temperature relation is considered in details. The data reproducibility after 5, 23, 34, 50, 51 and 57 days is studied, the accuracy of temperature measurements by the given thermometers is determined. Recommendations on selection of cpacitors, suitable for application as thermometer, are given. These capacitors permit temperature measurement in the 42-225 K range with the error of ± 0.5 K, and above 225 K the error is ± 1K. 8 refs.; 1 fig.; 1 tab

  6. Hydrology of the Johnson Creek Basin, Oregon

    Science.gov (United States)

    Lee, Karl K.; Snyder, Daniel T.

    2009-01-01

    The Johnson Creek basin is an important resource in the Portland, Oregon, metropolitan area. Johnson Creek forms a wildlife and recreational corridor through densely populated areas of the cities of Milwaukie, Portland, and Gresham, and rural and agricultural areas of Multnomah and Clackamas Counties. The basin has changed as a result of agricultural and urban development, stream channelization, and construction of roads, drains, and other features characteristic of human occupation. Flooding of Johnson Creek is a concern for the public and for water management officials. The interaction of the groundwater and surface-water systems in the Johnson Creek basin also is important. The occurrence of flooding from high groundwater discharge and from a rising water table prompted this study. As the Portland metropolitan area continues to grow, human-induced effects on streams in the Johnson Creek basin will continue. This report provides information on the groundwater and surface-water systems over a range of hydrologic conditions, as well as the interaction these of systems, and will aid in management of water resources in the area. High and low flows of Crystal Springs Creek, a tributary to Johnson Creek, were explained by streamflow and groundwater levels collected for this study, and results from previous studies. High flows of Crystal Springs Creek began in summer 1996, and did not diminish until 2000. Low streamflow of Crystal Springs Creek occurred in 2005. Flow of Crystal Springs Creek related to water-level fluctuations in a nearby well, enabling prediction of streamflow based on groundwater level. Holgate Lake is an ephemeral lake in Southeast Portland that has inundated residential areas several times since the 1940s. The water-surface elevation of the lake closely tracked the elevation of the water table in a nearby well, indicating that the occurrence of the lake is an expression of the water table. Antecedent conditions of the groundwater level and autumn

  7. Genetically encoded ratiometric fluorescent thermometer with wide range and rapid response.

    Directory of Open Access Journals (Sweden)

    Masahiro Nakano

    Full Text Available Temperature is a fundamental physical parameter that plays an important role in biological reactions and events. Although thermometers developed previously have been used to investigate several important phenomena, such as heterogeneous temperature distribution in a single living cell and heat generation in mitochondria, the development of a thermometer with a sensitivity over a wide temperature range and rapid response is still desired to quantify temperature change in not only homeotherms but also poikilotherms from the cellular level to in vivo. To overcome the weaknesses of the conventional thermometers, such as a limitation of applicable species and a low temporal resolution, owing to the narrow temperature range of sensitivity and the thermometry method, respectively, we developed a genetically encoded ratiometric fluorescent temperature indicator, gTEMP, by using two fluorescent proteins with different temperature sensitivities. Our thermometric method enabled a fast tracking of the temperature change with a time resolution of 50 ms. We used this method to observe the spatiotemporal temperature change between the cytoplasm and nucleus in cells, and quantified thermogenesis from the mitochondria matrix in a single living cell after stimulation with carbonyl cyanide 4-(trifluoromethoxyphenylhydrazone, which was an uncoupler of oxidative phosphorylation. Moreover, exploiting the wide temperature range of sensitivity from 5°C to 50°C of gTEMP, we monitored the temperature in a living medaka embryo for 15 hours and showed the feasibility of in vivo thermometry in various living species.

  8. Patronage power: Rural electrification, river development, and Lyndon Johnson (1937--1939)

    Science.gov (United States)

    Dusek, Paul-Michael Mays

    Few historians document Lyndon Johnson's efforts to construct a state-wide political machine at the local level early in his congressional career. The literature glorifies Johnson for hydroelectric river development and rural electrification. This thesis acknowledges the transformative nature of rural electrification in Central Texas through the efforts of Johnson but, more importantly, reveals how extensively Johnson sought to capitalize on the tail-end of the New Deal to utilize government-funded relief projects to establish a state-wide political machine. An analysis of the correspondence between Johnson, his local political operators, members of his state-wide network, and rural constituents reveals another layer to the complexity of Johnson and further exposes his ambitious, calculating nature. Johnson used rural electrification to first create a community of supporters in his congressional district then used rural electrification and multipurpose river development programs to cultivate political contacts across the state of Texas. This thesis explores the first time that Lyndon Johnson used patronage to develop a political community as a publicly elected official. Johnson pushed for constant expansion of operations to ensure a steady supply of new jobs while displaying a cavalier attitude about specific regulations regarding the allocation of funds. His machine manipulated and massaged congressional appropriations restrictions and utilized multiple congressional revenue streams to stretch finances further and lower overhead costs to increase the scope of operations thus further improving the lives of his constituents. Johnson also used this movement to efficiently and effectively construct a foundation for his political machine. This thesis also clarifies an early moment in Johnson's beliefs about civil rights. Instead of standing on principle, Johnson relied on extortion and threats to fight racism at this early juncture in his political career because of

  9. Evaluation of a Teaching Kit for Family and Consumer Science Classrooms: Motivating Students to Use a Food Thermometer with Small Cuts of Meat

    Science.gov (United States)

    Edwards, Zena; Edlefsen, Miriam; Hillers, Virginia; McCurdy, Sandra M.

    2005-01-01

    The U.S. Dept. of Agriculture recommends use of food thermometers to safely cook small cuts of meat, yet most consumers do not use them. Consumers lack knowledge about how and why to use food thermometers with small cuts of meat. Opportunities exist for family and consumer science classes to provide education about thermometers to adolescents, who…

  10. Stevens-Johnson syndrome after radiotherapy

    International Nuclear Information System (INIS)

    Howell, W.R.; Knight, A.L.; Scruggs, H.J.

    1990-01-01

    We have reported a case of classic Stevens-Johnson syndrome in association with treatment using a cobalt radiation therapy unit. Previous reports of such an association have been extremely rare. At the time of the reaction, the patient's only medications were methyldopa and trichlormethiazide. Other drugs in the thiazide class have been associated with such a reaction. We feel this is an unlikely association in our patient, however, because she had been on trichlormethiazide for a number of years. This report suggests the role of radiotherapy as a rare cause of Stevens-Johnson syndrome. 14 references

  11. Preliminary Results on New Prototypes of Precision Rh-0.5at%Fe Resistance Thermometers of Chinese Production

    Science.gov (United States)

    Pavese, F.; Szmyrka-Grzebyk, A.; Lipinski, L.; Manuszkiewicz, H.; Qiu, Ping; Zhang, Jin Tao; Lin, Peng; Li, Xing Wei

    2008-02-01

    Given the practical impossibility of obtaining new precision Rh-0.5at%Fe resistance thermometers in recent years, the possible re-starting of the production of such thermometers in Yunnan (China) was explored by Istituto Nazionale di Ricerca Metrologica (INRIM). Ten prototypes of the new production were made available in early 2006. The paper reports the preliminary data from the testing performed to date on these prototypes at National Institute of Metrology (NIM) and Instytut Niskich Temperatur i Badan Strukturalnych (INTiBS). Although a problem with the alloy composition was detected, the reproducibility results on thermal cycling are very encouraging. Resistance-temperature ( R- T) characteristics below 30 K, though not identical with those of similar thermometers formerly available from Tinsley and VNIIFTRI, are still suitable for accurate metrology.

  12. A gas thermometer for vapor pressure measurements

    Science.gov (United States)

    Rusin, A. D.

    2008-08-01

    The pressure of an inert gas over the range 400 1000 K was measured on a tensimetric unit with a quartz membrane pressure gauge of enhanced sensitivity. It was shown that a reactor with a membrane null gauge could be used as a gas thermometer. The experimental confidence pressure and temperature intervals were 0.07 torr and 0.1 K at a significance level of 0.05. A Pt-Pt/10% Rh thermocouple was calibrated; the results were approximated by a polynomial of degree five. The error in temperature calculations was 0.25 K.

  13. Ultrasensitive thermometer for atmospheric pressure operation based on a micromechanical resonator

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Pini, V.; Tamayo, J.

    2014-01-01

    For highly integrated systems for bio and chemical analysis a precise and integrated measurement of temperature is of fundamental importance. We have developed an ultrasensitive thermometer based on a micromechanical resonator for operation in air. The high quality factor and the strong temperatu...

  14. Johnsons Seagrass Critical Habitat

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data represent the critical habitat for Johnson's Seagrass as designated by Federal Register Vol. 65, No. 66, Wednesday, April 5, 2000, Rules and Regulations.

  15. Corporate social responsibility in public health: A case-study on HIV/AIDS epidemic by Johnson & Johnson company in Africa

    Science.gov (United States)

    Chattu, Vijay Kumar

    2015-01-01

    HIV/AIDS has claimed millions of lives in the global workforce and continues to remain a threat to many businesses. An estimated 36.5 million of working people are living with HIV; the global workforce has lost 28 million people from AIDS since the beginning of the epidemic. In the absence of access to treatment, this number could grow to 74 million by 2015. The epidemic continues to affect the working population through absenteeism, sickness and death. Corporate Social Responsibility (CSR) is an obligation that corporates have toward their employees, community and society. A review and documentation of one such CSR by Johnson & Johnson (a multinational company) for HIV/AIDS in Africa is presented here. Johnson & Johnson Company is involved in numerous projects around the world to combat the HIV/AIDS epidemic. The company is working to fight the spread of the disease and improve the quality of life for those living with the illness through various donations of its products and sponsorship of local programs. This case study also highlights different categories of CSR activities such as Cause Promotion, Cause related Marketing, Corporate Philanthropy, Corporate Social Marketing, Corporate Volunteering and Socially responsible business practices, which are discussed with specific examples from different countries in Africa. Conclusions: CSR of any business encompasses the economic, legal, ethical & discretionary expectation placed on the organization by society at a given point of time. CSR is therefore the obligation that corporations have toward their stakeholders and society in general which horizons beyond what is prescribed by law or union contracts. Johnson & Johnson has a proved history of being committed to caring for people and a good example of a company with a long history of citizenship and sustainability. PMID:25810667

  16. Corporate social responsibility in public health: A case-study on HIV/AIDS epidemic by Johnson & Johnson company in Africa.

    Science.gov (United States)

    Chattu, Vijay Kumar

    2015-01-01

    HIV/AIDS has claimed millions of lives in the global workforce and continues to remain a threat to many businesses. An estimated 36.5 million of working people are living with HIV; the global workforce has lost 28 million people from AIDS since the beginning of the epidemic. In the absence of access to treatment, this number could grow to 74 million by 2015. The epidemic continues to affect the working population through absenteeism, sickness and death. Corporate Social Responsibility (CSR) is an obligation that corporates have toward their employees, community and society. A review and documentation of one such CSR by Johnson & Johnson (a multinational company) for HIV/AIDS in Africa is presented here. Johnson & Johnson Company is involved in numerous projects around the world to combat the HIV/AIDS epidemic. The company is working to fight the spread of the disease and improve the quality of life for those living with the illness through various donations of its products and sponsorship of local programs. This case study also highlights different categories of CSR activities such as Cause Promotion, Cause related Marketing, Corporate Philanthropy, Corporate Social Marketing, Corporate Volunteering and Socially responsible business practices, which are discussed with specific examples from different countries in Africa. CSR of any business encompasses the economic, legal, ethical & discretionary expectation placed on the organization by society at a given point of time. CSR is therefore the obligation that corporations have toward their stakeholders and society in general which horizons beyond what is prescribed by law or union contracts. Johnson & Johnson has a proved history of being committed to caring for people and a good example of a company with a long history of citizenship and sustainability.

  17. Thermodynamics and historical relevance of a jetting thermometer made of Chinese zisha ceramic

    Science.gov (United States)

    Lee, Vincent; Attinger, Daniel

    2016-07-01

    Following a recent trend of scientific studies on artwork, we study here the thermodynamics of a thermometer made of zisha ceramic, related to the Chinese tea culture. The thermometer represents a boy who “urinates” shortly after hot water is poured onto his head. Long jetting distance is said to indicate that the water temperature is hot enough to brew tea. Here, a thermodynamic model describes the jetting phenomenon of that pee-pee boy. The study demonstrates how thermal expansion of an interior air pocket causes jetting. A thermodynamic potential is shown to define maximum jetting velocity. Seven optimization criteria to maximize jetting distance are provided, including two dimensionless numbers. Predicted jetting distances, jet durations, and temperatures agree very well with infrared and optical measurements. Specifically, the study confirms that jetting distances are sensitive enough to measure water temperature in the context of tea brewing. Optimization results show that longer jets are produced by large individuals, with low body mass index, with a boyhood of medium size inclined at an angle π/4. The study ends by considering the possibility that ceramic jetting artifacts like the pee-pee boy might have been the first thermometers known to mankind, before Galileo Galilei’s thermoscope.

  18. Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert

    Science.gov (United States)

    Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.

    2001-01-01

    Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers can be corrupted by emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.

  19. Use of infrared radiation thermometers for temperature control of plastic and paper webs in electric infrared ovens

    International Nuclear Information System (INIS)

    Jacobson, D.A.

    1985-01-01

    Using infrared radiation thermometers in conjunction with infrared heater systems requires special considerations to ensure that accuracy will be achieved. If the thermometer picks up infrared radiation from the heaters, faulty readings can occur. Two methods are generally employed to eliminate this interference. Sight tubes are used to block infrared rays from entering the sensor lens, and a thermometer is chosen which responds to a different wavelength than that being emitted from the infrared heaters. The main types of electric infrared heaters are: (a) screw-in bulbs (shortwave); (b) evacuated tungsten filament tubes (shortwave); (c) quartz tubes (medium wave); (d) quartz panel heaters (medium wave); (e) Ceramic heaters (medium-long wave); (f) metal sheath heaters (medium-long wave). Positioning of a sensor on a production line is dictated by the product being processed and the desired use of the temperature information. The most common location for a sensor is just after the infrared unit. The pyrometer information can be used for setting up the process, for quality control, for heater failure detection, and for control of the heaters. For wide web application in which uniformity across the web is essential, traversing sensors can be used to scan the web to ensure a uniform heating of the product. This information then can be used to control infrared profiling zones which are positioned across the web. In plastics applications, the thermometer most commonly is positioned also at the exit end of the infrared unit. Control functions are similar to those just listed. In some indexing machines, the plastic is sensed while still in the last index station, and the index an be initiated by the thermometer

  20. Mendie, Patrick Johnson

    African Journals Online (AJOL)

    Mendie, Patrick Johnson. Vol 15, No 2 (2015) - Articles An examination of the nexus between Thomas Hobbes‟ concept of human nature and theory of the state. Abstract. ISSN: 1119-443X. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  1. Current noise in tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Frey, Moritz; Grabert, Hermann [Physikalisches Institut, Universitaet Freiburg, Hermann-Herder-Strasse 3, 79104, Freiburg (Germany)

    2017-06-15

    We study current fluctuations in tunnel junctions driven by a voltage source. The voltage is applied to the tunneling element via an impedance providing an electromagnetic environment of the junction. We use circuit theory to relate the fluctuations of the current flowing in the leads of the junction with the voltage fluctuations generated by the environmental impedance and the fluctuations of the tunneling current. The spectrum of current fluctuations is found to consist of three parts: a term arising from the environmental Johnson-Nyquist noise, a term due to the shot noise of the tunneling current and a third term describing the cross-correlation between these two noise sources. Our phenomenological theory reproduces previous results based on the Hamiltonian model for the dynamical Coulomb blockade and provides a simple understanding of the current fluctuation spectrum in terms of circuit theory and properties of the average current. Specific results are given for a tunnel junction driven through a resonator. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. The free electron gas primary thermometer using an ordinary bipolar junction transistor approaches ppm accuracy

    Science.gov (United States)

    Mimila-Arroyo, J.

    2017-06-01

    In this paper, it is demonstrated that the free electron gas primary thermometer based on a bipolar junction transistor is able to provide the temperature with an accuracy of a few parts per million. Its simple functioning principle exploits the behavior of the collector current when properly biased to extract the temperature. Using general purpose silicon transistors at the water triple point (273.16 K) and gallium melting point (302.9146), an accuracy of a few parts per million has been reached, constituting the simplest and the easiest to operate primary thermometer, that might be considered even for the redefinition of Kelvin.

  3. Cefepime Associated With Phenytoin Induced Stevens-Johnson Syndrome.

    Science.gov (United States)

    Marco-Del Río, José; Domingo-Chiva, Esther; Cuesta-Montero, Pablo; Valladolid-Walsh, Ana; García-Martínez, Eva María

    We describe a recent case of Stevens-Johnson Syndrome. A 49-year-old man was admitted to the Intensive Care Unit of an Anaesthesia and Resuscitation Department because of a Fournier gangrene that derived in a sepsis, ventilator-associated pneumonia, and renal failure. He was under treatment with cefepime and suffered a generalized status epilepticus, so started treatment with phenytoin. The next day he developed a "maculous cutaneous eruption in trunk and lower limbs" compatible with a Stevens-Johnson Syndrome. Stevens-Johnson Syndrome is a very severe and potentially fatal multiorganic disease, especially when present in critically ill patients, with a strong drug-related etiology, especially with antiepileptic drugs.

  4. Johnson Creek Artificial Propagation and Enhancement Project Operations and Maintenance Program; Brood Year 1998: Johnson Creek Chinook Salmon Supplementation, Biennial Report 1998-2000.

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Mitch; Gebhards, John

    2003-05-01

    The Nez Perce Tribe, through funding provided by the Bonneville Power Administration, has implemented a small scale chinook salmon supplementation program on Johnson Creek, a tributary in the South Fork of the Salmon River, Idaho. The Johnson Creek Artificial Propagation Enhancement project was established to enhance the number of threatened Snake River summer chinook salmon (Oncorhynchus tshawytscha) returning to Johnson Creek through artificial propagation. Adult chinook salmon collection and spawning began in 1998. A total of 114 fish were collected from Johnson Creek and 54 fish (20 males and 34 females) were retained for Broodstock. All broodstock were transported to Lower Snake River Compensation Plan's South Fork Salmon River adult holding and spawning facility, operated by the Idaho Department of Fish and Game. The remaining 60 fish were released to spawn naturally. An estimated 155,870 eggs from Johnson Creek chinook spawned at the South Fork Salmon River facility were transported to the McCall Fish Hatchery for rearing. Average fecundity for Johnson Creek females was 4,871. Approximately 20,500 eggs from females with high levels of Bacterial Kidney Disease were culled. This, combined with green-egg to eyed-egg survival of 62%, resulted in about 84,000 eyed eggs produced in 1998. Resulting juveniles were reared indoors at the McCall Fish Hatchery in 1999. All of these fish were marked with Coded Wire Tags and Visual Implant Elastomer tags and 8,043 were also PIT tagged. A total of 78,950 smolts were transported from the McCall Fish Hatchery and released directly into Johnson Creek on March 27, 28, 29, and 30, 2000.

  5. Response of itchgrass and johnson grass to asulam/dalapon combinations

    International Nuclear Information System (INIS)

    Hook, B.J.

    1986-01-01

    Activities of asumlam [methyl[(4-aminophenyl)sulfonyl]carbamate], dalapon (2,2-dichloropropionic acid) and asulam/dalapon combinations on itchgrass (Rottboellia exaltata L.f.) and johnson grass [Sorghum halepense (L.) Pers.] were examined. When metabolism of 14 C-asulam was monitored, seven days after application, 97-100% of recovered 14 C co-chromatographed with 14 C-asulam. Itchgrass exhibited rapid uptake of 14 C-asulam within 8 hr after application. Asumlam concentrations remained constant in the plant between 8 and 72 hr. Johnson grass plants showed a differential response to asulam and asulam/dalapon treatments. Asulam-treated johnson grass absorbed 26-34% 14 C within 2 hr with no future significant increase in absorption in absorption through 72 hr. Treatment of johnson grass with asulam/dalapon enhanced 14 C absorption with time. At 24 and 72 hr 14 C levels were double that absorbed from treatment of asulam alone. Movement of 14 C-asulam in the apoplast and symplast of both itchgrass and johnson grass was noted. The highest radiolabel accumulated in the lower leaves of itchgrass and remained in the treated leaf of johnson grass

  6. A High-Resolution Thermometer for the Range 0.75-1.0 K

    Science.gov (United States)

    Panek, J.; Nash, A.; Larson, M.; Mulders, N.

    1999-01-01

    We report on a new high-resolution thermometer (HRT) for use near the tricritical point in 3He-4He mixtures. It is based on an existing HRT design that uses a DC-SQUID to detect the magnetization of a paramagnetic sensing element.

  7. Application of kinetic inductance thermometers to x-ray calorimetry

    International Nuclear Information System (INIS)

    Wai, Y.C.; Labov, S.E.; Silver, E.H.

    1990-01-01

    A kinetic inductance thermometer is applied to x-ray calorimetry, and its operation over a wide range of frequencies and geometries is discussed. Three amplifier configurations are described, one using a superconducting quantum interference device (SQUID) amplifier, another incorporating an FET amplifier in an amplitude modulated system, and the third, using a tunnel diode frequency modulated oscillator circuit. The predicted performance of each configuration is presented. 13 refs., 6 figs., 1 tab

  8. Environmental Physiology at the Johnson Space Center: Past, Present, and Future

    Science.gov (United States)

    Conkin, Johnny

    2007-01-01

    This viewgraph presentation reviews the work in environmental physiology done at Johnson Space Center (JSC). The work is aimed at keeping astronauts healthy. This is a different approach than treating the sick, and is more of an occupational health model. The reduction of risks is the main emphasis for this work. They emphasis is to reduce the risk of decompression sickness (DCS) and acute mountain sickness (AMS). The work in environmental physiology encompasses the following areas: (1) Pressure: hypobaric and hyperbaric (2) Gases: hypoxia and hyperoxia, hypercapnia--closed space issues, inert gas physiology / respiration (3) Temperature: hypothermia and hyperthermia, thermal comfort, Protective clothing diving, aviation, mountaineering, and space (4) Acceleration (5) Noise and Vibration (6) Exercise / Performance (6) Acclimatization / Adaptation: engineering solutions when necessary. This presentation reviews the work done at JSC in the areas of DCS and AMS.

  9. Optical Fiber Thermometer Based on Fiber Bragg Gratings

    Science.gov (United States)

    Rosli, Ekbal Bin; Mohd. Noor, Uzer

    2018-03-01

    Fiber Bragg grating has generated much interest in use as sensors to measure strain, temperature, and other physical parameters. It also the most common component used to develop this sensor with the advantages of simple, intrinsic sensing elements, electrically passive operation, EMI immunity, high sensitivity, compact size and potentially low cost [6]. This paper reports the design of an optical fiber thermometer based on fiber Bragg gratings. The system was developed for detecting temperature and strain by monitoring the shift of Bragg wavelength. The shifting of Bragg wavelength is used to indicate the temperature and strain due to the change in the surrounding temperature and strain. When the temperature and strain reach the exact wavelength level of the system, the temperature and strain value will display on the Arduino liquid crystal display (LCD). The optical fiber will provide the broadband light source and after passing the FBG the Bragg wavelength into the optical spectrum analyzer (OSA). The system is based on FBG as a physical quantity sensor. The temperatures measured is taken from the water bath and that of the strain is provided by amount of slotted mass used. The outcome of this project is to characterize the Bragg wavelength shifting from the fiber Bragg grating output. As the conclusion, this project provides an efficient optical fiber thermometer in measuring temperature and strain in order to replace the use of conventional electrical instruments.

  10. Johnson syndrome in a Nigerian woman with chronic lymphocytic ...

    African Journals Online (AJOL)

    Stevens-Johnson syndrome is an adverse muco-cutaneous complication arising from a number of conditions which include the administration of some drugs. A female Nigerian with chronic lymphocytic leukaemia, (Binet stage C) who developed Stevens-Johnson syndrome following commencement of allopurinol is ...

  11. Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study

    Directory of Open Access Journals (Sweden)

    Smith Linda S

    2003-06-01

    Full Text Available Abstract Background As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1 to examine age, race, site as variables affecting temperature measurement in adults, and 2 to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. Methods Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120 of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F measured at oral, skin (simultaneous, immediately followed by rectal sites with four each mercury-glass (BD and Galinstan-glass (Geratherm thermometers; 10 minute dwell times. Results Participants averaged 61.6 years (SD 17.9, 188 pounds (SD 55.3; 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F: oral (0.142 – 0.265, axilla (0.167 – 0.339, groin (0.037 – 0.321, and rectal (-0.111 – 0.111. Race correlated with age, temperature readings each site and device. Conclusion Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered

  12. Lyndon B. Johnson and the Civil Right Act of 1964

    Directory of Open Access Journals (Sweden)

    Karatzas Konstantinos D.

    2016-09-01

    Full Text Available The Civil Rights Movement is deeply intertwined with Lyndon B. Johnson. Throughout his career, Johnson supported the quest of African-Americans for political and civil rights. They found in him an ally whose role was fundamental in fullfilling the goals of Martin Luther King, Jr, and the Civil Rights Movement. This paper will examine the role of the Johnson presidency in the passage of the Civil Rights Acts of 1957 and 1964.

  13. An investigation of excess noise in transition-edge sensors on a solid silicon substrate

    International Nuclear Information System (INIS)

    Crowder, S.G.; Lindeman, M.A.; Anderson, M.B.; Bandler, S.R.; Bilgri, N.; Bruijn, M.P.; Chervenak, J.; Figueroa-Feliciano, E.; Finkbeiner, F.; Germeau, A.; Hoevers, H.F.C.; Iyomoto, N.; Kelly, R.; Kilbourne, C.A.; Lai, T.; Man, J.; McCammon, D.; Nelms, K.L.; Porter, F.S.; Rocks, L.; Saab, T.; Sadleir, J.; Vidugiris, G.

    2006-01-01

    Transition-edge sensors (TESs) exhibit two major types of excess noise above the expected and unavoidable thermodynamic fluctuation noise (TFN) to the heat sink and Johnson noise. High-resistance TESs such as those made by the Netherlands Institute for Space Research (SRON) show excess noise consistent with internal TFN (ITFN) caused by random energy transport within the TES itself while low resistance TESs show an excess voltage noise of unknown origin seemingly unrelated to temperature fluctuations. Running a high-resistance TES on a high thermal conductivity substrate should suppress ITFN and allow detection of any excess voltage noise. We tested two TESs on a solid silicon substrate fabricated by SRON of a relatively high normal state resistance of ∼200 mΩ. After determining a linear model of the TES response to noise for the devices, we found little excess TFN and little excess voltage noise for bias currents of up to ∼20 μA

  14. Assessing the accuracy of globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate

    Science.gov (United States)

    Khrit, N. G.; Alghoul, M. A.; Sopian, K.; Lahimer, A. A.; Elayeb, O. K.

    2017-11-01

    Assessing outdoor human thermal comfort and urban climate quality require experimental investigation of microclimatic conditions and their variations in open urban spaces. For this, it is essential to provide quantitative information on air temperature, humidity, wind velocity and mean radiant temperature. These parameters can be quantified directly except mean radiant temperature (Tmrt). The most accurate method to quantify Tmrt is integral radiation measurements (3-D shortwave and long-wave) which require using expensive radiometer instruments. To overcome this limitation the well-known globe thermometer method was suggested to calculate Tmrt. The aim of this study was to assess the possibility of using indoor globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate. Globe thermometer method using small and large sizes of black-painted copper globes (50mm, 150mm) were used to estimate Tmrt and compare it with the reference Tmrt estimated by integral radiation method. The results revealed that the globe thermometer method considerably overestimated Tmrt during the middle of the day and slightly underestimated it in the morning and late evening. The difference between the two methods was obvious when the amount of incoming solar radiation was high. The results also showed that the effect of globe size on the estimated Tmrt is mostly small. Though, the estimated Tmrt by the small globe showed a relatively large amount of scattering caused by rapid changes in radiation and wind speed.

  15. Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters

    Science.gov (United States)

    Vlcek, Brian L.; Hendricks, Robert C.; Zaretsky, Erwin V.

    2013-01-01

    Leonard Johnson published a methodology for establishing the confidence that two populations of data are different. Johnson's methodology is dependent on limited combinations of test parameters (Weibull slope, mean life ratio, and degrees of freedom) and a set of complex mathematical equations. In this report, a simplified algebraic equation for confidence numbers is derived based on the original work of Johnson. The confidence numbers calculated with this equation are compared to those obtained graphically by Johnson. Using the ratios of mean life, the resultant values of confidence numbers at the 99 percent level deviate less than 1 percent from those of Johnson. At a 90 percent confidence level, the calculated values differ between +2 and 4 percent. The simplified equation is used to rank the experimental lives of three aluminum alloys (AL 2024, AL 6061, and AL 7075), each tested at three stress levels in rotating beam fatigue, analyzed using the Johnson- Weibull method, and compared to the ASTM Standard (E739 91) method of comparison. The ASTM Standard did not statistically distinguish between AL 6061 and AL 7075. However, it is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers using the Johnson- Weibull analysis. AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median, or L(sub 50), lives

  16. Tympanic ear thermometer assessment of body temperature among patients with cognitive disturbances. An acceptable and ethically desirable alternative?

    Science.gov (United States)

    Aadal, Lena; Fog, Lisbet; Pedersen, Asger Roer

    2016-12-01

    Investigation of a possible relation between body temperature measurements by the current generation of tympanic ear and rectal thermometers. In Denmark, a national guideline recommends the rectal measurement. Subsequently, the rectal thermometers and tympanic ear devices are the most frequently used and first choice in Danish hospital wards. Cognitive changes constitute challenges with cooperating in rectal temperature assessments. With regard to diagnosing, ethics, safety and the patients' dignity, the tympanic ear thermometer might comprise a desirable alternative to rectal noninvasive measurement of body temperature during in-hospital-based neurorehabilitation. A prospective, descriptive cohort study. Consecutive inclusion of 27 patients. Linear regression models were used to analyse 284 simultaneous temperature measurements. Ethical approval for this study was granted by the Danish Data Protection Agency, and the study was completed in accordance with the Helsinki Declaration 2008. About 284 simultaneous rectal and ear temperature measurements on 27 patients were analysed. The patient-wise variability of measured temperatures was significantly higher for the ear measurements. Patient-wise linear regressions for the 25 patients with at least three pairs of simultaneous ear and rectal temperature measurements showed large interpatient variability of the association. A linear relationship between the rectal body temperature assessment and the temperature assessment employing the tympanic thermometer is weak. Both measuring methods reflect variance in temperature, but ear measurements showed larger variation. © 2016 Nordic College of Caring Science.

  17. Co-amoxiclav-induced Stevens Johnson Syndrome in a child ...

    African Journals Online (AJOL)

    Stevens-Johnson Syndrome is an uncommon life threatening disease generally induced by drugs. Antibiotics, mainly sulphonamides, are the most involved drugs in Stevens-Johnson Syndrome in children. Co-amoxiclav is a well tolerated antibiotic. It has never been reported to cause, lonely this syndrome in children.

  18. Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.

    2017-09-01

    The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.

  19. Radiation stability of low-temperature resistance thermometers

    International Nuclear Information System (INIS)

    Neklyudov, I.M.; Petrusenko, Yu.T.; Sleptsov, A.N.; Logvinenko, S.P.; Mikhina, G.F.; Rossoshanskij, O.A.

    1989-01-01

    The effect of low temperature (∼ 5 and 11 K) irradiation with E=30 MeV electrons and the subsequent annealing at 180 and 300 K on gauge dependences R(T) of resistance thermometers (RT) on the basis of p-GaAs, Ni and In is investigated. For GaAs-RT the dependence of electroresistance R(4.2 K) on the irradiation fluence is shown to be non monotonic. The annealing at 180 and 300 K does not restore GaAs-RT thermometric characteristics but it leads to their further degradation. The annealing of Ni and In irradiated RT's at T>180 K leads to total restoring of their electrophysical properties. 16 refs.; 5 figs.; 1 tab

  20. Johnson-Wax Mijdrecht (Holanda

    Directory of Open Access Journals (Sweden)

    Maaskant van Dommelen Kroos, Arquitectos

    1972-09-01

    Full Text Available This Johnson factory, ideally located in the industrial zone of Mijdrecht, is an original building in both its design and its position on a lake which acts as a reflector. The set of offices is divided into three parts, taking into account that it has to function as a centre of international sales as well. Its special shape is perfectly suitable for future development, conditioned to the construction of a new adjacent road.Situada en la zona industrial de Mijdrecht, óptima por su emplazamiento, esta fábrica de la casa Johnson es un edificio original por su especial diseño y por su ubicación sobre un estanque, que actúa de elemento reflector. El conjunto de oficinas está dividido en tres partes, teniendo en cuenta que, además, ha de funcionar como centro de ventas internacional. Asimismo, su especial configuración está perfectamente adaptada a un futuro plan de ampliación de las instalaciones, condicionado a la construcción de una nueva carretera adyacente.

  1. 1/f noise: diffusive systems and music

    Energy Technology Data Exchange (ETDEWEB)

    Voss, R.F.

    1975-11-01

    Measurements of the 1/f voltage noise in continuous metal films are reported. At room temperature, samples of pure metals and bismuth (with a carrier density smaller by 10/sup 5/) of similar volume had comparable noise. The results suggest that the noise arises from equilibrium temperature fluctuations modulating the resistance. Spatial correlation of the noise implied that the fluctuations obey a diffusion equation. The empirical inclusion of an explicit 1/f region and appropriate normalization lead to excellent agreement with the measured noise. If the fluctuations are assumed to be spatially correlated, the diffusion equation can yield an extended 1/f region in the power spectrum. The temperature response of a sample to delta and step function power inputs is shown to have the same shape as the autocorrelation function for uncorrelated and correlated temperature fluctuations, respectively. The spectrum obtained from the cosine transform of the measured step function response is in excellent agreement with the measured 1/f voltage noise spectrum. Spatially correlated equilibrium temperature fluctuations are not the dominant source of 1/f noise in semiconductors and metal films. However, the agreement between the low-frequency spectrum of fluctuations in the mean-square Johnson noise voltage and the resistance fluctuation spectrum measured in the presence of a current demonstrates that in these systems the 1/f noise is also due to equilibrium resistance fluctuations. Loudness fluctuations in music and speech and pitch fluctuations in music also show the 1/f behavior. 1/f noise sources, consequently, are demonstrated to be the natural choice for stochastic composition. 26 figures, 1 table. (auth)

  2. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively

  3. Gamma thermometer allowing absolute and differential temperature measurements

    International Nuclear Information System (INIS)

    Bottin, P.; Schley, R.

    1985-01-01

    The gamma thermometer comprises an external envelope containing a cylindrical rod with a central bore and, thick and thin parts defining insulating chambers, at least one thermocouple set in the said central bore; the thermocouple has three junctions connected to one of their end parts by a junction at the level of a thin part, while one at least of the wires comprises two elements made of different materials connected by a junction at the level of a thick part. The present invention applies more particularly for detecting level of the coolant in a nuclear reactor [fr

  4. Application of the Johnson criteria to graphene transistors

    International Nuclear Information System (INIS)

    Kelly, M J

    2013-01-01

    For 60 years, the Johnson criteria have guided the development of materials and the materials choices for field-effect and bipolar transistor technology. Intrinsic graphene is a semi-metal, precluding transistor applications, but only under lateral bias is a gap opened and transistor action possible. This first application of the Johnson criteria to biased graphene suggests that this material will struggle to ever achieve competitive commercial applications. (fast track communication)

  5. TRACES OF JOHNSON IN THE LANGUAGE OF FANNY BURNEY

    Directory of Open Access Journals (Sweden)

    Randy Bax

    2005-06-01

    Full Text Available It has often been claimed that Frances Burney (1752-1840 was influenced linguistically by Samuel Johnson (1709-1784. Sorensen (1969: 390, and others with him, have even called her a "slavish imitator" of the language which Johnson used in his Rambler essays. Although far from simple guesswork, quantitative studies such as Sorensen's remain impressionistic, which makes it difficult to incorporate his (and similar observations in quantitative socio-histoncal linguistic studies of the English language. In the present study, the question whether Burney was indeed a serious imitator of Johnson's usage is answered by looking at the problem from a quantitative rather than qualitative perspective, and addressed within the framework of histoncai social network analysis.

  6. Thermometry in 3He

    International Nuclear Information System (INIS)

    Richardson, R.C.

    1977-01-01

    Some of the methods used in measuring the temperatures of the transitions in 3 He are reviewed. Although noise thermometers, γ-ray anisotropy thermometers and even Pt NMR thermometers are satisfactory for furnishing temperature standards, they are not satisfactory secondary thermometers. The susceptibility of CMN and various 3 He properties make more precise and quicker thermometric indications. (Auth.)

  7. JOHNSON-MATTHEY DIFFUSER CHARACTERIZATION TESTING

    International Nuclear Information System (INIS)

    Foster, P; James Klein, J; Henry Sessions, H; Gregg Morgan, G

    2007-01-01

    A diffuser/permeator commercially fabricated by Johnson-Matthey was purchased for characterization testing at the Savannah River National Laboratory (SRNL). A test system was fabricated to not only feed and bleed flows and pressures, but also permeate pressure for flows up to 20 SLPM

  8. Receive-Noise Analysis of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Bozkurt, Ayhan; Yaralioglu, G Goksenin

    2016-11-01

    This paper presents an analysis of thermal (Johnson) noise received from the radiation medium by otherwise noiseless capacitive micromachined ultrasonic transducer (CMUT) membranes operating in their fundamental resonance mode. Determination of thermal noise received by multiple numbers of transducers or a transducer array requires the assessment of cross-coupling through the radiation medium, as well as the self-radiation impedance of the individual transducer. We show that the total thermal noise received by the cells of a CMUT has insignificant correlation, and is independent of the radiation impedance, but is only determined by the mass of each membrane and the electromechanical transformer ratio. The proof is based on the analytical derivations for a simple transducer with two cells, and extended to transducers with numerous cells using circuit simulators. We used a first-order model, which incorporates the fundamental resonance of the CMUT. Noise power is calculated by integrating over the entire spectrum; hence, the presented figures are an upper bound for the noise. The presented analyses are valid for a transimpedance amplifier in the receive path. We use the analysis results to calculate the minimum detectable pressure of a CMUT. We also provide an analysis based on the experimental data to show that output noise power is limited by and comparable to the theoretical upper limit.

  9. Mycoplasma pneumoniae and atypical Stevens-Johnson syndrome: a case series.

    Science.gov (United States)

    Ravin, Karen A; Rappaport, Lara D; Zuckerbraun, Noel S; Wadowsky, Robert M; Wald, Ellen R; Michaels, Marian M

    2007-04-01

    Mycoplasma pneumoniae is a common cause of community-acquired respiratory illness in the adolescent population. Stevens-Johnson syndrome is an extrapulmonary manifestation that has been associated with M. pneumoniae infections. Three adolescent males presented within a 1-month period with M. pneumoniae respiratory illnesses and severe mucositis but without the classic rash typical of Stevens-Johnson. Diagnosis was facilitated by the use of a polymerase chain reaction-based assay. This case series highlights the potential for M. pneumoniae-associated Stevens-Johnson syndrome to occur without rash and supports the use of polymerase chain reaction for early diagnosis.

  10. Effect of colored noise on an overdamped Josephson junction

    Science.gov (United States)

    Genchev, Z. D.

    2001-03-01

    In this paper my attention is restricted to stochastic differential equation in phase function φ(t), describing an overdamped Josephson junction. I accept the RSJ (resistively shunted junction) modeling, when the contact characterized by resistance R and critical current I c is under the action of a given direct current I and stochastic current source Ĩ(t) (=0) : {ℏ}/{2 eR }{dφ }/{dt }+I csinφ=I+ Ĩ(t). In our case the thermal noise is a Gaussian process and obeys the Johnson-Nyquistr correlation law C(t)== {ℏ}/{2πR}∫ -∞∞dω ω coth{ℏω}/{2k BT }cosωt. The effective Fokker-Planck equation is derived and the current-voltage characteristics (CVCs) of the Josephson junction are calculated for weakly colored noise. In the limit limℏ→0C(t)= {2k BT }/{R}δ(t) the well-known results for white noise are recovered.

  11. 78 FR 16298 - Manufacturer of Controlled Substances, Notice of Registration; Johnson Matthey, Inc.

    Science.gov (United States)

    2013-03-14

    ... interest at this time. DEA has investigated Johnson Matthey, Inc., to ensure that the company's..., Notice of Registration; Johnson Matthey, Inc. By Notice dated November 5, 2012, and published in the Federal Register on November 13, 2012, 77 FR 67676, Johnson Matthey, Inc., Custom Pharmaceuticals...

  12. Analysis of noise in energy-dispersive spectrometers using time-domain methods

    CERN Document Server

    Goulding, F S

    2002-01-01

    This paper presents an integrated time domain approach to the optimization of the signal-to-noise ratio in all spectrometer systems that contain a detector that converts incoming quanta of radiation into electrical pulse signals that are amplified and shaped by an electronic pulse shaper. It allows analysis of normal passive pulse shapers as well as time-variant systems where switching of shaping elements occurs in synchronism with the signal. It also deals comfortably with microcalorimeters (sometimes referred to as bolometers), where noise-determining elements, such as the temperature-sensing element's resistance and temperature, change with time in the presence of a signal. As part of the purely time-domain approach, a new method of calculating the Johnson noise in resistors using only the statistics of electron motion is presented. The result is a time-domain analog of the Nyquist formula.

  13. 77 FR 16263 - Manufacturer of Controlled Substances, Notice of Registration; Johnson Matthey Inc.

    Science.gov (United States)

    2012-03-20

    ... the public interest at this time. DEA has investigated Johnson Matthey Inc. to ensure that the company..., Notice of Registration; Johnson Matthey Inc. By Notice dated November 18, 2011, and published in the Federal Register on November 28, 2011, 76 FR 72974, Johnson Matthey Inc., Custom Pharmaceuticals...

  14. 77 FR 24988 - Manufacturer of Controlled Substances; Notice of Registration; Johnson Matthey Inc.

    Science.gov (United States)

    2012-04-26

    .... DEA has investigated Johnson Matthey Inc. to ensure that the company's registration is consistent with...; Notice of Registration; Johnson Matthey Inc. By Notice dated November 21, 2011, and published in the Federal Register on November 29, 2011, 76 FR 73679, Johnson Matthey Inc., Pharmaceuticals Materials, 900...

  15. Correction of the dynamic response of the ''Gamma thermometers'' using a digital filter

    International Nuclear Information System (INIS)

    Jacquot, J.P.; Lobert, J.P.

    1985-01-01

    The ''gamma thermometer'' is a sensor used to measure on line the local power inside a PWR nuclear reactor. During transients, this sensor based on thermal exchanges, obes not give a fast response. This paper describes a microprocessor device that allows using a digital filtering technique, a correction of the dynamic response [fr

  16. Development of a superconducting transition edge thermometer for calorimetric detection of heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Meier, J; Boehmer, W; Egelhof, P; Henning, W; Kienlin, A v [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany) Mainz Univ. (Germany). Inst. fuer Physik; Shepard, K W [Argonne National Lab., IL (United States)

    1991-10-01

    A low temperature bolometer for the calorimetric detection of heavy ions was constructed and tested. An aluminium thin-film microstrip, patterned in a meander-line structure by photolithographic techniques, serves as superconducting transition edge thermometer on a sapphire absorber. A transition width {delta}T of the thermometer of the order of some mK, and a resistance of up to R{sub c} = 60 k{Omega} at the working point (T{sub c} {approx equal} 1.5 K) is achieved. In tests with {alpha}-particles signals of typically 1 V pulseheight after the preamplifier and decaytimes around hundred {mu}s were observed. For 5.5 MeV {alpha}-particles the measured energy resolution is {Delta}E = 50 keV, corresponding to a temperature resolution of about 1 {mu}K. First measurements were performed with {sup 20}Ne ions (E = 116 MeV). The dependence of the pulseheight and the FWHM on the working point were investigated and qualitatively explained. The best energy resolution was {Delta}E = 2.6 MeV; most probably the present limitations are determined by the temperature stabilization. (orig.).

  17. Dual-sensing porphyrin-containing copolymer nanosensor as full-spectrum colorimeter and ultra-sensitive thermometer.

    Science.gov (United States)

    Yan, Qiang; Yuan, Jinying; Kang, Yan; Cai, Zhinan; Zhou, Lilin; Yin, Yingwu

    2010-04-28

    A porphyrin-containing copolymer has dual-sensing in response to metal ions and temperature as a novel nanosensor. Triggered by ions, the sensor exhibits full-color tunable behavior as a cationic detector and colorimeter. Responding to temperature, the sensor displays an "isothermal" thermochromic point as an ultra-sensitive thermometer.

  18. 99mTc-HIDA cholescintigraphy in Dubin-Johnson and Rotor syndromes

    International Nuclear Information System (INIS)

    Bar-Meir, S.; Baron, J.; Seligson, U.; Gottesfeld, F.; Levy, R.; Gilat, T.

    1982-01-01

    99mTc-HIDA cholescintigraphy was performed in 6 patients with Dubin-Johnson syndrome and 1 patient with Rotor syndrome. In the patients with Dubin-Johnson syndrome, the cholescintigrams had a characteristic pattern of delayed visualization or nonvisualization of the gallbladder and bile ducts in the presence of intense, homogeneous, and prolonged visualization of the liver. In the patient with Rotor syndrome, the hepatobiliary system was not visualized at all. It is concluded that 99mTc-HIDA cholescintigraphy may be helpful in the diagnosis of Dubin-Johnson syndrome and Rotor syndrome and in the differential diagnosis between these two conditions

  19. Dissociation Pathways of Benzylpyridinium "Thermometer" Ions Depend on the Activation Regime: An IRMPD Spectroscopy Study

    NARCIS (Netherlands)

    Morsa, D.; Gabelica, V.; Rosu, F.; Oomens, J.; De Pauw, E.

    2014-01-01

    The dissociation of benzylpyridinium "thermometer" ions is widely used to calibrate the internal energy of ions produced in mass spectrometry. The fragmentation mechanism is usually believed to yield a benzylium cation, although recent studies suggest the possibility of a rearrangement leading to

  20. Aggressiveness of loose kernel smut isolate from Johnson grass on sorghum line BTx643

    Science.gov (United States)

    An isolate of loose kernel smut obtained from Johnson grass was inoculated unto six BTx643 sorghum plants in the greenhouse to determine its aggressiveness. All the BTx643 sorghum plants inoculated with the Johnson grass isolate were infected. Mean size of the teliospores from the Johnson grass, i...

  1. Severe jaundice due to coexistence of Dubin-Johnson syndrome and hereditary spherocytosis: a case report.

    Science.gov (United States)

    Korkmaz, Uğur; Duman, Ali Erkan; Oğütmen Koç, Deniz; Gürbüz, Yeşim; Dındar, Gökhan; Ensaroğlu, Fatih; Sener, Selçuk Yusuf; Sentürk, Omer; Hülagü, Sadettin

    2011-08-01

    Dubin-Johnson syndrome is a chronic, benign, intermittent jaundice, mostly of conjugated hyperbilirubinemia. The level of bilirubin is not expected to be more than 20 mg/dl in this syndrome. In this article, we report a patient who was evaluated for hyperbilirubinemia and liver function test abnormalities and diagnosed with Dubin-Johnson syndrome coexisting with hereditary spherocytosis. We suggest that other diseases should be investigated if patients with Dubin-Johnson syndrome present with severe hyperbilirubinemia. Dubin-Johnson syndrome accompanied by hemolytic diseases might also have high coproporphyrin levels (as in Rotor's syndrome) than expected in pure Dubin-Johnson syndrome.

  2. Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer.

    Science.gov (United States)

    Kreissl, Hannah; Neiger, Reto

    2015-01-01

    To assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). Prospective single center study. University teaching hospital. Three hundred dogs presented with low, normal, or high body temperatures. Three body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Median body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3°C (range 35.5°C-41.1°C; 95% CI: 38.2-38.4°C) and 37.7°C (35.9°C-40.1°C; 95% CI: 37.7°C-37.9°C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (rRDT = 0.94; rNCIT = 0.82; respectively, P temperature correlated poorly (r = 0.43; P temperature >39.0°C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time. © Veterinary Emergency and Critical Care Society 2015.

  3. Brood Year 2004: Johnson Creek Chinook Salmon Supplementation Report, June 2004 through March 2006.

    Energy Technology Data Exchange (ETDEWEB)

    Gebhards, John S.; Hill, Robert; Daniel, Mitch [Nez Perce Tribe

    2009-02-19

    The Nez Perce Tribe, through funding provided by the Bonneville Power Administration, has implemented a small scale chinook salmon supplementation program on Johnson Creek, a tributary in the South Fork of the Salmon River, Idaho. The Johnson Creek Artificial Propagation Enhancement project was established to enhance the number of threatened Snake River spring/summer chinook salmon (Oncorhynchus tshawytscha) returning to Johnson Creek to spawn through artificial propagation. This was the sixth season of adult chinook broodstock collection in Johnson Creek following collections in 1998, 2000, 2001, 2002, and 2003. Weir installation was completed on June 21, 2004 with the first chinook captured on June 22, 2004 and the last fish captured on September 6, 2004. The weir was removed on September 18, 2004. A total of 338 adult chinook, including jacks, were captured during the season. Of these, 211 were of natural origin, 111 were hatchery origin Johnson Creek supplementation fish, and 16 were adipose fin clipped fish from other hatchery operations and therefore strays into Johnson Creek. Over the course of the run, 57 natural origin Johnson Creek adult chinook were retained for broodstock, transported to the South Fork Salmon River adult holding and spawning facility and held until spawned. The remaining natural origin Johnson Creek fish along with all the Johnson Creek supplementation fish were released upstream of the weir to spawn naturally. Twenty-seven Johnson Creek females were artificially spawned with 25 Johnson Creek males. Four females were diagnosed with high bacterial kidney disease levels resulting in their eggs being culled. The 27 females produced 116,598 green eggs, 16,531 green eggs were culled, with an average eye-up rate of 90.6% resulting in 90,647 eyed eggs. Juvenile fish were reared indoors at the McCall Fish Hatchery until November 2005 and then transferred to the outdoor rearing facilities during the Visual Implant Elastomer tagging operation

  4. 77 FR 24988 - Manufacturer of Controlled Substances; Notice of Registration; Johnson Matthey Pharma Services

    Science.gov (United States)

    2012-04-26

    ...; Notice of Registration; Johnson Matthey Pharma Services By Notice dated December 5, 2011, and published in the Federal Register on December 12, 2011, 76 FR 77257, Johnson Matthey Pharma Services, 70... factors in 21 U.S.C. 823(a) and determined that the registration of Johnson Matthey Pharma Services to...

  5. Equilibrium and shot noise in mesoscopic systems

    Energy Technology Data Exchange (ETDEWEB)

    Martin, T.

    1994-10-01

    Within the last decade, there has been a resurgence of interest in the study of noise in Mesoscopic devices, both experimentally and theoretically. Noise in solid state devices can have different origins: there is 1/f noise, which is believed to arise from fluctuations in the resistance of the sample due to the motion of impurities. On top of this contribution is a frequency independent component associated with the stochastic nature of electron transport, which will be the focus of this paper. If the sample considered is small enough that dephasing and inelastic effects can be neglected, equilibrium (thermal) and excess noise can be completely described in terms of the elastic scattering properties of the sample. As mentioned above, noise arises as a consequence of random processes governing the transport of electrons. Here, there are two sources of randomness: first, electrons incident on the sample occupy a given energy state with a probability given by the Fermi-Dirac distribution function. Secondly, electrons can be transmitted across the sample or reflected in the same reservoir where they came from with a probability given by the quantum mechanical transmission/reflection coefficients. Equilibrium noise refers to the case where no bias voltage is applied between the leads connected to the sample, where thermal agitation alone allows the electrons close to the Fermi level to tunnel through the sample. In general, equilibrium noise is related to the conductance of the sample via the Johnson-Nyquist formula. In the presence of a bias, in the classical regime, one expects to recover the full shot noise < {Delta}{sup 2}I >= 2I{Delta}{mu} as was observed a long time ago in vacuum diodes. In the Mesoscopic regime, however, excess noise is reduced below the shot noise level. The author introduces a more intuitive picture, where the current passing through the device is a superposition of pulses, or electron wave packets, which can be transmitted or reflected.

  6. Time-Lapse and Slow-Motion Tracking of Temperature Changes: Response Time of a Thermometer

    Science.gov (United States)

    Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.

    2017-01-01

    We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure…

  7. HLA-B Sequencing in Patients with Stevens-Johnson Syndrome and Toxic Epidermal Necrolysis

    Science.gov (United States)

    2017-03-03

    Stevens -Johnson Syndrome and Toxic Epidermal Necrolysis Brittany L. Lenz, MD, Andrew T. Patterson, MD, Amanda J . Laska, MD, Patrick J . Brown, MD, and...59 MDW/SGVU SUBJECT: Professional Presentation Approval 8 DEC 2016 1. Your paper, entitled HLA-B Sequencing in Patients with Stevens -Johnson...PATIENTS WITH STEVENS -JOHNSON SYNDROME AND TOXIC EPIDERMAL NECROL YSIS 2. FUNDING RECEIVED FOR THIS STUDY? DYES rgj NO FUNDING SOURCE: I I 3. IS THIS

  8. Recovering Parameters of Johnson's SB Distribution

    Science.gov (United States)

    Bernard R. Parresol

    2003-01-01

    A new parameter recovery model for Johnson's SB distribution is developed. This latest alternative approach permits recovery of the range and both shape parameters. Previous models recovered only the two shape parameters. Also, a simple procedure for estimating the distribution minimum from sample values is presented. The new methodology...

  9. Networking at NASA. Johnson Space Center

    Science.gov (United States)

    Garman, John R.

    1991-01-01

    A series of viewgraphs on computer networks at the Johnson Space Center (JSC) are given. Topics covered include information resource management (IRM) at JSC, the IRM budget by NASA center, networks evolution, networking as a strategic tool, the Information Services Directorate charter, and SSC network requirements, challenges, and status.

  10. /sup 99m/Tc-HIDA cholescintigraphy in Dubin-Johnson and Rotor syndromes

    International Nuclear Information System (INIS)

    Bar-Meir; Baron, J.; Seligson, U.; Gottesfeld, F.; Levy, R.; Gilat, T.

    1982-01-01

    /sup 99m/Tc-HIDA cholescintigraphy was performed in 6 patients with Dubin-Johnson syndrome and 1 patient with Rotor syndrome. In the patients with Dubin-Johnson syndrome, the cholescintigrams had a characteristic pattern of delayed visualization or nonvisualization of the gallbladder and bile ducts in the presence of intense, homogeneous, and prolonged visualization of the liver. In the patient with Rotor syndrome, the hepatobiliary system was not visualized at all. It is concluded that /sup 99m/Tc-HIDA cholescintigraphy may be helpful in the diagnosis of Dubin-Johnson syndrome and Rotor syndrome and in the differential diagnosis between these two conditions

  11. The distress thermometer in survivors of gynaecological cancer

    DEFF Research Database (Denmark)

    Olesen, Mette L.; Hansen, Merete K.; Hansson, Helena

    2017-01-01

    Purpose: Unrecognised psychological distress among cancer survivors may be identified using short screening tools. We validated the accuracy of the distress thermometer (DT) to detect psychological distress on the Hospital Anxiety and Depression Scale (HADS) among early stage gynaecological cancer...... survivors and whether the women’s DT and HADS scores were associated with the need of an individualised supportive intervention. Methods: One hundred sixty-five gynaecological cancer survivors answered DT and HADS before randomisation in a trial testing a nurse-led, person-centred intervention using...... supportive conversations. The number of conversations was decided in the woman-nurse dyad based on the woman’s perceived need. Nurses were unaware of the women’s DT and HADS scores. We validated DT’s accuracy for screening using HADS as gold standard and receiver operating characteristic curves. Associations...

  12. Noise-based logic: Binary, multi-valued, or fuzzy, with optional superposition of logic states

    Energy Technology Data Exchange (ETDEWEB)

    Kish, Laszlo B. [Texas A and M University, Department of Electrical and Computer Engineering, College Station, TX 77843-3128 (United States)], E-mail: laszlo.kish@ece.tamu.edu

    2009-03-02

    A new type of deterministic (non-probabilistic) computer logic system inspired by the stochasticity of brain signals is shown. The distinct values are represented by independent stochastic processes: independent voltage (or current) noises. The orthogonality of these processes provides a natural way to construct binary or multi-valued logic circuitry with arbitrary number N of logic values by using analog circuitry. Moreover, the logic values on a single wire can be made a (weighted) superposition of the N distinct logic values. Fuzzy logic is also naturally represented by a two-component superposition within the binary case (N=2). Error propagation and accumulation are suppressed. Other relevant advantages are reduced energy dissipation and leakage current problems, and robustness against circuit noise and background noises such as 1/f, Johnson, shot and crosstalk noise. Variability problems are also non-existent because the logic value is an AC signal. A similar logic system can be built with orthogonal sinusoidal signals (different frequency or orthogonal phase) however that has an extra 1/N type slowdown compared to the noise-based logic system with increasing number of N furthermore it is less robust against time delay effects than the noise-based counterpart.

  13. Noise-based logic: Binary, multi-valued, or fuzzy, with optional superposition of logic states

    International Nuclear Information System (INIS)

    Kish, Laszlo B.

    2009-01-01

    A new type of deterministic (non-probabilistic) computer logic system inspired by the stochasticity of brain signals is shown. The distinct values are represented by independent stochastic processes: independent voltage (or current) noises. The orthogonality of these processes provides a natural way to construct binary or multi-valued logic circuitry with arbitrary number N of logic values by using analog circuitry. Moreover, the logic values on a single wire can be made a (weighted) superposition of the N distinct logic values. Fuzzy logic is also naturally represented by a two-component superposition within the binary case (N=2). Error propagation and accumulation are suppressed. Other relevant advantages are reduced energy dissipation and leakage current problems, and robustness against circuit noise and background noises such as 1/f, Johnson, shot and crosstalk noise. Variability problems are also non-existent because the logic value is an AC signal. A similar logic system can be built with orthogonal sinusoidal signals (different frequency or orthogonal phase) however that has an extra 1/N type slowdown compared to the noise-based logic system with increasing number of N furthermore it is less robust against time delay effects than the noise-based counterpart

  14. Noise-based logic: Binary, multi-valued, or fuzzy, with optional superposition of logic states

    Science.gov (United States)

    Kish, Laszlo B.

    2009-03-01

    A new type of deterministic (non-probabilistic) computer logic system inspired by the stochasticity of brain signals is shown. The distinct values are represented by independent stochastic processes: independent voltage (or current) noises. The orthogonality of these processes provides a natural way to construct binary or multi-valued logic circuitry with arbitrary number N of logic values by using analog circuitry. Moreover, the logic values on a single wire can be made a (weighted) superposition of the N distinct logic values. Fuzzy logic is also naturally represented by a two-component superposition within the binary case ( N=2). Error propagation and accumulation are suppressed. Other relevant advantages are reduced energy dissipation and leakage current problems, and robustness against circuit noise and background noises such as 1/f, Johnson, shot and crosstalk noise. Variability problems are also non-existent because the logic value is an AC signal. A similar logic system can be built with orthogonal sinusoidal signals (different frequency or orthogonal phase) however that has an extra 1/N type slowdown compared to the noise-based logic system with increasing number of N furthermore it is less robust against time delay effects than the noise-based counterpart.

  15. Determination of response time of resistance thermometers by in situ measurements

    International Nuclear Information System (INIS)

    Goncalves, I.M.P.; Soares, A.J.

    1986-01-01

    The loop-current-step-response test provides a mean for determining the time constant of resistance thermometers. The test consists in heating the sensor a few degrees above ambient temperature by causing a step perurbation in the electric current that flows through the sensor leads. The developed mathematical transformation permits to use data collected during the internal heating transient to predict the sensor response to perturbations in fluid temperature. Experimental data obtained show that time constant determined by this method is within 15 percent of the true value. (Author) [pt

  16. Johnson screen for cooling water intakes

    International Nuclear Information System (INIS)

    Cook, L.E.

    1978-01-01

    Johnson surface-water screens provide an alternative to vertical traveling screens for power plant cooling water intakes. In this paper, flow field modeling is discussed, and a series of case studies is presented. The hydraulic information obtained is discussed as it applies to the exclusion of biota and debris from cooling water intake systems

  17. XXI sajandi kontuurid / Paul Johnson ; refereerinud Mihkel Mutt

    Index Scriptorium Estoniae

    Johnson, Paul

    1997-01-01

    Washingtonis 14.-16. juunini peetud 'Lääne kirjanduse konverentsil' pidas põhiettekande ameerika ajaloolane ja publitsist Paul Johnson. Refereering tema 'XXI sajandi geopoliitiliste ja kultuuriliste väljavaadete' seisukohtadest

  18. Parcels and Land Ownership, Parcel boundaries for Johnson County Kansas based off of legal description. Used to show spatial reference to parcel boundaries of Johnson County Kansas., Published in 2007, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Parcels and Land Ownership dataset current as of 2007. Parcel boundaries for Johnson County Kansas based off of legal description. Used to show spatial reference to...

  19. Subharmonic frequency locking in the resistive Josephson thermometer

    International Nuclear Information System (INIS)

    van Veldhuizen, M.; Fowler, H.A.

    1985-01-01

    Phase-locked oscillatory solutions are examined as a basis for the dc impedance of the resistive superconducting quantum-interference device Josephson thermometer. The calculations are based on the resistively shunted junction model in the limit 2πL/sub s/I/sub c//Phi 0 > or =1, where L/sub s/ is the loop inductance and I/sub c/ is the junction critical current, and for a junction resistance large compared with the external shunt resistance. An algorithm for representing frequency entrainment in (kappa,ω) space (drive amplitude, frequency) leads to zones with rotation number p/q having the form of leaf-shaped regions joined and overlapping at their tips. High-resonance zones are very thin and locally similar. No chaotic behavior has been observed. The model can simulate the ''rising'' curves of dc impedance as a function of drive amplitude

  20. 77 FR 59986 - Johnson Controls Including Workers Whose Wages Were Reported Under IMECO LLC; North American...

    Science.gov (United States)

    2012-10-01

    ... applicable to workers and former workers of Johnson Controls, North American Refrigeration, Dixon, Illinois... to TA-W-71,663 is hereby issued as follows: All workers of Johnson Controls, including workers whose... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,663] Johnson Controls...

  1. Bilateral comparison for determining the dynamic characteristic values of contact thermometers in fluids

    Directory of Open Access Journals (Sweden)

    S. Augustin

    2018-05-01

    Full Text Available In applicable standards and sets of rules (VDI/VDE, 2014; DIN, 2010, 2017, recommendations are made concerning the types of experiments for determining the dynamic parameters in fluids (flowing water and flowing air under well-defined conditions. In the data sheets of the thermometer manufacturers, quite different specifications can be found, such as time percentage values or time constants. Only a few thermometer manufacturers specify the medium and flow conditions under which these parameters have been determined. Above all, it is not common practice to indicate a measurement uncertainty for the dynamic parameters found. In Augustin et al. (2017, a first model for the indication of the measurement uncertainty of dynamic parameters in flowing air was presented.The present paper describes the results of a bilateral comparison made for the first time for determining dynamic parameters in the laboratories of the JUMO GmbH & Co. KG Fulda company and at the Institute of Process Measurement and Sensor Technology of the TU Ilmenau. In doing so, two type-N thermocouples with different diameters were investigated in experimental facilities with flowing water and flowing air. Subsequently, the dynamic parameters found were compared with each other. The differences revealed mainly resulted from plant-specific parameters.

  2. 78 FR 46373 - Manufacturer of Controlled Substances; Notice of Registration; Johnson Matthey Pharmaceutical...

    Science.gov (United States)

    2013-07-31

    ...; Notice of Registration; Johnson Matthey Pharmaceutical Materials, Inc. By Notice dated March 20, 2013, and published in the Federal Register on March 28, 2013, 78 FR 19017, Johnson Matthey Pharmaceutical Materials, Inc., Pharmaceutical Services, 25 Patton Road, Devens, Massachusetts 01434, made application by...

  3. Stevens-Johnson Syndrome (SJS) and Toxic Epidermal Necrolysis ...

    African Journals Online (AJOL)

    REVIEW. Introduction. Stevens-Johnson syndrome (SJS) and toxic epidermal ... that affect the skin and mucous membranes. ... Open Access article distributed under the terms of the .... pathogenic components are removed from plasma. The.

  4. Stevens Johnsons syndrom og toksisk epidermal nekrolyse

    DEFF Research Database (Denmark)

    Kaur-Knudsen, Diljit; Zachariae, Claus; Thomsen, Simon Francis

    2013-01-01

    Stevens-Johnson syndrome and toxic epidermal necrolysis are acute mucocutaneous diseases primarily due to drug intake. The diseases are characterised by the separation of epidermis from dermis which can be life-threatening. Mortality is often caused by sepsis and multiple organ failure. The most...

  5. [Fatal toxic respiratory epitheliolysis. Subacute tracheo-bronchial desquamation in Stevens-Johnson syndrome].

    Science.gov (United States)

    Martin, L; Hazouard, E; Michalak-Provost, S; Maurage, C; Machet, L

    2001-09-01

    Acute bronchial mucosal sloughing related to Toxic Epidermal Necrolysis (Lyell syndrome) is widely reported in literature. On the contrary severe respiratory involvement is rare in post-infectious or toxic Epitheliolysis (Stevens-Johnson syndrome). There is no well-known predictive sign of bronchial epithelium involvement. An 18-year-old patient was admitted for Stevens-Johnson syndrome related to sulfasalazine (salazosulfapyridine). There were no respiratory signs. An acute respiratory failure occurred 36 hours after from admission due to an obstructive and desquamative necrosis of the tracheobronchial epithelium. We purpose that a fiberoptic laryngoscopy should be performed even in non-dyspneic patients suffering from Stevens-Johnson syndrome if hypersecretion is present. Fiberoptic bronchoscopy can be helpful in these cases.

  6. 78 FR 15975 - Manufacturer of Controlled Substances, Notice of Registration; Johnson Matthey, Inc...

    Science.gov (United States)

    2013-03-13

    ..., Notice of Registration; Johnson Matthey, Inc., Pharmaceuticals Materials By Notice dated November 1, 2012, and published in the Federal Register on November 9, 2012, 77 FR 67397, Johnson Matthey, Inc...) II The company plans to manufacture the listed controlled substances in bulk for distribution and...

  7. Canonical extensions of the Johnson homomorphisms to the Torelli groupoid

    DEFF Research Database (Denmark)

    Bene, Alex; Kawazumi, Nariya; Penner, Robert

    2009-01-01

    We prove that every trivalent marked bordered fatgraph comes equipped with a canonical generalized Magnus expansion in the sense of Kawazumi. This Magnus expansion is used to give canonical extensions of the higher Johnson homomorphisms τm , for m 1 , to the Torelli groupoid, and we provide...... a recursive combinatorial formula for tensor representatives of these extensions. In particular, we give an explicit 1-cocycle in the dual fatgraph complex which extends τ2 and thus answer affirmatively a question of Morita and Penner. To illustrate our techniques for calculating higher Johnson homomorphisms...

  8. 77 FR 30028 - Manufacturer of Controlled Substances; Notice of Registration; Johnson Matthey, Inc...

    Science.gov (United States)

    2012-05-21

    ...; Notice of Registration; Johnson Matthey, Inc., Pharmaceuticals Materials By Notice dated January 6, 2012, and published in the Federal Register on January 17, 2012, 77 FR 2324, Johnson Matthey, Inc... (9333) II The company plans to manufacture the listed controlled substances in bulk for sale to its...

  9. Parent-Child Agreement Using the Spence Children's Anxiety Scale and a Thermometer in Children with Autism Spectrum Disorder

    Science.gov (United States)

    May, T.; Cornish, K.; Rinehart, N. J.

    2015-01-01

    Children with Autism Spectrum Disorder (ASD) experience high anxiety which often prompts clinical referral and requires intervention. This study aimed to compare parent and child reports on the Spence Children's Anxiety Scale (SCAS) and a child-reported “worry thermometer” in 88 children aged 8–13 years, 44 with ASD and 44 age, gender, and perceptual IQ matched typically developing children. There were no gender differences in child report on the SCAS and worry thermometers. Results indicated generally good correlations between parent and child self-reported SCAS symptoms for typically developing children but poor agreement in parent-child ASD dyads. The worry thermometer child-report did not reflect child or parent reports on the SCAS. Findings suggest 8–13-year-old children with ASD may have difficulties accurately reporting their anxiety levels. The clinical implications were discussed. PMID:25922765

  10. 77 FR 67397 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey, Inc.

    Science.gov (United States)

    2012-11-09

    ...; Notice of Application; Johnson Matthey, Inc. Pursuant to Sec. 1301.33(a), Title 21 of the Code of Federal Regulations (CFR), this is notice that on September 10, 2012, Johnson Matthey, Inc., Pharmaceuticals Materials... Thebaine (9333) II The company plans to manufacture the listed controlled substances in bulk for...

  11. 78 FR 5499 - Manufacturer of Controlled Substances; Notice of Registration; Johnson Matthey, Inc.

    Science.gov (United States)

    2013-01-25

    ...; Notice of Registration; Johnson Matthey, Inc. By Notice dated May 9, 2012, and published in the Federal Register on May 21, 2012, 77 FR 30026, Johnson Matthey, Inc., Custom Pharmaceuticals Department, 2003 Nolte... substance listed in schedule II. The company plans to manufacture the listed controlled substance for sale...

  12. 78 FR 19016 - Importer of Controlled Substances; Notice of Registration; Johnson Matthey, Inc.

    Science.gov (United States)

    2013-03-28

    ... Registration; Johnson Matthey, Inc. By Notice dated November 19, 2012, and published in the Federal Register on November 27, 2012, 77 FR 70824, Johnson Matthey, Inc., Pharmaceutical Materials, 2003 Nolte Drive, West... Concentrate (9670) II The company plans to import the listed controlled substances as raw materials, to be...

  13. Johnson-Matthey diffuser characterization testing

    International Nuclear Information System (INIS)

    Foster, P. J.; Klein, J. E.; Sessions, H. T.; Morgan, G. A.

    2008-01-01

    A diffuser/permeator commercially fabricated by Johnson-Matthey was purchased for characterization testing at the Savannah River National Laboratory (SRNL). A test system was fabricated to test not only feed and bleed flows and pressures, but also permeate pressure for flows up to 20 sLPM. The tests described in this paper consider the effect of various inert gas types, feed gas compositions, methods for temperature control, and varying tube pressure on permeation of H 2 through the Pd/Ag tubes. (authors)

  14. Semi-transparent gold film as simultaneous surface heater and resistance thermometer for nucleate boiling studies

    International Nuclear Information System (INIS)

    Oker, E.; Merte, H. Jr.

    1981-01-01

    A large (22 x 25 mm) semi-transparent thin film of gold, approximately 400 A in thickness, is deposited on a glass substrate for simultaneous use as a heat source and resistance thermometer. Construction techniques and calibration procedures are described, and a sample application to a transient boiling process is included with simultaneous high speed photographs taken through the thin film from beneath

  15. 78 FR 69132 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey, Inc.

    Science.gov (United States)

    2013-11-18

    ...; Notice of Application; Johnson Matthey, Inc. Pursuant to Sec. 1301.33(a), Title 21 of the Code of Federal Regulations (CFR), this is notice that on September 5, 2013, Johnson Matthey Inc., Custom Pharmaceuticals... Remifentanil (9739) II Sufentanil (9740) II Tapentadol (9780) II Fentanyl (9801) II The company plans to...

  16. 78 FR 69133 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey, Inc.

    Science.gov (United States)

    2013-11-18

    ...; Notice of Application; Johnson Matthey, Inc. Pursuant to Sec. 1301.33(a), Title 21 of the Code of Federal Regulations (CFR), this is notice that on September 5, 2013, Johnson Matthey, Inc., Pharmaceuticals Materials... Methadone (9250) II Methadone intermediate (9254) II Morphine (9300) II Thebaine (9333) II The company plans...

  17. 77 FR 30026 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey, Inc.

    Science.gov (United States)

    2012-05-21

    ...; Notice of Application; Johnson Matthey, Inc. Pursuant to Sec. 1301.33(a), Title 21 of the Code of Federal Regulations (CFR), this is notice that on March 26, 2012, Johnson Matthey, Inc., Custom Pharmaceuticals...), a basic class of controlled substance listed in schedule II. The company plans to manufacture the...

  18. 77 FR 67676 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey Inc.

    Science.gov (United States)

    2012-11-13

    ...; Notice of Application; Johnson Matthey Inc. Pursuant to Sec. 1301.33(a), Title 21 of the Code of Federal Regulations (CFR), this is notice that on September 10, 2012, Johnson Matthey Inc., Custom Pharmaceuticals... Remifentanil (9739) II Sufentanil (9740) II Fentanyl (9801) II The company plans to manufacture the listed...

  19. 123 Holy Johnson's Patriotism: an Ethical Challenge to

    African Journals Online (AJOL)

    User

    2010-10-17

    Oct 17, 2010 ... that James Johnson had been living several years before 1840, the date ascribed .... Hitherto assume it has been the fashion among scholars to that .... third millennium and fifty years after political independence, Nigeria as a.

  20. A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

    Science.gov (United States)

    Kahle, Duncan; Aslam, Shahid; Herrero, Frederico A.; Waczynski, Augustyn

    2016-01-01

    A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

  1. A discrete component low-noise preamplifier readout for a linear (1×16) SiC photodiode array

    Energy Technology Data Exchange (ETDEWEB)

    Kahle, Duncan [NASA, Goddard Space Flight Center, Detector Systems Branch, Greenbelt, MD 20771 (United States); Aslam, Shahid, E-mail: shahid.aslam-1@nasa.gov [NASA, Goddard Space Flight Center, Planetary Systems Laboratory, Greenbelt, MD 20771 (United States); Herrero, Federico A.; Waczynski, Augustyn [NASA, Goddard Space Flight Center, Detector Systems Branch, Greenbelt, MD 20771 (United States)

    2016-09-11

    A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1×16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analog signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

  2. 77 FR 16262 - Importer of Controlled Substances, Notice of Registration; Johnson Matthey, Inc., Pharmaceutical...

    Science.gov (United States)

    2012-03-20

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Importer of Controlled Substances, Notice of Registration; Johnson Matthey, Inc., Pharmaceutical Materials By Notice dated December 2, 2011, and published in the Federal Register on December 12, 2011, 76 FR 77253, Johnson Matthey, Inc., Pharmaceutical...

  3. Method for determining the outlet temperature of fuel assemblies unsupplied with thermometer in WWER-440 reactors

    International Nuclear Information System (INIS)

    Miko, S.; Kalya, Z.; Hamvas, I.

    1987-09-01

    The paper outlines a method for the evaluation of the outlet temperatures of fuel assemblies unsupplied with thermometer in WWER-440 reactors. The process is based on interpolation of directly measured assembly temperatures. A quantitative comparison of the errors of described algorithm to those of standard plant-computer interpolation rutine is also presented. (author)

  4. Use of infrared thermometer technique in irrigation scheduling of pomegranate (Punica granatum L. plant

    Directory of Open Access Journals (Sweden)

    Begüm TEKELİOĞLU

    2017-06-01

    Full Text Available The main objectives of this study are to assess crop water stress index (CWSI and to determine irrigation schedule of pomegranate using infrared thermometer technique. Treatments with three replications were irrigated every three and six days intervals, as much as 0.50 (S1, 0.75 (S2, 1.00 (S3, and 1.25 (S4 of Class A pan evaporation. Additionally, an unirrigated plot was also formed. The equations obtained for non-water stress baseline is Tc-Ta=0.645VPD-4.338. The equation of full water stressed upper baseline obtained from data taken from branches of pomegranate plant cut in different days is given by Tc-Ta= 0.0489VPD+2.8734. According to the results obtained, it is concluded that infrared thermometer can be used for irrigation scheduling of the pomegranate plants in Antalya conditions. When using this technique in Antalya conditions, it is suggested to keep the seasonal mean CWSI value approximately 0.12 and the index value of 0.40 can be used to start the irrigation. Additionally, it is suggested that the amount of irrigation can be determined as much as the amount of evaporation measured until the index value reaches 0.40.

  5. Thermometer by optical fiber for ampacity studies in overhead transmission lines; Termometro a fibra optica para estudo da ampacidade em linhas de transmissao aereas

    Energy Technology Data Exchange (ETDEWEB)

    Valente, L.C.G.; Kawase, L.R.; Silva Filho, J.I. da; Silva, J.M.M. da [Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, RJ (Brazil); Igarashi, A.Y. [Universidade Federal, Rio de Janeiro, RJ (Brazil)

    1995-12-31

    This article suggests the utilization of thermometers constructed from optical fibers technology in overhead power transmission lines. This will help the studies in progress about the electric power systems ampacity. It also presents the advantages of using optical fibers instead of conventional thermometers. As an example, the fact that the optical fibers are dielectric and make possible the remote monitoring. It is also shown a possibility of introducing such measuring system in electric junctions where OPGW cables are used 4 refs., 4 figs.; e-mail: liliana at fis.puc-rio.br

  6. Parent-Child Agreement Using the Spence Children’s Anxiety Scale and a Thermometer in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    T. May

    2015-01-01

    Full Text Available Children with Autism Spectrum Disorder (ASD experience high anxiety which often prompts clinical referral and requires intervention. This study aimed to compare parent and child reports on the Spence Children’s Anxiety Scale (SCAS and a child-reported “worry thermometer” in 88 children aged 8–13 years, 44 with ASD and 44 age, gender, and perceptual IQ matched typically developing children. There were no gender differences in child report on the SCAS and worry thermometers. Results indicated generally good correlations between parent and child self-reported SCAS symptoms for typically developing children but poor agreement in parent-child ASD dyads. The worry thermometer child-report did not reflect child or parent reports on the SCAS. Findings suggest 8–13-year-old children with ASD may have difficulties accurately reporting their anxiety levels. The clinical implications were discussed.

  7. Performance of Magnetic Penetration Thermometers for X-Ray Astronomy

    Science.gov (United States)

    Nagler, P. C.; Adams, J. S.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Hsieh, W. T.; Kelly, D. P.; Porst, J. P.; Sadleir, J. E.; Seidel, G. M.; hide

    2012-01-01

    The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than leV FWHM for energies up to 10 keY. We have microfabricated and characterized thin-film magnetic penetration thermometers (MPTs) that show great promise towards meeting these capabilities. MPTs operate in similar fashion to metallic magnetic calorimeters (MMCs), except that a superconducting sensor takes the place of a paramagnetic sensor and it is the temperature dependence of the superconductor's diamagnetic response that provides the temperature sensitivity. We present a description of the design and performance of our prototype thin-film MPTs with MoAu bilayer sensors, which have demonstrated an energy resolution of approx 2 eV FWHM at 1.5 keY and 4.3 eV FWHM at 5.9 keY.

  8. Stevens-Johnson syndrome in a patient with rheumatoid arthritis during long-term etanercept therapy.

    Science.gov (United States)

    Owczarczyk-Saczonek, Agnieszka; Zdanowska, Natalia; Znajewska-Pander, Aleksandra; Placek, Waldemar

    2016-03-31

    Etanercept and other anti-TNF-alpha agents have been indicated as a therapeutic option in severe drug reactions, including Stevens-Johnson syndrome and toxic epidermal necrolysis. Etanercept has been shown to quickly reduce the detachment of the epidermis and shorten healing time. Cases of etanercept-induced severe adverse drug reactions were also described. A 27-year-old woman with a 4-year history of etanercept and sulfasalazine treatment for rheumatoid arthritis was admitted with Stevens-Johnson syndrome. The patient received one dose of an OTC drug containing acetaminophen, phenylephrine and pheniramine two days prior to developing fist mucocutaneous symptoms. The most probable causative agent was paracetamol. Throughout the successful routine therapy of Stevens-Johnson syndrome etanercept therapy was continued. Sulfosalazin administration was stopped and administered again after recovery with no recurrence of the skin and mucosal symptoms. This case indicates that there is no justification for discontinuation of long-term anti-TNF-alpha treatment in patients who develop Stevens- Johnson syndrome / toxic epidermal necrolysis.

  9. Linking Gateway Technical College with Workforce Development: The SC Johnson-A Family Company Story.

    Science.gov (United States)

    Knudson, Edward

    2004-01-01

    Seven years ago, SC Johnson--A Family Company approached Gateway Technical College with a need to further strengthen their incumbent workforce's technical training and education. Retirements, brain drain, and competition for technical expertise were the forces driving SC Johnson to develop a comprehensive, flexible, and timely workplace education…

  10. Fatal nevirapine-induced Stevens- Johnson syndrome with HIV ...

    African Journals Online (AJOL)

    2014-06-01

    Jun 1, 2014 ... of Stevens-Johnson syndrome highlights the dilemmas and complications that may arise when prescribing multiple medications in HIV-associated ... HIV enters the central nervous system early in the course of HIV ... Affected individuals with SJS/TEN are genetically predisposed to developing severe ...

  11. Application of Monte Carlo Method for Evaluation of Uncertainties of ITS-90 by Standard Platinum Resistance Thermometer

    Science.gov (United States)

    Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin

    2017-06-01

    Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.

  12. Genetics Home Reference: Stevens-Johnson syndrome/toxic epidermal necrolysis

    Science.gov (United States)

    ... Hung SI. Recent advances in the genetics and immunology of Stevens-Johnson syndrome and toxic epidermal necrosis. ... 2012 May 29. Citation on PubMed or Free article on PubMed Central More from Genetics Home Reference ...

  13. Síndrome de Stevens-Johnson: Presentación de 1 caso

    Directory of Open Access Journals (Sweden)

    Luisa María Pacheco Álvarez

    2001-12-01

    Full Text Available El síndrome de Stevens-Johnson, es una enfermedad inflamatoria aguda, originada por una hipersensibilidad, que incluye la piel y las membranas mucosas; en una forma mayor pone en peligro la vida del paciente. Puede ser inducida por muchos factores precipitantes, desde los medicamentos hasta una infección. La afección se caracteriza por una súbita erupción morfológicamente variable, acompañada de estomatitis y oftalmia. En este trabajo se presenta un niño de 8 años de edad, con la entidad clínica en forma muy severa, el síndrome de Stevens-Johnson, que involucra manifestaciones cutáneas, oculares y de la mucosa oral, acompañada de otras complicaciones graves, por lo que requirió terapéutica en cuidados intensivos, y se logró una evolución satisfactoria del paciente.Stevens-Johnson syndrome is an acute inflammatory disease caused by a hypersensibility that includes the skin and the mucous membranes and that in a severe form endangers the patient’s life. It may be induced by many precipitating factors, from drugs to infection. The affection is characterized by a sudden morphologically variable rash, accompanied with stomatitis and ophthalmia. An 8-year-old boy suffering from this clinical entity in a very severe form, Stevens-Johnson syndrome, with skin , ocular and oral mucosa manifestations and with other serious complications, is presented in this paper. He had to be treated at the ICU and a satisfactory evolution was attained.

  14. Risk of nevirapine-associated Stevens-Johnson syndrome among ...

    African Journals Online (AJOL)

    Background. Stevens-Johnson syndrome (SJS) is an acute life-threatening condition often elicited by drugs. The government's indecisiveness in deciding to stop the use of nevirapine (NVP) in HIV-infected pregnant women owing to the increase of SJS among this population group in South Africa prompted this investigation ...

  15. Digital bedrock geologic map of the Johnson quadrangle, Vermont

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital Data from VG98-2 Thompson, PJ�and Thompson, TB, 1998,�Digital bedrock geologic map of the Johnson quadrangle, Vermont: VGS Open-File Report VG98-2, 2 plates,...

  16. 78 FR 34428 - Missouri Central Railroad Company-Abandonment Exemption-in Cass, Henry, Johnson, and Pettis...

    Science.gov (United States)

    2013-06-07

    ... No. AB 1070; (Sub-No. 1X)] Missouri Central Railroad Company--Abandonment Exemption--in Cass, Henry, Johnson, and Pettis Counties, MO; Central Midland Railway Company--Discontinuance of Service Exemption--in Cass, Henry, Johnson, and Pettis Counties, MO Missouri Central Railroad Company (MCRR) and Central...

  17. The Finite Strain Johnson Cook Plasticity and Damage Constitutive Model in ALEGRA.

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Jason James [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    A finite strain formulation of the Johnson Cook plasticity and damage model and it's numerical implementation into the ALEGRA code is presented. The goal of this work is to improve the predictive material failure capability of the Johnson Cook model. The new implementation consists of a coupling of damage and the stored elastic energy as well as the minimum failure strain criteria for spall included in the original model development. This effort establishes the necessary foundation for a thermodynamically consistent and complete continuum solid material model, for which all intensive properties derive from a common energy. The motivation for developing such a model is to improve upon ALEGRA's present combined model framework. Several applications of the new Johnson Cook implementation are presented. Deformation driven loading paths demonstrate the basic features of the new model formulation. Use of the model produces good comparisons with experimental Taylor impact data. Localized deformation leading to fragmentation is produced for expanding ring and exploding cylinder applications.

  18. Torelli groups, extended Johnson homomorphisms, and new cycles on the moduli space of curves

    DEFF Research Database (Denmark)

    Morita, Shigeyuki; Penner, Robert

    modulo N are derived for all N. Furthermore, the first Johnson homomorphism, which is defined from the classical Torelli group to the third exterior power of the homology of the surface, is shown to lift to an explicit canonical 1-cocycle of the Teichmueller space. The main tool for these results...... cocycle lifts of the higher Johnson homomorphisms....

  19. Proposed Use of Zero Bias Diode Arrays as Thermal Electric Noise Rectifiers and Non-Thermal Energy Harvesters

    Science.gov (United States)

    Valone, Thomas F.

    2009-03-01

    The well known built-in voltage potential for some select semiconductor p-n junctions and various rectifying devices is proposed to be favorable for generating DC electricity at "zero bias" (with no DC bias voltage applied) in the presence of Johnson noise or 1/f noise which originates from the quantum vacuum (Koch et al., 1982). The 1982 Koch discovery that certain solid state devices exhibit measurable quantum noise has also recently been labeled a finding of dark energy in the lab (Beck and Mackey, 2004). Tunnel diodes are a class of rectifiers that are qualified and some have been credited with conducting only because of quantum fluctuations. Microwave diodes are also good choices since many are designed for zero bias operation. A completely passive, unamplified zero bias diode converter/detector for millimeter (GHz) waves was developed by HRL Labs in 2006 under a DARPA contract, utilizing a Sb-based "backward tunnel diode" (BTD). It is reported to be a "true zero-bias diode." It was developed for a "field radiometer" to "collect thermally radiated power" (in other words, 'night vision'). The diode array mounting allows a feed from horn antenna, which functions as a passive concentrating amplifier. An important clue is the "noise equivalent power" of 1.1 pW per root hertz and the "noise equivalent temperature difference" of 10° K, which indicate sensitivity to Johnson noise (Lynch, et al., 2006). There also have been other inventions such as "single electron transistors" that also have "the highest signal to noise ratio" near zero bias. Furthermore, "ultrasensitive" devices that convert radio frequencies have been invented that operate at outer space temperatures (3 degrees above zero point: 3° K). These devices are tiny nanotech devices which are suitable for assembly in parallel circuits (such as a 2-D array) to possibly produce zero point energy direct current electricity with significant power density (Brenning et al., 2006). Photovoltaic p-n junction

  20. Lyndon Baines Johnson signs the Wilderness Act into law

    Science.gov (United States)

    Susan A. Fox

    2016-01-01

    President Lyndon Baines Johnson signed the Wilderness Act into law on Sept. 3, 1964. In this photo, LBJ hands the pen he used to Alice Zahniser while naturalist, author, adventurer, and conservationist Mardy Murie (standing behind her) looks on.

  1. Germanium thermometers in the temperature range .1000K to 4.20K

    International Nuclear Information System (INIS)

    Hsieh, S.Y.; Sanchez, D.H.

    1974-01-01

    The sensitivity characteristics of two germanium thermometers that proved to be convenient sensors in the temperature range from .100 0 K to 4.2 0 K, are described. Their resistances change from about 8 x 10 5 ohms at .100 0 K to about 100 ohms at 4.2 0 K. The calibration curves were fitted to natural spline functions of order 3 in the whole range of temperatures. These functions give less than half millidegree standard dispersion against 15 millidegree standard dispersion when usual polynomial interpolations are used. It is discussed what spline functions are, and compare the goodness of spline interpolation with polynomial methods [pt

  2. Evaluation of conjunctival bacterial flora in patients with Stevens-Johnson Syndrome

    Directory of Open Access Journals (Sweden)

    Luciana Frizon

    2014-03-01

    Full Text Available OBJECTIVE: To determine the conjunctival bacterial flora present in patients with Stevens-Johnson syndrome. METHODS: A prospective study of the conjunctival bacterial flora was performed in 41 eyes of 22 patients with Stevens-Johnson syndrome. The information gathered included the patient's sex and age, the duration of disease, the cause of Stevens-Johnson syndrome, and treatments. Scrapings of the inferior conjunctival fornix were performed in both eyes. Fourteen days before scraping, the patients were asked to interrupt all topical medication and start using 0.5% nonpreserved methylcellulose. The microbiological evaluation included microorganism identification and determination of antibiotic sensitivity. RESULTS: Of 22 patients (41 eyes, 14 (64% were females, and eight (36% were males. The mean age was 33.2 years, and the mean duration of disease was 15.6 years. Visual acuity ranged from light perception to 20/25 (1.57 logMar. The treatment received by most patients consisted of tear substitutes, topical antibiotics, and contact lenses. Bacterial identification was positive in 39 eyes (95% and negative in two eyes (5%. Gram-positive cocci accounted for 55.5% of the microorganisms, whereas gram-positive bacilli and gram-negative bacilli accounted for 19% and 25.5%, respectively. Half of the patients (54% had multiple bacterial species in their flora, and only one bacterial species was identified in the other half. Resistant bacteria were isolated from four eyes. The antibiotic sensitivity results for the Streptococcus group showed the lowest sensitivity and the highest microbial resistance identified. CONCLUSION: Patients with Stevens-Johnson syndrome have a diverse conjunctival flora that includes many pathogenic species.

  3. Designing a TAC thermometer from a VHTR graphite structure

    Energy Technology Data Exchange (ETDEWEB)

    Smith, James A., E-mail: James.Smith@INL.gov; Kotter, Dale, E-mail: James.Smith@INL.gov [Fuel Performance and Design, Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Garrett, Steven L.; Ali, Randall A. [Graduate Program in Acoustics, Penn State University, State College, PA (United States)

    2015-03-31

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. Very High Temperature Reactors are pushing the in core temperatures even higher. A unique sensing approach will be discussed to address the necessary high temperature measurements. Thermoacoustic thermometry exploits high temperatures and uses materials that are immune to the effects of ionizing radiation to create a temperature sensor that is self-powered and wireless. In addition, the form-factor for the Thermoacoustic Thermometer (TACT) can be designed to be integrated within common in-pile structures. There are no physical moving parts required for TACT and the sensor is self-powered, as it uses the nuclear fuel for its heat source. TACT data will be presented from a laboratory prototype mimicking the design necessary for a VHTR graphite structure.

  4. MHD peristaltic motion of Johnson-Segalman fluid in a channel with compliant walls

    International Nuclear Information System (INIS)

    Hayat, T.; Javed, Maryiam; Asghar, S.

    2008-01-01

    A mathematical model for magnetohydrodynamic (MHD) flow of a Johnson-Segalman fluid in a channel with compliant walls is analyzed. The flow is engendered due to sinusoidal waves on the channel walls. A series solution is developed for the case in which the amplitude ratio is small. Our computations show that the mean axial velocity of a Johnson-Segalman fluid is smaller than that of a viscous fluid. The variations of various interesting dimensionless parameters are graphed and discussed

  5. Bronchiolitis obliterans in children with Stevens-Johnson syndrome: follow-up with high resolution CT

    International Nuclear Information System (INIS)

    Kim, M.J.; Lee, K.Y.

    1996-01-01

    About one third of children with Stevens-Johnson syndrome have pulmonary involvement. As a consequence of airway epithelial injury, bronchiolitis obliterans can occur in these patients. Two cases of Stevens-Johnson syndrome-associated bronchiolitis obliterans in children were diagnosed and followed by high resolution CT without open lung biopsy. Serial changes of high resolution CT features of bronchiolitis obliterans are discussed and the literature is reviewed. (orig.)

  6. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    Energy Technology Data Exchange (ETDEWEB)

    Keawprasert, T. [National Institute of Metrology Thailand, Pathum thani (Thailand); Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S. [Physikalisch Technische Bundesanstalt, Braunschweig and Berlin (Germany)

    2013-09-11

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

  7. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    International Nuclear Information System (INIS)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S.

    2013-01-01

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody

  8. Concurrence of Stevens-Johnson Syndrome and Bilateral Parotitis after Minocycline Therapy

    Directory of Open Access Journals (Sweden)

    Jimi Yoon

    2010-06-01

    Full Text Available Minocycline is an antibiotic of tetracycline derivatives that is commonly used in the treatment of moderate to severe acne vulgaris. It has been reported to cause rare adverse events from mild cutaneous eruption to severe forms including drug-induced lupus, serum sickness-like reaction, and hypersensitivity reactions, etc. The risks of adverse events attributed to minocycline have not been ascertained reliably and there are concerns about the safety of minocycline which could possibly result in life-threatening events such as the Stevens-Johnson syndrome. Here we demonstrate an unusual case of Stevens-Johnson syndrome in conjunction with bilateral parotitis after the intake of minocycline in a Korean boy suggesting discreet use of the drug.

  9. Road Bridges and Culverts, Bridge dataset only includes bridges maintained by Johnson County Public Works in the unincorporated areas, Published in Not Provided, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Road Bridges and Culverts dataset current as of unknown. Bridge dataset only includes bridges maintained by Johnson County Public Works in the unincorporated areas.

  10. Phenobarbital induced Stevens–Johnson syndrome in a child

    OpenAIRE

    Gaur, Sumit; Agnihotri, Rupali

    2012-01-01

    Phenobarbital, an antiepileptic agent has numerous adverse reactions including Stevens- Johnson syndrome (SJS), a rare medical emergency. A 12-year-old male epileptic child with phenobarbital-induced SJS was referred for the management of severe pain in relation to extensively decayed molar tooth and oral mucosal ulcerations. The patient was managed by withdrawal of phenobarbital and palliative treatment of the lesions.

  11. Finite Yang-Mills theories and the Bjorken--Johnson--Low limit

    International Nuclear Information System (INIS)

    Ali, A.; Bernstein, J.

    1975-01-01

    We consider the Bjorken-Johnson-Low limit for the propagator in massless Yang-Mills theories. The significance of our result in terms of imposing an eigenvalue on the theory so as to render it finite is discussed

  12. James Weldon Johnson and the Speech Lab Recordings

    Directory of Open Access Journals (Sweden)

    Chris Mustazza

    2016-03-01

    Full Text Available On December 24, 1935, James Weldon Johnson read thirteen of his poems at Columbia University, in a recording session engineered by Columbia Professor of Speech George W. Hibbitt and Barnard colleague Professor W. Cabell Greet, pioneers in the field that became sociolinguistics. Interested in American dialects, Greet and Hibbitt used early sound recording technologies to preserve dialect samples. In the same lab where they recorded T.S. Eliot, Gertrude Stein, and others, James Weldon Johnson read a selection of poems that included several from his seminal collection God’s Trombones and some dialect poems. Mustazza has digitized these and made them publicly available in the PennSound archive. In this essay, Mustazza contextualizes the collection, considering the recordings as sonic inscriptions alongside their textual manifestations. He argues that the collection must be heard within the frames of its production conditions—especially its recording in a speech lab—and that the sound recordings are essential elements in an hermeneutic analysis of the poems. He reasons that the poems’ original topics are reframed and refocused when historicized and contextualized within the frame of The Speech Lab Recordings.

  13. Drug‑induced Stevens–Johnson Syndrome in Indian Population: A ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... Drug-induced Stevens–Johnson syndrome in Indian population: A multicentric retrospective analysis. Niger J Clin Pract 2017;20:978-83. This is an open access article distributed under the terms of the Creative Commons. Attribution-Non Commercial-Share Alike 3.0 License, which allows others to remix,.

  14. Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs.

    Science.gov (United States)

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2011-04-01

    Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.

  15. Using Johnson Distribution for Automatic Threshold Setting in Wind Turbine Condition Monitoring System

    DEFF Research Database (Denmark)

    Marhadi, Kun Saptohartyadi; Skrimpas, Georgios Alexandros

    2014-01-01

    not rep- resent the whole operating conditions of a turbine, which re- sults in uncertainty in the parameters of the fitted probabil- ity distribution and the thresholds calculated. In this study Johnson distribution is used to identify shape, location, and scale parameters of distribution that can best...... fit vibration data. This study shows that using Johnson distribution can elim- inate testing or fitting various distributions to the data, and have more direct approach to obtain optimal thresholds. To quantify uncertainty in the thresholds due to limited data, im- plementations with bootstrap method...

  16. Stevens-Johnson Syndrome After Armodafinil Use.

    Science.gov (United States)

    Holfinger, Steven; Roy, Asim; Schmidt, Markus

    2018-05-15

    We present the case of a 21-year-old woman in whom Stevens-Johnson syndrome (SJS) developed after initiation of armodafinil. Although this rare and life-threatening reaction is listed on armodafinil's label, no cases have been reported in the literature. This case, in addition to an update of the drug's label after post-marketing research, both support the link between armodafinil and SJS. Providers should maintain a high clinical suspicion for SJS when starting therapy to minimize associated morbidity and mortality by discontinuing armodafinil at the onset of first symptoms. © 2018 American Academy of Sleep Medicine.

  17. Fostering Helping Relationships: An Interview with W. Brad Johnson

    Science.gov (United States)

    Johnson, W. Brad; Robison, Susan

    2017-01-01

    There are many kinds of helping relationships--coaching, mentoring, psychotherapy, and others. In this interview with W. Brad Johnson, Susan Robison explores how some of his insights about mentoring can be applicable to other types of helping relationships, like coaching. Mentoring is viewed as a broader relationship, but does include many of the…

  18. Yang--Mills gauge theories and Baker--Johnson quantum electrodynamics

    International Nuclear Information System (INIS)

    Lemmon, J.; Mahanthappa, K.T.

    1976-01-01

    We show that the physical mass of a fermion in a symmetric asymptotically free non-Abelian vector gauge theory is dynamical in origin. We comment on the close analogy that exists between such a theory and the Baker--Johnson finite quantum electrodynamics. Comments are also made when there is spontaneous symmetry breaking

  19. Development and Certification of Ultrasonic Background Noise Test (UBNT) System for use on the International Space Station (ISS)

    Science.gov (United States)

    Prosser, William H.; Madaras, Eric I.

    2011-01-01

    As a next step in the development and implementation of an on-board leak detection and localization system on the International Space Station (ISS), there is a documented need to obtain measurements of the ultrasonic background noise levels that exist within the ISS. This need is documented in the ISS Integrated Risk Management System (IRMA), Watch Item #4669. To address this, scientists and engineers from the Langley Research Center (LaRC) and the Johnson Space Center (JSC), proposed to the NASA Engineering and Safety Center (NESC) and the ISS Vehicle Office a joint assessment to develop a flight package as a Station Development Test Objective (SDTO) that would perform ultrasonic background noise measurements within the United States (US) controlled ISS structure. This document contains the results of the assessment

  20. Airports and Airfields, Airports within Johnson County as well as runway depicted with attribute information of both airport and runway., Published in Not Provided, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Airports and Airfields dataset current as of unknown. Airports within Johnson County as well as runway depicted with attribute information of both airport and runway..

  1. Fabrication of a mini multi-fixed-point cell for the calibration of industrial platinum resistance thermometers

    Science.gov (United States)

    Ragay-Enot, Monalisa; Lee, Young Hee; Kim, Yong-Gyoo

    2017-07-01

    A mini multi-fixed-point cell (length 118 mm, diameter 33 mm) containing three materials (In-Zn eutectic (mass fraction 3.8% Zn), Sn and Pb) in a single crucible was designed and fabricated for the easy and economical fixed-point calibration of industrial platinum resistance thermometers (IPRTs) for use in industrial temperature measurements. The melting and freezing behaviors of the metals were investigated and the phase transition temperatures were determined using a commercial dry-block calibrator. Results showed that the melting plateaus are generally easy to realize and are reproducible, flatter and of longer duration. On the other hand, the freezing process is generally difficult, especially for Sn, due to the high supercooling required to initiate freezing. The observed melting temperatures at optimum set conditions were 143.11 °C (In-Zn), 231.70 °C (Sn) and 327.15 °C (Pb) with expanded uncertainties (k  = 2) of 0.12 °C, 0.10 °C and 0.13 °C, respectively. This multi-fixed-point cell can be treated as a sole reference temperature-generating system. Based on the results, the realization of melting points of the mini multi-fixed-point cell can be recommended for the direct calibration of IPRTs in industrial applications without the need for a reference thermometer.

  2. Deviasi Taksiran Berat Janin pada Metode Johnson-Toshack, Formula Sederhana dan Formula Dare

    Directory of Open Access Journals (Sweden)

    Emy Rianti

    2017-08-01

    Full Text Available The ability of the birth attendant to estimate the birth weight of the fetus is very important that it does not cause childbirth dystocia that may cause rip in the birth canal. The aim of this study was to compare the deviation of fetal weight estimation according to Johnson-Toshack method, simple formula and Dare formula. Thedesign used was cross sectional, the data taken primarily, involving 100 respondents at Fatmawati General Hospital Jakarta, from August to September 2015. The findings showed that the smallest deviation mean of fetal weight estimation is Johnson-Toshack method. The results of this method of measurement tend to be close to infant birth weight, especially in the client childbirth with abdominal circumference 90 - 100 cm. The conclusion of this study is that Johnson-Toshack's fetal weighing estimates are more appropriate for childbirth with 90 to 100 cm abdominal circumference size, except in childbirth with ruptured membranes, applying a fetal weight estimate based on the Dare formula would be more appropriate.

  3. UNCERTAINTY AND THE JOHNSON-ETTINGER MODEL FOR VAPOR INTRUSION CALCULATIONS

    Science.gov (United States)

    The Johnson-Ettinger Model is widely used for assessing the impacts of contaminated vapors on residential air quality. Typical use of this model relies on a suite of estimated data, with few site-specific measurements. Software was developed to provide the public with automate...

  4. The Johnson Space Center management information systems: User's guide to JSCMIS

    Science.gov (United States)

    Bishop, Peter C.; Erickson, Lloyd

    1990-01-01

    The Johnson Space Center Management Information System (JSCMIS) is an interface to computer data bases at the NASA Johnson Space Center which allows an authorized user to browse and retrieve information from a variety of sources with minimum effort. The User's Guide to JSCMIS is the supplement to the JSCMIS Research Report which details the objectives, the architecture, and implementation of the interface. It is a tutorial on how to use the interface and a reference for details about it. The guide is structured like an extended JSCMIS session, describing all of the interface features and how to use them. It also contains an appendix with each of the standard FORMATs currently included in the interface. Users may review them to decide which FORMAT most suits their needs.

  5. Early-stage evolution of particle size distribution with Johnson's SB function due to Brownian coagulation

    International Nuclear Information System (INIS)

    Tang Hong; Lin Jianzhong

    2013-01-01

    The moment method can be used to determine the time evolution of particle size distribution due to Brownian coagulation based on the general dynamic equation (GDE). But the function form of the initial particle size distribution must be determined beforehand for the moment method. If the assumed function type of the initial particle size distribution has an obvious deviation from the true particle population, the evolution of particle size distribution may be different from the real evolution tendency. Thus, a simple and general method is proposed based on the moment method. In this method, the Johnson's S B function is chosen as a general distribution function to fit the initial distributions including the log normal (L-N), Rosin–Rammler (R-R), normal (N-N) and gamma distribution functions, respectively. Meanwhile, using the modified beta function to fit the L-N, R-R, N-N and gamma functions is also conducted as a comparison in order to present the advantage of the Johnson's S B function as the general distribution function. And then, the time evolution of particle size distributions using the Johnson's S B function as the initial distribution can be obtained by several lower order moment equations of the Johnson's S B function in conjunction with the GDE during the Brownian coagulation process. Simulation experiments indicate that fairly reasonable results of the time evolution of particle size distribution can be obtained with this proposed method in the free molecule regime, transition regime and continuum plus near continuum regime, respectively, at the early time stage of evolution. The Johnson's S B function has the ability of describing the early time evolution of different initial particle size distributions. (paper)

  6. International comparison of resistance thermometers between NMIs from Spain, Mexico and Andean countries

    Science.gov (United States)

    del Campo, D.; Ruiz, V. C.; Méndez-Lango, E.; Córdova, L.; von Borries, E.; Sánchez, C. A.; Arévalo, A.; Aguilera, B.; Guillén, E.; Cabrera, C.; Quintana, L.

    2013-09-01

    An international comparison on semi-standard Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Mexico and the Andean Countries (Bolivia, Colombia, Ecuador, Peru and Venezuela) began in 2004 and was successfully completed in 2005. Two PRTs were circulated (hand carried) and compared from -40 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, was the pilot laboratory and the Centro Nacional de Metrología (Mexican NMI), CENAM, was the co-pilot laboratory. This paper shows the details of the comparison and the final results as they were presented in the approved final report of the comparison in September of 2005.

  7. Water quality of streams in Johnson County, Kansas, 2002-07

    Science.gov (United States)

    Rasmussen, T.J.

    2009-01-01

    Water quality of streams in Johnson County, Kansas was evaluated from October 2002 through December 2007 in a cooperative study between the U.S. Geological Survey and the Johnson County Stormwater Management Program. Water quality at 42 stream sites, representing urban and rural basins, was characterized by evaluating benthic macroinvertebrates, water (discrete and continuous data), and/or streambed sediment. Point and nonpoint sources and transport were described for water-quality constituents including suspended sediment, dissolved solids and major ions, nutrients (nitrogen and phosphorus), indicator bacteria, pesticides, and organic wastewater and pharmaceutical compounds. The information obtained from this study is being used by city and county officials to develop effective management plans for protecting and improving stream quality. This fact sheet summarizes important results from three comprehensive reports published as part of the study and available on the World Wide Web at http://ks.water.usgs.gov/Kansas/studies/qw/joco/. ?? 2009 ASCE.

  8. A Theoretical Analysis of the Performance of Learning Disabled Students on the Woodcock-Johnson Psycho-Educational Battery.

    Science.gov (United States)

    Shinn, Mark; And Others

    Two studies were conducted to (1) analyze the subtest characteristics of the Woodcock-Johnson Psycho-Educational Battery, and (2) apply those results to an analysis of 50 fourth grade learning disabled (LD) students' performance on the Battery. Analyses indicated that the poorer performance of LD students on the Woodcock-Johnson Tests of Cognitive…

  9. Status and Monitoring of Natural and Supplemented Chinook Salmon in Johnson Creek, Idaho, 2006-2007 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Rabe, Craig D.; Nelson, Douglas D. [Nez Perce Tribe

    2008-11-17

    The Nez Perce Tribe Johnson Creek Artificial Propagation Enhancement Project (JCAPE) has conducted juvenile and adult monitoring and evaluation studies for its 10th consecutive year. Completion of adult and juvenile Chinook salmon studies were conducted for the purpose of evaluating a small-scale production initiative designed to increase the survival of a weak but recoverable spawning aggregate of summer Chinook salmon Oncorhynchus tshawytscha. The JCAPE program evaluates the life cycle of natural origin (NOR) and hatchery origin (HOR) supplementation fish to quantify the key performance measures: abundance, survival-productivity, distribution, genetics, life history, habitat, and in-hatchery metrics. Operation of a picket style weir and intensive multiple spawning ground surveys were completed to monitor adult Chinook salmon and a rotary screw trap was used to monitor migrating juvenile Chinook salmon in Johnson Creek. In 2007, spawning ground surveys were conducted on all available spawning habitat in Johnson Creek and one of its tributaries. A total of 63 redds were observed in the index reach and 11 redds for all other reaches for a combined count of 74 redds. Utilization of carcass recovery surveys and adult captures at an adult picket weir yielded a total estimated adult escapement to Johnson Creek of 438 Chinook salmon. Upon deducting fish removed for broodstock (n=52), weir mortality/ known strays (n=12), and prespawning mortality (n=15), an estimated 359 summer Chinook salmon were available to spawn. Estimated total migration of brood year 2005 NOR juvenile Chinook salmon at the rotary screw trap was calculated for three seasons (summer, fall, and spring). The total estimated migration was 34,194 fish; 26,671 of the NOR migrants left in the summer (July 1 to August 31, 2005) as fry/parr, 5,852 left in the fall (September 1 to November 21, 2005) as presmolt, and only 1,671 NOR fish left in the spring (March 1 to June 30, 2006) as smolt. In addition, there

  10. 77 FR 63873 - Johnson Controls, Inc. Including On-Site Leased Workers of Valley Staffing and AZ Quality Hudson...

    Science.gov (United States)

    2012-10-17

    ... workers of Johnson Controls, Inc., including on-site leased workers from Valley Staffing, Hudson..., Wisconsin location of Johnson Controls, Inc. The Department has determined that these workers were sufficiently under the control of the subject firm to be considered leased workers. Based on these findings...

  11. Spaceflight Radiation Health program at the Lyndon B. Johnson Space Center

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, A.S.; Badhwar, G.D.; Golightly, M.J.; Hardy, A.C.; Konradi, A.; Yang, T.C.

    1993-12-01

    The Johnson Space Center leads the research and development activities that address the health effects of space radiation exposure to astronaut crews. Increased knowledge of the composition of the environment and of the biological effects of space radiation is required to assess health risks to astronaut crews. The activities at the Johnson Space Center range from quantification of astronaut exposures to fundamental research into the biological effects resulting from exposure to high energy particle radiation. The Spaceflight Radiation Health Program seeks to balance the requirements for operational flexibility with the requirement to minimize crew radiation exposures. The components of the space radiation environment are characterized. Current and future radiation monitoring instrumentation is described. Radiation health risk activities are described for current Shuttle operations and for research development program activities to shape future analysis of health risk.

  12. Spaceflight Radiation Health program at the Lyndon B. Johnson Space Center

    International Nuclear Information System (INIS)

    Johnson, A.S.; Badhwar, G.D.; Golightly, M.J.; Hardy, A.C.; Konradi, A.; Yang, T.C.

    1993-12-01

    The Johnson Space Center leads the research and development activities that address the health effects of space radiation exposure to astronaut crews. Increased knowledge of the composition of the environment and of the biological effects of space radiation is required to assess health risks to astronaut crews. The activities at the Johnson Space Center range from quantification of astronaut exposures to fundamental research into the biological effects resulting from exposure to high energy particle radiation. The Spaceflight Radiation Health Program seeks to balance the requirements for operational flexibility with the requirement to minimize crew radiation exposures. The components of the space radiation environment are characterized. Current and future radiation monitoring instrumentation is described. Radiation health risk activities are described for current Shuttle operations and for research development program activities to shape future analysis of health risk

  13. Danish resonances and repercussions in the life and work of William H. Johnson

    DEFF Research Database (Denmark)

    Sørensen, Bent

    William H. Johnson was an outstanding African-American artist, represented with hundreds of works in the Smithsonian Museum of American Art’s collection, but he was also a resident of Denmark for the better part of the 1930s, and again for a brief spell after WWII. While studying art in Paris...... and the rest of Scandinavia in that period. I shall take a look at the reception of his work (and that of Holcha Krake) in all three Scandinavian countries (they both spent considerable time in Norway and Sweden as well as in Holcha’s native Denmark) which routinely exoticizes Johnson and his art in language...

  14. Power decoding Reed-Solomon codes up to the Johnson radius

    DEFF Research Database (Denmark)

    Rosenkilde, Johan Sebastian Heesemann

    2018-01-01

    Power decoding, or "decoding using virtual interleaving" is a technique for decoding Reed-Solomon codes up to the Sudan radius. Since the method's inception, it has been an open question if it is possible to use this approach to decode up to the Johnson radius - the decoding radius of the Guruswami...

  15. A Field Assessment of a Prototype Meter for Measuring the Wet-Bulb Globe-Thermometer Index

    Science.gov (United States)

    Walters, J. D.

    1968-01-01

    A prototype electronic instrument for the direct measurement of the wet-bulb globe-thermometer index is described. An assessment is made of its accuracy, as compared with W.B.G.T. indices calculated from conventional thermometric data, and a comparison is made between W.B.G.T. values read from the meter and effective or corrected effective temperatures derived from separate thermometric and air velocity recording instruments in the same climates. The instrument proved to be reliable and accurate over a wide range of climates and is a useful self-contained device for use in habitability surveys and similar investigations. Images PMID:5663429

  16. 77 FR 9969 - Johnson Controls D/B/A Hoover Universal, Inc. Including On-Site Leased Workers from Kelly...

    Science.gov (United States)

    2012-02-21

    ... Johnson Controls, including on-site leased workers from Kelly Services, Sycamore, Illinois. The notice was... amended notice applicable to TA-W-73,074 is hereby issued as follows: ''All workers of Johnston Controls... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,074] Johnson Controls D/B/A...

  17. Scott Morgan Johnson Middle School: Personalization Leads to Unlimited Success

    Science.gov (United States)

    Principal Leadership, 2013

    2013-01-01

    The well-known lyrics may be "The Eyes of Texas Are Upon You," but at Scott Morgan Johnson Middle School in McKinney, TX, it's definitely the "eye of the tiger" that sets the bar for Tiger PRIDE (perseverance, respect, integrity, determination, and excellence). This article describes how those ideals have been infused…

  18. Development of a noise-based method for the determination of the moderator temperature coefficient of reactivity (MTC) in pressurized water reactors (PWRs)

    International Nuclear Information System (INIS)

    Demaziere, C.

    2002-01-01

    The Moderator Temperature Coefficient of reactivity (MTC) is an important safety parameter of Pressurized Water Reactors (PWRs). In most countries, the so-called at-power MTC has to be measured a few months before the reactor outage, in order to determine if the MTC will not become too negative. Usually, the at-power MTC is determined by inducing a change in the moderator temperature, which has to be compensated for by other means, such as a change in the boron concentration. An MTC measurement using the boron dilution method is analysed in this thesis. It is demonstrated that the uncertainty of such a measurement technique is so large, that the measured MTC could become more negative than what the Technical Specifications allow. Furthermore, this technique incurs a disturbance of the plant operation. For this reason, another technique relying on noise analysis was proposed a few years ago. In this technique, the MTC is inferred from the neutron noise measured inside the core and the moderator temperature noise measured at the core-exit, in the same or in a neighbouring fuel assembly. This technique does not require any perturbation of the reactor operation, but was nevertheless proven to underestimate the MTC by a factor of 2 to 5. In this thesis, it is shown, both theoretically and experimentally, that the reason of the MTC underestimation by noise analysis is the radially loosely coupled character of the moderator temperature noise throughout the core. A new MTC noise estimator, accounting for this radially non-homogeneous moderator temperature noise is proposed and demonstrated to give the correct MTC value. This new MTC noise estimator relies on the neutron noise measured in a single point of the reactor and the radially averaged moderator temperature noise measured inside the core. In the case of the Ringhals-2 PWR in Sweden, Gamma-Thermometers (GTs) offer such a possibility since in dynamic mode they measure the moderator temperature noise, whereas in static

  19. A 6-bit 4 GS/s pseudo-thermometer segmented CMOS DAC

    Science.gov (United States)

    Yijun, Song; Wenyuan, Li

    2014-06-01

    A 6-bit 4 GS/s, high-speed and power-efficient DAC for ultra-high-speed transceivers in 60 GHz band millimeter wave technology is presented. A novel pseudo-thermometer architecture is proposed to realize a good compromise between the fast conversion speed and the chip area. Symmetrical and compact floor planning and layout techniques including tree-like routing, cross-quading and common-centroid method are adopted to guarantee the chip is fully functional up to near-Nyquist frequency in a standard 0.18 μm CMOS process. Post simulation results corroborate the feasibility of the designed DAC, which canperform good static and dynamic linearity without calibration. DNL errors and INL errors can be controlled within ±0.28 LSB and ±0.26 LSB, respectively. SFDR at 4 GHz clock frequency for a 1.9 GHz near-Nyquist sinusoidal output signal is 40.83 dB and the power dissipation is less than 37 mW.

  20. A 6-bit 4 GS/s pseudo-thermometer segmented CMOS DAC

    International Nuclear Information System (INIS)

    Song Yijun; Li Wenyuan

    2014-01-01

    A 6-bit 4 GS/s, high-speed and power-efficient DAC for ultra-high-speed transceivers in 60 GHz band millimeter wave technology is presented. A novel pseudo-thermometer architecture is proposed to realize a good compromise between the fast conversion speed and the chip area. Symmetrical and compact floor planning and layout techniques including tree-like routing, cross-quading and common-centroid method are adopted to guarantee the chip is fully functional up to near-Nyquist frequency in a standard 0.18 μm CMOS process. Post simulation results corroborate the feasibility of the designed DAC, which canperform good static and dynamic linearity without calibration. DNL errors and INL errors can be controlled within ±0.28 LSB and ±0.26 LSB, respectively. SFDR at 4 GHz clock frequency for a 1.9 GHz near-Nyquist sinusoidal output signal is 40.83 dB and the power dissipation is less than 37 mW. (semiconductor integrated circuits)

  1. Noise suppression by noise

    OpenAIRE

    Vilar, J. M. G. (José M. G.), 1972-; Rubí Capaceti, José Miguel

    2001-01-01

    We have analyzed the interplay between an externally added noise and the intrinsic noise of systems that relax fast towards a stationary state, and found that increasing the intensity of the external noise can reduce the total noise of the system. We have established a general criterion for the appearance of this phenomenon and discussed two examples in detail.

  2. Does Johnson's Prescriptive Approach Still Have a Role to Play in ...

    African Journals Online (AJOL)

    Samuel Johnson's dictionary (1755) confirmed both the status of dictionaries as authoritative sources of (linguistic) knowledge and the prescriptive approach in lexicography. This approach prevailed for a long time. During the last decades the descriptive approach came to the fore, aptly supported by the increased reliance ...

  3. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.

    Science.gov (United States)

    Kongpanichkul, A; Bunjongpak, S

    2000-09-01

    This study was carried out to assess the accuracy of three devices namely, liquid crystal forehead, digital electronic axillary and infrared tympanic thermometer, using a glass-mercury rectal thermometer as the control. The subjects were two hundred children aged 0-48 months. The mean rectal temperature was 38.0 +/- 0.91 degrees C; forehead, 37.83 +/- 0.94 degrees C; tympanic, 37.77 +/- 0.95 degrees C, and axillary, 37.71 +/- 0.86 degrees C. Compared to the rectal temperature, all values were significantly lower (p < 0.05). Forehead, tympanic and axillary temperature differed from rectal temperature by at least 0.5 degrees C in 33.33 per cent, 23.5 per cent and 31.5 per cent of subjects, and at least 1 degrees C in 22 per cent, 1 per cent and 6 per cent of subjects respectively. Accuracy in detection of fever was 79 per cent for forehead, 85.5 per cent for tympanic and 84 per cent for axillary thermometry. Sensitivity of the three devices was 67-83 per cent in detection of fever and 64-77 per cent in detection of high fever. Tympanic thermometry had the best performance while forehead thermometry had the poorest. After using revised diagnostic threshold temperature by ROC curves, sensitivity of each device improved but accuracy was nearly the same. It is concluded that the three devices are not suitable as a substitute for a glass-mercury rectal thermometer in assessment of fever in infants and young children.

  4. DOES BRAND EXTENSION IMPACT PARENT BRAND: A CASE OF JOHNSON, UK

    Directory of Open Access Journals (Sweden)

    Muhammad Shakil AHMAD

    2011-01-01

    Full Text Available Purpose of study: The main purpose of this study is to check the impact ofbrand extensions on brand image. For this purpose Johnson is selected asparent brand for current research. The targeted brand extensions areJohnson shampoo, Johnson’s isotonic drinks, Johnson’s sports wear andJohnson’s suntan lotion. Research Methodology: sample was selected fromBradford, UK. Sample consists of graduate students including males as wellas female. Total sample size is 60 and data was collected through selfadministered questionnaires. For each brand 15 respondents were selected.Convenient sampling was selected as sampling technique. Results: Resultsshow that Johnson’s have high brand awareness and perceived quality.While there is negative correlation results for brand fit on brand image forthose product extensions which are not in same brand category i.e.Johnson’s sportswear and Johnson’s isotonic drinks. Conclusion: It isconcluded from study results that launching new product in same parentbrand category have high chance of success while in different category isrisk.

  5. Are steroids effective in toxic epidermal necrolysis and Stevens-Johnson syndrome?

    Directory of Open Access Journals (Sweden)

    Rodrigo Meza

    2017-06-01

    Full Text Available Resumen La necrólisis epidérmica tóxica y el síndrome de Stevens-Johnson son reacciones cutáneas adversas graves a medicamentos e infecciones. Los corticoides se describen como una alternativa terapéutica, sin embargo, su uso es aún controvertido. Utilizando la base de datos Epistemonikos, la cual es mantenida mediante búsquedas en múltiples bases de datos, identificamos cuatro revisiones sistemáticas que en conjunto incluyen once estudios primarios que responden la pregunta de interés. Extrajimos los datos y preparamos una tabla de resumen de los resultados utilizando el método GRADE. Concluimos que no está claro si los corticoides disminuyen la mortalidad o la estadía hospitalaria en la necrólisis epidérmica tóxica y el síndrome de Stevens-Johnson porque la certeza de la evidencia es muy baja.

  6. Elfin butterflies of the genus Rhamma Johnson (Lepidoptera: Lycaenidae: Theclinae): A review of the Colombian species.

    Science.gov (United States)

    Prieto, Carlos; Vargas, Maria A

    2016-03-22

    The Colombian species of the genus Rhamma Johnson, 1992 are revised. Male and female phenotypes of all species are associated and diagnosed, and data on their distributions are given along with a discussion of the geographic variability of the species. Thirteen taxa are considered valid at the species level. The following taxonomic changes are proposed: Rhamma andradei (Le Crom & Johnson), stat. nov, comb. nov.; previously considered a nomen dubium in Penaincisalia Johnson, the taxon is considered a valid species of Rhamma. The placement of Rhamma anosma (Draudt), comb. nov., described as Thecla, is confirmed as belonging to Rhamma. A lectotype is designated for Thecla mishma Hewitson, 1878. Adults, male and female genitalia, and distribution maps are depicted for all species, along with an identification key based on adults.

  7. Stevens-Johnson syndrome associated with Malarone antimalarial prophylaxis.

    Science.gov (United States)

    Emberger, Michael; Lechner, Arno Michael; Zelger, Bernhard

    2003-07-01

    To the best of our knowledge, Stevens-Johnson syndrome (SJS) has not been reported previously as an adverse reaction to Malarone, which is a combination of atovaquone and proguanil hydrochloride used for antimalarial prophylaxis and therapy. We describe a 65-year-old patient who had SJS with typical clinical and histopathological findings associated with the use of Malarone prophylaxis for malaria. This report should alert physicians to this severe cutaneous reaction, and Malarone should be added to the list of drugs that can potentially cause SJS.

  8. Dealing with the size-of-source effect in the calibration of direct-reading radiation thermometer

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, P. [Measurement Standards Laboratory of New Zealand, PO Box 31-310, Lower Hutt 5040 (New Zealand)

    2013-09-11

    The majority of general-purpose low-temperature handheld radiation thermometers are severely affected by the size-of-source effect (SSE). Calibration of these instruments is pointless unless the SSE is accounted for in the calibration process. Traditional SSE measurement techniques, however, are costly and time consuming, and because the instruments are direct-reading in temperature, traditional SSE results are not easily interpretable, particularly by the general user. This paper describes a simplified method for measuring the SSE, suitable for second-tier calibration laboratories and requiring no additional equipment, and proposes a means of reporting SSE results on a calibration certificate that should be easily understood by the non-specialist user.

  9. Magnetic Criticality Enhanced Hybrid Nanodiamond Thermometer under Ambient Conditions

    Science.gov (United States)

    Wang, Ning; Liu, Gang-Qin; Leong, Weng-Hang; Zeng, Hualing; Feng, Xi; Li, Si-Hong; Dolde, Florian; Fedder, Helmut; Wrachtrup, Jörg; Cui, Xiao-Dong; Yang, Sen; Li, Quan; Liu, Ren-Bao

    2018-01-01

    Nitrogen-vacancy (NV) centers in diamond are attractive as quantum sensors owing to their superb coherence under ambient conditions. However, the NV center spin resonances are relatively insensitive to some important parameters such as temperature and pressure. Here we design and experimentally demonstrate a hybrid nanothermometer composed of NV centers and a magnetic nanoparticle (MNP), in which the temperature sensitivity is enhanced by the critical magnetization of the MNP near the ferromagnetic-paramagnetic transition temperature. The temperature susceptibility of the NV center spin resonance reaches 14 MHz /K , nearly 200 times larger than that of bare NV centers. The sensitivity of a hybrid nanothermometer composed of a Cu1 -xNix MNP and a nanodiamond is measured to be 11 mK /√{Hz } under ambient conditions. The working range of the hybrid thermometer can be designed from cryogenic temperature to about 600 K by tuning the chemical composition of the Cu1 -xNix MNP. We demonstrate in situ detection of the magnetic phase transition of a single magnetic nanoparticle using the hybrid nanothermometer. This hybrid nanothermometer provides a novel approach to studying a broad range of thermal processes at nanoscales such as nanoplasmonics, heat-stimulated subcellular processes, and thermodynamics of nanosystems.

  10. Magnetic Criticality Enhanced Hybrid Nanodiamond Thermometer under Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Ning Wang

    2018-03-01

    Full Text Available Nitrogen-vacancy (NV centers in diamond are attractive as quantum sensors owing to their superb coherence under ambient conditions. However, the NV center spin resonances are relatively insensitive to some important parameters such as temperature and pressure. Here we design and experimentally demonstrate a hybrid nanothermometer composed of NV centers and a magnetic nanoparticle (MNP, in which the temperature sensitivity is enhanced by the critical magnetization of the MNP near the ferromagnetic-paramagnetic transition temperature. The temperature susceptibility of the NV center spin resonance reaches 14  MHz/K, nearly 200 times larger than that of bare NV centers. The sensitivity of a hybrid nanothermometer composed of a Cu_{1-x}Ni_{x} MNP and a nanodiamond is measured to be 11  mK/sqrt[Hz] under ambient conditions. The working range of the hybrid thermometer can be designed from cryogenic temperature to about 600 K by tuning the chemical composition of the Cu_{1-x}Ni_{x} MNP. We demonstrate in situ detection of the magnetic phase transition of a single magnetic nanoparticle using the hybrid nanothermometer. This hybrid nanothermometer provides a novel approach to studying a broad range of thermal processes at nanoscales such as nanoplasmonics, heat-stimulated subcellular processes, and thermodynamics of nanosystems.

  11. Operational methods of thermodynamics. Volume 1 - Temperature measurement

    Science.gov (United States)

    Eder, F. X.

    The principles of thermometry are examined, taking into account the concept of temperature, the Kelvin scale, the statistical theory of heat, negative absolute temperatures, the thermodynamic temperature scale, the thermodynamic temperature scale below 1 K, noise thermometry, temperature scales based on black-body radiation, acoustical thermometry, and the International Practical Temperature Scale 1968. Aspects of practical temperature measurement are discussed, giving attention to thermometers based on the expansion of a gas or a liquid, instruments utilizing the relative thermal expansion of two different metals, devices measuring the vapor pressure of a liquid, thermocouples, resistance thermometers, radiation pyrometers of various types, instruments utilizing the temperature dependence of a number of material characteristics, devices for temperature control, thermometer calibration, and aspects of thermometer installation and inertia. A description is presented of the approaches employed for the measurement of low temperatures.

  12. County and Parish Boundaries, This was created and maintained by Johnson County Records and Tax Administration and is updated when changes occur to county boundaries, Published in 2007, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — County and Parish Boundaries dataset current as of 2007. This was created and maintained by Johnson County Records and Tax Administration and is updated when changes...

  13. Income and Democracy: A Comment on Acemoglu, Johnson, Robinson, and Yared (2008)

    DEFF Research Database (Denmark)

    Paldam, Martin; Gundlach, Erich

    Acemoglu, Johnson, Robinson, and Yared (2008) demonstrate that estimation of the standard adjustment model with country-fixed and time-fixed effects removes the statistical significance of income as a causal factor of democracy. We argue that their empirical approach must produce insignificant...

  14. Employment, Salary & Placement Information for Johnson County Community College Career Programs.

    Science.gov (United States)

    Conklin, Karen A.

    More than forty-six career programs are offered at Johnson County Community College (JCCC) in Kansas, in such areas as Cosmetology, Dental Assistance, and Travel and Tourism. These programs specialize in the types of industries that are currently growing at high rates, such as computer-related occupations and special education teachers. This…

  15. STEVENS–JOHNSON SYNDROME — TOXIC EPIDERMAL NECTROLYSIS IN CHILDREN. PART II. SYSTEM, LOCAL TREATMENT

    Directory of Open Access Journals (Sweden)

    V.F. Zhernosek

    2011-01-01

    Full Text Available The second part of the article concerning Stevens–Johnson syndrome — toxic epidermal necrolysis (SJS–TEN is devoted to the treatment of this disease. The modern approaches to the use of systemic agents — antibacterial, antiviral, analgesics and sedatives, and anticoagulants are discussed in detail. Regulations of the drugs use depending on the patient state and the etiology of SJS–TEN are marked out. The basic principles of the fluid therapy for rehydration and dehydration prevention are shown in the article. Particular attention is paid to the local therapy — treatment of mucous membranes and skin lesions.Key words: Stevens-Johnson syndrome, toxic epidermal necrolysis, children, antibiotic therapy, topical treatment.

  16. Pediatric Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Halted by Etanercept.

    Science.gov (United States)

    Gavigan, Geneviève M; Kanigsberg, Nordau D; Ramien, Michele L

    2018-02-01

    We report a case of an 11-year-old female with Stevens-Johnson syndrome (SJS)/toxic epidermal necrolysis (TEN) overlap, most likely triggered by sulfamethoxazole-trimethoprim, who was treated with the combination of methylprednisolone, cyclosporine, and etanercept. Her condition stabilized and her skin involvement did not progress after the addition of etanercept. To our knowledge, this is the first report of etanercept for pediatric SJS/TEN.

  17. Folded diagram theory, time-dependent approach of Johnson and Baranger

    International Nuclear Information System (INIS)

    Johnson, M.B.

    1975-01-01

    The folded diagram expansion of Brandow and extensively developed by Johnson and Baranger is discussed in detail. The time-dependent approach is reviewed through Feynman-Goldstone diagrams to establish the conventions used. The problem of calculating the effective interaction for nuclei beyond 208 Pb is then considered as an example. Finally, examples are given which show how to do the time integrations. (17 figures) (SDF)

  18. Taxonomic revision of the afrotropical genus Megatrigon Johnson, 1898 (Diptera: Syrphidae)

    DEFF Research Database (Denmark)

    Doczkal, Dieter; Radenković, Snežana; Lyneborg, Leif

    2016-01-01

    The genus-group taxon Megatrigon Johnson, 1898, stat. nov., is revised and treated as a valid genus within the Merodontini (= Eumerini). Extensive diagnoses are given for the genus and for its three constituent species groups: argenteus group [11 spp.], nivalis group [monotypic], sexfasciatus group...

  19. The relationship between seismicity and wastewater injection in Johnson County, TX

    Science.gov (United States)

    Lee, S. S.; Walter, J. I.; Frohlich, C.; DeShon, H. R.

    2015-12-01

    In light of recent research that suggests some high-rate wastewater injection wells from commercial oil and gas operations are casually linked to recent earthquakes in North Texas and Oklahoma, we apply a waveform cross-correlation technique to continuous waveform data from 38 seismic stations across Texas and Oklahoma using templates from 96 cataloged events from 2010-2015. We focus on an area near Venus TX, 40 km south of the Dallas-Fort Worth metropolitan area in Johnson County where a M4.0 earthquake was reported by the USGS on 7 May 2015. The epicenter was within several km of 4 high rate wells with max injection rates ranging between 684,000-833,000 barrels/month. Templates were chosen from the USGS and locally derived Venus aftershock sequence, events in the ANSS catalog with a minimum magnitude of 2 between 2009-2015, and previously located earthquakes recorded by USArray stations between 2009-2011. In Johnson County, there are 27 wastewater injection wells, each with a reported maximum injection rate of 104,000 barrels/month and greater. We detected 494 events within Johnson and adjacent counties, with approximately 36% of the detections occurring within 10 km of the Venus earthquake, spanning March 2010 to June 2015. Most of the seismicity occurs adjacent to higher rate injection wells, suggesting a link between monthly injection rate and earthquake occurrence. Template matching allows us to detect earthquakes otherwise too small to be picked up by routine earthquake identification methods and informs our research concerning the presence and spatial distribution of possibly induced, small magnitude earthquakes. We plan to apply this technique to detect seismicity that may have occurred prior to the start of wastewater injection or felt earthquakes.

  20. Washington State Johnson-O'Malley Indian Education. 1971-72 Annual Report.

    Science.gov (United States)

    Washington Office of the State Superintendent of Public Instruction, Olympia.

    The Johnson-O'Malley (JOM) Act of 1934, amended in 1936, authorizes the Secretary of Interior to enter into a contract with any state which has legal authority and responsibility for the education of American Indian children residing there. The Superintendent of Public Instruction, State of Washington, is legally responsible for state schools and…

  1. Testing a Threshold: An Approximate Replication of Johnson, Mercado & Acevedo 2012

    Science.gov (United States)

    Johnson, Mark D.; Nicodemus, Christine L.

    2016-01-01

    In order to better understand the role of working memory in second language (L2) written production, this study contributes to recent research attempting to apply Kellogg's model of working memory in first language (L1) writing to L2 writing research (Ellis & Yuan 2004; Ong & Zhang 2010; Johnson, Mercado & Acevedo 2012). This paper…

  2. Innovative signal processing for Johnson Noise thermometry

    Energy Technology Data Exchange (ETDEWEB)

    Ezell, N. Dianne Bull [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Britton, Jr, Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Roberts, Michael [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

  3. Dialéctica material Donald Judd y Philip Johnson

    Directory of Open Access Journals (Sweden)

    María Teresa Muñoz

    2016-05-01

    Full Text Available Resumen El objetivo de este escrito es examinar cómo se plantea una cierta dialéctica material en el conjunto llamado la Mansana de Chinati, construido por el escultor Donald Judd en la ciudad de Marfa, Texas, a partir del año 1974, comparándolo con las dos viviendas que realiza el arquitecto Philip Johnson en su propiedad de New Canaan, Connecticut, en torno al año 1950. Tanto en New Canaan como en la Mansana de Chinati existe una  oposición, una dialéctica, entre una arquitectura industrial y otra artesana, tanto Philip Johnson como Donald Judd consideran que existe una arquitectura principal, la realizada con materiales y técnicas industriales, y otra subalterna o de servicio, la construida con piezas de arcilla y técnicas artesanales. Esta segunda arquitectura encarnará las cualidades asociadas con la pobreza, la abundancia material y la clausura espacial. Sin  embargo, esta exhibición de pobreza no tiene como fin los propios edificios domésticos construidos artesanalmente, ya sea con adobe o con ladrillo, sino que estará al servicio de esa otra arquitectura, construida con técnicas industriales, a la que se exige renunciar a la comodidad y el confort o cuando menos ocultarlos bajo la forma de una radical austeridad.

  4. Effects of background noise on total noise annoyance

    Science.gov (United States)

    Willshire, K. F.

    1987-01-01

    Two experiments were conducted to assess the effects of combined community noise sources on annoyance. The first experiment baseline relationships between annoyance and noise level for three community noise sources (jet aircraft flyovers, traffic and air conditioners) presented individually. Forty eight subjects evaluated the annoyance of each noise source presented at four different noise levels. Results indicated the slope of the linear relationship between annoyance and noise level for the traffic noise was significantly different from that of aircraft and of air conditioner noise, which had equal slopes. The second experiment investigated annoyance response to combined noise sources, with aircraft noise defined as the major noise source and traffic and air conditioner noise as background noise sources. Effects on annoyance of noise level differences between aircraft and background noise for three total noise levels and for both background noise sources were determined. A total of 216 subjects were required to make either total or source specific annoyance judgements, or a combination of the two, for a wide range of combined noise conditions.

  5. Stevens-Johnson syndrome associated with antimicrobial agent

    Directory of Open Access Journals (Sweden)

    Ivo Cavalcanti Pita Neto

    2008-01-01

    Full Text Available Among the severe reactions to medications, immune-mediated Mucocutaneous Disorders are widely represented. Steven-Johnson’s syndrome, or great multiform erythema, appears as a systemic disturbance, involving the skin and mucous membranes, and is related to several factors, such as, viral or bacterial infections and particularly the administration of medicines, in general painkillers and antibiotics. The objective of this article is report the onset of ulcerative vesicle –blister lesions in the regions of the lips, gums, tongue and genital mucosa membrane in a 26 year-old patient, a leukoderm man, being treated with sulfamethoxazole trimethoprim for a respiratory infection, after being diagnosed as having the Steven-Johnson syndrome. SSJ1 558187121279.

  6. 78 FR 19017 - Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey Pharmaceutical...

    Science.gov (United States)

    2013-03-28

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances; Notice of Application; Johnson Matthey Pharmaceutical Materials, Inc. Pursuant to Sec. 1301.33(a), Title... Matthey Pharmaceutical Materials, Inc., Pharmaceutical Service, 25 Patton Road, Devens, Massachusetts...

  7. Editing for performance: Dr Johnson and the stage Editing for performance: Dr Johnson and the stage

    Directory of Open Access Journals (Sweden)

    Peter Hollland

    2008-04-01

    Full Text Available I want to begin by quoting one of Dr Johnson’s notes on Hamlet, a passage that, though entirely characteristic, may be less than familiar to many. Johnson is commenting on the punctuation of a passage and is concerned about a sequence of dashes towards the end of the play: To a literary friend of mine I am indebted for the following very acute observation: “Throughout this play,” says he, “there is nothing more beautiful than these dashes; by their gradual elongation, they distinctly mark the balbuciation and the increasing difficulty of utterance observable in a dying man.” To which let me add, that, although dashes are in frequent use with our tragic poets, yet they are seldom introduced with so good an effect as in the present instance. (qtd. in Wells 1: 69 Johnson’s reliance on others—and their cloaked identity—is something we are used to. So too Johnson’s yearning here both to generalize about tragic practice and to praise the particular local effect in Shakespeare can be paralleled frequently elsewhere. I want to begin by quoting one of Dr Johnson’s notes on Hamlet, a passage that, though entirely characteristic, may be less than familiar to many. Johnson is commenting on the punctuation of a passage and is concerned about a sequence of dashes towards the end of the play: To a literary friend of mine I am indebted for the following very acute observation: “Throughout this play,” says he, “there is nothing more beautiful than these dashes; by their gradual elongation, they distinctly mark the balbuciation and the increasing difficulty of utterance observable in a dying man.” To which let me add, that, although dashes are in frequent use with our tragic poets, yet they are seldom introduced with so good an effect as in the present instance. (qtd. in Wells 1: 69 Johnson’s reliance on others—and their cloaked identity—is something we are used to. So too Johnson’s yearning here both to

  8. Temperature and other data were collected using thermometer and bottle casts in the Chukchi and Bering Sea from 1947-02-11 to 1949-07-26 (NODC Accession 9700081)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature, depth, oxygen, and salinity data were collected using thermometer and bottle casts from the USS CACOPAN, USS NEREUS, and HMCS CEDARWOOD in the Chukchi...

  9. Maximizing noise energy for noise-masking studies.

    Science.gov (United States)

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  10. A monocrystal of 59Co as a nuclear orientation thermometer in neutron experiments with oriented targets

    International Nuclear Information System (INIS)

    Fasoli, U.; Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.

    1980-01-01

    An apparatus for measuring temperatures in the millikelvin region is described based on the 'deformation effect' on fast neutron transmission through an aligned 59 Co monocrystal, employing a 252 Cf pill as the neutron source. A statistical accuracy of a few percent in a few minutes is obtainable with a heat input of some tens of pW. The apparatus is suitable in neutron experiments with oriented targets when the gamma-ray background hinders the use of gamma-ray anisotropy thermometers. In these and similar cases, in which the temperature must be held constant for long periods, the large heat capacity of the cobalt sample is not a drawback. (orig.)

  11. Active Noise Control for Dishwasher noise

    Science.gov (United States)

    Lee, Nokhaeng; Park, Youngjin

    2016-09-01

    The dishwasher is a useful home appliance and continually used for automatically washing dishes. It's commonly placed in the kitchen with built-in style for practicality and better use of space. In this environment, people are easily exposed to dishwasher noise, so it is an important issue for the consumers, especially for the people living in open and narrow space. Recently, the sound power levels of the noise are about 40 - 50 dBA. It could be achieved by removal of noise sources and passive means of insulating acoustical path. For more reduction, such a quiet mode with the lower speed of cycle has been introduced, but this deteriorates the washing capacity. Under this background, we propose active noise control for dishwasher noise. It is observed that the noise is propagating mainly from the lower part of the front side. Control speakers are placed in the part for the collocation. Observation part of estimating sound field distribution and control part of generating the anti-noise are designed for active noise control. Simulation result shows proposed active noise control scheme could have a potential application for dishwasher noise reduction.

  12. NASA Pathways Co-op Tour Johnson Space Center Fall 2013

    Science.gov (United States)

    Masood, Amir; Osborne-Lee, Irwin W.

    2013-01-01

    This report outlines the tasks and objectives completed during a co-operative education tour with National Aeronautics and Space Association (NASA) at the Johnson Space Center in Houston, Texas. I worked for the Attitude & Pointing group of the Flight Dynamics Division within the Mission Operations Directorate at Johnson Space Center. NASA's primary mission is to support and expand the various ongoing space exploration programs and any research and development activities associated with it. My primary project required me to develop and a SharePoint web application for my group. My secondary objective was to become familiar with the role of my group which was primarily to provide spacecraft attitude and line of sight determination, including Tracking and Data Relay Satellite (TDRS) communications coverage for various NASA, International, and commercial partner spacecraft. My projects required me to become acquainted with different software systems, fundamentals of aerospace engineering, project management, and develop essential interpersonal communication skills. Overall, I accomplished multiple goals which included laying the foundations for an updated SharePoint which will allow for an organized platform to communicate and share data for group members and external partners. I also successfully learned about the operations of the Attitude & Pointing Group and how it contributes to the Missions Operations Directorate and NASA's Space Program as a whole

  13. 77 FR 16264 - Manufacturer of Controlled Substances, Notice of Registration; Johnson Matthey Pharmaceutical...

    Science.gov (United States)

    2012-03-20

    ..., Notice of Registration; Johnson Matthey Pharmaceutical Materials Inc. By Notice dated November 18, 2011... Pharmaceutical Materials Inc., Pharmaceutical Service, 25 Patton Road, Devens, Massachusetts 01434, made... Matthey Pharmaceutical Materials Inc. to manufacture the listed basic classes of controlled substances is...

  14. Hydrogeology and simulation of ground-water flow in the Silurian-Devonian aquifer system, Johnson County, Iowa

    Science.gov (United States)

    Tucci, Patrick; McKay, Robert M.

    2006-01-01

    Bedrock of Silurian and Devonian age (termed the “Silurian-Devonian aquifer system”) is the primary source of ground water for Johnson County in east-central Iowa. Population growth within municipal and suburban areas of the county has resulted in increased amounts of water withdrawn from this aquifer and water-level declines in some areas. A 3-year study of the hydrogeology of the Silurian-Devonian aquifer system in Johnson County was undertaken to provide a quantitative assessment of ground water resources and to construct a ground-water flow model that can be used by local governmental agencies as a management tool.

  15. Regional Super ESPC Saves Energy and Dollars at NASA's Johnson Space Center

    International Nuclear Information System (INIS)

    Federal Energy Management Program

    2001-01-01

    This case study about energy saving performance contacts (ESPCs) presents an overview of how the NASA's Johnson Space Flight Center established an ESPC contract and the benefits derived from it. The Federal Energy Management Program instituted these special contracts to help federal agencies finance energy-saving projects at their facilities

  16. Commentary on Adele Tutter's "Design as dream and self-representation: Philip Johnson and the Glass House of Atreus".

    Science.gov (United States)

    Danze, Elizabeth A; Sonnenberg, Stephen M

    2012-06-01

    In this discussion of Adele Tutter's "Design as Dream and Self-Representation: Philip Johnson and the Glass House of Atreus" (JAPA 59/3), the architect Elizabeth Danze and the psychoanalyst Stephen Sonnenberg highlight what they see as the most important of Tutter's contributions as regards an understanding of Johnson's work. They then discuss those contributions as they illuminate the study of the relationship of architecture and design, on the one hand, and psychoanalysis on the other.

  17. Taxonomy, Ontology and Semantics at Johnson Space Center

    Science.gov (United States)

    Berndt, Sarah Ann

    2011-01-01

    At NASA Johnson Space Center (JSC), the Chief Knowledge Officer has been developing the JSC Taxonomy to capitalize on the accomplishments of yesterday while maintaining the flexibility needed for the evolving information environment of today. A clear vision and scope for the semantic system is integral to its success. The vision for the JSC Taxonomy is to connect information stovepipes to present a unified view for information and knowledge across the Center, across organizations, and across decades. Semantic search at JSC means seemless integration of disparate information sets into a single interface. Ever increasing use, interest, and organizational participation mark successful integration and provide the framework for future application.

  18. 50 CFR 80.25 - Multiyear financing under the Dingell-Johnson Sport Fish Restoration Program.

    Science.gov (United States)

    2010-10-01

    ...-Johnson Sport Fish Restoration Act in two ways: (1) States may finance the entire cost of the acquisition... Program. (a) States may finance the acquisition of lands or interests in lands including water rights and...

  19. Application of the Unbounded Probability Distribution of the Johnson System for Floods Estimation

    Directory of Open Access Journals (Sweden)

    Campos-Aranda Daniel Francisco

    2015-09-01

    Full Text Available Floods designs constitute a key to estimate the sizing of new water works and to review the hydrological security of existing ones. The most reliable method for estimating their magnitudes associated with certain return periods is to fit a probabilistic model to available records of maximum annual flows. Since such model is at first unknown, several models need to be tested in order to select the most appropriate one according to an arbitrary statistical index, commonly the standard error of fit. Several probability distributions have shown versatility and consistency of results when processing floods records and therefore, its application has been established as a norm or precept. The Johnson System has three families of distributions, one of which is the Log–Normal model with three parameters of fit, which is also the border between the bounded distributions and those with no upper limit. These families of distributions have four adjustment parameters and converge to the standard normal distribution, so that their predictions are obtained with such a model. Having contrasted the three probability distributions established by precept in 31 historical records of hydrological events, the Johnson system is applied to such data. The results of the unbounded distribution of the Johnson system (SJU are compared to the optimal results from the three distributions. It was found that the predictions of the SJU distribution are similar to those obtained with the other models in the low return periods ( 1000 years. Because of its theoretical support, the SJU model is recommended in flood estimation.

  20. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  1. Road traffic noise: self-reported noise annoyance versus GIS modelled road traffic noise exposure.

    Science.gov (United States)

    Birk, Matthias; Ivina, Olga; von Klot, Stephanie; Babisch, Wolfgang; Heinrich, Joachim

    2011-11-01

    self-reported road traffic noise annoyance is commonly used in epidemiological studies for assessment of potential health effects. Alternatively, some studies have used geographic information system (GIS) modelled exposure to road traffic noise as an objective parameter. The aim of this study was to analyse the association between noise exposure due to neighbouring road traffic and the noise annoyance of adults, taking other determinants into consideration. parents of 951 Munich children from the two German birth cohorts GINIplus and LISAplus reported their annoyance due to road traffic noise at home. GIS modelled road traffic noise exposure (L(den), maximum within a 50 m buffer) from the noise map of the city of Munich was available for all families. GIS-based calculated distance to the closest major road (≥10,000 vehicles per day) and questionnaire based-information about family income, parental education and the type of the street of residence were explored for their potential influence. An ordered logit regression model was applied. The noise levels (L(den)) and the reported noise annoyance were compared with an established exposure-response function. the correlation between noise annoyance and noise exposure (L(den)) was fair (Spearman correlation r(s) = 0.37). The distance to a major road and the type of street were strong predictors for the noise annoyance. The annoyance modelled by the established exposure-response function and that estimated by the ordered logit model were moderately associated (Pearson's correlation r(p) = 0.50). road traffic noise annoyance was associated with GIS modelled neighbouring road traffic noise exposure (L(den)). The distance to a major road and the type of street were additional explanatory factors of the noise annoyance appraisal.

  2. Magnetic Thermometer: Thermal effect on the Agglomeration of Magnetic Nanoparticles by Magnetic field

    Science.gov (United States)

    Jin, Daeseong; Kim, Hackjin

    2018-03-01

    We have investigated the agglomeration of magnetite nanoparticles in the aqueous solution under magnetic field by measuring temporal change of magnetic weight. The magnetic weight corresponds to the force due to the magnetization of magnetic materials. Superparamagnetic magnetite nanoparticles are synthesized and used in this work. When the aqueous solution of magnetite nanoparticle is placed under magnetic field, the magnetic weight of the sample jumps instantaneously by Neel and Brown mechanisms and thereafter increases steadily following a stretched exponential function as the nanoparticles agglomerate, which results from the distribution of energy barriers involved in the dynamics. Thermal motions of nanoparticles in the agglomerate perturb the ordered structure of the agglomerate to reduce the magnetic weight. Fluctuation of the structural order of the agglomerate by temperature change is much faster than the formation of agglomerate and explained well with the Boltzmann distribution, which suggests that the magnetic weight of the agglomerate works as a magnetic thermometer.

  3. Paradise and Politics in the Music of Blind Willie Johnson

    Directory of Open Access Journals (Sweden)

    Owen Coggins

    2012-05-01

    Full Text Available I investigate the politics of paradises in the 1920s African-American gospel blues of Blind Willie Johnson. His recordings are apocalyptic vignettes which juxtapose and conflate paradises, using many different voices. I describe the theological and political paradises in Johnson’s songs: the Old Testament journey to Canaan; the post-death heaven in the New Testament; Christ’s kingdom on earth in Revelation; freedom in Northern cities or Canada; and a utopian dream of political emancipation of African-Americans and transformation of society in the South. I outline the various voices present in Johnson’s recordings: vocal styles; accompanying singers; the guitar; grammatical, textual and lexical voices; and the silent voices of technology and time. I suggest traces of a subtle political activism in these voices and paradises, and explore uses of these voices in linking paradises, arguing that the complex transitions enhance the force of signification and frustrate attempts to finalise meanings. Many interpretations of Johnson’s recordings, however, seek to determine final meaning, and I discuss the limitations of such attempts, limitations which not only underestimate the richness of the recordings but deny Johnson any political awareness or agency. In cautioning against this kind of project, I call for a hearing open to plural interpretations, and suggest political potential not only in coded messages, but in radical indeterminacy itself.

  4. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  5. Measurement of temperature distributions in large pool fires with the use of directional flame thermometers

    International Nuclear Information System (INIS)

    Koski, Jorman A.

    2000-01-01

    Temperatures inside the flame zone of large regulatory pool fires measured during tests of radioactive materials packages vary widely with both time and position. Measurements made with several Directional Flame Thermometers, in which a thermocouple is attached to a thin metal sheet that quickly approaches flame temperatures, have been used to construct fire temperature distributions and cumulative probability distributions. As an aid to computer simulations of these large fires, these distributions are presented. The distributions are constructed by sorting fire temperature data into bins 10 C wide. A typical fire temperature distribution curve has a gradual increase starting at about 600 C, with the number of observations increasing to a peak near 1000 C, followed by an abrupt decrease in frequency, with no temperatures observed above 1200 C

  6. Stevens-Johnson syndrome following use of metronidazole in a dental patient.

    Science.gov (United States)

    Mazumdar, Goutameswar; Shome, Koushik

    2014-01-01

    Metronidazole alone rarely causes Stevens-Johnson syndrome (SJS). We present a case of an elderly male patient who, following metronidazole use, developed neurological symptoms followed by pain and blisters on both soles, erythema of face and neck, scrotal itching and erosion, and hemorrhagic encrustation around the lips and oral mucous membrane. Initial neurological symptoms followed by mucocutaneous manifestation of SJS following metronidazole use is probably a new presentation of this case.

  7. Evaluation of the Johnson AG-1007-7 (G-7) microwave motion detection system

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    A series of tests was performed on the Johnson Model AG-1007-7 motion detection system. The primary objectives of these tests were to determine sensor detection patterns and to quantitate the effects of intruder velocity. System susceptibility to fluorescent lights, oscillatory motion, and environmental factors was also examined.

  8. Evaluation of the Johnson AG-1007-7 (G-7) microwave motion detection system

    International Nuclear Information System (INIS)

    1979-01-01

    A series of tests was performed on the Johnson Model AG-1007-7 motion detection system. The primary objectives of these tests were to determine sensor detection patterns and to quantitate the effects of intruder velocity. System susceptibility to fluorescent lights, oscillatory motion, and environmental factors was also examined

  9. Investigation of Monnose-Binding Lectin gene Polymorphism in Patients with Erythema Multiforme, Stevens-Johnson Syndrome and Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Overlap Syndrome

    Directory of Open Access Journals (Sweden)

    Sevil Toka

    2012-09-01

    Full Text Available Objective: Monnose-Binding lectin (MBL appears to play an important role in the immune system. The genetic polymorphisms in the MBL2 gene can result in a reduction of serum levels, leading to a predisposition to recurrent infection. The aim of this study is to investigate the influence of a polymorphism in codon 54 of the MBL2 gene on the susceptibility to Erythema Multiforme, Stevens-Johnson Syndrome and Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Overlap Syndrome (EM, SJS and SJS/TEN overlap syndrome. Material and Methods: Our study included 64 patients who were clinically and/or histopathologically diagnosed with EM, SJS, and SJS/TEN overlap syndrome and 66 healthy control subjects who were genotyped for the MBL2 gene codon 54 polymorphism using the PCR-RFLP method. For all statistical analyses, the level of significance was set at p<0.05. Results: The prevalence of the B allele was 18% in the EM, SJS and SJS/TEN patient groups and 13% in the control group. No significant differences in allele frequencies of any polymorphism were observed between the patient and control groups, although the B allele was more frequent in the patient groups (p=0.328.Conclusion: Our results provide no evidence of a relationship between MBL2 gene codon 54 polymorphism and the susceptibility to EM, SJS and SJS/TEN overlap syndrome. However, these findings should be confirmed in studies with a larger sample size.

  10. Misidentifying the Effects of Parental Incarceration? A Comment on Johnson and Easterling (2012)

    Science.gov (United States)

    Wildeman, Christopher; Wakefield, Sara; Turney, Kristin

    2013-01-01

    In a recent "Journal of Marriage and Family" article, Johnson and Easterling (2012) reviewed research on the effects of parental incarceration on child well-being, focusing on the various conceptual frameworks linking parental incarceration and child well-being and the "important methodological and conceptual challenges related to selection bias"…

  11. Guidelines for the management of Stevens-Johnson syndrome/toxic epidermal necrolysis: An Indian perspective.

    Science.gov (United States)

    Gupta, Lalit Kumar; Martin, Abhay Mani; Agarwal, Nidheesh; D'Souza, Paschal; Das, Sudip; Kumar, Rajesh; Pande, Sushil; Das, Nilay Kanti; Kumaresan, Muthuvel; Kumar, Piyush; Garg, Anubhav; Singh, Saurabh

    2016-01-01

    Stevens-Johnson syndrome and toxic epidermal necrolysis are severe, life-threatening mucocutaneous adverse drug reactions with a high morbidity and mortality that require immediate medical care. The various immunomodulatory treatments include systemic corticosteroids, cyclosporine, intravenous immunoglobulin, cyclophosphamide, plasmapheresis and tumor necrosis factor-α inhibitors. The ideal therapy of Stevens-Johnson syndrome/toxic epidermal necrolysis still remains a matter of debate as there are only a limited number of studies of good quality comparing the usefulness of different specific treatments. The aim of this article is to comprehensively review the published medical literature and frame management guidelines suitable in the Indian perspective. The Indian Association of Dermatologists, Venereologists and Leprologists (IADVL) assigned the task of preparing these guidelines to its special interest group on cutaneous adverse drug reactions. The group performed a comprehensive English language literature search for management options in Stevens-Johnson syndrome/toxic epidermal necrolysis across multiple databases (PubMed, EMBASE, MEDLINE and Cochrane) for keywords (alone and in combination) and MeSH items such as "guidelines," "Stevens-Johnson syndrome," "toxic epidermal necrolysis," "corticosteroids," "intravenous immunoglobulin," "cyclosporine" and "management." The available evidence was evaluated using the strength of recommendation taxonomy and graded using a three-point scale. A draft of clinical recommendations was developed on the best available evidence which was also scrutinized and critically evaluated by the IADVL Academy of Dermatology. Based on the inputs received, this final consensus statement was prepared. A total of 104 articles (meta-analyses, prospective and retrospective studies, reviews [including chapters in books], previous guidelines [including Indian guidelines of 2006] and case series) were critically evaluated and the evidence

  12. 78 FR 29367 - Access to Confidential Business Information by ABT Associates, Incorporated; Perry Johnson...

    Science.gov (United States)

    2013-05-20

    ... contractor ABT Associates, Incorporated (ABT) and six (6) auditing organizations: Perry Johnson Registrars...), Resource Conservation and Sustainability Division (RCSD) as it conducts a study of the implementation of... industry to contain auditing tools, ownership/operation agreements, amounts and types of e-waste processed...

  13. An evaluation of the Johnson-Cook model to simulate puncture of 7075 aluminum plates.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo; Orient, George Edgar

    2014-02-01

    The objective of this project was to evaluate the use of the Johnson-Cook strength and failure models in an adiabatic finite element model to simulate the puncture of 7075- T651 aluminum plates that were studied as part of an ASC L2 milestone by Corona et al (2012). The Johnson-Cook model parameters were determined from material test data. The results show a marked improvement, in particular in the calculated threshold velocity between no puncture and puncture, over those obtained in 2012. The threshold velocity calculated using a baseline model is just 4% higher than the mean value determined from experiment, in contrast to 60% in the 2012 predictions. Sensitivity studies showed that the threshold velocity predictions were improved by calibrating the relations between the equivalent plastic strain at failure and stress triaxiality, strain rate and temperature, as well as by the inclusion of adiabatic heating.

  14. Mida andis teile Tallinna ülikooli suvekoolis osalemine? / Ipios Nikos, Cheryl Johnson, Jevgenijs Kaktinš...[jt.

    Index Scriptorium Estoniae

    2010-01-01

    Küsimusele vastasid arst Ipios Nikos, luteri-anglikaani vaimulik, arheoloog Cheryl Johnson, ökonomist Jevgenijs Kaktinš, filosoofia magistrant Gabriele Avincola ja filosoofia üliõpilane Kaia Otstak

  15. Sensors, Volume 4, Thermal Sensors

    Science.gov (United States)

    Scholz, Jorg; Ricolfi, Teresio

    1996-12-01

    'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume describes the construction and applicational aspects of thermal sensors while presenting a rigorous treatment of the underlying physical principles. It provides a unique overview of the various categories of sensors as well as of specific groups, e.g. temperature sensors (resistance thermometers, thermocouples, and radiation thermometers), noise and acoustic thermometers, heat-flow and mass-flow sensors. Specific facettes of applications are presented by specialists from different fields including process control, automotive technology and cryogenics. This volume is an indispensable reference work and text book for both specialists and newcomers, researchers and developers.

  16. Direct-reading dial for noise temperature and noise resistance

    DEFF Research Database (Denmark)

    Diamond, J.M.

    1967-01-01

    An attenuator arrangement for a noise generator is described. The scheme permits direct reading of both noise resistance and noise temperature¿the latter with a choice of source resistance.......An attenuator arrangement for a noise generator is described. The scheme permits direct reading of both noise resistance and noise temperature¿the latter with a choice of source resistance....

  17. Noise frame duration, masking potency and whiteness of temporal noise.

    Science.gov (United States)

    Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti

    2002-09-01

    Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.

  18. Robotic Technology Efforts at the NASA/Johnson Space Center

    Science.gov (United States)

    Diftler, Ron

    2017-01-01

    The NASA/Johnson Space Center has been developing robotic systems in support of space exploration for more than two decades. The goal of the Center’s Robotic Systems Technology Branch is to design and build hardware and software to assist astronauts in performing their mission. These systems include: rovers, humanoid robots, inspection devices and wearable robotics. Inspection systems provide external views of space vehicles to search for surface damage and also maneuver inside restricted areas to verify proper connections. New concepts in human and robotic rovers offer solutions for navigating difficult terrain expected in future planetary missions. An important objective for humanoid robots is to relieve the crew of “dull, dirty or dangerous” tasks allowing them more time to perform their important science and exploration missions. Wearable robotics one of the Center’s newest development areas can provide crew with low mass exercise capability and also augment an astronaut’s strength while wearing a space suit.This presentation will describe the robotic technology and prototypes developed at the Johnson Space Center that are the basis for future flight systems. An overview of inspection robots will show their operation on the ground and in-orbit. Rovers with independent wheel modules, crab steering, and active suspension are able to climb over large obstacles, and nimbly maneuver around others. Humanoid robots, including the First Humanoid Robot in Space: Robonaut 2, demonstrate capabilities that will lead to robotic caretakers for human habitats in space, and on Mars. The Center’s Wearable Robotics Lab supports work in assistive and sensing devices, including exoskeletons, force measuring shoes, and grasp assist gloves.

  19. Autoimmune Progesterone Dermatitis Presenting as Stevens-Johnson Syndrome.

    Science.gov (United States)

    Drayer, Sara M; Laufer, Larry R; Farrell, Maureen E

    2017-10-01

    Autoimmune progesterone dermatitis is an uncommon disease presenting with cyclical skin eruptions corresponding with the menstrual cycle luteal phase. Because symptoms are precipitated by rising progesterone levels, treatment relies on hormone suppression. A 22-year-old nulligravid woman presented with symptoms mistaken for Stevens-Johnson syndrome. A cyclic recurrence of her symptoms was noted, and the diagnosis of autoimmune progesterone dermatitis was made by an intradermal progesterone challenge. After 48 months, she remained refractory to medical management and definitive surgical treatment with bilateral oophorectomy was performed. Autoimmune progesterone dermatitis is a challenging diagnosis owing to its rarity and variety of clinical presentations. Treatment centers on suppression of endogenous progesterone and avoidance of exogenous triggers. When these modalities fail, surgical management must be undertaken.

  20. Endoscopic cyclophotocoagulation in refractory glaucoma after osteo-odonto-keratoprosthesis in Stevens-Johnson syndrome: a case report.

    Science.gov (United States)

    Forlini, Matteo; Adabache-Guel, Tania; Bratu, Adriana; Rossini, Paolo; Mingaine, Mpekethu Sam; Cavallini, Gian Maria; Forlini, Cesare

    2014-01-01

    To report successful treatment of refractive glaucoma in a patient submitted to osteo-odonto-keratoprosthesis surgery for Stevens-Johnson syndrome. An interventional case report. The patient is a 62-year-old Indian man with known Stevens-Johnson syndrome since 1972 secondary to tetracycline therapy, with bilateral dry eye and corneal blindness. He underwent symblepharon release surgery with mucous membrane graft in both eyes. Osteo-odonto-keratoprosthesis surgery was later performed on the left eye. He was submitted to 2 Ahmed valve implants to control secondary glaucoma but visual fields continued to worsen; hence, he underwent endoscopic 140° cyclophotocoagulation with a good control of IOP. Endoscopic cyclophotocoagulation as alternative treatment provides good results in refractory glaucoma after osteo-odonto-keratoprosthesis surgery.

  1. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  2. Feasibility Study of Economics and Performance of Solar Photovoltaics at Johnson County Landfill

    Energy Technology Data Exchange (ETDEWEB)

    Salasovich, J.; Mosey, G.

    2012-01-01

    The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Johnson County Landfill in Shawnee, Kansas, for a feasibility study of renewable energy production. Citizens of Shawnee, city planners, and site managers are interested in redevelopment uses for landfills in Kansas that are particularly well suited for grid-tied solar photovoltaic (PV) installation. This report assesses the Johnson County Landfill for possible grid-tied PV installations and estimates the cost, performance, and site impacts of three different PV options: crystalline silicon (fixed tilt), crystalline silicon (single-axis tracking), and thin film (fixed tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. The report findings are applicable to other landfills in the surrounding area.

  3. Stevens Johnson Syndrome in a patient undergoing gynaecological brachytherapy: An association or an incident?

    International Nuclear Information System (INIS)

    Ferreira, M. R.; Amado, A.; Jorge, M.; Grillo, I. M.

    2011-01-01

    Background: Stevens Johnson Syndrome and Erythema Multiforme are hypersensitivity skin reactions generally arising in the context of multiple causes. Radiation therapy is considered to be one of these causes, although most reports are hindered by concomitant medications. Aim: The aim of this paper was to present a case of Stevens Johnson Syndrome arising in a patient undergoing gynaecological brachytherapy with an unusual presentation. Case:We describe a case of a 56-year-old woman with endometrial cancer undergoing adjuvant gynaecological radiotherapy. While undergoing a gynaecological brachytherapy boost, she developed bilateral conjunctivitis that progressed to oral mucositis and pruritic erythema with sloughing of the skin on her arms and legs but not the torso or irradiated fields (namely the vaginal mucosa). Conclusion: This case illustrates the association of RT/SJS; however, it also raises the question of patients undergoing RT being more susceptible to SJS as opposed to a direct cause of the disease. (authors)

  4. Development of a platinum resistance thermometer on the silicon substrate for phase change studies

    International Nuclear Information System (INIS)

    Cai, Qingjun; Chen, Ya-Chi; Tsai, Chialun; DeNatale, Jeffrey F

    2012-01-01

    Resistance temperature detectors are commonly used measurement sensors in heat transfer studies. In many resistance temperature detectors, the platinum resistance thermometer (PRT) is chemically stable, has a wide temperature measurement range and possesses high measurement accuracy. In phase change studies of carbon nanotubes, bi-porous structures for microelectronic thermal management, 100 nm thick PRTs are developed on silicon substrates with 10 nm titanium adhesive to achieve precise and interface-free temperature measurements. After an annealing at 375 °C, the PRT samples are calibrated at a temperature range from 20 to 180 °C. Measurement hysteresis of temperature appears in thermal cycles. Electrical resistance tends to become low during all heating periods, which establishes the maximum measurement deviation of 10 °C. Experimental results from two different thin-film PRTs indicate that accurate and repeatable temperature measurements can be achieved by either reducing heating speed or using data in the cooling period. (paper)

  5. Sounds and Noises. A Position Paper on Noise Pollution.

    Science.gov (United States)

    Chapman, Thomas L.

    This position paper focuses on noise pollution and the problems and solutions associated with this form of pollution. The paper is divided into the following five sections: Noise and the Ear, Noise Measurement, III Effects of Noise, Acoustics and Action, and Programs and Activities. The first section identifies noise and sound, the beginnings of…

  6. Tegafur/gimeracil/oteracil (TS-1 induced Stevens–Johnson syndrome: Case report

    Directory of Open Access Journals (Sweden)

    Satoko Minakawa

    2013-09-01

    Full Text Available TS-1 is an oral fluoropyrimidine anticancer drug that contains tegafur, gimeracil, and oteracil. A 78-year-old Japanese male who was diagnosed with carcinoma of the oral floor (rT4aN0M0 was prescribed a standard dose of TS-1 (80 mg/day. On Day 8 after administration of TS-1, an eruption developed. There was erythema, along with vesicles and erosions involving the lip, face, neck, trunk, limbs, and genitals. The drug-induced lymphocyte stimulation test (DLST for TS-1 was negative on the 23rd day, but positive on the 43rd day (20 days after discontinuing prednisolone. The condition was diagnosed as Stevens–Johnson syndrome due to TS-1 because of the clinical course and laboratory results. This case and 24 cases previously reported in the literature were analyzed. The types of drug eruption were drug-related lupus (9 cases, acral erythema (7 cases, scleroderma-like skin lesion (2 cases, Stevens–Johnson syndrome (2 cases, lichenoid eruption (1 case, purpura (1 case, lichen planus (1 case, erythema multiforme (1 case, hypopigmentation (1 case and toxic epidermal necrolysis (1 case, respectively. In view of the increasing usage of TS-1 in several common cancers, clinicians should be aware of drug eruptions due to TS-1.

  7. Peristaltic transport of Johnson-Segalman fluid under effect of a magnetic field

    Directory of Open Access Journals (Sweden)

    Moustafa Elshahed

    2005-01-01

    Full Text Available The peristaltic transport of Johnson-Segalman fluid by means of an infinite train of sinusoidal waves traveling along the walls of a two-dimensional flexible channel is investigated. The fluid is electrically conducted by a transverse magnetic field. A perturbation solution is obtained for the case in which amplitude ratio is small. Numerical results are reported for various values of the physical parameters of interest.

  8. Fire Hydrants, Both public and private fire hydrants in Johnson County. Spring Hill is hte only entity missing. Data is limited to CUE (Collaborative Utiity Exchange) Participants and subcontractors of them., Published in 2004, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Fire Hydrants dataset current as of 2004. Both public and private fire hydrants in Johnson County. Spring Hill is hte only entity missing. Data is limited to CUE...

  9. Noise-induced hearing loss: a recreational noise perspective.

    Science.gov (United States)

    Ivory, Robert; Kane, Rebecca; Diaz, Rodney C

    2014-10-01

    This review will discuss the real-world risk factors involved in noise-induced hearing loss as a result of common and popular recreational activities prone to mid and high levels of noise exposure. Although there are currently no interventional measures available to reverse or mitigate preexisting hearing loss from noise, we discuss the vital importance of hearing loss prevention from noise exposure avoidance and reduction. Despite a seeming understanding of the effects of noise exposure from various recreational activities and devices, a large percentage of the general public who is at risk of such noise-induced hearing loss still chooses to refrain from using hearing protection instruments. While occupational exposures pose the greatest traditional risk to hearing conservation in selected workers, recreational risk factors for noise-induced hearing loss may be more insidious in overall effect given the indifferent attitude of much of the general public and particularly our youths toward hearing protection during recreational activities. Active counseling regarding the consequences of excessive noise exposure and the potential benefits to hearing from usage of hearing protection instruments is critical to providing best possible care in the hearing health professions.

  10. Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer

    International Nuclear Information System (INIS)

    Becerro, E.; Carreira, M.

    1968-01-01

    The solubility problems raised by some components of the polymeric residue of irradiated polyphenolic coolants, which make it necessary to operate with very small samples, have been solved by means of a differential cryoscopic technique using a thermoelectric thermometer (thermal) as sensitive element. The method is based on the direct measurement of the difference between the freezing points of the investigated solution and of a reference solution whose concentration may be changed at will. The change of Δ V (mV) versus c(molal) is linear, the equivalent point being determined either analytically or graphically depending on the required accuracy. The method has been tested by measurements on pure polyphenyls, using diphenyl ether as solvent. It has been also applied to the main prospective coolants for the DON reactor. Working with 10 2 molal solutions the accuracy is better than ± 2 per cent. (Author) 2 refs

  11. Stevens-Johnson syndrome progressing to toxic epidermal necrolysis with haloperidol and carbamazepine combination

    Directory of Open Access Journals (Sweden)

    Ajay Kumar

    2011-01-01

    Full Text Available Carbamazepine and other anticonvulsants are commoner cause of severe adverse cutaneous drug reactions such as erythema multiforme, toxic epidermal necrolysis (TEN, and Stevens-Johnson syndrome (SJS. We report a case of SJS rapidly progressing to TEN with a combination of haloperidol and carbamazepine in a patient with bipolar affective disorder. The pathophysiological mechanism underlying this reaction is discussed.

  12. Practical ranges of loudness levels of various types of environmental noise, including traffic noise, aircraft noise, and industrial noise

    NARCIS (Netherlands)

    Salomons, E.M.; Janssen, S.A.

    2011-01-01

    In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a

  13. Response to Johnson: A random sample versus the radical event

    Directory of Open Access Journals (Sweden)

    Elie Ayache

    2016-12-01

    Full Text Available Timothy Johnson’s working hypothesis in his review of my latest book, The Medium of Contingency, is that I (as well as the ‘quants’ involved in the derivative pricing industry do not understand the foundations of abstract probability theory. In this response, I show that this is not the case. On the contrary, rules and protocols which are common in the derivative pricing industry, the result of which can be an extension of abstract probability theory as it now stands, seem to elude Johnson. To address these failings, I provide theoretical reflections on probability theory and its formalisms.

  14. Transnational Impulses as Simulation in Colin Johnson's (Mudrooroo's Fiction.

    Directory of Open Access Journals (Sweden)

    Clare Archer-Lean

    2013-05-01

    Full Text Available Works of Australian Literature have frequently been situated within national literary frameworks. But there is much recent scholarship that contests such ideas and explores transnational engagement in literary production. An author that has been seen as embodying the spectral nature of the Australian literary paradigm is Colin Johnson, pseudonym Mudrooroo. While, the complexities around Mudrooroo's identity as black Australian author are infamous: these biographical complexities are not the focus of this paper. Instead, Mudrooroo's Master of the Ghost Dreaming Series is explored as an evocation of place that encompasses a series of ever widening spheres: the local, the regional, the national, the transnational, the trans-human and the cosmic.

  15. Effects of a traffic noise background on judgements of aircraft noise

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1974-01-01

    A study was conducted in which subjects judged aircraft noises in the presence of road traffic background noise. Two different techniques for presenting the background noises were evaluated. For one technique, the background noise was continuous over the whole of a test session. For the other, the background noise was changed with each aircraft noise. A range of aircraft noise levels and traffic noise levels were presented to simulate typical indoor levels.

  16. The Federal Role in Adolescent Literacy from Johnson through Obama: A Policy Regimes Analysis

    Science.gov (United States)

    Hauptli, Meghan V.; Cohen-Vogel, Lora

    2013-01-01

    This article examines the federal role in adolescent literacy from its roots in Lyndon B. Johnson's administration with the Economic Opportunity Act (1964) through the Reading for Understanding grants of 2010. The authors consider the extent to which the recent attention to and changes in the federal approach to adolescent literacy can be…

  17. Evaluation of noise pollution in oil extracting region of Lavan and the effect of noise enclosure on noise abatement

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2007-09-01

    Full Text Available Background and aims   Overexposure to industrial noise pollution induce hearing loss workers. Occupational hearing loss may cause interference whit oral communication, so it may  increase the risk of occupational accidents in workplace as well as affects whit social activities.  This study was conducted on Lavan Island, are of oil extracting regions in the south of Iran. The  object of this study was to evaluate noise pollution and determining the effect of noise enclosure  on noise abatement.   Methods   The noise sources were recognized and noise pressure level was measured by CEL- 440. Noise dose of the exposed workers in high level noise area were measured by CEL 272.   Results   Major noise sources were gas turbines, diesel generators, compressors, fans and gas containing pips, noise contour map revealers that noise level were higher than the recommended national exposure limit. The results of workers noise dose show that their noise exposure were  higher than the recommended value, (p<0.001. Finally, by using the results of noise frequency  analysis of different noise sources, the noise pressure level of each sources was determined in   terms of enclosing them.   Conclusion   By enclosing the noise sources, noise pressure levels can be lowered douse to  acceptable levels but limitation of applying enclosure should be regarded.  

  18. Noise cancellation properties of displacement noise free interferometer

    International Nuclear Information System (INIS)

    Sato, Shuichi; Kawamura, Seiji; Nishizawa, Atsushi; Chen Yanbei

    2010-01-01

    We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.

  19. Masking potency and whiteness of noise at various noise check sizes.

    Science.gov (United States)

    Kukkonen, H; Rovamo, J; Näsänen, R

    1995-02-01

    The masking effect of spatial noise can be increased by increasing either the rms contrast or check size of noise. In this study, the authors investigated the largest noise check size that still mimics the effect of white noise in grating detection and how it depends on the bandwidth and spatial frequency of a grating. The authors measured contrast energy thresholds, E, for vertical cosine gratings at various spatial frequencies and bandwidths. Gratings were embedded in two-dimensional spatial noise. The side length of the square noise checks was varied in the experiments. The spectral density, N(0,0), of white spatial noise at zero frequency was calculated by multiplying the noise check area by the rms contrast of noise squared. The physical signal-to-noise ratio at threshold [E/N(0,0)]0.5 was initially constant but then started to decrease. The largest noise check that still produced a constant physical signal-to-noise ratio at threshold was directly proportional to the spatial frequency. When expressed as a fraction of grating cycle, the largest noise check size depended only on stimulus bandwidth. The smallest number of noise checks per grating cycle needed to mimic the effect of white noise decreased from 4.2 to 2.6 when the number of grating cycles increased from 1 to 64. Spatial noise can be regarded as white in grating detection if there are at least four square noise checks per grating cycle at all spatial frequencies.

  20. Non-Markovian noise

    International Nuclear Information System (INIS)

    Fulinski, A.

    1994-01-01

    The properties of non-Markovian noises with exponentially correlated memory are discussed. Considered are dichotomic noise, white shot noise, Gaussian white noise, and Gaussian colored noise. The stationary correlation functions of the non-Markovian versions of these noises are given by linear combinations of two or three exponential functions (colored noises) or of the δ function and exponential function (white noises). The non-Markovian white noises are well defined only when the kernel of the non-Markovian master equation contains a nonzero admixture of a Markovian term. Approximate equations governing the probability densities for processes driven by such non-Markovian noises are derived, including non-Markovian versions of the Fokker-Planck equation and the telegrapher's equation. As an example, it is shown how the non-Markovian nature changes the behavior of the driven linear process

  1. Noise-induced annoyance from transportation noise: short-term responses to a single noise source in a laboratory.

    Science.gov (United States)

    Kim, Jaehwan; Lim, Changwoo; Hong, Jiyoung; Lee, Soogab

    2010-02-01

    An experimental study was performed to compare the annoyances from civil-aircraft noise, military-aircraft noise, railway noise, and road-traffic noise. Two-way within-subjects designs were applied in this research. Fifty-two subjects, who were naive listeners, were given various stimuli with varying levels through a headphone in an anechoic chamber. Regardless of the frequency weighting network, even under the same average energy level, civil-aircraft noise was the most annoying, followed by military-aircraft noise, railway noise, and road-traffic noise. In particular, penalties in the time-averaged, A-weighted sound level (TAL) of about 8, 5, and 5 dB, respectively, were found in the civil-aircraft, military-aircraft, and railway noises. The reason could be clarified through the high-frequency component and the variability in the level. When people were exposed to sounds with the same maximum A-weighted level, a railway bonus of about 3 dB was found. However, transportation noise has been evaluated by the time-averaged A-weighted level in most countries. Therefore, in the present situation, the railway bonus is not acceptable for railway vehicles with diesel-electric engines.

  2. Entry layout in the history of English lexicography: Bailey 1736, Martin 1749 and Johnson 1755

    Directory of Open Access Journals (Sweden)

    Ruxandra Vişan

    2010-01-01

    Full Text Available The present paper focuses on the history of lexicography and proposes a comparative analysis of three significant English dictionaries of the 18th century: Nathan Bailey’s Dictionarium Britannicum (second edition, 1736, Benjamin Martin’s Lingua Britannica Reformata (first edition, 1749, Samuel Johnson’s Dictionary of the English Language (first edition, 1755. The paper discusses the structure of the entries in these texts, concentrating on the changes undergone from Bailey to Johnson, and attempts to show that the increased complexity of Martin’s and Johnson’s lexicographic entries marks a departure from the model of the “universal” dictionary. While the structure of universal dictionaries such as Bailey’s retains important similarities with that of the encyclopaedias of the time, later 18th century dictionaries, such as those of Johnson, are closer in structure to contemporary dictionaries of the English language, indicating a more complete separation of what starts to count as “linguistic” from what starts to count as “encyclopaedic”.

  3. Environmental noise and noise modelling-some aspects in Malaysian development

    International Nuclear Information System (INIS)

    Leong, Mohd Salman; Mohd Shafiek bin Hj Yaacob

    1994-01-01

    Environmental noise is of growing concern in Malaysia with the increasing awareness of the need for an environmental quality consistent with improved quality of life. While noise is one of the several elements in an Environmental Impact Assessment report, the degree of emphasis in the assessment is not as thorough as other aspects in the EIA study. The measurements, prediction (if at all any), and evaluation tended to be superficial. The paper presents a summary of correct noise descriptors and annoyance assessment parameters appropriate for the evaluation of environmental noise. The paper further highlights current inadequacies in the Environmental Quality Act for noise pollution, and annoyance assessment. Some examples of local noise pollution are presented. A discussion on environmental noise modelling is presented. Examples illustrating environmental noise modelling for a mining operation and a power station are given. It is the authors' recommendation that environmental noise modelling be made mandatory in all EIA studies such that a more definitive assessment could be realised

  4. Annoyance of low frequency noise and traffic noise

    DEFF Research Database (Denmark)

    Mortensen, F.R.; Poulsen, Torben

    2001-01-01

    The annoyance of different low frequency noise sources was determined and compared to the annoyance from traffic noise. Twenty-two subjects participated in laboratory listening tests. The sounds were presented by loudspeakers in a listening room and the spectra of the low frequency noises were...

  5. Evaluating noise abatement measures using strategic noise maps

    NARCIS (Netherlands)

    Borst, H.C.; Miedema, H.M.E.; Laan, W.P.N. van der; Lohman, W.J.A.

    2006-01-01

    Noise annoyance due to transportation is widespread in industrialized countries and in urban areas in the developing countries. The European Noise Directive (END) requires an assessment of the noise situation as well as the formulation of action plans for the reduction of the number of people

  6. Renewable Energy at NASA's Johnson Space Center

    Science.gov (United States)

    McDowall, Lindsay

    2014-01-01

    NASA's Johnson Space Center has implemented a great number of renewable energy systems. Renewable energy systems are necessary to research and implement if we humans are expected to continue to grow and thrive on this planet. These systems generate energy using renewable sources - water, wind, sun - things that we will not run out of. Johnson Space Center is helping to pave the way by installing and studying various renewable energy systems. The objective of this report will be to examine the completed renewable energy projects at NASA's Johnson Space Center for a time span of ten years, beginning in 2003 and ending in early 2014. This report will analyze the success of each project based on actual vs. projected savings and actual vs. projected efficiency. Additionally, both positive and negative experiences are documented so that lessons may be learned from past experiences. NASA is incorporating renewable energy wherever it can, including into buildings. According to the 2012 JSC Annual Sustainability Report, there are 321,660 square feet of green building space on JSC's campus. The two projects discussed here are major contributors to that statistic. These buildings were designed to meet various Leadership in Energy and Environmental Design (LEED) Certification criteria. LEED Certified buildings use 30 to 50 percent less energy and water compared to non-LEED buildings. The objectives of this project were to examine data from the renewable energy systems in two of the green buildings onsite - Building 12 and Building 20. In Building 12, data was examined from the solar photovoltaic arrays. In Building 20, data was examined from the solar water heater system. By examining the data from the two buildings, it could be determined if the renewable energy systems are operating efficiently. Objectives In Building 12, the data from the solar photovoltaic arrays shows that the system is continuously collecting energy from the sun, as shown by the graph below. Building 12

  7. Fighting with Reality: Considering Mark Johnson's Pragmatic Realism through Bruce Lee's Jeet Kune Do Method

    Science.gov (United States)

    Miller, Alexander David

    2015-01-01

    This dissertation considers the supportive and complementary relation between Mark Johnson's embodied realism and Bruce Lee's Jeet Kune Do as a philosophical practice. In exploring this relationship, the emphasis on one's embodiment condition and its relationship with metaphor and self-expression are the primary focus. First, this work involves…

  8. Noise annoys: effects of noise on breeding great tits depend on personality but not on noise characteristics

    NARCIS (Netherlands)

    Naguib, M.; Van Oers, K.; Braakhuis, A.; Griffioen, M.; De Goede, P.; Waas, J.R.

    2013-01-01

    Anthropogenic noise can have serious implications for animals, especially when they communicate acoustically. Yet, the impacts of noise may depend not only on noise characteristics but also on an individual's coping style or personality. We tested whether noise is more disturbing if it masks

  9. Revisiting Johnson and Jackson boundary conditions for granular flows

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tingwen; Benyahia, Sofiane

    2012-07-01

    In this article, we revisit Johnson and Jackson boundary conditions for granular flows. The oblique collision between a particle and a flat wall is analyzed by adopting the classic rigid-body theory and a more realistic semianalytical model. Based on the kinetic granular theory, the input parameter for the partial-slip boundary conditions, specularity coefficient, which is not measurable in experiments, is then interpreted as a function of the particle-wall restitution coefficient, the frictional coefficient, and the normalized slip velocity at the wall. An analytical expression for the specularity coefficient is suggested for a flat, frictional surface with a low frictional coefficient. The procedure for determining the specularity coefficient for a more general problem is outlined, and a working approximation is provided.

  10. Factors Affecting Student Loan Default Rate at Johnson County Community College: A Multivariate Analysis of Student Loan Default and Repayment between Years 2006 and 2008

    Science.gov (United States)

    Butler, Cassandra

    2012-01-01

    This study utilized a quantitative design using archival data from Johnson County Community College (JCCC), located in Johnson County, Kansas, and the Office of Financial Aid for students who graduated, withdrew or dropped out of the college in academic years 2006, 2007 and 2008. Because this study used archival data, we can only show…

  11. The effects of noise reduction technologies on the acceptance of background noise.

    Science.gov (United States)

    Lowery, Kristy Jones; Plyler, Patrick N

    2013-09-01

    Directional microphones (D-Mics) and digital noise reduction (DNR) algorithms are used in hearing aids to reduce the negative effects of background noise on performance. Directional microphones attenuate sounds arriving from anywhere other than the front of the listener while DNR attenuates sounds with physical characteristics of noise. Although both noise reduction technologies are currently available in hearing aids, it is unclear if the use of these technologies in isolation or together affects acceptance of noise and/or preference for the end user when used in various types of background noise. The purpose of the research was to determine the effects of D-Mic, DNR, or the combination of D-Mic and DNR on acceptance of noise and preference when listening in various types of background noise. An experimental study in which subjects were exposed to a repeated measures design was utilized. Thirty adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Acceptable noise levels (ANLs) were obtained using no noise reduction technologies, D-Mic only, DNR only, and the combination of the two technologies (Combo) for three different background noises (single-talker speech, speech-shaped noise, and multitalker babble) for each listener. In addition, preference rankings of the noise reduction technologies were obtained within each background noise (1 = best, 3 = worst). ANL values were significantly better for each noise reduction technology than baseline; and benefit increased significantly from DNR to D-Mic to Combo. Listeners with higher (worse) baseline ANLs received more benefit from noise reduction technologies than listeners with lower (better) baseline ANLs. Neither ANL values nor ANL benefit values were significantly affected by background noise type; however, ANL benefit with D-Mic and Combo was similar when speech-like noise was present while ANL benefit was greatest for Combo when speech spectrum noise was

  12. A Challenge to Improve High-Temperature Platinum Resistance Thermometer

    Science.gov (United States)

    Tanaka, Y.; Widiatmo, J. V.; Harada, K.; Kobayashi, T.; Yamazawa, K.

    2017-05-01

    High-temperature standard platinum resistance thermometers (HTSPRTs) are used to interpolate the international temperature scale of 1990 (ITS-90), especially for temperatures between the aluminum and the silver points. For this, long-term stability of the HTSPRT is essential. CHINO R800-3L type SPRT, which has a nominal resistance at the triple point of water (TPW) around 0.25 Ω , is the one developed earlier for the interpolation of the ITS-90 at this temperature range. Further development to this previous model has been carried out for the purpose of improving the thermal stability. The improvement was focused on reducing the effect coming from the difference in thermal expansion between platinum wire and the quartz frame on which the platinum wire is installed. New HTSPRTs were made by CHINO Corporation. Some series of tests were carried out at CHINO and at NMIJ. Initial tests after the HTSPRT fabrication were done at CHINO, where thermal cycles between 500°C and 980°C were applied to the HTSPRTs to see change in the resistances at the TPW (R_{TPW}) and at the gallium point (R_{Ga}). Repeated resistance measurements at the silver point (R_{Ag}) were performed after completing the thermal cycling test. Before and after every measurement at silver point, R_{TPW} was measured, while before and after every two silver point realization R_{Ga} were measured. After completing this test, the HTSPRTs were transported to NMIJ, where the same repeated measurements at the silver point were done at NMIJ. These were then repeated at CHINO and at NMIJ upon repeated transportation among the institutes, to evaluate some effect due to transportation. This paper reports the details of the above-mentioned tests, the results and the analysis.

  13. Community noise

    Science.gov (United States)

    Bragdon, C. R.

    Airport and community land use planning as they relate to airport noise reduction are discussed. Legislation, community relations, and the physiological effect of airport noise are considered. Noise at the Logan, Los Angeles, and Minneapolis/St. Paul airports is discussed.

  14. Dynamical symmetry breaking in the Jackiw-Johnson model and the gauge technique

    International Nuclear Information System (INIS)

    Singh, J.P.

    1984-01-01

    The Jackiw-Johnson model of dynamical gauge symmetry breaking has been re-examined in the light of the gauge technique. In the limit where the ratio of the axial to vector coupling constants becomes small, or, consistently, in the limit where the ratio of the axial-vector-boson mass to the fermion mass becomes small, an approximate solution for the fermion spectral function has been derived. This gives an extremely small ratio of the axial-vector-boson mass to the fermion mass. (author)

  15. Quality of streams in Johnson County, Kansas, 2002--10

    Science.gov (United States)

    Rasmussen, Teresa J.; Stone, Mandy S.; Poulton, Barry C.; Graham, Jennifer L.

    2012-01-01

    Stream quality in Johnson County, northeastern Kansas, was assessed on the basis of land use, hydrology, stream-water and streambed-sediment chemistry, riparian and in-stream habitat, and periphyton and macroinvertebrate community data collected from 22 sites during 2002 through 2010. Stream conditions at the end of the study period are evaluated and compared to previous years, stream biological communities and physical and chemical conditions are characterized, streams are described relative to Kansas Department of Health and Environment impairment categories and water-quality standards, and environmental factors that most strongly correlate with biological stream quality are evaluated. The information is useful for improving water-quality management programs, documenting changing conditions with time, and evaluating compliance with water-quality standards, total maximum daily loads (TMDLs), National Pollutant Discharge Elimination System (NPDES) permit conditions, and other established guidelines and goals. Constituent concentrations in water during base flow varied across the study area and 2010 conditions were not markedly different from those measured in 2003, 2004, and 2007. Generally the highest specific conductance and concentrations of dissolved solids and major ions in water occurred at urban sites except the upstream Cedar Creek site, which is rural and has a large area of commercial and industrial land less than 1 mile upstream on both sides of the creek. The highest base-flow nutrient concentrations in water occurred downstream from wastewater treatment facilities. Water chemistry data represent base-flow conditions only, and do not show the variability in concentrations that occurs during stormwater runoff. Constituent concentrations in streambed sediment also varied across the study area and some notable changes occurred from previously collected data. High organic carbon and nutrient concentrations at the rural Big Bull Creek site in 2003 decreased

  16. Obituary Betty Johnson - tireless advocate for woment to pursue - and return to - scientific careers

    CERN Multimedia

    Perry, K

    2003-01-01

    "The physicist Professor Elizabeth (Betty) Johnson, who has died aged 66, was a major force in the establishment of the Daphne Jackson Trust in 1992 to help women returning to science after a career break. She worked tirelessly to encourage women into science, both through her own example as a female scientist and her advocacy of science as a career" (1/2 page).

  17. Noise Estimation and Quality Assessment of Gaussian Noise Corrupted Images

    Science.gov (United States)

    Kamble, V. M.; Bhurchandi, K.

    2018-03-01

    Evaluating the exact quantity of noise present in an image and quality of an image in the absence of reference image is a challenging task. We propose a near perfect noise estimation method and a no reference image quality assessment method for images corrupted by Gaussian noise. The proposed methods obtain initial estimate of noise standard deviation present in an image using the median of wavelet transform coefficients and then obtains a near to exact estimate using curve fitting. The proposed noise estimation method provides the estimate of noise within average error of +/-4%. For quality assessment, this noise estimate is mapped to fit the Differential Mean Opinion Score (DMOS) using a nonlinear function. The proposed methods require minimum training and yields the noise estimate and image quality score. Images from Laboratory for image and Video Processing (LIVE) database and Computational Perception and Image Quality (CSIQ) database are used for validation of the proposed quality assessment method. Experimental results show that the performance of proposed quality assessment method is at par with the existing no reference image quality assessment metric for Gaussian noise corrupted images.

  18. Report on inter-noise 99; Inter-noise 99 sanka hokok

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    2000-04-01

    Inter-Noise (International Congress on Noise Control Engineering) is a society on noise/vibration and the control technology. Inter-Noise 99 was held on December 6, 7 and 8, 1999, at Fort Lauderdale, Florida, the U.S. The theme was Noise Control in the New Millennium. The number of the participants registered was 555 (151 from the U.S., 89 from Japan, 248 from European countries, and 69 from Asian/other countries). Dr. Harold Marshall gave a keynote lecture titled Noise Control by Design in the 21st Century - An Architectural Acoustic Perspective. From a standpoint of architectural acoustics, he stated the perspective, subjects, and course of the technical development pertaining to technologies needed in the 21st century. The papers read are mostly from the following fields: measuring technology, military exercise noise, modeling, forecast and simulation, aerodynamic/underwater sound, etc. In the session on the tire noise where the author read a paper, 14 papers were read. The number of the papers read was more than that in 1998, probably influenced by the tire noise regulation in Europe and Japan. (translated by NEDO)

  19. Noise frame duration, masking potency and whiteness of temporal noise

    OpenAIRE

    Kukkonen, Helja; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antii

    2002-01-01

    PURPOSE. Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. \\ud \\ud METHODS. Contrast energy thresho...

  20. Noise

    Science.gov (United States)

    Noise is all around you, from televisions and radios to lawn mowers and washing machines. Normally, you ... sensitive structures of the inner ear and cause noise-induced hearing loss. More than 30 million Americans ...

  1. Nanomaterials Work at NASA-Johnson Space Center

    Science.gov (United States)

    Arepalli, Sivaram

    2005-01-01

    Nanomaterials activities at NASA-Johnson Space Center focus on single wall carbon nanotube production, characterization and their applications for aerospace. Nanotubes are produced by arc and laser methods and the growth process is monitored by in-situ diagnostics using time resolved passive emission and laser induced fluorescence of the active species. Parametric study of both these processes are conducted to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, laser fluence and arc current. Characterization of the nanotube material is performed using the NASA-JSC protocol developed by combining analytical techniques of SEM, TEM, UV-VIS-NIR absorption, Raman, and TGA. Efforts at JSC over the past five years in composites have centered on structural polymernanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large surface area as well as high conductivity exhibited by SWCNTs.

  2. The role of Urbis' noise and noise effects maps in local policy

    NARCIS (Netherlands)

    Borst, H.C.

    2001-01-01

    An important aspect of the EU noise policy is mapping of noise and noise effects and the formulation of noise action plans. In the Netherlands, due to the new policy on noise (MIG), the municipalities will be responsible for the formulation of a local noise policy. An instrument for the assessment

  3. Noise in Optical Amplifiers

    DEFF Research Database (Denmark)

    Jeppesen, Palle

    1997-01-01

    Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived.......Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived....

  4. White Anglo-Saxon hopes and black Americans' Atlantic dreams: Jack Johnson and the British boxing colour bar.

    Science.gov (United States)

    Runstedtler, Theresa

    2010-01-01

    This article examines the controversy surrounding Jack Johnson's proposed world heavyweight title fight against the British champion Bombardier Billy Wells in London (1911). In juxtaposing African Americans' often glowing discussions of European tolerance with the actual white resistance the black champion faced in Britain, including the Home Office's eventual prohibition of the match, the article explores the period's transnational discourses of race and citizenship. Indeed, as white sportsmen on both sides of the Atlantic joined together in their search for a "White Hope" to unseat Johnson, the boxing ring became an important cultural arena for interracial debates over the political and social divisions between white citizens and nonwhite subjects. Although African Americans had high hopes for their hero's European sojourn, the British backlash against the Johnson-Wells match underscored the fact that their local experiences of racial oppression were just one facet of a much broader global problem. At the same time, the proposed prizefight also made the specter of interracial conflict in the colonies all the more tangible in the British capital, provoking public discussions about the merits of U.S. racial segregation, along with the need for white Anglo-Saxon solidarity around the world. Thus, this article not only exposes the underlying connections between American Jim Crow and the racialized fault lines of British imperialism, but it also traces the "tense and tender ties" linking U.S. and African American history with the new imperial history and postcolonial studies.

  5. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  6. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  7. Síndrome de Stevens-Johnson: presentación de un caso

    OpenAIRE

    Fernández Brizuela, Ener de Jesús; Morales Díaz, Felicia

    2011-01-01

    Fundamento: el síndrome de Stevens-Johnson, también llamado eritema multiforme mayor, se caracteriza por una serie de lesiones cutáneas de diversa morfología, es una grave lesión en la cual están afectadas al menos dos membranas mucosas y la piel. La patogenia de esta enfermedad es desconocida aunque generalmente se considera que es provocada por una reacción de hipersensibilidad a drogas, infecciones y exposición a sustancias tóxicas. Caso clínico: esta afección fue diagnosticada en un niño ...

  8. Conceptual Inadequacy of the Shore and Johnson Axioms for Wide Classes of Complex Systems

    Directory of Open Access Journals (Sweden)

    Constantino Tsallis

    2015-05-01

    Full Text Available It is by now well known that the Boltzmann-Gibbs-von Neumann-Shannon logarithmic entropic functional (\\(S_{BG}\\ is inadequate for wide classes of strongly correlated systems: see for instance the 2001 Brukner and Zeilinger's {\\it Conceptual inadequacy of the Shannon information in quantum measurements}, among many other systems exhibiting various forms of complexity. On the other hand, the Shannon and Khinchin axioms uniquely mandate the BG form \\(S_{BG}=-k\\sum_i p_i \\ln p_i\\; the Shore and Johnson axioms follow the same path. Many natural, artificial and social systems have been satisfactorily approached with nonadditive entropies such as the \\(S_q=k \\frac{1-\\sum_i p_i^q}{q-1}\\ one (\\(q \\in {\\cal R}; \\,S_1=S_{BG}\\, basis of nonextensive statistical mechanics. Consistently, the Shannon 1948 and Khinchine 1953 uniqueness theorems have already been generalized in the literature, by Santos 1997 and Abe 2000 respectively, in order to uniquely mandate \\(S_q\\. We argue here that the same remains to be done with the Shore and Johnson 1980 axioms. We arrive to this conclusion by analyzing specific classes of strongly correlated complex systems that await such generalization.

  9. Band gap calculations of the semiconductor BNxP1−x using modified Becke–Johnson approximation

    International Nuclear Information System (INIS)

    Benkraouda, M.; Amrane, N.

    2013-01-01

    Highlights: ► The Modified Becke–Johnson scheme gives a very accurate band gap. ► We have shown the invalidity of Vegard’s linear rule for BN x P 1−x . ► The band gap changes with alloy concentration are important in band gap engineering. - Abstract: In this work, the electronic properties of BN, BP and BN x P 1−x compounds have been investigated by means of first-principles density-functional total-energy calculation using the all-electron full potential linear augmented plane-wave method (FP-LAPW). The (FP-LAPW) method was used within the density functional theory (DFT) along with the Engel–Vosko and Becke–Johnson exchange correlation potential. The energy bands along high symmetry directions, the density of states and bowing distributions are calculated. The results have been discussed in terms of previously existing experimental and theoretical data, and comparisons with similar compounds have been made. Analysis of band structure suggests direct and pseudo-direct band gaps for both compounds.

  10. Adaptive EMG noise reduction in ECG signals using noise level approximation

    Science.gov (United States)

    Marouf, Mohamed; Saranovac, Lazar

    2017-12-01

    In this paper the usage of noise level approximation for adaptive Electromyogram (EMG) noise reduction in the Electrocardiogram (ECG) signals is introduced. To achieve the adequate adaptiveness, a translation-invariant noise level approximation is employed. The approximation is done in the form of a guiding signal extracted as an estimation of the signal quality vs. EMG noise. The noise reduction framework is based on a bank of low pass filters. So, the adaptive noise reduction is achieved by selecting the appropriate filter with respect to the guiding signal aiming to obtain the best trade-off between the signal distortion caused by filtering and the signal readability. For the evaluation purposes; both real EMG and artificial noises are used. The tested ECG signals are from the MIT-BIH Arrhythmia Database Directory, while both real and artificial records of EMG noise are added and used in the evaluation process. Firstly, comparison with state of the art methods is conducted to verify the performance of the proposed approach in terms of noise cancellation while preserving the QRS complex waves. Additionally, the signal to noise ratio improvement after the adaptive noise reduction is computed and presented for the proposed method. Finally, the impact of adaptive noise reduction method on QRS complexes detection was studied. The tested signals are delineated using a state of the art method, and the QRS detection improvement for different SNR is presented.

  11. The Assessment of Noise Exposure and Noise Annoyance at a Petrochemical Company

    Directory of Open Access Journals (Sweden)

    S. Farhang Dehghan

    2013-12-01

    .Conclusion: Based on the obtained results of investigating the noise level (objective exposure as well as the noise annoyance (subjective exposure at the studied company, it is necessary to adopt the management –technical noise reduction measures at manufacturing sectors as the personal noise exposure and environmental noise exposure and also noise personal exposure of administrative staff can be decreased.

  12. Development of the CELSS emulator at NASA. Johnson Space Center

    Science.gov (United States)

    Cullingford, Hatice S.

    1990-01-01

    The Closed Ecological Life Support System (CELSS) Emulator is under development. It will be used to investigate computer simulations of integrated CELSS operations involving humans, plants, and process machinery. Described here is Version 1.0 of the CELSS Emulator that was initiated in 1988 on the Johnson Space Center (JSC) Multi Purpose Applications Console Test Bed as the simulation framework. The run model of the simulation system now contains a CELSS model called BLSS. The CELSS simulator empowers us to generate model data sets, store libraries of results for further analysis, and also display plots of model variables as a function of time. The progress of the project is presented with sample test runs and simulation display pages.

  13. Noise pollution resources compendium

    Science.gov (United States)

    1973-01-01

    Abstracts of reports concerning noise pollution are presented. The abstracts are grouped in the following areas of activity: (1) sources of noise, (2) noise detection and measurement, (3) noise abatement and control, (4) physical effects of noise and (5) social effects of noise.

  14. Solar noise storms

    CERN Document Server

    Elgaroy, E O

    2013-01-01

    Solar Noise Storms examines the properties and features of solar noise storm phenomenon. The book also presents some theories that can be used to gain a better understanding of the phenomenon. The coverage of the text includes topics that cover the features and behavior of noise storms, such as the observable features of noise storms; the relationship between noise storms and the observable features on the sun; and ordered behavior of storm bursts in the time-frequency plane. The book also covers the spectrum, polarization, and directivity of noise storms. The text will be of great use to astr

  15. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  16. Proceedings of the 2009 spring noise conference : noise awareness : supporting sound partnerships

    International Nuclear Information System (INIS)

    2009-01-01

    This conference provided a forum for industry, government, public, academics and acoustical professionals to discuss innovations in environmental and occupational noise identification, measurement, regulation and control. In addition to raising awareness about expanding noise issues, the conference objectives were to promote responsible industrial development and to identify strategies for reducing workplace noise exposure. The papers focused on research, developments and case studies and highlighted current issues and advancements in technology and software. Speakers from around the world discussed topics ranging from occupational noise issues to low frequency. The 8 sessions were entitled: (1) plenary session, (2) architecture, community planning and public health: effects of noise and noise control, (3) modeling, measurement and technology; (4) noise awareness and education: public, occupational and industrial, (5) regulations and economics: bylaws, legislation and the economics of noise control; (6) student papers, (7) vibration, industrial noise, transportation noise and occupational noise control, and (8) lunch speakers. The conference featured 46 presentations, of which 19 have been catalogued separately for inclusion in this database. refs., tabs., figs.

  17. Noise in strong laser-atom interactions: Phase telegraph noise

    International Nuclear Information System (INIS)

    Eberly, J.H.; Wodkiewicz, K.; Shore, B.W.

    1984-01-01

    We discuss strong laser-atom interactions that are subjected to jump-type (random telegraph) random-phase noise. Physically, the jumps may arise from laser fluctuations, from collisions of various kinds, or from other external forces. Our discussion is carried out in two stages. First, direct and partially heuristic calculations determine the laser spectrum and also give a third-order differential equation for the average inversion of a two-level atom on resonance. At this stage a number of general features of the interaction are able to be studied easily. The optical analog of motional narrowing, for example, is clearly predicted. Second, we show that the theory of generalized Poisson processes allows laser-atom interactions in the presence of random telegraph noise of all kinds (not only phase noise) to be treated systematically, by means of a master equation first used in the context of quantum optics by Burshtein. We use the Burshtein equation to obtain an exact expression for the two-level atom's steady-state resonance fluorescence spectrum, when the exciting laser exhibits phase telegraph noise. Some comparisons are made with results obtained from other noise models. Detailed treatments of the effects ofmly jumps, or as a model of finite laser bandwidth effects, in which the laser frequency exhibits random jumps. We show that these two types of frequency noise can be distinguished in light-scattering spectra. We also discuss examples which demonstrate both temporal and spectral motional narrowing, nonexponential correlations, and non-Lorentzian spectra. Its exact solubility in finite terms makes the frequency-telegraph noise model an attractive alternative to the white-noise Ornstein-Uhlenbeck frequency noise model which has been previously applied to laser-atom interactions

  18. Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

    Science.gov (United States)

    Spalt, Taylor B.; Brooks, Thomas F.; Fuller, Christopher R.

    2012-01-01

    Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

  19. Classical noise, quantum noise and secure communication

    International Nuclear Information System (INIS)

    Tannous, C; Langlois, J

    2016-01-01

    Secure communication based on message encryption might be performed by combining the message with controlled noise (called pseudo-noise) as performed in spread-spectrum communication used presently in Wi-Fi and smartphone telecommunication systems. Quantum communication based on entanglement is another route for securing communications as demonstrated by several important experiments described in this work. The central role played by the photon in unifying the description of classical and quantum noise as major ingredients of secure communication systems is highlighted and described on the basis of the classical and quantum fluctuation dissipation theorems. (review)

  20. A comparison of estimation methods for fitting Weibull, Johnson's SB and beta functions to Pinus pinaster, Pinus radiata and Pinus sylvestris stands in northwest Spain

    Energy Technology Data Exchange (ETDEWEB)

    Gorgoseo, J. J.; Rojo, A.; Camara-Obregon, A.; Dieguez-Aranda, U.

    2012-07-01

    The purpose of this study was to compare the accuracy of the Weibull, Johnson's SB and beta distributions, fitted with some of the most usual methods and with different fixed values for the location parameters, for describing diameter distributions in even-aged stands of Pinus pinaster, Pinus radiata and Pinus sylvestris in northwest Spain. A total of 155 permanent plots in Pinus sylvestris stands throughout Galicia, 183 plots in Pinus pinaster stands throughout Galicia and Asturias and 325 plots in Pinus radiata stands in both regions were measured to describe the diameter distributions. Parameters of the Weibull function were estimated by Moments and Maximum Likelihood approaches, those of Johnson's SB function by Conditional Maximum Likelihood and by Knoebel and Burkhart's method, and those of the beta function with the method based on the moments of the distribution. The beta and the Johnson's SB functions were slightly superior to Weibull function for Pinus pinaster stands; the Johnson's SB and beta functions were more accurate in the best fits for Pinus radiata stands, and the best results of the Weibull and the Johnson's SB functions were slightly superior to beta function for Pinus sylvestris stands. However, the three functions are suitable for this stands with an appropriate value of the location parameter and estimation of parameters method. (Author) 44 refs.

  1. Os relatórios Masters & Johnson: gênero e as práticas psicoterapêuticas sexuais a partir da década de 70 The Masters & Johnson's reports: gender and the sexual psychotherapy practices as of the 1970s

    Directory of Open Access Journals (Sweden)

    Tito Sena

    2010-04-01

    Full Text Available Este trabalho é o resultado de uma análise sobre os relatórios Masters & Johnson, editados originalmente nos anos de 1966 (A Resposta Sexual Humana e 1970 (A Inadequação Sexual Humana. Os relatórios analisados, produzidos nos Estados Unidos e com repercussão mundial, foram elaborados a partir de uma minuciosa investigação científica das respostas fisiológicas e anatômicas da sexualidade masculina e feminina. Os autores, em decorrência, utilizaram esses conhecimentos para a formulação de técnicas e tratamento em terapia sexual utilizadas até hoje por profissionais da área clínica. Os relatórios Masters & Johnson emergiram com a proposta de preencher as lacunas médicas, fisiológicas e psicológicas diante das pesquisas estatísticas comportamentais de Alfred Kinsey (1948 e 1953. A obra de M&J se apresenta abertamente como uma defesa do casamento monogâmico heterossexual, e com elaborações atravessadas por questões de gênero. Partindo do instrumental teórico de Michel Foucault, verifica-se serem exemplares da prática de uma scientia sexualis, que procura instituir uma verdade no sexo e do sexo.This work is the result of an analysis on the Masters & Johnson's Reports, originally published in 1966 (Human Sexual Response and 1970 (The Human Sexual Inadequacy. The reports investigated, produced in the United States and spread worldwide, were prepared based on a careful, scientific investigation of the physiologic and anatomic responses of male and female sexuality. The authors used the results to formulate techniques and treatment in sexual therapy, which are so far in use by professionals in the clinical area. The Masters & Johnson's reports came with the proposal of filling the medical, physiological and psychological gaps left by the behaviorist statistics research by Alfred Kinsey (1948 and 1953. M&J's work defends openly the heterosexual monogamist marriage, with elaborations mingled with gender questions. From the

  2. Concurrent Validity of the Woodcock-Johnson Tests of Cognitive Ability with the WISC-R: EMR Children.

    Science.gov (United States)

    Cummings, Jack A.; Sanville, David

    1983-01-01

    Administered the Wechsler Intelligence Scale for Children-Revised (WISC-R) and the Woodcock-Johnson Tests of Cognitive Ability (WJTCA) to educable mentally retarded children (N=30). Results showed significant mean differences between WISC-R and WJTCA full-scale standard scores, providing implications for placement of children in classes for the…

  3. Definition of 1992 Technology Aircraft Noise Levels and the Methodology for Assessing Airplane Noise Impact of Component Noise Reduction Concepts

    Science.gov (United States)

    Kumasaka, Henry A.; Martinez, Michael M.; Weir, Donald S.

    1996-01-01

    This report describes the methodology for assessing the impact of component noise reduction on total airplane system noise. The methodology is intended to be applied to the results of individual study elements of the NASA-Advanced Subsonic Technology (AST) Noise Reduction Program, which will address the development of noise reduction concepts for specific components. Program progress will be assessed in terms of noise reduction achieved, relative to baseline levels representative of 1992 technology airplane/engine design and performance. In this report, the 1992 technology reference levels are defined for assessment models based on four airplane sizes - an average business jet and three commercial transports: a small twin, a medium sized twin, and a large quad. Study results indicate that component changes defined as program final goals for nacelle treatment and engine/airframe source noise reduction would achieve from 6-7 EPNdB reduction of total airplane noise at FAR 36 Stage 3 noise certification conditions for all of the airplane noise assessment models.

  4. Rating environmental noise on the basis of noise maps

    NARCIS (Netherlands)

    Miedema, H.M.E.; Borst, H.C.

    2006-01-01

    A system that rates noise on the basis of noise maps has been developed which is based on empirical exposure-response relationships, so that effects in the community will be lower if the system gives a better rating. It is consistent with noise metrics and effect endpoint chosen in the EU, i.e., it

  5. Yesterday's noise - today's signal

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1978-01-01

    Plant performance can be improved by noise analysis. This paper describes noise characteristics, imposed noise and response functions, a case history of cost benefits derived from application of noise analysis techniques, areas for application of noise analysis techniques with special reference to the Gentilly-1 nuclear generating station, and the validity of noise measurement results. (E.C.B.)

  6. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  7. Wide-band CMOS low-noise amplifier exploiting thermal noise canceling

    OpenAIRE

    Bruccoleri, F.; Klumperink, Eric A.M.; Nauta, Bram

    2004-01-01

    Known elementary wide-band amplifiers suffer from a fundamental tradeoff between noise figure (NF) and source impedance matching, which limits the NF to values typically above 3 dB. Global negative feedback can be used to break this tradeoff, however, at the price of potential instability. In contrast, this paper presents a feedforward noise-canceling technique, which allows for simultaneous noise and impedance matching, while canceling the noise and distortion contributions of the matching d...

  8. Magnetic Nanoparticle Thermometer: An Investigation of Minimum Error Transmission Path and AC Bias Error

    Directory of Open Access Journals (Sweden)

    Zhongzhou Du

    2015-04-01

    Full Text Available The signal transmission module of a magnetic nanoparticle thermometer (MNPT was established in this study to analyze the error sources introduced during the signal flow in the hardware system. The underlying error sources that significantly affected the precision of the MNPT were determined through mathematical modeling and simulation. A transfer module path with the minimum error in the hardware system was then proposed through the analysis of the variations of the system error caused by the significant error sources when the signal flew through the signal transmission module. In addition, a system parameter, named the signal-to-AC bias ratio (i.e., the ratio between the signal and AC bias, was identified as a direct determinant of the precision of the measured temperature. The temperature error was below 0.1 K when the signal-to-AC bias ratio was higher than 80 dB, and other system errors were not considered. The temperature error was below 0.1 K in the experiments with a commercial magnetic fluid (Sample SOR-10, Ocean Nanotechnology, Springdale, AR, USA when the hardware system of the MNPT was designed with the aforementioned method.

  9. Geology and mineral resources of the Johnson City, Phenix City, and Rome 10 x 20 NTMS quadrangles

    International Nuclear Information System (INIS)

    Karfunkel, B.S.

    1981-11-01

    This document provides geologic and mineral resources data for the Savannah River Laboratory-National Uranium Resource Evaluation hydrogeochemical and stream-sediment reports for the Johnson City, Phenix City, and Rome 1 0 x 2 0 National Topographic Map Series quadrangles in the southeastern United States

  10. Combat aircraft noise

    Science.gov (United States)

    Sgarbozza, M.; Depitre, A.

    1992-04-01

    A discussion of the characteristics and the noise levels of combat aircraft and of a transport aircraft in taking off and landing are presented. Some methods of noise reduction are discussed, including the following: operational anti-noise procedures; and concepts of future engines (silent post-combustion and variable cycle). Some measurement results concerning the noise generated in flight at great speeds and low altitude will also be examined. Finally, the protection of the environment of French air bases against noise will be described and the possibilities of regulation examined.

  11. Field building: lessons from the Robert Wood Johnson Foundation's anthology series.

    Science.gov (United States)

    Isaacs, Stephen L; Knickman, James R

    2005-01-01

    As editors of the Robert Wood Johnson Foundation's (RWJF's) anthology series, we have examined the entire range of the foundation's grant making since 1972. We found that the RWJF has enjoyed considerable success in building fields--from nurse practitioners to tobacco control to end-of-life care. The RWJF has done this by shaping fields as they were emerging, by adopting a wide-ranging "bear hug" approach, and by staying the course. The lessons from the RWJF's field-building efforts are relevant for both large and small foundations: Small funders can develop strategic plans aimed at building fields in their home state or locality.

  12. Listen to the noise: noise is beneficial for cognitive performance in ADHD.

    Science.gov (United States)

    Söderlund, Göran; Sikström, Sverker; Smart, Andrew

    2007-08-01

    Noise is typically conceived of as being detrimental to cognitive performance. However, given the mechanism of stochastic resonance, a certain amount of noise can benefit performance. We investigate cognitive performance in noisy environments in relation to a neurocomputational model of attention deficit hyperactivity disorder (ADHD) and dopamine. The Moderate Brain Arousal model (MBA; Sikström & Söderlund, 2007) suggests that dopamine levels modulate how much noise is required for optimal cognitive performance. We experimentally examine how ADHD and control children respond to different encoding conditions, providing different levels of environmental stimulation. Participants carried out self-performed mini tasks (SPT), as a high memory performance task, and a verbal task (VT), as a low memory task. These tasks were performed in the presence, or absence, of auditory white noise. Noise exerted a positive effect on cognitive performance for the ADHD group and deteriorated performance for the control group, indicating that ADHD subjects need more noise than controls for optimal cognitive performance. The positive effect of white noise is explained by the phenomenon of stochastic resonance (SR), i.e., the phenomenon that moderate noise facilitates cognitive performance. The MBA model suggests that noise in the environment, introduces internal noise into the neural system through the perceptual system. This noise induces SR in the neurotransmitter systems and makes this noise beneficial for cognitive performance. In particular, the peak of the SR curve depends on the dopamine level, so that participants with low dopamine levels (ADHD) require more noise for optimal cognitive performance compared to controls.

  13. Prewhitening for Rank-Deficient Noise in Subspace Methods for Noise Reduction

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    2005-01-01

    A fundamental issue in connection with subspace methods for noise reduction is that the covariance matrix for the noise is required to have full rank, in order for the prewhitening step to be defined. However, there are important cases where this requirement is not fulfilled, e.g., when the noise...... has narrow-band characteristics, or in the case of tonal noise. We extend the concept of prewhitening to include the case when the noise covariance matrix is rank deficient, using a weighted pseudoinverse and the quotient SVD, and we show how to formulate a general rank-reduction algorithm that works...... also for rank deficient noise. We also demonstrate how to formulate this algorithm by means of a quotient ULV decomposition, which allows for faster computation and updating. Finally we apply our algorithm to a problem involving a speech signal contaminated by narrow-band noise....

  14. BWR noise spectra and application of noise analysis to FBR

    International Nuclear Information System (INIS)

    Nomura, T.

    1975-01-01

    Work related to noise analysis, in Tokyo Shibaura Electric Co. Ltd. (Toshiba) and Nippon Atomic Industry Group Co. Ltd. (NAIG) for the past several years is reviewed. After considering the Japan-United States Seminar on Reactor Noise Analysis in 1968, other subjects discussed were boiling water reactor noise analysis and work in relation to FBR. Parts of these are related to each other. For example, boiling detection and temperature fluctuations are problems pertinent to both fields. As the main problems in zero-power-reactor noise are now basically understood, only a brief description of the experiments involving the advanced two detector method is made. Focus is rather placed on the area of power plant noise. (author)

  15. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  16. SHORT COMMUNICATION: Correlation between the Resistance Ratios of Platinum Resistance Thermometers at the Melting Point of Gallium and the Triple Point of Mercury

    Science.gov (United States)

    Singh, Y. P.; Maas, H.; Edler, F.; Zaidi, Z. H.

    1994-01-01

    A set of resistance ratios (W) for platinum resistance thermometers was obtained at the triple point of Hg and the melting point of Ga in order to study their relationship. It was found that using measured values for one of the fixed points, a linear equation will predict the value of the other. These measurements also indicate that the fixed points of Hg and of Ga are inconsistent by about 1,5 mK in the sense that either the melting point of Ga or the triple point of Hg was assigned too high a value on the ITS-90.

  17. Noise sensitivity and reactions to noise and other environmental conditions

    NARCIS (Netherlands)

    Miedema, H.M.E.; Vos, H.

    2003-01-01

    This article integrates findings from the literature and new results regarding noise sensitivity. The new results are based on analyses of 28 combined datasets (N=23 038), and separate analyses of a large aircraft noise study (N=10939). Three topics regarding noise sensitivity are discussed, namely,

  18. Adaptive noise cancellation

    International Nuclear Information System (INIS)

    Akram, N.

    1999-01-01

    In this report we describe the concept of adaptive noise canceling, an alternative method of estimating signals corrupted by additive noise of interference. The method uses 'primary' input containing the corrupted signal and a 'reference' input containing noise correlated in some unknown way with the primary noise, the reference input is adaptively filtered and subtracted from the primary input to obtain the signal estimate. Adaptive filtering before subtraction allows the treatment of inputs that are deterministic or stochastic, stationary or time variable. When the reference input is free of signal and certain other conditions are met then noise in the primary input can be essentially eliminated without signal distortion. It is further shown that the adaptive filter also acts as notch filter. Simulated results illustrate the usefulness of the adaptive noise canceling technique. (author)

  19. Critical Low-Noise Technologies Being Developed for Engine Noise Reduction Systems Subproject

    Science.gov (United States)

    Grady, Joseph E.; Civinskas, Kestutis C.

    2004-01-01

    NASA's previous Advanced Subsonic Technology (AST) Noise Reduction Program delivered the initial technologies for meeting a 10-year goal of a 10-dB reduction in total aircraft system noise. Technology Readiness Levels achieved for the engine-noise-reduction technologies ranged from 4 (rig scale) to 6 (engine demonstration). The current Quiet Aircraft Technology (QAT) project is building on those AST accomplishments to achieve the additional noise reduction needed to meet the Aerospace Technology Enterprise's 10-year goal, again validated through a combination of laboratory rig and engine demonstration tests. In order to meet the Aerospace Technology Enterprise goal for future aircraft of a 50- reduction in the perceived noise level, reductions of 4 dB are needed in both fan and jet noise. The primary objectives of the Engine Noise Reduction Systems (ENRS) subproject are, therefore, to develop technologies to reduce both fan and jet noise by 4 dB, to demonstrate these technologies in engine tests, and to develop and experimentally validate Computational Aero Acoustics (CAA) computer codes that will improve our ability to predict engine noise.

  20. Johnson-Laird's mental models theory and its principles: an application with cell mental models of high school students

    OpenAIRE

    Mª Luz Rodríguez Palmero; Javier Marrero Acosta; Marco Antonio Moreira

    2001-01-01

    Following a discussion of Johnson-Laird's mental models theory, we report a study regarding high school students mental representations of cell, understood as mental models. Research findings suggest the appropriatedness of such a theory as a framework to interpret students' representations.

  1. Phenomenon of entropic stochastic resonance with asymmetric dichotomous noise and white noise

    International Nuclear Information System (INIS)

    Guo, Feng; Li, Shao-Fu; Cheng, Xiao-Feng

    2012-01-01

    The entropic stochastic resonance (ESR) in a confined system subject to asymmetric dichotomous noise, white noise, and a periodic square-wave signal is investigated. Under the adiabatic approximation condition, by use of the properties of the dichotomous noise, we obtain the expression of the output signal-to-noise ratio (SNR) based on two-state theory. The SNR is shown to be a nonmonotonic function of the strength and asymmetry of the dichotomous noise, the intensity of the white noise, and the amplitude of the square-wave signal. The SNR varies non-monotonically with increases in the parameters of the confined structure. The influence of the correlation rate of the dichotomous noise and the frequency of the external constant force on the SNR is also discussed.

  2. When noise is beneficial for sensory encoding: Noise adaptation can improve face processing.

    Science.gov (United States)

    Menzel, Claudia; Hayn-Leichsenring, Gregor U; Redies, Christoph; Németh, Kornél; Kovács, Gyula

    2017-10-01

    The presence of noise usually impairs the processing of a stimulus. Here, we studied the effects of noise on face processing and show, for the first time, that adaptation to noise patterns has beneficial effects on face perception. We used noiseless faces that were either surrounded by random noise or presented on a uniform background as stimuli. In addition, the faces were either preceded by noise adaptors or not. Moreover, we varied the statistics of the noise so that its spectral slope either matched that of the faces or it was steeper or shallower. Results of parallel ERP recordings showed that the background noise reduces the amplitude of the face-evoked N170, indicating less intensive face processing. Adaptation to a noise pattern, however, led to reduced P1 and enhanced N170 amplitudes as well as to a better behavioral performance in two of the three noise conditions. This effect was also augmented by the presence of background noise around the target stimuli. Additionally, the spectral slope of the noise pattern affected the size of the P1, N170 and P2 amplitudes. We reason that the observed effects are due to the selective adaptation of noise-sensitive neurons present in the face-processing cortical areas, which may enhance the signal-to-noise-ratio. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Croatian Experience in Road Traffic Noise Management - Concrete Noise Barriers

    Directory of Open Access Journals (Sweden)

    Ahac Saša

    2014-07-01

    Full Text Available The paper gives an overview of concrete noise barrier application in several EU countries and in Croatia. It describes a process of introducing different noise protection solutions on Croatian market in the phase of intensive motorway construction in recent years. Namely, an extensive motorway network has been constructed in Croatia in the last 10 years. Following the process of motorway construction, noise protection walls have also been erected. Usage of different building materials and installation processes as well as variations in building expenditures has led to a comparative analysis of several types of noise protection solutions (expanded clay, wood fibre including a new eco-innovative product RUCONBAR, which incorporates rubber granules from recycled waste tyres to form a porous noise absorptive layer.

  4. Effects of road traffic background noise on judgments of individual airplane noises. Ph.D. Thesis

    Science.gov (United States)

    Powell, C. A.

    1979-01-01

    Two laboratory experiments were conducted to investigate the effects of road-traffic background noise on judgments of individual airplane flyover noises. In the first experiment, 27 subjects judged a set of 16 airplane flyover noises in the presence of traffic-noise sessions of 30-min duration consisting of the combinations of 3 traffic-noise types and 3 noise levels. In the second experiment, 24 subjects judged the same airplane flyover noises in the presence of traffic-noise sessions of 10-min duration consisting of the combinations of 2 traffic-noise types and 4 noise levels. In both experiments the airplane noises were judged less annoying in the presence of high traffic-noise levels than in the presence of low traffic-noise levels.

  5. Low voltage excess noise and shot noise in YBCO bicrystal junctions

    DEFF Research Database (Denmark)

    Constantinian, K.Y.; Ovsyannikov, G.A.; Borisenko, I.V.

    2002-01-01

    The spectral density of background noise emitted by symmetric bicrystal YBaCuO Josephson junctions on sapphire substrates have been measured by a low noise cooled HEMT amplifier for bias voltages up to V approximate to 50 mV. At relatively low voltages V noise rise has been...... registered. At large bias voltages V > 30 mV a clear dependence of noise power. exactly coinciding to the asymptote of the Schottky shot noise function, has been observed for the first time. Experimental results are discussed in terms of multiple Andreev reflections which may take place in d...

  6. Indirect Combustion Noise: Noise Generation by Accelerated Vorticity in a Nozzle Flow

    Directory of Open Access Journals (Sweden)

    Nancy Kings

    2010-09-01

    Full Text Available The noise generation by accelerated vorticity waves in a nozzle flow was investigated in a model experiment. This noise generation mechanism belongs, besides entropy noise, to the indirect combustion noise phenomena. Vorticity as well as entropy fluctuations, originating from the highly turbulent combustion zone, are convected with the flow and produce noise during their acceleration in the outlet nozzle of the combustion chamber. In the model experiment, noise generation of accelerated vorticity fluctuations was achieved. The vorticity fluctuations in the tube flow were produced by injecting temporally additional air into the mean flow. As the next step, a parametric study was conducted to determine the major dependencies of the so called vortex noise. A quadratic dependency of the vortex noise on the injected air amount was found. In order to visualise and classify the artificially generated vorticity structures, planar velocity measurements have been conducted applying Particle Image Velocimetry (PIV.

  7. Development of Active Noise Control System for Quieting Transformer Noise

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bok Kyu; Song, Seik Young; Choi, Huo Yul [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Yun, Dae Hea; Lee, Hyuk Jae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1997-12-31

    The passive noise control technique made use of sound-absorbing or soundproofing materials, so it required a large area and high cost for installation and had a drawback of poor performance at low frequency. Compared to this, the Active Noise Control attenuates noise sound pressure by using secondary source which has same performance ay low-frequency. Furthermore, it is able to save space and expenses. - research on adaptive algorithms - evaluation of global attenuation of the control - computer simulation - real-time Active Noise Control System Hardware Implementation - ANC system setting in the noisy area.

  8. Mycoplasma pneumoniae-Induced-Stevens Johnson Syndrome: Rare Occurrence in an Adult Patient

    Directory of Open Access Journals (Sweden)

    Samad Rasul

    2012-01-01

    Full Text Available Stevens-Johnson syndrome (SJS is an uncommon occurrence in Mycoplasma pneumoniae (M. pneumoniae infection (1–5% and has been mainly reported in children and young adults. We present a case of SJS in a 32-year-old male induced by M. pneumoniae infection. This patient presented with fever, cough, and massive occupation of mucus membranes with swelling, erythema, and necrosis accompanied by a generalized cutaneous rash. He clinically responded after treatment with antibiotics and IVIG. SJS is usually a drug-induced condition; however, M. pneumoniae is the commonest infectious cause and should be considered in the differential diagnosis.

  9. Fast High-Quality Noise

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Wyvill, Geoff

    2007-01-01

    At the moment the noise functions available in a graphics programmer's toolbox are either slow to compute or they involve grid-line artifacts making them of lower quality. In this paper we present a real-time noise computation with no grid-line artifacts or other regularity problems. In other words......, we put a new tool in the box that computes fast high-quality noise. In addition to being free of artifacts, the noise we present does not rely on tabulated data (everything is computed on the fly) and it is easy to adjust quality vs. quantity for the noise. The noise is based on point rendering (like...... spot noise), but it extends to more than two dimensions. The fact that it is based on point rendering makes art direction of the noise much easier....

  10. Tracking of Nonstationary Noise Based on Data-Driven Recursive Noise Power Estimation

    NARCIS (Netherlands)

    Erkelens, J.S.; Heusdens, R.

    2008-01-01

    This paper considers estimation of the noise spectral variance from speech signals contaminated by highly nonstationary noise sources. The method can accurately track fast changes in noise power level (up to about 10 dB/s). In each time frame, for each frequency bin, the noise variance estimate is

  11. Extensions of the Johnson-Neyman Technique to Linear Models with Curvilinear Effects: Derivations and Analytical Tools

    Science.gov (United States)

    Miller, Jason W.; Stromeyer, William R.; Schwieterman, Matthew A.

    2013-01-01

    The past decade has witnessed renewed interest in the use of the Johnson-Neyman (J-N) technique for calculating the regions of significance for the simple slope of a focal predictor on an outcome variable across the range of a second, continuous independent variable. Although tools have been developed to apply this technique to probe 2- and 3-way…

  12. Erratum to ''Johnson's algorithm : A key to solve optimally or approximately flowshop scheduling problems with unavailability periods'' [International Journal of Production Economics 121 (2009) 81-87

    OpenAIRE

    Rapine , Christophe

    2013-01-01

    International audience; In Allaoui H., Artiba A, ''Johnson's algorithm : A key to solve optimally or approximately flowshop scheduling problems with unavailability periods'' [International Journal of Production Economics 121 (2009)] the authors propose optimality conditions for the Johnson sequence in presence of one unavailability period on the first machine and pretend for a performance guarantee of 2 when several unavailability periods may occur. We establish in this note that these condit...

  13. Use of the distress thermometer to evaluate symptoms, outcome and satisfaction in a specialist psycho-oncology service.

    Science.gov (United States)

    Blenkiron, Paul; Brooks, Alexander; Dearden, Richard; McVey, Joanne

    2014-01-01

    The National Institute for Health and Care Excellence recommends the use of structured tools to improve holistic care for patients with cancer. The Distress Thermometer and Problem Checklist (DT) is commonly used for screening in physical health settings. However, it has not been integrated into the clinical pathway within specialist psycho-oncology services. We used the DT to examine the broad clinical effectiveness of psycho-oncology intervention and to ascertain factors from the DT linked to an improved outcome. We also evaluated patients' satisfaction with their care. We asked 111 adult outpatients referred to York Psycho-Oncology Service to complete the DT at their first appointment. Individuals offered a period of psycho-oncology care re-rated their emotional distress, problems and service satisfaction on the DT at discharge. Median distress scores decreased significantly (from 6 to 4, Wilcoxon's z = -4.83, P psycho-oncology care. It may also provide evidence to support the effectiveness of specialist psycho-oncology interventions. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Final report on SIM.T-S2: Comparison of the calibration of 100 Ω platinum resistance thermometers

    Science.gov (United States)

    del Campo, D.; Chimenti Ruiz, V.; Méndez-Lango, E.; Córdova, L.; von Borries, E.; Sánchez, C. A.; Arévalo, A.; Aguilera, B.; Guillén, E.; Cabrera, C.; Quintana, L.

    2013-01-01

    An International Comparison on industrial platinum resistance thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Mexico and the Andean Countries (Bolivia, Colombia, Ecuador, Peru and Venezuela) began in 2004 and was successfully completed in 2005. Two PRTs were circulated (hand-carried) and compared from -40 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, was the pilot laboratory and the Centro Nacional de Metrología (Mexican NMI), CENAM, was the co-pilot laboratory. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Famous people with Tourette's syndrome: Dr. Samuel Johnson (yes) & Wolfgang Amadeus Mozart (may be): Victims of Tourette's syndrome?

    Science.gov (United States)

    Bhattacharyya, Kalyan B; Rai, Saurabh

    2015-01-01

    Tourette's syndrome is a clinical condition characterized by multiple motor tics and vocal tics which occurs in the age range 5-25 years and the intensity of the symptoms changes with time. It is felt that at least two remarkable personalities namely, Dr. Samuel Johnson from England, a man of letters and the compiler of the first ever English dictionary, and Wolfgang Amadeus Mozart from Austria, one of the greatest musical genius of all time, possibly suffered from this condition. Tourette's syndrome is often described as the classical borderzone between neurology and psychiatry and every neurologist wonders at the curious and fascinating clinical features of this condition. It seems that at least two remarkable personalities, Dr. Samuel Johnson, a man of letters and the first person to compile an English dictionary, and Wolfgang Amadeus Mozart, arguably the most creative musical composer of all time, were possibly afflicted with this condition.

  16. Stevens-Johnson syndrome and toxic epidermal necrolysis: an update on pharmacogenetics studies in drug-induced severe skin reaction.

    Science.gov (United States)

    Rufini, Sara; Ciccacci, Cinzia; Politi, Cristina; Giardina, Emiliano; Novelli, Giuseppe; Borgiani, Paola

    2015-11-01

    Stevens-Johnson syndrome and toxic epidermal necrolysis are severe, life-threatening drug reactions involving skin and membranes mucous, which are associated with significant morbidity and mortality and triggered, especially by drug exposure. Different studies have demonstrated that drug response is a multifactorial character and that the interindividual variability in this response depends on both environmental and genetic factors. The last ones have a relevant significance. In fact, the identification of new specific genetic markers involved in the response to drugs, will be of great utility to establish a more personalized therapeutic approach and to prevent the appearance of these adverse reactions. In this review, we summarize recent progresses in the Pharmacogenetics studies related to Stevens-Johnson syndrome/toxic epidermal necrolysis reporting the major genetic factors identified in the last years as associated with the disease and highlighting the use of some of these genomic variants in the clinical practice.

  17. Noise Reduction Techniques

    Science.gov (United States)

    Hallas, Tony

    There are two distinct kinds of noise - structural and color. Each requires a specific method of attack to minimize. The great challenge is to reduce the noise without reducing the faint and delicate detail in the image. My most-used and favorite noise suppression is found in Photoshop CS 5 Camera Raw. If I cannot get the desired results with the first choice, I will use Noise Ninja, which has certain advantages in some situations that we will cover.

  18. Johnson-McMillin microtia syndrome: New additional family

    Directory of Open Access Journals (Sweden)

    Nagwa Abdel-Meguid

    2014-01-01

    Full Text Available Microtia is a congenital anomaly that is found with different prevalence among various populations. The exact etiology of ear anomalies is still unknown. We describe a new additional family with this rare disorder; Johnson-McMillin syndrome (JMS where mother, son, and distant grandmother have multiple features of JMS in the form of microtia, facial asymmetry, ear malformation, hearing defect, and hypotrichosis. Variable presentations in this family could be referred to phenotype variation supporting an autosomal dominant pattern of inheritance. We observed that the mother was very sad and suffered from feelings of guilt. We found that she had isolated herself from family and community out of fear of being stigmatized and hurt. We concluded that the occurrence of microtia is of public health importance, adhering to traditional marriage customs in Egypt increases women′s risk of giving birth to a disabled child, yet the mothers are blamed and shamed for their children′s birth defects by their husbands, families, and communities, while the fathers are not stigmatized.

  19. Erythema multiforme and Stevens-Johnson syndrome following radiotherapy

    International Nuclear Information System (INIS)

    Yoshitake, Tadamasa; Nakamura, Katsumasa; Shioyama, Yoshiyuki

    2007-01-01

    Erythema multiforme (EM) and Stevens-Johnson syndrome (SJS) are thought to be hypersensitivity syndromes with various causes, and radiotherapy might be one of the causes of these syndromes. We herein report two cases of EM/SJS following radiotherapy. The first case was a 63-year-old woman with breast cancer. At the end of postoperative radiotherapy with 60 Gy, severe pruritic erythema appeared in the irradiated area and spread over the whole body. She was diagnosed with EM by a skin biopsy. The second case was a 77-year-old woman with uterine cervical cancer who underwent postoperative radiotherapy. At a dose of 30.6 Gy, pruritic redness appeared in the irradiated area and the precordial region, and it became widespread rapidly with polymorphic transformation. Although without any histological confirmation, SJS was strongly suspected because of her pruritic conjunctivitis. Because both patients were given medicines during irradiation, radiotherapy may not be the only cause of EM/SJS. However, it should be noted that radiotherapy might trigger EM/SJS. (author)

  20. Drone noise

    Science.gov (United States)

    Tinney, Charles; Sirohi, Jayant; University of Texas at Austin Team

    2017-11-01

    A basic understanding of the noise produced by single and multirotor drones operating at static thrust conditions is presented. This work acts as an extension to previous efforts conducted at The University of Texas at Austin (Tinney et al. 2017, AHS Forum 73). Propeller diameters ranging from 8 inch to 12 inch are examined for configurations comprising an isolated rotor, a quadcopter configuration and a hexacopter configuration, and with a constant drone pitch of 2.25. An azimuthal array of half-inch microphones, placed between 2 and 3 hub-center diameters from the drone center, are used to assess the acoustic near-field. Thrust levels, acquired using a six degree-of-freedom load cell, are then used to correlate acoustic noise levels to aerodynamic performance for each drone configuration. The findings reveal a nearly logarithmic increase in noise with increasing thrust. However, for the same thrust condition, considerable noise reduction is achieved by increasing the number of propeller blades thereby reducing the blade passage frequency and both the thickness and loading noise sources that accompany it.

  1. Overview of en route noise prediction using a integrated noise model

    Science.gov (United States)

    2010-04-20

    En route aircraft noise is often ignored in aircraft noise modeling because large amounts of noise attenuation due to long propagation distances between the aircraft and the receivers on the ground, reduced power in cruise flight compared to takeoff ...

  2. Noise-based Stego-ECC

    Directory of Open Access Journals (Sweden)

    Rahardjo Budi

    2014-03-01

    Full Text Available A novel method of inserting noise into stream of ciphered text is proposed. The goal of inserting noise is to increase the level of uncertainty, thus making it harder for an attacker to detect data and noise. This form of steganography is implemented using Elliptic Curve Cryptography (ECC. The process of embedding the noise to the message in the encryption process and removing the noise from the message in the decryption process is proposed in this work by modifying ElGamal to allow auto detection of data and noise.

  3. Johnson - Cook Strength Models for Mild and DP 590 Steels

    International Nuclear Information System (INIS)

    Vedantam, K.; Brar, N. S.; Bajaj, D.; Hill, S.

    2006-01-01

    Automotive steels, Mild and Dual Phase590 (DP590) are characterized in tension at room temperature, using the quasi-static and split Hopkinson bar techniques at various strain rates ranging from ∼10-3/s to ∼1800/s. Tension stress-strain data for both the steels are analyzed to determine the Johnson-Cook Strength model constants, J-C strength model constants for mild steel are A=217 MPa, B = 234 MPa, n = 0.643 and C = 0.076 and for DP590 steel are A = 430 MPa, B = 824 MPa, n = 0.510 and C = 0.017. Higher value of strain rate sensitivity constant C for mild steel (0.076) compared to DP 590 (0.017) is also reflected in the stress- strain data at various strain rates

  4. Bjorken-Johnson-Low technique and perturbation study on chiral anomaly in abelian coset pure gauge field theory

    International Nuclear Information System (INIS)

    Jing Sicong; Ruan Jie; AH. Dept. of Modern Physics)

    1990-01-01

    The perturbation theory in coset pure gauge field theory is studied for the first time. By using the Bjorken-johnson-Low technique and calculating the Schwinger term in related commutators, the anomalous Ward identity in Abelian coset pure gauge field theory is derived, which is consistent with the non-perutrbative calculation

  5. The Traffic Noise Index: A Method of Controlling Noise Nuisance.

    Science.gov (United States)

    Langdon, F. J.; Scholes, W. E.

    This building research survey is an analysis of the social nuisance caused by urban motor ways and their noise. The Traffic Noise Index is used to indicate traffic noises and their effects on architectural designs and planning, while suggesting the need for more and better window insulation and acoustical barriers. Overall concern is for--(1)…

  6. Practical acoustic thermometry with twin-tube and single-tube sensors

    Energy Technology Data Exchange (ETDEWEB)

    De Podesta, M.; Sutton, G.; Edwards, G.; Stanger, L.; Preece, H. [National Physical Laboratory, Teddington, (United Kingdom)

    2015-07-01

    Accurate measurement of high temperatures in a nuclear environment presents unique challenges. All secondary techniques inevitably drift because the thermometric materials in thermocouples and resistance sensors are sensitive not just to temperature, but also their own chemical and physical composition. The solution is to use primary methods that rely on fundamental links between measurable physical properties and temperature. In the nuclear field the best known technique is the measurement of Johnson Noise in a resistor (See Paper 80 at this conference). In this paper we describe the measurement of temperature in terms of the speed of sound in a gas confined in a tube - an acoustic waveguide. Acoustic thermometry is the most accurate technique of primary thermometry ever devised with the best uncertainty of measurement below 0.001 C. In contrast, the acoustic technique described in this work has a much larger uncertainty, approximately 1 deg. C. But the cost and ease of use are improved by several orders of magnitude, making implementation eminently practical. We first describe the basic construction and method of operation of thermometers using twin-tubes and single tubes. We then present results using a twin-tube design showing that showing long term stability (i.e. no detectable drift) at 700 deg. C over periods of several weeks. We then outline how the technique may be developed for different nuclear applications. (authors)

  7. Investigation of Diesel’s Residual Noise on Predictive Vehicles Noise Cancelling using LMS Adaptive Algorithm

    Science.gov (United States)

    Arttini Dwi Prasetyowati, Sri; Susanto, Adhi; Widihastuti, Ida

    2017-04-01

    Every noise problems require different solution. In this research, the noise that must be cancelled comes from roadway. Least Mean Square (LMS) adaptive is one of the algorithm that can be used to cancel that noise. Residual noise always appears and could not be erased completely. This research aims to know the characteristic of residual noise from vehicle’s noise and analysis so that it is no longer appearing as a problem. LMS algorithm was used to predict the vehicle’s noise and minimize the error. The distribution of the residual noise could be observed to determine the specificity of the residual noise. The statistic of the residual noise close to normal distribution with = 0,0435, = 1,13 and the autocorrelation of the residual noise forming impulse. As a conclusion the residual noise is insignificant.

  8. Noise Pollution

    Science.gov (United States)

    ... Regulated by EPA EPA or a designated Federal agency regulates noise sources, such as rail and motor carriers, low noise emission products, construction equipment, transport equipment, trucks, motorcycles, and the labeling of hearing ...

  9. Microcalorimetry and the transition-edge sensor

    Science.gov (United States)

    Lindeman, Mark Anton

    2000-10-01

    Many scientific and industrial applications call for quantum-efficient high-energy-resolution microcalorimeters for the measurement of x rays. The applications driving the development of these detectors involve the measurement of faint sources of x rays in which few photons reach the detector. Interesting astrophysical applications for these microcalorimeters include the measurement of composition and temperatures of stellar atmospheres and diffuse interstellar plasmas. Other applications of microcalorimeter technology include x-ray fluorescence (XRF) measurements of industrial or scientific samples. We are attempting to develop microcalorimeters with energy resolutions of several eV because many sources (such as celestial plasmas) contain combinations of elements producing emission lines spaced only a few eV apart. Our microcalorimeters consist of a metal-film absorber (250mum x 250mum x 3mum of copper) coupled to a superconducting transition-edge-sensor (TES) thermometer. This microcalorimeter demonstrated an energy resolution of 42 eV (FWHM) at 6 keV, excellent linearity, and showed no evidence of position dependent response. The response of our microcalorimeters depends both on the temperature of the microcalorimeter and on the electrical current conducted through the TES thermometer. We present a microcalorimeter model that extends previous microcalorimeter theory to include additional current dependent effects. The model makes predictions about the effects of various forms of noise. In addition, the model helps us to understand what measurements are useful for characterizing TES microcalorimeters. While the energy resolution we obtained was quite good (twice as good as conventional semiconductor-based x-ray detectors), the obtained resolution was not as good as expected, due to excess noise from fluctuations in the TES thermometer. The energy resolution of future TES microcalorimeters can be improved by redesigning the calorimeters to minimize the noise due

  10. Microcalorimetry and the transition-edge sensor

    International Nuclear Information System (INIS)

    Lindeman, M A

    2000-01-01

    Many scientific and industrial applications call for quantum-efficient high-energy-resolution microcalorimeters for the measurement of x rays. The applications driving the development of these detectors involve the measurement of faint sources of x rays in which few photons reach the detector. Interesting astrophysical applications for these microcalorimeters include the measurement of composition and temperatures of stellar atmospheres and diffuse interstellar plasmas. Other applications of microcalorimeter technology include x-ray fluorescence (XRF) measurements of industrial or scientific samples. We are attempting to develop microcalorimeters with energy resolutions of several eV because many sources (such as celestial plasmas) contain combinations of elements producing emission lines spaced only a few eV apart. Our microcalorimeters consist of a metal-film absorber (250 (micro)m x 250(micro)m x 3 (micro)m of copper) coupled to a superconducting transition-edge-sensor (TES) thermometer. This microcalorimeter demonstrated an energy resolution of 42 eV (FWHM) at 6 keV, excellent linearity, and showed no evidence of position dependent response. The response of our microcalorimeters depends both on the temperature of the microcalorimeter and on the electrical current conducted through the TES thermometer. We present a microcalorimeter model that extends previous microcalorimeter theory to include additional current dependent effects. The model makes predictions about the effects of various forms of noise. In addition, the model helps us to understand what measurements are useful for characterizing TES microcalorimeters. While the energy resolution we obtained was quite good (twice as good as conventional semiconductor-based x-ray detectors), the obtained resolution was not as good as expected, due to excess noise from fluctuations in the TES thermometer. The energy resolution of future TES microcalorimeters can be improved by redesigning the calorimeters to

  11. High internal noise and poor external noise filtering characterize perception in autism spectrum disorder.

    Science.gov (United States)

    Park, Woon Ju; Schauder, Kimberly B; Zhang, Ruyuan; Bennetto, Loisa; Tadin, Duje

    2017-12-14

    An emerging hypothesis postulates that internal noise is a key factor influencing perceptual abilities in autism spectrum disorder (ASD). Given fundamental and inescapable effects of noise on nearly all aspects of neural processing, this could be a critical abnormality with broad implications for perception, behavior, and cognition. However, this proposal has been challenged by both theoretical and empirical studies. A crucial question is whether and how internal noise limits perception in ASD, independently from other sources of perceptual inefficiency, such as the ability to filter out external noise. Here, we separately estimated internal noise and external noise filtering in ASD. In children and adolescents with and without ASD, we computationally modeled individuals' visual orientation discrimination in the presence of varying levels of external noise. The results revealed increased internal noise and worse external noise filtering in individuals with ASD. For both factors, we also observed high inter-individual variability in ASD, with only the internal noise estimates significantly correlating with severity of ASD symptoms. We provide evidence for reduced perceptual efficiency in ASD that is due to both increased internal noise and worse external noise filtering, while highlighting internal noise as a possible contributing factor to variability in ASD symptoms.

  12. Electronic structure engineering of ZnO with the modified Becke-Johnson exchange versus the classical correlation potential approaches

    KAUST Repository

    Ul Haq, Bakhtiar; Ahmed, Rashid; Goumri-Said, Souraya; Shaari, Amiruddin; Afaq, Ahmad

    2013-01-01

    applied. Where for electronic properties in addition to these, Tran-Blaha modified Becke-Johnson (mBJ) potential has been used. Our computed band gap values of ZnO in WZ and ZB phases with mBJ potential are significantly improved compared to those with LDA

  13. Wideband Low Noise Amplifiers Exploiting Thermal Noise Cancellation

    NARCIS (Netherlands)

    Bruccoleri, F.; Klumperink, Eric A.M.; Nauta, Bram

    2005-01-01

    Low Noise Amplifiers (LNAs) are commonly used to amplify signals that are too weak for direct processing for example in radio or cable receivers. Traditionally, low noise amplifiers are implemented via tuned amplifiers, exploiting inductors and capacitors in resonating LC-circuits. This can render

  14. Theory and Measurement of Signal-to-Noise Ratio in Continuous-Wave Noise Radar.

    Science.gov (United States)

    Stec, Bronisław; Susek, Waldemar

    2018-05-06

    Determination of the signal power-to-noise power ratio on the input and output of reception systems is essential to the estimation of their quality and signal reception capability. This issue is especially important in the case when both signal and noise have the same characteristic as Gaussian white noise. This article considers the problem of how a signal-to-noise ratio is changed as a result of signal processing in the correlation receiver of a noise radar in order to determine the ability to detect weak features in the presence of strong clutter-type interference. These studies concern both theoretical analysis and practical measurements of a noise radar with a digital correlation receiver for 9.2 GHz bandwidth. Firstly, signals participating individually in the correlation process are defined and the terms signal and interference are ascribed to them. Further studies show that it is possible to distinguish a signal and a noise on the input and output of a correlation receiver, respectively, when all the considered noises are in the form of white noise. Considering the above, a measurement system is designed in which it is possible to represent the actual conditions of noise radar operation and power measurement of a useful noise signal and interference noise signals—in particular the power of an internal leakage signal between a transmitter and a receiver of the noise radar. The proposed measurement stands and the obtained results show that it is possible to optimize with the use of the equipment and not with the complex processing of a noise signal. The radar parameters depend on its prospective application, such as short- and medium-range radar, ground-penetrating radar, and through-the-wall detection radar.

  15. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  16. Forest inventory, Peter T. Johnson Wildlife Mitigation Unit, Craig Mountain, Idaho. Final report

    International Nuclear Information System (INIS)

    Narolski, S.W.

    1996-12-01

    The primary objective of this report is to determine the quantity and quality of existing forest habitat types on the 59,991-acre Peter T. Johnson Wildlife Mitigation Unit (WMU). Products from this effort include a description of the ecological condition, a map of habitat types, and an inventory of forest resources on the WMU lands. The purpose of this and other resource inventories (plant and wildlife) is to assess the current resources condition of the WMU and to provide necessary information to generate a long-term management for this area

  17. Peristaltic flow of Johnson-Segalman fluid in asymmetric channel with convective boundary conditions

    Institute of Scientific and Technical Information of China (English)

    H YASMIN; T HAYAT; A ALSAEDI; HH ALSULAMI

    2014-01-01

    This work is concerned with the peristaltic transport of the Johnson-Segalman fluid in an asymmetric channel with convective boundary conditions. The mathematical modeling is based upon the conservation laws of mass, linear momentum, and energy. The resulting equations are solved after long wavelength and low Reynolds number are used. The results for the axial pressure gradient, velocity, and temperature profiles are obtained for small Weissenberg number. The expressions of the pressure gra-dient, velocity, and temperature are analyzed for various embedded parameters. Pumping and trapping phenomena are also explored.

  18. Forest inventory: Peter T. Johnson Wildlife Mitigation Unit, Craig Mountain, Idaho. Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    Narolski, Steven W.

    1996-12-01

    The primary objective of this report is to determine the quantity and quality of existing forest habitat types on the 59,991-acre Peter T. Johnson Wildlife Mitigation Unit (WMU). Products from this effort include a description of the ecological condition, a map of habitat types, and an inventory of forest resources on the WMU lands. The purpose of this and other resource inventories (plant and wildlife) is to assess the current resources condition of the WMU and to provide necessary information to generate a long-term management for this area.

  19. Design of a temperature measurement and feedback control system based on an improved magnetic nanoparticle thermometer

    Science.gov (United States)

    Du, Zhongzhou; Sun, Yi; Liu, Jie; Su, Rijian; Yang, Ming; Li, Nana; Gan, Yong; Ye, Na

    2018-04-01

    Magnetic fluid hyperthermia, as a novel cancer treatment, requires precise temperature control at 315 K-319 K (42 °C-46 °C). However, the traditional temperature measurement method cannot obtain the real-time temperature in vivo, resulting in a lack of temperature feedback during the heating process. In this study, the feasibility of temperature measurement and feedback control using magnetic nanoparticles is proposed and demonstrated. This technique could be applied in hyperthermia. Specifically, the triangular-wave temperature measurement method is improved by reconstructing the original magnetization response of magnetic nanoparticles based on a digital phase-sensitive detection algorithm. The standard deviation of the temperature in the magnetic nanoparticle thermometer is about 0.1256 K. In experiments, the temperature fluctuation of the temperature measurement and feedback control system using magnetic nanoparticles is less than 0.5 K at the expected temperature of 315 K. This shows the feasibility of the temperature measurement method for temperature control. The method provides a new solution for temperature measurement and feedback control in hyperthermia.

  20. Active noise cancellation of low frequency noise propagating in a duct

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2012-01-01

    Conclusions: With regard to the wide range of frequencies of different noise sources, having optimized circumstances in the duct, microphone location on the duct body or even the distance of the speakers may be important in signal processing, noise sampling and anti noise production.

  1. Noise sensitivity, rather than noise level, predicts the non-auditory effects of noise in community samples: a population-based survey

    Directory of Open Access Journals (Sweden)

    Jangho Park

    2017-04-01

    Full Text Available Abstract Background Excessive noise affects human health and interferes with daily activities. Although environmental noise may not directly cause mental illness, it may accelerate and intensify the development of latent mental disorders. Noise sensitivity (NS is considered a moderator of non-auditory noise effects. In the present study, we aimed to assess whether NS is associated with non-auditory effects. Methods We recruited a community sample of 1836 residents residing in Ulsan and Seoul, South Korea. From July to November 2015, participants were interviewed regarding their demographic characteristics, socioeconomic status, medical history, and NS. The non-auditory effects of noise were assessed using the Center of Epidemiologic Studies Depression, Insomnia Severity index, State Trait Anxiety Inventory state subscale, and Stress Response Inventory-Modified Form. Individual noise levels were recorded from noise maps. A three-model multivariate logistic regression analysis was performed to identify factors that might affect psychiatric illnesses. Results Participants ranged in age from 19 to 91 years (mean: 47.0 ± 16.1 years, and 37.9% (n = 696 were male. Participants with high NS were more likely to have been diagnosed with diabetes and hyperlipidemia and to use psychiatric medication. The multivariable analysis indicated that even after adjusting for noise-related variables, sociodemographic factors, medical illness, and duration of residence, subjects in the high NS group were more than 2 times more likely to experience depression and insomnia and 1.9 times more likely to have anxiety, compared with those in the low NS group. Noise exposure level was not identified as an explanatory value. Conclusions NS increases the susceptibility and hence moderates there actions of individuals to noise. NS, rather than noise itself, is associated with an elevated susceptibility to non-auditory effects.

  2. Noise, buildings and people

    Energy Technology Data Exchange (ETDEWEB)

    Croome, D J

    1977-01-01

    This book covers the physics of acoustics necessary to understand the analytical aspects of acoustical design and noise control in buildings. The major part is devoted to the problems of noise and man, and other chapters cover features of noise control in and around buildings. In an introduction, building environmental engineering is dealth with in general terms of architecture, creativity, systms design, etc. Aspects of the acoustical environment, noise sources in buildings, control of airborne and structure-borne noise and acoustical design techniques are covered in Part II. Items include: comfort, physiological response to noise and vibrations, noise criteria, human performance, speech communication, landscaped offices, sound generation by air-conditioning and heating equipment, building structure and noise attenuation, acoustical design. Part III gives some fundamentals of acoustics; mechanical vibration, wave motion, propagation of sound, structure-borne sound, behavior of sound in rooms, transmission of sound through structure. References include lists of British standards and booklets on health and safety at work.

  3. Investigations of internal noise levels for different target sizes, contrasts, and noise structures

    Science.gov (United States)

    Han, Minah; Choi, Shinkook; Baek, Jongduk

    2014-03-01

    To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.

  4. Noise from wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Fegeant, Olivier [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Building Sciences

    2002-02-01

    A rapid growth of installed wind power capacity is expected in the next few years. However, the siting of wind turbines on a large scale raises concerns about their environmental impact, notably with respect to noise. To this end, variable speed wind turbines offer a promising solution for applications in densely populated areas like the European countries, as this design would enable an efficient utilisation of the masking effect due to ambient noise. In rural and recreational areas where wind turbines are sited, the ambient noise originates from the action of wind on the vegetation and about the listener's ear (pseudo-noise). It shows a wind speed dependence similar to that of the noise from a variable speed wind turbine and can therefore mask the latter for a wide range of conditions. However, a problem inherent to the design of these machines is their proclivity to pure tone generation, because of the enhanced difficulty of avoiding structural resonances in the mechanical parts. Pure tones are deemed highly annoying and are severely regulated by most noise policies. In relation to this problem, the vibration transmission of structure-borne sound to the tower of the turbine is investigated, in particular when the tower is stiffened at its upper end. Furthermore, since noise annoyance due to wind turbine is mostly a masking issue, the wind-related sources of ambient noise are studied and their masking potentials assessed. With this aim, prediction models for wind-induced vegetation noise and pseudo-noise have been developed. Finally, closely related to the effect of masking, is the difficulty, regularly encountered by local authorities and wind farm developers, to measure noise immission from wind turbines. A new measurement technique has thus been developed in the course of this work. Through improving the signal-to-noise ratio between wind turbine noise and ambient noise, the new technique yields more accurate measurement results.

  5. A statistical background noise correction sensitive to the steadiness of background noise.

    Science.gov (United States)

    Oppenheimer, Charles H

    2016-10-01

    A statistical background noise correction is developed for removing background noise contributions from measured source levels, producing a background noise-corrected source level. Like the standard background noise corrections of ISO 3741, ISO 3744, ISO 3745, and ISO 11201, the statistical background correction increases as the background level approaches the measured source level, decreasing the background noise-corrected source level. Unlike the standard corrections, the statistical background correction increases with steadiness of the background and is excluded from use when background fluctuation could be responsible for measured differences between the source and background noise levels. The statistical background noise correction has several advantages over the standard correction: (1) enveloping the true source with known confidence, (2) assuring physical source descriptions when measuring sources in fluctuating backgrounds, (3) reducing background corrected source descriptions by 1 to 8 dB for sources in steady backgrounds, and (4) providing a means to replace standardized background correction caps that incentivize against high precision grade methods.

  6. Active3 noise reduction

    International Nuclear Information System (INIS)

    Holzfuss, J.

    1996-01-01

    Noise reduction is a problem being encountered in a variety of applications, such as environmental noise cancellation, signal recovery and separation. Passive noise reduction is done with the help of absorbers. Active noise reduction includes the transmission of phase inverted signals for the cancellation. This paper is about a threefold active approach to noise reduction. It includes the separation of a combined source, which consists of both a noise and a signal part. With the help of interaction with the source by scanning it and recording its response, modeling as a nonlinear dynamical system is achieved. The analysis includes phase space analysis and global radial basis functions as tools for the prediction used in a subsequent cancellation procedure. Examples are given which include noise reduction of speech. copyright 1996 American Institute of Physics

  7. 75 FR 39820 - Procedures for Abatement of Highway Traffic Noise and Construction Noise

    Science.gov (United States)

    2010-07-13

    ...-2008-0114] RIN 2125-AF26 Procedures for Abatement of Highway Traffic Noise and Construction Noise... the Federal regulations on the Procedures for Abatement of Highway Traffic Noise and Construction Noise. The final rule clarifies and adds definitions, the applicability of this regulation, certain...

  8. Institutionalism and culture in strategies of multinational firms: the case of Johnson controls Inc.

    Directory of Open Access Journals (Sweden)

    José G. Vargas-Hernández

    2013-07-01

    Full Text Available The aim of this paper is to analyze both the internal and external aspects that may pose a risk to the operations of the subsidiaries of the multinational Johnson Controls Inc. in the U.S. and Mexico from an institutional point of view. The main challenges are the impact in the achievement of goals both of workers and of the same organization and the influence institutions have on the organizational environment, for the decommissioning of some branch/ subsidiary.

  9. Noise Enhanced Stability

    International Nuclear Information System (INIS)

    Spagnolo, B.; Agudov, N.V.; Dubkov, A.A.

    2004-01-01

    The noise can stabilize a fluctuating or a periodically driven metastable state in such a way that the system remains in this state for a longer time than in the absence of white noise. This is the noise enhanced stability phenomenon, observed experimentally and numerically in different physical systems. After shortly reviewing all the physical systems where the phenomenon was observed, the theoretical approaches used to explain the effect are presented. Specifically the conditions to observe the effect in systems: (a) with periodical driving force, and (b) with random dichotomous driving force, are discussed. In case (b) we review the analytical results concerning the mean first passage time and the nonlinear relaxation time as a function of the white noise intensity, the parameters of the potential barrier, and of the dichotomous noise. (author)

  10. Approximations to camera sensor noise

    Science.gov (United States)

    Jin, Xiaodan; Hirakawa, Keigo

    2013-02-01

    Noise is present in all image sensor data. Poisson distribution is said to model the stochastic nature of the photon arrival process, while it is common to approximate readout/thermal noise by additive white Gaussian noise (AWGN). Other sources of signal-dependent noise such as Fano and quantization also contribute to the overall noise profile. Question remains, however, about how best to model the combined sensor noise. Though additive Gaussian noise with signal-dependent noise variance (SD-AWGN) and Poisson corruption are two widely used models to approximate the actual sensor noise distribution, the justification given to these types of models are based on limited evidence. The goal of this paper is to provide a more comprehensive characterization of random noise. We concluded by presenting concrete evidence that Poisson model is a better approximation to real camera model than SD-AWGN. We suggest further modification to Poisson that may improve the noise model.

  11. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  12. Power reactor noise

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    This book concentrates on the different types of noise present in power reactors and how the analysis of this noise can be used as a tool for reactor monitoring and diagnostics. Noise analysis is a growing field that offers advantages such as simplicity, low cost, and natural multivariable interactions. A major advantage, continuous and undisturbed monitoring, supplies a means of obtaining early warnings of possible reactor malfunctions thus preventing further complications by alerting operators to a problem - and aiding in the diagnosis of that problem - before it demands major repairs. Following an introductory chapter, the theoretical basis for the various methods of noise analysis is explained, and full chapters are devoted to the fundamentals of statistics for time-domain analysis and Fourier series and related topics for frequency-domain analysis. General experimental techniques and associated theoretical considerations are reviewed, leading to discussion of practical applications in the latter half of the book. Besides chapters giving examples of neutron noise and acoustical noise, chapters are also devoted to extensive examples from pressurized water reactor and boiling water reactor power plants

  13. Noise in the operating room

    DEFF Research Database (Denmark)

    Hasfeldt-Hansen, Dorthe; Lærkner, Eva Ann; Birkelund, Regner

    2010-01-01

    Because noise is a general stressor, noise in the OR should be avoided whenever possible. This article presents the results of a review of the research literature on the topic of noise in the OR. A systematic literature search was conducted. Eighteen relevant articles were identified...... and categorized as follows: noise levels, noise sources, staff performances, and patient’s perception of noise. Each study was assessed according to the strength of the evidence and the quality of the study. Noise levels in the OR in general exceed recommended levels, and the noise sources are related...... to equipment and staff behavior. The main effect of noise on staff performances is related to impaired communication, resulting in a negative effect on patient safety. The literature on patients’ perception of noise is both limited and inconsistent, and more research on this topic is needed....

  14. Examining nocturnal railway noise and aircraft noise in the field: sleep, psychomotor performance, and annoyance.

    Science.gov (United States)

    Elmenhorst, Eva-Maria; Pennig, Sibylle; Rolny, Vinzent; Quehl, Julia; Mueller, Uwe; Maaß, Hartmut; Basner, Mathias

    2012-05-01

    Traffic noise is interfering during day- and nighttime causing distress and adverse physiological reactions in large parts of the population. Railway noise proved less annoying than aircraft noise in surveys which were the bases for a so called 5 dB railway bonus regarding noise protection in many European countries. The present field study investigated railway noise-induced awakenings during sleep, nighttime annoyance and the impact on performance the following day. Comparing these results with those from a field study on aircraft noise allowed for a ranking of traffic modes concerning physiological and psychological reactions. 33 participants (mean age 36.2 years ± 10.3 (SD); 22 females) living alongside railway tracks around Cologne/Bonn (Germany) were polysomnographically investigated. These data were pooled with data from a field study on aircraft noise (61 subjects) directly comparing the effects of railway and aircraft noise in one random subject effects logistic regression model. Annoyance was rated in the morning evaluating the previous night. Probability of sleep stage changes to wake/S1 from railway noise increased significantly from 6.5% at 35 dB(A) to 20.5% at 80 dB(A) LAFmax. Rise time of noise events had a significant impact on awakening probability. Nocturnal railway noise led to significantly higher awakening probabilities than aircraft noise, partly explained by the different rise times, whereas the order was inversed for annoyance. Freight train noise compared to passenger train noise proved to have the most impact on awakening probability. Nocturnal railway noise had no effect on psychomotor vigilance. Nocturnal freight train noise exposure in Germany was associated with increased awakening probabilities exceeding those for aircraft noise and contrasting the findings of many annoyance surveys and annoyance ratings of our study. During nighttime a bonus for railway noise seems not appropriate. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. CALIBRATING THE JOHNSON-HOLMQUIST CERAMIC MODEL FOR SIC USING CTH

    International Nuclear Information System (INIS)

    Cazamias, J. U.; Bilyk, S. R.

    2009-01-01

    The Johnson-Holmquist ceramic material model has been calibrated and successfully applied to numerically simulate ballistic events using the Lagrangian code EPIC. While the majority of the constants are ''physics'' based, two of the constants for the failed material response are calibrated using ballistic experiments conducted on a confined cylindrical ceramic target. The maximum strength of the failed ceramic is calibrated by matching the penetration velocity. The second refers to the equivalent plastic strain at failure under constant pressure and is calibrated using the dwell time. Use of these two constants in the CTH Eulerian hydrocode does not predict the ballistic response. This difference may be due to the phenomenological nature of the model and the different numerical schemes used by the codes. This paper determines the aforementioned material constants for SiC suitable for simulating ballistic events using CTH.

  16. Stevens-Johnson syndrome in patients on phenytoin and cranial radiotherapy

    International Nuclear Information System (INIS)

    Khafaga, Y.M.; Jamshed, A.; Allam, A.A.K.; Ezzat, A.; Gray, A.J.; Schultz, H.; Mourad, W.A.; Al Eisa, A.

    1999-01-01

    The use of phenytoin as a prophylactic anticonvulsant after brain surgery, particularly for brain tumors, is a common practice, regardless of whether the patient has a previous history of convulsions. This treatment policy assumes that the benefits exceed the risks. Four cases are described of adverse reactions of phenytoin during the cocomitant use of cranial radiotherapy. In one patient this proved fatal. There is increasing anecdotal support in the literature for a synergistic effect between phenytoin therapy and cranial radiotherapy that can result in the life-threatening Stevens-Johnson syndrome. While the association is uncommon, four cases within 24 months in one department suggest that the routine use of postoperative phenytoin as a prophylactic anticonvulsant in the absence of a history of seizures may not be warranted, particularly if the patient is to receive cranial radiotherapy. (orig.)

  17. Spin noise amplification and giant noise in optical microcavity

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhov, I. I.; Poltavtsev, S. V.; Kozlov, G. G.; Zapasskii, V. S. [Spin-Optics Laboratory, St. Petersburg State University, 198504 St. Petersburg (Russian Federation); Kavokin, A. V. [Department of Physics and Astronomy, University of Southampton, Southampton SO17 1BJ (United Kingdom); Spin-Optics Laboratory, St. Petersburg State University, 198504 St. Petersburg (Russian Federation); Lagoudakis, P. V. [Department of Physics and Astronomy, University of Southampton, Southampton SO17 1BJ (United Kingdom)

    2015-06-14

    When studying the spin-noise-induced fluctuations of Kerr rotation in a quantum-well microcavity, we have found a dramatic increase of the noise signal (by more than two orders of magnitude) in the vicinity of anti-crossing of the polariton branches. The effect is explained by nonlinear optical instability of the microcavity giving rise to the light-power-controlled amplification of the polarization noise signal. In the framework of the developed model of built-in amplifier, we also interpret the nontrivial spectral and intensity-related properties of the observed noise signal below the region of anti-crossing of polariton branches. The discovered effect of optically controllable amplification of broadband polarization signals in microcavities in the regime of optical instability may be of interest for detecting weak oscillations of optical anisotropy in fundamental research and for other applications in optical information processing.

  18. Data Mining FAERS to Analyze Molecular Targets of Drugs Highly Associated with Stevens-Johnson Syndrome

    OpenAIRE

    Burkhart, Keith K.; Abernethy, Darrell; Jackson, David

    2015-01-01

    Drug features that are associated with Stevens-Johnson syndrome (SJS) have not been fully characterized. A molecular target analysis of the drugs associated with SJS in the FDA Adverse Event Reporting System (FAERS) may contribute to mechanistic insights into SJS pathophysiology. The publicly available version of FAERS was analyzed to identify disproportionality among the molecular targets, metabolizing enzymes, and transporters for drugs associated with SJS. The FAERS in-house version was al...

  19. Noise Scaling and Community Noise Metrics for the Hybrid Wing Body Aircraft

    Science.gov (United States)

    Burley, Casey L.; Brooks, Thomas F.; Hutcheson, Florence V.; Doty, Michael J.; Lopes, Leonard V.; Nickol, Craig L.; Vicroy, Dan D.; Pope, D. Stuart

    2014-01-01

    An aircraft system noise assessment was performed for the hybrid wing body aircraft concept, known as the N2A-EXTE. This assessment is a result of an effort by NASA to explore a realistic HWB design that has the potential to substantially reduce noise and fuel burn. Under contract to NASA, Boeing designed the aircraft using practical aircraft design princip0les with incorporation of noise technologies projected to be available in the 2020 timeframe. NASA tested 5.8% scale-mode of the design in the NASA Langley 14- by 22-Foot Subsonic Tunnel to provide source noise directivity and installation effects for aircraft engine and airframe configurations. Analysis permitted direct scaling of the model-scale jet, airframe, and engine shielding effect measurements to full-scale. Use of these in combination with ANOPP predictions enabled computations of the cumulative (CUM) noise margins relative to FAA Stage 4 limits. The CUM margins were computed for a baseline N2A-EXTE configuration and for configurations with added noise reduction strategies. The strategies include reduced approach speed, over-the-rotor line and soft-vane fan technologies, vertical tail placement and orientation, and modified landing gear designs with fairings. Combining the inherent HWB engine shielding by the airframe with added noise technologies, the cumulative noise was assessed at 38.7 dB below FAA Stage 4 certification level, just 3.3 dB short of the NASA N+2 goal of 42 dB. This new result shows that the NASA N+2 goal is approachable and that significant reduction in overall aircraft noise is possible through configurations with noise reduction technologies and operational changes.

  20. On the prediction of impact noise, V: The noise from drop hammers

    Science.gov (United States)

    Richards, E. J.; Carr, I.; Westcott, M.

    1983-06-01

    In earlier papers in this series, the concepts of "acceleration" and "ringing" noise have been studied in relation to impact machines, and values of radiation efficiency have been obtained for the various types of structural components. In the work reported in this paper the predicted and measured noise radiation from a drop hammer, both in full-scale and in {1}/{3}- scale model form, were examined. It is found that overall noise levels ( Leq per event) can be predicted from vibration measurements to within ± 1·5 dB, and to within ±2·5 dB in one-third octave bands. In turn this has permitted noise reduction techniques to be examined by studies of local component vibration levels rather than overall noise, a method which provides considerable enlightenment at the design stage. It is shown that on one particular drop hammer, the noise energy is shared surprisingly uniformly over four or five sources, and that when these have been reduced, the overall noise reduction is severely limited by the "acceleration" noise from the "tup" or "hammer" itself. As this is difficult to eliminate without a basic change in forging technology, it follows that "tup" enclosure or modification of the sharpness of the final "hard" impact are the only means available for any serious noise reduction. Also indicated is the reliability of using model techniques, suitably scaled in frequency and impulse magnitude, in developing machinery with impact characteristics.