WorldWideScience

Sample records for jendl dosimetry file

  1. JENDL Dosimetry File

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  2. JENDL Dosimetry File

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  3. JENDL dosimetry file 99 (JENDL/D-99)

    Kobayashi, Katsuhei; Iwasaki, Shin

    2002-01-01

    The JENDL Dosimetry File 99 (JENDL/D-99), which is a revised version of the JENDL Dosimetry File 91 (JENDL/D-91), has been compiled and released for the determination of neutron flux and energy spectra. This work was undertaken to remove the inconsistency between the cross sections and their covariances in JENDL/D-91 since the covariances were mainly taken from IRDF-85 although the cross sections were based on JENDL-3. Dosimetry cross sections have been evaluated for 67 reactions on 47 nuclides together with covariances. The cross sections for 34 major reactions and their covariances were simultaneously generated, and the remaining 33 reaction data were mainly taken from JENDL/D-91. Latest measurements were taken into account in the evaluation. The resultant evaluated data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-6 format. In order to confirm the reliability of the evaluated data, several integral tests have been carried out: comparisons with average cross sections measured in fission neutron fields, fast/thermal reactor spectra, DT neutron fields and Li(d,n) neutron fields. It was found from the comparisons that the cross sections calculated from JENDL/D-99 are generally in good agreement with the measured data. The contents of JENDL/D-99 and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form in the Appendix. (author)

  4. JENDL special purpose file

    Nakagawa, Tsuneo

    1995-01-01

    In JENDL-3,2, the data on all the reactions having significant cross section over the neutron energy from 0.01 meV to 20 MeV are given for 340 nuclides. The object range of application extends widely, such as the neutron engineering, shield and others of fast reactors, thermal neutron reactors and nuclear fusion reactors. This is a general purpose data file. On the contrary to this, the file in which only the data required for a specific application field are collected is called special purpose file. The file for dosimetry is a typical special purpose file. The Nuclear Data Center, Japan Atomic Energy Research Institute, is making ten kinds of JENDL special purpose files. The files, of which the working groups of Sigma Committee are in charge, are listed. As to the format of the files, ENDF format is used similarly to JENDL-3,2. Dosimetry file, activation cross section file, (α, n) reaction data file, fusion file, actinoid file, high energy data file, photonuclear data file, PKA/KERMA file, gas production cross section file and decay data file are described on their contents, the course of development and their verification. Dosimetry file and gas production cross section file have been completed already. As for the others, the expected time of completion is shown. When these files are completed, they are opened to the public. (K.I.)

  5. Integral test of JENDL dosimetry file using fast neutron field in the Experimental Fast Reactor JOYO

    Aoyama, Takafumi; Sekine, Takashi

    1999-09-01

    In order to evaluate the applicability of the JENDL dosimetry file, an integral test using a fast neutron spectrum field in the Experimental Fast Reactor JOYO Mark-II core was performed. The dosimeter set consisting of eight reactions of 46 Ti(n,p) 46 Sc, 54 Fe(n,p) 54 Mn, 58 Fe(n,γ) 59 Fe, 58 Ni(n,p) 58 Co, 59 Co(n,γ) 60 Co, 63 Cu(n,α) 60 Co, 238 U fission and 237 Np fission was irradiated for approximately 30 days near the core center of the JOYO Mk-II. Neutron flux at the dosimeter position was calculated using the two dimensional discrete ordinate transport code 'DORT'. The core configuration was modeled in XY geometry, and the 100 group cross section set of JSD-J2 / JFT-J2, which was processed from JENDL-2, was utilized. The absolute value of neutron flux was normalized so that the 235 U fission rate using the calculated neutron spectrum agreed with the measured reaction rate. The 103 group cross section data were processed by 'NJOY' code for nuclides to be used in the JOYO dosimetry. As the results of integral test for JENDL/D-99 (new file) and JENDL/D-91 (previous file), calculated values by JENDL/D-99 agreed well with the experimental values, and the C/E ratios ranged from 0.95 to 1.22. By comparing the results between JENDL/D-99 and JENDL/D-91, small differences exist, except for 58 Fe(n, γ) 59 Fe reaction, which was improved significantly in JENDL/D-99. (author)

  6. ZZ-FSXLIB-JD99, MCNP nuclear data library based on JENDL Dosimetry File 99

    Shibata, Keiichi

    2007-01-01

    Description: JENDL Dosimetry File 99 processed into ACE for Monte Carlo calculations. JENDL/D-99 based MCNP library. Format: ACE. Number of groups: Continuous energy cross section library. Nuclides: 47 Nuclides and 67 reactions: Li-6 (n, triton) alpha; Li-6 alpha-production; Li-7 triton- production; B-10 (n, alpha) Li-7; B-10 alpha-production; F-19 (n, 2n) F-18; Na-23 (n, 2n) Na-22; Na-23 (n, gamma) Na-24; Mg-24 (n, p) Na-24; Al-27 (n, p) Mg-27; Al-27 (n, alpha) Na-24; P-31 (n, p) Si-31; S-32 (n, p) P-32; Sc-45 (n, gamma) Sc-46; Ti-nat (n, x) Sc-46; Ti-nat (n, x) Sc-47; Ti-nat (n, x) Sc-48; Ti-46 (n, 2n) Ti-45; Ti-46 (n, p) Sc-46; Ti-47 (n, np) Sc-46; Ti-47 (n, p) Sc-47; Ti-48 (n, np) Sc-47; Ti-48 (n, p) Sc-48; Ti-49 (n, np) Sc-48; Cr-50 (n, gamma) Cr-51; Cr-52 (n, 2n) Cr-51; Mn-55 (n, 2n) Mn-54; Mn-55 (n, gamma) Mn-56; Fe-54 (n, p) Mn-54; Fe-56 (n, p) Mn-56; Fe-57 (n, np) Mn-56; Fe-58 (n, gamma) Fe-59; Co-59 (n, 2n) Co-58; Co-59 (n, gamma) Co-60; Co-59 (n, alpha) Mn-56; Ni-58 (n, 2n) Ni-57; Ni-58 (n, p) Co-58; Ni-60 (n, p) Co-60; Cu-63 (n, 2n) Cu-62; Cu-63 (n, gamma) Cu-64; Cu-63 (n, alpha) Co-60; Cu-65 (n, 2n) Cu-64; Zn-64 (n, p) Cu-64; Y-89 (n, 2n) Y-88; Zr-90 (n, 2n) Zr-89; Nb-93 (n, n') Nb-93m; Nb-93 (n, 2n) Nb-92m; Rh-103 (n, n') Rh-103m; Ag-109 (n, gamma) Ag-110m; In-115 (n, n') In-115m; In-115 (n, gamma) In-116m; I-127 (n,2n) I-126; Eu-151 (n, gamma) Eu-152; Tm-169 (n,2n) Tm-168; Ta-181 (n, gamma) Ta-182; W-186 (n, gamma) W-187; Au-197 (n, 2n) Au-196; Au-197 (n, gamma) Au-198; Hg-199 (n, n') Hg-199m; Th-232 - fission; Th-232 (n, gamma) Th-233; U-235 - fission; U-238 - fission; U-238 (n, gamma) U-239; Np-237 - fission; Pu-239 - fission; Am-241 - fission. The data were produced on the 31 of March, 2006

  7. JENDL gas-production cross section file

    Nakagawa, Tsuneo; Narita, Tsutomu

    1992-05-01

    The JENDL gas-production cross section file was compiled by taking cross-section data from JENDL-3 and by using the ENDF-5 format. The data were given to 23 nuclei or elements in light nuclei and structural materials. Graphs of the cross sections and brief description on their evaluation methods are given in this report. (author)

  8. Summary of JENDL-2 general purpose file

    Nakagawa, Tsuneo [ed.

    1984-06-15

    The general purpose file of the second version of Japanese Evaluated Nuclear Data Library (JENDL-2) was released in December 1982. Recently, descriptive data were added to JENDL-2 and at the same time the first revision of numerical data was performed. JENDL-2 (Rev.1) consists of the data for 89 nuclides and about 211,000 records in the ENDF/B-IV format. In this report, full listings of presently added descriptive data are given to summarize the JENDL-2 general purpose file. The 2200-m/sec and 14-MeV cross sections, resonance integrals, Maxwellian and fission spectrum averaged cross sections are given in a table. Average cross sections were also calculated in suitable energy intervals.

  9. Summary of JENDL-2 general purpose file

    Nakagawa, Tsuneo

    1984-06-01

    The general purpose file of the second version of Japanese Evaluated Nuclear Data Library (JENDL-2) was released in December 1982. Recently, descriptive data were added to JENDL-2 and at the same time the first revision of numerical data was performed. JENDL-2 (Rev1) consists of the data for 89 nuclides and about 211,000 records in the ENDF/B-IV format. In this report, full listings of presently added descriptive data are given to summarize the JENDL-2 general purpose file. The 2200-m/sec and 14-MeV cross sections, resonance integrals, Maxwellian and fission spectrum averaged cross sections are given in a table. Average cross sections were also calculated in suitable energy intervals. (author)

  10. Status and evaluation methods of JENDL fusion file and JENDL PKA/KERMA file

    Chiba, S.; Fukahori, T.; Shibata, K.; Yu Baosheng; Kosako, K.

    1997-01-01

    The status of evaluated nuclear data in the JENDL fusion file and PKA/KERMA file is presented. The JENDL fusion file was prepared in order to improve the quality of the JENDL-3.1 data especially on the double-differential cross sections (DDXs) of secondary neutrons and gamma-ray production cross sections, and to provide DDXs of secondary charged particles (p, d, t, 3 He and α-particle) for the calculation of PKA and KERMA factors. The JENDL fusion file contains evaluated data of 26 elements ranging from Li to Bi. The data in JENDL fusion file reproduce the measured data on neutron and charged-particle DDXs and also on gamma-ray production cross sections. Recoil spectra in PKA/KERMA file were calculated from secondary neutron and charged-particle DDXs contained in the fusion file with two-body reaction kinematics. The data in the JENDL fusion file and PKA/KERMA file were compiled in ENDF-6 format with an MF=6 option to store the DDX data. (orig.)

  11. The JENDL-3 Sublibrary for Dosimetry. Summary of contents

    Nakazawa, M.; Kobayashi, K.; Iwasaki, S.; Iguchi, T.; Sakurai, K.; Ikeda, Y.; Nakagawa, T.

    1992-01-01

    This document summarizes the contents of the JENDL-3 Sublibrary for Dosimetry. This nuclear data library contains neutron activation cross-sections for selected materials that are used for reactor neutron dosimetry by foil activation. The library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section upon request. (author)

  12. Status of the JENDL activation file

    Nakajima, Yutaka

    1996-01-01

    The preliminary JENDL activation file was accomplished in February 1995 and has been used in the Japanese Nuclear Data Committee and as one of the data sources for the Fusion Evaluated Nuclear Data Library in IAEA. Since there are already big activation libraries in western Europe and United States, we are aiming at more accurate evaluation of important reactions to application to nuclear energy development rather than aiming at as many reaction data as in these big libraries. In the preliminary file 1,158 reaction cross sections have been compiled for 225 nuclides up to 20 MeV. (author)

  13. Integral test of JENDL fusion file

    Maekawa, Fujio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    Integral test of JENDL Fusion File (J-FF) is performed through analyses of available benchmark experiments. As a result, good agreement between the calculated results with J-FF and the measured data is observed as a whole. Thus, J-FF is qualified to be used for nuclear design of fusion reactors. Owing to the high quality evaluation of J-FF, cross section data in J-FF for many nuclides are recommended to be assigned as data in FENDL/E-2.0 in the IAEA Consultants` Meeting held at Karlsruhe, Germany, 24-28 June, 1996. (author)

  14. JENDL special purpose data files and related nuclear data

    Iijima, Shungo

    1989-01-01

    The objectives of JENDL Special Purpose Data Files under development are the applications of nuclear data to the evaluation of the fuel cycle, nuclear activation, and radiation damage. The files in plan consist of 9 types of data, viz., the actinide cross sections, the decay data, the activation cross sections, the (α,n) cross sections, the photo-reaction cross sections, the dosimetry cross sections, the gas production cross sections, the primary knock-on atom spectra and KERMA factors, and the data for standard. The status of the compilation and the evaluation of these data are briefly reviewed. In particular, the features of the data required for the evaluation of the activation cross sections, (α,n) cross sections, photo-reaction cross sections, and PKA data are discussed in some detail. The need for the realistic definition of the scope of the work is emphasized. (author)

  15. Strategy on review method for JENDL High Energy File

    Yamano, Naoki [Sumitomo Atomic Energy Industries Ltd., Tokyo (Japan)

    1998-11-01

    Status on review method and problems for a High Energy File of Japanese Evaluated Nuclear Data Library (JENDL-HE File) has been described. Measurements on differential and integral data relevant to the review work for the JENDL-HE File have been examined from a viewpoint of data quality and applicability. In order to achieve the work effectively, strategy on development of standard review method has been discussed as well as necessity of tools to be used in the review scheme. (author)

  16. Photon and decay data libraries for ORIGEN2 code based on JENDL FP decay data file 2000

    Katakura, J I

    2002-01-01

    Photon and decay data libraries for the ORIGEN2 code have been updated by using JENDL FP Decay Data File 2000 (JENDL/FPD-00). As for the decay data, half-lives, branching ratios and recoverable energy values have been replaced with those of the JENDL/FPD-00 file. The data of the photon library has been also replaced with those of the JENDL/FPD-00 file in which photon data of the nuclides without measured data are calculated with a theoretical method. Using the updated photon library, the calculation of photon spectrum at a short time after fission event is able to be made.

  17. Status of JENDL High Energy File. Evaluation method, tools, specification, release procedure, etc

    Fukahori, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    The ENDF-6 format file should be kept as a standard distribution file and it is not difficult to convert into some other form for code`s libraries. From this point of view, status of JENDL High Energy File is introduced in this report as well as evaluation strategy, recommended specification, stored nuclides and quantities, a format structure, evaluation methods and tools, and release plan. (author)

  18. Continuous energy cross section library for MCNP/MCNPX based on JENDL high energy file 2007. FXJH7

    Sasa, Toshinobu; Sugawara, Takanori; Fukahori, Tokio; Kosako, Kazuaki

    2008-11-01

    The latest JENDL High Energy File (JENDL/HE) was released in 2007 to respond the requirements of reaction data in high energy range up to several GeV to design accelerator facilities such as accelerator-driven systems and research complex like J-PARC. To apply the JENDL/HE-2007 file to the design study, the cross section library of FXJH7 series was constructed from the JENDL/HE file for the calculation using MCNP and MCNPX codes which are widely used in the field of nuclear reactors, fusion reactors, accelerator facilities, medical applications, and so on. In this report, the outline of the JENDL/HE-2007 file, modification of nuclear data processing code NJOY99, construction of FXJH7 library and test calculations for shielding and eigenvalue analyses are summarized. (author)

  19. Status of the JENDL Project

    Shibata, Keiichi; Nakagawa, Tsuneo; Fukahori, Tokio; Ichihara, Akira; Iwamoto, Osamu; Otsuka, Naohiko; Katakura, Jun-ichi

    2005-01-01

    Activities on the general-purpose and special-purpose files of JENDL are described. Evaluation work for the general-purpose file JENDL-4 has started in order to provide users with high-quality data. Part of the JENDL High Energy File and the JENDL Photonuclear Data File were released this year. Nuclear model codes are developed so as to make evaluations efficiently. The nuclear data utilization system is being created to disseminate JENDL data

  20. Data Analysis of Minima Total Cross-sections of Nitrogen-14 on JENDL-3.2Nuclear Data File

    Suwoto; Pandiangan, Tumpal; Ferhat-Aziz

    2000-01-01

    The integral tests of neutron cross-section for shielding material suchas nitrogen-14 contained in JENDL-3.2 file have been performed. Analysis ofthe calculation for nitrogen-14 was based on the MAEKER's ORNL-BroomstickExperiment at ORNL-USA. For the data comparison, the calculation analysiswith JENDL-3.1 file, ENDF/B-IV file, ENDF/B-VI file and JEF2.2 have also beencarried out. The overall calculation results by using JENDL-3.2 evaluationshowed good agreement with the experimental data, as well as those with theENDF/B-VI evaluation. In particular, the JENDL-3.2 evaluation gave betterresults than JENDL-3.1 evaluation and ENDF/B-IV. It was been concluded thatthe total cross-sections of Nitrogen-14 contained in JENDL-3.2 file is invery good agreement with the experimental results, although the totalcross-section in the energy range between 0.5 MeV and 0.9 MeV on fileJENDL-3.2 was small (about 4% lower), and minima of total cross-sections wasdeeper. (author)

  1. JENDL FP decay data file 2000 and the beta-decay theory

    Yoshida, Tadashi; Katakura, Jun Ichi; Tachibana, Takahiro

    2002-01-01

    JENDL FP Decay Data File 2000 has been developed as one of the special purpose files of the Japanese Evaluated Nuclear Data Library (JENDL), which constitutes a versatile nuclear data basis for science and technology. In the format of ENDF-6 this file includes the decay data for 1087 unstable fission product (FP) nuclides and 142 stable nuclides as their daughters. The primary purpose of this file is to use in the summation calculation of FP decay heat, which plays a critical role in nuclear safety analysis; the loss-of-coolant accident analysis of reactors, for example. The data for a given nuclide are its decay modes, the Q value, the branching ratios, the average energies released in the form of beta- and gamma-rays per decay, and their spectral data. The primary source of the decay data adopted here is the ENSDF (Evaluated Nuclear Structure Data File). The data in ENSDF, however, cover only the measured values. The data of the short-lived nuclides, which are essential for the decay heat calculations at short cooling times, are often fully lacking or incomplete even if they exist. This is mainly because of their short half-life nature. For such nuclides a theoretical model calculation is applied in order to fill the gaps between the true and the experimentally known decay schemes. In practice we have to predict the average decay energies and the spectral data for a lot of short-lived FPs by use of beta-decay theories. Thus the beta-decay theory plays a very important role in generating the FP decay data file

  2. Recent advances in the JENDL project

    Shibata, K.; Nakagawa, T.; Fukahori, T.; Iwamoto, O.; Ichihara, A.; Iwamoto, N.; Kunieda, S.; Otuka, N.; Katakura, J.; Watanabe, Y.; Kosako, K.

    2008-01-01

    General- and special-purpose JENDL data files are being produced in cooperation with the Japanese Nuclear Data Committee. Nuclear model codes have been developed in order to raise the reliability of the fourth version of JENDL General-Purpose File (JENDL-4). Minor actinides and fission products data have been evaluated for JENDL-4. The capture cross section of 235 U was examined in the energy region from 2 keV to 1 MeV. As a follow-up action on the previous library JENDL-3.3, covariances of several nuclei were estimated for a study on accelerator driven systems. The evaluation for the 2007 versions of JENDL High Energy File (JENDL/HE) and JENDL Photonuclear Data File (JENDL/PD), which are regarded as special-purpose files, is in the final stage. Analyses of neutron transmission experiments reveal the reliability of JENDL/HE. (authors)

  3. Introduction [International Reactor Dosimetry File 2002 (IRDF-2002)

    Paviotti-Corcuera, R.; Zolnay, E.M.

    2006-01-01

    The most recently tested version of the International Reactor Dosimetry File, IRDF-90 Version 2 (IRDF-90.2), was released in 1993. Most of the evaluations used in this file were prepared in the mid-1980s, and in the meantime a large amount of new experimental data has become available, along with two new national reactor dosimetry libraries (the Russian Reactor Dosimetry File (RRDF-98) and the Japanese Evaluated Nuclear Data Library (JENDL/D-99)). The cross-sections and related uncertainties for several reactions in these libraries may be of better quality than the data in the older IRDF-90 file. These developments have resulted in different cross-section values being applied to the evaluation of experimental data, creating difficulties in comparing the results of reactor dosimetry calculations from the same types of nuclear facility. Therefore, there has been a strong demand from the reactor dosimetry community for an updated and standardized version of the IRDF. The IAEA has in the past supported similar efforts to improve the quality of data for reactor dosimetry applications. A major objective of the present data development project was to prepare and distribute a standardized, updated and tested reactor dosimetry cross-section library accompanied by uncertainty information (IRDF-2002) for use in service life assessments of nuclear power reactors. In order to achieve this objective, two technical meetings were organized. Both meetings were held at the IAEA in Vienna. The first meeting took place from 27 to 29 August 2002, the second from 1 to 3 October 2003. Recommendations were made concerning the following topics and the preparation of the library: reactions to be included, requirements for new evaluations or revisions, nuclear decay data, radiation damage data, testing of the data in benchmark fields and inclusion of computer codes. The participants emphasized that good quality nuclear data for reactor dosimetry are essential to improve assessments of the

  4. Japanese evaluated nuclear data library, version-3 - JENDL-3

    Kikuchi, Yasuyuki

    1992-01-01

    The third version of Japanese Evaluated Nuclear Data Library (JENDL-3) has been developed aiming at really general applications such as fission, fusion and shielding calculations. The general purpose file of JENDL-3 contains neutron nuclear data for 324 nuclides in the ENDF-5 format. In the JENDL-3 evaluation, much effort has been devoted to improve reliability of high-energy data for fusion application, which were not satisfactory in JENDL-2, and to include gamma-ray production data. Some advanced nuclear theoretical models were adopted and recent experimental data of energy-angle double-differential cross sections (DDX) mainly measured in Japan were taken into account. Various benchmark tests have so far been made in order to verify the applicability of JENDL-3 to various fields. For fast reactor calculations, JENDL-3 gives satisfactory results for most of characteristics. Particularly, space dependences of reaction rates, sodium void coefficients and control rod worths, which were significant with JENDL-2, nearly disappear. This suggests that the JENDL-3 data are well balanced. Satisfactory applicability has been also proved for the other field such as thermal reactor calculations, fusion neutronics, shielding and dosimetry. (orig.)

  5. The International Reactor Dosimetry File (IRDF-85)

    Cullen, D.E.; McLaughlin, P.K.

    1985-04-01

    This document describes the contents of the second version of the International Reactor Dosimetry File (IRDF-85), distributed by the Nuclear Data Section of the International Atomic Energy Agency. This library superseded IRDF-82. (author)

  6. Descriptive data of JENDL-3.2

    Shibata, Keiichi; Narita, Tsutomu [eds.; Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-02-01

    The second revision of JENDL-3 (JENDL-3.2) was released in 1994. The library contains evaluated neutron nuclear data for 340 nuclides which are needed for the design of fission and fusion reactors and for shielding calculation. This report presents a brief description of the evaluation method which is given in the File-1 part of JENDL-3.2. (author)

  7. Group cross-section processing method and common nuclear group cross-section library based on JENDL-3 nuclear data file

    Hasegawa, Akira

    1991-01-01

    A common group cross-section library has been developed in JAERI. This system is called 'JSSTDL-295n-104γ (neutron:295 gamma:104) group constants library system', which is composed of a common 295n-104γ group cross-section library based on JENDL-3 nuclear data file and its utility codes. This system is applicable to fast and fusion reactors. In this paper, firstly outline of group cross-section processing adopted in Prof. GROUCH-G/B system is described in detail which is a common step for all group cross-section library generation. Next available group cross-section libraries developed in Japan based on JENDL-3 are briefly reviewed. Lastly newly developed JSSTDL library system is presented with some special attention to the JENDL-3 data. (author)

  8. Second revised edition of JENDL-3 (JENDL-3,2)

    Kikuchi, Yasuyuki

    1995-01-01

    In Nuclear Data Center, Japan Atomic Energy Research Institute, the development of Japanese standard evaluated nuclear data library, JENDL, since the beginning of 1970s has been advanced. In June, 1994, the second revised edition of the third edition, JENDL-3,2, was opened to public. This JENDL-3,2 is expected to be utilized widely in Japan and abroad by freezing it for the time being as the final version of JENDL. This report is the contents of the publication of JENDL-3,2 of the title 'Present state of Japanese nuclear data activities' made at Physical Society of Japan in 1994. Nuclear data are divided into nuclear reaction data and nuclear structure data. The nuclear reaction data on neutron induction, evaluated nuclear data file and the international cooperation for nuclear data are described. The history of Japanese nuclear data activities, nuclear data libraries in the world and the history of JENDL are introduced. As for the evaluation of JENDL-3, its outline, light, medium and heavy nuclei, the nuclides of nuclear fission products, main actinide nuclides, transuranic elements and gamma ray generation data are reported. As for the bench mark test of JENDL-3,1, its outline, simple system bench mark, fast reactor system, thermal neutron reactor system, shield bench mark and feedback information from bench mark test are described. The evaluation and the bench mark test for LENDL-3,2 are reported. (K.I.)

  9. Verification of dosimetry cross sections above 10 MeV based on measurement of activation reaction rates in fission neutron field

    Odano, Naoteru; Miura, Toshimasa; Yamaji, Akio.

    1996-01-01

    To validate the dosimetry cross sections in fast neutron energy range, activation reaction rates were measured for 5 types of dosimetry cross sections which have sensitivity in the energy rage above 10 MeV utilizing JRR-4 reactor of JAERI. The measured reaction rates were compared with the calculations reaction rates by a continuous energy monte carlo code MVP. The calculated reaction rates were based on two dosimetry files, JENDL Dosimetry File and IRDF-90.2. (author)

  10. RRDF-98. Russian reactor dosimetry file. Summary documentation

    Pashchenko, A B

    1999-03-01

    This document summarizes the contents and documentation of the new version of tile Russian Reactor Dosimetry File (RRDF-98) released in December 1998 by the Russian Center on Nuclear Data (CJD) at the Institute of Physics and Power Engineering, Russian Federation. This file contains the original evaluations of cross section data and covariance matrixes for 22 reactions which are used for neutron flux dosimetry by foil activation. The majority of the evaluations included in previous versions of the Russian Reactor Dosimetry Files (BOSPOR-80, RRGF-94 and RRDF-96) have been superseded by new evaluations. The evaluated cross sections of RRDF-98 averaged over 252-Cf and 235-U fission spectra are compared with relevant integral data. The data file is available from the IAEA Nuclear Data Section on diskette, cost free. (author) 9 refs, 22 figs, 2 tabs

  11. RRDF-98. Russian reactor dosimetry file. Summary documentation

    Pashchenko, A.B.

    1999-01-01

    This document summarizes the contents and documentation of the new version of tile Russian Reactor Dosimetry File (RRDF-98) released in December 1998 by the Russian Center on Nuclear Data (CJD) at the Institute of Physics and Power Engineering, Russian Federation. This file contains the original evaluations of cross section data and covariance matrixes for 22 reactions which are used for neutron flux dosimetry by foil activation. The majority of the evaluations included in previous versions of the Russian Reactor Dosimetry Files (BOSPOR-80, RRGF-94 and RRDF-96) have been superseded by new evaluations. The evaluated cross sections of RRDF-98 averaged over 252-Cf and 235-U fission spectra are compared with relevant integral data. The data file is available from the IAEA Nuclear Data Section on diskette, cost free. (author)

  12. A study of existing experimental data and validation process for evaluated high energy nuclear data. Report of task force on integral test for JENDL High Energy File in Japanese Nuclear Data Committee

    Oyama, Yukio; Baba, Mamoru; Watanabe, Yukinobu

    1998-11-01

    JENDL High Energy File (JENDL-HE) is being produced by Japanese Nuclear Data Committee (JNDC) to provide common fundamental nuclear data in the intermediate energy region for many applications concerning a basic research, an accelerator-driven nuclear waste transmutation, a fusion material study, and medical applications like the radiation therapy. The first version of JENDL-HE, which contains the evaluated nuclear data up to 50 MeV, is planned to release in 1998. However, a method of integral test with which we can validate the high-energy nuclear data file has not been established. The validation of evaluated nuclear data through the integral tests is necessary to promote utilization of JENDL-HE. JNDC set up a task force in 1997 to discuss the problems concerning the integral tests of JENDL-HE. The task force members have surveyed and studied the current status of the problems for a year to obtain a guideline for development of the high-energy nuclear database. This report summarizes the results of the survey and study done by the task force for JNDC. (author)

  13. Status of the dosimetry file for ENDF/B-V

    Magurno, B.A.

    1979-01-01

    Since the new Dosimetry File will not be ready for distrubution until February-March, 1979, this presentation is submitted as a progress report where the schedule for release and dissemination of the library was reported. The dates of release and distribution were predicated on the use of pre-determined standards for use with the new Dosimetry File. Subsequently, one of the most important standards, i.e. 235 U (n,f) has been re-evaluated, causing the delay that is responsible for the above mentioned release date

  14. Status of thorium cycle nuclear data evaluations: Comparison of cross-section line shapes of JENDL-3 and ENDF-B-VI files for 230Th, 232Th, 231Pa, 233Pa, 232U, 233U and 234U

    Ganesan, S.; McLaughlin, P.K.

    1992-02-01

    Since 1990, one of the most interesting developments in the field of nuclear data for nuclear technology applications is that several new evaluated data files have been finalized and made available to the International Atomic Energy Agency (IAEA) for distribution to its Member States. Improved evaluated nuclear data libraries such as ENDF/B-VI from the United States and JENDL-3 from Japan were developed over a period of 10-15 years. This report is not an evaluation of the evaluations. The report as presented here gives a first look at the cross section line shapes of the isotopes that are important to the thorium fuel cycle derived from the two recently evaluated data files: JENDL-3 and ENDF/B-VI. The basic evaluated data files JENDL-3 and ENDF/B-VI were point-processed successfully using the codes LINEAR and RECENT. The point data were multigrouped in three different group structures using the GROUPIE code. Graphs of intercomparisons of cross section line shapes of JENDL-3 and ENDF/B-VI are presented in this paper for the following isotopes of major interest to studies of the thorium fuel cycle: 230 Th, 232 Th, 231 Pa, 233 Pa, 232 U, 233 U and 234 U. Comparisons between JENDL-3 and ENDF/B-VI which were performed at the point and group levels show large discrepancies in various cross sections. We conclude this report with a general remark that it is necessary to perform sensitivity studies to assess the impacts of the discrepancies between the two different sets of data on calculated reactor design and safety parameters of specific reactor systems and, based on the results of such sensitivity studies, to undertake new tasks of evaluations. (author). 2 refs, 245 figs, 8 tabs

  15. Important comments on KERMA factors and DPA cross-section data in ACE files of JENDL-4.0, JEFF-3.2 and ENDF/B-VII.1

    Konno, Chikara; Tada, Kenichi; Kwon, Saerom; Ohta, Masayuki; Sato, Satoshi

    2017-09-01

    We have studied reasons of differences of KERMA factors and DPA cross-section data among nuclear data libraries. Here the KERMA factors and DPA cross-section data included in the official ACE files of JENDL-4.0, ENDF/B-VII.1 and JEFF-3.2 are examined in more detail. As a result, it is newly found out that the KERMA factors and DPA cross-section data of a lot of nuclei are different among JENDL-4.0, ENDF/B-VII.1 and JEFF-3.2 and reasons of the differences are the followings: 1) large secondary particle production yield, 2) no secondary gamma data, 3) secondary gamma data in files12-15 mt = 3, 4) mt = 103-107 data without mt = 600 s-800 s data in file6. The issue 1) is considered to be due to nuclear data, while the issues 2)-4) seem to be due to NJOY. The ACE files of JENDL-4.0, ENDF/B-VII.1 and JEFF-3.2 with these problems should be revised after correcting wrong nuclear data and NJOY problems.

  16. Evaluation of fission product neutron cross sections for JENDL

    1984-01-01

    The recent activities on the evaluation of fission product (FP) neutron cross sections for JENDL (Japanese Evaluated Nuclear Data Library) are presented briefly. The integral test of JENDL-1 FP cross section file was performed using the CFRMF sample activation data and the STEK sample reactivity data, and the ratio of experiment to calculation was nearly constant for all the samples in the STEK measurement. Therefore, a tentative analysis was performed by applying the correction to the calculated scattering reactivity component. Better agreement with the experiment was obtained after applying this correction in most cases. The evaluation work on the JENDL-2 FP neutron cross sections is now in progress. The improvement of the data evaluation is presented in an itemized form. The JENDL-2 FP file will contain the evaluated data for 100 nuclides from Kr to Tb. The improvement and the future scope of the integral test for JENDL-2 FP data are summarized. (Asami, T.)

  17. Present status of JENDL-4

    Shibata, Keiichi

    2009-01-01

    The fourth version of Japanese Evaluated Nuclear Data Library is being developed at the JAEA Nuclear Data Center in cooperation with the Japanese Nuclear Data Committee. As for actinides, we already released JENDL Actinoid File 2008, which contains the evaluated data for 79 nuclei. The high-energy cross sections of FP nuclei have been evaluated by using the CCONE and POD statistical model codes. The nuclear data for structural materials and light nuclei are being revised. The fission product yields were updated on the basis of ENDF/B-VII.0. Ternary fission was included in the yield data. (author)

  18. Decay data file based on the ENSDF file

    Katakura, J. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    A decay data file with the JENDL (Japanese Evaluated Nuclear Data Library) format based on the ENSDF (Evaluated Nuclear Structure Data File) file was produced as a tentative one of special purpose files of JENDL. The problem using the ENSDF file as primary source data of the JENDL decay data file is presented. (author)

  19. Nuclear decay data files of the Dosimetry Research Group

    Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.; Cristy, M.

    1993-12-01

    This report documents the nuclear decay data files used by the Dosimetry Research Group at Oak Ridge National Laboratory and the utility DEXRAX which provides access to the files. The files are accessed, by nuclide, to extract information on the intensities and energies of the radiations associated with spontaneous nuclear transformation of the radionuclides. In addition, beta spectral data are available for all beta-emitting nuclides. Two collections of nuclear decay data are discussed. The larger collection contains data for 838 radionuclides, which includes the 825 radionuclides assembled during the preparation of Publications 30 and 38 of the International Commission on Radiological Protection (ICRP) and 13 additional nuclides evaluated in preparing a monograph for the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. The second collection is composed of data from the MIRD monograph and contains information for 242 radionuclides. Abridged tabulations of these data have been published by the ICRP in Publication 38 and by the Society of Nuclear Medicine in a monograph entitled ''MIRD: Radionuclide Data and Decay Schemes.'' The beta spectral data reported here have not been published by either organization. Electronic copies of the files and the utility, along with this report, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory

  20. Present Status of the JENDL Project (May, 2014)

    Iwamoto, Osamu; Yokoyama, Kenji

    2014-01-01

    The Japanese Nuclear Data Committee (JNDC) is a research committee for JAEA research activities. It has two subcommittees: Subcommittee on Nuclear Data and Subcommittee on Reactor Constants. The JENDL-4.0 Updated Files (JENDL-4.0u) have been produced to take care of errors which were found after the release of JENDL-4.0. The JENDL-4.0u includes the nuclides whose nuclear data partly revised from important and/or trivial error(s). Thirteen files for JENDL-4.0 were released in 2013. Benchmarking for fission reactor applications was done using test files of Gd-157 and Am-241, and an integral testing for Th-232 was done using KUCA critical experiments. The data which are not updated in JENDL-4.0 are continuously considered to be revised, especially for FP region nuclides. Evaluated results for 141,143 Pr, 121,123-126 Sb and 96,98-106 Ru were published. The R-matrix analysis for O-16 is in progress. For decommissioning of nuclear power plants, evaluation of activation cross sections was planned for 569 reactions with 309 nuclides and is in progress. Evaluated files for the 246 isotopes from H to Hf have been created. As the activity of High Energy Nuclear Data Evaluation WG, development of new JENDL Photonuclear Data File is in progress. Evaluation for 181 nuclides has been finished. A Symposium on Nuclear Data was held on 14-15 November 2013 at Research Institute of Nuclear Engineering, University of Fukui, Tsuruga-shi, with topics about Progress in neutron cross-section measurement and analysis, Application of Nuclear Data, Recent topics, and Progress in studies of high-energy nuclear reaction. A total of 37 papers including 23 poster presentations were presented

  1. ENDF/B-5 Dosimetry Files, mod. 2 1979/81

    DayDay, N.; Lemmel, H.D.

    1981-09-01

    This document summarizes the contents and documentation of the ENDF/B-5 Dosimetry Files (Point or Group Data) released in October 1979 and modified in August 1981. The files contain data for 36 neutron reactions of 26 isotopes. The entire libraries or selective retrievals from them can be obtained free of charge from the IAEA Nuclear Data Section. (author)

  2. Evaluation of resonance parameters of Mo, Tc, Te, Ba, La, Ce, Pr, Nd, Pm, Sm and Eu isotopes for JENDL-2 fission product file

    Kikuchi, Yasuyuki; Togawa, Orihiko; Nakagawa, Tsuneo

    1986-03-01

    The resonance parameters of 39 fission product nuclides have been evaluated. The present work is a part of the evaluation of 100 fission product nuclei for JENDL-2 by Japanese Nuclear Data Committee. All the available experimental data were collected, stored in REPSTOR system and compared with one another. The evaluation was made on the basis of the experimental data. The precise description of the evaluation is given in this report. The presently evaluated resonance parameters are tabulated in Appendix with the experimental data. (author)

  3. Japanese evaluated nuclear data library version 3, JENDL-3

    Asami, Tetsuo; Igarashi, Shun-ichi; Ihara, Hitoshi

    1989-01-01

    The third version of Japanese Evaluated Nuclear Data Library, JENDL-3, has recently been compiled and issued. The major features of JENDL-3 are that it covers a much larger number of nuclides than the previous versions, that evaluation is made over the all energy regions from 10 -5 eV to 20 MeV using proper nuclear theories for each of the energy regions, and that it contains data on gamma ray generation. The present report first gives an outline of JENDL-3, and then describes the evaluation of nuclear data covering light nuclides, nuclides in structural materials, fission product nuclides, major actinide nuclides, transplutonium nuclides, and gamma ray generation. The applicability of JENDL-3 is examined through a variety of bench mark tests covering the fast reactor, thermal neutron reactor, shielding, neutronics of nuclear fusion reactor, dosimetry, and gamma ray generation data. The report also describes a library for calculation of decay heat, which has close relations with JENDL-3. It has been demonstrated that the experimental data given in this library are very reliable with high reproducibility. Additional activities planned for the future are also outlined briefly. (N.K.)

  4. Final report of advisory subcommittee on development of JENDL. Guideline for developing next JENDL

    Chiba, Go; Iwamoto, Osamu

    2015-01-01

    Advisory Subcommittee on Development of JENDL was established under JENDL Committee on fiscal year 2013 to discuss the subject concerning on development of next JENDL. Members of the subcommittee were selected from developers and users of JENDL and researchers on nuclear data measurements. They discussed guidelines on next JENDL with exchanging ideas on problems of JENDL and its solution from each view point. This report describes the results of the discussions on the problems and guideline with the present status on the JENDL development. (author)

  5. Summary report of the final technical meeting on 'International Reactor Dosimetry File: IRDF-2002'

    Griffin, Patrick J.; Paviotti-Corcuera, R.

    2003-10-01

    Presentations, recommendations and conclusions of the Final Technical Meeting on 'International Reactor Dosimetry File: IRDF-2002' are summarized in this report. The main aims of this meeting were to discuss scientific and technical matters related to reactor dosimetry and to assign responsibilities for the preparation of the final version of the IRDF- 2002 library and the associated TECDOC. Tasks were assigned and deadlines were agreed. Participants emphasized that accurate and complete nuclear data for reactor dosimetry are essential to improve the assessment accuracies for reactor pressure vessel service lifetimes in nuclear power plants, as well as for other neutron metrology applications such as boron neutron capture therapy, therapeutic use of medical isotopes, nuclear physics measurements, and reactor safety applications. (author)

  6. Present status of JENDL-3.3

    Nakagawa, Tsuneo; Shibata, Keiichi

    2001-01-01

    The latest version of JENDL General Purpose Library, JENDL-3.3, is being compiled. The evaluations for JENDL-3.3 have been performed mainly by the Medium-Heavy Nuclide Data Evaluation WG, the Heavy Nuclide Data Evaluation WG and the Delayed Neutron WG in the Japanese Nuclear Data Committee. The main objective of the evaluations is to solve the problems that were pointed out in JENDL-3.2. (author)

  7. Descriptive data of JENDL-3.3

    Shibata, Keiichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-01-01

    The third revision of JENDL-3 (JENDL-3.3) was released in 2002. The library contains evaluated neutron nuclear data for 337 nuclides. This report presents a brief description of the evaluation method which is given in the MF1 part of JENDL-3.3. (author)

  8. Summary report of the technical meeting on 'International Reactor Dosimetry File: IRDF-2002'

    Greenwood, L.R.; Paviotti-Corcuera, R.

    2002-09-01

    This report summarizes the presentations, recommendations and conclusions of the Technical Meeting on 'International Reactor Dosimetry File: IRDF-2002.' The purpose of this meeting was to discuss scientific and technical matters related to the subject and coordinate related tasks. Discussions were held and recommendations were given for the preparation of the files on topics related to: reactions to be included, need for new evaluations or revisions, decay data, radiation damage data, integral testing in benchmark fields, and computer codes to be included. Tasks were assigned and deadlines were set. The participants emphasized that accurate and complete knowledge of nuclear data for reactor dosimetry are essential for improving the accuracy of the reactor pressure vessel service life assessment of nuclear power plants as well as in other neutron metrology applications such as boron neutron capture therapy, therapeutic use of medical isotopes, nuclear physics measurements, and reactor safety applications. (author)

  9. Status of data testing of ENDF/B-V reactor dosimetry file

    Magurno, B.A.

    1979-01-01

    The ENDF/B-V Reactor Dosimetry File was released August 1979, and Phase II data testing started. The results presented here are from Brookhaven National Laboratory only, and are considered preliminary. The tests include calculated spectrum-averaged cross sections using 235 U fission spectrum (Watt), 252 Cf spontaneous fission spectrum (Watt and Maxwellian), and the Coupled Fast Reactor Measurement Facility (CFRMF) spectrum. 6 tables

  10. Benchmark tests of JENDL-1

    Kikuchi, Yasuyuki; Hasegawa, Akira; Takano, Hideki; Kamei, Takanobu; Hojuyama, Takeshi; Sasaki, Makoto; Seki, Yuji; Zukeran, Atsushi; Otake, Iwao.

    1982-02-01

    Various benchmark tests were made on JENDL-1. At the first stage, various core center characteristics were tested for many critical assemblies with one-dimensional model. At the second stage, applicability of JENDL-1 was further tested to more sophisticated problems for MOZART and ZPPR-3 assemblies with two-dimensional model. It was proved that JENDL-1 predicted various quantities of fast reactors satisfactorily as a whole. However, the following problems were pointed out: 1) There exists discrepancy of 0.9% in the k sub(eff)-values between the Pu- and U-cores. 2) The fission rate ratio of 239 Pu to 235 U is underestimated by 3%. 3) The Doppler reactivity coefficients are overestimated by about 10%. 4) The control rod worths are underestimated by 4%. 5) The fission rates of 235 U and 239 Pu are underestimated considerably in the outer core and radial blanket regions. 6) The negative sodium void reactivities are overestimated, when the sodium is removed from the outer core. As a whole, most of problems of JENDL-1 seem to be related with the neutron leakage and the neutron spectrum. It was found through the further study that most of these problems came from too small diffusion coefficients and too large elastic removal cross sections above 100 keV, which might be probably caused by overestimation of the total and elastic scattering cross sections for structural materials in the unresolved resonance region up to several MeV. (author)

  11. Dosimetry

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  12. Dosimetry

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  13. Present Status of the JENDL Project (May, 2013). WPEC Meeting, Paris, France, 23-24 May, 2013

    Fukahori, Tokio; Iwamoto, Osamu; Ishikawa, Makoto

    2013-01-01

    This paper briefly presents the present status of the Japanese JENDL Project: organization of Japanese Nuclear Data Committee (JNDC), a research committee for JAEA research activities; Nuclear Data Evaluation (JENDL-4.0 Updated Files and JENDL-4.0 Plus, benchmarking for fission reactor applications (criticality for thermal systems, adjusted library for fast systems), new evaluations, covariances, evaluation tools, fission products decay data file); other activities such as the 2012 Symposium on Nuclear Data at Kyoto University Research Reactor Institute, the initiation of conversation on Covariance Data with users, the celebration of the Golden Jubilee (since 1963) of JNDC

  14. Present status of libraries processed from JENDL-3.2

    Yamano, Naoki

    1996-01-01

    Data libraries processed from JENDL-3.2 were produced by JAERI for use of typical applications in the area of nuclear reactor and shielding. These libraries had the distinction of being free of restrictions on distribution. The other data libraries for decay, activation, dosimetry, nuclide transmutation, burn-up, PKA, KERMA and DPA calculations are now being accumulated. The current status on the development of these libraries has been described. A discussion is presented about how to disseminate and share the products of JNDC activities. (author)

  15. Final report of advisory subcommittee on development of JENDL. Guideline for developing next JENDL

    Chiba, Go

    2016-01-01

    An advisory subcommittee on development of JENDL was established in 2013 to discuss future development of JENDL among experts on nuclear data experiments, evaluations and applications. This paper is a summary of a final report which was submitted to the JENDL committee on March in 2014. (author)

  16. Estimation of covariances of Cr and Ni neutron nuclear data in JENDL-3.2

    Shibata, Keiichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Oh, Soo Youl [Korea Atomic Energy Research Institute, Taejon (Korea)

    2000-02-01

    Covariances of nuclear data have been estimated for 2 nuclides contained in JENDL-3.2. The nuclides considered are Cr and Ni, which are regarded as important for the nuclear design study of fast reactors. The physical quantities for which covariances are deduced are cross sections and the first order Legendre-polynomial coefficient for the angular distribution of elastically scattered neutrons. The covariances were estimated by using the same methodology that had been used in the JENDL-3.2 evaluation in order to keep a consistency between mean values and their covariances. The least-squares fitting code GMA was used in estimating covariances for reactions of which JENDL-3.2 cross sections had been evaluated by taking account of measurements. Covariances of nuclear model calculations were deduced by using the KALMAN system. The covariance data obtained were compiled in the ENDF-6 format, and will be put into the JENDL-3.2 Covariance File which is one of JENDL special purpose files. (author)

  17. Current status of JENDL-3.3

    Hasegawa, Akira [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Current status of JENDL-3.3 is presented. Reevaluation work toward JENDL-3.3 has started last April for three years project to supply a consolidated new versions of JENDL by JAERI NDC (Nuclear Data center) with the cooperation of JNDC (Japanese Nuclear Data Committee). The working schedule has been fixed by the careful review of the summary report, `The problems of JENDL-3.2`, submitted to JNDC last March after one year discussions by a small advisory group: `Identifying the problems of JENDL-3.2`. To cope with the problems, two new subgroups are set up in the Subcommittee of Nuclear Data of JNDC. One is Heavy Mass Elements Evaluation Working Group for the re-evaluation of major actinides (Th-232, U-233,235,236,238, Pu-236,239,241,242). The other is Intermediate Mass Elements Evaluation Working Group for solving the inconsistencies between calculations and integral experiments relating to the fields of fusion neutronics and shielding applications as well as new evaluations such as Er elements. Supplying covariance data for important nuclides are one of the main feature of JENDL-3.3. Re-evaluated data will be released as JENDL-3.3 in the individual bases after the reviewing process by the experts. (author)

  18. Usage of nuclear data library and proposal to JENDL

    Sasaki, M.; Iijima, S.; Kawai, Y.; Matsunobu, H.; Zukeran, A.

    1987-01-01

    A usage status of nuclear data libraries and proposals to the JENDL library are briefly reviewed. 1) Data bases used in plant design and fuel cycle design fields are summarized. JNDC evaluated data and JENDL are not utilized so much than expected in these fields. 2) Performances between JENDL-2 and ENDF/B-IV are compared in the FBR nuclear design field. JENDL-2 shows good characteristics. 3) Usages of JENDL-2 are shown in the LWR nuclear design field. JENDL-2 isn't always superior to the licensing library. 4) Usages of JENDL-2 are shown in the FBR shielding R D field. JENDL-2 underestimates measured spectra in case of the deep penetration experiment. 5) Based on the above usage status of JENDL-2, proposals to future JENDL and Nuclear Data Center are tabulated. (author)

  19. ERRORJ. Covariance processing code system for JENDL. Version 2

    Chiba, Gou

    2003-09-01

    ERRORJ is the covariance processing code system for Japanese Evaluated Nuclear Data Library (JENDL) that can produce group-averaged covariance data to apply it to the uncertainty analysis of nuclear characteristics. ERRORJ can treat the covariance data for cross sections including resonance parameters as well as angular distributions and energy distributions of secondary neutrons which could not be dealt with by former covariance processing codes. In addition, ERRORJ can treat various forms of multi-group cross section and produce multi-group covariance file with various formats. This document describes an outline of ERRORJ and how to use it. (author)

  20. Benchmark tests of JENDL-3.2 for thermal and fast reactors

    Takano, Hideki

    1995-01-01

    Benchmark calculations for a variety of thermal and fast reactors have been performed by using the newly evaluated JENDL-3 Version-2 (JENDL-3.2) file. In the thermal reactor calculations for the uranium and plutonium fueled cores of TRX and TCA, the k eff and lattice parameters were well predicted. The fast reactor calculations for ZPPR-9 and FCA assemblies showed that the k eff , reactivity worth of Doppler, sodium void and control rod, and reaction rate distribution were in a very good agreement with the experiments. (author)

  1. Dosimetry

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, gamma) process in Na sup 2 sup 3 , giving rise to Na sup 2 sup 4 , which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na sup 2 sup 4 , is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na sup 2 sup 3 in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na sup 2 sup 4 /Na sup 2 sup 3 in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R sub B reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzmann transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given

  2. Dosimetry

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-01

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, {gamma}) process in Na{sup 23}, giving rise to Na{sup 24}, which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na{sup 24}, is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na{sup 23} in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na{sup 24}/Na{sup 23} in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R{sub B} reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzman transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given. A summary of the 4{pi

  3. Summary remarks and recommended reactions for an international data file for dosimetry applications for LWR, FBR, and MFR reactor research, development and testing programs

    McElroy, W.N.; Lippincott, E.P.; Grundl, J.A.; Fabry, A.; Dierckx, R.; Farinelli, U.

    1979-01-01

    The need for the use of an internationally accepted data file for dosimetry applications for light water reactor (LWR), fast breeder reactor (FBR), and magnetic fusion reactor (MFR) research, development, and testing programs continues to exist for the Nuclear Industry. The work of this IAEA meeting, therefore, will be another important step in achieving consensus agreement on an internationally recommended file and its purpose, content, structure, selected reactions, and associated uncertainy files. Summary remarks and a listing of recommended reactions for consideration in the formulation of an ''International Data File for Dosimetry Applications'' are presented in subsequent sections of this report

  4. Sensitivity analysis of Monju using ERANOS with JENDL-4.0

    Tamagno, P.; Van Rooijen, W. F. G.; Takeda, T.; Konomura, M.

    2012-01-01

    This paper deals with sensitivity analysis using JENDL-4.0 nuclear data applied to the Monju reactor. In 2010 the Japan Atomic Energy Agency - JAEA - released a new set of nuclear data: JENDL-4.0. This new evaluation is expected to contain improved data on actinides and covariance matrices. Covariance matrices are a key point in quantification of uncertainties due to basic nuclear data. For sensitivity analysis, the well-established ERANOS [1] code was chosen because of its integrated modules that allow users to perform a sensitivity analysis of complex reactor geometries. A JENDL-4.0 cross-section library is not available for ERANOS. Therefore a cross-section library had to be made from the original nuclear data set, available as ENDF formatted files. This is achieved by using the following codes: NJOY, CALENDF, MERGE and GECCO in order to create a library for the ECCO cell code (part of ERANOS). In order to make sure of the accuracy of the new ECCO library, two benchmark experiments have been analyzed: the MZA and MZB cores of the MOZART program measured at the ZEBRA facility in the UK. These were chosen due to their similarity to the Monju core. Using the JENDL-4.0 ECCO library we have analyzed the criticality of Monju during the restart in 2010. We have obtained good agreement with the measured criticality. Perturbation calculations have been performed between JENDL-3.3 and JENDL-4.0 based models. The isotopes 239 Pu, 238 U, 241 Am and 241 Pu account for a major part of observed differences. (authors)

  5. Sensitivity analysis of Monju using ERANOS with JENDL-4.0

    Tamagno, P. [Institut National des Sciences et Techniques Nucleaires, INSTN - Point Courrier no 35, Centre CEA de Saclay, F-91191 Gif-sur-Yvette Cedex (France); Van Rooijen, W. F. G.; Takeda, T. [Research Inst. of Nuclear Engineering, Univ. of Fukui, Kanawa-cho 1-2-4, T914-0055 Fukui-ken, Tsuruga-shi (Japan); Konomura, M. [Japan Atomic Energy Agency, FBR Plant Engineering Center, Shiraki 1, 919-1279 Fukui-ken, Tsuruga-shi (Japan)

    2012-07-01

    This paper deals with sensitivity analysis using JENDL-4.0 nuclear data applied to the Monju reactor. In 2010 the Japan Atomic Energy Agency - JAEA - released a new set of nuclear data: JENDL-4.0. This new evaluation is expected to contain improved data on actinides and covariance matrices. Covariance matrices are a key point in quantification of uncertainties due to basic nuclear data. For sensitivity analysis, the well-established ERANOS [1] code was chosen because of its integrated modules that allow users to perform a sensitivity analysis of complex reactor geometries. A JENDL-4.0 cross-section library is not available for ERANOS. Therefore a cross-section library had to be made from the original nuclear data set, available as ENDF formatted files. This is achieved by using the following codes: NJOY, CALENDF, MERGE and GECCO in order to create a library for the ECCO cell code (part of ERANOS). In order to make sure of the accuracy of the new ECCO library, two benchmark experiments have been analyzed: the MZA and MZB cores of the MOZART program measured at the ZEBRA facility in the UK. These were chosen due to their similarity to the Monju core. Using the JENDL-4.0 ECCO library we have analyzed the criticality of Monju during the restart in 2010. We have obtained good agreement with the measured criticality. Perturbation calculations have been performed between JENDL-3.3 and JENDL-4.0 based models. The isotopes {sup 239}Pu, {sup 238}U, {sup 241}Am and {sup 241}Pu account for a major part of observed differences. (authors)

  6. Shielding benchmark tests of JENDL-3

    Kawai, Masayoshi; Hasegawa, Akira; Ueki, Kohtaro; Yamano, Naoki; Sasaki, Kenji; Matsumoto, Yoshihiro; Takemura, Morio; Ohtani, Nobuo; Sakurai, Kiyoshi.

    1994-03-01

    The integral test of neutron cross sections for major shielding materials in JENDL-3 has been performed by analyzing various shielding benchmark experiments. For the fission-like neutron source problem, the following experiments are analyzed: (1) ORNL Broomstick experiments for oxygen, iron and sodium, (2) ASPIS deep penetration experiments for iron, (3) ORNL neutron transmission experiments for iron, stainless steel, sodium and graphite, (4) KfK leakage spectrum measurements from iron spheres, (5) RPI angular neutron spectrum measurements in a graphite block. For D-T neutron source problem, the following two experiments are analyzed: (6) LLNL leakage spectrum measurements from spheres of iron and graphite, and (7) JAERI-FNS angular neutron spectrum measurements on beryllium and graphite slabs. Analyses have been performed using the radiation transport codes: ANISN(1D Sn), DIAC(1D Sn), DOT3.5(2D Sn) and MCNP(3D point Monte Carlo). The group cross sections for Sn transport calculations are generated with the code systems PROF-GROUCH-G/B and RADHEAT-V4. The point-wise cross sections for MCNP are produced with NJOY. For comparison, the analyses with JENDL-2 and ENDF/B-IV have been also carried out. The calculations using JENDL-3 show overall agreement with the experimental data as well as those with ENDF/B-IV. Particularly, JENDL-3 gives better results than JENDL-2 and ENDF/B-IV for sodium. It has been concluded that JENDL-3 is very applicable for fission and fusion reactor shielding analyses. (author)

  7. Evaluation of 54Fe(n,2n)53m+gFe reaction cross sections for high energy dosimetry applications

    Zolotarev, K.I.; Pashchenko, A.B.

    2001-01-01

    The new evaluation of excitation function for the high energy threshold 54 Fe(n,2n) 53m+g Fe dosimetry reaction in the energy range from the threshold to 20 MeV is briefly described. The cross section uncertainties and the covariance matrix were estimated simultaneously from the analysis. The adopted curve is compared to the available processed experimental data and the existing FEI-93, ENDF/B-VI and JENDL-3.2 evaluations. The ENDF-6 formatted data file is available from the Web site of the Russian Nuclear Data Center (RNDC) online (http://www.rndc.ippe.obninsk.ru). (author)

  8. Status of LWR fuel design and future usage of JENDL

    Ito, Takuya

    2008-01-01

    For all conventional LWR fuel design codes of LWR fuel manufactures in Japan, the cross section library are based on the ENDF/B. Recently we can see several movements for the utilization of JENDL library for the LWR fuel design. The latest version of NEUPHYS cross section library is based on the JENDL-3.2. To accelerate this movement of JENDL utilization in LWR fuel design, it is necessary to prepare a high quality JENDL document, systematic validation of JENDL and to appeal them abroad effectively. (author)

  9. Evaluation of covariance data for chromium, iron and nickel contained in JENDL-3.2

    Oh, Soo-Youl; Shibata, Keiichi.

    1998-01-01

    An evaluation has been made for the covariances of neutron cross sections of 52 Cr, 56 Fe, 58 Ni and 60 Ni contained in JENDL-3.2. Reactions considered were the threshold reactions such as (n, 2n), (n, nα), (n, np), (n, p), (n, d), (n, t) and (n, α), the radiative capture reaction above the resonance region, and the inelastic scattering to discrete and continuum levels. Evaluation guidelines and procedures were established during the work. A generalized least-squares fitting code GMA was used in estimating covariances for reactions of which JENDL-3.2 cross sections had been evaluated by taking account of many measured data. For cross sections that had been evaluated by nuclear reaction model calculations, the KALMAN code, which yields covariances of cross sections and of associated model parameters on the basis of the Bayesian statistics, was used in conjunction with reaction model codes EGNASH and CASTHY. The evaluated uncertainties of a few percent to 30% in the cross sections look reasonable, and the correlation matrices show understandable trends. Even though there is no strict way to confirm the validity of the evaluated covariances, tools and procedures adopted in the present work are appropriate for producing covariance files based on JENDL-3.2. The covariances obtained will be compiled into JENDL in the near future. Meanwhile, new sets of optical model and level density parameters were proposed as one of byproducts obtained from the KALMAN calculations. (author)

  10. Thermal reactor benchmark tests on JENDL-2

    Takano, Hideki; Tsuchihashi, Keichiro; Yamane, Tsuyoshi; Akino, Fujiyoshi; Ishiguro, Yukio; Ido, Masaru.

    1983-11-01

    A group constant library for the thermal reactor standard nuclear design code system SRAC was produced by using the evaluated nuclear data JENDL-2. Furthermore, the group constants for 235 U were calculated also from ENDF/B-V. Thermal reactor benchmark calculations were performed using the produced group constant library. The selected benchmark cores are two water-moderated lattices (TRX-1 and 2), two heavy water-moderated cores (DCA and ETA-1), two graphite-moderated cores (SHE-8 and 13) and eight critical experiments for critical safety. The effective multiplication factors and lattice cell parameters were calculated and compared with the experimental values. The results are summarized as follows. (1) Effective multiplication factors: The results by JENDL-2 are considerably improved in comparison with ones by ENDF/B-IV. The best agreement is obtained by using JENDL-2 and ENDF/B-V (only 235 U) data. (2) Lattice cell parameters: For the rho 28 (the ratio of epithermal to thermal 238 U captures) and C* (the ratio of 238 U captures to 235 U fissions), the values calculated by JENDL-2 are in good agreement with the experimental values. The rho 28 (the ratio of 238 U to 235 U fissions) are overestimated as found also for the fast reactor benchmarks. The rho 02 (the ratio of epithermal to thermal 232 Th captures) calculated by JENDL-2 or ENDF/B-IV are considerably underestimated. The functions of the SRAC system have been continued to be extended according to the needs of its users. A brief description will be given, in Appendix B, to the extended parts of the SRAC system together with the input specification. (author)

  11. Evaluation of the excitation function for the dosimetry reaction La-139(n,g)La-140

    Zolotarev, K.

    1997-01-01

    The activation detectors on the basis of La-139(n,g)La-140 reaction are used very often in the reactor dosimetry for determination of thermal and epithermal components of neutron spectra. At present, the cross section data for this reaction are absent in the IRDF-90 ver.2 file and in the national dosimetry files such as ENDF/B-VI Dosimetry File and JENDL-3.2 Dosimetry File. The evaluation of the La-139(n,g)La-140 reaction excitation function for the Russian Reactor Dosimetry File (RRDF-96) was carried out in the energy region 1.000E-05 eV - 20 MeV. The capture cross section in the energy range from 0.00001 eV to 160 keV is given through the evaluated MLBW resolved and unresolved resonance parameters. Small background cross section was added in the resolved resonance region for taking into account the non-statistical reaction mechanism contribution. Data for En=160 keV - 1.2 MeV were obtained from evaluated average parameters in the unresolved resonance region with taking into account the competition with the neutron inelastic channels. The La-139 radiative capture cross section between 1.2 MeV and 7.6 MeV was evaluated by means of statistical analysis of the experimental data. Above 7.6 MeV the data fit was joint to the theoretical capture cross sections calculated between 7.6 and 20 MeV. Theoretical results were normalized to the evaluated value obtained from analysis experimental data at En= 14.4 - 14.8 MeV. The results of the present evaluation were compared with the ENDF/B-VI cross section data and the recommended values of resonance integral and capture cross section at En=0.0253 eV. (author)

  12. Validation of JENDL-3.3 by criticality benchmark testing

    Takano, Hideki; Nakagawa, Tsuneo

    2001-01-01

    In the thermal uranium core, the keff-values of STACY, TRACY and JRR-4 overestimated with JENDL-3.2 were improved significantly by decreasing of about 0.6% with JENDL-3.3. This is due to modification of the fission spectrum and thermal fission cross section of 235 U from JENDL-3.2 to JENDL-3.3 data. For the uranium fast cores, the discrepancies of keff values between JENDL-3.2 and 3.3 were very small. In the thermal Pu cores of TCA, the keff-values calculated with JENDL-3.3 were in good agreement with the experimental values. For Pu fuel cores of ZPPR-9 and FCA-XVII, the keff values calculated with JENDL-3.3 became larger 0.2% than those for JENDL-3.2. In small fast cores with U-233 fuel, the keff-values overestimated with JENDL-3.2 were improved considerably with JENDL-3.3, due to reevaluation of U-233 fission cross sections in the high energy region. (author)

  13. Validation of JENDL-3.3 for the HTTR criticality

    Goto, Minoru; Nojiri, Naoki; Shimakawa, Satoshi

    2004-01-01

    Validation of JENDL-3.3 has been performed for the HTTR criticality using the MVP code with a ''lattice-cell'' of infinite models and a ''whole-core'' of finite models. It was found that the keff values calculated with JENDL-3.3 was decreased about 0.2-0.4%Δk from one with JENDL-3.2. The criticality prediction was closed to the experimental data in the critical approach situation of the HTTR. (author)

  14. Present status and plans of JENDL FP data evaluation project

    Kawano, Toshihiko

    2003-01-01

    The Fission Product (FP) data evaluation is one of the key issues for the next revision of JENDL, since many data were carried over from JENDL-3.2 to 3.3. The new FP Working Group (FPWG) was organized in the Japanese Nuclear Data Committee (JNDC) to perform new evaluations of FP data for JENDL. In the present review of FP data evaluation, we show the history and current status of FP nuclear data, requirements of FP data, new measurements, the international cooperation, and the future plans toward the new JENDL. (author)

  15. Review of benchmark tests on JENDL-2B library

    Kikuchi, Yasuyuki

    1982-01-01

    JENDL-2B is a mixed library consisting of JENDL-2 for the most important nuclides, i.e., 235 U, 238 U, 239 Pu, 240 Pu, 241 Pu, Cr, Fe and Ni and of JENDL-1 for other nuclides. Complete reevaluation work was made for these eight nuclides. The simultaneous evaluation method was adopted in the evaluation for the five heavy nuclides. The resonance structure was carefully studied for the structural materials in the unresolved resonance region up to several MeV. Benchmark tests have been made on JENDL-2B. Various core center characteristics were tested with one-dimensional model for total of 27 assemblies. Satisfactory results were obtained as a whole. The results of spectrum indices, however, suggested some inconsistent spectrum prediction. Moreover, the reactivity worths were overestimated for most of materials, and apparent C/E discrepancies were observed between the Pu and U cores. Applicability of JENDL-2B was further tested to more sophisticated problems for MOZART and ZPPR-3 assemblies. The reaction rate distributions were better predicted with JENDL-2B than with JENDL-1. The positive sodium void reactivity worth was much overestimated with JENDL-2B due to too large moderation components. The control rod worths were well predicted in MOZART, but were considerably underpredicted in ZPPR-3. (author)

  16. Integral benchmark test of JENDL-4.0 for U-233 systems with ICSBEP handbook

    Kuwagaki, Kazuki; Nagaya, Yasunobu

    2017-03-01

    The integral benchmark test of JENDL-4.0 for U-233 systems using the continuous-energy Monte Carlo code MVP was conducted. The previous benchmark test was performed only for U-233 thermal solution and fast metallic systems in the ICSBEP handbook. In this study, MVP input files were prepared for uninvestigated benchmark problems in the handbook including compound thermal systems (mainly lattice systems) and integral benchmark test was performed. The prediction accuracy of JENDL-4.0 was evaluated for effective multiplication factors (k eff 's) of the U-233 systems. As a result, a trend of underestimation was observed for all the categories of U-233 systems. In the benchmark test of ENDF/B-VII.1 for U-233 systems with the ICSBEP handbook, it is reported that a decreasing trend of calculated k eff values in association with a parameter ATFF (Above-Thermal Fission Fraction) is observed. The ATFF values were also calculated in this benchmark test of JENDL-4.0 and the same trend as ENDF/B-VII.1 was observed. A CD-ROM is attached as an appendix. (J.P.N.)

  17. Estimation of covariances of 16O, 23Na, Fe, 235U, 238U and 239Pu neutron nuclear data in JENDL-3.2

    Shibata, Keiichi; Nakajima, Yutaka; Kawano, Toshihiko; Oh, Soo-Youl; Matsunobu, Hiroyuki; Murata, Toru.

    1997-10-01

    Covariances of nuclear data have been estimated for 6 nuclides contained in JENDL-3.2. The nuclides considered are 16 O, 23 Na, Fe, 235 U, 238 U, and 239 Pu, which are regarded as important for the nuclear design study of fast reactors. The physical quantities for which covariances are deduced are cross sections, resolved and unresolved resonance parameters, and the first order Legendre-polynomial coefficient for the angular distribution of elastically scattered neutrons. As for 235 U, covariances were obtained also for the average number of neutrons emitted in fission. The covariances were estimated by using the same methodology that had been used in the JENDL-3.2 evaluation in order to keep a consistency between mean values and their covariances. The least-squares fitting code GMA was used in estimating covariances for reactions of which JENDL-3.2 cross sections had been evaluated by taking account of measurements. In nuclear model calculations, the covariances were calculated by the KALMAN system. The covariance data obtained were compiled in the ENDF-6 format, and will be put into the JENDL-3.2 Covariance File which is one of JENDL special purpose files. (author). 193 refs

  18. Consistency between data from the ENDF/B-V dosimetry file and corresponding experimental data for some fast neutron reference spectra

    Nolthenius, H.J.; Zijp, W.L.

    1981-11-01

    Results are given of a study on the consistency between 'integral' and 'differential' cross sections data for four benchmark neutron spectra and 36 neutron reactions of importance for reactor neutron metrology. The energy dependent cross section data and their uncertainty data are obtained from the ENDF/B-V dosimetry file. The reactions have been considered with respect to the following quantities: 1. the precision of the averaged cross sections, for a specified spectrum; 2. the discrepancy between the measured and the calculated average cross section values; 3. the consistency between the measured and calculated average cross section values, described by the chi 2 -parameter. It was possible to take into account the available cross section covariance information present in the ENDF/B-V dosimetry file. Covariance information on the benchmark flux density spectra was not taken into account in this study

  19. Computer program system for evaluation of FP nuclear data for JENDL. Smooth part

    Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Watanabe, Takashi; Iijima, Shungo

    1997-12-01

    This report describes computer programs used to evaluate nuclear data of fission product (FP) nuclides stored in an evaluated nuclear data library JENDL, especially in the smooth part above the resonance region. Many programs were used for determination of nuclear model parameters, calculation of nuclear data, handling of experimental and/or calculated data, and so on. Among them, reported here are programs for determination of level density parameters (ENSDFRET, LVLPLOT, LEVDES), for making sets of JCL and input data for the theoretical calculation program CASTHY (JOBSETTER, INDES/CASTHY), and for conversion of format of CASTHY output files to the ENDF format (CTOB2). (author). 51 refs.

  20. Integral test of International Reactor Dosimetry and Fusion File with Li{sub 2}O assembly and DT neutron source at JAEA/FNS

    Sato, Satoshi, E-mail: sato.satoshi92@jaea.go.jp [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Kwon, Saerom; Ohta, Masayuki [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Ochiai, Kentaro [Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori-ken (Japan); Konno, Chikara [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan)

    2016-11-01

    In order to validate a new library of dosimetry cross section data, International Reactor Dosimetry and Fusion File release 1.0 (IRDFF 1.0), not only for DT neutrons but also for neutrons with energy of less than 14 MeV, we perform an integral test with a Li{sub 2}O rectangular assembly of 60.7 cm in thickness and a DT neutron source at JAEA/FNS. We place a lot of activation foils at depths of 10.1 cm and 30.4 cm for measurements of dosimetry reaction rates in small space along the central axis in the assembly, measure decay gamma-rays from the activation foils with high-purity Ge detectors after the DT neutron irradiation by the foil activation technique, and deduce a variety of dosimetry reaction rates. We calculate the reaction rates by using a Monte Carlo code MCNP5-1.40 and the nuclear data library ENDF/B-VII.1 with the IRDFF-v.1.05 as the response functions for the dosimetry reactions. The calculation results generally show good agreements with the measured ones, and it can be confirmed that most of the data in IRDFF-v.1.05 are valid for the neutron field in the Li{sub 2}O assembly with the DT neutrons.

  1. Analysis of JUPITER critical experiments by JENDL-3.2

    Ishikawa, Makoto

    1996-01-01

    Applicability of the JENDL-3.2 library to large FBR cores was evaluated using JUPITER experimental data. The nuclear characteristics treated in the present report include criticality, reaction rate ratio, space dependency of C/E values, sodium void reactivity and Doppler reactivity. As a conclusion, JENDL-3.2 is judged to be a well-balanced library for prediction of large FBR core parameters. The unification of integral experimental information from JUPITER and differential nuclear data of JENDL-3.2 will enhance the accuracy and reliability of large FBR core design. (author)

  2. JENDL. Nuclear databases for science and technology

    Shibata, Keiichi

    2013-01-01

    It is exactly 50 years since the Japanese Nuclear Data Committee was founded both in the Atomic Energy Society of Japan and in the former Japan Atomic Energy Research Institute. The committee promoted the development of Japan's own evaluated nuclear data libraries. As a result, we managed to produce a series of Japanese Evaluated Nuclear Data Libraries (JENDLs) to be used in various fields for science and technology. The libraries are categorized into general-purpose and special-purpose ones. The general-purpose libraries have been updated periodically by considering the latest knowledge on experimental and theoretical nuclear physics that was available at the time of the updates. On the other hand, the special-purpose libraries have been issued in order to meet the needs for particular application fields. This paper reviews the research and development for those libraries. (author)

  3. Integral test of JENDL-3.3 for thermal reactors

    Okumura, Keisuke; Mori, Takamasa

    2003-01-01

    Criticality benchmark testing was carried out for 59 experiments in various thermal reactors using a continues-energy Monte Carlo code MVP and its different libraries generated from JENDL-3.2, JENDL-3.3, JEF-2.2 and ENDF/B-VI (R8). From the benchmark results, we can say JENDL-3.3 generally gives better k eff values compared with other nuclear data libraries. However, further modification of JENDL-3.3 is expected to solve the following problems: 1) systematic underestimation of k eff depending on 235 U enrichment for the cores with low (less than 3wt.%) enriched uranium fueled cores, 2) dependence of C/E value of k eff on neutron spectrum and plutonium composition for MOX fueled cores. These are common problems for all of the nuclear data libraries used in this study. (author)

  4. JENDL-4.0 benchmarking for fission reactor applications

    Chiba, Go; Okumura, Keisuke; Sugino, Kazuteru; Nagaya, Yasunobu; Yokoyama, Kenji; Kugo, Teruhiko; Ishikawa, Makoto; Okajima, Shigeaki

    2011-01-01

    Benchmark testing for the newly developed Japanese evaluated nuclear data library JENDL-4.0 is carried out by using a huge amount of integral data. Benchmark calculations are performed with a continuous-energy Monte Carlo code and with the deterministic procedure, which has been developed for fast reactor analyses in Japan. Through the present benchmark testing using a wide range of benchmark data, significant improvement in the performance of JENDL-4.0 for fission reactor applications is clearly demonstrated in comparison with the former library JENDL-3.3. Much more accurate and reliable prediction for neutronic parameters for both thermal and fast reactors becomes possible by using the library JENDL-4.0. (author)

  5. JENDL-3. The Japanese evaluated nuclear data library

    Lemmel, H.D.

    1992-01-01

    This document summarizes the contents of JENDL-3.1, the Japanese evaluated data library for neutron nuclear data, released in 1989 and revised in Dec. 1990. It also summarizes the JENDL-3 fission-products cross-section data library released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  6. JENDL-3.3 thermal reactor benchmark test

    Akie, Hiroshi

    2001-01-01

    Integral tests of JENDL-3.2 nuclear data library have been carried out by Reactor Integral Test WG of Japanese Nuclear Data Committee. The most important problem in the thermal reactor benchmark testing was the overestimation of the multiplication factor of the U fueled cores. With several revisions of the data of 235 U and the other nuclides, JENDL-3.3 data library gives a good estimation of multiplication factors both for U and Pu fueled thermal reactors. (author)

  7. Critical and subcritical mass calculations of fissionable nuclides based on JENDL-3.2+

    Okuno, H.

    2002-01-01

    We calculated critical and subcritical masses of 10 fissionable actinides ( 233 U, 235 U, 238 Pu, 239 Pu, 241 Pu, 242m Am, 243 Cm, 244 Cm, 249 Cf and 251 Cf) in metal and in metal-water mixtures (except 238 Pu and 244 Cm). The calculation was made with a combination of a continuous energy Monte Carlo neutron transport code, MCNP-4B2, and the latest released version of the Japanese Evaluated Nuclear Data Library, JENDL-3.2. Other evaluated nuclear data files, ENDF/B-VI, JEF-2.2, and JENDL-3.3 in its preliminary version were also applied to find differences in results originated from different nuclear data files. For the so-called big three fissiles ( 233 U, 235 U and 239 Pu), analyzing the criticality experiments cited in ICSBEP Handbook validated the code-library combination, and calculation errors were consequently evaluated. Estimated critical and lower limit critical masses of the big three in a sphere with/without a water or SS-304 reflector were supplied, and they were compared with the subcritical mass limits of ANS-8.1. (author)

  8. Status of neutron dosimetry cross sections

    Griffin, P.J.; Kelly, J.G.

    1992-01-01

    Several new cross section libraries, such as ENDF/B-VI(release 2), IRDF-90,JEF-2.2, and JENDL-3 Dosimetry, have recently been made available to the dosimetry community. the Sandia National Laboratories (SNL) Radiation Metrology Laboratory (RML) has worked with these libraries since pre-release versions were available. this paper summarizes the results of the intercomparison and testing of dosimetry cross sections. As a result of this analysis, a compendium of the best dosimetry cross sections was assembled from the available libraries for use within the SNL RML. this library, referred to as the SNLRML Library, contains 66 general dosimetry sensors and 3 special dosimeters unique to the RML sensor inventory. The SNLRML cross sections have been put into a format compatible with commonly used spectrum determination codes

  9. Summary report of consultants' meeting to review the requirements to improve and extend the IRDF library (International Reactor Dosimetry File (IRDF-2002))

    Greenwood, L.R.; Nichols, A.L.

    2007-01-01

    Presentations, recommendations and conclusions of a Consultants' Meeting to 'Review the Requirements to Improve and Extend the IRDF library (International Reactor Dosimetry File (IRDF-2002))' are summarized is this report. The main aims of this meeting were to discuss scientific and technical matters related to reactor dosimetry and to consider the needs for improvements to the existing data in IRDF-2002 and possible extensions to other higher neutron energy applications. Specific tasks were assigned and deadlines agreed. The requirements for fusion studies are particularly challenging (up to 60 MeV) and should include adequate covariance data - the provision of these neutron cross sections will require additional effort and assessment prior to initiating any work programme, and specific participants agreed to undertake preliminary exercises. (author)

  10. Analysis of reactivity characteristics of the MONJU initial core using JENDL-3.2

    Sasaki, Kenji; Suzuki, Takayuki; Suzuki, Norimichi [Power Reactor and Nuclear Fuel Development Corp., Tsuruga, Fukui (Japan). Monju Construction Office; Itagaki, Yoshihiko

    1998-03-01

    This paper describes the evaluated results of criticality, absorber rod worth and coolant worth in the MONJU initial cores based on the JENDL-3.2 library compared with those of the JENDL-2 library. We confirm that the ratios of calculated and experimental (C/E) values using the JENDL-3.2 library are slightly better than those based on the JENDL-2 library. (author)

  11. Dosimetry; La dosimetrie

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  12. Estimation of covariances of {sup 16}O, {sup 23}Na, Fe, {sup 235}U, {sup 238}U and {sup 239}Pu neutron nuclear data in JENDL-3.2

    Shibata, Keiichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakajima, Yutaka; Kawano, Toshihiko; Oh, Soo-Youl; Matsunobu, Hiroyuki; Murata, Toru

    1997-10-01

    Covariances of nuclear data have been estimated for 6 nuclides contained in JENDL-3.2. The nuclides considered are {sup 16}O, {sup 23}Na, Fe, {sup 235}U, {sup 238}U, and {sup 239}Pu, which are regarded as important for the nuclear design study of fast reactors. The physical quantities for which covariances are deduced are cross sections, resolved and unresolved resonance parameters, and the first order Legendre-polynomial coefficient for the angular distribution of elastically scattered neutrons. As for {sup 235}U, covariances were obtained also for the average number of neutrons emitted in fission. The covariances were estimated by using the same methodology that had been used in the JENDL-3.2 evaluation in order to keep a consistency between mean values and their covariances. The least-squares fitting code GMA was used in estimating covariances for reactions of which JENDL-3.2 cross sections had been evaluated by taking account of measurements. In nuclear model calculations, the covariances were calculated by the KALMAN system. The covariance data obtained were compiled in the ENDF-6 format, and will be put into the JENDL-3.2 Covariance File which is one of JENDL special purpose files. (author). 193 refs.

  13. Toward JENDL-3.3: comments on the problems of JENDL-3.2 for the next version developments

    Hasegawa, Akira [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    Revision work for JENDL-3.2 is foreseen and the discussions about the problems of JENDL-3.2 is under going in a small advisory group of JNDC (Japanese Nuclear Data Committee) since this April. In this article main discussion points in that group are presented. Problems from evaluators` point of view, problem from users` point of view and request from anticipated users are summarized. Some discussions on U-235 cross sections in the thermal and epi-thermal energy range are made in relation of the new evaluation of resolved resonance parameters performed by Leal/Derrien. (author)

  14. Analysis of Doppler effect measurement in FCA cores using JENDL-3.2 library

    Okajima, Shigeaki

    1996-01-01

    For the evaluation of the calculation accuracy of the 238 U Doppler effect using JENDL-3.2 library, the previously measured Doppler reactivity worths in the FCA were systematically analyzed. In the analysis the Doppler reactivity worth was calculated by a first order perturbation theory. The calculated results were compared with those using JENDL-3.1 library. The JENDL-3.2 calculation in MOX fuel mock-up cores agrees well with the experimental values within the experimental error. In U-235/Pu fuel cores, the JENDL-3.2 calculation gives 12-15% larger Doppler reactivity worths than the JENDL-3.1 calculation. (author)

  15. Integral data testing of JENDL-3.2 for fusion reactor and shielding applications

    Oyama, Yukio

    1995-01-01

    Integral data testing of JENDL-3.2 is being performed in the activities of two working groups of the Japanese Nuclear Data Committee. The continuous and group-wise libraries prepared from JENDL-3.2 are planned to be tested by the working groups. In this paper, the continuous library FSXLIB-J3R2 processed from JENDL-3.2 for MCNP was tested for fission and fusion neutrons using data of integral experiments and compared to the results of JENDL-3.1. The results of integral data testing of JENDL-3.2 for fusion and shielding application are reviewed. (author)

  16. Self-shielding effect in unresolved resonance data in JENDL-4.0

    Konno, Chikara; Takakura, Kosuke; Ochiai, Kentaro; Sato, Satoshi; Kato, Yoshinari

    2012-01-01

    At International Conference on Nuclear Data for Science and Technology in 2007 we pointed out that most of unresolved resonance data in JENDL-3.3 have a problem related to self-shielding correction. Here with a simple calculation model we have investigated whether the latest JENDL, JENDL-4.0, was improved for the problem or not. The results suggest that unresolved resonance data in JENDL-4.0 have no problem, but it seems that self-shielding effects for the unresolved resonance data in JENDL-4.0 are too large. New benchmark experiments for unresolved resonance data are strongly recommended in order to verify unresolved resonance data. (author)

  17. New nuclear data group constant sets for fusion reactor nuclear analyses based on JENDL-4.0 and FENDL-3.0

    Konno, Chikara; Ohta, Masayuki; Kwon, Saerom; Ochiai, Kentaro; Sato, Satoshi

    2015-01-01

    We have produced new nuclear data group constant sets from JENDL-4.0 and FENDL-3.0 for fusion reactor nuclear analyses; FUSION-J40-175, FUSION-F30-175 (40 materials, neutron 175 groups, gamma 42 groups), FUSION-J40-42 and FUSION-F30-42 (40 materials, neutron 42 groups, gamma 21 groups). MATXS files of JENDL-4.0 and FENDL-3.0 were newly produced with the NJOY2012 code. FUSION-J40-175, FUSION-J40-42, FUSION-F30-175 and FUSION-F30-42 were produced with the TRANSX code. KERMA factors, DPA and gas production cross-section data were also prepared from the MATXS files with TRANSX. Test calculations were carried out in order to validate these nuclear group constant sets. They suggested that these group constant sets had no problem. (author)

  18. The JENDL-3 sublibrary for gas production. Summary of contents

    Nakagawa, T.; Narita, T.

    1993-01-01

    This document summarizes the contents of the JENDL-3 Sublibrary for Gas Production. This nuclear data library contains neutron-induced production cross-sections of hydrogen and helium nuclei for elements from 3-Li to 41-Nb. The library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section upon request. (author)

  19. Detailed benchmark test of JENDL-4.0 iron data for fusion applications

    Konno, Chikara, E-mail: konno.chikara@jaea.go.jp [Japan Atomic Energy Agency, Tokai-Mura, Ibaraki-ken, 319-1195 (Japan); Wada, Masayuki [Japan Computer System, Mito, 310-0805 (Japan); Kondo, Keitaro; Ohnishi, Seiki; Takakura, Kosuke; Ochiai, Kentaro; Sato, Satoshi [Japan Atomic Energy Agency, Tokai-Mura, Ibaraki-ken, 319-1195 (Japan)

    2011-10-15

    The major revised version of Japanese Evaluated Nuclear Data Library (JENDL), JENDL-4.0, was released in May, 2010. As one of benchmark tests, we have carried out a benchmark test of JENDL-4.0 iron data, which are very important for radiation shielding in fusion reactors, by analyzing the iron fusion neutronics integral experiments (in situ and Time-of-Flight (TOF) experiments) at JAEA/FNS. It is demonstrated that the problems of the iron data in the previous version of JENDL, JENDL-3.3, are solved in JENDL-4.0; the first inelastic scattering cross section data of {sup 57}Fe and the angular distribution of the elastic scattering of {sup 56}Fe. The iron data in JENDL-4.0 are comparable to or are partly better than those in ENDF/B-VII.0 and JEFF-3.1.

  20. Evaluation of covariances for resolved resonance parameters of 235U, 238U, and 239Pu in JENDL-3.2

    Kawano, Toshihiko; Shibata, Keiichi

    2003-02-01

    Evaluation of covariances for resolved resonance parameters of 235 U, 238 U, and 239 Pu was carried out. Although a large number of resolved resonances are observed for major actinides, uncertainties in averaged cross sections are more important than those in resonance parameters in reactor calculations. We developed a simple method which derives a covariance matrix for the resolved resonance parameters from uncertainties in the averaged cross sections. The method was adopted to evaluate the covariance data for some important actinides, and the results were compiled in the JENDL-3.2 covariance file. (author)

  1. Critical and subcritical mass calculations of curium-243 to -247 based on JENDL-3.2 for revision of ANSI/ANS-8.15

    Okuno, Hiroshi

    2002-01-01

    Critical and subcritical masses were calculated for a sphere of five curium isotopes from 243 Cm to 247 Cm in metal and in metal-water mixtures considering three reflector conditions: bare, with a water reflector or a stainless steel reflector. The calculation were made mainly with a combination of a continuous energy Monte Carlo neutron transport calculation code, MCNP, and the Japanese Evaluated Nuclear Data Library, JENDL-3.2. Other evaluated nuclear data files, ENDF/B-VI and JEF-2.2, were also applied to find differences in calculation results of the neutron multiplication factor originated from different nuclear data files. A large dependence on the evaluated nuclear data files was found in the calculation results: more than 10%Δk/k relative differences in the neutron multiplication factor for a homogeneous mixture of 243 Cm metal and water when JENDL-3.2 was replaced with ENDF/B-VI and JEF-2.2, respectively; and a 44% reduction in the critical mass by changing from JENDL-3.2 to ENDF/B-VI for 246 Cm metal. The present study supplied basic information to the ANSI/ANS-8.15 Working Group for revision of the standard for nuclear criticality control of special actinide elements. The new or revised values of the subcritical mass limits for curium isotopes accepted by the ANSI/ANS-8.15 Working Group were finally summarized. (author)

  2. Critical and subcritical mass calculations of curium-243 to -247 based on JENDL-3.2 for revision of ANSI/ANS-8.15

    Okuno, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kawasaki, Hiromitsu [CRC Solutions Corporation, Hitachinaka, Ibaraki (Japan)

    2002-10-01

    Critical and subcritical masses were calculated for a sphere of five curium isotopes from {sup 243}Cm to {sup 247}Cm in metal and in metal-water mixtures considering three reflector conditions: bare, with a water reflector or a stainless steel reflector. The calculation were made mainly with a combination of a continuous energy Monte Carlo neutron transport calculation code, MCNP, and the Japanese Evaluated Nuclear Data Library, JENDL-3.2. Other evaluated nuclear data files, ENDF/B-VI and JEF-2.2, were also applied to find differences in calculation results of the neutron multiplication factor originated from different nuclear data files. A large dependence on the evaluated nuclear data files was found in the calculation results: more than 10%{delta}k/k relative differences in the neutron multiplication factor for a homogeneous mixture of {sup 243}Cm metal and water when JENDL-3.2 was replaced with ENDF/B-VI and JEF-2.2, respectively; and a 44% reduction in the critical mass by changing from JENDL-3.2 to ENDF/B-VI for {sup 246}Cm metal. The present study supplied basic information to the ANSI/ANS-8.15 Working Group for revision of the standard for nuclear criticality control of special actinide elements. The new or revised values of the subcritical mass limits for curium isotopes accepted by the ANSI/ANS-8.15 Working Group were finally summarized. (author)

  3. Summary Report of Consultants' Meeting on Improvements and Extensions to IRDF (International Reactor Dosimetry File (IRDF-2002))

    Kellett, M.A.; Greenwood, L.R.

    2010-12-01

    The main aim of this Consultants' Meeting was to discuss the appropriate manner for implementing improvements and extensions to the current IRDF-2002 reactor dosimetry library. It was important to assess the applications requiring a dosimetry library, to discuss if a library that would meet the requirements of these varied applications could be produced and, if so, to define an approach for producing such an updated version. This report summarises the presentations and discussions undertaken in order to achieve these goals, followed by the recommendations and conclusions resulting from the meeting. (author)

  4. Jendl-3.1 iron validation on the PCA-REPLICA (H2O/Fe) shielding benchmark experiment

    Pescarini, M.; Borgia, M. G.

    1997-03-01

    The PCA-REPLICA (H 2 O/Fe) neutron shielding benchmarks experiment is analysed using the SN 2-D DOT 3.5-E code and the 3-D-equivalent flux synthesis method. This engineering benchmark reproduces the ex-core radial geometry of a PWR, including a mild steel reactor pressure vessel (RPV) simulator, and is designed to test the accuracy of the calculation of the in-vessel neutron exposure parameters. This accuracy is strongly dependent on the quality of the iron neutron cross sections used to describe the nuclear reactions within the RPV simulator. In particular, in this report, the cross sections based on the JENDL-3.1 iron data files are tested, through a comparison of the calculated integral and spectral results with the corresponding experimental data. In addition, the present results are compared, on the same benchmark experiment, with those of a preceding ENEA-Bologna validation of the ENDF/B VI iron cross sections. The integral result comparison indicates that, for all the threshold detectors considered (Rh-103 (n, n') Rh-103m, In-115 (n, n') In-115m and S-32 (n, p) P-32), the JENDL-3.1 natural iron data produce satisfactory results similar to those obtained with the ENDF/B VI iron data. On the contrary, when the JENDL/3.1 Fe-56 data file is used, strongly underestimated results are obtained for the lower energy threshold detectors, Rh-103 and In-115. This fact, in particular, becomes more evident with increasing the neutron penetration depth in the RPV simulator

  5. Computational analysis of Bangladesh 3 MW TRIGA research reactor using MCNP4C, JENDL-3.3 and ENDF/B-Vl data libraries

    Huda, M.Q.

    2006-01-01

    The three-dimensional continuous energy Monte Carlo code MCNP4C was used to develop a versatile and accurate full-core model of the 3 MW TRIGA MARK II research reactor at Atomic Energy Research Establishment, Savar, Dhaka, Bangladesh. The model represents in detail all components of the core with literally no physical approximation. All fresh fuel and control elements as well as the vicinity of the core were precisely described. Validation of the JENDL-3.3 and ENDF/BVI continuous energy cross-section data for MCNP4C was performed against some well-known benchmark lattices. For TRIGA analysis, data from JENDL-3.3 and ENDF/B-VI in combination with the JENDL-3.2 and ENDF/B-V data files (for nat Zr, nat Mo, nat Cr, nat Fe, nat Ni, nat Si, and nat Mg) at 300 K evaluations were used. Full S(α, β) scattering functions from ENDF/B-V for Zr in ZrH, H in ZrH and water molecule, and for graphite were used in both cases. The validation of the model was performed against the criticality and reactivity benchmark experiments of the TRIGA reactor. There is ∼20.0% decrease of thermal neutron flux occurs when the thermal library is removed during the calculation. Effect of erbium isotope that is present in the TRIGA fuel was also studied. In addition to the effective multiplication values, the well-known integral parameters: δ 28 , δ 25 , ρ 25 , and C * were calculated and compared for both JENDL3.3 and ENDF/B-VI libraries and were found to be in very good agreement. Results are also reported for most of the analyses performed by JENDL-3.2 and ENDF/B-V data libraries

  6. Evaluations of the 58Fe(n,γ)59Fe, and 54Fe(n,p)54Mn reactions for the ENDF/B-V dosimetry file

    Schenter, R.E.; Schmittroth, F.; Mann, F.M.

    1979-10-01

    A generalized least-squares adjustment procedure was used to evaluate two important dosimetry reactions for the ENDF/B-V files. Calculations for the cross section adjustments were made with the computer code FERRET, where input data included both integral and differential experimental data results. For the 54 Fe reaction, important ratio measurements were renormalized to ENDF/B-V evaluations of 235 U(n,f), 238 U(n,f), and 56 Fe(n,p). A priori curves which are required for the calculations were obtained using Hauser-Feshbach calculations from the codes NCAP ( 58 Fe) and HAUSER-5 ( 54 Fe). Covariance matrices were also calculated and are included in the evaluations. 8 figures, 1 table

  7. Evaluation of the 115In(n,n)/sup 115m/In reaction for the ENDF/B-V dosimetry file

    Smith, D.L.

    1976-12-01

    An evaluation of the 115 In(n,n')/sup 115m/In reaction for the ENDF/B-V Dosimetry File is presented. This evaluation is based entirely on reported experimental differential data. Several data sets were renormalized prior to the evaluation in order to take into account recent adjustments in corresponding standard cross sections and in other nuclear parameters used for derivation of cross sections. The present evaluation is compared with the corresponding ENDF/B-IV evaluation. The value of the spectrum-average cross section for the standard neutron field resulting from thermal-neutron fission of 235 U has been computed for this reaction using cross section values from the present evaluation. This computed cross section compares favorably with the result of a recent evaluation of integral data

  8. Revision of heavy nuclei data in JENDL-3.2

    Kawano, Toshihiko [Kyushu Univ., Advanced Energy Engineering Science, Kasuga, Fukuoka (Japan)

    2000-03-01

    In order to deal with problems concerning the data of heavy nuclides in JENDL-3.2, a working group was organized to update the evaluated nuclear data of Uranium, Plutonium, and Thorium isotopes. The current status of the working group is reviewed, and some results about resonance parameters, secondary neutron energy spectra, fission cross sections, and direct/semidirect capture process are shown. (author)

  9. Revision of heavy nuclei data in JENDL-3.2

    Kawano, Toshihiko

    2000-01-01

    In order to deal with problems concerning the data of heavy nuclides in JENDL-3.2, a working group was organized to update the evaluated nuclear data of Uranium, Plutonium, and Thorium isotopes. The current status of the working group is reviewed, and some results about resonance parameters, secondary neutron energy spectra, fission cross sections, and direct/semidirect capture process are shown. (author)

  10. Analysis of MISTRAL experiments with JENDL-3.2

    Umano, Takuya; Yamamoto, Toru; Kanda, Ryoji; Sasagawa, Masaru; Kan, Taro; Ishii, Kazuya; Ando, Yoshihira; Tatsumi, Masahiro

    2003-01-01

    NUPEC and CEA have launched and extensive experimental program called MISTRAL to study highly moderated MOX cores for the advanced LWRs. The analyses using the SRAC system and the MVP code with the JENDL-3.2 library are in progress on the experiments of the MISTRAL program and also the EPICURE program that was carried out by CEA before the MISTRAL program. Various comparisons have been made between the calculation results and the measurement values. (author)

  11. Integral test of JENDL-3.3 for fast reactors

    Chiba, Gou

    2003-01-01

    An integral test of JENDL-3.3 was performed for fast reactors. Various types of fast reactors were analyzed. Calculation values of the nuclear characteristics were greatly especially affected by the revisions of the cross sections of U-235 capture and elastic scattering reactions. The C/E values were improved for ZPPR cross where plutonium is mainly fueled, but not for BFS cores where uranium is mainly fueled. (author)

  12. Analysis of the MOZART experiments with JENDL-1

    Seki, Yuji; Hojuyama, Takeshi

    1979-01-01

    Analyses of the MOZART experiments have been made on reaction rate distributions, sodium void reactivity map and control rod worths to confirm the applicability of JENDL-1 to fast reactor core design. Some anomalous C/E-values have been observed in these core parameters at the outer core and the blanket. Further study is needed in both nuclear data evaluation and data processing method. (author)

  13. Japanese evaluated nuclear data library version 3 revision-3: JENDL-3.3

    Shibata, K; Kawano, T

    2002-01-01

    Evaluation for JENDL-3.3 has been performed by considering the accumulated feedback information and various benchmark tests of the previous library JENDL-3.2. The major problems of the JENDL-3.2 data were solved by the new library: overestimation of criticality values for thermal fission reactors was improved by the modifications of fission cross sections and fission neutron spectra for sup 2 sup 3 sup 5 U; incorrect energy distributions of secondary neutrons from important heavy nuclides were replaced with statistical model calculations; the inconsistency between elemental and isotopic evaluations was removed for medium-heavy nuclides. Moreover, covariance data were provided for 20 nuclides. The reliability of JENDL-3.3 was investigated by the benchmark analyses on reactor and shielding performances. The results of the analyses indicate that JENDL-3.3 predicts various reactor and shielding characteristics better than JENDL-3.2. (author)

  14. MCNP and MATXS cross section libraries based on JENDL-3.3

    Kosako, Kazuaki; Konno, Chikara; Fukahori, Tokio; Shibata, Keiichi

    2003-01-01

    The continuous energy cross section library for the Monte Carlo transport code MCNP-4C, FSXLIB-J33, has been generated from the latest version of JENDL-3.3. The multigroup cross section library with the MATXS format, MATXS-J33, has been generated also from JENDL-3.3. Both libraries contain all nuclides in JENDL-3.3 and are processed at 300 K by the nuclear data processing system NJOY99. (author)

  15. Summary Report of the 1. Research Coordination Meeting on Testing and Improving the International Reactor Dosimetry and Fusion File (IRDFF)

    Trkov, A.; Greenwood, L.R.; Simakov, S.P.

    2013-09-01

    In accordance with the recommendations of the International Nuclear Data Committee in May 2012, the Nuclear Data Section of IAEA has initiated a new Coordinated Research Project (CRP number F41031) with the main goal to test, validate and improve the international dosimetry library for fission and fusion (IRDFF). The output of this CRP will be a reference dosimetry database of cross sections and decay data with corresponding documentation. It will serve to the needs of fission, fusion and accelerator applications. The first Research Coordination Meeting (RCM) was held 1 to 5 July 2013 in IAEA. At this meeting, the attendees discussed the objectives of the whole CRP, presented their contributions and elaborated on consolidated recommendations and actions for implementation over the next 1.5 year period. This Summary Report documents the individual contributions and joint decisions made during this meeting. (author)

  16. FAIR-DDX, Double Diffusion Cross-Sections Scattering Matrix Generated from ENDF/B-4 or JENDL-2

    Minami, Kazuyoshi; Yamano, Naoki

    2001-01-01

    1 - Description of program or function: FAIR-DDX produces double differential (energy and angle) cross sections (DDX) in the form of group-to-group scattering matrices using the evaluated nuclear data libraries JENDL-2 or ENDF/B-IV. The DDX form is useful for verification of the evaluated data, such as the inelastic scattering, through comparison with the experimental DDX values. 2 - Method of solution: DDX uses the file 4 data (angular distribution of secondary neutrons) and the energy and momentum conservation laws. For continuum region reactions, file 5 (energy spectrum of secondary neutrons) is used. To express the angular distribution of secondary neutrons in group-to-group scattering matrices FAIR-DDX adopts a direct angular representation method. 3 - Restrictions on the complexity of the problem: The maximum number of energy groups is 200

  17. Sensitivity analysis for reactivity parameter change of the creole experiment caused by the differences between ENDF-BVII and JENDL neutron cross section evaluations

    Boulaich, Y.; Bardouni, C.; Elyounoussi, C.; Elbakkari, H.; Boukhal, H.; Erradi, L.; Nacir, B.

    2011-01-01

    Full text: In this work, we present our analysis of the CREOLE experiment on the parameter by using the three-dimensional continuous energy code (MCNPS) and the last updated nuclear data evaluations. This experiment performed in the EOLE critical facility located at CEA-Cadarache, was dedicated to studies for both UO2 and UO2-PuO2 PWR type lattices covering the whole temperature range from 20 0 C to 300 0 C. We have developed an accurate model of the EOLE reactor to be used by the MCNP5 Monte Carlo code. This model guarantees a high level of fidelity in the description of different configurations at various temperatures taking into account their consequence on neutron cross section data and all thermal expansion effects. In this case, the remaining error between calculation and experiment will be awarded mainly to uncertainties on nuclear data. Our own cross section library was constructed by using NJOY99.259 code with point-wise nuclear data based on ENDF-BVII. JEFF3.1, JENDL3.3 and JENDL4 evaluation files. The MCNP model was validated through the axial and radial fission rate measurements at room and hot temperatures. Calculation-experiment discrepancies of the reactivity parameter were analyzed and the results have shown that the JENDL evaluations give the most consistent values. In order to specify the source of the relatively large difference between experiment and calculation due to ENDF-BVII nuclear data evaluation, the discrepancy in reactivity between ENDF-BVII and JENDL evaluations was decomposed using sensitivity and uncertainty analysis technique

  18. Present status and benchmark tests of JENDL-2

    Kikuchi, Y.

    1983-01-01

    The second version of Japanese Evaluated Nuclear Data Library (JENDL-2) consists of the evaluated data from 10 -5 eV to 20 MeV for 176 nuclides including 99 fission product nuclei. Complete reevaluation has been made to heavy actinide, fission product and main structural material nuclides. Benchmark tests have been made on JENDL-2 for fast reactor application. Various characteristics in core center have been tested with one-dimensional model for total of 27 assemblies, and more sophisticated problems have been examined for MOZART and ZPPR-3. Furthermore analyses of JUPITER project give useful information. Satisfactory results have been obtained as a whole. However, the spectrum is a little underestimated above a few hundred keV and below a few keV. The positive sodium void reactivity worth is much overestimated. As to the latter, the sensitivity analysis with the generalized perturbation method suggests that the fission cross section of 239 Pu below a few keV has an important role. (Auth.)

  19. Integral test of JENDL-3.3 on fast reactors

    Chiba, Gou; Hazama, Taira

    2003-05-01

    An integral test has been carried out to evaluate a performance of evaluated nuclear data library JENDL-3.3, which was newly released, in a view of applying neutronics analyses of fast reactors. Japan Nuclear Cycle Development Institute has a large amount of data of critical assembly experiments (ZPPR, BFS, MOZART and FCA) and power reactor tests (JOYO). The database was utilized in this test. In plutonium loaded cores, an improvement was observed about 0.3% ε k in criticality and 5% in the non-leakage term of sodium void reactivity by a revision form JENDL-3.2 to -3.3. These results shoed that the revision is valid in plutonium loaded cores. In uranium loaded cores, dependence of C/E values on control rod position became smaller in control rod worth in ZPPR cores. On the other hand, C/E values became worse both in criticality (0.6%εk) and in sodium void reactivity (30%) in BFS cores. The main cause was a revision of uranium-235 capture cross section, and it could not be concluded whether the revision is valid or not in uranium loaded cores. It is necessary to carry out a validation test at other independent critical experiments in which uranium fuel is used. (author)

  20. 3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry.

    Barbeiro, A R; Ureba, A; Baeza, J A; Linares, R; Perucha, M; Jiménez-Ortega, E; Velázquez, S; Mateos, J C; Leal, A

    2016-01-01

    A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from the high spatial resolution of films hosted in QuAArC. This cylindrical phantom was specifically designed to host films rolled at different radial distances able to take into account the entrance fluence and the 3D dose distribution. Ionization chamber measurements are also included in the feedback process for absolute dose considerations. In this way, automated MC simulation of treatment log files is implemented to calculate the actual delivery geometries, while the monitor units are experimentally adjusted to reconstruct the dose-volume histogram (DVH) on the patient CT. Prostate and head and neck clinical cases, previously planned with Monaco and Pinnacle treatment planning systems and verified with two different commercial systems (Delta4 and COMPASS), were selected in order to test operational feasibility of the proposed model. The proper operation of the feedback procedure was proved through the achieved high agreement between reconstructed dose distributions and the film measurements (global gamma passing rates > 90% for the 2%/2 mm criteria). The necessary discretization level of the log file for dose calculation and the potential mismatching between calculated control points and detection grid in the verification process were discussed. Besides the effect of dose calculation accuracy of the analytic algorithm implemented in treatment planning systems for a dynamic technique, it was discussed the importance of the detection density level and its location in VMAT specific phantom to obtain a more reliable DVH in the patient CT. The proposed model also showed enough robustness and efficiency to be considered as a pre

  1. Dosimetry Service

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  2. Jendl-3.1 iron validation on the PCA-REPLICA (H{sub 2}O/Fe) shielding benchmark experiment

    Pescarini, M.; Borgia, M. G. [ENEA, Centro Ricerche ``Ezio Clementel``, Bologna (Italy). Dipt. Energia

    1997-03-01

    The PCA-REPLICA (H{sub 2}O/Fe) neutron shielding benchmarks experiment is analysed using the SN 2-D DOT 3.5-E code and the 3-D-equivalent flux synthesis method. This engineering benchmark reproduces the ex-core radial geometry of a PWR, including a mild steel reactor pressure vessel (RPV) simulator, and is designed to test the accuracy of the calculation of the in-vessel neutron exposure parameters. This accuracy is strongly dependent on the quality of the iron neutron cross sections used to describe the nuclear reactions within the RPV simulator. In particular, in this report, the cross sections based on the JENDL-3.1 iron data files are tested, through a comparison of the calculated integral and spectral results with the corresponding experimental data. In addition, the present results are compared, on the same benchmark experiment, with those of a preceding ENEA-Bologna validation of the ENDF/B VI iron cross sections. The integral result comparison indicates that, for all the threshold detectors considered (Rh-103 (n, n`) Rh-103m, In-115 (n, n`) In-115m and S-32 (n, p) P-32), the JENDL-3.1 natural iron data produce satisfactory results similar to those obtained with the ENDF/B VI iron data. On the contrary, when the JENDL/3.1 Fe-56 data file is used, strongly underestimated results are obtained for the lower energy threshold detectors, Rh-103 and In-115. This fact, in particular, becomes more evident with increasing the neutron penetration depth in the RPV simulator.

  3. Benchmark test of JENDL-3T and -3T/Rev.1

    Takano, Hideki; Kaneko, Kunio.

    1989-10-01

    The fast reactor 70-group constant set JFS-3-J3T has been generated by using the JENDL-3T nuclear data. One-dimensional 21-benchmark cores and the ZPPR-9 core were analysed with the JFS-3-J3T set. The results obtained are summarized as follows: (1) The values of keff are underestimated by 0.6% for Pu-fueled cores and overestimated by 2% for U-fueled cores. (2) The central reaction rate ratio 239 σ f φ/ 235 σ f φ is in a good agreement with the experimental value, though 238 σ c φ/ 239 σ f φ and 238 σ f φ/ 235 σ f φ are overestimated. (3) Doppler and Na-void reactivities are in a good agreement with the measured data. (4) The prediction accuracy of radial reaction rate distributions are improved in the comparison of the results obtained with the JENDL-2 data. Furthermore, the benchmark test of JENDL-3T/Rev. 1 which was revised from JENDL-3T for several important nuclides has been again performed. It was shown that JENDL-3T/Rev. 1 would predict nuclear characteristics more satisfactorily than JENDL-3T. (author)

  4. Calibration of a He accumulation fluence monitor for fast reactor dosimetry

    Ito, Chikara [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    The helium accumulation fluence monitor (HAFM) has been developed for a fast reactor dosimetry. The HAFM measurement system was calibrated using He gas and He implanted samples and the measurement accuracy was confirmed to be less than 5%. Based on the preliminary irradiation test in JOYO, the measured He in the {sup 10}B type HAFM agreed well with the calculated values using the JENDL-3.2 library. (author)

  5. Differences among KERMA or DPA data calculated from JENDL-4.0, ENDF/B-VII.1, JEFF-3.2 and FENDL-3.1b with NJOY

    Konno, C.

    2016-01-01

    KERMA factors and DPA cross-section data below 20 MeV in the official ACE files of JENDL-4.0, ENDF/B-VII.1, JEFF-3.2 and FENDL-3.1b were compared in detail. As a result, it was found out that the KERMA and DPA data of a lot of nuclei were different among the nuclear data libraries. Reasons of most of the differences were successfully categorized to the nuclear data and NJOY issues. The KERMA factors and DPA cross-section data in the ACE files with the problems should be revised. (author)

  6. Evaluation of Some (n,n'), (n,γ), (n,p), (n,2n) and (n,3n) Reaction Excitation Functions for Fission and Fusion Reactor Dosimetry Applications; Evaluation of the Excitation Functions for the 54Fe(n,p)54Mn, 58Ni(n,2n)57Ni, 67Zn(n,p)67Cu, 92Mo(n,p)92mNb, 93Nb(n,γ)94Nb, 113In(n,n')113mIn, 115In(n,γ) 116mIn, and 169Tm(n,3n)167Tm Reactions. Progress Report on Research Contract No 16242

    Zolotarev, K.I.; Zolotarev, P.K.

    2013-12-01

    Cross section data for the 54 Fe(n,p) 54 Mn, 58 Ni(n,2n) 57 Ni, 67 Zn(n,p) 67 Cu, 92 Mo(n,p) 92m Nb, 93 Nb(n,γ) 94 Nb, 113 In(n,n') 113m In, 115 In(n,γ) 116m In, 169 Tm(n,3n) 167 Tm reactions are needed to solve a wide spectrum of scientific and technical tasks. Activation detectors based on these reactions may be used in the field of reactor dosimetry. Furthermore, the 54 Fe(n,p) 54 Mn reaction is often used in experimental nuclear physics as a monitor reaction for measurements of unknown cross sections by means of the activation method over the neutron energy range from 5 to 15 MeV. The 93 Nb(n,γ) 94 Nb reaction is also very promising for using in retrospective neutron dosimetry for determination of total neutron fluence during a campaign of a reactor. In the existing version of the International Reactor Dosimetry File and the new extended version named as IRDFF data for excitation functions of 67 Zn(n,p) 67 Cu, 92 Mo(n,p) 92m Nb, 113 In(n,n') 113m In, and 169 Tm(n,3n) 167 Tm reactions are absent. Data for these reactions are also absent in the JENDL/D-99 dosimetry file. Excitation functions of 67 Zn(n,p) 67 Cu and 169 Tm(n,3n) 167 Tm are presented in the TENDL-2012, EAF-2010, JENDL-4.0, JEFF-3.1/A, MENDL-2 libraries. Cross section data for the 67 Zn(n,p) 67 Cu reaction up to 20 MeV are given also in the JENDL/HE-2007 library. Excitation functions of the 92 Mo(n,p) 92m Nb and 113 In(n,n') 113m In reactions are evaluated in the EAF-2010 and JEFF-3.1/A libraries. Cross section data for the 113 In(n,n') 113m In reaction are given also in the TENDL-2010 library. It is necessary to note that neutron data in the JEFF-3.1/A and JENDL-4.0 libraries were evaluated up to 20 MeV. Neutron data in the TENDL-2012, EAF-2010, MENDL-2 and TENDL-2010 libraries had been evaluated up to 30 MeV, 60 MeV, 100 MeV and 200 MeV, respectively. Neutron cross sections in the MENDL-2, TENDL-2010 and TENDL-2012 libraries had been obtained on the basis of pure theoretical model calculations

  7. ESR Dosimetry

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  8. Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  9. Dosimetry Service

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  10. Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  11. Activity report of Japanese Nuclear Data Committee in period of April 1997 to March 1999

    1999-01-01

    This report presents the activities of the Japanese Nuclear Data Committee (JNDC) in the period of April 1997 to March 1999. In this period, preparation of the next version of the Japanese Evaluated Nuclear Data Library, JENDL-3.3, has progressed. Generation of the special purpose files also has been advanced. In this report, the activities of each group affiliated by the committee are presented and the following are described as special topics : (1) progress in evaluating JENDL-3.3, (2) production of JENDL Covariance File and its processing system, (3) completion of the JENDL Dosimetry File, and (4) the JENDL FP Decay Data File. (author)

  12. Analysis of benchmark lattices with endf/b-vi, jef-2.2 and jendl-3 data

    Saglam, M.

    1995-01-01

    The NJOY Nuclear Data Processing System has been used to process the ENDF/B-VI , JEF-2.2 and JENDL-3 Nuclear Cross Section Data Bases into multigroup form. A brief description of the data bases is given and the assumptions made in processing the data from evaluated nuclear data file format to multigroup format are presented. The differences and similarities of the Evaluated Nuclear Data Files have been investigated by producing four group cross sections by using the GROUPIE code and calculating thermal, fission spectrum averaged and 2200 m/s cross sections and resonance integrals using the INTER cale. It has been shown that the evaluated data for U238 in JEF and ENDF/B-VI are principally the same while in case of U235 the same is true for JENDL and ENDF/B-VI. The evaluations for U233 and Th232 are different for all three ENDF files. Several utility codes have been written to convert the multigroup library into a WIMS-D4 compatible binary library. The performance and suitability of the generated libraries have been tested with the use of metal tueled TRX lattices, uranium oxide fueled BAPL lattices and Th232-U233 fueled BNL lattices. The use ot a new thermal scattering matrix for Hydrogen from ENDF/B-VI increased keff for 0.5 o/ while the use of ENDF/B-VI U238 decreased it for 2.5 %. Although the original WIMS library performed well for Ihe effective multiplication factor of the lattices there is an improvement for the epithermal to thermal capture rate of U238 while using new data in the TRX and BAPL lattices. The effect of the fission spectrum is investigated for the BNL lattices and it is shown that using U233 fission spectrum instead of the original U235 spectrum gives a keff which agrees better with the experimental value. The results obtained by using new multigroup data are generally acceptable and in the experimental error range. They especially improve the prediction of the reaction rate dependent benchmark parameters

  13. Benchmark comparisons of evaluated nuclear data files

    Resler, D.A.; Howerton, R.J.; White, R.M.

    1994-05-01

    With the availability and maturity of several evaluated nuclear data files, it is timely to compare the results of integral tests with calculations using these different files. We discuss here our progress in making integral benchmark tests of the following nuclear data files: ENDL-94, ENDF/B-V and -VI, JENDL-3, JEF-2, and BROND-2. The methods used to process these evaluated libraries in a consistent way into applications files for use in Monte Carlo calculations is presented. Using these libraries, we are calculating and comparing to experiment k eff for 68 fast critical assemblies of 233,235 U and 239 Pu with reflectors of various material and thickness

  14. Analyses of iron and concrete shielding experiments at JAEA/TIARA with JENDL/HE-2007, ENDF/B-VII.1 and FENDL-3.0

    Konno, Chikara; Ochiai, Kentaro; Sato, Satoshi; Ohta, Masayuki

    2015-01-01

    IAEA released a new Fusion Evaluated Nuclear Data Library, FENDL-3.0, in 2012. FENDL-3.0 extends the neutron energy range from 20 MeV to greater than 60 MeV. Now there is increasing interest in nuclear data above 20 MeV. Thus we have analyzed the iron and concrete shielding experiments with the 40 and 65 MeV neutron sources at TIARA in Japan Atomic Energy Agency with the latest high-energy nuclear data libraries, JENDL/HE-2007, ENDF/B-VII.1 and FENDL-3.0. The Monte Carlo code MCNP-5 and ACE files of JENDL/HE-2007, ENDF/B-VII.1 and FENDL-3.0, which are supplied from JAEA, LANL and IAEA, respectively, were used for this analysis. The collimated neutron beam and test shields were modeled in the analysis. The measured source neutron data were adopted in the analysis. The followings are found out from the results; (1) Iron experiments: The calculation result with FENDL-3.0 agrees with the measured one best. That with JENDL/HE-2007 fairly agrees with the measured one. On the contrary that with ENDF/B-VII.1 drastically overestimates the measured one. It is confirmed that this overestimation is due to the smaller non-elastic scattering data of "5"6Fe in ENDF/B-VII.1. (2) Concrete experiments: The calculation result with ENDL/HE-2007 agrees with the measured one best, while those with FENDL-3.0 and ENDF/B-VII.1 drastically overestimate the measured one. It is confirmed that this overestimation is due to both the larger elastic and smaller non-elastic scattering data of "1"6O in FENDL-3.0 and ENDF/B-VII.1.

  15. Analyses of criticality and reactivity for TRACY experiments based on JENDL-3.3 data library

    Sono, Hiroki; Miyoshi, Yoshinori; Nakajima, Ken

    2003-01-01

    The parameters on criticality and reactivity employed for computational simulations of the TRACY supercritical experiments were analyzed using a recently revised nuclear data library, JENDL-3.3. The parameters based on the JENDL-3.3 library were compared to those based on two former-used libraries, JENDL-3.2 and ENDF/B-VI. In the analyses computational codes, MVP, MCNP version 4C and TWOTRAN, were used. The following conclusions were obtained from the analyses: (1) The computational biases of the effective neutron multiplication factor attributable to the nuclear data libraries and to the computational codes do not depend the TRACY experimental conditions such as fuel conditions. (2) The fractional discrepancies in the kinetic parameters and coefficients of reactivity are within ∼5% between the three libraries. By comparison between calculations and measurements of the parameters, the JENDL-3.3 library is expected to give closer values to the measurements than the JENDL-3.2 and ENDF/B-VI libraries. (3) While the reactivity worth of transient rods expressed in the $ unit shows ∼5% discrepancy between the three libraries according to their respective β eff values, there is little discrepancy in that expressed in the Δk/k unit. (author)

  16. JENDL-4.0 benchmarking for effective delayed neutron fraction with a continuous-energy Monte Carlo code MVP

    Nagaya, Yasunobu

    2013-01-01

    Benchmark calculations with a continuous-energy Monte Carlo code have been performed for delayed neutron data of JENDL-4.0. JENDL-4.0 gives good prediction for the effective delayed neutron fraction in the present benchmarks but further detailed analysis is required for some cores. (author)

  17. Review of nuclear data of major actinides and 56Fe in JENDL-4.0

    Iwamoto, Osamu; Iwamoto, Nobuyuki

    2014-01-01

    JENDL-4.0 was released in 2010. Most of the actinide data were revised from JENDL-3.3, especially at the fast energy region, using the newly developed CCONE code. Fission cross-sections of major actinides were determined using the least-squares method and the SOK code, taking available experimental data into account. In the resonance region around 1 keV for 235 U, capture cross-sections were reduced to improve integral benchmark tests. The reduction was confirmed by Jandel, et al. during a later experiment at Los Alamos. For 56 Fe, cross-sections of inelastic scattering and angular distributions of elastic scattering were revised from JENDL-3.3. Evaluation methods and comparisons with experimental data and other evaluated data will be reviewed. (authors)

  18. Maxwellian-averaged cross sections calculated from JENDL-3.2

    Nakagawa, Tsuneo; Chiba, Satoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ohsaka, Toshiro; Igashira, Masayuki [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Tokyo (Japan)

    2000-02-01

    Maxwellian-averaged cross sections of neutron capture, fission, (n,p) and (n,{alpha}) reactions are calculated from the Japanese Evaluated Nuclear Data Library, JENDL-3.2, for applications in the astrophysics. The calculation was made in the temperature (kT) range from 1 keV to 1 MeV. Results are listed in tables. The Maxwellian-averaged capture cross sections were compared with recommendations of other authors and recent experimental data. Large discrepancies were found among them especially in the light mass nuclides. Since JENDL-3.2 reproduces relatively well the recent experimental data, we conclude that JENDL-3.2 is superior to the others in such a mass region. (author)

  19. JENDL reactor constant and its application. The 40th anniversary of Japan nuclear data committee

    Zukeran, Atsushi

    2004-01-01

    The status of reactor constants about 27 years ago is briefly reviewed from the criticality predictions and nuclear data processing codes. In the second section, status of current users of JENDL-3.3 and/or JENDL-3.2 is consulted with the 2003 Fall Meeting of Atomic Energy Society of Japan. In the third section, the reliabilities of JENDL-3.3 and -3.2 are reviewed mainly from the application to light water reactor (LWR) mockup experiments; MISTRAL and BASALA made on EOLE critical facility of Cadarache Laboratory in France, since an extensive evaluation for nuclear data applicability to LWR have been scarcely performed in relative to for FBR. The results of international benchmark cores and criticality safety analyses are briefly reviewed. In the concluding remarks, overall applicability is shown as a summary with respect to all reactor parameters obtained in the LWR mockup experiment and some remarks are noted. (author)

  20. Dosimetry methods

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  1. Evaluation of the fusion-related neutron nuclear data for JENDL-3

    Chiba, Satoshi

    1988-01-01

    Status of the neutron nuclear data evaluations for JENDL-3 will be described for nuclides important in the development of D-T fusion reactors. In this article, however, only explanation of the evaluations for the very light mass region will be presented to avoid overlapping with what are given in another papers submitted to this seminar. Emphases are placed on the tritium production cross sections, inelastic scattering cross sections including the double-differential neutron emission spectrum (DDX), threshold reaction cross sections and photon production cross sections. The methods employed to prepare JENDL-3T library and their results will be summarized. (author)

  2. CD-ROM storing JENDL-3.2 plots and data

    Fukahori, Tokio; Iwamoto, Osamu; Nakagawa, Tsuneo; Shibata, Keiichi; Narita, Tsutomu; Katakura, Jun-ichi; Hasegawa, Akira [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-01-01

    Numerical data and graphs of Japanese Evaluated Nuclear Data Library, Version 3, Revision 2 (JENDL-3.2) have been stored into CD-ROM. JENDL-3.2 is an evaluated nuclear data library which is highly rated in the world, and consists of neutron nuclear data and secondary gamma-ray data for 340 nuclides. JENDL-3.2 has been already released through World Wide Web (WWW, http://cracker.tokai.jaeri.go.jp). For users` convenience and to promote further utilization, this CD-ROM has been produced. The data stored in CD-ROM are the original data and point-wise data (0 K and 300 K) of JENDL-3.2 and graphs of cross sections in gif, PostScript and PDF formats. These data can be retrieved by users` personal computers and engineering workstations, and also can be seen by using WWW browsers. This CD-ROM makes user completely free from downloading, which takes a lot of time, and tedious management such a treating big amount of data. (author)

  3. Generation and validation of the WIMS-D5 library based on JENDL-3.2

    Gil, Choong-Sup; Kim, Jung-Do

    2002-01-01

    A WIMS-D5 library based on JENDL-3.2 has been prepared and is being tested against benchmark problems. Several sensitivity calculations for stability confirmation of the library were carried out, such as fission spectrum dependency and the self-shielding effects of the elastic scattering cross sections and the self-shielding effects 240 Pu and 242 Pu capture cross sections below 4.0 eV. The results of benchmark calculations with the libraries based on JENDL-3.2, ENDF/B-VI.5, JEF-2.2, and the 1986 WIMS-D library were intercompared. The multiplication factors for the thermal lattices are slightly underpredicted by all libraries (up to 1% with ENDF/B-VI.5). The k eff values with the library based on JENDL-3.2 are slightly higher than those of ENDF/B-VI.5 and JEF-2.2. The spectral indices for the lattices with JENDL-3.2 agree with the measured quantities within the uncertainties of the experiments. The calculated amounts of some isotopes such as 149 Sm, 237 Np, 238 Pu, 242 Cm and 243 Cm show large differences from the measured or reference values. (author)

  4. Neutron nuclear data evaluation of cesium isotopes for JENDL-4.0

    Iwamoto, Nobuyuki

    2011-01-01

    For the development of JENDL-4.0, neutron nuclear data for fission product nuclides, 133,134,135,136,137 Cs, were revised in the incident neutron energy range from 1 eV to 20 MeV by using a coupled-channels optical model (OM), and nuclear reaction models. The OM potential parameters were determined for stable 133 Cs to reproduce the experimental data of total and elastic scattering cross sections and angular distributions of elastically scattered neutrons. The present results reasonably reproduce measured data for (n,2n), (n,p), (n,α), and capture reactions on 133 Cs. Important differences between the present results and JENDL-3.3 are found for the capture cross sections of 134,137 Cs. The cross section obtained for 137 Cs was smaller than that in JENDL-3.3. This result makes the transmutation of medium-lived 137 Cs increasingly difficult. The production probabilities of metastable states for 134,138 Cs via capture reactions on 133,137 Cs are compared with experimental values. The present result for 134m Cs production is marginally consistent with measured data. However, a large discrepancy is recognized for 138m Cs production. The γ-ray emission data were evaluated with available measurements, and newly compiled in JENDL-4.0. Maxwellian-averaged capture cross sections were calculated in the energy range from 1 to 10 3 keV, and are compared with other derived data. (author)

  5. JENDL-4.0 benchmarking for effective delayed neutron fraction of fast neutron systems

    Chiba, Go; Tsuji, Masashi; Sugiyama, Ken-ichiro; Narabayashi, Tadashi

    2011-01-01

    The performance of the latest Japanese evaluated nuclear data library JENDL-4.0 for the prediction of effective delayed neutron fraction β eff is assessed using experimental data of a wide range of fast neutron systems. Covariance data of JENDL-4.0 are used to quantify nuclear-data-induced uncertainties. Calculations with other libraries. JENDL-3.3, ENDF/B-VII.0, and JEFF-3.1, are also carried out for a quantitative comparison. JENDL-4.0 results in good agreement between calculation and experimental values within total uncertainties, and consistency between the differential nuclear data and integral experimental data is confirmed. While the other libraries also show good performance for β eff prediction, there are small differences in the predicted values of β eff among different libraries and ENDF/B-VII.0 gives the most stable results. Furthermore, a simple and convenient procedure to calculate sensitivity profiles of β eff to nuclear data is proposed. (author)

  6. Development of libraries for ORIGEN2 code based on JENDL-3.2

    Suyama, Kenya; Katakura, Jun-ichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ishikawa, Makoto; Ohkawachi, Yasushi

    1998-03-01

    The working Group of JNDC `Nuclide Generation Evaluation` has launched a project to make libraries for ORIGEN2 code based on the latest nuclear data library `JENDL-3.2` for current design of LWR and FBR fuels. Many of these libraries are under validation. (author)

  7. Clinical dosimetry

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  8. Status of neutron cross sections for reactor dosimetry

    Vlasov, M.F.; Fabry, A.; McElroy, W.N.

    1977-03-01

    The status of current international efforts to develop standardized sets of evaluated energy-dependent (differential) neutron cross sections for reactor dosimetry is reviewed. The status and availability of differential data are considered, some recent results of the data testing of the ENDF/B-IV dosimetry file using 252 Cf and 235 U benchmark reference neutron fields are presented, and a brief review is given of the current efforts to characterize and identify dosimetry benchmark radiation fields

  9. Environmental dosimetry

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  10. ZZ ORIGEN2.2-UPJ, A complete package of ORIGEN2 libraries based on JENDL-3.2 and JENDL-3.3

    Ishikawa, Makoto; Kataoka, Masaharu; Ohkawachi, Yasushi; Ohki, Shigeo; JIN, Tomoyuki; Katakura, Jun-ich; Suyama, Kenya; Yanagisawa, Hiroshi; Matsumoto, Hideki; ONOUE, Akira; Sasahara, Akihiro

    2006-01-01

    1 - Description: ORLIBJ32 is a package of the libraries for ORIGEN2 code based on JENDL-3.2(NEA-1642). The one grouped cross section data for PWR and BWR were compiled using the burnup calculation results by SWAT code. The FBR libraries were compiled by the analysis system used at JNC for FBR core calculation. The fission yield and decay constants data were also updated using the second version of the JNDC FP library. In ORLIBJ32, not only one-grouped cross section data but also variable actinide cross section data are prepared, using a code written in FORTRAN77. The routines should be linked to the Original ORIGEN2.1 program. The LWR Libraries are prepared based on the current PWR fuel assembly specification, and the FBR libraries are based on the request by the Japanese FBR researchers. Before compiling the libraries, the specification of fuel assembly was completely reviewed and evaluated by the members of Working Group in the Japanese Nuclear Data Committee, 'working group on the evaluation of the amount of isotope generation'. ORLIBJ33 is a new libraries based on JENDL-3.3 following the release of JENDL-3.3. The parameters used to prepare the library are the same as those of ORLIBJ32. The Original version or ORLIBJ33 is coupled with ORIGEN2.1. But after the release of ORIGEN2.2 from ORNL as CCC-0371 through RSICC, several requests for a combination with ORLIBJ33 and ORIGEN2.2 were received. During the development of ORLIBJ33, released as NEA-1642, authors found a problem in the library maker for FBR libraries, and consequently it was revised and tested in JNC-Oarai. This package 'ORIGEN2.2-UPJ' contains: - updated source code of ORIGEN2.2 of CCC-0371 to use ORLIBJ32 and ORLIBJ33, - all Original libraries in CCC-0371, - ORLIBJ32 in NEA-164/03 (but libraries for FBR are revised), - and ORLIBJ33. In this package, decay data based on the second version of the JNDC FP library and, photon and decay data libraries based on JENDL-3.3 are also included. NLB and NLIB

  11. Compilation of MCNP data library based on JENDL-3T and test through analysis of benchmark experiment

    Sakurai, K.; Sasamoto, N.; Kosako, K.; Ishikawa, T.; Sato, O.; Oyama, Y.; Narita, H.; Maekawa, H.; Ueki, K.

    1989-01-01

    Based on an evaluated nuclear data library JENDL-3T, a temporary version of JENDL-3, a pointwise neutron cross section library for MCNP code is compiled which involves 39 nuclides from H-1 to Am-241 which are important for shielding calculations. Compilation is performed with the code system which consists of the nuclear data processing code NJOY-83 and library compilation code MACROS. Validity of the code system and reliability of the library are certified by analysing benchmark experiments. (author)

  12. Neutron personnel dosimetry

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  13. Individual dosimetry and calibration

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  14. Hematological dosimetry

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  15. ORIGEN-2 libraries based on JENDL-3.2 for PWR-MOX fuel

    Matsumoto, Hideki; Onoue, Masaaki; Tahara, Yoshihisa [Mitsubishi Heavy Industries Ltd., Tokyo (Japan)

    2001-08-01

    A set of ORIGEN-2 libraries for PWR MOX fuel was developed based on JENDL-3.2 in the Working Group on Evaluation of Nuclide Production, Japanese Nuclear Data Committee. The calculational model generating ORIGEN-2 libraries of PWR MOX is explained here in detail. The ORIGEN-2 calculation with the new ORIGEN-2 MOX library can predict the nuclides contents within 10% for U and Pu isotopes and 20% for both minor actinides and main FPs. (author)

  16. Integral test for Np237 and Am241 cross sections in JENDL, ENDF and JEF libraries

    Iwasaki, Tomohiko; Unesaki, Hironobu; Kitada, Takanori

    2002-01-01

    Experiments using Kyoto University critical assembly (KUCA) were performed for measuring the capture and fission reaction rates of 237 Np and 241 Am. A back-to-back fission chamber was employed for the measurement of the fission rate of 237 Np and 241 Am relative to 235 U. The capture rate of 237 Np relative to 197 Au was measured by using activation method. Eleven cores, of which the spectra were changed systematically, were mocked up for the present measurements. Five cores among the eleven were utilized for the fission reaction rate measurement. The experiment was analyzed using the Monte Carlo code MVP, the transport code TWOTRAN and the diffusion code CITATION using the libraries based on JENDL3.2, ENDF/B-VI and JEF2.2. As the results, for 237 Np, JENDL3.2 showed good agreement for both capture and fission. However, for the fission rate of 241 Am, JENDL3.2 underestimates 15-20%. On the other hand, ENDF/B-VI and JEF2.2 show different C/Es for 237 Np and 241 Am. (author)

  17. Development of a common nuclear group constants library system: JSSTDL-295n-104γ based on JENDL-3 nuclear data library

    Hasegawa, A.

    1992-01-01

    JSSTDL 295n-104γ: A common group cross-section library system has been developed in JAERI to be used in fairly wide range of applications in nuclear industry. This system is composed of a common 295n-104γ group cross-section library based on JENDL-3 nuclear data file and its utility codes. Target of this system is focused to the criticality or shielding calculations in fast and fusion reactors using ANISN, DOT, or MORSE code. Specifications of the common group constants were decided responding to the request from various nuclear data users, particularly from nuclear design group in Japan. Group structure is decided so as to cover almost all group structures currently used in our country. This library includes self-shielding factor tables for primary reactions. A routine for generating macro-scopic cross-section using the self-shielding factor table is also provided. Neutron cross-sections and photon production cross-sections are processed by Prof. GROUCH-G/B code system and γ ray transport cross-sections are generated by GAMLEG-JR. In this paper, outline and present status of the JSSTDL library system is described along with two examples adopted in JENDL-3 benchmark test. One is for shielding calculation, where effects of self-shielding factor (f-table) is shown in conjunction with the analysis of the ASPIS natural iron deep penetration experiment. Without considering resonance self-shielding effect in resonance energy region for resonant nuclides like iron, the results is completely missled in the attenuation profile calculation in the shields. The other example is fast rector criticality calculations of very small critical assemblies with very high enrichment fuel materials where some basic characteristics of this library is presented. (orig.)

  18. Radiation Litigation and Internal Dosimetry

    Jose, D.E.

    1987-01-01

    Radiation Litigation refers to those lawsuits filed by individuals who claim to have been injured by some past exposure to ionizing radiation. Law classifies these cases as personal injury or tort cases. However, they are a new breed of such cases and the law is presently struggling with whether these cases can be resolved using the traditional methods of legal analysis or whether new forms of analysis, such as probability of causation, need to be applied. There are no absolutely certain rules concerning how these particular lawsuits will be tried and analyzed. The United States presently is defending cases filed by approximately 7000 plaintiffs. The private nuclear industry is defending cases filed by over 2000 plaintiffs. While not all of these cases will actually be tried on their merits, at least some will and internal dosimetry will play a very important part in many of these trials

  19. Neutron Dosimetry

    Vanhavere, F.

    2001-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding

  20. Neutron Dosimetry

    Vanhavere, F

    2001-04-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding.

  1. Topics in radiation dosimetry radiation dosimetry

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  2. Radiation dosimetry

    Harper, M.W.; Thomas, B.; Conway, J.

    1977-01-01

    A dosemeter is described that is based on the TSCD principle (thermally stimulated current dosimetry). Basically this involves irradiating a responsive material and then heating it,whereby an electric current is produced. If the material is heated in an electric field the peak value of the thermally stimulated current or alternatively the total charge released by heating, can be related to the radiation dose received. The instrument described utilises a sheet coated with a thermoplastic polymer, such as a poly4-methylpent-l-ene. The polymer should have a softening point not lower than 150 0 C with an electrical resistivity of at least 10 16 chms/cm at 150 0 C. The polymer may also be PTFE. Heating should be in the range 150 0 C to 200 0 C and the electric field in the range 50 to 10,000V/mm. (U.K.)

  3. Organ dosimetry

    Kaul, Dean C.; Egbert, Stephen D.; Otis, Mark D.; Kuhn, Thomas; Kerr, George D.; Eckerman, Keith F.; Cristy, Mark; Ryman, Jeffrey C.; Tang, Jabo S.; Maruyama, Takashi

    1987-01-01

    This chapter describes the technical approach, complicating factors, and sensitivities and uncertainties of calculations of doses to the organs of the A-bomb survivors. It is the object of the effort so described to provide data that enables the dosimetry system to determine the fluence, kerma, absorbed dose, and similar quantities in 14 organs and the fetus, specified as being of radiobiological interest. This object was accomplished through the use of adjoint Monte Carlo computations, which use a number of random particle histories to determine the relationship of incident neutrons and gamma rays to those transported to a target organ. The system uses these histories to correlate externally-incident energy- and angle-differential fluences with the fluence spectrum (energy differential only) within the target organ. In order for the system to work in the most efficient manner possible, two levels of data were provided. The first level, represented by approximately 6,000 random adjoint-particle histories, enables the computation of the fluence spectrum with sufficient precision to provide statistically reliable (± 6 %) mean doses within any given organ. With this limited history inventory, the system can be run rapidly for all survivors. Mean organ dose and dose uncertainty are obtainable in this mode. The second mode of operation enables the system to produce a good approximation to fluence spectrum within any organ or to produce the dose in each of an array of organ subvolumes. To be statistically reliable, this level of detail requires far more random histories, approximately 40,000 per organ. Thus, operation of the dosimetry system in this mode (i.e., with this data set) is intended to be on an as-needed, organ-specific basis, since the system run time is eight times that in the mean dose mode. (author)

  4. ORIGEN2 libraries based on JENDL-3.2 for LWR-MOX fuels

    Suyama, Kenya; Katakura, Jun-ichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Onoue, Masaaki; Matsumoto, Hideki [Mitsubishi Heavy Industries Ltd., Tokyo (Japan); Sasahara, Akihiro [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

    2000-11-01

    A set of ORIGEN2 libraries for LWR MOX fuels was developed based on JENDL-3.2. The libraries were compiled with SWAT using the specification of MOX fuels that will be used in nuclear power reactors in Japan. The verification of the libraries were performed by the analyses of post irradiation examinations for the fuels from European PWR. By the analysis of PIE data from PWR in United States, the comparison was made between calculation and experimental results in the case of that parameters for making the libraries are different from irradiation conditions. These new libraries for LWR MOX fuels are packaged in ORLIBJ32, the libraries released in 1999. (author)

  5. Evaluated neutronic file for indium

    Smith, A.B.; Chiba, S.; Smith, D.L.; Meadows, J.W.; Guenther, P.T.; Lawson, R.D.; Howerton, R.J.

    1990-01-01

    A comprehensive evaluated neutronic data file for elemental indium is documented. This file, extending from 10 -5 eV to 20 MeV, is presented in the ENDF/B-VI format, and contains all neutron-induced processes necessary for the vast majority of neutronic applications. In addition, an evaluation of the 115 In(n,n') 116m In dosimetry reaction is presented as a separate file. Attention is given in quantitative values, with corresponding uncertainty information. These files have been submitted for consideration as a part of the ENDF/B-VI national evaluated-file system. 144 refs., 10 figs., 4 tabs

  6. ZZ SNLRML, Dosimetry Cross-Section Recommendations

    1996-01-01

    Description of program or function: Format: SAND-II; Number of groups: 640 group SAND-II group structure. Nuclides: Cd, B, Au, S, Ni, Li, F, Na, Mg, Al, Si, P, Sc, Ti, Mn, Fe, Co, Cu, Zn, Zr, Nb, Mo, Rh, Ag, In, I, Th, U, Np, Pu, Am. Origin: ENDF/B-VI, ENDF/B-V, IRDF-90, JENDL-3, JEF 2.2 and GLUCS data with special modifications from private communications. Weighting spectrum: flat. SNLRML is a reactor dosimetry library that draws upon all available evaluated cross section libraries and selects the best evaluation for application to research reactor spectrum determinations. Many of the components of the SNLRML come from the ENDF/B-VI and IRDF-90 (DLC-0161) libraries. The library format was selected for easy interface with spectrum determination codes such as SAND-II (CCC-0112 and LSL-M2 (PSR-233) and the new PSR-0345/SNL/SAND-II has been enhanced to interface with SNLRML. The data is recommended for spectrum determination applications and for the prediction of neutron activation of typical radiation sensor materials. The library has been tested for consistency of the cross section in wide variety of neutron environments. The results and cautions from this testing have been documented. The data has been interfaced with radiation transport codes, such as TWODANT-SYS (CCC-0547) and MCNP (CCC-0200), in order to compare calculated and measured activities for benchmark reactor experiments

  7. Personnel neutron dosimetry

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  8. CASMO5 JENDL-4.0 and ENDF/B-VII.1beta4 libraries

    Rhodes, J.; Gheorghiu, N.; Ferrer, R.

    2012-01-01

    This paper details the generation of neutron data libraries for the CASMO5 lattice physics code based on the recently released JENDL-4.0 and ENDF/B-VII.1beta4 nuclear data evaluations. This data represents state-of-the-art nuclear data for late-2011. The key features of the new evaluations are briefly described along with the procedure for processing of this data into CASMO5, 586-energy group neutron data libraries. Finally some CASMO5 results for standard UO 2 and MOX critical experiments for the two new libraries and the current ENDF/B-VII.0 CASMO5 library are presented including the B and W 1810 series, DIMPLE S06A, S06B, TCA reflector criticals with iron plates and the PNL-30-35 MOX criticals. The results show that CASMO5 with the new libraries is performing well for these criticals with a very slight edge in results to the JENDL-4.0 nuclear data evaluation over the ENDF/B-VII.1beta4 evaluation. Work is currently underway to generate a CASMO5 library based on the final ENDF/B-VII.R1 evaluation released Dec. 22, 2011. (authors)

  9. JENDL-4.0: A new library for nuclear science and engineering

    Shibata, Keiichi; Iwamoto, Osamu; Nakagawa, Tsuneo; Iwamoto, Nobuyuki; Ichihara, Akira; Kunieda, Satoshi; Chiba, Satoshi; Furutaka, Kazuyoshi; Katakura, Jun-ichi; Otuka, Naohiko; Ohsawa, Takaaki; Murata, Toru; Matsunobu, Hiroyuki; Zukeran, Atsushi; Kamada, So

    2011-01-01

    The fourth version of the Japanese Evaluated Nuclear Data Library has been produced in cooperation with the Japanese Nuclear Data Committee. In the new library, much emphasis is placed on the improvements of fission product and minor actinoid data. Two nuclear model codes were developed in order to evaluate the cross sections of fission products and minor actinoids. Coupled-channel optical model parameters, which can be applied to wide mass and energy regions, were obtained for nuclear model calculations. Thermal cross sections of actinoids were carefully examined by considering experimental data or by the systematics of neighboring nuclei. Most of the fission cross sections were derived from experimental data. A simultaneous evaluation was performed for the fission cross sections of important uranium and plutonium isotopes above 10 keV. New evaluations were performed for the thirty fission-product nuclides that had not been contained in the previous library JENDL-3.3. The data for light elements and structural materials were partly reevaluated. Moreover, covariances were estimated mainly for actinoids. The new library was released as JENDL-4.0, and the data can be retrieved from the Web site of the JAEA Nuclear Data Center. (author)

  10. Dosimetry for radiation processing

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  11. Total cross-sections assessment of neutron reaction with stainless steel SUS-310 contained in various nuclear data files

    Suwoto

    2002-01-01

    The integral testing of neutron cross-sections for Stainless Steel SUS-310 contained in various nuclear data files have been performed. The shielding benchmark calculations for Stainless Steel SUS-310 has been analysed through ORNL-Broomstick Experiment calculation which performed by MAERKER, R.E. at ORNL - USA ( 1) . Assessment with JENDL-3.1, JENDL-3.2, ENDF/B-IV, ENDF/B-VI nuclear data files and data from GEEL have also been carried out. The overall calculation results SUS-310 show in a good agreement with the experimental data, although, underestimate results appear below 3 MeV for all nuclear data files. These underestimation tendencies clearly caused by presented of iron nuclide which more than half in Stainless Steel compound. The total neutron cross-sections of iron nuclide contained in various nuclear data files relatively lower on that energy ranges

  12. Neutron dosimetry - A review

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  13. Chemical dosimetry principles in high dose dosimetry

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  14. Validation of actinide nuclear data from ENDF/B-V, INDL/A-83 and JENDL-2

    Paviotti Corcuera, R.; Moraes, M. de

    1988-11-01

    Resonance integrals and fission spectrum averaged cross sections are calculated for the actinides of ENDF/B-V, INDL/A-83 and JENDL-2. The results are compared with each other and with experimental data when available. The experimental data are scarce and there exist large differences among data from different libraries. (author). 16 refs, 4 tabs

  15. JENDL-3.2 performance in analyses of MISTRAL critical experiments for high-moderation MOX cores

    Takada, Naoyuki; Hibi, Koki; Ishii, Kazuya; Ando, Yoshihira; Yamamoto, Toru; Ueji, Masao; Iwata, Yutaka

    2001-01-01

    NUPEC and CEA have launched an extensive experimental program called MISTRAL to study highly moderated MOX cores for the advanced LWRs. The analyses using SRAC system and MVP code with JENDL-3.2 library are in progress on the experiments of the MISTRAL and the former EPICURE programs. Various comparisons have been made between calculation results and measurement values. (author)

  16. Dosimetry system 1986

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  17. Applications of gel dosimetry

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  18. Development of the adjusted nuclear cross-section library based on JENDL-3.2 for large FBR

    Yokoyama, Kenji; Ishikawa, Makoto; Numata, Kazuyuki

    1999-04-01

    JNC (and PNC) had developed the adjusted nuclear cross-section library in which the results of the JUPITER experiments were reflected. Using this adjusted library, the distinct improvement of the accuracy in nuclear design of FBR cores had been achieved. As a recent research, JNC develops a database of other integral data in addition to the JUPITER experiments, aiming at further improvement for accuracy and reliability. In 1991, the adjusted library based on JENDL-2, JFS-3-J2 (ADJ91R), was developed, and it has been used on the design research for FBR. As an evaluated nuclear library, however, JENDL-3.2 is recently used. Therefore, the authors developed an adjusted library based on JENDL-3.2 which is called JFS-3-J3.2(ADJ98). It is known that the adjusted library based on JENDL-2 overestimated the sodium void reactivity worth by 10-20%. It is expected that the adjusted library based on JENDL-3.2 solve the problem. The adjusted library JFS-3-J3.2(ADJ98) was produced with the same method as the adjusted library JFS-3-J2(ADJ91R) and used more integral parameters of JUPITER experiments than the adjusted library JFS-3-J2(ADJ91R). This report also describes the design accuracy estimation on a 600 MWe class FBR with the adjusted library JFS-3-J3.2(ADJ98). Its main nuclear design parameters (multiplication factor, burn-up reactivity loss, breeding ratio, etc.) except the sodium void reactivity worth which are calculated with the adjusted library JFS-3-J3.2(ADJ98) are almost the same as those predicted with JFS-3-J2(ADJ91R). As for the sodium void reactivity, the adjusted library JFS-3-J3.2(ADJ98) estimates about 4% smaller than the JFS-3-J2(ADJ91R) because of the change of the basic nuclear library from JENDL-2 to JENDL-3.2. (author)

  19. Isotopic analyses and calculation by use of JENDL-3.2 for high burn-up UO2 and MOX spent fuels

    Sasahara, Akihiro; Matsumura, Tetsuo; Nicolaou, G.; Betti, M.; Walker, C.T.

    1997-01-01

    The post irradiation examinations (PIE) were carried out for high burn-up UO 2 spent fuel (3.8%U235, average burn-up:60GWd/t) and mixed oxide (MOX) spent fuel (5.07%Pu, average burn-up:45GWd/t). The PIE includes, a) isotopic analysis, b) electron probe microanalysis (EPMA) in pellet cross section and so on. The results of isotopic analyses and EPMA were compared with ORIGEN2/82 and VIM-BURN calculation results. In VIM-BURN calculation, the nuclear data of actinides were proceeded from new data file, JENDL-3.2. The sensitivities of power history and moderator density to nuclides composition were investigated by VIM-BURN calculation and consequently power history mainly effected on Am241 and Am242m and moderator density effected on fissile nuclides. From EPMA results of U and Pu distribution in pellet, VIM-BURN calculation showed reasonable distribution in pellet cross section. (author)

  20. Isotopic analyses and calculation by use of JENDL-3.2 for high burn-up UO{sub 2} and MOX spent fuels

    Sasahara, Akihiro; Matsumura, Tetsuo [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.; Nicolaou, G.; Betti, M.; Walker, C.T.

    1997-03-01

    The post irradiation examinations (PIE) were carried out for high burn-up UO{sub 2} spent fuel (3.8%U235, average burn-up:60GWd/t) and mixed oxide (MOX) spent fuel (5.07%Pu, average burn-up:45GWd/t). The PIE includes, (a) isotopic analysis, (b) electron probe microanalysis (EPMA) in pellet cross section and so on. The results of isotopic analyses and EPMA were compared with ORIGEN2/82 and VIM-BURN calculation results. In VIM-BURN calculation, the nuclear data of actinides were proceeded from new data file, JENDL-3.2. The sensitivities of power history and moderator density to nuclides composition were investigated by VIM-BURN calculation and consequently power history mainly effected on Am241 and Am242m and moderator density effected on fissile nuclides. From EPMA results of U and Pu distribution in pellet, VIM-BURN calculation showed reasonable distribution in pellet cross section. (author)

  1. Benchmarking ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1

    Van Der Marck, S. C.

    2012-01-01

    Three nuclear data libraries have been tested extensively using criticality safety benchmark calculations. The three libraries are the new release of the US library ENDF/B-VII.1 (2011), the new release of the Japanese library JENDL-4.0 (2011), and the OECD/NEA library JEFF-3.1 (2006). All calculations were performed with the continuous-energy Monte Carlo code MCNP (version 4C3, as well as version 6-beta1). Around 2000 benchmark cases from the International Handbook of Criticality Safety Benchmark Experiments (ICSBEP) were used. The results were analyzed per ICSBEP category, and per element. Overall, the three libraries show similar performance on most criticality safety benchmarks. The largest differences are probably caused by elements such as Be, C, Fe, Zr, W. (authors)

  2. Curves and tables of neutron cross sections of fission product nuclei in JENDL-3

    Nakagawa, Tsuneo [ed.

    1992-06-15

    Neutron cross sections of 172 nuclei in the fission product region stored in JENDL-3 are shown in graphs and tables. The evaluation work of these nuclei was made by the Fission Product Nuclear Data Working Group of the Japanese Nuclear Data Committee, in the neutron energy region from 10{sup {minus}5} eV to 20 MeV. Almost of the cross section data reproduced in graphs in this report. The cross section averaged over 38 energy intervals are listed in a table. Shown in order tables are thermal cross sections, resonance integrals, Maxwellian neutron flux average cross sections, fission spectrum average cross sections, 14-MeV cross sections, one group average cross sections in neutron flux of typical types of fission reactors and average cross sections in the 30-keV Maxwellian spectrum.

  3. Evaluation of neutron nuclear data of 9Be for JENDL-3

    Shibata, Keiichi

    1984-12-01

    Neutron nuclear data of 9 Be have been evaluated for JENDL-3 in the energy range from 10 -5 eV to 20 MeV. Evaluated quantities are the total, elastic and inelastic scattering, photon-production, (n,γ), (n,p), (n,d), (n,t) and (n,α) reaction cross sections and the angular and energy distributions of neutrons. The total cross section below 830 keV was calculated with the R-matrix theory. The statistical model was applied to the prediction of the inelastic scattering and charged-particle emission cross sections. The (n,2n) reaction cross section is given by the sum of the inelastic scattering and (n,α 1 ) reaction cross sections. (author)

  4. Curves and tables of neutron cross sections of fission product nuclei in JENDL-3

    Nakagawa, Tsuneo

    1992-06-01

    Neutron cross sections of 172 nuclei in the fission product region stored in JENDL-3 are shown in graphs and tables. The evaluation work of these nuclei was made by the Fission Product Nuclear Data Working Group of the Japanese Nuclear Data Committee, in the neutron energy region from 10 -5 eV to 20 MeV. Almost all the cross section data are reproduced in graphs in this report. The cross section averaged over 38 energy intervals are listed in a table. Shown in other tables are thermal cross sections, resonance integrals, Maxwellian neutron flux average cross sections, fission spectrum average cross sections, 14-MeV cross sections, one group average cross sections in neutron flux of typical types of fission reactors and average cross sections in the 30-keV Maxwellian spectrum. (author)

  5. Evaluation of neutron nuclear data of 241pu for JENDL-2

    Kikuchi, Yasuyuki; Sekine, Nobuo

    1984-06-01

    Neutron nuclear data of 241 Pu were newly evaluated for JENDL-2. Evaluated quantities are the total, elastic and inelastic scattering, fission, capture, (n,2n), (n,3n) and (n,4n) reaction cross sections, the resolved and unresolved resonance parameters, the angular and energy distributions of emitted neutrons, and the average number of neutrons emitted per fission. The simultaneous evaluation method was adopted for the fission cross section so as to keep the consistency among the main fissile and fertile material nuclides. The theoretical calculations based on the spherical optical model and the statistical model were also used, when the experimental data were not sufficient. Discussion is given on the evaluation method. (author)

  6. Thermoluminescence albedo-neutron dosimetry

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  7. Thermoluminescence in medical dosimetry

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  8. Thin film tritium dosimetry

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  9. Internal sources dosimetry

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  10. Dosimetry of ionizing radiation

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  11. Benchmark test of evaluated nuclear data files for fast reactor neutronics application

    Chiba, Go; Hazama, Taira; Iwai, Takehiko; Numata, Kazuyuki

    2007-07-01

    A benchmark test of the latest evaluated nuclear data files, JENDL-3.3, JEFF-3.1 and ENDF/B-VII.0, has been carried out for fast reactor neutronics application. For this benchmark test, experimental data obtained at fast critical assemblies and fast power reactors are utilized. In addition to comparing of numerical solutions with the experimental data, we have extracted several cross sections, in which differences between three nuclear data files affect significantly numerical solutions, by virtue of sensitivity analyses. This benchmark test concludes that ENDF/B-VII.0 predicts well the neutronics characteristics of fast neutron systems rather than the other nuclear data files. (author)

  12. Comparison of {sup 235}U fission cross sections in JENDL-3.3 and ENDF/B-VI

    Kawano, Toshihiko [Kyushu Univ., Fukuoka (Japan); Carlson, Allan D. [National Institute of Standards and Technology (United States); Matsunobu, Hiroyuki [Data Engineering, Inc., Fujisawa, Kanagawa (Japan); Nakagawa, Tsuneo; Shibata, Keiichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Talou, Patrick; Young, Philip G.; Chadwick, Mark B. [Los Alamos National Laboratory, Los Alamos, NM (United States)

    2002-01-01

    Comparisons of evaluated fission cross sections for {sup 235}U in JENDL-3.3 and ENDF/B-VI are carried out. The comparisons are made for both the differential and integral data. The fission cross sections as well as the fission ratios are compared with the experimental data in detail. Spectrum averaged cross sections are calculated and compared with the measurements. The employed spectra are the {sup 235}U prompt fission neutron spectrum, the {sup 252}Cf spontaneous fission neutron spectrum, and the neutron spectrum produced by a {sup 9}Be(d, xn) reaction. For {sup 235}U prompt fission neutron spectrum, the ENDF/B-VI evaluation reproduces experimental averaged cross sections. For {sup 252}Cf and {sup 9}Be(d, xn) neutron spectra, the JENDL-3.3 evaluation gives better results than ENDF/B-VI. (author)

  13. Comparison of 235U fission cross sections in JENDL-3.3 and ENDF/B-VI

    Kawano, Toshihiko; Carlson, Allan D.; Matsunobu, Hiroyuki; Nakagawa, Tsuneo; Shibata, Keiichi

    2002-01-01

    Comparisons of evaluated fission cross sections for 235 U in JENDL-3.3 and ENDF/B-VI are carried out. The comparisons are made for both the differential and integral data. The fission cross sections as well as the fission ratios are compared with the experimental data in detail. Spectrum averaged cross sections are calculated and compared with the measurements. The employed spectra are the 235 U prompt fission neutron spectrum, the 252 Cf spontaneous fission neutron spectrum, and the neutron spectrum produced by a 9 Be(d, xn) reaction. For 235 U prompt fission neutron spectrum, the ENDF/B-VI evaluation reproduces experimental averaged cross sections. For 252 Cf and 9 Be(d, xn) neutron spectra, the JENDL-3.3 evaluation gives better results than ENDF/B-VI. (author)

  14. Benchmarks solutions of the coupled systems NJOY/AMPX-II/HAMMER-TECHNION and the library JENDL-3

    Santos, A. dos

    1991-01-01

    Benchmarks calculations were performed with the newest released japanese nuclear data library JENDL-3. The calculations were performed with the methodology developed at IPEN/CNEN-SP based on a coupled NJOY/AMPX-II/HAMMER-TECHNION system. The analyses show that the long-standing problem of the overprediction of the epithermal U-238 neutron capture still remains. Besides that there is an indication that the fission cross section of U-238 might be underestimated. (author)

  15. Radiochromic film dosimetry

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  16. Nuclear accident dosimetry

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  17. Personal dosimetry in Kazakhstan

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  18. Nuclear accident dosimetry

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  19. 100 years of solid state dosimetry and radiation protection dosimetry

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  20. Dosimetry for radiation processing

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  1. Software tool for portal dosimetry research.

    Vial, P; Hunt, P; Greer, P B; Oliver, L; Baldock, C

    2008-09-01

    This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commercially available treatment planning system (TPS). The software tool described in this work was developed to modify the TPS PDIP model by incorporating correction factors into the predicted EPID image to account for the difference in EPID response to open beam radiation and multileaf collimator (MLC) transmitted radiation. The processes performed by the software tool include; i) read the MLC file and the PDIP from the TPS, ii) calculate the fraction of beam-on time that each point in the IMRT beam is shielded by MLC leaves, iii) interpolate correction factors from look-up tables, iv) create a corrected PDIP image from the product of the original PDIP and the correction factors and write the corrected image to file, v) display, analyse, and export various image datasets. The software tool was developed using the Microsoft Visual Studio.NET framework with the C# compiler. The operation of the software tool was validated. This software provided useful tools for EPID dosimetry research, and it is being utilised and further developed in ongoing EPID dosimetry and IMRT dosimetry projects.

  2. Skyshine analysis using various nuclear data files

    Zharkov, V.P.; Dikareva, O.F.; Kartashev, I.A.; Kiselev, A.N. [Research and Development Inst. of Power Engineering, Moscow (Russian Federation); Nomura, Y.; Tsubosaka, A. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    2000-03-01

    The calculations of the spacial distributions of dose rate for neutron and secondary photons, thermal neutron fluxes and space-energy distributions of neutron and photons near the air-ground interface were performed by MCNP and DORT codes. Different nuclear data files were used (ENDF/B-IV, ENDF/B-VI, FENDL-2, JENDL-3.2). Either the standard pointwise libraries (MCNP) or special libraries prepared by NJOY code from ENDF/B and others' files were used. Prepared multigroup coupled neutron and photon cross sections libraries for DORT code had CASK-40 group energy structures. The libraries contain pointwise or multigroup cross sections data for all elements included in the atmosphere and ground composition. The validation of the calculated results was performed with using the experimental data obtained for the series of measurements at RA reactor. (author)

  3. Skyshine analysis using various nuclear data files

    Zharkov, V.P.; Dikareva, O.F.; Kartashev, I.A.; Kiselev, A.N.; Nomura, Y.; Tsubosaka, A.

    2000-01-01

    The calculations of the spacial distributions of dose rate for neutron and secondary photons, thermal neutron fluxes and space-energy distributions of neutron and photons near the air-ground interface were performed by MCNP and DORT codes. Different nuclear data files were used (ENDF/B-IV, ENDF/B-VI, FENDL-2, JENDL-3.2). Either the standard pointwise libraries (MCNP) or special libraries prepared by NJOY code from ENDF/B and others' files were used. Prepared multigroup coupled neutron and photon cross sections libraries for DORT code had CASK-40 group energy structures. The libraries contain pointwise or multigroup cross sections data for all elements included in the atmosphere and ground composition. The validation of the calculated results was performed with using the experimental data obtained for the series of measurements at RA reactor. (author)

  4. Activation cross section data file, (1)

    Yamamuro, Nobuhiro; Iijima, Shungo.

    1989-09-01

    To evaluate the radioisotope productions due to the neutron irradiation in fission of fusion reactors, the data for the activation cross sections ought to be provided. It is planning to file more than 2000 activation cross sections at final. In the current year, the neutron cross sections for 14 elements from Ni to W have been calculated and evaluated in the energy range 10 -5 to 20 MeV. The calculations with a simplified-input nuclear cross section calculation system SINCROS were described, and another method of evaluation which is consistent with the JENDL-3 were also mentioned. The results of cross section calculation are in good agreement with experimental data and they were stored in the file 8, 9 and 10 of ENDF/B format. (author)

  5. Neutron cross sections of 28 fission product nuclides adopted in JENDL-1

    Kikuchi, Yasuyuki; Nakagawa, Tsuneo; Igarasi, Sin-iti; Matsunobu, Hiroyuki; Kawai, Masayoshi; Iijima, Shungo.

    1981-02-01

    This is the final report concerning the evaluated neutron cross sections of 28 fission product nuclides adopted in the first version of Japanese Evaluated Nuclear Data Library (JENDL-1). These 28 nuclides were selected as being most important for fast reactor calculations, and are 90 Sr, 93 Zr, 95 Mo, 97 Mo, 99 Tc, 101 Ru, 102 Ru, 103 Rh, 104 Ru, 105 Pd, 106 Ru, 107 Pd, 109 Ag, 129 I, 131 Xe, 133 Cs, 135 Cs, 137 Cs, 143 Nd, 144 Ce, 144 Nd, 145 Nd, 147 Pm, 147 Sm, 149 Sm, 151 Sm, 153 Eu and 155 Eu. The status of the experimental data was reviewed over the whole energy range. The present evaluation was performed on the basis of the measured data with the aid of theoretical calculations. The optical and statical models were used for evaluation of the smooth cross sections. An improved method was developed in treating the multilevel Breit-Wigner formula for the resonance region. Various physical parameters and the level schemes, adopted in the present work are discussed by comparing with those used in the other evaluations such as ENDF/B-IV, CEA, CNEN-2 and RCN-2. Furthermore, the evaluation method and results are described in detail for each nuclide. The evaluated total, capture and inelastic scattering cross sections are compared with the other evaluated data and some recent measured data. Some problems of the present work are pointed out and ways of their improvement are suggested. (author)

  6. Polymer gel dosimetry

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  7. Theoretical basis for dosimetry

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  8. Dosimetry for radiation processing

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  9. Inter-comparison of High Energy Files (neutron-induced, from 20 to 150 MeV)

    Lee, Young-Ouk; Fukahori, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    Recent new applications using accelerator-driven system require well-tested nuclear data when modeling the interaction of neutrons above 20 MeV. This work is aimed to review evaluation methods applied in currently available neutron high energy files above 20 to 150 MeV, to inter-compare their evaluated cross sections on some important isotopes, and to analyze resulting discrepancies. Through out these, integrities and consistencies of the high energy files are checked, applicability of physics models and evaluation methodologies are assessed, and some directions are derived to improve and expand current JENDL High Energy File. (author)

  10. Dosimetry of internal emitters

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  11. Individual neutron dosimetry

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  12. Evaluations of cross sections on Zr, Nb, and W up to 200 MeV for JENDL high energy file

    Kunieda, Satoshi; Shigyo, Nobuhiro; Ishibashi, Kenji

    2005-01-01

    Nuclear data were evaluated on Zr isotopes, 93 Nb and W isotopes for neutron- and proton-induced reactions up to 200 MeV. Optical model potential parameters were determined to give good agreements with experimental values of elastic-scattering, total, and total-reaction cross sections by the traditional phenomenological approach. The GNASH nuclear model code was used for evaluations of particle-production cross sections. Since the direct inelastic-scatterings induced by the excitations of giant resonances are not negligible for medium/heavy nuclei, the calculation was performed to take them into consideration. For composite-particle emission cross sections from pre-equilibrium states, semi-empirical models were utilized to give good agreements with experimental data. Evaluated cross sections were compared with experimental values and the LA150 evaluations. (author)

  13. Dosimetry and Calibration Section

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  14. Update of WIMS-D libraries using JENDL-3.2, ENDF/B-VI.5 and JEF-2.2

    Gil, Choong Sup; Kim, Jung Do; Chang, Jong Wha

    2001-01-01

    The WIMS-D5 Libraries based on JENDL-3.2, ENDF/B-VI.5, and JEF-2.2 have been prepared and are being tested against the benchmark problems. Several sensitivity calculations for stabililty confirmation of the libraries were carried out such as the fission spectrum dependency, the self shielding effects of the elastic scattering cross sections, the self shielding effects of Pu -240 and Pu -242 capture cross sections below 4.0 eV, etc. The results of benchmark calculations with the libraries based on JENDL-3.2, ENDF/B-VI.5, JEF-2.2, and the '1986 library were intercompared. The predictions of criticalities and isotopic compositions with the updated libraries show good agreements with the measurements or the reference results. The multiplication factors with the library based on JENDL-3.2 are slightly higher than those of ENDF/B-VI.5 and JEF-2.2

  15. Image in nuclear dosimetry using thermoluminescent dosimetry

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  16. Benchmarking the new JENDL-4.0 library on criticality experiments of a research reactor with oxide LEU (20 w/o) fuel, light water moderator and beryllium reflectors

    Liem, Peng Hong; Sembiring, Tagor Malem

    2012-01-01

    Highlights: ► Benchmark calculations of the new JENDL-4.0 library. ► Thermal research reactor with oxide LEU fuel, H 2 O moderator and Be reflector. ► JENDL-4.0 library shows better C/E values for criticality evaluations. - Abstract: Benchmark calculations of the new JENDL-4.0 library on the criticality experiments of a thermal research reactor with oxide low enriched uranium (LEU, 20 w/o) fuel, light water moderator and beryllium reflector (RSG GAS) have been conducted using a continuous energy Monte Carlo code, MVP-II. The JENDL-4.0 library shows better C/E values compared to the former library JENDL-3.3 and other world-widely used latest libraries (ENDF/B-VII.0 and JEFF-3.1).

  17. Secondary standard dosimetry laboratory (SSDL)

    Md Saion bin Salikin.

    1983-01-01

    A secondary Standard Dosimetry Laboratory has been established in the Tun Ismail Research Centre, Malaysia as a national laboratory for reference and standardization purposes in the field of radiation dosimetry. This article gives brief accounts on the general information, development of the facility, programmes to be carried out as well as other information on the relevant aspects of the secondary standard dosimetry laboratory. (author)

  18. Evaluated nuclear-data file for niobium

    Smith, A.B.; Smith, D.L.; Howerton, R.J.

    1985-03-01

    A comprehensive evaluated nuclear-data file for elemental niobium is provided in the ENDF/B format. This file, extending over the energy range 10 -11 -20 MeV, is suitable for comprehensive neutronic calculations, particulary those dealing with fusion-energy systems. It also provides dosimetry information. Attention is given to the internal consistancy of the file, energy balance, and the quantitative specification of uncertainties. Comparisons are made with experimental data and previous evaluated files. The results of integral tests are described and remaining outstanding problem areas are cited. 107 refs

  19. Neutron dosimetry in biology

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  20. Film dosimetry for IMRT: sensitivity corrections

    Suchowerska, N.; Hoban, P.; Davison, A.; Metcalfe, P.

    2000-01-01

    Full text: The trend towards conformal, dynamic and intensity modulated radiotherapy treatments has furthered the need for true integrating dosimetry. In traditional radiotherapy, film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose, has been associated with several variables. These include the effects of film specific sensitivity, direction of exposure, chemical processing and film scanner sensitivity. In this study, a procedure is developed to account for these variables, with a particular view to film being used as a dosimeter for conformal treatments. An effective sensitometric curve was established by exposing part of a single sheet of film to known doses. All films were processed together and scanned using a DuoscanT1200 transmission scanner, resulting in 12 bit image files. The images were analysed using Osiris software and the results fitted to the modified Williamson equation: P P s (l - 10 αD ) This yields values of α [film sensitivity], and P s [saturation pixel value], allowing individual dosimetry films to be normalised to this sensitometric calibration curve. For validation, a piece of Kodak X Omat-V film was sealed in a head phantom and exposed to a total of 51 IMRT fields, delivered from 6 gantry angles. The rest of the sheet of film was resealed and exposed to four known doses, providing sensitometric data, specific to this exposure. All films were then processed, scanned and analysed as described above. Observed variations in serial films exposed to 50cGy is in the order of 9% [mean 25.0,standard deviation = 3.2]. The automatic gain of the scanner system typically contributed 4% variation and needs to be carefully monitored. Results indicate that by using the sensitometric data from each exposure, the collective errors can be minimised. The IMRT exposure results confirm that the above process is viable for use in dosimetry for conformal radiation therapy. Copyright (2000) Australasian

  1. INDIVIDUAL DOSIMETRY SERVICE

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual DosimetryWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MAY/JUNE will be available from their usual dispatchers on Tuesday 2 May.Please have your films changed before the 12 May.The colour of the dosimeter valid in is MAY/JUNE is YELLOW.Individual Dosimetry Service will be closed on Friday 28 April.

  2. Nuclear medicine radiation dosimetry

    McParland, Brian J

    2010-01-01

    Complexities of the requirements for accurate radiation dosimetry evaluation in both diagnostic and therapeutic nuclear medicine (including PET) have grown over the past decade. This is due primarily to four factors: growing consideration of accurate patient-specific treatment planning for radionuclide therapy as a means of improving the therapeutic benefit, development of more realistic anthropomorphic phantoms and their use in estimating radiation transport and dosimetry in patients, design and use of advanced Monte Carlo algorithms in calculating the above-mentioned radiation transport and

  3. Generation, Testing, and Validation of a WIMS-D/4 Multigroup Cross-Section Library Based on the JENDL-3.2 Nuclear Data

    Rahman, Mafizur; Takano, Hideki

    2001-01-01

    A new 69-group library of multigroup constants for the lattice code WIMS-D/4 has been generated with an improved resonance treatment, processing nuclear data from JENDL-3.2 by NJOY91.108. A parallel ENDF/B-VI based library has also been constructed for intercomparison of results. Benchmark calculations for a number of thermal reactor critical assemblies of both uranium and plutonium fuels have been performed with the code WIMS-D/4.1 with its three different libraries: the original WIMS library (NEA-0329/10) and the new ENDF/B-VI and JENDL-3.2 based libraries. The results calculated with both ENDF and JENDL based libraries show a similar tendency and are found in better agreement with the experimental values. Benchmark parameters are further calculated with the comprehensive lattice code SRAC95. The results from SRAC95 and WIMS-D/4.1 (both using JENDL-3.2 based libraries) agree well with each other. The new library is also verified for its applicability to mixed-oxide cores of varying plutonium contents

  4. Integral test of JENDL-3.2 data by re-analysis of sample reactivity measurements at SEG and STEK facilities

    Dietze, Klaus

    2001-01-01

    Sample reactivity measurements, which have been performed at the fast-thermal coupled facilities RRR/SEG and STEK, have been re-analyzed using the JNC route for reactor calculation JENDL-3.2 // SLAROM / CITATION / PERKY. C/E-values of central reactivity worths (CRW) of FP nuclides, structural materials, and standards are given. (author)

  5. [Automatic Extraction and Analysis of Dosimetry Data in Radiotherapy Plans].

    Song, Wei; Zhao, Di; Lu, Hong; Zhang, Biyun; Ma, Jun; Yu, Dahai

    To improve the efficiency and accuracy of extraction and analysis of dosimetry data in radiotherapy plans for a batch of patients. With the interface function provided in Matlab platform, a program was written to extract the dosimetry data exported from treatment planning system in DICOM RT format and exported the dose-volume data to an Excel file with the SPSS compatible format. This method was compared with manual operation for 14 gastric carcinoma patients to validate the efficiency and accuracy. The output Excel data were compatible with SPSS in format, the dosimetry data error for PTV dose interval of 90%-98%, PTV dose interval of 99%-106% and all OARs were -3.48E-5 ± 3.01E-5, -1.11E-3 ± 7.68E-4, -7.85E-5 ± 9.91E-5 respectively. Compared with manual operation, the time required was reduced from 5.3 h to 0.19 h and input error was reduced from 0.002 to 0. The automatic extraction of dosimetry data in DICOM RT format for batch patients, the SPSS compatible data exportation, quick analysis were achieved in this paper. The efficiency of clinical researches based on dosimetry data analysis of large number of patients will be improved with this methods.

  6. Personnel photographic film dosimetry

    Keirim-Markus, I.B.

    1981-01-01

    Technology of personnel photographic film dosimetry (PPD) based on the photographic effect of ionizing radiation is described briefly. Kinds of roentgen films used in PPD method are enumerated, compositions of a developer and fixing agents for these films are given [ru

  7. Dosimetry and Calibration Section

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  8. Dosimetry of pion beams

    Dicello, J.F.

    1975-01-01

    Negative pion beams are probably the most esoteric and most complicated type of radiation which has been suggested for use in clinical radiotherapy. Because of the limited availability of pion beams in the past, even to nuclear physicists, there exist relatively fewer basic data for this modality. Pion dosimetry is discussed

  9. High frequency electromagnetic dosimetry

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  10. Group: radiation dosimetry

    Caldas, L.V.E.

    1990-01-01

    The main activities of the radiation dosimetry group is described, including the calibration of instruments, sources and radioactive solutions and the determination of neutron flux; development, production and market dosimetric materials; development radiation sensor make the control of radiation dose received by IPEN workers; development new techniques for monitoring, etc. (C.G.C.)

  11. Glucinium dosimetry in beryl

    Kremer, M.

    1949-05-01

    The application of the method developed by Kolthoff and Sandell (1928) for the dosimetry of glucinium (beryllium) in beryl gives non-reproducible results with up to 20% discrepancies. This method recommends to separate beryllium and aluminium using 8 hydroxyquinoline and then to directly precipitate glucinium in the filtrate using ammonia. One possible reason of the problems generated by this method should be the formation of a volatile complex between beryllium and the oxine. This work shows that when the oxine is eliminated before the precipitation with ammonia the dosimetry of beryllium becomes accurate. The destruction of the oxine requires the dry evaporation of the filtrate, which is a long process. Thus the search for a reagent allowing the quantitative precipitation of beryllium in its solutions and in presence of oxine has been made. It has been verified also that the quantitative precipitation of the double beryllium and ammonium phosphate is not disturbed by the oxine in acetic buffer. This method, which gives good results, has also the advantage to separate beryllium from the alkaline-earth compounds still present in the filtrate. The report details the operation mode of the method: beryllium dosimetry using ammonium phosphate, aluminium-beryllium separation, application to beryl dosimetry (ore processing, insolubilization of silica, precipitation with ammonia, precipitation with oxine, precipitation of PO 4 NH 4 Gl, preciseness). (J.S.)

  12. Instrumentation in thermoluminescence dosimetry

    Julius, H.W.

    1986-01-01

    In the performance of a thermoluminescence dosimetry (TLD) system the equipment plays an important role. Crucial parameters of instrumentation in TLD are discussed in some detail. A review is given of equipment available on the market today - with some emphasis on automation - which is partly based on information from industry and others involved in research and development. (author)

  13. Solid state radiation dosimetry

    Moran, P.R.

    1976-01-01

    Important recent developments provide accurate, sensitive, and reliable radiation measurements by using solid state radiation dosimetry methods. A review of the basic phenomena, devices, practical limitations, and categories of solid state methods is presented. The primary focus is upon the general physics underlying radiation measurements with solid state devices

  14. Dosimetry and shielding

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  15. Development of Indian cross section data files for Th-232 and U-233 and integral validation studies

    Ganesan, S.

    1988-01-01

    This paper presents an overview of the tasks performed towards the development of Indian cross section data files for Th-232 and U-233. Discrepancies in various neutron induced reaction cross sections in various available evaluated data files have been obtained by processing the basic data into multigroup form and intercomparison of the latter. Interesting results of integral validation studies for capture, fission and (n,2n) cross sections for Th-232 by analyses of selected integral measurements are presented. In the resonance range, energy regions where significant differences in the calculated self-shielding factors for Th-232 occur have been identified by a comparison of self-shielded multigroup cross sections derived from two recent evaluated data files, viz., ENDF/B-V (Rev.2) and JENDL-2, for several dilutions and temperatures. For U-233, the three different basic data files ENDF/B-IV, JENDL-2 and ENDL-84 were intercompared. Interesting observations on the predictional capability of these files for the criticality of the spherical metal U-233 system are given. The current status of Indian data file is presented. (author) 62 ref

  16. Acute ingestion dosimetry using the ICRP 30 gastrointestinal tract model

    Cassels, B.M.

    1987-01-01

    This paper examines the gastrointestinal (GI) tract model used for dosimetry as outlined in ICRP30, to allow quick calculations of effective dose equivalents for acute radionuclide ingestion. A computer program has been developed to emulate the GI tract model. The program and associated data files are structured so that the GI tract model parameters can be varied, while the file structure and algorithm for the GI tract model should require minimal modification to allow the same theories that apply in this model to be used for other dosimetric models

  17. Textbook of dosimetry. 4. ed.

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  18. Use of the nuclear data in the reactor dosimetry: limitations, improvements and perspectives

    Destouches, C.; Domergue, C.; Beretz, D.; Gregoire, G.; Habert, B.

    2008-01-01

    This paper has briefly presented the main steps of the reactor dosimetry process. Each step, activity measurement, reaction rate derivation and neutron spectrum unfolding process has been analysed from a dosimetry point of view and improvements are asked in the knowledge of the following issues. First, for activity measurements: attenuation coefficients (μ/ρ) especially for X measurements, emission intensity I γ for 115m In and I X for 103m Rh. Secondly, for cross sections: improvements are useful but before, a new in-depth analysis of the recent releases of Endf-B7, JEFF3, EAF2005, JENDL3.3 should be done with a focus on the covariance matrices. Results of this study should give place to a new release of the IRDF2002 evaluation. Thirdly, for fission spectrum modelling: a study of the fission spectra modelling would be interesting to improve the accuracy of both the experimental benchmarks and of neutron core spectrum calculations by neutron codes. Fourthly, for benchmarks: an extension of the database with new reactions and integral measurements in fission spectra ( 252 Cf, 235 U, or mixed 239 Pu- 235 U) should be performed

  19. Analysis of OKTAVIAN Shielding Benchmark Experiments by ENDF/B-VII, JEFF-3.1, and JENDL-3.3

    Kim, Do-Heon; Gil, Choong-Sup; Lee, Young-Ouk

    2007-01-01

    International collaborations for the ITER Project and other fusion-related development projects have been conducted to create a reference fusion nuclear data library such as FENDL, which was a collection of the best cross section data from national nuclear data libraries. Recent release of newly evaluated nuclear data libraries requires an extensive and intensive benchmarking of the updated transport libraries to become a candidate for the future collection. In this study, the pulsed sphere experiments for leakage neutron and gamma-ray spectra at the D-T neutron source facility of Osaka University, OKTAVIAN were employed to test the ENDF/B-VII beta 1, JEFF-3.1, and JENDL-3.3 libraries. The continuous energy Monte Carlo transport code MCNPX-2.5 was used along with the ACE format libraries processed by a modified version of the NJOY99.90 code

  20. Modern methods of personnel dosimetry

    Kraus, W.; Herrmann, D.; Kiesewetter, W.

    The physical properties of radiation detectors for personnel dosimetry are described and compared. The suitability of different types of dosimeters for operational and central monitoring of normal occupational exposure, for accident and catastrophe dosimetry and for background and space-flight dosimetry is discussed. The difficulties in interpreting the dosimeter reading with respect to the dose in individual body organs are discussed briefly. 430 literature citations (up to Spring 1966) are given

  1. The dosimetry of ionizing radiation

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  2. Interlaboratory niobium dosimetry comparison

    Wille, P.

    1980-01-01

    For an interlaboratory comparison of neutron dosimetry using niobium the 93 sup(m)Nb activities of irradiated niobium monitors were measured. This work was performed to compare the applied techniques of dosimetry with Nb in different laboratories. The niobium monitors were irradiated in the fast breeder EBRII, USA and the BR2, Belgium. The monitors were dissolved and several samples were prepared. Their niobium contents were determined by the 94 Nb-count rates. since the original specific count rate was known. The KX radiations of the 93 sup(m)Nb of the samples and of a calibrated Nb-foil were compared. This foil was measured by PTB, Braunschweig and CBNM, Geel, which we additionally compared with the KX radiation of 88 Sr produced by a thin 88 Y source from a 88 Y-standard solution (PTB). (orig.) [de

  3. Neutron beam measurement dosimetry

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  4. Hanford External Dosimetry Program

    Fix, J.J.

    1990-10-01

    This document describes the Hanford External Dosimetry Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy (DOE) and its Hanford contractors. Program services include administrating the Hanford personnel dosimeter processing program and ensuring that the related dosimeter data accurately reflect occupational dose received by Hanford personnel or visitors. Specific chapters of this report deal with the following subjects: personnel dosimetry organizations at Hanford and the associated DOE and contractor exposure guidelines; types, characteristics, and procurement of personnel dosimeters used at Hanford; personnel dosimeter identification, acceptance testing, accountability, and exchange; dosimeter processing and data recording practices; standard sources, calibration factors, and calibration processes (including algorithms) used for calibrating Hanford personnel dosimeters; system operating parameters required for assurance of dosimeter processing quality control; special dose evaluation methods applied for individuals under abnormal circumstances (i.e., lost results, etc.); and methods for evaluating personnel doses from nuclear accidents. 1 ref., 14 figs., 5 tabs

  5. Thermo-luminescent dosimetry

    Reither, M; Schorn, B; Schneider, E

    1981-01-01

    The development of paediatric radiology which began in the late 195O's has been characterised by the need to limit the dose of ionising radiation to which the child is subjected. The aim has been to keep radiation exposure as low as possible by the introduction of suitable techniques and by the development of new methods. It is therefore surprising that studies in dosimetry in the paediaytric age range have only been carried out in recent years. One reason for this may have been the fact that a suitable technique of measurement was not available at the time. The introduction of solid state dosimetry based on thermo-luminescence, first into radiotherapy (1968) and subsequently into radiodiagnosis, has made it possible to abandon the previously widely used ionisation chamber. The purpose of the present paper is to indicate the suitability of this form of dose measurement for paediatric radiological purposes and to stimulate its application in this field.

  6. Legal aspects of dosimetry

    Pomarola, H.

    1976-01-01

    The use of ionizing radiations is regulated in France in all fields of application. The main principles governing inspection activities in the food industry are outlined. Conventional preservation methods are mentioned, after which a discussion is devoted to the preservation of food products by irradiation treatment and the increasing importance given to this technique. Consumer protection automatically implies the obligatory use of dosimetry by inspection organisms if the irradiated merchandise is likely to serve for human or animal consumption. Irradiation treatment permits are granted in a context of specific statutory texts mentioned here. Supervision is constant, but always both realistic and flexible. Each aspect of this treatment is discussed in maximum detail if not quite exhaustively, with special emphasis on dosimetry as an indispensable safety factor [fr

  7. WIPP radiation dosimetry program

    Wu, C.F.

    1991-01-01

    Radiation dosimetry is the process by which various measurement results and procedures are applied to quantify the radiation exposure of an individual. Accurate and precise determination of radiation dose is a key factor to the success of a radiation protection program. The Waste Isolation Pilot Plant (WIPP), a Department of Energy (DOE) facility designed for permanent repository of transuranic wastes in a 2000-foot-thick salt bed 2150 feet underground, has established a dosimetry program developed to meet the requirements of DOE Order 5480.11, ''Radiation Protection for Occupational Workers''; ANSI/ASME NQA-1, ''Quality Assurance Program Requirements for Nuclear Facilities''; DOE Order 5484.1, ''Environmental Protection, Safety, and Health Protection Information Reporting Requirements''; and other applicable regulations

  8. Quantitative imaging for clinical dosimetry

    Bardies, Manuel [INSERM U601, 9 Quai Moncousu, 44093 Nantes (France)]. E-mail: manu@nantes.inserm.fr; Flux, Glenn [Department of Physics, Royal Marsden NHS Trust, Sutton (United Kingdom); Lassmann, Michael [Department of Nuclear Medicine, Julis-Maximilians University, Wuerzburg (Germany); Monsieurs, Myriam [Department of Health Physics, University of Ghent, 9000 Ghent (Belgium); Savolainen, Sauli [Department of Physical Sciences, University of Helsinki and HUS, Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland); Strand, Sven-Erik [Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University (Sweden)

    2006-12-20

    Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.

  9. Sixth symposium on neutron dosimetry

    1987-01-01

    This booklet contains all abstracts of papers presented in 13 sessions. Main topics: Cross sections and Kerma factors; analytical radiobiology; detectors for personnel monitoring; secondary charged particles and microdosimetric basis of q-value for neutrons; personnel dosimetry; concepts for radiation protection; ambient monitoring; TEPC and ion chambers in radiation protection; beam dosimetry; track detectors (CR-39); dosimetry at biomedical irradiation facilities; health physics at therapy facilities; calibration for radiation protection; devices for beam dosimetry (TLD and miscellaneous); therapy and biomedical irradiation facilities; treatment planning. (HP)

  10. Dosimetry for Crystals Irradiation

    Lecomte, Pierre

    2005-01-01

    Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.

  11. INDIVIDUAL DOSIMETRY SERVICE

    1999-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact the Individual Dosimetry ServiceWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period JANUARY/FEBRUARY will be available from their usual dispatchers on Monday the third of January 2000.Please have your films changed:before the 12 January.The colour of the dosimeter valid in JANUARY/FEBRUARY is WHITE.

  12. INDIVIDUAL DOSIMETRY SERVICE

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact the Individual Dosimetry Service.We inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MARCH/APRIL will be available from their usual dispatchers on the third of March 2000.Please have your films changed before the 13th of March.The colour of the dosimeter valid in MARCH/APRIL is BLUE.

  13. Personal radon daughter dosimetry

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  14. Personnel radiation dosimetry

    1987-01-01

    The book contains the 21 technical papers presented at the Technical Committee Meeting to Elaborate Procedures and Data for the Intercomparison of Personnel Dosimeters organizaed by the IAEA on 22-26 April 1985. A separate abstract was prepared for each of these papers. A list of areas in which additional research and development work is needed and recommendations for an IAEA-sponsored intercomparison program on personnel dosimetry is also included

  15. Radiochromic film dosimetry

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  16. Dosimetry: an ARDENT topic

    CERN Bulletin

    2012-01-01

    The first annual ARDENT workshop took place in Vienna from 20 to 23 November. The workshop gathered together the Early-Stage Researchers (ESR) and their supervisors, plus other people involved from all the participating institutions.   “The meeting, which was organised with the local support of the Austrian Institute of Technology, was a nice opportunity for the ESRs to get together, meet each other, and present their research plans and some preliminary results of their work,” says Marco Silari, a member of CERN Radiation Protection Group and the scientist in charge of the programme. Two full days were devoted to a training course on radiation dosimetry, delivered by renowned experts. The workshop closed with a half-day visit to the MedAustron facility in Wiener Neustadt. ARDENT (Advanced Radiation Dosimetry European Network Training) is a Marie Curie ITN project funded under EU FP7 with €4 million. The project focuses on radiation dosimetry exploiting se...

  17. Dosimetry in dentistry.

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  18. Dosimetry in life sciences

    1975-01-01

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  19. Dosimetry in life sciences

    NONE

    1975-06-15

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  20. Automated four-dimensional Monte Carlo workflow using log files and real-time motion monitoring

    Sibolt, Patrik; Cronholm, R.O.; Heath, E.

    2017-01-01

    been developed in python. The workflow has been tested and verified using an in-house developed dosimetry system comprised of a dynamic thorax phantom constructed for plastic scintillator dosimetry. The workflow is directly compatible with any treatment planning system and can also be triggered...... by the appearance of linac log files. It has minimum user interaction and, with the use of linac log files, it provides a method for verification of the actually delivered dose in the patient geometry....

  1. BASACF, Integral Neutron Spectra Adjustment and Dosimetry

    Tichy, Milos

    1996-01-01

    1 - Description of program or function: Adjustment of a neutron spectrum based on integral detector measurements and calculation of an integral dosimetric quantity (integral flux, d.p.a., dose equivalent) and its variance. The program requires measured data (activities and their covariance matrix) and a priori information (spectrum, dosimetry cross sections, integral quantity conversion factor and their covariance matrices). All a priori covariance matrices can be read in from a file prepared by some other code or can be generated by means of three different methods (by subroutines included in the program). A subroutine which can normalize the a priori flux to measured data is also included. The program provides also adjusted dosimetry cross sections (with covariance matrix) so that it can be used for an adjustment of cross sections (or response functions of e.g. Bonner balls) by measurements in well-known neutron spectra. 2 - Method of solution: Bayesian theorem on conditional probability applied to linearized relation between activities, dosimetry cross sections and flux. All probability distributions are supposed to be normal and this supposition leads to minimizing of the same functional as least squares method (STAY'SL). This task is solved by a covariance filter method which avoids any matrix inversion and is numerically robust and stable. 3 - Restrictions on the complexity of the problem: This version can use 45 energy groups and 5 detectors and occupies 310 kB of main memory. This restriction can be modified according to available memory. The covariance matrix of activities is supposed diagonal. A solution is produced for any set of input data but in the case of non-consistent data, when measured activities do not match the a priori flux, the solution is not very meaningful

  2. Advances in biomedical dosimetry

    1981-01-01

    Full text: Radiation dosimetry, the accurate determination of the absorbed dose within an irradiated body or a piece of material, is a prerequisite for all applications of ionizing radiation. This has been known since the very first radiation applications in medicine and biology, and increasing efforts are being made by radiation researchers to develop more reliable, effective and safe instruments, and to further improve dosimetric accuracy for all types of radiation used. Development of new techniques and instrumentation was particularly fast in the field of both medical diagnostic and therapeutic radiology. Thus, in Paris in October the IAEA held the latest symposium in its continuing series on dosimetry in medicine and biology. The last one was held in Vienna in 1975. High-quality dosimetry is obviously of great importance for human health, whether the objectives lie in the prevention and control of risks associated with the nuclear industry, in medical uses of radioactive substances or X-ray beams for diagnostic purposes, or in the application of photon, electron or neutron beams in radiotherapy. The symposium dealt with the following subjects: General aspects of dosimetry; Special physical and biomedical aspects; Determination of absorbed dose; Standardization and calibration of dosimetric systems; and Development of dosimetric systems. The forty or so papers presented and the discussions that followed them brought out a certain number of dominant themes, among which three deserve particular mention. - The recent generalization of the International System of Units having prompted a fundamental reassessment of the dosimetric quantities to be considered in calibrating measuring instruments, various proposals were advanced by the representatives of national metrology laboratories to replace the quantity 'exposure' (SI unit = coulomb/kg) by 'Kerma' or 'absorbed dose' (unit joule/kg, the special name of which is 'gray'), this latter being closer to the practical

  3. Special workshop on lung dosimetry

    Fisher, D.R.

    1983-01-01

    A Special Workshop on Lung Dosimetry was convened in Salt Lake City, Utah, on April 21-22, 1982, to stimulate the use of improved radiation dosimetry and to formulate a stronger basis for dose-response relationships for inhaled radionuclides. The two-day workshop was held in conjunction with the 30th Annual Meeting of the Radiation Research Society. Publication is planned

  4. Neutron integral test of graphite cross sections in MeV energy region for the JENDL-3T through an analysis of WINFRITH shielding experiment

    Ueki, Kohtaro; Sakurai, Kiyoshi.

    1988-01-01

    The neutron integral tests of graphite cross sections in MeV neutron energy region for the ENDF/B-IV, JENDL-2, JENDL-3PR1 and -3T were performed through the Monte Carlo analysis of the graphite shielding experiment at the WINFRITH. The measured values were on the reaction rates of 115 In(n,n') 115m In, 27 Al(n,α) 24 Na, 32 S(n,p) 32 P, and 103 Rh(n,n') 103m Rh threshold detectors located in the graphite slabs, so that the experiment on the graphite was good at the integral test of neutron cross sections in MeV energy resion. (author)

  5. Verification OFENDF/B-VII.0, ENDF/B-VII.1 and JENDL-4.0 nuclear data libraries for criticality calculations using NEA/NSC benchmarks

    Bouhaddane, A.; Farkas, G.; Hascik, J.; Slugen, V.

    2015-01-01

    The paper presents verification of selected nuclear data libraries with the aim to apply them to fast reactor calculations. More precise results were achieved for thermal neutrons calculations. This corresponds with the demand for more precise nuclear data for fast reactors. However, fast neutron calculations show some consistency, in particular between ENDF-B/VII.1 and JENDL-4.0 nuclear data libraries. The results support the idea to prefer using newer ENDF-B/VII.1 instead of the previous version ENDF-B/VII.0. Certainly, there are still some issues to be addressed and there is potential to gain more conclusive results. Although, application of ENDF-B/VII.1 and JENDL-4.0 is expected for further calculations. (authors)

  6. Aqueous chemical dosimetry

    Matthews, R.W.

    1982-01-01

    Aqueous chemical dosimetry based on ceric and ferrous sulfate solutions and on a number of fluorescence-induced systems is reviewed. Particular attention is given to the factors affecting the response of these dosimeters to radiation and the corrections necessary for more accurate dosimetry under various irradiation conditions. The effect of cerous and ceric ion, oxygen, and sulfuric acid concentration on the ceric dosimeter is discussed together with the effects of temperature, energy of radiation, degraded energy spectra, and peroxysulfuric acids. Practical aspects of ceric/cerous dosimetry are given. Although ferrous sulfate solution is the most important and widely studied reference dosimeter, general agreement has not been reached on the ''best'' value for the molar extinction coefficient of ferric ions nor on the correction necessary to the G(Fe 3 - ) value for irradiations at temperatures significantly different from 25 0 C. New data are presented which indicate that the larger temperature coefficients given in the literature are more accurate. The ferrous sulfate system has been of great importance in establishing the primary radiolytic yields for 0.4 M sulfuric acid solution; it is shown how the failure to take into account the effect of oxygen and ferrous sulfate concentrations has led to erroneously high estimates of the zero solute concentration values in acid solutions. Some of the methods for extending the dose ranges measurable with ferrous sulfate-based solutions are reviewed. Substances which on irradiation give highly fluorescent products are among the most sensitive aqueous chemical dosimeters. These include benzoate and terephthalate solutions and the more recent coumarin and trimesate solutions. Advantages and disadvantages system are discussed. (author)

  7. Heavy-ion dosimetry

    Schimmerling, W.

    1980-03-01

    This lecture deals with some of the more important physical characteristics of relativistic heavy ions and their measurement, with beam delivery and beam monitoring, and with conventional radiation dosimetry as used in the operation of the BEVALAC biomedical facility for high energy heavy ions (Lyman and Howard, 1977; BEVALAC, 1977). Even so, many fundamental aspects of the interaction of relativistic heavy ions with matter, including important atomic physics and radiation chemical considerations, are not discussed beyond the reminder that such additional understanding is required before an adequte perspective of the problem can be attained

  8. Individual dosimetry and calibration

    Hoefert, M.; Nielsen, M.

    1996-01-01

    In 1995 both the Individual Dosimetry and Calibration Sections worked under the condition of a status quo and concentrated fully on the routine part of their work. Nevertheless, the machine for printing the bar code which will be glued onto the film holder and hence identify the people when entering into high radiation areas was put into operation and most of the holders were equipped with the new identification. As far as the Calibration Section is concerned the project of the new source control system that is realized by the Technical Support Section was somewhat accelerated

  9. NRPB patient dosimetry service

    Shrimpton, P.; Hillier, M.; Bungay, D.; Wall, B.

    1994-01-01

    For nearly 20 years, thermoluminescent dosemeters (TLDs) have been used by NRPB to investigate the doses received by patients undergoing diagnostic examinations with x-rays, and these measurements have formed the basis for national recommendations on patient protection. Monitoring typical levels of patient dose should represent an essential element of routine quality assurance in x-ray departments. In order to promote more widespread measurements in hospitals, NRPB has drawn on a wealth of experience to establish a high-quality service providing TLDs for medical dosimetry by post. (author)

  10. Internal dosimetry and control

    Rich, B.L.

    1990-05-01

    This internal dosimetry and control report provides guidance for EG ampersand G Idaho, Inc., field programs in detecting, evaluating, and controlling personnel exposure resulting from uptake of radionuclides by the body. Procedures specific to each program or facility are required to define the details of guidance from this report. Fundamental principles related to philosophy, policies, monitoring guidelines, and dose evaluation are discussed. Specific numerical guides and action levels are developed to guide the programs in evaluating the significance of specific analytical results. The requirement to thoroughly document the results and provide a formal technical base for each policy and/or practice is outlined and explained. 8 refs., 3 figs., 7 tabs

  11. Dosimetry in Radiology

    Andisco, D.; Blanco, S.; Buzzi, A.E

    2014-01-01

    The steady growth in the use of ionizing radiation in diagnostic imaging requires to maintain a proper management of patient’s dose. Dosimetry in Radiology is a difficult topic to address, but vital for proper estimation of the dose the patient is receiving. The awareness that every day is perceived in our country on these issues is the appropriate response to this problem. This article describes the main dosimetric units used and easily exemplifies doses in radiology through internationally known reference values. (authors) [es

  12. INDIVIDUAL DOSIMETRY SERVICE

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual Dosimetry ServiceWe inform all staffs and users under regular dosimetric control that the dosimeters for the monitoring period JULY/AUGUST are available from their usual dispatchers.Please have your films changed before the 10th of July.The colour of the dosimeter valid in JULY/AUGUST is PINK.

  13. Fast neutron dosimetry

    DeLuca, P.M. Jr.; Pearson, D.W.

    1992-01-01

    This progress report concentrates on two major areas of dosimetry research: measurement of fast neutron kerma factors for several elements for monochromatic and white spectrum neutron fields and determination of the response of thermoluminescent phosphors to various ultra-soft X-ray energies and beta-rays. Dr. Zhixin Zhou from the Shanghai Institute of Radiation Medicine, People's Republic of China brought with him special expertise in the fabrication and use of ultra-thin TLD materials. Such materials are not available in the USA. The rather unique properties of these materials were investigated during this grant period

  14. Tritium dosimetry and standardization

    Balonov, M.I.

    1983-01-01

    Actual problem of radiation hygiene such as an evaluation of human irradiation hazard due to a contact with tritium compounds both in industrial and public spheres is under discussion. Sources of tritium release to environment are characterized. Methods of tritium radiation monitoring are discussed. Methods of dosimetry of internal human exposure resulted from tritium compounds are developed on the base of modern representations on metbolism and tritium radiobiological effect. A system of standardization of permissible intake of tritium compounds for personnel and persons of population is grounded. Some protection measures are proposed as applied to tritium overdosage

  15. Internal Dosimetry. Chapter 18

    Hindorf, C. [Department of Radiation Physics, Skåne University Hospital, Lund (Sweden)

    2014-12-15

    The Committee on Medical Internal Radiation Dose (MIRD) is a committee within the Society of Nuclear Medicine. The MIRD Committee was formed in 1965 with the mission to standardize internal dosimetry calculations, improve the published emission data for radionuclides and enhance the data on pharmacokinetics for radiopharmaceuticals [18.1]. A unified approach to internal dosimetry was published by the MIRD Committee in 1968, MIRD Pamphlet No. 1 [18.2], which was updated several times thereafter. Currently, the most well known version is the MIRD Primer from 1991 [18.3]. The latest publication on the formalism was published in 2009 in MIRD Pamphlet No. 21 [18.4], which provides a notation meant to bridge the differences in the formalism used by the MIRD Committee and the International Commission on Radiological Protection (ICRP) [18.5]. The formalism presented in MIRD Pamphlet No. 21 [18.4] will be used here, although some references to the quantities and parameters used in the MIRD primer [18.3] will be made. All symbols, quantities and units are presented.

  16. Dosimetry of industrial sources

    Vega C, H.R.; Rodriguez J, R.; Manzanares A, E.; Hernandez V, R.; Ramirez G, J.; Rivera M, T.

    2007-01-01

    The gamma rays are produced during the disintegration of the atomic nuclei, its high energy allows them to cross thick materials. The capacity to attenuate a photons beam allows to determine the density, in line, of industrial interest materials as the mining. By means of two active dosemeters and a TLDs group (passive dosimetry) the dose rates of two sources of Cs-137 used for determining in line the density of mining materials were determined. With the dosemeters the dose levels in diverse points inside the grave that it harbors the sources and by means of calculations the isodoses curves were determined. In the phase of calculations was supposed that both sources were punctual and the isodose curves were calculated for two situations: naked sources and in their Pb packings. The dosimetry was carried out around two sources of 137 Cs. The measured values allowed to develop a calculation procedure to obtain the isodoses curves in the grave where the sources are installed. (Author)

  17. Clinical dosimetry using mosfets

    Ramani, Ramaseshan; Russell, Stephen; O'Brien, Peter

    1997-01-01

    Purpose: The use of metal oxide-silicon field effect transistors (MOSFETs) as clinical dosimeters is demonstrated for a number of patients with targets at different clinical sites. Methods and Materials: Commercially available MOSFETs were characterized for energy response, angular dependency of response, and effect of accumulated dose on sensitivity and some inherent properties of MOSFETs. The doses determined both by thermoluminescence dosimetry (TLD) and MOSFETs in clinical situation were evaluated and compared to expected doses determined by calculation. Results: It was observed that a standard calibration of 0.01 Gy/mV gave MOSFET determined doses which agreed with expected doses to within 5% at the 95% confidence limit for photon beams from 6 to 25 MV and electron beams from 5 to 14 MeV. An energy-dependent variation in response of up to 28% was observed between two orientations of a MOSFET. The MOSFET doses compared very well with the doses estimated by TLDs, and the patients tolerated MOSFETs very well. A standard deviation of 3.9% between expected dose and MOSFET determined dose was observed, while for TLDs the standard deviation was 5.1%. The advantages and disadvantages of using MOSFETs for clinical dosimetry are discussed in detail. Conclusion: It was concluded that MOSFETs can be used as clinical dosimeters and can be a good alternative to TLDs. However, they have limitations under certain clinical situations

  18. Development of the tool for generating ORIGEN2 library based on JENDL-3.2 for FBR

    Ohkawachi, Yasushi; Fukushima, Manabu

    1999-05-01

    ORIGEN2 is one of the most widely-used burnup analysis code in the world. This code has one-grouped cross section libraries compiled for various types of reactors. However, these libraries have some problems. One is that these libraries were developed from old nuclear data libraries (ENDF/B-IV,V) and the other is that core and fuel designs from which these libraries are generated do not match the current analysis. In order to solve the problems, analysis tool is developed for generating ORIGEN2 library from JENDL-3.2 considering multi-energy neutron spectrum. And eight new libraries are prepared using this tool for analysis of sodium-cooled FBR. These new libraries are prepared for eight kinds of cores in total. Seven of them are made by changing core size (small core - large core), fuel type (oxide, nitride, metal) and Pu vector as a parameter. The eighth one is a Pu burner core. Burnup calculation using both new and original libraries, shows large difference in buildup or depletion numbers of nuclides among the libraries. It is estimated that the analysis result is greatly influenced by the neutron spectrum which is used in collapse of cross section. By using this tool or new libraries, it seems to improve evaluation accuracy of buildup or depletion numbers of nuclides in transmutation research on FBR fuel cycle. (author)

  19. Reliability assessment of MVP-BURN and JENDL-4.0 related to nuclear transmutation of light platinum group elements

    Terashima Atsunori

    2017-01-01

    Full Text Available The Aprés ORIENT research program, as a concept of advanced nuclear fuel cycle, was initiated in FY2011 aiming at creating stable, highly-valuable elements by nuclear transmutation from ↓ssion products. In order to simulate creation of such elements by (n, γ reaction succeeded by β− decay in reactors, a continuous-energy Monte Carlo burnup calculation code MVP-BURN was employed. Then, it is one of the most important tasks to con↓rm the reliability of MVP-BURN code and evaluated neutron cross section library. In this study, both an experiment of neutron activation analysis in TRIGA Mark I reactor at University of California, Irvine and the corresponding burnup calculation using MVP-BURN code were performed for validation of the simulation on transmutation of light platinum group elements. Especially, some neutron capture reactions such as 102Ru(n, γ103Ru, 104Ru(n, γ105Ru, and 108Pd(n, γ109Pd were dealt with in this study. From a comparison between the calculation (C and the experiment (E about 102Ru(n, γ103Ru, the deviation (C/E-1 was signi↓cantly large. Then, it is strongly suspected that not MVP-BURN code but the neutron capture cross section of 102Ru belonging to JENDL-4.0 used in this simulation have made the big di↑erence as (C/E-1 >20%.

  20. Reliability assessment of MVP-BURN and JENDL-4.0 related to nuclear transmutation of light platinum group elements

    Terashima, Atsunori; Nilsson, Mikael; Ozawa, Masaki; Chiba, Satoshi

    2017-09-01

    The Aprés ORIENT research program, as a concept of advanced nuclear fuel cycle, was initiated in FY2011 aiming at creating stable, highly-valuable elements by nuclear transmutation from ↓ssion products. In order to simulate creation of such elements by (n, γ) reaction succeeded by β- decay in reactors, a continuous-energy Monte Carlo burnup calculation code MVP-BURN was employed. Then, it is one of the most important tasks to con↓rm the reliability of MVP-BURN code and evaluated neutron cross section library. In this study, both an experiment of neutron activation analysis in TRIGA Mark I reactor at University of California, Irvine and the corresponding burnup calculation using MVP-BURN code were performed for validation of the simulation on transmutation of light platinum group elements. Especially, some neutron capture reactions such as 102Ru(n, γ)103Ru, 104Ru(n, γ)105Ru, and 108Pd(n, γ)109Pd were dealt with in this study. From a comparison between the calculation (C) and the experiment (E) about 102Ru(n, γ)103Ru, the deviation (C/E-1) was signi↓cantly large. Then, it is strongly suspected that not MVP-BURN code but the neutron capture cross section of 102Ru belonging to JENDL-4.0 used in this simulation have made the big di↑erence as (C/E-1) >20%.

  1. Information from the Dosimetry Service

    2006-01-01

    Please note the following opening hours of the Service: From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  2. Foundations of ionizing radiation dosimetry

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  3. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  4. Skin dosimetry - radiological protection aspects of skin dosimetry

    Dennis, J.A.

    1991-01-01

    Following a Workshop in Skin Dosimetry, a summary of the radiological protection aspects is given. Aspects discussed include routine skin monitoring and dose limits, the need for careful skin dosimetry in high accidental exposures, techniques for assessing skin dose at all relevant depths and the specification of dose quantities to be measured by personal dosemeters and the appropriate methods to be used in their calibration. (UK)

  5. Evaluation and improvement of cross section accuracy for most important dosimetry reactions 27Al(n,p), 56Fe(n,p) and 237Np(n,f) including covariance data

    Zolotarev, K.I.

    2004-02-01

    New evaluations of cross sections and their uncertainties for dosimetry reactions 27 Al(n,p) , 56 Fe(n,p) and 237 Np(n,f) have been carried out in the frame work of IAEA Research Contract No. 11372/RB. Data files prepared for this reactions in the ENDF-6 format may be consider as candidates for the new International Reactor Dosimetry File: IRDF-2002. (author)

  6. Evaluation and improvement of cross section accuracy for most important dosimetry reactions 27Al(n,p), 56Fe(n,p) and 237Np(n,f) including covariance data

    Zolotarev, K I [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    2004-02-01

    New evaluations of cross sections and their uncertainties for dosimetry reactions {sup 27}Al(n,p) , {sup 56}Fe(n,p) and {sup 237}Np(n,f) have been carried out in the frame work of IAEA Research Contract No. 11372/RB. Data files prepared for this reactions in the ENDF-6 format may be consider as candidates for the new International Reactor Dosimetry File: IRDF-2002. (author)

  7. Alanine dosimetry for clinical applications. Proceedings

    Anton, M.

    2006-05-01

    The following topics are dealt with: Therapy level alanine dosimetry at the UK Nationational Physical Laboratory, alanine as a precision validation tool for reference dosimetry, composition of alanine pellet dosimeters, the angular dependence of the alanine ESR spectrum, the CIAE alanine dosimeter for radiotherapy level, a correction for temporal evolution effects in alanine dosimetry, next-generation services foe e-traceability to ionization radiation national standards, establishing e-traceability to HIST high-dose measurement standards, alanine dosimetry of dose delivery from clinical accelerators, the e-scan alanine dosimeter reader, alanine dosimetry at ISS, verification of the integral delivered dose for IMRT treatment in the head and neck region with ESR/alanine dosimetry, alanine dosimetry in helical tomotherapy beams, ESR dosimetry research and development at the University of Palermo, lithium formate as a low-dose EPR radiation dosimeter, sensitivity enhancement of alanine/EPR dosimetry. (HSI)

  8. Results of the dosimetry intercomparison

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  9. Fast neutron spectrometry and dosimetry

    Blaize, S.; Ailloud, J.; Mariani, J.; Millot, J.P.

    1958-01-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author) [fr

  10. Internal dosimetry technical basis manual

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.

  11. Internal dosimetry technical basis manual

    1990-01-01

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs

  12. Dosimetry systems for radiation processing

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  13. Dosimetry for radiation processing

    Kumar, A.; Reddy, A.R.

    1994-01-01

    The last few years have seen a significant increase in the use of ionising radiation in industrial processes and also international trade in irradiated products. With this, the demand for internationally accepted dosimetric techniques, accredited to international standards has also increased which is further stimulated by the emergence of ISO-9000 series of standards in industries. The present paper describes some of the important dosimetric techniques used in radiation processing, the role of IAEA in evolving internationally accepted standards and work carried out at the Defence Laboratories, Jodhpur in the development of a cheap, broad dose range and simple dosimeter for routine dosimetry. For this polyhydroxy alcohols viz., mannitol, sorbitol and inositol were studied using the spectrophotometric read out method. Out of the alcohols studied mannitol was found to be most promising covering a dose range of 0.01 kGy - 100 kGy. (author). 26 refs., 3 figs., 1 tab

  14. Dosimetry of fast neutrons

    Jahr, R.

    1975-03-01

    Following an explanation of the physical fundamentals of neutron dosimetry, the special needs in medicine and biology are gone into. It is shown that the dose equivalent used in radiation protection simplifies in an undue manner the complicated dependence of the biological effects. The reason for this is the fact that the RBE for heavy recoil nuclei, amongst others, depends on the energy and sort of particle, whereas it is approximately equal to one for electrons independent of the energy. It is thus necessary in the fields of biology and medicine to have additional information on energy spectra of the neutrons as well as of all charged secondary particles as a function of the position in the phantom. These are obtained partly by calculation and partly by special dosemeters. The accuracy achieved so far is 5%. (ORU/LH) [de

  15. Dosimetry of breast cancer

    Ramirez C, G; Restrepo, J; Aguirre, C A [Hospital Universitario del Valle, Cali (Colombia)

    1996-08-01

    The systemic therapy of breast cancer has also changed profoundly during the last 60 years, and in this time the integration of treatment modalities involve a major area of investigation. The dosimetry of breast cancer presents different complications which can range from the Physician`s handling of the neoplasia up to the simple aspects of physical simulation, contour design, radiation fields, irregular surfaces and computer programs containing mathematical equations which differ little or largely with the reality of the radiation distribution into the volume to be irradiated. We have studied the problem using two types of measurements to determine how the radiation distribution is in irregular surfaces, and designing an easier skill to be used with each patient, in order to optimize the treatment with respect to the simulation and verification process. (author). 7 refs.

  16. Radioiodotherapy: dosimetry planning

    Apyan, A.; Mileshin, O.; Klyopov, A.; Shishkanov, N.; Matusevich, E.; Roziev, A.

    2001-01-01

    The results of treatment of 142 case histories of 125 patients who had been treated with radioactive iodine at the Medical Radiological Research Center of Russian Academy of Medicine Sciences from 1983 to 1999 are given in the presentation. Among the patients, 35 cases of diffuse toxic goiter with signs of thyrotoxicosis of a mild degree, 25 cases of Diffuse toxic goiter with severe thyrotoxicosis, 6 cases of differentiated thyroid cancer with metastases to lymph-nodes of the neck, 30 cases of thyroid cancer with metastases to lymph-nodes of the neck and lung and 1 case of thyroid cancer with metastases to bones were diagnosed. This paper gives recommendations for individual dosimetry planning for radioiodine-therapy. (authors)

  17. Advances in electron dosimetry

    Harder, D.

    1980-04-01

    Starting from the two most important interactions of electrons with matter, energy loss and scattering, a review is given of a number of effects which are important in electron dosimetry. For determining the absorbed dose in a phantom by means of ionization chambers, imformation is required on the electron spectrum at the location of the measurement, on the stopping powers of different materials and on disturbances such as the displacement of the effective point of measurements from the centre of the chamber. By means of figures and photographs of electron traces in bubble chambers, the origin of the formation of the absorbed dose maximum in a phantom is explained. It is shown, how by multiple scattering, the similarity of dose distributions in different media can be explained and how by Monte-Carlo calculations absorbed dose distributions in the surroundings of inhomogeneities (e.g. cavities) in a phantom can be determined. (orig.) [de

  18. The Vinca dosimetry experiment

    NONE

    1962-03-15

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States.

  19. The Vinca dosimetry experiment

    1962-03-01

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States

  20. Dosimetry in radionuclide therapy

    Riccabona, G.

    2001-01-01

    While it is known that therapeutic effects of radionuclides are due to absorbed radiation dose and to radiosensitivity, individual dosimetry in 'Gy' is practiced rarely in clinical Nuclear Medicine but 'doses' are described in 'mCi' or 'MBq', which is only indirectly related to 'Gy' in the target. To estimate 'Gy', the volume of the target, maximum concentration of the radiopharmaceutical in it and residence time should be assessed individually. These parameters can be obtained usually only with difficulty, involving possibly also quantitative SPET or PET, modern imaging techniques (sonography, CT, MRT), substitution of y- or positron emitting radiotracers for β - emitting radiopharmaceuticals as well as whole-body distribution studies. Residence time can be estimated by obtaining data on biological half-life of a comparable tracer and transfer of these data in the physical characteristics of the therapeutic agent. With all these possibilities for gross dosimetry the establishment of a dose-response-relation should be possible. As distribution of the radiopharmaceutical in lesions is frequently inhomogenous and microdosimetric conditions are difficult to assess in vivo as yet, it could be observed since decades that empirically set, sometimes 'fixed' doses (mCi or MBq) can also be successful in many diseases. Detailed dosimetric studies, however, are work- and cost-intensive. Nevertheless, one should be aware at a time when more sophisticated therapeutic possibilities in Nuclear Medicine arise, that we should try to estimate radiation dose (Gy) in our new methods even as differences in individual radiosensitivity cannot be assessed yet and studies to define individual radiosensitivity in lesions should be encouraged. (author)

  1. Dosimetry in intravascular brachytherapy

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  2. High energy dosimetry

    Ruhm, W.

    2010-01-01

    Full text: Currently, quantification of doses from high-energy radiation fields is a topical issue. This is so because high-energy neutrons play an important role for radiation exposure of air crew members and personnel outside the shielding of ion therapy facilities. In an effort to study air crew exposure from cosmic radiation in detail, two Bonner Sphere Spectrometers (BSSs) have recently been installed to measure secondary neutrons from cosmic radiation, one at the environmental research station 'Schneefernerhaus' at an altitude of 2650 m on the Zugspitze mountain, Germany, the other at the Koldewey station close to the North Pole on Spitsbergen. Based on the measured neutron fluence distributions and on fluence-to-dose conversion coefficients, mean ambient dose equivalent rate values of 75.0 ± 2.9 nSv/h and 8.7 ± 0.6 nSv/h were obtained for October 2008, respectively. Neutrons with energies above about 20 MeV contribute about 50% to dose, at 2650 m. Ambient dose equivalent rates measured by means of a standard rem counter and an extended rem counter at the Schneefernerhaus confirm this result. In order to study the response of state-of-the-art radiation instrumentation in such a high-energy radiation field, a benchmark exercise that included both measurements in and simulation of the stray neutron radiation field at the high-energy particle accelerator at GSI, Germany, were performed. This CONRAD (COordinated Network for RAdiation Dosimetry) project was funded by the European Commission, and the organizational framework was provided by the European Radiation Dosimetry Group, EURADOS. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers suggest the neutron fluence distributions to be very similar to those of secondary neutrons from cosmic radiation. The results of this intercomparison exercise in terms of ambient dose equivalent are also discussed

  3. Fifth international radiopharmaceutical dosimetry symposium

    Watson, E.E.; Schlafke-Stelson, A.T.

    1992-05-01

    This meeting was held to exchange information on how to get better estimates of the radiation absorbed dose. There seems to be a high interest of late in patient dosimetry; discussions were held in the light of revised risk estimates for radiation. Topics included: Strategies of Dose Assessment; Dose Estimation for Radioimmunotherapy; Dose Calculation Techniques and Models; Dose Estimation for Positron Emission Tomography (PET); Kinetics for Dose Estimation; and Small Scale Dosimetry and Microdosimetry. (VC)

  4. Dosimetry of high energy radiation

    Sahare, P D

    2018-01-01

    High energy radiation is hazardous to living beings and a threat to mankind. The correct estimation of the high energy radiation is a must and a single technique may not be very successful. The process of estimating the dose (the absorbed energy that could cause damages) is called dosimetry. This book covers the basic technical knowledge in the field of radiation dosimetry. It also makes readers aware of the dangers and hazards of high energy radiation.

  5. Hanford internal dosimetry program manual

    Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.; Aldridge, T.L.

    1989-10-01

    This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs

  6. Titanium-II: an evaluated nuclear data file

    Philis, C.; Howerton, R.; Smith, A.B.

    1977-06-01

    A comprehensive evaluated nuclear data file for elemental titanium is outlined including definition of the data base, the evaluation procedures and judgments, and the final evaluated results. The file describes all significant neutron-induced reactions with elemental titanium and the associated photon-production processes to incident neutron energies of 20.0 MeV. In addition, isotopic-reaction files, consistent with the elemental file, are separately defined for those processes which are important to applied considerations of material-damage and neutron-dosimetry. The file is formulated in the ENDF format. This report formally documents the evaluation and, together with the numerical file, is submitted for consideration as a part of the ENDF/B-V evaluated file system. 20 figures, 9 tables

  7. Internal dosimetry, past and future

    Johnson, J.R.

    1989-03-01

    This paper is a review of the progress in the dosimetry of internally deposited radionuclides (internal dosimetry) since World War II. Previous to that, only naturally occurring radionuclides were available and only a limited number of studies of biokinetics and dosimetry were done. The main radionuclides studied were 226 Ra, 228 Ra, and 224 Ra but natural uranium was also studied mainly because of its toxic effect as a heavy metal, and not because it was radioactive. The effects of 226 Ra in bone, mainly from the radium dial painters, also formed the only bases for the radiotoxicity of radionuclides in bone for many years, and it is still, along with 224 Ra, the main source of information on the effects of alpha emitters in bone. The publications of the International Commission on Radiological Protection that have an impact on internal dosimetry are used as mileposts for this review. These series of publications, more than any other, represent a broad consensus of opinion within the radiation protection community at the time of their publication, and have formed the bases for radiation protection practice throughout the world. This review is not meant to be exhaustive; it is meant to be a personnel view of the evolution of internal dosimetry, and to present the author's opinion of what the future directions in internal dosimetry will be. 39 refs., 2 tabs

  8. Calculation of dosimetry parameters for fast neutron radiotherapy

    Wells, A.H.

    1978-05-01

    A computer simulation of the interactions of 50 MeV d/sup +/ on Be and 42 MeV p/sup +/ on Be neutron spectra with ICRU muscle tissue and Shonka A-150 tissue equivalent plastic was performed to allow computation of the charged particle spectra that result. Nuclear data were obtained from the Evaluated Nuclear Data File (ENDF) whenever possible and from the Intranuclear Cascade and Evaporation models otherwise. The dosimetry parameters calculated are: the kerma ratio, K/sub A-150//K/sub tissue/; the energy required to form an ion pair, W; and the stopping power ratio, S/sub g//sup W/.

  9. Calculation of dosimetry parameters for fast neutron radiotherapy

    Wells, A.H.

    1978-05-01

    A computer simulation of the interactions of 50 MeV d + on Be and 42 MeV p + on Be neutron spectra with ICRU muscle tissue and Shonka A-150 tissue equivalent plastic was performed to allow computation of the charged particle spectra that result. Nuclear data were obtained from the Evaluated Nuclear Data File (ENDF) whenever possible and from the Intranuclear Cascade and Evaporation models otherwise. The dosimetry parameters calculated are: the kerma ratio, K/sub A-150//K/sub tissue/; the energy required to form an ion pair, W; and the stopping power ratio, S/sub g//sup W/

  10. 11. International conference on solid radiation dosimetry

    Krylova, I.V.

    1996-01-01

    The main problems discussed during the international conference on solid radiation dosimetry which took place in June 1995 in Budapest are briefly considered. These are the basic physical processes, materials applied for dosimetry, special techniques, personnel monitoring, monitoring of environmental effects, large-dose dosimetry, clinic dosimetry, track detector used for dosimetry, dosimetry in archaeology and geology, equipment and technique for dosimetric measurements. The special attention was paid to superlinearity in the TLD-100 (LiF, Mg, Ti) response function when determining doses of gamma radiation, heavy charged particles, low-energy particle fluxes in particular. New theoretical models were considered

  11. File sharing

    van Eijk, N.

    2011-01-01

    File sharing’ has become generally accepted on the Internet. Users share files for downloading music, films, games, software etc. In this note, we have a closer look at the definition of file sharing, the legal and policy-based context as well as enforcement issues. The economic and cultural

  12. Radiotherapy gel dosimetry

    Baldock, C.

    2002-01-01

    shapes and sizes while sparing normal tissue. The situation is further complicated if the normal tissues are critical organs or are particularly sensitive to radiation. Radiotherapy techniques employed to obtain a closer conformation of the dose distribution to the tumour volume are referred to as conformal radiotherapy techniques. The clinical implementation of conformal therapy has been delayed by limitations in the verification of conformal dose distributions calculated by treatment planning systems prior to the irradiation of the patient and the verification of complex treatments during its delivery to the patient. There are several aspects of conformal therapy that complicate dose verification. To achieve the dose distributions conforming to complex 3D volumes, high dose gradients arise in the treatment volume. Further, overdose or underdose regions can exist when separate radiation fields are used to deliver additional radiation. These aspects require that practical dose measurement (dosimetry) techniques be able to integrate dose over time and easily measure dose distributions in 3D with high spatial resolution. Traditional dosimeters, such as ion chambers, thermoluminescent dosimeters and radiographic film do not fulfil these requirements. Novel gel dosimetry techniques are being developed in which dose distributions can potentially be determined in vitro in 3D using anthropomorphic phantoms to simulate a clinically irradiated situation. As long ago as the 1950's, radiation-induced colour change in dyes was used to investigate radiation doses in gels. It was subsequently shown that radiation induced changes in nuclear magnetic resonance (NMR) relaxation properties of gels infused with conventional Fricke dosimetry solutions could be measured using magnetic resonance imaging (MRI). In Fricke gels, Fe 2+ ions in ferrous sulphate solutions are usually dispersed throughout a gelatin, agarose or PVA matrix. Radiation-induced changes in the dosimeters are considered to

  13. Quantitative evaluation of patient-specific quality assurance using online dosimetry system

    Jung, Jae-Yong; Shin, Young-Ju; Sohn, Seung-Chang; Min, Jung-Whan; Kim, Yon-Lae; Kim, Dong-Su; Choe, Bo-Young; Suh, Tae-Suk

    2018-01-01

    In this study, we investigated the clinical performance of an online dosimetry system (Mobius FX system, MFX) by 1) dosimetric plan verification using gamma passing rates and dose volume metrics and 2) error-detection capability evaluation by deliberately introduced machine error. Eighteen volumetric modulated arc therapy (VMAT) plans were studied. To evaluate the clinical performance of the MFX, we used gamma analysis and dose volume histogram (DVH) analysis. In addition, to evaluate the error-detection capability, we used gamma analysis and DVH analysis utilizing three types of deliberately introduced errors (Type 1: gantry angle-independent multi-leaf collimator (MLC) error, Type 2: gantry angle-dependent MLC error, and Type 3: gantry angle error). A dosimetric verification comparison of physical dosimetry system (Delt4PT) and online dosimetry system (MFX), gamma passing rates of the two dosimetry systems showed very good agreement with treatment planning system (TPS) calculation. For the average dose difference between the TPS calculation and the MFX measurement, most of the dose metrics showed good agreement within a tolerance of 3%. For the error-detection comparison of Delta4PT and MFX, the gamma passing rates of the two dosimetry systems did not meet the 90% acceptance criterion with the magnitude of error exceeding 2 mm and 1.5 ◦, respectively, for error plans of Types 1, 2, and 3. For delivery with all error types, the average dose difference of PTV due to error magnitude showed good agreement between calculated TPS and measured MFX within 1%. Overall, the results of the online dosimetry system showed very good agreement with those of the physical dosimetry system. Our results suggest that a log file-based online dosimetry system is a very suitable verification tool for accurate and efficient clinical routines for patient-specific quality assurance (QA).

  14. Sensitivity Study for the Keff of a Lead Based ADS on the Cross Sections Evaluations: ENDFB-6.4 and JENDL-3.2

    Embid, M.; Fernandez, R.; Gonzalez, E.

    1998-05-01

    In any simulation of the neutronic behaviour of a nuclear system, the accuracy of the results is limited by the precision of the nuclear databases used, in particular for the cross sections. In the study of Accelerator Driven System (ADS) for transmutation appear aspects new for the nuclear systems. The best example is the very important role played by unusual isotopes, particularly lead and some transuranics. In the present paper, the results of a comparison of the predicted behaviour of one Th-TRU and lead based ADS according to the ENDFB-6.4 or the JENDL-3.2 databases will be presented

  15. Computational analysis of neutronic parameters for TRIGA Mark-II research reactor using evaluated nuclear data libraries ENDF/B-VII.0 and JENDL-3.3

    Altaf, M.H.; Badrun, N.H.; Chowdhury, M.T.

    2015-01-01

    Highlights: • SRAC-PIJ code and SRAC-CITATION have been utilized to model the core. • Most of the simulated results show no significant differences with references. • Thermal peak flux varies a bit due to up condition of TRIGA. • ENDF/B-VII.0 and JENDL-3.3 libraries perform well for neutronics analysis of TRIGA. - Abstract: Important kinetic parameters such as effective multiplication factor, k eff , excess reactivity, neutron flux and power distribution, and power peaking factors of TRIGA Mark II research reactor in Bangladesh have been calculated using the comprehensive neutronics calculation code system SRAC 2006 with the evaluated nuclear data libraries ENDF/B-VII.0 and JENDL-3.3. In the code system, PIJ code was employed to obtain cross section of the core cells, followed by the integral calculation of neutronic parameters of the reactor conducted by CITATION code. All the analyses were performed using the 7-group macroscopic cross section library. Results were compared to the experimental data, the safety analysis report (SAR) of the reactor provided by General Atomic as well as to the simulated values by numerically benchmarked MCNP4C, WIMS-CITATION and SRAC-CITATION codes. The maximum power densities at the hot spot were found to be 169.7 W/cc and 170.1 W/cc for data libraries ENDF/B-VII.0 and JENDL-3.3, respectively. Similarly, the total peaking factors based on ENDF/B-VII.0 and JENDL-3.3 were calculated as 5.68 and 5.70, respectively, which were compared to the original SAR value of 5.63, as well as to MCNP4C, WIMS-CITATION and SRAC-CITATION results. It was found in most cases that the calculated results demonstrate a good agreement with our experiments and published works. Therefore, this analysis benchmarks the code system and will be helpful to enhance further neutronics and thermal hydraulics study of the reactor

  16. Comparisons of the MCNP criticality benchmark suite with ENDF/B-VI.8, JENDL-3.3, and JEFF-3.0

    Kim, Do Heon; Gil, Choong-Sup; Kim, Jung-Do; Chang, Jonghwa

    2003-01-01

    A comparative study has been performed with the latest evaluated nuclear data libraries ENDF/B-VI.8, JENDL-3.3, and JEFF-3.0. The study has been conducted through the benchmark calculations for 91 criticality problems with the libraries processed for MCNP4C. The calculation results have been compared with those of the ENDF60 library. The self-shielding effects of the unresolved-resonance (UR) probability tables have also been estimated for each library. The χ 2 differences between the MCNP results and experimental data were calculated for the libraries. (author)

  17. Solution of the CSEWG - STD-9 shielding standard problem using the coupled systems NJOY/AMPX-II and the JENDL-3 library

    Mendoncca, A.G.; Santos, A dos

    1993-01-01

    The CSEWG STD-9 benchmark has been analyzed to evaluate the shielding and out-of-core methodologies using the coupled systems NJOY/AMPX-II and the JENDL-3 library as well as the DOT 3.5 for the transport calculations. Good agreement between calculated and experimental values for the spatial and energetic neutron flux distributions have been found. However, the results for the reaction rates of the activation foils were discrepant even though for same cases they come into a good agreement. (author)

  18. Development of the fast reactor group constant set JFS-3-J3.2R based on the JENDL-3.2

    Chiba, G

    2002-01-01

    It is reported that the fast reactor group constant set JFS-3-J3.2 based on the newest evaluated nuclear data library JENDL3.2 has a serious error in the process of applying the weighting function. As the error affects greatly nuclear characteristics, and a corrected version of the reactor constant set, JFS-3-J3.2R, was developed, as well as lumped FP cross sections. The use of JFS-3-J3.2R improves the results of analyses especially on sample Doppler reactivity and reaction rate in the blanket region in comparison with those obtained using the JFS-3-J3.2.

  19. Evaluation of nuclear data for neutron dosimetry

    Tardelli, Tiago Cardoso

    2013-01-01

    Absorbed dose and Effective dose are usually calculated using radiation transport computer codes. The quality of the calculations of absorbed dose depends on nuclear data utilized, however, there are rare information about the differences in dose caused by the use of different libraries. The objective of this study is to compare dose values obtained using different nuclear data libraries due to external source of neutrons in the energy range from 10-11 to 20 MeV. The nuclear data libraries used are: JENDL 4.0, JEFF 3.3.1 and ENDF/B.VII. Dose calculations were carried out with the MCNPX code considering the anthropomorphic ICRP 110 model. The differences in the absorbed dose values using JEFF 3.3.1 and ENDF/B.VII libraries are small, around 1%, but the results obtained with JENDL 4.0 presented differences up to 85% compared to ENDF and JEFF results. Differences in effective dose values are around 1.5% between ENDF and JEFF and 11% between ENDF/B.VII and JENDL 4.0. (author)

  20. Characterising an aluminium oxide dosimetry system.

    Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor

    2015-09-01

    In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.

  1. Dosimetry in nuclear power plants

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  2. Neutron personnel dosimetry

    Griffith, R.V.

    1982-01-01

    The measurement of neutron exposures to personnel is an issue that has received increased attention in the last few years. It is important to consider key aspects of the whole dosimetry system when developing dose estimates. This begins with selection of proper dosimeters and survey instruments, and extends through the calibration methods. One must match the spectral response and sensitivity of the dosimeter to the spectral characteristics of the neutron fields. Threshold detectors that are insensitive to large fractions of neutrons in the lower energy portion of reactor spectra should be avoided. Use of two or more detectors with responses that complement each other will improve measurement quality. It is important to understand the spectral response of survey instruments, so that spectra which result in significant overresponse do not lead to overestimation of dose. Calibration sources that do not match operational field spectra can contribute to highly erroneous results. In those situations, in-field calibration techniques should be employed. Although some detection developments have been made in recent years, a lot can be done with existing technology until fully satisfactory, long term solutions are obtained

  3. Fast neutron dosimetry

    DeLuca, P.M. Jr.; Pearson, D.W.

    1991-01-01

    During 1988--1990 the magnetic resonance dosimetry project was completed, as were the 250 MeV proton shielding measurements. The first cellular experiment using human cells in vitro at the 1 GeV electron storage ring was also accomplished. More detail may be found in DOE Report number-sign DOE/EV/60417-002 and the open literature cited in the individual progress subsections. We report Kinetic Energy Released in Matter (KERMA), factor measurements in several elements of critical importance to neutron radiation therapy and radiation protection for space habitation and exploration for neutron energies below 30 MeV. The results of this effort provide the only direct measurements of the oxygen and magnesium kerma factors above 20 MeV neutron energy, and the only measurements of the iron kerma factor above 15 MeV. They provide data of immediate relevance to neutron radiotherapy and impose strict criteria for normalizing and testing nuclear models used to calculate kerma factors at higher neutron energies

  4. Dosimetry in radioisotope placentography

    Sastry, K.G.K.; Reddy, A.R.; Nagaratnam, A.

    1976-01-01

    Radionuclide investigation of the placenta is being widely used in recent years for the diagnosis and management of vaginal bleeding in the third trimester of pregnancy. One is, therefore, concerned about the radiation exposure to the foetus during such procedures. In the present communication a precise method of estimation of radiation doses is presented. A concept termed 'effective absorbed dose constant' is utilized to enable the absorbed fractions and equilibrium absorbed dose constants to be more easily employed in radiation dose estimations. Tables of the effective absorbed dose constants for radionuclides like 131 I, 123 I, sup(113m)Tc, sup(99m)Tc, 67 Ga, and 51 Cr, are given for different masses and shapes. Masses of different organs of both mother and foetus at different periods of pregnancy and the biological turnover data for different radiopharmaceuticals are reviewed and typical values are presented. Radiation doses to different organs of both mother and foetus at the 30th week of pregnancy are finally estimated for 131 I-HSA, 123 I-SHA, sup(99m)Tc-HSA and sup(113m)In-chloride. The advantage of the effective absorbed dose constants in radiation dosimetry in general is discussed. The relative merits of different radiopharmaceuticals for placental investigations are brought out in comparison with antenatal pelvimetric and abdominal X-ray investigations, from the point of view of radiation doses. (author)

  5. Miniature semiconductor detectors for in vivo dosimetry

    Rosenfeld, A. B.; Cutajar, D.; Lerch, M. L. F.; Takacs, G.; Cornelius, I. M.; Yudelev, M.; Zaider, M.

    2006-01-01

    Silicon mini-semiconductor detectors are found in wide applications for in vivo personal dosimetry and dosimetry and Micro-dosimetry of different radiation oncology modalities. These applications are based on integral and spectroscopy modes of metal oxide semiconductor field effect transistor and silicon p-n junction detectors. The advantages and limitations of each are discussed. (authors)

  6. Fundamentals of x-ray dosimetry

    Roesch, W.C.

    1976-01-01

    Fundamental information about x-ray dosimetry is presented. Definitions are given and expanded on for dose, absorbed dose including microdosimetry, radiation physics (properties of the radiation that are important to dosimetry), and dosimetry (how the properties are dealt with in determining dose). 5 figs, 12 refs

  7. Information from the Dosimetry Service

    2006-01-01

    Please note the following opening hours of the Service: In June: Every morning from 8:30 to 12:00 In July: Mondays, Wednesdays and Fridays from 8:30 to 11:30 Closed all day on Tuesdays and Thursdays From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  8. Fundamentals of Dosimetry. Chapter 3

    Yoshimura, E. M. [Universidade de São Paulo, São Paulo (Brazil)

    2014-09-15

    Determination of the energy imparted to matter by radiation is the subject of dosimetry. The energy deposited as radiation interacts with atoms of the material, as seen in the previous chapter. The imparted energy is responsible for the effects that radiation causes in matter, for instance, a rise in temperature, or chemical or physical changes in the material properties. Several of the changes produced in matter by radiation are proportional to the absorbed dose, giving rise to the possibility of using the material as the sensitive part of a dosimeter. Also, the biological effects of radiation depend on the absorbed dose. A set of quantities related to the radiation field is also defined within the scope of dosimetry. It will be shown in this chapter that, under special conditions, there are simple relations between dosimetric and field description quantities. Thus, the framework of dosimetry is the set of physical and operational quantities that are studied in this chapter.

  9. External audit in radiotherapy dosimetry

    Thwaites, D.I.; Western General Hospital, Edinburgh

    1996-01-01

    Quality audit forms an essential part of any comprehensive quality assurance programme. This is true in radiotherapy generally and in specific areas such as radiotherapy dosimetry. Quality audit can independently test the effectiveness of the quality system and in so doing can identify problem areas and minimize their possible consequences. Some general points concerning quality audit applied to radiotherapy are followed by specific discussion of its practical role in radiotherapy dosimetry, following its evolution from dosimetric intercomparison exercises to routine measurement-based on-going audit in the various developing audit networks both in the UK and internationally. Specific examples of methods and results are given from some of these, including the Scottish+ audit group. Quality audit in radiotherapy dosimetry is now well proven and participation by individual centres is strongly recommended. Similar audit approaches are to be encouraged in other areas of the radiotherapy process. (author)

  10. Dosimetry standards for radiation processing

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  11. 'Hot particle' intercomparison dosimetry

    Kaurin, D.G.L.; Baum, J.W.; Charles, M.W.; Darley, D.P.J.; Durham, J.S.; Scannell, M.J.; Soares, C.G.

    1996-01-01

    Dosimetry measurements of four 'hot particles' were made at different density thickness values using five different methods. The hot particles had maximum dimensions of 650 μm and maximum beta energies of 0.97, 046, 0.36, and 0.32 MeV. Absorbers were used to obtain the dose at different depths for each dosimeter. Measurements were made using exoelectron dosimeters, an extrapolation chamber, NE Extremity Tape Dosimeters (tm), Eberline RO-2 and RO-2A survey meters, and two sets of GafChromic (tm) dye film with each set read out at a different institution. From these results the dose was calculated averaged over 1 cm 2 of tissue at 18, 70, 125, and 400 μm depth. Comparisons of tissue-dose averaged over 1 cm 2 for 18, 70, and 125 μm depth based on interpolated measured values, were within 30% for the GafChromic (tm) dye film, extrapolation chamber, NE Extremity Tape Dosimeters (tm), and Eberline RO-2 and 2A (tm) survey meters except for the hot particle with 0.46 MeV maximum beta energy. The results for this source showed differences of up to 60%. The extrapolation chamber and NE Extremity Tape dosimeters under-responded for measurements at 400 μm by about a factor of 2 compared with the GafChromic dye films for two hot particles with maximum beta energy of 0.32 and 0.36 MeV which each emitted two 100% 1 MeV photons per disintegration. Tissue doses determined using exoelectron dosimeters were a factor of 2 to 5 less than those determined using other dosimeters, possibly due to failures of the equipment. (author)

  12. Personal dosimetry and information platforms

    Sanchez Hidalgo, M.; Galan Montenegro, P.; Bodineau Gil, C.; Hernandez Rodriguez, R.; Jimenez Nartin, A.; Cano Sanchez, J. J.

    2011-01-01

    One question often raised by the hospital personnel dosimetry is the high incidence in the no monthly turnover of dosimeters, which is currently a high number of administrative dose assignments. The high number of workers with personal dosimetry and in many cases, the dispersion of workplaces makes it impossible to personalized management. To make a more direct and personal, and transmit information quickly and with guaranteed reception, has developed and implemented a system of personalized dosimetric information through messaging Short Message Service (SMS) and access to the history of dosimetric dosimetric and management through web space Service Hospital Radio physics.

  13. External dosimetry sources and shielding

    Calisto, Washington

    1994-01-01

    A definition of external dosimetry r external sources dosimetry,physical and mathematical treatment of the interaction of gamma radiation with a minimal area in that direction. Concept of attenuation coefficient, cumulated effect by polyenergetic sources, exposition rate, units, cumulated dose,shielding, foton shielding, depth calculation, materials used for shielding.Beta shielding, consideration of range and maximum β energy , low stopping radiation by use of low Z shielding. Tables for β energy of β emitters, I (tau) factor, energy-range curves for β emitters in aqueous media, gamma attenuation factors for U, W and Pb. Y factor for bone tissue,muscle and air, build-up factors

  14. Characterization of internal dosimetry practices

    Traub, R.J.; Heid, K.R.; Mann, J.C.

    1983-01-01

    Current practices in internal dosimetry at DOE facilities were evaluated with respect to consistency among DOE Contractors. All aspects of an internal dosimetry program were addressed. Items considered include, but are not necessarily limited to, record systems and ease of information retrieval; ease of integrating internal dose and external dose; modeling systems employed, including ability to modify models depending on excretion data, and verification of computer codes utilized; bioassay procedures, including quality control; and ability to relate air concentration data to individual workers and bioassay data. Feasibility of uranium analysis in solution by laser fluorescence excitation at uranium concentrations of one part per billion was demonstrated

  15. Information from the Dosimetry Service

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 to 12.00 and is closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  16. Information from the Dosimetry Service

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 - 12.00, and closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  17. Calorimetric dosimetry of reactor radiation

    Radak, B.; Markovic, V.; Draganic, I.

    1961-01-01

    Calorimetric dosimetry of reactor radiation is relatively new reactor dosimetry method and the number of relevant papers is rather small. Some difficulties in applying standard methods (chemical dosemeters, ionization chambers) exist because of the complexity of radiation. In general application of calorimetric dosemeters for measuring absorbed doses is most precise. In addition to adequate choice of calorimetric bodies there is a possibility of determining the yields of each component of the radiation mixture in the total absorbed dose. This paper contains a short review of the basic calorimetry methods and some results of measurements at the RA reactor in Vinca performed by isothermal calorimeter [sr

  18. Radiation dosimetry and radiation biophysics

    Anon.

    1981-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with the design and measurement of physical parameters used in theory or to support biological experiments. The radiation biophysics program tests and uses the theoretical developments for experimental design, and provides information for further theoretical development through experiments on cellular systems

  19. Radiation dosimetry and radiation biophysics

    Anon.

    1979-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with design and measurement of those physical parameters used in the theory or to support biological experiments. The radiation biophysics program tests and makes use of the theoretical developments for experimental design. Also, this program provides information for further theoretical development through experiments on cellular systems

  20. Validation of the Continuous-Energy Monte Carlo Criticality-Safety Analysis System MVP and JENDL-3.2 Using the Internationally Evaluated Criticality Benchmarks

    Mitake, Susumu

    2003-01-01

    Validation of the continuous-energy Monte Carlo criticality-safety analysis system, comprising the MVP code and neutron cross sections based on JENDL-3.2, was examined using benchmarks evaluated in the 'International Handbook of Evaluated Criticality Safety Benchmark Experiments'. Eight experiments (116 configurations) for the plutonium solution and plutonium-uranium mixture systems performed at Valduc, Battelle Pacific Northwest Laboratories, and other facilities were selected and used in the studies. The averaged multiplication factors calculated with MVP and MCNP-4B using the same neutron cross-section libraries based on JENDL-3.2 were in good agreement. Based on methods provided in the Japanese nuclear criticality-safety handbook, the estimated criticality lower-limit multiplication factors to be used as a subcriticality criterion for the criticality-safety evaluation of nuclear facilities were obtained. The analysis proved the applicability of the MVP code to the criticality-safety analysis of nuclear fuel facilities, particularly to the analysis of systems fueled with plutonium and in homogeneous and thermal-energy conditions

  1. Alanine EPR dosimetry of therapeutic irradiators

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  2. Benchmarking ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1 with MCNP6

    Marck, Steven C. van der

    2012-01-01

    Recent releases of three major world nuclear reaction data libraries, ENDF/B-VII.1, JENDL-4.0, and JEFF-3.1.1, have been tested extensively using benchmark calculations. The calculations were performed with the latest release of the continuous energy Monte Carlo neutronics code MCNP, i.e. MCNP6. Three types of benchmarks were used, viz. criticality safety benchmarks, (fusion) shielding benchmarks, and reference systems for which the effective delayed neutron fraction is reported. For criticality safety, more than 2000 benchmarks from the International Handbook of Criticality Safety Benchmark Experiments were used. Benchmarks from all categories were used, ranging from low-enriched uranium, compound fuel, thermal spectrum ones (LEU-COMP-THERM), to mixed uranium-plutonium, metallic fuel, fast spectrum ones (MIX-MET-FAST). For fusion shielding many benchmarks were based on IAEA specifications for the Oktavian experiments (for Al, Co, Cr, Cu, LiF, Mn, Mo, Si, Ti, W, Zr), Fusion Neutronics Source in Japan (for Be, C, N, O, Fe, Pb), and Pulsed Sphere experiments at Lawrence Livermore National Laboratory (for 6 Li, 7 Li, Be, C, N, O, Mg, Al, Ti, Fe, Pb, D2O, H2O, concrete, polyethylene and teflon). The new functionality in MCNP6 to calculate the effective delayed neutron fraction was tested by comparison with more than thirty measurements in widely varying systems. Among these were measurements in the Tank Critical Assembly (TCA in Japan) and IPEN/MB-01 (Brazil), both with a thermal spectrum, two cores in Masurca (France) and three cores in the Fast Critical Assembly (FCA, Japan), all with fast spectra. The performance of the three libraries, in combination with MCNP6, is shown to be good. The results for the LEU-COMP-THERM category are on average very close to the benchmark value. Also for most other categories the results are satisfactory. Deviations from the benchmark values do occur in certain benchmark series, or in isolated cases within benchmark series. Such

  3. Monte Carlo analysis of KRITZ-2 critical benchmarks on the reactivity temperature coefficient using ENDF/B-VII.1 and JENDL-4.0 nuclear data libraries

    El Ouahdani, S.; Boukhal, H.; Erradi, L.; Chakir, E.; El Bardouni, T.; Hajjaji, O.; Boulaich, Y.; Benaalilou, K.; Kaddour, M.

    2016-01-01

    Highlights: • A set of KRITZ-2 experiments with UO 2 and MOX LWR lattices, at room and elevated temperatures, have been analysed using the MCNP6.1 code with the libraries: JENDL-4 and ENDF/B-VII.1. • The detailed comparisons of the calculations and measurements demonstrate a good agreement between calculations and measurements. • To investigate better the influence of cross sections differences on the reactivity temperature coefficient, we break it down into its components using a pin cell model. - Abstract: A set of KRITZ-2 experiments light water moderated lattices with uranium oxide and mixed-oxide fuel rods, at room and elevated temperatures, performed in the early 1970’s have been assessed. Using the MCNP6.1 code with the most recent cross section libraries: JENDL-4 and ENDF/B-VII.1, the critical experiments KRITZ: 2-1, KRITZ: 2-13, and KRITZ: 2-19 achieved in the Sweden reactor KRITZ were analyzed. We have used the ENDF/B-VII.1 data provided with the MCNP6.1.1 version in ACE format and the Makxsf utility to handle the data in the specific temperatures not available in the MCNP6.1.1 original data. The JENDL-4 evaluations were processed using NJOY99 (update 364) to the temperatures of interest. The detailed comparisons of the calculated and measured (Benchmark, 2005) effective multiplication factors and pin power distributions for UO2 and MOX fuelled cores presented in this work demonstrate a good agreement between calculation and measurements. The maximum deviation of the calculation from the experimental data for k eff , is 0.58% (absolute value) obtained for the KRITZ 2:1 at 248.5 °C using ENDF/B-VII.1 data. To investigate better the influence of cross sections differences on the reactivity and temperature coefficient, we break down the infinite multiplication factor into its components using a pin cell model. Using this simple model we evaluated the temperature effect on the infinite multiplication factor and the effect on its components. We have

  4. US Army Radiological Bioassay and Dosimetry: The RBD software package

    Eckerman, K.F.; Ward, R.C.; Maddox, L.B.

    1993-01-01

    The RBD (Radiological Bioassay and Dosimetry) software package was developed for the U. S. Army Material Command, Arlington, Virginia, to demonstrate compliance with the radiation protection guidance 10 CFR Part 20 (ref. 1). Designed to be run interactively on an IBM-compatible personal computer, RBD consists of a data base module to manage bioassay data and a computational module that incorporates algorithms for estimating radionuclide intake from either acute or chronic exposures based on measurement of the worker's rate of excretion of the radionuclide or the retained activity in the body. In estimating the intake,RBD uses a separate file for each radionuclide containing parametric representations of the retention and excretion functions. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent. For a given nuclide, if measurements exist for more than one type of assay, an auxiliary module, REPORT, estimates the intake by applying weights assigned in the nuclide file for each assay. Bioassay data and computed results (estimates of intake and committed dose equivalent) are stored in separate data bases, and the bioassay measurements used to compute a given result can be identified. The REPORT module creates a file containing committed effective dose equivalent for each individual that can be combined with the individual's external exposure

  5. Portal dosimetry in wedged beams

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  6. Dosimetry for Electron Beam Applications

    Miller, Arne

    1983-01-01

    This report describes two aspects of electron bean dosimetry, on one hand developaent of thin fil« dosimeters and measurements of their properties, and on the other hand developaent of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film...

  7. Thermoluminescence dosimetry environmental monitoring system

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  8. Manual of food irradiation dosimetry

    1977-01-01

    Following items are discussed: Fundamentals of dosimetry; description of irradiators; dose distribution in the product and commissioning the process; plant operation and process control; detailed instructions on using various dose-meter systems; references; glossary of some basic terms and concepts

  9. Radiation dosimetry in nuclear medicine

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  10. Biological dosimetry of irradiation accidents

    Durand, V.; Chambrette, V.; Le Roy, A.; Paillole, N.; Sorokine, I.; Voisin, P.

    1994-01-01

    The biological dosimetry in radiation protection allows to evaluate the received dose by a potentially irradiated person from biological markers such chromosomal abnormalities. The technologies of Hybridization In Situ by Fluorescence (F.I.S.H) allow the detection of steady chromosomal aberrations of translocation type

  11. DOSCROS81. ECN Cross-Section Library for neutron dosimetry. Summary of contents and documentation

    Lemmel, H.D.

    1982-01-01

    This document summarizes the contents and documentation of the Cross Section Library DOSCROS81 (640 groups in an extended SAND-II format). The library is based on ENDF/B-5 dosimetry file, supplemented with some other evaluations. The total number of reaction cross section sets incorporated in this library is 70 (+3 cover cross section sets). The entire library can be obtained free of charge from the IAEA Nuclear Data Section. A revised version is called DOSCROS81A. (author)

  12. The personal dosimetry in Mexico

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  13. Impact of up-to-date evaluated nuclear data files on the Monte-Carlo analysis results of metallic fueled BFS critical assemblies

    Yoo, Jaewoon; Kim, Do-Heon; Kim, Sang-Ji; Kim, Yeong-Il

    2009-01-01

    Three metallic fueled BFS critical assemblies, BFS-73-1, BFS-75-1, and BFS-55-1 were analyzed by using the Monte-Carlo analysis code MCNP4C with five different evaluated data files, ENDF/B-VII.0, JEFF-3.1, JENDL-3.3, JENDL-AC and ENDF/B-VI.6. The impacts of microscopic cross sections in the up-to-date evaluated nuclear data files were clarified by the analyses. The update of Zr cross section leads to the calculated k-effective lower than that of ENDF/B-VI.6. The revision of U-238 inelastic scattering cross section makes large difference in the predicted k-effectives between the libraries, which depends on the amount of the contribution of the inelastic cross sections change and the compensation of other reaction types. The results of the spectral indices and reaction rate ratios shows the improvement of the up-to-date evaluated nuclear data files for the U-238, Np-237, Pu-240 fission reactions, however, there are still need of further improvement for other minor actinide cross sections. The heterogeneity effects involved on the k-effective and relative fission rate distribution were evaluated in this study, which can be used as the correction factor for constructing the homogeneous benchmark configuration while keeping the consistency with the actual critical experiment. (author)

  14. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  15. Dosimetry Control: Technic and methods. Proceedings of the international workshop 'Actual problems of dosimetry'

    Lyutsko, A.M.; Nesterenko, V.B.; Chudakov, V.A.; Konoplya, E.F.; Milyutin, A.A.

    1997-10-01

    There is a number of unsolved problems of both dosimetric and radiometric control, questions of the biological dosimetry, reconstruction of dozes of irradiation of the population at radiation incidents, which require coordination of efforts of scientists in various areas of a science. The submitted materials are grouped on five units: dosimetry engineering, biological dosimetry and markers of radiation impact, dosimetry of a medical irradiation, normative and measurement assurance of the dosimetric control, monitoring and reconstruction of dozes at radiation incidents

  16. The Latin American Biological Dosimetry Network (LBDNet)

    Garcia, O.; Lamadrid, A.I.; Gonzalez, J.E.; Romero, I.; Mandina, T.; Di Giorgio, M.; Radl, A.; Taja, M.R.; Sapienza, C.E.; Deminge, M.M.; Fernandez Rearte, J.; Stuck Oliveira, M.; Valdivia, P.; Guerrero-Carbajal, C.; Arceo Maldonado, C.; Cortina Ramirez, G.E.; Espinoza, M.; Martinez-Lopez, W.; Di Tomasso, M.

    2016-01-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. (authors)

  17. The Latin American Biological Dosimetry Network (LBDNet).

    García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M

    2016-09-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. A microcomputer controlled thermoluminescence dosimetry system

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  19. Thermoluminescent dosimetry in veterinary diagnostic radiology

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  20. Accidental and retrospective dosimetry using TL method

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  1. Neutron metrology file NMF-90. An integrated database for performing neutron spectrum adjustment calculations

    Kocherov, N.P.

    1996-01-01

    The Neutron Metrology File NMF-90 is an integrated database for performing neutron spectrum adjustment (unfolding) calculations. It contains 4 different adjustment codes, the dosimetry reaction cross-section library IRDF-90/NMF-G with covariances files, 6 input data sets for reactor benchmark neutron fields and a number of utility codes for processing and plotting the input and output data. The package consists of 9 PC HD diskettes and manuals for the codes. It is distributed by the Nuclear Data Section of the IAEA on request free of charge. About 10 MB of diskspace is needed to install and run a typical reactor neutron dosimetry unfolding problem. (author). 8 refs

  2. ACONC Files

    U.S. Environmental Protection Agency — ACONC files containing simulated ozone and PM2.5 fields that were used to create the model difference plots shown in the journal article. This dataset is associated...

  3. XML Files

    ... this page: https://medlineplus.gov/xml.html MedlinePlus XML Files To use the sharing features on this page, please enable JavaScript. MedlinePlus produces XML data sets that you are welcome to download ...

  4. 831 Files

    Social Security Administration — SSA-831 file is a collection of initial and reconsideration adjudicative level DDS disability determinations. (A few hearing level cases are also present, but the...

  5. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  6. The dosimetry programme of the IAEA

    1987-01-01

    Describes the activities of the IAEA's Dosimetry Laboratory which provides calibration and comparison services for secondary standard dosimetry laboratories (SSDLs) of Member States. In addition, a joint IAEA/WHO postal dosimetry service has been established for radiotherapy centers. The International Measurement System and the calibration ''chain'' from measurement standard instruments of the International Bureau of Weights and Measurements (BIPM) through the primary and secondary standards to the dosimeters of the users are presented as well

  7. Benchmark calculations for critical experiments at FKBN-M facility with uranium-plutonium-polyethylene systems using JENDL-3.2 and MVP Monte-Carlo code

    Obara, Toru; Morozov, A.G.; Kevrolev, V.V.; Kuznetsov, V.V.; Treschalin, S.A.; Lukin, A.V.; Terekhin, V.A.; Sokolov, Yu.A.; Kravchenko, V.G.

    2000-01-01

    Benchmark calculations were performed for critical experiments at FKBN-M facility in RFNC-VNIITF, Russia using JENDL-3.2 nuclear data library and continuous energy Monte-Carlo code MVP. The fissile materials were high-enriched uranium and plutonium. Polyethylene was used as moderator. The neutron spectrum was changed by changing the geometry. Calculation results by MVP showed some errors. Discussion was made by reaction rates and η values obtained by MVP. It showed the possibility that cross sections of U-235 had different trend of error in fast and thermal energy region respectively. It also showed the possibility of some error of cross section of Pu-239 in high energy region. (author)

  8. Some aspects on neutron dosimetry

    Henaish, B.A.; Youssef, S.K.

    1988-01-01

    The American National Council on Radiation Protection and measurements (1) has recently issued a statement regarding dose limitation system for neutrons. The changes proposed in that statement presented substantial problems regarding the personnel exposure to neutrons and had pointed out the need to reassess an adequate current neutron dosimetry practice. Generally, the same types of dosimeters i.e. Nuclear Track (NTA films) and TLD-Albedo, have been used at major nuclear facilities over the past 15 years. here recently, other dosimetry methods such as track etch with polycarbonates such as CR-39 have been developed. However these should be recognized as local systems aiming to the development of better and more applicable dosimeters. 4 tab

  9. Radiation protection dosimetry and calibrations

    Verhavere, Ph.

    2007-01-01

    At the SCK-CEN different specialised services are delivered for a whole range of external and internal customers in the radiation protection area. For the expertise group of radiation protection dosimetry and calibrations, these services are organized in four different laboratories: dosimetry, anthropogammametry, nuclear calibrations and non-nuclear calibrations. The services are given by a dedicated technical staff who has experience in the handling of routine and specialised cases. The scientific research that is performed by the expertise group makes sure that state-of-the-art techniques are being used, and that constant improvements and developments are implemented. Quality Assurance is an important aspect for the different services, and accreditation according national and international standards is achieved for all laboratories

  10. Dosimetry in radiotherapy. V.1

    1988-01-01

    A series of symposia on dosimetry in medicine and biology have been held by the IAEA in co-operation with WHO. The present symposium was the first one focusing on ''Dosimetry in Radiotherapy''. The papers presented reflected the different steps in the calibration chain such as the calibration standards established by the National Standards Laboratories and the conversion of the reading of calibrated instruments to the desired quantity, i.e. absorbed dose to water at a reference point in the user's beam at the radiotherapy clinic. The programme further examined the procedures necessary for optimization of the treatment of the patient, such as treatment planning methods, dose distribution studies, new techniques of dose measurement, improvements in the physical dose distributions/conformation therapy and special problems involved in total body treatments. Results of quality assurance in radiotherapy were presented from local hospitals as well as from national and international studies. Refs, figs and tabs

  11. Gel dosimetry for conformal radiotherapy

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  12. Relative dosimetry by Ebt-3

    De Leon A, M. A.; Rivera M, T.; Hernandez O, J. O.

    2015-10-01

    In the present work relative dosimetry in two linear accelerator for radiation therapy was studied. Both Varian Oncology systems named Varian Clinac 2100-Cd and MLC Varian Clinac i X were used. Gaf Chromic Ebt-3 film was used. Measurements have been performed in a water equivalent phantom, using 6 MV and 18 MV photon beams on both Linacs. Both calibration and Electron irradiations were carried out with the ionization chamber placed at the isocenter, below a stack of solid water slabs, at the depth of dose maximum (D max), with a Source-to-Surface Distance (SSD) of 100 cm and a field size of 10 cm x 10 cm. Calibration and dosimetric measurements photons were carried out under IAEA-TRS 398 protocol. Results of relative dosimetry in the present work are discussed. (Author)

  13. NOTE FROM THE DOSIMETRY SERVICE

    2002-01-01

    During March, the Dosimetry Service will be opened from 8h30 to 12h in the morning and closed every afternoon.   We have established that many people, who are provided regularly with a personal dosimeter (film badge), have changed their activity and do not need it anymore, because they do not, or only exceptionally, enter controlled areas. If you are one of these persons, please contact the Personal Dosimeter Service (tel: 72155). There is a simplified procedure for obtaining a dosimeter if you have an immediate need for short-term visits in controlled areas. A reduction of the number of persons on the regular distribution list of dosimeters would decrease our and the distributors workload. It would also contribute to significant savings in the dosimetry, and thus CERN, budget. We thank you in advance for your understanding and for your collaboration.

  14. Tissue equivalence in neutron dosimetry

    Nutton, D.H.; Harris, S.J.

    1980-01-01

    A brief review is presented of the essential features of neutron tissue equivalence for radiotherapy and gives the results of a computation of relative absorbed dose for 14 MeV neutrons, using various tissue models. It is concluded that for the Bragg-Gray equation for ionometric dosimetry it is not sufficient to define the value of W to high accuracy and that it is essential that, for dosimetric measurements to be applicable to real body tissue to an accuracy of better than several per cent, a correction to the total absorbed dose must be made according to the test and tissue atomic composition, although variations in patient anatomy and other radiotherapy parameters will often limit the benefits of such detailed dosimetry. (U.K.)

  15. Advantages and disadvantages of luminescence dosimetry

    Olko, Pawel, E-mail: Pawel.Olko@ifj.edu.p [Institute of Nuclear Physics Polish Academy of Science (IFJ PAN), Krakow (Poland)

    2010-03-15

    Owing to their excellent dosimetric properties, luminescence detectors of ionizing radiation are now extensively applied in individual dosimetry services. The most frequently used personal dosemeters are based on Optically Stimulated Luminescence (OSL), radiophotoluminescence (RPL) or thermoluminescence (TL). Luminescence detectors have also found several applications in clinical dosimetry, especially around new radiation modalities in radiotherapy, such as Intensity Modulated Radiotherapy (IMRT) or ion beam radiotherapy. Requirements of luminescence detectors applied in individual and clinical dosimetry and some recent developments in luminescence of detectors and techniques leading to significant improvements of the functionality and accuracy of dosimetry systems are reviewed and discussed.

  16. Dosimetry for electron beam sterilization

    Miller, A.

    2007-01-01

    According to ISO 11137-1 (sect 4.3.4) dosimetry used in the development, validation and routine control of the sterilization process shall have measurement traceability to national or international standards and shall have a known level of uncertainty. It can only be obtained through calibration of the dosimeters. In presented lecture different types of dosimeter systems for electron beams (calorimeters, radiochromic film dosimeters, alanine / EPR) and their calibration are described

  17. Dosimetry of β extensive sources

    Rojas C, E.L.; Lallena R, A.M.

    2002-01-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of β extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  18. EPR dosimetry - present and future

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as co-ordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as biomarkers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (ASTM), and the International Organisation of Standards (ISO) as well as those of the International Commission on Radiation Units and Measurements (ICRU) considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (author)

  19. EPR Dosimetry - Present and Future

    Regulla, D.F. [GSF - National Research Centre for Environment and Health, Institute of Radiation Protection, 85764 Neuherberg (Germany)

    1999-07-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  20. Fourth international radiopharmaceutical dosimetry symposium

    Schlafke-Stelson, A.T.; Watson, E.E.

    1986-04-01

    The focus of the Fourth International Radiopharmaceutical Dosimetry Symposium was to explore the impact of current developments in nuclear medicine on absorbed dose calculations. This book contains the proceedings of the meeting including the edited discussion that followed the presentations. Topics that were addressed included the dosimetry associated with radiolabeled monoclonal antibodies and blood elements, ultrashort-lived radionuclides, and positron emitters. Some specific areas of discussion were variations in absorbed dose as a result of alterations in the kinetics, the influence of radioactive contaminants on dose, dose in children and in the fetus, available instrumentation and techniques for collecting the kinetic data needed for dose calculation, dosimetry requirements for the review and approval of new radiopharmaceuticals, and a comparison of the effect on the thyroid of internal versus external irradiation. New models for the urinary blader, skeleton including the active marrow, and the blood were presented. Several papers dealt with the validity of traditional ''average-organ'' dose estimates to express the dose from particulate radiation that has a short range in tissue. These problems are particularly important in the use of monoclonal antibodies and agents used to measure intracellular functions. These proceedings have been published to provide a resource volume for anyone interested in the calculation of absorbed radiation dose

  1. EPR Dosimetry - Present and Future

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  2. I-124 Imaging and Dosimetry

    Russ Kuker

    2017-02-01

    Full Text Available Although radioactive iodine imaging and therapy are one of the earliest applications of theranostics, there still remain a number of unresolved clinical questions as to the optimization of diagnostic techniques and dosimetry protocols. I-124 as a positron emission tomography (PET radiotracer has the potential to improve the current clinical practice in the diagnosis and treatment of differentiated thyroid cancer. The higher sensitivity and spatial resolution of PET/computed tomography (CT compared to standard gamma scintigraphy can aid in the detection of recurrent or metastatic disease and provide more accurate measurements of metabolic tumor volumes. However the complex decay schema of I-124 poses challenges to quantitative PET imaging. More prospective studies are needed to define optimal dosimetry protocols and to improve patient-specific treatment planning strategies, taking into account not only the absorbed dose to tumors but also methods to avoid toxicity to normal organs. A historical perspective of I-124 imaging and dosimetry as well as future concepts are discussed.

  3. Individual monitoring dosimetry in Europe

    Menzel, H.G.

    1991-01-01

    This report discusses the various types of individual monitoring systems presently in use within the European community and neutron dosimetry research being coordinated by the EURADOS working group. Research is currently being conducted on nuclear track dosimeters, primarily with CR-39 (TM), and TLD-albedo dosimeters. Studies are being conducted on the energy and angular response of each type of dosimeter. Because the response of dosimeters depends on the energy of the neutrons, it is necessary to have spectral information to accurately assess the dose. Neutron energy spectrum measurements are being performed in typical work place environments. Work is also progressing on development of calibration sources which will be representative of the neutron energy spectrum found in typical neutron exposure situations. This work utilizes 14 MeV neutrons incident on a uranium block with various other filters. Research is also continuing on neutron dosimetry using tissue equivalent proportional counters and microdosimetric techniques. The results of intercomparisons between several different instruments are discussed. In addition to personnel dosimetry, these systems are being used to record the dose to passengers and flight crews aboard commercial aircraft

  4. Developments in physical dosimetry and radiation protection; Entwicklungen in der physikalischen Dosimetrie im Strahlenschutz

    Fiebich, Martin [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-07-01

    In the frame of physical dosimetry new dose units have been defined: the depth personal dose (equivalent dose in 10 mm depth) and the surface personal dose (equivalent dose in 0.07 mm depth). Physical dosimetry is applied for the determination of occupational radiation exposure, the radiation protected area control, the estimation of radiation exposure of patients during radiotherapy, for quality assurance and in research projects and optimization challenges. Developments have appeared with respect to punctual measuring chambers, eye lens dosimetry, OSL (optically stimulated luminescence) dosimetry, real-time dosimetry and Monte Carlo methods. New detection limits of about 1 micro Gy were reached.

  5. Retrospective dosimetry of Chernobyl liquidators

    Chumak, V.V.; Bakhanova, E.V.; Sholom, S.V.; Pasalskaya, L.F.; Bouville, A.; Krjuchkov, V.P.

    2000-01-01

    The numerous cohort of Chernobyl liquidators is a very attractive subject for epidemiological follow up due to high levels of exposure, age-gender distribution and availability of patients for medical examination. However, dosimetric information related to this population is incomplete, in many cases the quality of available dose records is doubtful and uncertainties of all dose values are not determined. Naive attempts to evaluate average doses on the basis of such factors as 'distance from the reactor' obviously fail due to large variation of tasks and workplace contamination. Therefore, prior to any sensible consideration of liquidators as a subject of epidemiological study, their doses should be evaluated (reevaluated) using the methods of retrospective dosimetry. Retrospective dosimetry in general got significant development over the last decade. However, most of the retrospective dosimetry techniques are time consuming, expensive and possess sensitivity threshold. Therefore, application of retrospective dosimetry for the needs of epidemiological follow up studies requires development of certain strategy. This strategy depends, of coarse, on the epidemiological design of the study, availability of resources and dosimetric information related to the time of clean up. One of the strategies of application of retrospective dosimetry may be demonstrated on the example of a cohort study with occasional nested case control consideration. In this case, the tools are needed for validation of existing dose records (of not always known quality), screening of the study cohort with express dosimetric method called to determine possible dose ranges, and 'state-of-the-art' assessment of individual doses for selected subjects (cases and controls). Verification of dose records involves analysis of the statistical regularities of dose distributions and detection of possible extraneous admixtures (presumably falsified dose records). This work is performed on impersonified data

  6. Mister Voxel: 3D internal dosimetry software for nuclear medicine

    McKay, E.

    1998-01-01

    Full text: Calculation of individual internal dosimetry in nuclear medicine is a complex, multi-stage process. Most often, calculations are biased on the MIRD methodology, which assumes uniform distribution of cumulated activity inside a set of mathematically described internal organs. The MIRD 'reference man' geometry is highly simplified and the dosimetry estimates generated by this method were originally only intended to predict the average dose expected in an exposed population. We have developed a software package for the Macintosh computer ('Mister Voxel') that uses a fast Fourier transform to calculate the 3D distribution of absorbed dose by convolving a 3D dose kernel with a 3D distribution of cumulated activity. This makes it possible to generate dose volume histograms and isodose contours for organs or tumours treated with radiopharmaceuticals, a task not possible using the MIRD technique. In addition to providing 3D convolution, Mister Voxel performs basic image processing functions (image math, filters, cut and paste) and provides a collection of painting tools and simple morphological operators to facilitate the delineation of regions of interest (ROIs) along anatomical boundaries. The package also includes an image registration module with tools for automated or manual registration of 3D data sets. The structure of the package allows ROIs drawn on CT or MRI data to be easily transferred to registered SPECT data. Dose kernels are implemented by plug-in code modules, allowing the user to extend the system's capabilities if required. File import and export capabilities are also extensible

  7. Present status and history of nuclear data development for transmutation technology

    Hasegawa, A

    2002-01-01

    A history of development of nuclear data from JENDL (Japanese Evaluated Nuclear Data Library)-1 to JENDL-3.3 and JENDL-HF (High energy File) and JENDL- Actinide File are stated. 5 nuclear data such as JENDL-1, JENDL-2, JENDL-3.1, JENDL-3.2 and JENDL-3.3 have been developed by JAERI. JENDL-1 for fast reactor (1977) has 66+6 nuclide and 15 MeV the largest energy. JENDL-2 for fast and light water reactor (1982) has 173+8 nuclide and 20 MeV. All-purpose nuclear data: JENDL-3.1 (1990) with 305+19 nuclide and 59 2nd gamma-ray data, JENDL-3.2 (1994) with 318+22 nuclide and 66 2nd gamma-ray data and JENDL-3.3 (2002) with 335+2 nuclide, 114 2nd gamma-ray data, 60 angular dependence neutron data and 20 MeV have been developed. JENDL-3.3 was opened at JAERI home page in May 2002. JENDL High Energy library consists of JENDL-HF, JENDL-Photonuclear Data File and JENDL-PKA/KERMA File. JENDL-HF includes nuclear reaction data of neutron and proton incidence, for example, total cross section, elastic scattering cross section a...

  8. Thermoluminescent measurement in space radiation dosimetry

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  9. Sizewell B Power Station control dosimetry system

    Renn, G.

    1995-01-01

    Sizewell B Power Station is the first Pressurized Water Reactor (PWR) built in the UK for commercial electricity production. An effective control dosimetry system is a crucial tool, in allowing the station to assess its radiological performance against targets. This paper gives an overview of the control dosimetry system at Sizewell B and describes early operating experience with the system. (UK)

  10. Mixed field dosimetry with paired ionization chambers

    Coppola, M.; Porro, F.

    1977-01-01

    This report describes the results of neutron and gamma mixed-field dosimetry obtained by the Ispra Group in the framework of the European Neutron Dosimetry intercomparison Project (ENDIP). The experimental method and the formulation employed for the derivation of Kerma results are also present

  11. Dosimetry system of the RB reactor

    Lolic, B.; Vukadin, D.

    1962-01-01

    Although RB reactor is operated at very low power levels, safety and dosimetry systems have high importance. This paper shows detailed dosimetry system with fundamental typical components. Estimated radiation doses dependent on reactor power are given at some characteristic points in the rooms nearby reactor

  12. Uncertainty analysis of dosimetry spectrum unfolding

    Perey, F.G.

    1977-01-01

    The propagation of uncertainties in the input data is analyzed for the usual dosimetry unfolding solution. A new formulation of the dosimetry unfolding problem is proposed in which the most likely value of the spectrum is obtained. The relationship of this solution to the usual one is discussed

  13. Research and innovation in radiation dosimetry

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  14. Report on external occupational dosimetry in Canada

    1995-12-01

    In light of the new recommendations of the ICRP in Report 60 on dose quantities and dose limits, this working group was set up to examine the implications for external dosimetry in Canada. The operational quantities proposed by the ICRU are discussed in detail with regard to their applicability in Canada. The current occupational dosimetry services available in Canada are described as well as the several performance intercomparisons that have been carried out within the country as well as internationally. Recommendations are given with respect to standards for dosimetry, including accuracy and precision. More practical advice is given on the choice of dosimeter to use for external dosimetry, frequency of monitoring, and who should be monitored. Specific advice is given on the monitoring of pregnant workers and problem of non-uniform irradiation. Accident and emergency dosimetry are dealt with briefly. Suggestions are given regarding record keeping both for employers and for the national dose registry. 48 refs., 6 tabs., 1 fig

  15. Status of the ENDF/B special applications files

    Stewart, L.

    1977-01-01

    The newly formed SAFE Subcommittee of the Cross Section Evaluation Working Group is charged with the responsibility for providing, reviewing, and testing several ENDF/B special purpose evaluated files. This responsibility currently encompasses dosimetry, activation, hydrogen and helium production, and radioactive decay data required by a variety of users. New formats have been approved by CSEWG for the inclusion of the activation and hydrogen and helium production cross-section libraries. The decay data will be in the same format as that already employed by the Fission Product and Actinide Subcommittee of CSEWG. While an extensive dosimetry file was available on the ENDF/B-IV library for fast reactor applications, other data are needed to extend the range of applications, especially to higher incident neutron energies. This Subcommittee has long-range plans to provide evaluated neutron interaction data that can be recommended for use in many specialized applications. 1 figure, 3 tables

  16. Next decade in external dosimetry

    Griffith, R.V.

    1988-01-01

    In recent years, a number of external dosimetry problems have been solved. However, changes in standards and legal concepts relating to the application of dosimetry results will require further enhancements in measurement techniques and philosophy in the next 10 y. The introduction of effective dose equivalent and the legal use of probability of causation will require that much greater attention be given to determination of weighted organ dose from external exposure. An imminent change--an increase in the fast neutron quality factor--will require a new round of technology development in a field that has just received a decade of close scrutiny. For the future, we must take advantage of developments in microelectronics. The use of random access memory (RAM) and metal-on-silicon (MOS) devices as detector elements, particularly for neutron dosimetry, has exciting possibilities that are just beginning to be explored. Advances in microcircuitry are leading, and will continue to lead, in the development of a new generation of small, rugged and smart radiation survey instruments that will make the most of detector data. It has become possible with very compact instruments to obtain energy spectra, linear-energy-transfer (LET) spectra, and quality factors in addition to the usual integrated dosimetric quantities: exposure, absorbed dose, and dose equivalent. These instruments will be reliable and easy to use. The user will be able to select the level of sophistication that is required for any specific application. Moreover, since the processing algorithms can be changed, changes in conversion factors can be accommodated with relative ease. During the next decade, the use of computers will continue to grow in value to the health physicist

  17. Patient dosimetry in diagnostic radiology

    Shrimpton, P.C.

    2000-01-01

    Full text: X-ray examinations remain an essential and widely used diagnostic tool in medicine and hence the most significant source of exposure to man-made radiation for populations. Patterns of practice in diagnostic radiology continue to evolve, with overall growth in the numbers of procedures worldwide and, particularly in developed countries, increasing importance for complex procedures such as computed tomography (CT) and interventional techniques. In order to maximise the benefits from x-rays relative to the associated radiation risks, there is a need to ensure the prior justification of all examinations and the optimisation of patient protection such that doses are as low as reasonably practicable to meet specific clinical requirements. Accordingly, patient dosimetry is a fundamental requirement in diagnostic radiology. Detailed measurements for the assessment of risks or comparison of different types of procedure require the estimation of organ and effective doses. Such comprehensive dosimetry necessarily involves the simulation of clinical practice using anthropomorphic phantoms, with either measurements in a physical phantom or calculations utilising a mathematical phantom. Simpler measurements for the routine monitoring of dose in x-ray departments can be based on practical quantities such as entrance surface dose, dose-area product and, for CT, weighted CT dose index and dose-length product. Widescale surveys reveal significant variations between departments in the typical doses for a given type of procedure and potential scope for dose reductions. In order to promote improvements in practice, the results of periodic dose surveys in departments should be compared with appropriate standards, such as diagnostic reference levels for adult and paediatric patients, that are set nationally or locally for the purposes of promoting critical review of the equipment and techniques in use. Patient dosimetry should form an essential element of routine quality

  18. Radiation dosimetry and standards at the austrian dosimetry laboratory

    Leitner, A.

    1984-10-01

    The Austrian Dosimetry Laboratory, established and operated in cooperation between the Austrian Research Center Seibersdorf and the Federal Office of Metrology and Surveying (Bundesamt and Eich- und Vermessungswesen) maintains the national primary standards for radiation dosimetry. Furthermore its tasks include routine calibration of dosemeters and dosimetric research. The irradiation facilities of the laboratory comprise three X-ray machines covering the voltage range from 5 kV to 420 kV constant potential, a 60 Co teletherapy unit, a circular exposure system for routine batch calibration of personnel dosemeters with four gamma ray sources ( 60 Co and 137 Cs) and a reference source system with six gamma ray sources ( 60 Co and 137 Cs). In addition a set of calibrated beta ray sources are provided ( 147 Pm, 204 Tl and 90 Sr). The dosimetric equipment consists of three free-air parallelplate ionization chambers serving as primary standards of exposure for the X-ray energy region, graphite cavity chambers with measured volume as primary standards for the gamma radiation of 137 Cs and 60 Co as well as different secondary standard ionization chambers covering the dose rate range from the natural background level up to the level of modern therapy accelerators. In addition for high energy photon and electron radiation a graphite calorimeter is provided as primary standard of absorbed dose. The principle experimental set-ups for the practical use of the standards are presented and the procedures for the calibration of the different types of dosemeters are described. (Author)

  19. The RERF dosimetry measurements database

    Cullings, Harry M.; Fujita, Shoichiro; Preston, Dale L.; Grant, Eric J.; Shizuma, Kiyoshi; Hoshi, Masaharu; Maruyama, Takashi; Lowder, Wayne M.

    2005-01-01

    The Radiation Effects Research Foundation maintains a database containing detailed information on every known measurement of environmental materials in the cities of Hiroshima and Nagasaki for gamma-ray thermoluminescence or neutron activation produced by incident radiation from the atomic bomb detonations. The intent was to create a single information resource that would consistently document, as completely as possible in each case, a standard array of data for every known measurement. This database provides a uniquely comprehensive and carefully designed reference for the dosimetry reassessment. (J.P.N.)

  20. The Future of Medical Dosimetry

    Adams, Robert D., E-mail: robert_adams@med.unc.edu

    2015-07-01

    The world of health care delivery is becoming increasingly complex. The purpose of this manuscript is to analyze current metrics and analytically predict future practices and principles of medical dosimetry. The results indicate five potential areas precipitating change factors: a) evolutionary and revolutionary thinking processes, b) social factors, c) economic factors, d) political factors, and e) technological factors. Outcomes indicate that significant changes will occur in the job structure and content of being a practicing medical dosimetrist. Discussion indicates potential variables that can occur within each process and change factor and how the predicted outcomes can deviate from normative values. Finally, based on predicted outcomes, future opportunities for medical dosimetrists are given.

  1. Review on individual neutron dosimetry

    Portal, M.

    1983-01-01

    Up to now, nuclear energy workers in relation to neutron radiations were few. Fast development of nuclear energy lead us to study, for future, individual dosimetry techniques which are autonomous, more accurate and cheaper. The future dosemeter will be a couple: fast neutron dosemeter and slow neutron dosemeter. The different current studies concerning this ''composite'' dosemeter are described. In 1984-1985, operation of a ''non-homogeneous, composite'' dosemeter is foreseen; later on, an ''homogeneous composite'' dosemeter that is to say a dosemeter which needs same basis techniques [fr

  2. NMR mechanisms in gel dosimetry

    Schreiner, L J

    2009-01-01

    Nuclear magnetic resonance was critical to the development of gel dosimetry, as it established the potential for three dimensional dosimetry with chemical dosimeter systems through magnetic resonance imaging [1]. In the last two decades MRI has served as the gold standard for imaging, while NMR relaxometry has played an important role in the development and understanding of the behaviour of new gel dosimetry systems. Therefore, an appreciation of the relaxation mechanisms determining the NMR behaviour of irradiated gel dosimeters is important for a full comprehension of a considerable component of the literature on gel dosimetry. A number of excellent papers have presented this important theory, this brief review will highlight some of the salient points made previously [1-5]. The spin relaxation of gel dosimeters (which determines the dose dependence in most conventional MR imaging) is determined principally by the protons on water molecules in the system. These water protons exist in different environments, or groups (see Figure 1): on bulk water, on water hydrating the chemical species that are being modified under irradiation, and on water hydrating the gel matrix used to spatially stabilize the dosimeter (e.g., gelatin, agarose, etc). The spin relaxation depends on the inherent relaxation rate of each spin group, that is, on the relaxation rate which would be observed for the specific group if it were isolated. Also, the different water environments are not isolated from each other, and the observed relaxation rate also depends on the rate of exchange of magnetization between the groups, and on the fraction of protons in each group. In fact, the water exchanges quickly between the environments, so that relaxation is in what is usually termed the fast exchange regime. In the limit of fast exchange, the relaxation of the water protons is well characterized by a single exponential and hence by a single apparent relaxation rate. In irradiated gel dosimeters this

  3. Recent research into thermoluminescent dosimetry

    Nakajima, T [National Inst. of Radiological Sciences, Chiba (Japan)

    1979-04-01

    The trend of basic research in thermoluminescent dosimetry (TLD), the results, and developing fields in which it can be applied are reported. This trend is outlined from the viewpoint fields of application, a new trend in TLD readers, the conditions of development of new photogenic substances, and research in the radiation characteristics of photogenic substances (radiosensitivity to particle rays and ultraviolet rays, dose rate dependence, temperature dependence at irradiation, and ..gamma.. ray energy dependence). Utilization of TLD in the medical field for measurement of environmental radiation and as a monitor for workers exposed to radiation is discussed. An international comparison of dose was necessary in order to prove its universal validity.

  4. Gamma dosimetry of high doses

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  5. The internal dosimetry code PLEIADES.

    Fell, T P; Phipps, A W; Smith, T J

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts-the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included.

  6. The internal dosimetry code PLEIADES

    Fell, T. P.; Phipps, A. W.; Smith, T. J.

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts - the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included. (authors)

  7. Dosimetry for electron beam application

    Miller, A.

    1983-12-01

    This report describes two aspects of electron beam dosimetry, on one hand development of film dosimeters and measurements of their properties, and on the other hand development of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film dosimeters have been developed in this department, and the properties of these and commercially available dosimeters have been measured and found to be comparable. Calorimeters which are in use for routine measurements, are being investigated with reference to their application as standardizing instruments, and new calorimeters are being developed. (author)

  8. New remarks on KERMA factors and DPA cross section data in ACE files

    Konno, Chikara; Sato, Satoshi; Ohta, Masayuki; Kwon, Saerom; Ochiai, Kentaro

    2016-01-01

    KERMA factors and DPA cross section data are essential for nuclear heating and material damage estimation in fusion reactor designs. Recently we compared KERMA factors and DPA cross section data in the latest official ACE files of JENDL-4.0, ENDF/B-VII.1, JEFF-3.2 and FENDL-3.0 and it was found out that the KERMA factors and DPA cross section data of a lot of nuclei did not always agree among the nuclear data libraries. We investigated the nuclear data libraries and the nuclear data processing code NJOY and specified new reasons for the discrepancies; (1) incorrect nuclear data and NJOY bugs, (2) huge helium production cross section data, (3) gamma production data format in the nuclear data, (4) no detailed secondary particle data (energy–angular distribution data). These problems should be resolved based on this study.

  9. New remarks on KERMA factors and DPA cross section data in ACE files

    Konno, Chikara, E-mail: konno.chikara@jaea.go.jp; Sato, Satoshi; Ohta, Masayuki; Kwon, Saerom; Ochiai, Kentaro

    2016-11-01

    KERMA factors and DPA cross section data are essential for nuclear heating and material damage estimation in fusion reactor designs. Recently we compared KERMA factors and DPA cross section data in the latest official ACE files of JENDL-4.0, ENDF/B-VII.1, JEFF-3.2 and FENDL-3.0 and it was found out that the KERMA factors and DPA cross section data of a lot of nuclei did not always agree among the nuclear data libraries. We investigated the nuclear data libraries and the nuclear data processing code NJOY and specified new reasons for the discrepancies; (1) incorrect nuclear data and NJOY bugs, (2) huge helium production cross section data, (3) gamma production data format in the nuclear data, (4) no detailed secondary particle data (energy–angular distribution data). These problems should be resolved based on this study.

  10. Instrumentation for Dosimetry. Chapter 21

    Hourdakis, J. C. [Greek Atomic Energy Commission, Athens (Greece); Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    Measurements of absorbed dose (or air kerma) are required in varying situations in diagnostic radiology. The radiation fields vary from plain, slit and even point projection geometry, and may be stationary or moving, including rotational. Owing to the use of low photon energies for these fields, it is important that dosimeters have a satisfactory energy response. In general, the requirements for dosimeter accuracy are less stringent than those in radiation therapy; however, the dose and dose rate measurements cover a large range. Patient dosimetry (see Chapter 22) is a primary responsibility of the medical physicist specializing in diagnostic radiology and is required by legislation in many countries. Dose data are also required in the optimization of examinations for image quality and dose. Radiation measurement is also critical for occupational and public exposure control (see Chapter 24). Dose measurements are essential in acceptance testing and quality control (see Chapter 19). Several types of dosimeter can be used, provided that they have a suitable energy response, but typically, ionization chambers of a few cubic centimetres in volume, or solid state detectors specifically designed for such measurements, are used. If dosimeters are used to make measurements during an examination, they must not interfere with the examination. These devices are also used for determination of the half value layer (HVL). Special types of ionization chamber are employed for computed tomography (CT), mammography and interventional radiology dosimetry.

  11. Fast neutron dosimetry: Progress summary

    DeLuca, P.M. Jr.

    1988-01-01

    The purpose was to investigate the radiological physics and biology of very low energy photons derived from a 1-GeV electron synchrotron storage ring. An extensive beam line and irradiation apparatus was designed, developed, and constructed. Dosimetry measurements required invention and testing of a miniature absolute calorimeter and a cell irradiation fixture suitable for scanning exposures under computer control. Measurements of the kerma factors of oxygen, aluminum and silicon for 14-20 MeV neutrons. Custom designed miniature proportional counters of cylindrical symmetry were employed in these determinations. The oxygen kerma factor was found significantly lower than values calculated from microscopic cross sections. We also tested Mg and Fe walled conventional spherical counters. The direct neutron-counting gas interaction is significant enough for these counters that a correction is needed. We also investigated the application of Nuclear Magnetic Resonance spectroscopy to radiation dosimetry. Our purpose was to take advantage of recent development of very high-field magnets, complex RF-pulse techniques for solvent suppression, and improved spectral analysis techniques

  12. Non-conventional personal dosimetry techniques

    Regulla, D.F.

    1984-01-01

    Established dosimetry has achieved a high standard in personnel monitoring. This applies particularly to photon dosimetry. Nevertheless, even in photon dosimetry, improvements and changes are being made. The reason may be technological progress, or the introduction of new tasks on the basis of the recommendations of international bodies (e.g. the new ICRU measurement unit) of national legislation. Since we are restricting ourselves here to technical trends the author would like to draw attention to various activities of current interest, e.g. the computation of receptor-related conversion coefficients from personal dose to organ or body doses, taking into account the conditions of exposure with respect to differential energy and angular distribution of the radiation field. Realistic data on exposure geometry are taken from work place analyses. Furthermore, the data banks of central personal dosimetry services are subject to statistical evaluation and radiation protection trend analysis. Technological progress and developments are considered from the point of view of personal dosimetry, partial body or extremity dosimetry and accidental dosimetry

  13. Neutron personnel dosimetry considerations for fusion reactors

    Barton, T.P.; Easterly, C.E.

    1979-07-01

    The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power

  14. Using NJOY to Create MCNP ACE Files and Visualize Nuclear Data

    Kahler, Albert Comstock [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-14

    We provide lecture materials that describe the input requirements to create various MCNP ACE files (Fast, Thermal, Dosimetry, Photo-nuclear and Photo-atomic) with the NJOY Nuclear Data Processing code system. Input instructions to visualize nuclear data with NJOY are also provided.

  15. Characterization of commercial MOSFETS electron dosimetry

    Carvajal, M. A.; Simancas, F.; Guirado, D.; Banqueri, J.; Vilches, M.; Lallena, A. M.; Palma, A. J.

    2011-01-01

    In recent years there have been commercial dosimetry devices based on transistors Metal-Oxide-Semiconductor (MOSFET) having a number of advantages over traditional systems for dosimetry in medical applications. These include the portability of the sensor element and a reading process quick and relatively simple dose, linearity, and so on. The use of electron beams is important in modern radiotherapy include its use in intra-operative radiotherapy (RIO). This paper presents an initial characterization of different business models MOSFET, not specific for radiation detection, to demonstrate their potential as sensors for electron beam dosimetry. (Author)

  16. Introduction to radiological physics and radiation dosimetry

    Attix, Frank Herbert

    2004-01-01

    A straightforward presentation of the broad concepts underlying radiological physics and radiation dosimetry for the graduate-level student. Covers photon and neutron attenuation, radiation and charged particle equilibrium, interactions of photons and charged particles with matter, radiotherapy dosimetry, as well as photographic, calorimetric, chemical, and thermoluminescence dosimetry. Includes many new derivations, such as Kramers X-ray spectrum, as well as topics that have not been thoroughly analyzed in other texts, such as broad-beam attenuation and geometrics, and the reciprocity theorem

  17. Accuracy Requirements in Medical Radiation Dosimetry

    Andreo, P.

    2011-01-01

    The need for adopting unambiguous terminology on 'accuracy in medical radiation dosimetry' which is consistent with international recommendations for metrology is emphasized. Uncertainties attainable, or the need for improving their estimates, are analysed for the fields of radiotherapy, diagnostic radiology and nuclear medicine dosimetry. This review centres on uncertainties related to the first step of the dosimetry chain in the three fields, which in all cases involves the use of a detector calibrated by a standards laboratory to determine absorbed dose, air kerma or activity under reference conditions in a clinical environment. (author)

  18. Dosimetry optimization at COGEMA-La Hague

    Kalimbadjian, J.

    2000-01-01

    At the present time, the la Hague site strives to apply international recommendations together with national regulations concerning radiation protection, and especially the respect of limitation and optimization principles. The application of these principles is based on the implementation of a passive dosimetry and an active dosimetry. The monthly passive dosimetry is monitored by means of a photographic dosimetry film, completed with lithium fluorine thermoluminescent film badges. This personal dosimetry common to X, β, γ and neutron radiations is carried out in close relationship between the Radiation Protection Department, the Occupational Medical Department and the staff running the Plant. The application or ALARA's principle as well as that of radiation protection optimization implies to implement a complementary active dosimetry enabling to gain in real time, the personal dosimetry of each intervening person, either they be COGEMA's workers or external companies'. This active dosimetry provides with following information: This preventive dosimetry is based on the knowledge of doses integration in real time and is fitted with alarm thresholds according to the total amount of doses and dose rates. Thresholds on the dose rate are also set relatively to the radiological environment. This knowledge of doses and dose rates allows a stricter management of the works, while analyzing them according to the nature of the work, to the location and to the skills of the intervening people. This dosimetry allows to analyze and optimize doses integration according to the works nature for the whole intervening staff. The la Hague Site has developed an active personal dosimetry system, common to every intervening person, COGEMA or external companies. The DOSICARD was thus elaborated, shaped as an electronic dosimeter fitted with an alarm and a smart card. The access to controlled areas is conditioned to information given by the DOSICARD concerning medical aptitudes and

  19. Radiographic film orientation in radiotherapy dosimetry

    Suchowerska, N.; Davison, A.; Drew, J.; Metcalfe, P.

    1996-01-01

    Since the discovery of x-rays, film has been used as a detection medium for radiation. More recently radiographic film has become established as a practical tool for the measurement of dose distribution in radiotherapy. The accuracy and reproducibility of film dosimetry depends on photon energy, processing conditions and film plane orientation. The relationship between photon energy, processing conditions and film dosimetry accuracy has been studied. The role of film plane orientation is still controversial. The current work aims to clarify the effects film plane orientation has on film dosimetry. Poster 205. (author)

  20. A graphical user interface for diagnostic radiology dosimetry using Monte Carlo (MCNP) simulation

    Collins, P.J.; Gorbatkov, D.; Schultz, F.W.

    2000-01-01

    Monte Carlo methods (for example, MCNP, EGGS4) are the 'gold standard' for both external and internal dosimetry in humans. These powerful simulation tools are, however, general-purpose codes and consequently do not provide a simple user interface for specific dosimetry tasks. We have developed a graphical user interface, for external radiation dosimetry (diagnostic radiology) using MCNP and an anthropomorphic mathematical phantom (Adam/Eva), which enables convenient modification and processing of the MCNP input and output files. The input form displays a colour coded, 3D representation of the phantom with a superimposed 'beam' for the required x-ray projection. The phantom can be rotated through 360 degrees and a transverse section at the level of the mid-point of the beam is also displayed. Text fields enable entry of input data (beam dimensions, source position, kVp, total filtration, focus-to-skin distance). A pull-down menu enables the user to select from 22 standard radiographic views. A standard projection can be modified, or new projection data entered if required. The input program modifies the MCNP input file and initiates processing. An output form displays the organ doses, normalised to unit skin entrance dose (with backscatter) (SED). The user can also enter the SED (calculated or measured) for a particular machine, to obtain the effective dose. To validate the program, the results for a PA Chest study (80 kVp, 2.5 mm Al total filtration) were compared with NRPB data (Jones and Wall, 1985). In conclusion, a convenient and reliable graphical user interface has been developed for MCNP, which enables dosimetry calculation for a full range of diagnostic radiological studies. (author)

  1. External dosimetry by Thermoluminescent Dosimetry Laboratory - IPEN/CNEN - Brazil

    Manzoli, Jose Eduardo; Carvalho, Ricardo Nunes

    2001-01-01

    The Thermoluminescence Dosimetry Laboratory, LDT - IPEN/CNEN - Brazil, executes around six thousand TLD readings monthly. It is responsible for the dose evaluation and registration and for all the manufacture process of preparation and sending the dosemeters which are used by IPEN itself, hospitals, industries, town halls, universities, etc. Although prepared to read many kinds of materials, actually the LDT reads only CaSO 4 :Dy detector chips. Chips, heating molds, plastic packaging and almost every material or instrument are made right here at IPEN. The readings are performed in a Bicron Harshaw TLD model 5500, but an old model 2000-AB is ready to be used if necessary. In this work it is presented some features of this important service realized to the IPEN workers and to the community. (author)

  2. Comparative studies of JENDL-3.3, JENDL-3.2, JEFF-3, JEF-2.2 and ENDF/B-6.8 data libraries on the Monte Carlo continuous energy modeling of the gas turbine-modular helium reactor operating with thorium fuels

    Talamo, Alberto; Gudowski, Waclaw

    2005-01-01

    One of the major benefits of the Gas Turbine-Modular Helium Reactor is the capability to operate with several different types of fuel; either Light Water Reactors waste, military plutonium or thorium represent valid candidates as possible types of fuel. In the present studies, we performed a comparison of various nuclear data libraries by the Monte Carlo Continuous Energy Burnup Code MCB applied to the Gas Turbine-Modular Helium Reactor operating on a thorium fuel. A thorium fuel offers valuable attractive advantages: low fuel cost, high reduction of actinides production and the possibility to enable the reactor to act as a breeder of fuel by the neutron capture of fertile 232 Th. We evaluated the possibility to mix thorium with small quantities, about 3% in atomic composition, of 239 Pu, 233 U and 235 U. The mass of thorium must be much larger than that one of plutonium or uranium because of the low capture cross section of thorium compared to the fission one of the fissile nuclides; at the same time, the quantity of the fissile isotopes must grant the criticality condition. These two simultaneous constraints force to load a huge mass of fuel in the reactor; consequently, we propose to allocate the fuel in TRISO particles with a large radius of the kernel. For each of the three different fuels we calculated the evolution of the fuel composition by the MCB code equipped with five different nuclear data libraries: JENDL-3.3, JENDL-3.2, JEFF-3, JEF-2.2 and ENDF/B. (author)

  3. Dosimetry techniques applied to thermoluminescent age estimation

    Erramli, H.

    1986-12-01

    The reliability and the ease of the field application of the measuring techniques of natural radioactivity dosimetry are studied. The natural radioactivity in minerals in composed of the internal dose deposited by alpha and beta radiations issued from the sample itself and the external dose deposited by gamma and cosmic radiations issued from the surroundings of the sample. Two technics for external dosimetry are examined in details. TL Dosimetry and field gamma dosimetry. Calibration and experimental conditions are presented. A new integrated dosimetric method for internal and external dose measure is proposed: the TL dosimeter is placed in the soil in exactly the same conditions as the sample ones, during a time long enough for the total dose evaluation [fr

  4. Beta calibration and dosimetry at IPEN

    Caldas, L.V.E.

    1983-01-01

    A commercial extrapolation chamber (PTW, Germany) was tested in different beta radiation fields and its properties investigated. Its usefullness for beta radiation calibration and dosimetry was demonstrated. (Author) [pt

  5. Report on high energy neutron dosimetry workshop

    Alvar, K.R.; Gavron, A.

    1993-01-01

    The workshop was called to assess the performance of neutron dosimetry per the responses from ten DOE accelerator facilities to an Office of Energy Research questionnaire regarding implementation of a personnel dosimetry requirement in DRAFT DOE 5480.ACC, ''Safety of Accelerator Facilities''. The goals of the workshop were to assess the state of dosimetry at high energy accelerators and if such dosimetry requires improvement, to reach consensus on how to proceed with such improvements. There were 22 attendees, from DOE Programs and contract facilities, DOE, Office of Energy Research (ER), Office of Environmental Safety and Health (EH), Office of Fusion Energy, and the DOE high energy accelerator facilities. A list of attendees and the meeting agenda are attached. Copies of the presentations are also attached

  6. VIII. national symposium on radiation dosimetry

    1990-07-01

    The publication contains abstracts of 107 contributions, dealing mainly with general problems of radiation dosimetry and with its practical applications, particularly in nuclear power industry and in medicine. (Z.M.)

  7. Implementation of an alanine dosimetry service

    Gago Arias, A.; Nunez Pelaez, N.; Peteiro Vilaseco, E.; Gomez Rodriguez, F.; Gonzalez Castano, D. M.

    2011-01-01

    This work facing the implementation of an alanine dosimetry service, linked to the installation of Co 6 0 Radio physics Laboratory (LP) and Paramagnetic Resonance Service of the University of Santiago de Compostela (USC).

  8. Cross sections required for FMIT dosimetry

    Gold, R.; McElroy, W.N.; Lippincott, E.P.; Mann, F.M.; Oberg, D.L.; Roberts, J.H.; Ruddy, F.H.

    1980-01-01

    The Fusion Materials Irradiation Test (FMIT) facility, currently under construction, is designed to produce a high flux of high energy neutrons for irradiation effects experiments on fusion reactor materials. Characterization of the flux-fluence-spectrum in this rapidly varying neutron field requires adaptation and extension of currently available dosimetry techniques. This characterization will be carried out by a combination of active, passive, and calculational dosimetry. The goal is to provide the experimenter with accurate neutron flux-fluence-spectra at all positions in the test cell. Plans have been completed for a number of experimental dosimetry stations and provision for these facilities has been incorporated into the FMIT design. Overall needs of the FMIT irradiation damage program delineate goal accuracies for dosimetry that, in turn, create new requirements for high energy neutron cross section data. Recommendations based on these needs have been derived for required cross section data and accuracies

  9. Internal dosimetry - its evolution and new trends

    Bertelli, Luiz

    1997-01-01

    This paper presents some discussions on the developments and trends of metabolic models and dosimetry and their associated parameters, which have been adopted by ICRP to evaluate intakes of radionuclides

  10. Need of Reactor Dosimetry Preservation

    Ilieva, Krassimira

    2011-01-01

    The nuclear safety requirements and philosophy have changed by the development of new nuclear systems and this imposes special research and development activity. Reactor dosimetry which is applied for determination of neutron field parameters and neutron flux responses in different regions of the reactor system plays an important role in determining of radiation exposure on reactor system elements as reactor vessel, internals, shielding; dose determination for material damage study; for conditioning of irradiation; dose determination for medicine and industry application; induced activity determination for decommissioning purposes. The management of nuclear knowledge has emerged as a growing challenge in recent years. The need to preserve and transfer nuclear knowledge is compounded by recent trends such as ageing of the nuclear workforce, declining student numbers in nuclear related fields, and the threat of losing accumulated nuclear knowledge. (author)

  11. Calibration curves for biological dosimetry

    Guerrero C, C.; Brena V, M. . E-mail cgc@nuclear.inin.mx

    2004-01-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of 60 Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  12. Code for Internal Dosimetry (CINDY)

    Strenge, D.L.; Peloquin, R.A.; Sula, M.J.; Johnson, J.R.

    1990-10-01

    The CINDY (Code for Internal Dosimetry) Software Package has been developed by Pacific Northwest Laboratory to address the Department of Energy (DOE) Order 5480.11 by providing the capabilities to calculate organ dose equivalents and effective dose equivalents using the approach of International Commission on Radiological Protection (ICRP) 30. The code assist in the interpretation of bioassay data, evaluates committed and calendar-year doses from intake or bioassay measurement data, provides output consistent with revised DOE orders, is easy to use, and is generally applicable to DOE sites. Flexible biokinetics models are used to determine organ doses for annual, 50-year, calendar-year, or any other time-point dose necessary for chronic or acute intakes. CINDY is an interactive program that prompts the user to describe the cases to be analyzed and calculates the necessary results for the type of analysis being performed. Four types of analyses may be specified. 92 figs., 10 tabs

  13. Development of radiation biological dosimetry

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil; Son, Young Sook; Kim, Soo Kwan; Jang, Won Suk; Le, Sun Joo; Jee, Young Heun; Jung, Woo Jung

    1999-04-01

    Up until now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline (triage) to be able to be treated the victims as fast as possible. We established the premature chromosome condensation assay and apoptotic fragment assay which was the significant relationship between dose and cell damages to evaluate the irradiation dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with conventional chromosome aberration assay and micronuclei assay

  14. Advanced materials in radiation dosimetry

    Bruzzi, M; Nava, F; Pini, S; Russo, S

    2002-01-01

    High band-gap semiconductor materials can represent good alternatives to silicon in relative dosimetry. Schottky diodes made with epitaxial n-type 4 H SiC and Chemical Vapor Deposited diamond films with ohmic contacts have been exposed to a sup 6 sup 0 Co gamma-source, 20 MeV electrons and 6 MV X photons from a linear accelerator to test the current response in on-line configuration in the dose range 0.1-10 Gy. The released charge as a function of the dose and the radiation-induced current as a function of the dose-rate are found to be linear. No priming effects have been observed using epitaxial SiC, due to the low density of lattice defects present in this material.

  15. Metabolism and dosimetry of tritium

    Hill, R.L.; Johnson, J.R.

    1993-01-01

    This document was prepared as a review of the current knowledge of tritium metabolism and dosimetry. The physical, chemical, and metabolic characteristics of various forms of tritium are presented as they pertain to performing dose assessments for occupational workers and for the general public. For occupational workers, the forms of tritium discussed include tritiated water, elemental tritium gas, skin absorption from elemental tritium gas-contaminated surfaces, organically bound tritium in pump oils, solvents and other organic compounds, metal tritides, and radioluminous paints. For the general public, age-dependent tritium metabolism is reviewed, as well as tritiated water, elemental tritium gas, organically bound tritium, organically bound tritium in food-stuffs, and tritiated methane. 106 refs

  16. Patient dosimetry in diagnostic radiology

    Rweyemamu, M.

    2013-04-01

    The objective of this project was to review patient dosimetry aiming at reducing the patient dose during diagnostic procedures while maintaining the best image quality in order to protect patients from ionizing radiation. CT examination was selected in this study to represent imaging protocols with high patient doses used in diagnostic radiology. Dosimetric parameters in CT which are CTDI, CTDIW, DLP, MSAD, organ dose and effective dose were discussed. Parameters such as tube current, tube voltage, filtration, scan volume and slice thickness were found to affect patient dose, therefore proper management of these factors was recommended. For optimization of protection of the patient, application of the “as low as reasonably achievable” (ALARA) principle was recommended as an important key for avoiding overexposure and minimizing patient doses. Also it was recommended that CT examinations should be performed if and only if is the only suitable option when weighed against other options which do not involve ionizing radiation exposure. (author)

  17. Recommendations about criticality accident dosimetry

    1975-07-01

    The aims of criticality accident dosimetry and the characteristics peculiar to a critical burst being defined, the requirements to be fulfilled by a dosimetric system applied to this type of measurements are presented. The devices chosen by the C.E.A. Radiation Survey Divisions, simple and cheap, are described along with the main processes to be carried out in order to evaluate doses after an accident. The apparatus necessary for detector counting and the directions for use are presented in detail, allowing standardization of measurements. A set of linear formula enables to obtain, from these measurements, all required informations about neutron fluences and spectra, along with the suitable components of the dose at the irradiated people locations [fr

  18. Audits for advanced treatment dosimetry

    Ibbott, G. S.; Thwaites, D. I.

    2015-01-01

    Radiation therapy has advanced rapidly over the last few decades, progressing from 3D conformal treatment to image-guided intensity modulated therapy of several different flavors, both 3D and 4D and to adaptive radiotherapy. The use of intensity modulation has increased the complexity of quality assurance and essentially eliminated the physicist's ability to judge the validity of a treatment plan, even approximately, on the basis of appearance and experience. Instead, complex QA devices and procedures are required at the institutional level. Similarly, the assessment of treatment quality through remote and on-site audits also requires greater sophistication. The introduction of 3D and 4D dosimetry into external audit systems must follow, to enable quality assurance systems to perform meaningful and thorough audits.

  19. Audits for advanced treatment dosimetry

    Ibbott, G S; Thwaites, D I

    2015-01-01

    Radiation therapy has advanced rapidly over the last few decades, progressing from 3D conformal treatment to image-guided intensity modulated therapy of several different flavors, both 3D and 4D and to adaptive radiotherapy. The use of intensity modulation has increased the complexity of quality assurance and essentially eliminated the physicist's ability to judge the validity of a treatment plan, even approximately, on the basis of appearance and experience. Instead, complex QA devices and procedures are required at the institutional level. Similarly, the assessment of treatment quality through remote and on-site audits also requires greater sophistication. The introduction of 3D and 4D dosimetry into external audit systems must follow, to enable quality assurance systems to perform meaningful and thorough audits

  20. Development of radiation biological dosimetry

    Cho, Chul Koo; Kim, Tae Hwan; Lee, Yun Sil; Son, Young Sook; Kim, Soo Kwan; Jang, Won Suk; Le, Sun Joo; Jee, Young Heun; Jung, Woo Jung

    1999-04-01

    Up until now, only a few methods have been developed for radiation biological dosimetry such as conventional chromosome aberration and micronucleus in peripheral blood cell. However, because these methods not only can be estimated by the expert, but also have a little limitation due to need high technique and many times in the case of radiation accident, it is very difficult to evaluate the absorbed dose of victims. Therefore, we should develop effective, easy, simple and rapid biodosimetry and its guideline (triage) to be able to be treated the victims as fast as possible. We established the premature chromosome condensation assay and apoptotic fragment assay which was the significant relationship between dose and cell damages to evaluate the irradiation dose as correct and rapid as possible using lymphocytes and crypt cells, and compared with conventional chromosome aberration assay and micronuclei assay.

  1. Updating radon daughter bronchial dosimetry

    Harley, N.H.; Cohen, B.S.

    1990-01-01

    It is of value to update radon daughter bronchial dosimetry as new information becomes available. Measurements have now been performed using hollow casts of the human bronchial tree with a larynx to determine convective or turbulent deposition in the upper airways. These measurements allow a more realistic calculation of bronchial deposition by diffusion. Particle diameters of 0.15 and 0.2 μm were used which correspond to the activity median diameters for radon daughters in both environmental and mining atmospheres. The total model incorporates Yeh/Schum bronchial morphometry, deposition of unattached and attached radon daughters, build up and decay of the daughters and mucociliary clearance. The alpha dose to target cells in the bronchial epithelium is calculated for the updated model and compared with previous calculations of bronchial dose

  2. Neutron excitation function guide for reactor dosimetry

    Gritzay, O.; Vlasov, M.; Chervonna, L.; Klimova, N.; Kolota, G.; Zerkin, V.

    2002-01-01

    Neutron Excitation Function Guide for Reactor Dosimetry (NEFGRD) has been prepared in the Ukrainian Nuclear Data Center (UKRNDC) using ZVV 9.2 code for graphical data presentation. The data can be retrieved through Web or obtained on CD-ROM or as hard copy report. NEFGRD contains graphical and text information for 56 nuclides (81 dosimetry reactions). Each reaction is provided by the information part and several graphical function blocks (from one to nine). (author)

  3. Tenth DOE workshop on personnel neutron dosimetry

    1984-06-01

    The purpose of this workshop is to promote the international exchange of information on neutron dosimetry. The development of an accurate real-time dosemeter is an immediate need which must be met. Assessment of the neutron dose equivalent at low doses with a reasonable degree of accuracy must be accomplished to provide validity to exposure records. These and other aspects of personal neutron dosimetry are discussed. Separate abstracts have been prepared for each paper for inclusion in the Energy Data Base

  4. Computerized dosimetry management systems within EDF

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  5. Neutron personal dosimetry: state-of-art

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  6. HUD GIS Boundary Files

    Department of Housing and Urban Development — The HUD GIS Boundary Files are intended to supplement boundary files available from the U.S. Census Bureau. The files are for community planners interested in...

  7. Dosimetry control for radiation processing - basic requirements and standards

    Ivanova, M.; Tsrunchev, Ts.

    2004-01-01

    A brief review of the basic international codes and standards for dosimetry control for radiation processing (high doses dosimetry), setting up a dosimetry control for radiation processing and metrology control of the dosimetry system is made. The present state of dosimetry control for food processing and the Bulgarian long experience in food irradiation (three irradiation facilities are operational at these moment) are presented. The absence of neither national standard for high doses nor accredited laboratory for calibration and audit of radiation processing dosimetry systems is also discussed

  8. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  9. Dosimetry and operation of irradiation facilities

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  10. Cellular dosimetry in nuclear medicine imaging: training

    Gardin, I.; Faraggi, M.; Stievenart, J.L.; Le Guludec, D.; Bok, B.

    1998-01-01

    The radionuclides used in nuclear medicine imaging emit not only diagnostically useful photons, but also energy electron emissions, responsible for dose heterogeneity at the cellular level. The mean dose delivered to the cell nucleus by electron emissions of 99m Tc, 123 I, 111 In, 67 Ga, and 201 Tl, has been calculated, for the cell nucleus, a cytoplasmic and a cell membrane distribution of radioactivity. This model takes into account both the self-dose which results from the radionuclide located in the target cell, and the cross-dose, which comes from the surrounding cells. The results obtained by cellular dosimetry (D cel ) have been compared with those obtained with conventional dosimetry (D conv ), by assuming the same amount of radioactivity per cell. Cellular dosimetry shows, for a cytoplasmic and a cell membrane distributions of radioactivity, that the main contribution to the dose to the cell nucleus, comes from the surrounding cells. On the other hand, for a cell nucleus distribution of radioactivity, the self-dose is not negligible and may be the main contribution. The comparison between cellular and conventional dosimetry shows that D cel /D conv ratio ranges from 0.61 and O.89, in case of a cytoplasmic and a cell membrane distributions of radioactivity, depending on the radionuclide and cell dimensions. Thus, conventional dosimetry slightly overestimates the mean dose to the cell nucleus. On the other hand, D cel /D conv ranges from 1.1 to 75, in case of a cell nucleus distribution of radioactivity. Conventional dosimetry may strongly underestimates the absorbed dose to the nucleus, when radioactivity is located in the nucleus. The study indicates that in nuclear medicine imaging, cellular dosimetry may lead to a better understanding of biological effects of radiopharmaceuticals. (authors)

  11. Dosimetry of blood irradiator - 2000

    Mhatre, Sachin G.V.; Shinde, S.H.; Bhat, R.M.; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Full text: Blood transfusion to an immunodeficient or immunosuppressed patient has a high risk involved due to occurrence of Transfusion Graft Versus Host Disease (T-GVHD). In order to eliminate this problem, blood is routinely exposed to ionizing radiation (gamma) prior to transfusion. Doses ranging from 15 Gy to 50 Gy can prevent T-GVHD. Aim of the present work was to perform dosimetry of 60 Co Blood Irradiator-2000 developed by Board of Radiation and isotope Technology (BRIT), India; using FBX dosimetric system. Dose-rate measured by FBX dosimeter was intercompared with Fricke dosimeter, which is a Reference Standard dosimeter. Experiments included measurement of dose-rate at the centre of irradiation volume, dose mapping in the central vertical plane within the irradiation volume and measurement of average dose received by blood sample using blood bags filled with FBX dosimeter by simulating actual irradiation conditions. During irradiation, the sample chamber is retracted into a cylindrical source cage, so that the sample is irradiated from all sides uniformly. Blood irradiator-2000 has sample rotation facility for increasing the dose uniformity during irradiation. The performance of this was investigated by measuring the central vertical plane dose profile in stationary state as well in rotation using the sample rotation facility (60 rpm). FBX being an aqueous dosimetric system fills container of irregular shape being irradiated hence can be used to integrate the dose over the volume. Dose-rate measured by FBX dosimeter was intercompared with Fricke dosimeter, which was in good agreement. Average dose-rate at the centre of irradiation volume and within the blood bag was measured by FBX and Fricke dosimeters. It was observed that dose profiles measured by FBX and Fricke dosimeters agreed within ± 2%. Dose uniformity within the irradiation volume was found to reduce from 21% to 17% when the sample rotation facility was used. Thus, it is suggested by the

  12. Current concepts in lung dosimetry. Proceedings of a special workshop

    Fisher, D.R.

    1983-02-01

    The proceedings of the first special workshop on Lung Dosimetry include the presentation of many new concepts and the reassessment of traditional ideas in lung dosimetry and risk evaluation. Separate abstracts were prepared for the 21 papers in the proceedings

  13. Personnel neutron dosimetry at Department of Energy facilities

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  14. Database to manage personal dosimetry Hospital Universitario de La Ribera

    Melchor, M.; Martinez, D.; Asensio, M.; Candela, F.; Camara, A.

    2011-01-01

    For the management of professionally exposed personnel dosimetry, da La are required for the use and return of dosimeters. in the Department of Radio Physics and Radiation Protection have designed and implemented a database management staff dosimetry Hospital and Area Health Centers. The specific objectives were easily import data from the National Center dosimetric dosimetry, consulting records in a simple dosimetry, dosimeters allow rotary handle, and also get reports from different periods of time to know the return data for users, services, etc.

  15. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    Cooper, J R

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  16. Experimental verification of internal dosimetry calculations. Annual progress report

    1980-05-01

    During the past year a dosimetry research program has been established in the School of Nuclear Engineering at the Georgia Institute of Technology. The major objective of this program has been to provide research results upon which a useful internal dosimetry system could be based. The important application of this dosimetry system will be the experimental verification of internal dosimetry calculations such as those published by the MIRD Committee

  17. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    COOPER, J.R.

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual

  18. Neutron dosimetry using electrochemical etching

    Su, S.J.; Stillwagon, G.B.; Morgan, K.Z.

    1977-01-01

    Registration of α-tracks and fast-neutron-induced recoils tracks by the electrochemical etching technique as applied to sensitive polymer foils (e.g., polycarbonate) provides a simple, sensitive and inexpensive means of fast neutron personnel dosimetry as well as a valuable research tool for microdosimetry. When tracks were amplified by our electrochemical technique and the etching results compared with conventional etching technique a striking difference was noted. The electrochemically etched tracks were of much larger diameter (approx. 100 μm) and gave superior contrast. Two optical devices--the transparency projector and microfiche reader--were adapted to facilitate counting of the tracks appearing on our polycarbonate foils. The projector produced a magnification of 14X for a screen to projector distance of 5.0 meter and read's magnification was 50X. A Poisson distribution was determined for the number of tracks located in a particular area of the foil and experimentally verified by random counting of quarter sections of the microfiche reader screen. Finally, in an effort to determine dose equivalent (rem), a conversion factor is being determined by finding the sensitivity response (tracks/neutron) of recoil particle induced tracks as a function of monoenergetic fast neutrons and comparing results with those obtained by others

  19. Radiosynoviorthesis. Clinical and preclinical dosimetry

    Torres Berdeguez, Mirta B; Ayra Pardo, Fernando E

    2006-01-01

    Accurate calculation of internal dose estimates in the Radiosynoviorthesis treatment requires several steps of analysis. The use of animal models (rabbits) to predict human kinetics and dosimetry is an essential first step in the evaluation of new radiocolloids, but involves many uncertainties. There is no gold standard method for extrapolating animal data to humans. Nonetheless, human dose estimates based on animal data are considered to be reasonable approximations to be used for proceeding with dose estimates based on human data, which are ultimately used to assess the safety and efficacy evaluations of radiopharmaceuticals, and continues to be an important element in the radiopharmaceutical approval process. The obtained absorbed dose profiles versus synovial tissue, bone and articular cartilage depth will permit the specialist to prescribe the adequate dose of radionuclide to treat rheumatoid arthritis in medium and large joints without expose the healthy structures of the synovial joint to an excessive and unnecessary irradiation risk, eliminating the fixed dose and fixed radionuclides for each joints (Author)

  20. Oesophageal dosimetry during cardial catheterisation

    Noel, A.; Aletti, P.; Claudon, M.; Hoeffel, J.C.; Lostette, Y.

    1981-01-01

    The purpose of this two-fold study has been the measurement of absorbed dose to patients during cardiac catheterization. Radiothermoluminescence (RTL), the method of choice for dosimetry in vivo, has been used extensively in this work. The first part of the study involved 49 unselected patients. A ratio (the equivalent fluoroscopic time) was established between the duration of fluoroscopy and the length of film exposed; this simplified the calculation of patient-dose. The dose absorbed in a central region of the mediastinum was designated the heart dose and was calculated by means of a formula in which the variables were fluoroscopic time and length of film. It was shown that the dose absorbed was unrelated to the thoracic thickness of the patients examined. The second part of the study was confined to 15 selected patients; infants and young children could not be included because of the requirement to insert an oesophageal catheter. The catheter was made of flexible polyethylene with a lithium fluoride tip enabling measurement of the dose within the oesophagus. Employing this technique, we were able to confirm the accuracy of our earlier study by comparing the measured oesophageal dose with the estimated heart dose [fr

  1. Rational system of radiation dosimetry

    Katoh, K.; Tada, J.

    1996-01-01

    Radiation doses are the most important subject to the sciences relating to the effects of ionizing radiation on matter. Since any science at all must stand on the quantitative description of causality, uses of physical quantities as the measures are indispensable. The current system of radiation dosimetry is built on the fundamental dose of the absorbed dose, which is defined as the 'energy imparted' density, and for practical convenience various weighted absorbed doses are introduced as subsidiary. However, it has been pointed out that these quantities lack adequacy inherently as a measure of causes, in addition to the insufficiency of the specification of the concept. Firstly, separation of the quantities of radiation field and of the dose is not possible, since both quantities are deeply related to the same microscopic constituents, i.e., electrons. Secondly, the value of the absorbed dose cannot be fixed at the moment of irradiation. Since the absorbed dose is a quantity of interaction product of radiation and matter, the values of the dose cannot be fixed instantaneously. Thirdly, it is not easy to envision the physical entity of the quantity from the definition. The form of existence of the 'imparted' energy is not clear in the current definition. These defects can not be removed as long as an interaction product is adopted as the dose quantity. In this paper, the authors present a prescription to solve these problems. (author)

  2. Ionizing radiations, detection, dosimetry, spectrometry

    Blanc, D.

    1997-10-01

    A few works in French language are devoted to the detection of radiations. The purpose of this book is to fill a gap.The five first chapters are devoted to the properties of ionizing radiations (x rays, gamma rays, leptons, hadrons, nuclei) and to their interactions with matter. The way of classification of detectors is delicate and is studied in the chapter six. In the chapter seven are studied the statistics laws for counting and the spectrometry of particles is treated. The chapters eight to thirteen study the problems of ionization: charges transport in a gas, ionization chambers (theory of Boag), counters and proportional chambers, counters with 'streamers', chambers with derive, spark detectors, ionization chambers in liquid medium, Geiger-Mueller counters. The use of a luminous signal is the object of the chapters 14 to 16: conversion of a luminous signal in an electric signal, scintillators, use of the Cerenkov radiation. Then, we find the neutron detection with the chapter seventeen and the dosimetry of particles in the chapter eighteen. This book does not pretend to answer to specialists questions but can be useful to physicians, engineers or physics teachers. (N.C.)

  3. ZZ MATXSLIBJ33, JENDL-3.3 based, 175 N-42 photon groups (VITAMIN-J) MATXS library for discrete ordinates multi-group

    Kosako, K.; Yamano, N.; Fukahori, T.; Shibata, K.; Hasegawa, A.

    2006-01-01

    1 - Description of program or function: JENDL-3.3 based, 175 neutron-42 photon groups (VITAMIN-J) MATXS library for discrete ordinates multi-group transport codes. Format: MATXS. Number of groups: 175 neutron, 42 gamma-ray. Nuclides: 337 nuclides contained in JENDL-3.3: H-1, H-2, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-Nat, N-14, N-15, O-16, F-19, Na-23, Mg-24, Mg-25, Mg-26, Al-27, Si-28, Si-29, Si-30, P-31, S-32, S-33, S-34, S-36, Cl-35, Cl-37, Ar-40, K-39, K-40, K-41, Ca-40, Ca-42, Ca-43, Ca-44, Ca-46, Ca-48, Sc-45, Ti-46, Ti-47, Ti-48, Ti-49, Ti-50, V-Nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Cu-63, Cu-65, Ga-69, Ga-71, Ge-70, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-79, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-87, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-91, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, Mo-98, Mo-99, Mo-100, Tc-99, Ru-96, Ru-98, Ru-99, Ru-100, Ru-101, Ru-102, Ru-103, Ru-104, Ru-106, Rh-103, Rh-105, Pd-102, Pd-104, Pd-105, Pd-106, Pd-107, Pd-108, Pd-110, Ag-107, Ag-109, Ag-110m, Cd-106, Cd-108, Cd-110, Cd-111, Cd-112, Cd-113, Cd-114, Cd-116, In-113, In-115, Sn-112, Sn-114, Sn-115, Sn-116, Sn-117, Sn-118, Sn-119, Sn-120, Sn-122, Sn-123, Sn-124, Sn-126, Sb-121, Sb-123, Sb-124, Sb-125, Te-120, Te-122, Te-123, Te-124, Te-125, Te-126, Te-127m, Te-128, Te-129m, Te-130, I-127, I-129, I-131, Xe-124, Xe-126, Xe-128, Xe-129, Xe-130, Xe-131, Xe-132, Xe-133, Xe-134, Xe-135, Xe-136, Cs-133, Cs-134, Cs-135, Cs-136, Cs-137, Ba-130, Ba-132, Ba-134, Ba-135, Ba-136, Ba-137, Ba-138, Ba-140, La-138, La-139, Ce-140, Ce-141, Ce-142, Ce-144, Pr-141, Pr-143, Nd-142, Nd-143, Nd-144, Nd-145, Nd-146, Nd-147, Nd-148, Nd-150, Pm-147, Pm-148, Pm-148m, Pm-149, Sm-144, Sm-147, Sm-148, Sm-149, Sm-150, Sm-151, Sm-152, Sm-153, Sm-154, Eu-151, Eu-152, Eu-153, Eu-154, Eu-155, Eu

  4. Chemical dosimetry system for criticality accidents.

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.

  5. Dosimetry methods for fuels, cladding and structural materials

    Roettger, H.

    1980-01-01

    This volume of the proceedings of the symposium on reactor dosimetry covers the following topics: the metallurgy and dosimetry interface, radiation damage correlations of structural materials and damage analyses techniques, dosimetry for fusion materials, light water reactor pressure vessel surveillance in practice and irradiation experiments, fast reactor and reseach reactor characterization

  6. Sixth international radiopharmaceutical dosimetry symposium: Proceedings. Volume 2

    S.-Stelson, A.T. [ed.] [comp.; Stabin, M.G.; Sparks, R.B. [eds.; Smith, F.B. [comp.

    1999-01-01

    This conference was held May 7--10 in Gatlinburg, Tennessee. The purpose of this conference was to provide a multidisciplinary forum for exchange of state-of-the-art information on radiopharmaceutical dosimetry. Attention is focused on the following: quantitative analysis and treatment planning; cellular and small-scale dosimetry; dosimetric models; radiopharmaceutical kinetics and dosimetry; and animal models, extrapolation, and uncertainty.

  7. Updating the INDAC computer application of internal dosimetry

    Bravo Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Sanudo, E.; Serrano Calvo, E.

    2013-01-01

    The initial objective of this project is to expand the application INDAC currently used in internal dosimetry services of the Spanish nuclear power plants and Tecnatom for estimating the effective doses of internal dosimetry of workers in direct action. or in-vivo dosimetry. (Author)

  8. Development and implementation of own software for dosimetry multichannel film

    Jimenez Feltstrom, D.; Reyes Garcia, R.; Luis Simon, F. J.; Carrasco Herrera, M.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-01-01

    The objective of this work is to develop its own software for multichannel film dosimetry Radiochromic EBT2. Compare the results obtained with its use in multichannel and single-channel dosimetry. Check that the multi-channel dosimetry eliminates much of the artifacts caused by dirt, fingerprints, scratches, etc. Radiochromic in film and scanner devices. (Author)

  9. Provider of Services File

    U.S. Department of Health & Human Services — The POS file consists of two data files, one for CLIA labs and one for 18 other provider types. The file names are CLIA and OTHER. If downloading the file, note it...

  10. TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

    Garcia, Marie-Paule, E-mail: marie-paule.garcia@univ-brest.fr; Villoing, Daphnée [UMR 1037 INSERM/UPS, CRCT, 133 Route de Narbonne, 31062 Toulouse (France); McKay, Erin [St George Hospital, Gray Street, Kogarah, New South Wales 2217 (Australia); Ferrer, Ludovic [ICO René Gauducheau, Boulevard Jacques Monod, St Herblain 44805 (France); Cremonesi, Marta; Botta, Francesca; Ferrari, Mahila [European Institute of Oncology, Via Ripamonti 435, Milano 20141 (Italy); Bardiès, Manuel [UMR 1037 INSERM/UPS, CRCT, 133 Route de Narbonne, Toulouse 31062 (France)

    2015-12-15

    Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry

  11. PC Graphic file programing

    Yang, Jin Seok

    1993-04-01

    This book gives description of basic of graphic knowledge and understanding and realization of graphic file form. The first part deals with graphic with graphic data, store of graphic data and compress of data, programing language such as assembling, stack, compile and link of program and practice and debugging. The next part mentions graphic file form such as Mac paint file, GEM/IMG file, PCX file, GIF file, and TIFF file, consideration of hardware like mono screen driver and color screen driver in high speed, basic conception of dithering and conversion of formality.

  12. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  13. Medical radiation dosimetry with radiochromic film

    Butson, M.J.; Cancer Services, NSW; Cheung, T.; Yu, P.K.N.; Metcalfe, P.

    2004-01-01

    Full text: Photon, electron and proton radiation are used extensively for medical purposes in diagnostic and therapeutic procedures. Dosimetry of these radiation sources can be performed with radiochromic films, devices that have the ability to produce a permanent visible colour change upon irradiation. Within the last ten years, the use of radiochromic films has expanded rapidly in the medical world due to commercial products becoming more readily available, higher sensitivity films and technology advances in imaging which have allowed scientists to use two-dimensional dosimetry more accurately and inexpensively. Radiochromic film dosimeters are now available in formats, which have accurate dose measurement ranges from less than 1 Gy up to many kGy. A relatively energy independent dose response combined with automatic development of radiochromic film products has made these detectors most useful in medical radiation dosimetry. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  14. Individual Dosimetry for High Energy Radiation Fields

    Spurny, F.

    1999-01-01

    The exposure of individuals on board aircraft increased interest in individual dosimetry in high energy radiation fields. These fields, both in the case of cosmic rays as primary radiation and at high energy particle accelerators are complex, with a large diversity of particle types, their energies, and linear energy transfer (LET). Several already existing individual dosemeters have been tested in such fields. For the component with high LET (mostly neutrons) etched track detectors were tested with and without fissile radiators, nuclear emulsions, bubble detectors for both types available and an albedo dosemeter. Individual dosimetry for the low LET component has been performed with thermoluminescent detectors (TLDs), photographic film dosemeters and two types of electronic individual dosemeters. It was found that individual dosimetry for the low LET component was satisfactory with the dosemeters tested. As far as the high LET component is concerned, there are problems with both the sensitivity and the energy response. (author)

  15. Dosimetry in support of wholesomeness studies

    Jarrett, R.D.; Halliday, J.W.

    1979-01-01

    Interest in dosimetry procedures in the context of a large-scale processing situation exceeds the purely documentary aspects of this report. The numerous combinations afforded by the various types, strengths and configurations of irradiation sources and the possibilities for various conveyors and other facility design factors impacting on irradiation logistics render a completely general treatment of dosimetry procedures in such instances almost impossible. While the exact combination of these various factors represented by the irradiation facilities at NARADCOM may be duplicated nowhere else, the dosimetry procedures documented in this report offer both experience and solutions that might be more generally useful. Therefore, this report complements and supplements more general discussions found in the literature and cited in the text

  16. Survey of international personnel radiation dosimetry programs

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  17. Radiation dosimetry activities in the Netherlands

    Broerse, J.J.; Mijnheer, B.J.

    1986-07-01

    The Netherlands Commission for Radiation Dosimetry (NCS) was officially established on 3 September 1982 with the aim of promoting the appropriate use of dosimetry of ionizing radiation both for scientific research and practical applications. The present report provides a compilation of the dosimetry acitivities and expertise available in the Netherlands, based on the replies to a questionnaire mailed under the auspices of the NCS and might suffer from some incompleteness in specific details. The addresses of the Dutch groups with the names of the scientists are given. Individual scientists, not connected with a scientific group, hospital or organization have not been included in this list. Also the names of commercial firms producing dosimetric systems have been omitted. (Auth.)

  18. Dosimetry systems for radiation processing in Japan

    Tamura, Naoyuki

    1995-01-01

    The present situation of dosimetry systems for radiation processing industry in Japan is reviewed. For gamma-rays irradiation the parallel-plate ionization chamber in TRCRE, JAERI has been placed as a reference standard dosimeter for processing-level dose. Various solid and liquid chemical dosimeters are used as routine dosimeters for gamma processing industries. Alanine dosimeters is used for the irradiation purpose which needs precise dosimetry. For electron-beam irradiation the electron current density meter and the total absorption calorimeter of TRCRE are used for the calibration of routine dosimeters. Plastic film dosimeters, such as cellulose triacetate and radiochromic dye are used as routine dosimeters for electron processing industries. When the official traceability systems for processing-level dosimetry now under investigation is completed, the ionization chamber of TRCRE is expected to have a role of the primary standard dosimeter and the specified alanine dosimeter will be nominated for the secondary or reference standard dosimeter. (author)

  19. Bayesian Methods for Radiation Detection and Dosimetry

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  20. Czech results at criticality dosimetry intercomparison 2002.

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.

  1. Performance testing of UK personal dosimetry laboratories

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  2. Performance testing of UK personal dosimetry laboratories

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  3. Role of dosimetry in radiation processing applications

    Mehta, Kishor

    2001-01-01

    Today, radiation processing is a growing technology offering potential technological advantages as well as enhanced safety and economy. It is expanding on two fronts: the variety of applications is exploding as well as the sources of radiation. And with that comes the necessary advances in dosimetry. However, the success of the technology still depends on the assertion that the irradiated products are reliable and safe, whether they are health care products or cables and wires. And this is best assured through quality assurance programmes. The key element in QA in radiation processing is a well-characterised, reliable dosimetry that is traceable to the international measurement system. Traceability is the foundation for international acceptance of the irradiated products; and with international trade of irradiated products on the rise, it becomes absolutely critical. It is thus vital that the industry recognises this pivotal position of good dosimetry and the role a national standards laboratory plays in that connection. (author)

  4. Reactor Dosimetry State of the Art 2008

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    Oral session 1: Retrospective dosimetry. Retrospective dosimetry of VVER 440 reactor pressure vessel at the 3rd unit of Dukovany NPP / M. Marek ... [et al.]. Retrospective dosimetry study at the RPV of NPP Greifswald unit 1 / J. Konheiser ... [et al.]. Test of prototype detector for retrospective neutron dosimetry of reactor internals and vessel / K. Hayashi ... [et al.]. Neutron doses to the concrete vessel and tendons of a magnox reactor using retrospective dosimetry / D. A. Allen ... [et al.]. A retrospective dosimetry feasibility study for Atucha I / J. Wagemans ... [et al.]. Retrospective reactor dosimetry with zirconium alloy samples in a PWR / L. R. Greenwood and J. P. Foster -- Oral session 2: Experimental techniques. Characterizing the Time-dependent components of reactor n/y environments / P. J. Griffin, S. M. Luker and A. J. Suo-Anttila. Measurements of the recoil-ion response of silicon carbide detectors to fast neutrons / F. H. Ruddy, J. G. Seidel and F. Franceschini. Measurement of the neutron spectrum of the HB-4 cold source at the high flux isotope reactor at Oak Ridge National Laboratory / J. L. Robertson and E. B. Iverson. Feasibility of cavity ring-down laser spectroscopy for dose rate monitoring on nuclear reactor / H. Tomita ... [et al.]. Measuring transistor damage factors in a non-stable defect environment / D. B. King ... [et al.]. Neutron-detection based monitoring of void effects in boiling water reactors / J. Loberg ... [et al.] -- Poster session 1: Power reactor surveillance, retrospective dosimetry, benchmarks and inter-comparisons, adjustment methods, experimental techniques, transport calculations. Improved diagnostics for analysis of a reactor pulse radiation environment / S. M. Luker ... [et al.]. Simulation of the response of silicon carbide fast neutron detectors / F. Franceschini, F. H. Ruddy and B. Petrović. NSV A-3: a computer code for least-squares adjustment of neutron spectra and measured dosimeter responses / J. G

  5. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images.

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity.

  6. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images*

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    Objective This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and Methods A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. Results With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. PMID:25741101

  7. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images

    Leal Neto, Viriato; Vieira, Jose Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    Objective: this article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and methods: a software called DoRadIo (Dosimetria das Radiacoes Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C ⧣ programming language. Results: with the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion: the user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. (author)

  8. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images

    Leal Neto, Viriato, E-mail: viriatoleal@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Vieira, Jose Wilson [Universidade Federal de Pernambuco (UPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-09-15

    Objective: this article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and methods: a software called DoRadIo (Dosimetria das Radiacoes Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C ⧣ programming language. Results: with the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion: the user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. (author)

  9. Individual dosimetry of workers and patients: implementation and perspectives

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  10. Automation at NRCN Dosimetry Laboratory

    Abraham, A.; Arad, I.; Mesing, M.; Levinson, S.; Weinstein, M.; Pelled, O.; Broida, A.; German, U.

    2014-01-01

    Running a dosimetric service based on TLD technology such as at the Nuclear Research Centre Negev (NRCN) requires a large group of workers to carry out simple mechanical actions such as opening and closing TLD badges, placing and removal of TLD cards from the badges and operating the TLD reader. These actions can be automated to free human resources for other assignments and to improve the quality assurance. At NRCN a project was undertaken to design and build a robotic system based on a manipulator arm. The design was based on the experience achieved with an earlier prototype (1,2). The system stores the TLD badges in special designed boxes, which are transported and stored in computer defined bins. The robotic arm loads and unloads TLD cards to the badges, and loads/unloads the cards to a magazine for the TLD reader. At the Nuclear Research Center Negev (NRCN) each badge is assigned to a specific worker and bears a sticker containing the worker's personal details, also in a machine readable form (barcode). In order to establish a proper QA check, a barcode reader records the information on the badge and on the TLD card placed in this badge and checks their compatibility with the information contained in the main database. Besides the TLD cards loading/unloading station, there is a contamination check station, a cards cleaning station and a UV irradiation box used to reduce the history dependent residual dose. The system was installed at the NRCN dosimetry laboratory It was successfully tested for several hundreds of cycles and will become operational in the first quarter of 2014. As far as we know, there is no similar product available for automatic handling in a TLD laboratory

  11. Thermoluminescent dosimetry in computed tomography

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  12. Dosimetry of the respiratory tract

    Roy, M.

    1996-01-01

    A new dosimetric model of the human respiratory tract has been recently recommended by the International Commission on Radiological Protection, in ICRP Publication 66. This model was intended to update the previous lung model of the Task Group on Lung Dynamics that was adopted by ICRP in Publication 30. With this aim, extensive reviews of the available knowledge were made for anatomy and physiology of the respiratory tract and for deposition, clearance and biological effects of inhaled radionuclides. Finally, expanded dosimetry requirements resulted in a widely different approach from the former model. The main features of the new model are the followings: instead of calculating the average dose to the total mass of blood filled lung, the model takes account of differences in radiosensitivity of the venous respiratory tract tissues. It applies not only to adult workers but also to all members of the population, and provides reference values for children aged 3 months, 1, 5, 10, and 15 years, and adults. Deposition modelling of airborne gases and aerosols associates age dependent breathing rates, airway dimensions and physical activity, to particle size, density and chemical form of inhaled material. Clearance results of competition between mechanical transport clearance and absorption to blood. At each step of the calculation, adjustment guidance is provided to account for use of exact values of particle sizes and specific dissolution rates of inhaled material in order to calculate their own parameter of retention in the airways, and to assess accurately doses to the respiratory tract. Possible influence of smoking, of respiratory tract diseases and of eventual exposure to airborne toxicants is also addressed. (author)

  13. Thermoluminescent dosimetry in computed tomography

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  14. Kinetics model for lutate dosimetry

    Lima, M.F.; Mesquita, C.H.

    2013-01-01

    The use of compartmental analysis to predict the behavior of drugs in the organism is considered the better option among numerous methods employed in pharmacodynamics. A six compartments model was developed to determinate the kinetic constants of 177Lu-DOTATATO biodistribution using data from one published study with 67 patients treated by PRRT (Peptide receptor radionuclide therapy) and followed by CT during 68,25 hours. The compartmental analysis was made using the software AnaComp®. The influence of the time pos-injection over the dose assessment was studied taking into account the renal excretion management by aminoacid coinfusion, whose direct effects persist in the first day. The biodistribution curve was split in five sectors: 0-0.25h; 0-3.25h; 3.25-24.25h; 24.25-68.25h and 3.25-68.25h. After the examination of that influence, the study was concentrated in separate the biodistribution curve in two phases. Phase 1: governed by uptake from the blood, considering the time pos-injection until 3.25h and phase 2: governed by renal excretion, considering the time pos-injection from 3.25h to 68.25h. The model considered the organs and tissues superposition in the CT image acquisition by sampling parameters as the contribution of the the activity concentration in blood and relation between the sizes of the whole body and measured organs. The kinetic constants obtained from each phase (1 and 2) were used in dose assessment to patients in 26 organs and tissues described by MIRD. Dosimetry results were in agreement with the available results from literature, restrict to whole body, kidneys, bone marrow, spleen and liver. The advantage of the proposed model is the compartmental method quickness and power to estimate dose in organs and tissues, including tumor that, in the most part, were not discriminate by voxels of phantoms built using CT images. (author)

  15. Kinetics model for lutate dosimetry

    Lima, M.F.; Mesquita, C.H., E-mail: mflima@ipen.br, E-mail: chmesqui@ipen.br [Instituto de Pesquisas Energeticas (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-11-01

    The use of compartmental analysis to predict the behavior of drugs in the organism is considered the better option among numerous methods employed in pharmacodynamics. A six compartments model was developed to determinate the kinetic constants of 177Lu-DOTATATO biodistribution using data from one published study with 67 patients treated by PRRT (Peptide receptor radionuclide therapy) and followed by CT during 68,25 hours. The compartmental analysis was made using the software AnaComp Registered-Sign . The influence of the time pos-injection over the dose assessment was studied taking into account the renal excretion management by aminoacid coinfusion, whose direct effects persist in the first day. The biodistribution curve was split in five sectors: 0-0.25h; 0-3.25h; 3.25-24.25h; 24.25-68.25h and 3.25-68.25h. After the examination of that influence, the study was concentrated in separate the biodistribution curve in two phases. Phase 1: governed by uptake from the blood, considering the time pos-injection until 3.25h and phase 2: governed by renal excretion, considering the time pos-injection from 3.25h to 68.25h. The model considered the organs and tissues superposition in the CT image acquisition by sampling parameters as the contribution of the the activity concentration in blood and relation between the sizes of the whole body and measured organs. The kinetic constants obtained from each phase (1 and 2) were used in dose assessment to patients in 26 organs and tissues described by MIRD. Dosimetry results were in agreement with the available results from literature, restrict to whole body, kidneys, bone marrow, spleen and liver. The advantage of the proposed model is the compartmental method quickness and power to estimate dose in organs and tissues, including tumor that, in the most part, were not discriminate by voxels of phantoms built using CT images. (author)

  16. Trends in light water reactor dosimetry programs

    Rahn, F.J.; Serpan, C.Z.; Fabry, A.; McElroy, W.N.; Grundl, J.A.; Debrue, J.

    1977-01-01

    Dosimetry programs and techniques play an essential role in the continued assurance of the safety and reliability of components of light water reactors. Primary concern focuses on the neutron irradiation embrittlement of reactor pressure vessels and methods by which the integrity of a pressure vessel can be predicted and monitored throughout its service life. Research in these areas requires a closely coordinated program which integrates the elements of the calculational and material sciences, the development of advanced dosimetric techniques and the use of benchmarks and validation of these methods. The paper reviews the status of the various international efforts in the dosimetry area

  17. Technical basis for internal dosimetry at Hanford

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ( 58 Co, 60 Co, 54 Mn, and 59 Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78 refs., 35 figs., 115 tabs

  18. Practical neutron dosimetry at high energies

    McCaslin, J.B.; Thomas, R.H.

    1980-10-01

    Dosimetry at high energy particle accelerators is discussed with emphasis on physical measurements which define the radiation environment and provide an immutable basis for the derivation of any quantities subsequently required for risk evaluation. Results of inter-laboratory dosimetric comparisons are reviewed and it is concluded that a well-supported systematic program is needed which would make possible detailed evaluations and inter-comparisons of instruments and techniques in well characterized high energy radiation fields. High-energy dosimetry is so coupled with radiation transport that it is clear their study should proceed concurrently

  19. Technical basis for internal dosimetry at Hanford

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78 refs., 35 figs., 115 tabs.

  20. Technical basis for internal dosimetry at Hanford

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1989-04-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64 refs., 42 figs., 118 tabs.