WorldWideScience

Sample records for isotopic method exploration

  1. The application of isotopic dating methods for prospection and exploration of nuclear raw material

    International Nuclear Information System (INIS)

    Komlev, L.V.; Anderson, E.B.

    1977-01-01

    Among the geological and geochemical methods for prospecting and searching the nuclear raw material, the isotope-dating methods determine the most important search criterion - the time of the ore-forming. The elaboration and use of these methods in uranium-ore regions reveal a series of geochemical epochs of uranium and thorium accumulation connected naturally with the history of geological evolution of the earth crust. The isotope-dating methods enable with confidence to establish the stages of tectono-magmatic activity resulting in the redistribution and the local concentration of uranium. The wide use of isotopic methods is a necessary condition for reasonable trends of the modern geological exploration [ru

  2. Lead isotope in mineral exploration

    International Nuclear Information System (INIS)

    Gulson, B.L.

    1986-01-01

    This book provides an up-to-date state-of-the-art review of lead isotopes in mineral exploration. Beginning with an historical review on suggested uses of lead isotopes in mineral exploration, the author then outlines the theoretical aspects of lead isotopes and illustrates that the method is based on well-known principles of radioactive decay, from which isotopic signatures for different styles of mineralization are derived. The varying isotopic signatures are then introduced. The major part of the book details over 40 case histories for base and precious metals, uranium and tin using sampling media such as sulfides, gossans, soils, weathered bedrock, vegetation and groundwaters. Advantages and disadvantages of each are discussed. Examples are given of the use of lead isotopes in testing conceptual models for exploration. The success rate and cost-effectiveness of the method are illustrated by actual exploration examples. Analytical advances which should lower the cost of the method and future uses are outlined. Many of the case histories use recently published or unpublished data, 27 tables of which are given in an appendix. Details of sampling, the methods for obtaining the isotope ratios, and a commercially-available integrated lead isotope service are also provided. (Auth.)

  3. New neutron-based isotopic analytical methods; An explorative study of resonance capture and incoherent scattering

    NARCIS (Netherlands)

    Perego, R.C.

    2004-01-01

    Two novel neutron-based analytical techniques have been treated in this thesis, Neutron Resonance Capture Analysis (NRCA), employing a pulsed neutron source, and Neutron Incoherent Scattering (NIS), making use of a cold neutron source. With the NRCA method isotopes are identified by the

  4. Isotope analysis in petroleum exploration

    International Nuclear Information System (INIS)

    Rodrigues, R.

    1982-01-01

    The study about isotopic analysis in petroleum exploration performed at Petrobras Research Center is showed. The results of the petroleum recuperation in same Brazilian basin and shelves are comented. (L.H.L.L.) [pt

  5. Method for separating isotopes

    International Nuclear Information System (INIS)

    Jepson, B.E.

    1976-01-01

    The invention comprises a method for separating different isotopes of elements from each other by contacting a feed solution containing the different isotopes with a macrocyclic polyether to preferentially form a macrocyclic polyether complex with the lighter of the different isotopes. The macrocyclic polyether complex is then separated from the lighter isotope depleted feed solution. A chemical separation of isotopes is carried out in which a constant refluxing system permits a continuous countercurrent liquid-liquid extraction. (LL)

  6. Stable isotope mass spectrometry in petroleum exploration

    International Nuclear Information System (INIS)

    Mathur, Manju

    1997-01-01

    The stable isotope mass spectrometry plays an important role to evaluate the stable isotopic composition of hydrocarbons. The isotopic ratios of certain elements in petroleum samples reflect certain characteristics which are useful for petroleum exploration

  7. Water isotope partitioning and ecohydrologic separation in mixed conifer forest explored with a centrifugation water extraction method

    Science.gov (United States)

    Bowers, W.; Mercer, J.; Pleasants, M.; Williams, D. G.

    2017-12-01

    Isotopic partitioning of water within soil into tightly and loosely bound fractions has been proposed to explain differences between isotopic water sources used by plants and those that contribute to streams and ground water, the basis for the "two water worlds" hypothesis. We examined the isotope ratio values of water in trees, bulk soil, mobile water collected from soil lysimeters, stream water, and GW at three different hillslopes in a mixed conifer forest in southeastern Wyoming, USA. Hillslopes differed in aspect and topographic position with corresponding differences in surface energy balance, snowmelt timing, and duration of soil moisture during the dry summer. The isotopic results support the partitioning of water within the soil; trees apparently used a different pool of water for transpiration than that recovered from soil lysimeters and the source was not resolved with the isotopic signature of the water that was extracted from bulk soil via cryogenic vacuum distillation. Separating and measuring the isotope ratios values in these pools would test the assumption that the tightly bound water within the soil has the same isotopic signature as the water transpired by the trees. We employed a centrifugation approach to separate water within the soil held at different tensions by applying stepwise increases in rotational velocity and pressures to the bulk soil samples. Effluent and the remaining water (cryogenically extracted) at each step were compared. We first applied the centrifugation method in a simple lab experiment using sandy loam soil and separate introductions of two isotopically distinct waters. We then applied the method to soil collected from the montane hillslopes. For the lab experiment, we predicted that effluents would have distinct isotopic signatures, with the last effluent and extracted water more closely representing the isotopic signature of the first water applied. For our field samples, we predicted that the isotopic signature of the

  8. Isotope methods in hydrology

    International Nuclear Information System (INIS)

    Moser, H.; Rauert, W.

    1980-01-01

    Of the investigation methods used in hydrology, tracer methods hold a special place as they are the only ones which give direct insight into the movement and distribution processes taking place in surface and ground waters. Besides the labelling of water with salts and dyes, as in the past, in recent years the use of isotopes in hydrology, in water research and use, in ground-water protection and in hydraulic engineering has increased. This by no means replaces proven methods of hydrological investigation but tends rather to complement and expand them through inter-disciplinary cooperation. The book offers a general introduction to the application of various isotope methods to specific hydrogeological and hydrological problems. The idea is to place the hydrogeologist and the hydrologist in the position to recognize which isotope method will help him solve his particular problem or indeed, make a solution possible at all. He should also be able to recognize what the prerequisites are and what work and expenditure the use of such methods involves. May the book contribute to promoting cooperation between hydrogeologists, hydrologists, hydraulic engineers and isotope specialists, and thus supplement proven methods of investigation in hydrological research and water utilization and protection wherever the use of isotope methods proves to be of advantage. (orig./HP) [de

  9. Method for separating isotopes

    International Nuclear Information System (INIS)

    Jepson, B.E.

    1975-01-01

    Isotopes are separated by contacting a feed solution containing the isotopes with a cyclic polyether wherein a complex of one isotope is formed with the cyclic polyether, the cyclic polyether complex is extracted from the feed solution, and the isotope is thereafter separated from the cyclic polyether

  10. Method for separating isotopes

    International Nuclear Information System (INIS)

    Schlenker, R.F.

    1978-01-01

    A vortex tube for separating isotopes is described. A gas mixture containing the isotopic molecules enters the vortex tube under pressure and is separated into a hot discharge flow stream and a cold discharge flow stream. The hot discharge is enriched in lighter isotopic molecules whereas the cold discharge flow stream is enriched in the heavier isotopic molecules. The vortex tube can be used in a single stage or multistage isotope separation apparatus

  11. Isotope separation method and apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.L.

    1980-01-01

    A method and apparatus are specified for separating a mixture of isotopes present in a compound, preferably a gaseous compound, into two or more parts in each of which the abundances of the isotopes differ from the natural abundances of the isotopes in the compound. The invention particularly relates to carrying out a laser induced, isotopically selective conversion of gaseous molecules in such a manner as to achieve more than one stage of isotope separation along the length of the laser beam. As an example, the invention is applied to the separation of the isotopes of uranium in UF 6 , in which either the U-235 or U-238 isotope is selectively excited by means of irradiation from an infrared laser, and the selectively excited isotope converted into a product that can be recovered from UF 6 by one of a variety of methods that are described. (U.K.)

  12. Method of isotope separation

    Energy Technology Data Exchange (ETDEWEB)

    Lyon, R K

    1975-05-22

    Isotopes of a gaseous compound can be separated by multi-infrared photoabsorption which follows a selective dissociation of the excited molecules by single photon absorption of photons of visible or UV radiation. The process involves three steps. Firstly, the molecules to be separated are irradiated with a high-energy IR laser, whereby the molecules of the compound containing the lighter isotopes are preferably excited. They are then irradiated by a second laser with UV or visible light whose frequency of radiation brings the excited molecules into a form in which they can be separated from the non-excited molecules. The third step is the reformation of the substances according to known methods. A power density of at least 10/sup 4/ watt/cm/sup 2/ per torr gas pressure with an irradiation time of 10/sup -10/ to 5 x 10/sup -5/ seconds in the presence of a second gas with at least 5 times higher partial pressure is necessary for the IR radiation. The method may be used for UF/sub 6/ for which an example is given here.

  13. Basic methods of isotope analysis

    International Nuclear Information System (INIS)

    Ochkin, A.V.; Rozenkevich, M.B.

    2000-01-01

    The bases of the most applied methods of the isotope analysis are briefly presented. The possibilities and analytical characteristics of the mass-spectrometric, spectral, radiochemical and special methods of the isotope analysis, including application of the magnetic resonance, chromatography and refractometry, are considered [ru

  14. ISOTOPE METHODS IN HOMOGENEOUS CATALYSIS.

    Energy Technology Data Exchange (ETDEWEB)

    BULLOCK,R.M.; BENDER,B.R.

    2000-12-01

    The use of isotope labels has had a fundamentally important role in the determination of mechanisms of homogeneously catalyzed reactions. Mechanistic data is valuable since it can assist in the design and rational improvement of homogeneous catalysts. There are several ways to use isotopes in mechanistic chemistry. Isotopes can be introduced into controlled experiments and followed where they go or don't go; in this way, Libby, Calvin, Taube and others used isotopes to elucidate mechanistic pathways for very different, yet important chemistries. Another important isotope method is the study of kinetic isotope effects (KIEs) and equilibrium isotope effect (EIEs). Here the mere observation of where a label winds up is no longer enough - what matters is how much slower (or faster) a labeled molecule reacts than the unlabeled material. The most careti studies essentially involve the measurement of isotope fractionation between a reference ground state and the transition state. Thus kinetic isotope effects provide unique data unavailable from other methods, since information about the transition state of a reaction is obtained. Because getting an experimental glimpse of transition states is really tantamount to understanding catalysis, kinetic isotope effects are very powerful.

  15. Method for separating krypton isotopes

    International Nuclear Information System (INIS)

    Porter, J.T.

    1980-01-01

    Methods and apparatus for separating krypton isotopes utilizing low temperature selective infrared excitation of 85krypton difluoride in an isotopic compound mixture. Multiphoton ir excitation and uv excitation techniques are used, as well as cryogenic matrix isolation and inert buffer gas isolation techniques

  16. Method to separate isotopes

    International Nuclear Information System (INIS)

    Coenen, H.; Neuschuetz, D.

    1980-01-01

    An extraction by means of supercritical pure gases (e.g. CD 2 ) or gas mixtures is proposed to separate isotopes, especially H/D, Li-6/Li-7, and U-235/U-238, and water or benzol is used as entrainer. The extraction shall be carried out at pressure rates of about 350 bar above the critical pressure with the temperature being by up to 100 0 C above the critical temperature. A NaCl-solution and the change of the isotopic ratio Cl-35/Cl-37 are investigated for example purpose. (UWI) [de

  17. Isotope separation apparatus and method

    International Nuclear Information System (INIS)

    Feldman, B. J.

    1985-01-01

    The invention relates to an improved method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferably substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. Because the molecules in the beam occupy various degenerate energy levels, if the laser beam comprises chirped pulses comprising selected wavelengths, the laser beam will very efficiently excite substantially all unexcited molecules and will cause stimulated emission of substantially all excited molecules of a selected one of the isotopes in the beam which such pulses encounter. Excitation caused by first direction chirped pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning chirped pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement of essentially all the molecules containing the one isotope is accomplished by a large number of chirped pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam

  18. Isotope hydrogeochemistry in exploration for buried and blind mineralization

    International Nuclear Information System (INIS)

    Andrew, A.S.; Carr, G.R.; Giblin, A.M.; Whitford, D.J.

    2000-01-01

    Buried and blind deposits, with no direct geological or geochemical manifestation at the surface, are becoming increasingly important targets in Australia. One of the key exploration challenges relates to assessing and ranking targets established from geophysical and other remotely sensed surveys. Sub-surface geology is reflected in the geochemistry of groundwaters (Giblin, 1996) and hydrogeochemical methods provide a particularly powerful technique in areas of poor surface exposure, deep weathering and where transported overburden obscures the underlying geology (Giblin, 1997). In such areas several hundred samples are used to define locally prospective areas although how these relate to a specific mineralization style may be difficult to determine. The question of proximity to an orebody is fundamental to mineral exploration and isotopic (S, Pb, Sr) methods are uniquely capable of contributing to an answer. The isotopic composition of ores and waters that interact with ores carries important information about the elemental source; S and Pb are direct ore indicators allowing straight-forward interpretation of possible ore associations. The isotopic methods also provide unequivocal evidence for mixing. The isotopic compositions of S, Pb and Sr in rocks are unaffected by weathering and in natural waters are unaffected by precipitation, evaporation or dilution. Isotopic methods provide information that is complementary to that obtainable from major and trace element abundances. The application of integrated isotopic studies to conventional hydrogeochemical interpretations was tested in several areas (Fig. 1); Menninnie Dam (Pb, Zn; Eyre Peninsula SA), Abra (Ag, Pb; Bangemall Basin WA), Benambra (Cu, Zn, Pb: Lachlan Fold Belt Vic), Goonumbla (Cu, Au; Lachlan Fold Belt NSW) and Kanmantoo (Cu, Pb, Zn, Au; Kanmantoo Fold Belt SA). These were chosen to include different deposit types, tectonic regimes, climatic and topographic environments and groundwater chemistry

  19. Isotope separation apparatus and method

    International Nuclear Information System (INIS)

    Cotter, T.P.

    1982-01-01

    The invention relates to a method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferable substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. The laser beam comprises pi-pulses of a selected wavelength which excite unexcited molecules, or cause stimulated emission of excited molecules of one of the isotopes. Excitation caused by first direction pi-pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning pi-pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement is accomplished by a large number of pi-pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam

  20. Method and device for isotope separation

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1976-01-01

    The method works with a converted Q machine. The plasma containing the isotopes to be separated is crossed by a magnetic field running in the direction of the plasma column. More energy is transfered to the chosen isotope by oscillating magnetic and/or electric fields or by sound waves by using the specific resonance frequency for the selected isotope. The isotopes thus heated to different extents can be separated according to various methods given in the patent claims. (GG) [de

  1. Isotope separations using chromatographic methods

    International Nuclear Information System (INIS)

    Leseticky, L.

    1985-01-01

    A survey is given of chromatographic separations of compounds only differing in isotope composition. Isotope effects on physical properties which allow chromatographic separation (vapour tension, adsorption heat, partition coefficient) are very small, with the exception of the simplest molecules. Therefore, separation factors only assume the value of several per cent. From this ensues the necessity of using columns which are specially and very carefully prepared and have a separation efficiency of the order of 10 4 theoretical plates. Briefly discussed is liquid chromatography on ion exchangers which with a varied degree of success was used for separating simple inorganic compounds or ions. Ion exchange chromatography of amino acids labelled with tritium, and chromatography of tritium labelled steroids also provided only a certain degree of separation. A detailed analysis is presented of gas chromatography separation of various deuterium and tritium labelled low-molecular compounds, to which a number of studies has been devoted in the literature. Very promising is the method of complexation gas chromatography based on the reversible formation of a complex of the ligand (the compound being separated) and the compound of the (transition) metal as the steady-state phase. (author)

  2. Method for separating gaseous mixtures of isotopes

    International Nuclear Information System (INIS)

    Neimann, H.J.; Schuster, E.; Kersting, A.

    1976-01-01

    A gaseous mixture of isotopes is separated by laser excitation of the isotope mixture with a narrow band of wavelengths, molecularly exciting mainly the isotope to be separated and thereby promoting its reaction with its chemical partner which is excited in a separate chamber. The excited isotopes and the chemical partner are mixed, perhaps in a reaction chamber to which the two excited components are conducted by very short conduits. The improvement of this method is the physical separation of the isotope mixture and its partner during excitation. The reaction between HCl and the mixture of 238 UF 6 and 235 UF 6 is discussed

  3. Exploring Monte Carlo methods

    CERN Document Server

    Dunn, William L

    2012-01-01

    Exploring Monte Carlo Methods is a basic text that describes the numerical methods that have come to be known as "Monte Carlo." The book treats the subject generically through the first eight chapters and, thus, should be of use to anyone who wants to learn to use Monte Carlo. The next two chapters focus on applications in nuclear engineering, which are illustrative of uses in other fields. Five appendices are included, which provide useful information on probability distributions, general-purpose Monte Carlo codes for radiation transport, and other matters. The famous "Buffon's needle proble

  4. Method for isotope separation by photodeflection

    International Nuclear Information System (INIS)

    Bernhardt, A.F.

    1977-01-01

    In the method of separating isotopes wherein a desired isotope species is selectively deflected out of a beam of mixed isotopes by irradiating the beam with a directed beam of light of narrowly defined frequency which is selectively absorbed by the desired species, the improvement comprising irradiating the deflected beam with light from other light sources whose frequencies are selected to cause the depopulation of any metastable excited states

  5. A method of uranium isotopes concentration analysis

    International Nuclear Information System (INIS)

    Lin Yuangen; Jiang Meng; Wu Changli; Duan Zhanyuan; Guo Chunying

    2010-01-01

    A basic method of uranium isotopes concentration is described in this paper. The iteration method is used to calculate the relative efficiency curve, by analyzing the characteristic γ energy spectrum of 235 U, 232 U and the daughter nuclide of 238 U, then the relative activity can be calculated, at last the uranium isotopes concentration can be worked out, and the result is validated by the experimentation. (authors)

  6. Isotope angiocardiography. Method and preliminary own studies

    Energy Technology Data Exchange (ETDEWEB)

    Stepinska, J; Ruzyllo, W; Konieczny, W [Centrum Medyczne Ksztalcenia Podyplomowego, Warsaw (Poland)

    1979-01-01

    Method of technetium isotope 99 m pass through the heart recording with the aid of radioisotope scanner connected with seriograph and computer is being presented. Preliminary tests were carried out in 26 patients with coronary disease without or with previous myocardial infarction, cardiomyopathy, ventricular septal defect and in patients with artificial mitral and aortic valves. The obtained scans were evaluated qualitatively and compared with performed later contrast X-rays of the heart. Size of the right ventricle, volume and rate of left atrial evacuation, size and contractability of left ventricle were evaluated. Similarity of direct and isotope angiocardiographs, non-invasional character and repeatability of isotope angiocardiography advocate its usefulness.

  7. Geophysical Exploration. New site exploration method

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Tsuneo; Otomo, Hideo; Sakayama, Toshihiko

    1988-07-25

    Geophysical exploration is used for geologic survey to serve purposes in civil engineering. New methods are being developed inside and outside Japan and are used to serve various purposes. This paper discusses recently developed techniques based on the measurement of seismic waves and electric potential. It also explains seismic tomography, radar tomography, and resistivity tomography which are included in the category of geotomography. At present, effort is being made to apply geophysical exploration technology to problems which were considered to be unsuitable for conventional exploration techniques. When such effort proceeds successfully, it is necessary to develop technology for presenting results quickly and exploration equipment which can work in various conditions. (10 figs, 15 refs)

  8. Exploration of inner mammary chains by isotopic lymphography

    International Nuclear Information System (INIS)

    Arnaud, D.; Basse-Cathalinat, B.; Blanquet, P.; Dilhuydy, J.M.; Ducassou, D.

    1978-01-01

    The indirect isotopic lymphography of the internal mammary lymph nodes, is an interesting method of investigations as it is the only one which allows the visualization of these nodes, quite difficult to explore. The radioactive molecule used for this study is an antimony sulfocolloid labelled by technetium-99m. This material seems to be the most suitable more for its physical than physiological properties; it is injected into the posterium wall of the rectus muscle on both sides of the medium line. The main parameters obtained from this study on 30 normal and 20 pathological patients give morphological data: number of nodes, their position within intercostal spaces, the width of both chains, their aspect, the presence of subclavicular nodes, or the intercatenar spontaneous passage. On the other hand, the semeiologic data are much more difficult to individualize because of the very great variability of those nodes. Some special shapes give us no doubt as to the spreading of the nodes; but most of the time, just a modification of the scintigram aspect at the time assures us of the extension of neoplasm. This method, almost non invasive for the patient, and for which no local reaction of intolerance has been found, allows the radiotherapist to define its scope of irradiation on each patient, instead of referring himself to literature data, which are only average values [fr

  9. Method of eliminating gaseous hydrogen isotopes

    International Nuclear Information System (INIS)

    Nagakura, Masaaki; Imaizumi, Hideki; Suemori, Nobuo; Aizawa, Takashi; Naito, Taisei.

    1983-01-01

    Purpose: To prevent external diffusion of gaseous hydrogen isotopes such as tritium or the like upon occurrence of tritium leakage accident in a thermonuclear reactor by recovering to eliminate the isotopes rapidly and with safety. Method: Gases at the region of a reactor container where hydrogen isotopes might leak are sucked by a recycing pump, dehumidified in a dehumidifier and then recycled from a preheater through a catalytic oxidation reactor to a water absorption tower. In this structure, the dehumidifier is disposed at the upstream of the catalytic oxidation reactor to reduce the water content of the gases to be processed, whereby the eliminating efficiency for the gases to be processed can be maintained well even when the oxidation reactor is operated at a low temperature condition near the ambient temperature. This method is based on the fact that the oxidating reactivity of the catalyst can be improved significantly by eliminating the water content in the gases to be processed. (Yoshino, Y.)

  10. Hydrogen isotope separation by cryogenic distillation method

    International Nuclear Information System (INIS)

    Hayakawa, Nobuo; Mitsui, Jin

    1987-01-01

    Hydrogen isotope separation in fusion fuel cycle and tritium recovery from heavy water reactor are very important, and therefore the early establishment of these separation techniques are desired. The cryogenic distillation method in particular is promising for the separation of hydrogen isotope and the recovery of high concentrated tritium. The studies of hydrogen isotope separation by cryogenic distillation method have been carried out by using the experimental apparatus made for the first time in Japan. The separation of three components (H 2 -HD-D 2 ) under total reflux conditions was got by using the packing tower of 500 mm height. It was confirmed that the Height Equivalent Theoretical Plate (HETP) was 20 - 30 mm for the vapor's line velocity of 20 - 80 mm/s. (author)

  11. Assessing wine quality using isotopic methods

    International Nuclear Information System (INIS)

    Costinel, Diana; Ionete, Roxana Elena; Vremera, Raluca; Stefanescu, Ioan

    2010-01-01

    Full text: The analytical methods used to determine the isotope ratios of deuterium, carbon-13 and oxygen-18 in wines have gained official recognition from the Office International de la Vigne et du Vin (OIV) and National Organisation of Vine and Wine. The amount of stable isotopes in water and carbon dioxide from plant organic materials and their distribution in sugar and ethanol molecules are influenced by geo-climatic conditions of the region, grape varieties and the year of harvest. For wine characterization, to prove the botanical and geographical origin of the raw material, the isotopic analysis by continuous flow mass spectrometry CF-IRMS has made a significant contribution. This paper emphasize the results of a study concerning the assessing of water adulterated wines and non-grape alcohol and sugar additions at different concentration levels, using CF-IRMS analytical technique. (authors)

  12. Isotopic ratio method for determining uranium contamination

    International Nuclear Information System (INIS)

    Miles, R.E.; Sieben, A.K.

    1994-01-01

    The presence of high concentrations of uranium in the subsurface can be attributed either to contamination from uranium processing activities or to naturally occurring uranium. A mathematical method has been employed to evaluate the isotope ratios from subsurface soils at the Rocky Flats Nuclear Weapons Plant (RFP) and demonstrates conclusively that the soil contains uranium from a natural source and has not been contaminated with enriched uranium resulting from RFP releases. This paper describes the method used in this determination which has widespread application in site characterizations and can be adapted to other radioisotopes used in manufacturing industries. The determination of radioisotope source can lead to a reduction of the remediation effort

  13. Age, genesis and exploration for mineral deposits: the possibilities offered by lead isotopes

    International Nuclear Information System (INIS)

    Marcoux, E.; Calvez, J.Y.

    1985-01-01

    After a brief theoretical survey of the subject, the paper discusses the assistance that lead isotopes can bring to solving problems of metallogenesis and mineral exploration. Lead isotopes act as a true geologic clock when radioactive decay of lead takes place in a closed U-Th-Pb system, or when these conditions have been recreated by homogenization of a large crustal segment. The lead clock is thus reliable for deposits whose process of formation was part of a hydrothermal event that affected a significant part of the crust, most importantly in island-arc volcanosedimentary deposits, much less so for deposits formed by spatially restricted hydrothermal activity such as the emplacement of veins. Very interesting possibilities are also to be found in the capacity of lead isotopes to act as geochemical tracers. In conjunction with paragenetic and gitologic studies, determination of the isotopic composition of lead allows the sources of metals to be identified and permits an approach to the understanding of inheritance phenomena in a mineral deposit or province. This information also assists in unravelling the successive metallogenic processes in a region, thus contributing to refinement of the concept of a metallogenic province. Lastly lead isotopes provide an additional factor in assessing the economic potential of a deposit undergoing exploration. The method is based on a comparison of the isotopic signature of the deposit with that of economic mineralization occuring elsewhere in the circa. Examples of stratiform deposits and the gold-bearing veins of Limousin are described. The application of this method to gossans can provide additional information to standard geochemistry and thus assist in grading of targets [fr

  14. Isotope separation in plasma by ion-cyclotron resonance method

    International Nuclear Information System (INIS)

    Dubinov, A.E.; Kornilova, I.Yu.; Selemir, V.D.

    2001-01-01

    Contemporary state of investigation on isotope separation in plasma using selective ion-cyclotron resonance (ICR) heating is considered. The main attention is paid to necessary conditions of heating selectivity, plasma creation methods in isotope ICR-separation facilities, selection of antenna systems for heating, and principles of more-heated component selection. Experimental results obtained at different isotope mixtures separation are presented [ru

  15. Separation of the mercury isotopes by the indirect photochemical method

    International Nuclear Information System (INIS)

    Botter nee Bergheaud, F.; Scaringella nee Desnoyer, M.; Wacongne, M.

    1976-01-01

    A method of photochemical separation of the mercury isotopes by the so-called indirect route in which a gas stream of oxygen and butadiene containing a mixture of mercury isotopes is passed through one or a number of vessels placed in series. The gas stream is irradiated by a lamp containing mercury which is depleted in one or a number of the isotopes and said isotopes are recovered in a trap placed downstream of the vessel or vessels

  16. Method for the enrichment of isotopes

    International Nuclear Information System (INIS)

    Schuster, E.; Kersting, A.; Gebauhr, W.

    1976-01-01

    A method for the enrichment of isotopes, especially of uranium compounds, is described, working according to the principle of selective excitation by laser beams. As the starting compound, UF 6 is mentioned; the reaction partness are atomic gases (hydrogen, oxygen, nitrogen) or radicals (CH 3 , CHO). According to the invention, the gas mixture flows through the reaction space with a velocity so large that in leaving it, recombination of the reaction partner will already take place again. In this way, competing thermal reactions will be avoided and energy transfer fo excited 235 U molecules to non-excited 238 U molecules is eliminated to a large extent. A suitable equipment for implementing the method is described. (UWI) [de

  17. Method of deuterium isotope separation and enrichment

    International Nuclear Information System (INIS)

    Benson, S.W.

    1980-01-01

    A method of deuterium isotope separation and enrichment using infrared laser technology in combination with chemical processes for treating and recycling the unreacted and deuterium-depleted starting materials is described. Organic molecules of the formula RX (where R is an ethyl, isopropyl, t-butyl, or cyclopentenyl group and X is F, Cl, Br or OH) containing a normal abundance of hydrogen and deuterium are exposed to intense laser infrared radiation. An olefin containing deuterium (olefin D) will be formed, along with HX. The enriched olefin D can be stripped from the depleted stream of RX and HX, and can be burned to form enriched water or pyrolyzed to produce hydrogen gas with elevated deuterium content. The depleted RX is decomposed to olefins and RX, catalytically exchanged with normal water to restore the deuterium content to natural levels, and recombined to form RX which can be recycled. (LL)

  18. Exploring the isotopic niche: isotopic variance, physiological incorporation, and the temporal dynamics of foraging

    Directory of Open Access Journals (Sweden)

    Justin Douglas Yeakel

    2016-01-01

    Full Text Available Consumer foraging behaviors are dynamic, changing in response to prey availability, seasonality, competition, and even the consumer's physiological state. The isotopic composition of a consumer is a product of these factors as well as the isotopic `landscape' of its prey, i.e. the isotopic mixing space. Stable isotope mixing models are used to back-calculate the most likely proportional contribution of a set of prey to a consumer's diet based on their respective isotopic distributions, however they are disconnected from ecological process. Here we build a mechanistic framework that links the ecological and physiological processes of an individual consumer to the isotopic distribution that describes its diet, and ultimately to the isotopic composition of its own tissues, defined as its `isotopic niche’. By coupling these processes, we systematically investigate under what conditions the isotopic niche of a consumer changes as a function of both the geometric properties of its mixing space and foraging strategies that may be static or dynamic over time. Results of our derivations reveal general insight into the conditions impacting isotopic niche width as a function of consumer specialization on prey, as well as the consumer's ability to transition between diets over time. We show analytically that moderate specialization on isotopically unique prey can serve to maximize a consumer's isotopic niche width, while temporally dynamic diets will tend to result in peak isotopic variance during dietary transitions. We demonstrate the relevance of our theoretical findings by examining a marine system composed of nine invertebrate species commonly consumed by sea otters. In general, our analytical framework highlights the complex interplay of mixing space geometry and consumer dietary behavior in driving expansion and contraction of the isotopic niche. Because this approach is established on ecological mechanism, it is well-suited for enhancing the

  19. ATTA - A new method of ultrasensitive isotope trace analysis

    International Nuclear Information System (INIS)

    Bailey, K.; Chen, C.Y.; Du, X.; Li, Y.M.; Lu, Z.-T.; O'Connor, T.P.; Young, L.

    2000-01-01

    A new method of ultrasensitive isotope trace analysis has been developed. This method, based on the technique of laser manipulation of neutral atoms, has been used to count individual 85 Kr and 81 Kr atoms present in a natural krypton gas sample with isotopic abundances in the range of 10 -11 and 10 -13 , respectively. This method is free of contamination from other isotopes and elements and can be applied to various different isotope tracers for a wide range of applications. The demonstrated detection efficiency is 1x10 -7 . System improvements could increase the efficiency by many orders of magnitude

  20. Method and apparatus for separating uranium isotopes

    International Nuclear Information System (INIS)

    Bernstein, E.R.

    1977-01-01

    A uranium compound in the solid phase (uranium borohydride four) is subjected to radiation of a first predetermined frequency that excites the uranium-235 isotope-bearing molecules but not the uranium-238 isotope-bearing molecules. The compound is simultaneously subjected to radiation of a second predetermined frequency which causes the excited uranium-235 isotope-bearing molecules to chemically decompose but which does not affect the uranium-238 isotope-bearing molecules. Sufficient heat is then applied to the irradiated compound in the solid phase to vaporize the non-decomposed uranium-238 isotope-bearing molecules but not the decomposed uranium-235 isotope-bearing molecules, thereby physically separating the uranium-235 isotope-bearing molecules from the uranium-238 isotope-bearing molecules. The uranium compound sample in the solid phase is deposited or grown in an elongated tube supported within a dewar vessel having a clear optical path tail section surrounded by a coolant. Two sources of radiation are focused on the uranium compound sample. A heating element is attached to the elongated tube to vaporize the irradiated compound

  1. Gas isotope separation method using plasma sheet

    International Nuclear Information System (INIS)

    Takayama, K.; Takagi, K.; Fukvi, R.

    1988-03-01

    A high frequency electric field is applied to a plasma sheet with a frequency equal to the cyclotronic frequency of the ions to be separated. Because of resonance the cyclotronic radius of the isotope has increased and the electric charge is eliminated by collision with a separator and the isotope is separated in neutral particles [fr

  2. Method of isotope separation by chemi-ionization

    International Nuclear Information System (INIS)

    Wexler, S.; Young, C.E.

    1977-01-01

    A method is disclosed for separating isotopes in an isotopic mixture by aerodynamically accelerating a gaseous compound to form a jet of molecules, and passing the jet through a stream of electron donor atoms whereby an electron transfer takes place, thus forming negative ions of the molecules. The molecular ions are then passed through a radiofrequency quadrupole mass filter to separate the specific isotopes. cThis method may be used for any compounds having a sufficiently high electron affinity to permit negative ion formation, and is especially useful for the separation of plutonium and uranium isotopes. 10 claims, 1 figure

  3. Basic methods of isotope analysis; Osnovnye metody analiza izotopov

    Energy Technology Data Exchange (ETDEWEB)

    Ochkin, A V; Rozenkevich, M B

    2000-07-01

    The bases of the most applied methods of the isotope analysis are briefly presented. The possibilities and analytical characteristics of the mass-spectrometric, spectral, radiochemical and special methods of the isotope analysis, including application of the magnetic resonance, chromatography and refractometry, are considered.

  4. Method and apparatus for isotope separation from a gas stream

    International Nuclear Information System (INIS)

    Szoke, A.

    1978-01-01

    A method and apparatus are described for isotope separation and in particular for separating the desired isotope from the gas in which it is contained by irradiating it with a laser. The laser selectively provides kinetic energy to the isotope through inelastic events, monomolecular or bimolecular, in order to cause it to segregate within or fly out of the gas stream in which it is contained

  5. Method and apparatus for separating isotopes

    International Nuclear Information System (INIS)

    Harris, S.E.

    1976-01-01

    Isotope separation is achieved between species A and B having an absorption resonance separated by an isotopic shift by selectively exciting a portion of species A using a tunable photon source of narrow emission line with and subsequently causing collisions with an optically excited third species to selectively ionize the excited portion of species A. When ionized, species A is easily separated by any technique, using its ionized condition to distinguish it from species B. 18 claims, 3 drawing figures

  6. Method and device for the enrichment of isotopes

    International Nuclear Information System (INIS)

    Stehle, H.

    1976-01-01

    A variation of a method for isotope enrichment by laser radiation is proposed which improves the selectivity and with it the economy of the method by eliminating undesired reactions caused by thermal activation. The method according to the invention is applied discontinuously in three steps: The isotope mixture and the reacting agents are fed to a vessel, a laser beam is passed through, and the contents are emptied into a vacuum tank while expanding adiabatically. The time steps are controlled. The method is explained using the example of separating an isotope mixture of UF 6 . (UWI) [de

  7. Exploring Neutron-Rich Oxygen Isotopes with MoNA

    International Nuclear Information System (INIS)

    Frank, N.; Gade, A.; Peters, W. A.; Thoennessen, M.; Baumann, T.; Bazin, D.; Lecouey, J.-L.; Scheit, H.; Schiller, A.; Brown, J.; DeYoung, P. A.; Finck, J. E.; Hinnefeld, J.; Howes, R.; Luther, B.

    2007-01-01

    The Modular Neutron Array (MoNA) was used in conjunction with a large-gap dipole magnet (Sweeper) to measure neutron-unbound states in oxygen isotopes close to the neutron dripline. While no excited states were observed in 24 O, a resonance at 45(2) keV above the neutron separation energy was observed in 23 O

  8. Discriminating background from anthropogenic lead by isotopic methods

    International Nuclear Information System (INIS)

    Nelson, B.K.; O'Brien, H.E.

    1995-01-01

    The goal of this pilot project was to evaluate the practicality of using natural variations in the isotopic composition of lead to test for the presence of anthropogenic lead in soil, surface water and ground water. Complex chemical reactions in the environment may cause measured lead concentrations to be ambiguous indicators of anthropogenic lead component. The lead isotope tracer technique has the potential to identify both the presence and proportion of anthropogenic lead in the environment. The tested the lead isotope technique at Eielson Air Force Base, Alaska, on sources of suspected fuel contamination. Although the results are specific to this base, the general technique of using lead isotopes to trace the movement of anthropogenic lead is applicable to other CERCLA sites. The study had four objectives: (1) characterize the natural lead isotope composition of bedrock, stream sediment and soils; (2) characterize the isotopic composition of the contaminant lead derived from fuel; (3) evaluate the sensitivity of the isotopic method to distinguishing between anthropogenic and natural lead in soil and water samples and (4) evaluate the analytical feasibility and accuracy of the method at the Isotope Geochemistry Laboratory at the University of Washington

  9. Methods for removing radioactive isotopes from contaminated streams

    International Nuclear Information System (INIS)

    Hoy, D.R.; Hickey, T.N.; Spulgis, I.S.; Parish, H.C.

    1979-01-01

    Methods for removing radioactive isotopes from contaminated gas streams for use in atmospheric containment and cleanup systems in nuclear power plants are provided. The methods provide for removal of radioactive isotopes from a first portion of the contaminated stream, separated from the remaining portion of the stream, so that adsorbent used to purify the first portion of the contaminated stream by adsorption of the radioactive isotopes therefrom can be tested to determine the adsorbing efficacy of the generally larger portion of adsorbent used to purify the remaining portion of the stream

  10. New Isotope Analysis Method: Atom Trap Mass Spectrometry

    International Nuclear Information System (INIS)

    Ko, Kwang Hoon; Park, Hyun Min; Han, Jae Min; Kim, Taek Soo; Cha, Yong Ho; Lim, Gwon; Jeong, Do Young

    2011-01-01

    Trace isotope analysis has been an important role in science, archaeological dating, geology, biology and nuclear industry. Some fission products such as Sr-90, Cs-135 and Kr-85 can be released to the environment when nuclear accident occurs and the reprocessing factory operates. Thus, the analysis of artificially produced radioactive isotopes has been of interest in nuclear industry. But it is difficult to detect them due to low natural abundance less then 10 -10 . In general, radio-chemical method has been applied to detect ultra-trace radio isotopes. But this method has disadvantages of long measurement time for long lived radioisotopes and toxic chemical process for the purification. The Accelerator Mass Spectrometer has high isotope selectivity, but the system is huge and its selectivity is affected by isobars. The laser based method, such as RIMS (Resonance Ionization Mass Spectrometry) has the advantage of isobar-effect free characteristics. But the system size is still huge for high isotope selective system. Recently, ATTA (Atom Trap Trace Analysis) has been successfully applied to detect ultra-trace isotope, Kr-81 and Kr-85. ATTA is the isobar-effect free detection with high isotope selectivity and the system size is small. However, it requires steady atomic beam source during detection, and is not allowed simultaneous detection of several isotopes. In this presentation, we introduce new isotope detection method which is a coupled method of Atom Trap Mass Spectrometry (ATMS). We expect that it can overcome the disadvantage of ATTA while it has both advantages of ATTA and mass spectrometer. The basic concept and the system design will be presented. In addition, the experimental status of ATMS will also be presented

  11. Explorative methods in linear models

    DEFF Research Database (Denmark)

    Høskuldsson, Agnar

    2004-01-01

    The author has developed the H-method of mathematical modeling that builds up the model by parts, where each part is optimized with respect to prediction. Besides providing with better predictions than traditional methods, these methods provide with graphic procedures for analyzing different feat...... features in data. These graphic methods extend the well-known methods and results of Principal Component Analysis to any linear model. Here the graphic procedures are applied to linear regression and Ridge Regression....

  12. Method for separation and enrichment of isotopes

    International Nuclear Information System (INIS)

    Kakihana, H.; Miyamatsu, T.

    1977-01-01

    Boron or uranium isotopes can be chemically separated and enriched with high speed and with high separating efficiency by using weakly basic anion exchange fibers having a diameter of not more than 100 μ, an aspect ratio of at least 5 and an exchange capacity of at least 2 meq/g-dry fiber, which are packed in a column at a specific volume of 2.0 to 20.0 ml/g-dry fiber

  13. An isotope method for the measurement of creaming

    International Nuclear Information System (INIS)

    Wiechen, A.; Heine, K.

    1974-01-01

    The principle of a method is described which allows the course of creaming to be recorded continously and automatically by means of isotopes. Without affecting the colloidal system of milk, an isotope is added in hydrosoluble form and with only small amounts of carriers. A small detector sensitive to the respective radiation of the isotope is used to measure the decrease of counting rate on the head of the creaming cylinder, the decrease of rate being due to the effective recess of the radiation source and to the absorption of rays in the cream layer. The choice of the isotope, i.e. kind and energy of its radiation, and of the detector allows to adapt the sensitivity of the method to the rate of creaming. The method described appears to be superior to those techniques in which sedimentation balances are used; it could therefore supply useful information in research work on the process of creaming. (orig.) [de

  14. Low energy methods of molecular laser isotope separation

    International Nuclear Information System (INIS)

    Makarov, G N

    2015-01-01

    Of the many proposals to date for laser-assisted isotope separation methods, isotope-selective infrared (IR) multiphoton dissociation (MPD) of molecules has been the most fully developed. This concept served as the basis for the development and operation of the carbon isotope separation facility in Kaliningrad, Russia. The extension of this method to heavy elements, including uranium, is hindered by, among other factors, the high power consumption and the lack of high-efficiency high-power laser systems. In this connection, research and development covering low energy methods for the laser separation of isotopes (including those of heavy atoms) is currently in high demand. This paper reviews approaches to the realization of IR-laser-induced isotope-selective processes, some of which are potentially the basis on which low-energy methods for molecular laser isotope separation can be developed. The basic physics and chemistry, application potential, and strengths and weaknesses of these approaches are discussed. Potentially promising alternatives to the title methods are examined. (reviews of topical problems)

  15. Isotope decay equations solved by means of a recursive method

    International Nuclear Information System (INIS)

    Grant, Carlos

    2009-01-01

    The isotope decay equations have been solved using forward finite differences taking small time steps, among other methods. This is the case of the cell code WIMS, where it is assumed that concentrations of all fissionable isotopes remain constant during the integration interval among other simplifications. Even when the problem could be solved running through a logical tree, all algorithms used for resolution of these equations used an iterative programming formulation. That happened because nearly all computer languages used up to a recent past by the scientific programmers did not support recursion, such as the case of the old versions of FORTRAN or BASIC. Nowadays also an integral form of the depletion equations is used in Monte Carlo simulation. In this paper we propose another programming solution using a recursive algorithm, running through all descendants of each isotope and adding their contributions to all isotopes in each generation. The only assumption made for this solution is that fluxes remain constant during the whole time step. Recursive process is interrupted when a stable isotope was attained or the calculated contributions are smaller than a given precision. These algorithms can be solved by means an exact analytic method that can have some problems when circular loops appear for isotopes with alpha decay, and a more general polynomial method. Both methods are shown. (author)

  16. [Progress in stable isotope labeled quantitative proteomics methods].

    Science.gov (United States)

    Zhou, Yuan; Shan, Yichu; Zhang, Lihua; Zhang, Yukui

    2013-06-01

    Quantitative proteomics is an important research field in post-genomics era. There are two strategies for proteome quantification: label-free methods and stable isotope labeling methods which have become the most important strategy for quantitative proteomics at present. In the past few years, a number of quantitative methods have been developed, which support the fast development in biology research. In this work, we discuss the progress in the stable isotope labeling methods for quantitative proteomics including relative and absolute quantitative proteomics, and then give our opinions on the outlook of proteome quantification methods.

  17. Energy expenditures of plasma method of isotope separation

    International Nuclear Information System (INIS)

    Karchevskij, A.I.; Potanin, E.P.

    1986-01-01

    The estimations are performed of specific energy expenditares in isotope separation of binary mixtures in different plasma systems with weak medium ionization (plasma centrifuge, gas discharge system with travelling magnetic field, direct current discharge). Potential advantages of plasma centrifuge over other gas discharge facilities are pointed out. The comparison of specific energy expenditure values in case of using plasma and conventional methods of isotope separation is carried out

  18. Method and apparatus for controlled condensation isotope separation

    International Nuclear Information System (INIS)

    Sullivan, J.A.; Lee, J.T. Jr.; Kim, K.C.

    1981-01-01

    The invention provides a method for producing controlled homogeneous condensation of a molecular feed gas containing several isotopes. The feed gas flows at supersonic rates through an expansion nozzle under conditions at which the gas would normally condense. The gas is irradiated with laser radiation of a wavelength that selectively excites those molecules in the feed gas that contain a particular isotope, thus preventing their condensation. Condensate particles may be aerodynamically separated from the flowing gas stream

  19. Developing isotope techniques for water exploration in the Sahel

    International Nuclear Information System (INIS)

    Aranyossy, J.F.; Louvat, D.; Maksoudi, M.

    1991-01-01

    The IAEA in the early 1980s started its first activities on hydrogeology in Mali, Niger, and Senegal through its technical co-operation programme. These activities included, first of all, local aquifer studies with environmental isotopes. The studies were found to be particularly useful for obtaining specific information on, for example, relationships between aquifers and between surface water and groundwater, and the existence or absence of recent recharge. Moreover, the IAEA established the basic infrastructures needed for the application of artificial tracer techniques and the use of nuclear instrumentation in hydrology and hydrosedimentology. Several factors underscored the need for co-ordinating the scientific activities already being carried out under existing bilateral projects. Firstly, the ''horizontal'' flow of information was very poor in spite of the similarity between the hydrological and hydrogeological problems encountered in the three countries. Secondly, political frontiers do not generally follow the boundaries of the hydrological basins, so that the same aquifer can be shared between several countries. Thirdly, the costly infrastructure established by the IAEA in certain countries deserved to be utilized at the regional level. To meet these concerns, an African regional project was launched 4 years ago on the development of isotope and nuclear techniques in hydrology in the Sahelian countries. Its main objectives were to further broaden ongoing studies in the participating countries; to strengthen training; to promote exchange of information on various previous studies; to foster co-operation between the different institutes involved in these studies; and to reinforce the infrastructures established by the IAEA and their utilization in the region

  20. Chemometrical exploration of an isotopic ratio data set of acetylsalicylic acid

    International Nuclear Information System (INIS)

    Stanimirova, I.; Daszykowski, M.; Van Gyseghem, E.; Bensaid, F.F.; Lees, M.; Smeyers-Verbeke, J.; Massart, D.L.; Vander Heyden, Y.

    2005-01-01

    A data set consisting of fourteen isotopic ratios or quantities derived from such ratios for samples of acetylsalicylic acid (aspirin), commercialized by various pharmaceutical companies from different countries, was analyzed. The goal of the data analysis was to explore whether results can be linked to geographical origin or other features such as different manufacturing processes, of the samples. The methods of data analysis used were principal component analysis (PCA), robust principal component analysis (RPCA), projection pursuit (PP) and multiple factor analysis (MFA). The results do not seem to depend on geographic origin, except for some samples from India. They do depend on the pharmaceutical companies. Moreover, it seems that the samples from certain pharmaceutical companies form clusters of similar samples, suggesting that there is some common feature between those pharmaceutical companies. Variable selection performed by means of MFA showed that the number of variables can be reduced to five without loss of information

  1. Chemometrical exploration of an isotopic ratio data set of acetylsalicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Stanimirova, I. [ChemoAC, FABI, Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Daszykowski, M. [ChemoAC, FABI, Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Van Gyseghem, E. [Eurofins Scientific Analytics, Rue Pierre Adolphe Bobierre, 44323 Nantes Cedex 3 (France); Bensaid, F.F. [Eurofins Scientific Analytics, Rue Pierre Adolphe Bobierre, 44323 Nantes Cedex 3 (France); Lees, M. [Eurofins Scientific Analytics, Rue Pierre Adolphe Bobierre, 44323 Nantes Cedex 3 (France); Smeyers-Verbeke, J. [ChemoAC, FABI, Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Massart, D.L. [ChemoAC, FABI, Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Vander Heyden, Y. [ChemoAC, FABI, Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium)]. E-mail: yvanvdh@vub.ac.be

    2005-11-03

    A data set consisting of fourteen isotopic ratios or quantities derived from such ratios for samples of acetylsalicylic acid (aspirin), commercialized by various pharmaceutical companies from different countries, was analyzed. The goal of the data analysis was to explore whether results can be linked to geographical origin or other features such as different manufacturing processes, of the samples. The methods of data analysis used were principal component analysis (PCA), robust principal component analysis (RPCA), projection pursuit (PP) and multiple factor analysis (MFA). The results do not seem to depend on geographic origin, except for some samples from India. They do depend on the pharmaceutical companies. Moreover, it seems that the samples from certain pharmaceutical companies form clusters of similar samples, suggesting that there is some common feature between those pharmaceutical companies. Variable selection performed by means of MFA showed that the number of variables can be reduced to five without loss of information.

  2. Radiogenic isotopes in enriched mid-ocean ridge basalts from Explorer Ridge, northeast Pacific Ocean

    Science.gov (United States)

    Cousens, Brian; Weis, Dominique; Constantin, Marc; Scott, Steve

    2017-09-01

    Extreme gradients in topography related to variations in magma supply are observed on the Southern Explorer Ridge (SER), part of the northern Juan de Fuca ridge system. We report radiogenic isotope (Pb, Sr, Nd, Hf) and geochemical data for twenty-four basalt whole-rock and glass samples collected from the length of the SER and from Explorer Deep, a rift to the north of the SER. Lavas from the SER form a north-south geochemical gradient, dominated by E-MORB at the northern axial high, and range from T-MORB to N-MORB towards the southern deepest part of the ridge. Linear relationships between incompatible element ratios and isotopic ratios in MORB along the ridge are consistent with mixing of magmas beneath the ridge to generate the geographic gradient from E- to N-MORB. The E-MORB have high Sr and Pb, and low Nd and Hf isotopic ratios, typical of enriched mantle that includes a FOZO or HIMU isotopic component. The West Valley and Endeavour segments of the northern Juan de Fuca ridge also include this isotopic component, but the proportion of the FOZO or HIMU component is more extreme in the SER basalts. The FOZO or HIMU component may be garnet-bearing peridotite, or a garnet pyroxenite embedded in peridotite. Recycled garnet pyroxenite better explains the very shallow SER axial high, high Nb/La and La/Sm, and the ;enriched; isotopic compositions.

  3. Hg stable isotope analysis by the double-spike method.

    Science.gov (United States)

    Mead, Chris; Johnson, Thomas M

    2010-06-01

    Recent publications suggest great potential for analysis of Hg stable isotope abundances to elucidate sources and/or chemical processes that control the environmental impact of mercury. We have developed a new MC-ICP-MS method for analysis of mercury isotope ratios using the double-spike approach, in which a solution containing enriched (196)Hg and (204)Hg is mixed with samples and provides a means to correct for instrumental mass bias and most isotopic fractionation that may occur during sample preparation and introduction into the instrument. Large amounts of isotopic fractionation induced by sample preparation and introduction into the instrument (e.g., by batch reactors) are corrected for. This may greatly enhance various Hg pre-concentration methods by correcting for minor fractionation that may occur during preparation and removing the need to demonstrate 100% recovery. Current precision, when ratios are normalized to the daily average, is 0.06 per thousand, 0.06 per thousand, 0.05 per thousand, and 0.05 per thousand (2sigma) for (202)Hg/(198)Hg, (201)Hg/(198)Hg, (200)Hg/(198)Hg, and (199)Hg/(198)Hg, respectively. This is slightly better than previously published methods. Additionally, this precision was attained despite the presence of large amounts of other Hg isotopes (e.g., 5.0% atom percent (198)Hg) in the spike solution; substantially better precision could be achieved if purer (196)Hg were used.

  4. uranium and thorium exploration by geophysical methods

    International Nuclear Information System (INIS)

    Yueksel, F.A.; Kanli, A.I.

    1997-01-01

    Radioactivity is often measured from the ground in mineral exploration. If large areas have to be investigated, it is often unsuitable to carry out the measurements with ground-bound expeditions. A geophysical method of gamma-ray spectrometry is generally applied for uranium exploration. Exploration of uranium surveys were stopped after the year of 1990 in Turkey. Therefore the real potential of uranium in Turkey have to be investigated by using the geophysical techniques

  5. Generator Coordinate Method Analysis of Xe and Ba Isotopes

    Science.gov (United States)

    Higashiyama, Koji; Yoshinaga, Naotaka; Teruya, Eri

    Nuclear structure of Xe and Ba isotopes is studied in terms of the quantum-number projected generator coordinate method (GCM). The GCM reproduces well the energy levels of high-spin states as well as low-lying states. The structure of the low-lying states is analyzed through the GCM wave functions.

  6. Determination of photooxygenation products of rotenone with isotope dilution method

    International Nuclear Information System (INIS)

    Chubachi, Mitsuo; Hamada, Masayuki

    1975-01-01

    When rotenone dissolved in certain solvent was photochemically oxidized, rotenolones, dehydrorotenone and rotenonone were obtained as main products. In order to determine the quantitative yields of these compounds in photooxygenation products, four compounds mentioned above were labeled with carbon-14 and the isotope dilution method by these labeled compounds was applied to the product analysis. (auth.)

  7. Overview on recent developments: alternative isotope production methods in Canada

    International Nuclear Information System (INIS)

    Huynh, K.

    2012-01-01

    The purpose of this paper is to provide an update on the Government of Canada's programs in alternative isotope production methods for securing supply of technetium 99m for Canadians. The supply disruptions of isotopes in 2007 and 2009/2010 caused by unplanned outages at AECL's National Research Universal (NRU) reactor highlighted the fragility of the supply chain that delivers medical isotopes, specifically Technetium 99m (Tc99m) to patients in Canada and globally. Tc99m, which is derived from its parent, molybdenum99 (Mo99) is the most widely used medical isotope for imaging, and accounts for 80 percent of nuclear medicine diagnostic procedures. Prior to the outage, nearly all the Mo99 produced for the world market came from five aging government owned research reactors in Canada, France, the Netherlands, Belgium and South Africa. The NRU, the largest of these, produced about 30 to 40 percent of the world supply of isotopes prior to 2009 - since its return to service in 2010, its world market share is estimated at 15 to 20%.

  8. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances

  9. Method of deuterium isotope separation and enrichment

    International Nuclear Information System (INIS)

    Benson, S.W.

    1978-01-01

    A method of separating deuterium, i.e., heavy hydrogen, from certain naturally occurring sources using tuned infrared lasers to selectively decompose specified classes of organic molecules (i.e., RX) into enriched molecular products containing deuterium atoms is described. The deuterium containing molecules are easily separated from the starting material by absorption, distillation or other simple chemical separation techniques and methods. After evaporation such deuterium containing molecules can be burned to form water with an enriched deuterium content or pyrolyzed to form hydrogen gas with an enriched deuterium content. The undecomposed molecules and the other reaction products which are depleted of their deuterium containing species can be catalytically treated, preferably using normal water, to restore the natural abundance of deuterium and such restored molecules can then be recycled

  10. Reductive methods for isotopic labeling of antibiotics

    International Nuclear Information System (INIS)

    Champney, W.S.

    1989-01-01

    Methods for the reductive methylation of the amino groups of eight different antibiotics using 3 HCOH or H 14 COH are presented. The reductive labeling of an additional seven antibiotics by NaB 3 H 4 is also described. The specific activity of the methyl-labeled drugs was determined by a phosphocellulose paper binding assay. Two quantitative assays for these compounds based on the reactivity of the antibiotic amino groups with fluorescamine and of the aldehyde and ketone groups with 2,4-dinitrophenylhydrazine are also presented. Data on the cellular uptake and ribosome binding of these labeled compounds are also presented

  11. Optimizing design parameter for light isotopes separation by distillation method

    International Nuclear Information System (INIS)

    Ahmadi, M.

    1999-01-01

    More than methods are suggested in the world for producing heavy water, where between them chemical isotopic methods, distillation and electro lys are used widely in industrial scale. To select suitable method for heavy water production in Iran, taking into consideration, domestic technology an facilities, combination of hydrogen sulphide-water dual temperature process (Gs) and distillation (D W) may be proposed. Natural water, is firstly enriched up to 15 a% by G S process and then by distillation unit is enriched up to the grade necessary for Candu type reactors (99.8 a%). The aim of present thesis, is to achieve know-how, optimization of design parameters, and executing basic design for water isotopes separation using distillation process in a plant having minimum scale possible. In distillation, vapour phase resulted from liquid phase heating, is evidently composed of the same constituents as liquid phase. In isotopic distillation, the difference in composition of constituents is not considerable. In fact alteration of constituents composition is so small that makes the separation process impossible, however, direct separation and production of pure products without further processing which becomes possible by distillation, makes this process as one of the most important separation processes. Profiting distillation process to produce heavy water is based on difference existing between boiling point of heavy and light water. The trends of boiling points differences (heavy and light water) is adversely dependant with pressure. As the whole system pressure decreases, difference in boiling points increases. On the other hand according to the definition, separation factor is equal to the ratio of pure light water vapour pressure to that of heavy water, or we can say that the trend of whole system pressure decrease results in separation factor increase, which accordingly separation factor equation to pressure variable should be computed firstly. According to the

  12. Natural isotope technique for the exploration and exploitation of ground water

    International Nuclear Information System (INIS)

    Zainal Abidin; Hudi Hastowo; Aang Hanafiah

    2007-01-01

    In line with the condition of climate and hydrology, Indonesia has a fast amount of aquifers which are sources of ground water. In several areas large number of springs occurred with small to large debits which is a sign of ground water potential. Ground water is a potential reservoir to be use at maximum for several purposes such as drinking water, industry and tourism. Large cities such as Jakarta, Bandung and others depend on ground water for their industries and hotels. The exploitation of ground water use has to be controlled and monitoring of a management system have to be done. Research carried out only on the exploitation of geophysics and hydrology showed that the amount of ground water reservoirs is not enough to be used when it comes to justification to explore it. Other parameters are still be needed which are the origins and dating of the ground water, these last two factors mentioned have to be taken into consideration in the system of conversion and balance of water. An alternative technology to determine the two factors mentioned in a short time is the natural isotope technique of 18 O, 2 H and 14 C. This technique is used to determine the origin of water, and isotope 14 C is carried out to determine the age of ground water. Isotopes 18 H and 2 H are stable isotopes in the form of water and is integrated in the hydrological cycle. Their specific concentrations in rain water at several elevations are used as fingerprints to locate the area of ground water supplement and its origin. Isotope 14 C is a natural radioactive isotope with a half-life of 5.730 years and is found in the hydrology cycle and enters the ground water system through CO 2 gas which is dissolved in water. 14 C isotope could determine the age of ground water and is also able to indicate the potential/amount of ground water. Studies of exploration and exploration monitoring of ground water should be an integrated study by geohydrology, geophysics and isotope and could be a solution of

  13. Exploring methods in information literacy research

    CERN Document Server

    Lipu, Suzanne; Lloyd, Annemaree

    2007-01-01

    This book provides an overview of approaches to assist researchers and practitioners to explore ways of undertaking research in the information literacy field. The first chapter provides an introductory overview of research by Dr Kirsty Williamson (author of Research Methods for Students, Academics and Professionals: Information Management and Systems) and this sets the scene for the rest of the chapters where each author explores the key aspects of a specific method and explains how it may be applied in practice. The methods covered include those representing qualitative, quantitative and mix

  14. Geothermal exploration using the magnetotelluric method

    NARCIS (Netherlands)

    van Leeuwen, W.A.

    2016-01-01

    One of the requirements to realize electricity production from geothermal energy in the Netherlands is the exploration of the deep subsurface. Currently, detailed geological information below 5 kilometer is sparse. The magnetotelluric (MT) method, a passive electromagnetic method, is a candidate to

  15. Exploration of the Effectiveness of Tactile Methods

    Science.gov (United States)

    Aldajani, Neda F.

    2016-01-01

    This paper introduces the tactile method and aims to explore the effectiveness of using tactile methods with students who are blind and visually impaired. Although there was limited research about using this strategy, all of the research agrees that using tactile is one of the best ways for students who are blind and visually impaired to be…

  16. Method of deuterium isotope separation and enrichment

    International Nuclear Information System (INIS)

    Benson, S.W.

    1979-01-01

    A method is described for separating and enriching deuterium containing molecules comprising the steps of: providing a source of organic molecules containing a normal abundance of deuterium atoms, the organic molecules having a structural formula RX, in which R is an organic radical selected from ethyl, isopropyl, t-butyl and 3-cyclopentenyl, and in which X is selected from F, Cl, Br and OH, and wherein R represents 3-cyclopentenyl, X may additionally represent H; exposing the molecules to the radiation of at least one pulsed infrared laser source which has been specifically tuned and focussed to selectively decompose RX molecules containing deuterium to form an enriched olefin specie containing deuterium, and HX; and separating the deuterium enriched olefin specie from the undecomposed deuterium depleted RX molecules and HX. (author)

  17. A method of computerised isotope dynamic proctography

    International Nuclear Information System (INIS)

    Papachrysostomou, M.; Ferrington, C.; Merrick, M.V.; Smith, A.N.; Western General Hospital, Edinburgh; Griffin, T.M.J.

    1992-01-01

    Patients with long-standing constipation were examined by radioisotope proctography. A radiolabelled synthetic potato mash was inserted intrarectally and the dynamic changes during simulated defaecation recorded using a gamma-camera. Computer images from the stored data illustrate changes in the anorectal angle and pelvic floor. The median (and 95% confidence intervals) of the anorectal angles were: At rest 105deg (101deg, 116deg), on voluntary contraction of the pelvic floor by 'squeezing' 91deg (81deg, 98deg), on straining 120deg (107deg, 137deg) and during evacuation 126deg (116deg, 153deg). The pelvic floor movements were: Pelvic floor ascent on voluntary contraction 28 mm (9, 34 mm), pelvic floor descent on straining -8 mm (-14, -4 mm) and descent during evacuation -27 mm (-34, -11 mm). Useful additions to previous methods are measurement of the completeness of rectal evacuation 58% (42, 77 mm), the defaecation time 64 s (50, 138 s) and the defaecation rate 0.9%/s (0.4, 1.4%/s). (orig.)

  18. Analytical method for the isotopic characterization of soils

    International Nuclear Information System (INIS)

    Sibello Hernandez, Rita; Cozzella, Maria Letizia; Mariani, Mario

    2014-01-01

    The aim of this work was to develop an analytical method in order to determine the isotopic composition of different elements in soil samples and to determine the existence of contamination. The method used in the digestion of the samples was the EPA 3050B, and some metal concentration were determined including uranium and thorium. For elements with even lower concentrations such as plutonium and radium a treatment after mineralization by EPA, was necessary. The measurement technique used was mass spectrometry with quadrupole and plasma induced associated (ICP-MS). Results of the analysis performed in two laboratories showed a good correspondence. This method allowed to perform the isotopic characterization of studied soils and results showed that the studied soils do not present any local pollution and that the presence of plutonium-239, is due to global failure

  19. Isotope correlations for safeguards surveillance and accountancy methods

    International Nuclear Information System (INIS)

    Persiani, P.J.; Kalimullah.

    1983-01-01

    Isotope correlations corroborated by experiments, coupled with measurement methods for nuclear material in the fuel cycle have the potential as a safeguards surveillance and accountancy system. The US/DOE/OSS Isotope Correlations for Surveillance and Accountancy Methods (ICSAM) program has been structured into three phases: (1) the analytical development of Isotope Correlation Technique (ICT) for actual power reactor fuel cycles; (2) the development of a dedicated portable ICT computer system for in-field implementation, and (3) the experimental program for measurement of U, Pu isotopics in representative spent fuel-rods of the initial 3 or 4 burnup cycles of the Commonwealth Edison Zion -1 and -2 PWR power plants. Since any particular correlation could generate different curves depending upon the type and positioning of the fuel assembly, a 3-D reactor model and 2-group cross section depletion calculation for the first cycle of the ZION-2 was performed with each fuel assembly as a depletion block. It is found that for a given PWR all assemblies with a unique combination of enrichment zone and number of burnable poison rods (BPRs) generate one coincident curve. Some correlations are found to generate a single curve for assemblies of all enrichments and number of BPRs. The 8 axial segments of the 3-D calculation generate one coincident curve for each correlation. For some correlations the curve for the full assembly homogenized over core-height deviates from the curve for the 8 axial segments, and for other correlations coincides with the curve for the segments. The former behavior is primarily based on the transmutation lag between the end segment and the middle segments. The experimental implication is that the isotope correlations exhibiting this behavior can be determined by dissolving a full assembly but not by dissolving only an axial segment, or pellets

  20. Fission track method for uranium ore exploration

    International Nuclear Information System (INIS)

    Guo Shilun; Deng Xinlu; Sun Shengfen; Meng Wu; Zhang Pengfa; Hao Xiuhong

    1986-01-01

    The uranium concentrations in natural water collected in the fields of uranium ore exploration with fission track method have been determined. It shows that the results of fission track method are consistent with that of fluoro-colorimetry and laser fluorometry for the same samples of water with uranium concentration in the region of 10 -4 to 10 -8 g/l. For water samples with lower uranium concentration (≤10 -8 g/l), the fission track method can still give accurate or referential results, but the other two methods failed. The reproducibility of fission track method was checked and discussed by using samples collected in the same fields of uranium ore exploration. The effects of the concentration of the impurities in natural water on determination of uranium concentration were analysed and discussed as well

  1. Volatiles and Isotopes and the Exploration of Ancient and Modern Martian Habitability with the Curiosity Rover

    Science.gov (United States)

    Mhaffy, P. R.

    2015-01-01

    The Mars Science Laboratory Mission was designed to pave the way for the study of life beyond Earth through a search for a habitable environment in a carefully selected landing site on Mars. Its ongoing exploration of Gale Crater with the Curiosity Rover has provided a rich data set that revealed such an environment in an ancient lakebed [1]. Volatile and isotope measurements of both the atmosphere and solids contribute to our growing understanding of both modern and ancient environments.

  2. METHOD FOR PRODUCING ISOTOPIC METHANES AND PARTIALLY HALOGENATED DERIVATIVES THEROF

    Science.gov (United States)

    Frazer, J.W.

    1959-08-18

    A method is given for producing isotopic methanes and/ or partially halogenated derivatives. Lithium hydride, deuteride, or tritide is reacted with a halogenated methane or with a halogenated methane in combination with free halogen. The process is conveniently carried out by passing a halogenated methane preferably at low pressures or in an admixture with an inert gas through a fixed bed of finely divided lithium hydride heated initially to temperatures of 100 to 200 deg C depending upon the halogenated methane used.

  3. Isotopic method of leaks detection in oil pipelines

    International Nuclear Information System (INIS)

    Listwam, W.; Mottl, J.

    1974-01-01

    Isotopic method of leaks detection in oil pipelines of diameter 200-800 mm is described. Tracer is injected into pipeline in the form of CH 3 Br 82 . After few hours one or two detectors are passed through pipeline to detect leaks. Detector set consists of scintillation radiometer with Na I/Tl crystal, electronic blecks with one-channel analyzer, recorder and storage batteries. Detector set is built on integrated circuits. (Z.M.)

  4. Isotope correlations for safeguards surveillance and accountancy methods

    International Nuclear Information System (INIS)

    Persiani, P.J.; Kalimullah.

    1982-01-01

    Isotope correlations corroborated by experiments, coupled with measurement methods for nuclear material in the fuel cycle have the potential as a safeguards surveillance and accountancy system. The ICT allows the verification of: fabricator's uranium and plutonium content specifications, shipper/receiver differences between fabricator output and reactor input, reactor plant inventory changes, reprocessing batch specifications and shipper/receiver differences between reactor output and reprocessing plant input. The investigation indicates that there exist predictable functional relationships (i.e. correlations) between isotopic concentrations over a range of burnup. Several cross-correlations serve to establish the initial fuel assembly-averaged compositions. The selection of the more effective correlations will depend not only on the level of reliability of ICT for verification, but also on the capability, accuracy and difficulty of developing measurement methods. The propagation of measurement errors through the correlations have been examined to identify the sensitivity of the isotope correlations to measurement errors, and to establish criteria for measurement accuracy in the development and selection of measurement methods. 6 figures, 3 tables

  5. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Caso, R.

    1997-01-01

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  6. Continuous flow isotope ratio mass spectrometer (CF-IRMS) and its applications in hydrocarbon research and exploration

    International Nuclear Information System (INIS)

    Kalpana, G.; Patil, D.J.; Kumar, B.

    2004-01-01

    Stable isotope ratio mass spectrometers have been widely used to determine the isotopic ratios of light elements such as hydrogen, carbon, nitrogen, oxygen and sulphur. Continuous Flow Isotope Ratio Mass Spectrometry (CFIRMS) provides reliable data on nanomole amount of sample gas without the need for cryogenic trapping using cold fingers as in dual inlet isotope ratio mass spectrometer. High sample throughput is achieved as the system is configured with automated sample preparation devices and auto samplers. This paper presents a brief description of CFIRMS exploration

  7. Field Sample Preparation Method Development for Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    Leibman, C.; Weisbrod, K.; Yoshida, T.

    2015-01-01

    Non-proliferation and International Security (NA-241) established a working group of researchers from Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to evaluate the utilization of in-field mass spectrometry for safeguards applications. The survey of commercial off-the-shelf (COTS) mass spectrometers (MS) revealed no instrumentation existed capable of meeting all the potential safeguards requirements for performance, portability, and ease of use. Additionally, fieldable instruments are unlikely to meet the International Target Values (ITVs) for accuracy and precision for isotope ratio measurements achieved with laboratory methods. The major gaps identified for in-field actinide isotope ratio analysis were in the areas of: 1. sample preparation and/or sample introduction, 2. size reduction of mass analyzers and ionization sources, 3. system automation, and 4. decreased system cost. Development work in 2 through 4, numerated above continues, in the private and public sector. LANL is focusing on developing sample preparation/sample introduction methods for use with the different sample types anticipated for safeguard applications. Addressing sample handling and sample preparation methods for MS analysis will enable use of new MS instrumentation as it becomes commercially available. As one example, we have developed a rapid, sample preparation method for dissolution of uranium and plutonium oxides using ammonium bifluoride (ABF). ABF is a significantly safer and faster alternative to digestion with boiling combinations of highly concentrated mineral acids. Actinides digested with ABF yield fluorides, which can then be analyzed directly or chemically converted and separated using established column chromatography techniques as needed prior to isotope analysis. The reagent volumes and the sample processing steps associated with ABF sample digestion lend themselves to automation and field

  8. A Convenient Method for Estimation of the Isotopic Abundance in Uranium Bearing Samples

    International Nuclear Information System (INIS)

    AI -Saleh, F.S.; AI-Mukren, Alj.H.; Farouk, M.A.

    2008-01-01

    A convenient and simple method for estimation of the isotopic abundance in some uranium bearing samples using gamma-ray spectrometry is developed using a hyper pure germanium spectrometer and a standard uranium sample with known isotopic abundance

  9. Calcium Isotope Analysis with "Peak Cut" Method on Column Chemistry

    Science.gov (United States)

    Zhu, H.; Zhang, Z.; Liu, F.; Li, X.

    2017-12-01

    To eliminate isobaric interferences from elemental and molecular isobars (e.g., 40K+, 48Ti+, 88Sr2+, 24Mg16O+, 27Al16O+) on Ca isotopes during mass determination, samples should be purified through ion-exchange column chemistry before analysis. However, large Ca isotopic fractionation has been observed during column chemistry (Russell and Papanastassiou, 1978; Zhu et al., 2016). Therefore, full recovery during column chemistry is greatly needed, otherwise uncertainties would be caused by poor recovery (Zhu et al., 2016). Generally, matrix effects could be enhanced by full recovery, as other elements might overlap with Ca cut during column chemistry. Matrix effects and full recovery are difficult to balance and both need to be considered for high-precision analysis of stable Ca isotopes. Here, we investigate the influence of poor recovery on δ44/40Ca using TIMS with the double spike technique. The δ44/40Ca values of IAPSO seawater, ML3B-G and BHVO-2 in different Ca subcats (e.g., 0-20, 20-40, 40-60, 60-80, 80-100%) with 20% Ca recovery on column chemistry display limited variation after correction by the 42Ca-43Ca double spike technique with the exponential law. Notably, δ44/40Ca of each Ca subcut is quite consistent with δ44/40Ca of Ca cut with full recovery within error. Our results indicate that the 42Ca-43Ca double spike technique can simultaneously correct both of the Ca isotopic fractionation that occurred during column chemistry and thermal ionization mass spectrometry (TIMS) determination properly, because both of the isotopic fractionation occurred during analysis follow the exponential law well. Therefore, we propose the "peak cut" method on Ca column chemistry for samples with complex matrix effects. Briefly, for samples with low Ca contents, we can add the double spike before column chemistry, and only collect the middle of the Ca eluate and abandon the both sides of Ca eluate that might overlap with other elements (e.g., K, Sr). This method would

  10. Calculation of isotope selective excitation of uranium isotopes using spectral simulation method

    International Nuclear Information System (INIS)

    Al-Hassanieh, O.

    2009-06-01

    Isotope ratio enhancement factor and isotope selectivity of 235 U in five excitation schemes (I: 0→10069 cm - 1 →IP, II: 0 →10081 cm - 1 →IP, III: 0 →25349 cm - 1→ IP, IV: 0→28650 cm - 1 →IP, V: 0→16900 cm - 1 →34659 cm - 1 →IP), were computed by a spectral simulation approach. The effect of laser bandwidth and Doppler width on the isotope ratio enhancement factor and isotope selectivity of 235 U has been studied. The photoionization scheme V gives the highest isotope ratio enhancement factor. The main factors which effect the separation possibility are the isotope shift and the relative intensity of the transitions between hyperfine levels. The isotope ratio enhancement factor decreases exponentially by increasing the Doppler width and the laser bandwidth, where the effect of Doppler width is much greater than the effect of the laser bandwidth. (author)

  11. Comparative determination of sucrose content in sugar beet by polarimetric and isotope dilution methods

    Energy Technology Data Exchange (ETDEWEB)

    Malec, K; Szuchnik, A [Institute of Nuclear Research, Warsaw (Poland); Rydel, S; Walerianaczyk, E [Instytut Przemyslu Cukrowniczego, Warsaw (Poland)

    1976-01-01

    The comparative determination of sucrose content in sugar beets has been investigated by following methods: polarimetric, direct isotope dilution and double carrier-isotope dilution analysis. Basing upon the obtained results it has been ascertained, that in the case of worse quality beets the polarimetric determinations differ greatly from isotopic data.

  12. Anatomical exploration of peritoneal cavity an isotopic method

    International Nuclear Information System (INIS)

    Wampach, H.; Canivet, E.; Chanard, J.; Liehn, J.C.

    1997-01-01

    The ambulatory continuous peritoneal dialysis (ACPD) is a means of treatment of terminal chronic renal insufficiency. It implies an optimal filling up and clearing of peritoneal cavity without hernial leakage,nor fistulas with gliding fluids. The aim of this study was to evidence the badly-drained peritoneal regions or the extra-peritoneal communications, as sources of complications of ACPD. The study was conducted on 18 patients without abdominal surgical antecedents, treated by ACPD. The group contained 2 patients with recent clinical inguinal hernias, subject to ACPD and 2 patients presenting an inguinal weighting without clinically discernible hernia. Two static acquisitions, in dorsal decubitus, of the abdomen were successively performed with a frontal anterior incidence of 300 s duration: one, immediately after infusion, and the other after the dialyzer clearing, labelled by 37 MBq of colloid-Tc. The following results were obtained: confirmation of 2 known hernias, discovery of a hernia implying surgical treatment in two patients with inguinal weighting and a bad visualisation of the Douglas' trap, favoring a bad drain, in case one patient. In conclusion, this technically simple examination allowed to detect two cases of inguinal hernia, otherwise not evidenced, sources of later complication of ACPD. Consequently, an earlier and simple surgical treatment has been performed. This examination could be useful in patients before being subject to ACPD

  13. Method of preparing mercury with an arbitrary isotopic distribution

    Science.gov (United States)

    Grossman, M.W.; George, W.A.

    1986-12-16

    This invention provides for a process for preparing mercury with a predetermined, arbitrary, isotopic distribution. In one embodiment, different isotopic types of Hg[sub 2]Cl[sub 2], corresponding to the predetermined isotopic distribution of Hg desired, are placed in an electrolyte solution of HCl and H[sub 2]O. The resulting mercurous ions are then electrolytically plated onto a cathode wire producing mercury containing the predetermined isotopic distribution. In a similar fashion, Hg with a predetermined isotopic distribution is obtained from different isotopic types of HgO. In this embodiment, the HgO is dissolved in an electrolytic solution of glacial acetic acid and H[sub 2]O. The isotopic specific Hg is then electrolytically plated onto a cathode and then recovered. 1 fig.

  14. Unravelling the sulphur isotope systematics of an alkaline magmatic province: implications for REE mineralization and exploration

    Science.gov (United States)

    Hutchison, W.; Finch, A.; Boyce, A.; Friis, H.; Borst, A. M.; Horsburgh, N. J.

    2017-12-01

    Some of the world's best alkaline rare earth element (REE) deposits are formed in magmatic systems that are sealed (i.e., those that are autometasomatised and maintain reducing conditions). Conversely, in open systems where oxidizing fluids infiltrate, it is commonly assumed that REE are redistributed over a wider (less concentrated) zone. Sulphur isotope fractionation is sensitive to variations in temperature and redox, and, although sulphide minerals are relatively abundant in alkaline systems, there have been few attempts to test these hypotheses and develop a sulphur isotope proxy for alkaline metasomatism and formation of associated REE deposits. The Gardar Rift Province in southern Greenland was volcanically active in two periods between 1300 and 1100 Ma and is an ideal natural laboratory to explore sulphur isotope systematics because a near-complete alkaline magmatic lineage is exposed. We present new δ34S from across the province with a particular focus on three alkaline systems (Ilímaussaq, Motzfeldt and Ivigtût) that also host major REE deposits. Primitive mafic rocks from regional Gardar dykes and lavas have a restricted range of δ34S between 0 and 3 ‰ and fractional crystallization imparts no observable change in δ34S. In a few cases high-δ34S rocks (>15 ‰) occur when intrusive units have assimilated local sedimentary crust (δ34S = 25 ‰). Most δ34S variation takes place in the roof zones of alkaline intrusions during late-magmatic and hydrothermal stages, and we identify clear differences between the complexes. At Ilímaussaq, where the magmatic series is exceptionally reduced (below QFM buffer), roof zone δ34S remains narrow (0-3 ‰). At Motzfeldt, a more open oxidizing roof zone (MH buffer), δ34S ranges from -12 ‰ in late-stage fluorite veins to +12 ‰ where local crust has been assimilated. Ivigtût is intermediate between these end-members varying between -5 to +5 ‰. The δ34S variations primarily relate to temperature and

  15. System and method for high precision isotope ratio destructive analysis

    Science.gov (United States)

    Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

    2013-07-02

    A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

  16. Calculation of isotopic mass and energy production by a matrix operator method

    International Nuclear Information System (INIS)

    Lee, C.E.

    1976-08-01

    The Volterra method of the multiplicative integral is used to determine the isotopic density, mass, and energy production in linear systems. The solution method, assumptions, and limitations are discussed. The method allows a rapid accurate calculation of the change in isotopic density, mass, and energy production independent of the magnitude of the time steps, production or decay rates, or flux levels

  17. Evaluation of isotopic dilution method for measuring N2 fixation in azolla: comparison with other methods

    International Nuclear Information System (INIS)

    Sah, R.N.; Goyal, S.S.; Rains, D.W.; Paige, D.F.

    1989-01-01

    An isotopic dilution method that overcomes the drawbacks of commonly used methods for measuring N 2 fixation by aquatic N‐fixers such as Azolla pinnata‐Anabaena azollae association (Azolla) is presented. The method was compared with 15 N2 gas (while maintaining CO 2 ) and the difference methods of measuring N 2 fixation. The isotopic dilution method was used for two conditions: a. For 15 N‐free growth medium, Azolla was pre‐enriched with 15 N, and N 2 fixation was determined by measuring the dilution of 15 N in the tissue. b. For the growth medium containing N, N2 fixation was determined by providing 15 N enriched ammonium sulfate in the growth medium and measuring 15 N to 14 N ratio in the tissue. An airtight chamber, necessary for 15 N 2 gas and acetylene reduction methods, was not representative of the growing environment of Azolla. Temperature in the airtight chamber was far from uniform and CO 2 was rapidly depleted. The isotopic dilution method is simpler, relatively inexpensive, subject to fewer errors and applicable to more diverse conditions, and yet was as accurate as 15 N2‐gas method. (author)

  18. Method for enriching and separating heavy hydrogen isotopes from substance streams containing such isotopes by means of isotope exchange

    International Nuclear Information System (INIS)

    Knochel, A.; Eggers, I.; Klatte, B.; Wilken, R. D.

    1985-01-01

    A process for enriching and separating heavy hydrogen isotopes having a heavy hydrogen cation (deuterium and/or tritium) from substance streams containing them, wherein the respectively present hydrogen isotopes are exchanged in chemical equilibria. A protic, acid solution containing deuterium and/or tritium is brought into contact with a value material from the group of open-chained polyethers or aminopolyethers, macro-monocyclic or macro-polycyclic polyethers, macro-monocyclic or macro-polycyclic amino polyethers, and mixtures of these values, in their free or proton salt form to form a reaction product of the heavy hydrogen cation with the value or value salt and bring about enrichment of deuterium and/or tritium in the reaction product. The reaction product containing the value or value salt is separated from the solution. The separated reaction product is treated to release the hydrogen isotope(s) to be enriched in the form of deuterium oxide (HDO) and/or tritium oxide (HTO) by regenerating the value or its salt, respectively. The regenerated value is returned for reuse

  19. Synergy between experimental and theoretical methods in the exploration of homogeneous transition metal catalysis

    DEFF Research Database (Denmark)

    Lupp, Daniel; Christensen, Niels Johan; Fristrup, Peter

    2014-01-01

    n this Perspective, we will focus on the use of both experimental and theoretical methods in the exploration of reaction mechanisms in homogeneous transition metal catalysis. We briefly introduce the use of Hammett studies and kinetic isotope effects (KIE). Both of these techniques can be complem......n this Perspective, we will focus on the use of both experimental and theoretical methods in the exploration of reaction mechanisms in homogeneous transition metal catalysis. We briefly introduce the use of Hammett studies and kinetic isotope effects (KIE). Both of these techniques can...... be complemented by computational chemistry – in particular in cases where interpretation of the experimental results is not straightforward. The good correspondence between experiment and theory is only possible due to recent advances within the applied theoretical framework. We therefore also highlight...

  20. An innovative method for extracting isotopic information from low-resolution gamma spectra

    International Nuclear Information System (INIS)

    Miko, D.; Estep, R.J.; Rawool-Sullivan, M.W.

    1998-01-01

    A method is described for the extraction of isotopic information from attenuated gamma ray spectra using the gross-count material basis set (GC-MBS) model. This method solves for the isotopic composition of an unknown mixture of isotopes attenuated through an absorber of unknown material. For binary isotopic combinations the problem is nonlinear in only one variable and is easily solved using standard line optimization techniques. Results are presented for NaI spectrum analyses of various binary combinations of enriched uranium, depleted uranium, low burnup Pu, 137 Cs, and 133 Ba attenuated through a suite of absorbers ranging in Z from polyethylene through lead. The GC-MBS method results are compared to those computed using ordinary response function fitting and with a simple net peak area method. The GC-MBS method was found to be significantly more accurate than the other methods over the range of absorbers and isotopic blends studied

  1. Method for adding additional isotopes to actinide-only burnup credit

    International Nuclear Information System (INIS)

    Lancaster, D.B.; Fuentes, E.; Kang, C.

    1998-01-01

    The Topical Report on Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel Packages requires computer code validation to be performed against a benchmark set of chemical assays for isotopic concentration and against a benchmark set of critical experiments for package criticality. Both sets contain all the isotopes included in the methodology. The chemical assays used include the uranium and plutonium isotopes, while the critical experiments were composed of UO 2 or MOX rods, covering the isotopes in the actinide only approach. Since other isotopes are not included in the validation benchmark sets, it would be necessary to justify both the content and worth of any additional isotope for which burnup credit is to be taken (i.e., both the concentration and criticality effect of each particular isotope must be validated). A method is proposed here that can be used for any number of additional isotopes. As does the actinide-only burnup credit methodology, this method makes use of chemical assay data to establish the conservatism in the prediction of each isotope's concentration. Criticality validation is also performed using a benchmark set of UO 2 and MOX critical experiments, where the additional isotopes are validated using worth experiments to conservatively account for any uncertainty in their cross sections. The remaining requirements (analysis and modeling parameters, loading criteria generation, and physical implementation and controls) are performed exactly as described in the actinide-only burnup credit methodology. This report provides insight into each particular requirement in the new methodology

  2. Isotope methods for the control of food products and beverages

    Energy Technology Data Exchange (ETDEWEB)

    Guillou, C; Reniero, F [Commission of the European Communities, Joint Research Centre, Ispra (Italy)

    2001-10-01

    The measurement of the stable isotope contents provides useful information for the detection of many frauds in food products. Nuclear magnetic resonance (NMR) and isotopic ratio mass spectroscopy (IRMS) are the two main analytical techniques used for the determination of stable isotope contents in food products. These analytical techniques have been considerably improved in the last years offering wider possibilities of applications for food analysis. A review of the applications for the control of food products and beverages is presented. The need for new reference materials is discussed. (author)

  3. Isotope methods for the control of food products and beverages

    International Nuclear Information System (INIS)

    Guillou, C.; Reniero, F.

    2001-01-01

    The measurement of the stable isotope contents provides useful information for the detection of many frauds in food products. Nuclear magnetic resonance (NMR) and isotopic ratio mass spectroscopy (IRMS) are the two main analytical techniques used for the determination of stable isotope contents in food products. These analytical techniques have been considerably improved in the last years offering wider possibilities of applications for food analysis. A review of the applications for the control of food products and beverages is presented. The need for new reference materials is discussed. (author)

  4. Study on atmospheric hydrogen enrichment by cryopump method and isotope separation by gas chromatography

    International Nuclear Information System (INIS)

    Taniyama, Yuki; Momoshima, Noriyuki

    2001-01-01

    To obtain the information of source of atmospheric hydrogen tritium an analysis of tritium isotopes is thought to be effective. So an atmospheric hydrogen enrichment apparatus and a cryogenic gas chromatographic column were made. Experiments were carried out to study the performance of cryopump to enrich atmospheric hydrogen and the column to separate hydrogen isotopes that obtained by cryopump method. The cryopump was able to process about 1000 1 atmosphere and the column was able to separate hydrogen isotopes with good resolution. (author)

  5. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  6. Applications of stable isotopes and radioisotopes in the exploration and reservoir management of Philippine geothermal fields

    International Nuclear Information System (INIS)

    Ferrer, H.P.; Alvis-Isidro, R.R.

    1996-01-01

    The development of indigenous geothermal energy resources is currently one of the primary thrusts of the country's energy program. Presently, the Philippines has a total of geothermal generating capacity of about 1400 MWe. This comprises about 20% of the total energy mix and electricity requirements of the country. By 1998, an additional capacity of about 500 MWe will be commissioned, and the PHilippines would be generating 1900 MWe of electricity from geothermal energy resources. From 1990 to 1993, PNOC EDC (Philippine National Oil Company, Energy Development Corporation) has been granted a research contract by the International Atomic Energy Agency (IAEA). The Company has also been a recipient since 1991 of an IAEA Technical Assistance on the use of stable isotope techniques in geothermal hydrology. Stable isotopes, particularly 18 O and 2 H, in conjunction with other geochemical parameters and geological and geophysical data, have been used to: a) establish the local meteoric water line; b) determine the origin of geothermal fluids; c) delineate the elevation of recharge of geothermal and ground water systems; d) confirm pre-exploitation hydrochemical models; e) identify physical and chemical processes due to exploitation of the geothermal resource (i.e. reinjection fluid returns, incursion of cold meteoric water, boiling due to pressure drawdown and mixing with acidic steam condensates); and, f) estimate reservoir temperatures. Techniques using radioisotopes, such as 14 C, have also been used for the age-dating of charred wood samples collected from some of our geothermal exploration areas. The detection of 3 H has also been used as an indicator for the incursion of recent cold meteoric water into the geothermal system. Tracer studies using 131 I, have also been previously carried out, in coordination with the Philippine Nuclear Research Institute, to determine local hydrology and flow paths of reinjected water in some of our geothermal fields

  7. Application of helium isotopes in shallow groundwaters for geothermal energy exploration in the Upper Rhine Graben

    International Nuclear Information System (INIS)

    Freundt, Florian

    2017-01-01

    The helium isotope system is an established tool in hydrology for identifying mantle fluids in deep aquifers. This study applies the helium tracer system for the first time in shallow, unconfined aquifers of the Upper Rhine Graben. The Graben is a part of the Cenozoic Rift system of Western and Central Europe, a continental rift zone with unusually high geothermal gradients, making it an ideal region of Germany for geothermal energy development. The aim of this study is to develop a suite of natural groundwater tracers able to achieve a cost and effort reduction in geothermal prospection. The 3 He/ 4 He-ratio is therefore applied, as part of a multi-tracer approach including 3 H, δ 18 O, δ 2 H, δ 13 C, 14 C and 222 Rn, to identify and locate fault zones with suitable permeabilities for power plant operation. Three target areas along the graben were studied, each located on one of the main fault lines. A mantle-derived helium signature could be identified and separated from tritiogenic helium in a shallow aquifer in the north-west of the Graben. The mixing component of mantle-derived fluid in the shallow groundwater is calculated to reach up to 5%, based on the analysis of the 3 He/ 4 He isotope system. The employed method proves that the local permeability of the fault zone is high. The origin of the locally occurring upwelling of salinated water can be redetermined by the data.

  8. Adsorption methods for hydrogen isotope storage on zeolite sieves

    International Nuclear Information System (INIS)

    Cristescu, Ioana; Cristescu, Ion; Vasut, Felicia; Brad, Sebastian; Lazar, Alin

    2001-01-01

    Adsorption molecular sieves and activated carbon were used for hydrogen isotopes. The adsorption process proceeds at liquid nitrogen and liquid hydrogen temperatures. The synthetic zeolites have similar properties as natural zeolites, but they have a regular pore structure and affinity for molecules of different size with defined shapes. Experimental results obtained at liquid nitrogen and liquid hydrogen temperatures evidenced the efficient behavior of the activated carbon and zeolite sieves for hydrogen isotope temporary storage. (authors)

  9. Hydrogen isotope recovering and reutilizing method and its device

    International Nuclear Information System (INIS)

    Ide, Takahiro.

    1988-01-01

    Purpose: To enable safety and convenient recovery and reutilization of gaseous tritium and other hydrogen isotopes. Constitution: Two kinds of metal hydrides different from each other in the dissociation pressure at an identical temperature are combined, in which a metal hydride of higher dissociation pressure is used for recovery and reutilization for most portion of gaseous hydrogen isotope gases, while the metal hydride of lower dissociation pressure is used for the recovery and reutilization of the remaining gaseous hydrogen isotopes. This enables to extremely lower the concentration of the remaining gaseous hydrogen isotopes, that is, the concentration of tritium in the recoverying system. In addition, since the heating temperature required for releasing the gaseous hydrogen isotopes absorbed in both of the metal hydrides is within such a range as causing no problem for the permeation of the gaseous hydrogen isotopes, there is no requirement for the countermeasure to tritium permeation or the facility for recovering permeated tritium and there is no problem for the material degradation due to the heating at high temperature. (Kawakami, Y.)

  10. Semiempirical method to determine the uranium isotopic compositions

    International Nuclear Information System (INIS)

    Tegas Sutondo

    2008-01-01

    In a nuclear reactor design calculation, some variations of U 235 enrichment are commonly needed. This will affect the isotopic compositions of the 3 main uranium isotopes i.e. U 234 , U 235 and U 238 for the respective enrichment. Due to the limited compositions data available, it is urgent to make an approximate way that can be used to determine the compositions of the 3 isotopes, for the desired enrichments. This paper presents the theoretical background used for constructing a semi empirical formula to estimate the composition of the 3 uranium isotopes as a function of U 235 enrichment, obtained based on the measurement data available. Based on the available data, and the lack of compositions data within the enrichment range between 3.5 % and around 12 %, it is concluded that 2 separate linear equations i.e. for ≤ 3.5 % and ≥ 3.5 % might be needed for U 235 isotope. For the U 234 isotope, a polynomial equation of 4 th order is well suited to be used for the whole range of enrichment between 0.711 % and 20 %, whilst for higher enrichment (> 20 %), a power function seems to give a better approach. The composition of U 238 can then be determined from the U 235 and U 234 composition at the desired enrichment of U 235 . (author)

  11. Spectral isotopic methods of determining nitrogen and carbon in plant specimens with laser volatization

    International Nuclear Information System (INIS)

    Lazeeva, G.S.

    1986-01-01

    Methods have been devised for the local determination of nitrogen and carbon isotope compositions in plant specimens, which provide separate and joint determination. Local laser evaporation has been combined with spectroscopic determination of the isotope compositions in the gas phase. A continuous-wave CO 2 laser is preferable for the local evaporation; the carbon isotope composition may be determined directly on the sum of the evaporation products, whereas nitrogen must first be separated as N 2 . Methods have also been developed for the local determination of total nitrogen and carbon in a sample with isotope dilution on the basis of laser evaporation. In order to eliminate systematic errors in determining total carbon in plant material, an evaporation method free from a rim has been devised. These methods have been used in determining isotope concentration profiles in plant specimens grown in experiments employing labeled nitrogen and carbon

  12. Pb and Sr isotopic compositions of ancient pottery: a method to discriminate production sites

    International Nuclear Information System (INIS)

    Zhang Xun; Chen Jiangfeng; Ma Lin; He Jianfeng; Wang Changsui; Qiu Ping

    2004-01-01

    The discriminating of production sites of ancient pottery samples using multi-isotopic systematics was described. Previous work has proven that Pb isotopic ratios can be used for discriminating the production sites of ancient pottery under certain conditions. The present work suggests that although Nd isotopic ratios are not sensitive to the production sites of ancient pottery, Sr isotopic ratios are important for the purpose. Pb isotopic ratios are indistinguishable for the pottery excavated from the Jiahu relict, Wuyang, Henan Province and for famous Qin Terra-cotta Figures. But, the 87 Sr/ 86 Sr ratios for the former (about 0.715) are significantly lower than that of the latter (0.717-0.718). The authors concluded that a combined use of Pb and Sr isotopes would be a more powerful method for discriminating the production site of ancient pottery. (authors)

  13. Design study of fuel circulating system using Pd-alloy membrane isotope separation method

    International Nuclear Information System (INIS)

    Naito, T.; Yamada, T.; Yamanaka, T.; Aizawa, T.; Kasahara, T.; Nishikawa, M.; Asami, N.

    1980-01-01

    Design study on the fuel circulating system (FCS) for a tokamak experimental fusion reactor (JXFR) has been carried out to establish the system concept, to plan the development program, and to evaluate the feasibility of diffusion system. The FCS consists of main vacuum system, fuel gas refiners, isotope separators, fuel feeders, and auxiliary systems. In the system design, Pd-alloy membrane permeation method is adopted for fuel refining and isotope separating. All impurities are effectively removed and hydrogen isotopes are sufficiently separated by Pd-alloy membrane. The isotope separation system consists of 1st (47 separators) and 2nd (46 separators) cascades for removing protium and separating deuterium, respectively. In the FCS, while cryogenic distillation method appears to be practicable, Pd-alloy membrane diffusion method is attractive for isotope separation and refining of fuel gas. The choice will have to be based on reliability, economic, and safety analyses

  14. Kinetic investigation of heterogeneous catalytic reactions by means of the kinetic isotope method

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, F; Dermietzel, J [Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung

    1978-09-01

    The application of the kinetic isotope method to heterogeneous catalytic processes is possible for surface compounds by using the steady-state relation. However, the characterization of intermediate products becomes ambiguous if sorption rates are of the same order of magnitude as surface reactions rates. The isotopic exchange reaction renders possible the estimation of sorption rates.

  15. Teams explore water supplies in Latin America: Interest raised in isotope techniques

    International Nuclear Information System (INIS)

    Gonfiantini, R.

    1984-01-01

    Latin American countries are particularly interested in applying isotope techniques in hydrology and other fields of earth sciences. Ten research contracts already have been awarded under the IAEA's Co-ordinated Research Programme on the Application of Isotope Techniques in Hydrology in the Latin American Region. In July 1984, IAEA and UNESCO sponsored a regional seminar for Latin America on the use of isotope techniques in water resources management in Buenos Aires

  16. Research on isotope geology. Assessment of heat production potential of granitic rocks and development of geothermal exploration techniques using radioactive/stable isotopes and fission track 2

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Cheon; Chi, Se Jung [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of)

    1995-12-01

    Radioelements and heat production rates of granitic rocks and stable isotopes of groundwaters were analyzed to investigate the geothermal potential of Wolchulsan granite complex in the southern Yeongam area. Wolchulsan granite complex is composed mainly by Cretaceous pink alkali-feldspar granite and partly Jurassic biotite granite. The main target for the geothermal exploration is the alkali-feldspar granite that is known in general to be favorable geothermal reservoir(e.g., Shap granite in UK). To develop exploration techniques for geothermal anomalies, all geochemical data were compared to those from the Jeonju granite complex. Heat production rates(HPR) of the alkali-feldspar granite is 1.8 - 10.6 {mu}Wm{sup -3}. High radio-thermal anomalies were revealed from the central western and northern parts of the granite body. These are relatively higher than the Caledonian hot dry granites in the UK. The integrated assessment of Wolchulsan granite complex suggests potential of the Cretaceous alkali-feldspar granite as a geothermal targets. Groundwater geochemistry of the Yeongam area reflects simple evaporation process and higher oxidation environment. Stable isotope data of groundwaters are plotted on or close to the Meteoric Water Line(MWL). These isotopic data indicate a significant meteoric water dominance and do not show oxygen isotope fractionation between groundwater and wall rocks. In despite of high HPR values of the Yeongam alkali-feldspar granite, groundwater samples do not show the same geochemical properties as a thermal water in the Jeonju area. This reason can be well explained by the comparison with geological settings of the Jeonju area. The Yeongam alkali-feldspar granite does not possess any adjacent heat source rocks despite its high radio-thermal HPR. While the Jeonju granite batholith has later heat source intrusive and suitable deep fracture system for water circulation with sedimentary cap rocks. (Abstract Truncated)

  17. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    Science.gov (United States)

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  18. Stable isotope methods: The effect of gut contents on isotopic ratios of zooplankton

    Science.gov (United States)

    Hill, J. M.; McQuaid, C. D.

    2011-05-01

    In the past decade there has been an increased awareness of the potential for methodological bias resulting from multiple pre-analytical procedures in foodweb interpretations based on stable isotope techniques. In the case of small organisms, this includes the effect of gut contents on whole body signatures. Although gut contents may not reflect actual assimilation, their carbon and nitrogen values will be isotopically lighter than after the same material has been assimilated. The potential skewing of isotopic ratios in whole organism samples is especially important for aquatic environments as many studies involve trophic relationships among small zooplankton. This is particularly important in pelagic waters, where herbivorous zooplankton comprise small taxa. Hence this study investigated the effect of gut contents on the δ13C and δ15N ratios of three size classes of zooplankton (1.0-2.0, 2.0-4.0 and >4.0 mm) collected using bongo net tows in the tropical waters of the south-west Indian Ocean. Animals were collected at night, when they were likely to be feeding, sieved into size classes and separated into genera. We focused on Euphausia spp which dominated zooplankton biomass. Three treatment types were processed: bulk animals, bulk animals without guts and tail muscle from each size class at 10 bongo stations. The δ15N ratios were influenced by zooplankton size class, presumably reflecting ontogenetic changes in diet. ANOVA post hoc results and correlations in δ15N signatures among treatments suggest that gut contents may not affect overall nitrogen signatures of Euphausia spp., but that δ13C signatures may be significantly altered by their presence. Carbon interpretations however, were complicated by potential effects of variation in chitin, lipids and metabolism among tissues and the possibility of opportunistic omnivory. Consequently we advocate gut evacuation before sacrifice in euphausiids if specific tissue dissection is impractical and recommend

  19. Preliminary results of oxygen isotope ratio measurement with a particle-gamma coincidence method

    Energy Technology Data Exchange (ETDEWEB)

    Borysiuk, Maciek, E-mail: maciek.borysiuk@pixe.lth.se; Kristiansson, Per; Ros, Linus; Abdel, Nassem S.; Elfman, Mikael; Nilsson, Charlotta; Pallon, Jan

    2015-04-01

    The possibility to study variations in the oxygen isotopic ratio with photon tagged nuclear reaction analysis (pNRA) is evaluated in the current work. The experiment described in the article was performed at Lund Ion Beam Analysis Facility (LIBAF) with a 2 MeV deuteron beam. Isotopic fractionation of light elements such as carbon, oxygen and nitrogen is the basis of many analytical tools in hydrology, geology, paleobiology and paleogeology. IBA methods provide one possible tool for measurement of isotopic content. During this experimental run we focused on measurement of the oxygen isotopic ratio. The measurement of stable isotopes of oxygen has a number of applications; the particular one driving the current investigation belongs to the field of astrogeology and specifically evaluation of fossil extraterrestrial material. There are three stable isotopes of oxygen: {sup 16}O, {sup 17}O and {sup 18}O. We procured samples highly enriched with all three isotopes. Isotopes {sup 16}O and {sup 18}O were easily detected in the enriched samples, but no significant signal from {sup 17}O was detected in the same samples. The measured yield was too low to detect {sup 18}O in a sample with natural abundances of oxygen isotopes, at least in the current experimental setup, but the spectral line from the reaction with {sup 16}O was clearly visible.

  20. Method for separating the isotopes of a chemical element

    International Nuclear Information System (INIS)

    Devienne, F.M.

    1977-01-01

    A beam of positive or negative primary ions of at least one compound of a chemical element is accelerated in order to pass through collision boxes placed in series. As a result of inelastic collisions of the ions with the molecules of a neutral target gas within each collision box, a given percentage of primary ions is dissociated into at least two fragments, one of which is a secondary ion in the form of at least two isotopic species. The collision boxes are brought to a potential V 2 so as to trap preferentially one isotopic species which is condensed within each box. 15 claims, 4 figures

  1. A Graphite Isotope Ratio Method: A Primer on Estimating Plutonium Production in Graphite Moderated Reactors

    International Nuclear Information System (INIS)

    Gesh, Christopher J.

    2004-01-01

    The Graphite Isotope Ratio Method (GIRM) is a technique used to estimate the total plutonium production in a graphite-moderated reactor. The cumulative plutonium production in that reactor can be accurately determined by measuring neutron irradiation induced isotopic ratio changes in certain impurity elements within the graphite moderator. The method does not require detailed knowledge of a reactor's operating history, although that knowledge can decrease the uncertainty of the production estimate. The basic premise of the Graphite Isotope Ratio Method is that the fluence in non-fuel core components is directly related to the cumulative plutonium production in the nuclear fuel

  2. Application of helium isotopes in shallow groundwaters for geothermal energy exploration in the Upper Rhine Graben

    Energy Technology Data Exchange (ETDEWEB)

    Freundt, Florian

    2017-07-12

    The helium isotope system is an established tool in hydrology for identifying mantle fluids in deep aquifers. This study applies the helium tracer system for the first time in shallow, unconfined aquifers of the Upper Rhine Graben. The Graben is a part of the Cenozoic Rift system of Western and Central Europe, a continental rift zone with unusually high geothermal gradients, making it an ideal region of Germany for geothermal energy development. The aim of this study is to develop a suite of natural groundwater tracers able to achieve a cost and effort reduction in geothermal prospection. The {sup 3}He/{sup 4}He-ratio is therefore applied, as part of a multi-tracer approach including {sup 3}H, δ{sup 18}O, δ{sup 2}H, δ{sup 13}C, {sup 14}C and {sup 222}Rn, to identify and locate fault zones with suitable permeabilities for power plant operation. Three target areas along the graben were studied, each located on one of the main fault lines. A mantle-derived helium signature could be identified and separated from tritiogenic helium in a shallow aquifer in the north-west of the Graben. The mixing component of mantle-derived fluid in the shallow groundwater is calculated to reach up to 5%, based on the analysis of the {sup 3}He/{sup 4}He isotope system. The employed method proves that the local permeability of the fault zone is high. The origin of the locally occurring upwelling of salinated water can be redetermined by the data.

  3. COMBINING SOURCES IN STABLE ISOTOPE MIXING MODELS: ALTERNATIVE METHODS

    Science.gov (United States)

    Stable isotope mixing models are often used to quantify source contributions to a mixture. Examples include pollution source identification; trophic web studies; analysis of water sources for soils, plants, or water bodies; and many others. A common problem is having too many s...

  4. Solution of the isotopic depletion equation using decomposition method and analytical solution

    Energy Technology Data Exchange (ETDEWEB)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: fprata@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@lmp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  5. Solution of the isotopic depletion equation using decomposition method and analytical solution

    International Nuclear Information System (INIS)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S.

    2011-01-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  6. Interactive methods for exploring particle simulation data

    Energy Technology Data Exchange (ETDEWEB)

    Co, Christopher S.; Friedman, Alex; Grote, David P.; Vay, Jean-Luc; Bethel, E. Wes; Joy, Kenneth I.

    2004-05-01

    In this work, we visualize high-dimensional particle simulation data using a suite of scatter plot-based visualizations coupled with interactive selection tools. We use traditional 2D and 3D projection scatter plots as well as a novel oriented disk rendering style to convey various information about the data. Interactive selection tools allow physicists to manually classify ''interesting'' sets of particles that are highlighted across multiple, linked views of the data. The power of our application is the ability to correspond new visual representations of the simulation data with traditional, well understood visualizations. This approach supports the interactive exploration of the high-dimensional space while promoting discovery of new particle behavior.

  7. Uranium exploration methods used by NUCLEBRAS

    International Nuclear Information System (INIS)

    Santos, L.C.S. dos.

    1985-01-01

    The main methods used by geologists of NUCLEBRAS in uranium prospecting are presented and described. Severals geologic areas were evaluated based on geologic environments and short local surveys. The efficiency of methods were proved by the results. The steps for uranium prospecting carried out are: geological reconnaissances, aereal surveys, photogeological mappings, geochemical surveys, geological profiles, radiometric surveys, geological mappings, drillings and chemical analysis. (M.C.K.) [pt

  8. Assessment of methods for analyzing gaseous mixtures of hydrogen isotopes and helium

    International Nuclear Information System (INIS)

    Attalla, A.; Bishop, C.T.; Bohl, D.R.; Buxton, T.L.; Sprague, R.E.; Warner, D.K.

    1976-01-01

    Mass spectrographic methods have served well in the past to analyze gaseous mixtures of the hydrogen isotopes. Alternate methods of analyses are reviewed which offer wider ranges and variety of isotopic determinations. This report describes possible improvements of the mass spectrographic determinations, gas chromatography, anti-Stokes Raman spectroscopy, microwave-induced optical emission spectroscopy, and methods of measuring tritium using radiation detection devices. Precision, accuracy, limitations, and costs are included for some of the methods mentioned. Costs range from $70,000 for the anti-Stokes Raman spectroscopy equipment, which can determine hydrogen isotopes but not helium, to less than $10,000 for the gas chromatographic equipment, which can determine hydrogen isotopes and helium with precision and accuracy comparable to those of the mass spectrometer

  9. Assessing of distribution, mobility and bioavailability of exogenous Pb in agricultural soils using isotopic labeling method coupled with BCR approach

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhi-Yong, E-mail: zhyhuang@jmu.edu.cn [College of Bioengineering, Jimei University, Xiamen 361021 (China); Xie, Hong [College of Bioengineering, Jimei University, Xiamen 361021 (China); Shandong Vocational Animal Science and Veterinary College, Weifang 261061 (China); Cao, Ying-Lan [College of Bioengineering, Jimei University, Xiamen 361021 (China); Cai, Chao [Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021 (China); Zhang, Zhi [College of Bioengineering, Jimei University, Xiamen 361021 (China)

    2014-02-15

    Highlights: • Large amounts of exogenous Pb were found to distribute in reducible fractions. • Very few of exogenous Pb were found to distribute in acid-extractable fractions. • More than 60% of exogenous Pb in rhizosphere soils lost after planting. • Isotopic labeling method and SEP enable to explore Pb bioavailability in soil. -- Abstract: The contamination of Pb in agricultural soils is one of the most important ecological problems, which potentially results in serious health risk on human health through food chain. Hence, the fate of exogenous Pb contaminated in agricultural soils is needed to be deeply explored. By spiking soils with the stable enriched isotopes of {sup 206}Pb, the contamination of exogenous Pb{sup 2+} ions in three agricultural soils sampled from the estuary areas of Jiulong River, China was simulated in the present study, and the distribution, mobility and bioavailability of exogenous Pb in the soils were investigated using the isotopic labeling method coupled with a four-stage BCR (European Community Bureau of Reference) sequential extraction procedure. Results showed that about 60–85% of exogenous Pb was found to distribute in reducible fractions, while the exogenous Pb in acid-extractable fractions was less than 1.0%. After planting, the amounts of exogenous Pb presenting in acid-extractable, reducible and oxidizable fractions in rhizospheric soils decreased by 60–66%, in which partial exogenous Pb was assimilated by plants while most of the metal might transfer downward due to daily watering and applying fertilizer. The results show that the isotopic labeling technique coupled with sequential extraction procedures enables us to explore the distribution, mobility and bioavailability of exogenous Pb contaminated in soils, which may be useful for the further soil remediation.

  10. Assessing of distribution, mobility and bioavailability of exogenous Pb in agricultural soils using isotopic labeling method coupled with BCR approach

    International Nuclear Information System (INIS)

    Huang, Zhi-Yong; Xie, Hong; Cao, Ying-Lan; Cai, Chao; Zhang, Zhi

    2014-01-01

    Highlights: • Large amounts of exogenous Pb were found to distribute in reducible fractions. • Very few of exogenous Pb were found to distribute in acid-extractable fractions. • More than 60% of exogenous Pb in rhizosphere soils lost after planting. • Isotopic labeling method and SEP enable to explore Pb bioavailability in soil. -- Abstract: The contamination of Pb in agricultural soils is one of the most important ecological problems, which potentially results in serious health risk on human health through food chain. Hence, the fate of exogenous Pb contaminated in agricultural soils is needed to be deeply explored. By spiking soils with the stable enriched isotopes of 206 Pb, the contamination of exogenous Pb 2+ ions in three agricultural soils sampled from the estuary areas of Jiulong River, China was simulated in the present study, and the distribution, mobility and bioavailability of exogenous Pb in the soils were investigated using the isotopic labeling method coupled with a four-stage BCR (European Community Bureau of Reference) sequential extraction procedure. Results showed that about 60–85% of exogenous Pb was found to distribute in reducible fractions, while the exogenous Pb in acid-extractable fractions was less than 1.0%. After planting, the amounts of exogenous Pb presenting in acid-extractable, reducible and oxidizable fractions in rhizospheric soils decreased by 60–66%, in which partial exogenous Pb was assimilated by plants while most of the metal might transfer downward due to daily watering and applying fertilizer. The results show that the isotopic labeling technique coupled with sequential extraction procedures enables us to explore the distribution, mobility and bioavailability of exogenous Pb contaminated in soils, which may be useful for the further soil remediation

  11. Adsorption methods for hydrogen isotope storage on zeolitic sieves

    International Nuclear Information System (INIS)

    Cristescu, Ioana; Cristescu, Ion; Vasut, F.; Brad, S.; Lazar, A.

    2001-01-01

    For hydrogen isotope separation, adsorption molecular sieves and active carbon were used. Adsorption process proceeds at liquid nitrogen and liquid hydrogen temperatures. Commercial zeolites have the same proprieties with natural zeolites, but they have a regular pore structure. They also have affinity for molecules of different size with defined shapes. Experimental results obtained at liquid nitrogen temperature (77.4 K) and liquid hydrogen revealed the efficient behaviour of the active carbon and zeolitic sieves for hydrogen isotopes temporary storage. We study adsorption of the synthetic zeolites in a wide range of temperatures and pressures and we used the molecular sieves 4A, 5A and active carbon. The 4A and 5A zeolites have a tridimensional structure with 11.4 A diameter. When the hydration water is eliminated, the material keeps a porous structure. The porous volume represents 45% from the zeolite mass for 4A and 5A sieves. The activation temperature of the zeolite and the carbon is very important for obtaining a high adsorption capacity. If the temperature used for activation is low, the structural water will be not eliminated and the adsorption capacity will be low. The excessive temperature will destroy the porous structure. The adsorption capacity for the hydrogen isotopes was calculated with the relation: A = V ads /m (cm 3 /g). The adsorption capacity and efficiency for the adsorbent materials, are given. Physical adsorption process of the hydrogen isotopes was carried out at liquid nitrogen temperature. The flux gas used in the adsorption system is composed of dry deuterium and protium. This mixture is cooled in liquid nitrogen and then is passed to the adsorbent getter at the same temperature (77.4 K). The gas flux in the adsorbent getter is 5 and 72 l/h (which correspond to 0.008 and 0.134 discharge velocity, respectively). (authors)

  12. Stable isotopes and elasmobranchs: tissue types, methods, applications and assumptions.

    Science.gov (United States)

    Hussey, N E; MacNeil, M A; Olin, J A; McMeans, B C; Kinney, M J; Chapman, D D; Fisk, A T

    2012-04-01

    Stable-isotope analysis (SIA) can act as a powerful ecological tracer with which to examine diet, trophic position and movement, as well as more complex questions pertaining to community dynamics and feeding strategies or behaviour among aquatic organisms. With major advances in the understanding of the methodological approaches and assumptions of SIA through dedicated experimental work in the broader literature coupled with the inherent difficulty of studying typically large, highly mobile marine predators, SIA is increasingly being used to investigate the ecology of elasmobranchs (sharks, skates and rays). Here, the current state of SIA in elasmobranchs is reviewed, focusing on available tissues for analysis, methodological issues relating to the effects of lipid extraction and urea, the experimental dynamics of isotopic incorporation, diet-tissue discrimination factors, estimating trophic position, diet and mixing models and individual specialization and niche-width analyses. These areas are discussed in terms of assumptions made when applying SIA to the study of elasmobranch ecology and the requirement that investigators standardize analytical approaches. Recommendations are made for future SIA experimental work that would improve understanding of stable-isotope dynamics and advance their application in the study of sharks, skates and rays. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  13. Method of concentrating and separating lithium isotopes by laser

    International Nuclear Information System (INIS)

    Yamashita, Mikio; Kashiwagi, Hiroshi.

    1976-01-01

    Purpose: To eliminate the need for repeating separating operation in many stages and permit concentrated lithium of high purity to be obtained in a short period of time. Constitution: Lithium atom vapor is irradiated by a laser of wavelengths resonant to 6 Li or 7 Li absorption spectra present in the neighborhood of 6,707.84 A or 3,232.61 A (chromatic laser being used for oscillation in the neighborhood of 6,707.84 A and ultraviolet laser used for oscillation in the neighborhood of 6,707.84 A) for selectively exciting 6 Li or 7 Li alone. Then, ionization is brought about by using other types of lasers (ultraviolet Ar ion laser being used as the former wavelength laser and visible Ar ion laser as the latter wavelength laser), and only the ionized isotopes are passed through a mass filter and collected by an ion collector, thereby effecting separation of the ionized isotopes from the non-ionized neutral isotopes and their concentration. (Aizawa, K.)

  14. Bacterial diversity exploration in hydrocarbon polluted soil: metabolic potential and degrader community evolution revealed by isotope labeling

    International Nuclear Information System (INIS)

    Martin, F.

    2011-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous compounds produced by incomplete combustion of organic matter. They are a source of environmental pollution, especially associated to oil product exploitation, and represent a threat for living organisms including human beings because of their toxicity. Many bacteria capable of degrading PAHs have been isolated and studied. However, since less than 5% of soil bacteria can be cultivated in the laboratory, bacterial species able to degrade PAHs in situ have been poorly studied. The first goal of this study was to identify bacteria that degrade PAHs in soil using culture-independent molecular methods. To this end, a strategy known a stable isotope probing has been implemented based on the use of phenanthrene, a three rings PAH, in which the natural isotope of carbon was replaced by 13 C. This molecule has been introduced as a tracer in microcosms containing soil from a constructed wetlands collecting contaminated water from highway runoff. Bacteria having incorporated the 13 C were then identified by 16 S rRNA gene sequence analysis after PCR amplification from labeled genomic DNA extracted from soil. The results show that so far little studied Betaproteobacteria, belonging to the genera Acidovorax, Rhodoferax, Hydrogenophaga and Thiobacillus, as well as Rhodocyclaceae, were the key players in phenanthrene degradation. Predominance of Betaproteobacteries was established thanks to quantitative PCR measurements. A dynamic analysis of bacterial diversity also showed that the community structure of degraders depended on phenanthrene bioavailability. In addition, the phylogenetic diversity of ring-hydroxylating di-oxygenases, enzymes involved in the first step of PAH degradation, has been explored. We detected new sequences, mostly related to di-oxygenases from Sphingomonadales and Burkholderiales. For the first time, we were able to associate a catalytic activity for oxidation of PAHs to partial gene sequences

  15. Inverse methods for estimating primary input signals from time-averaged isotope profiles

    Science.gov (United States)

    Passey, Benjamin H.; Cerling, Thure E.; Schuster, Gerard T.; Robinson, Todd F.; Roeder, Beverly L.; Krueger, Stephen K.

    2005-08-01

    Mammalian teeth are invaluable archives of ancient seasonality because they record along their growth axes an isotopic record of temporal change in environment, plant diet, and animal behavior. A major problem with the intra-tooth method is that intra-tooth isotope profiles can be extremely time-averaged compared to the actual pattern of isotopic variation experienced by the animal during tooth formation. This time-averaging is a result of the temporal and spatial characteristics of amelogenesis (tooth enamel formation), and also results from laboratory sampling. This paper develops and evaluates an inverse method for reconstructing original input signals from time-averaged intra-tooth isotope profiles. The method requires that the temporal and spatial patterns of amelogenesis are known for the specific tooth and uses a minimum length solution of the linear system Am = d, where d is the measured isotopic profile, A is a matrix describing temporal and spatial averaging during amelogenesis and sampling, and m is the input vector that is sought. Accuracy is dependent on several factors, including the total measurement error and the isotopic structure of the measured profile. The method is shown to accurately reconstruct known input signals for synthetic tooth enamel profiles and the known input signal for a rabbit that underwent controlled dietary changes. Application to carbon isotope profiles of modern hippopotamus canines reveals detailed dietary histories that are not apparent from the measured data alone. Inverse methods show promise as an effective means of dealing with the time-averaging problem in studies of intra-tooth isotopic variation.

  16. Isotope methods in water resources assessment and environmental management

    International Nuclear Information System (INIS)

    Araguas-Araguas, L.

    1996-01-01

    Availability of water and protection of water resources have become top environmental issues in many countries. Governments are forced to issue strict guidelines to protect the environment and create agencies to pursue these aspects as well as enforce such regulations. The supply of good-quality water from rivers and lakes is becoming a costly and complex problem for many institutes responsible for water supply. Because of the high pollution levels in surface waters, ground water is the main source of drinking water in many countries. It is estimated that 1.5 billion people world-wide depend on it for drinking water. Since ground water cannot be directly measured, and despite its importance for drinking purposes there is not enough public concern about its protection. In other cases, it is found that the exploited ground water is not a renewable resource. In many countries in arid and semi-arid regions, fossil ground water is being tapped for extensive agricultural development, but such extraction depletes the reserves, in the same way as an oil reservoir. The availability of correct information, before decisions are taken will lead to improved management of water resources, distributing the available resources for different uses according to their quality, and ultimately, to manage the resource. Nuclear science has developed a series of methodologies based on the use of naturally-occurring isotopes and artificial tracers to study the processes involved in the occurrence and circulation of water. The discipline called 'Isotope Hydrology' provides a deep insight into many parts of the water cycle; from the evaporation over the ocean or the continents, to the formation of surface runoff and ground water and in the discharge of aquifer systems into the ocean. Isotope hydrology, as a scientific and applied discipline in earth sciences, was created during the late 1950s and early 1960s, beyond the classical hydrological science. In these early stages, new methodologies

  17. Method of deuterium isotope separation using ethylene and ethylene dichloride

    International Nuclear Information System (INIS)

    Benson, S.W.

    1982-01-01

    Compounds enriched in deuterium may be obtained from ethylene, vinyl chloride, 1,2-dichloroethane, or propylene by laser isotope separation. Normal molecules of these organic compounds are exposed to infrared laser radiation of a suitable wavelength. Substantially all of the deuterium-containing molecules exposed to the laser can be selectively dissociated and the deuterium-containing products separated from the starting material and other reaction products. The deuterium-containing molecules can be burned to form water with an enriched deuterium content, or pyrolized to form hydrogen gas enriched in deuterium

  18. The outline of the processes for lithium isotope separation by ion exchange method

    International Nuclear Information System (INIS)

    Fujine, Sachio; Saito, Keiichiro; Naruse, Yuji; Shiba, Koreyuki; Kosuge, Masao; Itoi, Toshiaki; Kitsukawa, Tomohiko.

    1981-10-01

    A plant of lithium isotope separation by displacement chromatography is preliminary designed. The construction expenses of a 100 kg 7 Li/year plant and the unit cost of separation are estimated on the basis of the data taken from the literature, and the feasibility is studied. Experimental equipment of continuous displacement chromatography is set up and is tested with the stable automatic operation. These results indicate that the ion exchange method is promising for industrial lithium isotope separation. (author)

  19. Ground-state properties of axially deformed Sr isotopes in Skyrme-Hartree-Fock-Bogolyubov method

    International Nuclear Information System (INIS)

    Yilmaz, A.H.; Bayram, T.; Demirci, M.; Engin, B.; Bayram, T.

    2010-01-01

    Binding energies, the mean-square nuclear radii, neutron radii, quadrupole moments and deformation parameters to axially deformed Strontium isotopes were evaluated using Hartree-Fock-Bogolyubov method. Shape coexistence was also discussed. The results were compared with experimental data and some estimates obtained within some nuclear models. The calculations were performed for SIy4 set of Skyrme forces and for wide range of the neutron numbers of Sr isotopes

  20. Graphite Isotope Ratio Method Development Report: Irradiation Test Demonstration of Uranium as a Low Fluence Indicator

    International Nuclear Information System (INIS)

    Reid, B.D.; Gerlach, D.C.; Love, E.F.; McNeece, J.P.; Livingston, J.V.; Greenwood, L.R.; Petersen, S.L.; Morgan, W.C.

    1999-01-01

    This report describes an irradiation test designed to investigate the suitability of uranium as a graphite isotope ratio method (GIRM) low fluence indicator. GIRM is a demonstrated concept that gives a graphite-moderated reactor's lifetime production based on measuring changes in the isotopic ratio of elements known to exist in trace quantities within reactor-grade graphite. Appendix I of this report provides a tutorial on the GIRM concept

  1. Assessing of distribution, mobility and bioavailability of exogenous Pb in agricultural soils using isotopic labeling method coupled with BCR approach.

    Science.gov (United States)

    Huang, Zhi-Yong; Xie, Hong; Cao, Ying-Lan; Cai, Chao; Zhang, Zhi

    2014-02-15

    The contamination of Pb in agricultural soils is one of the most important ecological problems, which potentially results in serious health risk on human health through food chain. Hence, the fate of exogenous Pb contaminated in agricultural soils is needed to be deeply explored. By spiking soils with the stable enriched isotopes of (206)Pb, the contamination of exogenous Pb(2+) ions in three agricultural soils sampled from the estuary areas of Jiulong River, China was simulated in the present study, and the distribution, mobility and bioavailability of exogenous Pb in the soils were investigated using the isotopic labeling method coupled with a four-stage BCR (European Community Bureau of Reference) sequential extraction procedure. Results showed that about 60-85% of exogenous Pb was found to distribute in reducible fractions, while the exogenous Pb in acid-extractable fractions was less than 1.0%. After planting, the amounts of exogenous Pb presenting in acid-extractable, reducible and oxidizable fractions in rhizospheric soils decreased by 60-66%, in which partial exogenous Pb was assimilated by plants while most of the metal might transfer downward due to daily watering and applying fertilizer. The results show that the isotopic labeling technique coupled with sequential extraction procedures enables us to explore the distribution, mobility and bioavailability of exogenous Pb contaminated in soils, which may be useful for the further soil remediation. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Doubly labeled water method: in vivo oxygen and hydrogen isotope fractionation

    International Nuclear Information System (INIS)

    Schoeller, D.A.; Leitch, C.A.; Brown, C.

    1986-01-01

    The accuracy and precision of the doubly labeled water method for measuring energy expenditure are influenced by isotope fractionation during evaporative water loss and CO 2 excretion. To characterize in vivo isotope fractionation, we collected and isotopically analyzed physiological fluids and gases. Breath and transcutaneous water vapor were isotopically fractionated. The degree of fractionation indicated that the former was fractionated under equilibrium control at 37 0 C, and the latter was kinetically fractionated. Sweat and urine were unfractionated. By use of isotopic balance models, the fraction of water lost via fractionating routes was estimated from the isotopic abundances of body water, local drinking water, and dietary solids. Fractionated water loss averaged 23% (SD = 10%) of water turnover, which agreed with our previous estimates based on metabolic rate, but there was a systematic difference between the results based on O 2 and hydrogen. Corrections for isotopic fractionation of water lost in breath and (nonsweat) transcutaneous loss should be made when using labeled water to measure water turnover or CO 2 production

  3. Innovative method for ultra-sensitive measurement of krypton isotopes

    International Nuclear Information System (INIS)

    Lavielle, B.; Gilabert, E.; Thomas, B.; Rebeix, R.; Canchel, G.; Moulin, C.; Topin, S.; Pointurier, F.

    2015-01-01

    Kr 81 (T 1/2 = 2.29*10 5 y), that is produced in the atmosphere by cosmic rays and Kr 85 (T 1/2 = 10.77 y), that is produced in the fission of nuclear fuels, are considered as the right chronometer elements for the dating of underground waters, polar ice, of for tracking civil and military nuclear activities. The use of Kr 81 and Kr 85 implies the development of extracting lines and detection devices with so high accuracy that only a few thousands of krypton atoms can be detected. The approach developed aims at detecting Kr 81 and Kr 85 in 1 liter of air and 20 liters of water. 3 steps are necessary. The first step consists in separating and purifying the krypton. The extraction of gases from water is made by helium bubbling. Chemically active gases like N 2 , CO 2 , CH 4 and O 2 are eliminated by chemical traps while Ar si separated by cryogenics. The second step involves a double focus mass spectrometer designed to perform an important enrichment in Kr 81 and Kr 85 . The last step is the high-accuracy measurement of krypton isotopes performed with the new tool named FAKIR (Facility for Analyzing Krypton Isotopic Ratios) that is based on UV laser ionization and on the mass-discrimination of the ions through their time of flight

  4. Novel methods for estimating 3D distributions of radioactive isotopes in materials

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Y., E-mail: y.iwamoto0805@ruri.waseda.jp [Research Institute for Science and Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Kataoka, J.; Kishimoto, A.; Nishiyama, T.; Taya, T.; Okochi, H.; Ogata, H. [Research Institute for Science and Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Yamamoto, S. [Nagoya University Graduate School of Medicine, 1-1-20, Daikominami, Higashi-ku, Nagoya-shi, Aichi 461-8673 (Japan)

    2016-09-21

    In recent years, various gamma-ray visualization techniques, or gamma cameras, have been proposed. These techniques are extremely effective for identifying “hot spots” or regions where radioactive isotopes are accumulated. Examples of such would be nuclear-disaster-affected areas such as Fukushima or the vicinity of nuclear reactors. However, the images acquired with a gamma camera do not include distance information between radioactive isotopes and the camera, and hence are “degenerated” in the direction of the isotopes. Moreover, depth information in the images is lost when the isotopes are embedded in materials, such as water, sand, and concrete. Here, we propose two methods of obtaining depth information of radioactive isotopes embedded in materials by comparing (1) their spectra and (2) images of incident gamma rays scattered by the materials and direct gamma rays. In the first method, the spectra of radioactive isotopes and the ratios of scattered to direct gamma rays are obtained. We verify experimentally that the ratio increases with increasing depth, as predicted by simulations. Although the method using energy spectra has been studied for a long time, an advantage of our method is the use of low-energy (50–150 keV) photons as scattered gamma rays. In the second method, the spatial extent of images obtained for direct and scattered gamma rays is compared. By performing detailed Monte Carlo simulations using Geant4, we verify that the spatial extent of the position where gamma rays are scattered increases with increasing depth. To demonstrate this, we are developing various gamma cameras to compare low-energy (scattered) gamma-ray images with fully photo-absorbed gamma-ray images. We also demonstrate that the 3D reconstruction of isotopes/hotspots is possible with our proposed methods. These methods have potential applications in the medical fields, and in severe environments such as the nuclear-disaster-affected areas in Fukushima.

  5. Novel methods for estimating 3D distributions of radioactive isotopes in materials

    Science.gov (United States)

    Iwamoto, Y.; Kataoka, J.; Kishimoto, A.; Nishiyama, T.; Taya, T.; Okochi, H.; Ogata, H.; Yamamoto, S.

    2016-09-01

    In recent years, various gamma-ray visualization techniques, or gamma cameras, have been proposed. These techniques are extremely effective for identifying "hot spots" or regions where radioactive isotopes are accumulated. Examples of such would be nuclear-disaster-affected areas such as Fukushima or the vicinity of nuclear reactors. However, the images acquired with a gamma camera do not include distance information between radioactive isotopes and the camera, and hence are "degenerated" in the direction of the isotopes. Moreover, depth information in the images is lost when the isotopes are embedded in materials, such as water, sand, and concrete. Here, we propose two methods of obtaining depth information of radioactive isotopes embedded in materials by comparing (1) their spectra and (2) images of incident gamma rays scattered by the materials and direct gamma rays. In the first method, the spectra of radioactive isotopes and the ratios of scattered to direct gamma rays are obtained. We verify experimentally that the ratio increases with increasing depth, as predicted by simulations. Although the method using energy spectra has been studied for a long time, an advantage of our method is the use of low-energy (50-150 keV) photons as scattered gamma rays. In the second method, the spatial extent of images obtained for direct and scattered gamma rays is compared. By performing detailed Monte Carlo simulations using Geant4, we verify that the spatial extent of the position where gamma rays are scattered increases with increasing depth. To demonstrate this, we are developing various gamma cameras to compare low-energy (scattered) gamma-ray images with fully photo-absorbed gamma-ray images. We also demonstrate that the 3D reconstruction of isotopes/hotspots is possible with our proposed methods. These methods have potential applications in the medical fields, and in severe environments such as the nuclear-disaster-affected areas in Fukushima.

  6. Development of a new method for hydrogen isotope analysis of trace hydrocarbons in natural gas samples

    Directory of Open Access Journals (Sweden)

    Xibin Wang

    2016-12-01

    Full Text Available A new method had been developed for the analysis of hydrogen isotopic composition of trace hydrocarbons in natural gas samples by using solid phase microextraction (SPME combined with gas chromatography-isotope ratio mass spectrometry (GC/IRMS. In this study, the SPME technique had been initially introduced to achieve the enrichment of trace content of hydrocarbons with low abundance and coupled to GC/IRMS for hydrogen isotopic analysis. The main parameters, including the equilibration time, extraction temperature, and the fiber type, were systematically optimized. The results not only demonstrated that high extraction yield was true but also shows that the hydrogen isotopic fractionation was not observed during the extraction process, when the SPME device fitted with polydimethylsiloxane/divinylbenzene/carbon molecular sieve (PDMS/DVB/CAR fiber. The applications of SPME-GC/IRMS method were evaluated by using natural gas samples collected from different sedimentary basins; the standard deviation (SD was better than 4‰ for reproducible measurements; and also, the hydrogen isotope values from C1 to C9 can be obtained with satisfying repeatability. The SPME-GC/IRMS method fitted with PDMS/DVB/CAR fiber is well suited for the preconcentration of trace hydrocarbons, and provides a reliable hydrogen isotopic analysis for trace hydrocarbons in natural gas samples.

  7. Analysis method for beta-gamma coincidence spectra from radio-xenon isotopes

    International Nuclear Information System (INIS)

    Yang Wenjing; Yin Jingpeng; Huang Xiongliang; Cheng Zhiwei; Shen Maoquan; Zhang Yang

    2012-01-01

    Radio-xenon isotopes monitoring is one important method for the verification of CTBT, what includes the measurement methods of HPGe γ spectrometer and β-γ coincidence. The article describes the analytic flowchart and method of three-dimensional beta-gamma coincidence spectra from β-γ systems, and analyses in detail the principles and methods of the regions of interest of coincidence spectra and subtracting the interference, finally gives the formula of radioactivity of Xenon isotopes and minimum detectable concentrations. Studying on the principles of three-dimensional beta-gamma coincidence spectra, which can supply the foundation for designing the software of β-γ coincidence systems. (authors)

  8. Assessment of phyto-available cadmium in soils using isotopic methods

    International Nuclear Information System (INIS)

    Gerard, Emilie

    2000-01-01

    The quantification of phyto-available Cd in soils is necessary to determine the transfer risk of this toxic element to plants. Isotopic methods (isotopic exchange kinetics (IEK), isotopic dilution) were used to characterize the phyto-available Cd and, practically, to select chemical methods for determining available Cd to plants. Rye grass (Lolium perenne L.), lettuce (Lactuca saliva L.) and the Cd hyper-accumulator Thlaspi caerulescens J. Presl. and C. Presl. were selected as test plants because of their wide range of Cd uptake ability. The chosen soils had different pH and displayed a Cd-contamination gradient due the atmospheric deposition of industrial particles. In the acidic soil, plants had access to the same metal pool, the one that was isotopically exchangeable with Cd 2+ . This was also the case for rye grass on the calcareous Soils but there, lettuce and T. caerulescens accessed a bigger and non-isotopically exchangeable pool that accounted for 16 to 52 % of the plant available Cd. Most of the Cd was isotopically exchangeable in a short time in the acidic soil (87 % within 21 days). In the calcareous soils two pools were identified, one pool was isotopically exchangeable in a very short time, and the other one Was not exchangeable after 21 days (21 to 10 % of the total Cd). Actually, the quantities of labile cd in the industrial particles which had contaminated these soils were very small. IEK methods and the measurement of the isotopic composition of Cd 2+ in soil solutions allowed for the estimation of the phyto-available Cd in soils, but cannot he commonly used. Most of the chemical extractants studied such as CaCl 2 or DTP A are suitable to assess the phyto-available Cd. However, on calcareous soils, the choice of extractant needs to sometimes be modified in relation to the rate of Cd plant absorption. (author) [fr

  9. A new cascade method for studying isotope effect in chemical exchange system without valance change

    International Nuclear Information System (INIS)

    Wen Xiaoning; Luo Wenzong

    1987-01-01

    A new cascade method for studying isotope effect in chemical exchange system without valance change is developed and described. This method is simple to use and consumes less extractant as compared with the commonly used Woodward method. It is also convenient for unstable systems

  10. On the Use of Biomineral Oxygen Isotope Data to Identify Human Migrants in the Archaeological Record: Intra-Sample Variation, Statistical Methods and Geographical Considerations.

    Directory of Open Access Journals (Sweden)

    Emma Lightfoot

    Full Text Available Oxygen isotope analysis of archaeological skeletal remains is an increasingly popular tool to study past human migrations. It is based on the assumption that human body chemistry preserves the δ18O of precipitation in such a way as to be a useful technique for identifying migrants and, potentially, their homelands. In this study, the first such global survey, we draw on published human tooth enamel and bone bioapatite data to explore the validity of using oxygen isotope analyses to identify migrants in the archaeological record. We use human δ18O results to show that there are large variations in human oxygen isotope values within a population sample. This may relate to physiological factors influencing the preservation of the primary isotope signal, or due to human activities (such as brewing, boiling, stewing, differential access to water sources and so on causing variation in ingested water and food isotope values. We compare the number of outliers identified using various statistical methods. We determine that the most appropriate method for identifying migrants is dependent on the data but is likely to be the IQR or median absolute deviation from the median under most archaeological circumstances. Finally, through a spatial assessment of the dataset, we show that the degree of overlap in human isotope values from different locations across Europe is such that identifying individuals' homelands on the basis of oxygen isotope analysis alone is not possible for the regions analysed to date. Oxygen isotope analysis is a valid method for identifying first-generation migrants from an archaeological site when used appropriately, however it is difficult to identify migrants using statistical methods for a sample size of less than c. 25 individuals. In the absence of local previous analyses, each sample should be treated as an individual dataset and statistical techniques can be used to identify migrants, but in most cases pinpointing a specific

  11. A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    Science.gov (United States)

    Bonin, Alice; Tsilanizara, Aimé

    2017-06-01

    Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly contribute to the dose build-up. This paper presents a new method (Isotopes Inventory Reconstruction-IIR) estimating the concentration of the minor isotopes in the irradiated material at the beginning of the cooling period. The method requires the solution of the inverse problem describing the irradiated material's decay. In a mixture of an irradiated uranium-plutonium oxide shielded by a set-up made of stainless-steel, porous polyethylene plaster and lead methyl methacrylate, the comparison between different methods proves that the IIR-method allows better assessment of the dose than other approximate methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. A Compositional Sweep-Line State Space Exploration Method

    DEFF Research Database (Denmark)

    Kristensen, Lars Michael; Mailund, Thomas

    2002-01-01

    State space exploration is a main approach to verification of finite-state systems. The sweep-line method exploits a certain kind of progress present in many systems to reduce peak memory usage during state space exploration. We present a new sweep-line algorithm for a compositional setting where...

  13. Using stable isotopes to monitor forms of sulfur during desulfurization processes: A quick screening method

    Science.gov (United States)

    Liu, Chao-Li; Hackley, Keith C.; Coleman, D.D.; Kruse, C.W.

    1987-01-01

    A method using stable isotope ratio analysis to monitor the reactivity of sulfur forms in coal during thermal and chemical desulfurization processes has been developed at the Illinois State Geological Survey. The method is based upon the fact that a significant difference exists in some coals between the 34S/32S ratios of the pyritic and organic sulfur. A screening method for determining the suitability of coal samples for use in isotope ratio analysis is described. Making these special coals available from coal sample programs would assist research groups in sorting out the complex sulfur chemistry which accompanies thermal and chemical processing of high sulfur coals. ?? 1987.

  14. Testing sequential extraction methods for the analysis of multiple stable isotope systems from a bone sample

    Science.gov (United States)

    Sahlstedt, Elina; Arppe, Laura

    2017-04-01

    Stable isotope composition of bones, analysed either from the mineral phase (hydroxyapatite) or from the organic phase (mainly collagen) carry important climatological and ecological information and are therefore widely used in paleontological and archaeological research. For the analysis of the stable isotope compositions, both of the phases, hydroxyapatite and collagen, have their more or less well established separation and analytical techniques. Recent development in IRMS and wet chemical extraction methods have facilitated the analysis of very small bone fractions (500 μg or less starting material) for PO43-O isotope composition. However, the uniqueness and (pre-) historical value of each archaeological and paleontological finding lead to preciously little material available for stable isotope analyses, encouraging further development of microanalytical methods for the use of stable isotope analyses. Here we present the first results in developing extraction methods for combining collagen C- and N-isotope analyses to PO43-O-isotope analyses from a single bone sample fraction. We tested sequential extraction starting with dilute acid demineralization and collection of both collagen and PO43-fractions, followed by further purification step by H2O2 (PO43-fraction). First results show that bone sample separates as small as 2 mg may be analysed for their δ15N, δ13C and δ18OPO4 values. The method may be incorporated in detailed investigation of sequentially developing skeletal material such as teeth, potentially allowing for the investigation of interannual variability in climatological/environmental signals or investigation of the early life history of an individual.

  15. Design study of fuel circulating system using Pd alloy membrane isotope separation method

    International Nuclear Information System (INIS)

    Naito, T.; Yamada, T.; Aizawa, T.; Kasahara, T.; Yamanaka, T.

    1981-01-01

    It is expected that the method of permeating through Pd-alloy membrances is effective for isotope separation and the refining of fuel gas. In this paper, the design study of the Fuel Circulating System (FCS) using Pb-alloy membranes is described. The study is mainly focused on the main vacuum, fuel gas refining, isotope separating, and tritium containment systems. In the fuel gas refining system, impurities are effectively removed by using Pd-alloy membranes. For the isotope separation system, the diffusion method through Pd-alloy membranes was adopted. From the standpoint of the safety and economy, a three-stage tritium containment system was adopted to control tritium release to the environment as low as possible. The principal conclusion drawn from the design study was as follows. In the FCS, while cryogenic distillation method appears to be practicable, Pd-alloy membrane method is attractive for isotope separation and the refining of fuel gas. For a large amount of tritium inventory, handling and control technologies should be completed by the experimental evaluation and development of the components and materials used for the FCS. A three-stage containment system was adopted to control tritium release to environment as low as possible. Consideration to prevent tritium escape will be necessary for fuel gas refiners and isotope separators. (Kato, T.)

  16. Studying of isotope structure of uranium by alpha-spectrometric method

    International Nuclear Information System (INIS)

    Sattarov, G.S.; Muzafarov, A.M.; Petukhov, O.F.; Petrenko, V.Z.

    2004-01-01

    Full text: The knowledge of isotope structure of uranium in waters, in minerals and in finished goods gives the helpful information on the radiation and nuclear-physical processes occurring in natural environments. Besides, customers put a question before uranium producing enterprises on the control of limiting concentration of an isotope 234 U in finished goods (uranium protoxide-oxide). For these reasons studying and development of techniques of definition of isotope structure of uranium is an actual task. In this connection for researches alpha - spectrometers 'PROGRESS-ALPHA' produced by R and D 'DOZE' Russia and firms 'Canberra' the USA were used. The isotope structure of uranium ( 234 U, 235 U, 238 U) was determined on a known ratio 234 U/ 238 U, which is equal to 53,41micrograms/gram. Identification of isotopes carried out by 4198 keV ( 235 U), 4395 keV ( 234 U) and 4773 keV ( 238 U). The technique of radiochemical preparation of samples to the analysis included: clearing of organic chemistry and preventing natural isotopes; drawing by a method electrolytic sedimentation on a metal substrate (d=24mm) an active stain, the area 4,5 cm 2 , with isotropy distribution of ions 234 U, 235 U, 238 U. As standards, the international and All-Russian standards with known contents 234 U were used. The isotope structure of uranium in uranium protoxide-oxide, chemical concentrates, technological solutions is determined. Infringements of isotope balance 234 U/ 238 U on separate sites of fulfilled uranium deposits and in technological products are found out

  17. Comparison of different methods of determining plutonium content and isotopic composition

    International Nuclear Information System (INIS)

    Dowell, M.R.W.

    1985-05-01

    At Rockwell Hanford Operations, several different methods are used to determine plutonium content and isotopic composition. These include alpha particle energy analysis, calorimetry/gamma-ray analysis, mass spectrometry, and low energy ray assay. Each is used in a process control environment and has its advantages and disadvantages in terms of sample matrix, sample preparation, concentration, error ranges, detection limits, and turn around time. Of the methods discussed, special attention is paid to the Plutonium Isotopics Solution Counter, a low energy gamma ray assay system designed to provide plutonium and americium content and isotopic composition of Pu-238 through Pu-241 and Am-241. It is qualitatively and quantitatively compared to the other methods. A brief description of sample types which the Solution Counter analyzes is presented. 4 refs., 4 tabs

  18. Comparison of different methods of determining plutonium content and isotopic composition

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    At Rockwell Hanford Operations, several different methods are used to determine plutonium content and isotopic composition. These include alpha particle energy analysis, calorimetry/gamma-ray analysis, mass spectrometry, and low energy gamma-ray assay. Each is used in a process control environment and has its advantages and disadvantages in terms of sample matrix, sample preparation, concentration, error ranges, detection limits, and turn around time. Of the methods discussed, special attention is paid to the Plutonium Isotopics Solution Counter, a low energy gamma-ray assay system designed to provide plutonium and americium content and isotopic composition of Pu-238 through Pu-241 and Am-241. It is qualitatively and quantitatively compared to the other methods. A brief description of sample types which the Solution Counter analyzes is presented

  19. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  20. Reconstruction of prehistoric plant production and cooking practices by a new isotopic method

    Energy Technology Data Exchange (ETDEWEB)

    Hastorf, C A [California Univ., Los Angeles (USA). Dept. of Anthropology; DeNiro, M J [California Univ., Los Angeles (USA). Dept. of Earth and Space Sciences

    1985-06-06

    A new method is presented based on isotopic analysis of burnt organic matter, allowing the characterization of previously unidentifiable plant remains extracted from archaeological contexts. The method is used to reconstruct prehistoric production, preparation and consumption of plant foods, as well as the use of ceramic vessels, in the Upper Mantaro Valley region of the central Peruvian Andes.

  1. Method of separation of fission and corrosion products and of corresponding isotopes from liquid waste

    International Nuclear Information System (INIS)

    Prochazka, H.; Stamberg, K.; Jilek, R.; Hulak, P.; Katzer, J.

    1976-01-01

    A method of separating fission and corrosion products and corresponding stable isotopes from liquid waste is described. Mycelia of fungi are used as sorbents for retaining these products on their surface and within their pores. Methods of activation or regeneration of the sorbent are outlined. 11 claims

  2. Surface area of antimony oxide by isotope exchange and other methods

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Y.K.; Acharya, B.V.; Rangamannar, B.

    1985-06-17

    Specific surface areas of antimony oxide samples, one commercial, the other prepared from antimony trichloride were measured by heterogeneous isotope exchange, gas adsorption, air permeability and microscopic methods. Specific surface areas obtained by these four methods for the two samples were compared and the observed differences are explained.

  3. Separation of argon isotopes by porous membrane method, (2)

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Fujine, Sachio; Saito, Keiichiro; Ouchi, Misao; Naruse, Yuji

    1979-08-01

    Separation characteristics of an engineering-scale cascade equipment, which is composed of five stages using Al 2 O 3 barriers, were examined under different operating conditions. This report describes the results of the separation experiment of argon isotopes by the square cascade operated under total reflux. The results are as follows: (1) Mean pore diameter and tortuosity of the barriers were estimated to be 400A and 13-15, respectively. (2) Flow mechanism through the barriers was proved to be ideal Knudsen flow by measurement of the permeability. (3) The cascade was equilibriated in 30-40 minutes, depending on stage gas inventory. (4) The effect of an operating pressure on the separation factor could be estimated by Knudsen's and Present-deBethune's theories. (5) The stage separation factor could be estimated by the conventional theoretical equations by introducing a correction factor as a function of Reynolds number of the permeating flow through the barriers. (6) An experimental equation to estimate the flow effect on the separation factor was obtained considering velocity and physical properties of the gas in the vicinity of the barrier surface. (author)

  4. Isotopic methods in hydrogeology and their application to the Underground Research Laboratory, Manitoba

    International Nuclear Information System (INIS)

    Gascoyne, M.; Kotzer, T.

    1995-09-01

    This review examines isotopic methods used to determine groundwater sources, residence times and processes of geochemical evolution that have been published in the international literature, with specific reference to AECL's experience in these methods and applications to groundwaters at the Underground Research Laboratory (URL), Manitoba. The program of groundwater sampling and analysis currently being planned for the URL area over the next several years will concentrate on specific isotopic measurements that may assist in understanding the groundwater flow system at the URL site. These results will add to the existing data for the URL area and indicate which isotopes are most useful when applied to the known groundwater flow system of the URL. This program of study is especially important because it not only uses standard geochemical and isotopic measurements (e.g., major ion, trace elements, 2 H/ 18 O, 14 C, 34 S) of groundwaters, but will determine values of more exotic and unusual ratios, such as 6 Li/ 7 Li, and B 11 /B 10 , whose potential for understanding groundwater geochemical evolution is largely unknown at present. In addition, the more established but equally complex methods of isotopic analysis, to determine 3 He/ 4 He, 36 Cl/Cl and 129 I/I, will be used to assess their potential for adding to the hydrogeochemical understanding of flow paths in crystalline rock. (author). 182 refs., 11 tabs., 27 figs

  5. Isotopic methods in hydrogeology and their application to the Underground Research Laboratory, Manitoba

    Energy Technology Data Exchange (ETDEWEB)

    Gascoyne, M [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Labs.; Kotzer, T

    1995-09-01

    This review examines isotopic methods used to determine groundwater sources, residence times and processes of geochemical evolution that have been published in the international literature, with specific reference to AECL`s experience in these methods and applications to groundwaters at the Underground Research Laboratory (URL), Manitoba. The program of groundwater sampling and analysis currently being planned for the URL area over the next several years will concentrate on specific isotopic measurements that may assist in understanding the groundwater flow system at the URL site. These results will add to the existing data for the URL area and indicate which isotopes are most useful when applied to the known groundwater flow system of the URL. This program of study is especially important because it not only uses standard geochemical and isotopic measurements (e.g., major ion, trace elements, {sup 2}H/{sup 18}O, {sup 14}C, {sup 34}S) of groundwaters, but will determine values of more exotic and unusual ratios, such as {sup 6}Li/{sup 7}Li, and B{sup 11}/B{sup 10}, whose potential for understanding groundwater geochemical evolution is largely unknown at present. In addition, the more established but equally complex methods of isotopic analysis, to determine {sup 3}He/{sup 4}He, {sup 36}Cl/Cl and {sup 129}I/I, will be used to assess their potential for adding to the hydrogeochemical understanding of flow paths in crystalline rock. (author). 182 refs., 11 tabs., 27 figs.

  6. Generator coordinate method for triaxial quadrupole collective dynamics in strontium isotopes

    International Nuclear Information System (INIS)

    Bonche, P.; Dobaczewski, J.; Flocard, H.; Heenen, P.H.

    1991-01-01

    We discuss the algebraic structure of the generator coordinate method for triaxial quadrupole collective motion. The collective solutions are classified according to the representations of the permutation group of the intrinsic axes. Our method amounts to an approximate angular momentum projection. We apply it to a study of the spherical to deformed shape transition in light even strontium isotopes 78-88 Sr. We find that triaxial configurations play a significant role in explaining the structure of the transitional isotopes 80-82 Sr

  7. Isotope analyses to explore diet and mobility in a medieval Muslim population at Tauste (NE Spain.

    Directory of Open Access Journals (Sweden)

    Iranzu Guede

    Full Text Available The Islamic necropolis discovered in Tauste (Zaragoza, Spain is the only evidence that a large Muslim community lived in the area between the 8th and 10th centuries. A multi-isotope approach has been used to investigate the mobility and diet of this medieval Muslim population living in a shifting frontier region. Thirty-one individuals were analyzed to determine δ15N, δ13C, δ18O and 87Sr/86Sr composition. A combination of strontium and oxygen isotope analysis indicated that most individuals were of local origin although three females and two males were non-local. The non-local males would be from a warmer zone whereas two of the females would be from a more mountainous geographical region and the third from a geologically-different area. The extremely high δ15N baseline at Tauste was due to bedrock composition (gypsum and salt. High individual δ15N values were related to the manuring effect and consumption of fish. Adult males were the most privileged members of society in the medieval Muslim world and, as isotope data reflected, consumed more animal proteins than females and young males.

  8. Bird migration and avian influenza: a comparison of hydrogen stable isotopes and satellite tracking methods

    Science.gov (United States)

    Bridge, Eli S.; Kelly, Jeffrey F.; Xiao, Xiangming; Takekawa, John Y.; Hill, Nichola J.; Yamage, Mat; Haque, Enam Ul; Islam, Mohammad Anwarul; Mundkur, Taej; Yavuz, Kiraz Erciyas; Leader, Paul; Leung, Connie Y.H.; Smith, Bena; Spragens, Kyle A.; Vandegrift, Kurt J.; Hosseini, Parviez R.; Saif, Samia; Mohsanin, Samiul; Mikolon, Andrea; Islam, Ausrafal; George, Acty; Sivananinthaperumal, Balachandran; Daszak, Peter; Newman, Scott H.

    2014-01-01

    Satellite-based tracking of migratory waterfowl is an important tool for understanding the potential role of wild birds in the long-distance transmission of highly pathogenic avian influenza. However, employing this technique on a continental scale is prohibitively expensive. This study explores the utility of stable isotope ratios in feathers in examining both the distances traveled by migratory birds and variation in migration behavior. We compared the satellite-derived movement data of 22 ducks from 8 species captured at wintering areas in Bangladesh, Turkey, and Hong Kong with deuterium ratios (δD) in the feathers of these and other individuals captured at the same locations. We derived likely molting locations from the satellite tracking data and generated expected isotope ratios based on an interpolated map of δD in rainwater. Although δD was correlated with the distance between wintering and molting locations, surprisingly, measured δD values were not correlated with either expected values or latitudes of molting sites. However, population-level parameters derived from the satellite-tracking data, such as mean distance between wintering and molting locations and variation in migration distance, were reflected by means and variation of the stable isotope values. Our findings call into question the relevance of the rainfall isotope map for Asia for linking feather isotopes to molting locations, and underscore the need for extensive ground truthing in the form of feather-based isoscapes. Nevertheless, stable isotopes from feathers could inform disease models by characterizing the degree to which regional breeding populations interact at common wintering locations. Feather isotopes also could aid in surveying wintering locations to determine where high-resolution tracking techniques (e.g. satellite tracking) could most effectively be employed. Moreover, intrinsic markers such as stable isotopes offer the only means of inferring movement information from

  9. Experimental substantiation of separation techniques of lead and uranium microamounts using isotopic dilution method as control method

    International Nuclear Information System (INIS)

    Agapova, A.A.; Shcherbinina, N.K.

    1983-01-01

    Methods,ensuring at low levels of contamination a high degree of lead and uranium microamount separation from solutions of geological samples, have been selected and subjected to the detailed testing. The method of isotope dilution, , combining high accuracy and sensitivity of determinations, is used as the main control methods, is used as the main control method. Using the method, processe es of uranium extpaction are traced, special attention is paid to the detailed description of lead extraction at all the stages of the methods selected. Opera ations of ion exchange for lead and uranium in microcolumns with the Bio-Rad r sin are considered, as well as operations of lead electrolytic separation. The chemical procedures suggested permit to solve one of the main methodical tasks f sample preparation, containing microgram amounts of lead and uranium, for high h-prcision measurement of their isotope composition using mass-spectrometric method

  10. Film thickness determining method of the silicon isotope superlattices by SIMS

    International Nuclear Information System (INIS)

    Takano, Akio; Shimizu, Yasuo; Itoh, Kohei M.

    2008-01-01

    It is becoming important to evaluate silicon self-diffusion with progress of a silicon semiconductor industry. In order to evaluate the self-diffusion of silicon, silicon isotope superlattices (SLs) is the only marker. For this reason, it is important to correctly evaluate a film thickness and a depth distribution of isotope SLs by secondary ion mass spectrometry (SIMS). As for film thickness, it is difficult to estimate the thicknesses correctly if the cycles of SLs are short. In this work, first, we report the determination of the film thickness for short-period SLs using mixing roughness-information (MRI) analysis to SIMS profile. Next, the uncertainty of the conventional method to determine the film thicknesses of SLs is determined. It was found that the conventional methods cannot correctly determine film thickness of short-period-isotope SLs where film thickness differs for every layer

  11. The study of multicomponent separation of Xe isotope by centrifugal method

    International Nuclear Information System (INIS)

    Jinyan Wu; Fu Zhuge

    1996-01-01

    The element Xe has nine isotopes in nature, the separation performance of each component mutually affects the others, so the binary separation theory can't be employed to study the multicomponent separation. Especially, when the molecular wight of a certain component is in the middle of its isotope components, the effect of the others on this component must be considered. In this paper, first, the multicomponent separation of Xe isotopes in a gas centrifuge is studied, with the consideration of the effect of the concentration on the diffusion coefficient and average molecular weight. The multicomponent diffusion equations are solved by the finite difference method. Second, the enrichment of Xe isotopes in a cascade is studied. On the basis of the study of a gas centrifuge, the simplified separation equations of a gas centrifuge for cascade calculation are obtained. Furthermore, the complete equations of the cascade separation are established according to the conservation of mass of each component and solved by a numerical method. The study of this paper can be extended for other isotope separation calculations. (author)

  12. ICP-MS as the method of the determination of gallium, indium and thallium isotope ratios in the studies of isotope effects in the chromatography systems

    International Nuclear Information System (INIS)

    Herdzik, I.

    2006-01-01

    The procedure of the determination of gallium, indium and thallium isotope ratios and its application to the studies of the isotope effects in chromatography systems by the ICP-MS method (inductively coupled plasma-mass spectrometry) are presented. It was shown that it is possible to determine the isotope ratios of gallium ( 69/71 Ga), indium ( 113/115 In) and thallium ( 203/205 Tl) with the relative standard deviation 0.03-0.07%. Such precision appeared to be sufficient to calculate the unit separation factors in the column chromatographic processes. (author) [pl

  13. Two isotopic methods for estimation of soybean nitrogen fixation

    International Nuclear Information System (INIS)

    Domenach, A.-M.; Chalamet, Alain; Pachiaudi, Christiane

    1979-01-01

    Measurements of rate of nitrogen symbiotic fixation by Soybean were determined by two different methods: variations in the natural abundance of 15 N in plants; use of 'A' value determined from labelled nitrogen applications to the soil. The results from both methods were in good agreement. Rates of fixed nitrogen were similar when using non nodulated Soybean or Ray-Grass as reference [fr

  14. Two isotopic methods for estimation of soybean nitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    Domenach, A M; Chalamet, A; Pachiaudi, C [Lyon-1 Univ., 69 - Villeurbanne (France)

    1979-07-16

    Measurements of rate of nitrogen symbiotic fixation by Soybean were determined by two different methods: variations in the natural abundance of /sup 15/N in plants; use of 'A' value determined from labelled nitrogen applications to the soil. The results from both methods were in good agreement. Rates of fixed nitrogen were similar when using non nodulated Soybean or Ray-Grass as reference.

  15. Characterization of a new candidate isotopic reference material for natural Pb using primary measurement method.

    Science.gov (United States)

    Nonose, Naoko; Suzuki, Toshihiro; Shin, Ki-Cheol; Miura, Tsutomu; Hioki, Akiharu

    2017-06-29

    A lead isotopic standard solution with natural abundance has been developed by applying a mixture of a solution of enriched 208 Pb and a solution of enriched 204 Pb ( 208 Pb- 204 Pb double spike solution) as bracketing method. The amount-of-substance ratio of 208 Pb: 204 Pb in this solution is accurately measured by applying EDTA titrimetry, which is one of the primary measurement methods, to each enriched Pb isotope solution. Also metal impurities affecting EDTA titration and minor lead isotopes contained in each enriched Pb isotope solution are quantified by ICP-SF-MS. The amount-of-substance ratio of 208 Pb: 204 Pb in the 208 Pb- 204 Pb double spike solution is 0.961959 ± 0.000056 (combined standard uncertainty; k = 1). Both the measurement of lead isotope ratios in a candidate isotopic standard solution and the correction of mass discrimination in MC-ICP-MS are carried out by coupling of a bracketing method with the 208 Pb- 204 Pb double spike solution and a thallium internal addition method, where thallium solution is added to the standard and the sample. The measured lead isotope ratios and their expanded uncertainties (k = 2) in the candidate isotopic standard solution are 18.0900 ± 0.0046 for 206 Pb: 204 Pb, 15.6278 ± 0.0036 for 207 Pb: 204 Pb, 38.0626 ± 0.0089 for 208 Pb: 204 Pb, 2.104406 ± 0.00013 for 208 Pb: 206 Pb, and 0.863888 ± 0.000036 for 207 Pb: 206 Pb. The expanded uncertainties are about one half of the stated uncertainty for NIST SRM 981, for 208 Pb: 204 Pb, 207 Pb: 204 Pb and 206 Pb: 204 Pb, or one eighth, for 208 Pb: 206 Pb and 207 Pb: 206 Pb, The combined uncertainty consists of the uncertainties due to lead isotope ratio measurements and the remaining time-drift effect of mass discrimination in MC-ICP-MS, which is not removed by the coupled correction method. In the measurement of 208 Pb: 204 Pb, 207 Pb: 204 Pb and 206 Pb: 204 Pb, the latter contribution is two or three times larger than the former. When the coupling of

  16. Proceedings of the symposium on isotope geology progress: technology, methods, theory and application

    International Nuclear Information System (INIS)

    2003-11-01

    The symposium was held in Beijing, Nov. 7-11, and the proceedings collects 122 articles, the contents include: new technology and new methods on isotopic test; isotope fractionation mechanism; the early evolution of the solar system and the Earth; continental dynamics and evolution of orogenic belts; minerals, energy and water; major history events on life origin, evolution and geology; changes in the Earth's global and modern environment--the oceans, the atmosphere, rivers and lakes, karst and soil, ecological agriculture and modern environment

  17. The method and program system CABEI for adjusting consistency between natural element and its isotopes data

    Energy Technology Data Exchange (ETDEWEB)

    Tingjin, Liu; Zhengjun, Sun [Chinese Nuclear Data Center, Beijing, BJ (China)

    1996-06-01

    To meet the requirement of nuclear engineering, especially nuclear fusion reactor, now the data in the major evaluated libraries are given not only for natural element but also for its isotopes. Inconsistency between element and its isotopes data is one of the main problem in present evaluated neutron libraries. The formulas for adjusting to satisfy simultaneously the two kinds of consistent relationships were derived by means of least square method, the program system CABEI were developed. This program was tested by calculating the Fe data in CENDL-2.1. The results show that adjusted values satisfy the two kinds of consistent relationships.

  18. Exogenous surfactant kinetics in infant respiratory distress syndrome : A novel method with stable isotopes

    NARCIS (Netherlands)

    Torresin, M; Zimmermann, LJI; Cogo, PE; Cavicchioli, P; Badon, T; Giordano, G; Zacchello, F; Sauer, PJJ; Carnielli, VP

    Little is known about surfactant metabolism in newborn infants, since radioactive isotopes cannot be used in humans. We describe here a new method for studying exogenous surfactant pharmacokinetics in vivo. We measured surfactant half-life, pool size, and turnover time in eight preterm infants

  19. Isotopic method for investigation of process of periodic sedimentation of argillaceous suspensions

    International Nuclear Information System (INIS)

    Kohman, L.; Woznicki, T.

    1976-01-01

    The process of periodic sedimentation of kaolinic suspension in water has been investigated, by isotopic tracer method. the tracer was either the irradiated matrix material or 198 Au, adsorbed on the kaolin grains. The velocity of suspension level lowering (the sedimentation curve) and the variation in density in vertical section of sediment layer have been determined. (author)

  20. A simplified method for obtaining high-purity perchlorate from groundwater for isotope analyses.

    Energy Technology Data Exchange (ETDEWEB)

    vonKiparski, G; Hillegonds, D

    2011-04-04

    Investigations into the occurrence and origin of perchlorate (ClO{sub 4}{sup -}) found in groundwater from across North America have been sparse until recent years, and there is mounting evidence that natural formation mechanisms are important. New opportunities for identifying groundwater perchlorate and its origin have arisen with the utilization of improved detection methods and sampling techniques. Additionally, application of the forensic potential of isotopic measurements has begun to elucidate sources, potential formation mechanisms and natural attenuation processes. Procedures developed appear to be amenable to enable high precision stable isotopic analyses, as well as lower precision AMS analyses of {sup 36}Cl. Immediate work is in analyzing perchlorate isotope standards and developing full analytical accuracy and uncertainty expectations. Field samples have also been collected, and will be analyzed when final qa/qc samples are deemed acceptable.

  1. Isotopic method of testing the dynamics of melt flow through a sedimentation tank

    International Nuclear Information System (INIS)

    Bazaniak, Z.; Chamer, R.; Stec, J.; Przybytniak, W.

    1981-01-01

    The isotopic method of a simultaneous measurement of copper matte and slag flow parameters is discussed. For marking Cu-64 and Zr 95/97, isotopes characterized by various gamma radiation energy are used. The chemical form of copper and zirconium compounds was chosen from the viewpoint of assuring a selective solubility in the tested phases. To interpret the results of isotopic tests, the Wolf-Resnick model was made. The obtained results have confirmed the hypothesis of a possible occurrence of the copper matte flotation effect. In order to reduce of copper uplifted with the shaft slag, a redesigning is suggested of the sedimentation tank that would assure a reduction of the ideal mixing participation and an increase of the zone characterized by the piston flow. (author)

  2. A New Method to Quantify the Isotopic Signature of Leaf Transpiration: Implications for Landscape-Scale Evapotranspiration Partitioning Studies

    Science.gov (United States)

    Wang, L.; Good, S. P.; Caylor, K. K.

    2010-12-01

    Characterizing the constituent components of evapotranspiration is crucial to better understand ecosystem-level water budgets and water use dynamics. Isotope based evapotranspiration partitioning methods are promising but their utility lies in the accurate estimation of the isotopic composition of underlying transpiration and evaporation. Here we report a new method to quantify the isotopic signature of leaf transpiration under field conditions. This method utilizes a commercially available laser-based isotope analyzer and a transparent leaf chamber, modified from Licor conifer leaf chamber. The method is based on the water mass balance in ambient air and leaf transpired air. We verified the method using “artificial leaves” and glassline extracted samples. The method provides a new and direct way to estimate leaf transpiration isotopic signatures and it has wide applications in ecology, hydrology and plant physiology.

  3. A TIMS-based method for the high precision measurements of the three-isotope potassium composition of small samples

    DEFF Research Database (Denmark)

    Wielandt, Daniel Kim Peel; Bizzarro, Martin

    2011-01-01

    A novel thermal ionization mass spectrometry (TIMS) method for the three-isotope analysis of K has been developed, and ion chromatographic methods for the separation of K have been adapted for the processing of small samples. The precise measurement of K-isotopes is challenged by the presence of ...

  4. Uranium isotopic separation by aerodynamic methods. Final report

    International Nuclear Information System (INIS)

    Davidovitz, P.; Anderson, J.B.; Brook, J.W.; Calia, V.S.; Greene, G.T.

    1979-06-01

    Two aerodynamic separation techniques for uranium enrichment were investigated for technical feasibility and economic viability. These techniques are known as the Jet Membrane and Velocity Slip Processes. Both analytical and laboratory studies were conducted to explore the technical feasibility of the subject processes. The Jet Membrane Process Studies demonstrated that the process was feasible and that a condensable gas carrier is available. The Velocity Slip Studies demonstrated the predicted effects and did not identify a suitable condensable gas carrier. Hence the Velocity Slip Process exhibited a larger power consumption than did the Jet Membrane Process. An independent contractor prepared detailed cost estimates of the process. The independent results indicated that, based on the same costing ground rules, the Velocity Slip process would require 16 times the fixed capital costs and 12 times the cost per separative work unit as compared to the Jet Membrane Process. The same cost structure indicated that the cost per separative work unit for the Jet Membrane process would be two to three times that for the Gas Centrifuge process. There are a number of uncertainties associated with these cost estimates, such that, in the extreme, the costs might be the same. Further, more detailed cost analysis would be required to resolve the uncertainties associated with the initial cost estimates. The conduct of new studies was not considered to be appropriate for EPRI because of the changes in enrichment program management and security philosophy discussed in the text

  5. Assembly of greek marble inscriptions by isotopic methods.

    Science.gov (United States)

    Herz, N; Wenner, D B

    1978-03-10

    Classical Greek inscriptions cut in marble, whose association as original stelai by archeological methods was debatable, were selected for study. Using traditional geological techniques and determinations of the per mil increments in carbon-13 and oxygen-18, it was determined that fragments could be positively assigned to three stelai, but that fragments from three other stelai had been incorrectly associated.

  6. Isotope separation

    International Nuclear Information System (INIS)

    Eerkens, J.W.

    1979-01-01

    A method of isotope separation is described which involves the use of a laser photon beam to selectively induce energy level transitions of an isotope molecule containing the isotope to be separated. The use of the technique for 235 U enrichment is demonstrated. (UK)

  7. Development of High Flux Isotope Reactor (HFIR) subcriticality monitoring methods

    International Nuclear Information System (INIS)

    Rothrock, R.B.

    1991-01-01

    Use of subcritical source multiplication measurements during refueling has been investigated as a possible replacement for out-of-reactor subcriticality measurements formerly made on fresh HFIR fuel elements at the ORNL Critical Experiment Facility. These measurements have been used in the past for preparation of estimated critical rod positions, and as a partial verification, prior to reactor startup, that the requirements for operational shutdown margin would be met. Results of subcritical count rate data collection during recent HFIR refuelings and supporting calculations are described illustrating the intended measurement method and its expected uncertainty. These results are compared to historical uses of the out-of-reactor core measurements and their accuracy requirements, and a planned in-reactor test is described which will establish the sensitivity of the method and calibrate it for future routine use during HFIR refueling. 2 refs., 1 fig., 2 tabs

  8. A method to extract soil water for stable isotope analysis

    Science.gov (United States)

    Revesz, Kinga; Woods, Peter H.

    1990-07-01

    A method has been developed to extract soil water for determination of deuterium (D) and 18O content. The principle of this method is based on the observation that water and toluene form an azeotropic mixture at 84.1°C, but are completely immiscible at ambient temperature. In a specially designed distillation apparatus, the soil water is distilled at 84.1°C with toluene and is separated quantitatively in the collecting funnel at ambient temperature. Traces of toluene are removed and the sample can be analyzed by mass spectrometry. Kerosene may be substituted for toluene. The accuracy of this technique is ± 2 and ± 0.2‰, respectively, for δD and δ 18O. Reduced accuracy is obtained at low water contents.

  9. Evolution of uranium isotope separation methods in France

    International Nuclear Information System (INIS)

    Frejacques, C.; Gelee, M.; Massignon, D.; Plurien, P.

    This paper examines the various processes for producing enriched U, from the dual standpoint of evolution of their technical-economic performances and the proliferation risks involved. The gaseous diffusion process is first examined as a reference; then centrifugation, aerodynamic processes, chemical exchange processes, photochemical excitation processes, and ionic processes are considered. It is concluded that the first four methods may be competitive in the next decade

  10. "Whole" Ballet Education: Exploring Direct and Indirect Teaching Methods

    Science.gov (United States)

    Choi, Euichang; Kim, Na-ye

    2015-01-01

    The purpose of this study was to explore teaching methods for whole ballet in Korean ballet education. This study built upon a first phase of research that identified the educational content of "whole" ballet. Four dimensions were identified as the educational content: "physical," "cognitive," "emotional"…

  11. Exploring Intercultural Sensitivity in Early Adolescence: A Mixed Methods Study

    Science.gov (United States)

    Mellizo, Jennifer M.

    2017-01-01

    The purpose of this mixed methods study was to explore levels of intercultural sensitivity in a sample of fourth to eighth grade students in the United States (n = 162). "Intercultural sensitivity" was conceptualised through Bennett's Developmental Model of Sensitivity, and assessed through the Adapted Intercultural Sensitivity Index.…

  12. Two-step extraction method for lead isotope fractionation to reveal anthropogenic lead pollution.

    Science.gov (United States)

    Katahira, Kenshi; Moriwaki, Hiroshi; Kamura, Kazuo; Yamazaki, Hideo

    2018-05-28

    This study developed the 2-step extraction method which eluted the Pb adsorbing on the surface of sediments in the first solution by aqua regia and extracted the Pb absorbed inside particles into the second solution by mixed acid of nitric acid, hydrofluoric acid and hydrogen peroxide solution. We applied the method to sediments in the enclosed water area and found out that the isotope ratios of Pb in the second solution represented those of natural origin. This advantage of the method makes it possible to distinguish the Pb between natural origin and anthropogenic source on the basis of the isotope ratios. The results showed that the method was useful to discuss the Pb sources and that anthropogenic Pb in the sediment samples analysed was mainly derived from China because of transboundary air pollution.

  13. Application and validation of isotope dilution method (IDM) for predicting bioavailability of hydrophobic organic contaminants in soil.

    Science.gov (United States)

    Wang, Jie; Taylor, Allison; Schlenk, Daniel; Gan, Jay

    2018-05-01

    Risk assessment of hydrophobic organic contaminants (HOCs) using the total chemical concentration following exhaustive extraction may overestimate the actual availability of HOCs to non-target organisms. Existing methods for estimating HOC bioavailability in soil have various operational limitations. In this study, we explored the application of isotope dilution method (IDM) to quantify the accessible fraction (E) of DDTs and PCBs in both historically-contaminated and freshly-spiked soils. After addition of 13 C or deuterated analogues to a soil sample, the phase distribution of isotope-labeled and native chemicals reached an apparent equilibrium within 48 h of mixing. The derived E values in the three soils ranged from 0.19 to 0.82, depending on the soil properties and also the contact time of HOCs (i.e., aging). The isotope dilution method consistently predicted greater accumulation into earthworm (Eisenia fetida) than that by polyethylene (PE) or solid phase microextraction (SPME) sampler, likely because desorption in the gut enhanced bioavailability of soil-borne HOCs. A highly significant linear regression (R 2  = 0.91) was found between IDM and 24-h Tenax desorption, with a slope statistically identical to 1. The IDM-derived accessible concentration (C e ) was further shown to accurately predict tissue residues in earthworm exposed in the same soils. Given the relatively short duration and simple steps, IDM has the potential to be readily adopted for measuring HOC bioaccessibility in soil and for improving risk assessment and evaluation of remediation efficiency. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Method to separate deuterium isotopes using ethylene and ethylene dichloride

    International Nuclear Information System (INIS)

    Benson, S.W.

    1979-01-01

    The separation of deuterium by the dissociation of ethylene vinyl chloride, 1,2-dichloro-ethanes or propylene with the help of intensive, matched infrared lasers enables a relatively good yield if operated on a large scale, e.g. in refineries with large through-put. The deuterium from the laser photolysis of ethylene and vinyl chloride is found in the acetylene formed, which has to be separated off and processed. When using dichloroehtane, the deuterium is found in the vinal chloride formed. The methods are briefly described. (UWI) [de

  15. Simple radio-isotopic method for the detection of bronchial inhalation during intensive care

    Energy Technology Data Exchange (ETDEWEB)

    Venot, J.; Veyriras, E.; Vandroux, J.C.; Bournaud, E.; Gastinne, H.; Beck, C.

    1984-08-01

    The high incidence of pneumopathy in intensive care units might be due to the pulmonary aspiration of gastric juice following gastro-oesophageal reflux. The paper describes a radio-isotopic method using material easy to install at the patient's bedside. This technique demonstrated aspiration of gastric juice in the lungs of 8 of 25 intensive care patients investigated. Such a method might be useful later to demonstrate that silent bronchial aspirations of gastric juice are responsible for pulmonary complications.

  16. Memory Effects Study of Measuring Radioactive Xenon Isotopes With β-γ Coincidence Method

    International Nuclear Information System (INIS)

    Jia Huaimao; Wang Shilian; Wang Jun; Li Qi; Zhao Yungang; Fan Yuanqing; Zhang Xinjun

    2010-01-01

    The β-γ coincidence technique is a kind of the key important method to detect radioactive xenon isotopes for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). This paper describes noble gases memory effects of β-γ coincidence detector. Xenon memory effects were measured and its influence on detector's minimum detectable activity (MDA) was evaluated. The methods of reducing xenon memory effects were studied. In conclusion, aluminium coated plastic scintillator and YAP scintillator can remarkably decrease xenon memory effects. (authors)

  17. Chemical methods for Sm-Nd separation and its application in isotopic geological dating

    International Nuclear Information System (INIS)

    Guo Qifeng.

    1990-01-01

    Three chemical methods for Sm-Nd separation are mainly desribed: low chromatography of butamone-ammonium thiocyanate for hight concentration Sm and Nd separation, P 240 column chromatography for medium concentration Sm-Nd separation, and pressure ion exchange for low concentration Sm-Nd. The first Sm-Nd synchrone obtained in China with Sm-Nd methods is introduced and Sm-Nd isotopic geological dating in Early Archaean rocks in eastern Hebei has been determined

  18. Use of the isotope method to measure breast milk intake

    International Nuclear Information System (INIS)

    Dos Santos, I.; Victoria, C.G.

    2000-01-01

    A study to test the efficacy of the nutrition counselling (NC) contents of integrated Management of Childhood Illnesses Course (IMCI, WHO/UNICEF), funded by WHO, was planned and conducted in Pelotas (southern Brazil). The study was a single-blind randomized controlled trial with the random allocation of 14 municipal health centres to receive the NC training and 14 other centres to the control group (current nutrition counselling, if any). The study included testing the knowledge of doctors, observing consultations and visiting the children at home 8, 45 and 180 days after the initial consultation. Dietary intakes were studied on a sub-sample of 66 children (two per health care provider), through daylong observations. Breast milk intake was assessed by the frequency and duration of feeds. The deuterium study was carried out in the same population to validate breast milk intake estimates. The deuterium study was a cross-sectional assessment of breast milk intake among those children enrolled in the day long sub-sample. From the 66 children visited by the day long study, 18 were still breast fed and were selected for the deuterium study. A total of 11 saliva samples were collected from each mother/child pair at a 15-day interval: four from the mother (on days 0, 1, 6 and 14) and seven from the child (on days 0, 1, 2, 5, 6, 13, and 14). The Pearson correlation coefficient comparing the amount of milk as estimated by observation and the amount calculated through the deuterium technique (gold standard) was equal to 0.53. This result indicates that the estimates based on the frequency and the duration of breastfeeding through observation correlated to the results of the gold standard method for breast milk intake assessment, although this correlation was of moderate strength. As the gold standard, the deuterium method showed to be practical and easily to perform at field setting. (author)

  19. Use of the isotope method to measure breast milk intake

    Energy Technology Data Exchange (ETDEWEB)

    Dos Santos, I; Victoria, C G [Departamento de Medicina Social, Faculdade de Medicina, Universidade Federal de Pelotas, Pelotas, RS (Brazil)

    2000-07-01

    A study to test the efficacy of the nutrition counselling (NC) contents of integrated Management of Childhood Illnesses Course (IMCI, WHO/UNICEF), funded by WHO, was planned and conducted in Pelotas (southern Brazil). The study was a single-blind randomized controlled trial with the random allocation of 14 municipal health centres to receive the NC training and 14 other centres to the control group (current nutrition counselling, if any). The study included testing the knowledge of doctors, observing consultations and visiting the children at home 8, 45 and 180 days after the initial consultation. Dietary intakes were studied on a sub-sample of 66 children (two per health care provider), through daylong observations. Breast milk intake was assessed by the frequency and duration of feeds. The deuterium study was carried out in the same population to validate breast milk intake estimates. The deuterium study was a cross-sectional assessment of breast milk intake among those children enrolled in the day long sub-sample. From the 66 children visited by the day long study, 18 were still breast fed and were selected for the deuterium study. A total of 11 saliva samples were collected from each mother/child pair at a 15-day interval: four from the mother (on days 0, 1, 6 and 14) and seven from the child (on days 0, 1, 2, 5, 6, 13, and 14). The Pearson correlation coefficient comparing the amount of milk as estimated by observation and the amount calculated through the deuterium technique (gold standard) was equal to 0.53. This result indicates that the estimates based on the frequency and the duration of breastfeeding through observation correlated to the results of the gold standard method for breast milk intake assessment, although this correlation was of moderate strength. As the gold standard, the deuterium method showed to be practical and easily to perform at field setting. (author)

  20. Quantifying the isotopic composition of NOx emission sources: An analysis of collection methods

    Science.gov (United States)

    Fibiger, D.; Hastings, M.

    2012-04-01

    We analyze various collection methods for nitrogen oxides, NOx (NO2 and NO), used to evaluate the nitrogen isotopic composition (δ15N). Atmospheric NOx is a major contributor to acid rain deposition upon its conversion to nitric acid; it also plays a significant role in determining air quality through the production of tropospheric ozone. NOx is released by both anthropogenic (fossil fuel combustion, biomass burning, aircraft emissions) and natural (lightning, biogenic production in soils) sources. Global concentrations of NOx are rising because of increased anthropogenic emissions, while natural source emissions also contribute significantly to the global NOx burden. The contributions of both natural and anthropogenic sources and their considerable variability in space and time make it difficult to attribute local NOx concentrations (and, thus, nitric acid) to a particular source. Several recent studies suggest that variability in the isotopic composition of nitric acid deposition is related to variability in the isotopic signatures of NOx emission sources. Nevertheless, the isotopic composition of most NOx sources has not been thoroughly constrained. Ultimately, the direct capture and quantification of the nitrogen isotopic signatures of NOx sources will allow for the tracing of NOx emissions sources and their impact on environmental quality. Moreover, this will provide a new means by which to verify emissions estimates and atmospheric models. We present laboratory results of methods used for capturing NOx from air into solution. A variety of methods have been used in field studies, but no independent laboratory verification of the efficiencies of these methods has been performed. When analyzing isotopic composition, it is important that NOx be collected quantitatively or the possibility of fractionation must be constrained. We have found that collection efficiency can vary widely under different conditions in the laboratory and fractionation does not vary

  1. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  2. Application of Electrical Resistivity Method (ERM) in Groundwater Exploration

    Science.gov (United States)

    Izzaty Riwayat, Akhtar; Nazri, Mohd Ariff Ahmad; Hazreek Zainal Abidin, Mohd

    2018-04-01

    The geophysical method which dominant by geophysicists become one of most popular method applied by engineers in civil engineering fields. Electrical Resistivity Method (ERM) is one of geophysical tool that offer very attractive technique for subsurface profile characterization in larger area. Applicable alternative technique in groundwater exploration such as ERM which complement with existing conventional method may produce comprehensive and convincing output thus effective in terms of cost, time, data coverage and sustainable. ERM has been applied by various application in groundwater exploration. Over the years, conventional method such as excavation and test boring are the tools used to obtain information of earth layer especially during site investigation. There are several problems regarding the application of conventional technique as it only provides information at actual drilling point only. This review paper was carried out to expose the application of ERM in groundwater exploration. Results from ERM could be additional information to respective expert for their problem solving such as the information on groundwater pollution, leachate, underground and source of water supply.

  3. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyses - Review

    International Nuclear Information System (INIS)

    Skrzypek, G.; Sadler, R.; Paul, D.; Forizs, I.

    2011-01-01

    A stable isotope analyst has to make a number of important decisions regarding how to best determine the 'true' stable isotope composition of analysed samples in reference to an international scale. It has to be decided which reference materials should be used, the number of reference materials and how many repetitions of each standard is most appropriate for a desired level of precision, and what normalization procedure should be selected. In this paper we summarise what is known about propagation of uncertainties associated with normalization procedures and propagation of uncertainties associated with reference materials used as anchors for the determination of 'true' values for δ''1''3C and δ''1''8O. Normalization methods Several normalization methods transforming the 'raw' value obtained from mass spectrometers to one of the internationally recognized scales has been developed. However, as summarised by Paul et al. different normalization transforms alone may lead to inconsistencies between laboratories. The most common normalization procedures are: single-point anchoring (versus working gas and certified reference standard), modified single-point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two-point and multipoint linear normalization methods. The accuracy of these various normalization methods has been compared by using analytical laboratory data by Paul et al., with the single-point and normalization versus tank calibrations resulting in the largest normalization errors, and that also exceed the analytical uncertainty recommended for δ 13 C. The normalization error depends greatly on the relative differences between the stable isotope composition of the reference material and the sample. On the other hand, the normalization methods using two or more certified reference standards produces a smaller normalization error, if the reference materials are bracketing the whole range of

  4. A dynamic isotope power system for Space Exploration Initiative surface transport systems

    International Nuclear Information System (INIS)

    Hunt, M.E.; Harty, R.B.; Cataldo, R.

    1992-03-01

    The Dynamic Isotope Power System (DIPS) Demonstration Program, sponsored by the U.S. Department of Energy with support funding from NASA, is currently focused on the development of a standardized 2.5-kWe portable generator for multiple applications on the lunar or Martian surface. A variety of remote and mobile potential applications have been identified by NASA, including surface rovers for both short- and extended-duration missions, remote power to science packages, and backup to central base power. Recent work focused on refining the 2.5-kWe design and emphasizing the compatibility of the system with potential surface transport systems. Work included an evaluation of the design to ensure compatibility with the Martian atmosphere while imposing only a minor mass penalty on lunar operations. Additional work included a study performed to compare the DIPS with regenerative fuel cell systems for lunar mobile and remote power systems. Power requirements were reviewed and a modular system chosen for the comparison. 4 refs

  5. A celestial assisted INS initialization method for lunar explorers.

    Science.gov (United States)

    Ning, Xiaolin; Wang, Longhua; Wu, Weiren; Fang, Jiancheng

    2011-01-01

    The second and third phases of the Chinese Lunar Exploration Program (CLEP) are planning to achieve Moon landing, surface exploration and automated sample return. In these missions, the inertial navigation system (INS) and celestial navigation system (CNS) are two indispensable autonomous navigation systems which can compensate for limitations in the ground based navigation system. The accurate initialization of the INS and the precise calibration of the CNS are needed in order to achieve high navigation accuracy. Neither the INS nor the CNS can solve the above problems using the ground controllers or by themselves on the lunar surface. However, since they are complementary to each other, these problems can be solved by combining them together. A new celestial assisted INS initialization method is presented, in which the initial position and attitude of the explorer as well as the inertial sensors' biases are estimated by aiding the INS with celestial measurements. Furthermore, the systematic error of the CNS is also corrected by the help of INS measurements. Simulations show that the maximum error in position is 300 m and in attitude 40″, which demonstrates this method is a promising and attractive scheme for explorers on the lunar surface.

  6. A Celestial Assisted INS Initialization Method for Lunar Explorers

    Directory of Open Access Journals (Sweden)

    Jiancheng Fang

    2011-07-01

    Full Text Available The second and third phases of the Chinese Lunar Exploration Program (CLEP are planning to achieve Moon landing, surface exploration and automated sample return. In these missions, the inertial navigation system (INS and celestial navigation system (CNS are two indispensable autonomous navigation systems which can compensate for limitations in the ground based navigation system. The accurate initialization of the INS and the precise calibration of the CNS are needed in order to achieve high navigation accuracy. Neither the INS nor the CNS can solve the above problems using the ground controllers or by themselves on the lunar surface. However, since they are complementary to each other, these problems can be solved by combining them together. A new celestial assisted INS initialization method is presented, in which the initial position and attitude of the explorer as well as the inertial sensors’ biases are estimated by aiding the INS with celestial measurements. Furthermore, the systematic error of the CNS is also corrected by the help of INS measurements. Simulations show that the maximum error in position is 300 m and in attitude 40″, which demonstrates this method is a promising and attractive scheme for explorers on the lunar surface.

  7. Theory of isotope scanning; Theorie de l'Exploration par les Radioisotopes; Teoriya meditsinskikh issledovanij s primeneniem izotopov; Teoria de la exploracion mediante radioisotopos

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G L [Physics Research Laboratory, Massachusetts General Hospital, Boston, MA (United States)

    1959-07-01

    The visualization of isotope distributions is an important aspect of the medical use of radioisotopes. The sensitivity patterns of various collimating systems are compared and their efficiency and resolution calculated. The collimating systems considered consist of cylindrical and tapered apertures, focusing collimators, and coincidence detection of annihilation radiation. A general theory is derived to give the optimum isotope concentration for each of the systems. A similar theory is derived to cover the scintillation camera and a comparison is made of the optimum isotope concentration of this device in relation to scanning methods. A modification of the camera concept for use with annihilation radiation is discussed. Various recording systems are compared as to efficiency and information presentation. (author) [French] La representation visuelle de la repartition des isotopes est un aspect important de l'utilisation des radioisotopes en medecine. L'auteur compare les types de sensibilite de divers systemes de collimation et calcule leur efficacite et leur pouvoir de resolution. Les systemes consideres se composent d'orifices cylindriques ou coniques, de collimateurs a focalisation et des dispositifs permettant de detecter par coincidences les rayonnements d'annihilation. Il en tire une theorie generale en vue de donner la concentration optimum d'isotopes pour chacun de ces systemes. L'auteur expose une theorie analogue pour la chambre a scintillations et procede a une comparaison de la concentration optimum d'isotopes dans le cas de cet appareil, par rapport aux resultats obtenus au moyen des methodes d'exploration. Il etudie la possibilite de modifier le principe de la chambre pour l'appliquer a la detection des rayonnements d'annihilation. Il compare divers systemes d'enregistrement du point de vue de leur efficacite et de la presentation des renseignements. (author) [Spanish] La representacion visual de la distribucion de los isotopos constituye un importante

  8. U Exploration Using Magnetic Method On Bubu Sector, West Kalimantan

    International Nuclear Information System (INIS)

    Nurdin, M.; Subardjo; Darmono, S.; Slamet, S.

    1996-01-01

    The exploration was based on the discovery of association of U mineralization with magnetite, ilmenite, pyrite and pyrrhotite minerals which are fill in the NW-SE fracturations The aim and objective of exploration is to find depth and size of sub surface mineralization zone Magnetic method was chosen because the method was good for metallic detection The measured and plotted as contour map is total magnetic field; from the contour map shown there are 4 NW-SE magnetic poles The result of the modelling body using Geosoft Software was gotten 2 dimension of mineralization. The result of stacking the model on the geological map is width of the zone; it is 25 meter and the depth about 3.5 meter in quartzite and pyrrhotite, has NW-SE direction and controlled by structure

  9. PROMETHEE II: A knowledge-driven method for copper exploration

    Science.gov (United States)

    Abedi, Maysam; Ali Torabi, S.; Norouzi, Gholam-Hossain; Hamzeh, Mohammad; Elyasi, Gholam-Reza

    2012-09-01

    This paper describes the application of a well-known Multi Criteria Decision Making (MCDM) technique called Preference Ranking Organization METHod for Enrichment Evaluation (PROMETHEE II) to explore porphyry copper deposits. Various raster-based evidential layers involving geological, geophysical, and geochemical geo-datasets are integrated to prepare a mineral prospectivity mapping (MPM). In a case study, thirteen layers of the Now Chun copper deposit located in the Kerman province of Iran are used to explore the region of interest. The PROMETHEE II technique is applied to produce the desired MPM, and the outputs are validated using twenty-one boreholes that have been classified into five classes. This proposed method shows a high performance when providing the MPM while reducing the cost of exploratory drilling in the study area.

  10. Reverse isotope dilution method for determining benzene and metabolites in tissues

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.

    1988-01-01

    A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of the radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue

  11. Application of isotopic and chemical methods to the study of hydrological problems in Brazilian northeastern areas

    International Nuclear Information System (INIS)

    Ponte, J.H.

    1979-01-01

    Hydrological studies are reported with samples of ground water from several region of northern - and northeastern Brazil: Marajo Island (State of Para), State of Piaui, Ceara and Rio Grande do Norte. A description is given of the utilization of chemical and isotopic methods, in particular measurements of tritium concentration and 14 C- counting techniques for the determination of the origin and residence time of water. (I.C.R.) [pt

  12. A new method for studying iodine metabolism; the isotopic equilibrium method - kinetic and quantitative aspects of measurements made on rats

    International Nuclear Information System (INIS)

    Simon, C.

    1964-05-01

    The isotopic equilibrium method which has been developed in the case of the rat has made it possible to measure the absolute values of the principal parameters of iodine metabolism in this animal. The quantities and concentrations of iodine have been measured in the thyroid gland and in the plasma with a sensitivity of 0.001 μg of 127 I. This sensitivity has made it possible to measure pools as small as the iodide and the free iodotyrosines of the thyroid and to demonstrate the absence of free iodotyrosines in the plasma of the normal rat. In vivo, the isotopic equilibrium method has made it possible to measure the iodine content of the thyroid gland and to calculate the intensity of this gland's secretion without removing it. By double labelling with 125 I and 131 I the isotopic equilibrium method has made it possible to measure the flux, intensity of the intrathyroidal recycling as well as the turnover rates of all the iodine containing compounds of the thyroid gland. For this gland no precursor-product relationship has been found between The iodotyrosines (MIT and DIT) and the iodothyronines (T 4 and T 3 ). The absence of this relationship is due to the heterogeneity of the thyroglobulin turnover. It has been shown furthermore that there exists in the plasma an organic fraction of the iodine which is different to thyroglobulin and which is renewed more rapidly than the circulating hormones T 3 and T 4 . The isotopic equilibrium method is very useful for series measurements of iodine. It makes it possible furthermore to improve the biochemical fractionations by adding carriers without affecting the subsequent 127 I measurements. (author) [fr

  13. A Sweep-Line Method for State Space Exploration

    DEFF Research Database (Denmark)

    Christensen, Søren; Kristensen, Lars Michael; Mailund, Thomas

    2001-01-01

    generation, since these states can never be reached again. This in turn reduces the memory used for state space storage during the task of verification. Examples of progress measures are sequence numbers in communication protocols and time in certain models with time. We illustrate the application...... of the method on a number of Coloured Petri Net models, and give a first evaluation of its practicality by means of an implementation based on the Design/CPN state space tool. Our experiments show significant reductions in both space and time used during state space exploration. The method is not specific...... to Coloured Petri Nets but applicable to a wide range of modelling languages....

  14. Evaluation of Isotope 32P Method to Mark Culex pipiens (Diptera: Culicidae in a Laboratory

    Directory of Open Access Journals (Sweden)

    Chongxing Zhang

    2016-01-01

    Full Text Available Background: The aim of the current study was to develop a marking technique as an internal marker to mark post blood meal mosquitoes by using stable phosphate isotope 32P and determine the optimal concentration of it.Methods: An isotonic physiological saline solution, containing different concentration of radioactive isotope 32P-labeled disodium phosphate (Na2H32PO4 was injected into rabbits via the jugular vein in the laboratory. Emerged Cx. pipiens were marked after feeding on rabbit. At the same time, the labeled conditions of emerged Cx. pipiens were also measured by placing feces of No. 6 rabbit into containers with mosquito larvae and pupae inside.Results: According to the label condition of Cx. pipiens after taking blood and the effect of different dosage Na2H32PO4 on rabbit health, the optimal concentration of radioactive isotope was determined, that is, 0.1211 mCi/kg. By placing feces of No. 6 rabbit into containers with mosquito larvae and pupae inside, the emerged mosquitoes were also labeled. Therefore, feeding mosquitoes on the animal injected with radioactive Na2H32PO4 was more prac­tical for detecting and tracing mosquitoes.Conclusion: The method was less time-consuming, more sensitive and safer. This marking method will facilitate post-bloodmeal studies of mosquitoes and other blood-sucking insects.

  15. Accelerated weight histogram method for exploring free energy landscapes

    Energy Technology Data Exchange (ETDEWEB)

    Lindahl, V.; Lidmar, J.; Hess, B. [Department of Theoretical Physics and Swedish e-Science Research Center, KTH Royal Institute of Technology, 10691 Stockholm (Sweden)

    2014-07-28

    Calculating free energies is an important and notoriously difficult task for molecular simulations. The rapid increase in computational power has made it possible to probe increasingly complex systems, yet extracting accurate free energies from these simulations remains a major challenge. Fully exploring the free energy landscape of, say, a biological macromolecule typically requires sampling large conformational changes and slow transitions. Often, the only feasible way to study such a system is to simulate it using an enhanced sampling method. The accelerated weight histogram (AWH) method is a new, efficient extended ensemble sampling technique which adaptively biases the simulation to promote exploration of the free energy landscape. The AWH method uses a probability weight histogram which allows for efficient free energy updates and results in an easy discretization procedure. A major advantage of the method is its general formulation, making it a powerful platform for developing further extensions and analyzing its relation to already existing methods. Here, we demonstrate its efficiency and general applicability by calculating the potential of mean force along a reaction coordinate for both a single dimension and multiple dimensions. We make use of a non-uniform, free energy dependent target distribution in reaction coordinate space so that computational efforts are not wasted on physically irrelevant regions. We present numerical results for molecular dynamics simulations of lithium acetate in solution and chignolin, a 10-residue long peptide that folds into a β-hairpin. We further present practical guidelines for setting up and running an AWH simulation.

  16. Explorative analysis of major components and isotopes. SDM-Site Forsmark

    Energy Technology Data Exchange (ETDEWEB)

    Smellie, John (Conterra AB (Sweden)); Tullborg, Eva-Lena (Terralogica AB (Sweden)); Nilsson, Ann-Chatrin (Geosigma AB (Sweden)); Sandstroem, Bjoern (Goeteborg Univ. (Sweden)); Waber, Niklaus (Univ. of Bern (Switzerland)); Gimeno, Maria (Univ. of Zaragoza (Spain)); Gascoyne, Mel (GGP Inc. (United Kingdom))

    2008-09-15

    The overall objectives of the hydrogeochemical description for Forsmark are to establish a detailed understanding of the hydrogeochemical conditions at the site and to develop models that fulfil the needs identified by the safety assessment groups during the site investigation phase. Issues of concern to safety assessment are radionuclide transport and technical barrier behaviour, both of which are dependent on the chemistry of groundwater and pore water and their evolution with time. The work has involved the development of descriptive and mathematical models for groundwaters in relation to rock domains, fracture domains and deformation zones. Past climate events are the major driving force for hydrogeochemical changes and therefore are of fundamental importance for understanding the palaeohydrogeological, palaeohydrogeochemical and present evolution of groundwater in the crystalline bedrock of the Fennoscandian Shield. Understanding current undisturbed hydrochemical conditions at the proposed repository site is important when predicting future changes in groundwater chemistry. The causes behind copper corrosion and/or bentonite degradation are of particular interest as they may jeopardise the long-term integrity of the planned SKB repository system. Thus, the following variables are considered for the hydrogeochemical site descriptive modelling: pH, Eh, sulphur species, iron, manganese, carbonate, phosphate, nitrogen species, total dissolved solids (TDS), isotopes, colloids, fulvic and humic acids and microorganisms. In addition, dissolved gases (e.g. carbon dioxide, methane and hydrogen) are of interest because of their likely participation in microbial reactions. In this series of reports, the final hydrogeochemical evaluation work of the site investigation at the Forsmark site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and university researchers with expertise in

  17. Explorative analysis of major components and isotopes. SDM-Site Forsmark

    International Nuclear Information System (INIS)

    Smellie, John; Tullborg, Eva-Lena; Nilsson, Ann-Chatrin; Sandstroem, Bjoern; Waber, Niklaus; Gimeno, Maria; Gascoyne, Mel

    2008-09-01

    The overall objectives of the hydrogeochemical description for Forsmark are to establish a detailed understanding of the hydrogeochemical conditions at the site and to develop models that fulfil the needs identified by the safety assessment groups during the site investigation phase. Issues of concern to safety assessment are radionuclide transport and technical barrier behaviour, both of which are dependent on the chemistry of groundwater and pore water and their evolution with time. The work has involved the development of descriptive and mathematical models for groundwaters in relation to rock domains, fracture domains and deformation zones. Past climate events are the major driving force for hydrogeochemical changes and therefore are of fundamental importance for understanding the palaeohydrogeological, palaeohydrogeochemical and present evolution of groundwater in the crystalline bedrock of the Fennoscandian Shield. Understanding current undisturbed hydrochemical conditions at the proposed repository site is important when predicting future changes in groundwater chemistry. The causes behind copper corrosion and/or bentonite degradation are of particular interest as they may jeopardise the long-term integrity of the planned SKB repository system. Thus, the following variables are considered for the hydrogeochemical site descriptive modelling: pH, Eh, sulphur species, iron, manganese, carbonate, phosphate, nitrogen species, total dissolved solids (TDS), isotopes, colloids, fulvic and humic acids and microorganisms. In addition, dissolved gases (e.g. carbon dioxide, methane and hydrogen) are of interest because of their likely participation in microbial reactions. In this series of reports, the final hydrogeochemical evaluation work of the site investigation at the Forsmark site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and university researchers with expertise in

  18. Application of comprehensive geophysical prospecting method in groundwater exploration

    Science.gov (United States)

    Yang, Fan; Gao, Pengju; Li, Dong; Ma, Hanwen; Cheng, Guoliang

    2018-01-01

    In order to solve the problem of shortage of water resources in northern Shaanxi, we selected rectangular large loop source transient electromagnetic method with high water affinity, and radioactive α measurement method which can delineate the water storage structure, comprehensive geophysical prospecting methods to look for groundwater. Algorithm has established a forward model, and compared all-time apparent resistivity in late-time apparent resistivity is better than late. We can find out the exact location of the groundwater and thus improving wells rate by comparatively using these two kinds of geophysical prospecting method. Hydrogeology drilling confirmed water inflow of a single well can be up to 40 m 3/h, it can fully cover native Domestic and Agricultural water, and provide an important basis for groundwater exploration.

  19. Rapid separation method for {sup 237}Np and Pu isotopes in large soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod L., E-mail: sherrod.maxwell@srs.go [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States); Culligan, Brian K.; Noyes, Gary W. [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States)

    2011-07-15

    A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

  20. Site-Specific Hydrogen Isotope Composition of Propane: Mass spectrometric methods, equilibrium temperature dependence, and kinetics of exchange

    Science.gov (United States)

    Xie, H.; Ponton, C.; Kitchen, N.; Lloyd, M. K.; Lawson, M.; Formolo, M. J.; Eiler, J. M.

    2016-12-01

    Intramolecular isotope ordering can constrain temperatures of synthesis, mechanisms of formation, and/or source substrates of organic compounds. Here we explore site-specific hydrogen isotope variations of propane. Statistical thermodynamic models predict that at equilibrium methylene hydrogen (-CH2-) in propane will be 10's of per mil higher in D/H ratio than methyl hydrogen (-CH3) at geologically relevant temperatures, and that this difference is highly temperature dependent ( 0.5-1 ‰/°C). Chemical-kinetic controls on site-specific D/H in propane could constrain the mechanisms, conditions and extents of propane synthesis or destruction. We have developed a method for measuring the difference in D/H ratio between methylene and methyl hydrogen in propane by gas source mass spectrometry. The data were measured using the Thermo Fisher Double Focusing Sector high resolution mass spectrometer (DFS), and involve comparison of the D/H ratios of molecular ion (C3H8+) and the ethyl fragmental ion (C2H5+). We demonstrate the accuracy and precision of this method through analysis of D-labeled and independently analyzed propanes. In the exchange experiments, propane was heated (100-200 oC) either alone or in the presence of D-enriched water (δD=1,1419 ‰ SMOW), with or without one of several potentially catalytic substrates for hours to weeks. Propane was found to exchange hydrogen with water vigorously at 200 °C in the presence of metal catalysts. In the presence of Ni catalyst, methylene hydrogen exchanges 2.5 times faster than methyl hydrogen. Hydrogen exchange in the presence of Pd catalyst is more effective and can equilibrate hydrogen isotope distribution on propane on the order of 7 days. Isotopic exchange in the presence of natural materials have also been tested, but is only measurable in the methylene group at 200 °C. High catalytic activity of Pd permits attainment of a bracketed, time-invariant equilibrium state that we use to calibrate the site

  1. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues.

    Science.gov (United States)

    Devakumar, Delan; Grijalva-Eternod, Carlos S; Roberts, Sebastian; Chaube, Shiva Shankar; Saville, Naomi M; Manandhar, Dharma S; Costello, Anthony; Osrin, David; Wells, Jonathan C K

    2015-01-01

    Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1) To generate population specific calibration equations to predict lean mass (LM) from BIA in Nepalese children aged 7-9 years. (2) To explore methodological changes that may extend the range and improve accuracy. Methods. BIA measurements were obtained from 102 Nepalese children (52 girls) using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced. Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R (2) 93%). The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42). Reducing the number of children increased the error at the tails of the weight distribution. Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  2. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues

    Directory of Open Access Journals (Sweden)

    Delan Devakumar

    2015-03-01

    Full Text Available Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA is a simple and accurate method for estimating body composition, but requires population-specific calibration equations.Objectives. (1 To generate population specific calibration equations to predict lean mass (LM from BIA in Nepalese children aged 7–9 years. (2 To explore methodological changes that may extend the range and improve accuracy.Methods. BIA measurements were obtained from 102 Nepalese children (52 girls using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced.Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R2 93%. The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42. Reducing the number of children increased the error at the tails of the weight distribution.Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  3. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats

    International Nuclear Information System (INIS)

    Zilversmit, D.B.; Hughes, L.B.

    1974-01-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ( 14 C or 3 H) and an intravenous dose of colloidal labeled cholesterol ( 3 H or 14 C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-h period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method. (U.S.)

  5. Oxygen isotopic ratio of the diatom siliceous valves: development of a new method in quantitative paleoclimatology

    International Nuclear Information System (INIS)

    Labeyrie, Laurent.

    1979-07-01

    This paper describes a new method allowing the measurement of the 18 O/ 16 O ratio of the biogenic silica oxygen, which takes into account the effects due to the organic matter and hydration water associated with this type of silica. By isotopic exchange with enriched water, we have been able to fix a treatment which eliminate all contamination and memory effects. This has permitted us to study the temperature dependance of the hydrated silica-water oxygen isotopic fractionation. As application, we present a study of the variations of the delta 18 O of fossil diatoms valves along an Equatorial Pacific sediment core covering the last 20.000 years. The results demonstrate the usefulness of the delta 18 O of the diatom silica for paleoclimatic investigations [fr

  6. Comparison of methods for separating small quantities of hydrogen isotopes from an inert gas

    International Nuclear Information System (INIS)

    Willms, R.S.; Tuggle, D.; Birdsell, S.; Parkinson, J.; Price, B.; Lohmeir, D.

    1998-03-01

    It is frequent within tritium processing systems that a small amount of hydrogen isotopes (Q 2 ) must be separated from an inert gas such as He, Ar and N 2 . Thus, a study of presently available technologies for effecting such a separation was performed. A base case and seven technology alternatives were identified and a simple design of each was prepared. These technologies included oxidation-adsorption-metal bed reduction, oxidation-adsorption-palladium membrane reactor, cryogenic adsorption, cryogenic trapping, cryogenic distillation, hollow fiber membranes, gettering and permeators. It was found that all but the last two methods were unattractive for recovering Q 2 from N 2 . Reasons for technology rejection included (1) the method unnecessarily turns the hydrogen isotopes into water, resulting in a cumbersome and more hazardous operation, (2) the method would not work without further processing, and (3) while the method would work, it would only do so in an impractical way. On the other hand, getters and permeators were found to be attractive methods for this application. Both of these methods would perform the separation in a straightforward, essentially zero-waste, single step operation. The only drawback for permeators was that limited low-partial Q 2 pressure data is available. The drawbacks for getters are their susceptibility to irreversible and exothermic reaction with common species such as oxygen and water, and the lack of long-term operation of such beds. More research is envisioned for both of these methods to mature these attractive technologies

  7. Preservation Methods Alter Carbon and Nitrogen Stable Isotope Values in Crickets (Orthoptera: Grylloidea).

    Science.gov (United States)

    Jesus, Fabiene Maria; Pereira, Marcelo Ribeiro; Rosa, Cassiano Sousa; Moreira, Marcelo Zacharias; Sperber, Carlos Frankl

    2015-01-01

    Stable isotope analysis (SIA) is an important tool for investigation of animal dietary habits for determination of feeding niche. Ideally, fresh samples should be used for isotopic analysis, but logistics frequently demands preservation of organisms for analysis at a later time. The goal of this study was to establish the best methodology for preserving forest litter-dwelling crickets for later SIA analysis without altering results. We collected two cricket species, Phoremia sp. and Mellopsis doucasae, from which we prepared 70 samples per species, divided among seven treatments: (i) freshly processed (control); preserved in fuel ethanol for (ii) 15 and (iii) 60 days; preserved in commercial ethanol for (iv) 15 and (v) 60 days; fresh material frozen for (vi) 15 and (vii) 60 days. After oven drying, samples were analyzed for δ15N, δ13C values, N(%), C(%) and C/N atomic values using continuous flow isotope ratio mass spectrometry. All preservation methods tested, significantly impacted δ13C and δ15N and C/N atomic values. Chemical preservatives caused δ13C enrichment as great as 1.5‰, and δ15N enrichment as great as 0.9‰; the one exception was M. doucasae stored in ethanol for 15 days, which had δ15N depletion up to 1.8‰. Freezing depleted δ13C and δ15N by up to 0.7 and 2.2‰, respectively. C/N atomic values decreased when stored in ethanol, and increased when frozen for 60 days for both cricket species. Our results indicate that all preservation methods tested in this study altered at least one of the tested isotope values when compared to fresh material (controls). We conclude that only freshly processed material provides adequate SIA results for litter-dwelling crickets.

  8. Preservation Methods Alter Carbon and Nitrogen Stable Isotope Values in Crickets (Orthoptera: Grylloidea.

    Directory of Open Access Journals (Sweden)

    Fabiene Maria Jesus

    Full Text Available Stable isotope analysis (SIA is an important tool for investigation of animal dietary habits for determination of feeding niche. Ideally, fresh samples should be used for isotopic analysis, but logistics frequently demands preservation of organisms for analysis at a later time. The goal of this study was to establish the best methodology for preserving forest litter-dwelling crickets for later SIA analysis without altering results. We collected two cricket species, Phoremia sp. and Mellopsis doucasae, from which we prepared 70 samples per species, divided among seven treatments: (i freshly processed (control; preserved in fuel ethanol for (ii 15 and (iii 60 days; preserved in commercial ethanol for (iv 15 and (v 60 days; fresh material frozen for (vi 15 and (vii 60 days. After oven drying, samples were analyzed for δ15N, δ13C values, N(%, C(% and C/N atomic values using continuous flow isotope ratio mass spectrometry. All preservation methods tested, significantly impacted δ13C and δ15N and C/N atomic values. Chemical preservatives caused δ13C enrichment as great as 1.5‰, and δ15N enrichment as great as 0.9‰; the one exception was M. doucasae stored in ethanol for 15 days, which had δ15N depletion up to 1.8‰. Freezing depleted δ13C and δ15N by up to 0.7 and 2.2‰, respectively. C/N atomic values decreased when stored in ethanol, and increased when frozen for 60 days for both cricket species. Our results indicate that all preservation methods tested in this study altered at least one of the tested isotope values when compared to fresh material (controls. We conclude that only freshly processed material provides adequate SIA results for litter-dwelling crickets.

  9. A Comparison of Marmosa xerophilla home ranges as determined by isotope and live trap methods

    International Nuclear Information System (INIS)

    Thielen D; Arends, A.; Lea, D.

    1995-01-01

    Non breeder females of Marmosa xerophilla home ranges were determined by two methods: The first one, to which we have called isotope marked - localization method (MLR), involve the marked of three individuals with sealed radioactive sources of I-131 of 2 mCi, which were subcutaneously implanted in the back of the animals. During the 40 following days, the individuals were located in their burrows with the help of an Geiger-Muller counter. The vital areas were studied from the polygons that result from the union of the burrows more external points up to [es

  10. Contribution to research on the isotopic exploration of the lacrimal ducts

    International Nuclear Information System (INIS)

    Vauthier, Michel.

    1976-01-01

    With the help of radioactive tracers the physiological exploration of tear flow is now possible without instrumental manipulation. The use of sodium pertechnetate (sup(99m)TcO 4 -Na + ) in physiological serum solution gives a good account of the natural role of tears in the drainage system and the dynamics of this latter. A solution of radioactive sodium pertechnetate in artificial tears (9/000 solution of sodium chloride) contains very little dissolved element compared with the amount of sodium chloride present. The specific activity of the pertechnetate in saline solution varies according to the examinations between 7 and 10mCi/cm 3 , which means that each calibrated 15 μl drop has an activity of 105 to 150 μCi. The radiation dose delivered to the crystalline lens of both eyes (4mrad) is less than 2% that of an anteroposterior skull X-ray. The aim of this study is actually threefold: - in vivo demonstration of the normal internal configuration of tear ducts; - determination of the physiological lacrimal function of exccretion by qualitative and quantitative lacrimal scintigraphy, and of drainage dynamics norms; - study of tear absorption by the mucous membranes of the drainage ducts. The results show that the scintigraphic examination, while giving a mere approach to the internal morphology of the tear ducts, provides important information on their drainage dynamics [fr

  11. A double isotope dilution method for assaying of polycyclic aromatic hydrocarbons in cigarette smoke condensate

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Chen, B.T.

    1988-01-01

    This report describes a double isotope dilution method for analysis of the polycyclic aromatic hydrocarbons (PAH) phenanthrene, fluor-anthene, pyrene, and benzo[a]pyrene in cigarette smoke particulates. The first isotope dilution used deuterated analogues of the first three PAH as internal standards. The second isotope dilution, for benzo[a]pyrene, used the tritiated analogue as an internal standard. The PAH were isolated from extracts of cigarette smoke particulates using a two-step procedure based on selective extraction from aqueous dimethyl sulfoxide (DMSO) followed by chromatography on silica gel extraction columns. After isolation, aliquots of the samples were analyzed for phenanthrene, pyrene, and fluoranthene by gas chromatography with mass spectrometric detection (GC/MS). Separate aliquots of the samples were analyzed for benzo[a]pyrene by high pressure liquid chromatography with fluorescence detection followed by liquid scintillation spectrometry. PAH levels from cigarette smoke condensates collected from different exposure modes were compared; no exposure-related differences were found. (author)

  12. Determination of phosphorus in urban sewage sludge using the isotopic exchange kinetics method

    International Nuclear Information System (INIS)

    Rojas de Tramontini, Susana; Barbaro, Nestor O.; Lopez, Silvia C.

    1999-01-01

    The aim of this work was to assess the differences among soil available P, the use by the plants of sludge P, and of a water soluble fertilizer (Ca(H 2 PO 4 ) 2 ) P, using isotopic exchange kinetics methods. The sludge was provided by the Sewage Sludge Treatment Plant of Tucuman City, Argentina. The isotopic exchange kinetics experiment, in which the fate of carrier free 32 PO 4 added to the soil solution at a steady state was studied, gives information on soil P exchangeability. The experiment was carried out in the laboratory, where sewage sludge and water soluble fertilizer were added to soil samples taken at a depth of 0-25 and 25-40 cm. Changes in the soil P isotopically exchangeable within 1 minute measurements in the soil with sludge and in the soil with water soluble fertilizer showed that the 0-25 cm deep soil samples had a low P sorption capacity (r1 /R values were low). The sludge had high total and organic P, but the P in the soil solution was lower than the P provided by the water soluble fertilizer. Therefore, despite its higher total P content, this sludge contained slow available forms of P

  13. Isothermal and non-isothermal conditions of isotope separation by chemical exchange method

    International Nuclear Information System (INIS)

    Khoroshilov, A.V.; Andreev, B.M.; Katalnikov, S.G.

    1992-01-01

    The published data about the effect of temperature on thermodynamic and mass transfer parameters of isotope separation by the chemical exchange method were used to examine the influence of iso- and non-isothermal conditions on the effectiveness of the separation process. It has been shown that simultaneous fulfillment of several optimization criteria is impossible in optimization of the isothermal process. If the limitation that temperature must be constant in the whole range of concentrational changes for an isolated isotope is removed, then it is possible to solve the problem of optimization with simultaneous fulfillment of several optimization criteria. When the separation process is carried out with non-isothermal conditions, that is, in temperature cascade, then the maximum concentration change takes place at every theoretical separation plate, and whole cascade is characterised by maximum throughput, minimum height and volume, and minimum cost for the stream reflux. From the results of our study, it was concluded that in the optimum temperature cascade, the cost of production of unity quantity of isotope can be decreased at least by a factor of two as compared with the optimal isothermal version of the separation process. (author)

  14. Method for determination of stable carbon isotope ratio of methylnitrophenols in atmospheric particulate matter

    Directory of Open Access Journals (Sweden)

    S. Moukhtar

    2011-11-01

    Full Text Available A technique for the measurement of the stable isotope ratio of methylnitrophenols in atmospheric particulate matter is presented. Atmospheric samples from rural and suburban areas were collected for evaluation of the procedure. Particulate matter was collected on quartz fibre filters using dichotomous high volume air samplers. Methylnitrophenols were extracted from the filters using acetonitrile. The sample was then purified using a combination of high-performance liquid chromatography and solid phase extraction. The final solution was then divided into two aliquots. To one aliquot, a derivatising agent, Bis(trimethylsilyltrifluoroacetamide, was added for Gas Chromatography-Mass Spectrometry analysis. The second half of the sample was stored in a refrigerator. For samples with concentrations exceeding 1 ng μl−1, the second half of the sample was used for measurement of stable carbon isotope ratios by Gas Chromatography-Isotope Ratio Mass Spectrometry.

    The procedure described in this paper provides a method for the analysis of methylnitrophenols in atmospheric particulate matter at concentrations as low as 0.3 pg m−3 and for stable isotope ratios with an accuracy of better than ±0.5‰ for concentrations exceeding 100 pg m−3.

    In all atmospheric particulate matter samples analysed, 2-methyl-4-nitrophenol was found to be the most abundant methylnitrophenol, with concentrations ranging from the low pg m−3 range in rural areas to more than 200 pg m−3 in some samples from a suburban location.

  15. A Method of Trajectory Design for Manned Asteroids Exploration

    Science.gov (United States)

    Gan, Q. B.; Zhang, Y.; Zhu, Z. F.; Han, W. H.; Dong, X.

    2014-11-01

    A trajectory optimization method of the nuclear propulsion manned asteroids exploration is presented. In the case of launching between 2035 and 2065, based on the Lambert transfer orbit, the phases of departure from and return to the Earth are searched at first. Then the optimal flight trajectory in the feasible regions is selected by pruning the flight sequences. Setting the nuclear propulsion flight plan as propel-coast-propel, and taking the minimal mass of aircraft departure as the index, the nuclear propulsion flight trajectory is separately optimized using a hybrid method. With the initial value of the optimized local parameters of each three phases, the global parameters are jointedly optimized. At last, the minimal departure mass trajectory design result is given.

  16. Advances in Airborne and Ground Geophysical Methods for Uranium Exploration

    International Nuclear Information System (INIS)

    2013-01-01

    through the use of effective exploration techniques. Geophysical methods with the capability of mapping surface and subsurface parameters in relation to uranium deposition and accumulation are proving to be vital components of current exploration efforts around the world. There is continuous development and improvement of technical and scientific disciplines using measuring instruments and spatially referenced data processing techniques. Newly designed geophysical instruments and their applications in uranium exploration are contributing to an increased probability of successful discoveries. Dissemination of information on advances in geophysical techniques encourages new strategies and promotes new approaches toward uranium exploration. Meetings and conferences organized by the IAEA, collecting the experience of participating countries, as well as its publications and the International Nuclear Information System, play an important role in the dissemination of knowledge of all aspects of the nuclear fuel cycle. The purpose of this report is to highlight advances in airborne and ground geophysical techniques, succinctly describing modern geophysical methods and demonstrating the application of techniques through examples. The report also provides some basic concepts of radioactivity, nuclear radiation and interaction with matter.

  17. Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness.

    Science.gov (United States)

    Heckel, Benjamin; Rodríguez-Fernández, Diana; Torrentó, Clara; Meyer, Armin; Palau, Jordi; Domènech, Cristina; Rosell, Mònica; Soler, Albert; Hunkeler, Daniel; Elsner, Martin

    2017-03-21

    Compound-specific chlorine isotope analysis of tetrachloromethane (CCl 4 ) and trichloromethane (CHCl 3 ) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl 3 , CCl 2 , CCl (of CCl 4 ) and CHCl 3 , CHCl 2 , CHCl (of CHCl 3 ), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35 Cl- to 37 Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2‰ (CHCl 3 ) and 0.4‰ (CCl 4 ), which are only about twice as large as 0.1‰ and 0.2‰ for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl 4 and CHCl 3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl 4 and CHCl 3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.

  18. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  19. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  20. Evaluation for dinitrogen fixation of induced wheat nodules by 15N isotope dilution method

    International Nuclear Information System (INIS)

    Yao Yunyin; Zhen Ming; Chang Xizhong

    1993-11-01

    The results in pot experiments showed that the treating of 2,4-D and Azorhizobium caulinodans (2,4-D+A) could induce para-nodule formation on wheat roots. Plants treated grew normally. The plant height and dry weight are significantly higher than reference plants which are treated with 2,4-D+azorhizobium sterilized (2,4-D+AS). The nitrogenase activity is detected by ARA method. The N yield of most treated plants, especially in root systems, is higher than reference group that is measured by Kjeldahl method. The atom % 15 N excess in leaf and stem of treated plants measured by 15 N isotope dilution method is lower than that of reference group. Through four years experiments, it shows that para-nodules of wheat treated with 2,4-D+A could fix N 2 from air, but the ability of nitrogen fixation is lower and unstable. Although the nodulation efficiency could reach 100%, not each para-nodule induced can present activity of dinitrogen fixation. The amount of N fixed is 0.05∼18.1 mg/pot (0.01∼3.87 mg/plant). The net %Ndfa is 2.32%∼18.07%. The free-living N 2 fixing activity of azorhizobium is detected by 15 N isotope dilution method. The calculation of %Ndfa of nodulated wheat accurately is also discussed

  1. Speciative determination of phosphorus in environmental water by the isotope exchange method

    International Nuclear Information System (INIS)

    Ikeda, N.; Yoshikawa, M.; Murakami, S.; Kunika, J.

    1988-01-01

    An isotope exchage method for the speciative determination of phosphorus (PO 4 3- ,PO 3 3- and total P) in natural water samples is proposed by using the exchange system of molybdophosphate in the aqueous phase and tetraphenylarsonium molybdophosphate in the organic phase. In this exchange system, only PO 4 3- exchanges and is determined. When the sample water is treated with Br 2 water in advance, the amount of PO 4 3- +PO 3 3- can be obtained. When the sample is treated with H 2 SO 4 and HNO 3 , the amount of total P can be determined. (author) 4 refs.; 5 tabs

  2. Application of the generator coordinate method to neutron-rich Se and Ge isotopes

    Directory of Open Access Journals (Sweden)

    Higashiyama Koji

    2014-03-01

    Full Text Available The quantum-number projected generator coordinate method (GCM is applied to the neutron-rich Se and Ge isotopes, where the monopole and quadrupole pairing plus quadrupole-quadrupole interaction is employed as an effective interaction. The energy spectra obtained by the GCM are compared to both the shell model results and the experimental data. The GCM reproduces well the energy levels of high-spin states as well as the low-lying states. The structure of the low-lying collective states is analyzed through the GCM wave functions.

  3. Development of precise analytical methods for strontium and lanthanide isotopic ratios using multiple collector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ohno, Takeshi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2007-01-01

    We have developed precise analytical methods for strontium and lanthanide isotopic ratios using multiple collector-ICP-mass spectrometry (MC-ICP-MS) for experimental and environmental studies of their behavior. In order to obtain precise isotopic data using MC-ICP-MS, the mass discrimination effect was corrected by an exponential law correction method. The resulting isotopic data demonstrated that highly precise isotopic analyses (better than 0.1 per mille as 2SD) could be achieved. We also adopted a de-solvating nebulizer system to improve the sensitivity. This system could minimize the water load into the plasma and provided about five times larger intensity of analyte than a conventional nebulizer system did. (author)

  4. The use of trace element data to complement stable isotope methods in the characterization of grape musts

    International Nuclear Information System (INIS)

    Day, M.P.; Zhang, B.L.; Martin, G.J.

    1994-01-01

    Objective physico-chemical methods for the characterization of agricultural produce are important ways of providing impartial information on the composition and origin of food products. Of those techniques successful in this area, stable isotope analyses and especially Site Specific Natural Isotope Fractionation studied by nuclear magnetic resonance (SNIF-NMR) are among the most noteworthy. The use of this technique allows the determination of geographical origin of a variety of finished and raw materials in the food industry. The current capabilities of this technique in the wine industry allow the general area of production to be determined. Trace element concentrations have been analyzed for five regions of France (1989 vintage) in order to improve the accuracy of the SNIF-NMR method. When used in conjunction with stable isotope ratios, the elements Zn, Ca, Sr, and Mg increase the overall classification from 78% (with isotope data only) to 89%. (author)

  5. Exploring the Potential of Laser Ablation Carbon Isotope Analysis for Examining Ecology during the Ontogeny of Middle Pleistocene Hominins from Sima de los Huesos (Northern Spain).

    Science.gov (United States)

    Garcia, Nuria; Feranec, Robert S; Passey, Benjamin H; Cerling, Thure E; Arsuaga, Juan Luis

    2015-01-01

    Laser ablation of tooth enamel was used to analyze stable carbon isotope compositions of teeth of hominins, red deer, and bears from middle Pleistocene sites in the Sierra de Atapuerca in northern Spain, to investigate the possibility that this technique could be used as an additional tool to identify periods of physiological change that are not detectable as changes in tooth morphology. Most of the specimens were found to have minimal intra-tooth variation in carbon isotopes (< 2.3‰), suggesting isotopically uniform diets through time and revealing no obvious periods of physiological change. However, one of the two sampled hominin teeth displayed a temporal carbon isotope shift (3.2‰) that was significantly greater than observed for co-occurring specimens. The δ13C value of this individual averaged about -16‰ early in life, and -13‰ later in life. This isotopic change occurred on the canine crown about 4.2 mm from the root, which corresponds to an approximate age of two to four years old in modern humans. Our dataset is perforce small owing to the precious nature of hominid teeth, but it demonstrates the potential utility of the intra-tooth isotope profile method for extracting ontogenetic histories of human ancestors.

  6. A Signal Processing Method to Explore Similarity in Protein Flexibility

    Directory of Open Access Journals (Sweden)

    Simina Vasilache

    2010-01-01

    Full Text Available Understanding mechanisms of protein flexibility is of great importance to structural biology. The ability to detect similarities between proteins and their patterns is vital in discovering new information about unknown protein functions. A Distance Constraint Model (DCM provides a means to generate a variety of flexibility measures based on a given protein structure. Although information about mechanical properties of flexibility is critical for understanding protein function for a given protein, the question of whether certain characteristics are shared across homologous proteins is difficult to assess. For a proper assessment, a quantified measure of similarity is necessary. This paper begins to explore image processing techniques to quantify similarities in signals and images that characterize protein flexibility. The dataset considered here consists of three different families of proteins, with three proteins in each family. The similarities and differences found within flexibility measures across homologous proteins do not align with sequence-based evolutionary methods.

  7. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Directory of Open Access Journals (Sweden)

    J. D. Hemingway

    2017-11-01

    Full Text Available Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E, a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  8. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Science.gov (United States)

    Hemingway, Jordon D.; Rothman, Daniel H.; Rosengard, Sarah Z.; Galy, Valier V.

    2017-11-01

    Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC) chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E), a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO) analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  9. Chemical and isotopic methods for characterization of pollutant sources in rain water

    International Nuclear Information System (INIS)

    Verma, M.P.

    1996-01-01

    The acid rain formation is related with industrial pollution. An isotopic and chemical study of the spatial and temporary distribution of the acidity in the rain gives information about the acidity source. The predominant species in the acid rain are nitrates and sulfates. For the rain monitoring is required the determination of the anion species such as HCO 3 , Cl, SO 4 , NO 3 and p H. So it was analyzed the cations Na + , K + , Ca 2+ and Mg 2+ to determine the quality analysis. All of them species can be determined with enough accuracy, except HCO 3 by modern equipment such as, liquid chromatograph, atomic absorption, etc. The HCO 3 concentration is determined by traditional methods like acid-base titration. This work presents the fundamental concepts of the titration method for samples with low alkalinity (carbonic species), for rain water. There is presented a general overview over the isotopic methods for the characterization of the origin of pollutant sources in the rain. (Author)

  10. Measurement of plant and soil water isotope composition by direct equilibration methods

    Science.gov (United States)

    Scrimgeour, C. M.

    1995-11-01

    Water contained in plant and soil samples can be analysed for 2H and 18O content by direct equilibration while contained within the sample matrix. Methods for this are described and compared with the commonly used azeotropic distillation of samples before isotope analysis. For δ18O, direct equilibration with CO 2 gives results in good agreement with azeotropic distillation, i.e. within 0.5%o at natural abundance. Direct equilibration is a practical method for individual twig samples containing less than 0.5 ml of water, and offers significant operator time savings compared with azeotropic distillation. Batches of up to 100 samples can be prepared in less time than required for a single azeotropic distillation, and analysis by automated continuous-flow isotope ratio mass spectrometry after equilibration for 3 days again requires a minimum of operator time. Complete equilibration of plant water with H 2 for δ2H measurement occurs only after the plant material has been heated to 100°C under vacuum. The method described here is barely precise enough for natural abundance measurements ( δ 2H ± 15‰ ) but is well suited to field tracer studies with deuterium oxide.

  11. Oral histories: a simple method of assigning chronological age to isotopic values from human dentine collagen.

    Science.gov (United States)

    Beaumont, Julia; Montgomery, Janet

    2015-01-01

    Stable isotope ratios of carbon (δ(13)C) and nitrogen (δ(15)N) in bone and dentine collagen have been used for over 30 years to estimate palaeodiet, subsistence strategy, breastfeeding duration and migration within burial populations. Recent developments in dentine microsampling allow improved temporal resolution for dietary patterns. A simple method is proposed which could be applied to human teeth to estimate chronological age represented by dentine microsamples in the direction of tooth growth, allowing comparison of dietary patterns between individuals and populations. The method is tested using profiles from permanent and deciduous teeth of two individuals. Using a diagrammatic representation of dentine development by approximate age for each human tooth (based on the Queen Mary University of London Atlas), this study estimated the age represented by each dentine section. Two case studies are shown: comparison of M1 and M2 from a 19th century individual from London, England, and identification of an unknown tooth from an Iron Age female adult from Scotland. The isotopic profiles demonstrate that variations in consecutively-forming teeth can be aligned using this method to extend the dietary history of an individual or identify an unknown tooth by matching the profiles.

  12. Applicability of isotopic dilution methods for determination of the zinc supplying capacity of some Indian soils

    International Nuclear Information System (INIS)

    Iyengar, B.R.V.; Deb, D.L.

    1975-01-01

    The applicability of the isotopic dilution methods to determine the zinc supplying capacity of some Indian soils belonging to three soil groups was studied using 65 Zn. In these soils 'L' values determined by the pot culture method and the 'E' values by equilibration in soil suspensions by the carrier free and carrier methods and using chemical extractants DTPA-CaCl 2 -NaOAc and EDTA-NH 4 OAc were compared. The 'L' values were significantly correlated with zinc uptake by maize and also with zinc extracted by a number of chemical extractants. The laboratory determinations 'E' values by isotopic exchange equilibria in soil suspension both with and without carrier zinc led to over estimates and gave grossly exggerated values of 'labile zinc' especially in alkaline and high zinc 'fixing' soils. The 'E' values determined in both DTPA-CaCl 2 -NaOAc and EDTA-NH 4 OAc correlated significantly with zinc uptake by maize. These values agreed well with 'L' values and 'available' zinc determined by chemical soil tests. (author)

  13. Isotope enrichment

    International Nuclear Information System (INIS)

    Garbuny, M.

    1979-01-01

    The invention discloses a method for deriving, from a starting material including an element having a plurality of isotopes, derived material enriched in one isotope of the element. The starting material is deposited on a substrate at less than a critical submonatomic surface density, typically less than 10 16 atoms per square centimeter. The deposit is then selectively irradiated by a laser (maser or electronic oscillator) beam with monochromatic coherent radiation resonant with the one isotope causing the material including the one istope to escape from the substrate. The escaping enriched material is then collected. Where the element has two isotopes, one of which is to be collected, the deposit may be irradiated with radiation resonant with the other isotope and the residual material enriched in the one isotope may be evaporated from the substrate and collected

  14. Isotope separation

    International Nuclear Information System (INIS)

    Bartlett, R.J.; Morrey, J.R.

    1978-01-01

    A method and apparatus is described for separating gas molecules containing one isotope of an element from gas molecules containing other isotopes of the same element in which all of the molecules of the gas are at the same electronic state in their ground state. Gas molecules in a gas stream containing one of the isotopes are selectively excited to a different electronic state while leaving the other gas molecules in their original ground state. Gas molecules containing one of the isotopes are then deflected from the other gas molecules in the stream and thus physically separated

  15. Exploration Method Development for hydrothermal plume hunting by XCTD

    Science.gov (United States)

    Kitagawa, Y.; Ikeda, M.; Kadoshima, K.; Koizumi, Y.; Nakano, J.; Asakawa, E.; Sumi, T.

    2017-12-01

    J-MARES (Research and Development Partnership for Next Generation Technology of Marine Resources Survey, JAPAN) has been designing a low-cost and high-efficiency exploration system for seafloor hydrothermal massive sulfide deposits in "Cross-ministerial Strategic Innovation Promotion Program (SIP)" granted by the Cabinet Office, Government of Japan since 2014. We proposed hydrothermal plume hunting by XCTD (eXpendables Conductivity, Temperature and Depth). We applied this method to an area of interest more than 100km x 100km over Okinawa Trough, including some known seafloor massive sulfide deposits. Generally, hydrothermal plume exploration has been by ship mounted with MBES (Multi Beam Echo Sounder) or AUV with sound anomaly observation. However, these methods have to charter the sophisticated ship costly. On the other hand, throw-in type water quality meters (eg. XCTD and XBT) can be low-cost and easily operable. Moreover, that can make a quick look at seawater temperature and conductivity even in rough waters.Firstly, we confirmed XCTD probes position on the seafloor by ROV mounted deep-sea high vision camera. As a result of the test, probes swept downstream about 40 m in horizontal distance from throwing positions with about 1,600m in water depth. Following the previous test results, we had performed to the next test that confirmed detection range of hydrothermal plume at the chimney of North Mound in Izena Cauldron, so we had caught anomaly of seawater temperature and conductivity successfully which could be possibly derived from hydrothermal activities. Although averaged seawater temperature at a depth of 1500 m or more was about 3.95 degrees C, near the chimney was about 4.93 degrees C. The temperature anomalies originated from the hydrothermal plumes could be distributed at most 30m in horizontal distance and became smaller away from the chimney. Moreover, temperature anomaly mass of sea water tended to move upward in depth with distance away from the

  16. Isotopic methods of investigations of hydrodynamics in installations for hydrometallurgic processing of copper concentrates

    International Nuclear Information System (INIS)

    Stsheletski, M.; Urban'ski, T.S.

    1979-01-01

    Isotope methods have been presented of investigations of hydrodynamics of liquid and solid phases in pilot-scale installations for hydrometallurgic processing of copper concentrates: in the column installation for leaching; in the tubular reactor for copper reduction by hydrogen and in the installation for crystallization of magnesium sulphate under pressure conditions. The column leaching installation has been tested by pulse injection of two radioisotope indicators simultaneously. The copper concentrate was labelled by sorbed colloidal gold-198 and the liquid phase was labelled by solution of sodium chloride containing sodium-24. Measurements of the radiation intensities were registered by scintillation counters, working with a single-channel amplitude analyzer, integrators and counting rate monitors. According to the distribution of time of stay, by the moments method, number of powers of ideal intermixings in the cell model of flow of the both phases. In the tubular reactor process of copper reduction by hydrogen is going on in three phases: gas-liquid-solig phase. Hydrodynamic investigations in this instalation was done in the presence of air, water and copper powder. Water was labelled by sodium-24 and copper powder by copper-64. Changes of intensity of radiation were measured by scintillation counters, located along the installation and were registered by multichannel amplitude analyzer. Peckle number and longitudal dispersion factor were determined. In investigations of the solid phase hydrodynamics during crystallization of magnesium sulphate under elevated temperature and high pressure, as an indicator, isotope gold-198 has been used, by which crystalls of the solid phase were labelled, and isotope sodium-24 was added to a liquid. Simultaneousely were measured and registered by a single-channel analyzer intensity of radiation of both indicators. Mean time of stay and parameters of a mathematical model of the phases flow in this installation were

  17. Evaluation of nitrogen utilization efficiency by corn (Zea mays, L.) using the isotopic and difference methods, under field conditions

    International Nuclear Information System (INIS)

    Calvache, U.M.

    1984-01-01

    Randomized brocks design, with three replicates, using two contribuids (C-111 X and C-511) and seven sampling times (15, 30, 45, 60, 75, 120 and 150 days after germination) are presented. 15 N-urea is applied at a rate of 100 Kg N-ha -1 and two methods [isotopic and no isotopic] are used to calculate the fertilizer use efficiency. (M.A.C.) [pt

  18. An easy method for the determination of Ra isotopes and actinide alpha emitters from the same water sample

    International Nuclear Information System (INIS)

    Moron, M.C.; Garcia-Tenorio, R.; Garcia-Montano, E.; Garcia-Leon, M.; Madurga, G.

    1986-01-01

    Radium isotopes and actinide α emitters are easily determined from the same water sample. The Ra fraction is obtained by coprecipitation with Ba, while a Fe coprecipitation is used for the actinides. Both fractions are measured with a gas-flow proportional counter. Additionally the isotopic Ra composition is obtained by measuring at two or three different times the α activity from the Ra-fraction. The method is applied to rain water and drinking water samples. (author)

  19. Development and validation of an analytical method for the determination of lead isotopic composition using ICP-QMS

    OpenAIRE

    Rodríguez-Salazar, M. T.; Morton Bermea, O.; Hernández-Álvarez, E.; García-Arreola, M. E.; Ortuño-Arzate, M. T.

    2010-01-01

    This work reports a method for the precise and accurate determination of Pb isotope composition in soils and geological matrices by ICP-QMS. Three reference materials (AGV-2, SRM 2709 and JSO-1) were repeatedly measured, using ICP-QMS instruments in order to assess the quality of this analytical procedure. Mass discrimination was evaluated for Pb/Pb with Pb isotope reference material NIST SRM 981, and the correction applied to the above mentioned reference materials to achieve good accuracy o...

  20. A virtual component method in numerical computation of cascades for isotope separation

    International Nuclear Information System (INIS)

    Zeng Shi; Cheng Lu

    2014-01-01

    The analysis, optimization, design and operation of cascades for isotope separation involve computations of cascades. In analytical analysis of cascades, using virtual components is a very useful analysis method. For complicated cases of cascades, numerical analysis has to be employed. However, bound up to the conventional idea that the concentration of a virtual component should be vanishingly small, virtual component is not yet applied to numerical computations. Here a method of introducing the method of using virtual components to numerical computations is elucidated, and its application to a few types of cascades is explained and tested by means of numerical experiments. The results show that the concentration of a virtual component is not restrained at all by the 'vanishingly small' idea. For the same requirements on cascades, the cascades obtained do not depend on the concentrations of virtual components. (authors)

  1. Method for determination of radioactive iodine isotopes in environmental objects and biologic materials

    International Nuclear Information System (INIS)

    Dubynin, O.D.; Pogodin, R.I.

    1981-01-01

    The method proposed for determination of radioactive iodine isotopes content in environmental objects and biologic materials is based on the extraction of iodine with carbon tetrachloride and subsequent precipitation of bismuthyl iodine (BiOI) in perchloric medium. Sample preparation for analysis is carried out using conventional alkaline ashing methods. Quantitative iodine separation is hampered if macroquantities of Cl - , Br - , SO 4 2 - , SO 8 2 - , Cr 2 O 7 2 - and other ions are present in the solution. Iodine extraction is carried out before its precipitation. Separated iodine preparation activity is measured using scintillation (NaI) Tl gamma spectrometer. The method's sensitivity when measuring iodine-131 preparations makes up 0.07 Bq per 1 sample with the error +-25 %

  2. Double isotopic method using dansyl chloride for the determination of GABA in rat C6 astrocytoma cell cultures

    Energy Technology Data Exchange (ETDEWEB)

    Kohl, R.L.; Quay, W.B.; Perez-Polo, J.R.

    1986-01-01

    Methods are described for the quantitative measurement of GABA in culture. The method can be adapted to any amino acid or dansyl-chloride-reactive species. The sensitivity and selectivity of the procedure result from the double isotopic design in which (/sup 14/C)-labeled internal standard was added to the samples before reaction with (3M)-labeled dansyl chloride. Values obtained by ion-exchange amino acid analysis of cultures agree closely with the values obtained by the double isotopic method. This method is sensitive enough to measure GABA intracellularly and the condition medium.

  3. Quantitative determination of nitrogen biological fixation by the N-15 isotopic method

    International Nuclear Information System (INIS)

    Basantes, Emilio; Trivelin, Paulo; Mui Tsai, Siu

    1993-01-01

    In order to quantify the biological nitrogen fixation (BNF) and to evaluate the mycorrhiza effect in the BNF, an experiment was carried on by applying 1 5 N -ammonium sulphate and mycorrhiza fungi to the soil. The treatments included legumes: mucuna negra(Stizolobium atterrinum Piper et Tracv) and caupi (Vigna unguiculoata L. Walp). Two control plants: non nodulating soybean (Glycine max L.Merril) and rice (Oryza sativa), were used for measuring the fixed N in the legumes by isotope dilution method. Both legumes and control plants assimmilated the same ammounts of nitrogen from the soil and fertilizer. The greater N content in the legumnes was determined as coming from the fixed nitrogen. Rice and non nodulating soybean showed to be good controls for measuring biological nitrogen fixation using isotopic dilution method. The values of fixed nitrogen for legumes calculated using rice as control plant were slightly greater than those with non nodulating soybean, nevertheless there were no significant statistical differences between the values. The mucuna fixed more N than caupi in both mycorrhiza treatments (76.7, 66.6 and 56. 7 per cent of N fixed, respectively). The mycorrhiza increased dry matter yield (13.84 per cent), accumulation of N in the plant(14.85 per cent N) and the biological N fixation (16.06 per cent N-fixed) in caupi

  4. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  5. Methods for the exploration and recovering of uranium

    International Nuclear Information System (INIS)

    Kegel, K.E.

    1982-01-01

    The uranium reserves in the western world occur basically in two types of deposits a) vein type and vein like types b) sedimentary types, with the vein deposits providing only 5 percent of the actual uranium production. 85% of the known uranium reserves in the western world, amounting to about 5 million metric tons U occur in a relatively small number of countries (U.S.A., Canada, Australia, South Africa and Namibia, France, Niger and Gabun). Exploration on uranium deposits is carried out by using geophysical and geochemical methods. Radiometry, i.e. the determination of the radioactivity of the ground in a prospective area, is the main geophysical tool. In the mining of uranium ores, practically all mining methods, applied in other metal mining branches, are being used. The benefication of uranium ore is characterized by a large up-grading factor (i.e. the ratio between the uranium content in the concentrates and the uranium content in the ore) which is higher than in most other metal mining operations. In the field of health and safety in uranium mines, the radiation protection of the workers plays a paramount role. Strict rules exist for maximum values of certain elements in waste air and waste water of uranium mining operations, emitted into the environment. (orig.)

  6. Exploration of Stellarator Configuration Space with Global Search Methods

    International Nuclear Information System (INIS)

    Mynick, H.E.; Pomphrey, N.; Ethier, S.

    2001-01-01

    An exploration of stellarator configuration space z for quasi-axisymmetric stellarator (QAS) designs is discussed, using methods which provide a more global view of that space. To this end, we have implemented a ''differential evolution'' (DE) search algorithm in an existing stellarator optimizer, which is much less prone to become trapped in local, suboptimal minima of the cost function chi than the local search methods used previously. This search algorithm is complemented by mapping studies of chi over z aimed at gaining insight into the results of the automated searches. We find that a wide range of the attractive QAS configurations previously found fall into a small number of classes, with each class corresponding to a basin of chi(z). We develop maps on which these earlier stellarators can be placed, the relations among them seen, and understanding gained into the physics differences between them. It is also found that, while still large, the region of z space containing practically realizable QAS configurations is much smaller than earlier supposed

  7. Integrated use of soil physical and water isotope methods for ecohydrological characterization of desertified areas

    Science.gov (United States)

    Külls, Christoph; Nunes, Alice; Köbel-Batista, Melanie; Branquinho, Cristina; Bianconi, Nadja; Costantini, Eduardo

    2014-05-01

    marked decrease in water permeability at 0.04, 0.20, or 0.40 m depth. Soil isotope profiles indicated that percolation beneath the root zone and groundwater recharge ranges from 21.7 mm/y to 29.7 mm/y. The recharge rate was positively related to mean annual rainfall and soil organic matter, and interestingly, increased with aridity and desertification. The difference between mean annual rainfall and percolation was positively related to plant cover and in inverse proportion to the aridity index. Our results highlight the importance of combining different methods of site characterization by soil physics, soil water isotopes and soil water chemistry (chloride) with vegetation data, providing a more specific analysis of ecohydrological conditions and their relation to ecosystem functioning and recovery potential. The field protocol applied can provide relevant information for guiding restoration strategies. Costantini, E. A. C., Urbano, F., Aramini, G., Barbetti, R., Bellino, F., Bocci, M., & Tascone, F. (2009). Rationale and methods for compiling an atlas of desertification in Italy. Land Degradation & Development, 20(3), 261-276. Garvelmann, J., Külls, C., & Weiler, M. (2012). A porewater-based stable isotope approach for the investigation of subsurface hydrological processes. Hydrology and Earth System Sciences, 16(2), 631-640.

  8. Application of organic-geochemistry, coal-petrology and isotope-geochemistry to facies-analysis and hydrocarbon exploration in the NE-Paris Basin (Trias-Lias Luxemburg)

    International Nuclear Information System (INIS)

    Flekken, P.M.

    1978-01-01

    Triassic and Liassic sediments of NE-Paris Basin (Luxemburg) were investigated by organic-geochemical, coal petrographical and isotope-geochemical methods. The objective was to characterize the stratigraphic stages and to investigate the facies relations between them with a view to possible hydrocarbon exploration. The sediments contain an average of 3.1% organic carbon, 413 ug/g extractable organic matter (bitumen) and 0.65% insoluble, isolatable organic particles which constitute part of the kerogen. The non-isolatable kerogen is 2.4% of the whole rock. (orig./BR) [de

  9. Mercury speciation analysis in seafood by species-specific isotope dilution: method validation and occurrence data

    Energy Technology Data Exchange (ETDEWEB)

    Clemens, Stephanie; Guerin, Thierry [Agence Nationale de Securite Sanitaire de l' Alimentation, Laboratoire de Securite des Aliments de Maisons-Alfort, Unite des Contaminants Inorganiques et Mineraux de l' Environnement, ANSES, Maisons-Alfort (France); Monperrus, Mathilde; Donard, Olivier F.X.; Amouroux, David [IPREM UMR 5254 CNRS - Universite de Pau et des Pays de l' Adour, Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, Institut des Sciences Analytiques et de Physico-chimie pour l' Environnement et les Materiaux, Pau Cedex (France)

    2011-11-15

    Methylmercury (MeHg) and total mercury (THg) in seafood were determined using species-specific isotope dilution analysis and gas chromatography combined with inductively coupled plasma mass spectrometry. Sample preparation methods (extraction and derivation step) were evaluated on certified reference materials using isotopically enriched Hg species. Solid-liquid extraction, derivation by propylation and automated agitation gave excellent accuracy and precision results. Satisfactory figures of merit for the selected method were obtained in terms of limit of quantification (1.2 {mu}g Hg kg{sup -1} for MeHg and 1.4 {mu}g Hg kg{sup -1} for THg), repeatability (1.3-1.7%), intermediate precision reproducibility (1.5% for MeHg and 2.2% for THg) and trueness (bias error less than 7%). By means of a recent strategy based on accuracy profiles ({beta}-expectation tolerance intervals), the selected method was successfully validated in the range of approximately 0.15-5.1 mg kg{sup -1} for MeHg and 0.27-5.2 mg kg{sup -1} for THg. Probability {beta} was set to 95% and the acceptability limits to {+-}15%. The method was then applied to 62 seafood samples representative of consumption in the French population. The MeHg concentrations were generally low (1.9-588 {mu}g kg{sup -1}), and the percentage of MeHg varied from 28% to 98% in shellfish and from 84% to 97% in fish. For all real samples tested, methylation and demethylation reactions were not significant, except in one oyster sample. The method presented here could be used for monitoring food contamination by MeHg and inorganic Hg in the future to more accurately assess human exposure. (orig.)

  10. Continuous-flow isotope ratio mass spectrometry method for carbon and hydrogen isotope measurements on atmospheric methane

    Directory of Open Access Journals (Sweden)

    M. Brass

    2010-12-01

    Full Text Available We describe a continuous-flow isotope ratio mass spectrometry (CF-IRMS technique for high-precision δD and δ13C measurements of atmospheric methane on 40 mL air samples. CH4 is separated from other air components by utilizing purely physical processes based on temperature, time and mechanical valve switching. Chemical agents are avoided. Trace amounts of interfering compounds can be separated by gas chromatography after pre-concentration of the CH4 sample. The purified sample is then either combusted to CO2 or pyrolyzed to H2 for stable isotope measurement. Apart from connecting samples and refilling liquid nitrogen as coolant the system is fully automated and allows an unobserved, continuous analysis of samples. The analytical system has been used for analysis of air samples with CH4 mixing ratios between ~100 and ~10 000 ppb, for higher mixing ratios samples usually have to be diluted.

  11. A routine high-precision method for Lu-Hf isotope geochemistry and chronology

    Science.gov (United States)

    Patchett, P.J.; Tatsumoto, M.

    1981-01-01

    A method for chemical separation of Lu and Hf from rock, meteorite and mineral samples is described, together with a much improved mass spectrometric running technique for Hf. This allows (i) geo- and cosmochronology using the176Lu???176Hf+??- decay scheme, and (ii) geochemical studies of planetary processes in the earth and moon. Chemical yields for the three-stage ion-exchange column procedure average 90% for Hf. Chemical blanks are international mass spectrometric standard; suitable aliquots, prepared from a single batch of JMC 475, are available from Denver. Lu-Hf analyses of the standard rocks BCR-1 and JB-1 are given. The potential of the Lu-Hf method in isotope geochemistry is assessed. ?? 1980 Springer-Verlag.

  12. Possibility of determination of the Galaxy age by the method of uranium - thorium isotopic relations

    International Nuclear Information System (INIS)

    Lyutostanskij, Yu.S.; Malevannyj, S.V.; Panov, I.V.; Chechetkin, V.M.

    1988-01-01

    Calculations concerning the formation of heavy elements in an astrophysical fast nuclear process characteristics of the Supernova explosions are carried out in the kinetic model of nucleosynthesis. The age of the Galaxy T G has been calculated making use of the method of uranium-thorium isotopic relations supplemented with the data on 244 Pu abundance in meteorites. T G is shown to be strongly dependent upon the calculation method applied to production of nuclei in r process, upon the data on neutron-rich nuclei and as well upon the external conditions, i.e. the density and temperature in the explosing star. The possibility of nucleosynthesis takes place due to close Supernova explosion, which enriched the chemical content of earth matter with heavy elements is analyzed. The range of allowed values of parameters of the theory of nucleosynthesis is studied

  13. Characteristic analysis of laser isotope separation process by two-step photodissociation method

    International Nuclear Information System (INIS)

    Okamoto, Tsuyoshi; Suzuki, Atsuyuki; Kiyose, Ryohei

    1981-01-01

    A large number of laser isotope separation experiments have been performed actively in many countries. In this paper, the selective two-step photodissociation method is chosen and simultaneous nonlinear differential equations that express the separation process are solved directly by using computer. Predicted separation factors are investigated in relation to the incident pulse energy and the concentration of desired molecules. Furthermore, the concept of separative work is used to evaluate the results of separation for this method. It is shown from an example of numerical calculation that a very large separation factor can be obtained if the concentration of desired molecules is lowered and two laser pulses to be closely synchronized are not always required in operation for the photodissociation of molecules. (author)

  14. A new method for the labelling of proteins with radioactive arsenic isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Jennewein, M. [Institute of Nuclear Chemistry, Johannes Gutenberg University of Mainz, Fritz-Strassmann-Weg 2, 55128 Mainz (Germany); Hermanne, A. [VUB Cyclotron, University of Brussels, Laarbeeklaan 103, 1090 Brussels (Belgium); Mason, R.P. [Department of Radiology, Advanced Radiological Sciences, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas (United States); Thorpe, P.E. [Department of Pharmacology and Simmons and Hamon Cancer Centers, University of Texas Southwestern Medical Center at Dallas, Dallas, TX (United States); Roesch, F. [Institute of Nuclear Chemistry, Johannes Gutenberg University of Mainz, Fritz-Strassmann-Weg 2, 55128 Mainz (Germany)]. E-mail: frank.roesch@uni-mainz.de

    2006-12-20

    Radioarsenic labelled radiopharmaceuticals could be a valuable asset to positron emission tomography. In particular, the long half-lives of {sup 72}As (T{sub 1/2}=26h) and {sup 74}As (T{sub 1/2}=17.8d) allow to investigate slow physiological or metabolical processes, like the enrichment and distribution of monoclonal antibodies (mab) in tumour tissue. In this work, a new method for the labelling of proteins with various radioactive arsenic isotopes was developed. For this purpose, two proteins, namely a chimeric IgG{sub 3} monoclonal antibody, ch3G4, directed against anionic phospholipids, and Rituxan (Rituximab), were labelled as a proof of principle with no-carrier-added radioarsenic isotopes ({sup 74}As and {sup 77}As). The developed labelling chemistry gives high yields (>99.9%), is reliable and could easily be transferred to automated labelling systems in a clinical environment. At least for the mab used in this work, this route of radioarsenic labelling does not affect the immunoreactivity of the product. The arsenic label stays stable for up to 72h at the molecular mass of the monoclonal antibody, which is in particular relevant to follow the pharmacology and pharmacokinetics of the labelled mab for several days.

  15. Nurse educators' critical thinking: A mixed methods exploration.

    Science.gov (United States)

    Raymond, Christy; Profetto-McGrath, Joanne; Myrick, Florence; Strean, William B

    2018-07-01

    Nurse educator's critical thinking remains unexamined as a key factor in the development of students' critical thinking. The objective of this study is to understand how nurse educators reveal their critical thinking in the clinical setting while supervising students. This study uses a single-phase triangulation mixed methods design with multiple data gathering techniques. Participants for this study are clinical nurse educators from a large Western Canadian baccalaureate nursing program who teach 2nd or 3rd year students in medical-surgical settings. Participants for this study completed a demographic survey, the California Critical Thinking Skills Test (CCTST), the California Critical Thinking Disposition Inventory (CCTDI), participant observation in a clinical practice setting, and semi-structured interviews. The results from the California Critical Thinking assessments (CCTST and CCTDI) show that participants are positively inclined and have a moderate to strong ability to think critically, similar to other studies. Participants find it difficult to describe how they reveal their critical thinking in the clinical setting, yet all participants use role modeling and questioning to share their critical thinking with students. When the quantitative and qualitative results are compared, it is apparent that the confidence in reasoning subscale of the California Critical Thinking Skills Test is higher in those educators who more frequently demonstrate and voice engagement in reflective activities. Dispositions associated with critical thinking, as measured by the California Critical Thinking Disposition Inventory, are more easily observed compared to critical thinking skills. This study is a beginning exploration of nurse educators' critical thinking-in-action. Our mixed methods approach uncovers a valuable approach to understanding the complexity of nurse educators' critical thinking. Further study is needed to uncover how nurse educators' can specifically enact

  16. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Moreno, Laura, E-mail: laura.delgado@eez.csic.es; Wu, Laosheng; Gan, Jay

    2015-08-15

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C{sub free}). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r{sup 2} > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems.

  17. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    International Nuclear Information System (INIS)

    Delgado-Moreno, Laura; Wu, Laosheng; Gan, Jay

    2015-01-01

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C free ). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r 2 > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems

  18. Possibilities and scope of the double isotope effect method in the elucidation of mechanisms of enzyme catalyzed reactions

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H L; Medina, R [Technische Univ. Muenchen, Freising (Germany, F.R.). Lehrstuhl fuer Allgemeine Chemie und Biochemie

    1991-01-01

    Kinetic isotope effects on enzyme catalyzed reactions are indicative for the first irreversible in a sequence of individual steps. Hints on the relative velocities of other steps can only be obtained from the partitioning factor R and its dependence on external reaction conditions. In general, the experimental data needed are obtained from isotope abundance measurements in a defined position of the substrate or product as a function of turnover. This method does not reveal events dealing with neighbour atoms or preceding the main isotope sensitive step. In the method presented here, the analytical measurement is extended to the second atom involved in a bond fission of formation (Double Isotope Effect Method). It is shown that the additional results obtained support the identification of the main isotopically sensitive step and its relative contribution to the overall reaction rate, the identification of other kinetically significant steps and the differentiation between stepwise and concerted reaction mechanisms. The method and its advantages are demonstrated on reactions comprising C-N-bond splitting (urease and arginase reaction), C-C-bound fission (reactions catalyzed by pyruvate-dehydrogenase, pyruvate-formiate-lyase and lactate-oxidase), C-O-bound formation (ribulose-bisphosphate-oxygenase reaction), and N-O-bond fission (nitrate- and nitrite-reductase reactions). (orig.).

  19. Assessment for ion beam analysis methods about hydrogen isotope in hydrogen storaged metal

    International Nuclear Information System (INIS)

    Ding Wei; Long Xinggui; Shi Liqun

    2006-01-01

    In this paper, experimental arrangements of measuring hydrogen isotope concentration and distribution in metal hydride with ion beam analysis methods were reported, and the advantage and disadvantage of different methods were analyzed too. Experiment results show that it can get abundant information and accurate value by these ways. It can get an accurate value since it's the Rutherford cross-section, and the Mylar film used in the experiment is thin enough for H, D and T distinguishing each other while using ERD analysis method with 6.0 MeV O ion beam to proceed this work, but the disadvantage of this method is that the sample preparing is more difficult, and the analysis depth is lower. It could get the distribution information of H, D and T and the analysis depth is about 3.0 μm while using ERD analysis method with 7.4 MeV 4 He ion beam, but the disadvantage is that the spectra of H, D and T overlap each other, which makes a big error in simulated calculation. If using PBS method with 3.0 MeV proton, the analysis depth is deeper, but it couldn't get the H distribution information. (authors)

  20. Comparison of isotope dilution and excretion methods for determining the half-life of ascorbic acid in the guinea pig

    International Nuclear Information System (INIS)

    Kipp, D.E.; Rivers, J.M.

    1984-01-01

    The half-life of ascorbic acid (AA) in guinea pigs was investigated by the isotope dilution and excretion methods. The dilution method measures [1-14C]AA disappearance from the plasma, whereas the excretion method measures the elimination of [1-14C]AA and the metabolites from the body. Two groups of animals underwent both isotope studies in reverse order. Animals were conditioned to the experimental procedures and fed 2.5 mg AA/100 g body weight orally to maintain a daily intake of the vitamin independent of food consumption. The two isotope procedures imposed similar stress on the animals, as determined by plasma cortisol levels and body weight changes. The AA half-life calculations of the rapidly exchangeable pool by the isotope dilution method yielded values of 1.23 and 0.34 hours for the two groups, respectively. The half-life of the slowly exchangeable pool for the two groups was 60.2 and 65.8 hours, respectively. The half-life of AA in the rapidly exchangeable pool, as measured by the excretion studies, was 4.57-8.75 hours. For the slowly exchangeable pool, it was 146-149 hours. The longer half-life of both pools obtained with the excretion method indicates that the isotope is disappearing from the plasma more rapidly than it is being excreted. This suggests that a portion of the [1-14C]AA leaving the plasma is removed to a body pool that is not sampled by the isotope excretion method

  1. Isotope Identification

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-18

    The objective of this training modules is to examine the process of using gamma spectroscopy for radionuclide identification; apply pattern recognition to gamma spectra; identify methods of verifying energy calibration; and discuss potential causes of isotope misidentification.

  2. Isotopic separation

    International Nuclear Information System (INIS)

    Castle, P.M.

    1979-01-01

    This invention relates to molecular and atomic isotope separation and is particularly applicable to the separation of 235 U from other uranium isotopes including 238 U. In the method described a desired isotope is separated mechanically from an atomic or molecular beam formed from an isotope mixture utilising the isotropic recoil momenta resulting from selective excitation of the desired isotope species by radiation, followed by ionization or dissociation by radiation or electron attachment. By forming a matrix of UF 6 molecules in HBr molecules so as to collapse the V 3 vibrational mode of the UF 6 molecule the 235 UF 6 molecules are selectively excited to promote reduction of UF 6 molecules containing 235 U and facilitate separation. (UK)

  3. Measurement of solubility of hydrogen isotopes in Li-Pb by adsorption and desorption method

    International Nuclear Information System (INIS)

    Edao, Yuki; Katayama, K.; Fukada, S.

    2014-01-01

    Measurement of tritium solubility in lithium lead eutectic alloy (Li-Pb) has been performed under the Japan-US collaboration work of 'TITAN'. The present paper reports that results of H and D solubility in Li-Pb which melted in an alumina tube determined by means of a constant volume method, and also reports an experimental apparatus for measurement of tritium solubility in Li-Pb in a tungsten crucible is improved and examined in the STAR facility of the Idaho National Laboratory. It was shown that H solubility in Li-Pb was easily influenced by impurities, interaction with surrounding materials and evaporated Li-Pb. The influences were suggested to be caused by large scattering among the previously reported data on solubility of hydrogen isotopes in Li-Pb. (author)

  4. The momentum-loss achromat - a new method for the isotopical separation of relativistic heavy ions

    International Nuclear Information System (INIS)

    Schmidt, K.H.; Geissel, H.; Muenzenberg, G.; Dufour, J.P.; Hanelt, E.

    1987-03-01

    The application of the slowing-down process of relativistic heavy ions in a layer of matter in ion-optical devices is theoretically investigated. The modifications of the phase space of the ion beam due to the dissipative forces and the straggling phenomena are discussed. Methods are developed to study the properties of the momentum-loss achromat, an isotope separator consisting of an achromatic magnetic system with an energy degrader located in the intermediate dispersive focal plane. This device separates projectile fragments with respect to A and Z up to uranium over a wide energy range with an efficiency in the order of 50% and with separation times of several hundred nanoseconds. (orig.)

  5. Methods of clinical chemistry and isotopic technique for investigation of the nitrogen metabolism in man using 15N

    International Nuclear Information System (INIS)

    Faust, H.; Bornhak, H.; Hirschberg, K.; Jung, K.; Junghans, P.; Krumbiegel, P.; Reinhardt, R.

    1981-03-01

    The present manual is a catalogue of methods representing theoretical and practical aspects of application of the stable isotope 15 N in medicine as well as a reference book for users of 15 N techniques in life sciences. Special emphasis is given to the planning of 15 N tracer experiments and their interpretation, sources of error and standard values of nitrogen compounds, information on sampling of medical materials, methods of separation and determination of proteins and non-protein nitrogen compounds in serum and urine, and details of the isotopic analysis of nitrogen by emission and mass spectrometry. (author)

  6. Isotopic separation

    International Nuclear Information System (INIS)

    Chen, C.L.

    1982-01-01

    A method is described for separating isotopes in which photo-excitation of selected isotope species is used together with the reaction of the excited species with postive ions of predetermined ionization energy, other excited species, or free electrons to produce ions or ion fragments of the selected species. Ions and electrons are produced by an electrical discharge, and separation is achieved through radial ambipolar diffusion, electrostatic techniques, or magnetohydrodynamic methods

  7. A simple cleanup method for the isolation of nitrate from natural water samples for O isotopes analysis

    International Nuclear Information System (INIS)

    Haberhauer, G.; Blochberger, K.

    1999-09-01

    The analysis of O-isotopic composition of nitrate has many potential applications in studies of environmental processes. O-isotope nitrate analysis require sample free of other oxygen-containing compounds. More than 100 % of non-NO 3 - oxygen relative to NO 3 - oxygen can still be found in forest soil water samples after cleanup if improper cleanup strategies, e.g., adsorption onto activated carbon, are used. Such non-NO 3 - oxygen compounds will bias O-isotropic data. Therefore, an efficient cleanup method was developed to isolate nitrate from natural water samples. In a multistep cleanup procedure using adsorption onto water-insoluble poly(vinylpyrrolidone), removal of almost all other oxygen-containing compounds, such as fulvic acids, and isolation of nitrate was achieved. The method supplied samples free of non-NO 3 - oxygen which can be directly combusted to CO 2 for subsequent O-isotope analysis. (author)

  8. Effects of euthanasia method on stable-carbon and stable-nitrogen isotope analysis for an ectothermic vertebrate.

    Science.gov (United States)

    Atwood, Meredith A

    2013-04-30

    Stable isotope analysis is a critical tool for understanding ecological food webs; however, results can be sensitive to sample preparation methods. To limit the possibility of sample contamination, freezing is commonly used to euthanize invertebrates and preserve non-lethal samples from vertebrates. For destructive sampling of vertebrates, more humane euthanasia methods are preferred to freezing and it is essential to evaluate how these euthanasia methods affect stable isotope results. Stable isotope ratios and elemental composition of carbon and nitrogen were used to evaluate whether the euthanasia method compromised the integrity of the sample for analysis. Specifically, the stable isotope and C:N ratios were compared for larval wood frogs (Rana sylvatica  =  Lithobates sylvaticus), an ectothermic vertebrate, that had been euthanized by freezing with four different humane euthanasia methods: CO2, benzocaine, MS-222 (tricaine methanesulfonate), and 70% ethanol. The euthanasia method was not related to the δ(13)C or δ(15)N values and the comparisons revealed no differences between freezing and any of the other treatments. However, there were slight (non-significant) differences in the isotope ratios of benzocaine and CO2 when each was compared with freezing. The elemental composition was altered by the euthanasia method employed. The percentage nitrogen was higher in CO2 treatments than in freezing, and similar (non-significant) trends were seen for ethanol treatments relative to freezing. The resulting C:N ratios were higher for benzocaine treatments than for both CO2 and ethanol. Similar (non-significant) trends suggested that the C:N ratios were also higher for animals euthanized by freezing than for both CO2 and ethanol euthanasia methods. The euthanasia method had a larger effect on elemental composition than stable isotope ratios. The percentage nitrogen and the subsequent C:N ratios were most affected by the CO2 and ethanol euthanasia methods, whereas

  9. Study of the extraction of the traces of Cadmium through the method of subestequiometric isotope dilution

    International Nuclear Information System (INIS)

    Garate V, Z.

    1990-01-01

    In this work, it has been used the method of subestequiometric isotope dilution for the determination of traces of cadmium and it has been compared with other conventional's methods for study its performance. The conditions of the experiment had been studied carefully in order to optimize the parameters such as pH, (8,0 - 10,1) it used the buffer NH 3 :NH 4 Cl, the time of agitation (>120 s) and the concentration of the organic reactive (dithizone). Besides, it obtains the respective curve of calibration. In this study, we can watch a line relation in all the range studied (5-40 μg of Cd). This method applied to the analysis of Cadmium in a certified sample of H-8 of the IAEA, it gives us the next value: 195 ± 5,4 ppm (LOD= 1,5 ppm, LOQ= 4,8 ppm), it is enough satisfactory in comparison with the certified middle value of 188,9±19 ppm. It demonstrates the utility of the method in the Cadmium traces analysis if it disposes of the radioisotope of this element and the appropriate detection equipment. (DEM). 34 refs., 15 tabs., 7 figs

  10. A simple and reliable method reducing sulfate to sulfide for multiple sulfur isotope analysis.

    Science.gov (United States)

    Geng, Lei; Savarino, Joel; Savarino, Clara A; Caillon, Nicolas; Cartigny, Pierre; Hattori, Shohei; Ishino, Sakiko; Yoshida, Naohiro

    2018-02-28

    Precise analysis of four sulfur isotopes of sulfate in geological and environmental samples provides the means to extract unique information in wide geological contexts. Reduction of sulfate to sulfide is the first step to access such information. The conventional reduction method suffers from a cumbersome distillation system, long reaction time and large volume of the reducing solution. We present a new and simple method enabling the process of multiple samples at one time with a much reduced volume of reducing solution. One mL of reducing solution made of HI and NaH 2 PO 2 was added to a septum glass tube with dry sulfate. The tube was heated at 124°C and the produced H 2 S was purged with inert gas (He or N 2 ) through gas-washing tubes and then collected by NaOH solution. The collected H 2 S was converted into Ag 2 S by adding AgNO 3 solution and the co-precipitated Ag 2 O was removed by adding a few drops of concentrated HNO 3 . Within 2-3 h, a 100% yield was observed for samples with 0.2-2.5 μmol Na 2 SO 4 . The reduction rate was much slower for BaSO 4 and a complete reduction was not observed. International sulfur reference materials, NBS-127, SO-5 and SO-6, were processed with this method, and the measured against accepted δ 34 S values yielded a linear regression line which had a slope of 0.99 ± 0.01 and a R 2 value of 0.998. The new methodology is easy to handle and allows us to process multiple samples at a time. It has also demonstrated good reproducibility in terms of H 2 S yield and for further isotope analysis. It is thus a good alternative to the conventional manual method, especially when processing samples with limited amount of sulfate available. © 2017 The Authors. Rapid Communications in Mass Spectrometry Pubished by John Wiley & Sons Ltd.

  11. Isotope angiocardiography

    International Nuclear Information System (INIS)

    Stepinska, J.; Ruzyllo, W.; Konieczny, W.

    1979-01-01

    Method of technetium isotope 99 m pass through the heart recording with the aid of radioisotope scanner connected with seriograph and computer is being presented. Preliminary tests were carried out in 26 patients with coronary disease without or with previous myocardial infarction, cardiomyopathy, ventricular septal defect and in patients with artificial mitral and aortic valves. The obtained scans were evaluated qualitatively and compared with performed later contrast X-rays of the heart. Size of the right ventricle, volume and rate of left atrial evacuation, size and contractability of left ventricle were evaluated. Similarity of direct and isotope angiocardiographs, non-invasional character and repeatability of isotope angiocardiography advocate its usefulness. (author)

  12. LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

    Science.gov (United States)

    Zuwei, Wang; Boyd, Jason; Berens, Kurt L.; Putcha, Lakshmi

    2004-01-01

    Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

  13. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    Science.gov (United States)

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods

    International Nuclear Information System (INIS)

    Balachandran, S.; Toguri, A.G.; Petrusick, T.W.; Abbott, L.C.

    1981-01-01

    Good correlation of glomerular filtration rate (GFR) measured isotopically from plasma disappearance of Tc-99m-DTPA (Sn) was shown with inulin clearance, creatinine clearance, and graded radionuclide imaging. The isotopic GFR is a simple, urineless technique not requiring continuous infusion that enables one to perform simultaneous renal imaging with one radiotracer

  15. High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wall, Andrew J. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Capo, Rosemary C. [Univ. of Pittsburgh, PA (United States); Stewart, Brian W. [Univ. of Pittsburgh, PA (United States); Phan, Thai T. [Univ. of Pittsburgh, PA (United States); Jain, Jinesh C. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Hakala, Alexandra [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Guthrie, George D. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States)

    2016-09-22

    This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

  16. High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, Jacqueline Alexandra [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2016-11-22

    This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

  17. Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Schierbeek, Henk; te Braake, Frans; Godin, Jean-Philippe; Fay, Laurent-Bernard; van Goudoever, Johannes B.

    2007-01-01

    A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1-(13)C]-glycine as a tracer. After transformation of GSH into GSSG, its

  18. Testing isotopic labeling with [¹³C₆]glucose as a method of advanced glycation sites identification.

    Science.gov (United States)

    Kielmas, Martyna; Kijewska, Monika; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2012-12-01

    The Maillard reaction occurring between reducing sugars and reactive amino groups of biomolecules leads to the formation of a heterogeneous mixture of compounds: early, intermediate, and advanced glycation end products (AGEs). These compounds could be markers of certain diseases and of the premature aging process. Detection of Amadori products can be performed by various methods, including MS/MS techniques and affinity chromatography on immobilized boronic acid. However, the diversity of the structures of AGEs makes detection of these compounds more difficult. The aim of this study was to test a new method of AGE identification based on isotope (13)C labeling. The model protein (hen egg lysozyme) was modified with an equimolar mixture of [(12)C(6)]glucose and [(13)C(6)]glucose and then subjected to reduction of the disulfide bridges followed by tryptic hydrolysis. The digest obtained was analyzed by LC-MS. The glycation products were identified on the basis of characteristic isotopic patterns resulting from the use of isotopically labeled glucose. This method allowed identification of 38 early Maillard reaction products and five different structures of the end glycation products. This isotopic labeling technique combined with LC-MS is a sensitive method for identification of advanced glycation end products even if their chemical structure is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Using Isotope Methods to Assess Groundwater Recharge in Some Hydraulic Catchments in a Semiarid Region in Central Tunisia

    Energy Technology Data Exchange (ETDEWEB)

    Zouari, K.; Trabelsi, R.; Kacem, A. [Laboratory of Radio-Analysis and Environment, ENIS, Sfax (Tunisia)

    2013-07-15

    Water resource issues constitute a major concern in arid and semiarid areas in Tunisia. To meet rising demand for different human activities considerable importance is being given to improving the natural groundwater recharge by the installation of hydraulic catchments. In central Tunisia, numerous retention sites and dams have been built since 1990, for example, the el Ogla dam in the Nadhour-Saouaf basin. In order to determine the implication of these hill reservoirs on the hydrodynamic functioning and water quality of the aquifer system, hydrochemical (major elements) and isotopic methods have been employed. The interpretation of these results showed that the shallow aquifer is recharged mainly by surface water and water dam infiltration from the el Ogla and Sahel catchments. A tentative isotopic mass balance based on stable isotope contents leads to the quantification of the artificial recharge rate, which ranges between 42% and 86% of precipitation in the humid period. (author)

  20. Online induction heating for determination of isotope composition of woody stem water with laser spectrometry: A methods assessment

    Science.gov (United States)

    Lazarus, Brynne E.; Germino, Matthew; Vander Veen, Jessica L.

    2016-01-01

    Application of stable isotopes of water to studies of plant–soil interactions often requires a substantial preparatory step of extracting water from samples without fractionating isotopes. Online heating is an emerging approach for this need, but is relatively untested and major questions of how to best deliver standards and assess interference by organics have not been evaluated. We examined these issues in our application of measuring woody stem xylem of sagebrush using a Picarro laser spectrometer with online induction heating. We determined (1) effects of cryogenic compared to induction-heating extraction, (2) effects of delivery of standards on filter media compared to on woody stem sections, and (3) spectral interference from organic compounds for these approaches (and developed a technique to do so). Our results suggest that matching sample and standard media improves accuracy, but that isotopic values differ with the extraction method in ways that are not due to spectral interference from organics.

  1. Measurement of liquid mixing characteristics in large-sized ion exchange column for isotope separation by stepwise response method

    International Nuclear Information System (INIS)

    Fujine, Sachio; Saito, Keiichiro; Iwamoto, Kazumi; Itoi, Toshiaki.

    1981-07-01

    Liquid mixing in a large-sized ion exchange column for isotope separation was measured by the step-wise response method, using NaCl solution as tracer. A 50 cm diameter column was packed with an ion exchange resin of 200 μm in mean diameter. Experiments were carried out for several types of distributor and collector, which were attached to each end of the column. The smallest mixing was observed for the perforated plate type of the collector, coupled with a minimum stagnant volume above the ion exchange resin bed. The 50 cm diameter column exhibited the better characteristics of liquid mixing than the 2 cm diameter column for which the good performance of lithium isotope separation had already been confirmed. These results indicate that a large increment of throughput is attainable by the scale-up of column diameter with the same performance of isotope separation as for the 2 cm diameter column. (author)

  2. A comparison of the toluene distillation and vacuum/heat methods for extracting soil water for stable isotopic analysis

    Science.gov (United States)

    Ingraham, Neil L.; Shadel, Craig

    1992-12-01

    Hanford Loam, from Richland, Washington, was used as a test soil to determine the precision, accuracy and nature of two methods to extract soil water for stable isotopic analysis: azeotropic distillation using toluene, and simple heating under vacuum. The soil was oven dried, rehydrated with water of known stable isotopic compositions, and the introduced water was then extracted. Compared with the introduced water, initial aliquots of evolved water taken during a toluene extraction were as much as 30 ‰ more depleted in D and 2.7 ‰ more depleted in 18O, whereas final aliquots were as much as 40 ‰ more enriched in D and 14.3 ‰ more enriched in 18O. Initial aliquots collected during the vacuum/heat extraction were as much as 64 ‰ more depleted in D and 8.4 ‰ more depleted in 18O than was the introduced water, whereas the final aliquots were as much as 139 ‰ more enriched in D, and 20.8 ‰ more enriched in 18O. Neither method appears quantitative; however, the difference in stable isotopic composition between the first and last aliquots of water extracted by the toluene method is less than that from the vacuum/heat method. This is attributed to the smaller fractionation factors involved with the higher average temperatures of distillation of the toluene. The average stable isotopic compositions of the extracted water varied from that of the introduced water by up to 1.4 ‰ in δD and 4.2 ‰ in δ18O with the toluene method, and by 11.0 ‰ in δD and 1.8 ‰ in δ18O for the vacuum/heat method. The lack of accuracy of the extraction methods is thought to be due to isotopic fractionation associated with water being weakly bound (not released below 110°C) in the soil. The isotopic effect of this heat-labile water is larger at low water contents (3.6 and 5.2% water by weight) as the water bound in the soil is a commensurately larger fraction of the total. With larger soilwater contents the small volume of water bound with an associated fractionation is

  3. Isotope enrichment

    International Nuclear Information System (INIS)

    Lydtin, H-J.; Wilden, R.J.; Severin, P.J.W.

    1978-01-01

    The isotope enrichment method described is based on the recognition that, owing to mass diffusion and thermal diffusion in the conversion of substances at a heated substrate while depositing an element or compound onto the substrate, enrichment of the element, or a compound of the element, with a lighter isotope will occur. The cycle is repeated for as many times as is necessary to obtain the degree of enrichment required

  4. Study on Method of Asphalt Density Measurement Using Low Level Radioactive Isotope

    International Nuclear Information System (INIS)

    Chung, Jin-young; Kim, Jung-hoon; Whang, Joo-ho

    2008-01-01

    The fundamental cause of damage to road pavement is insufficient management of asphalt density during construction. Currently, asphalt density in Korea is measured in a laboratory by extracting a core sample after construction. This method delays the overall time of measurement and therefore it is difficult to achieve real-time density management. Using a radioactive isotope for measuring asphalt density during construction reduces measuring time thus enabling realtime measurement. Also, it is provided reliable density measurement to achieve effective density management at work sites. However, existing radiological equipment has not been widely used because of management restrictions and regulations due to the high radiation dose. In this study, we employed a non-destructive method for density measurement. Density is measured by using a portable gamma-ray backscatter device having a radioactivity emission of 100 μCi or less (notice No. 2002-23, Ministry of Science and Technology, standards on radiation protection, etc.), a sealed radioactive source subject to declaration

  5. Introduction and optimization of methods for isotopic determination of thorium and uranium via α-spectroscopy and their applications in analysis of water from Morro do Ferro, Brazil

    International Nuclear Information System (INIS)

    Vale, M.G.R.

    1982-01-01

    Methods for isotopic determination of thorium and uranium via α-spectroscopy, using a surface barrier detector, are described. The methods were applied in surface waters, borehole water, sediments and minerals from Morro do Ferro (MG), Brazil. Results and analysis by different techniques are compared and some discussions concerning to Th-concentration levels and anomalous isotopic and nuclidic ratios are presented. (Author) [pt

  6. Standard test method for determination of uranium or plutonium isotopic composition or concentration by the total evaporation method using a thermal ionization mass spectrometer

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method describes the determination of the isotopic composition and/or the concentration of uranium and plutonium as nitrate solutions by the thermal ionization mass spectrometric (TIMS) total evaporation method. Purified uranium or plutonium nitrate solutions are loaded onto a degassed metal filament and placed in the mass spectrometer. Under computer control, ion currents are generated by heating of the filament(s). The ion beams are continually measured until the sample is exhausted. The measured ion currents are integrated over the course of the run, and normalized to a reference isotope ion current to yield isotopic ratios. 1.2 In principle, the total evaporation method should yield isotopic ratios that do not require mass bias correction. In practice, some samples may require this bias correction. When compared to the conventional TIMS method, the total evaporation method is approximately two times faster, improves precision from two to four fold, and utilizes smaller sample sizes. 1.3 The tot...

  7. Method for estimating the inventory of an isotope separation cascade by the use of minor isotope transient concentration data

    International Nuclear Information System (INIS)

    Blumkin, S.; Von Halle, E.

    1978-01-01

    An indirect method for estimating the inventory of a uranium enrichment cascade which presumably can be performed by the International Atomic Energy Agency within the Non-Proliferation Treaty limitations on its safeguards activities was devised and tested at the Oak Ridge Gaseous Diffusion Plant (ORGDP). This method involves the feeding of a cascade with uranium that is significantly richer in one component than the normal cascade feed for a short period of time, and the measurement of the subsequent transient concentrations of this component in the cascade withdrawal streams. The inventory estimate is then obtained from a comparison of the observed data with parallel data calculated for an appropriate but non-identical cascade model. The validity of the method is demonstrated numerically by parallel calculations made for two nearly ideal hypothetical cascade models. A test of this method conducted in the ORGDP cascade, utilizing U-236 as the spike component, yielded an estimate of the cascade inventory greater by 3.0% than that determined by the usual measurement method. The proposed method has been devised for use at enrichment plants that are subject to safeguarding by the IAEA and for which the proprietors will permit the inventories to be known. The method does not require knowledge or determination of any technology information that may be considered to be sensitive. For it to be applied, a plant proprietor must be willing to spike his cascade with a non-normal feed and do or permit the extensive sampling of its feed and withdrawal streams that is entailed. The numerical demonstration of the validity of the method rests on a single comparison of two nearly hypothetical cascades

  8. Comparison between isotope dilution and activation analysis as a method for determining the macro content of mercury

    International Nuclear Information System (INIS)

    Soedyartomo; Sunoko, S.R.

    1975-01-01

    It is true that the mercury content in the environment should be measured accurately because of its toxicity even at levels of microgram order. The assessment of hazards due to environmental contamination with mercury is based on the results of the metal analysis in a number of different samples. Consequently, the study of the character of analytical methods used, i.e. their accuracy, precision, sensitivity, etc. is essential. A brief description on the microanalysis methods of mercury as given. The discussion of the results obtained from analysing some sludge and water by means of isotope dilution and destructive thermal neutron activation analysis is also presented. It is found that both methods are suitable for routine work. It can be concluded that the isotope dilution method has some advantages. It is more simple, more sensitive, more rapid, and has lower radiation hazard. (author)

  9. Removal method of fluorescent dyes as pretreatment for measurement of major ion concentrations and hydrogen and oxygen isotopic ratios

    International Nuclear Information System (INIS)

    Nakata, Kotaro; Hasegawa, Takuma; Kashiwaya, Koki; Kodama, Hiroki; Miyajima, Tohru

    2011-01-01

    The major ion concentration and isotope ratio of hydrogen and oxygen can provide important information for migration of groundwater. Sometimes, quantitative estimation of these chemical and isotopic characteristics of solution is necessary for groundwater containing fluorescent dyes, which are used in drilling borehole and tracer experiments. However, sometimes correct estimation is disturbed by dyes and they become a cause of troubles for measurement equipments. Thus development of method to remove dyes is required so that the characteristics of groundwater can be estimated without the negative effect of dyes on measurement or equipments. In this study, removal of four representative dyes (Uranin, Eosin, Naphthalenesulfonic acid sodium(NAP) and Amino G acid potassium salt (AG)) was investigated. Uranin and Eosin were found to be removed by non-ionic synthetic resin: HP2MG. 99.99% of the dyes were removed from initial solutions containing dyes with 10 mg/L after contact with resin, while the contact had little effect on ion concentrations and oxygen and hydrogen isotope ratios. Thus the chemical and isotopic characteristics of groundwater samples containing Uranin and Eosin can be obtained by using the HP2MG resin. On the other hand, the NAP and AG were found to be difficult to remove by the HP2MG resin but they were able to be removed by anion exchange resin (Dowex 1x8). Though contact of solution with Dowex 1x8 did not affect cation concentrations and hydrogen and oxygen isotope ratios, anion concentrations were changed by the contact. Therefore the Dowex 1x8 is only applicable to estimation of the cation concentrations and isotope ratio of hydrogen and oxygen. When both anion and cation concentrations from the samples were necessary, Uranin or Eosin were recommended as a tracer in drilling or tracer experiments. (author)

  10. The sweep-line state space exploration method

    DEFF Research Database (Denmark)

    Jensen, Kurt; Kristensen, Lars M.; Mailund, Thomas

    2012-01-01

    . The contribution of this paper is twofold. First, we provide a coherent presentation of the sweep-line theory and the many variants of the method that have been developed over the past 10 years since the basic idea of the method was conceived. Second, we survey a selection of case studies where the sweep...

  11. Field radiometric methods of prospecting and exploration for uranium ores

    International Nuclear Information System (INIS)

    Gorbushina, L.V.; Savenko, E.I.; Serdyukova, A.S.

    1978-01-01

    The textbook includes two main chapters which describe gamma- and emanation field radiometric methods. The textbook is intended for geology and geophysics students having training practice in field radiometric methods and is additional to the course of lectures. The textbook can be used in the''Radiometry'' course which is studied in appropriate geological and technical colleges

  12. Development of a Method to Isolate Glutamic Acid from Foodstuffs for a Precise Determination of Their Stable Carbon Isotope Ratio.

    Science.gov (United States)

    Kobayashi, Kazuhiro; Tanaka, Masaharu; Yatsukawa, Yoichi; Tanabe, Soichi; Tanaka, Mitsuru; Ohkouchi, Naohiko

    2018-01-01

    Recent growing health awareness is leading to increasingly conscious decisions by consumers regarding the production and traceability of food. Stable isotopic compositions provide useful information for tracing the origin of foodstuffs and processes of food production. Plants exhibit different ratios of stable carbon isotopes (δ 13 C) because they utilized different photosynthetic (carbon fixation) pathways and grow in various environments. The origins of glutamic acid in foodstuffs can be differentiated on the basis of these photosynthetic characteristics. Here, we have developed a method to isolate glutamic acid in foodstuffs for determining the δ 13 C value by elemental analyzer-isotope-ratio mass spectrometry (EA/IRMS) without unintended isotopic fractionation. Briefly, following acid-hydrolysis, samples were defatted and passed through activated carbon and a cation-exchange column. Then, glutamic acid was isolated using preparative HPLC. This method is applicable to measuring, with a low standard deviation, the δ 13 C values of glutamic acid from foodstuffs derived from C3 and C4 plants and marine algae.

  13. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyes. Review

    Energy Technology Data Exchange (ETDEWEB)

    Skrzypek, G. [West Australian Biogeochemistry Centre, John de Laeter Centre of Mass Spectrometry, School of Plant Biology, University of Western Australia, Crawley (Australia); Sadler, R. [School of Agricultural and Resource Economics, University of Western Australia, Crawley (Australia); Paul, D. [Department of Civil Engineering (Geosciences), Indian Institute of Technology Kanpur, Kanpur (India); Forizs, I. [Institute for Geochemical Research, Hungarian Academy of Sciences, Budapest (Hungary)

    2013-07-15

    Stable isotope ratio mass spectrometers are highly precise, but not accurate instruments. Therefore, results have to be normalized to one of the isotope scales (e.g., VSMOW, VPDB) based on well calibrated reference materials. The selection of reference materials, numbers of replicates, {delta}-values of these reference materials and normalization technique have been identified as crucial in determining the uncertainty associated with the final results. The most common normalization techniques and reference materials have been tested using both Monte Carlo simulations and laboratory experiments to investigate aspects of error propagation during the normalization of isotope data. The range of observed differences justifies the need to employ the same sets of standards worldwide for each element and each stable isotope analytical technique. (author)

  14. Discovery of the iron isotopes

    International Nuclear Information System (INIS)

    Schuh, A.; Fritsch, A.; Heim, M.; Shore, A.; Thoennessen, M.

    2010-01-01

    Twenty-eight iron isotopes have been observed so far and the discovery of these isotopes is discussed here. For each isotope a brief summary of the first refereed publication, including the production and identification method, is presented.

  15. Discovery of the silver isotopes

    International Nuclear Information System (INIS)

    Schuh, A.; Fritsch, A.; Ginepro, J.Q.; Heim, M.; Shore, A.; Thoennessen, M.

    2010-01-01

    Thirty-eight silver isotopes have been observed so far and the discovery of these isotopes is discussed here. For each isotope a brief summary of the first refereed publication, including the production and identification method, is presented.

  16. Discovery of the cadmium isotopes

    International Nuclear Information System (INIS)

    Amos, S.; Thoennessen, M.

    2010-01-01

    Thirty-seven cadmium isotopes have been observed so far and the discovery of these isotopes is discussed here. For each isotope a brief summary of the first refereed publication, including the production and identification method, is presented.

  17. Exploration

    International Nuclear Information System (INIS)

    Lohrenz, J.

    1992-01-01

    Oil and gas exploration is a unique kind of business. Businesses providing a vast and ever-changing panoply of products to markets are a focus of several disciplines' energetic study and analysis. The product inventory problem is robust, pertinent, and meaningful, and it merits the voluminous and protracted attention received from keen business practitioners. Prototypical business practitioners, be they trained by years of business hurly-burly, or sophisticated MBAs with arrays of mathematical algorithms and computers, are not normally prepared, however, to recognize the unique nature of exploration's inventories. Put together such a business practitioner with an explorationist and misunderstandings, hidden and open, are inevitable and predictably rife. The first purpose of this paper is to articulate the inherited inventory handling paradigms of business practitioners in relation to exploration's inventories. To do so, standard pedagogy in business administration is used and a case study of an exploration venture is presented. A second purpose is to show the burdens that the misunderstandings create. The result is not just business plans that go awry, but public policies that have effects opposite from those intended

  18. The separation nozzle method for enrichment of the light uranium isotope

    International Nuclear Information System (INIS)

    Becker, E.W.

    1982-05-01

    The history of the development of the separation nozzle method for enrichment of the light uranium isotope is described as a contribution to a memorandum published by Deutsche Forschungsgemeinschaft. The work was triggered off by an effect which had been observed in fundamental studies on gas kinetics. Development up to the technical maturity covered a period of more than 25 years. The implementation of the project at the Karlsruhe Nuclear Research Center provided an adequate financial and technical framework, the employment of senior staff without limitations in time being of major importance for the continuity of work. The links established between the Institute and the University and the resulting opportunity of having doctoral theses written, on the other hand, gave rise to a permanent flow of young, highly qualified scientists and engineers. Thus the Institut's requirements for junior staff could be satisfied in an optimum way. Although the Center offered a variety of possibilities of internal technical cooperation, important developments were performed jointly with industrial firms experienced in related fields. By this, not only a steady flow of know-how had been accumulated but also the large-scale applicability was ensured at a later date of results jointly obtained. (orig.) [de

  19. Comparison of force fields and calculation methods for vibration intervals of isotopic H+3 molecules

    International Nuclear Information System (INIS)

    Carney, G.D.; Adler-Golden, S.M.; Lesseski, D.C.

    1986-01-01

    This paper reports (a) improved values for low-lying vibration intervals of H + 3 , H 2 D + , D 2 H + , and D + 3 calculated using the variational method and Simons--Parr--Finlan representations of the Carney--Porter and Dykstra--Swope ab initio H + 3 potential energy surfaces, (b) quartic normal coordinate force fields for isotopic H + 3 molecules, (c) comparisons of variational and second-order perturbation theory, and (d) convergence properties of the Lai--Hagstrom internal coordinate vibrational Hamiltonian. Standard deviations between experimental and ab initio fundamental vibration intervals of H + 3 , H 2 D + , D 2 H + , and D + 3 for these potential surfaces are 6.9 (Carney--Porter) and 1.2 cm -1 (Dykstra--Swope). The standard deviations between perturbation theory and exact variational fundamentals are 5 and 10 cm -1 for the respective surfaces. The internal coordinate Hamiltonian is found to be less efficient than the previously employed ''t'' coordinate Hamiltonian for these molecules, except in the case of H 2 D +

  20. Evaluation of phosphatic fertilizers of different solubility for common bean using isotopic methods

    International Nuclear Information System (INIS)

    Garcia Altunaga, Aurelio; Hernandez Barrueta, German; Nuviola Montoya, Antonio; Mendez Perez, Nancy; Herrero Echevarria, Grisel; Drevon, Jean Jacques

    2005-01-01

    Glass house experiments were carried out in the Experimental Station La Renee located in Habana province in the year 2003. The objective of this study was to evaluate the effectiveness of phosphorus (P) sources varying in solubility for common bean (Phaseolus vulgaris L.) nutrition using the isotopic dilution method with 32 P , growing under two soils: Acrisol and Rhodic Ferralsol. The P sources, evaluated in both soils were phosphate rock (PR) Trinidad de Guedes and PR partially solubilized at 50% with H 2 SO 4 , namely FPA 50, whereas single super phosphate (SS) and triple super phosphate (TSP) were used in the Acrisol and Rhodic Ferralsol Soils, respectively. The common bean genotypes were BAT 477, DOR 364, DOR 390 and Censa, and BAT 58, BAT 477, DOR 364 and CC-25-9(N) in the Acrisol and Rhodic Felrrasol soils, respectively. Dry matter production, P extraction, and the fraction and quantity of P in plants obtained from different P sources were evaluated, and P use efficiency of each P fertilizer were calculated. Single and tripe super phosphate and FPA 50 were effective P fertilizers in both soils whereas RF was not. (author) [es

  1. Isotope method to study the replenishment the lakes and downstream groundwater in Badain Jaran desert

    International Nuclear Information System (INIS)

    Chen Jiansheng; Fan Zhechao; Gu Weizu; Zhao Xia; Wang Jiyang

    2003-01-01

    In the paper, the sources of spring water and well water of Qilian Mountain's north side, Longshou Mountain, Badain Jaran Desert, Gurinai, Guaizi Lake, and Ejina Basin are studied by the methods of environmental isotopes and water chemistry. The groundwater of downstream areas (such as Badain Jaran Desert) is found that it is recharged by the precipitation of Qilian Mountain, and the average recharge elevation is 3300 m. Lots of naked limestones layers exist at the mountaintop of Qilian Mountain. The snow water of Qilian Mountain melts and directly infiltrates into deep layer passing through karst stratum or Big Fault in Front of the Mountain, and directly recharges into Badain Jaran Desert and its downstream areas passing through Longshou Mountain. The calcareous cementation and travertine, found in the lakes of the desert, approve that the groundwater passed the limestone layer. Confined water recharges shallow aquifer by means of leakage. The groundwater recharge volume is six hundreds millions cubic meters per year by calculating the evaporation amount, and the age of confined groundwater is 20-30 years. (authors)

  2. The method of life extension for the High Flux Isotope Reactor vessel

    International Nuclear Information System (INIS)

    Chang, Shib-Jung.

    1995-01-01

    The state of the vessel steel embrittlement as a result of neutron irradiation can be measured by its increase in the nil ductility temperature (NDT). This temperature is sometimes referred to as the brittle-ductile transition temperature (DBT) for fracture. The life extension of the High Flux Isotope Reactor (HFIR) vessel is calculated by using the method of fracture mechanics. A hydrostatic pressure test (hydrotest) is performed in order to determine a safe vessel static pressure. It is then followed by using fracture mechanics to project the reactor life from the safe hydrostatic pressure. The life extension calculation provides the following information on the remaining life of the reactor as a function of the nil ductility temperature increase: the probability of vessel fracture due to hydrotest vs vessel life at several hydrotest pressures; the hydrotest time interval vs the uncertainty of the nil ductility temperature increase rate; and the hydrotest pressure vs the uncertainty of the nil ductility temperature increase rate. It is understood that the use of a complete range of uncertainties of the nil ductility temperature increase is equivalent to the entire range of radiation damage that can be experienced by the vessel steel. From the numerical values for the probabilities of the vessel fracture as a result of hydrotest, it is estimated that the reactor vessel life can be extended up to 50 EFPY (100 MW) with the minimum vessel operating temperature equal to 85 degree F

  3. Industrial ecology: Quantitative methods for exploring a lower carbon future

    Science.gov (United States)

    Thomas, Valerie M.

    2015-03-01

    Quantitative methods for environmental and cost analyses of energy, industrial, and infrastructure systems are briefly introduced and surveyed, with the aim of encouraging broader utilization and development of quantitative methods in sustainable energy research. Material and energy flow analyses can provide an overall system overview. The methods of engineering economics and cost benefit analysis, such as net present values, are the most straightforward approach for evaluating investment options, with the levelized cost of energy being a widely used metric in electricity analyses. Environmental lifecycle assessment has been extensively developed, with both detailed process-based and comprehensive input-output approaches available. Optimization methods provide an opportunity to go beyond engineering economics to develop detailed least-cost or least-impact combinations of many different choices.

  4. Exploring the potential of clumped isotope thermometry on coccolith-rich sediments as a sea surface temperature proxy

    Science.gov (United States)

    Drury, Anna Joy; John, Cédric M.

    2016-10-01

    Understanding past changes in sea surface temperatures (SSTs) is crucial; however, existing proxies for reconstructing past SSTs are hindered by unknown ancient seawater composition (foraminiferal Mg/Ca and δ18O) or reflect subsurface temperatures (TEX86) or have a limited applicable temperature range (U37k'). We examine clumped isotope (Δ47) thermometry to fossil coccolith-rich material as an SST proxy, as clumped isotopes are independent of original seawater composition and applicable to a wide temperature range and coccolithophores are widespread and dissolution resistant. The Δ47-derived temperatures from 63 μm fraction removes most nonmixed layer components; however, the Δ47-derived temperatures display an unexpected slight decreasing trend with decreasing size fraction. This unexpected trend could partly arise because larger coccoliths (5-12 μm) are removed during the size fraction separation process. The c1 and <63 μm c2 Δ47-derived temperatures are comparable to concurrent U37k' SSTs. The <20, <10, and 2-5 μm c2 Δ47-derived temperatures are consistently cooler than expected. The Δ47-U37k' temperature offset is probably caused by abiotic/diagenetic calcite present in the c2 2-5 μm fraction (˜53% by area), which potentially precipitated at bottom water temperatures of ˜6°C. Our results indicate that clumped isotopes on coccolith-rich sediment fractions have potential as an SST proxy, particularly in tropical regions, providing that careful investigation of the appropriate size fraction for the region and time scale is undertaken.

  5. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    Science.gov (United States)

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  6. An improved FT-TIMS method of measuring uranium isotope ratios in the uranium-bearing particles

    International Nuclear Information System (INIS)

    Chen, Yan; Wang, Fan; Zhao, Yong-Gang; Li, Li-Li; Zhang, Yan; Shen, Yan; Chang, Zhi-Yuan; Guo, Shi-Lun; Wang, Xiao-Ming; Cui, Jian-Yong; Liu, Yu-Ang

    2015-01-01

    An improved method of Fission Track technique combined with Thermal Ionization Mass Spectrometry (FT-TIMS) was established in order to determine isotope ratio of uranium-bearing particle. Working standard of uranium oxide particles with a defined diameter and isotopic composition were prepared and used to review the method. Results showed an excellent agreement with certified values. The developed method was used to analyze isotope ratio of single uranium-bearing particle in swipe samples successfully. The analysis results of uranium-bearing particles in swipe samples accorded with the operation history of the origin. - Highlights: • The developed method was successfully applied in the analysis of real swipe sample. • Uranium-bearing particles were confined in the middle of track detector. • The fission tracks of collodion film and PC film could be confirmed each other. • The thickness of collodion film should be no more than about 60 μm. • The method could avoid losing uranium-bearing particles in the etching step.

  7. Exploring Gender Biases in a General Methods Class.

    Science.gov (United States)

    Quinn, Robert J.; Obenchain, Kathryn M.

    1999-01-01

    Describes how students in a general secondary methods course responded to a gender-neutral exam question by consistently assuming that the student in the hypothetical scenario was male. Describes the follow-up class discussion, noting students' assumptions, defensive responses, subconscious decision making, and awareness/nonawareness of their own…

  8. Mixed methods systematic review exploring mentorship outcomes in nursing academia.

    Science.gov (United States)

    Nowell, Lorelli; Norris, Jill M; Mrklas, Kelly; White, Deborah E

    2017-03-01

    The aim of this study was to report on a mixed methods systematic review that critically examines the evidence for mentorship in nursing academia. Nursing education institutions globally have issued calls for mentorship. There is emerging evidence to support the value of mentorship in other disciplines, but the extant state of the evidence in nursing academia is not known. A comprehensive review of the evidence is required. A mixed methods systematic review. Five databases (MEDLINE, CINAHL, EMBASE, ERIC, PsycINFO) were searched using an a priori search strategy from inception to 2 November 2015 to identify quantitative, qualitative and mixed methods studies. Grey literature searches were also conducted in electronic databases (ProQuest Dissertations and Theses, Index to Theses) and mentorship conference proceedings and by hand searching the reference lists of eligible studies. Study quality was assessed prior to inclusion using standardized critical appraisal instruments from the Joanna Briggs Institute. A convergent qualitative synthesis design was used where results from qualitative, quantitative and mixed methods studies were transformed into qualitative findings. Mentorship outcomes were mapped to a theory-informed framework. Thirty-four studies were included in this review, from the 3001 records initially retrieved. In general, mentorship had a positive impact on behavioural, career, attitudinal, relational and motivational outcomes; however, the methodological quality of studies was weak. This review can inform the objectives of mentorship interventions and contribute to a more rigorous approach to studies that assess mentorship outcomes. © 2016 John Wiley & Sons Ltd.

  9. Using Blogs in Qualitative Educational Research: An Exploration of Method

    Science.gov (United States)

    Harricharan, Michelle; Bhopal, Kalwant

    2014-01-01

    When compared with wider social research, qualitative educational research has been relatively slow to take up online research methods (ORMs). There is some very notable research in the area but, in general, ORMs have not achieved wide applicability in qualitative educational contexts apart from research that is inherently linked to the Internet,…

  10. A continuous flow isotope ratio mass spectrometry method for high precision determination of dissolved gas ratios and isotopic composition

    DEFF Research Database (Denmark)

    Charoenpong, C. N.; Bristow, L. A.; Altabet, M. A.

    2014-01-01

    ratio mass spectrometer (IRMS). A continuous flow of He carrier gas completely degasses the sample, and passes through the preparation and purification system before entering the IRMS for analysis. The use of this continuous He carrier permits short analysis times (less than 8 min per sample......) as compared with current high-precision methods. In addition to reference gases, calibration is achieved using air-equilibrated water standards of known temperature and salinity. Assessment of reference gas injections, air equilibrated standards, as well as samples collected in the field shows the accuracy...

  11. Exploring the ground ice recharge near permafrost table on the central Qinghai-Tibet Plateau using chemical and isotopic data

    Science.gov (United States)

    Wang, Weihua; Wu, Tonghua; Zhao, Lin; Li, Ren; Zhu, Xiaofan; Wang, Wanrui; Yang, Shuhua; Qin, Yanhui; Hao, Junmin

    2018-05-01

    Thawing permafrost on the Qinghai-Tibet Plateau (QTP) has great impacts on the local hydrological process by way of causing ground ice to thaw. Until now there is little knowledge on ground ice hydrology near permafrost table under a warming climate. This study applied stable tracers (isotopes and chloride) and hydrograph separation model to quantify the sources of ground ice near permafrost table in continuous permafrost regions of the central QTP. The results indicated that the ground ice near permafrost table was mainly supplied by active layer water and permafrost water, accounting for 58.9 to 87.0% and 13.0 to 41.1%, respectively, which implying that the active layer was the dominant source. The contribution rates from the active layer to the ground ice in alpine meadow (59 to 69%) was less than that in alpine steppe (70 to 87%). It showed well-developed hydrogeochemical depth gradients, presenting depleted isotopes and positive chemical gradients with depth within the soil layer. The effects of evaporation and freeze-out fractionation on the soil water and ground ice were evident. The results provide additional insights into ground ice sources and cycling near permafrost table in permafrost terrain, and would be helpful for improving process-based detailed hydrologic models under the occurring global warming.

  12. New on-line method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    Science.gov (United States)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-01-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us to simultaneously measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the on-line water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δD reliability. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water resulting in an artificial water background with well-known δD and δ18O values. The speleothem sample is placed into a copper tube, attached to the line and after system stabilisation is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain δD and δ18O isotopic composition of measured water aliquots. Precision is better than 1.5‰ for δD and 0.4‰ for δ18O for water measurement for an extended range (-210 to 0‰ for δD and -27 to 0‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to Isotope Ratio Mass Spectrometry (IRMS) technique.

  13. New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    Science.gov (United States)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-07-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (-210 to 0 ‰ for δ D and -27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass

  14. Determining origin in a migratory marine vertebrate: a novel method to integrate stable isotopes and satellite tracking

    Science.gov (United States)

    Vander Zanden, Hannah B.; Tucker, Anton D.; Hart, Kristen M.; Lamont, Margaret M.; Fujisaki, Ikuko; Addison, David S.; Mansfield, Katherine L.; Phillips, Katrina F.; Wunder, Michael B.; Bowen, Gabriel J.; Pajuelo, Mariela; Bolten, Alan B.; Bjorndal, Karen A.

    2015-01-01

    Stable isotope analysis is a useful tool to track animal movements in both terrestrial and marine environments. These intrinsic markers are assimilated through the diet and may exhibit spatial gradients as a result of biogeochemical processes at the base of the food web. In the marine environment, maps to predict the spatial distribution of stable isotopes are limited, and thus determining geographic origin has been reliant upon integrating satellite telemetry and stable isotope data. Migratory sea turtles regularly move between foraging and reproductive areas. Whereas most nesting populations can be easily accessed and regularly monitored, little is known about the demographic trends in foraging populations. The purpose of the present study was to examine migration patterns of loggerhead nesting aggregations in the Gulf of Mexico (GoM), where sea turtles have been historically understudied. Two methods of geographic assignment using stable isotope values in known-origin samples from satellite telemetry were compared: 1) a nominal approach through discriminant analysis and 2) a novel continuous-surface approach using bivariate carbon and nitrogen isoscapes (isotopic landscapes) developed for this study. Tissue samples for stable isotope analysis were obtained from 60 satellite-tracked individuals at five nesting beaches within the GoM. Both methodological approaches for assignment resulted in high accuracy of foraging area determination, though each has advantages and disadvantages. The nominal approach is more appropriate when defined boundaries are necessary, but up to 42% of the individuals could not be considered in this approach. All individuals can be included in the continuous-surface approach, and individual results can be aggregated to identify geographic hotspots of foraging area use, though the accuracy rate was lower than nominal assignment. The methodological validation provides a foundation for future sea turtle studies in the region to inexpensively

  15. Development of an enantiomer-specific stable carbon isotope analysis (ESIA) method for assessing the fate of α-hexachlorocyclo-hexane in the environment.

    Science.gov (United States)

    Badea, Silviu-Laurentiu; Vogt, Carsten; Gehre, Matthias; Fischer, Anko; Danet, Andrei-Florin; Richnow, Hans-Hermann

    2011-05-30

    α-Hexachlorocyclohexane (α-HCH) is the only chiral isomer of the eight 1,2,3,4,5,6-HCHs and we have developed an enantiomer-specific stable carbon isotope analysis (ESIA) method for the evaluation of its fate in the environment. The carbon isotope ratios of the α-HCH enantiomers were determined for a commercially available α-HCH sample using a gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) system equipped with a chiral column. The GC-C-IRMS measurements revealed δ-values of -32.5 ± 0.8‰ and -32.3 ± 0.5‰ for (-) α-HCH and (+) α-HCH, respectively. The isotope ratio of bulk α-HCH was estimated to be -32.4 ± 0.6‰ which was in accordance with the δ-values obtained by GC-C-IRMS (-32.7 ± 0.2‰) and elemental analyzer-isotope ratio mass spectrometry (EA-IRMS) of the bulk α-HCH (-32.1 ± 0.1‰). The similarity of the isotope ratio measurements of bulk α-HCH by EA-IRMS and GC-C-IRMS indicates the accuracy of the chiral GC-C-IRMS method. The linearity of the α-HCH ESIA method shows that carbon isotope ratios can be obtained for a signal size above 100 mV. The ESIA measurements exhibited standard deviations (2σ) that were mostly IRMS method, the isotope compositions of individual enantiomers in biodegradation experiments of α-HCH with Clostridium pasteurianum and samples from a contaminated field site were determined. The isotopic compositions of the α-HCH enantiomers show a range of enantiomeric and isotope patterns, suggesting that enantiomeric and isotope fractionation can serve as an indicator for biodegradation and source characterization of α-HCH in the environment. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Lead-lead isotope method. Application to migmatites and associaded rocks of the region of Sao Jose dos Campos, SP

    International Nuclear Information System (INIS)

    Babinski, M.

    1988-01-01

    Establishment of chemical and analytical procedures, preparation and purification of reagents and the mounting of a clean laboratory (class 100) for the Pb-Pb isotope dating of whole rock and mineral samples are discussed in this work. Two different methods of dissolution of rock samples and chemical separation of lead using anionic resin were tried in a conventional chemical laboratory using analytical grade reagents. The samples analysed were paleossome and neossome of migmatites from Sao Jose dos Campos, SP, and from the results obtained the analytical method to be employed was chosen. The results obtained by this method agree well with those of the Geochronology Laboratory at Oxford, for the same samples. Applying the established analytical procedure, migmatites and associated gneisses from the region of Sao Jose dos Campos were dated by Pb/Pb method. Some of the samples were also dated by Rb-Sr method. The lead-lead isochron age of 2355 +- 85 M.a. (μ 1 = 8.33) for the paleossome may be interpreted as the age of the metamorphism for these rocks, which were formed probably during the Archean. The age data for the phacoidal gneisses show a similar geological evolution, whereas the 2414 +- 800 M.A. Pb-Pb isochron age for the protomylonitic gneisses indicates a disturbed Pb-Pb isotope system. The neossome samples define a Pb-Pb isochron age of 1388 +- 290 M.A. (μ1 = 8.15), which may be interpreted as the age of migmatization. The calculated Pb-Pb ages for two alkali feldspars from the migmatites are devoid of any geological significance. The age values obtained by the Rb-Sr isotope system for the neossome and paleossome of the migmatites agree with the Pb/Pb data within experimental errors. However, the study shows that results of the Rb-Sr data alone cannot be interpreted unambiguously with out comparison with data from other isotope systems. (author) [pt

  17. Standard test method for isotopic analysis of hydrolyzed uranium hexafluoride and uranyl nitrate solutions by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This method applies to the determination of isotopic composition in hydrolyzed nuclear grade uranium hexafluoride. It covers isotopic abundance of 235U between 0.1 and 5.0 % mass fraction, abundance of 234U between 0.0055 and 0.05 % mass fraction, and abundance of 236U between 0.0003 and 0.5 % mass fraction. This test method may be applicable to other isotopic abundance providing that corresponding standards are available. 1.2 This test method can apply to uranyl nitrate solutions. This can be achieved either by transforming the uranyl nitrate solution to a uranyl fluoride solution prior to the deposition on the filaments or directly by depositing the uranyl nitrate solution on the filaments. In the latter case, a calibration with uranyl nitrate standards must be performed. 1.3 This test method can also apply to other nuclear grade matrices (for example, uranium oxides) by providing a chemical transformation to uranyl fluoride or uranyl nitrate solution. 1.4 This standard does not purport to address al...

  18. Environmental hydrochemical and stabile isotope methods used to characterise the relation between karst water and surface water

    Directory of Open Access Journals (Sweden)

    Romeo Eftimi

    2017-03-01

    Full Text Available Karst aquifers are characterized by high heterogeneity of groundwater flow. The classical study methods such as boreholes, pumping tests, and point observations give important data but cannot be extended to the entire aquifer. However the environmental hydrochemical and stabile isotope methods could give important information about large scale aquifer characterization. Some study examples from Albania, shown in this paper, demonstrate the successful application of the isotope methods, which are more powerful if applied in combination with hydrochemical ones, for the identification of the karst water recharge sources. Among the isotope methods the altitude effect seems to be more indicative for the solution of the problem concerned. For characterising the lithology of karst rocks and the physical aspects of karst aquifers (type of groundwater flow the combined use of some hydrochemical parameters like the water conductivity, total hardness, ionic ratios rCa/ rMg, rSO4/r/mg, CO2 pressure and the indexes of calcite and (Sic and of dolomite saturation (Sid, result very useful.

  19. Use of radioanalytical methods for determination of uranium, neptunium, plutonium, americium and curium isotopes in radioactive wastes

    International Nuclear Information System (INIS)

    Geraldo, Bianca

    2012-01-01

    Activated charcoal is a common type of radioactive waste that contains high concentrations of fission and activation products. The management of this waste includes its characterization aiming the determination and quantification of the specific radionuclides including those known as Difficult-to-Measure Radionuclides (RDM). The analysis of the RDM's generally involves complex radiochemical analysis for purification and separation of the radionuclides, which are expensive and time-consuming. The objective of this work was to define a methodology for sequential analysis of the isotopes of uranium, neptunium, plutonium, americium and curium present in a type of radioactive waste, evaluating chemical yield, analysis of time spent, amount of secondary waste generated and cost. Three methodologies were compared and validated that employ ion exchange (TI + EC), extraction chromatography (EC) and extraction with polymers (ECP). The waste chosen was the activated charcoal from the purification system of primary circuit water cooling the reactor IEA-R1. The charcoal samples were dissolved by acid digestion followed by purification and separation of isotopes with ion exchange resins, extraction and chromatographic extraction polymers. Isotopes were analyzed on an alpha spectrometer, equipped with surface barrier detectors. The chemical yields were satisfactory for the methods TI + EC and EC. ECP method was comparable with those methods only for uranium. Statistical analysis as well the analysis of time spent, amount of secondary waste generated and cost revealed that EC method is the most effective for identifying and quantifying U, Np, Pu, Am and Cm present in charcoal. (author)

  20. Uniform deposition of uranium hexafluoride (UF6): Standardized mass deposits and controlled isotopic ratios using a thermal fluorination method.

    Science.gov (United States)

    McNamara, Bruce K; O'Hara, Matthew J; Casella, Andrew M; Carter, Jennifer C; Addleman, R Shane; MacFarlan, Paul J

    2016-07-01

    We report a convenient method for the generation of volatile uranium hexafluoride (UF6) from solid uranium oxides and other U compounds, followed by uniform deposition of low levels of UF6 onto sampling coupons. Under laminar flow conditions, UF6 is shown to interact with surfaces within a fixed reactor geometry to a highly predictable degree. We demonstrate the preparation of U deposits that range between approximately 0.01 and 500ngcm(-2). The data suggest the method can be extended to creating depositions at the sub-picogramcm(-2) level. The isotopic composition of the deposits can be customized by selection of the U source materials and we demonstrate a layering technique whereby two U solids, each with a different isotopic composition, are employed to form successive layers of UF6 on a surface. The result is an ultra-thin deposit that bears an isotopic signature that is a composite of the two U sources. The reported deposition method has direct application to the development of unique analytical standards for nuclear safeguards and forensics. Further, the method allows access to very low atomic or molecular coverages of surfaces. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Application of isotopic and hydro-geochemical methods in identifying sources of mine inrushing water

    Institute of Scientific and Technical Information of China (English)

    Dou Huiping; Ma Zhiyuan; Cao Haidong; Liu Feng; Hu Weiwei; Li Ting

    2011-01-01

    Isotopic and hydro-geochemical surveys were carried out to identify the source of mine inrushing water at the #73003 face in the Laohutai Mine.Based on the analysis of isotopes and hydro-chemical features of surface water,groundwater from different levels and the inrushing water,a special relationship between water at the #73003 face and cretaceous water has been found.The results show that the isotopic and hydro-chemical features of the inrushing water are completely different from those of other groundwater bodies,except for the cretaceous water.The isotopic and hydrochemical characteristics of cretaceous water are similar to the inrushing water of the #73003 face,which aided with obtaining the evidence for the possible source of the inrushing water at the #73003 face.The isotope calculations show that the inrushing water at the #73003 face is a mixture of cretaceous water and Quaternary water,water from the cretaceous conglomerate is the main source,accounting for 67% of the inrushing water,while the Quaternary water accounts for 33%.The conclusion is also supported by a study of inrushing-water channels and an active fault near the inrushing-water plot on the #73003 face.

  2. Rapid method for the sequential measurement of isotopes of Am and Pu in liquid matrices by alpha spectrometry

    International Nuclear Information System (INIS)

    Mantero Cabrera, J.

    2014-01-01

    : In radiological emergencies it's necessary a fast response from the laboratories in the quantification of certain radionuclides, in order to take decisions. In these cases, is the reaction time the key parameter to consider (without neglecting the quality of the measurement). In this work, it is shown a method for aqueous matrices that generates Pu and Am isotopes sources in one single day of work, to be measured subsequently by alpha spectrometry. The developed methodology has been validated through its application to reference samples and also taking part intercom- parison exercises, having in both cases, satisfactory results. This way, we check the validity of this fast method that let us generate in 24 hours (since the sample arrives our laboratory), one measurement with a Minimun Detectable Activity (MDA) of about 0.004Bq/L for Pu and Am isotopes in liquid matrices. [es

  3. Estimation of serum thyroglobulin using isotopic and non-isotopic methods: a comparison between RIA, IRMA and ELISA

    International Nuclear Information System (INIS)

    Ajay Kumar; Velumani, A.; Dandekar, S.R.; Shah, D.H.; Rajashekharrao, B.

    1997-01-01

    Three in-house immunoassays viz, RIA, IRMA and ELISA for estimation of serum Tg were compared for their assay characteristics and clinical utility. The inter- and intra-assay coefficient of variations of RIA and IRMA were comparable and were marginally better than that of ELISA. The sensitivity of IRMA was superior to RIA which in turn was superior than ELISA. Incubation time for both IRMA and ELISA was 4 h as compared to 90 h required for RIA. The enzyme conjugated antibody had longest shelf-life (9 months) followed by radiolabeled antibody (3 months) while radiolabeled Tg had shortest shelf-life (3 weeks). There was no interference from circulating anti-Tg autoantibodies in the RIA of Tg as compared to a gross underestimation observed in both sandwich methods. Assays correlated well with each other (r > 0.85, n=200) and had suitable clinical utility (sensitivity > 93% and specificity > 89%). Each assay though had its own merits and demerits, yet it served the clinical utility for an effective management of patients with differentiated thyroid carcinoma. (author)

  4. Determination of endogenous manganese excretion in broiler chicks by an isotope-dilution method

    International Nuclear Information System (INIS)

    Weigand, E.; Kirchgessner, M.; Kilic, A.

    1988-01-01

    A tracer study with broiler chicks was conducted to determine endogenous Mn excretion in response to graded levels of dietary Mn supply by the isotope-dilution method. Starting with 46 day-old chicks, low-Mn diets were fed for 12 days before 8 chicks were slaughtered for assessing the intial Mn status and 38 chicks each were given an intramuscular injection of 555 kBq 54 Mn. Four groups of six birds each were fed, one bird per cage, diets containing 2.8, 9.1, 25.8, and 59.7 ppm Mn for 16 days before slaughter and carcass analyses. Two groups of 7 birds were fed the diets with 9.1 and 25.8 ppm Mn for 8 days. Mn supply significantly affected 54 Mn excretion activity of distribution among various body organs, especially the liver. The specific activity of Mn in excreta and in whole-body declined exponentially with time and differed between groups. Endogenous Mn in excreta was estimated on the basis that the specific activity of excreta Mn from day 9 to 12 and day 13 to 16 was reflected, on the average, by that of liver Mn on day 10 and 14, respectively. It averaged in the order of increasing Mn supply 12.5 vs. 12.0; 7.7 vs. 8.5; 3.9 vs. 4.3, and 2.0 vs. 2.3% of total excreta Mn. Total Mn excretion from day 9 to 16 averaged 88.9, 95.0, 97.9. and 98.9% of Mn intake. (author)

  5. Isotope Methods in Determining The Water Budget Elements; Su Buetcesi Elemanlarinin Bulunmasinda Izotop Yoentemi

    Energy Technology Data Exchange (ETDEWEB)

    Oezaydin, V [DSI, Technical Research and Quality Control Department, Ankara (Turkey)

    2002-07-01

    One of the main aims of the water engineers is the determination of the inflows to and outflows from a natural or artificial lake. According to the classical water balance equation inflows (precipitation on the lake surface, surface and subsurface inflows) mines the outflows (evaporation from lake surface, surface and subsurface outflows) should be equal to the volume change in a specified time interval. With the classical water budget equation it is possible to determine the total absolute subsurface inflow mines outflow but it is not possible to determine them separately. The two unknowns could be determined with one more equation. The isotopes, oxygen-18, deuterium or tritium, which are naturally present in water, could provide the extra equation by writing the isotopic mass balance equation. In this study, the theoretical background of isotope technique and application to Mogan Lake, will be presented which is used in determining the water budget of lakes.

  6. Trojan Horse Method: A tool to explore electron screening effect

    Energy Technology Data Exchange (ETDEWEB)

    Pizzone, R G; Spitaleri, C; Cherubini, S; Cognata, M La; Lamia, L; Romano, S; Sergi, M L [Laboratori Nazionali del Sud-INFN, Catania (Italy) and Dipartimento di Metodologie Fisiche e Chimiche per l' Ingegneria, Universita di Catania, Catania (Italy); Rolfs, C; Strieder, F [Ruhr Universitaet Bochum (Germany); Burjan, V; Kroha, V; Mrazek, J [Cyclotron Institute, Academy of Science, Rez (Czech Republic); Li, C; Wen, Q; Zhou, S [CIAE, Beijing (China); Tumino, A, E-mail: rgpizzone@lns.infn.i [Universita Kore, Erma (Italy)

    2010-01-01

    Owing the presence of the Coulomb barrier at astrophysically relevant energies, it is very difficult, or sometimes impossible to measure reaction rates for charged particle induced reactions. Moreover due to the presence of the electron screening effect in direct measurements, the relevant nuclear input for astrophysics, i.e. the bare nucleus S(E)-factor, can hardly be extracted. This is why different indirect techniques are being used along with direct measurements. The THM is an unique: indirect technique which allows one to measure reactions cross sections of astrophysical interest down the thermal energies typical of the different scenarios. The basic principle and a review of the main applications of the Trojan Horse Method are given. The applications aiming at the extraction of the bare S{sub b}(E) astrophysical factor and electron screening potentials U{sub e} for several two body processes are discussed.

  7. Exploration of submarine wake and powering performance using CFD method

    International Nuclear Information System (INIS)

    Huizhi, Y.; Hongcui, S.; Nan, Z.; Renyou, Y.; Liangmei, Y.

    2005-01-01

    In response to the needs of better design and less time, Computational Fluid Dynamic(CFD) methods have become an impartible part in the ship design, especially in the earlier design phases. In this paper FLUENT software was used to predict the wake character and powering performance of submarine at model scale. By an effective combination of the block topology, grid, turbulence model and validation, the simulation scheme was developed and applied to the predictions of multiple designs and optimizations of the earlier submarine design iterations. The incompressible RANS equations with different turbulence models were solved. To handle the block interface between the propeller and submarine stern, sliding girds in multiple blocks were employed, unstructural grids were used in the block around the propeller. Submarine with/without stator and/or propeller were studied. The flow feature, forces and powering performance at various conditions were calculated. The results were compared with experimental data, and a good agreement was obtained. (author)

  8. Isotopic data from proterozoic sediment-hosted sulfide deposits of Brazil: Implications for their metallogenic evolution and for mineral exploration

    International Nuclear Information System (INIS)

    Misi, Aroldo; Coelho, Carlos E.S.; Franca Rocha, Washington J.S.; Gomez, Adriana S.R.; Cunha, Iona A.; Iyer, Sundaram S.; Tassinari, Colombo C.G.; Kyle, J. Richard

    1998-01-01

    Geological, petrographic, fluid inclusions studies and isotopic data of seven Proterozoic sediment-hosted Pb-Zn-Ag sulfide deposits of Brazil, permit the estimation of the age of the hosting sequence and the mineralization, the nature of the sulfur and metal sources, the temperature range of sulfide formation and the environment of deposition of the mineral deposits. The studies suggest that they were formed during periods of extensional tectonics: Growth faults or reactivated basement faults were responsible for localized circulation of metal-bearing fluids within the sedimentary sequences. In most cases, sulfides were formed by the reduction of sedimentary sulfates. Linear structures are important controls for sulfide concentration in these Proterozoic basins. (author)

  9. Uniform deposition of uranium hexafluoride (UF6): Standardized mass deposits and controlled isotopic ratios using a thermal fluorination method

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Bruce K.; O’Hara, Matthew J.; Casella, Andrew M.; Carter, Jennifer C.; Addleman, R. Shane; MacFarlan, Paul J.

    2016-07-01

    Abstract: We report a convenient method for the generation of volatile uranium hexafluoride (UF6) from solid uranium oxides and other uranium compounds, followed by uniform deposition of low levels of UF6 onto sampling coupons. Under laminar flow conditions, UF6 is shown to interact with surfaces within the chamber to a highly predictable degree. We demonstrate the preparation of uranium deposits that range between ~0.01 and 470±34 ng∙cm-2. The data suggest the method can be extended to creating depositions at the sub-picogram∙cm-2 level. Additionally, the isotopic composition of the deposits can be customized by selection of the uranium source materials. We demonstrate a layering technique whereby two uranium solids, each with a different isotopic composition, are employed to form successive layers of UF6 on a surface. The result is an ultra-thin deposit of UF6 that bears an isotopic signature that is a composite of the two uranium sources. The reported deposition method has direct application to the development of unique analytical standards for nuclear safeguards and forensics.

  10. Measurement of dinitrogen fixation by Biological soil crust (BSC) from the Sahelian zone: an isotopic method.

    Science.gov (United States)

    Ehrhardt, F.; Alavoine, G.; Bertrand, I.

    2012-04-01

    Amongst the described ecological roles of Biological Soil Crust, N fixation is of importance for soil fertility, especially in arid and semi-arid ecosystems with low inputs. In BSC, the quantification of N fixation fluxes using an indirect method is widespread, usually with the Acetylene Reduction Assay (ARA) which consists in measuring the nitrogenase activity through the process of acetylene reduction into ethylene. A converting factor, still discussed in the literature and greatly depending of the constitutive organisms of the BSC, is the tool used to convert the amount of reduced ethylene into quantitative fixed Nitrogen. The aim of this poster is to describe an isotopic direct method to quantify the atmospheric dinitrogen fixation fluxes in BSC, while minimizing the variability due to manipulations. Nine different BSC from the Sahelian zone were selected and placed in an incubation room at 28° C in dark and light conditions during three days, while moisture equivalent to pF=2 was regularly adjusted using the gravimetric method with needles and deionized water, in order to activate and reach a dynamic stability of their metabolisms. Subsequently, each crust was placed into a gas-tight glass vial for incubation with a reconstituted 15N2 enriched atmosphere (31.61 % atom 15N, while the proportion of each main gas present in the air was conserved, i.e. 78% N2, 21% O2 and 0.04% CO2). Principal difficulties are to guarantee the airtighness of the system, to avoid crust desiccation and to keep the crust metabolically active under stable conditions for six hours. Several tests were performed to determine the optimum time for 15N2 incubation. Three replicated control samples per crust were also stabilized for three days and then dried at 105° C, without any incubation with 15N2 enriched atmosphere. Total N and 15N were then measured in the grounded (80μm) and dried (105° C) crust, using a Flash EA elemental analyzer (Eurovector, Milan, Italy) coupled to a Delta

  11. Error analysis of isotope dilution mass spectrometry method with internal standard

    International Nuclear Information System (INIS)

    Rizhinskii, M.W.; Vitinskii, M.Y.

    1989-02-01

    The computation algorithms of the normalized isotopic ratios and element concentration by isotope dilution mass spectrometry with internal standard are presented. A procedure based on the Monte-Carlo calculation is proposed for predicting the magnitude of the errors to be expected. The estimation of systematic and random errors is carried out in the case of the certification of uranium and plutonium reference materials as well as for the use of those reference materials in the analysis of irradiated nuclear fuels. 4 refs, 11 figs, 2 tabs

  12. New method for the hydrogen isotope exchange reaction in a hydrophobic catalyst bed

    International Nuclear Information System (INIS)

    Asakura, Y.; Kikuchi, M.; Yusa, H.

    1982-01-01

    To improve the isotope exchange reaction efficiency between water and hydrogen, a new reactor in which water mists and hydrogen gas react cocurrently was studied. To apply this to the enrichment of tritium in heavy water, a dual temperature isotope exchange reactor which is composed of cocurrent low temperature reactors and the usual countercurrent high temperature reactor was proposed and analyzed using a McCabe-Thiele diagram. By utilizing cocurrent reactors, in combination, the necessary catalyst volume can be reduced to one-tenth as compared with the usual countercurrent low temperature reactor. 17 refs

  13. A novel methodology to investigate isotopic biosignatures

    Science.gov (United States)

    Horner, T. J.; Lee, R. B. Y.; Henderson, G. M.; Rickaby, R. E. M.

    2012-04-01

    An enduring goal of trace metal isotopic studies of Earth History is to find isotopic 'fingerprints' of life or of life's individual physiochemical processes. Generally, such signatures are sought by relating an isotopic effect observed in controlled laboratory conditions or a well-characterized environment to a more complex system or the geological record. However, such an approach is ultimately limited because life exerts numerous isotopic fractionations on any one element so it is hard to dissect the resultant net fractionation into its individual components. Further, different organisms, often with the same apparent cellular function, can express different isotopic fractionation factors. We have used a novel method to investigate the isotopic fractionation associated with a single physiological process-enzyme specific isotopic fractionation. We selected Cd isotopes since only one biological use of Cd is known, CdCA (a Cd/Zn carbonic anhydrase from the coastal diatom T. Weissflogii). Thus, our investigation can also inform the long standing mystery as to why this generally toxic element appears to have a nutrient-like dissolved isotopic and concentration profile in the oceans. We used the pET-15b plasmid to insert the CdCA gene into the E. coli genome. There is no known biochemical function for Cd in E. coli, making it an ideal vector for studying distinct physiological processes within a single organism. The uptake of Cd and associated isotopic fractionation was determined for both normal cells and those expressing CdCA. It was found that whole cells always exhibited a preference for the light isotopes of Cd, regardless of the expression of CdCA; adsorption of Cd to cell surfaces was not seen to cause isotopic fractionation. However, the cleaning procedure employed exerted a strong control on the observed isotopic composition of cells. Using existing protein purification techniques, we measured the Cd isotopic composition of different subcellular fractions of E

  14. Exploring FeSe-based superconductors by liquid ammonia method

    International Nuclear Information System (INIS)

    Ying Tian-Ping; Wang Gang; Jin Shi-Feng; Shen Shi-Jie; Zhang Han; Zhou Ting-Ting; Lai Xiao-Fang; Wang Wan-Yan; Chen Xiao-Long

    2013-01-01

    Our recent progress on the preparation of a series of new FeSe-based superconductors and the clarification of SC phases in potassium-intercalated iron selenides are reviewed here. By the liquid ammonia method, metals Li, Na, Ca, Sr, Ba, Eu, and Yb are intercalated in between FeSe layers and form superconductors with transition temperatures of 30 K∼46 K, which cannot be obtained by high-temperature routes. In the potassium-intercalated iron selenides, we demonstrate that at least two SC phases exist, K x Fe 2 Se 2 (NH 3 ) y (x ≈ 0.3 and 0.6), determined mainly by the concentration of potassium. NH 3 has little, if any, effect on superconductivity, but plays an important role in stabilizing the structures. All these results provide a new starting point for studying the intrinsic properties of this family of superconductors, especially for their particular electronic structures. (topical review - iron-based high temperature superconductors)

  15. Exploring nurse leader fatigue: a mixed methods study.

    Science.gov (United States)

    Steege, Linsey M; Pinekenstein, Barbara J; Arsenault Knudsen, Élise; Rainbow, Jessica G

    2017-05-01

    To describe hospital nurse leaders' experiences of fatigue. Fatigue is a critical challenge in nursing. Existing literature focuses on staff nurse fatigue, yet nurse leaders are exposed to high demands that may contribute to fatigue and associated risks to patient, nurse and organisational outcomes. A mixed method approach comprising semi-structured interviews and the Occupational Fatigue Exhaustion Recovery scale with 21 nurse administrators (10 nurse managers and 11 nurse executives) from hospitals in a Midwestern state. Most nurse leaders experience fatigue; nurse managers reported higher levels of chronic fatigue. Participants identified multiple sources of fatigue including 24 h accountability and intensity of role expectations, and used a combination of wellness, restorative, social support and boundary setting strategies to cope with fatigue. The consequences of nurse leader fatigue include an impact on decision-making, work-life balance and turnover intent. The high prevalence of nurse leader fatigue could impact the turnover intent of nurse administrators and quality of care. This study highlights the significance and consequences of nurse leader fatigue. As health care organisations continue to raise awareness and establish systems to reduce nurse fatigue, policies and programmes must be adapted to address nurse leader fatigue. © 2017 John Wiley & Sons Ltd.

  16. Stable isotope analyses of oxygen (18O:17O:16O) and chlorine (37Cl:35Cl) in perchlorate: reference materials, calibrations, methods, and interferences

    Science.gov (United States)

    Böhlke, John Karl; Mroczkowski, Stanley J.; Sturchio, Neil C.; Heraty, Linnea J.; Richman, Kent W.; Sullivan, Donald B.; Griffith, Kris N.; Gu, Baohua; Hatzinger, Paul B.

    2017-01-01

    RationalePerchlorate (ClO4−) is a common trace constituent of water, soils, and plants; it has both natural and synthetic sources and is subject to biodegradation. The stable isotope ratios of Cl and O provide three independent quantities for ClO4− source attribution and natural attenuation studies: δ37Cl, δ18O, and δ17O (or Δ17O or 17Δ) values. Documented reference materials, calibration schemes, methods, and interferences will improve the reliability of such studies.MethodsThree large batches of KClO4 with contrasting isotopic compositions were synthesized and analyzed against VSMOW-SLAP, atmospheric O2, and international nitrate and chloride reference materials. Three analytical methods were tested for O isotopes: conversion of ClO4− to CO for continuous-flow IRMS (CO-CFIRMS), decomposition to O2 for dual-inlet IRMS (O2-DIIRMS), and decomposition to O2 with molecular-sieve trap (O2-DIIRMS+T). For Cl isotopes, KCl produced by thermal decomposition of KClO4 was reprecipitated as AgCl and converted into CH3Cl for DIIRMS.ResultsKClO4 isotopic reference materials (USGS37, USGS38, USGS39) represent a wide range of Cl and O isotopic compositions, including non-mass-dependent O isotopic variation. Isotopic fractionation and exchange can affect O isotope analyses of ClO4− depending on the decomposition method. Routine analyses can be adjusted for such effects by normalization, using reference materials prepared and analyzed as samples. Analytical errors caused by SO42−, NO3−, ReO42−, and C-bearing contaminants include isotope mixing and fractionation effects on CO and O2, plus direct interference from CO2 in the mass spectrometer. The results highlight the importance of effective purification of ClO4− from environmental samples.ConclusionsKClO4 reference materials are available for testing methods and calibrating isotopic data for ClO4− and other substances with widely varying Cl or O isotopic compositions. Current ClO4−extraction, purification

  17. Fast crawling methods of exploring content distributed over large graphs

    KAUST Repository

    Wang, Pinghui

    2018-03-15

    Despite recent effort to estimate topology characteristics of large graphs (e.g., online social networks and peer-to-peer networks), little attention has been given to develop a formal crawling methodology to characterize the vast amount of content distributed over these networks. Due to the large-scale nature of these networks and a limited query rate imposed by network service providers, exhaustively crawling and enumerating content maintained by each vertex is computationally prohibitive. In this paper, we show how one can obtain content properties by crawling only a small fraction of vertices and collecting their content. We first show that when sampling is naively applied, this can produce a huge bias in content statistics (i.e., average number of content replicas). To remove this bias, one may use maximum likelihood estimation to estimate content characteristics. However, our experimental results show that this straightforward method requires to sample most vertices to obtain accurate estimates. To address this challenge, we propose two efficient estimators: special copy estimator (SCE) and weighted copy estimator (WCE) to estimate content characteristics using available information in sampled content. SCE uses the special content copy indicator to compute the estimate, while WCE derives the estimate based on meta-information in sampled vertices. We conduct experiments on a variety of real-word and synthetic datasets, and the results show that WCE and SCE are cost effective and also “asymptotically unbiased”. Our methodology provides a new tool for researchers to efficiently query content distributed in large-scale networks.

  18. Basic features of boron isotope separation by SILARC method in the two-step iterative static model

    Science.gov (United States)

    Lyakhov, K. A.; Lee, H. J.

    2013-05-01

    In this paper we develop a new static model for boron isotope separation by the laser assisted retardation of condensation method (SILARC) on the basis of model proposed by Jeff Eerkens. Our model is thought to be adequate to so-called two-step iterative scheme for isotope separation. This rather simple model helps to understand combined action on boron separation by SILARC method of all important parameters and relations between them. These parameters include carrier gas, molar fraction of BCl3 molecules in carrier gas, laser pulse intensity, gas pulse duration, gas pressure and temperature in reservoir and irradiation cells, optimal irradiation cell and skimmer chamber volumes, and optimal nozzle throughput. A method for finding optimal values of these parameters based on some objective function global minimum search was suggested. It turns out that minimum of this objective function is directly related to the minimum of total energy consumed, and total setup volume. Relations between nozzle throat area, IC volume, laser intensity, number of nozzles, number of vacuum pumps, and required isotope production rate were derived. Two types of industrial scale irradiation cells are compared. The first one has one large throughput slit nozzle, while the second one has numerous small nozzles arranged in parallel arrays for better overlap with laser beam. It is shown that the last one outperforms the former one significantly. It is argued that NO2 is the best carrier gas for boron isotope separation from the point of view of energy efficiency and Ar from the point of view of setup compactness.

  19. Comparison of a Label-Free Quantitative Proteomic Method Based on Peptide Ion Current Area to the Isotope Coded Affinity Tag Method

    Directory of Open Access Journals (Sweden)

    Young Ah Goo

    2008-01-01

    Full Text Available Recently, several research groups have published methods for the determination of proteomic expression profiling by mass spectrometry without the use of exogenously added stable isotopes or stable isotope dilution theory. These so-called label-free, methods have the advantage of allowing data on each sample to be acquired independently from all other samples to which they can later be compared in silico for the purpose of measuring changes in protein expression between various biological states. We developed label free software based on direct measurement of peptide ion current area (PICA and compared it to two other methods, a simpler label free method known as spectral counting and the isotope coded affinity tag (ICAT method. Data analysis by these methods of a standard mixture containing proteins of known, but varying, concentrations showed that they performed similarly with a mean squared error of 0.09. Additionally, complex bacterial protein mixtures spiked with known concentrations of standard proteins were analyzed using the PICA label-free method. These results indicated that the PICA method detected all levels of standard spiked proteins at the 90% confidence level in this complex biological sample. This finding confirms that label-free methods, based on direct measurement of the area under a single ion current trace, performed as well as the standard ICAT method. Given the fact that the label-free methods provide ease in experimental design well beyond pair-wise comparison, label-free methods such as our PICA method are well suited for proteomic expression profiling of large numbers of samples as is needed in clinical analysis.

  20. A versatile method for simultaneous stable carbon isotope analysis of DNA and RNA nucleotides by liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Brasser, J.; de Ruiter, G.; Houtekamer, M.; Bolhuis, H.; Stal, L.J.; Boschker, H.T.S.

    2014-01-01

    RATIONALELiquid chromatography/isotope ratio mass spectrometry (LC/IRMS) is currently the most accurate and precise technique for the measurement of compound-specific stable carbon isotope ratios (C-13/C-12) in biological metabolites, at their natural abundance. However, until now this technique

  1. Stable isotope fingerprinting: a novel method for identifying plant, fungal, or bacterial origins of amino acids

    Science.gov (United States)

    Thomas Larsen; D. Lee Taylor; Mary Beth Leigh; Diane M. O' Brien

    2009-01-01

    Amino acids play an important role in ecology as essential nutrients for animals and as currencies in symbiotic associations. Here we present a new approach to tracing the origins of amino acids by identifying unique patterns of carbon isotope signatures generated by amino acid synthesis in plants, fungi, and bacteria ("13C fingerprints...

  2. Method to separate various isotopes in compounds by means of laser radiation

    International Nuclear Information System (INIS)

    Meyer-Kretschmer, G.; Jetter, H.; Toennies, P.

    1980-01-01

    The uranium hexafluoride together with an inert addition gas is cooled down below 50 K by adiabatic expansion, then the state of oscillation of the molecules is changed specifically for each isotope using laser light, and subsequently positive ions are produced by means of an electron beam. The ions are removed from the gas by means of an electric field. (DG) [de

  3. Study by lead isotope method of a vein : Sobrado of the Boquira mine (Bahia State, Brazil)

    International Nuclear Information System (INIS)

    Cassedanne, J.P.; Duthou, J.-L.; Clermont-Ferrand Univ., 63

    1981-01-01

    Fourteen samples of galena from the Sobrado vein, Boquira mine (Bahia) are analysed. Lead isotope compositions show an irregular variation from the central part to the extremidades. They are the result of a mixture of lead from normal galenas and lead which aparent U/Pb ratio are higher. (ARHC) [pt

  4. Quantitative SIMS measurement of high concentration of boron in silicon (up to 20 at.%) using an isotopic comparative method

    International Nuclear Information System (INIS)

    Dubois, Christiane; Prudon, Gilles; Gautier, Brice; Dupuy, Jean-Claude

    2008-01-01

    Highly boron doped (up to 20 at.%) silicon samples have been analysed by SIMS with the aim of quantifying the boron concentration in a range where the dilute regime may not be valid any more. An original method is used based on the simultaneous analysis of two different isotopes, namely 10 B and 11 B, in order that the known concentration of the first isotope (initially present with a far lower, constant concentration) is the basis of the quantification of the concentration of the second, present with a very high dose. Argon and oxygen beams have been used and conclusions are drawn about the presence of matrix effects in the case of the analysis of highly doped samples. It appears that only the use of a 8 keV O 2 + beam leads to a significant matrix effect, whereas it is nearly absent in the case of an analysis under 8 keV Ar + beam. The proposed method may be applied to any element showing at least two isotopes in any binary alloys under any primary beam

  5. Validation of methods to measure uranium isotopes using magnetic sector mass spectrometry with inductively coupled plasma source

    International Nuclear Information System (INIS)

    Hernandez M, H.; Rios L, M. J.; Romero G, E. T.

    2017-10-01

    The mass spectrometry technique with inductively coupled plasma source (Icp-Ms) has been widely used to measure isotopic ratios of elements toxic to human health. Reason for which, in this work several measurement methods for the analysis of uranium isotopes in different matrices were implemented using magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). Groundwater, sediment, soil and urine were the matrices analyzed, which were supplied by intercomparison tests conducted by the IAEA and Association for the Promotion of Quality Control of Medical Biology Analysis in Radio-toxicology. The procedures used in the treatment of soil, sediment and water samples were based on US EPA methods. In the case of the urine sample, the preparation was rapid (1:20 dilution). The average of the results obtained in yield of each matrix was 94, 71, 72 and 78% for water, urine, soil and sediment respectively. In addition, the precision in terms of standard relative deviation was less than 5% and the accuracy was less than 4%. In conclusion, the Icp-SFMS is a very sensitive technique for measuring isotopes of U in different matrices. However, careful tuning is necessary, especially in the mass regions of interest 234, 235 and 238 if an external quantification is considered using natural U solutions. (Author)

  6. The method for production of high purity carrier free ortophosphoric acid labeled with isotopes Phosphorus-32 and Phosphorus-33

    International Nuclear Information System (INIS)

    Abdukayumov, M.N.; Abdusalyamov, A.N.; Chistyakov, P.G.; Yuldashev, B.S.

    2001-01-01

    Extensive application for various radioactive isotopes was found in an extremity of the 20-Th century in a science and production. Labeled compounds are used with growing effectiveness in a molecular biology, gene engineering, medicine and other areas. Phosphorus-32 and Phosphorus-33 isotopes as a different labeled compounds that are used mainly in molecular biology are produced at the Radiopreparat enterprise of the Institute of Nuclear Physics of Academy of Sciences of Uzbekistan Republic. The quality of labeled preparations is very high. The specifications for above mentioned preparations corresponds to demands most of customers in different countries. P-32 or P-33 labeled orthophosphoric acid has high radiochemical purity (more than 99 %) and specific radioactivity close to theoretical. Orthophosphoric acid prepared by the described above method has radiochemical purity about 95 % and output of the target product 99%

  7. Use of stable isotopes method in hydrological investigations with special reference to studies in Lower Maner Basin, Andhra Pradesh

    International Nuclear Information System (INIS)

    Kumar, B.; Athavale, R.N.; Sahay, K.S.N.

    1982-01-01

    The study of variations of stable isotope ratios in water is becoming increasingly important in hydrological investigations and is being widely used for: (i) characterizing water masses and indicating their origin, (ii) finding interconnection of water bodies, (iii) estimating leakages for reservoirs, (iv) water balances studies of lakes, (v) glaciological studies, etc. This paper briefly describes the principle of the method and details of isotope ratio measurement techniques used at the National Geophysical Research Institute, Hyderabad. Integrated geohydrological investigations comprising photogeological, hydrogeochemical, geophysical, nuclear and modelling studies have been carried out in the Lower Maner Basin, A.P., under an Indo-German collaboration project. As a part of this programme,, precipitation, surface and sub-surface water samples from the basin were analysed for their D:H and O 18 :O 16 ratios. The results of these measurements are presented and discussed. (author)

  8. Using 13C isotopes to explore denitrification-dependent anaerobic methane oxidation in a paddy-peatland.

    Science.gov (United States)

    Shi, Yao; Wang, Zhongqiang; He, Chunguang; Zhang, Xinyu; Sheng, Lianxi; Ren, Xiaodong

    2017-01-18

    Peatlands are organic-matter-rich but nitrogen-limited natural systems, the carbon/nitrogen (C/N) status of which are subject to increasing exposure from long-term nitrate (NO 3 - ) fertilizer inputs and atmospheric nitrogen (N) deposits. To manage and protect these unique environments, an improved understanding of denitrification-dependent anaerobic oxidation of methane (DAMO) in peatlands is needed. In this study, we used stable isotope measurements and incubation with NO 3 - additions to facilitate an investigation and comparison of the potential DAMO rates in a paddy-peatland that has been influenced by N fertilizer over 40 years and an undisturbed peatland in northeast China. Monitoring of 13 CO 2 production confimed DAMO did occur in both the paddy-peatland and the undisturbed peatland, the rates of which increased with NO 3 - additions, but decreased logarithmically with time. When NO 3 - was added, there were no significant differences between the CH 4 oxidation in the paddy-peatland and peatland samples after 36 hours of incubation (97.08 vs. 143.69 nmol g -1 dry peat) and the potential DAMO rate after incubation for 1 hour (92.53 vs. 69.99 nmol g -1  h -1 ). These results indicate that the occurrence of DAMO in peatlands might be controlled by the amount of NO 3 - applied and the depth to which it penetrates into the anoxic layer.

  9. EXPLORATION BY MEANS OF GEOPHYSICAL METHODS OF GEOTHERMAL FIELDS AND CASE STUDIES

    Directory of Open Access Journals (Sweden)

    Züheyr KAMACI

    1997-01-01

    Full Text Available Geothermal energy which is one of the reuseable energy resources, can save as much as 77 million barrels of petroleum equivalent annually when used in the production of electricity and heating-environment. Geophysical exploration methods plays in important role in the fields of geothermal exploration, development and observational studies. Thermal and geoelectrical methods are the most effective methods which shows the temperature variation anomalies and mechanical drilling places. But, when the other methods of gravity, magnetic, radiometric, well geophysics and well logs can be used in conjunction with seismic tomography, apart from the mentioned geophysical exploration method, better results could be obtained. From the above mentioned facts various case history reports are given from our country and worldwide to determine geothermal energy resources by using geophysical exploration technique application. From these results of studies a 55 °C hot water artessian aquifer is found in the Uşak-Banaz geothermal field by applying geoelectrical methods.

  10. GEOLOGICAL-GEOPHYSICAL EXPLORATION OF THE BAUXITE DEPOSITS APPLICATION OF THE SHALLOW SEIZMIC REFLECTION METHOD

    OpenAIRE

    Ivan Dragičević; Miroslav Andrić; Ivan Blašković

    1991-01-01

    The exploration of bauxite deposits in the region of the carbonaceous Dinarides has been performed by using different geological and geophysical methods. Deposits laying shallower or deeper below the roof sediments have so far most often been discovered by expensive drilling methods in a corresponding grid. Complex geological explorations have led to a series of valuable data thus enabling the application of other much more economical methods as well. In the region of the bauxite sedimentary ...

  11. Hot vacuum extraction-isotopic dilution mass spectrometry for determination of hydrogen isotopes in zircaloys

    International Nuclear Information System (INIS)

    Shi, Y.; Leeson, P.K.; Wilkin, D.; Britton, A.; Macleod, R.

    2016-01-01

    A hot vacuum extraction-isotope dilution mass spectrometry (HVE-IDMS) was studied for determination of hydrogen isotopes in zirconium metal and alloys as nuclear reactor materials. A theoretical assessment of the completeness of the extraction of hydrogen isotopes under the chosen condition was carried out based on the hydrogen and deuterium solubility data for zirconium. The optimal isotopic spiking condition for conventional IDMS was further explored for the special case IDMS where the isotope abundance of the samples is varied and non-natural. Applying the optimal conditions, the accurate IDMS determination was realized. The agreement between the measured values and the certified or prepared values of standard reference materials and homemade standard materials validate the method developed. (author)

  12. Isotopes in heterogeneous catalysis

    CERN Document Server

    Hargreaves, Justin SJ

    2006-01-01

    The purpose of this book is to review the current, state-of-the-art application of isotopic methods to the field of heterogeneous catalysis. Isotopic studies are arguably the ultimate technique in in situ methods for heterogeneous catalysis. In this review volume, chapters have been contributed by experts in the field and the coverage includes both the application of specific isotopes - Deuterium, Tritium, Carbon-14, Sulfur-35 and Oxygen-18 - as well as isotopic techniques - determination of surface mobility, steady state transient isotope kinetic analysis, and positron emission profiling.

  13. Absorption of food cobalamins assessed by the double isotope method in healthy volunteers and in patients with chronic diarrhoea

    International Nuclear Information System (INIS)

    Kittang, B.; Hamborg, B.; Schjoensby, H.

    1985-01-01

    To make a food preparation containing radioactively labelled cobalamins, rabbits were given repeated injections with 57 Co-labelled cyanocobalamin. The liver was removed, homogenized and fried for one min. or boiled for 30 min. Of the radioactivity in the fried homogenate, 41.7% was recovered in the centrifuged supernatant compared with 50.8% in the boiled homogenate. The radioactivity in the supernatants had a molecular size close to that of free 57 Co-labelled cyanocobalamin. 42% of the radioactivity in the whole homogenate had been incorporated into 5-deoxyadenosyl-, 10% into methyl-and 16.5% into hydroxy-cobalamin. To assess the validity of a double-isotope method for measuring the intestinal absorption of doses of 57 Co-labelled liver cobalamins, 51 CrCl 3 was used as a non-absorbable marker. In 14 healthy volunteers the correlation coefficient between the absorption measured by the double-isotope technique and the faecal excretion test was highly significant (r = 0.96, p 57 Co/ 51 Cr ratio in successive stool collections. In 11 patients with chronic diarrhoea there was a significant correlation between the absorption measured by the double-isotope technique and the faecal excretion test (r = 0.92, p 57 / 51 Cr ratio in successive stool collections

  14. Determination of Light Water Reactor Fuel Burnup with the Isotope Ratio Method

    International Nuclear Information System (INIS)

    Gerlach, David C.; Mitchell, Mark R.; Reid, Bruce D.; Gesh, Christopher J.; Hurley, David E.

    2007-01-01

    For the current project to demonstrate that isotope ratio measurements can be extended to zirconium alloys used in LWR fuel assemblies we report new analyses on irradiated samples obtained from a reactor. Zirconium alloys are used for structural elements of fuel assemblies and for the fuel element cladding. This report covers new measurements done on irradiated and unirradiated zirconium alloys, Unirradiated zircaloy samples serve as reference samples and indicate starting values or natural values for the Ti isotope ratio measured. New measurements of irradiated samples include results for 3 samples provided by AREVA. New results indicate: 1. Titanium isotope ratios were measured again in unirradiated samples to obtain reference or starting values at the same time irradiated samples were analyzed. In particular, 49Ti/48Ti ratios were indistinguishably close to values determined several months earlier and to expected natural values. 2. 49Ti/48Ti ratios were measured in 3 irradiated samples thus far, and demonstrate marked departures from natural or initial ratios, well beyond analytical uncertainty, and the ratios vary with reported fluence values. The irradiated samples appear to have significant surface contamination or radiation damage which required more time for SIMS analyses. 3. Other activated impurity elements still limit the sample size for SIMS analysis of irradiated samples. The sub-samples chosen for SIMS analysis, although smaller than optimal, were still analyzed successfully without violating the conditions of the applicable Radiological Work Permit

  15. Research on the groundwater flow dynamics of Lamas basin by isotope methods

    International Nuclear Information System (INIS)

    Onhon, E.; Sayin, M.; Basaran, N.; Can, D.; Yuce, G.; Pelen, N.; Kaplan, A.

    1996-01-01

    The main objective of Lamas Project is to define the relation between the recharge to highlands and the discharge realized by the springs along the Mediterranean coast and thus assist to the development of karst water resources by preparing a dependable evaluation of the water budget. The investigation area covers almost 4400 square kilometers where the elevation rises from 0 to 2900 m. Lamas is the main river crossing the area from northwest to southeast with a yield between 13.48 to 2.77 cu.m/s. the karstification in the area has at least reached 300 m in depth. The water samples were collected from 16 springs, 3 drilled wells, stream and two meteorological stations, to define the groundwater dynamics and investigate the relation between the sampling points and to assist the establishment of an evaluation in isotope hydrology. By taking into consideration the unmeasured discharges along the coast line, the infiltration from the precipitation is approximately 50-60 %. The water in the aquifer is isotopically affected by the infiltration of low altitude precipitation. The hydrogeological and isotope hydrology investigations have reached the conclusions that the karst water resources can be developed by drilling of deep wells near the karst springs. (author). 9 refs, 7 figs, 2 tabs

  16. Three-stage method for interpretation of uranium-lead isotopic data

    International Nuclear Information System (INIS)

    Nejmark, L.A.; Ovchinnikova, G.V.; Levchenkov, O.A.

    1982-01-01

    Three-dimensional approach for the iterpretation of uranium-lead isoto e ratios in pnatural systems, development of which corresponds to three stages, has been considered. In the framework of the three-stage model two cases, differing in the character of uranium-lead systems violation at the beginning of the third stage, are discussed. The first case corresponds to uranium addition or lead substraction, and the second one - to addition of lead of unknown isotopic content. Three-stage approach permits without amending the isotopic content of lead captured during crystallization to calculated the beginning of the second and third stages of uranium-lead systems development and to evaluate parameters of lead added to the system. Concrete examples of interpretation of uranium-lead isotopic ratios in minerals and rock samples as a whole both of the terrestrial and cosmic origin are considered. Possibilities and limitations of the three-stage approach are analyzed and directions of further development are outlined

  17. Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

    Science.gov (United States)

    Melanson, Edward L; Swibas, Tracy; Kohrt, Wendy M; Catenacci, Vicki A; Creasy, Seth A; Plasqui, Guy; Wouters, Loek; Speakman, John R; Berman, Elena S F

    2018-02-01

    When the doubly labeled water (DLW) method is used to measure total daily energy expenditure (TDEE), isotope measurements are typically performed using isotope ratio mass spectrometry (IRMS). New technologies, such as off-axis integrated cavity output spectroscopy (OA-ICOS) provide comparable isotopic measurements of standard waters and human urine samples, but the accuracy of carbon dioxide production (V̇co 2 ) determined with OA-ICOS has not been demonstrated. We compared simultaneous measurement V̇co 2 obtained using whole-room indirect calorimetry (IC) with DLW-based measurements from IRMS and OA-ICOS. Seventeen subjects (10 female; 22 to 63 yr) were studied for 7 consecutive days in the IC. Subjects consumed a dose of 0.25 g H 2 18 O (98% APE) and 0.14 g 2 H 2 O (99.8% APE) per kilogram of total body water, and urine samples were obtained on days 1 and 8 to measure average daily V̇co 2 using OA-ICOS and IRMS. V̇co 2 was calculated using both the plateau and intercept methods. There were no differences in V̇co 2 measured by OA-ICOS or IRMS compared with IC when the plateau method was used. When the intercept method was used, V̇co 2 using OA-ICOS did not differ from IC, but V̇co 2 measured using IRMS was significantly lower than IC. Accuracy (~1-5%), precision (~8%), intraclass correlation coefficients ( R = 0.87-90), and root mean squared error (30-40 liters/day) of V̇co 2 measured by OA-ICOS and IRMS were similar. Both OA-ICOS and IRMS produced measurements of V̇co 2 with comparable accuracy and precision compared with IC.

  18. Effects of preservation methods of muscle tissue from upper-trophic level reef fishes on stable isotope values (δ (13)C and δ (15)N).

    Science.gov (United States)

    Stallings, Christopher D; Nelson, James A; Rozar, Katherine L; Adams, Charles S; Wall, Kara R; Switzer, Theodore S; Winner, Brent L; Hollander, David J

    2015-01-01

    Research that uses stable isotope analysis often involves a delay between sample collection in the field and laboratory processing, therefore requiring preservation to prevent or reduce tissue degradation and associated isotopic compositions. Although there is a growing literature describing the effects of various preservation techniques, the results are often contextual, unpredictable and vary among taxa, suggesting the need to treat each species individually. We conducted a controlled experiment to test the effects of four preservation methods of muscle tissue from four species of upper trophic-level reef fish collected from the eastern Gulf of Mexico (Red Grouper Epinephelus morio, Gag Mycteroperca microlepis, Scamp Mycteroperca phenax, and Red Snapper Lutjanus campechanus). We used a paired design to measure the effects on isotopic values for carbon and nitrogen after storage using ice, 95% ethanol, and sodium chloride (table salt), against that in a liquid nitrogen control. Mean offsets for both δ (13)C and δ (15)N values from controls were lowest for samples preserved on ice, intermediate for those preserved with salt, and highest with ethanol. Within species, both salt and ethanol significantly enriched the δ (15)N values in nearly all comparisons. Ethanol also had strong effects on the δ (13)C values in all three groupers. Conversely, for samples preserved on ice, we did not detect a significant offset in either isotopic ratio for any of the focal species. Previous studies have addressed preservation-induced offsets in isotope values using a mass balance correction that accounts for changes in the isotope value to that in the C/N ratio. We tested the application of standard mass balance corrections for isotope values that were significantly affected by the preservation methods and found generally poor agreement between corrected and control values. The poor performance by the correction may have been due to preferential loss of lighter isotopes and

  19. Capture and isotopic exchange method for water and hydrogen isotopes on zeolite catalysts up to technical scale for pre-study of processing highly tritiated water

    Energy Technology Data Exchange (ETDEWEB)

    Michling, R.; Braun, A.; Cristescu, I.; Dittrich, H.; Gramlich, N.; Lohr, N. [Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen (Germany); Glugla, M.; Shu, W.; Willms, S. [ITER Organization, Saint-Paul-lez-Durance (France)

    2015-03-15

    Highly tritiated water (HTW) may be generated at ITER by various processes and, due to the excessive radio toxicity, the self-radiolysis and the exceedingly corrosive property of HTW, a potential hazard is associated with its storage and process. Therefore, the capture and exchange method for HTW utilizing Molecular Sieve Beds (MSB) was investigated in view of adsorption capacity, isotopic exchange performance and process parameters. For the MSB, different types of zeolite were selected. All zeolite materials were additionally coated with platinum. The following work comprised the selection of the most efficient zeolite candidate based on detailed parametric studies during the H{sub 2}/D{sub 2}O laboratory scale exchange experiments (about 25 g zeolite per bed) at the Tritium Laboratory Karlsruhe (TLK). For the zeolite, characterization analytical techniques such as Infrared Spectroscopy, Thermogravimetry and online mass spectrometry were implemented. Followed by further investigation of the selected zeolite catalyst under full technical operation, a MSB (about 22 kg zeolite) was processed with hydrogen flow rates up to 60 mol*h{sup -1} and deuterated water loads up to 1.6 kg in view of later ITER processing of arising HTW. (authors)

  20. Accuracy of some routine method used in clinical chemistry as judged by isotope dilution-mass spectrometry

    International Nuclear Information System (INIS)

    Bjoerkhem, I.; Bergman, A.; Falk, O.; Kallner, A.; Lantto, O.; Svensson, L.; Akerloef, E.; Blomstrand, R.

    1981-01-01

    Serum from patients was pooled, filtered, dispensed, and frozen. This pooled specimen was used for accuracy control in 64 participating laboratories in Sweden. Mean values (state-of-the-art values) were obtained for creatinine, cholesterol, glucose, urea, uric acid, and cortisol. These values were compared with values obtained with highly accurate reference methods based on isotope dilution-mass spectrometry. Differences were marked in the case of determination of creatinine and cortisol. Concerning the other components, the differences between the state-of-the-art value and the values obtained with the reference methods were negligible. Moreover, the glucose oxidase and the oxime methods for determination of glucose and urea were found to give significantly lower values than the hexokinase and urease methods, respectively. Researchers conclude that methods with a higher degree of accuracy are required for routine determination of creatinine and cortisol

  1. Laser separation of uranium isotopes

    International Nuclear Information System (INIS)

    Porter, J.T.

    1981-01-01

    Method and apparatus for separating uranium isotopes are claimed. The method comprises the steps of irradiating a uranyl source material at a wavelength selective to a desired isotope and at an effective temperature for isotope spectral line splitting below about 77 deg.K., further irradiating the source material within the fluorescent lifetime of the source material to selectively photochemically reduce the excited isotopic species, and chemically separating the reduced isotope species from the remaining uranyl salt compound

  2. Superdeformation in Pb isotopes

    International Nuclear Information System (INIS)

    Naz, Tabassum; Ahmad, Shakeb

    2017-01-01

    The Relatvistic Hartree-Bogoliubov (RHB) theory is used to explore the structure of superdeformed (SD) 190,212 Pb isotopes using the non-linear NL3* and density dependent (DD-ME2, DD-PC1) interactions. We have studied the the excitation energy, the potential depth and the deformation of these Pb isotopes

  3. Experimental design-based isotope-dilution SPME-GC/MS method development for the analysis of smoke flavouring products.

    Science.gov (United States)

    Giri, Anupam; Zelinkova, Zuzana; Wenzl, Thomas

    2017-12-01

    For the implementation of Regulation (EC) No 2065/2003 related to smoke flavourings used or intended for use in or on foods a method based on solid-phase micro extraction (SPME) GC/MS was developed for the characterisation of liquid smoke products. A statistically based experimental design (DoE) was used for method optimisation. The best general conditions to quantitatively analyse the liquid smoke compounds were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 60°C extraction temperature, 30 min extraction time, 250°C desorption temperature, 180 s desorption time, 15 s agitation time, and 250 rpm agitation speed. Under the optimised conditions, 119 wood pyrolysis products including furan/pyran derivatives, phenols, guaiacol, syringol, benzenediol, and their derivatives, cyclic ketones, and several other heterocyclic compounds were identified. The proposed method was repeatable (RSD% <5) and the calibration functions were linear for all compounds under study. Nine isotopically labelled internal standards were used for improving quantification of analytes by compensating matrix effects that might affect headspace equilibrium and extractability of compounds. The optimised isotope dilution SPME-GC/MS based analytical method proved to be fit for purpose, allowing the rapid identification and quantification of volatile compounds in liquid smoke flavourings.

  4. Fundamental and clinical studies on simultaneous, quantitative analysis of hepatobiliary and gastrointestinal scintigrams using double isotope method

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, Y; Kakihara, M; Sasaki, M; Tabuse, Y; Takei, N [Wakayama Medical Coll. (Japan)

    1981-04-01

    Double isotope method was applied to carry out simultaneous and quantitative analysis of hepatobiliary and gastrointestinal scintigrams. A scinticamera with parallel collimator for medium energy was connected to a computer to distinguish the two isotopes at a time. 4mCi of sup(99m)Tc-(Sn)-pyridoxylideneisoleucine (Tc-PI) and 200 ..mu..Ci of /sup 111/In-diethylenetriaminepentaacetic acid (In-DTPA) were administrated by i.v. injection and per oral, respectively. Three normal (two women and a man) and 16 patients after the operation of gastric cancer (10 recovered by Roux-en Y method after the total gastrectomy, and 6 recovered after the operation replacing the jejunum between the esophagus and duodenum) were investigated. The process of bile secretion and its mixing with food were followed by the scanning quantitatively. The analysis of time-activity variation at each organ indicated that the replacing operation gave more physiological recovery than that by Roux-en Y method. This method is noninvasive to patients and is promising to follow the process or activity of digestion in any digestive organ after surgery.

  5. Formic acid hydrolysis/liquid chromatography isotope dilution mass spectrometry: An accurate method for large DNA quantification.

    Science.gov (United States)

    Shibayama, Sachie; Fujii, Shin-Ichiro; Inagaki, Kazumi; Yamazaki, Taichi; Takatsu, Akiko

    2016-10-14

    Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) with formic acid hydrolysis was established for the accurate quantification of λDNA. The over-decomposition of nucleobases in formic acid hydrolysis was restricted by optimizing the reaction temperature and the reaction time, and accurately corrected by using deoxynucleotides (dNMPs) and isotope-labeled dNMPs as the calibrator and the internal standard, respectively. The present method could quantify λDNA with an expanded uncertainty of 4.6% using 10fmol of λDNA. The analytical results obtained with the present method were validated by comparing with the results of phosphate-base quantification by inductively coupled plasma-mass spectrometry (ICP-MS). The results showed good agreement with each other. We conclude that the formic acid hydrolysis/LC-IDMS method can quantify λDNA accurately and is promising as the primary method for the certification of DNA as reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Atomic and molecular isotope separation

    International Nuclear Information System (INIS)

    Melamed, N.T.

    1979-01-01

    A method for differentially exciting a selected isotopic species in a mixture of isotopic species is described characterized in that almost the entire isotopic mixture is placed in an excited gaseous state; and a preselected isotopic species is then selectively de-excited through stimulated emission

  7. A mixed-methods study exploring student nurses’ understanding of futile CPR

    OpenAIRE

    Batty, Emma

    2014-01-01

    Abstract Background: Futile CPR has the potential to inflict significant, avoidable harms on dying patients. Futile CPR is widely debated in the literature, but there is little research into futile CPR in the context of nursing. There are no published studies exploring student nurses’ understanding of futile CPR. Aim: To explore student nurses’ understanding of futile CPR Methods: A mixed methods study, using questionnaires to establish background data and identify prominent issues. ...

  8. The study on effect of zeolite on nitrogen use efficiency of corn by 15N-isotope dilution method

    International Nuclear Information System (INIS)

    Li Changhong; Li Huaxing; Zhang Xinming; Liu Yuanjin

    2002-01-01

    A pot experiment was carried out to study the effect of natural zeolite on nitrogen use efficiency of corn by using 15 N-isotope dilution method. The results showed that application of zeolite could improve the corn growth and enhance the biomass of the corn seedling. By using zeolite, nitrogen use efficiency (NUE) of corn was increased by 23.2%-33.1% as compared with no-zeolite treatment; and the residual nitrogen has no significant difference between zeolite treatment and no-zeolite treatment

  9. A rapid method for α-spectrometric analysis of radium isotopes in natural waters using ion-selective membrane technology

    International Nuclear Information System (INIS)

    Purkl, Stefan; Eisenhauer, Anton

    2003-01-01

    An α-spectrometric method for the rapid determination of radium isotopes ( 223 Ra, 224 Ra and 226 Ra) in environmental samples is presented. Using Empore TM Radium Rad Disks complete separation of the target radionuclides is achieved. The high selectivity of these Rad Disks allows the straightforward use of 225 Ra as yield tracer. Chemical yield is up to 92±9%. The chemical procedure can be accomplished within 5 h. α-Sources show energy resolution in the range of typically 26-40 keV (FWHM). Despite minimal thickness of the sources no significant radon (Rn) losses can be observed

  10. Mass spectrometric methods for studying nutrient mineral and trace element absorption and metabolism in humans using stable isotopes: a review

    International Nuclear Information System (INIS)

    Crews, H.M.; Eagles, J.; Mellon, F.A.; Luten, J.B.; McGaw, B.A.

    1994-01-01

    Mass spectrometric methods for determining stable isotopes of nutrient minerals and trace elements in human metabolic studies are described and discussed. The advantages and disadvantages of the techniques of electron ionization, fast atom bombardment, thermal ionization, and inductively coupled plasma and gas chromatography mass spectrometry are evaluated with reference to their accuracy, precision, sensitivity, and convenience, and the demands of human nutrition research. Examples of specific applications are described and the significance of current developments in mass spectrometry are discussed with reference to present and probable future research needs. (Author)

  11. New NMR method for measuring the difference between corresponding proton and deuterium chemical shifts: isotope effects on exchange equilibria

    International Nuclear Information System (INIS)

    Saunders, M.; Saunders, S.; Johnson, C.A.

    1984-01-01

    A convenient and accurate method is described for measuring the difference between a proton frequency and the corresponding deuterium frequency in its deuterated analogue relative to a reference system by using the deuterium lock in a Fourier-transform NMR spectrometer. This measurement is a sensitive way of measuring equilibrium isotope effects for hydrogen-deuterium exchange. A value of 1.60 per H-D pair is obtained for the equilibrium 2H 3 O + + 3D 2 O in equilibrium 2D 3 O + + 3H 2 O at 30 0 C in aqueous perchloric acid (HClO 4 ). 7 references, 2 tables

  12. Lifetimes in neutron-rich Nd isotopes measured by Doppler profile method

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Lister, C.J.; Morss, L.R. [and others

    1995-08-01

    Lifetimes of the rotational levels in neutron-rich even-even Nd isotopes were deduced from the analysis of the Doppler broadened line shapes. The experiment was performed at Daresbury with the Eurogam array, which at that time consisted of 45 Compton-suppressed Ge detectors and 5 Low-Energy Photon Spectrometers. The source was in the form of a 7-mm pellet which was prepared by mixing 5-mg; {sup 248}Cm and 65-mg KCl and pressing it under high pressure. Events for which three or more detectors fired were used to construct a cubic data array whose axes represented the {gamma}-ray energies and the contents of each channel the number of events with that particular combination of {gamma}-ray energies. From this cubic array, one-dimensional spectra were generated by placing gates on peaks on the other two axes. Gamma-ray spectra of even-even Nd isotopes were obtained by gating on the transitions in the complimentary Kr fragments. The gamma peaks de-exciting states with I {>=} 12 h were found to be broader than the instrumental line width due to the Doppler effect. The line shapes of they-ray peaks were fitted separately with a simple model for the feeding of the states and assuming a rotational band with constant intrinsic quadruple moment and these are shown in Fig. I-27. The quadrupole moments thus determined were found to be in good agreement with the quadrupole moments measured previously for lower spin states. Because of the success of this technique for the Nd isotopes, we intend to apply this technique to the new larger data set collected with the Eurogam II array. The results of this study were published.

  13. Stable isotope phenotyping via cluster analysis of NanoSIMS data as a method for characterizing distinct microbial ecophysiologies and sulfur-cycling in the environment

    Directory of Open Access Journals (Sweden)

    Katherine S Dawson

    2016-05-01

    Full Text Available Stable isotope probing (SIP is a valuable tool for gaining insights into ecophysiology and biogeochemical cycling of environmental microbial communities by tracking isotopically labeled compounds into cellular macromolecules as well as into byproducts of respiration. SIP, in conjunction with nanoscale secondary ion mass spectrometry (NanoSIMS, allows for the visualization of isotope incorporation at the single cell level. In this manner, both active cells within a diverse population as well as heterogeneity in metabolism within a homogeneous population can be observed. The ecophysiological implications of these single cell stable isotope measurements are often limited to the taxonomic resolution of paired fluorescence in situ hybridization (FISH microscopy. Here we introduce a taxonomy-independent method using multi-isotope SIP and NanoSIMS for identifying and grouping phenotypically similar microbial cells by their chemical and isotopic fingerprint. This method was applied to SIP experiments in a sulfur-cycling biofilm collected from sulfidic intertidal vents amended with 13C-acetate, 15N-ammonium, and 33S-sulfate. Using a cluster analysis technique based on fuzzy c-means to group cells according to their isotope (13C/12C, 15N/14N, and 33S/32S and elemental ratio (C/CN and S/CN profiles, our analysis partitioned ~2200 cellular regions of interest (ROIs into 5 distinct groups. These isotope phenotype groupings are reflective of the variation in labeled substrate uptake by cells in a multispecies metabolic network dominated by Gamma- and Deltaproteobacteria. Populations independently grouped by isotope phenotype were subsequently compared with paired FISH data, demonstrating a single coherent deltaproteobacterial cluster and multiple gammaproteobacterial groups, highlighting the distinct ecophysiologies of spatially-associated microbes within the sulfur-cycling biofilm from White Point Beach, CA.

  14. Novel Stable Isotope Methods for Assessing Changes in Seasonality of Precipitation from Sediments of Ombrotrophic Peatlands

    Science.gov (United States)

    Nichols, J. E.; Booth, R. K.; Jackson, S. T.; Pendall, E. G.; Walcott, M.; Bradley, R.; Pilcher, J.; Huang, Y.

    2007-12-01

    The seasonality of precipitation is a key but often elusive climate parameter in paleoclimate reconstructions. Sediments from ombrotrophic peatlands are excellent archives of past changes in precipitation/evaporation balance. Here we show that these peatland sediments can also be used to assess changes in the seasonality of precipitation. We have recently determined that distributions of Sphagnum and vascular plant biomarkers sensitively record changes in hydrologic balance (Nichols et al., 2006, Org. Geochem. 37, 1505-1513), but biomarker distributions alone do not offer detailed information for the changes in seasonal precipitation. In this study, we combine biomarker and compound-specific H and C isotope ratios to create a more comprehensive picture of the changing climate affecting these sensitive ombrotrophic systems. We present here two sets of downcore data from sites in Arctic Europe as well as Eastern North America. Basic paleohydrology is established using a ratio of Sphagnum to vascular plant biomarkers (C23 and C29 n-alkanes, respectively. We further describe paleohydrology using novel stable isotope proxies based on δD and δ13C measurements of Sphagnum and vascular plant biomarkers. Because Sphagnum has no vascular system and loses water directly by evaporation, Sphagnum biomarkers enriched in deuterium indicate an evaporative growing season (summer). Vascular plants use their root systems to take up water stored within the peatland, so deuterium-depleted vascular plant biomarkers should indicate increased winter recharge of the peatland. A methanotrophic symbiont living inside the Sphagnum's hyaline (water-holding) cells is more active when the Sphagnum is wet and therefore provides more 13C depleted (methane- derived) carbon dioxide for biomass production when the growing season is less evaporative. Hence, 13C depleted Sphagnum biomarkers indicate increased methanotrophy and therefore a wetter summer. We corroborate our stable isotope proxies by

  15. Geochemistry of silicon isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Tiping; Li, Yanhe; Gao, Jianfei; Hu, Bin [Chinese Academy of Geological Science, Beijing (China). Inst. of Mineral Resources; Jiang, Shaoyong [China Univ. of Geosciences, Wuhan (China).

    2018-04-01

    Silicon is one of the most abundant elements in the Earth and silicon isotope geochemistry is important in identifying the silicon source for various geological bodies and in studying the behavior of silicon in different geological processes. This book starts with an introduction on the development of silicon isotope geochemistry. Various analytical methods are described and compared with each other in detail. The mechanisms of silicon isotope fractionation are discussed, and silicon isotope distributions in various extraterrestrial and terrestrial reservoirs are updated. Besides, the applications of silicon isotopes in several important fields are presented.

  16. Applications of stable isotopes

    International Nuclear Information System (INIS)

    Letolle, R.; Mariotti, A.; Bariac, T.

    1991-06-01

    This report reviews the historical background and the properties of stable isotopes, the methods used for their measurement (mass spectrometry and others), the present technics for isotope enrichment and separation, and at last the various present and foreseeable application (in nuclear energy, physical and chemical research, materials industry and research; tracing in industrial, medical and agronomical tests; the use of natural isotope variations for environmental studies, agronomy, natural resources appraising: water, minerals, energy). Some new possibilities in the use of stable isotope are offered. A last chapter gives the present state and forecast development of stable isotope uses in France and Europe

  17. A comparison between isotopic and different methods for determining urea fertilizer use efficiency under trickle figuration on tomato

    International Nuclear Information System (INIS)

    Mousavi Shalmani, M.A.; Sagheb, N.; Rafii, H.; Hobbi, M.S.; Khorosani, A.

    2002-01-01

    In order to study the fertilizer use efficiency by two different methods, an experimental design was conducted in Randomized Complete Block (RBC) with four replications and treatments in the plots with 35 square meter, area. 1200 seedlings of tomato (variety of early Urbana V.F.) were planted on June 3. 1996 at the distances of 50 cm apart. Fertilization and irrigation were performed by two fertilizer pumps (one for P and K and the other for N). The treatments of N 0 , N 1 , N 2 and N 3 received 0, 287.5, 575 and 862.5 kg N/ha respectively. The 14 N/ 15 N isotopic ratio of nitrogen gas was determined by the use of emission spectrometer and the fertilizer use efficiency was determined by using nuclear chemical equations. Because of the shortage of micro nutrients in soil and unbalanced quantity of N,P and K as fertilizers the results have shown a large amount of free radicals (NH 4 , NO 3 ) remained in the soil. This disturbed the balance between absorption of nitrogen from its different sources in the soil. Therefor, the share of fertilizer increased and in this condition, the priming effects were seen and different methods showed lower amounts of fertilizer use efficiency in comparison with the isotopic method

  18. A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123

    International Nuclear Information System (INIS)

    Tsuji, Akinori; Kojima, Akihiro; Oyama, Yoichi; Tomiguchi, Seiji; Kira, Tomohiro; Takagi, Yoshikazu; Shimomura, Osamu; Takahashi, Mutsumasa; Matsumoto, Masanori

    1999-01-01

    We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a Tl-201 line source and an I-123 line source were obtained to measure line spread functions (LSFs) and crosstalk ratios for each image. The line source experiments showed that the LSFs for the Tl-201 imaging window from the single Tl-201 source were very similar to those for the I-123 imaging window from the single Tl-201 source, but the LSFs for the Tl-201 imaging window from the single I-123 source had broad shapes which differed from those for the I-123 imaging window from the single I-123. To obtain accurate I-123 crosstalk images in the Tl-201 imaging window from the I-123 images in the I-123 imaging window, we designed a low-pass blurring filter. In 7 clinical I-123 MIBG studies, I-123 window images processed with this filter became very similar to the Tl-201 window image from the single I-123 source. The method proposed in this study can accurately correct the crosstalk in dual isotope studies with Tl-201 and I-123 and is easily applicable to conventional gamma camera systems with any dual energy window acquisition mode. (author)

  19. GEOLOGICAL-GEOPHYSICAL EXPLORATION OF THE BAUXITE DEPOSITS APPLICATION OF THE SHALLOW SEIZMIC REFLECTION METHOD

    Directory of Open Access Journals (Sweden)

    Ivan Dragičević

    1991-12-01

    Full Text Available The exploration of bauxite deposits in the region of the carbonaceous Dinarides has been performed by using different geological and geophysical methods. Deposits laying shallower or deeper below the roof sediments have so far most often been discovered by expensive drilling methods in a corresponding grid. Complex geological explorations have led to a series of valuable data thus enabling the application of other much more economical methods as well. In the region of the bauxite sedimentary basin Mesihovina-Rakitno, western Herzegovina, at the site of Studena vrila - after extensive geological explorations - a conclusion was drawn that the shallow seismic reflection geophysical method as well might be successfully applied in locating new bauxite deposits. In the paper, the geological framework of the bauxite deposits occurrences, stipulating the selection of this methode, will be presented. Measurements were performed on a known deposit (L-84, Povaljenica, completely defined by exploration drilling. The obtained results justify the selection of the shallow seismic reflection method as one of the methods for exploring bauxite deposits beneath the roof beds.

  20. Temperature measurements of Transdanubian Mesozoic rocks by the oxygen isotope method

    International Nuclear Information System (INIS)

    Cornides, I.; Csaszar, G.; Haas, J.; Jochane Edelenyi, E.

    1979-01-01

    Subjected to paleotemperature measurements with the use of oxygen and carbon isotopes were Upper Triassic, Jurassic and Cretaceous sedimentary rocks and their fossils from the Transdanubian Central Mountains, the Mecsek and the Villany Mts. In determining formation temperature, an important parameter of the environment of formation, the authors relied on the fact that the oxygen isotope composition of calcium carbonate precipitating from its aqueous solution deviates, in dependence on the temperature of the solution concerned, from that of the water. Consequently, the temperature of the water of the one-time seas must have been recorded by the 18 O/ 16 O ratio in the calcite of fossils or sediments. The results reported indicate smaller changes in temperature as compared to international results. In the Jurassic the values of temperature remain consistently below those quoted for Swiss and French territories, being around the values reported from/sroe/thern Germany. These u curves have their maxima in the Toarcian, Aalenian, sediments for which unfortunately no Hungarian results are available. The few results of Cretaceous belemnites are values higher than their international counterparts. The high temperature value obtained for the Albian correlates very well with the formation of rocks known from this stratigraphic stage (red clays, bauxites). (A.L.)

  1. A new method of accurate determination of isotopic composition and concentration of strontium in a spike solution used for geochronological works

    International Nuclear Information System (INIS)

    Yanagi, Takeru

    1990-01-01

    A new method of accurate determination of isotopic composition and concentration of a strontium-84 spike solution was devised for simultaneous determination of strontium contents and isotopic compositions in rocks and minerals by measuring strontium isotopic ratios in spiked samples. In this method, the isotopic composition of strontium in the spike were determined so as to minimize the sum of squares of deviations of spike strontium-84 concentrations which were calculated from measured isotopic ratios of strontium in five different mixtures of the spike and the standard solution. The method can eliminate all mass discriminations occurred during the measurements on a surface ionization mass spectrometer. The results were tested by measuring 87 Sr/ 86 Sr ratios of Eimer and Amend SrCO 3 and JB-1 geochemical reference material, and by determining the strontium content in JB-1. The measurements of strontium isotope ratios in spiked samples give average values of 0.708007±0.000052 and 0.70417±0.00004 for 87 Sr/ 86 Sr ratios of E and A SrCO 3 and JB-1, respectively. The strontium content in JB-1 was estimated at 457.1±1.3 ppm. These values are very close to reported respective values. (author)

  2. Detecting isotopic ratio outliers

    International Nuclear Information System (INIS)

    Bayne, C.K.; Smith, D.H.

    1985-01-01

    An alternative method is proposed for improving isotopic ratio estimates. This method mathematically models pulse-count data and uses iterative reweighted Poisson regression to estimate model parameters to calculate the isotopic ratios. This computer-oriented approach provides theoretically better methods than conventional techniques to establish error limits and to identify outliers. 6 refs., 3 figs., 3 tabs

  3. Detecting isotopic ratio outliers

    Science.gov (United States)

    Bayne, C. K.; Smith, D. H.

    An alternative method is proposed for improving isotopic ratio estimates. This method mathematically models pulse-count data and uses iterative reweighted Poisson regression to estimate model parameters to calculate the isotopic ratios. This computer-oriented approach provides theoretically better methods than conventional techniques to establish error limits and to identify outliers.

  4. Detecting isotopic ratio outliers

    International Nuclear Information System (INIS)

    Bayne, C.K.; Smith, D.H.

    1986-01-01

    An alternative method is proposed for improving isotopic ratio estimates. This method mathematically models pulse-count data and uses iterative reweighted Poisson regression to estimate model parameters to calculate the isotopic ratios. This computer-oriented approach provides theoretically better methods than conventional techniques to establish error limits and to identify outliers

  5. Application of in situ current normalized PIGE method for determination of total boron and its isotopic composition

    International Nuclear Information System (INIS)

    Chhillar, Sumit; Acharya, R.; Sodaye, S.; Pujari, P.K.

    2014-01-01

    A particle induced gamma-ray emission (PIGE) method using proton beam has been standardized for determination of isotopic composition of natural boron and enriched boron samples. Target pellets of boron standard and samples were prepared in cellulose matrix. The prompt gamma rays of 429 keV, 718 keV and 2125 keV were measured from 10 B(p,αγ) 7 Be, 10 B(p, p'γ) 10 B and 11 B(p, p'γ) 11 B nuclear reactions, respectively. For normalizing the beam current variations in situ current normalization method was used. Validation of method was carried out using synthetic samples of boron carbide, borax, borazine and lithium metaborate in cellulose matrix. (author)

  6. APPLICATION OF O-H-B-Sr ISOTOPE SYSTEMATICS TO THE EXPLORATION OF SALINIZATION AND FLUSHING IN COASTAL AQUIFERS : PRELIMINARY DATA FROM THE PIALASSA BAIONA ECOSYSTEM (ADRIATIC SEA

    Directory of Open Access Journals (Sweden)

    Riccardo Petrini

    2009-07-01

    Full Text Available O, H, B and Sr isotopes were identified from surface-waters, ground-waters and waters percolating in soils at the Pialassa Baiona lagoon and nearby inland areas. The preliminary data demonstrate the occurrence of both conservative mixtures between seawater and freshwaters and cation exchange at the salt/fresh water interface during the intrusion. The O and H isotopes indicate that the freshwater component in the binary mixing had the isotopic features of the rainwater from Apennine catchments. Coupled O-H-B isotopes also show that the major contribution of the moving seawater was confined to the deeper aquifers and some of the soil waters. The Sr isotopes highlight the role of cation exchanges when seawater flushes freshwater aquifers, and allow the recognition of the different components of the solute. Deviations from these processes as revealed by B isotopes are interpreted as the evidence of possible anthropogenic inputs.

  7. ASE extraction method for simultaneous carbon and nitrogen stable isotope analysis in soft tissues of aquatic organisms

    International Nuclear Information System (INIS)

    Bodin, Nathalie; Budzinski, Helene; Le Menach, Karyn; Tapie, Nathalie

    2009-01-01

    Since lipids are depleted in 13 C relative to proteins and carbohydrates, variations in lipid composition among species and within individuals significantly influence δ 13 C and may result in misleading ecological interpretations. Whereas lipid extraction before IRMS analysis constitutes a way of stable isotope result lipid-normalisation, such a procedure was given up because of the un-controlled effects of the methods used (i.e., 'Bligh and Dyer', Soxhlet, etc.) on δ 15 N. The aim of this work was to develop a simple, rapid and efficient lipid extraction method allowing for simultaneous C and N stable isotope analysis in the biological soft tissues of aquatic organisms. The goal was to be free from the lipid influence on δ 13 C values without interfering with δ 15 N values. For that purpose, the modern automated pressurized liquid extraction technique ASE (accelerated solvent extraction) was selected. Eel muscles representative of a broad range of fat contents were extracted via ASE by using different semi-polar solvents (100% dichloromethane and 80% n-hexane/20% acetone) and by operating at different temperature (ambient temperature and 100 deg. C) and pressure (750 and 1900 psi) conditions. The results were discussed in terms of lipid extraction efficiency as well as δ 13 C and δ 15 N variability.

  8. Mass spectrometric method for the determination of the stable isotopic content of nitrous oxide by the technique of direct injection

    International Nuclear Information System (INIS)

    Rahn, T.; Wahlen, M.

    2002-01-01

    A method for the direct isotopic analysis of N 2 O has been developed for VG-Prism H dynamic dual inlet stable isotope mass spectrometer. Tests have shown extreme sensitivity to contamination by carbon dioxide with a dependence of 6.8 per mille per % CO 2 for δ 15 N and 12.4 per mille per % CO 2 for δ 18 O. Trace amounts of CO 2 have proven difficult to eliminate, particularly for small sample sizes. In order to ensure accurate analyses an indicator of CO 2 contamination must be monitored and corrections applied when necessary. We have found that ions with mass to charge ratios of 12 and 22 are excellent proxies for CO 2 contamination. Empirical relationships between these indicator species and CO 2 contamination are documented which allow for corrections to be applied to raw data. Additional corrections required due to the presence of isobaric molecules containing 17 O are described. Issues of standardization are discussed and sample handling procedures described. Finally, these methods and corrections are applied to a suite of stratospheric air samples. (author)

  9. Statistical methods for improving verification of claims of origin for Italian wines based on stable isotope ratios

    International Nuclear Information System (INIS)

    Dordevic, N.; Wehrens, R.; Postma, G.J.; Buydens, L.M.C.; Camin, F.

    2012-01-01

    Highlights: ► The assessment of claims of origin is of enormous economic importance for DOC and DOCG wines. ► The official method is based on univariate statistical tests of H, C and O isotopic ratios. ► We consider 5220 Italian wine samples collected in the period 2000–2010. ► Multivariate statistical analysis leads to much better specificity and easier detection of false claims of origin. ► In the case of multi-modal data, mixture modelling provides additional improvements. - Abstract: Wine derives its economic value to a large extent from geographical origin, which has a significant impact on the quality of the wine. According to the food legislation, wines can be without geographical origin (table wine) and wines with origin. Wines with origin must have characteristics which are essential due to its region of production and must be produced, processed and prepared, exclusively within that region. The development of fast and reliable analytical methods for the assessment of claims of origin is very important. The current official method is based on the measurement of stable isotope ratios of water and alcohol in wine, which are influenced by climatic factors. The results in this paper are based on 5220 Italian wine samples collected in the period 2000–2010. We evaluate the univariate approach underlying the official method to assess claims of origin and propose several new methods to get better geographical discrimination between samples. It is shown that multivariate methods are superior to univariate approaches in that they show increased sensitivity and specificity. In cases where data are non-normally distributed, an approach based on mixture modelling provides additional improvements.

  10. Statistical methods for improving verification of claims of origin for Italian wines based on stable isotope ratios

    Energy Technology Data Exchange (ETDEWEB)

    Dordevic, N.; Wehrens, R. [IASMA Research and Innovation Centre, Fondazione Edmund Mach, via Mach 1, 38010 San Michele all' Adige (Italy); Postma, G.J.; Buydens, L.M.C. [Radboud University Nijmegen, Institute for Molecules and Materials, Analytical Chemistry, P.O. Box 9010, 6500 GL Nijmegen (Netherlands); Camin, F., E-mail: federica.camin@fmach.it [IASMA Research and Innovation Centre, Fondazione Edmund Mach, via Mach 1, 38010 San Michele all' Adige (Italy)

    2012-12-13

    Highlights: Black-Right-Pointing-Pointer The assessment of claims of origin is of enormous economic importance for DOC and DOCG wines. Black-Right-Pointing-Pointer The official method is based on univariate statistical tests of H, C and O isotopic ratios. Black-Right-Pointing-Pointer We consider 5220 Italian wine samples collected in the period 2000-2010. Black-Right-Pointing-Pointer Multivariate statistical analysis leads to much better specificity and easier detection of false claims of origin. Black-Right-Pointing-Pointer In the case of multi-modal data, mixture modelling provides additional improvements. - Abstract: Wine derives its economic value to a large extent from geographical origin, which has a significant impact on the quality of the wine. According to the food legislation, wines can be without geographical origin (table wine) and wines with origin. Wines with origin must have characteristics which are essential due to its region of production and must be produced, processed and prepared, exclusively within that region. The development of fast and reliable analytical methods for the assessment of claims of origin is very important. The current official method is based on the measurement of stable isotope ratios of water and alcohol in wine, which are influenced by climatic factors. The results in this paper are based on 5220 Italian wine samples collected in the period 2000-2010. We evaluate the univariate approach underlying the official method to assess claims of origin and propose several new methods to get better geographical discrimination between samples. It is shown that multivariate methods are superior to univariate approaches in that they show increased sensitivity and specificity. In cases where data are non-normally distributed, an approach based on mixture modelling provides additional improvements.

  11. Standard test method for analysis of total and isotopic uranium and total thorium in soils by inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the measurement of total uranium (U) and thorium (Th) concentrations in soils, as well as the determination of the isotopic weight percentages of 234U, 235U, 236U, and 238U, thereby allowing for the calculation of individual isotopic uranium activity or total uranium activity. This inductively coupled plasma-mass spectroscopy (ICP-MS) method is intended as an alternative analysis to methods such as alpha spectroscopy or thermal ionization mass spectroscopy (TIMS). Also, while this test method covers only those isotopes listed above, the instrumental technique may be expanded to cover other long-lived radioisotopes since the preparation technique includes the preconcentration of the actinide series of elements. The resultant sample volume can be further reduced for introduction into the ICP-MS via an electrothermal vaporization (ETV) unit or other sample introduction device, even though the standard peristaltic pump introduction is applied for this test method. The sample preparatio...

  12. Review of Electrical and Gravity Methods of Near-Surface Exploration for Groundwater

    Directory of Open Access Journals (Sweden)

    W. O. Raji

    2014-12-01

    Full Text Available The theory and practice of electrical and gravity methods of geophysics for groundwater exploration was reviewed with illustrations and data examples. With the goal of reducing cases of borehole/water-well failure attributed to the lack of the knowledge of the methods of geophysics for groundwater exploration and development, the paper reviews the basic concepts, field procedures for data acquisition, data processing, and interpretation as applied to the subject matter. Given a case study of groundwater exploration in University of Ilorin Campus, the three important techniques of electrical method of groundwater exploration are explained and illustrated using field data obtained in a previous study. Interpretation of resistivity data shows that an area measuring low resistivity (high conductivity, having thick pile of unconsolidated rock, and underlained by fracture crystalline is a ‘bright spot’ for citing borehole for groundwater abstraction in a basement complex area. Further to this, gravity method of groundwater exploration was discussed with field data from Wokbedilo community in Ethopia. Bouguer and reduced gravity anomaly results were presented as maps and contours to demonstrate how gravity data can be inverted to map groundwater aquifers and subsurface geological structures during groundwater exploration.

  13. The strengths and limitations of effective centroid force models explored by studying isotopic effects in liquid water

    Science.gov (United States)

    Yuan, Ying; Li, Jicun; Li, Xin-Zheng; Wang, Feng

    2018-05-01

    The development of effective centroid potentials (ECPs) is explored with both the constrained-centroid and quasi-adiabatic force matching using liquid water as a test system. A trajectory integrated with the ECP is free of statistical noises that would be introduced when the centroid potential is approximated on the fly with a finite number of beads. With the reduced cost of ECP, challenging experimental properties can be studied in the spirit of centroid molecular dynamics. The experimental number density of H2O is 0.38% higher than that of D2O. With the ECP, the H2O number density is predicted to be 0.42% higher, when the dispersion term is not refit. After correction of finite size effects, the diffusion constant of H2O is found to be 21% higher than that of D2O, which is in good agreement with the 29.9% higher diffusivity for H2O observed experimentally. Although the ECP is also able to capture the redshifts of both the OH and OD stretching modes in liquid water, there are a number of properties that a classical simulation with the ECP will not be able to recover. For example, the heat capacities of H2O and D2O are predicted to be almost identical and higher than the experimental values. Such a failure is simply a result of not properly treating quantized vibrational energy levels when the trajectory is propagated with classical mechanics. Several limitations of the ECP based approach without bead population reconstruction are discussed.

  14. High mass isotope separation arrangement

    International Nuclear Information System (INIS)

    Eerkens, J.W.

    1980-01-01

    This invention relates to the isotope separation art and, more particularly, to a selectively photon-induced energy level transition of an isotopic molecule containing the isotope to be separated and a chemical reaction with a chemically reactive agent to provide a chemical compound containing atoms of the isotope desired. In particular a description is given of a method of laser isotope separation applied to the separation of 235 UF 6 from 238 UF 6 . (U.K.)

  15. Geochemical and isotopic methods for management of artificial recharge in mazraha station (Damascus)

    International Nuclear Information System (INIS)

    Abou Zakhem, B.; Hafez, R.; Kadkoy, N.

    2009-11-01

    Artificial recharge of shallow groundwater at specially designed facilities is an attractive option increasing the storage capacity of potable water in arid and semi arid region such as Syria, Damascus Oasis. This operation needs integral management and detailed knowledge of groundwater dynamics and quantity and quality development of water. The objective of this study is to determine the temporal and spatial variations of chemical and environmental isotopic characteristics of groundwater during injection and recovery process. The geochemical and environmental isotope techniques are ideally suited for these investigations. 400 to 500 x10 3 m 3 of spring water were injected annually into the ambient groundwater in Mazraha station, Damascus Oasis, which is used later for drinking purpose. Native groundwater and injected water are calcium bicarbonate type with EC of about 850±100 μS/cm and 300±50 μS/cm respectively. The injected water is under saturated with respect to calcite, while ambient groundwater is over saturated and the mixed water is in equilibrium after injection. It was observed that The injection process created a dilution cloud decreasing chemical concentrations progressively that improve the groundwater quality. After completed injection, the dilution center moved about 200 m during 85 days to the south southeast according to the ambient groundwater flow path. Based on this observation, the hydraulic conductivity of the aquifer is estimated about 7.5±1.3x10 -4 m/s. The spatial distribution maps of CFC-11 and CFC-12, after injection, showed the same shape and flow direction of the spatial distribution of chemical elements. The effective diameter of artificial recharge is limited to about 250 m from the injection wells, as EC, Cl- and NO 3 - concentrations are effected significantly. Mixing ratio of 30% is required in order to lower nitrate concentration to less than 50 mg/l in native groundwater for potable water. Depending on pumping rate, the

  16. An exploration of learning to link with Wikipedia: features, methods and training collection

    NARCIS (Netherlands)

    He, J.; de Rijke, M.

    2010-01-01

    We describe our participation in the Link-the-Wiki track at INEX 2009. We apply machine learning methods to the anchor-to-best-entry-point task and explore the impact of the following aspects of our approaches: features, learning methods as well as the collection used for training the models. We

  17. Square Pegs, Round Holes: An Exploration of Teaching Methods and Learning Styles of Millennial College Students

    Science.gov (United States)

    Bailey, Regina M.

    2012-01-01

    In an information-saturated world, today's college students desire to be engaged both in and out of their college classrooms. This mixed-methods study sought to explore how replacing traditional teaching methods with engaged learning activities affects millennial college student attitudes and perceptions about learning. The sub-questions…

  18. Comparing Management Models of Secondary Schools in Tamaulipas, Mexico: An Exploration with a Delphi Method

    Science.gov (United States)

    Navarro-Leal, Marco Aurelio; Garcia, Concepcion Nino; Saldivar, Luisa Caballero

    2012-01-01

    For a preliminary exploration of management models between two secondary schools, a Delphi method was used in order to identify and focus relevant topics for a larger research. A first approximation with this method proved to be a heuristic tool to focus and define some categories and guidelines of enquiry. It was found that in both of the schools…

  19. Calculations of energy levels and electromagnetic properties for tellurium pair isotopes, by unified method

    International Nuclear Information System (INIS)

    Teixeira, R.R.P.

    1988-01-01

    Calculations with the Unified Model (vibrator coupled to two particles), of the energy levels and the eletromagnetic properties have been performed and compared with the twelve pair isotopes from tellurium with A between 112 and 134. The results were analysed using as particles interaction: pairing and SDI (Surface Delta Interaction). The SDI and 3 fonons collective states were used in the fittings, and a syntematic comparison between the theoretical and experimental results was made. The dependence of the results with the model parameters was determined, through large variation sof them. Calculations using 4 fonons have been made, and the importance of the introduced variations in the results was discussed. Calculations have been made in the VAX Computer of the Pelletron at IFUSP. (author) [pt

  20. Fiscal 1996 verification survey of geothermal exploration technology. Development of the fracture type reservoir exploration method (development of the elastic wave use exploration method); 1996 nendo chinetsu tansa gijutsu nado kensho chosa. Danretsugata choryuso tansaho kaihatsu (danseiha riyo tansaho kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For the purpose of exploring accurately fracture groups greatly restricting the fluid flow of geothermal reservoirs, technical development was made for applying the elastic wave exploration technology such as the high precision reflection method, VSP, elastic wave tomography to the geothermal exploration. The Okiri area, Kagoshima prefecture was selected as a demonstrative field of a typical type where the steep and predominant fracture rules the geothermal reservoir, and experiments were conducted using the high precision reflection method and VSP. Fracture models were made, and the analysis results were studied by a survey using the array CSMT/MT method and by a comparison with existing data. Reformation of the underground receiving system used for VSP and elastic tomography is made for improvement of its viability, and was applied to the VSP experiment. The treatment/analysis system of the core analyzer was improved, and cores of the demonstrative field were analyzed/measured. Further, the exploration results, core analysis results and existing data were synthetically analyzed, and fracture models of the demonstrative field were constructed. Also, effectiveness and viability of the elastic wave use exploration method were studied. 90 refs., 418 figs., 24 tabs.

  1. A Fast Numerical Method for the Calculation of the Equilibrium Isotopic Composition of a Transmutation System in an Advanced Fuel Cycle

    Directory of Open Access Journals (Sweden)

    F. Álvarez-Velarde

    2012-01-01

    Full Text Available A fast numerical method for the calculation in a zero-dimensional approach of the equilibrium isotopic composition of an iteratively used transmutation system in an advanced fuel cycle, based on the Banach fixed point theorem, is described in this paper. The method divides the fuel cycle in successive stages: fuel fabrication, storage, irradiation inside the transmutation system, cooling, reprocessing, and incorporation of the external material into the new fresh fuel. The change of the fuel isotopic composition, represented by an isotope vector, is described in a matrix formulation. The resulting matrix equations are solved using direct methods with arbitrary precision arithmetic. The method has been successfully applied to a double-strata fuel cycle with light water reactors and accelerator-driven subcritical systems. After comparison to the results of the EVOLCODE 2.0 burn-up code, the observed differences are about a few percents in the mass estimations of the main actinides.

  2. Sub-stoichiometric isotope dilution analysis method for the determination of iodine in common salts using iodine-131 tracer

    International Nuclear Information System (INIS)

    Singh, Vivek; Garg, A.N.

    1994-01-01

    A sub-stoichiometric isotope dilution analysis (SIDA) method was developed for the determination of iodine in different brands of common salts. An aqueous salt solution containing 131 I tracer and NaI as carrier is oxidized by tartaric acid and KIO 3 and the liberated iodine is extracted with CCl 4 . To the extract an aqueous solution of AgNO 3 is added in substoichiometric amount to obtain a colloidal solution of AgI. On adding sodium thiosulfate solution, the NaI so formed passes into aqueous solution, which is then counted. Several different brands of salt were analysed. The method is especially suitable for the determination of microgram amounts of iodide in the presence of excess of chloride. (Author)

  3. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    Science.gov (United States)

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  4. A Method for the Selection of Exploration Areas for Unconformity Uranium Deposits

    International Nuclear Information System (INIS)

    Harris, DeVerle P.; Zaluski, Gerard; Marlatt, James

    2009-01-01

    The method we propose employs two analyses: (1) exploration simulation and risk valuation and (2) portfolio optimization. The first analysis, implemented by the investment worth system (IWS), uses Monte Carlo simulation to integrate a wide spectrum of uncertain and varied components to a relative frequency histogram for net present value of the exploration investment, which is converted to a risk-adjusted value (RAV). Iterative rerunning of the IWS enables the mapping of the relationship of RAV to magnitude of exploration expenditure, X. The second major analysis uses RAV vs. X maps to identify that subset (portfolio) of areas that maximizes the RAV of the firm's multiyear exploration budget. The IWS, which is demonstrated numerically, consists of six components based on the geologic description of a hypothetical basin and project area (PA) and a mix of hypothetical and actual conditions of an unidentified area. The geology is quantified and processed by Bayesian belief networks to produce the geology-based inputs required by the IWS. An exploration investment of $60 M produced a highly skewed distribution of net present value (NPV), having mean and median values of $4,160 M and $139 M, respectively. For hypothetical mining firm Minex, the RAV of the exploration investment of $60 M is only $110.7 M. An RAV that is less than 3% of mean NPV reflects the aversion by Minex to risk as well as the magnitude of risk implicit to the highly skewed NPV distribution and the probability of 0.45 for capital loss. Potential benefits of initiating exploration of a portfolio of areas, as contrasted with one area, include increased marginal productivity of exploration as well as reduced probability for nondiscovery. For an exogenously determined multiyear exploration budget, a conceptual framework for portfolio optimization is developed based on marginal RAV exploration products for candidate PAs. PORTFOLIO, a software developed to implement optimization, allocates exploration to

  5. Maintaining and assessing extended 9 test methods in accordance with ISO/IEC 17025: 2005 for Isotopes Hydrology Laboratory

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Tran Khanh Minh; Vu Hoai

    2016-01-01

    The ISO/IEC 17025:2005 ''General requirements for the competence of testing and calibration laboratories'' is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technique and management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed and maintain a quality management system in accordance with ISO/IEC 17025:2005. In 2013, Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO/IEC 17025:2005 with VILAS 670 accredited code. Scope of recognition is analyzed 14 parameters: F"-, Cl"-, NO_2"-, NO_3"-, Br"-, PO_4"3"-, SO_4"2"-, Li"+, Na"+, NH_4"+, K"+, Mg"2"+, Ca"2"+ and "3H in water by ion chromatography and liquid scintillator counting method. The laboratory has successfully implemented the task of maintaining quality management systems conform to ISO/IEC 17025: 2005 and expanded the scope of accreditation by 9 parameters in water: pH, EC, TSS, TDS, DO, BOD5, pH, Fe and Mn in 2015. (author)

  6. Hybrid quantum and classical methods for computing kinetic isotope effects of chemical reactions in solutions and in enzymes.

    Science.gov (United States)

    Gao, Jiali; Major, Dan T; Fan, Yao; Lin, Yen-Lin; Ma, Shuhua; Wong, Kin-Yiu

    2008-01-01

    A method for incorporating quantum mechanics into enzyme kinetics modeling is presented. Three aspects are emphasized: 1) combined quantum mechanical and molecular mechanical methods are used to represent the potential energy surface for modeling bond forming and breaking processes, 2) instantaneous normal mode analyses are used to incorporate quantum vibrational free energies to the classical potential of mean force, and 3) multidimensional tunneling methods are used to estimate quantum effects on the reaction coordinate motion. Centroid path integral simulations are described to make quantum corrections to the classical potential of mean force. In this method, the nuclear quantum vibrational and tunneling contributions are not separable. An integrated centroid path integral-free energy perturbation and umbrella sampling (PI-FEP/UM) method along with a bisection sampling procedure was summarized, which provides an accurate, easily convergent method for computing kinetic isotope effects for chemical reactions in solution and in enzymes. In the ensemble-averaged variational transition state theory with multidimensional tunneling (EA-VTST/MT), these three aspects of quantum mechanical effects can be individually treated, providing useful insights into the mechanism of enzymatic reactions. These methods are illustrated by applications to a model process in the gas phase, the decarboxylation reaction of N-methyl picolinate in water, and the proton abstraction and reprotonation process catalyzed by alanine racemase. These examples show that the incorporation of quantum mechanical effects is essential for enzyme kinetics simulations.

  7. Assay of cortisol with a radioimmunoassay method calibrated by isotope dilution-mass spectrometry. A Nordic collaborative study

    International Nuclear Information System (INIS)

    Lantto, O.; Lindback, B.; Aakvaag, A.; Bjoerkhem, I.; Damkjaer-Nielsen, M.; Pomoell, U.M.; Helsinki University Hospital

    1983-01-01

    A reference method for serum cortisol, based on isotope dilution-mass spectrometry (ID-MS), was compared with a modified commercial RIA method. The modification solely concerned the calibration standards used in the RIA method. These were replaced by a series of human serum samples, in which the concentration of cortisol had been determined by the reference ID-MS method. Samples were selected to cover the whole range of the standard curve. Serum samples from healthy, untreated subjects with cortisol concentrations 270-1134 nmol/l were analysed with the ID-MS calibrated RIA method in four laboratories, one in each of the four Nordic countries. Mean values based on results from all four laboratories were almost identical with the values obtained with the reference method. Serum samples from 11 patients with endocrine disorders with cortisol concentrations 31-916 nmol/l were analysed in three of the four laboratories. In three of the samples significant differences were observed between the values obtained with the ID-MS and the ID-MS calibrated RIA method. The value obtained with the ID-MS calibrated RIA was however always more accurate than the corresponding value obtained with RIA with the use of a commercial calibration standard. (author)

  8. Wide angle isotope separator

    International Nuclear Information System (INIS)

    Kantrowitz, A.

    1976-01-01

    A method and apparatus is described for particle separation. The method uses a wide angle radially expanding vapor of a particle mixture. In particular, selective ionization of one isotope type in the particle mixture is produced in a multichamber separator and the ionized isotope type is accelerated out of the path of the vapor expansion for separate collection

  9. Origin and evolution of mineralizing fluids and exploration of the Cerro Quema Au-Cu deposit (Azuero Peninsula, Panama) from a fluid inclusion and stable isotope perspective

    Science.gov (United States)

    Corral, Isaac; Cardellach, Esteve; Corbella, Merce; Canals, Angels; Griera, Albert; Gomez-Gras, David; Johnson, Craig A.

    2017-01-01

    D from − 103.3 to − 35.2‰, whereas the δ18O of dickite varies between 12.7 and 16.3‰ and δD from − 44 to − 30. Based on δ18O and δD, two types of kaolinite/dickite can be distinguished, a supergene type and a hypogene type. Combined, the analytical data indicate that the Cerro Quema deposit formed from magmatic-hydrothermal fluids derived from a porphyry copper-like intrusion located at depth likely towards the east of the deposit. The combination of stable isotope geochemistry and fluid inclusion analysis may provide useful exploration vectors for porphyry copper targets in the high sulfidation/lithocap environment.

  10. The application of the signal flow graph method to charged-particle optics - the formula derivation of a three-sector isotope separator

    International Nuclear Information System (INIS)

    Lu Hongyou; Zhao Zhiyong; Sun Quinren

    1987-01-01

    A brief introduction of the Signal Flow Graph (SFG) method is given. The application of it to charged-particle optics (CPO) is described. The method has the advantages of simplicity, visualisation and computerisation. An example of the application of SFG is given for the design of a three-sector electromagnetic isotope separator. (orig.)

  11. Isotope dilution/mass spectrometry of serum cholesterol with [3,4-13C]cholesterol: proposed definitive method

    International Nuclear Information System (INIS)

    Pelletier, O.; Wright, L.A.; Breckenridge, W.C.

    1987-01-01

    We describe a new gas-chromatographic/mass-spectrometric (GC/MS) isotope-dilution method for determination of serum cholesterol. The method has been fully optimized and documented to provide the high accuracy and precision expected for a Definitive Method. In the presence of [3,4- 13 C]cholesterol, cholesteryl esters in serum are hydrolyzed under optimum conditions and the entire cholesterol pool is extracted and derivatized to silyl ethers. The cholesterol derivatives are resolved from other sterols by gas-liquid chromatography on a fused silica column, and selected ions characteristic of cholesterol and the [3,4- 13 C]cholesterol are monitored with a GC/MS quandrupole system. We estimated the cholesterol content of samples by bracketing each sample with standards of comparable cholesterol concentration that also contained the [3,4- 13 C]cholesterol. The procedure was highly reproducible (CV less than 0.5%), better accuracy and precision being obtained with [3,4- 13 C]cholesterol than with heptadeuterated cholesterol. Mean values per gram of dry serum for one serum pool assayed by this method and that of the National Bureau of Standards differed by 0.5%. We conclude that the method satisfies the criteria for a Definitive Method

  12. An efficient method for extracting plasma ions in laser isotope separation systems

    International Nuclear Information System (INIS)

    Demidova, N.S.; Mishin, V.A.

    2000-01-01

    The possibility of using a Hall-current accelerator to extract ions from a partially ionized plasma produced by selective laser isotope photoionization of atomic vapor is examined. A mechanism for ion acceleration is investigated using one-dimensional time-dependent equations of two-fluid magnetohydrodynamics. The current cutoff due to the ion space charge is prevented by electron emission. It is shown that, at an accelerating voltage of 25-50 V and emission current density of several mA/cm 2 , the ion component is accelerated throughout the entire plasma volume up to a velocity of ∼10 5 cm/s in a few microseconds. The influence of resonant charge exchange and secondary ionization by electrons on both the acceleration dynamics and selectivity degradation is taken into account. It is shown that the Hall-current extractor allows one to avoid selectivity degradation even when the plasma size exceeds the charge-exchange mean free path by one order of magnitude

  13. Isotope methods as a tool for Quaternary studies in Saudi Arabia

    International Nuclear Information System (INIS)

    Hoetzl, H.; Job, C.; Moser, H.; Rauert, W.; Stichler, W.

    1980-01-01

    Within the framework of a combined sedimentological, hydrogeological, hydrochemical, geomorphical and climatological investigation in central and eastern Saudi Arabia various environmental isotope studies were performed. 14 C measurements on shells from different shell banks in the Gulf coastal region confirmed the existence of sea-level fluctuations during the Wuerm time and during the Holocene. Measurements of 2 H, 18 O, and 3 H contents of water samples from the Al Qatif and Al Hasa areas gave valuable information on the origin and the fate of these waters as well as on hydraulic connections between aquifer strata. 14 C measurements on calcite crusts in the region As Sulb Plateau confirm that the precipitation of the ''Neolithic Pluvial'' reactivated the karst development in this region. In its southwestern part, different 14 C values of stalactites and of duricrust cementing the stalactites show the development of duricrust during late Pleistocene and/or Holocene. In the upper part of Wadi Ar Rimah, a close insight into the causes of salination of groundwaters was obtained by studying their contents of 2 H, 18 O, and 3 H in combination with hydrochemical data. It is shown that secondary and tertiary evaporation during irrigation and infiltration must be taken into consideration. In Wadi Ad Dawasir and its hinterland the 2 H and 18 O enrichment and that of the mineralization in hand-dug wells were explained by an admixture of recent shallow groundwater with old sandstone water. (author)

  14. Biological nitrogen fixation in Crotalaria species estimated using the 15N isotope dilution method

    International Nuclear Information System (INIS)

    Samba, R.T.; Neyra, M.; Gueye, M.; Sylla, S.N.; Ndoye, I.; Dreyfus, B.

    2002-01-01

    Growing in Senegal by using 15 N direct isotope dilution technique. Two non-fixing plants, Senna obtusifolia and Senna occidentalis served as reference plants. The amount of nitrogen fixed two months after planting was obtained using the average of the two reference plants. The atom % 15 N excess in the Crotalaria species was significantly lower than that of the reference plants, indicating that significant nitrogen fixation occurred in the three plants. Significant differences were observed between the Crotalaria species; C. ochroleuca yielded more dry matter weight and total nitrogen than did C. perrottetti and C. retusa. The % nitrogen derived from atmosphere (%Ndfa) in leaves and stems was also higher in C. ochroleuca. There was no significant difference in %Ndfa in the whole plant between the three Crotalaria species (47% to 53%). In contrast, interspecific variability was observed based on the %Ndfa. C. ochroleuca significantly exhibited the higher amount of total nitrogen fixed, equivalent to 83 kg of nitrogen fixed per hectare. Based on these data, it was concluded that C. ochroleuca could be used in multiple cropping systems in Senegal for making more nitrogen available to other plants. (author)

  15. Study of mass transfer at the air-water interface by an isotopic method

    International Nuclear Information System (INIS)

    Merlivat, L.

    1975-01-01

    It is shown by analysing the hydrogen and oxygen stable isotopes distribution in liquid and water vapor, that the processes taking place on a very small scale near the liquid can be investigated. The effect of molecular mass transfer is directly obtained without having to perform difficult measurements in the air in the immediate vicinity of the water surface. Experiments are carried out in the air-water tunnel especially designed for the simulation of ocean atmosphere energy exchanges. The wind velocities vary from 0.7 to 7m/sec. The experimental results obtained do not support the classical Reynolds' analogy between momentum and mass transfer down to the interface and the theory proposed by Sheppard, but they are in agreement with Sverdrup's, Kitaigorodskiy and Volkov's and Brutsaert's theories, all of which involve a layer just above the air-water interface through which mass transfer is dominated by molecular diffusion. The thickness of this layer in the two first theories is shown to decrease with increasing wind velocity. Direct application of Brutsaert's theory for roughness Reynolds numbers smaller than one is in good agreement with the experimental data obtained [fr

  16. Method and apparatus for suppressing electron generation in a vapor source for isotope separation

    International Nuclear Information System (INIS)

    Janes, G.S.

    1979-01-01

    A system for applying accelerating forces to ionized particles of a vapor in a manner to suppress the flow of electron current from the vapor source. The accelerating forces are applied as an electric field in a configuration orthogonal to a magnetic field. The electric field is applied between one or more anodes in the plasma and one or more cathodes operated as electron emitting surfaces. The circuit for applying the electric field floats the cathodes with respect to the vapor source, thereby removing the vapor source from the circuit of electron flow through the plasma and suppressing the flow of electrons from the vapor source. The potential of other conducting structures contacting the plasma is controlled at or permitted to seek a level which further suppresses the flow of electron currents from the vapor source. Reducing the flow of electrons from the vapor source is particularly useful where the vapor is ionized with isotopic selectivity because it avoids superenergization of the vapor by the electron current

  17. Improvement of Particle Recovery Method for Uranium Isotope Analysis Using SIMS

    International Nuclear Information System (INIS)

    Kim, Taehee; Park, Jinkyu; Lee, Chi-Gyu; Lim, Sang Ho; Han, Sun-Ho

    2017-01-01

    In this study, we developed a new design of vacuum-suction impactor with wider inlet nozzle and outlet nozzle for guiding particles to disperse the particles on the surface of carbon planchet. We prepared simulated samples with lead dioxide and examined particle recovery yield and degree of dispersion using the conventional vacuum impactor and the newly designed ones with different inlet nozzle diameters. We tried to improve the inlet part of vacuum impactor, in order to increase the recovery yield and disperse the collected particle on carbon planchet. As the diameter of inlet nozzle became larger, the collected particles were better dispersed on planchet. In addition, when the inner diameter of the impactor was 3 mm or 5 mm, the recovery yield was higher than that of conventional impactor. Considering the degree of dispersion and recovery yield, we used the impactor with 5 mm exit diameter and recovered the mixed uranium standard materials for SIMS measurement. We were able to reduce the mixing effect and measure the isotopic ratio more accurately and precisely.

  18. Project-Method Fit: Exploring Factors That Influence Agile Method Use

    Science.gov (United States)

    Young, Diana K.

    2013-01-01

    While the productivity and quality implications of agile software development methods (SDMs) have been demonstrated, research concerning the project contexts where their use is most appropriate has yielded less definitive results. Most experts agree that agile SDMs are not suited for all project contexts. Several project and team factors have been…

  19. Exploring Reticence in Research Methods: The Experience of Studying Psychological Research Methods in Higher Education

    Science.gov (United States)

    Kingsley, Barbara E.; Robertson, Julia M.

    2017-01-01

    As a fundamental element of any psychology degree, the teaching and learning of research methods is repeatedly brought into sharp focus, and it is often regarded as a real challenge by undergraduate students. The reasons for this are complex, but frequently attributed to an aversion of maths. To gain a more detailed understanding of students'…

  20. Electron screening effects in (p,α) reactions induced on boron isotopes studied via the Trojan Horse Method

    International Nuclear Information System (INIS)

    Lamia, L; Spitaleri, C; Cherubini, S; Gulino, M; Puglia, S M R; Rapisarda, G G; Romano, S; Sergi, M L; Carlin, N; Gameiro Munhoz, M; Gimenez Del Santo, M; Kiss, G G; Somorjai, E; Kroha, V; Kubono, S; La Cognata, M; Pizzone, R G; Li, C; Wen, Qungang; Mukhamedzhanov, A

    2013-01-01

    The Trojan Horse Method is a powerful indirect technique allowing one to measure the bare nucleus S(E)-factor and the electron screening potential for astrophysically relevant reactions without the needs of extrapolations. The case of the (p,α) reactions induced on the two boron isotopes 10,11 B is here discussed in view of the recent Trojan Horse (TH) applications to the quasi-free 10,11 B+ 2 H reactions. The comparison between the TH and the low-energy direct data allowed us to determine the electron screening potential for the 11 B(p,α) reaction, while preliminary results on the 10 B(p,α) reaction have been extracted.

  1. "I See What You Mean": Using Visual Data Collection Methods to Explore Leadership Curriculum Planning

    Science.gov (United States)

    Reid, Anna; Koglbauer, René

    2018-01-01

    This article reports on the use of a visual methods approach to collecting and analysing data in relation to the area of leadership curriculum development. The focus of the study is the structure of the current leadership curriculum for the National Professional Qualifications (NPQs) in England. In particular, the authors explore the extent to…

  2. Perceived Family Support, Acculturation, and Life Satisfaction in Mexican American Youth: A Mixed-Methods Exploration

    Science.gov (United States)

    Edwards, Lisa M.; Lopez, Shane J.

    2006-01-01

    In this article, the authors describe a mixed-methods study designed to explore perceived family support, acculturation, and life satisfaction among 266 Mexican American adolescents. Specifically, the authors conducted a thematic analysis of open-ended responses to a question about life satisfaction to understand participants' perceptions of…

  3. Interactively Applying the Variational Method to the Dihydrogen Molecule: Exploring Bonding and Antibonding

    Science.gov (United States)

    Cruzeiro, Vinícius Wilian D.; Roitberg, Adrian; Polfer, Nicolas C.

    2016-01-01

    In this work we are going to present how an interactive platform can be used as a powerful tool to allow students to better explore a foundational problem in quantum chemistry: the application of the variational method to the dihydrogen molecule using simple Gaussian trial functions. The theoretical approach for the hydrogen atom is quite…

  4. Exploring Service Learning Outcomes in Students: A Mixed Methods Study for Nursing

    Science.gov (United States)

    Martin, John F.

    2017-01-01

    This mixed methods study exploring student outcomes of service learning experiences is inter-disciplinary, near the intersection of higher education research, moral development, and nursing. The specific problem examined in this study is that service learning among university students is utilized by educators, but largely without a full…

  5. Exploring the Changes in Students' Understanding of the Scientific Method Using Word Associations

    Science.gov (United States)

    Gulacar, Ozcan; Sinan, Olcay; Bowman, Charles R.; Yildirim, Yetkin

    2015-01-01

    A study is presented that explores how students' knowledge structures, as related to the scientific method, compare at different student ages. A word association test comprised of ten total stimulus words, among them "experiment," "science fair," and "hypothesis," is used to probe the students' knowledge structures.…

  6. Idea Generation and Exploration: Benefits and Limitations of the Policy Delphi Research Method

    Science.gov (United States)

    Franklin, Kathy K.; Hart, Jan K.

    2007-01-01

    Researchers use the policy Delphi method to explore a complex topic with little historical context that requires expert opinion to fully understand underlying issues. The benefit of this research technique is the use of experts who have more timely information than can be gleamed from extant literature. Additionally, those experts place…

  7. Language Learning Motivation in Early Adolescents: Using Mixed Methods Research to Explore Contradiction

    Science.gov (United States)

    Wesely, Pamela M.

    2010-01-01

    This mixed methods study with an Explanatory Design is an exploration of students' language learning motivation as it relates to their attrition from a language immersion program. A total of 131 students who had graduated from five public elementary immersion schools responded to surveys, and 33 of those students were interviewed. Data analysis…

  8. Experimental assessment of the purity of α-cellulose produced by variations of the Brendel method: Implications for stable isotope (δ13C, δ18O) dendroclimatology

    Science.gov (United States)

    Brookman, Tom; Whittaker, Thomas

    2012-09-01

    Stable isotope dendroclimatology using α-cellulose has unique potential to deliver multimillennial-scale, sub-annually resolved, terrestrial climate records. However, lengthy processing and analytical methods often preclude such reconstructions. Variants of the Brendel extraction method have reduced these limitations, providing fast, easy methods of isolating α-cellulose in some species. Here, we investigate application of Standard Brendel (SBrendel) variants to resinous soft-woods by treating samples of kauri (Agathis australis), ponderosa pine (Pinus ponderosa) and huon pine (Lagarastrobus franklinii), varying reaction vessel, temperature, boiling time and reagent volume. Numerous samples were visibly `under-processed' and Fourier Transform infrared spectroscopic (FTIR) investigation showed absorption peaks at 1520 cm-1 and ˜1600 cm-1 in those fibers suggesting residual lignin and retained resin respectively. Replicate analyses of all samples processed at high temperature yielded consistent δ13C and δ18O despite color and spectral variations. Spectra and isotopic data revealed that α-cellulose δ13C can be altered during processing, most likely due to chemical contamination from insufficient acetone removal, but is not systematically affected by methodological variation. Reagent amount, temperature and extraction time all influence δ18O, however, and our results demonstrate that different species may require different processing methods. FTIR prior to isotopic analysis is a fast and cost effective way to determine α-cellulose extract purity. Furthermore, a systematic isotopic test such as we present here can also determine sensitivity of isotopic values to methodological variables. Without these tests, isotopic variability introduced by the method could obscure or `create' climatic signals within a data set.

  9. A protocol for pressurized liquid extraction and processing methods to isolate modern and ancient bone cholesterol for compound-specific stable isotope analysis.

    Science.gov (United States)

    Laffey, Ann O; Krigbaum, John; Zimmerman, Andrew R

    2017-02-15

    Bone lipid compound-specific isotope analysis (CSIA) and bone collagen and apatite stable isotope ratio analysis are important sources of ecological and paleodietary information. Pressurized liquid extraction (PLE) is quicker and utilizes less solvent than traditional methods of lipid extraction such as soxhlet and ultrasonication. This study facilitates dietary analysis by optimizing and testing a standardized methodology for PLE of bone cholesterol. Modern and archaeological bones were extracted by PLE using varied temperatures, solvent solutions, and sample weights. The efficiency of PLE was assessed via quantification of cholesterol yields. Stable isotopic ratio integrity was evaluated by comparing isotopic signatures (δ 13 C and δ 18 O values) of cholesterol derived from whole bone, bone collagen and bone apatite. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography isotope ratio mass spectrometry (GC/IRMS) were conducted on purified collagen and lipid extracts to assess isotopic responses to PLE. Lipid yield was optimized at two PLE extraction cycles of 75 °C using dichloromethane/methanol (2:1 v/v) as a solvent with 0.25-0.75 g bone sample. Following lipid extraction, saponification combined with the derivatization of the neutral fraction using trimethylsilylation yielded nearly twice the cholesterol of non-saponified or non-derivatized samples. It was also found that lipids extracted from purified bone collagen and apatite could be used for cholesterol CSIA. There was no difference in the bulk δ 13 C values of collagen extracted from bone with or without lipid. However, there was a significant depletion in 18 O of bone apatite due to lipid presence or processing. These results should assist sample selection and provide an effective, alternative extraction method for bone cholesterol that may be used for isotopic and paleodietary analysis. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. A method for exploring the distribution of radioelements at depth using gamma-ray spectrometric data

    International Nuclear Information System (INIS)

    Li Qingyang

    1997-01-01

    Based on the inherent relation between radioelements and terrestrial heat flow, theoretically shows the possibility of exploring the distribution of radioelements at depth using gamma-ray spectrometric data, and a data-processing and synthesizing method has been adopted to deduce the calculation formula. The practical application in the uranium mineralized area No. 2801 in Yunnan Province proves that this method is of practical value, and it has been successfully applied to the data processing and good results have been obtained

  11. Stable carbon and hydrogen isotope analysis of methyl tert-butyl ether and tert-amyl methyl ether by purge and trap-gas chromatography-isotope ratio mass spectrometry: method evaluation and application.

    Science.gov (United States)

    Kujawinski, Dorothea M; Stephan, Manuel; Jochmann, Maik A; Krajenke, Karen; Haas, Joe; Schmidt, Torsten C

    2010-01-01

    In order to monitor the behaviour of contaminants in the aqueous environment effective enrichment techniques often have to be employed due to their low concentrations. In this work a robust and sensitive purge and trap-gas chromatography-isotope ratio mass spectrometry method for carbon and hydrogen isotope analysis of fuel oxygenates in water is presented. The method evaluation included the determination of method detection limits, accuracy and reproducibility of deltaD and delta(13)C values. Lowest concentrations at which reliable delta(13)C values could be determined were 5 microg L(-1) and 28 microg L(-1) for TAME and MTBE, respectively. Stable deltaD values for MTBE and TAME could be achieved for concentrations as low as 25 and 50 microg L(-1). Good long-term reproducibility of delta(13)C and deltaD values was obtained for all target compounds. But deltaD values varying more than 5 per thousand were observed using different thermal conversion tubes. Thus, a correction of deltaD values in the analysis of groundwater samples was necessary to guarantee comparability of the results. The applicability of this method was shown by the analysis of groundwater samples from a gasoline contaminated site. By two dimensional isotope analysis two locations within this site were identified at which anaerobic and aerobic degradation of methyl tert-butyl ether occurred.

  12. Applications of isotopes

    International Nuclear Information System (INIS)

    Kirby-Smith, J.S.

    1976-01-01

    Current and potential applications of stable isotopes as tracers in a number of biomedical and environmental areas are discussed. It is pointed out that a wide variety of problems exist in these fields whose solutions in principle are amenable to the isotopic approach. The number and diversity of these problems as well as the unique role stable isotopes can play in their solution illustrate the importance of achieving and maintaining a broad inventory of isotopic species. Experience has demonstrated unequivocally an additional overriding requirement for widespread exploration of stable isotopes by the scientific and technical community, i.e., the need for low cost availability of the materials in quantity. Some representative applications of 12 C, 13 C, 14 N, 15 N, 16 O, 17 O, and 18 O are discussed

  13. A comprehensive review of the use of computational intelligence methods in mineral exploration

    Directory of Open Access Journals (Sweden)

    Habibollah Bazdar

    2017-11-01

    Full Text Available Introduction Mineral exploration is a process by which it is decided whether or not continuing explorations at the end of each stage t will be cost-effective or not. This decision is dependent upon many factors including technical factors, economic, social and other related factors. All new methods used in mineral exploration are meant to make this decision making more simplified. In recent years, advanced computational intelligence methods for modeling along with many other disciplines of science, including the science of mineral exploration have been used. Although the results of the application of these methods show a good performance, it is essential to determine the mineral potential in terms of geology, mineralogy, petrology and other factors for a final decision. The purpose of this paper is to provide a comprehensive set of mineral exploration research and different applications of computational intelligence techniques in this respect during the last decades. Materials and methods Artificial neural network and its application in mineral exploration Artificial neural network (ANN is a series of communications between the units or nodes that try to function like neurons of the human brain (Jorjani et al., 2008. The network processing capability of communication between the units and the weights connection originates or comes from learning or are predetermined (Monjezi and Dehghani, 2008. The ANN method has been applied in different branches of mining exploration in the last decades (Brown et al., 2000; Leite and de Souza Filho, 2009; Porwal et al., 2003. Support vector machines (SVM and its application in mineral exploration SVM uses a set of examples with known class of information to build a linear hyperplane separating samples of different classes. This initial dataset is known as a training set and every sample within it is characterized by features upon which the classification is based (Smirnoff et al., 2008. The SVM classifier is a

  14. Isotope separation process

    International Nuclear Information System (INIS)

    Lyon, R.K.

    1976-01-01

    The instant invention relates to a process for separating a material into two or more parts in each of which the abundances of the isotopes of a given element differ from the abundances of the isotopes of the same material in said material. In one embodiment, the invention relates to a method for the isotopically selective excitation of gas phase molecules by multiple infrared photon absorption followed by selective dissociation of said excited molecules by the absorption of a single photon of visible or ultraviolet light. This invention is useful for, but not limited to, the separation of the principal isotopes of uranium. 11 Claims, 2 Drawing Figures

  15. Use of isotope and radiation methods in soil and water management and crop nutrition. Manual

    International Nuclear Information System (INIS)

    2001-01-01

    This publication is a replacement for the IAEA Training Course Series No. 2 'Use of Nuclear Techniques in Studies of Soil-Plant Relationships' published in 1990. This edition, prepared by staff of the Soil Science Unit, Seibersdorf, and the Soil and Water Management and Crop Nutrition Section, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture, Vienna, differs in many respects from its predecessor both in terms of content and objectives. The earlier publication provided basic information for use in interregional training courses held at regular intervals at the Seibersdorf Laboratories. Since the discontinuation of these training courses in 1996, the need for dissemination of up to date information to Member States has become more acute, particularly in view of the evolution of new methodologies during the past decade and new applications of existing methodologies to monitor the dynamics of soil, water and nutrients in cropping systems, and to pilot test interventions to conserve the natural resource base and optimize the availability of water and nutrients to crops. The present publication attempts to fulfill a part of this need. The manual provides an overview of the use of nuclear techniques in soil science and plant nutrition, balancing the need for a comprehensive coverage of a multitude of techniques involving isotopic tracers and sealed or unsealed sources, while giving sufficient depth to be of practical value to the end-users - students, technicians, scientists in national agricultural research systems and fellowship trainees. In this respect it is important to emphasize that nuclear techniques do not in themselves provide solutions to real world problems - they provide tools which when used in conjunction with other techniques, provide precise and specific information necessary to understand system dynamics and hence the value of alternative management practices to improve system productivity and resource conservation. This publication

  16. Use of isotope and radiation methods in soil and water management and crop nutrition. Manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-01

    This publication is a replacement for the IAEA Training Course Series No. 2 'Use of Nuclear Techniques in Studies of Soil-Plant Relationships' published in 1990. This edition, prepared by staff of the Soil Science Unit, Seibersdorf, and the Soil and Water Management and Crop Nutrition Section, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture, Vienna, differs in many respects from its predecessor both in terms of content and objectives. The earlier publication provided basic information for use in interregional training courses held at regular intervals at the Seibersdorf Laboratories. Since the discontinuation of these training courses in 1996, the need for dissemination of up to date information to Member States has become more acute, particularly in view of the evolution of new methodologies during the past decade and new applications of existing methodologies to monitor the dynamics of soil, water and nutrients in cropping systems, and to pilot test interventions to conserve the natural resource base and optimize the availability of water and nutrients to crops. The present publication attempts to fulfill a part of this need. The manual provides an overview of the use of nuclear techniques in soil science and plant nutrition, balancing the need for a comprehensive coverage of a multitude of techniques involving isotopic tracers and sealed or unsealed sources, while giving sufficient depth to be of practical value to the end-users - students, technicians, scientists in national agricultural research systems and fellowship trainees. In this respect it is important to emphasize that nuclear techniques do not in themselves provide solutions to real world problems - they provide tools which when used in conjunction with other techniques, provide precise and specific information necessary to understand system dynamics and hence the value of alternative management practices to improve system productivity and resource conservation. This publication

  17. Analytical Method for Carbon and Oxygen Isotope of Small Carbonate Samples with the GasBench Ⅱ-IRMS Device

    Directory of Open Access Journals (Sweden)

    LIANG Cui-cui

    2015-01-01

    Full Text Available An analytical method for measuring carbon and oxygen isotopic compositions of trace amount carbonate (>15 μg was established by Delta V Advantage isotope Ratio MS coupled with GasBench Ⅱ. Different trace amount (5-50 μg carbonate standard samples (IAEA-CO-1 were measured by GasBench Ⅱ with 12 mL and 3.7 mL vials. When the weight of samples was less than 40 μg and it was acidified in 12 mL vials, most standard deviations of the δ13C and δ18O were more than 0.1‰, which couldn’t satisfied high-precision measurements. When the weight of samples was greater than 15 μg and it was acidified in 3.7 mL vials, standard deviations for the δ13C and δ18O were 0.01‰-0.07‰ and 0.01‰-0.08‰ respectively, which satisfied high-precision measurements. Therefore, small 3.7 mL vials were used to increase the concentration of carbon dioxide in headspace, carbonate samples even less as 15 μg can be analyzed routinely by a GasBench Ⅱ continuous-flow IRMS. Meanwhile, the linear relationship between sample’s weight and peak’s area was strong (R2>0.993 2 and it can be used to determine the carbon content of carbonate samples.

  18. Separation of uranium isotopes

    International Nuclear Information System (INIS)

    Porter, J.T.

    1980-01-01

    Methods and apparatus are disclosed for separation of uranium isotopes by selective isotopic excitation of photochemically reactive uranyl salt source material at cryogenic temperatures, followed by chemical separation of selectively photochemically reduced U+4 thereby produced from remaining uranyl source material

  19. Isotope separation process

    International Nuclear Information System (INIS)

    Lyon, R.K.

    1979-01-01

    A method is described for the isotopically selective excitation of gas phase molecules by multiple infrared photon absorption after which more of the excited molecules than nonexcited molecules are converted to a chemically different form which may be separated by means known in the art. This invention is useful for, but not limited to, the separation of the principal isotopes of uranium

  20. A novel dual-isotope labelling method for distinguishing between soil sources of N2O

    NARCIS (Netherlands)

    Wrage, N.; Groenigen, van J.W.; Oenema, O.; Baggs, E.M.

    2005-01-01

    We present a novel O-18-N-15-enrichment method for the distinction between nitrous oxide (N2O) from nitrification, nitrifier denitrification and denitrification based on a method with single- and double-N-15-labelled ammonium nitrate. We added a new treatment with O-18-labelled water to quantify N2O

  1. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  2. A novel membrane inlet mass spectrometer method to measure ¹⁵NH4₄⁺ for isotope-enrichment experiments in aquatic ecosystems.

    Science.gov (United States)

    Yin, Guoyu; Hou, Lijun; Liu, Min; Liu, Zhanfei; Gardner, Wayne S

    2014-08-19

    Nitrogen (N) pollution in aquatic ecosystems has attracted much attention over the past decades, but the dynamics of this bioreactive element are difficult to measure in aquatic oxygen-transition environments. Nitrogen-transformation experiments often require measurement of (15)N-ammonium ((15)NH4(+)) ratios in small-volume (15)N-enriched samples. Published methods to determine N isotope ratios of dissolved ammonium require large samples and/or costly equipment and effort. We present a novel ("OX/MIMS") method to determine N isotope ratios for (15)NH4(+) in experimental waters previously enriched with (15)N compounds. Dissolved reduced (15)N (dominated by (15)NH4(+)) is oxidized with hypobromite iodine to nitrogen gas ((29)N2 and/or (30)N2) and analyzed by membrane inlet mass spectrometry (MIMS) to quantify (15)NH4(+) concentrations. The N isotope ratios, obtained by comparing the (15)NH4(+) to total ammonium (via autoanalyzer) concentrations, are compared to the ratios of prepared standards. The OX/MIMS method requires only small sample volumes of water (ca. 12 mL) or sediment slurries and is rapid, convenient, accurate, and precise (R(2) = 0.9994, p < 0.0001) over a range of salinities and (15)N/(14)N ratios. It can provide data needed to quantify rates of ammonium regeneration, potential ammonium uptake, and dissimilatory nitrate reduction to ammonium (DNRA). Isotope ratio results agreed closely (R = 0.998, P = 0.001) with those determined independently by isotope ratio mass spectrometry for DNRA measurements or by ammonium isotope retention time shift liquid chromatography for water-column N-cycling experiments. Application of OX/MIMS should simplify experimental approaches and improve understanding of N-cycling rates and fate in a variety of freshwater and marine environments.

  3. A novel method for collection of soil-emitted nitric oxide (NO) for natural abundance stable N isotope analysis

    Science.gov (United States)

    Yu, Z.; Elliott, E. M.

    2016-12-01

    The global inventory of NO emissions is poorly constrained with a large portion of the uncertainty attributed to soil NO emissions that result from soil abiotic and microbial processes. While natural abundance stable N isotopes (δ15N) in various soil N-containing compounds have proven to be a robust tracer of soil N cycling, soil δ15N-NO is rarely quantified mainly due to the diffuse nature, low concentrations, and high reactivity of soil-emitted NO. Here, we present the development and application of a dynamic flux chamber system capable of simultaneously measuring soil NO fluxes and collecting NO for δ15N-NO measurements. The system couples a widely used flow-through soil chamber with a NO collection train, in which NO can be converted to NO2 through O3 titration in a Teflon reaction coil, followed by NO2 collection in a 20% triethanolamine (TEA) solution as nitrite and nitrate for δ15N analysis using the denitrifier method. The efficiency of NO-NO2 conversion in the reaction coil and the recovery of NO in the TEA solution were determined experimentally and found to be quantitative (>99%) over a 10 to 749 ppbv NO mixing ratio range. An analytical NO tank (δ15N-NO=71.0±0.4‰) was used to calibrate the method for δ15N-NO analysis. The resulting accuracy and precision (1σ) of the method across various environmental conditions were 1.6‰ and 1.2‰, respectively. Using this new method, controlled laboratory incubations have been conducted to characterize NO emissions induced by rewetting of air-dried surface soil sampled from an urban forest. Pulsed NO emissions, up to 30 times higher than maximum soil NO emissions under steady state, were triggered upon the rewetting and lasted for next 36 hours. While the measured δ15N-NO over the course of the NO pulsing ranged from -52.0‰ and -34.6‰, reinforcing the notion that soil δ15N-NO is lower than those of fossil-fuel combustion sources, a transient δ15N-NO shift was captured immediately after the

  4. A new method for the determination of NO2 traces using isotope dilution and mass spectrometry analysis

    International Nuclear Information System (INIS)

    Stevens, C.; Barat, F.; Nguyen Nghi, H.

    1975-01-01

    A new method for the determination of NO 2 traces, in the order of 1ppb (10 -9 ), in atmosphere and stratosphere is described. The method consists in an isotope dilution technique using 15 NO 2 , followed by the reduction of NO 2 to N 2 and a mass spectrometry analysis. A known amount of 15 NO 2 is added to the air samples. Then, NO 2 is separated from H 2 O, HNO 3 , CO 2 and N 2 O and transferred to a SiO 2 reactor by trapping at -196 deg C. In the reactor NO 2 is reduced to N 2 by reaction with electrolytic Cu heated at 580 deg C. The mass 29/mass 30 ratio corresponding to 15 N 14 N and 15 N 15 N is determined by mass spectrometry. The sensitivity of the method depends on the contamination introduced during the analysis of the sample (reagents, separation and measuring devices). The contamination is reproducible and in the order of 4.5+-0.5 10 -2 mm 3 N 2 [fr

  5. Improved method for Hf separation from silicate rocks for isotopic analysis using Ln-spec resin column

    International Nuclear Information System (INIS)

    Shinjo, Ryuichi; Ginoza, Yuko; Meshesha, Daniel

    2010-01-01

    An improved chemical separation method for Hf isotope ratio measurement using both the thermal ionization mass spectrometer (TIMS) and the multiple collector-inductively coupled plasma-mass spectrometer (MC-ICP-MS) is presented in this paper. In the first column (2.5-ml Eichrom Ln-spec resin), Hf cut was collected with 2M HCl-0.2M HF after washing the major elements, HREE, Ti, Nb, and Zr. For further Hf purification, the second column (1-ml Ln-spec resin) chemistry was conducted in a manner similar to that of the first column. The first column is designed for treatment with a 0.5-g silicate rock sample for TIMS analysis. Thus, because the Hf amount required for MC-ICP-MS analysis is much lesser than that required for TIMS analysis, the column chemistry for MC-ICP-MS analysis can be scaled down, depending on the amount of digested sample. Although there is a need to improve the TIMS technique, the TIMS Hf data obtained for geological reference rocks and Ethiopian flood basalts after the application of the proposed separation methods are consistent, within analytical error, with the previously reported data obtained using the MC-ICP-MS. The advantages of the proposed method include a reduction in the amount of reagents used (hence, a consequent reduction in the blank contribution), reduction in the time required, and a simplified preparation requiring a fewer number of acids. (author)

  6. A method for combined Sr-Nd-Hf isotopic analysis of <10 mg dust samples: implication for ice core science

    Science.gov (United States)

    Ujvari, Gabor; Wegner, Wencke; Klötzli, Urs

    2017-04-01

    Aeolian mineral dust particles below the size of 10-20 μm often experience longer distance transport in the atmosphere, and thus Aeolian dust is considered an important tracer of large-scale atmospheric circulation. Since ice core dust is purely Aeolian in origin, discrimination of its potential source region(s) can contribute to a better understanding of past dust activity and climatic/environmental causes. Furthermore, ice core dust source information provides critical experimental constraints for model simulations of past atmospheric circulation patterns [1,2]. However, to identify dust sources in past dust archives such as ice cores, the mineralogy and geochemistry of the wind-blown dust material must be characterized. While the amount of dust in marine cores or common terrestrial archives is sufficient for different types of analyses and even for multiple repeat measurements, dust content in ice cores is usually extremely low even for the peak dusty periods such as the Last Glacial Maximum (LGM) (5-8 mg dust/kg ice; [3]). Since the most powerful dust fingerprinting methods, such as REE composition and Sr-Nd-Pb isotopic analyses are destructive there is a clear need to establish sequential separation techniques of Sr, Nd, Pb and other REEs to get the most information out of small (5-10 mg) dust samples recovered from ice cores. Although Hf isotopes have recently been added as a robust tool of aerosol/dust source discrimination (e.g. [4,5,6,7]), precise Hf isotopic measurements of small (reliable 176Hf/177Hf (and also 87Sr/86Sr, 143Nd/144Nd) ratios. Along with the standards 50, 10 and 5 mg aliquots of the fine (affected by acid treatment and these signatures are extremely stable both within run (0.000008 variability for the three aliquots, i.e. 0.15 ɛNd unit) and between runs of different laboratories (0.00006, ca 1 ɛNd unit). Hf isotopic compositions varied within 1 (NUS) and 5 ɛHf units (BEI) between the three aliquots, but the BEI sample always gave more

  7. An improved method for high precision measurement of chromium isotopes using double spike MC-ICP-MS

    Science.gov (United States)

    Zhu, J.; Wu, G. L.; Wang, X.; Zhang, L. X.; Han, G.

    2017-12-01

    Chormium(Cr) isotopes have been used to trace pollution processes and reconstruct paleo-redox conditions. However, the precise determination of Cr isotopes has still been challenged due to difficulties in purifying Cr from samples with low Cr content and complex matrices. Here we report an improved four-step column chromatographic procedure to separate Cr from matrix elements. Firstly, Cr in sample solution was mixed with 50Cr-54Cr double spike (the optimized 54Crspike/52Crsample = 0.4 and (50Cr/54Cr)spike = 1.3:1) was completely converted into Cr (III) in 8.5mol/L HCl and loaded onto 2ml of AG50W-X8(200-400m) resin conditioned with 11 mol/L HCl. The 2.65ml of eluent was adjusted to 4.5ml of 6mol/L HCl and immediately loaded onto a Bio-Rad column filled with 2ml of AG1-X8 anion resin (100-200m). These two steps can remove at least 99% of Ca, Fe and most matrix elements. Secondly, the 7.5ml of eluent was dried down and dissolved in 0.1ml of 0.5mol/L HNO3.before adding 2ml 4mol/L HF, which was then loaded onto 1ml of AG1-X8 anion resin (100-200m) to remove Ti and V. Finally, sample was dissolved in 0.1ml of 0.5 mol/L HNO3 and oxidized by 0.5mL 0.2 mol/L (NH4)2S2O8 and 4.4mL H2O, which was then centrifuged to remove Mn oxide, and supernatant was loaded onto AG1-X8 resin to remove SO42-, Ni, Al, Na and some Mg using 8ml H2O and 3ml 2mol/L HCl. Cr was eluted by 2 mol/L HNO3 containing 5% H2O2 and the dried Cr was dissolved in 3% HNO3for isotopic analysis. The total yield to Cr is great than 80% even for samples with low Cr content. Chromium isotopes was measured on a Neptune plus MC-ICP-MS in China University of Geosciences(Beijing). Using our improved method, the δ53/52CrSRM979 values of USGS reference materials BHVO-2, BCR-2 and SGR-1b are -0.12±0.06‰(n=15), -0.09±0.06‰ (n=5), and 0.30±0.06‰ (n=12), respectively, which agree well with previously reported values. The δ53/52CrSRM979 of carbonaceous shale CP0-1 and CP0-12 collected from Hubei, China are 2.05

  8. Determination of plutonium isotopic abundances by gamma-ray spectrometry. Interim report on the status of methods and techniques developed by the Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Gunnink, R.

    1980-03-01

    This report presents an overview of methods and techniques developed by the Lawrence Livermore Laboratory for determining plutonium isotopic abundances from gamma-ray spectra that have been measured with germanium detectors. The methodology of fitting the spectral features includes discussions of algorithms for gamma-ray and x-ray peak shape fitting and generation of response spectra profiles characteristic of specific isotopes. Applications of the techniques developed at government, commercial, and Japanese reprocessing plants are described. Current development of the methodology for the nondestructive analysis of samples containing nondescript solid materials is also presented

  9. Proceedings of 1. international symposium on applied isotope geochemistry (AIG-1)

    International Nuclear Information System (INIS)

    Aaberg, G.; Joergensen, E.B.

    1993-09-01

    The publication is a compilation of abstracts from the ''1. international symposium on applied isotope geochemistry (AIG-1)'' in Norway. The symposium was the first of its kind taking up different applications of most of the available isotopic systems and thus covered a wide range of topics from: 1) Water resources, hydrology, geomedicine and environmental problems, 2) Petroleum exploration and production, 3) Mineral exploration and 4) Analytical methods

  10. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Isotope-dilution gas chromatography-mass spectrometry method for the analysis of hydroxyurea.

    Science.gov (United States)

    Garg, Uttam; Scott, David; Frazee, Clint; Kearns, Gregory; Neville, Kathleen

    2015-06-01

    Hydroxyurea is used in the treatment of various malignancies and sickle cell disease. There are limited studies on the pharmacokinetics of hydroxyurea, particularly in pediatric patients. An accurate, precise, and sensitive method is needed to support such studies and to monitor therapeutic adherence. We describe a novel gas chromatography-mass spectrometry (GC-MS) method for the determination of hydroxyurea concentration in plasma using stable labeled hydroxyurea C N2 as an internal standard. The method involved an organic extraction followed by the preparation of trimethylsilyl (TMS) derivatives of hydroxyurea for GC-MS selected ion-monitoring analysis. The following mass-to-charge (m/z) ratio ions for silated hydroxyurea and hydroxyurea C N2 were monitored: hydroxyurea-quantitative ion 277, qualifier ions 292 and 249; hydroxyurea C N2-quantitative ion 280, qualifier ion 295. This method was evaluated for reportable range, accuracy, within-run and between-run imprecisions, and limits of quantification. The reportable range for the method was 0.1-100 mcg/mL. All results were accurate within an allowable error of 15%. Within-run and between-run imprecisions were hydroxyurea described here is accurate, sensitive, precise, and robust. Its characteristics make the method suitable for supporting pharmacokinetic studies and/or clinical therapeutic monitoring.

  12. A new method for precise determination of iron, zinc and cadmium stable isotope ratios in seawater by double-spike mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Tim M., E-mail: conway.tm@gmail.com [Department of Earth and Ocean Sciences, University of South Carolina, Columbia, SC 29208 (United States); Rosenberg, Angela D. [Department of Earth and Ocean Sciences, University of South Carolina, Columbia, SC 29208 (United States); Adkins, Jess F. [California Institute of Technology, Division of Geological and Planetary Sciences, Pasadena, CA 91125 (United States); John, Seth G. [Department of Earth and Ocean Sciences, University of South Carolina, Columbia, SC 29208 (United States)

    2013-09-02

    Graphical abstract: ‘Metal-free’ seawater doped with varying concentrations of ‘zero’ isotope standards, processed through our simultaneous method, and then analyzed by double spike MC-ICPMS for Fe, Zn and Cd isotope ratios. All values were determined within 2 σ error (error bars shown) of zero. -- Highlights: •The first simultaneous method for isotopic analysis of Fe, Zn and Cd in seawater. •Designed for 1 L samples, a 1–20 fold improvement over previous methods. •Low blanks and high precision allow measurement of low concentration samples. •Small volume and fast processing are ideal for high-resolution large-scale studies. •Will facilitate investigation of marine trace-metal isotope cycling. -- Abstract: The study of Fe, Zn and Cd stable isotopes (δ{sup 56}Fe, δ{sup 66}Zn and δ{sup 114}Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal

  13. A new method for precise determination of iron, zinc and cadmium stable isotope ratios in seawater by double-spike mass spectrometry

    International Nuclear Information System (INIS)

    Conway, Tim M.; Rosenberg, Angela D.; Adkins, Jess F.; John, Seth G.

    2013-01-01

    Graphical abstract: ‘Metal-free’ seawater doped with varying concentrations of ‘zero’ isotope standards, processed through our simultaneous method, and then analyzed by double spike MC-ICPMS for Fe, Zn and Cd isotope ratios. All values were determined within 2 σ error (error bars shown) of zero. -- Highlights: •The first simultaneous method for isotopic analysis of Fe, Zn and Cd in seawater. •Designed for 1 L samples, a 1–20 fold improvement over previous methods. •Low blanks and high precision allow measurement of low concentration samples. •Small volume and fast processing are ideal for high-resolution large-scale studies. •Will facilitate investigation of marine trace-metal isotope cycling. -- Abstract: The study of Fe, Zn and Cd stable isotopes (δ 56 Fe, δ 66 Zn and δ 114 Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal for high

  14. The Case Study as a Method for Exploring Expert Music Teaching

    Directory of Open Access Journals (Sweden)

    Jane Saunders

    2010-05-01

    Full Text Available This article explains how the case study method was used in an exploration of the career of an expert music teacher. The contextual and holistic qualities of the case study are discussed. In addition, insider research and the situated knowledge of participants in this case study are considered, leading to a brief summary of the research findings and an explication of the expert music teacher.

  15. Bioinformatics: Cheap and robust method to explore biomaterial from Indonesia biodiversity

    Science.gov (United States)

    Widodo

    2015-02-01

    Indonesia has a huge amount of biodiversity, which may contain many biomaterials for pharmaceutical application. These resources potency should be explored to discover new drugs for human wealth. However, the bioactive screening using conventional methods is very expensive and time-consuming. Therefore, we developed a methodology for screening the potential of natural resources based on bioinformatics. The method is developed based on the fact that organisms in the same taxon will have similar genes, metabolism and secondary metabolites product. Then we employ bioinformatics to explore the potency of biomaterial from Indonesia biodiversity by comparing species with the well-known taxon containing the active compound through published paper or chemical database. Then we analyze drug-likeness, bioactivity and the target proteins of the active compound based on their molecular structure. The target protein was examined their interaction with other proteins in the cell to determine action mechanism of the active compounds in the cellular level, as well as to predict its side effects and toxicity. By using this method, we succeeded to screen anti-cancer, immunomodulators and anti-inflammation from Indonesia biodiversity. For example, we found anticancer from marine invertebrate by employing the method. The anti-cancer was explore based on the isolated compounds of marine invertebrate from published article and database, and then identified the protein target, followed by molecular pathway analysis. The data suggested that the active compound of the invertebrate able to kill cancer cell. Further, we collect and extract the active compound from the invertebrate, and then examined the activity on cancer cell (MCF7). The MTT result showed that the methanol extract of marine invertebrate was highly potent in killing MCF7 cells. Therefore, we concluded that bioinformatics is cheap and robust way to explore bioactive from Indonesia biodiversity for source of drug and another

  16. Labile pools of Pb in vegetable-growing soils investigated by an isotope dilution method and its influence on soil pH.

    Science.gov (United States)

    Xie, Hong; Huang, Zhi-Yong; Cao, Ying-Lan; Cai, Chao; Zeng, Xiang-Cheng; Li, Jian

    2012-08-01

    Pollution of Pb in the surface of agricultural soils is of increasing concern due to its serious impact on the plant growth and the human health through the food chain. However, the mobility, activity and bioavailability of Pb rely mainly on its various chemical species in soils. In the present study, E and L values, the labile pools of isotopically exchangeable Pb, were estimated using the method of isotope dilution in three vegetable-growing soils. The experiments involved adding a stable enriched isotope ((206)Pb > 96%) to a soil suspension and to soils in which plants are subsequently grown, the labile pools of Pb were then estimated by measuring the isotopic composition of Pb in soil solutions and in the plant tissues, respectively. In addition, the correlation of E values and soil pH was investigated at the ranges of pH 4.5-7.0. The amount of labile Pb in soils was also estimated using different single chemical extractants and a modified BCR approach. The results showed that after spiking the enriched isotopes of (206)Pb (>96%) for 24 hours an equilibration of isotopic exchanges in soil suspensions was achieved, and the isotope ratios of (208)Pb/(206)Pb measured at that time was used for calculating the E(24 h) values. The labile pools of Pb by %E(24 h) values, ranging from 53.2% to 61.7% with an average 57%, were found to be significantly higher (p soil pH was found in the tested soil sample. The results indicate that the %E(24 h) value can more rapidly and easily predict the labile pools of Pb in soils compared with L values, but it might be readily overestimated because of the artificial soil acidity derived from the spiked isotopic tracer and the excess of spiked enriched isotopes. The results also suggest that the amounts of Pb extracted with EDTA and the Σ(BCR) values extracted with the modified BCR approach are helpful to detect the labile pools of Pb in soils. In addition, the negative correlation between soil pH and the labile pools of Pb in soils

  17. Extended methods using thick-targets for nuclear reaction data of radioactive isotopes

    Science.gov (United States)

    Ebata, Shuichiro; Aikawa, Masayuki; Imai, Shotaro

    2017-09-01

    The nuclear transmutation is a technology to dispose of radioactive wastes. However, we do not have enough basic data for its developments, such as thick-target yields (TTY) and the interaction cross sections for radioactive material. We suggest two methods to estimate the TTY using inverse kinematics and to obtain the excitation function of the interaction cross sections which is named the thick-target transmission (T3) method. We deduce the energy-dependent conversion relation between the TTYs of the original system and its inverse kinematics, which can be replaced to a constant coefficient in the high energy region. Furthermore we show the usefulness of the T3 method to investigate the excitation function of the 12C + 27Al reaction in the simulation.

  18. Effects of cleaning methods upon preservation of stable isotopes and trace elements in shells of Cyprideis torosa (Crustacea, Ostracoda): Implications for palaeoenvironmental reconstruction

    Science.gov (United States)

    Roberts, L. R.; Holmes, J. A.; Leng, M. J.; Sloane, H. J.; Horne, D. J.

    2018-06-01

    The trace element (Sr/Ca and Mg/Ca) and stable isotope (δ18O and δ13C) geochemistry of fossil ostracod valves provide valuable information, particularly in lacustrine settings, on palaeo-water composition and palaeotemperature. The removal of sedimentary and organic contamination prior to geochemical analysis is essential to avoid bias of the results. Previous stable isotope and trace element work on ostracod shells has, however, employed different treatments for the removal of contamination beyond simple 'manual' cleaning using a paint brush and methanol under a low-power binocular microscope. For isotopic work pre-treatments include chemical oxidation, vacuum roasting and plasma ashing, and for trace element work sonication, chemical oxidation and reductive cleaning. The impact of different treatments on the geochemical composition of the valve calcite has not been evaluated in full, and a universal protocol has not been established. Here, a systematic investigation of the cleaning methods is undertaken using specimens of the ubiquitous euryhaline species, Cyprideis torosa. Cleaning methods are evaluated by undertaking paired analyses on a single carapace (comprising two valves); in modern ostracods, whose valves are assumed to be unaltered, the two valves should have identical geochemical and isotopic composition. Hence, when one valve is subjected to the chosen treatment and the other to simple manual cleaning any difference in composition can confidently be assigned to the treatment method. We show that certain cleaning methods have the potential to cause alteration to the geochemical signal, particularly Mg/Ca and δ18O, and hence have implications for palaeoenvironmental reconstructions. For trace-element determinations we recommend cleaning by sonication and for stable isotope analysis, oxidation by hydrogen peroxide. These methods remove contamination, yet do not significantly alter the geochemical signal.

  19. Determination of niobium in rocks by an isotope dilution spectrophotometric method

    Science.gov (United States)

    Greenland, L.P.; Campbell, E.Y.

    1970-01-01

    Rocks and minerals are fused with sodium peroxide in the presence of carrierfree 95Nb. The fusion cake is leached with water and the precipitate dissolved in hydrofluoric-sulfuric acid mixture. Niobium is extracted into methyl isobutyl ketone and further purified by ion exchange. The amount of niobium is determined spectrophotometrically with 4-(2-pyridylazo)-resorcinol, and the chemical yield of the separations determined by counting 95Nb. This procedure is faster and less sensitive to interferences than previously proposed methods for determining niobium in rocks.The high purity of the separated niobium makes the method applicable to nearly all matrices. ?? 1970.

  20. Analysis of the material's expenditure of electric contacts by means of the isotopic method

    International Nuclear Information System (INIS)

    Farkash, K.

    1979-01-01

    To investigate lifetime of the weak-current and heavy-current contacts different radioisotopic methods have been developed. Advantages of the radioisotopic methods as compared with other methods of testing consists of the fact that due to their sensitivity they permit to determine low expense of material; permit to determine quantitatively expense of each element separately from the elements, composing the contacts alloy; by means of these methods it is possible to evaluate quantitatively topological distribution of the matter separated from the contacts into the environment; it is possible to determine morphological characteristics of the matter separated from the contact. During investigation of the lifetime of contacts there were determined: value of the expense of the material of contacts; composition of the expense of the material of contacts; composition of the matter separated from the contact; distribution of the separated matter depending on the electrical parameters and number of the closings of contact in the case of different compositions of contacts and in different conditions. Strength of the contacts' alloys related to the electrical load was investigated at the special stand [ru

  1. A modified Gaussian integration method for thermal reaction rate calculation in U- and Pu-isotopes

    International Nuclear Information System (INIS)

    Bosevski, T.; Fredin, B.

    1966-01-01

    An advanced multi-group cell calculations a lot of data information is very often necessary, and hence the data administration will be elaborate, and the spectrum calculation will be time consuming. We think it is possible to reduce the necessary data information by using an effective reaction rate integration method well suited for U- and Pu-absorptions (author)

  2. Techniques for preparing isotopic targets

    International Nuclear Information System (INIS)

    Xu Guoji; Guan Shouren; Luo Xinghua; Sun Shuhua

    1987-12-01

    The techniques of making isotopic targets for nuclear physics experiments are introduced. Vacuum evaporation, electroplating, centrifugal precipitation, rolling and focused heavy-ion beam sputtering used to prepare various isotopic targets at IAE are described. Reduction-distillation with active metals and electrolytic reduction for converting isotope oxides to metals are mentioned. The stripping processes of producing self-supporting isotopic targets are summarized. The store methods of metallic targets are given

  3. Isotopic clusters

    International Nuclear Information System (INIS)

    Geraedts, J.M.P.

    1983-01-01

    Spectra of isotopically mixed clusters (dimers of SF 6 ) are calculated as well as transition frequencies. The result leads to speculations about the suitability of the laser-cluster fragmentation process for isotope separation. (Auth.)

  4. Stable isotope analysis of Dacryoconarid carbonate microfossils: a new tool for Devonian oxygen and carbon isotope stratigraphy.

    Science.gov (United States)

    Frappier, Amy Benoit; Lindemann, Richard H; Frappier, Brian R

    2015-04-30

    Dacryoconarids are extinct marine zooplankton known from abundant, globally distributed calcite microfossils in the Devonian, but their shell stable isotope composition has not been previously explored. Devonian stable isotope stratigraphy is currently limited to less common invertebrates or bulk rock analyses of uncertain provenance. As with Cenozoic planktonic foraminifera, isotopic analysis of dacryoconarid shells could facilitate higher-resolution, geographically widespread stable isotope records of paleoenvironmental change, including marine hypoxia events, climate changes, and biocrises. We explored the use of Dacryoconarid isotope stratigraphy as a viable method in interpreting paleoenvironments. We applied an established method for determining stable isotope ratios (δ(13) C, δ(18) O values) of small carbonate microfossils to very well-preserved dacryoconarid shells. We analyzed individual calcite shells representing five common genera using a Kiel carbonate device coupled to a MAT 253 isotope ratio mass spectrometer. Calcite shell δ(13) C and δ(18) O values were compared by taxonomic group, rock unit, and locality. Single dacryoconarid calcite shells are suitable for stable isotope analysis using a Kiel-IRMS setup. The dacryoconarid shell δ(13) C values (-4.7 to 2.3‰) and δ(18) O values (-10.3 to -4.8‰) were consistent across taxa, independent of shell size or part, but varied systematically through time. Lower fossil δ(18) O values were associated with warmer water temperature and more variable δ(13) C values were associated with major bioevents. Dacryoconarid δ(13) C and δ(18) O values differed from bulk rock carbonate values. Dacryoconarid individual microfossil δ(13) C and δ(18) O values are highly sensitive to paleoenvironmental changes, thus providing a promising avenue for stable isotope chemostratigraphy to better resolve regional to global paleoceanographic changes throughout the upper Silurian to the upper Devonian. Our results

  5. Stable isotopes

    International Nuclear Information System (INIS)

    Evans, D.K.

    1986-01-01

    Seventy-five percent of the world's stable isotope supply comes from one producer, Oak Ridge Nuclear Laboratory (ORNL) in the US. Canadian concern is that foreign needs will be met only after domestic needs, thus creating a shortage of stable isotopes in Canada. This article describes the present situation in Canada (availability and cost) of stable isotopes, the isotope enrichment techniques, and related research programs at Chalk River Nuclear Laboratories (CRNL)

  6. New method of radiation measurement at carbon isotope 14 low level in an environmental atmospheric sampling

    International Nuclear Information System (INIS)

    Tormos, J.

    2009-01-01

    A new method of preparation is proposed to extract the atmospheric carbon trapped in the solution of soda coming from air sampling in environment with a carbon-14 bubbler (type H.A.G. 7000). It is based on the neutralisation of the global soda solution got from bubbling pots by nitric acid, the complete desorption of the carbon under gaseous oxidized form (CO 2 ) and its trapping in a only capacity containing a reactive. The whole of the device is scanned by air at steady rate. A test catch of the reactive and of the trapped carbon dioxide is then blended to a glistening liquid (Permafluor E+) and measured in beta counting by scintillation in liquid medium with a counter for the measurement of low energy beta emitters at very low level of activity (Quantulus type). this method allows to get a limit of detection equal to 5 mBq/m 3 for the atmospheric organic carbon. The principal interest of this method is its quickness and simplicity of setting in motion for a measurement of 14 C in the atmospheric carbon dioxide at a level of natural activity. (N.C.)

  7. Optimization of the solvent-based dissolution method to sample volatile organic compound vapors for compound-specific isotope analysis.

    Science.gov (United States)

    Bouchard, Daniel; Wanner, Philipp; Luo, Hong; McLoughlin, Patrick W; Henderson, James K; Pirkle, Robert J; Hunkeler, Daniel

    2017-10-20

    The methodology of the solvent-based dissolution method used to sample gas phase volatile organic compounds (VOC) for compound-specific isotope analysis (CSIA) was optimized to lower the method detection limits for TCE and benzene. The sampling methodology previously evaluated by [1] consists in pulling the air through a solvent to dissolve and accumulate the gaseous VOC. After the sampling process, the solvent can then be treated similarly as groundwater samples to perform routine CSIA by diluting an aliquot of the solvent into water to reach the required concentration of the targeted contaminant. Among solvents tested, tetraethylene glycol dimethyl ether (TGDE) showed the best aptitude for the method. TGDE has a great affinity with TCE and benzene, hence efficiently dissolving the compounds during their transition through the solvent. The method detection limit for TCE (5±1μg/m 3 ) and benzene (1.7±0.5μg/m 3 ) is lower when using TGDE compared to methanol, which was previously used (385μg/m 3 for TCE and 130μg/m 3 for benzene) [2]. The method detection limit refers to the minimal gas phase concentration in ambient air required to load sufficient VOC mass into TGDE to perform δ 13 C analysis. Due to a different analytical procedure, the method detection limit associated with δ 37 Cl analysis was found to be 156±6μg/m 3 for TCE. Furthermore, the experimental results validated the relationship between the gas phase TCE and the progressive accumulation of dissolved TCE in the solvent during the sampling process. Accordingly, based on the air-solvent partitioning coefficient, the sampling methodology (e.g. sampling rate, sampling duration, amount of solvent) and the final TCE concentration in the solvent, the concentration of TCE in the gas phase prevailing during the sampling event can be determined. Moreover, the possibility to analyse for TCE concentration in the solvent after sampling (or other targeted VOCs) allows the field deployment of the sampling

  8. Isotopic techniques in radioactive waste disposal site evaluation: a method for reducing uncertainties I. T, T/3He, 4He, 14C, 36Cl

    International Nuclear Information System (INIS)

    Muller, A.B.

    1981-01-01

    This paper introduces five of the isotopic techniques which can help reduce uncertainties associated with the assessment of radioactive waste disposal sites. The basic principles and practical considerations of these best known techniques have been presented, showing how much additional site specific information can be acquired at little cost or consequence to containment efficiency. These methods, and the more experimental methods appearing in the figure but not discussed here, should be considered in any detailed site characterization, data collection and analysis

  9. Development of a versatile sample preparation method and its application for rare-earth pattern and Nd isotope ratio analysis in nuclear forensics

    International Nuclear Information System (INIS)

    Krajko, J.

    2015-01-01

    An improved sample preparation procedure for trace-levels of lanthanides in uranium-bearing samples was developed. The method involves a simple co-precipitation using Fe(III) carrier in ammonium carbonate medium to remove the uranium matrix. The procedure is an effective initial pre-concentration step for the subsequent extraction chromatographic separations. The applicability of the method was demonstrated by the measurement of REE pattern and 143 Nd/ 144 Nd isotope ratio in uranium ore concentrate samples. (author)

  10. Comparison between IRMS and CRDS methods in the determination of isotopic ratios 2H/1H and 18O/16O in water

    International Nuclear Information System (INIS)

    Santos, T. H. R.; Zucchi, M. R.; Lemaire, T.; Azevedo, A. E. G.

    2013-01-01

    Traditionally, the method used for measuring the isotope ratios is the Isotope Ratio Mass Spectrometers (IRMS). A new method has been used to determine the isotopic abundances, the Cavity Ring-Down Spectroscopy (CRDS). It consists of a technique of direct absorption, of high sensitivity, which is based on measuring the absorption ratio, as a function of time, of the light confined in a high finesse optical cavity, instead of the magnitude of light beam absorption. The values of 18 O/ 16 O and D/H ratios are determined with respect to international standards VSMOW, GISP and SLAP from the International Atomic Energy Agency (IAEA). In this work, the IRMS and CRDS techniques are compared, verifying that the CRDS technique is promising and has some advantages compared to IRMS. It uses a smaller amount of sample, the isotope measurements are made simultaneously from the steam, reducing the analysis time. It also shows good reproducibility and accuracy, and it does not require a preliminary sample preparation.

  11. High-precision quadruple isotope dilution method for simultaneous determination of nitrite and nitrate in seawater by GCMS after derivatization with triethyloxonium tetrafluoroborate

    Energy Technology Data Exchange (ETDEWEB)

    Pagliano, Enea, E-mail: enea.pagliano@nrc-cnrc.gc.ca; Meija, Juris; Mester, Zoltán

    2014-05-01

    Highlights: • High-precision determination of nitrite and nitrate in seawater. • Use of quadruple isotope dilution. • Aqueous Et₃O⁺BF₄]⁻ derivatization chemistry for GCMS analysis of nitrite and nitrate. Abstract: Quadruple isotope dilution mass spectrometry (ID⁴MS) has been applied for simultaneous determination of nitrite and nitrate in seawater. ID⁴MS allows high-precision measurements and entails the use of isotopic internal standards (¹⁸O-nitrite and ¹⁵N-nitrate). We include a tutorial on ID⁴MS outlining optimal experimental design which generates results with low uncertainties and obviates the need for direct (separate) evaluation of the procedural blank. Nitrite and nitrate detection was achieved using a headspace GCMS procedure based on single-step aqueous derivatization with triethyloxonium tetrafluoroborate at room temperature. In this paper the sample preparation was revised and fundamental aspects of this chemistry are presented. The proposed method has detection limits in the low parts-per-billion for both analytes, is reliable, precise, and has been validated using a seawater certified reference material (MOOS-2). Simplicity of the experimental design, low detection limits, and the use of quadruple isotope dilution makes the present method superior to the state-of-the-art for determination of nitrite and nitrate, and an ideal candidate for reference measurements of these analytes in seawater.

  12. An isotope approach based on C-13 pulse-chase labelling vs. the root trenching method to separate heterotrophic and autotrophic respiration in cultivated peatlands

    Energy Technology Data Exchange (ETDEWEB)

    Biasi, C.; Pitkamaki, A. S.; Tavi, N. M.; Koponen, H. T.; Martikainen, P. J. [Univ.of Eastern Finland, Kuopio (Finland). Dept. of Environmental Science], e-mail: christina.biasi@uef.fi

    2012-11-01

    We tested an isotope method based on C-13 pulse-chase labelling for determining the fractional contribution of soil microbial respiration to overall soil respiration in an organic soil (cutaway peatland, eastern Finland), cultivated with the bioenergy crop, reed canary grass. The plants were exposed to CO{sub 2}-13 for five hours and the label was thereafter determined in CO{sub 2} derived from the soil-root system. A two-pool isotope mixing model was used to separate sources of respiration. The isotopic approach showed that a minimum of 50% of the total CO{sub 2} originated from soil-microbial respiration. Even though the method uses undisturbed soil-plant systems, it has limitations concerning the experimental determination of the true isotopic signal of all components contributing to autotrophic respiration. A trenching experiment which was comparatively conducted resulted in a 71% fractional contribution of soil-microbial respiration. This value was likely overestimated. Further studies are needed to evaluate critically the output from these two partitioning approaches. (orig.)

  13. Evaluation of the recycle of nitrogen in a succession bean - corn -bean By means of the isotopic method

    International Nuclear Information System (INIS)

    Duennas Graciela; Munniz, Olegario; Sanchez, Tamara; Gomez, Luis

    1999-01-01

    To determine the recycle of Nitrogen in a succession bean - corn - bean a was developed I experience under field conditions, on Red Ferralitic soils (Rhodic Ferrasols) with the one I use of the stable isotope 15 Nitrogen

  14. Fractional Absorption of Active Absorbable Algal Calcium (AAACa and Calcium Carbonate Measured by a Dual Stable-Isotope Method

    Directory of Open Access Journals (Sweden)

    Steven A. Abrams

    2010-07-01

    Full Text Available With the use of stable isotopes, this study aimed to compare the bioavailability of active absorbable algal calcium (AAACa, obtained from oyster shell powder heated to a high temperature, with an additional heated seaweed component (Heated Algal Ingredient, HAI, with that of calcium carbonate. In 10 postmenopausal women volunteers aged 59 to 77 years (mean ± S.D., 67 ± 5.3, the fractional calcium absorption of AAACa and CaCO3 was measured by a dual stable isotope method. 44Ca-enriched CaCO3 and AAACa were administered in all subjects one month apart. After a fixed-menu breakfast and pre-test urine collection (Urine 0, 42Ca-enriched CaCl2 was intravenously injected, followed by oral administration of 44Ca-enriched CaCO3 without carrier 15 minutes later, and complete urine collection for the next 24 hours (Urine 24. The fractional calcium absorption was calculated as the ratio of Augmentation of 44Ca from Urine 0 to Urine 24/ augmentation of 42Ca from Urine 0 to Urine 24. Differences and changes of 44Ca and 42Ca were corrected by comparing each with 43Ca. Fractional absorption of AAACa (mean ± S.D., 23.1 ± 6.4, was distinctly and significantly higher than that of CaCO3 (14.7 ± 6.4; p = 0.0060 by paired t-test. The mean fractional absorption was approximately 1.57-times higher for AAACa than for CaCO3. The serum 25(OH vitamin D level was low (mean ± S.D., 14.2 ± 4.95 ng/ml, as is common in this age group in Japan. Among the parameters of the bone and mineral metabolism measured, none displayed a significant correlation with the fractional absorption of CaCO3 and AAACa. Higher fractional absorption of AAACa compared with CaCO3 supports previous reports on the more beneficial effect of AAACa than CaCO3 for osteoporosis.

  15. Phenylalanine isotope pulse method to measure effect of sepsis on protein breakdown and membrane transport in the pig.

    Science.gov (United States)

    Ten Have, Gabriella A M; Engelen, Mariëlle P K J; Wolfe, Robert R; Deutz, Nicolaas E P

    2017-06-01

    The primed-continuous (PC) phenylalanine (Phe) stable isotope infusion methodology is often used as a proxy for measuring whole body protein breakdown (WbPB) in sepsis. It is unclear if WbPB data obtained by an easy-to-use single IV Phe isotope pulse administration (PULSE) are comparable to those by PC. Compartmental modeling with PULSE could provide us more insight in WbPB in sepsis. Therefore, in the present study, we compared PULSE with PC as proxy for WbPB in an instrumented pig model with Pseudomonas aeruginosa- induced severe sepsis (Healthy: n = 9; Sepsis: n = 13). Seventeen hours after sepsis induction, we compared the Wb rate of appearance (WbR a ) of Phe obtained by PC (L-[ ring - 13 C 6 ]Phe) and PULSE (L-[ 15 N]Phe) in arterial plasma using LC-MS/MS and (non)compartm e ntal modeling. PULSE-WbR a was highly correlated with PC-WbR a ( r  = 0.732, P sepsis (Healthy: 3,378 ± 103; Sepsis: 4,333 ± 160 nmol·kg BW -1 ·min -1 , P = 0.0002). With PULSE, sepsis was characterized by an increase of the metabolic shunting (Healthy: 3,021 ± 347; Sepsis: 4,233 ± 344 nmol·kg BW -1 ·min -1 , P = 0.026). Membrane transport capacity was the same. Both PC and PULSE methods are able to assess changes in WbR a of plasma Phe reflecting WbPB changes with high sensitivity, independent of the (patho)physiological state. The easy-to-use (non)compartmental PULSE reflects better the real WbPB than PC. With PULSE compartmental analysis, we conclude that the membrane transport capacity for amino acids is not compromised in severe sepsis. Copyright © 2017 the American Physiological Society.

  16. Direct methods and residue type specific isotope labeling in NMR structure determination and model-driven sequential assignment

    International Nuclear Information System (INIS)

    Schedlbauer, Andreas; Auer, Renate; Ledolter, Karin; Tollinger, Martin; Kloiber, Karin; Lichtenecker, Roman; Ruedisser, Simon; Hommel, Ulrich; Schmid, Walther; Konrat, Robert; Kontaxis, Georg

    2008-01-01

    Direct methods in NMR based structure determination start from an unassigned ensemble of unconnected gaseous hydrogen atoms. Under favorable conditions they can produce low resolution structures of proteins. Usually a prohibitively large number of NOEs is required, to solve a protein structure ab-initio, but even with a much smaller set of distance restraints low resolution models can be obtained which resemble a protein fold. One problem is that at such low resolution and in the absence of a force field it is impossible to distinguish the correct protein fold from its mirror image. In a hybrid approach these ambiguous models have the potential to aid in the process of sequential backbone chemical shift assignment when 13 C β and 13 C' shifts are not available for sensitivity reasons. Regardless of the overall fold they enhance the information content of the NOE spectra. These, combined with residue specific labeling and minimal triple-resonance data using 13 C α connectivity can provide almost complete sequential assignment. Strategies for residue type specific labeling with customized isotope labeling patterns are of great advantage in this context. Furthermore, this approach is to some extent error-tolerant with respect to data incompleteness, limited precision of the peak picking, and structural errors caused by misassignment of NOEs

  17. Isotope nephrography in the assessment of different methods of surgical repair of the kidney after blunt lesions of intermediate degree

    International Nuclear Information System (INIS)

    Hoeflin, F.G.; Schoenenberger, A.; Mettler, D.; Roesler, H.; Zimmermann, A.; Bilweis, J.; Zingg, E.

    1986-01-01

    Despite recent improvements in diagnostic facilities there are no clear guidelines for the management of intermediate degree blunt renal trauma. Sixteen experimentally induced blunt renal lesions in pigs were treated either with a new alloplastic renal capsule made to our specifications of semi-elastic Vicryl mesh or with homologous pig fibrin sealant of with through-and-through chromic catgut sutures. Postoperative renal function was repeatedly assessed in all animals by isotope renography using 123 I-hippuric acid. Results: At surgery the Vicryl mesh was easily and quickly applied. The two other procedures were technically more demanding and time-consuming. Full haemostasis was obtained with all three methods. Kidneys which had been repaired with the Vicryl mesh contained considerably less scar tissue at the site of parenchymal rupture and showed neither perirenal fibrosis nor atrophy of the parenchyma in the vicintiy of the capsule. In a first net version, where high initial tension was applied, final clearance was significantly lower than in the other groups, due to an initial transient ischemic period. A modified technique with a second, final net version allowing controlled expansion of the kidneys during the postoperative period resulted in optimal late results. (Author)

  18. Study on kinetic degradation in soil and horizontal transfer of bt gene by 35S isotopic tracing method

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhang Yanfei; Ye Qingfu

    2012-01-01

    In this study, 35 S isotopic tracing method was applied to investigate kinetic degradation of bt gene from Bt transgenic rice TT51 in two different soil and possibility of its horizontal transfer into soil bacteria as well. Results showed that, during 30 d of aerobic incubation, it was indicated that 35 S-Bt gene was not horizontally transferred into soil microorganisms. The aerobic soil degradation dynamics significantly followed a first-order dissipation pattern for bt gene. After 30 d of incubation, the amount of bt gene reached 9.32% of applied radioactivity for the fluvio-marine yellow loamy soil and 9.92% for the fluvio-aquatic soil, respectively. The half-lives in two soils were 3.53 d for the former soil and 5. 77 d for the latter soil, which means that bt gene was more easily degradable in the weak acidic soil. The use of 35 S labeling proved to be valuable; it served the purpose of validating the rigorousness of experimental protocols, and provided insights into the soil environmental safety assessment for Bt transgenic rice. (authors)

  19. The effect of different levels of fertilizer on nitrogen nutrient of pasture using 15N-isotope dilution method

    International Nuclear Information System (INIS)

    Wei Dongpu; Bai Lingyu; Hua Luo; Yao Yunyin

    2000-01-01

    A pot experiment was carried out to study the effect of different levels of fertilizer on N% of ryegrass in monoculture or mixed culture with white clover and symbiotic dinitrogen fixation of white clover by using 15 N-isotope dilution method. It showed that (1) N% of ryegrass in monoculture or mixed culture was the highest at 67 days after fertilizing (DAF) and decreased with time; (2) N% of white clover was the greatest at 67 DAF, slightly decreased at 92 DAF, and then increased at 137 DAF, related to the increasing of nitrogen fixation by white clover; (3) At 164 kg 15 NH 4 SO 4 /hm 2 , N% of ryegrass in mixed culture at different cutting time was greater than that in monoculture. It obviously occurred that fixed nitrogen was transferred from white clover to ryegrass in mixed; (4) During the whole growth period, the main nitrogen resource of white clover was symbiotic dinitrogen fixation and that of ryegrass was soil nitrogen; (5) Effect of different levels of applied N on N% of ryegrass and white clover was significant

  20. Automated method for simultaneous lead and strontium isotopic analysis applied to rainwater samples and airborne particulate filters (PM10).

    Science.gov (United States)

    Beltrán, Blanca; Avivar, Jessica; Mola, Montserrat; Ferrer, Laura; Cerdà, Víctor; Leal, Luz O

    2013-09-03

    A new automated, sensitive, and fast system for the simultaneous online isolation and preconcentration of lead and strontium by sorption on a microcolumn packed with Sr-resin using an inductively coupled plasma mass spectrometry (ICP-MS) detector was developed, hyphenating lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA). Pb and Sr are directly retained on the sorbent column and eluted with a solution of 0.05 mol L(-1) ammonium oxalate. The detection limits achieved were 0.04 ng for lead and 0.03 ng for strontium. Mass calibration curves were used since the proposed system allows the use of different sample volumes for preconcentration. Mass linear working ranges were between 0.13 and 50 ng and 0.1 and 50 ng for lead and strontium, respectively. The repeatability of the method, expressed as RSD, was 2.1% and 2.7% for Pb and Sr, respectively. Environmental samples such as rainwater and airborne particulate (PM10) filters as well as a certified reference material SLRS-4 (river water) were satisfactorily analyzed obtaining recoveries between 90 and 110% for both elements. The main features of the LOV-MSFIA-ICP-MS system proposed are the capability to renew solid phase extraction at will in a fully automated way, the remarkable stability of the column which can be reused up to 160 times, and the potential to perform isotopic analysis.