WorldWideScience

Sample records for isotope dilution sector-field

  1. Isotope dilution analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fudge, A.

    1978-12-15

    The following aspects of isotope dilution analysis are covered in this report: fundamental aspects of the technique; elements of interest in the nuclear field, choice and standardization of spike nuclide; pre-treatment to achieve isotopic exchange and chemical separation; sensitivity; selectivity; and accuracy.

  2. Determination of trace sulfur in biodiesel and diesel standard reference materials by isotope dilution sector field inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amais, Renata S. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Long, Stephen E. [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States); Nóbrega, Joaquim A. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Christopher, Steven J., E-mail: steven.christopher@nist.gov [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States)

    2014-01-02

    Graphical abstract: -- Highlights: •Sulfur mass fractions are measured below 10 mg kg{sup −1} in diesel fuel materials. •SF-ICP-MS resolves molecular interferences, including oxygen and sulfur hydrides. •A detection limit of 0.7 mg kg{sup −1} (in the fuel sample) was obtained. -- Abstract: A method is described for quantification of sulfur at low concentrations on the order of mg kg{sup −1} in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at {sup 32}S and {sup 34}S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg{sup −1} S and 2.5 mg kg{sup −1} S (in the sample). The LOD was constrained by instrument background counts at {sup 32}S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg{sup −1}. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.

  3. Field ionization mass spectrometry (FIMS) applied to tracer studies and isotope dilution analysis

    International Nuclear Information System (INIS)

    Anbar, M.; Heck, H.d'A.; McReynolds, J.H.; St John, G.A.

    1975-01-01

    The nonfragmenting nature of field ionization mass spectrometry makes it a preferred technique for the isotopic analysis of multilabeled organic compounds. The possibility of field ionization of nonvolatile thermolabile materials significantly extends the potential uses of this technique beyond those of conventional ionization methods. Multilabeled tracers may be studied in biological systems with a sensitivity comparable to that of radioactive tracers. Isotope dilution analysis may be performed reliably by this technique down to picogram levels. These techniques will be illustrated by a number of current studies using multilabeled metabolites and drugs. The scope and limitations of the methodology are discussed

  4. Gluconeogenesis from labeled carbon: estimating isotope dilution

    International Nuclear Information System (INIS)

    Kelleher, J.K.

    1986-01-01

    To estimate the rate of gluconeogenesis from steady-state incorporation of labeled 3-carbon precursors into glucose, isotope dilution must be considered so that the rate of labeling of glucose can be quantitatively converted to the rate of gluconeogenesis. An expression for the value of this isotope dilution can be derived using mathematical techniques and a model of the tricarboxylic acid (TCA) cycle. The present investigation employs a more complex model than that used in previous studies. This model includes the following pathways that may affect the correction for isotope dilution: 1) flux of 3-carbon precursor to the oxaloacetate pool via acetyl-CoA and the TCA cycle; 2) flux of 4- or 5-carbon compounds into the TCA cycle; 3) reversible flux between oxaloacetate (OAA) and pyruvate and between OAA and fumarate; 4) incomplete equilibrium between OAA pools; and 5) isotope dilution of 3-carbon tracers between the experimentally measured pool and the precursor for the TCA-cycle OAA pool. Experimental tests are outlined which investigators can use to determine whether these pathways are significant in a specific steady-state system. The study indicated that flux through these five pathways can significantly affect the correction for isotope dilution. To correct for the effects of these pathways an alternative method for calculating isotope dilution is proposed using citrate to relate the specific activities of acetyl-CoA and OAA

  5. Multi-element isotope dilution analyses using ICP-MS

    International Nuclear Information System (INIS)

    Volpe, A.M.

    1996-01-01

    Presently, 37 elements ranging from light (Li,B) through transition metals, noble, rare earth and heavy elements, to actinides and transuranics (Pu, Am, Cm) are measured by isotope dilution at Lawrence Livermore National Laboratory. Projects range from geological and hydrological to biological. The research goal is to measure accurately many elements present in diverse matrices at trace (ppb) levels using isotope dilution methods. Major advantages of isotope dilution methods are accuracy, elimination of ion intensity calibration, and quantitation for samples that require chemical separation. Accuracy depends on tracer isotope calibration, tracer-sample isotopic equilibration, and appropriate background, isobaric and mass bias corrections. Propagation of isotope ratio error due to improper tracer isotope addition is a major concern with multi-element analyses when abundances vary widely. 11 refs., 3 figs

  6. Plutonium determination by isotope dilution

    International Nuclear Information System (INIS)

    Lucas, M.

    1980-01-01

    The principle is to add to a known amount of the analysed solution a known amount of a spike solution consisting of plutonium 242. The isotopic composition of the resulting mixture is then determined by surface ionization mass spectrometry, and the plutonium concentration in the solution is deduced, from this measurement. For irradiated fuels neutronic studies or for fissile materials balance measurements, requiring the knowledge of the ratio U/Pu or of concentration both uranium and plutonium, it is better to use the double spike isotope dilution method, with a spike solution of known 233 U- 242 Pu ratio. Using this method, the ratio of uranium to plutonium concentration in the irradiated fuel solution can be determined without any accurate measurement of the mixed amounts of sample and spike solutions. For fissile material balance measurements, the uranium concentration is determined by using single isotope dilution, and the plutonium concentration is deduced from the ratio Pu/U and U concentration. The main advantages of isotope dilution are its selectivity, accuracy and very high sensitivity. The recent improvements made to surface ionization mass spectrometers have considerably increased the precision of the measurements; a relative precision of about 0.2% to 0.3% is obtained currently, but it could be reduced to 0.1%, in the future, with a careful control of the experimental procedures. The detection limite is around 0.1 ppb [fr

  7. Paradigms in isotope dilution mass spectrometry for elemental speciation analysis

    International Nuclear Information System (INIS)

    Meija, Juris; Mester, Zoltan

    2008-01-01

    Isotope dilution mass spectrometry currently stands out as the method providing results with unchallenged precision and accuracy in elemental speciation. However, recent history of isotope dilution mass spectrometry has shown that the extent to which this primary ratio measurement method can deliver accurate results is still subject of active research. In this review, we will summarize the fundamental prerequisites behind isotope dilution mass spectrometry and discuss their practical limits of validity and effects on the accuracy of the obtained results. This review is not to be viewed as a critique of isotope dilution; rather its purpose is to highlight the lesser studied aspects that will ensure and elevate current supremacy of the results obtained from this method

  8. A theory of stable-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Pickup, J.F.; McPherson, C.K.

    1977-01-01

    In order to perform quantitative analysis using stable isotope dilution with mass spectrometry, an equation is derived which describes the relationship between the relative proportions of natural and labelled material and measured isotope ratios

  9. Further development of IDGS: Isotope dilution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Li, T.K.; Parker, J.L.; Kuno, Y.; Sato, S.; Kamata, M.; Akiyama, T.

    1991-01-01

    The isotope dilution gamma-ray spectrometry (IDGS) technique for determining the plutonium concentration and isotopic composition of highly radioactive spent-fuel dissolver solutions has been further developed. Both the sample preparation and the analysis have been improved. The plutonium isotopic analysis is based on high-resolution, low-energy gamma-ray spectrometry. The plutonium concentration in the dissolver solutions then is calculated from the measured isotopic differences among the spike, the dissolver solution, and the spiked dissolver solution. Plutonium concentrations and isotopic compositions of dissolver solutions analyzed from this study agree well with those obtained by traditional isotope dilution mass spectrometry (IDMS) and are consistent with the first IDGS experimental result. With the current detector efficiency, sample size, and a 100-min count time, the estimated precision is ∼0.5% for 239 Pu and 240 Pu isotopic analyses and ∼1% for the plutonium concentration analysis. 5 refs., 2 figs., 7 tabs

  10. Isotopic dilution requirements for 233U criticality safety in processing and disposal facilities

    International Nuclear Information System (INIS)

    Elam, K.R.; Forsberg, C.W.; Hopper, C.M.; Wright, R.Q.

    1997-11-01

    The disposal of excess 233 U as waste is being considered. Because 233 U is a fissile material, one of the key requirements for processing 233 U to a final waste form and disposing of it is to avoid nuclear criticality. For many processing and disposal options, isotopic dilution is the most feasible and preferred option to avoid nuclear criticality. Isotopic dilution is dilution of fissile 233 U with nonfissile 238 U. The use of isotopic dilution removes any need to control nuclear criticality in process or disposal facilities through geometry or chemical composition. Isotopic dilution allows the use of existing waste management facilities, that are not designed for significant quantities of fissile materials, to be used for processing and disposing of 233 U. The amount of isotopic dilution required to reduce criticality concerns to reasonable levels was determined in this study to be ∼ 0.66 wt% 233 U. The numerical calculations used to define this limit consisted of a homogeneous system of silicon dioxide (SiO 2 ), water (H 2 O), 233 U, and depleted uranium (DU) in which the ratio of each component was varied to determine the conditions of maximum nuclear reactivity. About 188 parts of DU (0.2 wt% 235 U) are required to dilute 1 part of 233 U to this limit in a water-moderated system with no SiO 2 present. Thus, for the US inventory of 233 U, several hundred metric tons of DU would be required for isotopic dilution

  11. Guideline on Isotope Dilution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Amy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-19

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. This method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.

  12. Comparative determination of sucrose content in sugar beet by polarimetric and isotope dilution methods

    Energy Technology Data Exchange (ETDEWEB)

    Malec, K; Szuchnik, A [Institute of Nuclear Research, Warsaw (Poland); Rydel, S; Walerianaczyk, E [Instytut Przemyslu Cukrowniczego, Warsaw (Poland)

    1976-01-01

    The comparative determination of sucrose content in sugar beets has been investigated by following methods: polarimetric, direct isotope dilution and double carrier-isotope dilution analysis. Basing upon the obtained results it has been ascertained, that in the case of worse quality beets the polarimetric determinations differ greatly from isotopic data.

  13. The Influence of Seed-borne N in 15N Isotope Dilution Studies with Legumes The Influence of Seed-borne N in 15N Isotope Dilution Studies with Legumes

    DEFF Research Database (Denmark)

    Jensen, Erik Steen; Andersen, A. J.; Thomsen, J. D.

    1985-01-01

    The distriution of seed-borne N in shoot and root of pea and field bean was studied using three methods: 1) determination of the N content in shoot and root of plants grown in sand culture without other N sources. 2) 15N isotope dilution in plants grown in Rhizobium-free medium supplied with 15N-...... of corrections for seed-borne N in studies of nitrogen fixation in legumes is discussed....

  14. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  15. Isotope dilution mass spectrometry: some present limitations and possibilities to overcome these

    International Nuclear Information System (INIS)

    De Bievre, P.

    1981-01-01

    Thermionic mass spectrometry still has great potential for more precise and accurate measurements but it is going to place tremendous requirements on (1) the chemical purity of the samples we measure, (2) the temperature of both ionization and the filaments and (3) the number of molecular species being handled in ion sources which could increase to several dozen for one type of isotopic analysis. The lack of control by mass spectrometrists over the chemical preparation of the samples for isotopic analysis is an inherent limitation to further improvement of isotope dilution mass spectrometry. A limiting factor in isotope dilution is the ability to measure the ratio. At present, uranium isotopic reference materials are 0.1% and recently one was prepared at 0.05%. As these serve to calibrate isotope ratio measurements one cannot do better than these valves. There is no way in which isotope dilution can be improved until these reference values improve. For plutonium there are not even absolute isotope ratio standards. An agreement has been established between CBNM, Geel and the National Bureau of Standards, Washington, to prepare isotope ratio reference materials jointly so that they will be common to both communities. It is recommended that common batches of reference be established and stored at several places to guarantee accessibility at all times

  16. Determination of zinc stable isotopes in biological materials using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Patterson, K.Y.; Veillon, Claude

    1992-01-01

    A method is described for using isotope dilution to determine both the amount of natural zinc and enriched isotopes of zinc in biological samples. Isotope dilution inductively coupled plasma mass spectrometry offers a way to quantify not only the natural zinc found in a sample but also the enriched isotope tracers of zinc. Accurate values for the enriched isotopes and natural zinc are obtained by adjusting the mass count rate data for measurable instrumental biases. Analytical interferences from the matrix are avoided by extracting the zinc from the sample matrix using diethylammonium diethyldithiocarbamate. The extraction technique separates the zinc from elements which form interfering molecular ions at the same nominal masses as the zinc isotopes. Accuracy of the method is verified using standard reference materials. The detection limit is 0.06 μg Zn per sample. Precision of the abundance ratios range from 0.3-0.8%. R.S.D. for natural zinc concentrations is about 200-600 μg g -1 . The accuracy and precision of the measurements make it possible to follow enriched isotopic tracers of zinc in biological samples in metabolic tracer studies. (author). 19 refs.; 1 fig., 4 tabs

  17. Hot vacuum extraction-isotopic dilution mass spectrometry for determination of hydrogen isotopes in zircaloys

    International Nuclear Information System (INIS)

    Shi, Y.; Leeson, P.K.; Wilkin, D.; Britton, A.; Macleod, R.

    2016-01-01

    A hot vacuum extraction-isotope dilution mass spectrometry (HVE-IDMS) was studied for determination of hydrogen isotopes in zirconium metal and alloys as nuclear reactor materials. A theoretical assessment of the completeness of the extraction of hydrogen isotopes under the chosen condition was carried out based on the hydrogen and deuterium solubility data for zirconium. The optimal isotopic spiking condition for conventional IDMS was further explored for the special case IDMS where the isotope abundance of the samples is varied and non-natural. Applying the optimal conditions, the accurate IDMS determination was realized. The agreement between the measured values and the certified or prepared values of standard reference materials and homemade standard materials validate the method developed. (author)

  18. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  19. Theoretical implications for the estimation of dinitrogen fixation by large perennial plant species using isotope dilution

    Science.gov (United States)

    Dwight D. Baker; Maurice Fried; John A. Parrotta

    1995-01-01

    Estimation of symbiotic N2 fixation associated with large perennial plant species, especially trees, poses special problems because the process must be followed over a potentially long period of time to integrate the total amount of fixation. Estimations using isotope dilution methodology have begun to be used for trees in field studies. Because...

  20. Water Metabolism of Walruses by Isotope Dilution

    DEFF Research Database (Denmark)

    Acquarone, M.; Born, E. W.; Chwalibog, A.

    was sampled via an epidural catheter, at regular intervals, for up to seven hours after the initial enrichment to assess isotope equilibration in the body water pools. Five individuals returned to the haul-out after feeding trips of varying duration (158±86 hr, 44-287 hr) where they were immobilized again......In August 2000, the hydrogen isotope dilution method was used on 7 adult male Atlantic walruses (Odobenus rosmarus rosmarus) (weight: 1197±148 kg, mean±SD, range 1013-1508 kg) at a terrestrial haul-out in Northeastern Greenland to determine their body water pool sizes and body water turnover rates....... During immobilization by use of etorphine HCl (reversed with diprenorphine HCl), a first blood sample was taken to measure background isotope levels. The animals were then enriched with deuterium oxide by infusion into the epidural vein. During recovery, while the animals were still on the beach, blood...

  1. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  2. Comparison of bile acid synthesis determined by isotope dilution versus fecal acidic sterol output in human subjects

    International Nuclear Information System (INIS)

    Duane, W.C.; Holloway, D.E.; Hutton, S.W.; Corcoran, P.J.; Haas, N.A.

    1982-01-01

    Fecal acidic sterol output has been found to be much lower than bile acid synthesis determined by isotope dilution. Because of this confusing discrepancy, we compared these 2 measurements done simultaneously on 13 occasions in 5 normal volunteers. In contrast to previous findings, bile acid synthesis by the Lindstedt isotope dilution method averaged 16.3% lower than synthesis simultaneously determined by fecal acidic sterol output (95% confidence limit for the difference - 22.2 to -10.4%). When one-sample determinations of bile acid pools were substituted for Lindstedt pools, bile acid synthesis by isotope dilution averaged 5.6% higher than synthesis by fecal acidic sterol output (95% confidence limits -4.9 to 16.1%). These data indicate that the 2 methods yield values in reasonably close agreement with one another. If anything, fecal acidic sterol outputs are slightly higher than synthesis by isotope dilution

  3. Isotope-dilution mass spectrometry in the measurement of plutonium isotope half-lives

    International Nuclear Information System (INIS)

    Abernathey, R.M.; Marsh, S.F.

    1981-01-01

    Isotope-dilution mass spectrometry has been used at Los Alamos to measure the half-lives of 239 Pu, 240 Pu, and 241 Pu. The latter was determined by measuring the rate of decrease of the 241 Pu/ 242 Pu ratio in an appropriate isotopic mixture over a period of several years. The half-lives of the two lighter isotopes are too long to be determined in this manner. They were determined by measuring the rate of production of the uranium daughter relative to a known added 233 U spike. Experimental procedures were designed to control sources of error and to permit a detailed statistical treatment which included all known sources of error and accounted for all covariances. The uncertainties, at the 95% confidence level, associated with the measured half-lives were less than 0.4% for 241 Pu and less than 0.2% for 239 Pu and 240 Pu

  4. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  5. Measurement parameter selection for quantitative isotope dilution gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Colby, B.N.; Rosecrance, A.E.; Colby, M.E.

    1981-01-01

    By use of the two-isotope model of isotope dilution, selection criteria were developed for identifying optimum m/z's for quantitation of compounds by gas chromatography/mass spectrometry. In addition, it was possible to predict the optimum ratio of naturally abundant to labeled compound and to identify appropriate data reduction methods. The validity of these predictions was confirmed by using experimental GC/MS data for several organic compounds

  6. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  7. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  8. Reverse isotope dilution method for determining benzene and metabolites in tissues

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.

    1988-01-01

    A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of the radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue

  9. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    Science.gov (United States)

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  10. Isotope-dilution analyses of the metallic elements

    International Nuclear Information System (INIS)

    Chastagner, P.

    1982-01-01

    The isotope-dilution mass spectroscopy (IDMS) technique has proven to be to be a reliable, versatile analytical tool. Its applications seem to be limited only by the ingenuity of the investigator. Among its advantages are: small sample size; general applicability; precision and accuracy; dynamic range; simplified chemistry; determination is fixed at the time and place of isotopic homogenization. The last listed item is especially important for nuclear safeguards and processes where inventories are critical. IDMS is now a routine analytical technique in geochemical and nuclear laboratories, and in many environmental laboratories. Microgram and nanogram samples are normally used, frequently with automatic mass spectrometers, in many of these routine applications. More advanced techniques permit picogram and sub picogram samples to be analyzed, and spike to sample ratios can range from 1:1 to 1:10 12 with detection limits at attogram levels for some elements. 3 figures, 3 tables

  11. Development of isotope dilution gamma-ray spectrometry for plutonium analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, T.K.; Parker, J.L. (Los Alamos National Lab., NM (United States)); Kuno, Y.; Sato, S.; Kurosawa, A.; Akiyama, T. (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan))

    1991-01-01

    We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing {approximately}98% of {sup 239}Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

  12. Reduction of measurement uncertainty by experimental design in high-order (double, triple, and quadruple) isotope dilution mass spectrometry: application to GC-MS measurement of bromide.

    Science.gov (United States)

    Pagliano, Enea; Mester, Zoltán; Meija, Juris

    2013-03-01

    Since its introduction a century ago, isotope dilution analysis has played a central role in developments of analytical chemistry. This method has witnessed many elaborations and developments over the years. To date, we have single, double, and even triple isotope dilution methods. In this manuscript, we summarize the conceptual aspects of isotope dilution methods and introduce the quadruple dilution and the concept of exact matching triple and quadruple dilutions. The comparison of isotope dilution methods is performed by determination of bromide ions in groundwater using novel ethyl-derivatization chemistry in conjunction with GC/MS. We show that the benefits of higher-order isotope dilution methods are countered with a greater need for careful experimental design of the isotopic blends. Just as for ID(2)MS, ID(3)MS and ID(4)MS perform best when the isotope ratio of one sample/spike blend is matched with that of a standard/spike blend (exact matching).

  13. A double isotope dilution method for assaying of polycyclic aromatic hydrocarbons in cigarette smoke condensate

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Chen, B.T.

    1988-01-01

    This report describes a double isotope dilution method for analysis of the polycyclic aromatic hydrocarbons (PAH) phenanthrene, fluor-anthene, pyrene, and benzo[a]pyrene in cigarette smoke particulates. The first isotope dilution used deuterated analogues of the first three PAH as internal standards. The second isotope dilution, for benzo[a]pyrene, used the tritiated analogue as an internal standard. The PAH were isolated from extracts of cigarette smoke particulates using a two-step procedure based on selective extraction from aqueous dimethyl sulfoxide (DMSO) followed by chromatography on silica gel extraction columns. After isolation, aliquots of the samples were analyzed for phenanthrene, pyrene, and fluoranthene by gas chromatography with mass spectrometric detection (GC/MS). Separate aliquots of the samples were analyzed for benzo[a]pyrene by high pressure liquid chromatography with fluorescence detection followed by liquid scintillation spectrometry. PAH levels from cigarette smoke condensates collected from different exposure modes were compared; no exposure-related differences were found. (author)

  14. Comprehensive analysis for major, minor and trace element contents and Sr-Nd-Pb-Hf isotope ratios in sediment reference materials, JSd-1 and MAG-1

    Digital Repository Service at National Institute of Oceanography (India)

    Nath, B.N.; Makishima, A.; Noordmann, J.; Tanaka, R.; Nakamura, E.

    (TFE) bomb at 245 degrees C for 96 hrs with Mg addition. The elemental concentration was measured by quadrupole type inductively coupled plasma source mass spectrometry (ICP-QMS) and sector field type ICP-MS (ICP-SFMS) using isotope dilution...

  15. Determination of photooxygenation products of rotenone with isotope dilution method

    International Nuclear Information System (INIS)

    Chubachi, Mitsuo; Hamada, Masayuki

    1975-01-01

    When rotenone dissolved in certain solvent was photochemically oxidized, rotenolones, dehydrorotenone and rotenonone were obtained as main products. In order to determine the quantitative yields of these compounds in photooxygenation products, four compounds mentioned above were labeled with carbon-14 and the isotope dilution method by these labeled compounds was applied to the product analysis. (auth.)

  16. Error analysis of isotope dilution mass spectrometry method with internal standard

    International Nuclear Information System (INIS)

    Rizhinskii, M.W.; Vitinskii, M.Y.

    1989-02-01

    The computation algorithms of the normalized isotopic ratios and element concentration by isotope dilution mass spectrometry with internal standard are presented. A procedure based on the Monte-Carlo calculation is proposed for predicting the magnitude of the errors to be expected. The estimation of systematic and random errors is carried out in the case of the certification of uranium and plutonium reference materials as well as for the use of those reference materials in the analysis of irradiated nuclear fuels. 4 refs, 11 figs, 2 tabs

  17. Redox substoichiometry in isotope dilution analysis Pt. 4

    International Nuclear Information System (INIS)

    Kambara, T.; Yoshioka, H.; Ugai, Y.

    1980-01-01

    The oxidation reaction of antimony(III) with potassium dichromate has been investigated radiometrically. The quantitative oxidation of antimony(III) was found to be not disturbed even in large amounts of tin(IV). On the basis of these results the redox substoichiometric isotope dilution analysis using potassium dichromate as the oxidizing agent was proposed for the determination of antimony in metallic tin. An antimony content of 1.22+-0.05 μg in metallic tin (10 mg) was determined without separation of the matrix element. (author)

  18. Validity of the tritiated thymidine method for estimating bacterial growth rates: measurement of isotope dilution during DNA synthesis

    International Nuclear Information System (INIS)

    Pollard, P.C.; Moriarty, D.J.W.

    1984-01-01

    The rate of tritiated thymidine incorporation into DNA was used to estimate bacterial growth rates in aquatic environments. To be accurate, the calculation of growth rates has to include a factor for the dilution of isotope before incorporation. The validity of an isotope dilution analysis to determine this factor was verified in experiments reported here with cultures of a marine bacterium growing in a chemostat. Growth rates calculated from data on chemostat dilution rates and cell density agreed well with rates calculated by tritiated thymidine incorporation into DNA and isotope dilution analysis. With sufficiently high concentrations of exogenous thymidine, de novo synthesis of deoxythymidine monophosphate was inhibited, thereby preventing the endogenous dilution of isoope. The thymidine technique was also shown to be useful for measuring growth rates of mixed suspensions of bacteria growing anaerobically. Thymidine was incorporated into the DNA of a range of marine pseudomonads that were investigated. Three species did not take up thymidine. The common marine cyanobacterium Synechococcus species did not incorporate thymidine into DNA

  19. Application of the mass spectrometry-isotope dilution technique for the determination of uranium contents in rocks

    International Nuclear Information System (INIS)

    Kakazu, M.H.; Iyer, S.S.

    1980-01-01

    Application of the spectrometric isotope dilution technique for the accurate determination of parts per million range of uranium in rock samples is described. The various aspects of the method like sample dissolution, ion exchange separation, mass spectrometric procedures are discussed. A single filament ionization source was employed for the isotope analysis. A carbon reduction method was used to reduce uranium oxide ions to uranium metal ions. The tracer solution for isotope dilution was prepared from National Bureau of Standards uranium isotopic Standard NBS U-970. Uranium contents are meassured for nine rock samples and the values obtained are compared with the uranium values measured by others workers. Errors caused in the uranium determination due to sample splitting problems as well as the incomplete acid digestion of the samples are discussed. (Author) [pt

  20. Determination of urea kinetics by isotope dilution with [C-13]urea and gas chromatography isotope ratio mass spectrometry (GC-IRMS) analysis

    NARCIS (Netherlands)

    Kloppenburg, Wybe; Wolthers, BG; Stellaard, F; Elzinga, H; Tepper, T; deJong, PE; Huisman, RM

    1. Stable urea isotopes can be used to study urea kinetics in humans, The use of stable urea isotopes far studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material, We devised a urea dilution for measurement of the distribution volume,

  1. Evaluation of isotopic dilution method for measuring N2 fixation in azolla: comparison with other methods

    International Nuclear Information System (INIS)

    Sah, R.N.; Goyal, S.S.; Rains, D.W.; Paige, D.F.

    1989-01-01

    An isotopic dilution method that overcomes the drawbacks of commonly used methods for measuring N 2 fixation by aquatic N‐fixers such as Azolla pinnata‐Anabaena azollae association (Azolla) is presented. The method was compared with 15 N2 gas (while maintaining CO 2 ) and the difference methods of measuring N 2 fixation. The isotopic dilution method was used for two conditions: a. For 15 N‐free growth medium, Azolla was pre‐enriched with 15 N, and N 2 fixation was determined by measuring the dilution of 15 N in the tissue. b. For the growth medium containing N, N2 fixation was determined by providing 15 N enriched ammonium sulfate in the growth medium and measuring 15 N to 14 N ratio in the tissue. An airtight chamber, necessary for 15 N 2 gas and acetylene reduction methods, was not representative of the growing environment of Azolla. Temperature in the airtight chamber was far from uniform and CO 2 was rapidly depleted. The isotopic dilution method is simpler, relatively inexpensive, subject to fewer errors and applicable to more diverse conditions, and yet was as accurate as 15 N2‐gas method. (author)

  2. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Li Xue; Fang Xiaowei; Yu Zhiqiang; Sheng Guoying; Wu Minghong; Fu Jiamo; Chen Huanwen

    2012-01-01

    Highlights: ► High throughput analysis of urinary creatinine is achieved by using ID-EESI–MS/MS. ► Urine sample is directly analyzed and no sample pre-treatment is required. ► Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI–MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 μg L −1 . Over the concentration range investigated (0.05–10 mg L −1 ), the calibration curve was obtained with satisfactory linearity (R 2 = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1–11.8% (n = 6) and 4.1–11.3% (n = 6), respectively. The isotope dilution EESI–MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85–111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI–MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  3. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  4. Assessment of vitamin A status in rats by isotope dilution: A simplified model

    International Nuclear Information System (INIS)

    Furr, H.C.; Cooper, D.A.; Olson, J.A.

    1990-01-01

    Isotope-dilution analysis of vitamin A status requires giving a known quantity of labeled vitamin A to the subject and measuring the ratio of labeled to unlabeled retinol in the blood after a period for equilibration. To calculate total body stores from the isotopic ratio of plasma retinol, several assumptions must be made. In considering new ways of better calculating liver vitamin A stores from isotope-dilution data, the authors used the data of Green et al. to estimate loss of vitamin A tracer as a function of time and of vitamin A status. This correction markedly improves the correlation between calculated and analyzed liver vitamin A stores and also quantitively explains the hyperbolic relationship between fraction of tracer dose recovered in liver and mass of liver vitamin A stores. Agreement of this model with experimental data suggests that efficiency of absorption and storage of vitamin A is not affected by vitamin A status. This model can be used to estimate both the amount of tracer needed for a given lower limit of detection and an optimum sampling time

  5. Isotope dilution mass spectrometry for nuclear material accountability measurements: dreams and reality

    International Nuclear Information System (INIS)

    Deron, S.; )

    1996-01-01

    Gravimetry, titration, coulometry and isotope dilution mass spectrometry are alternative techniques which can be used to obtain elemental assays of the desirable accuracy. The communication briefly describes the characteristics of the procedure and summarizes a wealth of experience accumulated during actual accountability verification activities

  6. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Xue [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Fang Xiaowei [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Yu Zhiqiang; Sheng Guoying [Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Wu Minghong [Shanghai Applied Radiation Institute, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Fu Jiamo [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Chen Huanwen, E-mail: chw8868@gmail.com [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China)

    2012-10-20

    Highlights: Black-Right-Pointing-Pointer High throughput analysis of urinary creatinine is achieved by using ID-EESI-MS/MS. Black-Right-Pointing-Pointer Urine sample is directly analyzed and no sample pre-treatment is required. Black-Right-Pointing-Pointer Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI-MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 {mu}g L{sup -1}. Over the concentration range investigated (0.05-10 mg L{sup -1}), the calibration curve was obtained with satisfactory linearity (R{sup 2} = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1-11.8% (n = 6) and 4.1-11.3% (n = 6), respectively. The isotope dilution EESI-MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85-111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI-MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  7. Redox substoichiometry in isotope dilution analysis Pt. 2

    International Nuclear Information System (INIS)

    Kambara, T.; Suzuki, J.; Yoshioka, H.; Nakajima, N.

    1978-01-01

    Isotope dilution analysis using the redox substoichiometric principle has been applied to the determination of antimony content in metallic zinc. As the substoichiometric reaction, the oxidation of trivalent to pentavalent antimony with potassium permanganate was used, followed by separation of these species by the BHPA extraction of trivalent antimony. Determination of antimony contents less than 0.5 μg was found to be possible with good accuracy, without separation of zinc ions. The antimony content in a metallic zinc sample was determined to be 19.7+-0.8 ppm, in good agreement with the results obtained by the other analytical methods. (author)

  8. Spectrophotometric-isotope dilution determination of arsenic in soils and rock

    Science.gov (United States)

    Brown, F.W.; Simon, F.O.; Greenland, L.P.

    1975-01-01

    Arsenic in soil and rock samples may be determined in part-per-million concentrations using a radiochemical-isotope dilution method. Arsenic in the sample plus added As76 tracer is separated as arsine and determined spectrophotometrically as a molybdenum blue complex. The As76 activity in the absorbing solution allows corrections for chemical losses. A lower limit of 1 ppm is determinate in a 0.5-g sample.

  9. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  10. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  11. Isotope dilution analysis for urinary fentanyl and its main metabolite, norfentanyl, in patients by isotopic fractionation using capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan). Faculty of Pharmacy and Pharmaceutical Sciences; Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-07-01

    Isotope dilution analysis was applied to determine urinary excretion of fentanyl (FT) and its main metabolite, norfentanyl (Nor-FT), by isotopic fractionation using a capillary gas chromatograph equipped with a surface ionization detector (SID). Urinary FT was determined quantitatively in the range of 0.4-40 ng/ml using deuterium labeled FT (FT-{sup 2}H{sub 19}), as an internal standard. We also performed isotope dilution analysis of Nor-FT in urine. N-Alkylation was necessary to sensitively detect Nor-FT with SID. Methyl derivative was selected from 3 kinds of N-alkyl derivatives to increase sensitivity and peak resolution, and to prevent interference with urinary compound. Nor-FT concentration was quantitatively determined in the range of 10-400 ng/ml using deuterium labeled Nor-FT (Nor-FT-{sup 2}H{sub 10}). No endogenous compounds or concomitant drugs interfered with the detection of FT and Nor-FT in the urine of patients. The present method will be useful for pharmacokinetic studies and the evaluation of drug interactions in FT metabolism. (author)

  12. Isotope dilution analysis for urinary fentanyl and its main metabolite, norfentanyl, in patients by isotopic fractionation using capillary gas chromatography

    International Nuclear Information System (INIS)

    Sera, Shoji; Goromaru, Tsuyoshi; Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-01-01

    Isotope dilution analysis was applied to determine urinary excretion of fentanyl (FT) and its main metabolite, norfentanyl (Nor-FT), by isotopic fractionation using a capillary gas chromatograph equipped with a surface ionization detector (SID). Urinary FT was determined quantitatively in the range of 0.4-40 ng/ml using deuterium labeled FT (FT- 2 H 19 ), as an internal standard. We also performed isotope dilution analysis of Nor-FT in urine. N-Alkylation was necessary to sensitively detect Nor-FT with SID. Methyl derivative was selected from 3 kinds of N-alkyl derivatives to increase sensitivity and peak resolution, and to prevent interference with urinary compound. Nor-FT concentration was quantitatively determined in the range of 10-400 ng/ml using deuterium labeled Nor-FT (Nor-FT- 2 H 10 ). No endogenous compounds or concomitant drugs interfered with the detection of FT and Nor-FT in the urine of patients. The present method will be useful for pharmacokinetic studies and the evaluation of drug interactions in FT metabolism. (author)

  13. Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS

    International Nuclear Information System (INIS)

    Fortunato, G.; Wunderli, S.

    2003-01-01

    The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained. This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO 3 /H 2 O 2 microwave digestion. The thallium isotope amount ratio (n( 205 Tl)/n( 203 Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n( 206 Pb)/n( 208 Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study ''lead in wine'' organised by the CCQM (Comite Consultatif pour la Quantite de Matiere, BIPM, Paris; the highest measurement authority for analytical chemical measurements). The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=k x uc, k=2) The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R 206,B of the blend between the enriched spike and the sample. (orig.)

  14. Determination of microquantities of silver in platinum by isotope dilution

    International Nuclear Information System (INIS)

    Yedinakova, V.; Sladkovska, Y.

    1980-01-01

    A method is described for determining microquantities of silver in platinum. It is based on isotope dilution by means of substoichiometric extraction of dithizonates with carbon tetrachloride. The determination of silver according to this technique is not interfered by zinc or gold in quantities exceeding the silver content by one order of magnitude nor by a great excess of platinum. In the presence of copper the addition of complexon is necessary. (author)

  15. Determination of the interchangeable heavy-metal fraction in soils by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Gaebler, H.E.; Bahr, A.; Mieke, B.

    1999-01-01

    An isotope dilution technique using enriched stable isotopes is applied to determine the interchangeable heavy-metal fraction in soils. Metals in two soil samples are extracted at constant pH, with water, NH 4 NO 3 , and EDTA. A spike of enriched stable isotopes is added to the suspension of sample and eluant at the beginning of the extraction. The heavy-metal fraction which exchanges with the added spike during the extraction is called the interchangeable fraction. The extractable heavy-metal fractions are obtained from the heavy-metal concentrations in the eluates. Isotope ratios and concentrations are determined by HR-ICP-MS. The isotope dilution technique described enables both the extractable and the interchangeable heavy-metal fractions to be determined in the same experiment. The combination of both results gives additional information on elemental availability under different conditions that cannot be obtained by analyzing the extractable heavy-metal fractions alone. It is demonstrated that in some cases different eluants just shift the distribution of the interchangeable fraction of an element between the solid and liquid phases (e.g., Pb and Cd in a topsoil sample) while the amount of the interchangeable fraction itself remains constant. For other elements, as Ni, Zn, and Cr, the use of different eluants (different pH, complexing agents) sometimes enlarges the interchangeable fraction. (orig.)

  16. Optimal sample to tracer ratio for isotope dilution mass spectrometry: the polyisotopic case

    International Nuclear Information System (INIS)

    Laszlo, G.; Ridder, P. de; Goldman, A.; Cappis, J.; Bievre, P. de

    1991-01-01

    The Isotope Dilution Mass Spectrometry (IDMS) measurement technique provides a means for determining the unknown amount of various isotopes of an element in a sample solution of known mass. The sample solution is mixed with an auxiliary solution, or tracer, containing a known amount of the same element having the same isotopes but of different relative abundances or isotopic composition and the induced change in the isotopic composition measured by isotope mass spectrometry. The technique involves the measurement of the abundance ratio of each isotope to a (same) reference isotope in the sample solution, in the tracer solution and in the blend of the sample and tracer solution. These isotope ratio measurements, the known element amount in the tracer and the known mass of sample solution are used to calculate the unknown amount of one isotope in the sample solution. Subsequently the unknown amount of element is determined. The purpose of this paper is to examine the optimization of the ratio of the estimated unknown amount of element in the sample solution to the known amount of element in the tracer solution in order to minimize the relative uncertainty in the determination of the unknown amount of element

  17. Vitamin A metabolism, kinetic behavior and utilization: Rationale for the continued development and use of an isotope dilution technique for assessing vitamin A stores in human populations

    International Nuclear Information System (INIS)

    Green, M.H.

    1997-01-01

    The paper discusses the applicability of isotope dilution method in general and oral isotope dilution in particular to the assessment of vitamin A status in humans. It also highlights some aspects of vitamin A intake and metabolism as related to isotope dilution method. Areas of methodological research and development in vitamin A research are also proposed

  18. Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS

    Science.gov (United States)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2005-04-01

    Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.

  19. Approach for domestic preparation of standard material (LSD spike) for isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Ishikawa, Fumitaka; Sumi, Mika; Chiba, Masahiko; Suzuki, Toru; Abe, Tomoyuki; Kuno, Yusuke

    2008-01-01

    The accountancy analysis of the nuclear fuel material at Plutonium Fuel Development Center of JAEA is performed by isotope dilution mass spectrometry (IDMS; Isotope Dilution Mass Spectrometry). IDMS requires the standard material called LSD spike (Large Size Dried spike) which is indispensable for the accountancy in the facilities where the nuclear fuel materials are handled. Although the LSD spike and Pu source material have been supplied from foreign countries, the transportation for such materials has been getting more difficult recently. This difficulty may affect the operation of nuclear facilities in the future. Therefore, research and development of the domestic LSD spike and base material has been performed at JAEA. Certification for such standard nuclear materials including spikes produced in Japan is being studied. This report presents the current status and the future plan for the technological development. (author)

  20. Comparison of total body water determinations in lactating women by anthropometry, water displacement, and deuterium isotope dilution

    International Nuclear Information System (INIS)

    Wong, W.; Butte, N.; Lee, L.; Garza, C.; Klein, P.

    1986-01-01

    To expand the limited data on the total body water in lactating women, the authors have determined total body water contents, in eight subjects from anthropometric measurements, water displacement, and isotope dilution of deuterium oxide. On the day of the study, their skinfold thicknesses were measured over the biceps and triceps muscles and at the suprailiac and subscapular areas. Their body densities were measured by water displacement. Deuterium oxide was administered orally at 100 mg/kg of body weight. One predose milk sample was collected from each subject. The milk samples were defatted by centrifugation and the milk water was reduced to hydrogen gas for hydrogen isotope ratio measurements by gas-isotope-ratio mass spectrometry. The results indicated that total body water in lactating women estimated from anthropometric measurements was 49.7 +/- 3.3% of body weight, by water displacement was 54.9 +/- 7.2%, and by isotope dilution was 50.8 +/- 3.7%

  1. Automated spike preparation system for Isotope Dilution Mass Spectrometry (IDMS)

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1990-01-01

    Isotope Dilution Mass Spectrometry (IDMS) is a method frequently employed to measure dissolved, irradiated nuclear materials. A known quantity of a unique isotope of the element to be measured (referred to as the ''spike'') is added to the solution containing the analyte. The resulting solution is chemically purified then analyzed by mass spectrometry. By measuring the magnitude of the response for each isotope and the response for the ''unique spike'' then relating this to the known quantity of the ''spike'', the quantity of the nuclear material can be determined. An automated spike preparation system was developed at the Savannah River Site (SRS) to dispense spikes for use in IDMS analytical methods. Prior to this development, technicians weighed each individual spike manually to achieve the accuracy required. This procedure was time-consuming and subjected the master stock solution to evaporation. The new system employs a high precision SMI Model 300 Unipump dispenser interfaced with an electronic balance and a portable Epson HX-20 notebook computer to automate spike preparation

  2. Nutritional assessment by isotope dilution analysis of body composition

    International Nuclear Information System (INIS)

    Szeluga, D.J.; Stuart, R.K.; Utermohlen, V.; Santos, G.W.

    1984-01-01

    The three components of body mass, body cell mass (BCM), extracellular fluid (ECF), and fat + extracellular solids (ECS: bone, tendon, etc) can be quantified using established isotope dilution techniques. With these techniques, total body water (TBW) and ECF are measured using 3H 2 O and 82 Bromine, respectively, as tracers. BCM is calculated from intracellular fluid (ICF) where ICF . TBW - ECF. Fat + ECS is estimated as: body weight - (BCM + ECF). TBW and ECF can be determined by either of two calculation methods, one requiring several timed plasma samples (extrapolation method) and one requiring a single plasma sample and a 4-h urine collection (urine-corrected method). The comparability of the two calculation methods was evaluated in 20 studies in 12 bone marrow transplant recipients. We found that for determination of TBW and ECF there was a very strong linear relationship (r2 greater than 0.98) between the calculation methods. Further comparisons (by t test, 2-sided) indicated that for the determination of ECF, the methods were not significantly (p greater than 0.90) different; however, TBW determined by the urine-corrected method was slightly (0.1 to 6%), but significantly (p less than 0.01) greater than that determined by the extrapolation method. Therefore, relative to the extrapolation method, the urine-corrected method ''over-estimates'' BCM and ''under-estimates'' fat + ECS since determination of these compartment sizes depends on measurement of TBW. We currently use serial isotope dilution studies to monitor the body composition changes of patients receiving therapeutic nutritional support

  3. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  4. Candidate processes for diluting the 235U isotope in weapons-capable highly enriched uranium

    International Nuclear Information System (INIS)

    Snider, J.D.

    1996-02-01

    The United States Department of Energy (DOE) is evaluating options for rendering its surplus inventories of highly enriched uranium (HEU) incapable of being used to produce nuclear weapons. Weapons-capable HEU was earlier produced by enriching uranium in the fissile 235 U isotope from its natural occurring 0.71 percent isotopic concentration to at least 20 percent isotopic concentration. Now, by diluting its concentration of the fissile 235 U isotope in a uranium blending process, the weapons capability of HEU can be eliminated in a manner that is reversible only through isotope enrichment, and therefore, highly resistant to proliferation. To the extent that can be economically and technically justified, the down-blended uranium product will be made suitable for use as commercial reactor fuel. Such down-blended uranium product can also be disposed of as waste if chemical or isotopic impurities preclude its use as reactor fuel

  5. Isotopic and chemical dilution effects on the vibrational relaxation rate of some totally symmetric motions of liquid acetonitrile

    International Nuclear Information System (INIS)

    Marri, E.; Morresi, A.; Paliani, G.; Cataliotti, R.S.; Giorgini, M.G.

    1999-01-01

    The vibrational dephasing of the ν 1 (C-H, C-D stretching) and ν 3 (C-H, C-D bending) symmetric motions of liquid acetonitrile in its light and fully deuterated forms has been studied in the frame of the vibrational time correlation functions obtained as Fourier transforms of the isotropic Raman spectral distributions and interpreted within the Kubo theory. In addition, the experimental isotropic profiles have been analysed within the bandshape approach formulated by analytical Fourier transformation of the Kubo vibrational time correlation functions in order to derive the relaxation parameters in the frequency domain. The effects of the isotopic (CH 3 CN/CD 3 CN and vice versa) and chemical (CCl 4 ) dilution on the bandshapes and on the vibrational relaxation parameters have been studied. It was observed that the decay rate of ν 1 mode is insensitive to the isotopic dilution but varies appreciably with chemical (CCl 4 ) dilution. The vibrational dephasing of ν 3 mode is qualitatively, but not quantitatively, affected in the same way by chemical dilution and shows a slower modulation regime than that exhibited by the stretching mode. Unlikely from the latter, the ν 3 mode results are slightly affected by the isotopic dilution. Phase relaxation mechanisms of these two motions of acetonitrile in the liquid state are proposed on the basis of these data, and a comparison is made with the results earlier published. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  6. Determination of traces of iridium with thiodibenzoylmethane by substoichiometric isotope dilution analysis

    International Nuclear Information System (INIS)

    Roebisch, G.; Bansse, W.; Ludwig, E.

    1980-01-01

    Iridium(III or IV) reacts with thiodibenzoylmethane on heating at pH 6 to form a 1:3 complex, which can be concentrated by extraction into chloroform. Based on this reaction, a reproducible, selective determination of iridium is achieved by means of substoichiometric isotope dilution analysis, based on 192 Ir. The linear range is 1-11 nmol of iridium. (Auth.)

  7. Redox substoichiometric isotope dilution analysis of metallic arsenic for antimony

    International Nuclear Information System (INIS)

    Kambara, Tomihisa; Yoshioka, Hiroe; Suzuki, Junsuke; Shibata, Yasue.

    1979-01-01

    In 1 M HCl solution Sb(III) reacts with N-benzoyl-N-phenylhydroxylamine (BPHA) to form a complex extractable into chloroform while the extraction of Sb(V) is negligible. The redox substoichiometric isotope dilution analysis based on this reaction was applied to the determination of antimony in metallic arsenic. After the dissolution of metallic arsenic, Sb(V) was separated from As(V) by a tribenzylamine extraction from 8 M HCl solution and the extracted Sb(V) was stripped into 0.5 M NaOH solution. Thereafter, all the Sb(V) were completely reduced to Sb(III) by bubbling SO 2 gas through 3 M HCl solution. As the substoichiometric reaction, the oxidation of Sb(III) to Sb(V) by a substoichiometric amount of potassium dichromate was used, followed by separation of these species by the BPHA extraction of Sb(III). The substoichiometric oxidation of Sb(III) was found to be quantitative over HCl concentration range from 0.8 to 1.2 M. The amount of antimony was determined by isotope dilution analysis using the method of carrier amount variation. By the present method the determination of as small as 0.36 μg antimony was accomplished with a good accuracy (relative error; 5.6%) and also the method was successfully applied to the determination of antimony in arsenic samples containing known amounts of Sb(III) and in metallic arsenic. The present method gives reliable results with the good accuracy and precision. (author)

  8. Quantitation of Poly(ADP-Ribose) by Isotope Dilution Mass Spectrometry

    DEFF Research Database (Denmark)

    Zubel, Tabea; Martello, Rita; Bürkle, Alexander

    2017-01-01

    PARP inhibitors, which represent a novel class of promising chemotherapeutics. Previously, we have developed a bioanalytical platform based on isotope dilution mass spectrometry (LC-MS/MS) to quantify cellular PAR with unequivocal chemical specificity in absolute terms with femtomol sensitivity...... research, as well as in drug development (Martello et al. ACS Chem Biol 8(7):1567-1575, 2013; Mangerich et al. Toxicol Lett 244:56-71, 2016). Here, we present an improved and adjusted version of the original protocol by Martello/Mangerich et al., which uses UPLC-MS/MS instrumentation....

  9. Quantitative analysis of 39 polybrominated diphenyl ethers by isotope dilution GC/low-resolution MS.

    Science.gov (United States)

    Ackerman, Luke K; Wilson, Glenn R; Simonich, Staci L

    2005-04-01

    A GC/low-resolution MS method for the quantitative isotope dilution analysis of 39 mono- to heptabrominated diphenyl ethers was developed. The effects of two different ionization sources, electron impact (EI) and electron capture negative ionization (ECNI), and the effects of their parameters on production of high-mass fragment ions [M - xH - yBr](-) specific to PBDEs were investigated. Electron energy, emission current, source temperature, ECNI system pressure, and choice of ECNI reagent gases were optimized. Previously unidentified enhancement of PBDE high-mass fragment ion [M - xH - yBr](-) abundance was achieved. Electron energy had the largest impact on PBDE high-mass fragment ion abundance for both the ECNI and EI sources. By monitoring high-mass fragment ions of PBDEs under optimized ECNI source conditions, quantitative isotope dilution analysis of 39 PBDEs was conducted using nine (13)C(12) labeled PBDEs on a low-resolution MS with low picogram to femtogram instrument detection limits.

  10. Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS).

    Science.gov (United States)

    Agarande, M; Benzoubir, S; Bouisset, P; Calmet, D

    2001-08-01

    Trace levels (pg kg(-1)) of 241Am in sediments were determined by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS) using a microconcentric nebulizer. 241Am was isolated from major elements like Ca and Fe by different selective precipitations. In further steps. Am was first separated from other transuranic elements and purified by anion exchange and extraction chromatography prior to the mass spectrometric measurements. The ID HR ICP-MS results are compared with isotope dilution alpha spectrometry.

  11. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material

    International Nuclear Information System (INIS)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-01-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound esposure time. Due to the complex matrix of this fly ash material, a two-steps purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs

  12. Comparison of isotope dilution and excretion methods for determining the half-life of ascorbic acid in the guinea pig

    International Nuclear Information System (INIS)

    Kipp, D.E.; Rivers, J.M.

    1984-01-01

    The half-life of ascorbic acid (AA) in guinea pigs was investigated by the isotope dilution and excretion methods. The dilution method measures [1-14C]AA disappearance from the plasma, whereas the excretion method measures the elimination of [1-14C]AA and the metabolites from the body. Two groups of animals underwent both isotope studies in reverse order. Animals were conditioned to the experimental procedures and fed 2.5 mg AA/100 g body weight orally to maintain a daily intake of the vitamin independent of food consumption. The two isotope procedures imposed similar stress on the animals, as determined by plasma cortisol levels and body weight changes. The AA half-life calculations of the rapidly exchangeable pool by the isotope dilution method yielded values of 1.23 and 0.34 hours for the two groups, respectively. The half-life of the slowly exchangeable pool for the two groups was 60.2 and 65.8 hours, respectively. The half-life of AA in the rapidly exchangeable pool, as measured by the excretion studies, was 4.57-8.75 hours. For the slowly exchangeable pool, it was 146-149 hours. The longer half-life of both pools obtained with the excretion method indicates that the isotope is disappearing from the plasma more rapidly than it is being excreted. This suggests that a portion of the [1-14C]AA leaving the plasma is removed to a body pool that is not sampled by the isotope excretion method

  13. Improved analytical procedure for the determination of 210Pb and 210Po using alpha-spectrometric isotope dilution

    International Nuclear Information System (INIS)

    Urnezis, P.W.; Holtzman, R.B.

    1981-01-01

    An isotope dilution method has been incorporated into the 210 Pb- 210 Po analysis. A known amount of 209 Po is added to the sample before analysis. Then both 209 Po and 210 Po are deposited on a silver planchet which is assayed in an alpha spectrometer to determine the activities of each isotope. The recoveries generally range from 70% to 90%

  14. Precise determination of dissolved silica in seawater by ion-exclusion chromatography isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Nonose, Naoko; Cheong, Chikako; Ishizawa, Yukari; Miura, Tsutomu; Hioki, Akiharu

    2014-08-20

    Ion exclusion chromatograph (IEC) isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) (IEC-ID-ICP-MS) was developed for measurement of dissolved silica in seawater, which was applied to production of certified reference materials (CRMs) of three concentration levels of nutrients (high, medium and low levels). IEC-ICP-MS has been employed to separate dissolved silica from seawater matrix. In the present study, in order to solve substantial problems due to spectral interference in ICP-MS and to improve the accuracy of IEC-ICP-MS beyond standard addition or conventional calibration methods, ID method was coupled with ICP-sector field mass spectrometry (operated under medium resolution,i.e., m/Δm=4000). In addition, effects of various operating parameters in ICP-MS on a silicon background level were also investigated to obtain lower background equivalent concentration (BEC). As a result, 3 ng g(-1) of the BEC and 0.5 % of relative standard uncertainties were achieved in the analyses of dissolved silica in seawater samples at concentration levels from 4.0 mg kg (-1) to 0.8 mg kg(-1) as silicon. The developed method was successfully validated by analyses of an artificial seawater containing a known amount of silicate and the seawater certified reference material MOOS-2 produced by the National Research Council Canada. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  16. Validation of methods to measure uranium isotopes using magnetic sector mass spectrometry with inductively coupled plasma source

    International Nuclear Information System (INIS)

    Hernandez M, H.; Rios L, M. J.; Romero G, E. T.

    2017-10-01

    The mass spectrometry technique with inductively coupled plasma source (Icp-Ms) has been widely used to measure isotopic ratios of elements toxic to human health. Reason for which, in this work several measurement methods for the analysis of uranium isotopes in different matrices were implemented using magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). Groundwater, sediment, soil and urine were the matrices analyzed, which were supplied by intercomparison tests conducted by the IAEA and Association for the Promotion of Quality Control of Medical Biology Analysis in Radio-toxicology. The procedures used in the treatment of soil, sediment and water samples were based on US EPA methods. In the case of the urine sample, the preparation was rapid (1:20 dilution). The average of the results obtained in yield of each matrix was 94, 71, 72 and 78% for water, urine, soil and sediment respectively. In addition, the precision in terms of standard relative deviation was less than 5% and the accuracy was less than 4%. In conclusion, the Icp-SFMS is a very sensitive technique for measuring isotopes of U in different matrices. However, careful tuning is necessary, especially in the mass regions of interest 234, 235 and 238 if an external quantification is considered using natural U solutions. (Author)

  17. Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ohata, Masaki; Miura, Tsutomu

    2014-01-01

    Highlights: • Accurate analytical method of Br in plastic was studied by isotope dilution ICPMS. • A microwave acid digestion using quartz vessel was suitable for Br analysis. • Sample dilution by NH 3 solution could remove memory effect for ICPMS measurement. • The analytical result of the ID-ICPMS showed consistency with that of INAA. • The ID-ICPMS developed could apply to certification of Br in candidate plastic CRM. - Abstract: The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH 3 ) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH 3 solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive

  18. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  19. Automatic processing of isotopic dilution curves obtained by precordial detection

    International Nuclear Information System (INIS)

    Verite, J.C.

    1973-01-01

    Dilution curves pose two distinct problems: that of their acquisition and that of their processing. A study devoted to the latter aspect only was presented. It was necessary to satisfy two important conditions: the treatment procedure, although applied to a single category of curves (isotopic dilution curves obtained by precordial detection), had to be as general as possible; to allow dissemination of the method the equipment used had to be relatively modest and inexpensive. A simple method, considering the curve processing as a process identification, was developed and should enable the mean heart cavity volume and certain pulmonary circulation parameters to be determined. Considerable difficulties were encountered, limiting the value of the results obtained though not condemning the method itself. The curve processing question raised the problem of their acquisition, i.e. the number of these curves and their meaning. A list of the difficulties encountered is followed by a set of possible solutions, a solution being understood to mean a curve processing combination where the overlapping between the two aspects of the problem is accounted for [fr

  20. Quantification of Labile Soil Mercury by Stable Isotope Dilution Techniques

    Science.gov (United States)

    Shetaya, Waleed; Huang, Jen-How; Osterwalder, Stefan; Alewell, Christine

    2016-04-01

    Mercury (Hg) is a toxic element that can cause severe health problems to humans. Mercury is emitted to the atmosphere from both natural and anthropogenic sources and can be transported over long distances before it is deposited to aquatic and terrestrial environments. Aside from accumulation in soil solid phases, Hg deposited in soils may migrate to surface- and ground-water or enter the food chain, depending on its lability. There are many operationally-defined extraction methods proposed to quantify soil labile metals. However, these methods are by definition prone to inaccuracies such as non-selectivity, underestimation or overestimation of the labile metal pool. The isotopic dilution technique (ID) is currently the most promising method for discrimination between labile and non-labile metal fractions in soil with a minimum disturbance to soil-solid phases. ID assesses the reactive metal pool in soil by defining the fraction of metal both in solid and solution phases that is isotopically-exchangeable known as the 'E-value'. The 'E-value' represents the metal fraction in a dynamic equilibrium with the solution phase and is potentially accessible to plants. This is carried out by addition of an enriched metal isotope to soil suspensions and quantifying the fraction of metal that is able to freely exchange with the added isotope by measuring the equilibrium isotopic ratio by ICP-MS. E-value (mg kg-1) is then calculated as follows: E-Value = (Msoil/ W) (CspikeVspike/ Mspike) (Iso1IAspike -Iso2IAspikeRss / Iso2IAsoil Rss - Iso1IAsoil) where M is the average atomic mass of the metal in the soil or the spike, W is the mass of soil (kg), Cspike is the concentration of the metal in the spike (mg L-1), Vspike is the volume of spike (L), IA is isotopic abundance, and Rss is the equilibrium ratio of isotopic abundances (Iso1:Iso2). Isotopic dilution has been successfully applied to determine E-values for several elements. However, to our knowledge, this method has not yet

  1. Isotope separation by magnetic fields

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1978-01-01

    One of the isotopes of an element having several isotopes can be separated from the others in a dense, neutral plasma. Thus initially a neutral plasma is prepared including the element in question. This may consist of positive ions and negative electrons or alternatively of positive and negative ions, or else of a mixture of positive ions, negative ions and electrons. The plasma may then be injected into a magnetic field or may be generated in the field where more energy is imparted to a selected isotope than to the others. Finally, the isotopes are separated from each other on the basis of their differential energies. For example, the selected isotope may be given more energy than the others by stimulating it within the plasma at its resonant frequency which may be close to the cyclotron frequency, either by an electric field or by a magnetic field. In order to excite the other isotope, a different resonant frequency is required which depends on the plasma density, the relative concentration of electrons if the plasma contains electrons, the strength of the magnetic field, the ratio of charge to mass of the isotope, and possibly on the physical parameters of the plasma apparatus itself, such as the ratio of the length of the plasma column to its radius. The more energetic isotope may be separated by energy dependent chemical reactions, it may be collected by a positively biased probe or else the isotopes may be separated from each other by magnetic fields or in various other ways

  2. Stable isotope dilution analysis by thermal ionization mass spectrometry. Pt. 2

    International Nuclear Information System (INIS)

    Broekman, A.; Raaphorst, J.G. van

    1984-01-01

    The combination of stable isotope dilution analysis (SIDA) and thermal ionization mass spectrometry (TIMS) is in use for lead and uranium determination at milligram per kilogram levels for over 20 years. However, several other elements can also be determined accurately by SIDA/TIMS. In this study the determinations of cadmium and copper are described. Details of the digestion, electrochemical and ion-exchange separations and the loading of the elements on a filament are given. The advantages of the SIDA/TIMS technique are shown and illustrated with results for several certified reference materials. (orig.) [de

  3. Oxygen isotope fine structure and fluid throughput of the Tongonan geothermal field, Philippines

    International Nuclear Information System (INIS)

    Scott, G.L.; Blattner, P.; Department of Scientific and Industrial Research, Lower Hutt

    1986-01-01

    Oxygen isotope ratios for 40 reservoir rocks from the plutonic basement and overlying andesitic rocks, and 14 separated geothermal quartz samples from the volcanics, range from 2.5 to 9.9 per mil. The lowest δ 18 O values (average 2.9 per mil) in diorite cores from wells 401, 407 and 410 are located in the most productive northwest (Mahiao) sector of the field. In the Malitbog sector, the average δ 18 O values for basement rocks are higher (c. 4.6 per mil). Plutonic rock samples from the Mamban (well MN1) sector, located outside the present-day field margin, are only slightly altered (6 per mil) except possibly near the contact zone between the basement and overlying volcanics. The highest cumulative fluid/rock ratios are calculated for the Mahiao sector, whereas Malitbog is possibly a relatively recent extension of the field. Relatively shallow (Bao Formation) quartz has δ 18 O values suggesting past tectonic uplift

  4. Determination of nanogram amounts of iodide by electrochemical isotope dilution analysis

    International Nuclear Information System (INIS)

    Gabrielsson, A.-B.; Beronius, P.

    1976-01-01

    A known quantity of iodide in ethanol as solvent was labelled with 131 I-and subsequently diluted with a predetermined amount of inactive iodide. Specific activities before and after the isotope dilution were established by anodically depositing small fractions of the halide in each sample on rotating silver micro electrodes and determining the activities of the electrodeposits. The lowest concentration of iodide used in any analysis was 1.10 -5 M. Further deposition studies revealed that iodide can be deposited with 1 100% current efficiency on the rotating silver micro electrode for concentration down to 2.4.10 -6 M. Electrodeposition studies for still lower concentrations have not yet been undertaken. These results suggest that amounts of iodide ion down to about 10 ng, and possibly still smaller quantitites, might be determined with the method developed. Amounts from 42 ng to 1 μg can be determined with an error of 2.5%. (T.G.)

  5. Quantitation of Rotundone in Grapefruit (Citrus paradisi) Peel and Juice by Stable Isotope Dilution Assay.

    Science.gov (United States)

    Nakanishi, Akira; Fukushima, Yusuke; Miyazawa, Norio; Yoshikawa, Keisuke; Maeda, Tomoko; Kurobayashi, Yoshiko

    2017-06-21

    Aroma extract dilution analyses of the aromas of peels and juices of white and pink grapefruits revealed that rotundone, responsible for peppery, spicy, and woody odors, was detected for the first time at high flavor dilution factors of 256-1024. In both juices, rotundone was detected at the highest flavor dilution factor of 1024. Rotundone in grapefruits was quantitated by a stable isotope dilution assay with a newly synthesized deuterium-labeled internal standard, rotundone-d 2,3 : its levels were 2180 and 1920 ng/kg in white and pink grapefruit peels and 29.6 and 49.8 ng/kg in white and pink grapefruit juices, respectively. On the basis of these results, sensory analysis was performed to assess the effects of rotundone on a white grapefruit juice aroma reconstitute. This sensory analysis revealed that rotundone does not impart a woody odor or affect any of the existing attributes, but increases various attributes, thus confirming that rotundone is indispensable for the aroma of grapefruit juice.

  6. Acetone and acetaldehyde determination in tomato juice by isotopic dilution

    International Nuclear Information System (INIS)

    Piva, M.-T.; Crouzet, J.

    1977-01-01

    Acetone and acetaldehyde content of tomato juice were determined by isotope dilution techniques. The juice is added to 14 C labelled compounds, carried along by nitrogen at low pressure. The mixture of 2.4 dinitrophenylhydrazones obtained from volatile compounds is separated by thin layer chromatography on silica gel and then on alumina. A determination of radioactivity and concentration of acetone and acetaldehyde 2,4 dinitrophenylhydrazones obtained after separation and elution allow to calculate the content of these two compounds in the initial product with the same sample. This technique could be used for determination of methanol and ethanol after transformation in 3,5 dinitrobenzoates [fr

  7. High field Moessbauer study of dilute Ir-(Fe) alloys

    International Nuclear Information System (INIS)

    Takabatake, Toshiro; Mazaki, Hiromasa; Shinjo, Teruya.

    1981-01-01

    The magnetic behavior of very dilute Fe impurities in Ir has been studied by means of Moessbauer measurement in external fields up to 80 kOe at 4.2 K. The saturation hyperfine field increases in proportion to the external field up to the maximum magnetic field available. This means that for a localized spin fluctuation system IrFe, the effective magnetic moment associated with Fe impurities is induced in proportion to the external field. No anomalous spectrum was observed with a very dilute sample (--10 ppm 57 Co), indicating that the interaction between impurities is responsible for the anomalous spectrum previously observed with a less homogeneous sample. (author)

  8. Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ohata, Masaki, E-mail: m-oohata@aist.go.jp; Miura, Tsutomu

    2014-07-21

    Highlights: • Accurate analytical method of Br in plastic was studied by isotope dilution ICPMS. • A microwave acid digestion using quartz vessel was suitable for Br analysis. • Sample dilution by NH{sub 3} solution could remove memory effect for ICPMS measurement. • The analytical result of the ID-ICPMS showed consistency with that of INAA. • The ID-ICPMS developed could apply to certification of Br in candidate plastic CRM. - Abstract: The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH{sub 3}) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH{sub 3} solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive.

  9. The IDA-80 measurement evaluation programme on mass spectrometric isotope dilution analysis of uranium and plutonium. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Golly, W.; Spannagel, G.; Kernforschungszentrum Karlsruhe G.m.b.H.; Bievre, P. de; Wolters, W.

    1984-12-01

    The main objective was the acquisition of basic data on the uncertainties involved in the mass spectrometric isotope dilution analysis as applied to the determination of uranium and plutonium in active feed solutions of reprocessing plants. The element concentrations and isotopic compositions of all test materials used were determined by CBNM and NBS with high accuracy. The more than 60000 analytical data reported by the participating laboratories were evaluated by statistical methods applied mainly to the calculation of estimates of the variances for the different uncertainty components contributing to the total uncertainty of this analytical technique. Attention was given to such topics as sample ageing, influence of fission products, spike calibration, ion fractionation, Pu-241 decay correction, minor isotope measurement and errors in data transfer. Furthermore, the performance of the 'dried sample' technique and the 'in-situ' spiking method of undiluted samples of reprocessing fuel solution with U-235/Pu-242 metal alloy spikes, were tested successfully. Considerable improvement of isotope dilution analysis in this safeguards relevant application during the last decade is shown as compared to the results obtained in the IDA-72 interlaboratory experiment, organized by KfK in 1972 on the same subject. (orig./HP) [de

  10. Quantification of fentanyl in serum by isotope dilution analysis using capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan); Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-06-01

    The quantitative determination of fentanyl (FT) in serum was examined by isotope dilution analysis using a capillary gas chromatograph equipped with a surface ionization detector. The separation of FT and its deuterated analogue, FT-{sup 2}H{sub 19}, was achieved within 15 min a column temperature of 260degC by using a 25 m column. Measurement of the samples prepared by the addition of a known amount of FT in the range of 0.2 to 40 ng/ml with 20 ng/ml of FT-{sup 2}H{sub 19} to human control serum allowed observation of a linear relationship between the peak area ratio and the added amount ratio. The correlation coefficient obtained by regression analysis was 0.999. The advantage of the present isotope dilution method was demonstrated by comparison with other FT analogues which substituted a propionyl group with an acetyl group or a phenethyl group with a benzyl group as the internal standard. The present method was used to determine the serum level of FT in surgical patients after i.v. administration. No endogenous compounds and concomitant drugs interfered with the detection of FT or FT-{sup 2}H{sub 19}. This method was considered to be useful for the pharmacokinetic study of FT in patients. (author)

  11. Quantification of fentanyl in serum by isotope dilution analysis using capillary gas chromatography

    International Nuclear Information System (INIS)

    Sera, Shoji; Goromaru, Tsuyoshi; Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-01-01

    The quantitative determination of fentanyl (FT) in serum was examined by isotope dilution analysis using a capillary gas chromatograph equipped with a surface ionization detector. The separation of FT and its deuterated analogue, FT- 2 H 19 , was achieved within 15 min a column temperature of 260degC by using a 25 m column. Measurement of the samples prepared by the addition of a known amount of FT in the range of 0.2 to 40 ng/ml with 20 ng/ml of FT- 2 H 19 to human control serum allowed observation of a linear relationship between the peak area ratio and the added amount ratio. The correlation coefficient obtained by regression analysis was 0.999. The advantage of the present isotope dilution method was demonstrated by comparison with other FT analogues which substituted a propionyl group with an acetyl group or a phenethyl group with a benzyl group as the internal standard. The present method was used to determine the serum level of FT in surgical patients after i.v. administration. No endogenous compounds and concomitant drugs interfered with the detection of FT or FT- 2 H 19 . This method was considered to be useful for the pharmacokinetic study of FT in patients. (author)

  12. Improvement of sample preparation for input plutonium accountability measurement by isotope dilution gammy-ray spectroscopy

    International Nuclear Information System (INIS)

    Nishida, K.; Kuno, Y.; Sato, S.; Masui, J.; Li, T.K.; Parker, J.L.; Hakkila, E.A.

    1992-01-01

    The sample preparation method for the isotope dilution gamma-ray spectrometry (IDGS) technique has been further improved for simultaneously determining the plutonium concentration and isotopic composition of highly irradiated spent-fuel dissolver solutions. The improvement includes using ion-exchange filter papers (instead of resin beads, as in two previous experiments) for better separation and recovery of plutonium from fission products. The results of IDGS measurements for five dissolver solutions are in good agreement with those by mass spectrometry with ∼0.4% for plutonium concentration and ∼0.1% for 239 Pu isotopic composition. The precision of the plutonium concentration is ∼1% with a 1-h count time. The technique could be implemented as an alternative method for input accountability and verification measurements in reprocessing plants

  13. Comparison between isotope dilution and activation analysis as a method for determining the macro content of mercury

    International Nuclear Information System (INIS)

    Soedyartomo; Sunoko, S.R.

    1975-01-01

    It is true that the mercury content in the environment should be measured accurately because of its toxicity even at levels of microgram order. The assessment of hazards due to environmental contamination with mercury is based on the results of the metal analysis in a number of different samples. Consequently, the study of the character of analytical methods used, i.e. their accuracy, precision, sensitivity, etc. is essential. A brief description on the microanalysis methods of mercury as given. The discussion of the results obtained from analysing some sludge and water by means of isotope dilution and destructive thermal neutron activation analysis is also presented. It is found that both methods are suitable for routine work. It can be concluded that the isotope dilution method has some advantages. It is more simple, more sensitive, more rapid, and has lower radiation hazard. (author)

  14. A novel quantification strategy of transferrin and albumin in human serum by species-unspecific isotope dilution laser ablation inductively coupled plasma mass spectrometry (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Liuxing, E-mail: fenglx@nim.ac.cn; Zhang, Dan; Wang, Jun; Shen, Dairui; Li, Hongmei

    2015-07-16

    Highlights: • Species-unspecific ID-PAGE-LA-ICP-MS was used to quantify Alb and Tf in human serum. • Addition methods of species-unspecific {sup 34}S spike were evaluated. • Isotope change conditions were investigated to reach satisfactory “isotope equilibration”. • Human serum CRM (ERM-DA470k/IFCC) was used to validate the new arrangements. • The developed method offers potential for accurate quantification of protein by ID-PAGE-LA-ICP-MS. - Abstract: Species-specific (SS) isotope dilution analysis with gel electrophoresis (GE)-laser ablation (LA)-ICP-MS is a promising technique for the quantification of particular metal-binding proteins in biological samples. However, unavailable isotopically enriched spike and metal losses in GE separation are main limitations for SS-isotope dilution PAGE-LA-ICP-MS. In this study, we report for the first time the absolute quantification of transferrin (Tf) and albumin (Alb) in human serum by non-denaturing (native) GE combined with species-unspecific isotope dilution mass spectrometry (IDMS). In order to achieve a homogeneous distribution of both protein and isotope-enriched spike (simulated isotope equilibration), immersing the protein strips with {sup 34}S spike solution after gel electrophoresis was demonstrated to be an effective way of spike addition. Furthermore, effects of immersion time and {sup 34}S spike concentration were investigated to obtain optimal conditions of the post-electrophoresis isotope dilution method. The relative mass of spike and ablated sample (m{sub sp}/m{sub sam}) in IDMS equation was calculated by standard Tf and Alb proteins, which could be applied to the quantification of Tf and Alb in ERM-DA470k/IFCC for method confirmation. The results were in agreement with the certified value with good precision and small uncertainty (1.5–3%). In this method, species-specific spike protein is not necessary and the integrity of the heteroatom-protein could be maintained in sample preparation

  15. A novel quantification strategy of transferrin and albumin in human serum by species-unspecific isotope dilution laser ablation inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Feng, Liuxing; Zhang, Dan; Wang, Jun; Shen, Dairui; Li, Hongmei

    2015-01-01

    Highlights: • Species-unspecific ID-PAGE-LA-ICP-MS was used to quantify Alb and Tf in human serum. • Addition methods of species-unspecific 34 S spike were evaluated. • Isotope change conditions were investigated to reach satisfactory “isotope equilibration”. • Human serum CRM (ERM-DA470k/IFCC) was used to validate the new arrangements. • The developed method offers potential for accurate quantification of protein by ID-PAGE-LA-ICP-MS. - Abstract: Species-specific (SS) isotope dilution analysis with gel electrophoresis (GE)-laser ablation (LA)-ICP-MS is a promising technique for the quantification of particular metal-binding proteins in biological samples. However, unavailable isotopically enriched spike and metal losses in GE separation are main limitations for SS-isotope dilution PAGE-LA-ICP-MS. In this study, we report for the first time the absolute quantification of transferrin (Tf) and albumin (Alb) in human serum by non-denaturing (native) GE combined with species-unspecific isotope dilution mass spectrometry (IDMS). In order to achieve a homogeneous distribution of both protein and isotope-enriched spike (simulated isotope equilibration), immersing the protein strips with 34 S spike solution after gel electrophoresis was demonstrated to be an effective way of spike addition. Furthermore, effects of immersion time and 34 S spike concentration were investigated to obtain optimal conditions of the post-electrophoresis isotope dilution method. The relative mass of spike and ablated sample (m sp /m sam ) in IDMS equation was calculated by standard Tf and Alb proteins, which could be applied to the quantification of Tf and Alb in ERM-DA470k/IFCC for method confirmation. The results were in agreement with the certified value with good precision and small uncertainty (1.5–3%). In this method, species-specific spike protein is not necessary and the integrity of the heteroatom-protein could be maintained in sample preparation process. Moreover, the

  16. Determination of total uranium by mass spectrometry utilizing the isotopic dilution technique

    International Nuclear Information System (INIS)

    Cretella, R.F.; Noutary, C.J.; Servant, R.E.

    1981-01-01

    The isotopic dilution associated to mass spectrometry is a high-sensitivity technique that allows to work with microquantities of the sample, making it possible to analize the content in highly radioactive solutions with excellent accuracy and minimum risk. The proposed technique is described and its results are discussed through the analysis of: 1) A synthetic sample that simulates dissolved spent fuel elements; 2) Uranium dioxide of nuclear purity and 3) Uranium concentrate. 233 U(ORNL) was employed as a tracer and a Nuclide 12-90-SU mass spectrometer of simple magnetic focus as measurement instrument. The accuracy reached in the analyses is better than 0.5% with a reliability of 95%. The analysis of the errors shows that their main contributing source are the errors in the measurement of the isotopic ratios. (M.E.L.) [es

  17. Certification of mercury in acrylonitrile butadiene styrene by using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Hu Hai; Ma Liandi; Wei Chao; Zhou Tao; Wang Jun; Zhao Motian; Li Jinying

    2008-01-01

    Under the framework of a co-certification system for the development of Certified Reference Materials (CRMs) among China, Japan and Korea, the 1st co-certification campaign of mercury in acrylonitrile butadiene styrene (ABS) for Japanese CRMs was taken. In this campaign isotope dilution mass spectrometry (IDMS) was used. First, all abundances of Hg in spike 202 Hg, CRM and ABS were analyzed by MC-ICP-MS before the certification. Then the concentrations of 202 Hg and Hg in ABS were determined with IDMS by Q-ICP-MS. A new procedure to reduce memory effect was used. first, dilute with 5 μg/g Au solution for 1 min; then, 5 μg/g EDTA solution for 2 min. The results accord to each other very well and this implies that the co-certification system can run swimmingly. (authors)

  18. Mass spectrometic isotope dilution analysis of Am and Cm in spent fuels

    International Nuclear Information System (INIS)

    Wantschik, M.; Koch, L.; Commission of the European Communities, Karlsruhe; Ganser, B.

    1983-01-01

    Spent nuclear fuels contain Am and Cm in the 10 ppb to 100 ppm range. Because of this low abundance and the necessity of handling small samples of the highly toxic fuel material only a mass-spectrometric isotope dilution analysis can give sufficiently accurate results. Since suitable spikes and/or standards have been lacking, this method has not been applied. Using known masses (+- 0.1%) of Am-241 and Cm-244 metal, Am-243 and Cm-248 spikes were calibrated to an accuracy of better than 0.2%. The standards were reanalysed by chemical titration and several radiometric techniques. The chemical conditioning is based on ionexchange chromatography with alpha-hydroxyisobutyric acid. A sample size of 10 -7 g is sufficient. For the mass-spectrometric measurement 10 -9 g of the elements are required. The accuracy for the determination of the main isotope is 0.5%. (orig./BRB)

  19. The separation and determination of fatty acids by isotopic dilution and radiogas-liquid chromatography

    International Nuclear Information System (INIS)

    Beardsley, D.A.

    1981-01-01

    A number of static phases have been evaluated for the GLC separation of fatty acids. Of those investigated, only AT 1200 was capable of resolving the isomeric forms of the acids. A radiogas-liquid chromatographic method incorporating isotopic dilution analysis has been developed for the determination of n-butyric acid. The proposed method has been applied to the determination of the acid in hydrolysed butter fat and milk chocolate extracts. (author)

  20. Quantification of root associated nitrogen fixation in kallar grass as estimated by sup/15/nitrogen isotope dilution

    International Nuclear Information System (INIS)

    Malik, K.A.; Zafar, Y.

    1985-01-01

    Present investigations were made by using sup/15/N isotope dilution technique to quantitatively estimate BNF in Kallar grass when grown under controlled conditions in nutrient solution and inoculated with N sub/2/-fixing bacteria. Azospirillum brasilense and two isolates from the rhizosphere of kallar grass were used as inoculant. After harvest acetylen reduction of roots, total yield, total N and sup/15/ N analysis were made. Total-N in inoculated treatments was 2-3 times higher than in control and so were the fresh and dry weight yields. The estimates based on isotopic dilution indicated that 50-70 percent N in the plant was derived from BNF in case of inoculated treatment. The results based on N balance gave relatively lower values of 40-60 percent of total N derived from fixation. The data revealed that in Kallar grass a substantial amount of plant N is derived from BNF. (orig./A.B.)

  1. The dilute random field Ising model by finite cluster approximation

    International Nuclear Information System (INIS)

    Benyoussef, A.; Saber, M.

    1987-09-01

    Using the finite cluster approximation, phase diagrams of bond and site diluted three-dimensional simple cubic Ising models with a random field have been determined. The resulting phase diagrams have the same general features for both bond and site dilution. (author). 7 refs, 4 figs

  2. Application of isotope dilution for the determination of thorium in biological samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Igarashi, Yasuhito; Shiraishi, Kunio; Takaku, Yuichi; Masuda, Kimihiko; Seki, Riki; Yamamoto, Masayoshi.

    1992-01-01

    The applicability of isotope dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS) was examined for Th in biological samples. A naturally occurring isotope of Th(Th-230) was used as the spiking isotope. The concentration of Th-230 in the final sample solution was about 50 - 60 pg/ml; an isotope ratio of 232/230 could be measured with a relative standard deviation of less than 2%. The error magnification depended on the amount of Th-232 being concomitant with the Th-230. Though it was shown that one ng of Th-232 could be determined with reasonable precision with a tracer of the present purity, more care should be taken to reduce any source of systematic error. (author)

  3. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels.

    Science.gov (United States)

    Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.

  4. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g-1 levels

    International Nuclear Information System (INIS)

    Boulyga, Sergei F.; Tibi, Markus; Heumann, Klaus G.

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3 x 10 -13 g g -1 for Pu isotopes in soil samples containing uranium at a concentration of a few μg g -1 . The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH + and PbO 2 + ions and by the peak tail of 238 U + ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of α-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of 239+240 Pu (9.8±3.0 mBq g -1 ) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4±0.2 mBq g -1 . However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if ''hot'' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples. (orig.)

  5. High-precision quadruple isotope dilution method for simultaneous determination of nitrite and nitrate in seawater by GCMS after derivatization with triethyloxonium tetrafluoroborate

    Energy Technology Data Exchange (ETDEWEB)

    Pagliano, Enea, E-mail: enea.pagliano@nrc-cnrc.gc.ca; Meija, Juris; Mester, Zoltán

    2014-05-01

    Highlights: • High-precision determination of nitrite and nitrate in seawater. • Use of quadruple isotope dilution. • Aqueous Et₃O⁺BF₄]⁻ derivatization chemistry for GCMS analysis of nitrite and nitrate. Abstract: Quadruple isotope dilution mass spectrometry (ID⁴MS) has been applied for simultaneous determination of nitrite and nitrate in seawater. ID⁴MS allows high-precision measurements and entails the use of isotopic internal standards (¹⁸O-nitrite and ¹⁵N-nitrate). We include a tutorial on ID⁴MS outlining optimal experimental design which generates results with low uncertainties and obviates the need for direct (separate) evaluation of the procedural blank. Nitrite and nitrate detection was achieved using a headspace GCMS procedure based on single-step aqueous derivatization with triethyloxonium tetrafluoroborate at room temperature. In this paper the sample preparation was revised and fundamental aspects of this chemistry are presented. The proposed method has detection limits in the low parts-per-billion for both analytes, is reliable, precise, and has been validated using a seawater certified reference material (MOOS-2). Simplicity of the experimental design, low detection limits, and the use of quadruple isotope dilution makes the present method superior to the state-of-the-art for determination of nitrite and nitrate, and an ideal candidate for reference measurements of these analytes in seawater.

  6. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  7. An application of nitrogen microwave-induced plasma mass spectrometry to isotope dilution analysis of selenium in marine organisms

    Energy Technology Data Exchange (ETDEWEB)

    Shirasaki, Toshihiro [Hitachi Instruments Engineering Co. Ltd., Hitachinaka, Ibaraki (Japan); Yoshinaga, Jun; Morita, Masatoshi; Okumoto, Toyoharu; Oishi, Konosuke

    1996-01-01

    Nitrogen microwave-induced plasma mass spectrometry was studied for its applicability to the isotope dilution analysis of selenium in biological samples. Spectroscopic interference by calcium, which is present in high concentrations in biological samples, was investigated. No detectable background spectrum was observed for the major selenium isotopes of {sup 78}Se and {sup 80}Se. No detectable interferences by sodium, potassium, calcium and phosphorus on the isotope ratio {sup 80}Se/{sup 78}Se were observed up to concentration of 200 mg/ml. The method was applied to the analysis of selenium in biological reference materials of marine organisms. The results showed good agreement between the certified and found values. (author).

  8. Validation of multi-element isotope dilution ICPMS for the analysis of basalts

    Energy Technology Data Exchange (ETDEWEB)

    Willbold, M.; Jochum, K.P.; Raczek, I.; Amini, M.A.; Stoll, B.; Hofmann, A.W. [Max-Planck-Institut fuer Chemie, Mainz (Germany)

    2003-09-01

    In this study we have validated a newly developed multi-element isotope dilution (ID) ICPMS method for the simultaneous analysis of up to 12 trace elements in geological samples. By evaluating the analytical uncertainty of individual components using certified reference materials we have quantified the overall analytical uncertainty of the multi-element ID ICPMS method at 1-2%. Individual components include sampling/weighing, purity of reagents, purity of spike solutions, calibration of spikes, determination of isotopic ratios, instrumental sources of error, correction of mass discrimination effect, values of constants, and operator bias. We have used the ID-determined trace elements for internal standardization to improve indirectly the analysis of 14 other (mainly mono-isotopic trace elements) by external calibration. The overall analytical uncertainty for those data is about 2-3%. In addition, we have analyzed USGS and MPI-DING geological reference materials (BHVO-1, BHVO-2, KL2-G, ML3B-G) to quantify the overall bias of the measurement procedure. Trace element analysis of geological reference materials yielded results that agree mostly within about 2-3% relative to the reference values. Since these results match the conclusions obtained by the investigation of the overall analytical uncertainty, we take this as a measure for the validity of multi-element ID ICPMS. (orig.)

  9. The analysis of uranium in environmental sample by mass spectrometer combined with isotopic dilution

    International Nuclear Information System (INIS)

    Fu Zhonghua; Jia Baoting; Han Jun

    2003-01-01

    Uranium in the environmental sample was analyzed by mass spectrometer combined with isotopic dilution. Before mass spectrometer analysis, samples were dissolved in a concentrated acidic solution containing HNO 3 , HF and HClO 4 and chemically processed to suit the analysis requirement. Analysis results indicated that the uranium content was 0.08 μg/g in river water, 0.1 μg/g in evergreen foliage, and 5-11 μg/g in surface soil respectively. (authors)

  10. Isotope dilution alpha spectrometry for the determination of plutonium concentration in irradiated fuel dissolver solution : IDAS and R-IDAS

    International Nuclear Information System (INIS)

    Ramaniah, M.V.; Jain, H.C.; Aggarwal, S.K.; Chitambar, S.A.; Kavimandan, V.D.; Almaula, A.I.; Shah, P.M.; Parab, A.R.; Sant, V.L.

    1980-01-01

    The report presents a new technique, Isotope Dilution Alpha Spectrometry (IDAS) and Reverse Isotope Dilution Alpha Spectrometry (R-IDAS) for determining the concentration of plutonium in the irradiated fuel dissolver solution. The method exploits sup(238)Pu in IDAS and sup(239)Pu in R-IDAS as a spike and provides an alternative method to Isotope Dilution Mass Spectrometry (IDMS) which requires enriched sup(242)Pu as a spike. Depending upon the burn-up of the fuel, sup(238)Pu or sup(239)Pu is used as a spike to change the sup(238)Pu/(sup(239)Pu+sup(240)Pu)α activity ratio in the sample by a factor of 10. This change is determined by α-spectrometry on electrodeposited sources using a solid state silicon surface barrier detector coupled to a multichannel analyser. The validity of a simple method based on the geometric progression (G.P.) decrease for the far tail of the spectrum to correct for the tail contribution of sup(238)Pu peak (5.50 MeV) to the low energy sup(239)Pu + sup(240)Pu peak (5.17 MeV) is established. Results for the plutonium concentration on different irradiated fuel dissolver solutions with burn-uo ranging from J,000 to 100,000 MWD/TU are presented and compared with those obtained by IDMS. The values obtained by IDAS or R-IDAS and IDMS agree within 0.5%. (auth.)

  11. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Within the framework of the Safeguards Project of the Federal Republic of Germany at the Nuclear Research Center Karlsruhe an analytical intercomparison program was carried out in cooperation with 22 laboratories of 13 countries or international organizations. The main objective was the acquisition of basic data on the errors involved in the mass spectrometric isotope dilution analysis if it is applied to the determination of uranium and plutonium in diluted active feed solutions of reprocessing plants in routine operation. The results were evaluated by statistical methods mainly in regard to the calculation of the estimates of the variances for the different error components contributing to the total error of this analytical technique. Furthermore, the performance of two new methods for sample conditioning suggested by the International Atomic Energy Agency, Vienna, and the European Institute for Transuranium Elements (EURATOM), Karlsruhe, was successfully tested. The results of some investigations on the stability of diluted high active feed solutions and on comparison analysis by X-ray fluorescence spectrometry are also included. Data on the analytical efforts (manhours) invested in this study are reported as well as general experiences made in the organization and performance of an experiment on such an extended international level. (orig.) [de

  12. Evaluation for dinitrogen fixation of induced wheat nodules by 15N isotope dilution method

    International Nuclear Information System (INIS)

    Yao Yunyin; Zhen Ming; Chang Xizhong

    1993-11-01

    The results in pot experiments showed that the treating of 2,4-D and Azorhizobium caulinodans (2,4-D+A) could induce para-nodule formation on wheat roots. Plants treated grew normally. The plant height and dry weight are significantly higher than reference plants which are treated with 2,4-D+azorhizobium sterilized (2,4-D+AS). The nitrogenase activity is detected by ARA method. The N yield of most treated plants, especially in root systems, is higher than reference group that is measured by Kjeldahl method. The atom % 15 N excess in leaf and stem of treated plants measured by 15 N isotope dilution method is lower than that of reference group. Through four years experiments, it shows that para-nodules of wheat treated with 2,4-D+A could fix N 2 from air, but the ability of nitrogen fixation is lower and unstable. Although the nodulation efficiency could reach 100%, not each para-nodule induced can present activity of dinitrogen fixation. The amount of N fixed is 0.05∼18.1 mg/pot (0.01∼3.87 mg/plant). The net %Ndfa is 2.32%∼18.07%. The free-living N 2 fixing activity of azorhizobium is detected by 15 N isotope dilution method. The calculation of %Ndfa of nodulated wheat accurately is also discussed

  13. Vitamin A equivalency and apparent absorption of ß-carotene in ileostomy subjects using a dual-isotope dilution technique

    NARCIS (Netherlands)

    Bouwman, C.A.; Naber, T.H.J.; Breemen, van R.B.; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.M.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of ß-carotene in two diets using a dual-isotope dilution technique and the apparent ß-carotene absorption as measured by the oral–faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  14. Vitamin A equivalency and apparent absorption of beta-carotene in ileostomy subjects using a dual-isotope dilution technique.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; Naber, T.H.; Breemen, R.B. van; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of beta-carotene in two diets using a dual-isotope dilution technique and the apparent beta-carotene absorption as measured by the oral-faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  15. Dinitrogen fixation in white clover grown in pure stand and mixture with ryegrass estimated by the immobilized 15N isotope dilution method

    DEFF Research Database (Denmark)

    Jørgensen, F.V.; Jensen, E.S.; Schjørring, J.K.

    1999-01-01

    Dinitrogen fixation in white clover (Trifolium repens L.) grown in pure stand and mixture with perennial ryegrass (Lolium perenne L.) was determined in the field using N-15 isotope dilution and harvest of the shoots. The apparent transfer of clover N to perennial ryegrass was simultaneously...... assessed. The soil was labelled either by immobilizing N-15 in organic matter prior to establishment of the sward or by using the conventional labelling procedure in which N-15 fertilizer is added after sward establishment. Immobilization of N-15 in the soil organic matter has not previously been used...

  16. Determination of Cd and Pb in human blood by isotope dilution inductively coupled plasma mass spectrometry : International comparison

    International Nuclear Information System (INIS)

    Park, Chang Joon; Suh, Jeong Ki; Lee, Sang Hwa

    1996-01-01

    Inorganic analytical laboratory of Korea Research Institute of Standards and Science participated in an interlaboratory comparison program operated by Quebec Toxicology Centre of Canada in 1994 and again in 1995. The objective of this program is to enable participating laboratories to assess reproducibility and accuracy of their analytical results for trace toxic elements in human biological fluids. This laboratory determined Cd and Pb concentrations in 3 levels of human blood samples by isotope dilution inductively coupled plasma mass spectrometry. 0.5 mL of blood sample is added to the digestion bomb together with 2 mL of nitric acid and enriched spike isotopes and then decomposed in the microwave digestion system. The decomposed sample is diluted to 10 mL and nebulized into ICP-MS. The Cd and Pb values reported by all participating laboratories are presented and compared. The values reported by this laboratory are within the acceptable range of target values. (author)

  17. Characterizing uranium oxide reference particles for isotopic abundances and uranium mass by single particle isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Kraiem, M.; Richter, S.; Erdmann, N.; Kühn, H.; Hedberg, M.; Aregbe, Y.

    2012-01-01

    Highlights: ► A method to quantify the U mass in single micron particles by ID-TIMS was developed. ► Well-characterized monodisperse U-oxide particles produced by an aerosol generator were used. ► A linear correlation between the mass of U and the volume of particle(s) was found. ► The method developed is suitable for determining the amount of U in a particulate reference material. - Abstract: Uranium and plutonium particulate test materials are becoming increasingly important as the reliability of measurement results has to be demonstrated to regulatory bodies responsible for maintaining effective nuclear safeguards. In order to address this issue, the Institute for Reference Materials and Measurements (IRMM) in collaboration with the Institute for Transuranium Elements (ITU) has initiated a study to investigate the feasibility of preparing and characterizing a uranium particle reference material for nuclear safeguards, which is finally certified for isotopic abundances and for the uranium mass per particle. Such control particles are specifically required to evaluate responses of instruments based on mass spectrometric detection (e.g. SIMS, TIMS, LA-ICPMS) and to help ensuring the reliability and comparability of measurement results worldwide. In this paper, a methodology is described which allows quantifying the uranium mass in single micron particles by isotope dilution thermal ionization mass spectrometry (ID-TIMS). This methodology is characterized by substantial improvements recently achieved at IRMM in terms of sensitivity and measurement accuracy in the field of uranium particle analysis by TIMS. The use of monodisperse uranium oxide particles prepared using an aerosol generation technique developed at ITU, which is capable of producing particles of well-characterized size and isotopic composition was exploited. The evidence of a straightforward correlation between the particle volume and the mass of uranium was demonstrated in this study

  18. Effective field treatment of the annealed bond-dilute transverse Ising model

    International Nuclear Information System (INIS)

    Silva, P.R.; Sa Barreto, F.C. de

    1983-01-01

    The dilution of the spin-1/2 transverse Ising Model is studied by means of an effective field type treatment based on an extension of Callen's relation to the present model. The thermodynamics of the diluted model is obtained and the results are shown to be an improvement over the standard mean field treatment. The results are also compared with the Monte Carlo calculation for the spin-infinite transverse Ising Model. (Author) [pt

  19. Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Sergio Cueto; Ruiz Encinar, Jorge, E-mail: ruizjorge@uniovi.es; García Alonso, J. Ignacio, E-mail: jiga@uniovi.es

    2014-09-24

    Highlights: • Purity assessment of peptide standards applicable to any water soluble peptide. • Online {sup 13}C isotope dilution mass spectrometry. • Mass flow chromatogram from measured 44/45 isotope ratios. • Validation by the analysis of NIST 8327. - Abstract: We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online {sup 13}C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of {sup 13}C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99 °C provides quantitative oxidation to {sup 12}CO{sub 2} and {sup 13}CO{sub 2} respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO{sub 2}, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards.

  20. Hydrogen isotope exchange of organic compounds in dilute acid at elevated temperatures

    International Nuclear Information System (INIS)

    Werstiuk, N.H.

    1987-01-01

    Introduction of one or more deuterium (or tritium) atoms into organic molecules can be accomplished in many ways depending on the nature of the substrate and the extent and sterochemistry of deuteriation or tritiation required. Some of the common methods include acid- and base-catalyzed exchange of carbonyl compounds, metal hydride reductions, dissolving metal reductions, catalytic reduction of double bonds, chromatographic exchange, homogeneous and heterogeneous metal-catalyzed exchange, base-catalyzed exchange of carbon acids other than carbonyl compounds and acid-catalyzed exchange via electrophilic substitution. Only the latter three methods have been used for perdeuteriation of organic compounds. A very useful compendium of labeling methods with examples has been available to chemists for some time. Although metal-catalyzed exchange has been used extensively, the method suffers from some deficiencies: irreproducibility of catalyst surfaces, catalyst poisoning, side reactions such as coupling and hydrogenolysis of labile groups and low deuterium incorporation. Usually a number of cycles are required with fresh catalyst and fresh deuterium source to achieve substantial isotope incorporation. Acid-catalyzed exchange of aromatics and alkenes, strongly acidic media such as liquid DBr, concentrated DBr, acetic acid/stannic chloride, concentrated D 3 PO 4 , concentrated DC1, D 3 PO 4 /BF 3 SO 2 , 50-80% D 2 SO 4 and DFSO 4 /SbF 5 at moderate temperatures (<100 degrees) have been used to effect exchange. The methods are not particularly suitable for large scale deuteriations because of the cost and the fact that the recovery and upgrading of the diluted deuterium pool is difficult. This paper describes the hydrogen isotope exchange of a variety of organic compounds in dilute aqueous acid (0.1-0.5 M) at elevated temperatures (150-300 degrees)

  1. Rapid and Precise Measurement of Serum Branched-Chain and Aromatic Amino Acids by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Yang, Ruiyue; Dong, Jun; Guo, Hanbang; Li, Hongxia; Wang, Shu; Zhao, Haijian; Zhou, Weiyan; Yu, Songlin; Wang, Mo; Chen, Wenxiang

    2013-01-01

    BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs) have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standar...

  2. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Pak, Yong Nam

    2016-01-01

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA

  3. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Pak, Yong Nam [Dept. of Chemistry Education, Korea National University of Education, Cheongju (Korea, Republic of)

    2016-11-15

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA.

  4. The diluted tri-dimensional spin-one Ising model with crystal field interactions

    International Nuclear Information System (INIS)

    Saber, M.

    1988-09-01

    3D spin-one Ising models with nearest-neighbour ferromagnetic interactions with crystal-field exhibit tricritical behaviour. A new method that applies to a wide class of random systems is used to study the influence of site and bond dilution on this behaviour. We have calculated temperature-crystal-field-concentration phase diagrams and determined, in particular, the influence of dilution on the zero temperature tricritical temperature. (author). 10 refs, 8 figs

  5. Thermodynamics of a dilute XX chain in a field

    Energy Technology Data Exchange (ETDEWEB)

    Timonin, P. N., E-mail: pntim@live.ru [Southern Federal University, Physics Research Institute (Russian Federation)

    2016-06-15

    Gapless phases in ground states of low-dimensional quantum spin systems are rather ubiquitous. Their peculiarity is a remarkable sensitivity to external perturbations due to permanent criticality of such phases manifested by a slow (power-low) decay of pair correlations and the divergence of the corresponding susceptibility. A strong influence of various defects on the properties of the system in such a phase can then be expected. Here, we consider the influence of vacancies on the thermodynamics of the simplest quantum model with a gapless phase, the isotropic spin-1/2 XX chain. The existence of the exact solution of this model gives a unique opportunity to describe in detail the dramatic effect of dilution on the gapless phase—the appearance of an infinite series of quantum phase transitions resulting from level crossing under the variation of a longitudinal magnetic field. We calculate the jumps in the field dependences of the ground-state longitudinal magnetization, susceptibility, entropy, and specific heat appearing at these transitions and show that they result in a highly nonlinear temperature dependence of these parameters at low T. Also, the effect of enhancement of the magnetization and longitudinal correlations in the dilute chain is established. The changes of the pair spin correlators under dilution are also analyzed. The universality of the mechanism of the quantum transition generation suggests that similar effects of dilution can also be expected in gapless phases of other low-dimensional quantum spin systems.

  6. Crystal Fields in Dilute Rare-Earth Metals Obtained from Magnetization Measurements on Dilute Rare-Earth Alloys

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.

    1974-01-01

    Crystal field parameters of Tb, Dy, and Er in Sc, Y, and Lu are summarized. These parameters are obtained from magnetization measurements on dilute single crystals, and successfully checked by a number of different methods. The crystal field parameters vary unpredictably with the rare-earth solute....... B40, B60, and B66 are similar in Y and Lu. Crystal field parameters for the pure metals Tb, Dy, and Er are estimated from the crystal fields in Y and Lu....

  7. Dilution and Mixing in transient velocity fields: a first-order analysis

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe, P. J.; Fiori, Aldo; Bellin, Alberto

    2017-04-01

    An appealing remediation technique is in situ oxidation, which effectiveness is hampered by difficulties in obtaining good mixing of the injected oxidant with the contaminant, particularly when the contaminant plume is contained and therefore its deformation is physically constrained. Under such conditions (i.e. containment), mixing may be augmented by inducing temporal fluctuations of the velocity field. The temporal variability of the flow field may increase the deformation of the plume such that diffusive mass flux becomes more effective. A transient periodic velocity field can be obtained by an engineered sequence of injections and extractions from wells, which may serve also as a hydraulic barrier to confine the plume. Assessing the effectiveness of periodic flows to maximize solute mixing is a difficult task given the need to use a 3D setup and the large number of possible flow configurations that should be analyzed in order to identify the optimal one. This is the typical situation in which analytical solutions, though approximated, may assist modelers in screening possible alternative flow configurations such that solute dilution is maximized. To quantify dilution (i.e. a precondition that enables reactive mixing) we utilize the concept of the dilution index [1]. In this presentation, the periodic flow takes place in an aquifer with spatially variable hydraulic conductivity field which is modeled as a Stationary Spatial Random Function. We developed a novel first-order analytical solution of the dilution index under the hypothesis that the flow can be approximated as a sequence of steady state configurations with the mean velocity changing with time in intensity and direction. This is equivalent to assume that the characteristic time of the transient behavior is small compared to the period characterizing the change in time of the mean velocity. A few closed paths have been analyzed quantifying their effectiveness in enhancing dilution and thereby mixing

  8. Uncertainty assessment in gamma spectrometric measurements of plutonium isotope ratios and age

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H., E-mail: henrik.ramebeck@foi.se [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden); Nygren, U.; Tovedal, A. [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Ekberg, C.; Skarnemark, G. [Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden)

    2012-09-15

    A method for the assessment of the combined uncertainty in gamma spectrometric measurements of plutonium composition and age was evaluated. Two materials were measured. Isotope dilution inductively coupled plasma sector field mass spectrometry (ID-ICP-SFMS) was used as a reference method for comparing the results obtained with the gamma spectrometric method for one of the materials. For this material (weapons grade plutonium) the measurement results were in agreement between the two methods for all measurands. Moreover, the combined uncertainty in all isotope ratios considered in this material (R{sub Pu238/Pu239}, R{sub Pu240/Pu239}, R{sub Pu241/Pu239}, and R{sub Am241/Pu241} for age determination) were limited by counting statistics. However, the combined uncertainty for the other material (fuel grade plutonium) were limited by the response fit, which shows that the uncertainty in the response function is important to include in the combined measurement uncertainty of gamma spectrometric measurements of plutonium.

  9. Uranium determination in sea water using the isotopic dilution technique and HR-ICPMS

    International Nuclear Information System (INIS)

    Pereira, Marcio Henrique da Costa; Sarkis, Jorge Eduardo de Souza; Hortellani, Marcos Antonio; Nascimento, Marcos R.L.

    2009-01-01

    In this work, the uranium total and the isotopic composition in seawater were calculated using the isotopic dilution applied to the mass spectrometry. The used tracer was a 233 U solution . Near 99 % of the present salts in the matrix were separated by evaporation up to the saturation point. The uranium present in aqueous phase was separated from the matrix through the ion exchange chromatography using the strong Dowex 1 x 8 200-400 mesh anionic resin in chloridric medium 12 M. The analyses were performed in a high resolution mass spectrometer with plasma inductively coupled source. The method validation was done using the seawater standard CASS-4 (Near shore Seawater Reference Material for Trace metals) produced by the NRC C. The procedure allowed to obtain the fractions exempt of salts, having as consequence a greater stability in the analytical signal, and a rise in the instrumental revenue for a great number of samples. The uranium found in the samples was present in levels considered naturals and were obtained with a precision near 2 %

  10. Determination of mercury in coal by isotope dilution cold-vapor generation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Long, S.E.; Kelly, W.R.

    2002-04-01

    A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a Hg-201 isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin chloride. Measurements of Hg-201/Hg-202 isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is similar to 40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is similar to 0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.

  11. Application and validation of isotope dilution method (IDM) for predicting bioavailability of hydrophobic organic contaminants in soil.

    Science.gov (United States)

    Wang, Jie; Taylor, Allison; Schlenk, Daniel; Gan, Jay

    2018-05-01

    Risk assessment of hydrophobic organic contaminants (HOCs) using the total chemical concentration following exhaustive extraction may overestimate the actual availability of HOCs to non-target organisms. Existing methods for estimating HOC bioavailability in soil have various operational limitations. In this study, we explored the application of isotope dilution method (IDM) to quantify the accessible fraction (E) of DDTs and PCBs in both historically-contaminated and freshly-spiked soils. After addition of 13 C or deuterated analogues to a soil sample, the phase distribution of isotope-labeled and native chemicals reached an apparent equilibrium within 48 h of mixing. The derived E values in the three soils ranged from 0.19 to 0.82, depending on the soil properties and also the contact time of HOCs (i.e., aging). The isotope dilution method consistently predicted greater accumulation into earthworm (Eisenia fetida) than that by polyethylene (PE) or solid phase microextraction (SPME) sampler, likely because desorption in the gut enhanced bioavailability of soil-borne HOCs. A highly significant linear regression (R 2  = 0.91) was found between IDM and 24-h Tenax desorption, with a slope statistically identical to 1. The IDM-derived accessible concentration (C e ) was further shown to accurately predict tissue residues in earthworm exposed in the same soils. Given the relatively short duration and simple steps, IDM has the potential to be readily adopted for measuring HOC bioaccessibility in soil and for improving risk assessment and evaluation of remediation efficiency. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Ying; Shi, Zeming; Zong, Qinxia; Wu, Peng; Su, Jing [Sichuan Provincial Key Laboratory of Nuclear Technology in Geology, College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu 610059 (China); Liu, Rui, E-mail: liur.ray@gmail.com [Mineral Resources Chemistry Key Laboratory of Sichuan Higher Education Institutions, College of Materials and Chemistry and Chemical Engineering, Chengdu University of Technology, Chengdu 610059 (China)

    2014-02-17

    Graphical abstract: -- Highlights: •Simple, sensitive, and accurate method is established for mercury determination in cosmetics. •The sample preparation procedure is highly simplified. •Isotope dilution efficiently eliminates matrix effect. •First report of using formic acid based method in combination with PVG-ID-ICP MS for mercury quantitation in cosmetics. -- Abstract: A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched {sup 201}Hg isotopic spike is added to cosmetics and the isotope ratios of {sup 201}Hg/{sup 202}Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL{sup −1}. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.

  13. Development of isotope dilution-liquid chromatography/mass spectrometry combined with standard addition techniques for the accurate determination of tocopherols in infant formula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joonhee; Jang, Eun-Sil; Kim, Byungjoo, E-mail: byungjoo@kriss.re.kr

    2013-07-17

    Graphical abstract: -- Highlights: •ID-LC/MS method showed biased results for tocopherols analysis in infant formula. •H/D exchange of deuterated tocopherols in sample preparation was the source of bias. •Standard addition (SA)-ID-LC/MS was developed as an alternative to ID-LC/MS. •Details of calculation and uncertainty evaluation of the SA-IDMS were described. •SA-ID-LC/MS showed a higher-order metrological quality as a reference method. -- Abstract: During the development of isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) for tocopherol analysis in infant formula, biased measurement results were observed when deuterium-labeled tocopherols were used as internal standards. It turned out that the biases came from intermolecular H/D exchange and intramolecular H/D scrambling of internal standards in sample preparation processes. Degrees of H/D exchange and scrambling showed considerable dependence on sample matrix. Standard addition-isotope dilution mass spectrometry (SA-IDMS) based on LC/MS was developed in this study to overcome the shortcomings of using deuterium-labeled internal standards while the inherent advantage of isotope dilution techniques is utilized for the accurate recovery correction in sample preparation processes. Details of experimental scheme, calculation equation, and uncertainty evaluation scheme are described in this article. The proposed SA-IDMS method was applied to several infant formula samples to test its validity. The method was proven to have a higher-order metrological quality with providing very accurate and precise measurement results.

  14. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    Science.gov (United States)

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-03

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  15. Estimation of endogenous faecal calcium in buffalo (BOS bubalis) by isotope dilution technique

    International Nuclear Information System (INIS)

    Singh, S.; Sareen, V.K.; Marwaha, S.R.; Sekhon, B.; Bhatia, I.S.

    1973-01-01

    Detailed investigations on the isotope-dilution technique for the estimation of endogenous faecal calcium were conducted with buffalo calves fed on growing ration. The ration consisted of wheat straw, green lucerne and concentrate mix. The endogenous faecal calcium was 3.71 g/day, which is 17.8 percent of the total faecal calcium. The apparent and true digestibilities of Ca were calculated as 51 and 60 percent respectively. The endogenous faecal calcium can be estimated in buffalo calves by giving single subcutaneous injection of Ca 45 and collecting blood samples on 12th and 21st days only, and representative sample from the faeces collected from 13th through 22nd day after the injection. (author)

  16. Isotope dilution surface ionization mass spectrometry of silver in environmental materials

    Energy Technology Data Exchange (ETDEWEB)

    Murozumi, M; Nakamura, S; Suga, K [Muroran Inst. of Tech., Hokkaido (Japan)

    1981-03-01

    Surface ionization mass spectrometry has been developed to measure isotopic abundances and concentrations of silver in commercial high-purity metals, environmental materials such as rocks and plants, and /sup 109/Ag and /sup 107/Ag spikes. A minute amount of silver is extracted into a dithizone chloroform solution from a nitric acid solution of above samples. After the silver is back-extracted into 6.0 ml of a 7 mol/l HNO/sub 3/ solution, the solution is evaporated to dryness under the nitrogen atmosphere. Silver nitrate thus formed is dissolved in a mixture of 60 ..mu..l of an 0.003% silica gel suspended water and 5 ..mu..l of a 2% phosphoric acid. An aliquot of this solution is applied to the mass spectrometry using a rhenium single filament as an ion emitter. The proposed method can detect the presence of 10/sup -14/ g of silver on the ion emitter, and measure the /sup 109/Ag//sup 107/Ag isotopic ratio in environmental materials with the accuracy of 0.1 -- 0.2% in the coefficient of variation. Isotope dilution mass spectrometry using a /sup 107/Ag spike has revealed the silver concentration in the environmental standard materials, which were prepared by the National Bureau of Standards, U.S.A. and National Institute of Environmental Studies of Japan, as follows; 27.9 +- 0.2 ppb for the Orchard Leaves and 34.3 +- 0.3 ppb in the Pepper Bush. The determined values of silver in the Granodiorite, JG-1, and Basalt, JB-1 powders made by the Geological Survey of Japan are 25.4 +- 0.4 ppb and 41.3 +- 0.1 ppb respectively. Silver concentration in a coastal sea water sample is found to be at the level of 2.5 +- 0.4 ppt.

  17. Field experimentation in isotope-aided studies

    International Nuclear Information System (INIS)

    Zapata, F.

    1990-01-01

    Isotopic-aided studies involve the application of isotopically labelled fertilizer as tracers for the quantitative and precise determination of the fate of specific nutrient elements in the soil/plant system. The planning of isotopic-aided studies requires a different approach from that followed in the design of normal fertilizer trials because of the cost and supply of isotopically labelled materials, the use of highly specialized equipment and the need for skillful trained staff in the use of isotope techniques both in the field/greenhouse and the laboratory. This report is intended to highlight the main points to be considered while applying those techniques in the field or greenhouse. It has been well established that nuclear techniques are a powerful tool in agricultural research. One should take advantage of the use of such techniques if the following criteria are met: The isotope method is the only way to solve a particular question or to obtain a specific piece of information. There are other methods available for such a purpose but the nuclear method provides a direct and quick means to obtain the needed information resulting in higher economic return

  18. Determination of 240Pu/239Pu isotopic ratios in human tissues collected from areas around the Semipalatinsk Nuclear Test Site by sector-field high resolution ICP-MS.

    Science.gov (United States)

    Yamamoto, M; Oikawa, S; Sakaguchi, A; Tomita, J; Hoshi, M; Apsalikov, K N

    2008-09-01

    Information on the 240Pu/239Pu isotope ratios in human tissues for people living around the Semipalatinsk Nuclear Test Site (SNTS) was deduced from 9 sets of soft tissues and bones, and 23 other bone samples obtained by autopsy. Plutonium was radiochemically separated and purified, and plutonium isotopes (239Pu and 240Pu) were determined by sector-field high resolution inductively coupled plasma-mass spectrometry. For most of the tissue samples from the former nine subjects, low 240Pu/239Pu isotope ratios were determined: bone, 0.125 +/- 0.018 (0.113-0.145, n = 4); lungs, 0.063 +/- 0.010 (0.051-0.078, n = 5); and liver, 0.148 +/- 0.026 (0.104-0.189, n = 9). Only 239Pu was detected in the kidney samples; the amount of 240Pu was too small to be measured, probably due to the small size of samples analyzed. The mean 240Pu/239Pu isotope ratio for bone samples from the latter 23 subjects was 0.152 +/- 0.034, ranging from 0.088 to 0.207. A significant difference (a two-tailed Student's t test; 95% significant level, alpha = 0.05) between mean 240Pu/239Pu isotope ratios for the tissue samples and for the global fallout value (0.178 +/- 0.014) indicated that weapons-grade plutonium from the atomic bombs has been incorporated into the human tissues, especially lungs, in the residents living around the SNTS. The present 239,240Pu concentrations in bone, lung, and liver samples were, however, not much different from ranges found for human tissues from other countries that were due solely to global fallout during the 1970's-1980's.

  19. Determination of extremely low 236U/238U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction

    International Nuclear Information System (INIS)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2006-01-01

    A method by inductively coupled plasma mass spectrometry (Icp-Ms) was developed which allows the measurement of 236 U at concentration ranges down to 3 x 10 -14 g g -1 and extremely low 236 U/ 238 U isotope ratios in soil samples of 10 -7 . By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5000 counts fg -1 uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH + /U + down to a level of 10 -6 . An abundance sensitivity of 3 x 10 -7 was observed for 236 U/ 238 U isotope ratio measurements at mass resolution 4000. The detection limit for 236 U and the lowest detectable 236 U/ 238 U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the 236 U/ 238 U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the 235 U/ 238 U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of 236 U in the upper 0-10 cm soil layers varied from 2 x 10 -9 g g -1 within radioactive spots close to the Chernobyl NPP to 3 x 10 -13 g g -1 on a sampling site located by >200 km from Chernobyl

  20. Determination of extremely low (236)U/(238)U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction.

    Science.gov (United States)

    Boulyga, Sergei F; Heumann, Klaus G

    2006-01-01

    A method by inductively coupled plasma mass spectrometry (ICP-MS) was developed which allows the measurement of (236)U at concentration ranges down to 3 x 10(-14)g g(-1) and extremely low (236)U/(238)U isotope ratios in soil samples of 10(-7). By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5,000 counts fg(-1) uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH(+)/U(+) down to a level of 10(-6). An abundance sensitivity of 3 x 10(-7) was observed for (236)U/(238)U isotope ratio measurements at mass resolution 4000. The detection limit for (236)U and the lowest detectable (236)U/(238)U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the (236)U/(238)U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the (235)U/(238)U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of (236)U in the upper 0-10 cm soil layers varied from 2 x 10(-9)g g(-1) within radioactive spots close to the Chernobyl NPP to 3 x 10(-13)g g(-1) on a sampling site located by >200 km from Chernobyl.

  1. Validation of methods to measure uranium isotopes using magnetic sector mass spectrometry with inductively coupled plasma source; Validacion de metodos para medir isotopos de uranio usando espectrometria de masas de sector magnetico con fuente de plasma acoplado inductivamente

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, H. [Universidad del Centro de Mexico, Capitan Caldera 75, Col. Tequixquiapan, 78250 San Luis Potosi, SLP (Mexico); Rios L, M. J. [Universidad Autonoma de San Luis Potosi, Facultad de Enfermeria y Nutricion, Unidad de Posgrado, Av. Nino Artillero 130, 78210 San Luis Potosi, SLP (Mexico); Romero G, E. T., E-mail: hector.hernandez520@gmail.com [ININ, Departamento de Quimica, Laboratorio Forense Nuclear, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-10-15

    The mass spectrometry technique with inductively coupled plasma source (Icp-Ms) has been widely used to measure isotopic ratios of elements toxic to human health. Reason for which, in this work several measurement methods for the analysis of uranium isotopes in different matrices were implemented using magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). Groundwater, sediment, soil and urine were the matrices analyzed, which were supplied by intercomparison tests conducted by the IAEA and Association for the Promotion of Quality Control of Medical Biology Analysis in Radio-toxicology. The procedures used in the treatment of soil, sediment and water samples were based on US EPA methods. In the case of the urine sample, the preparation was rapid (1:20 dilution). The average of the results obtained in yield of each matrix was 94, 71, 72 and 78% for water, urine, soil and sediment respectively. In addition, the precision in terms of standard relative deviation was less than 5% and the accuracy was less than 4%. In conclusion, the Icp-SFMS is a very sensitive technique for measuring isotopes of U in different matrices. However, careful tuning is necessary, especially in the mass regions of interest 234, 235 and 238 if an external quantification is considered using natural U solutions. (Author)

  2. Isotope applications in the environmental field

    International Nuclear Information System (INIS)

    DeWitt, R.

    1978-01-01

    Established uses of enriched isotopes in the environmental field were surveyed to determine future trends in isotope needs. Based on established isotope uses, on the projected increase in the pollution problem, and on the apparent social and economic pressure for pollution abatement, a significant demand for enriched isotopes appears to be developing for the assessment and control of air, water, and soil pollutants. Isotopic techniques will be used in combination with conventional methods of detection and measurement, such as gas chromatography, x-ray fluorescence, and atomic absorption. Recent advances in economical isotope separation methods, instrumentation, and methodology promise to place isotopic technology within the reach of most research and industrial institutions. Increased application of isotope techniques appears most likely to occur in areas where data are needed to characterize the movement, behavior, and fate of pollutants in the environment

  3. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g{sup -1} levels

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Tibi, Markus; Heumann, Klaus G. [Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University Mainz, Duesbergweg 10-14, 55099, Mainz (Germany)

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3 x 10{sup -13} g g{sup -1} for Pu isotopes in soil samples containing uranium at a concentration of a few {mu}g g{sup -1}. The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH{sup +} and PbO{sub 2}{sup +} ions and by the peak tail of {sup 238}U{sup +} ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of {alpha}-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of {sup 239+240}Pu (9.8{+-}3.0 mBq g{sup -1}) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4{+-}0.2 mBq g{sup -1}. However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if ''hot'' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples. (orig.)

  4. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; West, C.E.; Breemen, R.B. van; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.; Lieshout, M. van; Russel, F.G.M.; Schaafsma, G.; Naber, A.H.J.

    2009-01-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted

  5. Odorant Screening and Quantitation of Thiols in Carmenere Red Wine by Gas Chromatography-Olfactometry and Stable Isotope Dilution Assays.

    Science.gov (United States)

    Pavez, Carolina; Agosin, Eduardo; Steinhaus, Martin

    2016-05-04

    The sensory impact of thiols in Vitis vinifera 'Carmenere' red wines was evaluated. For this purpose, aroma extract dilution analysis was applied to the thiols isolated from a Carmenere red wine by affinity chromatography with a mercurated agarose gel. Results revealed the presence of four odorants, identified as 2-furanylmethanethiol, 3-sulfanylhexyl acetate, 3-sulfanyl-1-hexanol, and 2-methyl-3-sulfanyl-1-butanol, with the latter being described here for the first time in Carmenere red wines. Quantitation of the four thiols in the Carmenere wine screened by aroma extract dilution analysis and in three additional Carmenere wines by stable isotope dilution assays resulted in concentrations above the respective orthonasal odor detection threshold values. Triangle tests applied to wine model solutions with and without the addition of the four thiols showed significant differences, thus suggesting that the compounds do have the potential to influence the overall aroma of red wine.

  6. Application of double-spike isotope dilution for the accurate determination of Cr(III), Cr(VI) and total Cr in yeast.

    Science.gov (United States)

    Yang, Lu; Ciceri, Elena; Mester, Zoltán; Sturgeon, Ralph E

    2006-11-01

    A method is presented for the simultaneous determination of Cr(III) and Cr(VI) in yeast using species-specific double-spike isotope dilution (SSDSID) with anion-exchange liquid chromatography (LC) separation and sector field inductively coupled plasma mass spectrometric (SF-ICP-MS) detection. Total Cr is quantitated using ID SF-ICP-MS. Samples were digested on a hot plate at 95+/-2 degrees C for 6 h in an alkaline solution of 0.5 M NaOH and 0.28 M Na2CO3 for the determination of Cr(III) and Cr(VI), whereas microwave-assisted decomposition with HNO3 and H2O2 was used for the determination of total Cr. Concentrations of 2,014+/-16, 1,952+/-103 and 76+/-48 mg kg-1 (one standard deviation, n=4, 3, 3), respectively were obtained for total Cr, Cr(III) and Cr(VI) in the yeast sample. Significant oxidation of Cr(III) to Cr(VI) (24.2+/-7.6% Cr(III) oxidized, n=3) and reduction of Cr(VI) to Cr(III) (37.6+/-6.5% Cr(VI) reduced, n=3) occurred during alkaline extraction and subsequent chromatographic separation at pH 7. Despite this significant bidirectional redox transformation, quantitative recoveries for both Cr(III) and Cr(VI) were achieved using the SSDSID method. In addition, mass balance between total Cr and the sum of Cr(III) and Cr(VI) concentrations was achieved. Method detection limits of 0.3, 2 and 30 mg kg-1 were obtained for total Cr, Cr(VI) and Cr(III), respectively, based on a 0.2-g sub-sample.

  7. Research trend survey on the stable isotope utilization technology; Antei doitai no riyo gijutsu ni kansuru kenkyu doko chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This report reviews the activities and the trends in the area of the stable isotope use attracting attention recently. In the medicine and clinical treatment sector, the remarkable trends are the extension of {sup 13}C use. The breath test and the magnetic resonance spectroscopy (MRS) diagnosis have been developed as inspection methods. It is noted that investigation has been initiated on the magnetic resonance imaging (MRI) using {sup 3}He and {sup 129}Xe for the lung imaging. In the organic chemistry and biochemistry sector, the stable isotopes are used for analyzing the structures of complicated natural compounds and materials relating to life science and for analyzing the chemical reaction mechanism of organic compounds. In the nuclear energy sector, {sup 10}B and {sup 7}Li have been used as neutron absorption materials and pH neutralizing reagent, respectively. In the analysis and measurement sector, the process of isotopic dilution is used for the environmental analysis of trace elements including harmful substances. Among various separation methods of isotopes, well studied uranium enrichment processes and deuterium separation processes are described. Separation of {sup 15}N by ion exchange resin method and plasma ion cyclotron resonance (ICR) isotope separation have been studied, recently. 133 refs., 53 figs., 7 tabs.

  8. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    Science.gov (United States)

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8

  9. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition.

    Science.gov (United States)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita; Friis, Henrik; Kurpad, Anura; Wells, Jonathan C

    2017-08-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work to develop and adapt the deuterium dilution technique. We refined procedures for administration of isotope doses and collection of saliva. Furthermore, we established that equilibration time in local context is 3 h. These findings and the resulting standard operating procedures are important to improve data quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques.

  10. Quantitative Analysis of Ingenol in Euphorbia species via Validated Isotope Dilution Ultra-high Performance Liquid Chromatography Tandem Mass Spectrometry

    Czech Academy of Sciences Publication Activity Database

    Béres, T.; Dragull, K.; Pospíšil, Jiří; Tarkowská, Danuše; Dančák, M.; Bíba, Ondřej; Tarkowski, P.; Doležal, K.; Strnad, Miroslav

    2018-01-01

    Roč. 29, č. 1 (2018), s. 23-29 ISSN 0958-0344 R&D Projects: GA ČR GA17-14007S; GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Euphorbia genus * ingenol * isotope-dilution method * mass spectrometry * ultra-high performance liquid chromatography Subject RIV: FD - Oncology ; Hematology OBOR OECD: Analytical chemistry Impact factor: 2.292, year: 2016

  11. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  12. Sm isotope composition and Sm/Eu ratio determination in an irradiated 153Eu sample by ion exchange chromatography-quadrupole inductively coupled plasma mass spectrometry combined with double spike isotope dilution technique

    International Nuclear Information System (INIS)

    Bourgeois, M.; Isnard, H.; Gourgiotis, A.; Stadelmann, G.; Gautier, C.; Mialle, S.; Nonell, A.; Chartier, F.

    2011-01-01

    Within the framework of the research undertaken by the French Atomic Energy Commission on transmutation of long-lived radionuclides, targets of highly enriched actinides and fission products were irradiated in the fast neutron reactor Phenix. Precise and accurate measurements of the isotopic and elemental composition of the enriched elements are therefore required. In order to obtain the uncertainties of several per mil and to reduce handling time and exposure to analyst on radioactive material, the on-line coupling of ion exchange chromatography with quadrupole inductively coupled plasma mass spectrometry has been associated with the technique of the double spike isotope dilution. We present in this paper the results obtained on an irradiated sample of Europium oxide powder (enriched at 99.13% in 153 Eu). After irradiation of around 5 mg of Eu 2 O 3 powder the theoretical calculations predict the formation of several micrograms of gadolinium and samarium isotopes. In relation to the very high activity of the sample after irradiation and the very low quantity of Sm formed, the on-line ion exchange chromatography separation of Gd, Sm and Eu before Sm isotope ratio measurements has been developed for the quantification of the 152 Sm/ 153 Eu ratio. These on-line measurements were associated with the double spike isotope dilution technique after calibration of a 147 Sm/ 151 Eu spike solution. The external reproducibility of Sm isotopic ratios was determined to be around 0.5% (2 σ) resulting in a final uncertainty on the 152 Sm/ 153 Eu ratio of around 1% (2 σ). These on-line measurements present therefore a robust and high-throughput alternative to the thermal-ionisation mass spectrometry technique used so far in combination with off-line chromatographic separation, particularly in nuclear applications where characterisation of high activity sample solutions is required. (authors)

  13. Field Sample Preparation Method Development for Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    Leibman, C.; Weisbrod, K.; Yoshida, T.

    2015-01-01

    Non-proliferation and International Security (NA-241) established a working group of researchers from Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to evaluate the utilization of in-field mass spectrometry for safeguards applications. The survey of commercial off-the-shelf (COTS) mass spectrometers (MS) revealed no instrumentation existed capable of meeting all the potential safeguards requirements for performance, portability, and ease of use. Additionally, fieldable instruments are unlikely to meet the International Target Values (ITVs) for accuracy and precision for isotope ratio measurements achieved with laboratory methods. The major gaps identified for in-field actinide isotope ratio analysis were in the areas of: 1. sample preparation and/or sample introduction, 2. size reduction of mass analyzers and ionization sources, 3. system automation, and 4. decreased system cost. Development work in 2 through 4, numerated above continues, in the private and public sector. LANL is focusing on developing sample preparation/sample introduction methods for use with the different sample types anticipated for safeguard applications. Addressing sample handling and sample preparation methods for MS analysis will enable use of new MS instrumentation as it becomes commercially available. As one example, we have developed a rapid, sample preparation method for dissolution of uranium and plutonium oxides using ammonium bifluoride (ABF). ABF is a significantly safer and faster alternative to digestion with boiling combinations of highly concentrated mineral acids. Actinides digested with ABF yield fluorides, which can then be analyzed directly or chemically converted and separated using established column chromatography techniques as needed prior to isotope analysis. The reagent volumes and the sample processing steps associated with ABF sample digestion lend themselves to automation and field

  14. Investigating Pu and U isotopic compositions in sediments: a case study in Lake Obuchi, Rokkasho Village, Japan using sector-field ICP-MS and ICP-QMS.

    Science.gov (United States)

    Zheng, Jian; Yamada, Masatoshi

    2005-08-01

    The objectives of the present work were to study isotope ratios and the inventory of plutonium and uranium isotope compositions in sediments from Lake Obuchi, which is in the vicinity of several nuclear fuel facilities in Rokkasho, Japan. Pu and its isotopes were determined using sector-field ICP-MS and U and its isotopes were determined with ICP-QMS after separation and purification with a combination of ion-exchange and extraction chromatography. The observed (240)Pu/(239)Pu atom ratio (0.186 +/- 0.016) was similar to that of global fallout, indicating that the possible early tropospheric fallout Pu did not deliver Pu from the Pacific Proving Ground to areas above 40 degrees N. The previously reported higher Pu inventory in the deep water area of Lake Obuchi could be attributed to the lateral transportation of Pu deposited in the shallow area which resulted from the migration of deposited global fallout Pu from the land into the lake by river runoff and from the Pacific Ocean by tide movement and sea water scavenging, as well as from direct soil input by winds. The (235)U/(238)U atom ratios ranged from 0.00723 to 0.00732, indicating the natural origin of U in the sediments. The average (234)U/(238)U activity ratio of 1.11 in a sediment core indicated a significant sea water U contribution. No evidence was found for the release of U containing wastes from the nearby nuclear facilities. These results will serve as a reference baseline on the levels of Pu and U in the studied site so that any further contamination from the spent nuclear fuel reprocessing plants, the radioactive waste disposal and storage facilities, and the uranium enrichment plant can be identified, and the impact of future release can be rapidly assessed.

  15. Multi-isotopic determination of plutonium (239Pu, 240Pu, 241Pu and 242Pu) in marine sediments using sector-field inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Donard, O F X; Bruneau, F; Moldovan, M; Garraud, H; Epov, V N; Boust, D

    2007-03-28

    Among the transuranic elements present in the environment, plutonium isotopes are mainly attached to particles, and therefore they present a great interest for the study and modelling of particle transport in the marine environment. Except in the close vicinity of industrial sources, plutonium concentration in marine sediments is very low (from 10(-4) ng kg(-1) for (241)Pu to 10 ng kg(-1) for (239)Pu), and therefore the measurement of (238)Pu, (239)Pu, (240)Pu, (241)Pu and (242)Pu in sediments at such concentration level requires the use of very sensitive techniques. Moreover, sediment matrix contains huge amounts of mineral species, uranium and organic substances that must be removed before the determination of plutonium isotopes. Hence, an efficient sample preparation step is necessary prior to analysis. Within this work, a chemical procedure for the extraction, purification and pre-concentration of plutonium from marine sediments prior to sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) analysis has been optimized. The analytical method developed yields a pre-concentrated solution of plutonium from which (238)U and (241)Am have been removed, and which is suitable for the direct and simultaneous measurement of (239)Pu, (240)Pu, (241)Pu and (242)Pu by SF-ICP-MS.

  16. Vitamin A equivalency of ß-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect

    NARCIS (Netherlands)

    Bouwman, C.A.; West, C.E.; Breemen, van R.B.; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.M.; Lieshout, van M.; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.J.

    2009-01-01

    Data on the vitamin A equivalency of ß-carotene in food are inconsistent. We quantified the vitamin A equivalency (¿g) of ß-carotene in two diets using the dual-isotope dilution technique and the oral¿faecal balance technique. A diet-controlled, cross-over intervention study was conducted in

  17. Isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) for the certification of lead and cadmium in environmental standard reference materials.

    Science.gov (United States)

    Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D

    2000-10-01

    Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.

  18. Determination of Trace Iron in Red Wine by Isotope Dilution Mass Spectrometry Using Multiple-Collector Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Zhou Tao; Wang Jun; Lu Hai; Zhou Yuanjing; Li Haifeng

    2009-01-01

    This paper introduces determination of trace iron in red wine certified reference material by isotope dilution mass spectrometry (IDMS) method using a multiplecollector inductively coupled plasma mass spectrometry, equipped with a hexapole collision cell. The measurement procedure of iron isotopic abundance ratios was deeply researched. Reduced polyatomic ion interferences to iron isotopes ion by collision reaction using Ar and H 2 gas, high precise isotopic abundance ratios were achieved. Two relative measurement methods (ICP-MS and ICP-OES) were used to analyze trace iron in red wine. The results are compared with IDMS results, which indicate that they are accordant. The uncertainty analyses include each uncertainty factor in whole experiment and the uncertainty of used certified reference material and it shows that the procedure blank is not neglectable to detect limit and precision of the method. The establishment of IDMS method for analysis of trace iron in red wine supports the certification of certified reference materials. (authors)

  19. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  20. The relation of plasma octopamine to hepatic encephalopathy studied with stable isotope dilution technique

    International Nuclear Information System (INIS)

    Zhang Jianhua

    1992-01-01

    In order to investigate the relationship between octopamine and hepatic encephalopathy, plasma octopamine content of normal adults and hepatic patients (compensated or de-compensated cirrhotic, patients with encephalopathy) were determined with isotope dilution and GCMS technique, 200 ng of [1, 1-D]-octopamine was added to each sample as internal standard. After the de-proteinized plasma was subjected to cation exchange chromatography, the amine fraction was derivatized with PFP and analyzed with GCMS using the selected ion monitoring technique. The result showed that the level of plasma octopamine was significantly elevated in patients with encephalopathy. Since this method is sensitive and specific, it is readily applicable to the analysis of a few nano grams of octopamine

  1. Development of procedure for measurement of Pb isotope ratios in seawater by application of seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Vassileva, Emilia; Wysocka, Irena

    2016-12-01

    Anthropogenic Pb in the oceans, derived from high-temperature industrial processes, fuel combustion and incineration can have an isotopic signature distinct from naturally occurring Pb, supplied by rock weathering. To identify the different pollution sources accurately and to quantify their relative contributions, Pb isotope ratios are widely used. Due to the high salt content (approximately 3.5% of total dissolved solids) and very low levels of Pb (typically from 1 to 100 ng L- 1) in seawater the determination of Pb isotope ratios requires preliminary matrix separation and analyte preconcentration. An analytical protocol for the measurements of Pb isotope ratios in seawater combining seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry (SF ICP-MS) was developed. The application of seaFAST system was advantageous, because of its completely closed working cycle and small volumes of chemicals introduced in pre-treatment step, resulting in very low detection limits and procedural blanks. The preconcentration/matrix separation step was also of crucial importance for minimizing the isobaric and matrix interferences, coming from the seawater. In order to differentiate between anthropogenic and natural Pb sources, particular attention was paid to the determination of 204Pb isotope because of its implication in some geological interpretations. The validation of the analytical procedure was effectuated according to the recommendations of the ISO/IEC 17025 standard. The method was validated by processing the common Pb isotope reference material NIST SRM 981. All major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. The estimation of the total uncertainty associated to each measurement result was fundamental tool for sorting the main sources of possible biases. The developed analytical procedure was applied to the coastal and open seawater samples, collected in different regions of

  2. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  3. The use of the 15N isotope dilution technique to estimate the contribution of associated biological nitrogen fixation to the nitrogen nutrition of Paspalum notatum cv. batatais

    International Nuclear Information System (INIS)

    Boddey, R.M.; Doebereiner, Johanna

    1983-01-01

    This paper reports the results of a field experiment to investigate the use of the 15 N-dilution technique to measure the contribution of biological N 2 fixation to the N nutrition of the batatais cultivar of Paspalum notatum. The pensacola cultivar of this grass supports little associated N 2 fixation as evidenced by the low associated C 2 H 2 reduction activity and was thus used as a nonfixing control plant. The grasses were grown in 60-cm diameter concrete cylinders sunk into the soil, and the effects of four different addition rates of labelled nitrogen (NH 4 ) 2 SO 4 , were investigated. The data from seven harvests clearly demonstrated that there was a significant input of plant associated N 2 fixation to the nutrition of the batatais cultivar amounting to approximately 20 kg N ha -1 year -1 . Problems associated with the conduct of such isotope dilution experiments are discussed including the importance of using nonfixing control plants of similar growth habit, the advantages and disadvantages of growing the plants in cylinders as opposed to field plots, and the various methods of application of labelled N fertilizer

  4. Investigation of mercury-containing proteins by enriched stable isotopic tracer and size-exclusion chromatography hyphenated to inductively coupled plasma-isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shi Junwen [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Feng Weiyue [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]. E-mail: fengwy@mail.ihep.ac.cn; Wang Meng [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Zhang Fang [Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Li Bai [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Wang Bing; Zhu Motao [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Chai Zhifang [Laboratory for Bio-Environmental Health Sciences of Nanoscale Materials and Key Laboratory of Nuclear Analytical Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)]|[Institute of Nuclear Technology, Shenzhen University, Shenzhen 518060 (China)]|[Institute of Nanochemistry and Nanosafety, Shanghai University, Shanghai (China)

    2007-01-30

    In order to investigate trace mercury-containing proteins in maternal rat and their offspring, a method of enriched stable isotopic tracer ({sup 196}Hg and {sup 198}Hg) combined with size-exclusion chromatography (SEC) coupled to inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) was developed. Prior to the analysis, {sup 196}Hg- and {sup 198}Hg-enriched methylmercury was administrated to the pregnant rats. Then the mercury-containing proteins in serum and brain cytosol of the dam and pup rats were separated by size-exclusion columns and the mercury was detected by ICP-MS. The ICP-MS spectrogram of the tracing samples showed significantly elevated {sup 196}Hg and {sup 198}Hg isotopic signals compared with the natural ones, indicating that the detection sensitivity could be increased by the tracer method. The contents of mercury in chromatographic fractions of the dam and pup rat brain cytosol were quantitatively estimated by post-column reverse ID-ICP-MS. The quantitative speciation differences of mercury in brain cytosol between the dam and pup rats were observed, indicating that such studies could be useful for toxicological estimation. Additionally, the isotopic ratio measurement of {sup 198}Hg/{sup 202}Hg in the tracing samples could be used to identify the artifact mercury species caused in the analytical procedure. The study demonstrates that the tracer method combined with high-performance liquid chromatography (HPLC)-ICP-IDMS could provide reliably qualitative and quantitative information on mercury-containing proteins in organisms.

  5. Investigation of mercury-containing proteins by enriched stable isotopic tracer and size-exclusion chromatography hyphenated to inductively coupled plasma-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Shi Junwen; Feng Weiyue; Wang Meng; Zhang Fang; Li Bai; Wang Bing; Zhu Motao; Chai Zhifang

    2007-01-01

    In order to investigate trace mercury-containing proteins in maternal rat and their offspring, a method of enriched stable isotopic tracer ( 196 Hg and 198 Hg) combined with size-exclusion chromatography (SEC) coupled to inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) was developed. Prior to the analysis, 196 Hg- and 198 Hg-enriched methylmercury was administrated to the pregnant rats. Then the mercury-containing proteins in serum and brain cytosol of the dam and pup rats were separated by size-exclusion columns and the mercury was detected by ICP-MS. The ICP-MS spectrogram of the tracing samples showed significantly elevated 196 Hg and 198 Hg isotopic signals compared with the natural ones, indicating that the detection sensitivity could be increased by the tracer method. The contents of mercury in chromatographic fractions of the dam and pup rat brain cytosol were quantitatively estimated by post-column reverse ID-ICP-MS. The quantitative speciation differences of mercury in brain cytosol between the dam and pup rats were observed, indicating that such studies could be useful for toxicological estimation. Additionally, the isotopic ratio measurement of 198 Hg/ 202 Hg in the tracing samples could be used to identify the artifact mercury species caused in the analytical procedure. The study demonstrates that the tracer method combined with high-performance liquid chromatography (HPLC)-ICP-IDMS could provide reliably qualitative and quantitative information on mercury-containing proteins in organisms

  6. Determination of micro-quantities of several elements in soil solution by isotope dilution and activation analyses

    International Nuclear Information System (INIS)

    Cho, C.M.; Axmann, H.

    1965-01-01

    Determination of small quantities of plant nutrients in the soil solution of flooded rice soils is a difficult problem. The concentrations of Mn, Fe and P, for example, in some soil solutions are so small that no chemical method gives any accurate result. Neutron activation analysis was reported to give a much lower limit of detectability for several elements, while for elements with low-induced activity after neutron irradiation, substoichiometric isotopic dilution analysis was applied. One of the advantages of neutron activation analysis lies in the fact that simultaneous activation of every inducible element in a sample takes place. This gives an opportunity to determine many elements by one sample preparation and irradiation. This, however, is not a simple task since identification of the activated products and their quantitative estimation becomes very difficult. Certain operations of separation must be carried out before activity measurements. Ion-exchange resin columns and chemical separation following the addition of carriers were successfully used for the determination of many elements after neutron irradiation. These procedures, however, cannot be directly applied to the determination of the elements of agronomic interest. A procedure was developed to determine several elements of agronomic interest. Times of irradiation and cooling, quick separation by ion-exchange columns, together with chemical precipitation for β-emitters of relatively long half-lives, were all combined to get the maximum benefit from neutron activation analysis. For Fe, for which no satisfactory neutron activation analysis has yet been developed, a modified substoichiometric double isotope dilution procedure is applied

  7. Formic acid hydrolysis/liquid chromatography isotope dilution mass spectrometry: An accurate method for large DNA quantification.

    Science.gov (United States)

    Shibayama, Sachie; Fujii, Shin-Ichiro; Inagaki, Kazumi; Yamazaki, Taichi; Takatsu, Akiko

    2016-10-14

    Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) with formic acid hydrolysis was established for the accurate quantification of λDNA. The over-decomposition of nucleobases in formic acid hydrolysis was restricted by optimizing the reaction temperature and the reaction time, and accurately corrected by using deoxynucleotides (dNMPs) and isotope-labeled dNMPs as the calibrator and the internal standard, respectively. The present method could quantify λDNA with an expanded uncertainty of 4.6% using 10fmol of λDNA. The analytical results obtained with the present method were validated by comparing with the results of phosphate-base quantification by inductively coupled plasma-mass spectrometry (ICP-MS). The results showed good agreement with each other. We conclude that the formic acid hydrolysis/LC-IDMS method can quantify λDNA accurately and is promising as the primary method for the certification of DNA as reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Polar cap geomagnetic field responses to solar sector changes

    International Nuclear Information System (INIS)

    Campbell, W.H.

    1976-01-01

    I made a computerized analysis of digitized magnetograms from Alert, Thule, Resolute Bay, Mould Bay, and Godhavn for 1965 and from Thule and Vostok for 1967 to determine the characteristic features of the day-to-day geomagnetic field variations related to the interplanetary solar sector field direction. Higher invariant latitude stations showed the sector effects most clearly. A sector-related phase shift in the characteristic diurnal variation of the field occurred principally for the dayside vertical geomagnetic component. The amplitude of this diurnal variation was related to Ap and could not be used to identify the sector direction. The quiet nighttime level of field Z component rose and fell on days when the interplanetary magnetic field was directed toward or away from the sun, respectively. When a station's base level field was determined from quiet magnetospheric conditions by using days with low values of Dst and AE indices, the mean field level of the Z component for the whole day increased or decreased (often over 100 γ) from this level as the solar sector direction was toward or away, respectively. With respect to the earth's main field direction the souther polar station field level changes were opposite those at the northern stations. This level shift corresponded with the two solar field directions during the summer months at polar stations for about 70% of the days in 1965 and 88% of the days in 1967. In 1967 the standoff locations of the magnetopause and magnetoshock boundaries were abotu 1 R/sub E/ more distant from the earth for the average toward sector days than for the away sector days

  9. Determination of extremely low {sup 236}U/{sup 238}U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F. [Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University Mainz, Duesbergweg 10-14, 55099 Mainz (Germany)]. E-mail: sergei.boulyga@univie.ac.at; Heumann, Klaus G. [Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University Mainz, Duesbergweg 10-14, 55099 Mainz (Germany)

    2006-07-01

    A method by inductively coupled plasma mass spectrometry (Icp-Ms) was developed which allows the measurement of {sup 236}U at concentration ranges down to 3 x 10{sup -14} g g{sup -1} and extremely low {sup 236}U/{sup 238}U isotope ratios in soil samples of 10{sup -7}. By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5000 counts fg{sup -1} uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH{sup +}/U{sup +} down to a level of 10{sup -6}. An abundance sensitivity of 3 x 10{sup -7} was observed for {sup 236}U/{sup 238}U isotope ratio measurements at mass resolution 4000. The detection limit for {sup 236}U and the lowest detectable {sup 236}U/{sup 238}U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the {sup 236}U/{sup 238}U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the {sup 235}U/{sup 238}U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of {sup 236}U in the upper 0-10 cm soil layers varied from 2 x 10{sup -9} g g{sup -1} within radioactive spots close to the Chernobyl NPP to 3 x 10{sup -13} g g{sup -1} on a sampling site located by >200 km from Chernobyl.

  10. Determination of sulfur in steels by isotope dilution mass spectrometry after dissolution with sealed tube

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1981-01-01

    The scaled tube dissolution technique was studied for the complete conversion of sulfur in steels to sulfate. Isotope dilution mass spectrometry was used for the determination of sulfur in the sulfate. Sample (0.5 g) was dissolved in nitric acid (7 ml) and hydrochloric acid (3 ml) in a scaled borosilicate glass tube on being heated above 180 0 C overnight. Nitrate ions were removed by repeated evaporation with hydrochloric acid. The residue was dissolved in hydrochloric acid. Sulfate was reduced with a mixture of hydrochloric, hydroiodic and hypophosphorous acids; hydrogen sulfide evolved was absorbed in cadmium acetate solution, then converted to silver sulfide, which was burned to sulfur dioxide in pure oxygen at low pressure, for isotopic analysis. Analytical blank in whole procedure was 0.8 μg of sulfur. This technique was applied to the determination of sulfur in NBS low alloy steels. The principal cause of low values obtained by the open beaker dissolution technique was evaporation losses of sulfur as sulfur dioxide during the dissolution. (author)

  11. ISOTOPE-DILUTION AMMONIA CHEMICAL-IONIZATION MASS FRAGMENTOGRAPHIC ANALYSIS OF URINARY 3-O-METHYLATED CATECHOLAMINE METABOLITES - RAPID SAMPLE CLEANUP BY DERIVATIZATION AND EXTRACTION OF LYOPHILIZED SAMPLES

    NARCIS (Netherlands)

    KEMA, IP; MEIBORG, G; NAGEL, GT; STOB, GJ; MUSKIET, FAJ

    1993-01-01

    We developed a method for simultaneous quantification of the urinary 3-O-methylated catecholamine metabolites 3-methoxytyramine, normetanephrine and metanephrine by stable isotope-dilution ammonia chemical ionization mass fragmentography. Prepurification of lyophilized samples was done by

  12. Mass spectrometric isotope dilution analyses of palladium, silver, cadmium and tellurium in carbonaceous chondrites

    International Nuclear Information System (INIS)

    Loss, R.D.; Rosman, K.J.R.; De Laeter, J.

    1984-01-01

    The mass spectrometric isotope dilution technique was used to measure the elemental abundances of Pd, Ag, Cd and Te in Orgueil (C1), Ivuna (C1), Murray (C2) and Allende (C3) chondrites. The Pd abundance of 554 ppb for the Cl chondrites is almost identical to the recommended value of Anders and Ebihara (1982); that for Cd (712 ppb) is approximately 5% higher, whereas that for Ag (198 ppb) is approximately 10% lower than the recommended values. A smooth distribution for the abundances of the odd-A nuclides between 65 128 Te and 130 Te to lie approximately 30% above the r-process peak at A = 130, whereas the new value fits smoothly into the general trend. (author)

  13. Uses of stable isotopes

    International Nuclear Information System (INIS)

    Axente, Damian

    1998-01-01

    The most important fields of stable isotope use with examples are presented. These are: 1. Isotope dilution analysis: trace analysis, measurements of volumes and masses; 2. Stable isotopes as tracers: transport phenomena, environmental studies, agricultural research, authentication of products and objects, archaeometry, studies of reaction mechanisms, structure and function determination of complex biological entities, studies of metabolism, breath test for diagnostic; 3. Isotope equilibrium effects: measurement of equilibrium effects, investigation of equilibrium conditions, mechanism of drug action, study of natural processes, water cycle, temperature measurements; 4. Stable isotope for advanced nuclear reactors: uranium nitride with 15 N as nuclear fuel, 157 Gd for reactor control. In spite of some difficulties of stable isotope use, particularly related to the analytical techniques, which are slow and expensive, the number of papers reporting on this subject is steadily growing as well as the number of scientific meetings organized by International Isotope Section and IAEA, Gordon Conferences, and regional meeting in Germany, France, etc. Stable isotope application development on large scale is determined by improving their production technologies as well as those of labeled compound and the analytical techniques. (author)

  14. The study on effect of zeolite on nitrogen use efficiency of corn by 15N-isotope dilution method

    International Nuclear Information System (INIS)

    Li Changhong; Li Huaxing; Zhang Xinming; Liu Yuanjin

    2002-01-01

    A pot experiment was carried out to study the effect of natural zeolite on nitrogen use efficiency of corn by using 15 N-isotope dilution method. The results showed that application of zeolite could improve the corn growth and enhance the biomass of the corn seedling. By using zeolite, nitrogen use efficiency (NUE) of corn was increased by 23.2%-33.1% as compared with no-zeolite treatment; and the residual nitrogen has no significant difference between zeolite treatment and no-zeolite treatment

  15. Urinary oxalate excretion, as determined by isotope dilution and indirect colorimetry

    International Nuclear Information System (INIS)

    Prenen, J.A.C.; Boer, P.; Leersum, L. van; Oldenburg, S.J.; Endeman, H.J.

    1983-01-01

    A simple and reliable method for the determination of urinary oxalate excretion is described. Urinary oxalate is precipitated with calcium chloride, and the oxalate content of the precipitate is measured by an indirect colorimetric method developed by Neas and Guyon in 1972. For single urine samples, a correction is made for the incompleteness of the precipitation of calcium oxalate by isotope dilution. The range of normal values (5% limits) determined in 52 normal subjects was 0.121-0.325 mmol.24 h - 1 .m - 2 for a 1-day collection period and 0.145-0.301 mmol. 24 h - 1 .m - 2 for a 3-day collection period. The within-assay CV of a control urine with a low oxalate concentration was 9% (n=7) and the between-assay CV for the same control urine was 12% (n=6). When the values obtained for oxalate excretion were normalized to body surface area, there was no significant difference between males and females; the main source of variation was the intra-individual variation. (Auth.)

  16. Experimental substantiation of separation techniques of lead and uranium microamounts using isotopic dilution method as control method

    International Nuclear Information System (INIS)

    Agapova, A.A.; Shcherbinina, N.K.

    1983-01-01

    Methods,ensuring at low levels of contamination a high degree of lead and uranium microamount separation from solutions of geological samples, have been selected and subjected to the detailed testing. The method of isotope dilution, , combining high accuracy and sensitivity of determinations, is used as the main control methods, is used as the main control method. Using the method, processe es of uranium extpaction are traced, special attention is paid to the detailed description of lead extraction at all the stages of the methods selected. Opera ations of ion exchange for lead and uranium in microcolumns with the Bio-Rad r sin are considered, as well as operations of lead electrolytic separation. The chemical procedures suggested permit to solve one of the main methodical tasks f sample preparation, containing microgram amounts of lead and uranium, for high h-prcision measurement of their isotope composition using mass-spectrometric method

  17. Development of a mass spectrometrical isotope dilution analysis for determination of trace iodine levels and its application for food samples

    International Nuclear Information System (INIS)

    Schindlmeier, W.

    1984-01-01

    A mass spectrometrical isotope dilution procedure for the determination of trace amounts of iodine in various materials was developed using 129 I as indicator isotope, based on the determination of the 129 I/ 127 I isotope relationship. Negative thermionization was used as ionization method. The analysis procedure, which worked with a standard deviation of between 0,1 and 10% (depending on material tested), was used to determine the iodine level of table salt - both iodized and normal salt (3-6 ppm and less than 0,006 ppm respectively), and food samples with an organic matrix. For comparison the iodine levels were also measured with an iodine-selective electrode. Special preparation and separation procedures were done to suit the sample material. A comparison of the levels of iodine concentration in various powdered milks which were measured by international collaborators using varying methods shows the superior reproducibility of the MS-IDA. (RB) [de

  18. Isotope hydrology: A historical overview of achievements

    International Nuclear Information System (INIS)

    1997-01-01

    The IAEA's efforts in the water sector cover all aspects of the three main categories of isotope methodologies, such as the use of radioactive isotopes as tracers for site-specific investigations related to water movement; the use of sealed radioactive sources for in-situ measurement of hydrological field parameters; and the use of naturally occurring isotopic species for the assessment and study of water occurrence, genesis and flow pathways/dynamics at regional-scale hydrological systems

  19. Filling the gap in Ca input-output budgets in base-poor forest ecosystems: The contribution of non-crystalline phases evidenced by stable isotopic dilution

    Science.gov (United States)

    van der Heijden, Gregory; Legout, Arnaud; Mareschal, Louis; Ranger, Jacques; Dambrine, Etienne

    2017-07-01

    In terrestrial ecosystems, plant-available pools of magnesium and calcium are assumed to be stored in the soil as exchangeable cations adsorbed on the surface of mineral and/or organic particles. The pools of exchangeable magnesium and calcium are measured by ion-exchange soil extractions. These pools are sustained in the long term by the weathering of primary minerals in the soil and atmospheric inputs. This conceptual model is the base of input-output budgets from which soil acidification and the sustainability of soil chemical fertility is inferred. However, this model has been questioned by data from long-term forest ecosystem monitoring sites, particularly for calcium. Quantifying the contribution of atmospheric inputs, ion exchange and weathering of both primary, secondary and non-crystalline phases to tree nutrition in the short term is challenging. In this study, we developed and applied a novel isotopic dilution technique using the stable isotopes of magnesium and calcium to study the contribution of the different soil phases to soil solution chemistry in a very acidic soil. The labile pools of Mg and Ca in the soil (pools in equilibrium with the soil solution) were isotopically labeled by spraying a solution enriched in 26Mg and 44Ca on the soil. Labeled soil columns were then percolated with a dilute acid solution during a 3-month period and the isotopic dilution of the tracers was monitored in the leaching solution, in the exchangeable (2 sequential 1 mol L-1 ammonium acetate extractions) and non-crystalline (2 sequential soil digestions: oxalic acid followed by nitric acid) phases. Significant amounts of Mg and Ca isotope tracer were recovered in the non-crystalline soil phases. These phases represented from 5% to 25% and from 24% to 50%, respectively, of the Mg and Ca labile pools during the experiment. Our results show that non-crystalline phases act as both a source and a sink of calcium and magnesium in the soil, and contribute directly to soil

  20. Isotopically exchangeable phosphorus

    International Nuclear Information System (INIS)

    Barbaro, N.O.

    1984-01-01

    A critique revision of isotope dilution is presented. The concepts and use of exchangeable phosphorus, the phosphate adsorption, the kinetics of isotopic exchange and the equilibrium time in soils are discussed. (M.A.C.) [pt

  1. Agronomic behavior of phosphoric rock from Bahia Inglesa using isotopic techniques. 1. Field trial with concentrated and non concentrated rock

    International Nuclear Information System (INIS)

    Pino N, I.; Casa G, L.

    1989-01-01

    With the aim to assess the agronomic behaviour of the phosphoric rock from Bahia Inglesa, a field trial was carried out with concentrated and non concentrated 100 mesh sieved rock. The method of isotopic dilution was used with TSP labeled P32 (TSP-P32) as standard fertilizer. Total dry matter, total P by colorimetry and P32 by liquid scintillation using the Cerenkov effect were measured. Both agronomic and isotope parameters were analyzed. The concentrated phosphoric rock was 3.7 times better than the same non concentrated rock. These also was a positive effect from non concentrated at 400 kg P205/ha dose. This effect was attributed to a higher saturation in the points of P sorption. The TSP showed a better behaviour than the phosphoric rock under study. (author)

  2. Applicability of isotopic dilution methods for determination of the zinc supplying capacity of some Indian soils

    International Nuclear Information System (INIS)

    Iyengar, B.R.V.; Deb, D.L.

    1975-01-01

    The applicability of the isotopic dilution methods to determine the zinc supplying capacity of some Indian soils belonging to three soil groups was studied using 65 Zn. In these soils 'L' values determined by the pot culture method and the 'E' values by equilibration in soil suspensions by the carrier free and carrier methods and using chemical extractants DTPA-CaCl 2 -NaOAc and EDTA-NH 4 OAc were compared. The 'L' values were significantly correlated with zinc uptake by maize and also with zinc extracted by a number of chemical extractants. The laboratory determinations 'E' values by isotopic exchange equilibria in soil suspension both with and without carrier zinc led to over estimates and gave grossly exggerated values of 'labile zinc' especially in alkaline and high zinc 'fixing' soils. The 'E' values determined in both DTPA-CaCl 2 -NaOAc and EDTA-NH 4 OAc correlated significantly with zinc uptake by maize. These values agreed well with 'L' values and 'available' zinc determined by chemical soil tests. (author)

  3. Isotope study in geothermal fields in Java Island

    International Nuclear Information System (INIS)

    Wandowo, Z.A.

    1995-01-01

    Study in two geothermal fields, Dieng and Kamojang, in Java island by utilizing isotope technique has been carried out. Isotopic data of wells, springs and other geothermal manifestations providing informations on the recharge area of precipitation contributed to geothermal resources, flow paths and origin of geothermal fluids. The data of oxygen shift has also provided information on the characteristic the fields. (author). 8 refs, 5 figs, 3 tabs

  4. A Portable, Field-Deployable Analyzer for Isotopic Water Measurements

    Science.gov (United States)

    Berman, E. S.; Gupta, M.; Huang, Y. W.; Lacelle, D.; McKay, C. P.; Fortson, S.

    2015-12-01

    Water stable isotopes have for many years been used to study the hydrological cycle, catchment hydrology, and polar climate among other applications. Typically, discrete water samples are collected and transported to a laboratory for isotope analysis. Due to the expense and labor associated with such sampling, isotope studies have generally been limited in scope and time-resolution. Field sampling of water isotopes has been shown in recent years to provide dense data sets with the increased time resolution illuminating substantially greater short term variability than is generally observed during discrete sampling. A truly portable instrument also opens the possibility to utilize the instrument as a tool for identifying which water samples would be particularly interesting for further laboratory investigation. To make possible such field measurements of liquid water isotopes, Los Gatos Research has developed a miniaturized, field-deployable liquid water isotope analyzer. The prototype miniature liquid water isotope analyzer (mini-LWIA) uses LGR's patented Off-Axis ICOS (Integrated Cavity Output Spectroscopy) technology in a rugged, Pelican case housing for easy transport and field operations. The analyzer simultaneously measures both δ2H and δ18O from liquid water, with both manual and automatic water introduction options. The laboratory precision for δ2H is 0.6 ‰, and for δ18O is 0.3 ‰. The mini-LWIA was deployed in the high Arctic during the summer of 2015 at Inuvik in the Canadian Northwest Territories. Samples were collected from Sachs Harbor, on the southwest coast of Banks Island, including buried basal ice from the Lurentide Ice Sheet, some ice wedges, and other types of ground ice. Methodology and water analysis results from this extreme field deployment will be presented.

  5. Dosage of plutonium by isotopic dilution in irradiated fuels; Dosage du plutonium par dilution isotopique dans les combustibles irradies

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Plutonium determination in irradiated fuels has been carried out for several years by isotopic dilution by Sebaci and SSM in collaboration. SECACI has made available to the SSM the necessary space and equipment in its Fontenay laboratories. This work has shown the importance of the valency cycle which should make it possible to obtain a uniform isotopic distribution in sample tracer mixtures, and also a satisfactory U/Pu separation. Now it has been noticed that the presence of an excess of uranium considerably modifies the oxidation-reduction reaction kinetics of the plutonium. We have therefore been led to change certain parts of the operational technique so as to have an efficient cycle and to thereby improve the U/Pu separation; the stability of the thermionic emission of the plutonium, connected to the quantity of residual uranium, has at the same time been improved and we can now carry out more precise isotopic analyses. We have also tried to eliminate as far as possible the isotopic contaminations by:using a more rational operational method; the equipment used has been the object of a special study. The evaporations are carried out so as to prevent the formation of saturated vapours inside the glove box. The material which cannot be changed after each operation is carefully cleaned every time a new sample is treated. With this technique, a second calibration of the tracer T{sub 2} has been undertaken using a new standard solution. This solution has been prepared very carefully by weighing uranium and plutonium of known chemical purity, and we believe that it can be guaranteed to be a good reference solution. The value of the {sup 233}U/{sup 242}Pu ratio of the tracer has been obtained with a relative accuracy of 0,5 per cent. This modified method is now being applied to the analysis of rods irradiated in G-3. (author) [French] La determination du plutonium par dilution isotopique dans les combustibles irradies est pratiquee depuis plusieurs annees en

  6. Ghost sector of vacuum string field theory and the projection equation

    International Nuclear Information System (INIS)

    Potting, Robertus; Raeymaekers, Joris

    2002-01-01

    We study the ghost sector of vacuum string field theory where the BRST operator Q is given by the midpoint insertion proposed by Gaiotto, Rastelli, Sen and Zwiebach. We introduce a convenient basis of half-string modes in terms of which Q takes a particularly simple form. We show that there exists a field redefinition which reduces the ghost sector field equation to a pure projection equation for string fields satisfying the constraint that the ghost number is equally divided over the left- and right halves of the string. When this constraint is imposed, vacuum string field theory can be reformulated as a U(∞) cubic matrix model. Ghost sector solutions can be constructed from projection operators on half-string Hilbert space just as in the matter sector. We construct the ghost sector equivalent of various well-known matter sector projectors such as the sliver, butterfly and nothing states. (author)

  7. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  8. Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.

    Science.gov (United States)

    Di Donna, Leonardo; Taverna, Domenico; Indelicato, Serena; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio

    2017-08-15

    A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  10. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 2

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Volume II of the report on the IDA-72 experiment contains papers written by different authors on a number of special topics connected with the preparation, performance and evaluation of the interlaboratory test. In detail the sampling procedures for active samples of the reprocessing plant and the preparation of inactive reference and spike solution from standard material are described as well as new methods of sample conditioning by evaporation. An extra chapter is devoted to the chemical sample treatment as a preparation for mass spectrometric analysis of the U and Pu content of the solutions. Special topics are also methods for mass discrimination corrections, α-spectrometer measurements as a supplement for the determination of Pu-238 and the comparison of concentration determinations by mass spectrometric isotope dilution analysis with those performed by X-ray fluorescence spectrometry. The last part of this volume contains papers connected with the computerized statistical evaluation of the high number of data. (orig.) [de

  11. Automated gravimetric sample pretreatment using an industrial robot for the high-precision determination of plutonium by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Surugaya, Naoki; Hiyama, Toshiaki; Watahiki, Masaru

    2008-01-01

    A robotized sample-preparation method for the determination of Pu, which is recovered by extraction reprocessing of spent nuclear fuel, by isotope dilution mass spectrometry (IDMS) is described. The automated system uses a six-axis industrial robot, whose motility is very fast, accurate, and flexible, installed in a glove box. The automation of the weighing and dilution steps enables operator-unattended sample pretreatment for the high-precision analysis of Pu in aqueous solutions. Using the developed system, the Pu concentration in a HNO 3 medium was successfully determined using a set of subsequent mass spectrometric measurements. The relative uncertainty in determining the Pu concentration by IDMS using this system was estimated to be less than 0.1% (k=2), which is equal to that expected of a talented analysis. The operation time required was the same as that for a skilled operator. (author)

  12. Nuclear orientation experiments concerning odd-A gold isotopes

    International Nuclear Information System (INIS)

    Ligthart, H.J.

    1982-01-01

    This thesis describes nuclear spectroscopy aspects of nuclear orientation in the odd-A gold isotopes 191 Au, 193 Au, 195 Au and 197 Au. These isotopes lie in a transitional region between the spherical nuclei in the lead region and the strongly deformed rare earth isotopes. Following a general introduction to nuclear orientation, the experimental arrangement is described. A new technique is presented that applies in-beam recoil implantation inside the refrigerator itself and this was applied to the case of 191 Au. The three other gold isotopes were oriented using a conventional dilution refrigerator. The nuclear orientation experiments concerning 11/2 - isomers of the isotopes are described. The long-lived isomeric states were oriented using the large hyperfine field of gold in iron. Higher lying levels were studied by nuclear orientation of the Hg parent states. (Auth./C.F.)

  13. Determination of biomass of mango (Mangifera indica L.) trees by non-destructive method using principle of isotope dilution

    International Nuclear Information System (INIS)

    Kotur, S.C.; Keshava Murthy, S.V.

    2003-01-01

    Biomass of 4-year old trees alphonso mango was estimated by injecting of carrier-free 32 P into the trunk followed by radio-assay of the isotope after a complete dilution of 32 P in the tree, being 3 months after injection. The isotopically calculated plant volume (59 903-68 981 cc plant -1 ) and biomass (31.70 - 36.23 kg plant -1 ) showed good agreement but generally overestimated both by about 23% compared to the actual values determined physically (43 720-60 693 cc plant -1 and 22.88-34.78 kg plant -1 , respectively). Application of the technique in a set of another four 15-year old mango trees yielded volume estimates of 1, 70, 749-1 75 835 cc plant -1 (mean=1, 75 835±1.12%) and biomass estimates of 73.0 - 87.4 kg plant -1 (mean=80.45±6.8%). The technique is of promise in fertilizer use efficiency and nutrient dynamics studies in tree crops. (author)

  14. High-precision 27Al/24Mg ratio determination using a modified isotope-dilution approach

    DEFF Research Database (Denmark)

    Paton, Chad; Schiller, Martin; Ulfbeck, David Garf

    2012-01-01

    saves time and minimises the risk of contamination of other samples with spike (which is added immediately prior to analysis). Repeat measurements of the BHVO-2, BCR-2, and BIR-1 international rock standards, as well as a gravimetrically prepared Al–Mg reference solution, indicate that our method......The precision of the 26Al–26Mg system—one of the most widely used chronometers for constraining the relative timing of events in the early solar system—is presently limited by methods for the determination of 27Al/24Mg ratios, which have seen little improvement in the last decade. We present...... a novel method for the measurement of 27Al/24Mg ratios in unpurified sample solutions by multiple-collector inductively coupled plasma mass spectrometry. Because Al is monoisotopic we use a modified isotope dilution approach that employs a mixed spike containing isotopically enriched 25Mg and natural 27Al...

  15. [Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry].

    Science.gov (United States)

    Qiu, Zhongli; Lin, Ying; Xiong, Zhili; Xie, Jianwei

    2014-07-01

    A method for the determination of endogenous agmatine in rat plasma was developed by isotope dilution-gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS). The plasma samples were analyzed after protein precipitation, evaporation, derivatization by hexafluoroacetone (HFAA), and clean-up on a Florisil SPE column. The GC-MS analysis utilized stable isotope d8-agmatine as internal standard. The samples after treatme were tested by negative chemical ionization with selected ion monitoring (SIM) which was set at m/z 492 (molecular ion of agmatine) and m/z 500 (molecular ion of internal standard). The limit of detection (LOD) of agmatine standard solution was 0.005 7 ng/mL. The calibration curve of the agmatine spiked in rat plasma showed a good linear relationship at the range of 1.14-57.0 ng/mL (r = 0.997). The recoveries of agmatine spiked in rat plasma ranged from 92.3% to 109.8%. Inter-day and intra-day precisions were less than 15%. The average concentration level of agmatine in rat plasma was (22 +/- 9) ng/mL, and there was no significant difference between male and female SD rats (p > 0.05). The method is high sensitive and specific, and can be used for the determination of endogenous agmatine in plasma. It provides a strong support for the subsequent research of agmatine.

  16. On the nitrogen isotope dilution analysis by means of the automated NA-5A type 15N-analyzer

    International Nuclear Information System (INIS)

    Faust, H.; Mueller, G.; Stoerl, H.J.

    1976-01-01

    The analytical conditions are investigated under which quantitative nitrogen determination through isotope dilution analysis is possible using the NA-5A type 15 N-analyzer. Calculation of the nitrogen quantity, estimation of the maximum error and the evaluation technique are considered in detail. Test analyses performed on ammonia, urea, and amino acid nitrogen model solutions labelled in different ways yielded good correspondence with preset values. This technique was applied to determine the nitrogen content of biomedical materials. A working scheme for direct quantitative determination of ammonia-N, urea-N, and total-N in urine is presented. (author)

  17. Uranium isotope ratio measurements in field settings

    International Nuclear Information System (INIS)

    Shaw, R.W.; Barshick, C.M.; Young, J.P.; Ramsey, J.M.

    1997-01-01

    The authors have developed a technique for uranium isotope ratio measurements of powder samples in field settings. Such a method will be invaluable for environmental studies, radioactive waste operations, and decommissioning and decontamination operations. Immediate field data can help guide an ongoing sampling campaign. The measurement encompasses glow discharge sputtering from pressed sample hollow cathodes, high resolution laser spectroscopy using conveniently tunable diode lasers, and optogalvanic detection. At 10% 235 U enrichment and above, the measurement precision for 235 U/( 235 U+ 238 U) isotope ratios was ±3%; it declined to ±15% for 0.3% (i.e., depleted) samples. A prototype instrument was constructed and is described

  18. Determination of total cyanide in soil by isotope dilution GC/MS following pentafluorobenzyl derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Campanella, Beatrice, E-mail: beatrice.campanella@pi.iccom.cnr.it [Università di Pisa, Dipartimento di Chimica e Chimica Industriale, via Moruzzi 13, 56124 Pisa (Italy); Consiglio Nazionale delle Ricerche (CNR), Istituto di Chimica dei Composti Organometallici, UOS di Pisa, via Moruzzi 1, 56124 Pisa (Italy); Biancalana, Lorenzo [Università di Pisa, Dipartimento di Chimica e Chimica Industriale, via Moruzzi 13, 56124 Pisa (Italy); D' Ulivo, Lucia [National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6 (Canada); Onor, Massimo; Bramanti, Emilia [Consiglio Nazionale delle Ricerche (CNR), Istituto di Chimica dei Composti Organometallici, UOS di Pisa, via Moruzzi 1, 56124 Pisa (Italy); Mester, Zoltan; Pagliano, Enea [National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6 (Canada)

    2017-04-08

    The high toxicity of cyanide, along with its widespread industrial use, has fuelled interest in the development of analytical methods for its determination in complex matrices. In this study, we propose a novel approach for the measurement of total cyanide in soil samples based on single-step derivatization with pentafluorobenzyl bromide (F{sub 5}Bn−Br) followed by quantitation with gas chromatography mass spectrometry in negative chemical ionization mode. The reaction between CN{sup −} and F{sub 5}Bn−Br resulted in the identification of several derivatives such as F{sub 5}Bn−CN, (F{sub 5}Bn)(F{sub 5}Ph)CH−CN, and (F{sub 5}Bn){sub 2}(F{sub 5}Ph)C−CN. The relative proportion between such compounds was dependent on experimental conditions. When a 100 μL aliquot of an alkaline-aqueous extract was reacted with 700 μL of 1.3% F{sub 5}Bn−Br in acetone, the tri-alkylated derivative was the most abundant. In such conditions a detection limit of 0.5 ng/g of CN{sup −} was attained. Soil samples were initially spiked with an alkaline solution of K{sup 13}C{sup 15}N internal standard and suspended in 7.5% aqueous NaOH. Determination of total cyanide was achieved by digestion of the alkaline extract with H{sub 3}PO{sub 4} to produce HCN which was then trapped in 0.1% NaOH in a sealed double vial system, followed by reaction with F{sub 5}Bn−Br. Isotope dilution calibration was chosen for quantitation, and the validity of the novel method was demonstrated by analysis of soil Certified Reference Materials (CRMs) and by spike recovery tests. - Highlights: • A cost-effective, fast and simple method for determination of total cyanide in soil is presented. • A new micro-distillation strategy was developed overcoming the problems of a conventional distillation. • Negative chemical ionization-mass spectrometer has been exploited to obtain a high sensitivity and specificity. • High accuracy was attained for the analysis of certified reference materials with

  19. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    Science.gov (United States)

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Burn-up determination of irradiated thoria samples by isotope dilution-thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.; Telmore, V.M.; Shah, R.V.; Sant, V.L.; Sasibhushan, K.; Parab, A.R.; Alamelu, D.

    2010-03-01

    Burn-up was determined experimentally using thermal ionization mass spectrometry for two samples from ThO 2 bundles irradiated in KAPS-2. This involved quantitative dissolution of the irradiated fuel samples followed by separation and determination of Th, U and a stable fission product burn-up monitor in the dissolved fuel solution. Stable fission product 148 Nd was used as a burn-up monitor for determining the number of fissions. Isotope Dilution-Thermal Ionisation Mass Spectrometry (ID-TIMS) using natural U, 229 Th and enriched 142 Nd as spikes was employed for the determination of U, Th and Nd, respectively. Atom % fission values of 1.25 ± 0.03 were obtained for both the samples. 232 U content in 233 U determined by alpha spectrometry was about 500 ppm and this was higher by a factor of 5 compared to the theoretically predicted value by ORIGEN-2 code. (author)

  1. Isotope dilution and sampling factors of the quality assurance and TQM of environmental analysis

    International Nuclear Information System (INIS)

    Macasek, F.

    1999-01-01

    Sampling and preparatory treatment of environmental objects is discussed from the view of their information content, functional speciation of the pollutant, statistical distribution treatment and uncertainty assessment. During homogenization of large samples, a substantial information may be lost and validity of environmental information becomes vague. Isotope dilution analysis is discussed as the most valuable tool for both validity of analysis and evaluation of samples variance. Data collection for a non-parametric statistical treatment of series of 'non-representative' sub-samples, and physico-chemical speciation of analyte may actually better fulfill criteria of similarity and representativeness. Large samples are often required due to detection limits of analysis, but the representativeness of environmental samples should by understood not only by the mean analyte concentration, but also by its spatial and time variance. Hence, heuristic analytical scenarios and interpretation of results must be designed by cooperation of environmentalists and analytical chemists. (author)

  2. Deep brine recognition upstream the EBE syndicate. Geochemical and isotopic investigations. Final report

    International Nuclear Information System (INIS)

    2009-01-01

    The authors report and discuss the results obtained after performing a drilling upstream the drinkable water harnessing field of a water supply syndicate in Alsace (Ensisheim, Bollwiller and surroundings), in order to confirm the existence of a deep brine source. This brine is diluted by recent waters. The first isotopic investigations do not allow the origin of this brine to be identified, but fractures due to some seismic events are suspected. The report presents the drilling and the various aspects of the chemical and isotopic studies (sampling, physico-chemical analysis, dating, identification of various isotopes)

  3. Direct measurement of burn up monitor by Pulsed Laser Deposition (PLD) followed by Isotopic Dilution Mass Spectrometry

    International Nuclear Information System (INIS)

    Sajimol, R.; Manoravi, P.; NaIini, S.; Balasubramanian, R.; Joseph, M.

    2012-01-01

    Burn-up measurement is an important aspect in the assessment of fuel performance especially for experimental nuclear fuels. Conventional mass spectrometric technique offer the best accuracy for determination of burn-up but they suffer from the labour intensive and time consuming chemical separation procedures followed by mass spectrometric analysis. Our laboratory has reported a potential laser mass spectrometric technique with advantages of (i) direct and fast measurement of ion intensities of selected rare earth element and residual heavy element atoms to deduce burn up and (ii) adaptability to remote handling of radioactive samples. Direct quantification of burn up monitor element in fuel in the form of pellet as well as liquid was probed by pulsed laser deposition followed by Isotopic Dilution Mass Spectrometric technique (IDMS). The procedure involving laser ablation of heavy element (namely U and Pu) and fission product (Nd, La etc) from a simulated spent fuel matrix followed by isotopic dilution mass spectrometry using thermal ionization mass spectrometry (TIMS) has been presently attempted to arrive at the rare earth element to heavy element ratio to deduce burn up using the methodology described in our earlier work. The details of IDMS technique has been reviewed by Heumann et al. Accurately weighed amounts of major rare earth fission products such as Nd, La, Ce and Sm in solution form were mixed with known quantity of uranium solution (all the weights are corresponding to their fission yields and the residual heavy element atoms after a given burn up) and mixed together to attain uniformity. The solution is then dried and resulting powder was pelletized and sintered. Subsequently, the pellet was ablated with pulsed laser (8 ns, 532 nm, Nd-YAG) and the plume was deposited on a glass plate. This deposit was dissolved in minimum amount of nitric acid. A known volume of the solution was mixed with spike (for e.g., 150 Nd/ 142 Nd, 233 U/ 238 U in this study

  4. Field measurement program to determine far field plume dilution parameters

    International Nuclear Information System (INIS)

    Orth, R.C.; Carter, H.H.; Miyasaki, M.T.

    1974-01-01

    A description of the techniques used to obtain measurements of temperature, salinity, tidal velocity and tracer concentration required to determine the far field dilution in a shallow estuary is presented. The study was done to characterize the physical hydrography of the Bush River, a tributary estuary of the Chesapeake Bay, which is a possible recipient of the thermal discharge from a proposed power plant consisting of two 850 MWe nuclear generating units. Measurements of temperature and salinity along the axis of the estuary during periods of high and low fresh water inflow were obtained for use in the development of a one-dimensional-segmented transient state model of the estuary. Computer concentrations from the model compared favorably with measured dye concentrations for the same periods of high and low freshwater inflow

  5. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition

    DEFF Research Database (Denmark)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita

    2017-01-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body...... composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work...... quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques....

  6. Analyses of turbulent flow fields and aerosol dynamics of diesel engine exhaust inside two dilution sampling tunnels using the CTAG model.

    Science.gov (United States)

    Wang, Yan Jason; Yang, Bo; Lipsky, Eric M; Robinson, Allen L; Zhang, K Max

    2013-01-15

    Experimental results from laboratory emission testing have indicated that particulate emission measurements are sensitive to the dilution process of exhaust using fabricated dilution systems. In this paper, we first categorize the dilution parameters into two groups: (1) aerodynamics (e.g., mixing types, mixing enhancers, dilution ratios, residence time); and (2) mixture properties (e.g., temperature, relative humidity, particle size distributions of both raw exhaust and dilution gas). Then we employ the Comprehensive Turbulent Aerosol Dynamics and Gas Chemistry (CTAG) model to investigate the effects of those parameters on a set of particulate emission measurements comparing two dilution tunnels, i.e., a T-mixing lab dilution tunnel and a portable field dilution tunnel with a type of coaxial mixing. The turbulent flow fields and aerosol dynamics of particles are simulated inside two dilution tunnels. Particle size distributions under various dilution conditions predicted by CTAG are evaluated against the experimental data. It is found that in the area adjacent to the injection of exhaust, turbulence plays a crucial role in mixing the exhaust with the dilution air, and the strength of nucleation dominates the level of particle number concentrations. Further downstream, nucleation terminates and the growth of particles by condensation and coagulation continues. Sensitivity studies reveal that a potential unifying parameter for aerodynamics, i.e., the dilution rate of exhaust, plays an important role in new particle formation. The T-mixing lab tunnel tends to favor the nucleation due to a larger dilution rate of the exhaust than the coaxial mixing field tunnel. Our study indicates that numerical simulation tools can be potentially utilized to develop strategies to reduce the uncertainties associated with dilution samplings of emission sources.

  7. Simultaneous quantification of endogenous and exogenous plasma glucose by isotope dilution LC-MS/MS with indirect MRM of the derivative tag.

    Science.gov (United States)

    Yu, Lingling; Wen, Chao; Li, Xing; Fang, Shiqi; Yang, Lichuan; Wang, Tony; Hu, Kaifeng

    2018-03-01

    Quantification of endogenous and exogenous plasma glucose can help more comprehensively evaluate the glucose metabolic status. A ratio-based approach using isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) with indirect multiple reaction monitoring (MRM) of the derivative tag was developed to simultaneously quantify endo-/exogenous plasma glucose. Using diluted D-[ 13 C 6 ] glucose as tracer of exogenous glucose, 12 C 6 / 13 C 6 glucoses were first derivatized and then data were acquired in MRM mode. The metabolism of exogenous glucose can be tracked and the concentration ratio of endo/exo-genous glucose can be measured by calculating the endo-/exo-genous glucose concentrations from peak area ratio of specific daughter ions. Joint application of selective derivatization and MRM analysis not only improves the sensitivity but also minimizes the interference from the background of plasma, which warrants the accuracy and reproducibility. Good agreement between the theoretical and calculated concentration ratios was obtained with a linear correlation coefficient (R) of 0.9969 in the range of D-glucose from 0.5 to 20.0 mM, which covers the healthy and diabetic physiological scenarios. Satisfactory reproducibility was obtained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 5.16%, and relative recoveries of 85.96 to 95.92% were obtained at low, medium, and high concentration, respectively. The method was successfully applied to simultaneous determination of the endo-/exogenous glucose concentration in plasma of non-diabetic and type II diabetic cynomolgus monkeys. Graphical Abstract The scheme of the proposed ratio-based approach using isotope dilution LC-MS/MS with indirect MRM of the derivative tag for simultaneous quantification of endogenous and exogenous plasma glucose.

  8. Tricritical behavior in the diluted transverse spin-1 Ising model with a longitudinal crystal field

    International Nuclear Information System (INIS)

    Htoutou, K.; Oubelkacem, A.; Ainane, A.; Saber, M.

    2005-01-01

    The transverse spin-1 Ising model with a longitudinal crystal field exhibits a tricritical behavior. Within the effective field theory with a probability distribution technique that accounts for the self-spin correlations, we have studied the influence of site dilution on this behavior and have calculated the temperature-transverse field-longitudinal crystal field-concentration phase diagrams and determined, in particular, the influence of the concentration of magnetic atoms c on the tricritical behavior. We have found that the tricritical point appears for large values of the concentration c of magnetic atoms and disappears with the increase in dilution (small values of c). Results for square lattice are calculated numerically and some interesting results are obtained. In certain ranges of values of the strength of the longitudinal crystal field D/J when it becomes sufficiently negative, we found re-entrant phenomenon, which disappears with increase in the value of the strength of the transverse field

  9. Study of ferrallitisation process in soil by application of isotopic dilution kinetic technique to iron

    International Nuclear Information System (INIS)

    Thomann, Christiane

    1978-01-01

    Isotopic dilution kinetic technique applied to iron may contribute to make clear the conditions of ''potential'' mobility of iron in soils, under the action of three factors: moisture, incubation period and organic matter imputs. Comparison between surface horizons of three tropical soils: leached ferruginous tropical soil, weakly ferrallitic red soil and ferrallitic soil shows that in the ferrallitisation process, weakly ferrallitic soil would take place between the two other types of soils with a maximum mobility of iron. This mobility decreases when organic matter rate decreases leading then to ''beige'' soil (ferruginous leached tropical soil), and when hydroxide rate increases, which leads to ferrallitic soil. In podzol (A 1 horizon), for the same rate of organic matter, potential mobility of iron is higher than in ferallitic soil, because it contains ten times more free iron than the podzol [fr

  10. Certification measurement of the cadmium, copper and lead contents in rice using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Vassileva, Emilia; Quetel, Christophe R.

    2004-01-01

    This paper describes the certification of the Cd, Cu and Pb amount contents in a rice material, that were used as reference values for round 19 of the international measurement evaluation programme (IMEP). The protocol developed in this study was based on isotope dilution associated to inductively coupled plasma mass spectrometry (ID-ICP-MS). A multiple spiking approach was applied to reduce significantly the number of analytical steps. For the decomposition of the sample, three different microwave assisted digestion procedures were tested and compared. The use of hydrofluoric acid was found necessary to ensure full solubilisation and complete isotopic equilibration. Estimation of the combined uncertainty attached to the measurement results was performed according to the ISO guidelines. Contributions from the correction for moisture content, sample homogeneity, procedural blank, spike impurities, spectral interferences, instrumental background and dead-time effects were evaluated. SI-traceable values with less than 2% combined uncertainty (k = 2) were obtained for Cd, Cu and Pb, respectively, (14.39 ± 0.21) x 10 -6 mol kg -1 , (44.31 ± 0.42) x 10 -6 mol kg -1 and (2.034 ± 0.034) x 10 -6 mol kg -1 . The rice powder was observed to be highly hygroscopic and a second series of isotope dilution mass spectrometry measurements was carried out on samples in equilibrium with the ambient moisture conditions ('saturated' samples). The Comite Consultatif pour la Quantite de Matiere (CCQM) requested this approach for the participation to the key comparison 24 on the same rice test material. The excellent agreement for Cd between the IMEP-19 reference value, the value submitted by the institute for reference materials and measurements (IRMM) to CCQM-K24 and the corresponding reference value obtained as the arithmetic mean from the results of the 11 participating National Measurement Institutes (less than 0.27% difference) further validated this work. Eventually, this series

  11. Quantification of urea in serum by isotope dilution HPLC/MS

    International Nuclear Information System (INIS)

    Lee, Hwa Shim; Park, Sang Ryoul

    2005-01-01

    Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is the end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed Isotope Dilution-Liquid Chromatography/Mass Spectrometry (ID-LC/MS) as a candidate primary method, in which 15 N 2 -urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provide low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an ElectroSpry Ionization(ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum Certified Reference Materials (CRMs)

  12. Quantitation of DNA adducts by stable isotope dilution mass spectrometry

    Science.gov (United States)

    Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory

    2012-01-01

    Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593

  13. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  14. In vivo synthesized 34S enriched amino acid standards for species specific isotope dilution of proteins

    DEFF Research Database (Denmark)

    Hermann, Gerrit; Moller, Laura Hyrup; Gammelgaard, Bente

    2016-01-01

    (ICP-MS) combined to anion exchange showed that very high concentrated spike material could be produced with [small mu ]mol amounts of proteinogenic sulfur containing amino acids per g cell dry weight. An enrichment of 34S to 96.3 +/- 0.4% (n = 3) and 98.5 +/- 0.4% (n = 3) for cysteic acid...... with the concept of species specific isotope dilution analysis (IDA). The method relies on the determination of the two sulfur containing amino acids, cysteine and methionine by sulfur speciation analysis and is hence applicable to any protein containing sulfur. In vivo synthesis using 34S as sulfur source...... and methionine sulfone, respectively, was assessed. The established IDA method was validated for the absolute quantification of commercially available lysozyme and ceruloplasmin standards including the calculation of a total combined uncertainty budget....

  15. Application of 1- (3,4-dimenthylphenyl)-dodecanedione-1,2-dioxime (MFDDO) to substoichiometris extraction and determination of nickel(II) by the isotope dilution method

    Energy Technology Data Exchange (ETDEWEB)

    Gorski, Z.; Goraczko, W. [Technical University Poznan, Poznan (Poland). Radio and Photo Chemistry Department

    1997-10-01

    The conditions for use of 1-3,4-dimenthylphenyl-dodecanedione-1,2-dioxime (MFDDO) in toluene solution for substoichiometric extraction of Ni(II) from aqueous phases are described. This procedure allows the determination of 0.006-0.06 g/ml of nickel(II) in human urine and blood`s serum samples by the isotope dilution method using {sup 63}Ni(II) 9 refs., 5 figs.

  16. Superstring field theory equivalence: Ramond sector

    International Nuclear Information System (INIS)

    Kroyter, Michael

    2009-01-01

    We prove that the finite gauge transformation of the Ramond sector of the modified cubic superstring field theory is ill-defined due to collisions of picture changing operators. Despite this problem we study to what extent could a bijective classical correspondence between this theory and the (presumably consistent) non-polynomial theory exist. We find that the classical equivalence between these two theories can almost be extended to the Ramond sector: We construct mappings between the string fields (NS and Ramond, including Chan-Paton factors and the various GSO sectors) of the two theories that send solutions to solutions in a way that respects the linearized gauge symmetries in both sides and keeps the action of the solutions invariant. The perturbative spectrum around equivalent solutions is also isomorphic. The problem with the cubic theory implies that the correspondence of the linearized gauge symmetries cannot be extended to a correspondence of the finite gauge symmetries. Hence, our equivalence is only formal, since it relates a consistent theory to an inconsistent one. Nonetheless, we believe that the fact that the equivalence formally works suggests that a consistent modification of the cubic theory exists. We construct a theory that can be considered as a first step towards a consistent RNS cubic theory.

  17. Soil organic matter (SOM) dynamics determined by stable isotope techniques

    International Nuclear Information System (INIS)

    Gerzabek, M. H.

    1998-09-01

    Being aware of limitations and possible bias the 13 C natural abundance technique using the different 13 C enrichments in plants with differing photosynthetic pathways in a powerful tool to quantify turnover processes, both in long-term field studies and short-term laboratory experiments. Special care is needed in choosing reference plots and the proper number of replicate samples. The combination of 13 C and 14 C measurements has a high potential for a further improvement of isotope techniques in SOM studies. Natural abundance of 15 N is less powerful with respect to quantification of SOM processes than the isotope dilution technique. However its usefulness could be distinctly improved by introducing other stable isotopes into the studies.(author)

  18. Multi-element determination in environmental samples by mass spectrometric isotope dilution analysis using thermal ionization. Pt. 2

    International Nuclear Information System (INIS)

    Hilpert, K.; Waidmann, E.

    1988-01-01

    An analytical procedure for the multi-element analysis of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Ba, Tl, and Pb in pine needles by mass spectrometric isotope dilution analysis using thermal ionization has been reported in Part I of this paper. This procedure is now transferred to the non-vegetable material 'Oyster Tissue' (Standard Reference Material 1566, National Bureau of Standards, USA). By a modification of the analytical procedure, it was possible to determine Cr in this material in addition to the aforementioned elements. No concentrations are certified for the elements Ga, Ba and Tl analyzed in this work. The concentrations of the remaining elements obtained by the multi-element analysis agree well with those certified. (orig.)

  19. Development of multi-residue method for the determination of pesticides in cereal matrices by isotopic dilution associated to liquid chromatography coupled to tandem mass spectrometry after pressurized liquid extraction

    International Nuclear Information System (INIS)

    El Mrabet, Khadija

    2008-01-01

    Pesticides are nowadays considered as toxic for human health. The maximal residues levels authorized in water and foodstuff are more and more strict. Therefore, selective analytical techniques are necessary for their identification and their quantification. The aim of this thesis was to develop a multi-residue method for the determination of pesticides by isotopic dilution associated to liquid chromatography (LC) coupled with tandem mass spectrometry (MS"2) after pressurized liquid extraction. In a first step, an analysis method of phenyl-ureas and triazines in groundwater by isotopic dilution associated to LC/MS"2 after solid phase extraction has been developed. The method has been validated and evaluated by participating to an inter-laboratory study. Concerning cereals, an extraction method of pesticides associated to an analysis by LC/MS"2 has been developed for thirty-eight pesticides representative of twenty-six chemicals families and fourteen labeled compounds in wheat. The analysis has been carried out in reversed phase chromatography. Separation and detection conditions have been optimized. A global analytical protocol consisting of a pressurized liquid extraction step using acetonitrile at 100 deg. C and at 100 bars and followed by purification step of the resulting extract on a polymeric sorbent was developed. The developed method enables to extract thirty-eight pesticides and fourteen labeled compounds from wheat with recovery yield about 85% (RSD =4%, n=3). Moreover, the results show that the application of isotopic dilution can be complex. Although some improvements need to be added regarding experimentation of aged matrices or contaminated samples, the potential of the method has been demonstrated. (author) [fr

  20. Integrated modelling of enhanced in situ biodenitrification in a fractured aquifer: biogeochemistry and isotope geochemistry

    Science.gov (United States)

    Rodríguez-Escales, Paula; Folch, Albert; van Breukelen, Boris M.; Vidal-Gavilan, Georgina; Soler, Albert

    2014-05-01

    Enhanced in-situ biodenitrification is a feasible technology to recovery groundwater polluted by nitrates and achieves drinking water standards. Under optimum conditions, nitrate is reduced by autochthonous bacteria trough different reactions until arrive to harmless dinitrogen gas. Isotopic fractionation monitoring in field applications allows knowing the exact degree and the real scope of this technology. Using the Rayleigh equation the change in the isotope ratio of the nitrate molecule (δ15N-NO3-, δ18O-NO3-) is related to the fraction of molecules remaining as a result of biodenitrification. However, Rayleigh application at field scale is sometimes limited due to other processes involved during groundwater flow such as dispersion or adsorption and geological media heterogeneities that interferes in concentration values. Then, include isotope fractionation processes in reactive transport models is a useful tool to interpret and predict data from in-situ biodenitrification. We developed a reactive transport model of enhanced in situ application at field scale in a fractured aquifer that considers biogeochemical processes as well as isotope fractionation to enable better monitoring and management of this technology. Processes considered were: microbiological- exogenous and endogenous nitrate and sulfate respiration coupled with microbial growth and decay, geochemical reactions (precipitation of calcite) and isotopic fractionation (δ15N-NO3-; δ18O- NO3- and carbon isotope network). The 2-D simulations at field scale were developed using PHAST code. Modeling of nitrate isotope geochemistry has allowed determining the extent of biodenitrification in model domain. We have quantified which is the importance in decreasing of nitrate concentrations due to biodegradation (percentage of biodegradation, 'B%') and due to dilution process (percentage of dilution, 'D%'). On the other hand, the stable carbon isotope geochemistry has been modeled. We have considered the

  1. Method development for the determination of cadmium, copper, lead, selenium and thallium in sediments by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry and isotopic dilution calibration

    International Nuclear Information System (INIS)

    Dias, Lucia Felicidade; Miranda, Gilson R.; Saint'Pierre, Tatiana D.; Maia, Sandra M.; Frescura, Vera L.A.; Curtius, Adilson J.

    2005-01-01

    A procedure for the determination of Cd, Cu, Pb, Se and Tl by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) with calibration by isotopic dilution is proposed. The slurry is prepared by mixing the sample with diluted nitric and hydrofluoric acids in an ultrasonic bath and then in a water bath at 60 deg C for 120 min. The slurries were let to stand at least for 12 h, manually shaken before poured into the autosampler cups and homogenized by passing through an argon flow, just before pipetting it into the furnace. The analytes were determined in two groups, according to their thermal behaviors. The furnace temperature program was optimized and the selected compromised pyrolysis temperatures were: 400 deg C for Cd, Se and Tl and 700 deg C for Cu and Pb. The vaporization temperature was 2300 deg C. The analyses were carried out without modifier as no significant effect was observed for different tested modifiers. Different sample particle sizes did not affect the sensitivity significantly, then a particle size ≤50 μm was adopted. The accuracy was checked by analyzing five certified reference sediments, with analytes concentrations from sub-μg g -1 to a few hundreds μg g -1 . The great majority of the obtained concentrations were in agreement with the certified values. The detection limits, determined for the MESS-2 certified sediment, were, in μg g -1 : 0.01 for Cd; 0.8 for Cu; 0.4 for Pb; 0.4 for Se and 0.06 for Tl. The precision was adequate with relative standard deviations lower than 12%. Isotopic dilution showed to be an efficient calibration technique for slurry, as the extraction of the analyte to the liquid phase of the slurry and the reactions in the vaporizer must help the equilibration between the added isotope and the isotope in the sample

  2. Accuracy of some routine method used in clinical chemistry as judged by isotope dilution-mass spectrometry

    International Nuclear Information System (INIS)

    Bjoerkhem, I.; Bergman, A.; Falk, O.; Kallner, A.; Lantto, O.; Svensson, L.; Akerloef, E.; Blomstrand, R.

    1981-01-01

    Serum from patients was pooled, filtered, dispensed, and frozen. This pooled specimen was used for accuracy control in 64 participating laboratories in Sweden. Mean values (state-of-the-art values) were obtained for creatinine, cholesterol, glucose, urea, uric acid, and cortisol. These values were compared with values obtained with highly accurate reference methods based on isotope dilution-mass spectrometry. Differences were marked in the case of determination of creatinine and cortisol. Concerning the other components, the differences between the state-of-the-art value and the values obtained with the reference methods were negligible. Moreover, the glucose oxidase and the oxime methods for determination of glucose and urea were found to give significantly lower values than the hexokinase and urease methods, respectively. Researchers conclude that methods with a higher degree of accuracy are required for routine determination of creatinine and cortisol

  3. Effects of buffer composition and dilution on nanowire field-effect biosensors

    International Nuclear Information System (INIS)

    Lloret, Noémie; Frederiksen, Rune S; Møller, Thor C; Rieben, Nathalie I; Martinez, Karen L; Upadhyay, Shivendra; Nygård, Jesper; De Vico, Luca; Jensen, Jan H

    2013-01-01

    Nanowire-based field-effect transistors (FETs) can be used as ultra-sensitive and label-free biosensors for detecting protein–protein interactions. A way to increase the performance of such sensors is to dilute the sensing buffer drastically. However, we show here that this can have an important effect on the function of the proteins. Moreover, it is demonstrated that this dilution significantly affects the pH stability of the sensing buffer, which consequently impacts the charge of the protein and thus the response and signal-to-noise ratio in the sensing experiments. Three model systems are investigated experimentally to illustrate the impact on ligand–protein and protein–protein interactions. Simulations are performed to illustrate the effect on the performance of the sensors. Combining various parameters, the current study provides a means for evaluating and selecting the most appropriate buffer composition for bioFET measurements. (paper)

  4. Determination of Cd, Pb, Zn and Cu in Sediment Compartments by Sequential Extraction and Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (ID-ICP-MS

    Directory of Open Access Journals (Sweden)

    Gardolinski Paulo C. F. C.

    2002-01-01

    Full Text Available Trace concentrations of Cd, Cu, Pb and Zn in four different sediment fractions extracted in sequence were determined by isotope dilution inductively coupled mass spectrometry (IDICPMS. The metals from each fraction were extracted following the sequential extraction procedure recommended by the Bureau Commun de Référence (BCR of the Commission of the European Communities. As an alternative to external calibration, the elements were quantified by spiking the extracted solutions with 112Cd, 63Cu, 208Pb and 66Zn and application of isotope dilution. The proposed approach was applied to a sample collected from a lake and two standard reference materials, NIST2704 river sediment from the National Institute of Standards & Technology and the BCR-277 estuarine sediment. Detection limits, for each extracted solution, varied from 0.31 to 0.53 mug L¹ for Cd, 0.92 to 2.9 mug L¹ for Cu, 0.22 to 1.1 mug L¹ for Pb and 1.3 to 7.6 mug L¹ for Zn. The sum of the metals concentration in the different fractions was compatible with 95% confidence level found amounts obtained with complete digestion of the samples and with the certified values of the standard reference materials.

  5. High-frequency field-deployable isotope analyzer for hydrological applications

    Science.gov (United States)

    Elena S.F. Berman; Manish Gupta; Chris Gabrielli; Tina Garland; Jeffrey J. McDonnell

    2009-01-01

    A high-frequency, field-deployable liquid water isotope analyzer was developed. The instrument was deployed for 4 contiguous weeks in the H. J. Andrews Experimental Forest Long-term Ecological Research site in western Oregon, where it was used for real-time measurement of the isotope ratios of precipitation and stream water during three large storm events. We were able...

  6. Isotope dilution measurement of copper absorption and excretion in rats fed different carbohydrates

    International Nuclear Information System (INIS)

    Johnson, P.E.; Bowman, T.D.

    1986-01-01

    An isotope dilution method using 67 Cu was developed to measure true absorption (A) and endogenous excretion (EE) of Cu in rats. Specific activity (SA) of injected 67 Cu was least variable in 7 tissues on days 6-8 after injection. SA of feces compared to tissues was used to calculate EE and A. This method was used to study Cu metabolism in rats fed 5 ppm or 0.4 ppm Cu and diets containing fructose (FR), glucose (GL), sucrose (SU), or cornstarch (CS). In rats fed 5 ppm Cu, the A, EE, and balance (B) were greatest for CS animals. There were no differences in A, B, or EE between FR and SU rats (p > .05). Rats fed GL had B and A lower than other groups (p .05). Liver Cu did not differ among groups fed 0.4 ppm Cu. Kidney Cu was higher ( p .05) compared to rats fed GL and 5 ppm Cu. EE was significantly lower in all groups on 0.4 ppm Cu than 5 ppm Cu. EE was 1 μg Cu/d on the 0.4 ppm Cu diet

  7. The measurement of the chemically mobile fraction of lead in soil using isotopic dilution analysis

    International Nuclear Information System (INIS)

    Kirchhoff, J.; Brand, J.; Schuettelkopf, H.

    1992-12-01

    The chemically available fraction of lead in eight soils measured by isotopic dilution analysis using 212 Pb ranged from 7 to 16% of the total content of lead in soil. The soluble fractions achieved values up to 63% of the total content in 1 M NH 4 NO 3 , 1 M MgCl 2 and 0.05 M DTPA solutions. Increasing the contact time between water and soil, the water-soil ratio from 1:1 to 5:1 and increasing the temperature of the soil-water suspension raised the chemically available fraction in soil. Comparing various soil parameters and the mobile fraction of lead, only pH shows a significant correlation. The amphoteric character of lead causes a minimum of mobility about pH 6; pH-values below are responsible for the higher mobility of lead as Pb 2+ , at pH-values above 6 soluble hydroxy and humic acid complexes are formed. (orig.) [de

  8. Sectoral programming mission isotope techniques for geothermal development. Philippines. UNDP sectoral support

    International Nuclear Information System (INIS)

    Froehlich, K.; Sun, Y.

    1995-10-01

    This report discusses the accomplishments of IAEA Technical Cooperation project PHI/8/016 ''Isotope Techniques in Geothermal Hydrology''. It is intended to help Philippine National Oil Company's Energy Development Corporation (PNOC-EDC) in use of isotope techniques for geothermal development. This report discusses outcomes of the mission, conclusions and recommendations on applications of isotopes techniques in geothermal agro-industrial plants and geothermal hydrology

  9. The isotopic contamination in electromagnetic isotope separators; La contagion isotopique dans les separateurs electromagnetiques d'isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Cassignol, Ch [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In the early years of isotope separation, and in particular electromagnetic isotope separation, needs for rapid results have conducted to empiric research. This paper describes fundamental research on the electromagnetic isotope separation to a better understanding of isotope separators as well as improving the performances. Focus has been made on the study of the principle of isotope contamination and the remedial action on the separator to improve the isotope separation ratio. In a first part, the author come back to the functioning of an electromagnetic separator and generalities on isotope contamination. Secondly, it describes the two stages separation method with two dispersive apparatus, an electromagnetic separation stage followed by an electrostatic separation stage, both separated by a diaphragm. The specifications of the electrostatic stage are given and its different settings and their consequences on isotope separation are investigated. In a third part, mechanisms and contamination factors in the isotope separation are discussed: natural isotope contamination, contamination by rebounding on the collector, contamination because of a low resolution, contamination by chromatism and diffusion effect, breakdown of condenser voltage. Analysis of experimental results shows the diffusion as the most important contamination factor in electromagnetic isotope separation. As contamination factors are dependent on geometric parameters, sector angle, radius of curvature in the magnetic field and clearance height are discussed in a fourth part. The better understanding of the mechanism of the different contamination factors and the study of influential parameters as pressure and geometric parameters lead to define a global scheme of isotope contamination and determinate optima separator design and experimental parameters. Finally, the global scheme of isotope contamination and hypothesis on optima specifications and experimental parameters has been checked during a

  10. Determination of tungsten in high-alloy steels and heat resisting alloys by isotope dilution-spark source mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa; Yamada, Kei; Okochi, Haruno; Hirose, Fumio

    1983-01-01

    Tungsten in high-alloy steels and heat-resisting alloys was determined by isotope dilution method combined with spark source mass spectrometry by using 183 W enriched tungsten. The spike solution was prepared by fusing tungsten trioxide in sodium carbonate. A high-alloy steel sample was dissolved in the mixture of sulfuric acid and phosphoric acid together with the spike solution; a sample of heat resisting alloy was similarly dissolved in the mixture of hydrochloric acid, nitric acid, sulfuric acid, and phosphoric acid. The solution was evaporated to give dense white fumes. Tungsten was separated from the residue by a conventional cinchonine salt-precipitation method. The salt was ignited, and the residue was mixed with graphite powder and pressed into electrodes. The isotope 183 W and 184 W were measured. The method was applied to the determination of tungsten in JSS and NBS standard high-alloy steels and JAERI standard nickel- and NBS standard cobalt-base heat resisting alloys containing more than 0.05% tungsten. The results were obtained with satisfactory precision and accuracy. However, the results obtained for JSS standard high- speed steels containing molybdenum tended to be significantly lower than the certified values. (author)

  11. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    Science.gov (United States)

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Experimental design-based isotope-dilution SPME-GC/MS method development for the analysis of smoke flavouring products.

    Science.gov (United States)

    Giri, Anupam; Zelinkova, Zuzana; Wenzl, Thomas

    2017-12-01

    For the implementation of Regulation (EC) No 2065/2003 related to smoke flavourings used or intended for use in or on foods a method based on solid-phase micro extraction (SPME) GC/MS was developed for the characterisation of liquid smoke products. A statistically based experimental design (DoE) was used for method optimisation. The best general conditions to quantitatively analyse the liquid smoke compounds were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 60°C extraction temperature, 30 min extraction time, 250°C desorption temperature, 180 s desorption time, 15 s agitation time, and 250 rpm agitation speed. Under the optimised conditions, 119 wood pyrolysis products including furan/pyran derivatives, phenols, guaiacol, syringol, benzenediol, and their derivatives, cyclic ketones, and several other heterocyclic compounds were identified. The proposed method was repeatable (RSD% <5) and the calibration functions were linear for all compounds under study. Nine isotopically labelled internal standards were used for improving quantification of analytes by compensating matrix effects that might affect headspace equilibrium and extractability of compounds. The optimised isotope dilution SPME-GC/MS based analytical method proved to be fit for purpose, allowing the rapid identification and quantification of volatile compounds in liquid smoke flavourings.

  13. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Science.gov (United States)

    Banerjee, Ananya; Sarkar, A.

    2016-05-01

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  14. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Ananya, E-mail: banerjee.ananya2008@gmail.com; Sarkar, A. [Dept. of Physics, Bijoy Krishna Girls’ College, 5/3 M.G. Road, Howrah 711101, W.B. (India)

    2016-05-06

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  15. Analysis of ochratoxin A in grapes, musts and wines by LC–MS/MS: First comparison of stable isotope dilution assay and diastereomeric dilution assay methods

    Energy Technology Data Exchange (ETDEWEB)

    Roland, Aurélie, E-mail: aurelie@nyseos.fr [Nyseos, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Bros, Pauline, E-mail: pauline.bros@gmail.com [Institut Français de la Vigne et du Vin, UMT Qualinnov, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Bouisseau, Anaïs, E-mail: anais.bouisseau@gmail.com [Nyseos, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Institut des Biomolécules Max Mousseron, UMR-CNRS-5247, Universités Montpellier I and II, Place Eugène Bataillon, 34095 Montpellier (France); Cavelier, Florine, E-mail: florine@univ-montp2.fr [Institut des Biomolécules Max Mousseron, UMR-CNRS-5247, Universités Montpellier I and II, Place Eugène Bataillon, 34095 Montpellier (France); Schneider, Rémi, E-mail: remi.schneider@vignevin.com [Institut Français de la Vigne et du Vin, UMT Qualinnov, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France)

    2014-03-01

    Highlights: • OTA extraction on immunoaffinity columns is not adapted for DIDA quantification. • The use of a labeled internal standard is compulsory to obtain reliable results. • SIDA and DIDA quantification approaches have been compared for the first time. Abstract: Ochratoxin A (OTA) exhibits potent nephrotoxic, carcinogenic and teratogenic effects and its maximum level in wines has been set to 2 μg L⁻¹ by regulation. Consequently, the analytical procedures for OTA determination in wines have to be both very sensitive and reliable. In this paper, we compared two quantification methods: the stable isotope dilution assay (SIDA) and the diastereomeric dilution assay (DIDA). For this purpose, non-natural analogues of OTA were synthesized: the labeled OTA (OTA-d₄) as a diastereomeric mixture for the SIDA and one non-natural OTA’s diastereomer (OTA-dia) for the DIDA. To quantify OTA in red grapes, musts or wines, the sample preparation was optimized using immunoaffinity column extraction and the analysis was performed by LC–MS/MS in Multiple Reaction Monitoring mode. A validation procedure in agreement with the International Organization of Vine and Wine recommendations was conducted. It appeared that SIDA quantification exhibited excellent sensitivity (LOD < 1 ng L⁻¹), accuracy (recovery = 98%), repeatability (RSD < 3%) and intermediate reproducibility (RSD < 4%) compared to quantification by DIDA. Indeed, DIDA method did not provide satisfactory results demonstrating that immunoaffinity extraction is exclusively selective for the natural OTA and not for its diastereomer, which therefore cannot be considered as a good internal standard for this particular method.

  16. Analysis of ochratoxin A in grapes, musts and wines by LC–MS/MS: First comparison of stable isotope dilution assay and diastereomeric dilution assay methods

    International Nuclear Information System (INIS)

    Roland, Aurélie; Bros, Pauline; Bouisseau, Anaïs; Cavelier, Florine; Schneider, Rémi

    2014-01-01

    Highlights: • OTA extraction on immunoaffinity columns is not adapted for DIDA quantification. • The use of a labeled internal standard is compulsory to obtain reliable results. • SIDA and DIDA quantification approaches have been compared for the first time. - Abstract: Ochratoxin A (OTA) exhibits potent nephrotoxic, carcinogenic and teratogenic effects and its maximum level in wines has been set to 2 μg L −1 by regulation. Consequently, the analytical procedures for OTA determination in wines have to be both very sensitive and reliable. In this paper, we compared two quantification methods: the stable isotope dilution assay (SIDA) and the diastereomeric dilution assay (DIDA). For this purpose, non-natural analogues of OTA were synthesized: the labeled OTA (OTA-d 4 ) as a diastereomeric mixture for the SIDA and one non-natural OTA’s diastereomer (OTA-dia) for the DIDA. To quantify OTA in red grapes, musts or wines, the sample preparation was optimized using immunoaffinity column extraction and the analysis was performed by LC–MS/MS in Multiple Reaction Monitoring mode. A validation procedure in agreement with the International Organization of Vine and Wine recommendations was conducted. It appeared that SIDA quantification exhibited excellent sensitivity (LOD −1 ), accuracy (recovery = 98%), repeatability (RSD < 3%) and intermediate reproducibility (RSD < 4%) compared to quantification by DIDA. Indeed, DIDA method did not provide satisfactory results demonstrating that immunoaffinity extraction is exclusively selective for the natural OTA and not for its diastereomer, which therefore cannot be considered as a good internal standard for this particular method

  17. Sub-stoichiometric isotope dilution analysis method for the determination of iodine in common salts using iodine-131 tracer

    International Nuclear Information System (INIS)

    Singh, Vivek; Garg, A.N.

    1994-01-01

    A sub-stoichiometric isotope dilution analysis (SIDA) method was developed for the determination of iodine in different brands of common salts. An aqueous salt solution containing 131 I tracer and NaI as carrier is oxidized by tartaric acid and KIO 3 and the liberated iodine is extracted with CCl 4 . To the extract an aqueous solution of AgNO 3 is added in substoichiometric amount to obtain a colloidal solution of AgI. On adding sodium thiosulfate solution, the NaI so formed passes into aqueous solution, which is then counted. Several different brands of salt were analysed. The method is especially suitable for the determination of microgram amounts of iodide in the presence of excess of chloride. (Author)

  18. Analysis of trace metals (Cu, Cd, Pb, and Fe) in seawater using single batch nitrilotriacetate resin extraction and isotope dilution inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Mi [Department of Earth, Atmospheric, and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Boyle, Edward A., E-mail: eaboyle@mit.edu [Department of Earth, Atmospheric, and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Echegoyen-Sanz, Yolanda; Fitzsimmons, Jessica N. [Department of Earth, Atmospheric, and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Zhang Ruifeng [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China); Kayser, Richard A. [Department of Earth, Atmospheric, and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2011-02-07

    A simple and accurate low-blank method has been developed for the analysis of total dissolved copper, cadmium, lead, and iron in a small volume (1.3-1.5 mL per element) of seawater. Pre-concentration and salt-separation of a stable isotope spiked sample are achieved by single batch extraction onto nitrilotriacetate (NTA)-type Superflow chelating resin beads (100-2400 beads depending on the element). Metals are released into 0.1-0.5 M HNO{sub 3}, and trace metal isotope ratios are determined by ICPMS. The benefit of this method compared to our previous Mg(OH){sub 2} coprecipitation method is that the final matrix is very dilute so cone-clogging and matrix sensitivity suppression are minimal, while still retaining the high accuracy of the isotope dilution technique. Recovery efficiencies are sensitive to sample pH, number of resin beads added, and the length of time allowed for sample-resin binding and elution; these factors are optimized for each element to yield the highest recovery. The method has a low procedural blank and high sensitivity sufficient for the analysis of pM-nM open-ocean trace metal concentrations. Application of this method to samples from the Bermuda Atlantic Time-Series Study station provides oceanographically consistent Cu, Cd, Pb, and Fe profiles that are in good agreement with other reliable data for this site. In addition, the method can potentially be modified for the simultaneous analysis of multiple elements, which will be beneficial for the analysis of large number of samples.

  19. Analysis of trace metals (Cu, Cd, Pb, and Fe) in seawater using single batch nitrilotriacetate resin extraction and isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lee, Jong-Mi; Boyle, Edward A.; Echegoyen-Sanz, Yolanda; Fitzsimmons, Jessica N.; Zhang Ruifeng; Kayser, Richard A.

    2011-01-01

    A simple and accurate low-blank method has been developed for the analysis of total dissolved copper, cadmium, lead, and iron in a small volume (1.3-1.5 mL per element) of seawater. Pre-concentration and salt-separation of a stable isotope spiked sample are achieved by single batch extraction onto nitrilotriacetate (NTA)-type Superflow chelating resin beads (100-2400 beads depending on the element). Metals are released into 0.1-0.5 M HNO 3 , and trace metal isotope ratios are determined by ICPMS. The benefit of this method compared to our previous Mg(OH) 2 coprecipitation method is that the final matrix is very dilute so cone-clogging and matrix sensitivity suppression are minimal, while still retaining the high accuracy of the isotope dilution technique. Recovery efficiencies are sensitive to sample pH, number of resin beads added, and the length of time allowed for sample-resin binding and elution; these factors are optimized for each element to yield the highest recovery. The method has a low procedural blank and high sensitivity sufficient for the analysis of pM-nM open-ocean trace metal concentrations. Application of this method to samples from the Bermuda Atlantic Time-Series Study station provides oceanographically consistent Cu, Cd, Pb, and Fe profiles that are in good agreement with other reliable data for this site. In addition, the method can potentially be modified for the simultaneous analysis of multiple elements, which will be beneficial for the analysis of large number of samples.

  20. The isotopic contamination in electromagnetic isotope separators; La contagion isotopique dans les separateurs electromagnetiques d'isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Cassignol, Ch. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In the early years of isotope separation, and in particular electromagnetic isotope separation, needs for rapid results have conducted to empiric research. This paper describes fundamental research on the electromagnetic isotope separation to a better understanding of isotope separators as well as improving the performances. Focus has been made on the study of the principle of isotope contamination and the remedial action on the separator to improve the isotope separation ratio. In a first part, the author come back to the functioning of an electromagnetic separator and generalities on isotope contamination. Secondly, it describes the two stages separation method with two dispersive apparatus, an electromagnetic separation stage followed by an electrostatic separation stage, both separated by a diaphragm. The specifications of the electrostatic stage are given and its different settings and their consequences on isotope separation are investigated. In a third part, mechanisms and contamination factors in the isotope separation are discussed: natural isotope contamination, contamination by rebounding on the collector, contamination because of a low resolution, contamination by chromatism and diffusion effect, breakdown of condenser voltage. Analysis of experimental results shows the diffusion as the most important contamination factor in electromagnetic isotope separation. As contamination factors are dependent on geometric parameters, sector angle, radius of curvature in the magnetic field and clearance height are discussed in a fourth part. The better understanding of the mechanism of the different contamination factors and the study of influential parameters as pressure and geometric parameters lead to define a global scheme of isotope contamination and determinate optima separator design and experimental parameters. Finally, the global scheme of isotope contamination and hypothesis on optima specifications and experimental parameters has been checked during a

  1. Effect of natural West African phosphates on phosphorus uptake by Agrostis and on isotopically dilutable phosphorus (L-value) in five tropical soils

    International Nuclear Information System (INIS)

    Pichot, J.; Truong, B.; Beunard, P.

    1979-01-01

    Six natural West African phosphates are compared with a weak Tunisian phosphate and triple superphosphate in five types of tropical soil. The study consists of a pot experiment using Agrostis as the test plant, over several cuttings, in order to evaluate the uptake of phosphorus by plants and the isotopically dilutable phosphorus of the soil (L-value). The results show that there are very great differences between phosphates from the points of view of speed and degree of solubilization and that the L-value is a good criterion for assessing these differences. (author)

  2. Determination of fission products and actinides by inductively coupled plasma-mass spectrometry using isotope dilution analysis. A study of random and systematic errors

    International Nuclear Information System (INIS)

    Ignacio Garcia Alonso, Jose

    1995-01-01

    The theory of the propagation of errors (random and systematic) for isotope dilution analysis (IDA) has been applied to the analysis of fission products and actinide elements by inductively coupled plasma-mass spectrometry (ICP-MS). Systematic errors in ID-ICP-MS arising from mass-discrimination (mass bias), detector non-linearity and isobaric interferences in the measured isotopes have to be corrected for in order to achieve accurate results. The mass bias factor and the detector dead-time can be determined by using natural elements with well-defined isotope abundances. A combined method for the simultaneous determination of both factors is proposed. On the other hand, isobaric interferences for some fission products and actinides cannot be eliminated using mathematical corrections (due to the unknown isotope abundances in the sample) and a chemical separation is necessary. The theory for random error propagation in IDA has been applied to the determination of non-natural elements by ICP-MS taking into account all possible sources of uncertainty with pulse counting detection. For the analysis of fission products, the selection of the right spike isotope composition and spike to sample ratio can be performed by applying conventional random propagation theory. However, it has been observed that, in the experimental determination of the isotope abundances of the fission product elements to be determined, the correction for mass-discrimination and the correction for detector dead-time losses contribute to the total random uncertainty. For the instrument used in the experimental part of this study, it was found that the random uncertainty on the measured isotope ratios followed Poisson statistics for low counting rates whereas, for high counting rates, source instability was the main source of error

  3. Labile pools of Pb in vegetable-growing soils investigated by an isotope dilution method and its influence on soil pH.

    Science.gov (United States)

    Xie, Hong; Huang, Zhi-Yong; Cao, Ying-Lan; Cai, Chao; Zeng, Xiang-Cheng; Li, Jian

    2012-08-01

    Pollution of Pb in the surface of agricultural soils is of increasing concern due to its serious impact on the plant growth and the human health through the food chain. However, the mobility, activity and bioavailability of Pb rely mainly on its various chemical species in soils. In the present study, E and L values, the labile pools of isotopically exchangeable Pb, were estimated using the method of isotope dilution in three vegetable-growing soils. The experiments involved adding a stable enriched isotope ((206)Pb > 96%) to a soil suspension and to soils in which plants are subsequently grown, the labile pools of Pb were then estimated by measuring the isotopic composition of Pb in soil solutions and in the plant tissues, respectively. In addition, the correlation of E values and soil pH was investigated at the ranges of pH 4.5-7.0. The amount of labile Pb in soils was also estimated using different single chemical extractants and a modified BCR approach. The results showed that after spiking the enriched isotopes of (206)Pb (>96%) for 24 hours an equilibration of isotopic exchanges in soil suspensions was achieved, and the isotope ratios of (208)Pb/(206)Pb measured at that time was used for calculating the E(24 h) values. The labile pools of Pb by %E(24 h) values, ranging from 53.2% to 61.7% with an average 57%, were found to be significantly higher (p soil pH was found in the tested soil sample. The results indicate that the %E(24 h) value can more rapidly and easily predict the labile pools of Pb in soils compared with L values, but it might be readily overestimated because of the artificial soil acidity derived from the spiked isotopic tracer and the excess of spiked enriched isotopes. The results also suggest that the amounts of Pb extracted with EDTA and the Σ(BCR) values extracted with the modified BCR approach are helpful to detect the labile pools of Pb in soils. In addition, the negative correlation between soil pH and the labile pools of Pb in soils

  4. Quantitation using a stable isotope dilution assay (SIDA) and thresholds of taste-active pyroglutamyl decapeptide ethyl esters (PGDPEs) in sake.

    Science.gov (United States)

    Hashizume, Katsumi; Ito, Toshiko; Igarashi, Shinya

    2017-03-01

    A stable isotope dilution assay (SIDA) for two taste-active pyroglutamyl decapeptide ethyl esters (PGDPE1; (pGlu)LFGPNVNPWCOOC 2 H 5 , PGDPE2; (pGlu)LFNPSTNPWCOOC 2 H 5 ) in sake was developed using deuterated isotopes and high-resolution mass spectrometry. Recognition thresholds of PGDPEs in sake were estimated as 3.8 μg/L for PGDPE1 and 8.1 μg/L for PGDPE2, evaluated using 11 student panelists aged in their twenties. Quantitated concentrations in 18 commercial sake samples ranged from 0 to 27 μg/L for PGDPE1 and from 0 to 202 μg/L for PGDPE2. The maximum levels of PGDPE1 and PGDPE2 in the sake samples were approximately 8 and 25 times higher than the estimated recognition thresholds, respectively. The results indicated that PGDPEs may play significant sensory roles in the sake. The level of PGDPEs in unpasteurized sake samples decreased during storage for 50 days at 6 °C, suggesting PGDPEs may be enzymatically decomposed.

  5. Principles of isotopic analysis by mass spectrometry

    International Nuclear Information System (INIS)

    Herrmann, M.

    1980-01-01

    The use of magnetic sector field mass spectrometers in isotopic analysis, especially for nitrogen gas, is outlined. Two measuring methods are pointed out: the scanning mode for significantly enriched samples and the double collector method for samples near the natural abundance of 15 N. The calculation formulas are derived and advice is given for corrections. (author)

  6. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

    International Nuclear Information System (INIS)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G.; Prohaska, Thomas

    2007-01-01

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for 35 Cl + to more than 6 x 10 5 cps for 238 U + for 1 μg of trace element per gram of coal sample. Detection limits vary from 450 ng g -1 for chlorine and 18 ng g -1 for sulfur to 9.5 pg g -1 for mercury and 0.3 pg g -1 for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. (orig.)

  7. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Prohaska, Thomas; Heumann, Klaus G

    2007-10-01

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for (35)Cl+ to more than 6 x 10(5) cps for (238)U+ for 1 microg of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.

  8. The measurement of the isotope ratios and concentrations of zinc by thermal ionization mass spectrometry using double isotope dilution

    International Nuclear Information System (INIS)

    Deng Zhongguo

    1994-01-01

    The isotope ratios and concentrations of zinc are measured by silicagel-thermal ionization mass spectrometry using the double isotope spikers. The double isotope spikers ( 70 Zn and 67 Zn-enriched isotopes) are used to correct the isotope mass fractionation for the zinc isotope ratios, and to certify the zinc concentrations in the unknown samples. The zinc concentrations of these double isotope spikers are surveyed by a spiker made of pure (99.99%) natural zinc metal powder. The correcting factors (f a , f t and f n ) of the zinc isotope ratios in the spiked mixture, spike and unspiked samples for the isotope mass fractionation, and the spike-to-unspiked ratios (X r ) of the zinc isotope r in the spiked mixture samples can be obtained to solve the matrix equations by numerical approximation. The natural zinc isotope ratios are: 64 Zn/ 67 Zn = 11.8498, 66 Zn/ 67 Zn = 6.7977, 68 Zn/ 67 Zn = 4.5730 and 70 Zn/ 67 Zn = 0.1520. The uncertainties determined of the isotope ratios and concentrations of zinc are +- 0.16% and +-0.31%, respectively

  9. Interlaboratory determinations of isotopically enriched metals by field desorption mass spectroscopy

    International Nuclear Information System (INIS)

    Bahr, U.; Schulten, H.R.; Achenbach, C.; Ziskoven, R.

    1982-01-01

    The isotopic distribution of stable isotopes in six enriched metals (calcium, copper, barium, rubidium, strontium and thallium) has been determined by field desorption mass spectrometry. A first evaluation of the interlaboratory reproducibility of the application of this method for trace determination of metals was made using three different types of mass spectrometers in three different laboratories. The standard deviations for the most abundant isotopes of the metals investigated are between +-0.1 and +-0.5%. Within these standard deviations, the values obtained by the three mass spectrometry groups are the same. To support the accuracy of our quantification, thermal ionization mass spectrometry has been employed and confirms the results of the field desorption method. (orig.) [de

  10. Theoretical modeling of diluted antiferromagnetic systems

    International Nuclear Information System (INIS)

    Pozo, J; Elgueta, R; Acevedo, R

    2000-01-01

    Some magnetic properties of a Diluted Antiferromagnetic System (DAFS) are studied. The model of the two sub-networks for antiferromagnetism is used and a Heisenberg Hamiltonian type is proposed, where the square operators are expressed in terms of boson operators with the approach of spin waves. The behavior of the diluted system's fundamental state depends basically on the competition effect between the anisotropy field and the Weiss molecular field. The approach used allows the diluted system to be worked for strong anisotropies as well as when these are very weak

  11. Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinations of platinum group elements (Pt, Pd, Ru, Ir) in environmental samples.

    Science.gov (United States)

    Müller, M; Heumann, K G

    2000-09-01

    An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.

  12. Biological nitrogen fixation in Crotalaria species estimated using the 15N isotope dilution method

    International Nuclear Information System (INIS)

    Samba, R.T.; Neyra, M.; Gueye, M.; Sylla, S.N.; Ndoye, I.; Dreyfus, B.

    2002-01-01

    Growing in Senegal by using 15 N direct isotope dilution technique. Two non-fixing plants, Senna obtusifolia and Senna occidentalis served as reference plants. The amount of nitrogen fixed two months after planting was obtained using the average of the two reference plants. The atom % 15 N excess in the Crotalaria species was significantly lower than that of the reference plants, indicating that significant nitrogen fixation occurred in the three plants. Significant differences were observed between the Crotalaria species; C. ochroleuca yielded more dry matter weight and total nitrogen than did C. perrottetti and C. retusa. The % nitrogen derived from atmosphere (%Ndfa) in leaves and stems was also higher in C. ochroleuca. There was no significant difference in %Ndfa in the whole plant between the three Crotalaria species (47% to 53%). In contrast, interspecific variability was observed based on the %Ndfa. C. ochroleuca significantly exhibited the higher amount of total nitrogen fixed, equivalent to 83 kg of nitrogen fixed per hectare. Based on these data, it was concluded that C. ochroleuca could be used in multiple cropping systems in Senegal for making more nitrogen available to other plants. (author)

  13. Determination of iodine in oyster tissue by isotope dilution laser resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Fassett, J.D.; Murphy, T.J.

    1990-01-01

    The technique of laser resonance ionization mass spectrometry has been combined with isotope dilution analysis to determine iodine in oyster tissue. The long-lived radioisotope, 129I, was used to spike the samples. Samples were equilibrated with the 129I, wet ashed under controlled conditions, and iodine separated by coprecipitation with silver chloride. The analyte was dried as silver ammonium iodide upon a tantalum filament from which iodine was thermally desorbed in the resonance ionization mass spectrometry instrument. A single-color, two-photon resonant plus one-photon ionization scheme was used to form positive iodine ions. Long-lived iodine signals were achieved from 100 ng of iodine. The precision of 127I/129I measurement has been evaluated by replicate determinations of the spike, the spike calibration samples, and the oyster tissue samples and was 1.0%. Measurement precision among samples was 1.9% for the spike calibration and 1.4% for the oyster tissue. The concentration of iodine determined in SRM 1566a, Oyster Tissue, was 4.44 micrograms/g with an estimate of the overall uncertainty for the analysis of +/- 0.12 microgram/g

  14. Isotope dilution analysis for the determination of zinc in blood samples of diabetic patients

    International Nuclear Information System (INIS)

    Garg, A.N.; Kumar, A.; Maheshwari, G.; Sharma, S.

    2005-01-01

    Isotope dilution analysis (IDA) based on solvent extraction has been developed for the determination of zinc in the blood of diabetic patients and healthy adults as controls. The method using 65 Zn as a tracer is based on the formation of a red colored complex with dithizone in chloroform which is measured by counting of the 1115 keV γ-rays by gamma-ray spectrometry. Various extraction parameters such as pH, nature of solvent and amount of reagent were optimized. Zinc concentration in diabetic patients (n = 10) was found in a much wider range (1.5-157 μg/ml) compared to those in healthy adults (3.1-95.9 μg/ml for n = 5). t-Test of data shows 80-90% confidence limits. A comparison of mean values, 28.5 ± 48.5 μg/ml for diabetics and 33.1 ± 34.5 μg/ml for controls shows 13.9% lower zinc concentration in diabetics. No correlation was found with eating (vegetarian/nonvegetarian)/drinking or smoking habits, but in general, females showed somewhat lower concentration compared to those in males though population size in each case was very small. (author)

  15. Simultaneous speciation of mercury and butyltin compounds in natural waters and snow by propylation and species-specific isotope dilution mass spectrometry analysis

    Energy Technology Data Exchange (ETDEWEB)

    Monperrus, M.; Tessier, E.; Veschambre, S.; Amouroux, D.; Donard, O. [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, CNRS UMR 5034, Helioparc, Pau (France)

    2005-02-01

    A robust method has been developed for simultaneous determination of mercury and butyltin compounds in aqueous samples. This method is capable of providing accurate results for analyte concentrations in the picogram per liter to nanogram per liter range. The simultaneous determination of the mercury and tin compounds is achieved by species-specific isotope dilution, derivatization, and gas chromatography-inductively coupled plasma mass spectrometer (GC-ICP-MS). In derivatization by ethylation and propylation, reaction conditions such as pH and the effect of chloride were carefully studied. Ethylation was found to be more sensitive to matrix effects, especially for mercury compounds. Propylation was thus the preferred derivatization method for simultaneous determination of organomercury and organotin compounds in environmental samples. The analytical method is highly accurate and precise, with RSD values of 1 and 3% for analyte concentrations in the picogram per liter to nanogram per liter range. By use of cleaning procedures and SIDMS blank measurements, detection limits in the range 10-60 pg L{sup -1} were achieved; these are suitable for determination of background levels of these contaminants in environmental samples. This was demonstrated by using the method for analysis of real snow and seawater samples. This work illustrates the great advantage of species-specific isotope dilution for the validation of an analytical speciation method - the possibility of overcoming species transformations and non-quantitative recovery. Analysis time is saved by use of the simultaneous method, because of the use of a single sample-preparation procedure and one analysis. (orig.)

  16. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO2 solid-phase extraction.

    Science.gov (United States)

    García-Ruiz, Silvia; Petrov, Ivan; Vassileva, Emilia; Quétel, Christophe R

    2011-11-01

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 μg L(-1) depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below μg L(-1) level in natural water. It is based on solid-phase extraction using TiO(2) nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 ± 2.8 ng kg(-1) (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg(-1)). We applied the developed method to the groundwater and wastewater

  17. Electromagnetic separator for light and middle isotope elements

    International Nuclear Information System (INIS)

    Bernas, R.

    1952-01-01

    We describe a separator of isotope with a 60 deg magnetic sector that permits, thanks to a process of neutralization of the space charge, to use efficiently intense ion beams. The ion source for solid is essentially constituted by a discharge of hot cathode in a magnetic field and provides an ion beam focused of more than 10 mA. The result of the first separations (Zn, Sb, Hg) indicates that the isotopes of various elements can be obtained in quantities varying from 10 to 100 mg/24 hours. (author) [fr

  18. Isotopic dilution methods to determine the gross transformation rates of nitrogen, phosphorus, and sulfur in soil: a review of the theory, methodologies, and limitations

    International Nuclear Information System (INIS)

    Di, H. J.; Cameron, K. C.; McLaren, R. G.

    2000-01-01

    The rates at which nutrients are released to, and removed from, the mineral nutrient pool are important in regulating the nutrient supply to plants. These nutrient transformation rates need to be taken into account when developing nutrient management strategies for economical and sustainable production. A method that is gaining popularity for determining the gross transformation rates of nutrients in the soil is the isotopic dilution technique. The technique involves labelling a soil mineral nutrient pool, e.g. NH 4 + , NO 3 - , PO 4 3- , or SO 4 2- , and monitoring the changes with time of the size of the labelled nutrient pool and the excess tracer abundance (atom %, if stable isotope tracer is used) or specific activity (if radioisotope is used) in the nutrient pool. Because of the complexity of the concepts and procedures involved, the method has sometimes been used incorrectly, and results misinterpreted. This paper discusses the isotopic dilution technique, including the theoretical background, the methodologies to determine the gross flux rates of nitrogen, phosphorus, and sulfur, and the limitations of the technique. The assumptions, conceptual models, experimental procedures, and compounding factors are discussed. Possible effects on the results by factors such as the uniformity of tracer distribution in the soil, changes in soil moisture content, substrate concentration, and aeration status, and duration of the experiment are also discussed. The influx and out-flux transformation rates derived from this technique are often contributed by several processes simultaneously, and thus cannot always be attributed to a particular nutrient transformation process. Despite the various constraints or possible compounding factors, the technique is a valuable tool that can provide important quantitative information on nutrient dynamics in the soil-plant system. Copyright (2000) CSIRO Publishing

  19. Negative chemical ionization GC/MS determination of nitrite and nitrate in seawater using exact matching double spike isotope dilution and derivatization with triethyloxonium tetrafluoroborate.

    Science.gov (United States)

    Pagliano, Enea; Meija, Juris; Sturgeon, Ralph E; Mester, Zoltan; D'Ulivo, Alessandro

    2012-03-06

    The alkylation of nitrite and nitrate by triethyloxonium tetrafluoroborate allows determination of their ethyl esters by headspace gas chromatography/mass spectrometry (GC/MS). In the present study, significant improvement in analytical performance is achieved using negative chemical ionization providing detection limits of 150 ng/L for NO(2)(-) and 600 ng/L for NO(3)(-), an order of magnitude better than those achieved using electron impact ionization. The derivatization procedure was optimized and alkaline conditions adopted to minimize conversion of nitrite to nitrate (determined to be 0.07% at 100 mg/L NO(2)(-)) and to avoid the exchange of oxygen between the analytes and the solvent (water). Quantitation entails use of isotopically enriched standards (N(18)O(2)(-) and (15)NO(3)(-)), which also permits monitoring of potential conversion from nitrite to nitrate during the analysis (double spike isotope dilution).

  20. Liquid--vapor isotope fractionation factors in argon--krypton binary mixtures

    International Nuclear Information System (INIS)

    Lee, M.W.; Neufeld, P.; Bigeleisen, J.

    1977-01-01

    An equilibrium isotope effect has been studied as a continuous function of the potential field acting on the atom undergoing isotopic exchange. This has been accomplished through a study of the liquid vapor isotope fractionation factors for both, 36 Ar/ 40 Ar and 80 Kr/ 84 Kr in a series of binary mixtures which span the range between the pure components at 117.5 0 K. The 36 Ar/ 40 Ar fractionation factor increases (linearly) from (lnα)2.49 x 10 -3 in pure liquid argon to 2.91 x 10 -3 in an infinitely dilute solution in liquid krypton. Conversely, the 80 Kr/ 84 Kr fractionation factor decreases (linearly) from (lnα)0.98 x 10 -3 in pure liquid krypton to 0.64 x 10 -3 in an infinetely dilute solution in pure liquid argon. The mean force constants 2 U>/sub c/ on both argon and krypton atoms in the mixtures are derived from the respective isotope fractionation factors.The mean force constants for argon and krypton as a function of composition have been calculated by a modified corresponding states theory which uses the pure liquids as input parameters. The discrepancy is 8 percent at X/sub Ar/ + O. A systematic set of calculations has been made of 2 U> (Ar) and 2 U> (Kr) as a function of composition using radial distribution functions generated by the Weeks--Chandler--Anderson perturbation theory

  1. Mercury speciation analysis in seafood by species-specific isotope dilution: method validation and occurrence data

    Energy Technology Data Exchange (ETDEWEB)

    Clemens, Stephanie; Guerin, Thierry [Agence Nationale de Securite Sanitaire de l' Alimentation, Laboratoire de Securite des Aliments de Maisons-Alfort, Unite des Contaminants Inorganiques et Mineraux de l' Environnement, ANSES, Maisons-Alfort (France); Monperrus, Mathilde; Donard, Olivier F.X.; Amouroux, David [IPREM UMR 5254 CNRS - Universite de Pau et des Pays de l' Adour, Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, Institut des Sciences Analytiques et de Physico-chimie pour l' Environnement et les Materiaux, Pau Cedex (France)

    2011-11-15

    Methylmercury (MeHg) and total mercury (THg) in seafood were determined using species-specific isotope dilution analysis and gas chromatography combined with inductively coupled plasma mass spectrometry. Sample preparation methods (extraction and derivation step) were evaluated on certified reference materials using isotopically enriched Hg species. Solid-liquid extraction, derivation by propylation and automated agitation gave excellent accuracy and precision results. Satisfactory figures of merit for the selected method were obtained in terms of limit of quantification (1.2 {mu}g Hg kg{sup -1} for MeHg and 1.4 {mu}g Hg kg{sup -1} for THg), repeatability (1.3-1.7%), intermediate precision reproducibility (1.5% for MeHg and 2.2% for THg) and trueness (bias error less than 7%). By means of a recent strategy based on accuracy profiles ({beta}-expectation tolerance intervals), the selected method was successfully validated in the range of approximately 0.15-5.1 mg kg{sup -1} for MeHg and 0.27-5.2 mg kg{sup -1} for THg. Probability {beta} was set to 95% and the acceptability limits to {+-}15%. The method was then applied to 62 seafood samples representative of consumption in the French population. The MeHg concentrations were generally low (1.9-588 {mu}g kg{sup -1}), and the percentage of MeHg varied from 28% to 98% in shellfish and from 84% to 97% in fish. For all real samples tested, methylation and demethylation reactions were not significant, except in one oyster sample. The method presented here could be used for monitoring food contamination by MeHg and inorganic Hg in the future to more accurately assess human exposure. (orig.)

  2. Measurement of 2-carboxyarabinitol 1-phosphate in plant leaves by isotope dilution

    International Nuclear Information System (INIS)

    Moore, B.D.; Kobza, J.; Seemann, J.R.

    1991-01-01

    The level of 2-carboxyarabinitol 1-phosphate (CA1P) in leaves of 12 species was determined by an isotope dilution assay. 14 C-labeled standard was synthesized from [2- 14 C]carboxyarabinitol 1,5-bisphosphate using acid phosphatase, and was added at the initial point of leaf extraction. Leaf CA1P was purified and its specific activity determined. CA1P was found in dark-treated leaves of all species examined, including spinach (Spinacea oleracea), wheat (Triticum aestivum), Arabidopsis thaliana, and maize (Zea mays). The highest amounts were found in bean (Phaseolus vulgaris) and petunia (Petunia hybrida), which had 1.5 to 1.8 moles CA1P per mole ribulose 1,5-bisphosphate carboxylase catalytic sites. Most species had intermediate amounts of CA1P (0.2 to 0.8 mole CA1P per mole catalytic sites). Such intermediate to high levels of CA1P support the hypothesis that CA1P functions in many species as a light-dependent regulator of ribulose 1,5-bisphosphate carboxylase activity and whole leaf photosynthetic CO 2 assimilation. However, CA1P levels in spinach, wheat, and A. thaliana were particularly low (less than 0.09 mole CA1P per mole catalytic sites). In such species, CA1P does not likely have a significant role in regulating ribulose 1,5-bisphosphate carboxylase activity, but could have a different physiological role

  3. Magnetic field and magnetic isotope effects on photochemical reactions

    International Nuclear Information System (INIS)

    Wakasa, Masanobu

    1999-01-01

    By at present exact experiments and the theoretical analysis, it was clear that the magnetic field less than 2 T affected a radical pair reaction and biradical reaction. The radical pair life and the dissipative radical yield showed the magnetic field effects on chemical reactions. The radical pair mechanism and the triplet mechanism were known as the mechanism of magnetic field effects. The radical pair mechanism consists of four mechanisms such as the homogeneous hyperfine interaction (HFC), the delta-g mechanism, the relaxation mechanism and the level cross mechanism. In order to observe the magnetic effects of the radical pair mechanism, two conditions need, namely, the recombination rate of singlet radical pair > the dissipation rate and the spin exchange rate > the dissipation rate. A nanosecond laser photo-decomposition equipment can observe the magnetic field effects. The inversion phenomena of magnetic field effect, isolation of the relaxation mechanism and the delta-g mechanism, the magnetic field effect of heavy metal radical reaction, the magnetic field effect in homogeneous solvent, saturation of delta-g mechanism are explained. The succeeded examples of isotope concentration by the magnetic isotope effect are 17 O, 19 Si, 33 S, 73 Ge and 235 U. (S.Y.)

  4. performance of sorghum grown on a salt affected soil manured with dhaincha plant residues using a 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Al-Ain, F.; Razok, A.; Al-Shamma, M.

    2008-01-01

    A field experiment was conducted on a salt-affected soil to determine the effect of application of three types of Dhaincha (Sesbania aculeata pers.) residues (R, roots; L, shoots; L+R, shoots plus roots) of on the performance of sorghum (Sorghum bicolor L.) using the indirect 15 N isotopic dilution technique. Results indicated that Sesbania residues (L and L+R), used as green manures significantly increased grain yield, dry matter production, N uptake, and water use efficiency of sorghum. Percentages of N derived from residues (%Ndfr) in sorghum ranged from 6.4 to 28%. The N recoveries in sorghum were 52, 19. and 19.7% of the total amount contained in Sesbania roots, shoots and roots plus shoots, respectively. The beneficial effects of Sesbania residues are attributed not only to the additional N availability to the plants, but also to effects on the enhancement of soil N uptake, particularly in the L+R treatment. The findings suggest that the use of Sesbania aculeata residues, as a green manure, can provide a substantial portion of total N in sorghum. In addition, the use of Sesbania green manure in salt-affected soils, as a bio-reclaiming material, can be a promising approach for enhancing plant growth on a sustainable basis. (author)

  5. Determination of gamma-aminobutyric acid in food matrices by isotope dilution hydrophilic interaction chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Zazzeroni, Raniero; Homan, Andrew; Thain, Emma

    2009-08-01

    The estimation of the dietary intake of gamma-aminobutyric acid (GABA) is dependent upon the knowledge of its concentration values in food matrices. To this end, an isotope dilution liquid chromatography-mass spectrometry method has been developed employing the hydrophilic interaction chromatography technique for analyte separation. This approach enabled accurate quantification of GABA in apple, potato, soybeans, and orange juice without the need of a pre- or post-column derivatization reaction. A selective and precise analytical measurement has been obtained with a triple quadrupole mass spectrometer operating in multiple reaction monitoring using the method of standard additions and GABA-d(6) as an internal standard. The concentrations of GABA found in the matrices tested are 7 microg/g of apple, 342 microg/g of potatoes, 211 microg/g of soybeans, and 344 microg/mL of orange juice.

  6. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Ruiyue Yang

    Full Text Available BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. RESULTS: Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. CONCLUSION: A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  7. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material; Analisis de Estano en una Ceniza de Combustion mediante Espectrometria de Masas de Ionizacion Termica con Dilucion Isotopica

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, C; Fernandez, M; Quejido, A L

    2006-07-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs.

  8. Study of the matrix specific mass discrimination effects during inductively coupled plasma mass spectrometry isotope ratio measurements

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, Ch.R.

    2004-01-01

    Sample matrix related effects on mass discrimination during inductively coupled plasma mass spectrometry (ICP-MS) isotope ratio measurements have only been rarely reported. However, they can lead to errors larger than the uncertainty claimed on the ratio results when not properly taken into account or corrected for. These matrix specific affects were experienced during an Isotope Dilution Mass Spectrometry (IDMS) campaign we carried out for the certification of the Cd amount content in some food digest samples (7% acidity and salts content around 450μg g -1 ). Dilution was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This was a significant difference considering that less than 1.5% relative combined uncertainty was eventually estimated for these IDMS measurements. Similar results could be obtained either way after the implementation of necessary corrections. The direct measurement approach associated to a correction for mass discrimination effects using the food digest sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. Consequently, the impact of matrix effects on mass discrimination during isotope ratio measurements with two types of ICP- MS (quadrupole and magnetic sector instruments) was studied for 4 elements (Li, Cu, Cd and Tl). Samples of varying salinity (up to 0.25%) and acidity (up to 7%) characteristics were prepared using isotopic certified reference materials of these elements. The long term and short-term stability, respectively reproducibility and repeatability, of the results, as well as the evolution of the difference to certified ratio values were monitored. As expected the 13 investigated isotopic ratios were all sensitive to variations in salt and acid concentrations. Our experiments also showed that simultaneous variation

  9. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO{sub 2} solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Ruiz, Silvia; Quetel, Christophe R. [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Petrov, Ivan [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Universite Libre de Bruxelles, Department of Earth and Environmental Sciences, Brussels (Belgium); Vassileva, Emilia [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); IAEA-Marine Environment Laboratories, Monaco (Monaco)

    2011-11-15

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 {mu}g L{sup -1} depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below {mu}g L{sup -1} level in natural water. It is based on solid-phase extraction using TiO{sub 2} nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 {+-} 2.8 ng kg{sup -1} (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg{sup -1}). We applied the developed method to the

  10. Daily cortisol production rate in man determined by stable isotope dilution/mass spectrometry

    International Nuclear Information System (INIS)

    Esteban, N.V.; Loughlin, T.; Yergey, A.L.; Zawadzki, J.K.; Booth, J.D.; Winterer, J.C.; Loriaux, D.L.

    1991-01-01

    Growth retardation as well as the development of Cushingoid features in adrenally insufficient patients treated with the currently accepted replacement dose of cortisol (33-41 mumol/day.m2; 12-15 mg/m2.day) prompted us to reevaluate the cortisol production rate (FPR) in normal subjects and patients with Cushing's syndrome, using a recently developed thermospray liquid chromatography-mass spectrometry method. The stable isotope [9,12,12-2H3]cortisol was infused continuously for 31 h at about 5% of the anticipated FPR. Blood samples were obtained at 20-min intervals for 24 h, spun, and pooled in 4-h groups. Tracer dilution in plasma was determined by liquid chromatography/mass spectrometry. The method was validated with controlled infusions in 6 patients with adrenal insufficiency. Results from 12 normal volunteers revealed a FPR of 27.3 +/- 7.5 mumol/day (9.9 +/- 2.7 mg/day) or 15.7 mumol/day.m2; 5.7 mg/m2. day. A previously unreported circadian variation in FPR was observed. Patients with Cushing's syndrome demonstrated unequivocal elevation of FPR and cortisol concentration correlated during each sample period in normal volunteers, indicating that cortisol secretion, rather than metabolism, is mainly responsible for changes in plasma cortisol. Our data suggest that the FPR in normal subjects may be lower than previously believed

  11. User's manual for the ARMLID (Argonne metallic lithium/isotopic dilution) tritium assay system

    International Nuclear Information System (INIS)

    Porges, K.G.; Bretscher, M.M.; Bennett, E.F.; DiIorio, G.; Mattas, R.F.; Lewandowski, E.F.

    1992-08-01

    The Argonne Metallic Lithium - Isotopic Dilution (ARMLID) system described in this report, originally developed at ANL for other purposes, was recently redeployed to measure the tritium production rate (TPR) in a series of US/Japanese collaborative fusion blanket integral experiments, involving large assemblies of fusion breeder blanket materials that were irradiated with a fusion neutron source at FNS/JAERI, Japan. Whereas previous uses of the ARMUD scheme involved just a few samples, its application infusion blanket TPR mapping called for large sample numbers per experiment, implying a commensurate scale of sample fabrication and encapsulation, on one hand, and tritium extraction and counting on the other hand. To shorten the time required for these various tasks, yet still yield reliable and accurate results, both the sample fabrication - encapsulation facility and the tritium extraction system had to be extensively revised from original versions that were designed for accuracy, but not necessarily for speed. The present report describes overall revisions in sufficient detail to serve as a User's Manual for this facility, and/or suggest how a new system might be put together. Either possibility may develop in the near future, in support of ITER design studies. Preliminary and partial descriptions of various aspects and features of the system were presented orally, in the course of annual ANL/JAERI/UCLA ''workshops'', over the last 34 years, as well as elsewhere

  12. On the equivalence of dilute antiferromagnets and ferromagnets in random external fields: Curie-Weiss models

    International Nuclear Information System (INIS)

    Perez, J.F.; Pontin, L.F.; Segundo, J.A.B.

    1985-01-01

    Using a method proposed by van Hemmen the free energy of the Curie-Weiss version of the site-dilute antiferromagnetic Ising model is computed, in the presence of an uniform magnetic field. The solution displays an exact correspondence between this model and the Curie-Weiss version of the Ising model in the presence of a random magnetic field. The phase diagrams are discussed and a tricritical point is shown to exist. (Author) [pt

  13. Simultaneous analysis of polychlorinated biphenyls and polychlorinated naphthalenes by isotope dilution comprehensive two-dimensional gas chromatography high-resolution time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Xia, Dan; Gao, Lirong; Zheng, Minghui; Wang, Shasha; Liu, Guorui

    2016-01-01

    Polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) are listed as persistent organic pollutants (POPs) under the Stockholm Convention. Because they have similar physical and chemical properties, they are coeluted and are usually analyzed separately by different gas chromatography high-resolution mass spectrometry (GC-HRMS) methods. In this study, a novel method was developed for simultaneous analysis of six indicator PCBs, 12 dioxin-like PCBs, and 16 PCNs using isotope dilution comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HRTOF-MS). The method parameters, including the type of GC column, oven temperature program, and modulation period, were systematically optimized. Complete separation of all target analytes and the matrix was achieved with a DB-XLB column in the first dimension and a BPX-70 column in the second dimension. The isotope dilution method was used for quantification of the PCBs and PCNs by GC × GC-HRTOF-MS. The method showed good linearity from 5 to 500 pg μL"−"1 for all the target compounds. The instrumental limit of detection ranged from 0.03 to 0.3 pg μL"−"1 for the 18 PCB congeners and from 0.09 to 0.6 pg μL"−"1 for the 16 PCN congeners. Repeatability for triplicate injections was always lower than 20%. The method was successfully applied to the determination of 18 PCBs present at 0.9–2054 pg g"−"1 and 16 PCNs present at 0.2–15.7 pg g"−"1 in three species of fish. The GC × GC-HRTOF-MS results agreed with those obtained by GC-HRMS. The GC × GC-HRTOF-MS method proved to be a sensitive and accurate technique for simultaneous analysis of the selected PCBs and PCNs. With the excellent chromatographic separation offered by GC × GC and accurate mass measurements offered by HRTOF-MS, this method allowed identification of non-target contaminants in the fish samples, including organochlorine pesticides and polycyclic aromatic

  14. Simultaneous analysis of polychlorinated biphenyls and polychlorinated naphthalenes by isotope dilution comprehensive two-dimensional gas chromatography high-resolution time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Dan [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); University of Chinese Academy of Sciences, Beijing 100085 (China); Gao, Lirong, E-mail: gaolr@rcees.ac.cn [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Zheng, Minghui; Wang, Shasha; Liu, Guorui [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2016-09-21

    Polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) are listed as persistent organic pollutants (POPs) under the Stockholm Convention. Because they have similar physical and chemical properties, they are coeluted and are usually analyzed separately by different gas chromatography high-resolution mass spectrometry (GC-HRMS) methods. In this study, a novel method was developed for simultaneous analysis of six indicator PCBs, 12 dioxin-like PCBs, and 16 PCNs using isotope dilution comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HRTOF-MS). The method parameters, including the type of GC column, oven temperature program, and modulation period, were systematically optimized. Complete separation of all target analytes and the matrix was achieved with a DB-XLB column in the first dimension and a BPX-70 column in the second dimension. The isotope dilution method was used for quantification of the PCBs and PCNs by GC × GC-HRTOF-MS. The method showed good linearity from 5 to 500 pg μL{sup −1} for all the target compounds. The instrumental limit of detection ranged from 0.03 to 0.3 pg μL{sup −1} for the 18 PCB congeners and from 0.09 to 0.6 pg μL{sup −1} for the 16 PCN congeners. Repeatability for triplicate injections was always lower than 20%. The method was successfully applied to the determination of 18 PCBs present at 0.9–2054 pg g{sup −1} and 16 PCNs present at 0.2–15.7 pg g{sup −1} in three species of fish. The GC × GC-HRTOF-MS results agreed with those obtained by GC-HRMS. The GC × GC-HRTOF-MS method proved to be a sensitive and accurate technique for simultaneous analysis of the selected PCBs and PCNs. With the excellent chromatographic separation offered by GC × GC and accurate mass measurements offered by HRTOF-MS, this method allowed identification of non-target contaminants in the fish samples, including organochlorine pesticides and

  15. Determination of inositol 1,4,5-trisphosphate levels in Dictyostelium by isotope dilution assay

    International Nuclear Information System (INIS)

    Van Haastert, P.J.

    1989-01-01

    A commercial isotope dilution assay was used for the determination of Ins(1,4,5)P3 levels in the microorganism Dictyostelium discoideum. Cross-reactivity in the assay was detected with extracts from cells and the medium. The compound which induced this cross-reactivity was tentatively identified as Ins(1,4,5)P3 by (i) codegradation with authentic [ 32 P]Ins(1,4,5)P3 by three specific Ins(1,4,5)P3 phosphatases, and (ii) co-chromatography with authentic [ 32 P]Ins(1,4,5)P3 on HPLC columns. The cellular concentration was estimated as 165 +/- 42 pmol/10(8) cells, yielding a mean intracellular Ins(1,4,5)P3 concentration of 3.3 microM. Dictyostelium cells secrete large amounts of Ins(1,4,5)P3 at a rate of about 10% of the cellular content per minute, yielding about 0.13 microM extracellular Ins(1,4,5)P3 after 15 min in a suspension of 10(8) cells/ml. The chemoattractant cAMP induced a transient increase of the Ins(1,4,5)P3 concentration; the data suggest an intracacellular rise from 3.3 to 5.5 microM with a maximum at 6 s after stimulation

  16. Beneficial use of isotopes

    International Nuclear Information System (INIS)

    Bertel, E.; Stevens, G.H.

    1998-01-01

    The paper gives an outlook on the main isotopes currently used for beneficial applications, provides an overview on geographic distribution of isotope production capabilities and identifies the main suppliers world-wide. It analyses trends in different countries and regions, including the refurbishment and/or replacement of ageing facilities and the implementation of new capabilities. Issues related to adequate supply of isotopes and potential under or over capacity of production for some key products are discussed. The evolution of the isotope production sector is analysed. Issues such as lowering of governmental support to production facilities, emergence of international co-operation and agreements on production capabilities, and developments in non-OECD/NEA countries are addressed. The paper offers some concluding remarks on the importance of maintaining and enhancing beneficial uses of isotopes, the role of government policies, the need for co-operation between countries and between the private and public sectors. The paper addresses the role of international cooperation in making efficient use of existing isotope production capacity and investigates ways for reducing the need for investment in additional capacity. (author)

  17. Radioimmunoassay and liquid-chromatographic analysis for free cortisol in urine compared with isotope dilution-mass spectrometry

    International Nuclear Information System (INIS)

    Lantto, O.

    1982-01-01

    Three different routine methods for analysis for urinary cortisol with those by a highly specific reference method based on isotope dilution-mass spectrometry (I) were compared. A ''high-performance'' liquid-chromatographic method (II) gave the most comparable results (regression coefficient 0.86, intercept 9 nmol/L). For some urines much lower values were obtained by I than by II. Two radioimmunoassay (III) methods, one involving direct assay and one involving extraction, gave less-accurate results (regression coefficients of 1.87 and 1.52 and intercepts of 86 and 12 nmol/L, respectively), although values obtained by III and by I correlated well (r = 0.95-0.99), indicating a relation between the free cortisol and the compounds interfering in III. The apparent accuracy for the extraction method was improved by using as calibration standards urine samples previously assayed by I (regression coefficient 0.90, intercept 6 nmol/L). All four methods investigated showed a statistically significant sex-related difference in 24-h urinary cortisol excretion; evidently such a finding should be a prerequisite in any such method proposed for routine use

  18. Isotopes: technologies, materials and application. II International scientific conference of young scientists, post-graduate students and students. Book of abstracts

    International Nuclear Information System (INIS)

    2015-01-01

    The collection contains materials of abstracts of the conference participants to sum up the experience of research and development in the field of isotope production technologies, the use of compounds specified isotopic composition in different sectors of the economy, as well as the disposal and storage technology of the isotope production wastes. Advanced ideas produce isotopes of rare elements for medicine, microelectronics and nuclear industries are presented. Prospectively projects of scientists of Tomsk Polytechnic University in isotope modifying substances are discussed [ru

  19. Determination of benzene in different food matrices by distillation and isotope dilution HS-GC/MS

    International Nuclear Information System (INIS)

    Medeiros Vinci, Raquel; Canfyn, Michael; De Meulenaer, Bruno; Schaetzen, Thibault de; Van Overmeire, Ilse; De Beer, Jacques; Van Loco, Joris

    2010-01-01

    Benzene is classified by the IARC as carcinogenic to humans. Several sources may contribute for the occurrence of benzene in foods, such as, environmental contamination and the reaction of benzoate salts with ascorbic acid (naturally present or added as food additives). Matrix effect on benzene recovery (e.g. in fatty foods) and artefactual benzene formation from benzoate during analysis in the presence of ascorbate are some of the challenges presented when determining benzene in a wide range of foodstuffs. Design of experiment (DOE) was used to determine the most important variables in benzene recovery from headspace GC/MS. Based on the results of the DOE, a versatile method for the extraction of benzene from all kind of food commodities was developed. The method which consisted of distillation and isotope dilution HS-GC/MS was in-house validated. Artefactual benzene was prevented by addition of a borate buffer solution (pH 11) under distillation conditions. The method presented in this study allows the use of a matrix-independent calibration with detection limits below the legal limit established by the European Council for benzene in drinking water (1 μg L -1 ).

  20. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young

    2005-01-01

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties

  1. Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Yong Hyeon; Park, Ji Youn; Han, Myung Sub; Park, Mi Kyung; Kim, Byung Joo; Lim, Young Ran; Hwang, Eui Jin; So, Hun Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-03-15

    A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

  2. Determination of benzene in different food matrices by distillation and isotope dilution HS-GC/MS

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros Vinci, Raquel [Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); Canfyn, Michael [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium); De Meulenaer, Bruno [Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); Schaetzen, Thibault de; Van Overmeire, Ilse; De Beer, Jacques [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium); Van Loco, Joris, E-mail: Joris.VanLoco@iph.fgov.BE [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium)

    2010-07-05

    Benzene is classified by the IARC as carcinogenic to humans. Several sources may contribute for the occurrence of benzene in foods, such as, environmental contamination and the reaction of benzoate salts with ascorbic acid (naturally present or added as food additives). Matrix effect on benzene recovery (e.g. in fatty foods) and artefactual benzene formation from benzoate during analysis in the presence of ascorbate are some of the challenges presented when determining benzene in a wide range of foodstuffs. Design of experiment (DOE) was used to determine the most important variables in benzene recovery from headspace GC/MS. Based on the results of the DOE, a versatile method for the extraction of benzene from all kind of food commodities was developed. The method which consisted of distillation and isotope dilution HS-GC/MS was in-house validated. Artefactual benzene was prevented by addition of a borate buffer solution (pH 11) under distillation conditions. The method presented in this study allows the use of a matrix-independent calibration with detection limits below the legal limit established by the European Council for benzene in drinking water (1 {mu}g L{sup -1}).

  3. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    Science.gov (United States)

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  4. Crystal fields of dilute Tb, Dy, Ho, or Er in Lu obtained by magnetization measurements

    International Nuclear Information System (INIS)

    Touborg, P.; Hog, J.

    1975-01-01

    Magnetization measurements are reported on single crystals of dilute Tb, Dy, Ho, or Er in Lu. These measurements were performed in the temperature range 1.5--100 K and field range 0--6 T and include measurements of initial susceptibility, isothermal and isofield magnetization, and basal-plane anisotropy. The results show features similar to the corresponding Y-R alloys, where R is a rare earth. Crystal-field and molecular-field parameters could be unabiguously deduced from the experimental data. The effects of crystal-field level broadening were investigated and demonstrated for Ho. Comparison of the Y-R and Lu-R results makes possible an estimate of the crystal-field parameters in the pure-rare-earth metals

  5. Gas chromatography/ion trap mass spectrometry applied for the analysis of triazine herbicides in environmental waters by an isotope dilution technique

    International Nuclear Information System (INIS)

    Cai Zongwei; Wang Dongli; Ma, W.T.

    2004-01-01

    A gas chromatography/ion trap mass spectrometry method was developed for the analysis of simazine, atrazine, cyanazine, as well as the degradation products of atrazine, such as deethylatrazine and deisopropylatrazine in environmental water samples. Isotope dilution technique was applied for the quantitative analysis of atrazine in water at low ng/l levels. One liter of water sample spiked with stable isotope internal standard atrazine-d 5 was extracted with a C 18 solid-phase extraction cartridge. The analysis was performed on an ion trap mass spectrometer operated in MS/MS method. The extraction recoveries were in the range of 83-94% for the triazine herbicides in water at the concentrations of 24, 200, and 1000 ng/l, while poor recoveries were obtained for the degradation products of atrazine. The relative standard deviation (R.S.D.) were within the range of 3.2-16.1%. The detection limits of the method were between 0.75 and 12 ng/l when 1 l of water was analyzed. The method was successfully applied to analyze environmental water samples collected from a reservoir and a river in Hong Kong for atrazine detected at concentrations between 3.4 and 26 ng/l

  6. Partitioning evapotranspiration fluxes with water stable isotopic measurements: from the lab to the field

    Science.gov (United States)

    Quade, M. E.; Brueggemann, N.; Graf, A.; Rothfuss, Y.

    2017-12-01

    Water stable isotopes are powerful tools for partitioning net into raw water fluxes such as evapotranspiration (ET) into soil evaporation (E) and plant transpiration (T). The isotopic methodology for ET partitioning is based on the fact that E and T have distinct water stable isotopic compositions, which in turn relies on the fact that each flux is differently affected by isotopic kinetic effects. An important work to be performed in parallel to field measurements is to better characterize these kinetic effects in the laboratory under controlled conditions. A soil evaporation laboratory experiment was conducted to retrieve characteristic values of the kinetic fractionation factor (αK) under varying soil and atmospheric water conditions. For this we used a combined soil and atmosphere column to monitor the soil and atmospheric water isotopic composition profiles at a high temporal and vertical resolution in a nondestructive manner by combining micro-porous membranes and laser spectroscopy. αK was calculated by using a well-known isotopic evaporation model in an inverse mode with the isotopic composition of E as one input variable, which was determined using a micro-Keeling regression plot. Knowledge on αK was further used in the field (Selhausen, North Rhine-Westphalia, Germany) to partition ET of catch crops and sugar beet (Beta vulgaris) during one growing season. Soil and atmospheric water isotopic profiles were measured automatically across depths and heights following a similar modus operandi as in the laboratory experiment. Additionally, a newly developed continuously moving elevator was used to obtain water vapor isotopic composition profiles with a high vertical resolution between soil surface, plant canopy and atmosphere. Finally, soil and plant samples were collected destructively to provide a comparison with the traditional isotopic methods. Our results illustrate the changing proportions of T and E along the growing season and demonstrate the

  7. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion.

    Science.gov (United States)

    Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.

  8. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion

    Energy Technology Data Exchange (ETDEWEB)

    Heilmann, Jens; Boulyga, Sergei F.; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany)

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous {sup 34}S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of {sup 32}S/{sup 34}S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 {mu}g g{sup -1}) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 {mu}g g{sup -1} were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods. (orig.)

  9. Isotope derived criteria for the measurement of soil and fertilizer micronutrient availability

    International Nuclear Information System (INIS)

    Tiller, K.G.

    1975-01-01

    Field experiments on long-lived gamma-emitting isotopes such as zinc-65 are unlikely to be acceptable because of health hazards, costs, and long-term losses of experimental field sites after completion of the trials. The use of glasshouse experiments for the assessment, by isotopic dilution procedures, of the efficiencies of different fertilizer formulations and their agronomic use is more advantageous. The measurement of nutrient absorbed from the fertilizer need not be restricted to the use of radioactively labelled fertilizers with its attendant technological problems in manufacture, transport, etc. Efficiency of locally available fertilizers, farm and industrial byproducts, could be related to the labelled native soil source of zinc. The dose rate of carrier-free zinc required can be minimized by limiting pot size and restricting fertilizer rates to realistic levels. Radioisotope derived criteria, while clearly valuable in rice micronutrient studies, require complementary field studies involving soil and plant analysis and fertilizer evaluation under conditions of local farm management

  10. Isotopic Abundance and Chemical Purity Analysis of Stable Isotope Deuterium Labeled Sudan I

    Directory of Open Access Journals (Sweden)

    CAI Yin-ping;LEI Wen;ZHENG Bo;DU Xiao-ning

    2014-02-01

    Full Text Available It is important that to analysis of the isotopic abundance and chemical purity of Sudan I-D5, which is the internal standard of isotope dilution mass spectrometry. The isotopic abundance of Sudan I-D5 is detected by “mass cluster” classification method and LC-MS. The repeatability and reproducibility experiments were carried out by using different mass spectrometers and different operators. The RSD was less than 0.1%, so the repeatability and reproducibility were satisfactory. The accuracy and precision of the isotopic abundance analysis method was good with the results of F test and t test. The high performance liquid chromatography (HPLC had been used for detecting the chemical purity of Sudan I-D5 as external standard method.

  11. Numerical simulation of solute trapping phenomena using phase-field solidification model for dilute binary alloys

    Directory of Open Access Journals (Sweden)

    Henrique Silva Furtado

    2009-09-01

    Full Text Available Numerical simulation of solute trapping during solidification, using two phase-field model for dilute binary alloys developed by Kim et al. [Phys. Rev. E, 60, 7186 (1999] and Ramirez et al. [Phys. Rev. E, 69, 05167 (2004] is presented here. The simulations on dilute Cu-Ni alloy are in good agreement with one dimensional analytic solution of sharp interface model. Simulation conducted under small solidification velocity using solid-liquid interface thickness (2λ of 8 nanometers reproduced the solute (Cu equilibrium partition coefficient. The spurious numerical solute trapping in solid phase, due to the interface thickness was negligible. A parameter used in analytical solute trapping model was determined by isothermal phase-field simulation of Ni-Cu alloy. Its application to Si-As and Si-Bi alloys reproduced results that agree reasonably well with experimental data. A comparison between the three models of solute trapping (Aziz, Sobolev and Galenko [Phys. Rev. E, 76, 031606 (2007] was performed. It resulted in large differences in predicting the solidification velocity for partition-less solidification, indicating the necessity for new and more acute experimental data.

  12. Introducing AAA-MS, a rapid and sensitive method for amino acid analysis using isotope dilution and high-resolution mass spectrometry.

    Science.gov (United States)

    Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie

    2012-07-06

    Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.

  13. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation triglycerides and total glycerides.

  14. Isotope correlation and mass spectrometry techniques for irradiated fuel assay

    International Nuclear Information System (INIS)

    Deron, S.

    1985-01-01

    This paper outlines the methods used to account for fissionable materials in irradiated nuclear fuel elements entering reprocessing plants. Verification is accomplished at three mass balance stations in the plant. Techniques employed fall into two categories: isotopic and isotope dilution analyses by mass spectometry and isotope correlation techniques. These methods are discussed in some detail

  15. A comparative study on the production rates of VFA and bacteria in the rumen of buffalo and goat estimated by isotope dilution technique

    International Nuclear Information System (INIS)

    Verma, D.N.; Mehra, U.R.; Singh, U.B.; Ranjhan, S.K.

    1977-01-01

    Digestibility trials were conducted on Murrah buffaloes and Barbari goats with rumen cannulae in the rumen to determine the digestibility of the feed constituents and the production rates of bacteria and total VFA were estimated in the rumen by isotope dilution technique. The bacterial cells growth in the rumen was more in goats than buffaloes when fed ad libitum and calculated on equal feed intake, where as, in buffaloes fed on restricted diet equal to the goats the production of bacteria and VFA were higher. Goats converted 54.04 percent of their dietary nitrogen into microbial nitrogen which was more than twice of buffaloes. (author)

  16. An approach for quantification of platinum distribution in tissues by LA-ICP-MS imaging using isotope dilution analysis.

    Science.gov (United States)

    Moraleja, I; Mena, M L; Lázaro, A; Neumann, B; Tejedor, A; Jakubowski, N; Gómez-Gómez, M M; Esteban-Fernández, D

    2018-02-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been revealed as a convenient technique for trace elemental imaging in tissue sections, providing elemental 2D distribution at a quantitative level. For quantification purposes, in the last years several approaches have been proposed in the literature such as the use of CRMs or matrix matched standards. The use of Isotope Dilution (ID) for quantification by LA-ICP-MS has been also described, being mainly useful for bulk analysis but not feasible for spatial measurements so far. In this work, a quantification method based on ID analysis was developed by printing isotope-enriched inks onto kidney slices from rats treated with antitumoral Pt-based drugs using a commercial ink-jet device, in order to perform an elemental quantification in different areas from bio-images. For the ID experiments 194 Pt enriched platinum was used. The methodology was validated by deposition of natural Pt standard droplets with a known amount of Pt onto the surface of a control tissue, where could be quantified even 50pg of Pt, with recoveries higher than 90%. The amount of Pt present in the whole kidney slices was quantified for cisplatin, carboplatin and oxaliplatin-treated rats. The results obtained were in accordance with those previously reported. The amount of Pt distributed between the medullar and cortical areas was also quantified, observing different behavior for the three drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The application of the signal flow graph method to charged-particle optics - the formula derivation of a three-sector isotope separator

    International Nuclear Information System (INIS)

    Lu Hongyou; Zhao Zhiyong; Sun Quinren

    1987-01-01

    A brief introduction of the Signal Flow Graph (SFG) method is given. The application of it to charged-particle optics (CPO) is described. The method has the advantages of simplicity, visualisation and computerisation. An example of the application of SFG is given for the design of a three-sector electromagnetic isotope separator. (orig.)

  18. Multiresidue analysis of persistent organic pollutants in contaminated soil using GC-LRMS, GC-HRMS and isotope dilution analysis

    International Nuclear Information System (INIS)

    Badea, Silviu-Laurentiu; Lundstedt, Staffan; Liljelind, Per; Tysklind, Mats

    2009-01-01

    In this study we evaluated a multiresidue analytical protocol for selected Persistent Organic Pollutants (POPs) in soil, that later can be used in adsorption and leaching studies. The method used was based on Soxhlet extraction and open column chromatographic fractionation and clean-up, as well as liquid-liquid extraction and acetylation for phenolic compounds. Target analytes, i.e. polychlorinated phenols (PCPhs), hexachlorobenzene (HCB), polychlorinated dibenzodioxins and furans (PCDDs/Fs), polychlorinated biphenyl (PCBs) PAHs, were detected and quantified using Gas Chromatography-Low Resolution Mass Spectrometry (GC-LRMS) and Gas Chromatography-High Resolution Mass Spectrometry (GC-HRMS) and isotope dilution methodology. Generally, the results show a good recovery and a low standard deviation for those isomers that have also a 13 C labeled compound present in the sample: 4-mono, 2,4 di, 2,4,5 tri, 2,3,4,5 and penta chlorinated phenols. Our results clearly demonstrate that it is possible to analyse a wide range of compounds in complex soil matrixes. (authors(

  19. The isotope hydrology of the northern well field, Jwaneng diamond mine, Botswana

    International Nuclear Information System (INIS)

    Verhagen, B.Th.; Brook, M.C.

    1989-01-01

    The northern well field supplies the Jwaneng diamond mine with 4.8x10 6 m 3 /a of good quality ground water. Model predictions, based on hydraulic parameters obtained during initial development, were found to have overestimated well field drawdown and have been twice updated in the past seven years. Since 1983, various surveys of environmental isotope levels in the well field ground water were conducted. Over the period of observation, there has been very little change in the initial conclusion that part of the well field contains suprisingly recent ground water. Active recharge, which was suspected from the chemical composition of the ground water, was therefore confirmed, as well as the fact that the ground water body as a whole is dynamic. The isotopic data are discussed in terms of regional information from the surrounding Karoo aquifers. It is shown that earlier theories of remote recharge to the well field are untenable. More recent data on first strike and other water samples obtained during exploring drilling are incorporated. Estimates based on the hydrological picture presented by the isotope data, indicate economically significant local rain recharge. A simple analytical model of well field behaviour shows that this calculated recharge rate brings the modelled drawdowns into the range of actually observed values. 10 refs., 7 figs

  20. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F. [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria); Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Prohaska, Thomas [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria)

    2007-10-15

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for {sup 35}Cl{sup +} to more than 6 x 10{sup 5} cps for {sup 238}U{sup +} for 1 {mu}g of trace element per gram of coal sample. Detection limits vary from 450 ng g{sup -1} for chlorine and 18 ng g{sup -1} for sulfur to 9.5 pg g{sup -1} for mercury and 0.3 pg g{sup -1} for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. (orig.)

  1. Quantification of four artificial sweeteners in Finnish surface waters with isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Perkola, Noora; Sainio, Pirjo

    2014-01-01

    The artificial sweeteners sucralose (SCL), acesulfame (ACS), saccharin (SAC), and cyclamate (CYC) have been detected in environmental waters in Europe and North America. Higher environmental levels are expected in view of the increasing consumption of these food additives. In this study, an isotope-dilution mass spectrometry (IDMS) LC–MS/MS method was developed and validated for quantifying the four artificial sweeteners in boreal lakes (n = 3) and rivers (n = 12). The highest concentrations of ACS, SAC, CYC and SCL were 9,600, 490, 210 and 1000 ng/L, respectively. ACS and SAC were detected in all studied samples, and CYC and SCL in 98% and 56% of the samples. Seasonal trends of ACS and SAC were observed in some rivers. ACS and SCL concentrations in rivers correlated linearly with population equivalents of the wastewater treatment plants in the catchment areas, whereas SAC and CYC concentrations depend more on the source. -- Highlights: • A reliable method for analysing artificial sweeteners in water was validated. • Artificial sweeteners were quantified in boreal rivers and lakes. • Most concentrations were in accordance with previous European studies. • Acesulfame and saccharine concentrations were high in the most contaminated rivers. • Correlation observed between concentrations and mean water throughflow in rivers. -- High concentrations of artificial sweeteners were obtained, which indicates slow or negligible degradation of these compounds in boreal surface waters

  2. Specific heat in diluted magnetic semiconductor quantum ring

    Science.gov (United States)

    Babanlı, A. M.; Ibragimov, B. G.

    2017-11-01

    In the present paper, we have calculated the specific heat and magnetization of a quantum ring of a diluted magnetic semiconductor (DMS) material in the presence of magnetic field. We take into account the effect of Rashba spin-orbital interaction, the exchange interaction and the Zeeman term on the specific heat. We have calculated the energy spectrum of the electrons in diluted magnetic semiconductor quantum ring. Moreover we have calculated the specific heat dependency on the magnetic field and Mn concentration at finite temperature of a diluted magnetic semiconductor quantum ring.

  3. Stable-isotope composition of the water of apple juice

    International Nuclear Information System (INIS)

    Bricout, Jacques; Merlivat, Liliane

    1973-01-01

    By deuterium and oxygen 18 analysis, it was shown that apples' water is enriched in heavier isotopes as compared to rain water. The isotopic composition of the water of reconstituted apple juice is closed to the isotopic content of the rain water used for dilution. Thus, deuterium and oxyden 18 analysis allows a good analytical distinction between natural apple juice and reconstituted juices [fr

  4. A new method for the determination of NO2 traces using isotope dilution and mass spectrometry analysis

    International Nuclear Information System (INIS)

    Stevens, C.; Barat, F.; Nguyen Nghi, H.

    1975-01-01

    A new method for the determination of NO 2 traces, in the order of 1ppb (10 -9 ), in atmosphere and stratosphere is described. The method consists in an isotope dilution technique using 15 NO 2 , followed by the reduction of NO 2 to N 2 and a mass spectrometry analysis. A known amount of 15 NO 2 is added to the air samples. Then, NO 2 is separated from H 2 O, HNO 3 , CO 2 and N 2 O and transferred to a SiO 2 reactor by trapping at -196 deg C. In the reactor NO 2 is reduced to N 2 by reaction with electrolytic Cu heated at 580 deg C. The mass 29/mass 30 ratio corresponding to 15 N 14 N and 15 N 15 N is determined by mass spectrometry. The sensitivity of the method depends on the contamination introduced during the analysis of the sample (reagents, separation and measuring devices). The contamination is reproducible and in the order of 4.5+-0.5 10 -2 mm 3 N 2 [fr

  5. Total and species-specific quantitative analyses of trace elements in sediment by isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Inagaki, Kazumi; Takatsu, Akiko; Yarita, Takashi; Okamoto, Kensaku; Chiba, Koichi

    2009-01-01

    Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the reliable methods for total and species-specific quantitative analysis of trace elements. However, several technical problems (e.g. spectral interference caused from sample constituents) should be overcome to obtain reliable analytical results when environmental samples are analyzed by ID-ICP-MS. In our laboratory, various methods based on ID-ICP-MS have been investigated for reliable quantitative analyses of trace elements in environmental samples. In this paper, coprecipitate separation/ID-ICP-MS for the determination of trace elements in sediment, cation exchange disk filtration/ID-ICP-MS for the determination of selenium in sediment, species-specific ID-ICP-MS using 118 Sn/labeled organotin compounds for the determination of butyltins and phenyltins, and the application of the ID-ICP-MS methods to the certification of sediment reference materials are described. (author)

  6. Accurate quantification of polycyclic aromatic hydrocarbons in dust samples using microwave-assisted solvent extraction combined with isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Itoh, Nobuyasu; Fushimi, Akihiro; Yarita, Takashi; Aoyagi, Yoshie; Numata, Masahiko

    2011-01-01

    Highlights: → We applied MAE-IDMS for accurate quantification of PAHs in dust samples. → Both partitioning and isotopic equilibria can be achieved using this technique. → MAE-IDMS can provide accurate concentrations even if extraction efficiencies were low. → Characteristics of samples strongly affected for low extraction efficiencies of PAHs. - Abstract: For accurate quantification of polycyclic aromatic hydrocarbons (PAHs) in dust samples, we investigated the use of microwave-assisted solvent extraction (MAE) combined with isotope-dilution mass spectrometry (IDMS) using deuterium-labelled PAHs (D-PAHs). Although MAE with a methanol/toluene mixture (1:3 by volume) at 160 deg. C for 40 min was best for extracting PAHs from tunnel dust among examined, the recovery yields of D-PAHs decreased with increasing molecular weight (<40% for MW ≥ 264; that of deuterium-labelled indeno[123-cd]pyrene (D-IcdP) was only 7.1%). Although the residues were extracted a second time, the observed concentrations did not change dramatically (<5%), and the recovery yields of heavier D-PAHs (i.e., MW ≥ 264) were approximately half of those of the first extract, including D-IcdP (3.4%). These results suggest that both partitioning and isotopic equilibria of PAHs and D-PAHs between sample and solvent were achieved for extractable heavier PAHs under the condition. Thus, the observed concentrations of PAHs obtained by MAE-IDMS were reasonable, even though recovery yields of D-PAHs were <50%. From the results of carbon analyses and extractable contents, lower recovery yields of D-PAHs from the tunnel dust were due to a large content of char with low extractable contents.

  7. Is the Magnetic Field in the Heliosheath Sector Region and in the Outer Heliosheath Laminar?

    Science.gov (United States)

    Opher, M.; Drake, J. F.; Swisdak, M. M.; Toth, G.

    2010-12-01

    All the current global models of the heliosphere are based on the assumption that the magnetic field in the outer heliosheath close to the heliopause is laminar. We argue that in the outer heliosheath the heliospheric magnetic field is not laminar but instead consists of nested magnetic islands. Recently, we proposed (Drake et al. 2009) that the annihilation of the ``sectored'' magnetic field within the heliosheath as it is compressed on its approach to the heliopause produces the anomalous cosmic rays (ACRs) and also energetic electrons. As a product of the annihilation of the sectored magnetic field, densly-packed magnetic islands are produced. These magnetic islands will be convected with the ambient flows as the sector boundary is carried to higher latitudes filling the outer heliosheath. We further argue that the magnetic islands will develop upstream (but still within the heliosheath) where collisionless reconnection is unfavorable -- large perturbations of the sector structure near the heliopause will cause compressions of the current sheet upstream, triggering reconnection. As a result, the magnetic field in the heliosheath sector region will be disordered well upstream of the heliopause. We present a 3D MHD simulation with unprecedent numerical resolution that captures the sector boundary. We show that due to the high pressure of the interstellar magnetic field the disordered sectored region fills a large portion of the northern part of the heliosphere with a smaller extension in the southern hemisphere. We test these ideas with observations of energetic electrons, which because of their high velocity are most sensitive to the structure of the magnetic field. We suggest that within our scenario we can explain two significant anomalies in the observations of energetic electrons in the outer heliosphere: the sudden decrease in the intensity of low energy electrons (0.02-1.5MeV) from the LECP instrument on Voyager 2 in 2008 (Decker 2010); and the dramatic

  8. Study of the extraction of the traces of Cadmium through the method of subestequiometric isotope dilution

    International Nuclear Information System (INIS)

    Garate V, Z.

    1990-01-01

    In this work, it has been used the method of subestequiometric isotope dilution for the determination of traces of cadmium and it has been compared with other conventional's methods for study its performance. The conditions of the experiment had been studied carefully in order to optimize the parameters such as pH, (8,0 - 10,1) it used the buffer NH 3 :NH 4 Cl, the time of agitation (>120 s) and the concentration of the organic reactive (dithizone). Besides, it obtains the respective curve of calibration. In this study, we can watch a line relation in all the range studied (5-40 μg of Cd). This method applied to the analysis of Cadmium in a certified sample of H-8 of the IAEA, it gives us the next value: 195 ± 5,4 ppm (LOD= 1,5 ppm, LOQ= 4,8 ppm), it is enough satisfactory in comparison with the certified middle value of 188,9±19 ppm. It demonstrates the utility of the method in the Cadmium traces analysis if it disposes of the radioisotope of this element and the appropriate detection equipment. (DEM). 34 refs., 15 tabs., 7 figs

  9. Isotope dilution/mass spectrometry of serum cholesterol with [3,4-13C]cholesterol: proposed definitive method

    International Nuclear Information System (INIS)

    Pelletier, O.; Wright, L.A.; Breckenridge, W.C.

    1987-01-01

    We describe a new gas-chromatographic/mass-spectrometric (GC/MS) isotope-dilution method for determination of serum cholesterol. The method has been fully optimized and documented to provide the high accuracy and precision expected for a Definitive Method. In the presence of [3,4- 13 C]cholesterol, cholesteryl esters in serum are hydrolyzed under optimum conditions and the entire cholesterol pool is extracted and derivatized to silyl ethers. The cholesterol derivatives are resolved from other sterols by gas-liquid chromatography on a fused silica column, and selected ions characteristic of cholesterol and the [3,4- 13 C]cholesterol are monitored with a GC/MS quandrupole system. We estimated the cholesterol content of samples by bracketing each sample with standards of comparable cholesterol concentration that also contained the [3,4- 13 C]cholesterol. The procedure was highly reproducible (CV less than 0.5%), better accuracy and precision being obtained with [3,4- 13 C]cholesterol than with heptadeuterated cholesterol. Mean values per gram of dry serum for one serum pool assayed by this method and that of the National Bureau of Standards differed by 0.5%. We conclude that the method satisfies the criteria for a Definitive Method

  10. Determination of rare earth elements in environmental matrices by sector-field inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Riondato, J; Vanhaecke, F; Moens, L; Dams, R

    2001-07-01

    In the framework of an international certification campaign, sector-field inductively coupled plasma mass spectrometry (sector-field ICP-MS) was used for the accurate determination of the rare earth elements in five candidate reference materials: aquatic plant, calcareous soil, mussel tissue, river sediment, and tuna muscle. All samples were taken into solution by use of microwave-assisted or mixed microwave-assisted / open beaker acid digestion. Subsequently, the samples were appropriately diluted and subjected to ICP-MS analysis. Except for Sc, all the elements involved were determined at low mass resolution (R = 300). For Sc, application of a higher resolution setting (R = 3,000) was required to separate the analyte signal from those of several molecular ions which gave rise to spectral overlap at low mass resolution. Some of the heavier REE can also suffer from spectral overlap attributed to the occurrence of oxide ions (MO+) of the lighter REE and Ba. This spectral overlap could be successfully overcome by mathematical correction. Matrix effects were overcome by use of two carefully selected internal standards, such that external calibration could be used. On each occasion, a geological reference material was analyzed as a quality-control sample and the reliability of all results obtained was additionally checked by means of chondrite normalization. For tuna muscle the content of all REE was below the limit of detection. For calcareous soil and river sediment, low to sub microg g(-1) values were observed, whereas the REE content of aquatic plant and mussel tissue was considerably lower (low to sub ng g(-1)). Overall, the results obtained were in excellent agreement with the average values, calculated on the basis of all "accepted" values, obtained in different laboratories using different techniques.

  11. Isotope analysis of lithium by thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Kakazu, M.H.; Sarkis, J.E.S.

    1991-04-01

    An analytical mass spectrometric method for the isotope analysis of lithium has been studied. The analysis were carried out by using a single focusing thermoionic mass spectrometer Varian Mat TH5 with 90 sup(0) magnetic sector field and 21.4 cm deflection radius, equipped with a dual Re-filament thermal ionization ion source. The effect of different lithium chemical forms, such as, carbonate, chloride, nitrate and sulfate upon the isotopic ratios sup(6)Li/ sup(7)Li has been studied. Isotopic fractionation of lithium was studied in terms of the time of analysis. The results obtained with lithium carbonate yielded a precision of ±0.1% and an accuracy of ± 0.6%, whereas with other chemical forms yielded precisions of ±0.5% and accuracies of ±2%. A fractionation correction factor, K=1.005, was obtained for different samples of lithium carbonate isotopic standard CBNM IRM 016, which has been considered constant. (author)

  12. Estimation of the dilution field near a marine outfall by using effluent turbidity as an environmental tracer and comparison with dye tracer data.

    Science.gov (United States)

    Pecly, José Otavio Goulart

    2018-01-01

    The alternative use of effluent turbidity to determine the dilution field of a domestic marine outfall located off the city of Rio de Janeiro was evaluated through field work comprising fluorescent dye tracer injection and tracking with simultaneous monitoring of sea water turbidity. A preliminary laboratory assessment was carried out with a sample of the outfall effluent whose turbidity was measured by the nephelometric method before and during a serial dilution process. During the field campaign, the dye tracer was monitored with field fluorometers and the turbidity was observed with an optical backscattering sensor interfaced to an OEM data acquisition system. About 4,000 samples were gathered, covering an area of 3 km × 3 km near the outfall diffusers. At the far field - where a drift towards the coastline was observed - the effluent plume was adequately labeled by the dye tracer. The turbidity plume was biased due to the high and variable background turbidity of sea water. After processing the turbidity dataset with a baseline detrending method, the plume presented high correlation with the dye tracer plume drawn on the near dilution field. However, dye tracer remains more robust than effluent turbidity.

  13. Dilution Confusion: Conventions for Defining a Dilution

    Science.gov (United States)

    Fishel, Laurence A.

    2010-01-01

    Two conventions for preparing dilutions are used in clinical laboratories. The first convention defines an "a:b" dilution as "a" volumes of solution A plus "b" volumes of solution B. The second convention defines an "a:b" dilution as "a" volumes of solution A diluted into a final volume of "b". Use of the incorrect dilution convention could affect…

  14. Monitoring the degradation and solubilisation of butyltin compounds during in vitro gastrointestinal digestion using ''triple spike'' isotope dilution GC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Gonzalez, Pablo; Encinar, Jorge Ruiz; Alonso, J. Ignacio Garcia; Sanz-Medel, Alfredo [Department of Physical and Analytical Chemistry, Oviedo (Spain). Faculty of Chemistry

    2005-01-01

    An in vitro gastrointestinal digestion approach in combination with species-specific isotope dilution analysis has been employed for the first time to study the transformation reactions as well as the solubilisation of butyltin species throughout a simulated human digestion. Different sample preparation procedures were assayed in order to avoid problems derived from lack of isotope equilibration between the endogenous and the isotopically-enriched added species. A ''triple spike'' approach, which can be used to calculate the corrected concentrations of mono-, di-, and tributyltin (MBT, DBT and TBT, respectively), as well as six interconversions, was employed throughout this work. In order to calculate and compare the species degradation factors, a triple spike solution containing each butyltin species enriched in a different isotope was added to the simulated gastric and intestinal fluids before the digestion procedures in the presence and in the absence of a solid biological matrix (commercial mussel tissue). Additionally, by analysing the soluble and insoluble fractions resulting from the simulated digestion of a commercial mussel tissue (gastric and gastric plus intestinal digestion), total mass balances for each butyltin compound could be derived. For this purpose, the isotopically-enriched species were added after the enzymatic digestions in order to avoid problems derived from lack of isotope equilibration. The mass balances provided information not only about the solubilisation but also about the degradation of the butyltin species during the digestion procedures. Good agreement between the degradation factors calculated under all experiments performed in this work and between those reported in previous works were obtained. The most serious degradation observed was that of DBT to produce MBT, whereas slight degradations of TBT and MBT were detected. Moreover, a worrying 61% of the original total butyltin content present in a commercial

  15. Mutual complementation between water chemistry and isotope techniques

    International Nuclear Information System (INIS)

    Matthess, G.

    1976-01-01

    In the water chemistry and isotope methods which applied together enable more extensive statements to be made than each on its own, the following regions of cooperation are brought out: 1) Isotopes as conservative indicators a) microbial decomposition of organic substances in the anaerobic and aerobic region; b) precipitation and coprecipitation; c) mechanical filtration, adsorption and coprecipitation; d) gas exchange; e) dilution by infiltration; 2) geochemical observations as additional basis for isotope investigations; 3) the investigation of the water content substances as additional help to isotope hydrology. (HK/LH) [de

  16. Accurate isotope ratio mass spectrometry. Some problems and possibilities

    International Nuclear Information System (INIS)

    Bievre, P. de

    1978-01-01

    The review includes reference to 190 papers, mainly published during the last 10 years. It covers the following: important factors in accurate isotope ratio measurements (precision and accuracy of isotope ratio measurements -exemplified by determinations of 235 U/ 238 U and of other elements including 239 Pu/ 240 Pu; isotope fractionation -exemplified by curves for Rb, U); applications (atomic weights); the Oklo natural nuclear reactor (discovered by UF 6 mass spectrometry at Pierrelatte); nuclear and other constants; isotope ratio measurements in nuclear geology and isotope cosmology - accurate age determination; isotope ratio measurements on very small samples - archaeometry; isotope dilution; miscellaneous applications; and future prospects. (U.K.)

  17. Isotope dilution mass spectrometry as the primary method of measurement for the amount of matter. Application to cadmium determination in biological materials and comparison with instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Ferrada, Carlos

    2001-01-01

    A primary method of measurement as defined by the Consultative Committee on the Quantity of Matter (Comite Consultatif pour la Quantite de Matiere, CCQM) of the International Bureau of Weights and Measurements (Bureau International des Poids et Mesures, BIPM), is one whose measurement process is perfectly known, has valid theoretical foundations and is fully described and answers to an equation that relates what is measured with what is intended to be measured without any significant empirical correction factors. It is also a method that has insignificant systematic errors, where only magnitudes from the International System of Units (SI) are used and where, preferably, the uncertainties are small ones. They are, therefore, procedures that do not need instrumental calibration. The absolute methods of measurement allow a chain of traceability to be formed between the result obtained and the magnitude of the SI assigned to what is measured. So the results are said to be traceable to the SI. One of the methods that meets these requirements and is recognized as the primary method by the CCQM is Isotope Dilution Mass Spectrometry (IDMS). Through a project of Technical Cooperation with the International Atomic Energy Agency in the area of Chemical Metrology, the CCHEN obtained training in CIEMAT, Spain, in IDMS and its applications to the analysis of biological samples. This work describes the first experience carried out entirely in Chilean laboratories, applying IDMS to the determination of cadmium in the biological reference materials Oyster Tissue 15566-A from the NIST, United States, Dogfish Liver, DOLT-2 from the NRC-CNRC, Canada and Poplar Leaves GBW07604 from the NRCC, China. The samples were traced with an isotope enriched spike 111 Cd and then shaken to obtain the isotopic exchange. Once dissolved, the isotopic relationship 111 Cd/ 114 Cd was determined in the samples using mass spectrometry with plasma source. These results were compared with those obtained

  18. Neutron scattering study of dilute supercritical solutions

    International Nuclear Information System (INIS)

    Cochran, H.D.; Wignall, G.D.; Shah, V.M.; Londono, J.D.; Bienkowski, P.R.

    1994-01-01

    Dilute solutions in supercritical solvents exhibit interesting microstructures that are related to their dramatic macroscopic behavior. In typical attractive solutions, solutes are believed to be surrounded by clusters of solvent molecules, and solute molecules are believed to congregate in the vicinity of one another. Repulsive solutions, on the other hand, exhibit a local region of reduced solvent density around the solute with solute-solute congregation. Such microstructures influence solubility, partial molar volume, reaction kinetics, and many other properties. We have undertaken to observe these interesting microstructures directly by neutron scattering experiments on dilute noble gas systems including Ar. The three partial structure factors for such systems and the corresponding pair correlation functions can be determined by using the isotope substitution technique. The systems studied are uniquely suited for our objectives because of the large coherent neutron scattering length of the isotope 36 Ar and because of the accurate potential energy functions that are available for use in molecular simulations and theoretical calculations to be compared with the scattering results. We will describe our experiment, the unique apparatus we have built for it, and the neutron scattering results from our initial allocations of beam time. We will also describe planned scattering experiments to follow those with noble gases, including study of long-chain molecules in supercritical solvents. Such studies will involve hydrocarbon mixtures with and without deuteration to provide contrast

  19. Determination of steroid hormones in a human-serum reference material by isotope dilution--mass spectrometry: A candidate definitive method for cortisol

    International Nuclear Information System (INIS)

    Patterson, D.G.; Patterson, M.B.; Culbreth, P.H.; Fast, D.M.; Holler, J.S.; Sampson, E.J.; Bayse, D.D.

    1984-01-01

    We report a method, based on isotope dilution--mass spectrometry, for determining cortisol in a pooled specimen of human serum. Isotopically labeled cortisol is added to 5.0 mL of serum so that the molar concentrations of labeled cortisol and unlabeled cortisol are approximately equal. The specimen and two calibration standards are extracted with dichloromethane, and the extracted cortisol is converted to the methoxime-trimethylsilyl ether derivative. Samples and standards are analyzed by gas chromatography--mass spectrometry by monitoring the peak areas for m/z 605 and 608. The cortisol concentration is calculated by linear interpolation between the two bracketing standards. Variances of data collected during six weeks showed that the overall coefficient of variation (CV) was 0.69% (n . 32); the within-vial CV, 0.63%; the among-vial CV, 0.22%; and the among-day CV, 0.15% (means . 3.973 nmol/vial). Method specificity was demonstrated by liquid chromatographic as well as C 8 mini-column cleanup of samples before derivation, by alternative ion monitoring at m/z 636 and 639, and by negative-ion chemical ionization at m/z 459 and 462. Derivatives of all observed degradation products of cortisol under basic, neutral, and acidic conditions did not interfere

  20. Substoichiometric isotope dilution analysis of arsenic in biological and environmental standard reference materials by solvent extraction using toluene-3,4-dithiol in benzene

    International Nuclear Information System (INIS)

    Chutke, N.L.; Ambulkar, Ms.M.N.; Weginwar, R.G.; Garg, A.N.

    1994-01-01

    A radiochemical solvent extraction procedure has been developed for the determination of As(III) using 76 As tracer. It is based on the complexation of As(III) with toluene-3,4-dithiol (TDT) at pH 2 and subsequent extraction in benzene. The effect of various parameters such as pH, time of equilibration, nature of solvent, quantitative character and interferences have been studied. The method has been further developed into substoichiometric isotope dilution analysis for the determination of As at < 1μg level and employed for the analysis of several environmental and biological standard Reference Materials from NIST (USA), IAEA (Vienna) and NIES (Japan). (author) 39 refs.; 4 figs.; 4 tabs

  1. Determination of endogenous manganese excretion in broiler chicks by an isotope-dilution method

    International Nuclear Information System (INIS)

    Weigand, E.; Kirchgessner, M.; Kilic, A.

    1988-01-01

    A tracer study with broiler chicks was conducted to determine endogenous Mn excretion in response to graded levels of dietary Mn supply by the isotope-dilution method. Starting with 46 day-old chicks, low-Mn diets were fed for 12 days before 8 chicks were slaughtered for assessing the intial Mn status and 38 chicks each were given an intramuscular injection of 555 kBq 54 Mn. Four groups of six birds each were fed, one bird per cage, diets containing 2.8, 9.1, 25.8, and 59.7 ppm Mn for 16 days before slaughter and carcass analyses. Two groups of 7 birds were fed the diets with 9.1 and 25.8 ppm Mn for 8 days. Mn supply significantly affected 54 Mn excretion activity of distribution among various body organs, especially the liver. The specific activity of Mn in excreta and in whole-body declined exponentially with time and differed between groups. Endogenous Mn in excreta was estimated on the basis that the specific activity of excreta Mn from day 9 to 12 and day 13 to 16 was reflected, on the average, by that of liver Mn on day 10 and 14, respectively. It averaged in the order of increasing Mn supply 12.5 vs. 12.0; 7.7 vs. 8.5; 3.9 vs. 4.3, and 2.0 vs. 2.3% of total excreta Mn. Total Mn excretion from day 9 to 16 averaged 88.9, 95.0, 97.9. and 98.9% of Mn intake. (author)

  2. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  3. Phosphorus availability to ryegrass from urban sewage sludges assessed by isotopic labeling and dilution technique, effect of irradiation

    International Nuclear Information System (INIS)

    El-Motaium, R.A.; Morel, C.

    2007-01-01

    Urban sewage sludge are widely used as alternative P input because of their high P content. Irradiation of sewage sludge is developed in Egypt to make safe spreading of sludge on agricultural fields. Five sludges were sampled from representative urban wastewater treatment plants located in Cairo, Egypt. Sub samples were irradiated using gamma radiation at 6 KGy dose. A pot experiment was conducted under plastic greenhouse using sandy P-deficient soil. The soil was homogeneously labelled with a radioactive solution of carrier-free 32 PO 4 (about 3 MBq kg / soil) to determine the contribution of the different sources of P in plant nutrition. Sludges were applied at 50 mg P/ kg soil. In addition, a control treatment was also carried out to analyze sludge P availability in comparison to a water soluble mineral fertilizer, i.e. 50 mg P/kg soil was applied as commercial monocalcium phosphate (SSP). A reference treatment was included without any P application but the radioactive solution was added. One gram of ryegrass seeds (Lolium multiflorium) was sown in each pot. The aerial parts of the ryegrass were harvested four times, every 3 weeks. Analysis of all harvests included 32 P and total P content was used to determine the respective contribution of soil and sludge to plant P nutrition and the plant available P (L value) using the isotopic dilution principle. The ratio of radioactive P to non-radioactive P, i.e. isotopic composition, was calculated. The total P content in the different urban sewage sludge was ranged from 6.2 to 13.8 g P/ kg and affected by irradiation. Because the soil was extremely P deficient (L value=0.3 mg P/ kg soil), P derived from seeds represented 99% of the P taken up when no P was applied and 87% when applying 50 mg P-SSP/ kg. After correcting the contribution of ryegrass seeds, sludge P contributed by 98% to plant nutrition and 7.2% of the applied P was recovered. The sludge type and irradiation factors did not significantly affect sludge P

  4. Immunocapture isotope dilution mass spectrometry in response to a pandemic influenza threat.

    Science.gov (United States)

    Pierce, Carrie L; Williams, Tracie L; Santana, Wanda I; Levine, Marnie; Chen, Li-Mei; Cooper, Hans C; Solano, Maria I; Woolfitt, Adrian R; Marasco, Wayne A; Fang, He; Donis, Ruben O; Barr, John R

    2017-09-05

    As a result of recent advances in mass spectrometry-based protein quantitation methods, these techniques are now poised to play a critical role in rapid formulation of pandemic influenza vaccines. Analytical techniques that have been developed and validated on seasonal influenza strains can be used to increase the quality and decrease the time required to deliver protective pandemic vaccines to the global population. The emergence of a potentially pandemic avian influenza A (H7N9) virus in March of 2013, prompted the US public health authorities and the vaccine industry to initiate production of a pre-pandemic vaccine for preparedness purposes. To this end, we evaluated the feasibility of using immunocapture isotope dilution mass spectrometry (IC-IDMS) to evaluate the suitability of the underlying monoclonal and polyclonal antibodies (mAbs and pAbs) for their capacity to isolate the H7 hemagglutinin (HA) in this new vaccine for quantification by IDMS. A broad range of H7 capture efficiencies was observed among mAbs tested by IC-IDMS with FR-545, 46/6, and G3 A533 exhibiting the highest cross-reactivity capabilities to H7 of A/Shanghai/2/2013. MAb FR-545 was selected for continued assessment, evaluated by IC-IDMS for mAb reactivity against H7 in the H7N9 candidate vaccine virus and compared with/to reactivity to the reference polyclonal antiserum in allantoic fluid, purified whole virus, lyophilized whole virus and final detergent-split monovalent vaccine preparations for vaccine development. IC-IDMS assessment of FR-545 alongside IC-IDMS using the reference polyclonal antiserum to A/Shanghai/2/2013 and with the regulatory SRID method showed strong correlation and mAb IC-IDMS could have played an important role in the event a potential surrogate potency test was required to be rapidly implemented. Published by Elsevier Ltd.

  5. Harmonisation efforts in the field of accounting of public sector

    Directory of Open Access Journals (Sweden)

    Milena Otavová

    2011-01-01

    Full Text Available Increasing requirements for financial reporting of public sector led to a need to create a system that would provide relevant and reliable information for management of accounting entities of public sector and also to increase the quality of accounting and financial statements of public institutions. The International Public Sector Accounting Standards Board (IPSASB is therefore creating high-quality financial reporting standards for public sector (IPSAS. Paper points out the ongoing reform of accounting in the field of public finances in the Czech Republic, where there are substantial changes in accounting rules and it also introduces new accounting methods. Regarding the fact that accounting of public sector is nowadays accounting system perhaps with the greatest potential of development, paper highlights the differences in financial reporting in accordance with Czech legislation and IPSAS system. It tries to catch the essential differences that arise from the financial legislation, the accounting basis and also from the content of financial statements. The paper also indicates the difference between Czech Accounting Standards for selected accounting entities that maintain accounts in accordance with Decree No. 410/2009 Coll. and International Public Sector Accounting Standards (IPSAS. There is also recommended approach to the creation of national standards with regard to international harmonization.

  6. Genetic variability in dinitrogen fixation between cowpea [Vigna unguiculata (L.) Walp] cultivars determined using the nitrogen-15 isotope dilution technique

    International Nuclear Information System (INIS)

    Ndiaye, M.A.F.; Spencer, M.M.; Gueye, M.

    2000-01-01

    N fixed in 16 cultivars of cowpea [Vigna unguiculata (L.) Walp] inoculated with effective Bradyrhizobium strains collected from the West African MIRCEN culture collection was measured by 15N isotope dilution technique. In all plant parts, significant differences in the percentage of N derived from the atmosphere (%Ndfa) and the amount of Ndfa occurred between the cultivars. Ndoute variety exhibited the highest %Ndfa (74.33% in shoots; 60.90% in roots) and accumulated more fixed N (960 mg N plant–1 and 38 mg N plant–1 in shoots and roots, respectively). Therefore this cultivar should be selected as the highest N-fixing cowpea cultivar. It also should be used in a breeding programme to contribute to the development of cultivars that could stimulate an intensive use of cowpea in many different cropping systems in Africa with a view to maintaining soil fertility. (Authors)

  7. Stable isotope dilution HILIC-MS/MS method for accurate quantification of glutamic acid, glutamine, pyroglutamic acid, GABA and theanine in mouse brain tissues.

    Science.gov (United States)

    Inoue, Koichi; Miyazaki, Yasuto; Unno, Keiko; Min, Jun Zhe; Todoroki, Kenichiro; Toyo'oka, Toshimasa

    2016-01-01

    In this study, we developed the stable isotope dilution hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS) technique for the accurate, reasonable and simultaneous quantification of glutamic acid (Glu), glutamine (Gln), pyroglutamic acid (pGlu), γ-aminobutyric acid (GABA) and theanine in mouse brain tissues. The quantification of these analytes was accomplished using stable isotope internal standards and the HILIC separating mode to fully correct the intramolecular cyclization during the electrospray ionization. It was shown that linear calibrations were available with high coefficients of correlation (r(2)  > 0.999, range from 10 pmol/mL to 50 mol/mL). For application of the theanine intake, the determination of Glu, Gln, pGlu, GABA and theanine in the hippocampus and central cortex tissues was performed based on our developed method. In the region of the hippocampus, the concentration levels of Glu and pGlu were significantly reduced during reality-based theanine intake. Conversely, the concentration level of GABA increased. This result showed that transited theanine has an effect on the metabolic balance of Glu analogs in the hippocampus. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Trace analysis of U, Th and other heavy metals in high purity aluminium with isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Beer, B.; Heumann, K.G.

    1992-01-01

    A method for the determination of very low concentrations of U, Th, Fe, Zn, Tl, Cd, Cu and Ag in high purity aluminium with isotope dilution mass spectrometry (IDMS) is developed using a compact and cost-efficient thermal ionization quadrupole mass spectrometer. The detection limits obtained are (in ng/g):U=0.018, Th=0.06, Fe=82, Zn=86, Tl=0.2, Cd=4, Cu=1, Ag=2.6. By this method it is possible to determine the α-emitters U and Th in aluminium down to the sub-ng/g level with good precision of 0.4-10% and 0.5-5%, respectively. The results should also be accurate because IDMS is a reliable analytical method. The dissolution of aluminium is carried out by aqua regia followed by the trace/matrix separation and the isolation of the trace elements by anion exchange chromatography (U, Th, Zn, Tl, Cd), electrodeposition (Cu, Ag) and extraction (Fe). Different aluminium samples are analysed by IDMS and the results are compared with those of other methods. (orig.)

  9. The effect of different levels of fertilizer on nitrogen nutrient of pasture using 15N-isotope dilution method

    International Nuclear Information System (INIS)

    Wei Dongpu; Bai Lingyu; Hua Luo; Yao Yunyin

    2000-01-01

    A pot experiment was carried out to study the effect of different levels of fertilizer on N% of ryegrass in monoculture or mixed culture with white clover and symbiotic dinitrogen fixation of white clover by using 15 N-isotope dilution method. It showed that (1) N% of ryegrass in monoculture or mixed culture was the highest at 67 days after fertilizing (DAF) and decreased with time; (2) N% of white clover was the greatest at 67 DAF, slightly decreased at 92 DAF, and then increased at 137 DAF, related to the increasing of nitrogen fixation by white clover; (3) At 164 kg 15 NH 4 SO 4 /hm 2 , N% of ryegrass in mixed culture at different cutting time was greater than that in monoculture. It obviously occurred that fixed nitrogen was transferred from white clover to ryegrass in mixed; (4) During the whole growth period, the main nitrogen resource of white clover was symbiotic dinitrogen fixation and that of ryegrass was soil nitrogen; (5) Effect of different levels of applied N on N% of ryegrass and white clover was significant

  10. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  11. Certification of the Cu and Cd amount contents in artificial food digest using isotope dilution inductively coupled plasma mass spectrometry for Pilot Study 13 of the Comite Consultatif pour la Quantite de Matiere

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, C.R.; Petrov, I.

    2003-01-01

    The Comite Consultatif pour la Quantite de Matiere (CCQM) launched the Pilot Study 13, an interlaboratory comparison between the metrological organizations worldwide on the determination of Ca, Cu and Cd in artificial food digests. These samples (available in 7% HNO 3 and with a salinity evaluated around 370 mg kg -1 , including approx. 30 mg Na kg -1 ) were prepared by gravimetrical mixing, and thus reference values traceable to the Kg for the three elements were available eventually. This paper describes the contribution of IRMM for the certification of the Cu and the Cd amount contents. The analytical protocol developed was based on isotope dilution associated to inductively coupled plasma mass spectrometry (ID-ICP-MS). The Cu measurements required 125-fold dilution of the initial sample solution. An interference of 23 Na 40 Ar + on 63 Cu + was identified but, since the ratio between both species was over 1000, it was successfully overcome by the calculation of a correction factor for its effect on the Cu amount content directly. Dilution of the sample was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This is rarely shown. As similar results could be obtained either way after the necessary corrections, the direct measurements approach associated to a correction for mass discrimination effects using the CCQM-P13 sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. SI traceable values were obtained for Cu and Cd with less than 1 and 1.5% combined uncertainty, respectively (6 995±55 (k=2) nmol kg -1 and 45.53±0.64 (k=2) nmol kg -1 ). The excellent agreement between these results and the reference values (less than 0.6 and 0.08% difference) further validated the analytical protocols developed

  12. Determination of Cd, Hg, Pb and Se in sediments slurries by isotopic dilution calibration ICP-MS after chemical vapor generation using an on-line system or retention in an electrothermal vaporizer treated with iridium

    International Nuclear Information System (INIS)

    Vieira, Mariana Antunes; Ribeiro, Anderson Schwingel; Dias, Lucia Felicidade; Curtius, Adilson Jose

    2005-01-01

    A method for the determination of Cd, Hg, Pb and Se in sediments reference materials by slurry sampling chemical vapor generation (CVG) using isotopic dilution (ID) calibration and detection by inductively coupled plasma mass spectrometry (ICP-MS) is proposed. Two different systems were used for the investigation: an on-line flow injection system (FI-CVG-ICP-MS) and an off-line system with in situ trapping electrothermal vaporization (CVG-ETV-ICP-MS). About 100 mg of the reference material, ground to a particle size ≤50 μm, was mixed with acid solutions (aqua regia, HF and HCl) in an ultrasonic bath. The enriched isotopes 111 Cd, 198 Hg, 206 Pb and 77 Se were then added to the slurry in an adequate amount in order to produce an altered isotopic ratio close to 1. For the on-line system, a standing time for the slurry of 12 h before measurement was required, while for the batch system, no standing time is needed to obtain accurate results. The conditions for the formation of the analyte vapor were optimized for the evaluated systems. The following altered isotope ratios were measured: 111 Cd/ 114 Cd, 198 Hg/ 199 Hg, 206 Pb/ 208 Pb e 77 Se/ 82 Se. The obtained detection limits in the on-line system, in μg g -1 , were: Cd: 0.15; Hg: 0.09; Pb: 6.0 and Se: 0.03. Similar detection limits were obtained with the system that uses the ETV: 0.21 for Hg, 6.0 for Pb and 0.06 μg g -1 for Se. No signal for Cd was obtained in this system. One estuarine, two marine and two river certified sediments were analyzed to check the accuracy. The obtained values by both systems were generally in agreement with the certified concentrations, according to the t-test for a confidence level of 95%, demonstrating that isotope equilibration was attained in the slurries submitted to a chemical vapor generation procedure and detection by ICP-MS. The relative standard deviations were lower than 10%, adequate for slurry analysis. The almost quantitative analytes extractions to the aqueous phase

  13. Initial magnetic susceptibility of the diluted magnetopolymer elastic composites

    International Nuclear Information System (INIS)

    Borin, D.Yu.; Odenbach, S.

    2017-01-01

    In this work diluted magnetopolymer elastic composites based on magnetic microparticles are experimentally studied. Considered samples have varied concentration of the magnetic powder and different structural anisotropy. Experimental data on magnetic properties are accomplished by microstructural observations performed using X-Ray tomography. Influence of the particles amount and structuring effects on the initial magnetic susceptibility of the composites as well as the applicability of the Maxwell-Garnett approximation, which is widely used in considerations of magnetopolymer elastic composites, are evaluated. It is demonstrated that the approximation works well for diluted samples containing randomly distributed magnetic particles and for the diluted samples with chain-like structures oriented perpendicular to an externally applied field, while it fails to predict the susceptibility of the samples with structures oriented parallel to the field. Moreover, it is shown, that variation of the chains morphology does not significantly change the composite initial magnetic susceptibility. - Highlights: • The Maxwell-Garnet prediction works well for the diluted isotropic composites. • The Maxwell-Garnet prediction can be used for composites with structures oriented perpendicular to an applied field. • Chains oriented parallel to an applied field significantly increase the composite initial magnetic susceptibility. • The number and thickness of chains is not of the highest importance for the diluted composites. • The crucial reason of the observed effect is expected to be the demagnetisation factor of the chains.

  14. Efficient mass calibration of magnetic sector mass spectrometers

    International Nuclear Information System (INIS)

    Roddick, J.C.

    1996-01-01

    Magnetic sector mass spectrometers used for automatic acquisition of precise isotopic data are usually controlled with Hall probes and software that uses polynomial equations to define and calibrate the mass-field relations required for mass focusing. This procedure requires a number of reference masses and careful tuning to define and maintain an accurate mass calibration. A simplified equation is presented and applied to several different magnetically controlled mass spectrometers. The equation accounts for nonlinearity in typical Hall probe controlled mass-field relations, reduces calibration to a linear fitting procedure, and is sufficiently accurate to permit calibration over a mass range of 2 to 200 amu with only two defining masses. Procedures developed can quickly correct for normal drift in calibrations and compensate for drift during isotopic analysis over a limited mass range such as a single element. The equation is: Field A·Mass 1/2 + B·(Mass) p where A, B, and p are constants. The power value p has a characteristic value for a Hall probe/controller and is insensitive to changing conditions, thus reducing calibration to a linear regression to determine optimum A and B. (author). 1 ref., 1 tab., 6 figs

  15. Combination of pentafluorophenylhydrazine derivatization and isotope dilution LC-MS/MS techniques for the quantification of apurinic/apyrimidinic sites in cellular DNA.

    Science.gov (United States)

    Li, Jie; Leung, Elvis M K; Choi, Martin M F; Chan, Wan

    2013-05-01

    Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/10(9) nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.

  16. A non-destructive method of determination of biomass of mango (Mangifera indica L.) and guava trees using principle of isotope dilution

    International Nuclear Information System (INIS)

    Kotur, S.C.; Keshava Murthy, S.V.

    2004-01-01

    Biomass of 4-year old trees 'Alphonso' mango was estimated by injecting carrier- free 32 P into the trunk followed by radioassay of the isotope after a complete dilution of 32 P in the tree (3 months after injection). The isotopically calculated plant volume (56.903 - 68.981 m 3 x10 3 ) and biomass (31.70 - 36.23 gx 10 -3 ) showed good agreement but generally overestimated both by about 19 per cent compared to the actual values determined physically (43.720 - 60.693 m 3 x10 3 and 22.88 - 34.78 gx 10 -3 , respectively). Application of the technique in a set of four 15-year old mango trees yielded volume estimates of 170.749 - 175.835 m 3 x10 3 (mean 173.512 ± 1.12 per cent) and biomass estimates of 73.0 - 87.4 gx10 -3 (mean = 80.32 ± 6.79 per cent). In another set of four 12-year old guava trees the corresponding values were 40.165 to 44.014 m 3 x10 3 (mean = 41.743 ± 3.42 per cent) and 22.252 gxl0 -3 (mean = 23.210 ± 2.95 per cent) respectively. The technique is of promise in fertilizer use efficiency and nutrient dynamics studies in tree crops. (author)

  17. Electromagnetic separator for light and middle isotope elements; Separateur electromagnetique pour les isotopes d'elements legers et moyens

    Energy Technology Data Exchange (ETDEWEB)

    Bernas, R [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1952-07-01

    We describe a separator of isotope with a 60 deg magnetic sector that permits, thanks to a process of neutralization of the space charge, to use efficiently intense ion beams. The ion source for solid is essentially constituted by a discharge of hot cathode in a magnetic field and provides an ion beam focused of more than 10 mA. The result of the first separations (Zn, Sb, Hg) indicates that the isotopes of various elements can be obtained in quantities varying from 10 to 100 mg/24 hours. (author) [French] 0n decrit un separateur d'isotope a secteur magnetique de 60 deg qui permet, grace a un procede de neutralisation de la charge d'espace, d'utiliser efficacement des faisceaux d'ions intenses. La source d'ions pour solide est essentiellement constituee par une decharge a cathode chaude dans un champ magnetique et fournit un faisceau d'ion focalises de plus de 10 mA. Le resultat des premieres separations (Zn, Sb, Hg) indique que les isotopes de divers elements peuvent etre obtenus en quantites variant de 10 a 100 mg/24 heures. (auteur)

  18. Critical behavior of mean-field spin glasses on a dilute random graph

    Energy Technology Data Exchange (ETDEWEB)

    De Sanctis, Luca [Dipartimento di Matematica e di Psicologia, Universita di Bologna, P.zza di Porta San Donato 5, 40126 Bologna (Italy); Barra, Adriano; Folli, Viola [Dipartimento di Fisica, Universita La Sapienza, P.le Aldo Moro 5, 00185 Roma (Italy)], E-mail: desanctis@dm.unibo.it, E-mail: adriano.barra@roma1.infn.it, E-mail: viola.folli@roma1.infn.it

    2008-05-30

    We provide a rigorous strategy to find the critical exponents of the overlaps for dilute spin glasses, in the absence of an external field. Such a strategy is based on the expansion of a suitably perturbed average of the overlaps, which is used in the formulation of the free energy as the difference between a cavity part and the derivative of the free energy itself, considered as a function of the connectivity of the model. We assume the validity of certain reasonable approximations, equivalent to assuming a second-order transition, e.g. that higher powers of overlap monomials are of smaller magnitude near the critical point, of which we do not provide a rigorous proof.

  19. Critical behavior of mean-field spin glasses on a dilute random graph

    International Nuclear Information System (INIS)

    De Sanctis, Luca; Barra, Adriano; Folli, Viola

    2008-01-01

    We provide a rigorous strategy to find the critical exponents of the overlaps for dilute spin glasses, in the absence of an external field. Such a strategy is based on the expansion of a suitably perturbed average of the overlaps, which is used in the formulation of the free energy as the difference between a cavity part and the derivative of the free energy itself, considered as a function of the connectivity of the model. We assume the validity of certain reasonable approximations, equivalent to assuming a second-order transition, e.g. that higher powers of overlap monomials are of smaller magnitude near the critical point, of which we do not provide a rigorous proof

  20. Recent development in isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Platzner, I.

    1992-01-01

    Within the limited of this review the following topics will be briefly discussed: a) Accuracy, precision, internal relative standard deviation (RISD) and external relative standard deviation (RESD) of isotope ratio measurements. With advanced instrumentation and use of standard reference materials, high accuracy and RESD = 0.002% (or better) may be achieved; b) The advantages of modern automatic isotope ratio mass spectrometer are briefly described. Computer controlled operation and data acquisition, and multiple ion collection are the recent important improvement; c) The isotopic fractionation during the course of isotope ratio measurement is considered as a major source of errors in thermal ionization of metallic elements. The phenomenon in strontium, neodymium, uranium, lead and calcium and methods to correct the measured data are discussed; d) Applications of isotope ratio mass spectrometry in atomic weight determinations, the isotope dilution technique, isotope geology, and isotope effects in biological systems are described together with specific applications in various research and technology area. (author)

  1. Determination of symbiotic nitrogen fixation by labelling the soil atmosphere with sup(15)N sub(2) at low isotope enrichment

    International Nuclear Information System (INIS)

    Trivelin, P.C.O.

    1982-01-01

    A direct method to determine the total symbiotic nitrogen fixation during the leguminous plants cycles has been, developed, by labelling the soil atmosphere with sup(15)N sub(2) at low isotope enrichment, of about 1 atom % excess. The soil explored by the root system of leguminous plants was confined by means of a chamber in the field and by sealed pots in greenhouse experiments in order to maintain the soil air labelled with sup(15)N sub(2). The average sup(15)N concentration in the soil atmosphere, necessary to calculate dinitrogen fixation, was obtained by integration of the exponential functions of isotope dilution. Those functions were obtained by periodic sampling and analysis of the N sub(2) in the soil atmosphere. The field experiment with labelled atmosphere was carried out from the 22 sup(nd) to the 31 sup(st) day of the bean crop cycle and 5.5 mg N/plant (24% of total plant N) was derived from fixation. In pot experiments, under greenhouse conditions, integrated determination of fixation was made in Phaseolus beans (from the 19 sup(th) to the 67 sup(th) day from planting) and in soybeans (from the 24 sup(th) to the 70 sup(th) day from planting). The soil atmosphere was labelled with sup(15)N sub(2) in both cases. Average fixation obtained for Phaseolus beans was 80 mg N/plant (65% of total plant N) and for soybeans 265 mg N/plant (71% of total plant N). Evaluation of the basic concept of the isotope dilution method to determine nitrogen fixation in pots experiments, as proposed by Fried and Middelboe (1977) has also been made in the present paper. Simultaneous determinations of fixation in soybeans, using the isotope dilution method of Fried and Middelboe, natural variation of the sup(15)N/ sup(14)N ratios, and total-N differences, indicated the same results for pot experiments, harvested at the end of the plant cycle. (author)

  2. Random-field effects on the order in the diluted weakly anisotropic antiferromagnet K2NixZn1-xF4

    DEFF Research Database (Denmark)

    Dikken, B. J.; Arts, A. F. M.; Wijn, H. W. de

    1984-01-01

    With the use of neutron diffraction, the effects of random fields are studied in the diluted quadratic-layer antiferromagnet K2NixZn1-xF4 for x=0.96, 0.85, and 0.75. Upon cooling in external fields as small as H∼0.1 T, the systems quench into a nonequilibrium domain state characterized...

  3. Sulphur isotope variations in the atmosphere

    International Nuclear Information System (INIS)

    Newman, L.; Krouse, H.R.; Grinenko, V.A.

    1991-01-01

    The measurement of the isotope ratios of sulphur and oxygen can in principal be used to assess sulphur inputs into, transformation within, and removal from the atmosphere. Major inputs arise from both anthropogenic and biogenic activities. Transformations arise from oxidation, neutralization, and other chemical reactions. Advection causes dilution and the main removal processes are dry deposition (governed by gravitation and diffusion) and rain. The admixture of sources can be discerned from their isotopic signatures whereas transformations and removal can be followed from the isotopic fractionation that might occur. In this chapter, the atmospheric sulphur cycle and the associated chemistry are summarized. Also presented is information on natural isotopic variations and fundamental concepts relating to the use of isotopic data to delineate anthropogenic S in the atmosphere. Examples of successful applications of these concepts are given. Finally, consideration is given to the potential of using isotopically enriched sulphur to study transport and transformation of atmospheric S compounds. Refs, figs and tabs

  4. Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis

    Science.gov (United States)

    Gelhaus, Stacy L.; Mesaros, A. Clementina; Blair, Ian A.

    2011-01-01

    The metabolism of fatty acids, such as arachidonic acid (AA) and linoleic acid (LA), results in the formation of oxidized bioactive lipids, including numerous stereoisomers1,2. These metabolites can be formed from free or esterified fatty acids. Many of these oxidized metabolites have biological activity and have been implicated in various diseases including cardiovascular and neurodegenerative diseases, asthma, and cancer3-7. Oxidized bioactive lipids can be formed enzymatically or by reactive oxygen species (ROS). Enzymes that metabolize fatty acids include cyclooxygenase (COX), lipoxygenase (LO), and cytochromes P450 (CYPs)1,8. Enzymatic metabolism results in enantioselective formation whereas ROS oxidation results in the racemic formation of products. While this protocol focuses primarily on the analysis of AA- and some LA-derived bioactive metabolites; it could be easily applied to metabolites of other fatty acids. Bioactive lipids are extracted from cell lysate or media using liquid-liquid (l-l) extraction. At the beginning of the l-l extraction process, stable isotope internal standards are added to account for errors during sample preparation. Stable isotope dilution (SID) also accounts for any differences, such as ion suppression, that metabolites may experience during the mass spectrometry (MS) analysis9. After the extraction, derivatization with an electron capture (EC) reagent, pentafluorylbenzyl bromide (PFB) is employed to increase detection sensitivity10,11. Multiple reaction monitoring (MRM) is used to increase the selectivity of the MS analysis. Before MS analysis, lipids are separated using chiral normal phase high performance liquid chromatography (HPLC). The HPLC conditions are optimized to separate the enantiomers and various stereoisomers of the monitored lipids12. This specific LC-MS method monitors prostaglandins (PGs), isoprostanes (isoPs), hydroxyeicosatetraenoic acids (HETEs), hydroxyoctadecadienoic acids (HODEs), oxoeicosatetraenoic

  5. Experimental investigation of sulphur isotope partitioning during outgassing of hydrogen sulphide from diluted aqueous solutions and seawater.

    Science.gov (United States)

    Baune, Claudia; Bottcher, Michael E

    2010-12-01

    The diffusion of hydrogen sulphide across the sediment-water interface and subsequent liberation to the atmosphere may occur in iron-deficient coastal marine environments with enhanced microbial activity in surface sediments and corresponding accumulation of dissolved H2S in near-surface pore waters. The involvement of analogue processes in periods of global mass extinctions during Earth's history (e.g. at the Permian-Triassic boundary) is currently in discussion [L.R. Kump, A. Pavlov, and M. Arthur,Massive Release of Hydrogen Sulfide to the Surface Ocean and Atmosphere During Intervals of Oceanic Anoxia, Geology 33, 397 (2005)]. The outgassing of H₂S is associated with a fractionation of the stable sulphur isotopes, which has so far only been investigated experimentally at selected acidic and neutral pH values, and no experiments with seawater had been carried out. In this communication, we report on sulphur isotope fractionation that takes place during the experimental degassing of H₂S from aqueous solution by an inert gas (N₂) at 21 °C. Experiments were conducted in the pH range between 2.6 and 10.8, corresponding to the dominance fields of dissolved hydrogen sulphide (H₂S(aq)), bisulphide (HS-(aq)), and mixtures of both sulphide species. Overall isotope enrichment factors between -1.6 and +3.0‰ were observed, with the residual dissolved sulphide being enriched or depleted in ³⁴S compared to the liberated H₂S at low and high pH values, respectively. The difference in the low and high pH isotope fractionation effects can be explained by isotope exchange between H₂S(aq) and HS-(aq) [B. Fry, H. Gest, and J.M. Hayes, Sulfur Isotope Effects Associated with Protonation of HS- and Volatilization of H₂S, Chem. Geol. (Isot. Geosci. Sec.) 58, 253 (1986); R. Geßler and K. von Gehlen, Investigation of Sulfur Isotope Fractionation Between H2S Gas and Aqueous Solutions, Fresenius J. Anal. Chem. 324, 130 (1986)] followed by the subsequent transfer of H

  6. Symbols and definitions of quantities and units in isotope stoichiometry

    International Nuclear Information System (INIS)

    Junghans, P.; Krumbiegel, P.; Faust, H.

    1982-01-01

    On the basis of the International System of Units and recent recommendations of the IUPAC on 'Symbols and Terminology for Physicochemical Quantities and Units' a system is proposed of uniform and unambiguous symbols and definitions of quantities and units used in the isotope dilution technique. The close relationship between isotope stoichiometry and common stoichiometry is demonstrated. (author)

  7. NUCLEAR ISOTOPIC DILUTION OF HIGHLY ENRICHED URANIUM BY DRY BLENDING VIA THE RM-2 MILL TECHNOLOGY

    International Nuclear Information System (INIS)

    Rajamani, Raj K.; Latchireddi, Sanjeeva; Devrani, Vikas; Sethi, Harappan; Henry, Roger; Chipman, Nate

    2003-01-01

    DOE has initiated numerous activities to focus on identifying material management strategies to disposition various excess fissile materials. In particular the INEEL has stored 1,700 Kg of offspec HEU at INTEC in CPP-651 vault facility. Currently, the proposed strategies for dispositioning are (a) aqueous dissolution and down blending to LEU via facilities at SRS followed by shipment of the liquid LEU to NFS for fabrication into LWR fuel for the TVA reactors and (b) dilution of the HEU to 0.9% for discard as a waste stream that would no longer have a criticality or proliferation risk without being processed through some type of enrichment system. Dispositioning this inventory as a waste stream via aqueous processing at SRS has been determined to be too costly. Thus, dry blending is the only proposed disposal process for the uranium oxide materials in the CPP-651 vault. Isotopic dilution of HEU to typically less than 20% by dry blending is the key to solving the dispositioning issue (i.e., proliferation) posed by HEU stored at INEEL. RM-2 mill is a technology developed and successfully tested for producing ultra-fine particles by dry grinding. Grinding action in RM-2 mill produces a two million-fold increase in the number of particles being blended in a centrifugal field. In a previous study, the concept of achieving complete and adequate blending and mixing (i.e., no methods were identified to easily separate and concentrate one titanium compound from the other) in remarkably short processing times was successfully tested with surrogate materials (titanium dioxide and titanium mono-oxide) with different particle sizes, hardness and densities. In the current project, the RM-2 milling technology was thoroughly tested with mixtures of natural uranium oxide (NU) and depleted uranium oxide (DU) stock to prove its performance. The effects of mill operating and design variables on the blending of NU/DU oxides were evaluated. First, NU and DU both made of the same oxide

  8. Evaluation for dinitrogen fixation of alfalfa in field based on δ15N value

    International Nuclear Information System (INIS)

    Yao Yunyin; Chen Ming; Zhang Xizhong

    1992-12-01

    The dinitrogen fixation rate of alfalfa was estimated grown in pot and field experiments. β values (isotope fraction factor) of 7 cultivars of alfalfa (Medicago sativa L.) and white clover (Trifolium repens L.) grown in N-free liquid culture medium were examined. Variations in the δ 15 N values of varieties of alfalfa at growing seasons and forage grasses grown under various conditions were measured. %Ndfa of alfalfa was estimated using the natural 15 N abundance method, 15 N isotope dilution method and total N difference, and their accuracy was compared

  9. Application of Isotope Dilution Mass Spectrometry for Reference Measurements of Cadmium. Copper, Mercury, Lead, Zinc and Methyl Mercury in Marine Sediment Sample

    Directory of Open Access Journals (Sweden)

    Vasileva E.

    2013-04-01

    Full Text Available Marine sediment was selected as a test sample for the laboratory inter-comparison studies organized by the Environment Laboratoryes of the International Atomic Energy. The analytical procedure to establish the reference values for the Cd, Cu, Hg, Methyl Hg, Pb and Zn amount contents was based on Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ID ICP-MS applied as a primary method of measurement..The Hg and Methyl Hg determination will be detailed more specifically because of the problems encountered with this element, including sample homogeneity issues, memory effects and possible matrix effects during the ICP- MS measurement stage. Reference values, traceable to the SI, with total uncertainties of less than 2% relative expanded uncertainty (k=2 were obtained for Cd, Cu, Zn and Pb and around 5% for Hg and CH3Hg.

  10. Quantitation of (R)- and (S)-linalool in beer using solid phase microextraction (SPME) in combination with a stable isotope dilution assay (SIDA).

    Science.gov (United States)

    Steinhaus, Martin; Fritsch, Helge T; Schieberle, Peter

    2003-11-19

    A stable isotope dilution assay (SIDA) was developed for the quantitation of both linalool enantiomers using synthesized [2H(2)]R/S-linalool as the internal standard. For enrichment of the target compound from beer, a solid phase microextraction method (SPME) was developed. In comparison to the more time-consuming extraction/distillation cleanup of the beer samples, the results obtained by SPME/SIDA were very similar, even under nonequilibration conditions. Analysis of five different types of beer showed significant differences in the linalool concentrations, which were clearly correlated with the intensity of the hoppy aroma note as evaluated by a sensory panel. In addition, significant differences in the R/S ratios were measured in the beers. The SPME/SIDA yielded exact data independently from headspace sampling parameters, such as exposure time or ionic strength of the solution.

  11. Internal fields on Gd3+ ions diluted in Eu2CuO4

    International Nuclear Information System (INIS)

    Zysler, R.D.

    1990-01-01

    The EPR spectrum of dilute Gd 3+ ions substituting for Eu 3+ in Eu 2 CuO 4 at 9 GHz and 35 GHz in the temperature range of room temperature down 1.5K have been measured. Each one of the resonance lines shows a splitting into two or more weaker lines below T N ∼ 215K. The simultaneous appearance of a low field microwave absorption signal is attributed to the onset of long range antiferromagnetic ordering with a weak ferromagnetic component. The splitting of the EPR spectrum is associated with different Gd sites in the magnetically ordered structure. A reduction of the local symmetry of the rare earth sites below T N is described in terms of an internal magnetic field lying in the ab-plane. Dipolar and exchange contributions to the internal field are discussed. A strong dependence of the GdEPR spectrum and the microwave absorption on the magnetic history of the samples has been observed, suggesting the formation of magnetic domains or a glassy state. (Author) [es

  12. Hydrochemistry and isotopic composition (δ"1"3C, δ"1"5N) in six dunes lagoons in the National Park of Lencois Maranhenses, Maranhao, Brazil

    International Nuclear Information System (INIS)

    Ramos Junior, Jayme Teixeira; Suzuki, Marina Satika; Meirelles, Brunele de Araujo; Rangel, Thiago Pessanha; Oliveira, Braulio Cherene Vaz de

    2015-01-01

    This study aims to evaluate the physicochemical parameters, nutrients and isotopic composition (δ"1"3C, δ"1"5N) of dissolved organic matter and MPS in six lakes located in the Maranhenses National Park, Maranhao State, under varying degrees of anthropic impact and distance from the sea. The physical and chemical parameters were measured in the field with portable devices; for total alkalinity, nutrients and photosynthetic pigments, samples were collected and analysed in the laboratory; the isotopic composition of carbon and nitrogen was determined from the particulate material retained on the filter and in the extract generated in the PPL filtration resin column. The limnological variables were assessed in both the dry and rainy seasons. The high rainfall caused a dilution effect for most of the elements studied in the rainy season. The elemental composition of the particulate fraction was 58% lower than the fraction dissolved. The carbon isotopic composition was lighter in the rainy season as a result of dilution and loading of allochthonous impoverished organic matter. (author)

  13. δ15N values of atmospheric N species simultaneously collected using sector-based samplers distant from sources - Isotopic inheritance and fractionation

    Science.gov (United States)

    Savard, Martine M.; Cole, Amanda; Smirnoff, Anna; Vet, Robert

    2017-08-01

    The nitrogen isotope ratios (δ15N) of atmospheric N species are commonly suggested as indicators of N emission sources. Therefore, numerous research studies have developed analytical methodologies and characterized primary (gases) and secondary emission products (mostly precipitation and aerosols) from various emitters. These previous studies have generally collected either reduced or oxidized N forms, and sampled them separately prior to determining their δ15N values. Distinctive isotopic signals have been reported for emissions from various sources, and seasonality of the δ15N values has been frequently attributed to shifts in relative contributions from sources with different isotopic signals. However, theoretical concepts suggest that temperature effects on isotopic fractionation may also affect the δ15N values of atmospheric reaction products. Here we use a sector-based multi-stage filter system to simultaneously collect seven reduced and oxidized N species downwind from five different source types in Alberta, Canada. We report δ15N values obtained with a state-of-the-art gold-furnace pre-concentrator online with an isotope ratio mass spectrometer (IRMS) to provide representative results even for oxidized-N forms. We find that equilibrium isotope effects and their temperature dependence play significant roles in determining the δ15N values of the secondary emission products. In the end, seasonal δ15N changes here are mainly caused by temperature effects on fractionation, and the δ15N values of only two N species from one source type can be retained as potential fingerprints of emissions.

  14. Ferromagnetism in diluted magnetic semiconductors: A comparision between AB INITIO mean-field, RPA, and Monte Carlo treatments

    Czech Academy of Sciences Publication Activity Database

    Bouzerar, G.; Kudrnovský, Josef; Bergqist, L.; Bruno, P.

    2003-01-01

    Roč. 68, č. 8 (2003), s. 081203-1 - 081203-4 ISSN 0163-1829 R&D Projects: GA AV ČR IAA1010203 Grant - others:RTN(XX) HPRN-CT-2000-00143 Institutional research plan: CEZ:AV0Z1010914 Keywords : Curie temperature * diluted magnetic semiconductors * mean-field * RPA * Monte-Carlo Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.962, year: 2003

  15. Strontium isotopic signatures of oil-field waters: Applications for reservoir characterization

    Science.gov (United States)

    Barnaby, R.J.; Oetting, G.C.; Gao, G.

    2004-01-01

    The 87Sr/86Sr compositions of formation waters that were collected from 71 wells producing from a Pennsylvanian carbonate reservoir in New Mexico display a well-defined distribution, with radiogenic waters (up to 0.710129) at the updip western part of the reservoir, grading downdip to less radiogenic waters (as low as 0.708903 to the east. Salinity (2800-50,000 mg/L) displays a parallel trend; saline waters to the west pass downdip to brackish waters. Elemental and isotopic data indicate that the waters originated as meteoric precipitation and acquired their salinity and radiogenic 87Sr through dissolution of Upper Permian evaporites. These meteoric-derived waters descended, perhaps along deeply penetrating faults, driven by gravity and density, to depths of more than 7000 ft (2100 m). The 87 Sr/86Sr and salinity trends record influx of these waters along the western field margin and downdip flow across the field, consistent with the strong water drive, potentiometric gradient, and tilted gas-oil-water contacts. The formation water 87Sr/86Sr composition can be useful to evaluate subsurface flow and reservoir behavior, especially in immature fields with scarce pressure and production data. In mature reservoirs, Sr Sr isotopes can be used to differentiate original formation water from injected water for waterflood surveillance. Strontium isotopes thus provide a valuable tool for both static and dynamic reservoir characterization in conjunction with conventional studies using seismic, log, core, engineering, and production data. Copyright ??2004. The American Association of Petroleum Geologist. All rights reserved.

  16. Direct determination of the samarium:neodymium ratio in geological materials by inductively coupled plasma quadrupole mass spectrometry with cryogenic desolvation. Comparison with isotope dilution thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Pin, Christian; Telouk, Philippe; Imbert, J.-L.

    1995-01-01

    A cryogenic desolvation unit in the sample introduction system reduces differences in oxide formation between Sm and Nd to very low levels, enabling the direct, standardless determination of their ratio in bulk solutions by inductively coupled plasma mass spectrometry. The measured values are in reasonably good agreement with those determined by the isotope dilution thermal ionization mass spectrometry (ID-TIMS) reference technique. Although this method cannot, at present, compete with ID-TIMS in terms of precision and accuracy, it is much more straightforward and can be used in geochemistry for studies involving the screening of a large number of samples. (author)

  17. Assay of cortisol with a radioimmunoassay method calibrated by isotope dilution-mass spectrometry. A Nordic collaborative study

    International Nuclear Information System (INIS)

    Lantto, O.; Lindback, B.; Aakvaag, A.; Bjoerkhem, I.; Damkjaer-Nielsen, M.; Pomoell, U.M.; Helsinki University Hospital

    1983-01-01

    A reference method for serum cortisol, based on isotope dilution-mass spectrometry (ID-MS), was compared with a modified commercial RIA method. The modification solely concerned the calibration standards used in the RIA method. These were replaced by a series of human serum samples, in which the concentration of cortisol had been determined by the reference ID-MS method. Samples were selected to cover the whole range of the standard curve. Serum samples from healthy, untreated subjects with cortisol concentrations 270-1134 nmol/l were analysed with the ID-MS calibrated RIA method in four laboratories, one in each of the four Nordic countries. Mean values based on results from all four laboratories were almost identical with the values obtained with the reference method. Serum samples from 11 patients with endocrine disorders with cortisol concentrations 31-916 nmol/l were analysed in three of the four laboratories. In three of the samples significant differences were observed between the values obtained with the ID-MS and the ID-MS calibrated RIA method. The value obtained with the ID-MS calibrated RIA was however always more accurate than the corresponding value obtained with RIA with the use of a commercial calibration standard. (author)

  18. Determination of ultratrace levels of tributyltin in waters by isotope dilution and gas chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Cea, Andrés; Rodríguez-González, Pablo; Font Cardona, Nuria; Aranda Mares, José Luís; Ballester Nebot, Salomé; García Alonso, J Ignacio

    2015-12-18

    The current EU legislation lays down the Environmental Quality Standards (EQS) of 45 priority substances in surface water bodies. In particular, the concentration of tributyltin (TBT) must not exceed 0.2ngL(-1) and analytical methodologies with a Limit of Quantification (LOQ) equal or below 0.06ngL(-1) are urged to be developed. This work presents a procedure for the determination of ultratrace levels of TBT in water samples by Isotope Dilution and GC-MS/MS operating in Selected Reaction Monitoring (SRM) mode which meets current EU requirements. The method requires the monitorization of five consecutive transitions (287>175 to 291>179) for the sensitive and selective detection of TBT. The measured isotopic distribution of TBT fragment ions was in agreement with the theoretical values computed by a polynomial expansion algorithm. The combined use of Tandem Mass Spectrometry, a sample volume of 250mL, the preconcentration of 1mL of organic phase to 30μL and an injection volume of 25μL by Programmed Temperature Vaporization provided a LOQ of 0.0426ngL(-1) for TBT (calculated as ten times the standard deviation of nine independent blanks). The recovery for TBT calculated in Milli-Q water at the EQS level was 106.3±4%. A similar procedure was also developed for the quantification of dibutyltin (DBT) and monobutyltin (MBT) in water samples showing satisfactory results. The method was finally implemented in a routine testing laboratory to demonstrate its applicability to real samples obtaining quantitative recoveries for TBT at the EQS level in mineral water, river water and seawater. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Phase diagrams of diluted transverse Ising nanowire

    International Nuclear Information System (INIS)

    Bouhou, S.; Essaoudi, I.; Ainane, A.; Saber, M.; Ahuja, R.; Dujardin, F.

    2013-01-01

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J cs exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given

  20. Process for separating U isotopes by infrared excitation

    International Nuclear Information System (INIS)

    Lyon, R.K.; Kaldor, Andrew.

    1976-01-01

    This invention concerns a process for separating a substance into at least two parts in which the isotopic abundances of a given element differ from those of the isotopes of the substance prior to separation. Specifically, the invention concerns a process for the selective excitation of the isotopes of a gaseous phase UF 6 by absorption of infra-red photons, then by selective reaction of UF 6 excited with atomics chlorine, bromine or iodine, forming a product that may be separated by a standard method. The preference criteria of the atomic chlorine, bromine and iodine are related to the thermal dilution problem [fr

  1. Species specific isotope dilution for the accurate and SI traceable determination of arsenobetaine and methylmercury in cuttlefish and prawn

    International Nuclear Information System (INIS)

    Kumkrong, Paramee; Thiensong, Benjaporn; Le, Phuong Mai; McRae, Garnet; Windust, Anthony; Deawtong, Suladda; Meija, Juris; Maxwell, Paulette; Yang, Lu; Mester, Zoltán

    2016-01-01

    Methods based on species specific isotope dilution were developed for the accurate and SI traceable determination of arsenobetaine (AsBet) and methylmercury (MeHg) in prawn and cuttlefish tissues by LC-MS/MS and SPME GC-ICPMS. Quantitation of AsBet and MeHg were achieved by using a "1"3C-enriched AsBet spike (NRC CRM CBET-1) and an enriched spike of Me"1"9"8Hg (NRC CRM EMMS-1), respectively, wherein analyte mass fractions in enriched spikes were determined by reverse isotope dilution using natural abundance AsBet and MeHg primary standards. Purity of these primary standards were characterized by quantitative "1H-NMR with the use of NIST SRM 350b benzoic acid as a primary calibrator, ensuring the final measurement results traceable to SI. Validation of employed methods of ID LC-MS/MS and ID SPME GC-ICPMS was demonstrated by analysis of several biological CRMs (DORM-4, TORT-3, DOLT-5, BCR-627 and BCR-463) with satisfying results. The developed methods were applied for the determination of AsBet and MeHg in two new certified reference materials (CRMs) prawn (PRON-1) and cuttlefish (SQID-1) produced jointly by Thailand Institute of Scientific and Technological Research (TISTR) and National Research Council Canada (NRC). With additional measurements of AsBet using LC-ICPMS with standard additions calibration and external calibration at NRC and TISTR, respectively, certified values of 1.206 ± 0.058 and 13.96 ± 0.54 mg kg"−"1 for AsBet as As (expanded uncertainty, k = 2) were obtained for the new CRMs PRON-1 and SQID-1, respectively. The reference value of 0.324 ± 0.028 mg kg"−"1 as Hg (expanded uncertainty, k = 2) for MeHg was obtained for the SQID-1 based on the results obtained by ID SPME GC-ICPMS method only, whereas MeHg in PRON-1 was found to be < 0.015 mg kg"−"1. It was found that AsBet comprised 69.7% and 99.0% of total As in the prawn and cuttlefish, respectively, whereas MeHg comprised 94.5% of total Hg in cuttlefish. - Highlights:

  2. Design and performance of an ultra-high vacuum scanning tunneling microscope operating at dilution refrigerator temperatures and high magnetic fields.

    Science.gov (United States)

    Misra, S; Zhou, B B; Drozdov, I K; Seo, J; Urban, L; Gyenis, A; Kingsley, S C J; Jones, H; Yazdani, A

    2013-10-01

    We describe the construction and performance of a scanning tunneling microscope capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T) magnetic fields. The fully ultra-high vacuum system features visual access to a two-sample microscope stage at the end of a bottom-loading dilution refrigerator, which facilitates the transfer of in situ prepared tips and samples. The two-sample stage enables location of the best area of the sample under study and extends the experiment lifetime. The successful thermal anchoring of the microscope, described in detail, is confirmed through a base temperature reading of 20 mK, along with a measured electron temperature of 250 mK. Atomically resolved images, along with complementary vibration measurements, are presented to confirm the effectiveness of the vibration isolation scheme in this instrument. Finally, we demonstrate that the microscope is capable of the same level of performance as typical machines with more modest refrigeration by measuring spectroscopic maps at base temperature both at zero field and in an applied magnetic field.

  3. Development of stable isotope dilution assays for the quantitation of Amadori compounds in foods.

    Science.gov (United States)

    Meitinger, Michael; Hartmann, Sandra; Schieberle, Peter

    2014-06-04

    During thermal processing of foods, reducing carbohydrates and amino acids may form 1-amino-1-desoxyketoses named Amadori rearrangement products after the Italian chemist Mario Amadori. Although these compounds are transient intermediates of the Maillard reaction, they are often used as suitable markers to measure the extent of a thermal food processing, such as for spray-dried milk or dried fruits. Several methods are already available in the literature for their quantitation, but measurements are often done with external calibration without addressing losses during the workup procedure. To cope with this challenge, stable isotope dilution assays in combination with LC-MS/MS were developed for the glucose-derived Amadori products of the seven amino acids valine, leucine, isoleucine, phenylalanine, tyrosine, methionine, and histidine using the respective synthesized [(13)C6]-labeled isotopologues as internal standards. The quantitation of the analytes added to a model matrix showed a very good sensitivity with the lowest limits of detection for the Amadori compound of phenylalanine of 0.1 μg/kg starch and 0.2 μg/kg oil, respectively. Also, the standard deviation measured in, for example, wheat beer was only ±2% for this analyte. Application of the method to several foods showed the highest concentrations of the Amadori product of valine in unroasted cocoa (342 mg/kg) as well as in dried bell pepper (3460 mg/kg). In agreement with literature data, drying of foods led to the formation of Amadori products, whereas they were degraded during roasting of, for example, coffee or cocoa. The study presents for the first time results on concentrations of the Amadori compounds of tyrosine and histidine in foods.

  4. Efficient mass calibration of magnetic sector mass spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Roddick, J C

    1997-12-31

    Magnetic sector mass spectrometers used for automatic acquisition of precise isotopic data are usually controlled with Hall probes and software that uses polynomial equations to define and calibrate the mass-field relations required for mass focusing. This procedure requires a number of reference masses and careful tuning to define and maintain an accurate mass calibration. A simplified equation is presented and applied to several different magnetically controlled mass spectrometers. The equation accounts for nonlinearity in typical Hall probe controlled mass-field relations, reduces calibration to a linear fitting procedure, and is sufficiently accurate to permit calibration over a mass range of 2 to 200 amu with only two defining masses. Procedures developed can quickly correct for normal drift in calibrations and compensate for drift during isotopic analysis over a limited mass range such as a single element. The equation is: Field A{center_dot}Mass{sup 1/2} + B{center_dot}(Mass){sup p} where A, B, and p are constants. The power value p has a characteristic value for a Hall probe/controller and is insensitive to changing conditions, thus reducing calibration to a linear regression to determine optimum A and B. (author). 1 ref., 1 tab., 6 figs.

  5. Development of the Melt-Dilute Treatment Technology for Al-Based DOE Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Peacock, H.B.; Adams, T.M.; Iyer, N.C.

    1998-09-01

    Spent foreign and domestic research reactor fuel assemblies will be sent to Savannah River Site and prepared for interim and eventual geologic storage. Many of the fuel plates have been made with high enriched uranium, and during long term storage, the integrity of the fuel maybe effected if the canister is breached. To reduce the potential for criticality, proliferation, and reduce storage volume, a new treatment technology called melt-dilute is being developed at SRS. The technique will melt the spent fuel assemblies and will dilute the isotopic content to below 20%. The process is simple and versatile

  6. An introduction of gauge field by the Lie-isotopic lifting of the Hilbert space

    International Nuclear Information System (INIS)

    Nishioka, M.

    1984-01-01

    It is introduced the gauge field by the Lie-isotopic lifting of the Hilbert space. Our method is different from other's in that the commutator between the isotropic element and the generators of the Lie algebra does not vanish in our case, but vanishes in other cases. Our method uses the Lie-isotopic lifting of the Hilbert space, but others do not use it

  7. Evaluation of matrix effect in isotope dilution mass spectrometry based on quantitative analysis of chloramphenicol residues in milk powder

    International Nuclear Information System (INIS)

    Li, Xiu Qin; Yang, Zong; Zhang, Qing He; Li, Hong Mei

    2014-01-01

    Graphical abstract: -- Highlights: •We develop a strategy to evaluate matrix effect and its impact on the IDMS results. •Matrix effect and IDMS correction factor from different conditions are evaluated. •Ion suppression effect is observed in LLE and HLB pre-treated sample solutions. •Ion enhancement effect is found in MCX pre-treated sample solution. •IDMS correction factor in HLB and MCX solutions in three instruments is close to 1 -- Abstract: In the present study, we developed a comprehensive strategy to evaluate matrix effect (ME) and its impact on the results of isotope dilution mass spectrometry (IDMS) in analysis of chloramphenicol (CAP) residues in milk powder. Stable isotope-labeled internal standards do not always compensate ME, which brings the variation of the ratio (the peak area of analyte/the peak area of isotope). In our investigation, impact factors of this variation were studied in the extraction solution of milk powder using three mass spectrometers coupled with different ion source designs, and deuterium-labeled chloramphenicol (D5-CAP) was used as the internal standard. ME from mobile phases, sample solvents, pre-treatment methods, sample origins and instruments was evaluated, and its impact on the results of IDMS was assessed using the IDMS correction factor (θ). Our data showed that the impact of ME of mobile phase on the correction factor was significantly greater than that of sample solvent. Significant ion suppression and enhancement effects were observed in different pre-treated sample solutions. The IDMS correction factor in liquid–liquid extraction (LLE) and molecular imprinted polymer (MIP) extract with different instruments was greater or less 1.0, and the IDMS correction factor in hydrophilic lipophilic balance (HLB) and mix-mode cation exchange (MCX) extract with different instruments was all close to 1.0. To the instrument coupled with different ion source design, the impact of ME on IDMS quantitative results was

  8. Sq field characteristics at Phu Thuy, Vietnam, during solar cycle 23: comparisons with Sq field in other longitude sectors

    Science.gov (United States)

    Pham Thi Thu, H.; Amory-Mazaudier, C.; Le Huy, M.

    2011-01-01

    Quiet days variations in the Earth's magnetic field (the Sq current system) are compared and contrasted for the Asian, African and American sectors using a new dataset from Vietnam. This is the first presentation of the variation of the Earth's magnetic field (Sq), during the solar cycle 23, at Phu Thuy, Vietnam (geographic latitudes 21.03° N and longitude: 105.95° E). Phu Thuy observatory is located below the crest of the equatorial fountain in the Asian longitude sector of the Northern Hemisphere. The morphology of the Sq daily variation is presented as a function of solar cycle and seasons. The diurnal variation of Phu Thuy is compared to those obtained in different magnetic observatories over the world to highlight the characteristics of the Phu Thuy observations. In other longitude sectors we find different patterns. At Phu Thuy the solar cycle variation of the amplitude of the daily variation of the X component is correlated to the F.10.7 cm solar radiation (~0.74). This correlation factor is greater than the correlation factor obtained in two observatories located at the same magnetic latitudes in other longitude sectors: at Tamanrasset in the African sector (~0.42, geographic latitude ~22.79) and San Juan in the American sector (~0.03, geographic latitude ~18.38). At Phu Thuy, the Sq field exhibits an equinoctial and a diurnal asymmetry: - The seasonal variation of the monthly mean of X component exhibits the well known semiannual pattern with 2 equinox maxima, but the X component is larger in spring than in autumn. Depending of the phase of the sunspot cycle, the maximum amplitude of the X component varies in spring from 30 nT to 75 nT and in autumn from 20 nT to 60 nT. The maximum amplitude of the X component exhibits roughly the same variation in both solstices, varying from about ~20 nT to 50 nT, depending on the position into the solar cycle. - In all seasons, the mean equinoctial diurnal Y component has a morning maximum Larger than the afternoon

  9. Sq field characteristics at Phu Thuy, Vietnam, during solar cycle 23: comparisons with Sq field in other longitude sectors

    Directory of Open Access Journals (Sweden)

    H. Pham Thi Thu

    2011-01-01

    Full Text Available Quiet days variations in the Earth's magnetic field (the Sq current system are compared and contrasted for the Asian, African and American sectors using a new dataset from Vietnam. This is the first presentation of the variation of the Earth's magnetic field (Sq, during the solar cycle 23, at Phu Thuy, Vietnam (geographic latitudes 21.03° N and longitude: 105.95° E. Phu Thuy observatory is located below the crest of the equatorial fountain in the Asian longitude sector of the Northern Hemisphere. The morphology of the Sq daily variation is presented as a function of solar cycle and seasons. The diurnal variation of Phu Thuy is compared to those obtained in different magnetic observatories over the world to highlight the characteristics of the Phu Thuy observations. In other longitude sectors we find different patterns. At Phu Thuy the solar cycle variation of the amplitude of the daily variation of the X component is correlated to the F.10.7 cm solar radiation (~0.74. This correlation factor is greater than the correlation factor obtained in two observatories located at the same magnetic latitudes in other longitude sectors: at Tamanrasset in the African sector (~0.42, geographic latitude ~22.79 and San Juan in the American sector (~0.03, geographic latitude ~18.38. At Phu Thuy, the Sq field exhibits an equinoctial and a diurnal asymmetry: – The seasonal variation of the monthly mean of X component exhibits the well known semiannual pattern with 2 equinox maxima, but the X component is larger in spring than in autumn. Depending of the phase of the sunspot cycle, the maximum amplitude of the X component varies in spring from 30 nT to 75 nT and in autumn from 20 nT to 60 nT. The maximum amplitude of the X component exhibits roughly the same variation in both solstices, varying from about ~20 nT to 50 nT, depending on the position into the solar cycle. – In all seasons, the mean equinoctial diurnal Y component has a morning maximum Larger

  10. Sm-Nd isotope system of oldest granulites of Anabar Shield

    International Nuclear Information System (INIS)

    Spiridonov, V.G.; Sukhanov, M.K.; Karpenko, S.F.; Lyalikov, A.V.; AN SSSR, Moscow

    1991-01-01

    The first results of applying Sm-Nd method for dating the oldest basic and ultrabasic rocks of the Anabar Shield are presented. The content and isotopic composition of Sm and Nd were determined by the methods of mass-spectroscopy with isotopic dilution. The obtained values of metamorphic ages (3063 ± 80 million years) are in good agreement with U-Pb method data for zircon

  11. Phase diagrams of diluted transverse Ising nanowire

    Energy Technology Data Exchange (ETDEWEB)

    Bouhou, S.; Essaoudi, I. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Ainane, A., E-mail: ainane@pks.mpg.de [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Saber, M. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Ahuja, R. [Condensed Matter Theory Group, Department of Physics and Astronomy, Uppsala University, 75120 Uppsala (Sweden); Dujardin, F. [Laboratoire de Chimie et Physique des Milieux Complexes (LCPMC), Institut de Chimie, Physique et Matériaux (ICPM), 1 Bd. Arago, 57070 Metz (France)

    2013-06-15

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J{sub cs} exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given.

  12. Atomic lithium vapor laser isotope separation

    International Nuclear Information System (INIS)

    Olivares, I.E.; Rojas, C.

    2002-01-01

    An atomic vapor laser isotope separation in lithium was performed using tunable diode lasers. The method permits also the separation of the isotopes between the 6 LiD 2 and the 7 LiD 1 lines using a self-made mass separator which includes a magnetic sector and an ion beam designed for lithium. (Author)

  13. Detection of triclocarban and two co-contaminating chlorocarbanilides in US aquatic environments using isotope dilution liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Sapkota, Amir; Heidler, Jochen; Halden, Rolf U.

    2007-01-01

    The antimicrobial compound triclocarban (TCC; 3,4,4'-trichlorocarbanilide; CAS-bar 101-20-2) is a high-production-volume chemical, recently suggested to cause widespread contamination of US water resources. To test this hypothesis, we developed an isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry method for ultratrace analysis of TCC (0.9ng/L detection limit) and analyzed low-volume water samples (200mL) along with primary sludge samples from across the United States. All river water samples (100%) collected downstream of wastewater treatment plants had detectable levels of TCC, as compared to 56% of those taken upstream. Concentrations of TCC (mean+/-standard deviation) downstream of sewage treatment plants (84+/-110ng/L) were significantly higher (P w/w each) in technical grade TCC (99%). Application of the new method for chlorocarbanilide analysis yielded TCC occurrence data for 13 US states, confirmed the role of sewage treatment plants as environmental inputs of TCC, and identified DCC and TetraCC as previously unrecognized pollutants released into the environment alongside TCC

  14. Existing and emerging technologies for measuring stable isotope labelled retinol in biological samples: isotope dilution analysis of body retinol stores.

    Science.gov (United States)

    Preston, Tom

    2014-01-01

    This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has high sensitivity in terms of sample amount and uses high resolution GC, yet its ability to detect low isotope ratios is limited by background noise. LCMSMS may become more accessible for tracer studies. Its ability to measure low level stable isotope tracers may prove superior to GCMS, but it is isotope ratio MS (IRMS) that has been designed specifically for low level stable isotope analysis through accurate analysis of tracer:tracee ratios (the tracee being the unlabelled species). Compound-specific isotope analysis, where GC is interfaced to IRMS, is gaining popularity. Here, individual 13C-labelled compounds are separated by GC, combusted to CO2 and transferred on-line for ratiometric analysis by IRMS at the ppm level. However, commercially-available 13C-labelled retinol tracers are 2 - 4 times more expensive than deuterated tracers. For 2H-labelled compounds, GC-pyrolysis-IRMS has now become more generally available as an operating mode on the same IRMS instrument. Here, individual compounds are separated by GC and pyrolysed to H2 at high temperature for analysis by IRMS. It is predicted that GC-pyrolysis-IRMS will facilitate low level tracer procedures to measure body retinol stores, as has been accomplished in the case of fatty acids and amino acids. Sample size requirements for GC-P-IRMS may exceed those of GCMS, but this paper discusses sample preparation procedures and predicts improvements, particularly in the efficiency of sample introduction.

  15. Atomic lithium vapor laser isotope separation

    CERN Document Server

    Olivares, I E

    2002-01-01

    An atomic vapor laser isotope separation in lithium was performed using tunable diode lasers. The method permits also the separation of the isotopes between the sup 6 LiD sub 2 and the sup 7 LiD sub 1 lines using a self-made mass separator which includes a magnetic sector and an ion beam designed for lithium. (Author)

  16. Stable isotopic composition of perchlorate and nitrate accumulated in plants: Hydroponic experiments and field data.

    Science.gov (United States)

    Estrada, Nubia Luz; Böhlke, J K; Sturchio, Neil C; Gu, Baohua; Harvey, Greg; Burkey, Kent O; Grantz, David A; McGrath, Margaret T; Anderson, Todd A; Rao, Balaji; Sevanthi, Ritesh; Hatzinger, Paul B; Jackson, W Andrew

    2017-10-01

    Natural perchlorate (ClO 4 - ) in soil and groundwater exhibits a wide range in stable isotopic compositions (δ 37 Cl, δ 18 O, and Δ 17 O), indicating that ClO 4 - may be formed through more than one pathway and/or undergoes post-depositional isotopic alteration. Plants are known to accumulate ClO 4 - , but little is known about their ability to alter its isotopic composition. We examined the potential for plants to alter the isotopic composition of ClO 4 - in hydroponic and field experiments conducted with snap beans (Phaseolus vulgaris L.). In hydroponic studies, anion ratios indicated that ClO 4 - was transported from solutions into plants similarly to NO 3 - but preferentially to Cl - (4-fold). The ClO 4 - isotopic compositions of initial ClO 4 - reagents, final growth solutions, and aqueous extracts from plant tissues were essentially indistinguishable, indicating no significant isotope effects during ClO 4 - uptake or accumulation. The ClO 4 - isotopic composition of field-grown snap beans was also consistent with that of ClO 4 - in varying proportions from irrigation water and precipitation. NO 3 - uptake had little or no effect on NO 3 - isotopic compositions in hydroponic solutions. However, a large fractionation effect with an apparent ε ( 15 N/ 18 O) ratio of 1.05 was observed between NO 3 - in hydroponic solutions and leaf extracts, consistent with partial NO 3 - reduction during assimilation within plant tissue. We also explored the feasibility of evaluating sources of ClO 4 - in commercial produce, as illustrated by spinach, for which the ClO 4 - isotopic composition was similar to that of indigenous natural ClO 4 - . Our results indicate that some types of plants can accumulate and (presumably) release ClO 4 - to soil and groundwater without altering its isotopic characteristics. Concentrations and isotopic compositions of ClO 4 - and NO 3 - in plants may be useful for determining sources of fertilizers and sources of ClO 4 - in their growth

  17. Visible sector inflation and the right thermal history in light of Planck data

    International Nuclear Information System (INIS)

    Wang, Lingfei; Pukartas, Ernestas; Mazumdar, Anupam

    2013-01-01

    Inflation creates perturbations for the large scale structures in the universe, but it also dilutes everything. Therefore it is pertinent that the end of inflation must explain how to excite the Standard Model dof along with the dark matter. In this paper we will briefly discuss the role of visible sector inflaton candidates which are embedded within the Minimal Supersymmetric Standard Model (MSSM) and discuss their merit on how well they match the current data from the Planck. Since the inflaton carries the Standard Model charges their decay naturally produces all the relevant dof with no dark/hidden sector radiation and no isocurvature fluctuations. We will first discuss a single supersymmetric flat direction model of inflation and demonstrate what parameter space is allowed by the Planck and the LHC. We will also consider where the perturbations are created by another light field which decays after inflation, known as a curvaton. The late decay of the curvaton can create observable non-Gaussianity. In the end we will discuss the role of a spectator field whose origin may not lie within the visible sector physics, but its sheer presence during inflation can still create all the perturbations responsible for the large scale structures including possible non-Gaussianity, while the inflaton is embedded within the visible sector which creates all the relevant matter including dark matter, but no dark radiation

  18. A unified effective-field renormalization-group framework approach for the quenched diluted Ising models

    Science.gov (United States)

    de Albuquerque, Douglas F.; Fittipaldi, I. P.

    1994-05-01

    A unified effective-field renormalization-group framework (EFRG) for both quenched bond- and site-diluted Ising models is herein developed by extending recent works. The method, as in the previous works, follows up the same strategy of the mean-field renormalization-group scheme (MFRG), and is achieved by introducing an alternative way for constructing classical effective-field equations of state, based on rigorous Ising spin identities. The concentration dependence of the critical temperature, Tc(p), and the critical concentrations of magnetic atoms, pc, at which the transition temperature goes to zero, are evaluated for several two- and three-dimensional lattice structures. The obtained values of Tc and pc and the resulting phase diagrams for both bond and site cases are much more accurate than those estimated by the standard MFRG approach. Although preserving the same level of simplicity as the MFRG, it is shown that the present EFRG method, even by considering its simplest size-cluster version, provides results that correctly distinguishes those lattices that have the same coordination number, but differ in dimensionality or geometry.

  19. Determination of bisphenol A, triclosan and their metabolites in human urine using isotope-dilution liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Provencher, Gilles; Bérubé, René; Dumas, Pierre; Bienvenu, Jean-François; Gaudreau, Eric; Bélanger, Patrick; Ayotte, Pierre

    2014-06-27

    Bisphenol A (BPA) and triclosan (TCS) are ubiquitous environmental phenols exhibiting endocrine disrupting activities that may be involved in various health disorders in humans. There is a need to measure separately free forms and conjugated metabolites because only the former are biologically active. We have developed sensitive methods using isotope-dilution liquid chromatography-tandem mass spectrometry for individual measurements of free BPA and TCS as well as their metabolites, BPA glucuronide (BPAG), BPA monosulfate (BPAS), BPA disulfate (BPADS), TCS glucuronide (TCSG) and TCS sulfate (TCSS) in urine. Comparative analyses of urine samples from 46 volunteers living in the Quebec City area using the new methods and a GC-MS/MS method previously used in our laboratory revealed very strong correlations for total BPA (Spearman's rs=0.862, purine samples (>94% of total urinary concentrations). Unconjugated TCS concentrations represented a small proportion of total TCS species (median=1.6%) but its concentration was likely underestimated due to losses by adsorption to the surface of polypropylene tubes used for sample storage. To our knowledge, we are the first to report levels of free, sulfated and glucuronidated TCS levels in human urine. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Evaluation of accelerated solvent extraction for butyltin speciation in PACS-2 CRM using double-spike isotope dilution-GC/ICPMS.

    Science.gov (United States)

    Encinar, Jorge Ruiz; Rodriguez-González, Pablo; Fernandez, Julio Rodriguez; Alonso, J Ignacio Garcia; Díez, Sergi; Bayona, Josep M; Sanz-Medelt, Alfredo

    2002-10-15

    Pressurized liquid extraction using the accelerated solvent extractor (Dionex ASE 200) has been evaluated for the determination of mono-, di- and tributyltin (MBT, DBT, and TBT, respectively) in PACS-2 certified reference material. A double-enriched spike containing 119Sn-enriched MBT and TBT and 118Sn-enriched DBT allowed for the simultaneous determination of the three butyltin species and the factors governing species interconversion. The stability of the spike was evaluated by reverse isotope dilution experiments covering more than one year with satisfactory results. Quantitative recoveries using ASE for TBT and DBT were obtained at temperatures above 110 degrees C. The effect of the extraction time and number of static cycles was evaluated. Results suggest that extraction efficiency was quantitative with extraction times as low as 10 min for all butyltin species at 110 degrees C. Decomposition reactions were only detected at the higher temperatures assayed (140 and 175 degrees C) and that was only for the degradation of DBT to MBT (approximately 4%). The results found for MBT were approximately 25% higher than the certified value for the PACS-2 sediment reference material in agreement with previous results obtained by ultrasonic and microwave assisted extraction.

  1. Progress in stable isotope analysis and new possibilities of clinical investigations

    International Nuclear Information System (INIS)

    Roth, E.

    1989-01-01

    The use of stable isotopes in medicine rests on three possibilities offered by labelling: identification of an element, a molecule, or a fragment of a molecule along its biological pathway; quantification of biological pools by isotopic dilution; measurement of metabolization rates, and more generally of clearances. Whenever a corporal function experiences a disregulation reflected either by changes in metabolic activity or modifications of the importance of pools of certain molecules, the possibility exists of making use of isotopes in diagnosis. Examples of practical applications of stable isotopes are given and analytical problems that had to be solved are underlined

  2. On-line measurement of 13C/12C and 15N/14N ratios by E/A-diluter-IRMS

    International Nuclear Information System (INIS)

    Foerstel, H.; Boner, M.; Prast, H.

    2001-01-01

    Efficient food control requires rapid procedures for testing source authenticity. Food is produced inside a closed 'isotopic environment' from where it inherits a specific isotopic composition or fingerprint. Isotope ratio mass spectrometry (IRMS) measures isotopic compositions using simple gases like CO 2 or N 2 exclusively. From food samples these gases may be produced by combustion in a commercial CHN analyser (Elemental Analyser, EA). Following GC separation of the combustion gases the elemental content is determined using a thermal conductivity detector (TCD) . The effluent of the EA is coupled to the mass spectrometer via an open split. Because the relative amounts of the bio-elements vary significantly, (often C/N is 25/1 or larger), the amount of analyte gas produced from a single sample must be adjusted e.g. using a diluter. Our diluter configuration can be adjusted to measure repeatedly the 13 C/ 12 C ratio of carbon dioxide in mineral waters, as well as to measure 15 N/ 14 N and 13 C/ 12 C ratios from biological or soil samples simultaneously. In the first application different types of carbon dioxide, produced naturally (well) or technically (process), can be distinguished. The second application offers the possibility to trace the fate of a fertilizer in vineyards by determining the isotopic variation of nitrogen and carbon in soil and vines. (author)

  3. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    be attributed to the reliability of the measured distances which fall off quickly with each shell. Therefore, in ... field and electrical field gradients due to impurities in vanadium [13]. The effective .... Expanding ∆φ(| Rn' |) in power series of u(R0 n), one gets ... The results of each dilute alloy system are presented separately and ...

  4. Introduction to the Physics of Diluted Magnetic Semiconductors

    CERN Document Server

    Gaj, Jan A

    2010-01-01

    The book deals with diluted magnetic semiconductors, a class of materials important to the emerging field of spintronics. In these materials semiconducting properties, both transport and optical, are influenced by the presence of magnetic ions. It concentrates on basic physical mechanisms (e.g. carrier-ion and ion-ion interactions) and resulting phenomena (e.g. magnetic polaron formation and spin relaxation). Introduction to the Physics of Diluted Magnetic Semiconductors is addressed to graduate-level and doctoral students and young researchers entering the field. The authors have been actively involved in the creation of this branch of semiconductor physics.

  5. Geochemical importance of isotopic fractionation during respiration

    International Nuclear Information System (INIS)

    Schleser, G.; Foerstel, H.

    1975-01-01

    In 1935 it was found that atmospheric oxygen contained a relatively greater abundance of the 18 O isotope than did the oxygen bound in water (Dole effect). A major contribution to the fractionation of the stable oxygen isotopes should result from the respiration of microorganisms. In this respect our interest centers on the soil because nearly all organic material produced on land is decomposed within the soil. The oceans are less important because the primary productivity on land is twice the value for the oceans. In a first approach we measured the oxygen isotope fractionation during the respiration of E. coli K12 for different respiration rates. These results, accomplished with a chemostat, indicate that the fractionation factor α of the oxygen isotopes increases with the increasing respiratory activity, measured as Q/sub O 2 /. At low dilution rates or growth rates respectively of about 0.05 h -1 , the fractionation factor amounts to 1.006 increasing to 1.017 at dilution rates of about 1.0 h -1 . The results are interpreted as a kinetic mass fractionation due to the slightly different diffusion coefficients of 16 O 2 and 18 O 16 O. The respiration rates in conjunction with the corresponding fractionation data are compared with the respiration rates of typical soil microorganisms such as Azotobacter, in order to deduce fractionation data for these organisms. This is necessary to calculate a mean global fractionation factor. Understanding the Dole effect with these fractionation processes should finally give us the opportunity to calculate gas-exchange rates between the atmosphere and the oceans, on the basis of the behavior of the stable oxygen isotopes

  6. The use of stable isotope dilution technique to determine the amount of breast milk consumed by infants

    International Nuclear Information System (INIS)

    Sajet, A. S.

    2011-01-01

    Exclusive breast feeding for six months to an infant, followed by the introduction of complementary food and continued with breast feeding is believed to be an optimal way of infants nutrition. There is a shortage in information about the amount of milk obtained from the infant's mother at least partially due to the difficulties associated with quantification of breast milk intake. The old technique, which depends on how the weight of the baby before and after breast feeding from mother, takes time and may be disturbing to the natural feeding pattern. It was possible to overcome these difficulties by using stable isotopes consumed by mother as D ose of deuterium oxide to mother i n particular dilution dose to mother and then move the dose from mother to baby through breast milk and this can calculate the total volume of breast milk consumed by the infant within 14 days since the dose oxide of deuterium consumed at first day. Dose of deuterium oxide to mother can also help to find out if there were any further quantity of water entering the child's body except breast milk, determine body composition for mother and infant, monitor the effects of programs strengthening food for pregnant mothers and lactating women in terms of quantity and quality of milk overnight, in addition to evaluating the effectiveness of programs to strengthen children's food. (author)

  7. Improved Stable Isotope Dilution Assay for Dietary Folates Using LC-MS/MS and Its Application to Strawberries

    Directory of Open Access Journals (Sweden)

    Lisa Striegel

    2018-02-01

    Full Text Available Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate were quantified using 13C-labeled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection, and limit of quantification and revealed to be a precise, sensitive, and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany and Australia were investigated. Total folates varied from 59 to 153 μg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16% of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.

  8. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Moreno, Laura, E-mail: laura.delgado@eez.csic.es; Wu, Laosheng; Gan, Jay

    2015-08-15

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C{sub free}). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r{sup 2} > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems.

  9. Improved stable isotope dilution assay for dietary folates using LC-MS/MS and its application to strawberries

    Science.gov (United States)

    Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael

    2018-02-01

    Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate and 5-formyltetrahydrofolate were quantified using 13C-labelled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection and limit of quantification and revealed to be a precise, sensitive and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany were investigated. Total folates varied from 59 to 153 µg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16 % of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.

  10. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    International Nuclear Information System (INIS)

    Delgado-Moreno, Laura; Wu, Laosheng; Gan, Jay

    2015-01-01

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C free ). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r 2 > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems

  11. The dilution effect on the extinction of wall diffusion flame

    Directory of Open Access Journals (Sweden)

    Ghiti Nadjib

    2014-12-01

    Full Text Available The dynamic process of the interaction between a turbulent jet diffusion methane flame and a lateral wall was experimentally studied. The evolution of the flame temperature field with the Nitrogen dilution of the methane jet flame was examined. The interaction between the diffusion flame and the lateral wall was investigated for different distance between the wall and the central axes of the jet flame. The dilution is found to play the central role in the flame extinction process. The flame response as the lateral wall approaches from infinity and the increasing of the dilution rate make the flame extinction more rapid than the flame without dilution, when the nitrogen dilution rate increase the flame temperature decrease.

  12. Estimation of nitrogen fixation in Saccharum spp. by 15N dilution method

    International Nuclear Information System (INIS)

    Singh, Mohan

    1994-01-01

    The amount of nitrogen fixed by bacteria associated with the roots of Saccharum spontaneum, S. sinense, and S. barberi has been estimated by 15 N-isotope dilution method using Sclerotachya fusca as a non-fixing control. S. spontaneum produced highest shoot dry weight among the species tested but maximum nitrogen was accumulated by S. barberi. Highest dilution in the 15 N-enrichment was observed in S. spontaneum followed by S. sinense and S. barberi in comparison to the control plant of Sclerotchya fusca. S. spontaneum derived 60 per cent followed by S. sinense 54 per cent and S. barberi 35 per cent of their total nitrogen requirement through fixation of nitrogen by diazotrophic bacteria associated with their roots. (author). 11 refs., 2 tabs

  13. Analysis of stable isotope data to estimate vitamin A body stores

    International Nuclear Information System (INIS)

    2008-06-01

    Vitamin A deficiency (VAD) is a serious public health problem in most developing countries. Because of the detrimental effects of vitamin A deficiency on human health, accurate assessment of vitamin A status is necessary to develop and evaluate intervention programmes. The IAEA is providing technical support to its Member States to use stable isotope dilution techniques to develop and evaluate programmes aimed at reducing vitamin A deficiency in populations. The stable isotope dilution technique, in contrast to other methods, have the potential to provide a quantitative estimate of vitamin A concentration across the continuum of status, from deficient to excess vitamin A body stores. In 2004 the IAEA, the United States Agency for International Development (USAID) and HarvestPlus initiated the Vitamin A Tracer Task Force, made up of international experts. HarvestPlus is a Global Challenge Program of the Consultative Group on International Agricultural Research (CGIAR). It is coordinated by the Centro Internacional de Agricultura Tropical (CIAT), a not-for-profit organization that conducts socially and environmentally progressive research aimed at reducing hunger and poverty and preserving natural resources in developing countries, located in Colombia, and the International Food Policy Research Institute (IFPRI), located in the United States of America and whose mission is to provide policy solutions aimed at reducing hunger and malnutrition in developing countries. The role of the Vitamin A Tracer Task Force was to prepare three complementary publications on the use of stable isotope dilution techniques to assess vitamin A body stores. The first publication entitled 'Appropriate Use of Vitamin A Tracer (Stable Isotope) Methodology' was published in 2004 by USAID/International Life Sciences Institute (ILSI) through the Micronutrient Global Leadership (MGL) project with co-sponsorship of IAEA and HarvestPlus. The second handbook is on 'Vitamin A Tracer Dilution

  14. Predicting the solubility and lability of Zn, Cd, and Pb in soils from a minespoil-contaminated catchment by stable isotopic exchange

    Science.gov (United States)

    Marzouk, E. R.; Chenery, S. R.; Young, S. D.

    2013-12-01

    The Rookhope catchment of Weardale, England, has a diverse legacy of contaminated soils due to extensive lead mining activity over four centuries. We measured the isotopically exchangeable content of Pb, Cd and Zn (E-values) in a large representative subset of the catchment soils (n = 246) using stable isotope dilution. All three metals displayed a wide range of %E-values (c. 1-100%) but relative lability followed the sequence Cd > Pb > Zn. A refinement of the stable isotope dilution approach also enabled detection of non-reactive metal contained within suspended sub-micron (dilution, in a diverse range of soil ecosystems within the catchment of an old Pb/Zn mining area. Assess the controlling influences of soil properties on metal lability and develop predictive algorithms for metal lability in the contaminated catchment based on simple soil properties (such as pH, organic matter (LOI), and total metal content). Examine the incidence of non-isotopically-exchangeable metal held within suspended colloidal particles (SCP-metal) in filtered soil solutions (<0.22 μm) by comparing E-values from isotopic abundance in solutions equilibrated with soil and in a resin phase equilibrated with the separated solution. Assess the ability of a geochemical speciation model, WHAM(VII), to predict metal solubility using isotopically exchangeable metal as an input variable.

  15. Nuclear isotope measurement in the Hanford environment

    International Nuclear Information System (INIS)

    Wacker, J.F.; Stoffel, J.J.; Kelley, J.M.

    1995-01-01

    The Pacific Northwest Laboratory (PNL) is located at the federal government's Hanford Site in southeastern Washington State, which was built during World War II as part of the secret Manhattan Project to develop the atomic bomb. Monitoring of the Site itself and surrounding environs for Hanford-related radionuclides has been a routine part of the operations since 1944. One of the most sensitive analytical methods used is thermal ionization mass spectrometry (TIMS) with triple-sector mass spectrometers. Normal geometry instruments have an abundance sensitivity of 10 -9 for uranium while the authors' newest Triple-Sector Isotope Mass Spectrometer (TRISM), utilizing a new ion-optical design developed at PNL, has an abundance sensitivity of 10 -11 . In favorable cases, sensitivity is such that complete isotopic analyses are obtained on total samples in the femtogram range; and minor isotopes in the attogram range are measured

  16. Species specific isotope dilution for the accurate and SI traceable determination of arsenobetaine and methylmercury in cuttlefish and prawn

    Energy Technology Data Exchange (ETDEWEB)

    Kumkrong, Paramee [National Research Council Canada, 1200 Montreal Rd, Ottawa, Ontario, K1A 0R6 (Canada); Thailand Institute of Scientific and Technological Research, 35 Mu 3 Tambon Khlong Ha, Amphoe Khlong Luang, Pathum Thani, 12120 (Thailand); Thiensong, Benjaporn [Thailand Institute of Scientific and Technological Research, 35 Mu 3 Tambon Khlong Ha, Amphoe Khlong Luang, Pathum Thani, 12120 (Thailand); Le, Phuong Mai; McRae, Garnet; Windust, Anthony [National Research Council Canada, 1200 Montreal Rd, Ottawa, Ontario, K1A 0R6 (Canada); Deawtong, Suladda [Thailand Institute of Scientific and Technological Research, 35 Mu 3 Tambon Khlong Ha, Amphoe Khlong Luang, Pathum Thani, 12120 (Thailand); Meija, Juris; Maxwell, Paulette [National Research Council Canada, 1200 Montreal Rd, Ottawa, Ontario, K1A 0R6 (Canada); Yang, Lu, E-mail: Lu.yang@nrc-cnrc.gc.ca [National Research Council Canada, 1200 Montreal Rd, Ottawa, Ontario, K1A 0R6 (Canada); Mester, Zoltán [National Research Council Canada, 1200 Montreal Rd, Ottawa, Ontario, K1A 0R6 (Canada)

    2016-11-02

    Methods based on species specific isotope dilution were developed for the accurate and SI traceable determination of arsenobetaine (AsBet) and methylmercury (MeHg) in prawn and cuttlefish tissues by LC-MS/MS and SPME GC-ICPMS. Quantitation of AsBet and MeHg were achieved by using a {sup 13}C-enriched AsBet spike (NRC CRM CBET-1) and an enriched spike of Me{sup 198}Hg (NRC CRM EMMS-1), respectively, wherein analyte mass fractions in enriched spikes were determined by reverse isotope dilution using natural abundance AsBet and MeHg primary standards. Purity of these primary standards were characterized by quantitative {sup 1}H-NMR with the use of NIST SRM 350b benzoic acid as a primary calibrator, ensuring the final measurement results traceable to SI. Validation of employed methods of ID LC-MS/MS and ID SPME GC-ICPMS was demonstrated by analysis of several biological CRMs (DORM-4, TORT-3, DOLT-5, BCR-627 and BCR-463) with satisfying results. The developed methods were applied for the determination of AsBet and MeHg in two new certified reference materials (CRMs) prawn (PRON-1) and cuttlefish (SQID-1) produced jointly by Thailand Institute of Scientific and Technological Research (TISTR) and National Research Council Canada (NRC). With additional measurements of AsBet using LC-ICPMS with standard additions calibration and external calibration at NRC and TISTR, respectively, certified values of 1.206 ± 0.058 and 13.96 ± 0.54 mg kg{sup −1} for AsBet as As (expanded uncertainty, k = 2) were obtained for the new CRMs PRON-1 and SQID-1, respectively. The reference value of 0.324 ± 0.028 mg kg{sup −1} as Hg (expanded uncertainty, k = 2) for MeHg was obtained for the SQID-1 based on the results obtained by ID SPME GC-ICPMS method only, whereas MeHg in PRON-1 was found to be < 0.015 mg kg{sup −1}. It was found that AsBet comprised 69.7% and 99.0% of total As in the prawn and cuttlefish, respectively, whereas MeHg comprised 94.5% of total Hg in

  17. Metabolic studies in man using stable isotopes

    International Nuclear Information System (INIS)

    Faust, H.; Jung, K.; Krumbiegel, P.

    1993-01-01

    In this project, stable isotope compounds and stable isotope pharmaceuticals were used (with emphasis on the application of 15 N) to study several aspects of nitrogen metabolism in man. Of the many methods available, the 15 N stable isotope tracer technique holds a special position because the methodology for application and nitrogen isotope analysis is proven and reliable. Valid routine methods using 15 N analysis by emission spectrometry have been demonstrated. Several methods for the preparation of biological material were developed during our participation in the Coordinated Research Programme. In these studies, direct procedures (i.e. use of diluted urine as a samples without chemical preparation) or rapid isolation methods were favoured. Within the scope of the Analytical Quality Control Service (AQCS) enriched stable isotope reference materials for medical and biological studies were prepared and are now available through the International Atomic Energy Agency. The materials are of special importance as the increasing application of stable isotopes as tracers in medical, biological and agricultural studies has focused interest on reliable measurements of biological material of different origin. 24 refs

  18. Calculation of turnover rates in stable-isotope studies

    International Nuclear Information System (INIS)

    Wootton, R.; Ford, G.C.; Cheng, K.N.; Halliday, D.

    1985-01-01

    In a comparison of glucose turnover measured with 2 H-glucose and with 13 C-glucose Tserng and Kalhan used five apparently different equations and obtained conflicting answers. There is, however, no difference in principle between the use of a stable isotope as a tracer and the use of a radioactive isotope, and the rate of appearance of tracee in a steady-state system (the turnover) can therefore be shown to be proportional to the equilibrium dilution of the infused tracer. Because the sensitivity of measurement of this dilution made using a gas chromatograph-mass spectrometer is lower than that made by radioactivity measurement, the contribution to the measured turnover rate due to the infusate cannot be neglected, as it usually is in radioisotope work. A convenient calibration curve to establish this dilution is the mole ratio of the pure infusate against the area ratio for the relevant ions. Tserng and Kalhan's apparently conflicting results for glucose-turnover using 13 C-glucose as the tracer can all be shown to amount to approximately 11.6 μmol min -1 kg -1 . This value is only slightly lower (0.05 2 H-glucose as the tracer and supports the use of 13 C-glucose as an alternative. (author)

  19. Stable isotopes in mid-ocean ridge hydrothermal systems: Interactions between fluids, minerals, and organisms

    Science.gov (United States)

    Shanks, W. C., III; Böhlke, J. K.; Seal, R. R., II

    Studies of abundance variations of light stable isotopes in nature have had a tremendous impact on all aspects of geochemistry since the development, in 1947, of a gas source isotope ratio mass spectrometer capable of measuring small variations in stable isotope ratios [Nier, 1947] Stable isotope geochemistry is now a mature field, as witnessed by the proliferation of commercially available mass spectrometers installed at virtually every major academic, government, and private-sector research geochemistry laboratory. A recent search of a literature database revealed over 3,000 articles that utilized stable isotope geochemistry over the last 20 years. Nonetheless, many exciting new technical developments are leading to exciting new discoveries and applications. In particular, micro analytical techniques involving new generations of laser- and ion-microprobes are revolutionizing the types of analyses that can be done on spot sizes as small as a few tens of micrometers [Shanks and Criss, 1989]. New generations of conventional gas source and thermal ionization mass spectrometers, with high levels of automation and increased sensitivity and precision, are allowing analyses of large numbers of samples, like those needed for stable isotope stratigraphy in marine sediments, and are enabling the development and application of new isotopic systems.

  20. Full quantification of selenium species by RP and AF-ICP-qMS with on-line isotope dilution in serum samples from mercury-exposed people supplemented with selenium-enriched yeast

    DEFF Research Database (Denmark)

    Li, Yu-Feng; Hu, Liang; Li, Bai

    2011-01-01

    and affinity chromatography (AF) hyphenated to inductively coupled plasma-(quadrupole) mass spectrometry (ICP-qMS) with post-column isotope dilution analysis (IDA) and a collision cell technique (CCT). Different Se species like inorganic Se (Se4+ and Se6+), selenocystine (SeCys), selenomethionine (Se...... L−1 for GPx and other non-retained Se compounds, 1.0 μg Se L−1 for SelP and 1.2 μg Se L−1 for SeAlb, 1.3 μg Se L−1 for inorganic Se; 1.2 μg Se L−1 for SeCys; 1.1 μg Se L−1 for SeMet, respectively....

  1. Stable Isotope Group 1983 progress report

    International Nuclear Information System (INIS)

    Stewart, M.K.

    1984-06-01

    The work of the Stable Isotope Group of the Institute of Nuclear Sciences in the fields of isotope geology, isotope hydrology, geochronology, isotope biology and related fields, and mass spectrometer instrumentation, during 1983, is described

  2. Effect of time course application of nitrogen fertilizer on the N-fertilizer use efficiency, lint properties and seed cotton yield using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Janat, M.; Khalifa, Kh

    2001-12-01

    Field experiment was carried out at Der El-Hajar research station during 1998 growing season to evaluate the effect of time course application of nitrogen fertilizer on N-recovery, seed cotton yield and lint properties using 15 N isotope dilution technique. Aleppo 40 variety was tested, irrigation scheduling was set up at 80% of field capacity. Phosphorus fertilizer was applied as TSP 46% before planting at a rate of 180 kg/ha. N fertilizer was applied as urea (46%) in four different applications follows: one application 180 kg N/ha before planting (T1), two split application 180 (90 + 90) kg N/ha (T2), three equally split applications 180 (60 + 60 + 60) kg N/ha (T3), and four equally split applications 180 (45 + 45 + 45 + 45) kg N/ha (T4). Labeled N-fertilizer (5.09 a.e%) was also applied as urea 46% to the subplots (1.0 m 2 each) of the corresponding treatments. All agricultural practices were carried out as the common practices locally employed. Soil samples were analyzed for CEC, ph, EC, OM, total N, available P, and CaCO 3 as outlined by our laboratory standard procedure. Plant samples were collected at physiological maturity and analyzed for 15 N enrichment to assess N recovery. Lint samples were analyzed for lint properties. the results showed no significant effect of the nitrogen fertilizer time course application on the tested parameters such as dry matter production, seed cotton yield, N uptake and lint properties. on the other hand the T2, T3 and T4 treatments where shown to have a positive significant response toward time course application relative to T1 treatment. (authors)

  3. Biological and chemical assessments of zinc ageing in field soils

    International Nuclear Information System (INIS)

    Donner, Erica; Broos, Kris; Heemsbergen, Diane; Warne, Michael St. J.; McLaughlin, Mike J.; Hodson, Mark E.; Nortcliff, Stephen

    2010-01-01

    As zinc (Zn) is both an essential trace element and potential toxicant, the effects of Zn fixation in soil are of practical significance. Soil samples from four field sites amended with ZnSO 4 were used to investigate ageing of soluble Zn under field conditions over a 2-year period. Lability of Zn measured using 65 Zn radioisotope dilution showed a significant decrease over time and hence evidence of Zn fixation in three of the four soils. However, 0.01 M CaCl 2 extractions and toxicity measurements using a genetically modified lux-marked bacterial biosensor did not indicate a decrease in soluble/bioavailable Zn over time. This was attributed to the strong regulatory effect of abiotic properties such as pH on these latter measurements. These results also showed that Zn ageing occurred immediately after Zn spiking, emphasising the need to incubate freshly spiked soils before ecotoxicity assessments. - Ageing effects were detected in Zn-amended field soils using 65 Zn isotopic dilution as a measure of lability, but not with either CaCl 2 extractions or a lux-marked bacterial biosensor.

  4. Evaluation of the isotopic dilution method with addition of 15 N fertilizer to the soil, for quantification of BNF by legumes

    International Nuclear Information System (INIS)

    Morales, E.R.B.

    1990-01-01

    Two pot experiments were carried out in greenhouse, with the objective of evaluating the isotopic dilution method with the addition of 15 N fertilizer to the soil for evaluation of biological nitrogen fixation (BNF) by legumes. Experiment I: with addition of 15 N-fertilizer, according to FRIED and MIDDELBOE (1977), and Experiment II: Without adding the fertilizer, by natural variation of 15 N (δ 15 N). In experiment I, the following crops were utilized as test plants: soybean, bean and cowpea and for the control plants: non nodulating soybean, rice and wheat, with distinct number of plants per pot. The pots containing 8 Kg a Dark red latossol (LE) of Sao Paulo state, Brazil, received the same rate of nitrogen fertilizer with same 15 N enrichment. In experiment II, bean was utilized as test crop and non nodulating soybean and rice as controls, and they did not receive any nitrogen fertilizer. The experiments lasted 81 days, from July to October 1989. The above ground parts of the plants were harvested, for which dry matter weight, total-N and 15 N were determined. (author)

  5. Effects of Conventional Heating on the Stability of Major Olive Oil Phenolic Compounds by Tandem Mass Spectrometry and Isotope Dilution Assay

    Directory of Open Access Journals (Sweden)

    Giovanni Sindona

    2010-12-01

    Full Text Available The quality of olive oils is sensorially tested by accurate and well established methods. It enables the classification of the pressed oils into the classes of extra virgin oil, virgin oil and lampant oil. Nonetheless, it would be convenient to have analytical methods for screening oils or supporting sensorial analysis using a reliable independent approach based on exploitation of mass spectrometric methodologies. A number of methods have been proposed to evaluate deficiencies of extra virgin olive oils resulting from inappropriate technological treatments, such as high or low temperature deodoration, and home cooking processes. The quality and nutraceutical value of extra virgin olive oil (EVOO can be related to the antioxidant property of its phenolic compounds. Olive oil is a source of at least 30 phenolic compounds, such as oleuropein, oleocanthal, hydroxytyrosol, and tyrosol, all acting as strong antioxidants, radical scavengers and NSAI-like drugs. We now report the efficacy of MRM tandem mass spectrometry, assisted by the isotope dilution assay, in the evaluation of the thermal stability of selected active principles of extra virgin olive oil.

  6. Effects of conventional heating on the stability of major olive oil phenolic compounds by tandem mass spectrometry and isotope dilution assay.

    Science.gov (United States)

    Attya, Mohamed; Benabdelkamel, Hicham; Perri, Enzo; Russo, Anna; Sindona, Giovanni

    2010-12-01

    The quality of olive oils is sensorially tested by accurate and well established methods. It enables the classification of the pressed oils into the classes of extra virgin oil, virgin oil and lampant oil. Nonetheless, it would be convenient to have analytical methods for screening oils or supporting sensorial analysis using a reliable independent approach based on exploitation of mass spectrometric methodologies. A number of methods have been proposed to evaluate deficiencies of extra virgin olive oils resulting from inappropriate technological treatments, such as high or low temperature deodoration, and home cooking processes. The quality and nutraceutical value of extra virgin olive oil (EVOO) can be related to the antioxidant property of its phenolic compounds. Olive oil is a source of at least 30 phenolic compounds, such as oleuropein, oleocanthal, hydroxytyrosol, and tyrosol, all acting as strong antioxidants, radical scavengers and NSAI-like drugs. We now report the efficacy of MRM tandem mass spectrometry, assisted by the isotope dilution assay, in the evaluation of the thermal stability of selected active principles of extra virgin olive oil.

  7. Near-field multiple traps of paraxial acoustic vortices with strengthened gradient force generated by sector transducer array

    Science.gov (United States)

    Wang, Qingdong; Li, Yuzhi; Ma, Qingyu; Guo, Gepu; Tu, Juan; Zhang, Dong

    2018-01-01

    In order to improve the capability of particle trapping close to the source plane, theoretical and experimental studies on near-field multiple traps of paraxial acoustic vortices (AVs) with a strengthened acoustic gradient force (AGF) generated by a sector transducer array were conducted. By applying the integration of point source radiation, numerical simulations for the acoustic fields generated by the sector transducer array were conducted and compared with those produced by the circular transducer array. It was proved that strengthened AGFs of near-field multiple AVs with higher peak pressures and smaller vortex radii could be produced by the sector transducer array with a small topological charge. The axial distributions of the equivalent potential gradient indicated that the AGFs of paraxial AVs in the near field were much higher than those in the far field, and the distances at the near-field vortex antinodes were also proved to be the ideal trapping positions with relatively higher AGFs. With the established 8-channel AV generation system, theoretical studies were also verified by the experimental measurements of pressure and phase for AVs with various topological charges. The formation of near-field multiple paraxial AVs was verified by the cross-sectional circular pressure distributions with perfect phase spirals around central pressure nulls, and was also proved by the vortex nodes and antinodes along the center axis. The favorable results demonstrated the feasibility of generating near-field multiple traps of paraxial AVs with strengthened AGF using the sector transducer array, and suggested the potential applications of close-range particle trapping in biomedical engineering.

  8. Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo

    OpenAIRE

    Boulyga, S. F.; Testa, C.; Desideri, D.; Becker, J. S.

    2001-01-01

    The determination of environmental contamination with natural and artificial actinide isotopes and evaluation of their source requires precise isotopic determination of actinides, above all uranium and plutonium. This can be achieved by alpha spectrometry or by inductively coupled plasma mass spectrometry (ICP-MS) after chemical separation of actinides. The performance of a sector-field ICP-MS (ICP-SFMS) coupled to a low-flow micronebulizer with a membrane desolvation unit, "Aridus'', was stu...

  9. Isotopes in heterogeneous catalysis

    CERN Document Server

    Hargreaves, Justin SJ

    2006-01-01

    The purpose of this book is to review the current, state-of-the-art application of isotopic methods to the field of heterogeneous catalysis. Isotopic studies are arguably the ultimate technique in in situ methods for heterogeneous catalysis. In this review volume, chapters have been contributed by experts in the field and the coverage includes both the application of specific isotopes - Deuterium, Tritium, Carbon-14, Sulfur-35 and Oxygen-18 - as well as isotopic techniques - determination of surface mobility, steady state transient isotope kinetic analysis, and positron emission profiling.

  10. Development of the NBS beryllium isotopic standard reference material

    International Nuclear Information System (INIS)

    Inn, K.G.W; Fassett, J.D.; Coursey, B.M.; Walker, R.L.; Raman, S.

    1987-01-01

    The National Bureau of Standards, in conjunction with the Oak Ridge National Laboratory and the Accelerator Mass Spectrometry community, is in the process of developing a beryllium isotopic solution Standard Reference Material. The master 10 Be/ 9 Be solution was characterized isotopically by resonance-ionization and secondary-ion mass-spectrometric-based techniques, and radioactivity measurements were by liquid scintillation counting. The master solution was gravimetrically diluted with 9 Be to a final 10 Be/ 9 Be atomic ratio of 3 x 10 -11 . The preliminary data indicate a half life for 10 Be of 1.3 million years, and AMS measurements are within 10% of the known beryllium isotopic ratio

  11. The Vlasov equation with strong magnetic field and oscillating electric field as a model for isotop resonant separation

    Directory of Open Access Journals (Sweden)

    Emmanuel Frenod

    2002-01-01

    Full Text Available We study the qualitative behavior of solutions to the Vlasov equation with strong external magnetic field and oscillating electric field. This model is relevant to the understanding of isotop resonant separation. We show that the effective equation is a kinetic equation with a memory term. This memory term involves a pseudo-differential operator whose kernel is characterized by an integral equation involving Bessel functions. The kernel is explicitly given in some particular cases.

  12. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  13. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  14. Application of heavy stable isotopes in forensic isotope geochemistry: A review

    International Nuclear Information System (INIS)

    Aggarwal, Jugdeep; Habicht-Mauche, Judith; Juarez, Chelsey

    2008-01-01

    Light stable isotopes have been used for many years to characterize the source and transport of materials. More recently heavy isotope systems such as Sr, Nd and Pb have been added to this list in order to aid source identification. With the advent of multiple collector ICP-MS, the range of isotopic tools now available has increased considerably, however, until the isotope systematics of these new non-traditional isotope systems have become better understood, they will not be as useful in characterizing material source and transportation. Applications using heavy metal stable isotopes (mostly traditional heavy isotopes) have reached most avenues in science, including earth sciences, archaeology, anthropology, animal physiology, ecology and toxicology. This field will continue to grow as new applications are developed and techniques become simpler and quicker. This paper provides a review of how this field has grown and presents two new applications using Pb and Sr isotopes in glazes to determine the source of ore used in glazes, and using Sr isotopes to determine the origin of undocumented deceased Mexican border crossers

  15. Application of heavy stable isotopes in forensic isotope geochemistry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, Jugdeep [W.M. Keck Isotope Laboratory, Department of Earth Sciences, University of California, Santa Cruz, CA 95064 (United States)], E-mail: jaggarwal@pmc.ucsc.edu; Habicht-Mauche, Judith; Juarez, Chelsey [Department of Anthropology, University of California, Santa Cruz, CA 95064 (United States)

    2008-09-15

    Light stable isotopes have been used for many years to characterize the source and transport of materials. More recently heavy isotope systems such as Sr, Nd and Pb have been added to this list in order to aid source identification. With the advent of multiple collector ICP-MS, the range of isotopic tools now available has increased considerably, however, until the isotope systematics of these new non-traditional isotope systems have become better understood, they will not be as useful in characterizing material source and transportation. Applications using heavy metal stable isotopes (mostly traditional heavy isotopes) have reached most avenues in science, including earth sciences, archaeology, anthropology, animal physiology, ecology and toxicology. This field will continue to grow as new applications are developed and techniques become simpler and quicker. This paper provides a review of how this field has grown and presents two new applications using Pb and Sr isotopes in glazes to determine the source of ore used in glazes, and using Sr isotopes to determine the origin of undocumented deceased Mexican border crossers.

  16. Dark sector impact on gravitational collapse of an electrically charged scalar field

    Energy Technology Data Exchange (ETDEWEB)

    Nakonieczna, Anna [Institute of Physics, Maria Curie-Skłodowska University,Plac Marii Curie-Skłodowskiej 1, 20-031 Lublin (Poland); Institute of Agrophysics, Polish Academy of Sciences,Doświadczalna 4, 20-290 Lublin (Poland); Rogatko, Marek [Institute of Physics, Maria Curie-Skłodowska University,Plac Marii Curie-Skłodowskiej 1, 20-031 Lublin (Poland); Nakonieczny, Łukasz [Institute of Theoretical Physics, Faculty of Physics, University of Warsaw,Pasteura 5, 02-093 Warszawa (Poland)

    2015-11-04

    Dark matter and dark energy are dominating components of the Universe. Their presence affects the course and results of processes, which are driven by the gravitational interaction. The objective of the paper was to examine the influence of the dark sector on the gravitational collapse of an electrically charged scalar field. A phantom scalar field was used as a model of dark energy in the system. Dark matter was modeled by a complex scalar field with a quartic potential, charged under a U(1)-gauge field. The dark components were coupled to the electrically charged scalar field via the exponential coupling and the gauge field-Maxwell field kinetic mixing, respectively. Complete non-linear simulations of the investigated process were performed. They were conducted from regular initial data to the end state, which was the matter dispersal or a singularity formation in a spacetime. During the collapse in the presence of dark energy dynamical wormholes and naked singularities were formed in emerging spacetimes. The wormhole throats were stabilized by the violation of the null energy condition, which occurred due to a significant increase of a value of the phantom scalar field function in its vicinity. The square of mass parameter of the dark matter scalar field potential controlled the formation of a Cauchy horizon or wormhole throats in the spacetime. The joint impact of dark energy and dark matter on the examined process indicated that the former decides what type of an object forms, while the latter controls the amount of time needed for the object to form. Additionally, the dark sector suppresses the natural tendency of an electrically charged scalar field to form a dynamical Reissner-Nordström spacetime during the gravitational collapse.

  17. Parkinson-dementia complex and development of a new stable isotope dilution assay for BMAA detection in tissue

    International Nuclear Information System (INIS)

    Snyder, Laura R.; Cruz-Aguado, Reyniel; Sadilek, Martin; Galasko, Douglas; Shaw, Christopher A.; Montine, Thomas J.

    2009-01-01

    β-Methylamino-L-alanine (BMAA) has been proposed as a global contributor to neurodegenerative diseases, including Parkinson-dementia complex (PDC) of Guam and Alzheimer's disease (AD). The literature on the effects of BMAA is conflicting with some but not all in vitro data supporting a neurotoxic action, and experimental animal data failing to replicate the pattern of neurodegeneration of these human diseases, even at very high exposures. Recently, BMAA has been reported in human brain from individuals afflicted with PDC or AD. Some of the BMAA in human tissue reportedly is freely extractable (free) while some is protein-associated and liberated by techniques that hydrolyze the peptide bond. The latter is especially intriguing since BMAA is a non-proteinogenic amino acid that has no known tRNA. We attempted to replicate these findings with techniques similar to those used by others; despite more than adequate sensitivity, we were unable to detect free BMAA. Recently, using a novel stable isotope dilution assay, we again were unable to detect free or protein-associated BMAA in human cerebrum. Here we review the development of our new assay for tissue detection of BMAA and show that we are able to detect free BMAA in liver but not cerebrum, nor do we detect any protein-associated BMAA in mice fed this amino acid. These studies demonstrate the importance of a sensitive and specific assay for tissue BMAA and seriously challenge the proposal that BMAA is accumulating in human brain.

  18. Preliminary interpretation of isotopic studies of geothermal waters from the Beijing region (P.R. China)

    International Nuclear Information System (INIS)

    Keyan, Zheng; Da-Lei, Ma; Changfang, Xie; Shangyao, Huang; Jianghua, Feng; Jingshu, Wu

    1982-01-01

    Isotopic studies of thermal and cold surface waters sampled in Beijing region have shown that the thermal waters are meteoric waters which have been precipitated in the mountainous area lying to the NW of Beijing. ΔD and over distances of more than 150 km in Sinian basement rocks which are 3 to 5 km in the SE sector of the region. Significant 18 O exchange with basement rocks occurs in the Jizhong Depression about 60 km to the SE of Beijing. On a smaller scale, a SE flow of thermal waters in basement rocks in corroborated by Δ 34 S data for the Beijing area and the Beijing geothermal field. The Beijing geothermal field and other geothermal fields in the SE sector of the Beijing region are an example for low temperature systems where the heat is derived from a normal or slightly greater than normal, terrestrial heat flow

  19. Computer codes for tasks in the fields of isotope and radiation research

    International Nuclear Information System (INIS)

    Friedrich, K.; Gebhardt, O.

    1978-11-01

    Concise descriptions of computer codes developed for solving problems in the fields of isotope and radiation research at the Zentralinstitut fuer Isotopen- und Strahlenforschung (ZfI) are compiled. In part two the structure of the ZfI program library MABIF is outlined and a complete list of all codes available is given

  20. The MSSM without gluinos; an effective field theory for the stop sector

    Energy Technology Data Exchange (ETDEWEB)

    Aebischer, Jason; Greub, Christoph [University of Bern, Albert Einstein Center for Fundamental Physics, Institute for Theoretical Physics, Bern (Switzerland); Crivellin, Andreas [Paul Scherrer Institut (PSI), Villigen (Switzerland); Yamada, Youichi [Tohoku University, Department of Physics, Sendai (Japan)

    2017-11-15

    In this article we study the MSSM with stops and Higgs scalars much lighter than gluinos and squarks of the first two generations. In this setup, one should use an effective field theory with partial supersymmetry in which the gluino and heavy squarks are integrated out in order to connect SUSY parameters (given at a high scale) to observables in the stop sector. In the construction of this effective theory, valid below the gluino mass scale, we take into account O(α{sub 3}) and O(Y{sub t,b}{sup 2}) effects and calculate the matching as well as the renormalization group evolution. As a result, the running of the parameters for the stop sector is modified with respect to the full MSSM and SUSY relations between parameters are broken. We show that for some couplings sizable numerical differences exist between the effective field theory approach and the naive calculation based on the MSSM running. (orig.)

  1. Isotope separation by ion waves

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1978-01-01

    One of the isotopes of an element having several isotopes can be separated from the others in a dense, neutral plasma. Thus initially a neutral plasma is prepared including the element in question. This may consist of positive ions and negative electrons or alternatively of positive and negative ions, or else of a mixture of positive ions, negative ions and electrons. The plasma may then be injected into a magnetic field or may be generated in the field where more energy is imparted to a selected isotope than to the others. Finally, the isotopes are separated from each other on the basis of their differential energies. For example, the selected isotope may be given more energy than the others by stimulating it within the plasma at its resonant frequency which may be close to the cyclotron frequency, either by an electric field or by a magnetic field. In order to excite the other isotope, a different resonant frequency is required which depends on the plasma density, the relative concentration of electrons if the plasma contains electrons, the strength of the magnetic field, the ratio of charge to mass of the isotope, and possibly on the physical parameters of the plasma apparatus itself, such as the ratio of the length of the plasma column to its radius. The more energetic isotope may be separated by energy dependent chemical reactions, it may be collected by a positively biased probe or else the isotopes may be separated from each other by magnetic fields or in various other ways

  2. Applications of stable Isotope ratios determinations in fruit juice authentication

    International Nuclear Information System (INIS)

    Magdas, Dana Alina; Dehelean, Adriana; Voica, Cezara; Puscas, Romulus

    2010-01-01

    Full text: Adulteration of a product consists in making it impure by fraudulent addition of a foreign or inferior substance. The result is either an alteration of the product and of its quality or a falsification. The falsification is a voluntary act with the intention of abuse. The falsification may be more or less sophisticated and its sophistication as well as its costs increases with the improvement of analytical methods. Vacuum concentration with aroma does not affect the chemical composition of fruit juices and therefore the determination of deuterium (D) and oxygen-18 content in waters is the most confident procedure for differentiating between a natural single strength juice and a juice rediluted from a concentrate. This technique is based on the fact that when absorbed by a plant, the rainwater or the irrigation water is fractionated by evapotranspiration, and enriched in the heavy isotopes (deuterium and oxygen-18) with respect to the light isotope (hydrogen and oxygen-16, respectively). It is known that climatic conditions affect the isotope content of rain waters and therefore that of fruit juices waters: the warmer climate, the higher the deuterium and oxygen-18 contents in water. Rainwater and tap water have nearly the same isotopic content and the water of fruit juices derived from concentrate by dilution with tap water has an isotopic content close to that of tap water. This makes it easy to distinguish diluted concentrates from the isotopically more enriched water of authentic single strength juice. In this study, single strength juice, in Romanian fruits, were investigated by mean of stable isotope measurements (oxygen, hydrogen and carbon) in order to offer a discussion basis for the authenticity of some fruit juices currently available on Romanian market. (authors)

  3. Deuterium dilution method for determining the Breast milk intake of babies

    International Nuclear Information System (INIS)

    Roohi, S.; Bilal, R.; Latif, Z.

    2000-11-01

    Various methods for measuring the milk intake of breast fed babies are available. Most methods are time consuming, cumbersome and inaccurate. The report describes various methods used for Breast Milk intake measurement with emphasis on the D/sub 2/O dilution method. The methodology of the D/sub 2/O dilution method is now streamlined in this Inst. for measuring the milk intake of babies. Advantages and disadvantages of all the methods used to determine the breast milk intake of the infants are also included in the present report. For the D/sub 2/O dilution method, and oral administration of small dose of deuterium oxide (sup 2/H/sup 2/O) is given to the mothers after collecting pre-dose samples. The post dose samples of urine from the baby and saliva from the mother are collected at 24 hours intervals over a 14 days period. These samples are analyzed on isotope ratio Mass spectrometer. The D/H values obtained over a 14 days period are then extrapolated to calculate the milk intake of babies using the Microsoft Excel Computer programme designed for this purpose. (author)

  4. Isotopic geochemistry at Wairakei

    International Nuclear Information System (INIS)

    Stewart, M.K.

    1985-12-01

    Deuterium measurements on geothermal water at Wairakei are consistent with the water being derived from rainfall which has percolated down from the surface. The oxygen-18 content, however, is enriched compared to average rainfall. This 18 O shift is due to isotopic exchange between water and rock at greater-than-explored depths. The magnitude of the shift implied that the mass ration (W/R) of water that has passed through the system (W) to the rock it has exchanged with (R) is about 1 assuming open (i.e. single-pass) conditions. (The ratio is about 2 if it has been a closed system, but this is thought to be less likely). The residence time of water underground cannot be determined from tritium and carbon-14 measurements at present, but arguments based on the argon isotope and deuterium contents suggest mean residence times of a few tens of thousand years. The water-rock ratio and large natural outflow of thermal water prior to exploitation are consistent with this. The 18 O content of the water has changed only slightly, and the D content not at all, during exploitation at Wairakei (measurements from 1963, 1974 and 1981). An initial tendency for the 18 O to increase because of steam loss (also shown more clearly by chloride), has been followed by decrease of 18 O (and chloride) because of dilution with infiltrating near-surface water in parts of the field

  5. Measurement of N2 fixation in Sesbania aculeata pers. and Sorghum bicolor L. grown in intercropping system, using sup 1 sup 5 N isotopic dilution technique. 1: Field evaluation under non-saline conditions

    International Nuclear Information System (INIS)

    Kurdali, F.; Khalifa, K.; Janat, M.

    2002-01-01

    A field experiment on Sesbania aculeata and Sorghum bicolor grown in mono cropping and in inter cropping systems was conducted under non-saline conditions (soil EC sub e 0.16, water EC sub w 1 ds/m/m) to evaluate dry matter production, total N yield, soil N uptake and N sub 2 -fixation using sup 1 sup 5 N isotope dilution method. Three different row ratios of sesbania (ses) and sorghum (sor) were subjected in the inter cropping system (2 ses: 1 sor; 1 ses: 1 sor and 1 ses: 2 sor row ratio). Dry matter yield of sole sorghum was higher than that of sole sesbania, and it was similar to that produced by the inter cropping treatments. However, total N yield of sole sorghum was significantly the lowest, with no differences being obtained between sole sesbania and inter cropping treatments. The LERs of total N yield were, in all cases, higher than 1, reflecting a greater advantage of inter cropping system in terms of land use efficiency. Percentages of N sub 2 fixation in the inter cropped sesbania were considerably enhanced compared with the pure stand of sesbania. This was mainly attributed to the depletion of soil N resulting from the greater apparent competitiveness of sorghum for soil N, and consequently, a greater dependence of sesbania on N sub 2 fixation. However, the degree of the intraspecific competition for soil N uptake was affected by the proportion of crops in the mixture, and it was considerably reduced in the 2 ses: 1 sor row ratio. This was demonstrated when an equal depletion of soil and fertilizer N uptake occurred for both crops. We excluded in all-inter cropping treatments the possibility of N transfer from sesbania to sorghum. Row inter cropping, with crops grown in alternation of two rows of sesbania with one row of sorghum, seemed to be the most adequate row ratio in terms of total N yield, LER, N sub 2 -fixation and soil N uptake balance of the component crops. (author)

  6. International Isotopes Markets

    Directory of Open Access Journals (Sweden)

    Stanislaw Z. Zhiznin

    2016-01-01

    Full Text Available The paper studies world markets of stable and radioactive isotopes. Isotopes have found various applications in science, industry, agriculture and other sectors of the economy, but especially - in medicine. Nuclear medicine is developing intensively all over the world thanks to the success in the treatment of various diseases with the help of radioactive pharmaceuticals (radiopharmaceuticals. The article uses empirical data from a forecast study of the global radiopharmaceuticals market made in 2015 by a research company «Markets and Markets» for the European, North American and global markets. The paper also analyzes the statistical data on the global export and import of natural uranium, enriched and depleted uranium, plutonium, thorium and some stable isotopes of non-medical purposes, presented by a company «Trend economy» in 2014. Despite a unique industrial base for the production of isotopes created in the Soviet Union Russia occupies a modest position on the world market of nuclear medicine except for certain areas. More than 80% of isotopes, produced in USSR were consumed domestically, the export of the stable and radioactive isotopes was in equal proportions. Now the country's domestic radiopharmaceuticals market is poorly developed. To radically change the situation, it is necessary to carry out reforms that stimulate the development of nuclear medicine.

  7. Isotope studies of UK tufa deposits and associated source waters

    International Nuclear Information System (INIS)

    Thorpe, P.M.

    1981-12-01

    Tufa is a secondary deposit of calcium carbonate precipitated from springs and streams. Previous attempts to date tufa deposits directly with 14 C have had limited success. The major problem is to quantify the amount of carbon incorporated in tufa, derived from the dissolution of carbonate bedrock, essentially free of 14 C. The isotopic composition of tufa-depositing streamwaters is similar to that of water recharging aquifers. The 14 C levels of recent tufa layers, at three sites, were similar to those of the source waters. 14 C dates from tufa at these sites suggested a Postglacial origin when corrected for bedrock carbon dilution of 16 to 24%. This dilution was overestimated by consideration of carbon mass balance using characteristic stable carbon isotope compositions (delta 13 C) for the biogenic and bedrock components. This method of correction is often applied to 14 C dates from groundwaters. The carbon isotope composition of spring waters supplying the tufa-depositing streams was realistically explained by a two stage process of carbonate dissolution under open and then closed conditions with respect to gaseous carbon dioxide. Seasonal variations in the 14 C and delta 13 C composition of stream and spring waters, downstream increases in 14 C and delta 13 C and seasonal variations in the oxygen and hydrogen isotopic composition of rainfall are explained. (author)

  8. Phase diagrams and switching of voltage and magnetic field in dilute magnetic semiconductor nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo, R. [Departamento de Matematica Aplicada y Ciencias de la Computacion, Universidad de Cantabria, 39005 Santander (Spain); Carretero, M.; Bonilla, L.L. [G. Millan Institute, Fluid Dynamics, Nanoscience and Industrial Maths., Universidad Carlos III de Madrid, 28911 Leganes (Spain); Unidad Asociada al Instituto de Ciencia de Materiales, CSIC, 28049 Cantoblanco, Madrid (Spain); Platero, G. [Instituto de Ciencia de Materiales, CSIC, 28049 Cantoblanco, Madrid (Spain)

    2010-04-15

    The response of an n-doped dc voltage biased II-VI multi-quantum well dilute magnetic semiconductor nanostructure having its first well doped with magnetic (Mn) impurities is analyzed by sweeping wide ranges of both the voltage and the Zeeman level splitting induced by an external magnetic field. The level splitting versus voltage phase diagram shows regions of stable self-sustained current oscillations immersed in a region of stable stationary states. Transitions between stationary states and self-sustained current oscillations are systematically analyzed by both voltage and level splitting abrupt switching. Sudden voltage or/and magnetic field changes may switch on current oscillations from an initial stationary state, and reciprocally, current oscillations may disappear after sudden changes of voltage or/and magnetic field changes into the stable stationary states region. The results show how to design such a device to operate as a spin injector and a spin oscillator by tuning the Zeeman splitting (through the applied external magnetic field), the applied voltage and the sample configuration parameters (doping density, barrier and well widths, etc.) to select the desired stationary or oscillatory behavior. Phase diagram of Zeeman level splitting {delta} vs. dimensionless applied voltage {phi} for N = 10 QWs. White region: stable stationary states; black: stable self-sustained current oscillations. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Lorentz Violation of the Photon Sector in Field Theory Models

    Directory of Open Access Journals (Sweden)

    Lingli Zhou

    2014-01-01

    Full Text Available We compare the Lorentz violation terms of the pure photon sector between two field theory models, namely, the minimal standard model extension (SME and the standard model supplement (SMS. From the requirement of the identity of the intersection for the two models, we find that the free photon sector of the SMS can be a subset of the photon sector of the minimal SME. We not only obtain some relations between the SME parameters but also get some constraints on the SMS parameters from the SME parameters. The CPT-odd coefficients (kAFα of the SME are predicted to be zero. There are 15 degrees of freedom in the Lorentz violation matrix Δαβ of free photons of the SMS related with the same number of degrees of freedom in the tensor coefficients (kFαβμν, which are independent from each other in the minimal SME but are interrelated in the intersection of the SMS and the minimal SME. With the related degrees of freedom, we obtain the conservative constraints (2σ on the elements of the photon Lorentz violation matrix. The detailed structure of the photon Lorentz violation matrix suggests some applications to the Lorentz violation experiments for photons.

  10. Stable isotope dilution assay (SIDA) and HS-SPME-GCMS quantification of key aroma volatiles for fruit and sap of Australian mango cultivars.

    Science.gov (United States)

    San, Anh T; Joyce, Daryl C; Hofman, Peter J; Macnish, Andrew J; Webb, Richard I; Matovic, Nicolas J; Williams, Craig M; De Voss, James J; Wong, Siew H; Smyth, Heather E

    2017-04-15

    Reported herein is a high throughput method to quantify in a single analysis the key volatiles that contribute to the aroma of commercially significant mango cultivars grown in Australia. The method constitutes stable isotope dilution analysis (SIDA) in conjunction with headspace (HS) solid-phase microextraction (SPME) coupled with gas-chromatography mass spectrometry (GCMS). Deuterium labelled analogues of the target analytes were either purchased commercially or synthesised for use as internal standards. Seven volatiles, hexanal, 3-carene, α-terpinene, p-cymene, limonene, α-terpinolene and ethyl octanoate, were targeted. The resulting calibration functions had determination coefficients (R 2 ) ranging from 0.93775 to 0.99741. High recovery efficiencies for spiked mango samples were also achieved. The method was applied to identify the key aroma volatile compounds produced by 'Kensington Pride' and 'B74' mango fruit and by 'Honey Gold' mango sap. This method represents a marked improvement over current methods for detecting and measuring concentrations of mango fruit and sap volatiles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A combined field and numerical approach to understanding dilute pyroclastic density current dynamics and hazard potential: Auckland Volcanic Field, New Zealand

    Science.gov (United States)

    Brand, Brittany D.; Gravley, Darren M.; Clarke, Amanda B.; Lindsay, Jan M.; Bloomberg, Simon H.; Agustin-Flores, Javier; Németh, Károly

    2014-04-01

    The most dangerous and deadly hazards associated with phreatomagmatic eruptions in the Auckland Volcanic Field (AVF; Auckland, New Zealand) are those related to volcanic base surges - dilute, ground-hugging, particle laden currents with dynamic pressures capable of severe to complete structural damage. We use the well-exposed base surge deposits of the Maungataketake tuff ring (Manukau coast, Auckland), to reconstruct flow dynamics and destructive potential of base surges produced during the eruption. The initial base surge(s) snapped trees up to 0.5 m in diameter near their base as far as 0.7-0.9 km from the vent. Beyond this distance the trees were encapsulated and buried by the surge in growth position. Using the tree diameter and yield strength of the wood we calculate that dynamic pressures (Pdyn) in excess of 12-35 kPa are necessary to cause the observed damage. Next we develop a quantitative model for flow of and sedimentation from a radially-spreading, dilute pyroclastic density currents (PDCs) to determine the damage potential of the base surges produced during the early phases of the eruption and explore the implications of this potential on future eruptions in the region. We find that initial conditions with velocities on the order of 65 m s- 1, bulk density of 38 kg m- 3 and initial, near-vent current thicknesses of 60 m reproduce the field-based Pdyn estimates and runout distances. A sensitivity analysis revealed that lower initial bulk densities result in shorter run-out distances, more rapid deceleration of the current and lower dynamic pressures. Initial velocity does not have a strong influence on run-out distance, although higher initial velocity and slope slightly decrease runout distance due to higher rates of atmospheric entrainment. Using this model we determine that for base surges with runout distances of up to 4 km, complete destruction can be expected within 0.5 km from the vent, moderate destruction can be expected up to 2 km, but much

  12. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    Science.gov (United States)

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  13. Polarization-preserving confocal microscope for optical experiments in a dilution refrigerator with high magnetic field.

    Science.gov (United States)

    Sladkov, Maksym; Bakker, M P; Chaubal, A U; Reuter, D; Wieck, A D; van der Wal, C H

    2011-04-01

    We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet, and which is a modular unit that can be easily swapped between use in a dilution refrigerator and other cryostats. We aimed at application in quantum optical experiments with electron spins in semiconductors and the design has been optimized for driving with and detection of optical fields with well-defined polarizations. This was implemented with optical access via a polarization maintaining fiber together with Voigt geometry at the cold finger, which circumvents Faraday rotations in the optical components in high magnetic fields. Our unit is versatile for use in experiments that measure photoluminescence, reflection, or transmission, as we demonstrate with a quantum optical experiment with an ensemble of donor-bound electrons in a thin GaAs film. © 2011 American Institute of Physics

  14. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues.

    Science.gov (United States)

    Devakumar, Delan; Grijalva-Eternod, Carlos S; Roberts, Sebastian; Chaube, Shiva Shankar; Saville, Naomi M; Manandhar, Dharma S; Costello, Anthony; Osrin, David; Wells, Jonathan C K

    2015-01-01

    Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1) To generate population specific calibration equations to predict lean mass (LM) from BIA in Nepalese children aged 7-9 years. (2) To explore methodological changes that may extend the range and improve accuracy. Methods. BIA measurements were obtained from 102 Nepalese children (52 girls) using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced. Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R (2) 93%). The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42). Reducing the number of children increased the error at the tails of the weight distribution. Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  15. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues

    Directory of Open Access Journals (Sweden)

    Delan Devakumar

    2015-03-01

    Full Text Available Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA is a simple and accurate method for estimating body composition, but requires population-specific calibration equations.Objectives. (1 To generate population specific calibration equations to predict lean mass (LM from BIA in Nepalese children aged 7–9 years. (2 To explore methodological changes that may extend the range and improve accuracy.Methods. BIA measurements were obtained from 102 Nepalese children (52 girls using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced.Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R2 93%. The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42. Reducing the number of children increased the error at the tails of the weight distribution.Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  16. Field dependence and anisotropy of the Meissner effect in sintered and dilute powders of YBa2Cu3O7

    International Nuclear Information System (INIS)

    Regnier, P.; Bontemps, N.; Monod, P.

    1990-01-01

    We report low temperature field-cooled susceptibility measurements on sintered and dilute YBa 2 Cu 3 O 7 powders in a 3-40 Oe field range. We find that the so-called Meissner fraction is field dependent, increasing as the field increases in ceramics and decreasing in powders. We also find a strong anisotropy, in both sets of samples: the Meissner fraction is larger when the field is applied parallel to the c axis. All these features are shown to emerge naturally if one assumes that the low temperature Meissner fraction: i) reflects the field dependence and the anisotropic properties of the equilibrium Meissner fraction which has been trapped at higher temperature. ii) is further reduced and its anisotropy is enhanced in sintered compounds with respect to powders, due to flux pinning at the grain boundaries

  17. Process and component for isotope separation

    International Nuclear Information System (INIS)

    Girodin, M.G.H.

    1974-01-01

    The description is given of a component for isotope separation by static centrifugation, the characteristic of which is that the gas, of single chemical composition, in other words without a diluting gas mixture, passes into a sonic collar then into a symmetrical supersonic diffuser where it acquires a uniform and rectilinear velocity above or very much above the speed of sound before going into its curved trajectory [fr

  18. Salinization and dilution history of ground water discharging into the Sea of Galilee, the Dead Sea Transform, Israel

    International Nuclear Information System (INIS)

    Bergelson, G.; Nativ, R.; Bein, A.

    1999-01-01

    The mechanism governing salinization of ground water discharging into the Sea of Galilee in Israel has been the subject of debate for several decades. Because the lake provides 25% of the water consumed annually in Israel, correct identification of the salt sources is essential for the establishment of suitable water-management strategies for the lake and the ground water in the surrounding aquifers. Existing salinization models were evaluated in light of available and newly acquired data including general chemistry, and O, H, C and Cl isotopes. Based on the chemical and isotopic observations, the proposed salt source is an ancient, intensively evaporated brine (21- to 33-fold seawater) which percolated through the valley formations from a lake which had formed in the Rift Valley following seawater intrusion during the late Miocene. Low Na:Cl and high Br:Cl values support the extensive evaporation, whereas high Ca:Cl and low Mg:Cl values indicate the impact of dolomitization of the carbonate host rock on the residual solution. Based on radiocarbon and other isotope data, the dilution of the original brine occurred in two stages: the first took place similar30andpuncsp; omitted000 a ago by slightly evaporated fresh-to-brackish lake water to form the Sea of Galilee Brine. The second dilution phase is associated with the current hydrological regime as the Sea of Galilee Brine migrates upward along the Rift faults and mixes with the actively circulating fresh ground water to form the saline springs. The spatially variable chemical and isotopic features of the saline springs suggest not only differential dilution by fresh meteoric water, but also differential percolation timing of the original brine into the tectonically disconnected blocks, registering different evaporation stages in the original brine. Consequently, various operations to reduce the brine contribution to the lake may be differentially effective in the various areas. (Copyright (c) 1999 Elsevier Science

  19. Concerns about Quadrupole ICP-MS Lead Isotopic Data and Interpretations in the Environment and Health Fields

    Directory of Open Access Journals (Sweden)

    Brian Gulson

    2018-04-01

    Full Text Available There has been a massive increase in recent years of the use of lead (Pb isotopes in attempts to better understand sources and pathways of Pb in the environment and in man or experimental animals. Unfortunately, there have been many cases where the quality of the isotopic data, especially that obtained by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS, are questionable, resulting in questionable identification of potential sources, which, in turn, impacts study interpretation and conclusions. We present several cases where the isotopic data have compromised interpretation because of the use of only the major isotopes 208Pb/206Pb and 207Pb/206Pb, or their graphing in other combinations. We also present some examples comparing high precision data from thermal ionization (TIMS or multi-collector plasma mass spectrometry (MC-ICP-MS to illustrate the deficiency in the Q-ICP-MS data. In addition, we present cases where Pb isotopic ratios measured on Q-ICP-MS are virtually impossible for terrestrial samples. We also evaluate the Pb isotopic data for rat studies, which had concluded that Pb isotopic fractionation occurs between different organs and suggest that this notion of biological fractionation of Pb as an explanation for isotopic differences is not valid. Overall, the brief review of these case studies shows that Q-ICP-MS as commonly practiced is not a suitable technique for precise and accurate Pb isotopic analysis in the environment and health fields.

  20. Concerns about Quadrupole ICP-MS Lead Isotopic Data and Interpretations in the Environment and Health Fields.

    Science.gov (United States)

    Gulson, Brian; Kamenov, George D; Manton, William; Rabinowitz, Michael

    2018-04-11

    There has been a massive increase in recent years of the use of lead (Pb) isotopes in attempts to better understand sources and pathways of Pb in the environment and in man or experimental animals. Unfortunately, there have been many cases where the quality of the isotopic data, especially that obtained by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS), are questionable, resulting in questionable identification of potential sources, which, in turn, impacts study interpretation and conclusions. We present several cases where the isotopic data have compromised interpretation because of the use of only the major isotopes 208 Pb/ 206 Pb and 207 Pb/ 206 Pb, or their graphing in other combinations. We also present some examples comparing high precision data from thermal ionization (TIMS) or multi-collector plasma mass spectrometry (MC-ICP-MS) to illustrate the deficiency in the Q-ICP-MS data. In addition, we present cases where Pb isotopic ratios measured on Q-ICP-MS are virtually impossible for terrestrial samples. We also evaluate the Pb isotopic data for rat studies, which had concluded that Pb isotopic fractionation occurs between different organs and suggest that this notion of biological fractionation of Pb as an explanation for isotopic differences is not valid. Overall, the brief review of these case studies shows that Q-ICP-MS as commonly practiced is not a suitable technique for precise and accurate Pb isotopic analysis in the environment and health fields.

  1. Profiles of Steroid Hormones in Canine X-Linked Muscular Dystrophy via Stable Isotope Dilution LC-MS/MS.

    Directory of Open Access Journals (Sweden)

    Helio A Martins-Júnior

    Full Text Available Golden retriever muscular dystrophy (GRMD provides the best animal model for characterizing the disease progress of the human disorder, Duchenne muscular dystrophy (DMD. The purpose of this study was to determine steroid hormone concentration profiles in healthy golden retriever dogs (control group - CtGR versus GRMD-gene carrier (CaGR and affected female dogs (AfCR. Therefore, a sensitive and specific analytical method was developed and validated to determine the estradiol, progesterone, cortisol, and testosterone levels in the canine serum by isotope dilution liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS. To more accurately understand the dynamic nature of the serum steroid profile, the fluctuating levels of these four steroid hormones over the estrous cycle were compared across the three experimental groups using a multivariate statistical analysis. The concentration profiles of estradiol, cortisol, progesterone, and testosterone revealed a characteristic pattern for each studied group at each specific estrous phase. Additionally, several important changes in the serum concentrations of cortisol and estradiol in the CaGR and AfCR groups seem to be correlated with the status and progression of the muscular dystrophy. A comprehensive and quantitative monitoring of steroid profiles throughout the estrous cycle of normal and GRMD dogs were achieved. Significant differences in these profiles were observed between GRMD and healthy animals, most notably for estradiol. These findings contribute to a better understanding of both dog reproduction and the muscular dystrophy pathology. Our data open new venues for hormonal behavior studies in dystrophinopathies and that may affect the quality of life of DMD patients.

  2. Determination of molybdenum in plant reference material by thermal-ionization isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Saumer, M.; Gantner, E.; Reinhardt, J.; Ache, H.J.

    1992-01-01

    An analytical method is described for the determination of the concentration and the isotopic composition of molybdenum in plant samples using thermal ionization mass spectrometry. After microwave acid digestion and liquid-liquid extractive separation with Amberlite LA-2, the molybdenum isotopes are measured as MoO 3 - -ions in a quadrupole mass spectrometer. In all cases, the relative standard deviation of the measurements of both natural and spike molybdenum was better than 3% for all ratios measured. The concentration of molybdenum found in three different plant reference materials agreed well with the certified values. (orig.)

  3. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  4. Detection of triclocarban and two co-contaminating chlorocarbanilides in US aquatic environments using isotope dilution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Sapkota, Amir; Heidler, Jochen; Halden, Rolf U

    2007-01-01

    The antimicrobial compound triclocarban (TCC; 3,4,4'-trichlorocarbanilide; CAS# 101-20-2) is a high-production-volume chemical, recently suggested to cause widespread contamination of US water resources. To test this hypothesis, we developed an isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry method for ultratrace analysis of TCC (0.9 ng/L detection limit) and analyzed low-volume water samples (200 mL) along with primary sludge samples from across the United States. All river water samples (100%) collected downstream of wastewater treatment plants had detectable levels of TCC, as compared to 56% of those taken upstream. Concentrations of TCC (mean+/-standard deviation) downstream of sewage treatment plants (84+/-110 ng/L) were significantly higher (P1219-99-4). In addition to TCC and DCC, municipal sludge contained a second co-contaminant, 3,3',4,4'-tetrachlorocarbanilide (TetraCC; CAS# 4300-43-0). Both newly detected compounds were present as impurities (0.2%(w/w) each) in technical grade TCC (99%). Application of the new method for chlorocarbanilide analysis yielded TCC occurrence data for 13 US states, confirmed the role of sewage treatment plants as environmental inputs of TCC, and identified DCC and TetraCC as previously unrecognized pollutants released into the environment alongside TCC.

  5. Quantitation of 5-Methyltetrahydrofolic Acid in Dried Blood Spots and Dried Plasma Spots by Stable Isotope Dilution Assays.

    Directory of Open Access Journals (Sweden)

    Markus Kopp

    Full Text Available Because of minimal data available on folate analysis in dried matrix spots (DMSs, we combined the advantages of stable isotope dilution assays followed by LC-MS/MS analysis with DMS sampling to develop a reliable method for the quantitation of plasma 5-methyltetrahydrofolic acid in dried blood spots (DBSs and dried plasma spots (DPSs as well as for the quantitation of whole blood 5-methyltetrahydrofolic acid in DBSs. We focused on two diagnostically conclusive parameters exhibited by the plasma and whole blood 5-methyltetrahydrofolic acid levels that reflect both temporary and long-term folate status. The method is performed using the [2H4]-labeled isotopologue of the vitamin as the internal standard, and three steps are required for the extraction procedure. Elution of the punched out matrix spots was performed using stabilization buffer including Triton X-100 in a standardized ultrasonication treatment followed by enzymatic digestion (whole blood only and solid-phase extraction with SAX cartridges. This method is sensitive enough to quantify 27 nmol/L whole blood 5-methyltetrahydrofolic acid in DBSs and 6.3 and 4.4 nmol/L plasma 5-methyltetrahydrofolic acid in DBSs and DPSs, respectively. The unprecedented accurate quantification of plasma 5-methyltetrahydrofolic acid in DBSs was achieved by thermal treatment prior to ultrasonication, inhibiting plasma conjugase activity. Mass screenings are more feasible and easier to facilitate for this method in terms of sample collection and storage compared with conventional clinical sampling for the assessment of folate status.

  6. Sensitized charge carrier injection into organic crystals studied by isotope effects in weak magnetic fields

    International Nuclear Information System (INIS)

    Bube, W.; Michel-Beyerle, M.E.; Haberkorn, R.; Steffens, E.

    1977-01-01

    The magnetic field (H approximately 50 Oe) dependence of the rhodamine sensitized triplet exciton density in anthracene crystals is influenced by isotopic substitution. This confirms the hyperfine interaction as mechanism explaining the change of the spin multiplicity in the initially formed singlet state of the radical pair. The isotope effect occurs in the sensitizing dye ( 14 N/ 15 N) rather than at the molecular site of the injected charge within the crystal. This can be understood in terms of the high hopping frequency of the charge carriers as compared to the time constant of the hyperfine induced singlet-triplet transition. Since the dye molecules adsorb in an oriented fashion, the angular dependence of the magnetic field modulation of the triplet exciton density can be interpreted without assuming any additional interactions. (Auth.)

  7. Rare isotopes and the sound of dilute nuclear matter

    Science.gov (United States)

    Papakonstantinou, P.

    2018-04-01

    Dilute baryonic matter, at densities below the normal saturation density of symmetric matter, is found on the crust of neutron stars and in collapsing supernova matter, its properties determining the evolution of those stellar objects. It is also readily found on the surface of ordinary and exotic atomic nuclei and lives fleetingly in the form of space-extended resonances of excited nucleons. Liminal states of nuclear matter, between saturation and full evaporation or clusterization, are manifest in the structure of symmetric nuclei through clustering and of very asymmetric rare species in haloes and the neutron skin; they stand literally at the threshold of a nucleus's response to hadronic probes, including processes which hinder or enable fusion. In this contribution I focus on excited states, and in particular exotic or not-so-exotic dipole excitation modes of N = Z nuclei and neutron-rich species, including new theoretical results on threshold strength. Modes of special interest are vibrations of and within diffuse surface layers and alpha-cluster oscillations. The modeling of such processes is relevant, directly or indirectly, for the description of reactions at astrophysical energies.

  8. High Resolution Gamma Ray Analysis of Medical Isotopes

    Science.gov (United States)

    Chillery, Thomas

    2015-10-01

    Compton-suppressed high-purity Germanium detectors at the University of Massachusetts Lowell have been used to study medical radioisotopes produced at Brookhaven Linac Isotope Producer (BLIP), in particular isotopes such as Pt-191 used for cancer therapy in patients. The ability to precisely analyze the concentrations of such radio-isotopes is essential for both production facilities such as Brookhaven and consumer hospitals across the U.S. Without accurate knowledge of the quantities and strengths of these isotopes, it is possible for doctors to administer incorrect dosages to patients, thus leading to undesired results. Samples have been produced at Brookhaven and shipped to UML, and the advanced electronics and data acquisition capabilities at UML have been used to extract peak areas in the gamma decay spectra. Levels of Pt isotopes in diluted samples have been quantified, and reaction cross-sections deduced from the irradiation parameters. These provide both cross checks with published work, as well as a rigorous quantitative framework with high quality state-of-the-art detection apparatus in use in the experimental nuclear physics community.

  9. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960)

    International Nuclear Information System (INIS)

    Bovard, P.; Candillon, C.

    1960-01-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [fr

  10. Preferential flow pathways revealed by field based stable isotope analysis of CO2 by mid-infrared laser spectroscopy

    Science.gov (United States)

    van Geldern, Robert; Nowak, Martin; Zimmer, Martin; Szizybalski, Alexandra; Myrttinen, Anssi; Barth, Johannes A. C.; Jost, Hj

    2016-04-01

    A newly developed and commercially available isotope ratio laser spectrometer for CO2 analyses has been tested during a 10-day field monitoring campaign at the Ketzin pilot site for CO2 storage in northern Germany. The laser instrument is based on tunable laser direct absorption in the mid-infrared. The instrument recorded a continuous 10-day carbon stable isotope data set with 30 minutes resolution directly on-site in a field-based laboratory container during a tracer experiment. To test the instruments performance and accuracy the monitoring campaign was accompanied by daily CO2 sampling for laboratory analyses with isotope ratio mass spectrometry (IRMS). The carbon stable isotope ratios measured by conventional IRMS technique and by the new mid-infrared laser spectrometer agree remarkably well within 2σ analytical precision (<0.3 ‰). This proves the capability of the new mid-infrared direct absorption technique to measure high precision and accurate real-time table isotope data directly in the field. The injected CO2 tracer had a distinct δ13C value that was largely different from the reservoir background value. The laser spectroscopy data revealed a prior to this study unknown, intensive dynamic with fast changing δ13C values. The arrival pattern of the tracer suggest that the observed fluctuations were probably caused by migration along separate and distinct preferential flow paths between injection well and observation well. The new technique might contribute to a better tracing of the migration of the underground CO2 plume and help to ensure the long-term integrity of the reservoir.

  11. Mercury dilution by autochthonous organic matter in a fertilized mangrove wetland.

    Science.gov (United States)

    Machado, Wilson; Sanders, Christian J; Santos, Isaac R; Sanders, Luciana M; Silva-Filho, Emmanoel V; Luiz-Silva, Wanilson

    2016-06-01

    A dated sediment core from a highly-fertilized mangrove wetland located in Cubatão (SE Brazil) presented a negative correlation between mercury (Hg) and organic carbon contents. This is an unusual result for a metal with well-known affinity to organic matter. A dilution of Hg concentrations by autochthonous organic matter explained this observation, as revealed by carbon stable isotopes signatures (δ(13)C). Mercury dilution by the predominant mangrove-derived organic matter counterbalanced the positive influences of algal-derived organic matter and clay contents on Hg levels, suggesting that deleterious effects of Hg may be attenuated. Considering the current paradigm on the positive effect of organic matter on Hg concentrations in coastal sediments and the expected increase in mangrove organic matter burial due to natural and anthropogenic stimulations of primary production, predictions on the influences of organic matter on Hg accumulation in mangrove wetlands deserve caution. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Isotopic characterization of targets for nuclear measurements at CBNM

    International Nuclear Information System (INIS)

    Bievre, P. de

    1985-01-01

    Nuclear measurements for which ''nuclear'' targets are prepared are almost always isotope-specific i.e. they are normally related to a particular nuclide in the target. The amount of this nuclide must be accurately assessed. There are essentially two ways to determine the number of atoms of this particular nuclide. (1) By determination of the amount of element, to which the nuclide belongs, on the target via classsical means; weighing substraction of impurities, calculation of element amount using known of the chemical compound in which the element is incorporated and, finally, measurement of the isotopic composition in order to determine the fraction of the nuclide concerned in the element. An alternative way may be to perform an elemental assay on the target followed by determination of the isotopic composition. (2) Another approach is isotope dilution mass spectrometry where a change in the isotopic composition of the ''target'' is induced by adding a known number of atoms (called ''spike'') of the element with a quite different composition. Measurement of the resulting change in isotopic composition yields directly the number of atoms of the nuclide under investigation. The method is highly selective, accurate and isotope-specific. (orig.)

  13. Measurement of the body composition of living gray seals by hydrogen isotope dilution

    International Nuclear Information System (INIS)

    Reilly, J.J.; Fedak, M.A.

    1990-01-01

    The body composition of living gray seals (Halichoerus grypus) can be accurately predicted from a two-step model that involves measurement of total body water (TBW) by 2 H or 3 H dilution and application of predictive relationships between body components and TBW that were derived empirically by slaughter chemical analysis. TBW was overestimated by both 2 HHO and 3 HHO dilution; mean overestimates were 2.8 +/- 0.9% (SE) with 2H and 4.0 +/- 0.6% with 3 H. The relationships for prediction of total body fat (TBF), protein (TBP), gross energy (TBGE), and ash (TBA) were as follows: %TBF = 105.1 - 1.47 (%TBW); %TBP = 0.42 (%TBW) - 4.75; TBGE (MJ) = 40.8 (mass in kg) - 48.5 (TBW in kg) - 0.4; and TBA (kg) = 0.1 - 0.008 (mass in kg) + 0.05 (TBW in kg). These relationships are applicable to gray seals of both sexes over a wide range of age and body conditions, and they predict the body composition of gray seals more accurately than the predictive equations derived from ringed seals (Pusa hispida) and from the equation of Pace and Rathbun, which has been reported to be generally applicable to mammals

  14. Tertiary Student Transitions: Sectors, Fields, Impacts of and Reasons for Study--Support Document

    Science.gov (United States)

    Fredman, Nick

    2012-01-01

    This paper examines the relationships between post-school educational fields and sectors and labour market considerations that appear to shape students' study decisions. It was found that pathways taken vary considerably by age, suggesting changes over time to patterns in tertiary education towards greater participation overall, a greater extent…

  15. 15N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    International Nuclear Information System (INIS)

    Ventura, Wilbur; Watanabe, Iwao

    1983-01-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the 15 N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. 15 N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower 15 N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N 2 fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the 15 N content of plants decreased in allowing the photodependent N 2 fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N 2 fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the 15 N dilution technique using the rice-covered soil as reference system. (Mori, K.)

  16. A comparative study on the skin penetration of pure tryptanthrin and tryptanthrin in Isatis tinctoria extract by dermal microdialysis coupled with isotope dilution ESI-LC-MS.

    Science.gov (United States)

    Oberthür, Christine; Heinemann, Christian; Elsner, Peter; Benfeldt, Eva; Hamburger, Matthias

    2003-05-01

    The indolo[2,1- b]quinazoline alkaloid tryptanthrin has recently been identified as a pharmacologically active compound in Isatis tinctoria, with potent dual inhibitory activity on prostaglandin and leukotriene synthesis. To investigate the skin penetration of tryptanthrin from solutions of pure compound and Isatis extracts, we developed and validated a cutaneous microdialysis model using ex vivo pig foreleg. Microdialysis was performed by placing linear probes in the dermis of the skin in situ, and tryptanthrin concentrations in the dialysates were determined by isotope dilution electrospray ionization LC-MS in the selected ion mode. Measurable concentrations of tryptanthrin were detected 30 min after application. A dose-dependent increase in tryptanthrin concentrations in the dialysate was observed for the Isatis extracts, but not for pure tryptanthrin. Microscopic analysis showed that the pure compound crystallized from the solution but remained in an amorphous state in the extracts.

  17. Basic research in homeopathy and ultra-high dilutions: what progress is being made?

    Science.gov (United States)

    Betti, Lucietta; Trebbi, Grazia; Olioso, Debora; Marzotto, Marta; Bellavite, Paolo

    2013-04-01

    This report summarises the latest research developments in the field of high dilutions and homeopathy, as presented at the GIRI symposium of the leading international organisation of scientists in this field, in Florence, Italy in September 2012. The scientific community's early scepticism concerning the possible biological and pharmacological activity of highly diluted solutions, is giving way to a more open-minded attitude that no longer obstructs critical and experimental investigations in this emerging field of biomedicine. Copyright © 2013. Published by Elsevier Ltd.. All rights reserved.

  18. Historical changes of the anthropogenic impact in a coastal lagoon: Pb isotopes and trace elements on mussel's fleshes and shells

    International Nuclear Information System (INIS)

    Labonne, M.; Othman, D.B.; Luck, J.M.

    1997-01-01

    Molluscs are known to concentrate metals and are used as bioindicators in many programs of coastal survey. The aims of this study were: (1) to better understand the spatial and temporal variations of metals in a greatly anthropized lagoon (Thau, S France) by using concentrations and Pb isotopes in mussel flesh; (2) to compare present and past environment and the different sources of local Pb in recent mussel shells and ones from the Roman empire. Young mussels (Mytilus galloprovincialis) from the sea were introduced at various locations in the lagoon. The ancient shells came from a Roman villa on the lagoon coast. We compare their isotopic compositions to different sources present on the watershed such as rocks, road, harbour, ancient lead castings or Spanish and English ingots. Concentrations of trace metals were determined directly by ICP-MS after proper dilution and the isotopic compositions was determined on a VG Sector mass spectrometer. The Pb concentration variations are difficult to separate from weight variations so we use isotopic compositions for determination of lead sources. The Pb isotopic composition of the flesh define nice alignments in 207 Pb/ 204 Pb vs 206 Pb/ 204 Pb diagram with season, which can be explained by two-component mixtures. However, while one end-member remains quite stable and influenced by road network, the other one shifts to more radiogenic values indicating either a variable origin, or varying proportions of a third component. The ancient shells have more radiogenic isotopes than the current shells but shift towards ancient lead castings and ingots signature. Variations of Pb ratios in the ancient shells can be roughly correlated with age and the evolution of population density around the lagoon over the centuries

  19. Magnetic hyperfine field at a Cd impurity diluted in RCo{sub 2} at finite temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, A.L. de, E-mail: alexandre.oliveira@ifrj.edu.br [Instituto Federal de Educação, Ciência e Tecnologia do Rio de Janeiro, Campus Nilópolis – RJ (Brazil); Chaves, C.M., E-mail: cmch@cbpf.br [Centro Brasileiro de Pesquisas Físicas, Rio de Janeiro (Brazil); Oliveira, N.A. de [Instituto de Física Armando Dias Tavares, Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil); Troper, A. [Centro Brasileiro de Pesquisas Físicas, Rio de Janeiro (Brazil)

    2015-06-15

    The local magnetic moments and the magnetic hyperfine fields at an s–p Cd impurity diluted in inter-metallic Laves phase compounds RCo{sub 2} (R=Gd, Tb) at finite temperatures are calculated. For other rare earth elements (light or heavy) the pure compounds display a magnetic first order transition and are not describable by our formalism. The host has two coupled lattices (R and Co) both having itinerant d electrons but only the rare earth lattice has localized f electrons. They all contribute to the magnetization of the host and also to the local moment and to the magnetic hyperfine field at the impurity. The investigation of magnetic hyperfine field in these materials then provides valuable information on the d-itinerant electrons and also on the localized (4f) magnetic moments. For the d–d electronic interaction we use the Hubbard–Stratonovich identity thus allowing the employment of functional integral in the static saddle point approximation. Our model reproduces quite well the experimental data. - Highlights: • A functional integral method in the static limit, producing site disorder, is used. • The site disorder is treated with the coherent potential approximation (CPA) • A Friedel sum rule gives a self-consistency condition for the impurity energy. • The experimental curve of hyperfine fields×temperature is very well reproduced.

  20. Does the Rayleigh equation apply to evaluate field isotope data in contaminant hydrogeology?

    Science.gov (United States)

    Abe, Yumiko; Hunkeler, Daniel

    2006-03-01

    Stable isotope data have been increasingly used to assess in situ biodegradation of organic contaminants in groundwater. The data are usually evaluated using the Rayleigh equation to evaluate whether isotope data follow a Rayleigh trend, to calculate the extent of contaminant biodegradation, or to estimate first-order rate constants. However, the Rayleigh equation was developed for homogeneous systems while in the subsurface, contaminants can migrate at different velocities due to physical heterogeneity. This paper presents a method to quantify the systematic effect that is introduced by applying the Rayleigh equation to field isotope data. For this purpose, the travel time distribution between source and sampling point is characterized by an analytical solution to the advection-dispersion equation. The systematic effect was evaluated as a function of the magnitude of physical heterogeneity, geometry of the contaminant plume, and degree of biodegradation. Results revealed that the systematic effect always leads to an underestimation of the actual values of isotope enrichment factors, the extent of biodegradation, or first-order rate constants, especially in the dispersion-dominant region representing a higher degree of physical heterogeneity. A substantial systematic effect occurs especially for the quantification of first-order rate constants (up to 50% underestimation of actual rate) while it is relatively small for quantification of the extent of biodegradation (< 5% underestimation of actual degree of biodegradation). The magnitude of the systematic effect is in the same range as the uncertainty due to uncertainty of the analytical data, of the isotope enrichment factor, and the average travel time.

  1. Selection of mode for the measurement of lead isotope ratios by inductively coupled plasma mass spectrometry and its application to milk powder analysis

    International Nuclear Information System (INIS)

    Dean, J.R.; Ebdon, L.; Massey, R.

    1987-01-01

    An investigation into the selection of the optimum mode for the measurement of isotope ratios in inductively coupled plasma mass spectrometry (ICP-MS) is reported, with particular reference to lead isotope ratios. Variation in the accuracy and precision achievable using the measurement modes of scanning and peak jumping are discussed. It is concluded that if sufficient sample and time are available, scanning gives best accuracy and precision. Isotope dilution analysis (IDA) has been applied to the measurement of the lead content of two dried milk powders of Australian and European origin introduced as slurries into ICP-MS. Differences in the lead isotope ratios in the two milk powders were investigated and the total lead content determined by IDA. Isotope dilution analysis permitted accurate data to be obtained with an RSD of 4.2% or milk powder containing less than 30 ng g -1 of lead. The ICP-MS technique is confirmed as a useful tool for IDA. (author)

  2. Stable Isotope Group 1982 progress report

    International Nuclear Information System (INIS)

    Stewart, M.K.

    1983-06-01

    The work of the Stable Isotope Group of the Institute of Nuclear Sciences during 1982, in the fields of isotope geology, isotope hydrology, geochronology, isotope biology and mass spectrometer instrumentation, is described

  3. Use of isotopes for increasing biological nitrogen fixation and yield of pastures

    International Nuclear Information System (INIS)

    Yao Yunyin

    1992-05-01

    The N-15 natural abundance and N-15 isotope dilution (ID) methods for measuring dinitrogen fixation and nitrogen transfer in alfalfa and alfalfa intercropped with meadow fescue were compared in three experiments. Although both methods gave essentially the same estimates the precision of the values obtained differed, and values obtained by the isotope dilution method were more precise. Similarly, the N-15 natural abundance method was not very suitable for detecting N transfer from legume to non-legume. Greater amounts of N transfer were detected by the ID method, and with a greater precision. Mixed cropping sometimes gave slight to high increases in % nitrogen fixation compared to alfalfa cropped alone. On the whole alfalfa was found to be a high nitrogen fixer, with fixation values from the second harvest onwards almost always greater than 80% and often close to 100%. 23 refs, 30 tabs

  4. Radioisotope dilution analyses of geological samples using 236U and 229Th

    International Nuclear Information System (INIS)

    Rosholt, J.N.

    1984-01-01

    The use of 236 U and 229 Th in alpha spectrometric measurements has some advantages over the use of other tracers and measurement techniques in isotope dilution analyses of most geological samples. The advantages are: 1) these isotopes do not occur in terrestrial rocks, 2) they have negligible decay losses because of their long half lives, 3) they cause minimal recoil contamination to surface-barrier detectors, 4) they allow for simultaneous determination of the concentration and isotopic composition of uranium and thorium in a variety of sample types, and 5) they allow for simple and constant corrections for spectral interferences, 0.5% of the 238 U activity is subtracted for the contribution of 235 U in the 236 U peak and 1% of the 229 Th activity is subtracted from the 230 Th activity. Disadvantages in using 236 U and 229 Th are: 1) individual separates of uranium and thorium must be prepared as very thin sources for alpha spectrometry, 2) good resolution in the spectrometer system is required for thorium isotopic measurements where measurement times may extend to 300 h, and 3) separate calibrations of the 236 U and 229 Th spike solution with both uranium and thorium standards are required. The use of these tracers in applications of uranium-series disequilibrium studies has simplified the measurements required for the determination of the isotopic composition of uranium and thorium because of the minimal corrections needed for alpha spectral interferences. (orig.)

  5. Radioisotope dilution analyses of geological samples using 236U and 229Th

    Science.gov (United States)

    Rosholt, J.N.

    1984-01-01

    The use of 236U and 229Th in alpha spectrometric measurements has some advantages over the use of other tracers and measurement techniques in isotope dilution analyses of most geological samples. The advantages are: (1) these isotopes do not occur in terrestrial rocks, (2) they have negligible decay losses because of their long half lives, (3) they cause minimal recoil contamination to surface-barrier detectors, (4) they allow for simultaneous determination of the concentration and isotopic composition of uranium and thorium in a variety of sample types, and (5) they allow for simple and constant corrections for spectral inferences, 0.5% of the 238U activity is subtracted for the contribution of 235U in the 236U peak and 1% of the 229Th activity is subtracted from the 230Th activity. Disadvantages in using 236U and 229Th are: (1) individual separates of uranium and thorium must be prepared as very thin sources for alpha spectrometry, (2) good resolution in the spectrometer system is required for thorium isotopic measurements where measurement times may extend to 300 h, and (3) separate calibrations of the 236U and 229Th spike solution with both uranium and thorium standards are required. The use of these tracers in applications of uranium-series disequilibrium studies has simplified the measurements required for the determination of the isotopic composition of uranium and thorium because of the minimal corrections needed for alpha spectral interferences. ?? 1984.

  6. Cooperation of CMEA member states in the field of the manufacture and use of stable isotopes and compounds thus labelled

    International Nuclear Information System (INIS)

    Ertel, G.; Ewald, G.

    1977-01-01

    The contribution presents a survey of scientific-technical cooperation of CMEA member states in the field of stable isotopes, it deals with the specialization of stable isotope production and compounds thus labelled, and gives the prospects for further development of this cooperation. (HK) [de

  7. Application of Environmental Isotopes in Hydrological Studies Along the River Nile Valley, Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Nada, A. A. [Site and Environmental Dept. NCNSRC, Atomic Energy Authority, Cairo (Egypt)

    2013-07-15

    This paper reviews some of the contributions of isotope techniques to better understanding hydrological problems in Egypt and the Nile basin. The stable isotope composition of precipitation shows considerable variations both in time and space since it is controlled by climatic factors. Surface waters became enriched in deuterium and oxygen-18 relative to their initial isotopic composition as losses by evaporation occur. The GNIP sampling stations at Entebbe and Addis Ababa, which are located at the source of the Nile River, present relatively depleted isotopic contents. Assuming that the central Africa runoff (White Nile downstream from Sudan) represents 30% of the natural discharge of Egypt, and the remaining 70% is derived from Ethiopia (Blue Nile), we obtain a composite depleted stable isotope composition of the river Nile reaching upper Egypt under natural conditions (before the construction of the Aswan High Dam). Stable isotopes were used to estimate the evaporation rate from Lake Nasser, based on the isotopic content of the lake water. The lake can be divided into two sectors: the first sector, with remarkable vertical gradient in O-18 and deuterium, and a second sector, characterized by a lower vertical isotopic gradient. In order to detect this effect, surface Nile water samples have been collected at Cairo after a heavy storm event covering all Egypt at the beginning of November 1994, characterized by very negative deuterium and oxygen-18 contents. The isotopic content of Nile water samples fluctuated and slightly changed with time. The variation of the bomb tritium response of the Nile has been reconstructed using a model based on the contents in the catchment areas of the Nile. Pre-bomb tritium content in the Nile was about 5 TU, reaching a maximum level during the early sixties of about 500 TU. At present the tritium level content of the Nile is about 6 TU. (author)

  8. Isotope Production and Distribution Program`s Fiscal Year 1997 financial statement audit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-27

    The Department of Energy Isotope Production and Distribution Program mission is to serve the national need for a reliable supply of isotope products and services for medicine, industry and research. The program produces and sells hundreds of stable and radioactive isotopes that are widely utilized by domestic and international customers. Isotopes are produced only where there is no U.S. private sector capability or other production capacity is insufficient to meet U.S. needs. The Department encourages private sector investment in new isotope production ventures and will sell or lease its existing facilities and inventories for commercial purposes. The Isotope Program reports to the Director of the Office of Nuclear Energy, Science and Technology. The Isotope Program operates under a revolving fund established by the Fiscal Year (FY) 1990 Energy and Water Appropriations Act and maintains financial viability by earning revenues from the sale of isotopes and services and through annual appropriations. The FY 1995 Energy and Water Appropriations Act modified predecessor acts to allow prices charged for Isotope Program products and services to be based on production costs, market value, the needs of the research community, and other factors. Although the Isotope Program functions as a business, prices set for small-volume, high-cost isotopes that are needed for research purposes may not achieve full-cost recovery. As a result, isotopes produced by the Isotope Program for research and development are priced to provide a reasonable return to the U.S. Government without discouraging their use. Commercial isotopes are sold on a cost-recovery basis. Because of its pricing structure, when selecting isotopes for production, the Isotope Program must constantly balance current isotope demand, market conditions, and societal benefits with its determination to operate at the lowest possible cost to U.S. taxpayers. Thus, this report provides a financial analysis of this situation.

  9. Isotope dilution mass spectrometry: What can it contribute to accuracy in trace analysis?

    International Nuclear Information System (INIS)

    Bievre, P. de

    1990-01-01

    IDMS uses the fact that the isotopes are much better 'representatives' of an element than the average chemical atom and their numbers can be measured better in a more physical measurement than in a classicial chemical measurement where atoms are involved. (orig./EF)

  10. Sectoral Innovation Watch Biotechnology Sector. Final sector report

    NARCIS (Netherlands)

    Enzing, C.

    2011-01-01

    Biotechnology has evolved from a single set of technologies in the mid 1970s into a full grown technological field that is the driving force in innovation processes in many industrial sectors (pharmaceutical, medical, agriculture, food, chemical, environment, instruments). Nowadays, biotechnology is

  11. Exchange bias in diluted-antiferromagnet/antiferromagnet bilayers

    International Nuclear Information System (INIS)

    Mao, Zhongquan; Zhan, Xiaozhi; Chen, Xi

    2015-01-01

    The hysteresis-loop properties of a diluted-antiferromagnetic (DAF) layer exchange coupling to an antiferromagnetic (AF) layer are investigated by means of numerical simulations. Remarkable loop shift and coercivity enhancement are observed in such DAF/AF bilayers, while they are absent in the uncoupled DAF single layer. The influences of pinned domains, dilution, cooling field and DAF layer thickness on the loop shift are investigated systematically. The result unambiguously confirms an exchange bias (EB) effect in the DAF/AF bilayers. It also reveals that the EB effect originates from the pinned AF domains within the DAF layer. In contrast to conventional EB systems, frozen uncompensated spins are not found at the interface of the AF pinning layer. (paper)

  12. Certification of methylmercury in cod fish tissue certified reference material by species-specific isotope dilution mass spectrometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Kazumi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Yarita, Takashi; Takatsu, Akiko; Okamoto, Kensaku; Chiba, Koichi [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Environmental Standard Section, Tsukuba, Ibaraki (Japan)

    2008-07-15

    A new cod fish tissue certified reference material, NMIJ CRM 7402-a, for methylmercury analysis was certified by the National Metrological Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Cod fish was collected from the sea close to Japan. The cod muscle was powdered by freeze-pulverization and was placed into 600 glass bottles (10 g each), which were sterilized with {gamma}-ray irradiation. The certification was carried out using species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID-GC-ICPMS), where {sup 202}Hg-enriched methylmercury (MeHg) was used as the spike compound. In order to avoid any possible analytical biases caused by nonquantitative extraction, degradation and/or formation of MeHg in sample preparations, two different extraction methods (KOH/methanol and HCl/methanol extractions) were performed, and one of these extraction methods utilized two different derivatization methods (ethylation and phenylation). A double ID method was adopted to minimize the uncertainty arising from the analyses. In order to ensure not only the reliability of the analytical results but also traceability to SI units, the standard solution of MeHg used for the reverse-ID was prepared from high-purity MeHg chloride and was carefully assayed as follows: the total mercury was determined by ID-ICPMS following aqua regia digestion, and the ratio of Hg as MeHg to the total Hg content was estimated by GC-ICPMS. The certified value given for MeHg is 0.58 {+-} 0.02 mg kg{sup -1} as Hg. (orig.)

  13. Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Le-Minh, Nhat; Stuetz, Richard M; Khan, Stuart J

    2012-01-30

    A highly sensitive method for the analysis of six sulfonamide antibiotics (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine and sulfamethoxazole), two sulfonamide metabolites (N(4)-acetyl sulfamethazine and N(4)-acetyl sulfamethoxazole) and the commonly co-applied antibiotic trimethoprim was developed for the analysis of complex wastewater samples. The method involves solid phase extraction of filtered wastewater samples followed by liquid chromatography-tandem mass spectral detection. Method detection limits were shown to be matrix-dependent but ranged between 0.2 and 0.4 ng/mL for ultrapure water, 0.4 and 0.7 ng/mL for tap water, 1.4 and 5.9 ng/mL for a laboratory-scale membrane bioreactor (MBR) mixed liquor, 0.7 and 1.7 ng/mL for biologically treated effluent and 0.5 and 1.5 ng/g dry weight for MBR activated sludge. An investigation of analytical matrix effects was undertaken, demonstrating the significant and largely unpredictable nature of signal suppression observed for variably complex matrices compared to an ultrapure water matrix. The results demonstrate the importance of accounting for such matrix effects for accurate quantitation, as done in the presented method by isotope dilution. Comprehensive validation of calibration linearity, reproducibility, extraction recovery, limits of detection and quantification are also presented. Finally, wastewater samples from a variety of treatment stages in a full-scale wastewater treatment plant were analysed to illustrate the effectiveness of the method. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. /sup 15/N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    Energy Technology Data Exchange (ETDEWEB)

    Ventura, W; Watanabe, Iwao [International Rice Research Inst., College, Laguna (Phillippines)

    1983-06-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the /sup 15/N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. /sup 15/N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower /sup 15/N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N/sub 2/ fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the /sup 15/N content of plants decreased in allowing the photodependent N/sub 2/ fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N/sub 2/ fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the /sup 15/N dilution technique using the rice-covered soil as reference system.

  15. The role and activity of the IAEA in the field of isotope use

    International Nuclear Information System (INIS)

    Kakihana, H.

    1980-01-01

    The Regional Cooperative Agreement (RCA) in Asia by IAEA entered into force in June, 1972, based on the period of every 5 years with the participation of Australia, India, Indonesia, Japan, Republic of Korea, Malaysia, Pakistan, Phillippine, Singapore and Thailand. The RCA aims to direct its technological efforts of using isotopes and radiation to the areas of highest regional interests, i.e. food and agriculture, health care, water resource management, environmental control and industrial development, along with upgrading the infrastructure to keep pace with technological advancements. The activities of the RCA in these fields are described as follows: food processing with ionizing radiation and the improvement of protein supplies, environment, hydrology and sedimentology, neutron scattering and nuclear instrument maintenance, UNDP regional project for industrial isotope and radiation applications. (J.P.N.)

  16. Dilution and volatilization of groundwater contaminant discharges in streams

    DEFF Research Database (Denmark)

    Aisopou, Angeliki; Bjerg, Poul Løgstrup; Sonne, Anne Thobo

    2015-01-01

    measurement. The solution was successfully applied to published field data obtained in a large and a small Danish stream and provided valuable information on the risk posed by the groundwater contaminant plumes. The results provided by the dilution and volatilization model are very different to those obtained......An analytical solution to describe dilution and volatilization of a continuous groundwater contaminant plume into streams is developed for risk assessment. The location of groundwater plume discharge into the stream (discharge through the side versus bottom of the stream) and different...

  17. Method and device for isotope separation

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1976-01-01

    The method works with a converted Q machine. The plasma containing the isotopes to be separated is crossed by a magnetic field running in the direction of the plasma column. More energy is transfered to the chosen isotope by oscillating magnetic and/or electric fields or by sound waves by using the specific resonance frequency for the selected isotope. The isotopes thus heated to different extents can be separated according to various methods given in the patent claims. (GG) [de

  18. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1983-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure, particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  19. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1981-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure , particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  20. Determination of thyroid hormones in placenta using isotope-dilution liquid chromatography quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Li, Zhong-Min; Giesert, Florian; Vogt-Weisenhorn, Daniela; Main, Katharina Maria; Skakkebæk, Niels Erik; Kiviranta, Hannu; Toppari, Jorma; Feldt-Rasmussen, Ulla; Shen, Heqing; Schramm, Karl-Werner; De Angelis, Meri

    2018-01-26

    The transplacental passage of thyroid hormones (THs) is of great significance since the maternal THs are vitally important in ensuring the normal fetal development. In this paper, we determined the concentrations of seven THs, viz. L-thyroxine (T 4 ), 3,3',5-triiodo-l-thyronine (T 3 ), 3,3',5'-triiodo-l-thyronine (rT 3 ), 3,3'-diiodo-l-thyronine (T 2 ), 3,5-diiodo-l-thyronine (rT 2 ), 3-iodo-l-thyronine (T 1 ) and 3-iodothyronamine (T 1 AM), in placenta using isotope dilution liquid chromatography quadrupole time-of-flight mass spectrometry. We optimized the method using isotopically labeled quantification standards ( 13 C 6 -T 4 , 13 C 6 -T 3 , 13 C 6 -rT 3 and 13 C 6 -T 2 ) and recovery standard ( 13 C 12 -T 4 ) in combination with solid-liquid extraction, liquid-liquid extraction and solid phase extraction. The linearity was obtained in the range of 0.5-150 pg uL -1 with R 2 values >0.99. The method detection limits (MDLs) ranged from 0.01 ng g -1 to 0.2 ng g -1 , while the method quantification limits (MQLs) were between 0.04 ng g -1 and 0.7 ng g -1 . The spike-recoveries for THs (except for T 1 and T 1 AM) were in the range of 81.0%-112%, with a coefficient of variation (CV) of 0.5-6.2%. The intra-day CVs and inter-day CVs were 0.5%-10.3% and 1.19%-8.88%, respectively. Concentrations of the THs were 22.9-35.0 ng g -1  T 4 , 0.32-0.46 ng g -1  T 3 , 2.86-3.69 ng g -1 rT 3 , 0.16-0.26 ng g -1  T 2 , and < MDL for other THs in five human placentas, and 2.05-3.51 ng g -1  T 4 , 0.37-0.62 ng g -1  T 3 , 0.96-1.3 ng g -1 rT 3 , 0.07-0.13 ng g -1  T 2 and < MDL for other THs in five mouse placentas. The presence of T 2 was tracked in placenta for the first time. This method with improved selectivity and sensitivity allows comprehensive evaluation of TH homeostasis in research of metabolism and effects of environmental contaminant exposures. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Molecular analysis of two mouse dilute locus deletion mutations: Spontaneous dilute lethal20J and radiation-induced dilute prenatal lethal Aa2 alleles

    International Nuclear Information System (INIS)

    Strobel, M.C.; Seperack, P.K.; Copeland, N.G.; Jenkins, N.A.

    1990-01-01

    The dilute (d) coat color locus of mouse chromosome 9 has been identified by more than 200 spontaneous and mutagen-induced recessive mutations. With the advent of molecular probes for this locus, the molecular lesion associated with different dilute alleles can be recognized and precisely defined. In this study, two dilute mutations, dilute-lethal20J (dl20J) and dilute prenatal lethal Aa2, have been examined. Using a dilute locus genomic probe in Southern blot analysis, we detected unique restriction fragments in dl20J and Aa2 DNA. Subsequent analysis of these fragments showed that they represented deletion breakpoint fusion fragments. DNA sequence analysis of each mutation-associated deletion breakpoint fusion fragment suggests that both genomic deletions were generated by nonhomologous recombination events. The spontaneous dl20J mutation is caused by an interstitial deletion that removes a single coding exon of the dilute gene. The correlation between this discrete deletion and the expression of all dilute-associated phenotypes in dl20J homozygotes defines the dl20J mutation as a functional null allele of the dilute gene. The radiation-induced Aa2 allele is a multilocus deletion that, by complementation analysis, affects both the dilute locus and the proximal prenatal lethal-3 (pl-3) functional unit. Molecular analysis of the Aa2 deletion breakpoint fusion fragment has provided access to a previously undefined gene proximal to d. Initial characterization of this new gene suggests that it may represent the genetically defined pl-3 functional unit

  2. Oxygen isotope studies of the Salton Sea geothermal field

    International Nuclear Information System (INIS)

    Olson, E.R.

    1978-01-01

    Interbedded shales and sandstones were drilled to a depth of 1588 metres in Sinclair Number Four Well, Salton Sea Geothermal Field. Bottom hole temperatures are approximately 290 0 C. The oxygen dels of hydrothermal and detrital calcite have a systematic relationship at any depth in the geothermal reservoir. Typical values are: vein calcite, +6 0 / 00 ; calcite in white sandstone, +10 0 / 00 ; calcite in dark gray shale, +11 0 / 00 ; calcite in light gray shale, +17 0 / 00 ; calcite in red-brown shale, +20 0 / 00 . This succession represents decreasing water-rock interaction that is also indicated by the clay mineralogy of the shales. Permeability has a marked effect on the equilibration of water and rocks at any given temperature. Original differences in permeability have resulted in partial preservation of original detrital sedimentary compositions. The fluids in the Salton Sea Geothermal Field are probabaly partially evaporated Colorado River water, and their oxygen del values vary as much as 4 0 / 00 throughout the field. Truesdell's (1974) data suggest that dissolved salts may make the water oxygen activity del as much as 6 0 / 00 greater than the concentration del in the geothermal reservoir. Such an uncertainty is a serious impediment to precise isotope geothermometry in this system.(auth.)

  3. Atmospheric dilution factors for radioactive releases from Inshas research reactor, Egypt

    International Nuclear Information System (INIS)

    Abdel Aal, M.M.; Aly, A.I.M.; Tawfik, F.S.

    1994-01-01

    In the frame of assessing the suitability of Inshas site for constructing a new research reactor 20 MW, the meteorological condition are analyzed to determine the most affected population sectors. The atmospheric stability classes are estimated by a developed computer program in which the meteorological data for one year are used as input data. The results indicate that stability class F (moderately stable) is predominant one. The dilution factor is calculated using the computer code XOQDOQ for meteorological evaluation of routine effluent releases at nuclear power stations, which implements regulatory Guide 1.111 for both normal and desert conditions and for ground and elevated releases. The concentration isopleths are plotted and the most affected sector is the southern one with higher values for desert condition than the corresponding normal condition at same distance from the source. 4 fig., 3 tab

  4. Measurement of N2 fixation in Sesbania aculeata and Sorghum bicolor L. grown in intercropping system using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Khalifa, K.; Janat, M.

    2001-09-01

    A field experiment on Sesbania aculeata and Sorghum bicolor grown in mono cropping and in inter cropping systems was conducted under non-saline conditions (soil EC e 0.16, water EC w 1dS/m) to evaluate dry matter production, total N yield, soil N uptake and N 2 -fixation using 15 N isotope dilution method. Three different row ratios of sesbania (ses) and sorghum (sor) were subjected in the inter cropping system (2ses: 1sot; 1ses: 1sor and 1ses: 2sor row ratio). Dry matter yield of sole sorghum was higher than that of sole sesbania, and it was similar to that produced by the inter cropping treatments. However, total N yield of sole sorghum was significantly the lowest, with no differences being obtained between sole sesbania and inter cropping treatments. The LERs of total N yield were, in all cases, higher than 1, reflecting a greater advantage of inter cropping system in terms of land use efficiency. Percentages of N 2 fixation in the inter cropped sesbania were considerably enhanced compared with the pure stand of sesbania. This was mainly attributed to the depletion of soil N resulting from the greater apparent competitiveness of sorghum for soil N, and consequently, a greater dependence of sesbania on N 2 fixation. However, the degree of the intraspecific competition for soil N uptake was affected by the proportion of crops in the mixture, and it was considerably reduced in the 2ses: 1sor row ratio. This was demonstrated when an equal depletion of soil and fertilizer N uptake occurred for both crops. We excluded in all-inter cropping treatments the possibility of N transfer from sesbania to sorghum. Row inter cropping, with crops grown in alternation of two rows of sesbania with one row of sorghum, seemed to be the most adequate row ratio in terms of total N yield, LER, N 2 -fixation and soil N uptake balance of the component crops. (author)

  5. Simple and accurate measurement of carbamazepine in surface water by use of porous membrane-protected micro-solid-phase extraction coupled with isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Hui Ling [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); Wong, Lingkai [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Liu, Qinde, E-mail: liu_qinde@hsa.gov.sg [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Teo, Tang Lin; Lee, Tong Kooi [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Lee, Hian Kee, E-mail: chmleehk@nus.edu.sg [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore)

    2016-03-17

    To achieve fast and accurate analysis of carbamazepine in surface water, we developed a novel porous membrane-protected micro-solid-phase extraction (μ-SPE) method, followed by liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) analysis. The μ-SPE device (∼0.8 × 1 cm) was fabricated by heat-sealing edges of a polypropylene membrane sheet to devise a bag enclosing the sorbent. The analytes (both carbamazepine and isotope-labelled carbamazepine) were first extracted by μ-SPE device in the sample (10 mL) via agitation, then desorbed in an organic solvent (1 mL) via ultrasonication. Several parameters such as organic solvent for pre-conditioning of μ-SPE device, amount of sorbent, adsorption time, and desorption solvent and time were investigated to optimize the μ-SPE efficiency. The optimized method has limits of detection and quantitation estimated to be 0.5 ng L{sup −1} and 1.6 ng L{sup −1}, respectively. Surface water samples spiked with different amounts of carbamazepine (close to 20, 500, and 1600 ng L{sup −1}, respectively) were analysed for the validation of method precision and accuracy. Good precision was obtained as demonstrated by relative standard deviations of 0.7% for the samples with concentrations of 500 and 1600 ng kg{sup −1}, and 5.8% for the sample with concentration of 20 ng kg{sup −1}. Good accuracy was also demonstrated by the relative recoveries in the range of 96.7%–103.5% for all samples with uncertainties of 1.1%–5.4%. Owing to the same chemical properties of carbamazepine and isotope-labelled carbamazepine, the isotope ratio in the μ-SPE procedure was accurately controlled. The use of μ-SPE coupled with IDMS analysis significantly facilitated the fast and accurate measurement of carbamazepine in surface water. - Highlights: • μ-SPE coupled with IDMS for the measurement of carbamazepine. • The method is the first report of coupling μ-SPE with IDMS. • μ-SPE is fast, time

  6. [Uncertainty evaluation of the determination of toxic equivalent quantity of polychlorinated dibenzo-p-dioxins and dibenzofurans in soil by isotope dilution high resolution gas chromatography and high resolution mass spectrometry].

    Science.gov (United States)

    Du, Bing; Liu Aimin; Huang, Yeru

    2014-09-01

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil samples were analyzed by isotope dilution method with high resolution gas chromatography and high resolution mass spectrometry (ID-HRGC/HRMS), and the toxic equivalent quantity (TEQ) were calculated. The impacts of major source of measurement uncertainty are discussed, and the combined relative standard uncertainties were calculated for each 2, 3, 7, 8 substituted con- gener. Furthermore, the concentration, combined uncertainty and expanded uncertainty for TEQ of PCDD/Fs in a soil sample in I-TEF, WHO-1998-TEF and WHO-2005-TEF schemes are provided as an example. I-TEF, WHO-1998-TEF and WHO-2005-TEF are the evaluation schemes of toxic equivalent factor (TEF), and are all currently used to describe 2,3,7,8 sub- stituted relative potencies.

  7. Nutrient Concentrations and Stable Isotopes of Runoff from a Midwest Tile-Drained Corn Field

    Science.gov (United States)

    Wilkins, B. P.; Woo, D.; Li, J.; Michalski, G. M.; Kumar, P.; Conroy, J. L.; Keefer, D. A.; Keefer, L. L.; Hodson, T. O.

    2017-12-01

    Tile drains are a common crop drainage device used in Midwest agroecosystems. While efficient at drainage, the tiles provide a quick path for nutrient runoff, reducing the time available for microbes to use nutrients (e.g., NO3- and PO43-) and reduce export to riverine systems. Thus, understanding the effects of tile drains on nutrient runoff is critical to achieve nutrient reduction goals. Here we present isotopic and concentration data collected from tile drain runoff of a corn field located near Monticello, IL. Tile flow samples were measured for anion concentrations and stable isotopes of H2O and NO3-, while precipitation was measured for dual isotopes of H2O. Results demonstrate early tile flow from rain events have a low Cl- concentration (60% contribution) in the beginning of the hydrograph. As flow continues H2O isotopic values reflect pre-event water (ground and soil water), and Cl- concentrations increase representing a greater influence by matrix flow (60-90% contribution). Nitrate concentrations change dramatically, especially during the growing season, and do not follow a similar trend as the conservative Cl-, often decreasing days before, which represents missing nitrate in the upper surface portion of the soil. Nitrate isotopic data shows significant changes in 15N (4‰) and 18O (4‰) during individual hydrological events, representing that in addition to plant uptake and leaching, considerate NO3- is lost through denitrification. It is notable, that throughout the season d15N and d18O of nitrate change significantly representing that seasonally, substantial denitrification occurs.

  8. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    Science.gov (United States)

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  9. Geochemistry of silicon isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Tiping; Li, Yanhe; Gao, Jianfei; Hu, Bin [Chinese Academy of Geological Science, Beijing (China). Inst. of Mineral Resources; Jiang, Shaoyong [China Univ. of Geosciences, Wuhan (China).

    2018-04-01

    Silicon is one of the most abundant elements in the Earth and silicon isotope geochemistry is important in identifying the silicon source for various geological bodies and in studying the behavior of silicon in different geological processes. This book starts with an introduction on the development of silicon isotope geochemistry. Various analytical methods are described and compared with each other in detail. The mechanisms of silicon isotope fractionation are discussed, and silicon isotope distributions in various extraterrestrial and terrestrial reservoirs are updated. Besides, the applications of silicon isotopes in several important fields are presented.

  10. Disposal of Low-Activity Liquid Effluents by Dilution

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Candillon, C. [Atomic Energy Commission, Saclay (France)

    1960-07-01

    Nuclear centres are frequently faced with problems of disposal of sizeable quantities of low-activity liquid effluents. Under present conditions the most practicable solution seems to be to discharge them into a natural or artificial water system, so as to dilute them as much as possible and thus reduce their radioactive isotope content below the public health levels. This technique is employed by all nuclear centres in France, which use the following convenient outlets: Saclay: the artificial ponds made by Louis XIV to feed the great Versailles fountains; Fontenay-aux-Roses: the Paris sewer system; Grenoble: the river Isere; Marcoule: the river Rhone. Until 1957 the amount of waste was negligible. It is still very slight at the first three centres, only a few dozen millicuries a month. At Marcoule the activity of the effluents is somewhat greater, but the Rhone's rate of flow ensures a very low final content of radioactive elements. The increasing discharge of wastes into river systems calls for a close watch on changes in radioactivity in the environment (i.e. in air, water and soil), and especially on areas in which radioactive isotopes may accumulate. We have therefore made laboratory studies of the mechanics of radioactivity concentration, in order to improve our sampling methods and ascertain the movement of wastes.

  11. Hydrochemistry and isotopic composition (δ{sup 13}C, δ{sup 15}N) in six dunes lagoons in the National Park of Lencois Maranhenses, Maranhao, Brazil; Hidroquimica e composicao isotopica (δ13C, δ15N) em seis lagoas de dunas no Parque Nacional dos Lencois Maranhenses, Maranhao, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Junior, Jayme Teixeira; Suzuki, Marina Satika; Meirelles, Brunele de Araujo; Rangel, Thiago Pessanha; Oliveira, Braulio Cherene Vaz de, E-mail: jaymetr@gmail.com, E-mail: marina@uenf.com, E-mail: brunelemeirelles@hotmail.com, E-mail: thiprangel@yahoo.com.br, E-mail: brauliocherene@hotmail.com [Universidade Estadual do Norte Fluminense (UENF), Campos dos Goytacazes, RJ (Brazil). Centro de Biociencias e Biotecnologia. Lab. de Ciencias Ambientais

    2015-07-01

    This study aims to evaluate the physicochemical parameters, nutrients and isotopic composition (δ{sup 13}C, δ{sup 15}N) of dissolved organic matter and MPS in six lakes located in the Maranhenses National Park, Maranhao State, under varying degrees of anthropic impact and distance from the sea. The physical and chemical parameters were measured in the field with portable devices; for total alkalinity, nutrients and photosynthetic pigments, samples were collected and analysed in the laboratory; the isotopic composition of carbon and nitrogen was determined from the particulate material retained on the filter and in the extract generated in the PPL filtration resin column. The limnological variables were assessed in both the dry and rainy seasons. The high rainfall caused a dilution effect for most of the elements studied in the rainy season. The elemental composition of the particulate fraction was 58% lower than the fraction dissolved. The carbon isotopic composition was lighter in the rainy season as a result of dilution and loading of allochthonous impoverished organic matter. (author)

  12. Simultaneous analysis of urinary phthalate metabolites of residents in Korea using isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Miok; Song, Na Rae; Choi, Jong-Ho; Lee, Jeongae; Pyo, Heesoo

    2014-02-01

    Phthalates are used in industry products, household items, and medical tools as plasticizers. Human exposure to phthalates has raised concern about its toxicity. In the present study, optimization was conducted for the simultaneous analysis of eight kinds of phthalate metabolites using gas chromatography-mass spectrometry (GC-MS): MEP, MiBP, MnBP, MBzP, MiNP, MEHP, MEOHP, and MEHHP. In order to minimize the matrix effect and to do quantitative analysis, isotope dilution and LLE-GC-MS methods were performed. Urine samples were enzymatically hydrolyzed, extracted with a mixture of n-hexane and ethyl ether (8:2; v:v), and subsequently derivatized with trimethylsilylation. All eight kinds of analytes showed clear resolution and high reproducibility in GC-MS results. The method detection limit ranged from 0.05 ng/mL to 0.2 ng/mL. Calibration curves were found to be linear from 0.2 to 100 ng/mL with -(2)>0.992. The relative standard deviation of the intraday precision using water and urine ranged from 2.1% to 16.3%. The analysis was performed with urine samples that were collected from adults residing in the Republic of Korea. The analyzed concentration results were compared according to gender and region. As a result, DEHP metabolites showed the highest detected concentration (75.92 μg/g creatinine, 100%), and MiNP, a metabolite of DiNP, showed the lowest detected concentration (0.42 μg/g creatinine, 22.5%). On average, female urine (200.76 μg/g creatinine) had a higher detected concentration of ∑8 phthalate metabolites than male urine. Samples from rural regions (211.96 μg/g creatinine) had higher levels than samples from urban regions. © 2013.

  13. Hybridizing pines with diluted pollen

    Science.gov (United States)

    Robert Z. Callaham

    1967-01-01

    Diluted pollens would have many uses by the tree breeder. Dilutions would be particularly advantageous in making many controlled pollinations with a limited amount of pollen. They also would be useful in artificial mass pollinations of orchards or single trees. Diluted pollens might help overcome troublesome genetic barriers to crossing. Feasibility o,f using diluted...

  14. Simultaneous determination of platinum group elements and rhenium in rock samples using isotope dilution inductively coupled plasma mass spectrometry after cation exchange separation followed by solvent extraction

    International Nuclear Information System (INIS)

    Shinotsuka, Kazunori; Suzuki, Katsuhiko

    2007-01-01

    A simple and precise determination method for platinum group elements (PGEs) and Re in rock samples was developed using isotope dilution coupled with inductively coupled plasma mass spectrometry (ID-ICP-MS). Cation exchange separation was employed for simplicity, because it is applicable to group separation and simultaneous isotopic measurement in contrast with the widely used anion exchange separation which entails separate elution. However, its application to ID-ICP-MS has been limited due to spectral interferences from impurities retained in the PGE fraction even after ion chromatography. To overcome this limitation, solvent extraction using N-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform was successfully applied for further purification. After the examination of optimum experimental parameters in cation exchange separation and solvent extraction using synthetic PGE solution, the established procedure was applied to the determination of PGEs and Re in some geochemical reference materials. The obtained results agreed well with the literature data determined using the different digestion methods (NiS fire assay and the use of a high-pressure asher) within the analytical uncertainties of each other. Significant difference in reproducibility between Ru, Ir, Pt and Os group, and Pd and Re group was observed in the results for BHVO-2 and JA-2. By considering the error factors affecting analytical reproducibility, we concluded that the difference is ascribed to the sample heterogeneity of minor minerals enriched in Ru, Ir, Pt and Os

  15. Differential Mobility-Mass Spectrometry Double Spike Isotope Dilution Study of Release of β-Methylaminoalanine and Proteinogenic Amino Acids during Biological Sample Hydrolysis.

    Science.gov (United States)

    Beach, Daniel G; Kerrin, Elliott S; Giddings, Sabrina D; Quilliam, Michael A; McCarron, Pearse

    2018-01-08

    The non-protein amino acid β-methylamino-L-alanine (BMAA) has been linked to neurodegenerative disease and reported throughout the environment. Proposed mechanisms of bioaccumulation, trophic transfer and chronic toxicity of BMAA rely on the hypothesis of protein misincorporation. Poorly selective methods for BMAA analysis have led to controversy. Here, a recently reported highly selective method for BMAA quantitation using hydrophilic interaction liquid chromatography-differential mobility spectrometry-tandem mass spectrometry (HILIC-DMS-MS/MS) is expanded to include proteinogenic amino acids from hydrolyzed biological samples. For BMAA quantitation, we present a double spiking isotope dilution approach using D 3 -BMAA and 13 C 15 N 2 -BMAA. These methods were applied to study release of BMAA during acid hydrolysis under a variety of conditions, revealing that the majority of BMAA can be extracted along with only a small proportion of protein. A time course hydrolysis of BMAA from mussel tissue was carried out to assess the recovery of BMAA during sample preparation. The majority of BMAA measured by typical methods was released before a significant proportion of protein was hydrolyzed. Little change was observed in protein hydrolysis beyond typical hydrolysis times but the concentration of BMAA increased linearly. These findings demonstrate protein misincorporation is not the predominant form of BMAA in cycad and shellfish.

  16. A level-playing field for medical isotope production - How to phase-out reliance on HEU

    International Nuclear Information System (INIS)

    Kuperman, A.J.

    1999-01-01

    Two decades ago, civilian commerce in highly enriched uranium (HEU) for use as targets in the production of medical isotopes was considered a relatively minor security concern for three reasons. First, the number of producers was small. Second, the amount of HEU involved was small. Third, the amount of HEU was dwarfed by the quantities of HEU in civilian commerce as fuel for nuclear research and test reactors. Now, however, all three variables have changed. First, as the use of medical isotopes has expanded rapidly, production programs are proliferating. Second, as the result of such new producers and the expansion of existing production facilities, the amounts of HEU involved are growing. Third, as the RERTR program has facilitated the phase-out of HEU as fuel in most research and test reactors, the quantities of HEU for isotope production have come to represent a significant percentage of global commerce in this weapons-usable material. Medical isotope producers in several states are cooperating with the RERTR program to convert to low-enriched uranium (LEU) targets within the next few years, and one already relies on LEU for isotope production. However, the three biggest isotope producers - in Canada and the European Union - continue to rely on HEU, creating a double-standard that endangers the goal of the RERTR program. Each of these three producers has expressed economic concerns about being put at a competitive disadvantage if it alone converts. This paper proposes forging a firmer international consensus that all present and future isotope producers should convert to LEU, and calls for codifying such a commitment in a statement of intent to be prepared by producers over the next year. With such a level playing field, no producer would need fear being put at a competitive disadvantage by conversion, or being stigmatized by pressure groups for continued reliance on HEU. The phase-out of all HEU commerce for isotope production could be achieved within about

  17. Cavity Ring-down Spectroscopy for Carbon Isotope Analysis with 2 μm Diode Laser

    International Nuclear Information System (INIS)

    Hiromoto, K.; Tomita, H.; Watanabe, K.; Kawarabayashi, J.; Iguchi, T.

    2009-01-01

    We have made a prototype based on CRDS with 2 μm diode laser for carbon isotope analysis of CO 2 in air. The carbon isotope ratio was obtained to be (1.085±0.012)x10 -2 which shows good agreement with the isotope ratio measured by the magnetic sector-type mass spectrometer within uncertainty. Hence, we demonstrated the carbon isotope analysis based on CRDS with 2 μm tunable diode laser.

  18. Electrochemical separation and isotopic determination of thallium at the nanogram level by surface ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Arden, J.W.

    1983-01-01

    A rapid low-blank procedure is described for the co-separation of thallium and lead by sequential cathodic and anodic electrodeposition from natural samples, especially complex natural silicates, for subsequent mass spectrometry. A micro anion-exchange procedure is also described for the separation of thallium and lead. Ion currents of 10 - 10 A can be obtained from 1 ng of thallium. The isotopic composition of 1 ng of thallium can be measured on a Faraday detector with a precision of 0.05-0.1%. The total procedural blank is 3 pg. By using stable isotope dilution, 0.2 ng of thallium can be measured with a precision of 0.6% with only a 2% blank correction. This allows the accurate determination of thallium in natural samples down to concentration levels of about 50 pg g - 1 . The detection limit is 50 fg. This procedure has been applied to meteorites and terrestrial rocks. The stable isotope dilution technique is suitable for geochemical, environmental and toxicological studies requiring a highly sensitive, accurate and precise method for the determination of thallium. (Auth.)

  19. Proceedings of the international colloque on the use of isotopic techniques in water and soil resources field

    International Nuclear Information System (INIS)

    Laboratoire de geochimie isotopique et de paleoclimatologie de l'ecole nationale d'ingenieurs, Sfax

    1996-01-01

    This colloque deals with the use of isotopic techniques in water and soil field. 24 papers were read. Experiences of Tunisia, Algeria, Morocco, Mexico and African equator region were exposed. Articles selected for INIS

  20. Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.

    Science.gov (United States)

    Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael

    2011-01-01

    New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.