WorldWideScience

Sample records for isometric force generation

  1. A component analysis of the generation and release of isometric force in Parkinson's disease.

    OpenAIRE

    Jordan, N; Sagar, H J; Cooper, J A

    1992-01-01

    Paradigms of isometric force control allow study of the generation and release of movement in the absence of complications due to disordered visuomotor coordination. The onset and release of isometric force in Parkinson's disease (PD) was studied, using computerised determinants of latency of response and rate of force generation and release. Components of isometric force control were related to measures of cognitive, affective and clinical motor disability. The effects of treatment were dete...

  2. Cryotherapy, Sensation, and Isometric-Force Variability

    Science.gov (United States)

    Denegar, Craig R.; Buckley, William E.; Newell, Karl M.

    2003-01-01

    Objective: To determine the changes in sensation of pressure, 2-point discrimination, and submaximal isometric-force production variability due to cryotherapy. Design and Setting: Sensation was assessed using a 2 × 2 × 2 × 3 repeated-measures factorial design, with treatment (ice immersion or control), limb (right or left), digit (finger or thumb), and sensation test time (baseline, posttreatment, or postisometric-force trials) as independent variables. Dependent variables were changes in sensation of pressure and 2-point discrimination. Isometric-force variability was tested with a 2 × 2 × 3 repeated-measures factorial design. Treatment condition (ice immersion or control), limb (right or left), and percentage (10, 25, or 40) of maximal voluntary isometric contraction (MVIC) were the independent variables. The dependent variables were the precision or variability (the standard deviation of mean isometric force) and the accuracy or targeting error (the root mean square error) of the isometric force for each percentage of MVIC. Subjects: Fifteen volunteer college students (8 men, 7 women; age = 22 ± 3 years; mass = 72 ± 21.9 kg; height = 183.4 ± 11.6 cm). Measurements: We measured sensation in the distal palmar aspect of the index finger and thumb. Sensation of pressure and 2-point discrimination were measured before treatment (baseline), after treatment (15 minutes of ice immersion or control), and at the completion of isometric testing (final). Variability (standard deviation of mean isometric force) of the submaximal isometric finger forces was measured by having the subjects exert a pinching force with the thumb and index finger for 30 seconds. Subjects performed the pinching task at the 3 submaximal levels of MVIC (10%, 25%, and 40%), with the order of trials assigned randomly. The subjects were given a target representing the submaximal percentage of MVIC and visual feedback of the force produced as they pinched the testing device. The force exerted

  3. Production of isometric forces during sustained acceleration.

    Science.gov (United States)

    Sand, D P; Girgenrath, M; Bock, O; Pongratz, H

    2003-06-01

    The operation of high-performance aircraft requires pilots to apply finely graded forces on controls. Since they are often exposed to high levels of acceleration in flight, we investigated to what extent this ability is degraded in such an environment. Twelve healthy non-pilot volunteers were seated in the gondola of a centrifuge and their performance was tested at normal gravity (1 G) and while exposed to sustained forces of 1.5 G and 3 G oriented from head to foot (+Gz). Using an isometric joystick, they attempted to produce force vectors with specific lengths and directions commanded in random order by a visual display. Acceleration had substantial effects on the magnitude of produced force. Compared with 1 G, maximum produced force was about 2 N higher at 1.5 G and about 10 N higher at 3 G. The size of this effect was constant across the different magnitudes, but varied with the direction of the prescribed force. Acceleration degrades control of force production. This finding may indicate that the motor system misinterprets the unusual gravitoinertial environment and/or that proprioceptive feedback is degraded due to increased muscle tone. The production of excessive isometric force could affect the safe operation of high-performance aircraft.

  4. Force-Time Entropy of Isometric Impulse.

    Science.gov (United States)

    Hsieh, Tsung-Yu; Newell, Karl M

    2016-01-01

    The relation between force and temporal variability in discrete impulse production has been viewed as independent (R. A. Schmidt, H. Zelaznik, B. Hawkins, J. S. Frank, & J. T. Quinn, 1979 ) or dependent on the rate of force (L. G. Carlton & K. M. Newell, 1993 ). Two experiments in an isometric single finger force task investigated the joint force-time entropy with (a) fixed time to peak force and different percentages of force level and (b) fixed percentage of force level and different times to peak force. The results showed that the peak force variability increased either with the increment of force level or through a shorter time to peak force that also reduced timing error variability. The peak force entropy and entropy of time to peak force increased on the respective dimension as the parameter conditions approached either maximum force or a minimum rate of force production. The findings show that force error and timing error are dependent but complementary when considered in the same framework with the joint force-time entropy at a minimum in the middle parameter range of discrete impulse.

  5. Development of isometric force and force control in children

    NARCIS (Netherlands)

    Smits-Engelsman, B.C.M.; Westenberg, Y.; Duysens, J.E.J.

    2004-01-01

    Fifty-six children between 5 and 12 years of age and 15 adults performed a task (pressing on a lever with the index finger of the preferred hand), in which a force had to be maintained constant at five levels with on-line visual feedback. Since this is a simple isometric task, the hypothesis is that

  6. Development of isometric force and force control in children.

    NARCIS (Netherlands)

    Smits-Engelsman, B.C.M.; Westenberg, Y.; Duysens, J.E.J.

    2003-01-01

    Fifty-six children between 5 and 12 years of age and 15 adults performed a task (pressing on a lever with the index finger of the preferred hand), in which a force had to be maintained constant at five levels with on-line visual feedback. Since this is a simple isometric task, the hypothesis is that

  7. Portfolio theory of optimal isometric force production: Variability predictions and nonequilibrium fluctuation dissipation theorem

    Science.gov (United States)

    Frank, T. D.; Patanarapeelert, K.; Beek, P. J.

    2008-05-01

    We derive a fundamental relationship between the mean and the variability of isometric force. The relationship arises from an optimal collection of active motor units such that the force variability assumes a minimum (optimal isometric force). The relationship is shown to be independent of the explicit motor unit properties and of the dynamical features of isometric force production. A constant coefficient of variation in the asymptotic regime and a nonequilibrium fluctuation-dissipation theorem for optimal isometric force are predicted.

  8. Portfolio theory of optimal isometric force production: Variability predictions and nonequilibrium fluctuation-dissipation theorem

    International Nuclear Information System (INIS)

    Frank, T.D.; Patanarapeelert, K.; Beek, P.J.

    2008-01-01

    We derive a fundamental relationship between the mean and the variability of isometric force. The relationship arises from an optimal collection of active motor units such that the force variability assumes a minimum (optimal isometric force). The relationship is shown to be independent of the explicit motor unit properties and of the dynamical features of isometric force production. A constant coefficient of variation in the asymptotic regime and a nonequilibrium fluctuation-dissipation theorem for optimal isometric force are predicted

  9. Cutaneous mechanisms of isometric ankle force control

    DEFF Research Database (Denmark)

    Choi, Julia T; Jensen, Jesper Lundbye; Leukel, Christian

    2013-01-01

    The sense of force is critical in the control of movement and posture. Multiple factors influence our perception of exerted force, including inputs from cutaneous afferents, muscle afferents and central commands. Here, we studied the influence of cutaneous feedback on the control of ankle force...... of transient stimulation on force error were greater when compared to continuous stimulation and lidocaine injection. Position-matching performance was unaffected by peroneal nerve or plantar nerve stimulation. Our results show that cutaneous feedback plays a role in the control of force output at the ankle...... joint. Understanding how the nervous system normally uses cutaneous feedback in motor control will help us identify which functional aspects are impaired in aging and neurological diseases....

  10. Experimental knee pain impairs submaximal force steadiness in isometric, eccentric, and concentric muscle actions.

    Science.gov (United States)

    Rice, David A; McNair, Peter J; Lewis, Gwyn N; Mannion, Jamie

    2015-09-12

    Populations with knee joint damage, including arthritis, have noted impairments in the regulation of submaximal muscle force. It is difficult to determine the exact cause of such impairments given the joint pathology and associated neuromuscular adaptations. Experimental pain models that have been used to isolate the effects of pain on muscle force regulation have shown impaired force steadiness during acute pain. However, few studies have examined force regulation during dynamic contractions, and these findings have been inconsistent. The goal of the current study was to examine the effect of experimental knee joint pain on submaximal quadriceps force regulation during isometric and dynamic contractions. The study involved fifteen healthy participants. Participants were seated in an isokinetic dynamometer. Knee extensor force matching tasks were completed in isometric, eccentric, and concentric muscle contraction conditions. The target force was set to 10 % of maximum for each contraction type. Hypertonic saline was then injected into the infrapatella fat pad to generate acute joint pain. The force matching tasks were repeated during pain and once more 5 min after pain had subsided. Hypertonic saline resulted in knee pain with an average peak pain rating of 5.5 ± 2.1 (0-10 scale) that lasted for 18 ± 4 mins. Force steadiness significantly reduced during pain across all three muscle contraction conditions. There was a trend to increased force matching error during pain but this was not significant. Experimental knee pain leads to impaired quadriceps force steadiness during isometric, eccentric, and concentric contractions, providing further evidence that joint pain directly affects motor performance. Given the established relationship between submaximal muscle force steadiness and function, such an effect may be detrimental to the performance of tasks in daily life. In order to restore motor performance in people with painful arthritic conditions of the

  11. Portfolio theory of optimal isometric force production: Variability predictions and nonequilibrium fluctuation-dissipation theorem

    NARCIS (Netherlands)

    Frank, T.D.; Patanarapeelert, K.; Beek, P.J.

    2008-01-01

    We derive a fundamental relationship between the mean and the variability of isometric force. The relationship arises from an optimal collection of active motor units such that the force variability assumes a minimum (optimal isometric force). The relationship is shown to be independent of the

  12. Relationships between Isometric Force-Time Characteristics and Dynamic Performance

    Directory of Open Access Journals (Sweden)

    Thomas Dos’Santos

    2017-09-01

    Full Text Available The purpose of this study was to explore the relationships between isometric mid-thigh pull (IMTP force-time characteristics (peak force and time-specific force vales (100–250 ms and dynamic performance and compare dynamic performance between stronger and weaker athletes. Forty-three athletes from different sports (rowing, soccer, bicycle motocross, and hockey performed three trials of the squat jump (SJ, countermovement jump (CMJ, and IMTP, and performed a one repetition maximum power clean (PC. Reactive strength index modified (RSImod was also calculated from the CMJ. Statistically significant large correlations between IMTP force-time characteristics and PC (ρ = 0.569–0.674, p < 0.001, and moderate correlations between IMTP force-time characteristics (excluding force at 100 ms and RSImod (ρ = 0.389–0.449, p = 0.013–0.050 were observed. Only force at 250 ms demonstrated a statistically significant moderate correlation with CMJ height (ρ = 0.346, p = 0.016 and no statistically significant associations were observed between IMTP force-time characteristics and SJ height. Stronger athletes (top 10 demonstrated statistically significantly greater CMJ heights, RSImods, and PCs (p ≤ 0.004, g = 1.32–1.89 compared to weaker (bottom 10 athletes, but no differences in SJ height were observed (p = 0.871, g = 0.06. These findings highlight that the ability to apply rapidly high levels of force in short time intervals is integral for PC, CMJ height, and reactive strength.

  13. Does combined strength training and local vibration improve isometric maximum force? A pilot study.

    Science.gov (United States)

    Goebel, Ruben; Haddad, Monoem; Kleinöder, Heinz; Yue, Zengyuan; Heinen, Thomas; Mester, Joachim

    2017-01-01

    The aim of the study was to determine whether a combination of strength training (ST) and local vibration (LV) improved the isometric maximum force of arm flexor muscles. ST was applied to the left arm of the subjects; LV was applied to the right arm of the same subjects. The main aim was to examine the effect of LV during a dumbbell biceps curl (Scott Curl) on isometric maximum force of the opposite muscle among the same subjects. It is hypothesized, that the intervention with LV produces a greater gain in isometric force of the arm flexors than ST. Twenty-seven collegiate students participated in the study. The training load was 70% of the individual 1 RM. Four sets with 12 repetitions were performed three times per week during four weeks. The right arm of all subjects represented the vibration trained body side (VS) and the left arm served as the traditional trained body side (TTS). A significant increase of isometric maximum force in both body sides (Arms) occurred. VS, however, significantly increased isometric maximum force about 43% in contrast to 22% of the TTS. The combined intervention of ST and LC improves isometric maximum force of arm flexor muscles. III.

  14. Fitts’ Law in the Control of Isometric Grip Force With Naturalistic Targets

    Directory of Open Access Journals (Sweden)

    Zachary C. Thumser

    2018-04-01

    Full Text Available Fitts’ law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts’ law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts’ law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task. Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task. Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback. This provided an opportunity to see if Fitts’ law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback. Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets to the more naturalistic and intuitive target forces implied by images of objects (implicit targets. With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts’ law (average r2 = 0.82. Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces

  15. Fitts' Law in the Control of Isometric Grip Force With Naturalistic Targets.

    Science.gov (United States)

    Thumser, Zachary C; Slifkin, Andrew B; Beckler, Dylan T; Marasco, Paul D

    2018-01-01

    Fitts' law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts' law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts' law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task). Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task). Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback). This provided an opportunity to see if Fitts' law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback). Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets) to the more naturalistic and intuitive target forces implied by images of objects (implicit targets). With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts' law (average r 2 = 0.82). Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces without the visualized

  16. Explosive force production during isometric squats correlates with athletic performance in rugby union players.

    Science.gov (United States)

    Tillin, Neale Anthony; Pain, Matthew Thomas Gerard; Folland, Jonathan

    2013-01-01

    This study investigated the association between explosive force production during isometric squats and athletic performance (sprint time and countermovement jump height). Sprint time (5 and 20 m) and jump height were recorded in 18 male elite-standard varsity rugby union players. Participants also completed a series of maximal- and explosive-isometric squats to measure maximal force and explosive force at 50-ms intervals up to 250 ms from force onset. Sprint performance was related to early phase (≤100 ms) explosive force normalised to maximal force (5 m, r = -0.63, P = 0.005; and 20 m, r = -0.54, P = 0.020), but jump height was related to later phase (>100 ms) absolute explosive force (0.51 squats (33-67%; 0.001 squats was associated with athletic performance. Specifically, sprint performance was most strongly related to the proportion of maximal force achieved in the initial phase of explosive-isometric squats, whilst jump height was most strongly related to absolute force in the later phase of the explosive-isometric squats.

  17. Relationship Between Force Production During Isometric Squats and Knee Flexion Angles During Landing.

    Science.gov (United States)

    Fisher, Harry; Stephenson, Mitchell L; Graves, Kyle K; Hinshaw, Taylour J; Smith, Derek T; Zhu, Qin; Wilson, Margaret A; Dai, Boyi

    2016-06-01

    Decreased knee flexion angles during landing are associated with increased anterior cruciate ligament loading. The underlying mechanisms associated with decreased self-selected knee flexion angles during landing are still unclear. The purpose of this study was to establish the relationship between the peak force production at various knee flexion angles (35, 55, 70, and 90°) during isometric squats and the actual knee flexion angles that occur during landing in both men and women. A total of 18 men and 18 women recreational/collegiate athletes performed 4 isometric squats at various knee flexion angles while vertical ground reaction forces were recorded. Participants also performed a jump-landing-jump task while lower extremity kinematics were collected. For women, significant correlations were found between the peak force production at 55 and 70° of knee flexion during isometric squats and the knee flexion angle at initial contact of landing. There were also significant correlations between the peak force production at 55, 70, and 90° of knee flexion during isometric squats and the peak knee flexion angle during landing. These correlations tended to be stronger during isometric squats at greater knee flexion compared with smaller knee flexion. No significant correlations were found for men. Posture-specific strength may play an important role in determining self-selected knee flexion angles during landing for women.

  18. Modular Organization of Exploratory Force Development Under Isometric Conditions in the Human Arm.

    Science.gov (United States)

    Roh, Jinsook; Lee, Sang Wook; Wilger, Kevin D

    2018-01-31

    Muscle coordination of isometric force production can be explained by a smaller number of modules. Variability in force output, however, is higher during exploratory/transient force development phases than force maintenance phase, and it is not clear whether the same modular structure underlies both phases. In this study, eight neurologically-intact adults isometrically performed target force matches in 54 directions at hands, and electromyographic (EMG) data from eight muscles were parsed into four sequential phases. Despite the varying degree of motor complexity across phases (significant between-phase differences in EMG-force correlation, angular errors, and between-force correlations), the number/composition of motor modules were found equivalent across phases, suggesting that the CNS systematically modulated activation of the same set of motor modules throughout sequential force development.

  19. Electromyographic signal and force comparisons during maximal voluntary isometric contraction in water and on dry land.

    Science.gov (United States)

    Pinto, Stephanie Santana; Liedtke, Giane Veiga; Alberton, Cristine Lima; da Silva, Eduardo Marczwski; Cadore, Eduardo Lusa; Kruel, Luiz Fernando Martins

    2010-11-01

    This study was designed to compare surface electromyographic (sEMG) signal and force production during maximal voluntary isometric contractions (MVCs) in water and on dry land. The reproducibility of sEMG and isometric force measurements between water and dry land environments was also assessed. Nine women performed MVC for elbow flexion and extension, hip flexion, and extension against identical fixed resistance in both environments. The sEMG signal from biceps brachii, triceps brachii, rectus femoris, and biceps femoris was recorded with waterproof adhesives placed over each electrode. The sEMG and force production showed no significant difference between water and dry land, except for HEX (p = 0.035). In addition, intraclass correlation coefficient values were significant and ranged from moderate to high (0.66-0.96) for sEMG and force production between environments. These results showed that the environment did not influence the sEMG and force in MVC.

  20. Effects of age and content of augmented feedback on learning an isometric force-production task

    NARCIS (Netherlands)

    van Dijk, Henk; Mulder, Theo; Hermens, Hermie J.

    2007-01-01

    This study addressed the interaction between age and the informational content of feedback on learning an isometric force-production task. Healthy men and women (30 young adults: 20 to 35 years; 30 older adults: 55 to 70 years) were randomly assigned to a certain type of feedback: knowledge of

  1. Strength training does not affect the accuracy of force gradation in an isometric force task in young men.

    NARCIS (Netherlands)

    Smits-Engelsman, B.C.M.; Smits, R.; Oomen, J.; Duysens, J.E.J.

    2008-01-01

    The aim of this study is to investigate potential differences in fine motor control between strength trained (ST) and non-strength trained (NT) individuals. By use of an isometric force production task, two groups, 20 ST (mean age 25.6, SD 4.9) and 19 NT (mean age 24.1, SD 2.9) male individuals,

  2. Fractal based complexity measure and variation in force during sustained isometric muscle contraction: effect of aging.

    Science.gov (United States)

    Arjunan, Sridhar P; Kumar, Dinesh K; Bastos, Teodiano

    2012-01-01

    This study has investigated the effect of age on the fractal based complexity measure of muscle activity and variance in the force of isometric muscle contraction. Surface electromyogram (sEMG) and force of muscle contraction were recorded from 40 healthy subjects categorized into: Group 1: Young - age range 20-30; 10 Males and 10 Females, Group 2: Old - age range 55-70; 10 Males and 10 Females during isometric exercise at Maximum Voluntary contraction (MVC). The results show that there is a reduction in the complexity of surface electromyogram (sEMG) associated with aging. The results demonstrate that there is an increase in the coefficient of variance (CoV) of the force of muscle contraction and a decrease in complexity of sEMG for the Old age group when compared with the Young age group.

  3. Isometric force exaggeration in simulated weightlessness by water immersion: role of visual feedback.

    Science.gov (United States)

    Dalecki, Marc; Bock, Otmar

    2014-06-01

    Previous studies reported that humans produce exaggerated isometric forces (20-50%) in microgravity, hypergravity, and under water. Subjects were not provided with visual feedback and exaggerations were attributed to proprioceptive deficits. The few studies that provided visual feedback in micro- and hypergravity found no deficits. The present work was undertaken to find out whether visual feedback can reduce or eliminate isometric force exaggerations during shallow water immersion, a working environment for astronauts and divers. There were 48 subjects who had to produce isometric forces of 15 N with a joystick; targets were presented via screen. Procedures were similar to earlier studies, but provided visual feedback. Subjects were tested 16.4 ft (5 m) under water (WET) and on dry land (DRY). Response accuracy was calculated with landmarks such as initial and peak force magnitude, and response timing. Initial force and response timing were equal in WET compared to DRY. A small but significant force exaggeration (+5%) remained for peak force in WET that was limited to directions toward the trunk. Force exaggeration under water is largely compensated, but not completely eliminated by visual feedback. As in earlier studies without visual feedback, force exaggeration manifested during later but not early response parts, speaking for impaired proprioceptive feedback rather than for erroneous central motor planning. Since in contrast to micro/hypergravity, visual feedback did not sufficiently abolish force deficits under water, proprioceptive information seems to be weighted differently in micro/hypergravity and shallow water immersion, probably because only the latter environment produces increased ambient pressure, which is known to induce neuronal changes.

  4. The force dependence of isometric and concentric potentiation in mouse muscle with and without skeletal myosin light chain kinase.

    Science.gov (United States)

    Gittings, William; Aggarwal, Harish; Stull, James T; Vandenboom, Rene

    2015-01-01

    The isometric potentiation associated with myosin phosphorylation is force dependent. The purpose of this study was to assess the influence of a pre-existing period of isometric force on the concentric force potentiation displayed by mouse muscles with and without the ability to phosphorylate myosin. We tested isometric (ISO) and concentric (CON) potentiation, as well as concentric potentiation after isometric force (ISO-CON), in muscles from wild-type (WT) and skeletal myosin light chain kinase-deficient (skMLCK(-/-)) mice. A conditioning stimulus increased (i.e., potentiated) mean concentric force in the ISO-CON and CON conditions to 1.31 ± 0.02 and 1.35 ± 0.02 (WT) and to 1.19 ± 0.02 and 1.21 ± 0.01 (skMLCK(-/-)) of prestimulus levels, respectively (data n = 6-8, p muscles.

  5. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    Science.gov (United States)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  6. Effects of adding whole body vibration to squat training on isometric force/time characteristics.

    Science.gov (United States)

    Lamont, Hugh S; Cramer, Joel T; Bemben, Debra A; Shehab, Randa L; Anderson, Mark A; Bemben, Michael G

    2010-01-01

    Resistance training interventions aimed at increasing lower-body power and rates of force development have produced varying results. Recent studies have suggested that whole-body low-frequency vibration (WBLFV) may elicit an acute postactivation potentiation response, leading to acute improvements in power and force development. Potentially, the use of WBLFV between sets of resistance training rather than during training itself may lead to increased recruitment and synchronization of high-threshold motor units, minimize fatigue potential, and facilitate the chronic adaptation to resistance exercise. The purpose of this study was to determine the effects of applying TriPlaner, WBLFV, prior to and then intermittently between sets of Smith machine squats on short-term adaptations in explosive isometric force expression. Thirty recreationally resistance trained men aged 18-30 were randomly assigned to 1 of 3 groups: resistance training only (SQT, n = 11), resistance plus whole-body vibration (SQTV, n = 13), or active control (CON, n = 6). An isometric squat test was performed prior to and following a 6-week periodized Smith machine squat program. Whole-body low-frequency vibration was applied 180 seconds prior to the first work set (50 Hz, 2-4 mm, 30 seconds) and intermittently (50 Hz, 4-6 mm, 3 x 10 seconds, 60 seconds between exposures) within a 240-second interset rest period. Subjects were instructed to assume a quarter squat posture while positioning their feet directly under their center of mass, which was modified using a handheld goniometer to a knee angle of 135 +/- 5 degrees . Instructions were given to subjects to apply force as fast and as hard as possible for 3.5 seconds. Isometric force (N) and rates of force development (N.s(-1)) were recorded from the onset of contraction (F(0)) to time points corresponding to 30, 50, 80, 100, 150, and 250 milliseconds, as well as the peak isometric rate of force development (PISORFD), and rate of force development to

  7. Firing rate modulation of human motor units in different muscles during isometric contraction with various forces.

    Science.gov (United States)

    Seki, K; Narusawa, M

    1996-05-06

    To examine the factors affecting the control of human motor units, rate coding strategies of the motor units were investigated in upper limb and intrinsic hand muscles during voluntary isometric contraction of steady force levels up to 80% of maximal voluntary contraction. Numerous spike trains from single motor units were recorded from the m. first dorsal interosseous (FDI) and the m. biceps brachii (BB) of eight human subjects by means of tungsten micro-electrodes, and the mean firing rate (MFR) was calculated for each subject and inter-individual comparisons made. The MFRs of the FDI were larger than that of the BB at the higher force level, and substantial differences were not found between these muscles at the lower force level. The slope of the linear regression line of MFRs vs. exerted forces for the FDI was more than twice that for the BB. Therefore, isometric force control of the FDI depends more on the rate coding strategy. The difference in rate coding between the FDI and BB motor units may be determined by factors other than muscle fiber composition, because both muscles are known to possess a similar composition of fiber types. Possible mechanisms underlying these characteristics of rate coding strategy are considered in this report.

  8. Selective visual scaling of time-scale processes facilitates broadband learning of isometric force frequency tracking.

    Science.gov (United States)

    King, Adam C; Newell, Karl M

    2015-10-01

    The experiment investigated the effect of selectively augmenting faster time scales of visual feedback information on the learning and transfer of continuous isometric force tracking tasks to test the generality of the self-organization of 1/f properties of force output. Three experimental groups tracked an irregular target pattern either under a standard fixed gain condition or with selectively enhancement in the visual feedback display of intermediate (4-8 Hz) or high (8-12 Hz) frequency components of the force output. All groups reduced tracking error over practice, with the error lowest in the intermediate scaling condition followed by the high scaling and fixed gain conditions, respectively. Selective visual scaling induced persistent changes across the frequency spectrum, with the strongest effect in the intermediate scaling condition and positive transfer to novel feedback displays. The findings reveal an interdependence of the timescales in the learning and transfer of isometric force output frequency structures consistent with 1/f process models of the time scales of motor output variability.

  9. Relations Between Lower Body Isometric Muscle Force Characteristics and Start Performance in Elite Male Sprint Swimmers

    Directory of Open Access Journals (Sweden)

    Igor Beretić

    2013-12-01

    Full Text Available The aim of the present study was twofold. The first aim was to examine the influence of absolute and relative lower body muscle force on kinematic component which determine the start performance. The second aim was to create multiregressional model which could use as a tool for swimming coaches with the purpose to start performance control and improvement. Twenty seven high-level trained male competitive swimmers all members of the Serbian National Youth and Senior Swimming Team (Age = 21.1 ± 4.3 yrs., Height = 1. 89 ± 0.10 m, Weight = 81.6 ± 8.4 kg, 50m freestyle - long course = 24.36 ± 0.86 s performed two trials of standing leg extensors isometric muscle force testing and three swimming start trials corresponding to 10m distance. The average start time significantly correlated with variables of leg extensors maximum voluntary force (Fmax, r = -0.559, p = 0.002, leg extensors relative muscle voluntary force (Frel, r = -0.727, p < 0.001, leg extensors specific rate of force development (RFD50%, r = -0.338, p = 0.047 and leg extensors relative value of specific rate of force development (RFD50%rel, r = -0.402, p = 0.040. Regression equation for t10m prediction was defined by following variables: maximum voluntary isometric force of leg extensors muscles at absolute and relative level (Fmax and Frel, as well as a specific rate of force development of the same muscle groups (RFD50% and RFD50%rel at absolute and relative level too with 74.4% of explained variance. Contractile abilities indicators of the leg extensors muscles included consideration: Fmax, RFD50%, Frel and RFD50%rel showed significant correlation with swimming start times on 10m. Additionally, the results suggest that swimmers, who possess greater isometric maximum force and specific rate of force development at absolute and relative levels, tend to be able to swim faster on initial 10m swim start perforamnce.

  10. Age-related decreases in motor unit discharge rate and force control during isometric plantar flexion

    DEFF Research Database (Denmark)

    Kallio, J; Søgaard, Karen; Avela, J

    2012-01-01

    Aging is related to multiple changes in muscle physiology and function. Previous findings concerning the effects of aging on motor unit discharge rate (DR) and fluctuations in DR and force are somewhat contradictory. Eight YOUNG and nine OLD physically active males performed isometric ramp (RECR......) and isotonic (ISO) plantar flexions at 10 and 20% of surface EMG at MVC. Motor unit (MU) action potentials were recorded with intramuscular fine-wire electrodes and decomposed with custom build software "Daisy". DR was lower in OLD in RECR-10% (17.9%, p...

  11. Influence of Whole Body Vibration and Specific Warm-ups on Force during an Isometric Mid-Thigh Pull

    Directory of Open Access Journals (Sweden)

    Vanessa L. Cazás-Moreno

    2015-10-01

    Full Text Available Purpose: The purpose of this study was to investigate the effects of general and specific warm-up protocols on rate of force development (RFD, relative RFD (rRFD, ground reaction force (GRF and relative ground reaction force (rGRF during an isometric mid-thigh pull (IMTP, after WBV exposure. Methods: Fifteen healthy recreationally trained males  (age: 24.1 ± 2.3 yrs, height: 72.9 ± 7.8 cm; mass: 86.9 ± 8.3 completed five protocols: baseline, isometric vibration (iVib, isometric no vibration (iNV, dynamic vibration (dVib and dynamic no vibration (dNV. The baseline was completed without any warm-up prior to the IMTP. The intervention protocols had the same prescription of 4 sets of 30-second bouts of quarter squats (dynamic [DQS] and isometric [IQS] on the WBV platform with or without vibration. Following a one-minute rest period after each protocol, participants completed three maximal IMTPs. Results: Repeated measures ANOVA with a Bonferroni post hoc demonstrated that RFD in dNV (7657.8 ± 2292.5 N/s was significantly greater than iVib (7156.4 ± 2170.0 N/s. However, the other experimental trials for RFD demonstrated no significant differences (p>0.05. There were also no significant differences for rRFD, GRF or rGRF between protocols. Conclusion: These results demonstrate that a dynamic warm-up without WBV elicits greater RFD than an isometric warm-up with WBV prior to a maximal isometric exercise. Further research needs to be investigated utilizing dynamic and isometric warm-ups in conjunction with WBV and power output. Keywords: males, recreationally trained, power

  12. Effects of Jaw Clenching and Jaw Alignment Mouthpiece Use on Force Production During Vertical Jump and Isometric Clean Pull.

    Science.gov (United States)

    Allen, Charles R; Fu, Yang-Chieh; Cazas-Moreno, Vanessa; Valliant, Melinda W; Gdovin, Jacob R; Williams, Charles C; Garner, John C

    2018-01-01

    Allen, CR, Fu, Y-C, Cazas-Moreno, V, Valliant, MW, Gdovin, JR, Williams, CC, and Garner, JC. Effects of jaw clenching and jaw alignment mouthpiece use on force production during vertical jump and isometric clean pull. J Strength Cond Res 32(1): 237-243, 2018-This study examined the effects of jaw clenching, a self-adapted, jaw-repositioning mouthpiece on force production during maximum countermovement vertical jump and maximum isometric midthigh clean pull assessments in an attempt to determine any ergogenic effect attributable to clenching, jaw-repositioning mouthpiece use, or the combination of both. Thirty-six male subjects performed vertical jump and isometric clean pull assessments from a force platform under various mouthpiece and clench conditions. A 3 × 2 (mouthpiece × clench) repeated-measures analysis of variance was conducted to analyze each of the following force production variables for both assessments: peak force, normalized peak force, and rate of force development. In addition, jump height was analyzed for the vertical jump. Results revealed improvements in peak force (F1,35 = 15.84, p ≤ 0.001, (Equation is included in full-text article.)= 0.31), normalized peak force (F1,35 = 16.28, p ≤ 0.001, (Equation is included in full-text article.)= 0.32), and rate of force development (F1,35 = 12.89, p = 0.001, (Equation is included in full-text article.)= 0.27) during the isometric clean pull assessment when participants maximally clenched their jaw, regardless of mouthpiece condition. There were no statistically significant differences in jump height, peak force, normalized peak force, or rate of force development during the vertical jump for any treatment condition. This study supports previous research demonstrating that the implementation of remote voluntary contractions such as jaw clenching can lead to concurrent activation potentiation and a resulting ergogenic effect during activities involving and requiring high-force production.

  13. EMG and force production of the flexor hallucis longus muscle in isometric plantarflexion and the push-off phase of walking.

    Science.gov (United States)

    Péter, Annamária; Hegyi, András; Stenroth, Lauri; Finni, Taija; Cronin, Neil J

    2015-09-18

    Large forces are generated under the big toe in the push-off phase of walking. The largest flexor muscle of the big toe is the flexor hallucis longus (FHL), which likely contributes substantially to these forces. This study examined FHL function at different levels of isometric plantarflexion torque and in the push-off phase at different speeds of walking. FHL and calf muscle activity were measured with surface EMG and plantar pressure was recorded with pressure insoles. FHL activity was compared to the activity of the calf muscles. Force and impulse values were calculated under the big toe, and were compared to the entire pressed area of the insole to determine the relative contribution of big toe flexion forces to the ground reaction force. FHL activity increased with increasing plantarflexion torque level (F=2.8, P=0.024) and with increasing walking speed (F=11.608, Ppush-off phase of walking, peak force under the big toe increased at a higher rate than force under the other areas of the plantar surface (F=3.801, P=0.018), implying a greater relative contribution to total force at faster speeds. Moreover, substantial differences were found between isometric plantarflexion and walking concerning FHL activity relative to that of the calf muscles, highlighting the task-dependant behaviour of FHL. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Isometric shoulder muscle activation patterns for 3-D planar forces: a methodology for musculo-skeletal model validation

    NARCIS (Netherlands)

    Groot, J.H.; Rozendaal, L.A.; Meskers, C.G.M.; Arwert, H.J.

    2004-01-01

    Objective. To present an isometric method for validation of a shoulder model simulation by means of experimentally obtained electromyography and addressing all muscles active around the shoulder joints. Background. Analysis of muscle force distribution in the shoulder by means of electromyography

  15. Temperature effect on the rates of isometric force development and relaxation in the fresh and fatigued human adductor pollicis muscle

    NARCIS (Netherlands)

    de Ruiter, C J; Jones, D A; Sargeant, A J; de Haan, A

    1999-01-01

    The purpose of the present study was to investigate the effect of temperature on the rates of isometric force development and relaxation in electrically activated fresh and fatigued human adductor pollicis muscle. Following immersion of the lower arm for 20 min in water baths of four different

  16. An ergonomic modular foot platform for isometric force/torque measurements in poststroke functional assessment: A pilot study

    OpenAIRE

    Stefano Mazzoleni, PhD; Jo Van Vaerenbergh, PhD; Emma Stokes, PhD; Gábor Fazekas, MD, PhD; Paolo Dario, PhD; Eugenio Guglielmelli, PhD

    2012-01-01

    The main goal of this article is to present the design, technical development, and preliminary validation of an innovative mechatronic device for force/torque measurements taken from the human foot using pilot data. The device, formed by a mobile platform equipped with two six-axis force/torque sensors, was used to perform accurate quantitative measurements during isometric exercises, aimed at performing functional assessment tests in poststroke patients undergoing a rehabilitation treatment....

  17. Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason R.; Nash, Roxanne E.; Sinka, Joseph; Bloomberg, Jacob J.

    2009-01-01

    Maximal power output occurs when subjects perform ballistic exercises using loads of 30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of

  18. Human movement onset detection from isometric force and torque measurements: a supervised pattern recognition approach.

    Science.gov (United States)

    Soda, Paolo; Mazzoleni, Stefano; Cavallo, Giuseppe; Guglielmelli, Eugenio; Iannello, Giulio

    2010-09-01

    Recent research has successfully introduced the application of robotics and mechatronics to functional assessment and motor therapy. Measurements of movement initiation in isometric conditions are widely used in clinical rehabilitation and their importance in functional assessment has been demonstrated for specific parts of the human body. The determination of the voluntary movement initiation time, also referred to as onset time, represents a challenging issue since the time window characterizing the movement onset is of particular relevance for the understanding of recovery mechanisms after a neurological damage. Establishing it manually as well as a troublesome task may also introduce oversight errors and loss of information. The most commonly used methods for automatic onset time detection compare the raw signal, or some extracted measures such as its derivatives (i.e., velocity and acceleration) with a chosen threshold. However, they suffer from high variability and systematic errors because of the weakness of the signal, the abnormality of response profiles as well as the variability of movement initiation times among patients. In this paper, we introduce a technique to optimise onset detection according to each input signal. It is based on a classification system that enables us to establish which deterministic method provides the most accurate onset time on the basis of information directly derived from the raw signal. The approach was tested on annotated force and torque datasets. Each dataset is constituted by 768 signals acquired from eight anatomical districts in 96 patients who carried out six tasks related to common daily activities. The results show that the proposed technique improves not only on the performance achieved by each of the deterministic methods, but also on that attained by a group of clinical experts. The paper describes a classification system detecting the voluntary movement initiation time and adaptable to different signals. By

  19. Comparison of the Relationship between Lying and Standing Ultrasonography Measures of Muscle Morphology with Isometric and Dynamic Force Production Capabilities

    Directory of Open Access Journals (Sweden)

    John P. Wagle

    2017-11-01

    Full Text Available The purpose of the current study was (1 to examine the differences between standing and lying measures of vastus lateralis (VL, muscle thickness (MT, pennation angle (PA, and cross-sectional area (CSA using ultrasonography; and (2 to explore the relationships between lying and standing measures with isometric and dynamic assessments of force production—specifically peak force, rate of force development (RFD, impulse, and one-repetition maximum back squat. Fourteen resistance-trained subjects (age = 26.8 ± 4.0 years, height = 181.4 ± 6.0 cm, body mass = 89.8 ± 10.7 kg, back squat to body mass ratio = 1.84 ± 0.34 agreed to participate. Lying and standing ultrasonography images of the right VL were collected following 48 hours of rest. Isometric squat assessments followed ultrasonography, and were performed on force platforms with data used to determine isometric peak force (IPF, as well as RFD and impulse at various time points. Forty-eight hours later, one-repetition maximum back squats were performed by each subject. Paired-samples t-tests revealed statistically significant differences between standing and lying measurements of MT (p < 0.001, PA (p < 0.001, and CSA (p ≤ 0.05, with standing values larger in all cases. Further, standing measures were correlated more strongly and abundantly to isometric and dynamic performance. These results suggest that if practitioners intend to gain insight into strength-power potential based on ultrasonography measurements, performing the measurement collection with the athlete in a standing posture may be preferred.

  20. Estimations of One Repetition Maximum and Isometric Peak Torque in Knee Extension Based on the Relationship Between Force and Velocity.

    Science.gov (United States)

    Sugiura, Yoshito; Hatanaka, Yasuhiko; Arai, Tomoaki; Sakurai, Hiroaki; Kanada, Yoshikiyo

    2016-04-01

    We aimed to investigate whether a linear regression formula based on the relationship between joint torque and angular velocity measured using a high-speed video camera and image measurement software is effective for estimating 1 repetition maximum (1RM) and isometric peak torque in knee extension. Subjects comprised 20 healthy men (mean ± SD; age, 27.4 ± 4.9 years; height, 170.3 ± 4.4 cm; and body weight, 66.1 ± 10.9 kg). The exercise load ranged from 40% to 150% 1RM. Peak angular velocity (PAV) and peak torque were used to estimate 1RM and isometric peak torque. To elucidate the relationship between force and velocity in knee extension, the relationship between the relative proportion of 1RM (% 1RM) and PAV was examined using simple regression analysis. The concordance rate between the estimated value and actual measurement of 1RM and isometric peak torque was examined using intraclass correlation coefficients (ICCs). Reliability of the regression line of PAV and % 1RM was 0.95. The concordance rate between the actual measurement and estimated value of 1RM resulted in an ICC(2,1) of 0.93 and that of isometric peak torque had an ICC(2,1) of 0.87 and 0.86 for 6 and 3 levels of load, respectively. Our method for estimating 1RM was effective for decreasing the measurement time and reducing patients' burden. Additionally, isometric peak torque can be estimated using 3 levels of load, as we obtained the same results as those reported previously. We plan to expand the range of subjects and examine the generalizability of our results.

  1. Improvements in force variability and structure from vision- to memory-guided submaximal isometric knee extension in subacute stroke.

    Science.gov (United States)

    Chow, John W; Stokic, Dobrivoje S

    2018-03-01

    We examined changes in variability, accuracy, frequency composition, and temporal regularity of force signal from vision-guided to memory-guided force-matching tasks in 17 subacute stroke and 17 age-matched healthy subjects. Subjects performed a unilateral isometric knee extension at 10, 30, and 50% of peak torque [maximum voluntary contraction (MVC)] for 10 s (3 trials each). Visual feedback was removed at the 5-s mark in the first two trials (feedback withdrawal), and 30 s after the second trial the subjects were asked to produce the target force without visual feedback (force recall). The coefficient of variation and constant error were used to quantify force variability and accuracy. Force structure was assessed by the median frequency, relative spectral power in the 0-3-Hz band, and sample entropy of the force signal. At 10% MVC, the force signal in subacute stroke subjects became steadier, more broadband, and temporally more irregular after the withdrawal of visual feedback, with progressively larger error at higher contraction levels. Also, the lack of modulation in the spectral frequency at higher force levels with visual feedback persisted in both the withdrawal and recall conditions. In terms of changes from the visual feedback condition, the feedback withdrawal produced a greater difference between the paretic, nonparetic, and control legs than the force recall. The overall results suggest improvements in force variability and structure from vision- to memory-guided force control in subacute stroke despite decreased accuracy. Different sensory-motor memory retrieval mechanisms seem to be involved in the feedback withdrawal and force recall conditions, which deserves further study. NEW & NOTEWORTHY We demonstrate that in the subacute phase of stroke, force signals during a low-level isometric knee extension become steadier, more broadband in spectral power, and more complex after removal of visual feedback. Larger force errors are produced when recalling

  2. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    OpenAIRE

    Schans, van der, C.P.; Zijlstra, W.; Regterschot, G.R.H.; Krijnen, W.P.; Douma, K.W.; Slager, G.E.C.

    2016-01-01

    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various d...

  3. Whole-body isometric force/torque measurements for functional assessment in neuro-rehabilitation: platform design, development and verification

    Directory of Open Access Journals (Sweden)

    Cavallo Giuseppe

    2009-10-01

    Full Text Available Abstract Background One of the main scientific and technological challenges of rehabilitation bioengineering is the development of innovative methodologies, based on the use of appropriate technological devices, for an objective assessment of patients undergoing a rehabilitation treatment. Such tools should be as fast and cheap to use as clinical scales, which are currently the daily instruments most widely used in the routine clinical practice. Methods A human-centered approach was used in the design and development of a mechanical structure equipped with eight force/torque sensors that record quantitative data during the initiation of a predefined set of Activities of Daily Living (ADL tasks, in isometric conditions. Results Preliminary results validated the appropriateness, acceptability and functionality of the proposed platform, that has become now a tool used for clinical research in three clinical centres. Conclusion This paper presented the design and development of an innovative platform for whole-body force and torque measurements on human subjects. The platform has been designed to perform accurate quantitative measurements in isometric conditions with the specific aim to address the needs for functional assessment tests of patients undergoing a rehabilitation treatment as a consequence of a stroke. The versatility of the system also enlightens several other interesting possible areas of application for therapy in neurorehabilitation, for research in basic neuroscience, and more.

  4. Effects of one-night sleep deprivation on selective attention and isometric force in adolescent karate athletes.

    Science.gov (United States)

    Ben Cheikh, Ridha; Latiri, Imed; Dogui, Mohamed; Ben Saad, Helmi

    2017-06-01

    Most of the available literature related to aspects of sleep deprivation is primarily focused on memory and learning, and studies regarding its effects on selective attention and/or physical performance are scarce. Moreover, the available literature includes general population or people involved in team sports (e.g. volleyball). However, only few studies were performed on athletes involved in combat sports (e.g. karate). The aim of the present study was to determine the effects of a total one-night sleep deprivation (1NSD) on activation and inhibition processes of selective attention and on maximal isometric force in karate athletes. Twelve young karate athletes (mean age 16.9±0.8 years) were enrolled. The protocol consists of two successive sessions: a normal night's sleep (NNS) and a total 1NSD. After each night, athletes performed selective attention and muscle strength tests during the same following three times (T) of the day: T1NNS or T11NSD: 8-9 a.m.; T2NNS or T21NSD: 12 a.m.-1 p.m.; T3NNS or T31NSD: 4-5 p.m. Activation (simple [SRT] and choice reaction times [CRT]) and inhibition (negative priming) processes were evaluated using Superlab v. 4.5 software (Cedrus Corporation, San Pedro, CA, USA). Maximal force and maximal force time (MFT) of brachial biceps isometric contraction were evaluated (Ergo System®, Globus, Codognè, Italy). A non-parametric test was used to evaluate the sessions (NNS vs. SND for the same time period) and time (T1NNS vs. 1NSD) effects. All athletes completed all tests after a NNS. Twelve, eleven and four athletes completed all tests at T11NSD, T21NSD and T31NSD, respectively. As for sessions effects, no statistically significant difference was found. As for time effects, a significant increase in SRT at T21NSD vs. T1NNS (345±47 vs. 317±33 ms, respectively), a significant increase in MFT at T21NSD vs. T1NNS (2172±260 vs.1885±292 ms, respectively), and no significant changes in CRT and negative priming reaction time or MFT data

  5. An isometric muscle force estimation framework based on a high-density surface EMG array and an NMF algorithm

    Science.gov (United States)

    Huang, Chengjun; Chen, Xiang; Cao, Shuai; Qiu, Bensheng; Zhang, Xu

    2017-08-01

    Objective. To realize accurate muscle force estimation, a novel framework is proposed in this paper which can extract the input of the prediction model from the appropriate activation area of the skeletal muscle. Approach. Surface electromyographic (sEMG) signals from the biceps brachii muscle during isometric elbow flexion were collected with a high-density (HD) electrode grid (128 channels) and the external force at three contraction levels was measured at the wrist synchronously. The sEMG envelope matrix was factorized into a matrix of basis vectors with each column representing an activation pattern and a matrix of time-varying coefficients by a nonnegative matrix factorization (NMF) algorithm. The activation pattern with the highest activation intensity, which was defined as the sum of the absolute values of the time-varying coefficient curve, was considered as the major activation pattern, and its channels with high weighting factors were selected to extract the input activation signal of a force estimation model based on the polynomial fitting technique. Main results. Compared with conventional methods using the whole channels of the grid, the proposed method could significantly improve the quality of force estimation and reduce the electrode number. Significance. The proposed method provides a way to find proper electrode placement for force estimation, which can be further employed in muscle heterogeneity analysis, myoelectric prostheses and the control of exoskeleton devices.

  6. Reorganised force control in elbow pain patients during isometric wrist extension

    DEFF Research Database (Denmark)

    Mista, Christian Ariel; Monterde, Sonia; Inglés, Montserrat

    2018-01-01

    INTRODUCTION: Reorganised force control may be an important adaptation following painful traumas. In this study, force control adaptations were assessed in elbow pain patients. Increasing the contraction demand may overcome pain interference on the motor control and as such act as an internal...... voluntary contraction. Pressure pain thresholds were recorded at the lateral epicondyle and tibialis anterior muscle. Contraction force was recorded using a three-directional force transducer. Participants performed contractions according with visual feedback of the task-related force intensity (main...... direction of wrist extension) and another set of contractions with feedback of the three force directions. Going from the simple to the detailed force feedback will increase the demand of the motor task. Force steadiness in all 3 dimensions and force direction was extracted. RESULTS: Compared with controls...

  7. Force generation by titin folding.

    Science.gov (United States)

    Mártonfalvi, Zsolt; Bianco, Pasquale; Naftz, Katalin; Ferenczy, György G; Kellermayer, Miklós

    2017-07-01

    Titin is a giant protein that provides elasticity to muscle. As the sarcomere is stretched, titin extends hierarchically according to the mechanics of its segments. Whether titin's globular domains unfold during this process and how such unfolded domains might contribute to muscle contractility are strongly debated. To explore the force-dependent folding mechanisms, here we manipulated skeletal-muscle titin molecules with high-resolution optical tweezers. In force-clamp mode, after quenching the force (force trace contained rapid fluctuations and a gradual increase of average force, indicating that titin can develop force via dynamic transitions between its structural states en route to the native conformation. In 4 M urea, which destabilizes H-bonds hence the consolidated native domain structure, the net force increase disappeared but the fluctuations persisted. Thus, whereas net force generation is caused by the ensemble folding of the elastically-coupled domains, force fluctuations arise due to a dynamic equilibrium between unfolded and molten-globule states. Monte-Carlo simulations incorporating a compact molten-globule intermediate in the folding landscape recovered all features of our nanomechanics results. The ensemble molten-globule dynamics delivers significant added contractility that may assist sarcomere mechanics, and it may reduce the dissipative energy loss associated with titin unfolding/refolding during muscle contraction/relaxation cycles. © 2017 The Protein Society.

  8. Clinical significance of isometric bite force versus electrical activity in temporal and masseter muscles

    DEFF Research Database (Denmark)

    Bakke, Merete; Michler, L; Han, K

    1989-01-01

    significant with respect to unilateral, but not to bilateral force measurements. Only in the masseter muscle was strength of dynamic contractions during chewing significantly correlated to bite force. With the present method it was demonstrated that unilateral bite force is a simple clinical indicator...

  9. A novel three-filament model of force generation in eccentric contraction of skeletal muscles.

    Directory of Open Access Journals (Sweden)

    Gudrun Schappacher-Tilp

    Full Text Available We propose and examine a three filament model of skeletal muscle force generation, thereby extending classical cross-bridge models by involving titin-actin interaction upon active force production. In regions with optimal actin-myosin overlap, the model does not alter energy and force predictions of cross-bridge models for isometric contractions. However, in contrast to cross-bridge models, the three filament model accurately predicts history-dependent force generation in half sarcomeres for eccentric and concentric contractions, and predicts the activation-dependent forces for stretches beyond actin-myosin filament overlap.

  10. Dynamical signatures of isometric force control as a function of age, expertise, and task constraints.

    Science.gov (United States)

    Vieluf, Solveig; Sleimen-Malkoun, Rita; Voelcker-Rehage, Claudia; Jirsa, Viktor; Reuter, Eva-Maria; Godde, Ben; Temprado, Jean-Jacques; Huys, Raoul

    2017-07-01

    From the conceptual and methodological framework of the dynamical systems approach, force control results from complex interactions of various subsystems yielding observable behavioral fluctuations, which comprise both deterministic (predictable) and stochastic (noise-like) dynamical components. Here, we investigated these components contributing to the observed variability in force control in groups of participants differing in age and expertise level. To this aim, young (18-25 yr) as well as late middle-aged (55-65 yr) novices and experts (precision mechanics) performed a force maintenance and a force modulation task. Results showed that whereas the amplitude of force variability did not differ across groups in the maintenance tasks, in the modulation task it was higher for late middle-aged novices than for experts and higher for both these groups than for young participants. Within both tasks and for all groups, stochastic fluctuations were lowest where the deterministic influence was smallest. However, although all groups showed similar dynamics underlying force control in the maintenance task, a group effect was found for deterministic and stochastic fluctuations in the modulation task. The latter findings imply that both components were involved in the observed group differences in the variability of force fluctuations in the modulation task. These findings suggest that between groups the general characteristics of the dynamics do not differ in either task and that force control is more affected by age than by expertise. However, expertise seems to counteract some of the age effects. NEW & NOTEWORTHY Stochastic and deterministic dynamical components contribute to force production. Dynamical signatures differ between force maintenance and cyclic force modulation tasks but hardly between age and expertise groups. Differences in both stochastic and deterministic components are associated with group differences in behavioral variability, and observed behavioral

  11. Reference values for isometric muscle force among workers for the Netherlands: a comparison of reference values

    NARCIS (Netherlands)

    Michiel Reneman; W.P. Krijnen; Dr. C.P. van der Schans; K.W. Douma; Remko Soer

    2014-01-01

    Background: Muscle force is important for daily life and sports and can be measured with a handheld dynamometer. Reference values are employed to quantify a subject’s muscle force. It is not unambiguous whether reference values can be generalized to other populations. Objectives in this study were;

  12. The Efficacy of Wrestling-Style Compression Suits to Improve Maximum Isometric Force and Movement Velocity in Well-Trained Male Rugby Athletes

    Directory of Open Access Journals (Sweden)

    Daniel T. McMaster

    2017-11-01

    Full Text Available Purpose: The prevalence of compression garment (CG use is increasing with athletes striving to take advantage of the purported benefits to recovery and performance. Here, we investigated the effect of CG on muscle force and movement velocity performance in athletes.Methods: Ten well-trained male rugby athletes wore a wrestling-style CG suit applying 13–31 mmHg of compressive pressure during a training circuit in a repeated-measures crossover design. Force and velocity data were collected during a 5-s isometric mid-thigh pull (IMTP and repeated countermovement jump (CMJ, respectively; and time to complete a 5-m horizontal loaded sled push was also measured.Results: IMTP peak force was enhanced in the CG condition by 139 ± 142 N (effect size [ES] = 0.36. Differences in CMJ peak velocity (ES = 0.08 and loaded sled-push sprint time between the conditions were trivial (ES = −0.01. A qualitative assessment of the effects of CG wear suggested that the likelihood of harm was unlikely in the CMJ and sled push, while a beneficial effect in the CMJ was possible, but not likely. Half of the athletes perceived a functional benefit in the IMTP and CMJ exercises.Conclusion: Consistent with other literature, there was no substantial effect of wearing a CG suit on CMJ and sprint performance. The improvement in peak force generation capability in an IMTP may be of benefit to rugby athletes involved in scrummaging or lineout lifting. The mechanism behind the improved force transmission is unclear, but may involve alterations in neuromuscular recruitment and proprioceptive feedback.

  13. The Efficacy of Wrestling-Style Compression Suits to Improve Maximum Isometric Force and Movement Velocity in Well-Trained Male Rugby Athletes.

    Science.gov (United States)

    McMaster, Daniel T; Beaven, Christopher M; Mayo, Brad; Gill, Nicholas; Hébert-Losier, Kim

    2017-01-01

    Purpose: The prevalence of compression garment (CG) use is increasing with athletes striving to take advantage of the purported benefits to recovery and performance. Here, we investigated the effect of CG on muscle force and movement velocity performance in athletes. Methods: Ten well-trained male rugby athletes wore a wrestling-style CG suit applying 13-31 mmHg of compressive pressure during a training circuit in a repeated-measures crossover design. Force and velocity data were collected during a 5-s isometric mid-thigh pull (IMTP) and repeated countermovement jump (CMJ), respectively; and time to complete a 5-m horizontal loaded sled push was also measured. Results: IMTP peak force was enhanced in the CG condition by 139 ± 142 N (effect size [ES] = 0.36). Differences in CMJ peak velocity (ES = 0.08) and loaded sled-push sprint time between the conditions were trivial (ES = -0.01). A qualitative assessment of the effects of CG wear suggested that the likelihood of harm was unlikely in the CMJ and sled push, while a beneficial effect in the CMJ was possible, but not likely. Half of the athletes perceived a functional benefit in the IMTP and CMJ exercises. Conclusion: Consistent with other literature, there was no substantial effect of wearing a CG suit on CMJ and sprint performance. The improvement in peak force generation capability in an IMTP may be of benefit to rugby athletes involved in scrummaging or lineout lifting. The mechanism behind the improved force transmission is unclear, but may involve alterations in neuromuscular recruitment and proprioceptive feedback.

  14. Contribution of the Cerebellum in Cue-Dependent Force Changes During an Isometric Precision Grip Task.

    Science.gov (United States)

    Kutz, Dieter F; Schmid, Barbara C; Meindl, Tobias; Timmann, Dagmar; Kolb, Florian P

    2016-08-01

    The "raspberry task" represents a precision grip task that requires continuous adjustment of grip forces and pull forces. During this task, subjects use a specialised grip rod and have to increase the pull force linearly while the rod is locked. The positions of the fingers are unrestrained and freely selectable. From the finger positions and the geometry of the grip rod, a physical lever was derived which is a comprehensive measurement of the subject's grip behaviour. In this study, the involvement of the cerebellum in establishing cued force changes (CFC) was examined. The auditory stimulus was associated with a motor behaviour that has to be readjusted during an ongoing movement that already started. Moreover, cerebellar involvement on grip behaviour was examined. The results show that patients presenting with degenerating cerebellar disease (CBL) were able to elicit CFC and were additionally able to optimise grip behaviour by minimising the lever. Comparison of the results of CBL with a control group of healthy subjects showed, however, that the CFC incidence was significantly lower and the reduction of the lever was less in CBL. Hence, the cerebellum is involved not only in the classical conditioning of reflexes but also in the association of sensory stimuli with complex changes in motor behaviour. Furthermore, the cerebellum is involved in the optimisation of grip behaviour during ongoing movements. Recent studies lead to the assumption that the cerebello-reticulo-spinal pathway might be important for the reduced optimisation of grip behaviour in CBL.

  15. The effect of signal acquisition and processing choices on ApEn values: towards a "gold standard" for distinguishing effort levels from isometric force records.

    Science.gov (United States)

    Forrest, Sarah M; Challis, John H; Winter, Samantha L

    2014-06-01

    Approximate entropy (ApEn) is frequently used to identify changes in the complexity of isometric force records with ageing and disease. Different signal acquisition and processing parameters have been used, making comparison or confirmation of results difficult. This study determined the effect of sampling and parameter choices by examining changes in ApEn values across a range of submaximal isometric contractions of the first dorsal interosseus. Reducing the sample rate by decimation changed both the value and pattern of ApEn values dramatically. The pattern of ApEn values across the range of effort levels was not sensitive to the filter cut-off frequency, or the criterion used to extract the section of data for analysis. The complexity increased with increasing effort levels using a fixed 'r' value (which accounts for measurement noise) but decreased with increasing effort level when 'r' was set to 0.1 of the standard deviation of force. It is recommended isometric force records are sampled at frequencies >200Hz, template length ('m') is set to 2, and 'r' set to measurement system noise or 0.1SD depending on physiological process to be distinguished. It is demonstrated that changes in ApEn across effort levels are related to changes in force gradation strategy. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Effects of experimental muscle pain on force variability during task-related and three directional isometric force task

    DEFF Research Database (Denmark)

    Mista, Christian Ariel; Graven-Nielsen, Thomas

    2013-01-01

    was measured using sample entropy (SEn). Three-way repeated measures ANOVA with factors level of contraction, pain/control, and time were performed for the CV, the CoP, and the SEn of each component of the force. In the tangential forces, no significant effects were found for the 3D matching tasks. The ANOVA.......05). In the task-related force, no significant effects were found for the CV during the three-dimensional task or for the task-related task. Finally, the ANOVA analysis of sample entropy showed a significant interaction between pain/control and time (P

  17. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    NARCIS (Netherlands)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to

  18. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    NARCIS (Netherlands)

    Douma, Rob; Regterschot, G.R.H.; Krijnen, Wim; Slager, Geranda; van der Schans, Cees; Zijlstra, W.

    2016-01-01

    Background: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to

  19. EMGD-FE: an open source graphical user interface for estimating isometric muscle forces in the lower limb using an EMG-driven model.

    Science.gov (United States)

    Menegaldo, Luciano Luporini; de Oliveira, Liliam Fernandes; Minato, Kin K

    2014-04-04

    This paper describes the "EMG Driven Force Estimator (EMGD-FE)", a Matlab® graphical user interface (GUI) application that estimates skeletal muscle forces from electromyography (EMG) signals. Muscle forces are obtained by numerically integrating a system of ordinary differential equations (ODEs) that simulates Hill-type muscle dynamics and that utilises EMG signals as input. In the current version, the GUI can estimate the forces of lower limb muscles executing isometric contractions. Muscles from other parts of the body can be tested as well, although no default values for model parameters are provided. To achieve accurate evaluations, EMG collection is performed simultaneously with torque measurement from a dynamometer. The computer application guides the user, step-by-step, to pre-process the raw EMG signals, create inputs for the muscle model, numerically integrate the ODEs and analyse the results. An example of the application's functions is presented using the quadriceps femoris muscle. Individual muscle force estimations for the four components as well the knee isometric torque are shown. The proposed GUI can estimate individual muscle forces from EMG signals of skeletal muscles. The estimation accuracy depends on several factors, including signal collection and modelling hypothesis issues.

  20. Effects of hand configuration on muscle force coordination, co-contraction and concomitant intermuscular coupling during maximal isometric flexion of the fingers.

    Science.gov (United States)

    Charissou, Camille; Amarantini, David; Baurès, Robin; Berton, Eric; Vigouroux, Laurent

    2017-11-01

    The mechanisms governing the control of musculoskeletal redundancy remain to be fully understood. The hand is highly redundant, and shows different functional role of extensors according to its configuration for a same functional task of finger flexion. Through intermuscular coherence analysis combined with hand musculoskeletal modelling during maximal isometric hand contractions, our aim was to better understand the neural mechanisms underlying the control of muscle force coordination and agonist-antagonist co-contraction. Thirteen participants performed maximal isometric flexions of the fingers in two configurations: power grip (Power) and finger-pressing on a surface (Press). Hand kinematics and force/moment measurements were used as inputs in a musculoskeletal model of the hand to determine muscular tensions and co-contraction. EMG-EMG coherence analysis was performed between wrist and finger flexors and extensor muscle pairs in alpha, beta and gamma frequency bands. Concomitantly with tailored muscle force coordination and increased co-contraction between Press and Power (mean difference: 48.08%; p force coordination during hand contractions. Our results highlight the functional importance of intermuscular coupling as a mechanism contributing to the control of muscle force synergies and agonist-antagonist co-contraction.

  1. Computer-Controlled Force Generator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — TDA Research, Inc. is developing a compact, low power, Next-Generation Exercise Device (NGRED) that can generate any force between 5 and 600 lbf. We use a closed...

  2. Comparison of the Hang High-Pull and Loaded Jump Squat for the Development of Vertical Jump and Isometric Force-Time Characteristics.

    Science.gov (United States)

    Oranchuk, Dustin J; Robinson, Tracey L; Switaj, Zachary J; Drinkwater, Eric J

    2017-04-15

    Weightlifting movements have high skill demands and require expert coaching. Loaded jumps have a comparably lower skill demand, but may be similarly effective for improving explosive performance. The purpose of this study was to compare vertical jump performance, isometric force, and rate of force development (RFD) following a ten-week intervention employing the hang high-pull (hang-pull) or trap-bar jump squat (jump-squat). Eighteen NCAA Division II swimmers (8 males, 10 females) with at least one year of resistance training experience volunteered to participate. Testing included the squat jump (SJ), countermovement jump (CMJ) and the isometric mid-thigh pull (IMTP). Vertical ground reaction forces were analyzed to obtain jump height and relative peak power. Relative peak force, peak RFD and relative force at five time bands were obtained from the IMTP. Subjects were randomly assigned to either a hang-pull (n = 9) or jump-squat (n = 9) training group and completed a ten-week, volume-equated, periodized training program. While there was a significant main effect of training for both groups, no statistically significant between-group differences were found (p ≥ 0.17) for any of the dependent variables. However, medium effect sizes in favor of the jump-squat training group were seen in SJ height (d = 0.56) and SJ peak power (d = 0.69). Loaded jumps seem equally effective as weightlifting derivatives for improving lower-body power in experienced athletes. Since loaded jumps require less skill and less coaching expertise than weightlifting, loaded jumps should be considered where coaching complex movements is difficult.

  3. Sexual dimorphism of extensor carpi radialis muscle size, isometric force, relaxation rate and stamina during the breeding season of the frog Rana temporaria Linnaeus 1758.

    Science.gov (United States)

    Navas, Carlos A; James, Rob S

    2007-02-01

    Mating success of individual male frogs within explosive breeding species can depend on their ability to compete for a mate and to hold onto that mate during amplexus. Such importance of amplexus has resulted in the evolution of sexual dimorphism in the morphology and contractile characteristics of the anuran forelimb muscles used during amplexus. The aims of our study were to use an explosive breeding frog (Rana temporaria) during the breeding season to compare extensor carpi radialis (ECR) muscle length, mass, isometric activation times, relaxation times, absolute force, relative force (stress) and fatigue between male and female frogs. We found that ECR muscle mass and length were greater (tenfold and 1.4-fold, respectively), absolute tetanic muscle force and relative tetanic force (stress) were greater (16-fold and 2.2-fold, respectively) and relaxation times were slower in males than in females. Male ECR muscles incompletely relaxed during fatigue tests and showed less fatigue than female muscles. These sex differences are likely to be beneficial to the male frogs in allowing them to produce relatively high absolute muscle forces for prolonged periods of time to hold onto their mate during amplexus.

  4. Fluctuations in isometric muscle force can be described by one linear projection of low-frequency components of motor unit discharge rates.

    Science.gov (United States)

    Negro, Francesco; Holobar, Ales; Farina, Dario

    2009-12-15

    The aim of the study was to investigate the relation between linear transformations of motor unit discharge rates and muscle force. Intramuscular (wire electrodes) and high-density surface EMG (13 x 5 electrode grid) were recorded from the abductor digiti minimi muscle of eight healthy men during 60 s contractions at 5%, 7.5% and 10% of the maximal force. Spike trains of a total of 222 motor units were identified from the EMG recordings with decomposition algorithms. Principal component analysis of the smoothed motor unit discharge rates indicated that one component (first common component, FCC) described 44.2 +/- 7.5% of the total variability of the smoothed discharge rates when computed over the entire contraction interval and 64.3 +/- 10.2% of the variability when computed over 5 s intervals. When the FCC was computed from four or more motor units per contraction, it correlated with the force produced by the muscle (62.7 +/- 10.1%) by a greater degree (P FCC and the force signal increased up to 71.8 +/- 13.1% when the duration and the shape of the smoothing window for discharge rates were similar to the average motor unit twitch force. Moreover, the coefficients of variation (CoV) for the force and for the FCC signal were correlated in all subjects (R(2) range = 0.14-0.56; P measures on the tibialis anterior muscle of an additional eight subjects during contractions at forces up to 20% of the maximal force (e.g. FCC explained 59.8 +/- 11.0% of variability of the smoothed discharge rates). In conclusion, one signal captures most of the underlying variability of the low-frequency components of motor unit discharge rates and explains large part of the fluctuations in the motor output during isometric contractions.

  5. Effects of combined and classic training on different isometric rate of force development parameters of leg extensors in female volleyball players: Discriminative analysis approach

    Directory of Open Access Journals (Sweden)

    Rajić Branislav

    2013-01-01

    Full Text Available Background: The aim of this study is to verify the effects of the combined and classic training of different isometric rates of force development (RFD parameters of legs. Materials and Methods: Three groups of female athletes was tested: Experimental group (N = 12, classically trained group (N = 11, and control group (N = 20 of athletes. The isometric "standing leg extension" and "Rise on Toes" tests were conducted to evaluate the maximal force, time necessary time to reach it and the RFD analyzed at 100 ms, 180 ms, 250 ms from the onset, and 50-100% of its maximal result. Results: The maximal RFD of legs and calves are dominant explosive parameters. Special training enhanced the RFD of calves of GROUP SPEC at 100 ms (P = 0.05, at 180 ms (P = 0.039, at 250 ms (P = 0.039, at 50% of the F max (P = 0.031 and the F max (P = 0.05. Domination of GROUP SPEC toward GROUP CLASS and GROUP CONTROL is in case of legs at 100 ms (P = 0.04; at 180 ms (P = 0.04; at 250 ms (P = 0.00; at 50% of the F max (P = 0.01 and at the F max (P = 0.00; in case of calves at 100 ms (P = 0.07; 180 ms (P = 0.001; at 250 ms (P = 0.00; at 50% of the F max (P = 0.00 and at F max (P = 0.000. Conclusion: Dominant explosive factors are maximal RFD of leg extensors and calves, and legs at 250ms. Specific training enhanced explosiveness of calves of GROUP SPEC general and partial domination of GROUP SPEC by 87% over GROUP CLASS , and 35% over GROUP CONTROL .

  6. Normal isometric strength of rotator cuff muscles in adults

    OpenAIRE

    Chezar, A.; Berkovitch, Y.; Haddad, M.; Keren, Y.; Soudry, M.; Rosenberg, N.

    2013-01-01

    Objectives The most prevalent disorders of the shoulder are related to the muscles of rotator cuff. In order to develop a mechanical method for the evaluation of the rotator cuff muscles, we created a database of isometric force generation by the rotator cuff muscles in normal adult population. We hypothesised the existence of variations according to age, gender and dominancy of limb. Methods A total of 400 healthy adult volunteers were tested, classified into groups of 50 men and women for e...

  7. Do centrioles generate a polar ejection force?

    Science.gov (United States)

    Wells, Jonathan

    2005-01-01

    A microtubule-dependent polar ejection force that pushes chromosomes away from spindle poles during prometaphase is observed in animal cells but not in the cells of higher plants. Elongating microtubules and kinesin-like motor molecules have been proposed as possible causes, but neither accounts for all the data. In the hypothesis proposed here a polar ejection force is generated by centrioles, which are found in animals but not in higher plants. Centrioles consist of nine microtubule triplets arranged like the blades of a tiny turbine. Instead of viewing centrioles through the spectacles of molecular reductionism and neo-Darwinism, this hypothesis assumes that they are holistically designed to be turbines. Orthogonally oriented centriolar turbines could generate oscillations in spindle microtubules that resemble the motion produced by a laboratory vortexer. The result would be a microtubule-mediated ejection force tending to move chromosomes away from the spindle axis and the poles. A rise in intracellular calcium at the onset of anaphase could regulate the polar ejection force by shutting down the centriolar turbines, but defective regulation could result in an excessive force that contributes to the chromosomal instability characteristic of most cancer cells.

  8. FMNL formins boost lamellipodial force generation

    DEFF Research Database (Denmark)

    Kage, Frieda; Winterhoff, Moritz; Dimchev, Vanessa

    2017-01-01

    , without changing patterns of Arp2/3 complex incorporation. Strikingly, in melanoma cells, FMNL2/3 gene inactivation almost completely abolishes protrusion forces exerted by lamellipodia and modifies their ultrastructural organization. Consistently, CRISPR/Cas-mediated depletion of FMNL2/3 in fibroblasts...... reduces both migration and capability of cells to move against viscous media. Together, we conclude that force generation in lamellipodia strongly depends on FMNL formin activity, operating in addition to Arp2/3 complex-dependent filament branching....

  9. Eight-week vibration training of the elbow flexors by force modulation : effects on dynamic and isometric strength

    NARCIS (Netherlands)

    Xu, L.; Cardinale, M.; Rabotti, C.; Beju, B.; Mischi, M.

    2016-01-01

    Vibration exercise (VE) has been suggested as an effective method to improve strength and power capabilities. However, the underlying mechanisms in response to VE are still unclear. A pulley-like VE system, characterized by sinusoidal force applications has been developed and tested for proof of

  10. Changes in ipsilateral motor cortex activity during a unilateral isometric finger task are dependent on the muscle contraction force

    International Nuclear Information System (INIS)

    Shibuya, Kenichi; Kuboyama, Naomi; Tanaka, Junya

    2014-01-01

    It is possible to examine bilateral primary motor cortex (M1) activation during a sustained motor task using near-infrared spectroscopy (NIRS), in which it is assumed that increased oxygenation reflects cortical activation. The purpose of this study was to examine bilateral M1 activation in response to graded levels of force production during a unilateral finger task. Ten healthy right-handed male subjects participated in this study. NIRS probes were placed over the cortex to measure M1 activity while the subjects performed the finger task. The subjects performed a 10 s finger task at 20%, 40%, and 60% of the maximal voluntary contraction (MVC). Symmetrical activation was found over both M1 areas at all force levels investigated. In the contralateral M1, there were significant differences in oxygenation between 20% and 60% MVC, as well as between 40% and 60% MVC. In the ipsilateral M1, there were significant differences among all force levels. These results indicate the ipsilateral M1 takes part in muscle force control. (paper)

  11. Steam generator of the forced circulation type

    International Nuclear Information System (INIS)

    Forestier, Jean; Leblanc, Bernard; Monteil, Marcel; Monteil, Pierre

    1977-01-01

    The steam generator described is of the forced circulation single passage type comprising an outer casing including a vertical generally cylindrical side ring, an internal skirt coaxial with the outer casing, the bottom of this skirt having a free edge separated from a bottom end closing the outer casing, a central tube plate extending horizontally near a top end, in opposition to the bottom end, a peripheral tube plate, parallel to the central plate and located in the annular space under this central plate, a bundle of J shaped tubes [fr

  12. A vacuum--generated inertia reaction force

    International Nuclear Information System (INIS)

    Rueda, Alfonso; Haisch, Bernard

    2001-01-01

    A clear and succinct covariant approach shows that, in principle, there must be a contribution to the inertia reaction force on an accelerated object by the surrounding vacuum electromagnetic field in which the object is embedded. No details of the vacuum to object electromagnetic interaction need to be specified other than the fact that the object is made of electromagnetically interacting particles. Some interesting consequences of this feature are discussed. This analysis strongly supports the concept that inertia is indeed an opposition of the vacuum fields to any attempt to change the uniform state of motion of material bodies. This also definitely shows that inertia should be viewed as extrinsic to mass and that causing agents and/or mechanisms responsible for the inertia reaction force are neither intrinsic to the notion of mass nor to the entities responsible for the existence of mass in elementary particles (as, e.g., the Higgs field). In other words the mechanism that produces the inertia-reaction-force requires an explicit explanation. This explicit explanation is that inertia is an opposition of the vacuum fields to the accelerated motion of any material entities, i.e., of entities that possess mass. It is briefly commented why the existence of a Higgs field responsible for the generation of mass in elementary particles does not contradict the view presented here. It is also briefly discussed why a strict version of Mach's Principle does really contradict this view, though a broad sense version of Mach's Principle may be in agreement

  13. Effect of combined actions of hip adduction/abduction on the force generation and maintenance of pelvic floor muscles in healthy women.

    Directory of Open Access Journals (Sweden)

    Amanda C Amorim

    Full Text Available Pelvic floor muscle (PFM force and coordination are related to urinary incontinence severity and to sexual satisfaction. Health professionals frequently combine classic PFM exercises with hip adduction/abduction contraction to treat these disorders, but the real benefits of this practice are still unknown. Based on a theoretical anatomy approach whereby the levator ani muscle is inserted into the obturator internus myofascia and in which force generated by hip movements should increase the contraction quality of PFMs, our aim was to investigate the effects of isometric hip adduction and abduction on PFM force generation. Twenty healthy, nulliparous women were evaluated using two strain-gauge dynamometers (one cylinder-like inside the vaginal cavity, and the other measuring hip adduction/abduction forces around both thighs while performing three different tasks: (a isolated PFM contraction; (b PFM contraction combined with hip adduction (30% and 50% maximum hip force; and (c PFM contraction combined with hip abduction (30% and 50% maximum hip force. Data were sampled at 100Hz and subtracted from the offset if existent. We calculated a gradient between the isolated PFM contraction and each hip condition (Δ Adduction and Δ Abduction for all variables: Maximum force (N, instant of maximum-force occurrence (s, mean force in an 8-second window (N, and PFM force loss (N.s. We compared both conditions gradients in 30% and 50% by paired t-tests. All variables did not differ between hip conditions both in 30% and 50% of maximum hip force (p>.05. PFM contraction combined with isometric hip abduction did not increase vaginal force in healthy and nulliparous women compared to PFM contraction combined with isometric hip adduction. Therefore, so far, the use of hip adduction or abduction in PFM training and treatments are not justified for improving PFM strength and endurance.

  14. Curvature recognition and force generation in phagocytosis

    Directory of Open Access Journals (Sweden)

    Prassler Jana

    2010-12-01

    Full Text Available Abstract Background The uptake of particles by actin-powered invagination of the plasma membrane is common to protozoa and to phagocytes involved in the immune response of higher organisms. The question addressed here is how a phagocyte may use geometric cues to optimize force generation for the uptake of a particle. We survey mechanisms that enable a phagocyte to remodel actin organization in response to particles of complex shape. Results Using particles that consist of two lobes separated by a neck, we found that Dictyostelium cells transmit signals concerning the curvature of a surface to the actin system underlying the plasma membrane. Force applied to a concave region can divide a particle in two, allowing engulfment of the portion first encountered. The phagosome membrane that is bent around the concave region is marked by a protein containing an inverse Bin-Amphiphysin-Rvs (I-BAR domain in combination with an Src homology (SH3 domain, similar to mammalian insulin receptor tyrosine kinase substrate p53. Regulatory proteins enable the phagocyte to switch activities within seconds in response to particle shape. Ras, an inducer of actin polymerization, is activated along the cup surface. Coronin, which limits the lifetime of actin structures, is reversibly recruited to the cup, reflecting a program of actin depolymerization. The various forms of myosin-I are candidate motor proteins for force generation in particle uptake, whereas myosin-II is engaged only in retracting a phagocytic cup after a switch to particle release. Thus, the constriction of a phagocytic cup differs from the contraction of a cleavage furrow in mitosis. Conclusions Phagocytes scan a particle surface for convex and concave regions. By modulating the spatiotemporal pattern of actin organization, they are capable of switching between different modes of interaction with a particle, either arresting at a concave region and applying force in an attempt to sever the particle

  15. Effect of Elastase-induced Emphysema on the Force-generating Ability of the Diaphragm

    Science.gov (United States)

    Supinski, Gerald S.; Kelsen, Steven G.

    1982-01-01

    The effect of emphysema on the ability of the diaphragm to generate force was examined in costal diaphragm muscle strips from 10 Golden hamsters killed 18 mo after intratracheal injection of pancreatic elastase in a dose producing hyperinflation (mean total lung capacity [TLC] = 163% of control) and generalized panacinar emphysema. 13 saline-injected normal animals served as controls. The time course of isometric tension and the effect of alterations in muscle fiber and sarcomere length on the isometric tension (T) generated in response to tetanizing electrical stimuli (length-tension [L-T] relationship) were examined. Elastase administration caused an increase in diaphragm muscle thickness and reduction in the length of costal diaphragm muscle fibers measured in situ. Emphysema significantly increased the maximum tetanic tension as a result of hypertrophy. Maximal tension corrected for increases in muscle cross-sectional area (T/cm2), however, was the same in emphysematous (E) and control (C) animals. Emphysema also shifted the muscle fiber L-T curve of the diaphragm but not of a control muscle, the soleus, toward shorter lengths. In contrast to the effects of E on the diaphragm muscle fiber L-T curve, the sarcomere L-T curve was the same in E and C. Since the length at which tension was maximal correlated closely with sarcomere number (r = 0.94; P < 0.001) reduction in the number of sarcomeres in series in muscles from emphysematous animals appeared to explain the shift in the muscle fiber L-T curve. We conclude that in elastase-induced emphysema adaptive changes both in diaphragm cross-sectional area and sarcomere number augment the force-generating ability of the diaphragm. We speculate that changes in sarcomere number compensate for alterations in muscle fiber length resulting from chronic hyperinflation of the thorax, while diaphragmatic muscle hypertrophy represents a response to changes in respiratory load and/or diaphragm configuration (La

  16. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  17. Normal isometric strength of rotatorcuff muscles in adults.

    Science.gov (United States)

    Chezar, A; Berkovitch, Y; Haddad, M; Keren, Y; Soudry, M; Rosenberg, N

    2013-01-01

    The most prevalent disorders of the shoulder are related to the muscles of rotator cuff. In order to develop a mechanical method for the evaluation of the rotator cuff muscles, we created a database of isometric force generation by the rotator cuff muscles in normal adult population. We hypothesised the existence of variations according to age, gender and dominancy of limb. A total of 400 healthy adult volunteers were tested, classified into groups of 50 men and women for each decade of life. Maximal isometric force was measured at standardised positions for supraspinatus, infraspinatus and subscapularis muscles in both shoulders in every person. Torque of the force was calculated and normalised to lean body mass. The profiles of mean torque-time curves for each age and gender group were compared. Our data showed that men gradually gained maximal strength in the fifth decade, and showed decreased strength in the sixth. In women the maximal strength was gained in the fourth decade with gradual decline to the sixth decade of life. The dominant arm was stronger in most of the tested groups. The torque profiles of the rotator cuff muscles in men at all ages were significantly higher than that in women. We found previously unrecognised variations of rotator cuff muscles' isometric strength according to age, gender and dominancy in a normal population. The presented data may serve as a basis for the future studies for identification of the abnormal patterns of muscle isometric strength in patients with pathology of the rotator cuff muscles. Cite this article: Bone Joint Res 2013;2:214-19.

  18. Voluntary drive-dependent changes in vastus lateralis motor unit firing rates during a sustained isometric contraction at 50% of maximum knee extension force.

    NARCIS (Netherlands)

    de Ruiter, C.J.; Elzinga, M.J.; Verdijk, PW; van Mechelen, W.; de Haan, A.

    2004-01-01

    The purpose of the present study was to relate the expected inter-subject variability in voluntary drive of the knee extensor muscles during a sustained isometric contraction to the changes in firing rates of single motor units. Voluntary activation, as established with super-imposed electrical

  19. Cervical isometric strength and range of motion of elite rugby union players: a cohort study.

    Science.gov (United States)

    Hamilton, David F; Gatherer, Don

    2014-01-01

    Head and neck injury is relatively common in Rugby Union. Despite this, strength and range-of-motion characteristics of the cervical spine are poorly characterised. The aim of this study was to provide data on the strength and range-of-motion of the cervical spine of professional rugby players to guide clinical rehabilitation. A cohort study was performed evaluating 27 players from a single UK professional rugby club. Cervical isometric strength and range-of-motion were assessed in 3 planes of reference. Anthropometric data was collected and multivariate regression modelling performed with a view to predicting cervical isometric strength. Largest forces were generated in extension, with broadly equal isometric side flexion forces at around 90% of extension values. The forwards generated significantly more force than the backline in all parameters bar flexion. The forwards had substantially reduced cervical range-of-motion and larger body mass, with differences observed in height, weight, neck circumference and chest circumference (p isometric extension (adjusted R(2) = 30.34). Rehabilitative training programs aim to restore individuals to pre-injury status. This work provides reference ranges for the strength and range of motion of the cervical spine of current elite level rugby players.

  20. Isometric exercise (image)

    Science.gov (United States)

    Isometric exercise works muscles and strengthens bone. Increased muscle mass elevates metabolism, which in turn burns fat. Strength training is also called anaerobic exercise, as opposed to aerobic, because increased oxygen production is not ...

  1. Generation of synthetic surface electromyography signals under fatigue conditions for varying force inputs using feedback control algorithm.

    Science.gov (United States)

    Venugopal, G; Deepak, P; Ghosh, Diptasree M; Ramakrishnan, S

    2017-11-01

    Surface electromyography is a non-invasive technique used for recording the electrical activity of neuromuscular systems. These signals are random, complex and multi-component. There are several techniques to extract information about the force exerted by muscles during any activity. This work attempts to generate surface electromyography signals for various magnitudes of force under isometric non-fatigue and fatigue conditions using a feedback model. The model is based on existing current distribution, volume conductor relations, the feedback control algorithm for rate coding and generation of firing pattern. The result shows that synthetic surface electromyography signals are highly complex in both non-fatigue and fatigue conditions. Furthermore, surface electromyography signals have higher amplitude and lower frequency under fatigue condition. This model can be used to study the influence of various signal parameters under fatigue and non-fatigue conditions.

  2. Pump instability phenomena generated by fluid forces

    Science.gov (United States)

    Gopalakrishnan, S.

    1985-01-01

    Rotor dynamic behavior of high energy centrifugal pumps is significantly affected by two types of fluid forces; one due to the hydraulic interaction of the impeller with the surrounding volute or diffuser and the other due to the effect of the wear rings. The available data on these forces is first reviewed. A simple one degree-of-freedom system containing these forces is analytically solved to exhibit the rotor dynamic effects. To illustrate the relative magnitude of these phenomena, an example of a multistage boiler feed pump is worked out. It is shown that the wear ring effects tend to suppress critical speed and postpone instability onset. But the volute-impeller forces tend to lower the critical speed and the instability onset speed. However, for typical boiler feed pumps under normal running clearances, the wear ring effects are much more significant than the destabilizing hydraulic interaction effects.

  3. A three-dimensional computerized isometric strength measurement system.

    Science.gov (United States)

    Black, Nancy L; Das, Biman

    2007-05-01

    The three-dimensional Computerized Isometric Strength Measurement System (CISMS) reliably and accurately measures isometric pull and push strengths in work spaces of paraplegic populations while anticipating comparative studies with other populations. The main elements of the system were: an extendable arm, a vertical supporting track, a rotating platform, a force transducer, stability sensors and a computerized data collection interface. The CISMS with minor modification was successfully used to measure isometric push-up and pull-down strengths of paraplegics and isometric push, pull, push-up and pull-down strength in work spaces for seated and standing able-bodied populations. The instrument has satisfied criteria of versatility, safety and comfort, ease of operation, and durability. Results are accurate within 2N for aligned forces. Costing approximately $1,500 (US) including computer, the system is affordable and accurate for aligned isometric strength measurements.

  4. Relationship between isometric and dynamic strength in recreationally trained men.

    Science.gov (United States)

    McGuigan, Michael R; Newton, Michael J; Winchester, Jason B; Nelson, Arnold G

    2010-09-01

    The purpose of this investigation was to examine the relationships between measures of maximal isometric force (peak force [PF]), rate of force development (RFD), vertical jump performance (VJ) and 1-repetition maximum (1RM) strength in recreationally trained men. The subjects in this study were 26 men ([mean +/- SD]: age 22 +/- 1 years; height 175 +/- 7 cm; mass 90 +/- 10 kg). They were tested for PF using the isometric midthigh pull exercise. The 1RM for the squat and bench press exercise were determined as a measure of dynamic strength. Explosive strength was measured as RFD from the isometric force-time curve. Correlations between the variables were calculated using Pearson product moment correlation coefficient. There was a nearly perfect correlation between measures of PF and 1RM squat (r = 0.97, p isometric maximum strength determined during the isometric midthigh pull test correlated well with 1RM and VJ testing. However, RFD measured during the same test did not appear to correlate as well with other measures. The isometric midthigh pull provides an efficient method for assessing strength in recreationally trained individuals. Practitioners wishing to obtain performance data related to maximum strength may wish to consider isometric testing as a less time intensive method of testing.

  5. A study on fixing force generation mechanism of ER gel

    International Nuclear Information System (INIS)

    Tanaka, H; Kakinuma, Y; Aoyama, T; Anzai, H

    2009-01-01

    Electro-rheological Gel (ERG) is a new functional elastomer which changes its surface frictional and adhesive property according to the intensity of applied electrical field. This unique property is called ERG effect. The upper sliding electrode placed on the surface of ERG is fixed by the adhesive effect of ERG under electrical field. Variable fixing forces due to adhesion are generated by this effect. However, relationship between physical factors and generated fixing force has not yet been clarified. In this study, physical mechanism of fixing phenomenon is elucidated experimentally from the view point of frictional force and adhesive force. From the results, empirical equation of generated fixing force is originally derived to establish the theory of ERG effect.

  6. A study on fixing force generation mechanism of ER gel

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, H; Kakinuma, Y; Aoyama, T [School of Integrated Design Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Anzai, H [Fujikura kasei Co., Ltd., 2-6-15 Shibakouen, Minato-ku, Tokyo (Japan)], E-mail: h-tanaka@ina.sd.keio.ac.jp

    2009-02-01

    Electro-rheological Gel (ERG) is a new functional elastomer which changes its surface frictional and adhesive property according to the intensity of applied electrical field. This unique property is called ERG effect. The upper sliding electrode placed on the surface of ERG is fixed by the adhesive effect of ERG under electrical field. Variable fixing forces due to adhesion are generated by this effect. However, relationship between physical factors and generated fixing force has not yet been clarified. In this study, physical mechanism of fixing phenomenon is elucidated experimentally from the view point of frictional force and adhesive force. From the results, empirical equation of generated fixing force is originally derived to establish the theory of ERG effect.

  7. Scaling of motor cortical excitability during unimanual force generation.

    Science.gov (United States)

    Perez, Monica A; Cohen, Leonardo G

    2009-10-01

    During performance of a unimanual force generation task primary motor cortices (M1s) experience clear functional changes. Here, we evaluated the way in which M1s interact during parametric increases in right wrist flexion force in healthy volunteers. We measured the amplitude and the slope of motor evoked potentials (MEP) recruitment curves to transcranial magnetic stimulation (TMS) in the left and right flexor carpi radialis (FCR) muscles at rest and during 10%, 30% and 70% of maximal wrist flexion force. At rest, no differences were observed in the amplitude and slope of MEP recruitment curves in the left and right FCR muscles. With increasing right wrist flexion force, MEP amplitudes increased in both FCR muscles, with larger amplitudes in the right FCR. We found a significant correlation between the left and right MEP amplitudes across conditions. The slope of right and left FCR MEP recruitment curve was significantly steeper at 70% of force compared to rest and 10% of force. A significant correlation between the slope of left and right FCR MEP amplitudes was found at 70% of force only. Our results indicate a differential scaling of excitability in the corticospinal system controlling right and left FCR muscles at increasing levels of unimanual force generation. Specifically, these data highlights that at strong levels of unimanual force the increases in motor cortical excitability with increasing TMS stimulus intensities follow a similar pattern in both M1s, while at low levels of force they do not.

  8. Flapping motion and force generation in a viscoelastic fluid

    Science.gov (United States)

    Normand, Thibaud; Lauga, Eric

    2008-12-01

    In a variety of biological situations, swimming cells have to move through complex fluids. Similarly, mucociliary clearance involves the transport of polymeric fluids by beating cilia. Here, we consider the extent to which complex fluids could be exploited for force generation on small scales. We consider a prototypical reciprocal motion (i.e., identical under time-reversal symmetry): the periodic flapping of a tethered semi-infinite plane. In the Newtonian limit, such motion cannot be used for force generation according to Purcell’s scallop theorem. In a polymeric fluid (Oldroyd-B, and its generalization), we show that this is not the case and calculate explicitly the forces on the flapper for small-amplitude sinusoidal motion. Three setups are considered: a flapper near a wall, a flapper in a wedge, and a two-dimensional scalloplike flapper. In all cases, we show that at quadratic order in the oscillation amplitude, the tethered flapping motion induces net forces, but no average flow. Our results demonstrate therefore that the scallop theorem is not valid in polymeric fluids. The reciprocal component of the movement of biological appendages such as cilia can thus generate nontrivial forces in polymeric fluid such as mucus, and normal-stress differences can be exploited as a pure viscoelastic force generation and propulsion method.

  9. Entropic elasticity in the generation of muscle Force - A theoretical model

    DEFF Research Database (Denmark)

    Nielsen, Bjørn Gilbert

    2002-01-01

    A novel simplified structural model of sarcomeric force production in striate muscle is presented. Using some simple assumptions regarding the distribution of myosin spring lengths at different sliding velocities it is possible to derive a very simple expression showing the main components...... of the experimentally observed force-velocity relationship of muscle: nonlinearity during contraction (Hill, 1938), maximal force production during stretching equal to two times the isometric force (Katz, 1939), yielding at high stretching velocity, slightly concave force-extension relationship during sudden length......-bridges are explored [linear, power function and worm-like chain (WLC) model based], and it is shown that the best results are obtained if the individual myosin-spring forces are modelled using a WLC model, thus hinting that entropic elasticity could be the main source of force in myosin undergoing the conformational...

  10. The Effects of Active Trigger Point of Upper Trapezius Muscle on Its Electromyography Activity and Maximal Isometric Contraction Force during Scapular Plane Elevation (Scaption

    Directory of Open Access Journals (Sweden)

    Zahra Mohammadi

    2014-01-01

    Full Text Available Objective: Trigger points may result in referral pain of their close areas. Recent evidence suggests that latent trigger points although they are not sensitive enough to cause pain, can interfere with the normal muscle function. These myofascial trigger points are estimated as an electro-physiological phenomenon. However, there are a few studies which investigated the effect of these points on the muscle activity. Muscle activity is a determinant factor in injuries which may cause or worsen shoulder-neck pain. The aim of the study was to evaluate upper trapezius muscle activity and delay time at the presence of active trigger point during scapular plane elevation (scaption. Materials & Methods: In a case-control comparative study in spring 2012, Seventeen women with active trigger points (mean age 26.76 y and 17 healthy women (mean age 26.18 y in bio-mechanic laboratory of University of Social Welfare and Rehabilitation sciences (USWR participated in the study. Using surface EMG, the amplitude of muscle activity and the onset time of upper trapezius during scaption, were recorded and analyzed. Results: The maximum amplitude of the upper trapezius muscle activity (during maximal voluntary isometric contraction of 90°scaption in patients showed significant decrease in comparison with the healthy subjects (P=0.01.Also, the onset time of upper trapezius muscle activation time in the patient group was significantly delayed in comparison to the healthy group (P=0.04. Conclusion: At the presence of trigger points in Upper trapezius muscle, muscle activation pattern changes trigger points can change the amplitude and timing of muscle activity and may consequently lead to abnormal patterns of motion of the shoulder girdle. These findings can be used in the prevention and treatment of shoulder disorders.

  11. Generation of spin motive force in a soliton lattice

    International Nuclear Information System (INIS)

    Ovchinnikov, A. S.; Sinitsyn, V. E.; Bostrem, I. G.; Kishine, J.

    2013-01-01

    The generation of a spin motive force in a chiral helimagnet due to the action of two crossed magnetic fields is considered. The cases of pulsed and periodic magnetic fields directed along the helical axis under a perpendicular dc field are analyzed. It is shown that, in the case of a pulsed field, the spin motive force is related to dissipation, whereas in a periodic field, there is a reactive component that is not related to damping processes.

  12. Postactivation potentiation biases maximal isometric strength assessment.

    Science.gov (United States)

    Lima, Leonardo Coelho Rabello; Oliveira, Felipe Bruno Dias; Oliveira, Thiago Pires; Assumpção, Claudio de Oliveira; Greco, Camila Coelho; Cardozo, Adalgiso Croscato; Denadai, Benedito Sérgio

    2014-01-01

    Postactivation potentiation (PAP) is known to enhance force production. Maximal isometric strength assessment protocols usually consist of two or more maximal voluntary isometric contractions (MVCs). The objective of this study was to determine if PAP would influence isometric strength assessment. Healthy male volunteers (n = 23) performed two five-second MVCs separated by a 180-seconds interval. Changes in isometric peak torque (IPT), time to achieve it (tPTI), contractile impulse (CI), root mean square of the electromyographic signal during PTI (RMS), and rate of torque development (RTD), in different intervals, were measured. Significant increases in IPT (240.6 ± 55.7 N·m versus 248.9 ± 55.1 N·m), RTD (746 ± 152 N·m·s(-1) versus 727 ± 158 N·m·s(-1)), and RMS (59.1 ± 12.2% RMSMAX  versus 54.8 ± 9.4% RMSMAX) were found on the second MVC. tPTI decreased significantly on the second MVC (2373 ± 1200 ms versus 2784 ± 1226 ms). We conclude that a first MVC leads to PAP that elicits significant enhancements in strength-related variables of a second MVC performed 180 seconds later. If disconsidered, this phenomenon might bias maximal isometric strength assessment, overestimating some of these variables.

  13. Physical Modeling of microtubule force generation and self-organization

    NARCIS (Netherlands)

    Tanase, C.

    2004-01-01

    Biological systems are complex heterogeneous and far from equilibrium systems. The fundamental questions posed by the physics of such systems are what the force generation mechanisms are, and how energy is processed and distributed among the components inside them. In answering these questions we

  14. Effects of calcium, inorganic phosphate, and pH on isometric force in single skinned cardiomyocytes from donor and failing human hearts

    NARCIS (Netherlands)

    van der Velden, J.; Klein, L. J.; Zaremba, R.; Boontje, N. M.; Huybregts, M. A.; Stooker, W.; Eijsman, L.; de Jong, J. W.; Visser, C. A.; Visser, F. C.; Stienen, G. J.

    2001-01-01

    During ischemia, the intracellular calcium and inorganic phosphate (P(i)) concentrations rise and pH falls. We investigated the effects of these changes on force development in donor and failing human hearts to determine if altered contractile protein composition during heart failure changes the

  15. Dihydrotestosterone activates the MAPK pathway and modulates maximum isometric force through the EGF receptor in isolated intact mouse skeletal muscle fibres.

    Science.gov (United States)

    Hamdi, M M; Mutungi, G

    2010-02-01

    It is generally believed that steroid hormones have both genomic and non-genomic (rapid) actions. Although the latter form an important component of the physiological response of these hormones, little is known about the cellular signalling pathway(s) mediating these effects and their physiological functions in adult mammalian skeletal muscle fibres. Therefore, the primary aim of this study was to investigate the non-genomic actions of dihydrotestosterone (DHT) and their physiological role in isolated intact mammalian skeletal muscle fibre bundles. Our results show that treating the fibre bundles with physiological concentrations of DHT increases both twitch and tetanic contractions in fast twitch fibres. However, it decreases them in slow twitch fibres. These changes in force are accompanied by an increase in the phosphorylation of MAPK/ERK1/2 in both fibre types and that of regulatory myosin light chains in fast twitch fibres. Both effects were insensitive to inhibitors of Src kinase, androgen receptor, insulin-like growth factor 1 receptor and platelet-derived growth factor receptor. However, they were abolished by the MAPK/ERK1/2 kinase inhibitor PD98059 and the epidermal growth factor (EGF) receptor inhibitor tyrphostin AG 1478. In contrast, testosterone had no effect on force and increased the phosphorylation of ERK1/2 in slow twitch fibres only. From these results we conclude that sex steroids have non-genomic actions in isolated intact mammalian skeletal muscle fibres. These are mediated through the EGF receptor and one of their main physiological functions is the enhancement of force production in fast twitch skeletal muscle fibres.

  16. Micropipette force probe to quantify single-cell force generation: application to T-cell activation.

    Science.gov (United States)

    Sawicka, Anna; Babataheri, Avin; Dogniaux, Stéphanie; Barakat, Abdul I; Gonzalez-Rodriguez, David; Hivroz, Claire; Husson, Julien

    2017-11-07

    In response to engagement of surface molecules, cells generate active forces that regulate many cellular processes. Developing tools that permit gathering mechanical and morphological information on these forces is of the utmost importance. Here we describe a new technique, the micropipette force probe, that uses a micropipette as a flexible cantilever that can aspirate at its tip a bead that is coated with molecules of interest and is brought in contact with the cell. This technique simultaneously allows tracking the resulting changes in cell morphology and mechanics as well as measuring the forces generated by the cell. To illustrate the power of this technique, we applied it to the study of human primary T lymphocytes (T-cells). It allowed the fine monitoring of pushing and pulling forces generated by T-cells in response to various activating antibodies and bending stiffness of the micropipette. We further dissected the sequence of mechanical and morphological events occurring during T-cell activation to model force generation and to reveal heterogeneity in the cell population studied. We also report the first measurement of the changes in Young's modulus of T-cells during their activation, showing that T-cells stiffen within the first minutes of the activation process. © 2017 Sawicka et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  17. Motility, Force Generation, and Energy Consumption of Unicellular Parasites.

    Science.gov (United States)

    Hochstetter, Axel; Pfohl, Thomas

    2016-07-01

    Motility is a key factor for pathogenicity of unicellular parasites, enabling them to infiltrate and evade host cells, and perform several of their life-cycle events. State-of-the-art methods of motility analysis rely on a combination of optical tweezers with high-resolution microscopy and microfluidics. With this technology, propulsion forces, energies, and power generation can be determined so as to shed light on the motion mechanisms, chemotactic behavior, and specific survival strategies of unicellular parasites. With these new tools in hand, we can elucidate the mechanisms of motility and force generation of unicellular parasites, and identify ways to manipulate and eventually inhibit them. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. β-alanine supplementation improves isometric endurance of the knee extensor muscles

    Directory of Open Access Journals (Sweden)

    Sale Craig

    2012-06-01

    Full Text Available Abstract Background We examined the effect of four weeks of β-alanine supplementation on isometric endurance of the knee extensors at 45% maximal voluntary isometric contraction (MVIC. Methods Thirteen males (age 23 ± 6 y; height 1.80 ± 0.05 m; body mass 81.0 ± 10.5 kg, matched for pre-supplementation isometric endurance, were allocated to either a placebo (n = 6 or β-alanine (n = 7; 6.4 g·d-1 over 4 weeks supplementation group. Participants completed an isometric knee extension test (IKET to fatigue, at an intensity of 45% MVIC, before and after supplementation. In addition, two habituation tests were completed in the week prior to the pre-supplementation test and a further practice test was completed in the week prior to the post-supplementation test. MVIC force, IKET hold-time, and impulse generated were recorded. Results IKET hold-time increased by 9.7 ± 9.4 s (13.2% and impulse by 3.7 ± 1.3 kN·s-1 (13.9% following β-alanine supplementation. These changes were significantly greater than those in the placebo group (IKET: t(11 = 2.9, p ≤0.05; impulse: t(11 = 3.1, p ≤ 0.05. There were no significant changes in MVIC force in either group. Conclusion Four weeks of β-alanine supplementation at 6.4 g·d-1 improved endurance capacity of the knee extensors at 45% MVIC, which most likely results from improved pH regulation within the muscle cell as a result of elevated muscle carnosine levels.

  19. Ultrastructure of clots during isometric contraction

    OpenAIRE

    1982-01-01

    We explored the retraction or contraction of platelet-fibrin clots under isometric conditions. In the presence of micromolar calcium clots of normal platelet-rich plasma developed tension at an initial rate of 0.1 to 0.2 g/min per cm2 (initial cross-sectional area). Electron microscopy of clots fixed after attaining a force of 1.6 g/cm2 revealed platelets with elongated bodies and pseudopods in close apposition to fibrin strands which were oriented in cablelike fashion in the direction of ten...

  20. Forced circulation type steam generator simulation code: HT4

    International Nuclear Information System (INIS)

    Okamoto, Masaharu; Tadokoro, Yoshihiro

    1982-08-01

    The purpose of this code is a understanding of dynamic characteristics of the steam generator, which is a component of High-temperature Heat Transfer Components Test Unit. This unit is a number 4th test section of Helium Engineering Demonstration Loop (HENDEL). Features of this report are as follows, modeling of the steam generator, a basic relationship for the continuity equation, numerical analysis techniques of a non-linear simultaneous equation and computer graphics output techniques. Forced circulation type steam generator with strait tubes and horizontal cut baffles, applied in this code, have be designed at the Over All System Design of the VHTRex. The code is for use with JAERI's digital computer FACOM M200. About 1.5 sec required for each time step reiteration, then about 40 sec cpu time required for a standard problem. (author)

  1. Does dynamic stability govern propulsive force generation in human walking?

    Science.gov (United States)

    Browne, Michael G; Franz, Jason R

    2017-11-01

    Before succumbing to slower speeds, older adults may walk with a diminished push-off to prioritize stability over mobility. However, direct evidence for trade-offs between push-off intensity and balance control in human walking, independent of changes in speed, has remained elusive. As a critical first step, we conducted two experiments to investigate: (i) the independent effects of walking speed and propulsive force ( F P ) generation on dynamic stability in young adults, and (ii) the extent to which young adults prioritize dynamic stability in selecting their preferred combination of walking speed and F P generation. Subjects walked on a force-measuring treadmill across a range of speeds as well as at constant speeds while modulating their F P according to a visual biofeedback paradigm based on real-time force measurements. In contrast to improvements when walking slower, walking with a diminished push-off worsened dynamic stability by up to 32%. Rather, we find that young adults adopt an F P at their preferred walking speed that maximizes dynamic stability. One implication of these findings is that the onset of a diminished push-off in old age may independently contribute to poorer balance control and precipitate slower walking speeds.

  2. Probing cooperative force generation in collective cancer invasion

    Science.gov (United States)

    Alobaidi, Amani A.; Xu, Yaopengxiao; Chen, Shaohua; Jiao, Yang; Sun, Bo

    2017-08-01

    Collective cellular dynamics in the three-dimensional extracellular matrix (ECM) plays a crucial role in many physiological processes such as cancer invasion. Both chemical and mechanical signaling support cell-cell communications on a variety of length scales, leading to collective migratory behaviors. Here we conduct experiments using 3D in vitro tumor models and develop a phenomenological model in order to probe the cooperativity of force generation in the collective invasion of breast cancer cells. In our model, cell-cell communication is characterized by a single parameter that quantifies the correlation length of cellular migration cycles. We devise a stochastic reconstruction method to generate realizations of cell colonies with specific contraction phase correlation functions and correlation length a. We find that as a increases, the characteristic size of regions containing cells with similar contraction phases grows. For small a values, the large fluctuations in individual cell contraction phases smooth out the temporal fluctuations in the time-dependent deformation field in the ECM. For large a values, the periodicity of an individual cell contraction cycle is clearly manifested in the temporal variation of the overall deformation field in the ECM. Through quantitative comparisons of the simulated and experimentally measured deformation fields, we find that the correlation length for collective force generation in the breast cancer diskoid in geometrically micropatterned ECM (DIGME) system is a≈ 25~μ \\text{m} , which is roughly twice the linear size of a single cell. One possible mechanism for this intermediate cell correlation length is the fiber-mediated stress propagation in the 3D ECM network in the DIGME system.

  3. Influence of post-stroke spasticity on EMG-force coupling and force steadiness in biceps brachii.

    Science.gov (United States)

    Carlyle, Jennilee K; Mochizuki, George

    2018-02-01

    Individuals with spasticity after stroke experience a decrease in force steadiness which can impact function. Alterations in the strength of EMG-force coupling may contribute to the reduction in force steadiness observed in spasticity. The aim was to determine the extent to which force steadiness and EMG-force coupling is affected by post-stroke spasticity. This cross-sectional study involved individuals with upper limb spasticity after stroke. Participants were required to generate and maintain isometric contractions of the elbow flexors at varying force levels. Coefficient of variation of force, absolute force, EMG-force cross-correlation function peak and peak latency was measured from both limbs with surface electromyography and isometric dynamometry. Statistically significant differences were observed between the affected and less affected limbs for all outcome measures. Significant main effects of force level were also observed. Force steadiness was not statistically significantly correlated with EMG-force coupling; however, both force steadiness and absolute force were associated with the level of impairment as measured by the Chedoke McMaster Stroke Assessment Scale. Spasticity after stroke uncouples the relationship between EMG and force and is associated with reduced force steadiness during isometric contractions; however, these features of control are not associated in individuals with spasticity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Are there two forms of isometric muscle action? Results of the experimental study support a distinction between a holding and a pushing isometric muscle function.

    Science.gov (United States)

    Schaefer, Laura V; Bittmann, Frank N

    2017-01-01

    In isometric muscle function, there are subjectively two different modes of performance: one can either hold isometrically - thus resist an impacting force - or push isometrically - therefore work against a stable resistance. The purpose of this study is to investigate whether or not two different isometric muscle actions - the holding vs. pushing one (HIMA vs PIMA) - can be distinguished by objective parameters. Ten subjects performed two different measuring modes at 80% of MVC realized by a special pneumatic system. During HIMA the subject had to resist the defined impacting force of the pneumatic system in an isometric position, whereby the force of the cylinder works in direction of elbow flexion against the subject. During PIMA the subject worked isometrically in direction of elbow extension against a stable position of the system. The signals of pressure, force, acceleration and mechanomyography/-tendography (MMG/MTG) of the elbow extensor (MMGtri/MTGtri) and the abdominal muscle (MMGobl) were recorded and evaluated concerning the duration of maintaining the force level (force endurance) and the characteristics of MMG-/MTG-signals. Statistical group differences comparing HIMA vs. PIMA were estimated using SPSS. Significant differences between HIMA and PIMA were especially apparent regarding the force endurance: During HIMA the subjects showed a decisively shorter time of stable isometric position (19 ± 8 s) in comparison with PIMA (41 ± 24 s; p  = .005). In addition, during PIMA the longest isometric plateau amounted to 59.4% of the overall duration time of isometric measuring, during HIMA it lasted 31.6% ( p  = .000). The frequency of MMG/MTG did not show significant differences. The power in the frequency ranges of 8-15 Hz and 10-29 Hz was significantly higher in the MTGtri performing HIMA compared to PIMA (but not for the MMGs). The amplitude of MMG/MTG did not show any significant difference considering the whole measurement. However

  5. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  6. Generation of intermittent gravitocapillary waves via parametric forcing

    Science.gov (United States)

    Castillo, Gustavo; Falcón, Claudio

    2018-04-01

    We report on the generation of an intermittent wave field driven by a horizontally moving wave maker interacting with Faraday waves. The spectrum of the local gravitocapillary surface wave fluctuations displays a power law in frequency for a wide range of forcing parameters. We compute the probability density function of the local surface height increments, which show that they change strongly across time scales. The structure functions of these increments are shown to display power laws as a function of the time lag, with exponents that are nonlinear functions of the order of the structure function. We argue that the origin of this scale-invariant intermittent spectrum is the Faraday wave pattern breakup due to its advection by the propagating gravity waves. Finally, some interpretations are proposed to explain the appearance of this intermittent spectrum.

  7. Regulation of the basement membrane by epithelia generated forces

    Science.gov (United States)

    Tanner, Kandice

    2012-12-01

    Tumor metastasis involves a progressive loss of tissue architecture and dissolution of structural boundaries between the epithelium and connective tissue. The basement membrane (BM), a specialized network of extracellular matrix proteins forms a barrier that physically restricts pre-invasive lesions such that they remain as local insults. The BM is not a static structure, but one that is constantly regenerated and remodeled in the adult organism. Matrix organization also regulates cell function. Thus alterations in the balance of synthesis, remodeling and proteolytic degradation of the extracellular matrix proteins may contribute to a loss of structural integrity. However, the de novo assembly and maintenance of the complex structural properties of in vivo basement membranes remain elusive. Here, this paper highlights the current understanding on the structural properties and the establishment of the BM, and discusses the potential role of self-generated forces in adult tissue remodeling and the maintenance of the BM as a malignancy suppressor.

  8. Regulation of the basement membrane by epithelia generated forces

    International Nuclear Information System (INIS)

    Tanner, Kandice

    2012-01-01

    Tumor metastasis involves a progressive loss of tissue architecture and dissolution of structural boundaries between the epithelium and connective tissue. The basement membrane (BM), a specialized network of extracellular matrix proteins forms a barrier that physically restricts pre-invasive lesions such that they remain as local insults. The BM is not a static structure, but one that is constantly regenerated and remodeled in the adult organism. Matrix organization also regulates cell function. Thus alterations in the balance of synthesis, remodeling and proteolytic degradation of the extracellular matrix proteins may contribute to a loss of structural integrity. However, the de novo assembly and maintenance of the complex structural properties of in vivo basement membranes remain elusive. Here, this paper highlights the current understanding on the structural properties and the establishment of the BM, and discusses the potential role of self-generated forces in adult tissue remodeling and the maintenance of the BM as a malignancy suppressor. (paper)

  9. EEG signatures of arm isometric exertions in preparation, planning and execution.

    Science.gov (United States)

    Nasseroleslami, Bahman; Lakany, Heba; Conway, Bernard A

    2014-04-15

    The electroencephalographic (EEG) activity patterns in humans during motor behaviour provide insight into normal motor control processes and for diagnostic and rehabilitation applications. While the patterns preceding brisk voluntary movements, and especially movement execution, are well described, there are few EEG studies that address the cortical activation patterns seen in isometric exertions and their planning. In this paper, we report on time and time-frequency EEG signatures in experiments in normal subjects (n=8), using multichannel EEG during motor preparation, planning and execution of directional centre-out arm isometric exertions performed at the wrist in the horizontal plane, in response to instruction-delay visual cues. Our observations suggest that isometric force exertions are accompanied by transient and sustained event-related potentials (ERP) and event-related (de-)synchronisations (ERD/ERS), comparable to those of a movement task. Furthermore, the ERPs and ERD/ERS are also observed during preparation and planning of the isometric task. Comparison of ear-lobe-referenced and surface Laplacian ERPs indicates the contribution of superficial sources in supplementary and pre-motor (FC(z)), parietal (CP(z)) and primary motor cortical areas (C₁ and FC₁) to ERPs (primarily negative peaks in frontal and positive peaks in parietal areas), but contribution of deep sources to sustained time-domain potentials (negativity in planning and positivity in execution). Transient and sustained ERD patterns in μ and β frequency bands of ear-lobe-referenced and surface Laplacian EEG indicate the contribution of both superficial and deep sources to ERD/ERS. As no physical displacement happens during the task, we can infer that the underlying mechanisms of motor-related ERPs and ERD/ERS patterns do not only depend on change in limb coordinate or muscle-length-dependent ascending sensory information and are primary generated by motor preparation, direction

  10. Motor unit firing rate patterns during voluntary muscle force generation: a simulation study

    Science.gov (United States)

    Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.

    2014-04-01

    Objective. Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse ‘onion skin’ profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the ‘onion skin’ profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Approach. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. Main results. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse ‘onion skin’ pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the ‘onion skin’ pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the ‘onion skin’ paradigm than with the reverse ‘onion skin’ firing patterns, but this effect was reversed at high force levels. Significance. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.

  11. Field measurement of basal forces generated by erosive debris flows

    Science.gov (United States)

    McCoy, S.W.; Tucker, G.E.; Kean, J.W.; Coe, J.A.

    2013-01-01

    It has been proposed that debris flows cut bedrock valleys in steeplands worldwide, but field measurements needed to constrain mechanistic models of this process remain sparse due to the difficulty of instrumenting natural flows. Here we present and analyze measurements made using an automated sensor network, erosion bolts, and a 15.24 cm by 15.24 cm force plate installed in the bedrock channel floor of a steep catchment. These measurements allow us to quantify the distribution of basal forces from natural debris‒flow events that incised bedrock. Over the 4 year monitoring period, 11 debris‒flow events scoured the bedrock channel floor. No clear water flows were observed. Measurements of erosion bolts at the beginning and end of the study indicated that the bedrock channel floor was lowered by 36 to 64 mm. The basal force during these erosive debris‒flow events had a large‒magnitude (up to 21 kN, which was approximately 50 times larger than the concurrent time‒averaged mean force), high‒frequency (greater than 1 Hz) fluctuating component. We interpret these fluctuations as flow particles impacting the bed. The resulting variability in force magnitude increased linearly with the time‒averaged mean basal force. Probability density functions of basal normal forces were consistent with a generalized Pareto distribution, rather than the exponential distribution that is commonly found in experimental and simulated monodispersed granular flows and which has a lower probability of large forces. When the bed sediment thickness covering the force plate was greater than ~ 20 times the median bed sediment grain size, no significant fluctuations about the time‒averaged mean force were measured, indicating that a thin layer of sediment (~ 5 cm in the monitored cases) can effectively shield the subjacent bed from erosive impacts. Coarse‒grained granular surges and water‒rich, intersurge flow had very similar basal force distributions despite

  12. Length dependence of force generation exhibit similarities between rat cardiac myocytes and skeletal muscle fibres.

    Science.gov (United States)

    Hanft, Laurin M; McDonald, Kerry S

    2010-08-01

    According to the Frank-Starling relationship, increased ventricular volume increases cardiac output, which helps match cardiac output to peripheral circulatory demand. The cellular basis for this relationship is in large part the myofilament length-tension relationship. Length-tension relationships in maximally calcium activated preparations are relatively shallow and similar between cardiac myocytes and skeletal muscle fibres. During twitch activations length-tension relationships become steeper in both cardiac and skeletal muscle; however, it remains unclear whether length dependence of tension differs between striated muscle cell types during submaximal activations. The purpose of this study was to compare sarcomere length-tension relationships and the sarcomere length dependence of force development between rat skinned left ventricular cardiac myocytes and fast-twitch and slow-twitch skeletal muscle fibres. Muscle cell preparations were calcium activated to yield 50% maximal force, after which isometric force and rate constants (k(tr)) of force development were measured over a range of sarcomere lengths. Myofilament length-tension relationships were considerably steeper in fast-twitch fibres compared to slow-twitch fibres. Interestingly, cardiac myocyte preparations exhibited two populations of length-tension relationships, one steeper than fast-twitch fibres and the other similar to slow-twitch fibres. Moreover, myocytes with shallow length-tension relationships were converted to steeper length-tension relationships by protein kinase A (PKA)-induced myofilament phosphorylation. Sarcomere length-k(tr) relationships were distinct between all three cell types and exhibited patterns markedly different from Ca(2+) activation-dependent k(tr) relationships. Overall, these findings indicate cardiac myocytes exhibit varied length-tension relationships and sarcomere length appears a dominant modulator of force development rates. Importantly, cardiac myocyte length

  13. The role of the cytoskeleton in cellular force generation in 2D and 3D environments

    International Nuclear Information System (INIS)

    Kraning-Rush, Casey M; Carey, Shawn P; Califano, Joseph P; Smith, Brooke N; Reinhart-King, Cynthia A

    2011-01-01

    To adhere and migrate, cells generate forces through the cytoskeleton that are transmitted to the surrounding matrix. While cellular force generation has been studied on 2D substrates, less is known about cytoskeletal-mediated traction forces of cells embedded in more in vivo-like 3D matrices. Recent studies have revealed important differences between the cytoskeletal structure, adhesion, and migration of cells in 2D and 3D. Because the cytoskeleton mediates force, we sought to directly compare the role of the cytoskeleton in modulating cell force in 2D and 3D. MDA-MB-231 cells were treated with agents that perturbed actin, microtubules, or myosin, and analyzed for changes in cytoskeletal organization and force generation in both 2D and 3D. To quantify traction stresses in 2D, traction force microscopy was used; in 3D, force was assessed based on single cell-mediated collagen fibril reorganization imaged using confocal reflectance microscopy. Interestingly, even though previous studies have observed differences in cell behaviors like migration in 2D and 3D, our data indicate that forces generated on 2D substrates correlate with forces within 3D matrices. Disruption of actin, myosin or microtubules in either 2D or 3D microenvironments disrupts cell-generated force. These data suggest that despite differences in cytoskeletal organization in 2D and 3D, actin, microtubules and myosin contribute to contractility and matrix reorganization similarly in both microenvironments

  14. Isometric and swallowing tongue strength in healthy adults.

    Science.gov (United States)

    Todd, J Tee; Lintzenich, Catherine Rees; Butler, Susan G

    2013-10-01

    The tongue contributes to a safe swallow. It facilitates bolus control during mastication, maintains a bolus in the oral cavity to prevent premature entry of the bolus into the hypopharynx, and helps generate pressure in the hypopharynx during swallowing. This study examined isometric tongue strength and tongue pressure measured during swallowing in healthy young and older adults. Prospective group design. One hundred twenty-six healthy individuals who were recruited as part of a larger study on swallowing participated in this study. Participants were divided into three age groups: 20 to 40 years, 41 to 60 years, and ≥61 years. A KayPentax Digital Swallowing Workstation with an air-filled bulb array was placed on the tongue of each participant (anterior to posterior). Participants completed three isometric tongue presses and three swallows. Repeated measures analyses of variance revealed a significant main effect of age (P = .01) and gender by tongue bulb location interaction (P = .02) for isometric tongue strength. That is, older adults had lower isometric tongue strength than young adults, and females had a greater difference between anterior and posterior tongue strength than males. Tongue strength during swallowing yielded significantly greater anterior versus posterior tongue pressure. This study comprises one of the largest in terms of number of healthy participants reported to date and confirms previous findings that isometric tongue strength decreases with age. Furthermore, given young and older adults generate similar swallowing pressures, swallowing is a submaximal strength activity, yet older adults have less functional reserve. 4. Copyright © 2013 The American Laryngological, Rhinological, and Otological Society, Inc.

  15. Ground Reaction Forces Generated During Rhythmical Squats as a Dynamic Loads of the Structure

    Science.gov (United States)

    Pantak, Marek

    2017-10-01

    Dynamic forces generated by moving persons can lead to excessive vibration of the long span, slender and lightweight structure such as floors, stairs, stadium stands and footbridges. These dynamic forces are generated during walking, running, jumping and rhythmical body swaying in vertical or horizontal direction etc. In the paper the mathematical models of the Ground Reaction Forces (GRFs) generated during squats have been presented. Elaborated models was compared to the GRFs measured during laboratory tests carried out by author in wide range of frequency using force platform. Moreover, the GRFs models were evaluated during dynamic numerical analyses and dynamic field tests of the exemplary structure (steel footbridge).

  16. In-Vivo Measurement of Muscle Tension: Dynamic Properties of the MC Sensor during Isometric Muscle Contraction

    Directory of Open Access Journals (Sweden)

    Srđan Đorđević

    2014-09-01

    Full Text Available Skeletal muscle is the largest tissue structure in our body and plays an essential role for producing motion through integrated action with bones, tendons, ligaments and joints, for stabilizing body position, for generation of heat through cell respiration and for blood glucose disposal. A key function of skeletal muscle is force generation. Non-invasive and selective measurement of muscle contraction force in the field and in clinical settings has always been challenging. The aim of our work has been to develop a sensor that can overcome these difficulties and therefore enable measurement of muscle force during different contraction conditions. In this study, we tested the mechanical properties of a “Muscle Contraction” (MC sensor during isometric muscle contraction in different length/tension conditions. The MC sensor is attached so that it indents the skin overlying a muscle group and detects varying degrees of tension during muscular contraction. We compared MC sensor readings over the biceps brachii (BB muscle to dynamometric measurements of force of elbow flexion, together with recordings of surface EMG signal of BB during isometric contractions at 15° and 90° of elbow flexion. Statistical correlation between MC signal and force was very high at 15° (r = 0.976 and 90° (r = 0.966 across the complete time domain. Normalized SD or σN = σ/max(FMC was used as a measure of linearity of MC signal and elbow flexion force in dynamic conditions. The average was 8.24% for an elbow angle of 90° and 10.01% for an elbow of angle 15°, which indicates high linearity and good dynamic properties of MC sensor signal when compared to elbow flexion force. The next step of testing MC sensor potential will be to measure tension of muscle-tendon complex in conditions when length and tension change simultaneously during human motion.

  17. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Directory of Open Access Journals (Sweden)

    Bellar David

    2015-09-01

    Full Text Available The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4% volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain to a load cell (high frequency anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98 suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001 with all predictor variables attaining significance in the model (p<0.05. Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001. Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  18. Validation and Reliability of a Novel Test of Upper Body Isometric Strength.

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W

    2015-09-29

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (pIsometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  19. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W.

    2015-01-01

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203

  20. A standardized approach to study human variability in isometric thermogenesis during low-intensity physical activity

    Directory of Open Access Journals (Sweden)

    Delphine eSarafian

    2013-07-01

    Full Text Available Limitations of current methods: The assessment of human variability in various compartments of daily energy expenditure (EE under standardized conditions is well defined at rest (as basal metabolic rate and thermic effect of feeding, and currently under validation for assessing the energy cost of low-intensity dynamic work. However, because physical activities of daily life consist of a combination of both dynamic and isometric work, there is also a need to develop standardized tests for assessing human variability in the energy cost of low-intensity isometric work.Experimental objectives: Development of an approach to study human variability in isometric thermogenesis by incorporating a protocol of intermittent leg press exercise of varying low-intensity isometric loads with measurements of EE by indirect calorimetry. Results: EE was measured in the seated position with the subject at rest or while intermittently pressing both legs against a press-platform at 5 low-intensity isometric loads (+5, +10, + 15, +20 and +25 kg force, each consisting of a succession of 8 cycles of press (30 s and rest (30 s. EE, integrated over each 8-min period of the intermittent leg press exercise, was found to increase linearly across the 5 isometric loads with a correlation coefficient (r > 0.9 for each individual. The slope of this EE-Load relationship, which provides the energy cost of this standardized isometric exercise expressed per kg force applied intermittently (30 s in every min, was found to show good repeatability when assessed in subjects who repeated the same experimental protocol on 3 separate days: its low intra-individual coefficient of variation (CV of ~ 10% contrasted with its much higher inter-individual CV of 35%; the latter being mass-independent but partly explained by height. Conclusion: This standardized approach to study isometric thermogenesis opens up a new avenue for research in EE phenotyping and metabolic predisposition to obesity

  1. The use of the isometric squat as a measure of strength and explosiveness.

    Science.gov (United States)

    Bazyler, Caleb D; Beckham, George K; Sato, Kimitake

    2015-05-01

    The isometric squat has been used to detect changes in kinetic variables as a result of training; however, controversy exists in its application to dynamic multijoint tasks. Thus, the purpose of this study was to further examine the relationship between isometric squat kinetic variables and isoinertial strength measures. Subjects (17 men, 1-repetition maximum [1RM]: 148.2 ± 23.4 kg) performed squats 2 d · wk(-1) for 12 weeks and were tested on 1RM squat, 1RM partial squat, and isometric squat at 90° and 120° of knee flexion. Test-retest reliability was very good for all isometric measures (intraclass correlation coefficients > 0.90); however, rate of force development 250 milliseconds at 90° and 120° seemed to have a higher systematic error (relative technical error of measurement = 8.12%, 9.44%). Pearson product-moment correlations indicated strong relationships between isometric peak force at 90° (IPF 90°) and 1RM squat (r = 0.86), and IPF 120° and 1RM partial squat (r = 0.79). Impulse 250 milliseconds (IMP) at 90° and 120° exhibited moderate to strong correlations with 1RM squat (r = 0.70, 0.58) and partial squat (r = 0.73, 0.62), respectively. Rate of force development at 90° and 120° exhibited weak to moderate correlations with 1RM squat (r = 0.55, 0.43) and partial squat (r = 0.32, 0.42), respectively. These findings demonstrate a degree of joint angle specificity to dynamic tasks for rapid and peak isometric force production. In conclusion, an isometric squat performed at 90° and 120° is a reliable testing measure that can provide a strong indication of changes in strength and explosiveness during training.

  2. Dynamic Variability of Isometric Action Tremor in Precision Pinching

    Directory of Open Access Journals (Sweden)

    Tim Eakin

    2012-01-01

    Full Text Available Evolutionary development of isometric force impulse frequencies, power, and the directional concordance of changes in oscillatory tremor during performance of a two-digit force regulation task was examined. Analyses compared a patient group having tremor confounding volitional force regulation with a control group having no neuropathological diagnosis. Dependent variables for tremor varied temporally and spatially, both within individual trials and across trials, across individuals, across groups, and between digits. Particularly striking findings were magnitude increases during approaches to cue markers and shifts in the concordance phase from pinching toward rigid sway patterns as the magnitude increased. Magnitudes were significantly different among trace line segments of the task and were characterized by differences in relative force required and by the task progress with respect to cue markers for beginning, reversing force change direction, or task termination. The main systematic differences occurred during cue marker approach and were independent of trial sequence order.

  3. Electron tomography of cryofixed, isometrically contracting insect flight muscle reveals novel actin-myosin interactions.

    Directory of Open Access Journals (Sweden)

    Shenping Wu

    2010-09-01

    Full Text Available Isometric muscle contraction, where force is generated without muscle shortening, is a molecular traffic jam in which the number of actin-attached motors is maximized and all states of motor action are trapped with consequently high heterogeneity. This heterogeneity is a major limitation to deciphering myosin conformational changes in situ.We used multivariate data analysis to group repeat segments in electron tomograms of isometrically contracting insect flight muscle, mechanically monitored, rapidly frozen, freeze substituted, and thin sectioned. Improved resolution reveals the helical arrangement of F-actin subunits in the thin filament enabling an atomic model to be built into the thin filament density independent of the myosin. Actin-myosin attachments can now be assigned as weak or strong by their motor domain orientation relative to actin. Myosin attachments were quantified everywhere along the thin filament including troponin. Strong binding myosin attachments are found on only four F-actin subunits, the "target zone", situated exactly midway between successive troponin complexes. They show an axial lever arm range of 77°/12.9 nm. The lever arm azimuthal range of strong binding attachments has a highly skewed, 127° range compared with X-ray crystallographic structures. Two types of weak actin attachments are described. One type, found exclusively in the target zone, appears to represent pre-working-stroke intermediates. The other, which contacts tropomyosin rather than actin, is positioned M-ward of the target zone, i.e. the position toward which thin filaments slide during shortening.We present a model for the weak to strong transition in the myosin ATPase cycle that incorporates azimuthal movements of the motor domain on actin. Stress/strain in the S2 domain may explain azimuthal lever arm changes in the strong binding attachments. The results support previous conclusions that the weak attachments preceding force generation are very

  4. Electron Tomography of Cryofixed, Isometrically Contracting Insect Flight Muscle Reveals Novel Actin-Myosin Interactions

    International Nuclear Information System (INIS)

    Wu, Shenping; Liu, Jun; Reedy, Mary C.; Tregear, Richard T.; Winkler, Hanspeter; Franzini-Armstrong, Clara; Sasaki, Hiroyuki; Lucaveche, Carmen; Goldman, Yale E.; Reedy, Michael K.; Taylor, Kenneth A.

    2010-01-01

    Isometric muscle contraction, where force is generated without muscle shortening, is a molecular traffic jam in which the number of actin-attached motors is maximized and all states of motor action are trapped with consequently high heterogeneity. This heterogeneity is a major limitation to deciphering myosin conformational changes in situ. We used multivariate data analysis to group repeat segments in electron tomograms of isometrically contracting insect flight muscle, mechanically monitored, rapidly frozen, freeze substituted, and thin sectioned. Improved resolution reveals the helical arrangement of F-actin subunits in the thin filament enabling an atomic model to be built into the thin filament density independent of the myosin. Actin-myosin attachments can now be assigned as weak or strong by their motor domain orientation relative to actin. Myosin attachments were quantified everywhere along the thin filament including troponin. Strong binding myosin attachments are found on only four F-actin subunits, the 'target zone', situated exactly midway between successive troponin complexes. They show an axial lever arm range of 77 o /12.9 nm. The lever arm azimuthal range of strong binding attachments has a highly skewed, 127 o range compared with X-ray crystallographic structures. Two types of weak actin attachments are described. One type, found exclusively in the target zone, appears to represent pre-working-stroke intermediates. The other, which contacts tropomyosin rather than actin, is positioned M-ward of the target zone, i.e. the position toward which thin filaments slide during shortening. We present a model for the weak to strong transition in the myosin ATPase cycle that incorporates azimuthal movements of the motor domain on actin. Stress/strain in the S2 domain may explain azimuthal lever arm changes in the strong binding attachments. The results support previous conclusions that the weak attachments preceding force generation are very different from

  5. Surface texture generation during cylindrical milling in the aspect of cutting force variations

    International Nuclear Information System (INIS)

    Wojciechowski, S; Twardowski, P; Pelic, M

    2014-01-01

    The work presented here concentrates on surface texture analysis, after cylindrical milling of hardened steel. Cutting force variations occurring in the machining process have direct influence on the cutter displacements and thus on the generated surface texture. Therefore, in these experiments, the influence of active number of teeth (z c ) on the cutting force variations was investigated. Cutting forces and cutter displacements were measured during machining process (online) using, namely piezoelectric force dynamometer and 3D laser vibrometer. Surface roughness parameters were measured using stylus surface profiler. The surface roughness model including cutting parameters (f z , D) and cutting force variations was also developed. The research revealed that in cylindrical milling process, cutting force variations have immediate influence on surface texture generation

  6. Level of hamstrings damage depending on force-generating capacity and creatine kinase activity

    OpenAIRE

    Carmona, Gerard; Alomar, Xavier; Mendiguchia, Jurdan; Serrano, David; Padullés, Josep Maria; Nescolarde Selva, Lexa Digna; Rodas Font, Gil; Cusso Calabuig, Roser; Guerrero, M.; Idoate, F.; Balius, Ramon; Cadefau, Joan

    2014-01-01

    The aim of the present study was to categorize the eccentric exercise-induced hamstrings damage by using easy measurable markers such as force-generating capacity and serum creatine kinase activity Peer Reviewed

  7. Electromagnetic force analysis on the stator and rotor windings of a superconducting generator

    International Nuclear Information System (INIS)

    Colovini, L.; Martinelli, G.; Morini, A.

    1985-01-01

    The determination of values and distribution of the forces acting on the components of a superconducting generator is important when designing the machine, particularly in the choice of materials. The paper analyses the electromagnetic forces acting on the field and armature windings; for this purpose, with reference to the preliminary design of a two-pole 300 MVA superconducting generator, a two-dimensional analytical method set up by the authors is utilized to calculate the forces on the windings under steady state operation and results are compared with those obtained by means of a numerical method

  8. Isometric parameters in the monitoring of maximal strength, power, and hypertrophic resistance-training.

    Science.gov (United States)

    Peltonen, Heikki; Walker, Simon; Lähitie, Anuliisa; Häkkinen, Keijo; Avela, Janne

    2018-02-01

    This study monitored strength-training adaptations via isometric parameters throughout 2 × 10 weeks of hypertrophic (HYP I-II) or 10 weeks maximum strength (MS) followed by 10 weeks power (P) training with untrained controls. Trainees performed bilateral isometric leg press tests analyzed for peak force (maximal voluntary contraction (MVC)) and rate of force development (RFD) every 3.5 weeks. These parameters were compared with dynamic performance, voluntary and electrically induced isometric contractions, muscle activity, and cross-sectional area (CSA) in the laboratory before and after 10 and 20 weeks. RFD increased similarly during the first 7 weeks (HYP I, 44% ± 53%; MS, 48% ± 55%, P strength/power training, while MVC cannot distinguish between strength or muscle mass changes. Monitoring RFD provided important information regarding plateaus in RFD improvement, which were observed in dynamic explosive performances after HYP II compared with P.

  9. Neural control of muscle force: indications from a simulation model

    Science.gov (United States)

    Luca, Carlo J. De

    2013-01-01

    We developed a model to investigate the influence of the muscle force twitch on the simulated firing behavior of motoneurons and muscle force production during voluntary isometric contractions. The input consists of an excitatory signal common to all the motor units in the pool of a muscle, consistent with the “common drive” property. Motor units respond with a hierarchically structured firing behavior wherein at any time and force, firing rates are inversely proportional to recruitment threshold, as described by the “onion skin” property. Time- and force-dependent changes in muscle force production are introduced by varying the motor unit force twitches as a function of time or by varying the number of active motor units. A force feedback adjusts the input excitation, maintaining the simulated force at a target level. The simulations replicate motor unit behavior characteristics similar to those reported in previous empirical studies of sustained contractions: 1) the initial decrease and subsequent increase of firing rates, 2) the derecruitment and recruitment of motor units throughout sustained contractions, and 3) the continual increase in the force fluctuation caused by the progressive recruitment of larger motor units. The model cautions the use of motor unit behavior at recruitment and derecruitment without consideration of changes in the muscle force generation capacity. It describes an alternative mechanism for the reserve capacity of motor units to generate extraordinary force. It supports the hypothesis that the control of motoneurons remains invariant during force-varying and sustained isometric contractions. PMID:23236008

  10. Age-associated changes in muscle activity during isometric contraction.

    Science.gov (United States)

    Arjunan, Sridhar P; Kumar, Dinesh K

    2013-04-01

    We investigated the effect of age on the complexity of muscle activity and the variance in the force of isometric contraction. Surface electromyography (sEMG) from biceps brachii muscle and force of contraction were recorded from 96 subjects (20-70 years of age) during isometric contractions. There was a reduction in the complexity of sEMG associated with aging. The relationship of age and complexity was approximated using a bilinear fit, with the average knee point at 45 years. There was an age-associated increase in the coefficient of variation (CoV) of the force of muscle contraction, and this increase was correlated with the decrease in complexity of sEMG (r(2) = 0.76). There was an age-associated increase in CoV and also a reduction in the complexity of sEMG. The correlation between these 2 factors can be explained based on the age-associated increase in motor unit density. Copyright © 2012 Wiley Periodicals, Inc.

  11. Fatigue and muscle-tendon stiffness after stretch-shortening cycle and isometric exercise.

    Science.gov (United States)

    Toumi, Hechmi; Poumarat, Georges; Best, Thomas M; Martin, Alain; Fairclough, John; Benjamin, Mike

    2006-10-01

    The purpose of the present study was to compare vertical jump performance after 2 different fatigue protocols. In the first protocol, subjects performed consecutive sets of 10 repetitions of stretch-shortening cycle (SSC) contractions. In the second protocol, successive sets of 10 repetitions of isometric contractions were performed for 10 s with the knee at 90 degrees of flexion. The exercises were stopped when the subjects failed to reach 50% of their maximum voluntary isometric contractions. Maximal isometric force and maximal concentric power were assessed by performing supine leg presses, squat jumps, and drop jumps. Surface EMG was used to determine changes in muscle activation before and after fatigue. In both groups, the fatigue exercises reduced voluntary isometric force, maximal concentric power, and drop jump performance. Kinematic data showed a decrease in knee muscle-tendon stiffness accompanied by a lengthened ground contact time. EMG analysis showed that the squat and drop jumps were performed similarly before and after the fatigue exercise for both groups. Although it was expected that the stiffness would decrease more after SSC than after isometric fatigue (as a result of a greater alteration of the reflex sensitivity SSC), our results showed that both protocols had a similar effect on knee muscle stiffness during jumping exercises. Both fatigue protocols induced muscle fatigue, and the decrease in jump performance was linked to a decrease in the strength and stiffness of the knee extensor muscles.

  12. Cervical Muscle Strength and Muscle Coactivation During Isometric Contractions in Patients With Migraine: A Cross-Sectional Study.

    Science.gov (United States)

    Florencio, Lidiane Lima; de Oliveira, Anamaria Siriani; Carvalho, Gabriela Ferreira; Tolentino, Gabriella de Almeida; Dach, Fabiola; Bigal, Marcelo Eduardo; Fernández-de-las-Peñas, César; Bevilaqua Grossi, Débora

    2015-01-01

    This cross-sectional study investigated potential differences in cervical musculature in groups of migraine headaches vs. non-headache controls. Differences in cervical muscle strength and antagonist coactivation during maximal isometric voluntary contraction (MIVC) were analyzed between individuals with migraine and non-headache subjects and relationships between force with migraine and neck pain clinical aspects. A customized hand-held dynamometer was used to assess cervical flexion, extension, and bilateral lateral flexion strength in subjects with episodic migraine (n=31), chronic migraine (n = 21) and healthy controls (n = 31). Surface electromyography (EMG) from sternocleidomastoid, anterior scalene, and splenius capitis muscles were recorded during MIVC to evaluate antagonist coactivation. Comparison of main outcomes among groups was conducted with one-way analysis of covariance with the presence of neck pain as covariable. Correlations between peak force and clinical variables were demonstrated by Spearman's coefficient. Chronic migraine subjects exhibited lower cervical extension force (mean diff. from controls: 4.4 N/kg; mean diff from episodic migraine: 3.7 N/kg; P = .006) and spent significantly more time to generate peak force during cervical flexion (mean diff. from controls: 0.5 seconds; P = .025) and left lateral-flexion (mean diff. from controls: 0.4 seconds; mean diff. from episodic migraine: 0.5 seconds; P = .007). Both migraine groups showed significantly higher antagonist muscle coactivity of the splenius capitis muscle (mean diff. from controls: 20%MIVC, P = .03) during cervical flexion relative to healthy controls. Cervical extension peak force was moderately associated with the migraine frequency (rs: -0.30, P = .034), neck pain frequency (rs: -0.26, P = .020), and neck pain intensity (rs: -0.27, P = .012). Patients with chronic migraine exhibit altered muscle performance, took longer to reach peak of

  13. Characterization of sliders for efficient force generation of electrostatically controlled linear actuator

    International Nuclear Information System (INIS)

    Nguyen, T A; Konishi, S

    2014-01-01

    In this paper, the characterization of sliders for efficient force generation of an electrostatically controlled linear actuator (ECLIA) is investigated. The ECLIA consists of a piezoactuator (PZT), driving and holding electrodes, multiple sliders and a guide structure. The stepping motion of the sliders is driven by the PZT actuator via an electrostatic clutch mechanism. Thus, multiple sliders can achieve parallel, independent, precise motion, and a large stroke. Previous studies have indicated that the Si bulk slider and Si electrode created an air gap owing to the deformation of the Si electrode. Thus, the Si slider generated a low pushing force. In this study, we propose a fishbone structure mounted on a flexible slider to enhance the pushing force of the slider. The flexible slider, that can deform and fit into the Si electrode to reduce the air gap, results in highly efficient electrostatic-force generation. The fishbone structure improves the longitudinal stiffness of the flexible slider for high pushing-force generation. The results show that the pushing force created by the fishbone slider was three times greater than that of the conventional Si slider. The fishbone and flexible sliders exhibited a high performance for the ECLIA. (paper)

  14. Combined isometric and vibration training does not enhance strength beyond that of isometric training alone.

    Science.gov (United States)

    Fisher, J; Van-Dongen, M; Sutherland, R

    2015-09-01

    Research considering combined vibration and strength training is extensive yet results are equivocal. However, to date there appears no research which has considered the combination of both direct vibration and whole-body vibration when used in an isometric deadlift position. The aim of this study was to compare groups performing isometric training with and without direct and whole-body vibration. Twenty four participants (19-24 years) were randomly divided into: isometric training with vibration (ST+VT: N.=8), isometric training without vibration (ST: N.=8), and control (CON: N.=8). Within the training groups participants trained twice per week, for 6 weeks, performing 6-sets of maximal isometric deadlift contractions, increasing in duration from 30 seconds to 40 seconds (weeks 1-6). Hip and knee angle was maintained at 60° and 110°, respectively for both testing and training. Training sessions for ST+VT were identical to ST with the addition of a direct vibratory stimulus through hand-held straps and whole-body vibration via standing on vibration a platform. The amplitude remained constant (2 mm) throughout the intervention whilst the frequency increased from 35Hz to 50Hz. Pre- and post-test isometric strength was measured using an isometric deadlift dynamometer. Results revealed significant increases in isometric strength for both ST+VT (Pstrength training.

  15. Task complexity and maximal isometric strength gains through motor learning

    Science.gov (United States)

    McGuire, Jessica; Green, Lara A.; Gabriel, David A.

    2014-01-01

    Abstract This study compared the effects of a simple versus complex contraction pattern on the acquisition, retention, and transfer of maximal isometric strength gains and reductions in force variability. A control group (N = 12) performed simple isometric contractions of the wrist flexors. An experimental group (N = 12) performed complex proprioceptive neuromuscular facilitation (PNF) contractions consisting of maximal isometric wrist extension immediately reversing force direction to wrist flexion within a single trial. Ten contractions were completed on three consecutive days with a retention and transfer test 2‐weeks later. For the retention test, the groups performed their assigned contraction pattern followed by a transfer test that consisted of the other contraction pattern for a cross‐over design. Both groups exhibited comparable increases in strength (20.2%, P < 0.01) and reductions in mean torque variability (26.2%, P < 0.01), which were retained and transferred. There was a decrease in the coactivation ratio (antagonist/agonist muscle activity) for both groups, which was retained and transferred (35.2%, P < 0.01). The experimental group exhibited a linear decrease in variability of the torque‐ and sEMG‐time curves, indicating transfer to the simple contraction pattern (P < 0.01). The control group underwent a decrease in variability of the torque‐ and sEMG‐time curves from the first day of training to retention, but participants returned to baseline levels during the transfer condition (P < 0.01). However, the difference between torque RMS error versus the variability in torque‐ and sEMG‐time curves suggests the demands of the complex task were transferred, but could not be achieved in a reproducible way. PMID:25428951

  16. Effects of Isometric Scaling on Vertical Jumping Performance

    Science.gov (United States)

    Bobbert, Maarten F.

    2013-01-01

    Jump height, defined as vertical displacement in the airborne phase, depends on vertical takeoff velocity. For centuries, researchers have speculated on how jump height is affected by body size and many have adhered to what has come to be known as Borelli’s law, which states that jump height does not depend on body size per se. The underlying assumption is that the amount of work produced per kg body mass during the push-off is independent of size. However, if a big body is isometrically downscaled to a small body, the latter requires higher joint angular velocities to achieve a given takeoff velocity and work production will be more impaired by the force-velocity relationship of muscle. In the present study, the effects of pure isometric scaling on vertical jumping performance were investigated using a biologically realistic model of the human musculoskeletal system. The input of the model, muscle stimulation over time, was optimized using jump height as criterion. It was found that when the human model was miniaturized to the size of a mouse lemur, with a mass of about one-thousandth that of a human, jump height dropped from 40 cm to only 6 cm, mainly because of the force-velocity relationship. In reality, mouse lemurs achieve jump heights of about 33 cm. By implication, the unfavourable effects of the small body size of mouse lemurs on jumping performance must be counteracted by favourable effects of morphological and physiological adaptations. The same holds true for other small jumping animals. The simulations for the first time expose and explain the sheer magnitude of the isolated effects of isometric downscaling on jumping performance, to be counteracted by morphological and physiological adaptations. PMID:23936494

  17. Effects of isometric scaling on vertical jumping performance.

    Directory of Open Access Journals (Sweden)

    Maarten F Bobbert

    Full Text Available Jump height, defined as vertical displacement in the airborne phase, depends on vertical takeoff velocity. For centuries, researchers have speculated on how jump height is affected by body size and many have adhered to what has come to be known as Borelli's law, which states that jump height does not depend on body size per se. The underlying assumption is that the amount of work produced per kg body mass during the push-off is independent of size. However, if a big body is isometrically downscaled to a small body, the latter requires higher joint angular velocities to achieve a given takeoff velocity and work production will be more impaired by the force-velocity relationship of muscle. In the present study, the effects of pure isometric scaling on vertical jumping performance were investigated using a biologically realistic model of the human musculoskeletal system. The input of the model, muscle stimulation over time, was optimized using jump height as criterion. It was found that when the human model was miniaturized to the size of a mouse lemur, with a mass of about one-thousandth that of a human, jump height dropped from 40 cm to only 6 cm, mainly because of the force-velocity relationship. In reality, mouse lemurs achieve jump heights of about 33 cm. By implication, the unfavourable effects of the small body size of mouse lemurs on jumping performance must be counteracted by favourable effects of morphological and physiological adaptations. The same holds true for other small jumping animals. The simulations for the first time expose and explain the sheer magnitude of the isolated effects of isometric downscaling on jumping performance, to be counteracted by morphological and physiological adaptations.

  18. Shortening actin filaments cause force generation in actomyosin network to change from contractile to extensile

    Science.gov (United States)

    Kumar, Nitin; Gardel, Margaret

    Motor proteins in conjunction with filamentous proteins convert biochemical energy into mechanical energy which serves a number of cellular processes including cell motility, force generation and intracellular cargo transport. In-vitro experiments suggest that the forces generated by kinesin motors on microtubule bundles are extensile in nature whereas myosin motors on actin filaments are contractile. It is not clear how qualitatively similar systems can show completely different behaviors in terms of the nature of force generation. In order to answer this question, we carry out in vitro experiments where we form quasi 2D filamentous actomyosin networks and vary the length of actin filaments by adding capping protein. We show that when filaments are much shorter than their typical persistence length (approximately 10 microns), the forces generated are extensile and we see active nematic defect propagation, as seen in the microtubule-kinesin system. Based on this observation, we claim that the rigidity of rods plays an important role in dictating the nature of force generation in such systems. In order to understand this transition, we selectively label individual filaments and find that longer filaments show considerable bending and buckling, making them difficult to slide and extend along their length.

  19. Relationship Between Erectores Spinae Voltage and Back-Lift Strength for Isometric, Concentric, and Eccentric Contractions

    Science.gov (United States)

    Ashton, T. Edwin J.; Singh, Mohan

    1975-01-01

    This study determined the maximal mean values for concentric and eccentric back-lift strength as well as isometric, and examined and compared the relationships between the mean peak voltage of the erectores spinae muscle(s) and maximal force exerted for the three types of muscle contractions. (RC)

  20. Design of a new torque standard machine based on a torque generation method using electromagnetic force

    International Nuclear Information System (INIS)

    Nishino, Atsuhiro; Ueda, Kazunaga; Fujii, Kenichi

    2017-01-01

    To allow the application of torque standards in various industries, we have been developing torque standard machines based on a lever deadweight system, i.e. a torque generation method using gravity. However, this method is not suitable for expanding the low end of the torque range, because of the limitations to the sizes of the weights and moment arms. In this study, the working principle of the torque generation method using an electromagnetic force was investigated by referring to watt balance experiments used for the redefinition of the kilogram. Applying this principle to a rotating coordinate system, an electromagnetic force type torque standard machine was designed and prototyped. It was experimentally demonstrated that SI-traceable torque could be generated by converting electrical power to mechanical power. Thus, for the first time, SI-traceable torque was successfully realized using a method other than that based on the force of gravity. (paper)

  1. Evaluation of the attractive force of different types of new-generation magnetic attachment systems.

    Science.gov (United States)

    Akin, Hakan; Coskun, M Emre; Akin, E Gulsah; Ozdemir, A Kemal

    2011-03-01

    Rare earth magnets have been used in prosthodontics, but their tendency for corrosion in the oral cavity and insufficient attractive forces limit long-term clinical application. The purpose of this study was to evaluate the attractive force of different types of new-generation magnetic attachment systems. The attractive force of the neodymium-iron-boron (Nd-Fe-B) and samarium-cobalt (Sm-Co) magnetic attachment systems, including closed-field (Hilop and Hicorex) and open-field (Dyna and Steco) systems, was measured in a universal testing machine (n=5). The data were statistically evaluated with 1-way ANOVA and post hoc Tukey-Kramer multiple comparison test (α=.05). The closed-field systems exhibited greater (Pattractive force than the open-field systems. Moreover, there was a statistically significant difference in attractive force between Nd-Fe-B and Sm-Co magnets (Pattractive force was found with the Hilop system (9.2 N), and the lowest force was found with the Steco system (2.3 N). The new generation of Nd-Fe-B closed-field magnets, along with improved technology, provides sufficient denture retention for clinical application. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  2. Nonlinear effects in the radiation force generated by amplitude-modulated focused beams

    Science.gov (United States)

    González, Nuria; Jiménez, Noé; Redondo, Javier; Roig, Bernardino; Picó, Rubén; Sánchez-Morcillo, Víctor; Konofagou, Elisa E.; Camarena, Francisco

    2012-10-01

    Harmonic Motion Imaging (HMI) uses an amplitude-modulated (AM) beam to induce an oscillatory radiation force before, during and after ablation. In this paper, the findings from a numerical analysis of the effects related with the nonlinear propagation of AM focused ultrasonic beams in water on the radiation force and the location of its maxima will be presented. The numerical modeling is performed using the KZK nonlinear parabolic equation. The radiation force is generated by a focused transducer with a gain of 18, a carrier frequency of 1 MHz and a modulation frequency of 25 kHz. The modulated excitation generates a spatially-invariant force proportional to the intensity. Regarding the nonlinear wave propagation, the force is no longer proportional to the intensity, reaching a factor of eight between the nonlinear and linear estimations. Also, a 9 mm shift in the on-axis force peak occurs when the initial pressure increased from 1 to 300 kPa. This spatial shift, due to the nonlinear effects, becomes dynamic in AM focused beams, as the different signal periods have different amplitudes. This study shows that both the value and the spatial position of the force peak are affected by the nonlinear propagation of the ultrasonic waves.

  3. Effectiveness of various isometric exercises at improving bone strength in cortical regions prone to distal tibial stress fractures.

    Science.gov (United States)

    Florio, C S

    2018-06-01

    A computational model was used to compare the local bone strengthening effectiveness of various isometric exercises that may reduce the likelihood of distal tibial stress fractures. The developed model predicts local endosteal and periosteal cortical accretion and resorption based on relative local and global measures of the tibial stress state and its surface variation. Using a multisegment 3-dimensional leg model, tibia shape adaptations due to 33 combinations of hip, knee, and ankle joint angles and the direction of a single or sequential series of generated isometric resultant forces were predicted. The maximum stress at a common fracture-prone region in each optimized geometry was compared under likely stress fracture-inducing midstance jogging conditions. No direct correlations were found between stress reductions over an initially uniform circular hollow cylindrical geometry under these critical design conditions and the exercise-based sets of active muscles, joint angles, or individual muscle force and local stress magnitudes. Additionally, typically favorable increases in cross-sectional geometric measures did not guarantee stress decreases at these locations. Instead, tibial stress distributions under the exercise conditions best predicted strengthening ability. Exercises producing larger anterior distal stresses created optimized tibia shapes that better resisted the high midstance jogging bending stresses. Bent leg configurations generating anteriorly directed or inferiorly directed resultant forces created favorable adaptations. None of the studied loads produced by a straight leg was significantly advantageous. These predictions and the insight gained can provide preliminary guidance in the screening and development of targeted bone strengthening techniques for those susceptible to distal tibial stress fractures. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Isometric arm strength and subjective rating of upper limb fatigue in two-handed carrying tasks.

    Science.gov (United States)

    Li, Kai Way; Chiu, Wen-Sheng

    2015-01-01

    Sustained carrying could result in muscular fatigue of the upper limb. Ten male and ten female subjects were recruited for measurements of isometric arm strength before and during carrying a load for a period of 4 minutes. Two levels of load of carrying were tested for each of the male and female subjects. Exponential function based predictive equations for the isometric arm strength were established. The mean absolute deviations of these models in predicting the isometric arm strength were in the range of 3.24 to 17.34 N. Regression analyses between the subjective ratings of upper limb fatigue and force change index (FCI) for the carrying were also performed. The results indicated that the subjective rating of muscular fatigue may be estimated by multiplying the FCI with a constant. The FCI may, therefore, be adopted as an index to assess muscular fatigue for two-handed carrying tasks.

  5. Effects of plyometric and isometric training on muscle and tendon stiffness in vivo.

    Science.gov (United States)

    Kubo, Keitaro; Ishigaki, Tomonobu; Ikebukuro, Toshihiro

    2017-08-01

    The purpose of this study was to compare the effects of plyometric and isometric training on tendon properties during ramp and ballistic contractions and muscle stiffness under passive and active conditions. Eleven subjects completed 12 weeks (3 days/week) of a unilateral training program for the plantar flexors. They performed plyometric training on one side (PLY) and isometric training on the other side (ISO). Active muscle stiffness in the medial gastrocnemius muscle was calculated according to changes in estimated muscle force and fascicle length during fast stretching after submaximal isometric contractions. Passive muscle stiffness was also calculated from estimated passive muscle force and fascicle length during slow passive stretching. Stiffness and hysteresis of tendon structures were measured using ultrasonography during ramp and ballistic contractions. Passive muscle stiffness and tendon hysteresis did not change for PLY or ISO Active muscle stiffness significantly increased for PLY, but not for ISO Tendon stiffness during ramp and ballistic contractions increased significantly for ISO, but not for PLY In addition, tendon elongation values at force production levels beyond 100 N during ballistic contractions increased for PLY These results suggest that plyometric training (but not isometric training) enhances the extensibility of tendon structures during ballistic contractions and active muscle stiffness during fast stretching, and these changes may be related to improved performances during stretch-shortening cycle exercises. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  6. Low-Back Biomechanics and Static Stability During Isometric Pushing

    Science.gov (United States)

    Granata, Kevin P.; Bennett, Bradford C.

    2006-01-01

    Pushing and pulling tasks are increasingly prevalent in industrial workplaces. Few studies have investigated low-back biomechanical risk factors associated with pushing, and we are aware of none that has quantified spinal stability during pushing exertions. Data recorded from 11 healthy participants performing isometric pushing exertions demonstrated that trunk posture, vector force direction of the applied load, and trunk moment were influenced (p pushing task, and foot position. A biomechanical model was used to analyze the posture and hand force data gathered from the pushing exertions. Model results indicate that pushing exertions provide significantly (p pushing exertions. If one maintains stability by means of cocontraction, additional spinal load is thereby created, increasing the risk of overload injury. Thus it is important to consider muscle cocontraction when evaluating the biomechanics of pushing exertions. Potential applications of this research include improved assessment of biomechanical risk factors for the design of industrial pushing tasks. PMID:16435695

  7. Guidelines for random excitation forces due to cross flow in steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, C.E.; Pettigrew, M.J. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1998-07-01

    Random excitation forces can cause low-amplitude tube motion that will result in long-term fretting-wear or fatigue. To prevent these tube failures in steam generators and other heat exchangers, designers and trouble-shooters must have guidelines that incorporate random or turbulent fluid forces. Experiments designed to measure fluid forces have been carried out at Chalk River Laboratories and at other labs around the world. The data from these experiments have been studied and collated to determine suitable guidelines for random excitation forces. In this paper, a guideline for random excitation forces in single-phase cross flow is presented in the form of normalised spectra that are applicable to a wide range of flow conditions and tube frequencies. In particular, the experimental results used in this study were carried out over the full range of flow conditions found in a nuclear steam generator. The proposed guidelines are applicable to steam generators, condensers, reheaters and other shell-and-tube heat exchangers. They may be used for flow-induced vibration analysis of new or existing components, as input to vibration analysis computer codes and as specifications in procurement documents. (author)

  8. Guidelines for random excitation forces due to cross flow in steam generators

    International Nuclear Information System (INIS)

    Taylor, C.E.; Pettigrew, M.J.

    1998-01-01

    Random excitation forces can cause low-amplitude tube motion that will result in long-term fretting-wear or fatigue. To prevent these tube failures in steam generators and other heat exchangers, designers and trouble-shooters must have guidelines that incorporate random or turbulent fluid forces. Experiments designed to measure fluid forces have been carried out at Chalk River Laboratories and at other labs around the world. The data from these experiments have been studied and collated to determine suitable guidelines for random excitation forces. In this paper, a guideline for random excitation forces in single-phase cross flow is presented in the form of normalised spectra that are applicable to a wide range of flow conditions and tube frequencies. In particular, the experimental results used in this study were carried out over the full range of flow conditions found in a nuclear steam generator. The proposed guidelines are applicable to steam generators, condensers, reheaters and other shell-and-tube heat exchangers. They may be used for flow-induced vibration analysis of new or existing components, as input to vibration analysis computer codes and as specifications in procurement documents. (author)

  9. Cogging force investigation of a free piston permanent magnet linear generator

    Science.gov (United States)

    Abdalla, I. I.; Zainal, A. E. Z.; Ramlan, N. A.; Firmansyah; Aziz, A. R. A.; Heikal, M. R.

    2017-10-01

    Better performance and higher efficiency of the vehicles can be achieved by using free piston engine, in which the piston is connected directly to the linear generator and waiving of any mechanical means. The free piston engine has the ability to overcome or reduce many of the challenges, such as the carbon dioxide (CO2) emission and fossil fuel consumption. The cogging force produces undesired vibration and acoustic noise in the generator. However, the cogging force must be minimized as much as possible, in order to have a high performance. This paper studies the effects of ferromagnetic materials on the cogging force of the permanent magnet linear generator (PMLG) to be used in a free piston engine using nonlinear finite-element analysis (FEA) under ANSYS Maxwell. The comparisons have been established for the cogging force of the PMLG under various translator velocities and three different ferromagnetic materials for the stator core, namely, Silicon Steel laminations, Mild Steel and Somaloy. It has been shown that the PMLG with a stator core made of Somaloy has a lower cogging force among them. Furthermore, the induced voltage of the PMLG at different accelerations has been studied. It is found that the PMLG with Mild Steel and Somaloy, respectively give larger induced voltage. Moreover, as the translator speed increase the induced voltage increased.

  10. Glenohumeral range of motion (ROM) and isometric strength of professional team handball athletes, part III: changes over the playing season.

    Science.gov (United States)

    Fieseler, Georg; Jungermann, Philipp; Koke, Alexander; Irlenbusch, Lars; Delank, Karl-Stefan; Schwesig, René

    2015-12-01

    The aim of our study was to investigate the relation of workload on range of motion and isometric strength of team handball athletes' shoulders over a competitive season. 31 Professional male handball athletes underwent clinical shoulder examinations. Athletes were examined subsequently during the complete playing season (week 0, 6, 22 and 40) to determine bilateral isometric shoulder rotational strength and active range of motion (ROM). In addition, relative (intraclass correlation coefficients (ICC) and absolute (standard error of measurement) reliability were calculated. Intraobserver reliability was excellent (ICC 0.76-0.98) for isometric strength and flexibility measurements. Internal rotation (IR) and total arc ROM in the throwing shoulder (TS) decreased significantly (p handball players' shoulders changed significantly from the beginning to the end of a season. More specifically, the repetitive forces accumulated during the competitive season resulted in altered GIRD, ERG and isometric strength of the dominant glenohumeral joint.

  11. Comparison of Forced-Alignment Speech Recognition and Humans for Generating Reference VAD

    DEFF Research Database (Denmark)

    Kraljevski, Ivan; Tan, Zheng-Hua; Paola Bissiri, Maria

    2015-01-01

    This present paper aims to answer the question whether forced-alignment speech recognition can be used as an alternative to humans in generating reference Voice Activity Detection (VAD) transcriptions. An investigation of the level of agreement between automatic/manual VAD transcriptions and the ......This present paper aims to answer the question whether forced-alignment speech recognition can be used as an alternative to humans in generating reference Voice Activity Detection (VAD) transcriptions. An investigation of the level of agreement between automatic/manual VAD transcriptions...... and the reference ones produced by a human expert was carried out. Thereafter, statistical analysis was employed on the automatically produced and the collected manual transcriptions. Experimental results confirmed that forced-alignment speech recognition can provide accurate and consistent VAD labels....

  12. The proton motive force generated in Leuconostoc oenos by L-malate fermentation

    NARCIS (Netherlands)

    Salema, Madalena; Lolkema, Juke S.; San Romão, M.V.; Loureiro Dias, Maria C.

    In cells of Leuconostoc oenos, the fermentation of L-malic acid generates both a transmembrane pH gradient, inside alkaline, and an electrical potential gradient, inside negative. In resting cells, the proton motive force ranged from -170 mV to -88 mV between pH 3.1 and 5.6 in the presence of

  13. On convergence generation in computing the electro-magnetic Casimir force

    International Nuclear Information System (INIS)

    Schuller, F.

    2008-01-01

    We tackle the very fundamental problem of zero-point energy divergence in the context of the Casimir effect. We calculate the Casimir force due to field fluctuations by using standard cavity radiation modes. The validity of convergence generation by means of an exponential energy cut-off factor is discussed in detail. (orig.)

  14. A comparative assessment of forces and moments generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Katsaros, C.; Eliades, T.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded

  15. Cogging Force Issues of Permanent Magnet Linear Generator for Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Izzeldin Idris Abdalla

    2017-09-01

    Full Text Available Alternatives to hydraulic drives that used on vehicles are necessary in order to reduce the Carbon dioxide (CO2 emission and oil consumption. Hence better performance and efficiency of the vehicles can be achieved by using free piston engine, in which the piston reciprocate linearly with a permanent magnet linear generator (PMLG without the need of a crankshaft. The PMLG has high performance, but suffering from the cogging force. The cogging force induces undesired vibration and acoustic noise and makes a ripple in the thrust force. Moreover, the cogging force deteriorates the control characteristics, particularly in terms of the position control and speed precisely. This paper proposes Somaloy to replace the laminated silicon steel sheets in order to reduce the cogging force in a PMLG. Through a finite-element analysis, it has been shown that, the stator core made of Somaloy minimizes the cogging force of the PMLG, moreover, giving larger flux-linkage and back-electromotive force (B-EMF, respectively.

  16. Improvement of force factor of magnetostrictive vibration power generator for high efficiency

    International Nuclear Information System (INIS)

    Kita, Shota; Ueno, Toshiyuki; Yamada, Sotoshi

    2015-01-01

    We develop high power magnetostrictive vibration power generator for battery-free wireless electronics. The generator is based on a cantilever of parallel beam structure consisting of coil-wound Galfenol and stainless plates with permanent magnet for bias. Oscillating force exerted on the tip bends the cantilever in vibration yields stress variation of Galfenol plate, which causes flux variation and generates voltage on coil due to the law of induction. This generator has advantages over conventional, such as piezoelectric or moving magnet types, in the point of high efficiency, highly robust, and low electrical impedance. Our concern is the improvement of energy conversion efficiency dependent on the dimension. Especially, force factor, the conversion ratio of the electromotive force (voltage) on the tip velocity in vibration, has an important role in energy conversion process. First, the theoretical value of the force factor is formulated and then the validity was verified by experiments, where we compare four types of prototype with parameters of the dimension using 7.0 × 1.5 × 50 mm beams of Galfenol with 1606-turn wound coil. In addition, the energy conversion efficiency of the prototypes depending on load resistance was measured. The most efficient prototype exhibits the maximum instantaneous power of 0.73 W and energy of 4.7 mJ at a free vibration of frequency of 202 Hz in the case of applied force is 25 N. Further, it was found that energy conversion efficiency depends not only on the force factor but also on the damping (mechanical loss) of the vibration

  17. Assessment of Isometric Trunk Strength - The Relevance of Body Position and Relationship between Planes of Movement.

    Science.gov (United States)

    Kocjan, Andrej; Sarabon, Nejc

    2014-05-01

    The aim of the study was to assess the differences in maximal isometric trunk extension and flexion strength during standing, sitting and kneeling. Additionally, we were interested in correlations between the maximal strength in sagittal, frontal and transverse plane, measured in the sitting position. Sixty healthy subjects (24 male, 36 female; age 41.3 ± 15.1 yrs; body height 1.70 ± 0.09 m; body mass 72.7 ± 13.3 kg) performed maximal voluntary isometric contractions of the trunk flexor and extensor muscles in standing, sitting and kneeling position. The subjects also performed lateral flexions and rotations in the sitting position. Each task was repeated three times and average of maximal forces was used for data analysis. RANOVA with post-hoc testing was applied to the flexion and extension data. The level of statistical significance was set to p strength showed the strongest correlation, followed by frontal-transverse and sagittal-frontal plane correlation pairs (R(2) = 0.830, 0.712 and 0.657). The baseline trunk isometric strength data provided by this study should help further strength diagnostics, more precisely, the prevention of low back disorders. Key pointsMaximal voluntary isometric force of the trunk extensors increased with the angle at the hips (highest in sitting, medium in kneeling and lowest in upright standing).The opposite trend was true for isometric MVC force of trunk flexors (both genders together and men only).In the sitting position, the strongest correlation between MVC forces was found between sagittal (average flexion/extension) and transverse plane (average left/right rotation).IN ORDER TO INCREASE THE VALIDITY OF TRUNK STRENGTH TESTING THE LETTER SHOULD INCLUDE: specific warm-up, good pelvic fixation and visual feedback.

  18. Some isometrical identities in the wave equation

    Directory of Open Access Journals (Sweden)

    Saburou Saitoh

    1984-01-01

    Full Text Available We consider the usual wave equation utt(x,t=c2uxx(x,t on the real line with some typical initial and boundary conditions. In each case, we establish a natural isometrical identity and inverse formula between the sourse function and the response function.

  19. Experience of research, design, capacity, and operation with forced flow steam generators

    International Nuclear Information System (INIS)

    Bertolotti, G.; McDonald, B.N.; Pocock, F.J.

    1975-01-01

    The forced flow steam generators in operation in six American nuclear power plants show an excellent operational behaviour. The concept for this type of steam generator has been developed in the USA, and it has been successfully tested over several years regarding its suitability for PWRs of a larger size. The results concerning construction, materials and water chemistry for this steam generator, which will be used for the first time in the FRG in the nuclear power station Muelheim-Kaerlich, have confirmed the high reliability of this high-efficiency component. (orig./LN) [de

  20. Impact of pain reported during isometric quadriceps muscle strength testing in people with knee pain: data from the osteoarthritis initiative.

    Science.gov (United States)

    Riddle, Daniel L; Stratford, Paul W

    2011-10-01

    Muscle force testing is one of the more common categories of diagnostic tests used in clinical practice. Clinicians have little evidence to guide interpretations of muscle force tests when pain is elicited during testing. The purpose of this study was to examine the construct validity of isometric quadriceps muscle strength tests by determining whether the relationship between maximal isometric quadriceps muscle strength and functional status was influenced by pain during isometric testing. A cross-sectional design was used. Data from the Osteoarthritis Initiative were used to identify 1,344 people with unilateral knee pain and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale scores of 1 or higher on the involved side. Measurements of maximal isometric quadriceps strength and ratings of pain during isometric testing were collected. Outcome variables were WOMAC physical function subscale, 20-m walk test, 400-m walk test, and a repeated chair stand test. Multiple regression models were used to determine whether pain during testing modified or confounded the relationship between strength and functional status. Pearson r correlations among the isometric quadriceps strength measures and the 4 outcome measures ranged from -.36 (95% confidence interval=-.41, -.31) for repeated chair stands to .36 (95% confidence interval=.31, .41) for the 20-m walk test. In the final analyses, neither effect modification nor confounding was found for the repeated chair stand test, the 20-m walk test, the 400-m walk test, or the WOMAC physical function subscale. Moderate or severe pain during testing was weakly associated with reduced strength, but mild pain was not. The disease spectrum was skewed toward mild or moderate symptoms, and the pain measurement scale used during muscle force testing was not ideal. Given that the spectrum of the sample was skewed toward mild or moderate symptoms and disease, the data suggest that isometric quadriceps muscle

  1. Assessing Muscle-Strength Asymmetry via a Unilateral-Stance Isometric Midthigh Pull.

    Science.gov (United States)

    Dos'Santos, Thomas; Thomas, Christopher; Jones, Paul A; Comfort, Paul

    2017-04-01

    To investigate the within-session reliability of bilateral- and unilateral-stance isometric midthigh-pull (IMTP) force-time characteristics including peak force (PF), relative PF, and impulse at time bands (0-100, 0-200, 0-250, and 0-300 milliseconds) and to compare isometric force-time characteristics between right and left and dominant (D) and nondominant (ND) limbs. Professional male rugby league and multisport male college athletes (N = 54; age, 23.4 ± 4.2 y; height, 1.80 ± 0.05 m; mass, 88.9 ± 12.9 kg) performed 3 bilateral IMTP trials and 6 unilateral-stance IMTP trials (3 per leg) on a force plate sampling at 600 Hz. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) demonstrated high within-session reliability for bilateral and unilateral IMTP PF (ICC = .94, CV = 4.7-5.5%). Lower reliability measures and greater variability were observed for bilateral and unilateral IMTP impulse at time bands (ICC = .81-.88, CV = 7.7-11.8%). Paired-sample t tests and Cohen d effect sizes revealed no significant differences for all isometric force-time characteristics between right and left limbs in male college athletes (P >.05, d ≤ 0.32) and professional rugby league players (P > .05, d ≤ 0.11); however, significant differences were found between D and ND limbs in male college athletes (P isometric force-time characteristics between D and ND limbs in male athletes.

  2. Change Agent – A Force Generating Resistance To Change Within An Organization?

    Directory of Open Access Journals (Sweden)

    Mariana Prediscan

    2012-12-01

    Full Text Available The purpose of this research is to identify if the change agent represents or not a force generating resistance to change within an organization. The employees affected by a change process are usually the ones who oppose to new implementations. Their opposition is bigger or smaller, depending on the extent that they are affected and also by the direction, either positive or negative. However, employee’s opposition can be potentiated or reduced, depending on the manifestation of the following forces within an organization: communications, the type of organizational structure, management style and organizational culture, forces which refer to the organizational climate. To answer our question, we have researched the current literature and discovered that the change agent can represent a force generating resistance to change within an organization in those situations when he or she identifies with a middle or top manager from the organizational pyramid. This information is valuable to researchers and practitioners, as for a long time, employees were considered the only ones manifesting resistance, the possibility that the change agent can oppose new changes being ignored.

  3. Generation of a strong core-centering force in a submillimeter compound droplet system

    International Nuclear Information System (INIS)

    Lee, M.C.; Feng, I.; Elleman, D.D.; Wang, T.G.; Young, A.T.

    1981-01-01

    By amplitude-modulating the driving voltage of an acoustic levitating apparatus, a strong core-centering force can be generated in a submillimeter compound droplet system suspended by the radiation pressure in a gaseous medium. Depending on the acoustic characteristics of the droplet system, it has been found that the technique can be utilized advantageously in the multiple-layer coating of an inertial-confinement-fusion pellet

  4. Generated forces and heat during the critical stages of friction stir welding and processing

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Sadiq Aziz; Tahir, Abd Salam Md; Izamshah, R. [University Teknikal Malaysia Melaka, Malacca (Malaysia)

    2015-10-15

    The solid-state behavior of friction stir welding process results in violent mechanical forces that should be mitigated, if not eliminated. Plunging and dwell time are the two critical stages of this welding process in terms of the generated forces and the related heat. In this study, several combinations of pre-decided penetration speeds, rotational speeds, tool designs, and dwell time periods were used to investigate these two critical stages. Moreover, a coupled-field thermal-structural finite element model was developed to validate the experimental results and the induced stresses. The experimental results revealed the relatively large changes in force and temperature during the first two stages compared with those during the translational tool movement stage. An important procedure to mitigate the undesired forces was then suggested. The model prediction of temperature values and their distribution were in good agreement with the experimental prediction. Therefore, the thermal history of this non-uniform heat distribution was used to estimate the induced thermal stresses. Despite the 37% increase in these stresses when 40 s dwell time was used instead of 5 s, these stresses showed no effect on the axial force values because of the soft material incidence and stir effects.

  5. Generated forces and heat during the critical stages of friction stir welding and processing

    International Nuclear Information System (INIS)

    Hussein, Sadiq Aziz; Tahir, Abd Salam Md; Izamshah, R.

    2015-01-01

    The solid-state behavior of friction stir welding process results in violent mechanical forces that should be mitigated, if not eliminated. Plunging and dwell time are the two critical stages of this welding process in terms of the generated forces and the related heat. In this study, several combinations of pre-decided penetration speeds, rotational speeds, tool designs, and dwell time periods were used to investigate these two critical stages. Moreover, a coupled-field thermal-structural finite element model was developed to validate the experimental results and the induced stresses. The experimental results revealed the relatively large changes in force and temperature during the first two stages compared with those during the translational tool movement stage. An important procedure to mitigate the undesired forces was then suggested. The model prediction of temperature values and their distribution were in good agreement with the experimental prediction. Therefore, the thermal history of this non-uniform heat distribution was used to estimate the induced thermal stresses. Despite the 37% increase in these stresses when 40 s dwell time was used instead of 5 s, these stresses showed no effect on the axial force values because of the soft material incidence and stir effects

  6. The effect of 6 days of alpha glycerylphosphorylcholine on isometric strength.

    Science.gov (United States)

    Bellar, David; LeBlanc, Nina R; Campbell, Brian

    2015-01-01

    Ergogenic aides are widely used by fitness enthusiasts and athletes to increase performance. Alpha glycerylphosphorylcholine (A-GPC) has demonstrated some initial promise in changing explosive performance. The purpose of the present investigation was to determine if 6 days of supplementation with A-GPC would augment isometric force production compared to a placebo. Thirteen college-aged males (Means ± SD; Age: 21.9 ± 2.2 years, Height: 180.3 ± 7.7 cm, Weight: 87.6 ± 15.6 kg; VO2 max: 40.08 ± 7.23 ml O2*Kg(-1)*min(-1), Body Fat: 17.5 ± 4.6%) gave written informed consent to participate in the study. The study was a double blind, placebo controlled, cross-over design. The participants reported to the lab for an initial visit where they were familiarized with the isometric mid thigh pull in a custom squat cage on a force platform and upper body isometric test against a high frequency load cell, and baseline measurements were taken for both. The participant then consumed either 600 mg per day of A-GPC or placebo and at the end of 6 days performed isometric mid thigh pulls and an upper body isometric test. A one-week washout period was used before the participants' baseline was re-measured and crossed over to the other treatment. The A-GPC treatment resulted in significantly greater isometric mid thigh pull peak force change from baseline (t = 1.76, p = 0.044) compared with placebo (A-GPC: 98.8. ± 236.9 N vs Placebo: -39.0 ± 170.9 N). For the upper body test the A-GPC treatment trended towards greater change from baseline force production (A-GPC: 50.9 ± 67.2 N Placebo: -14.9 ± 114.9 N) but failed to obtain statistical significance (t = 1.16, p = 0.127). A-GPC is effective at increasing lower body force production after 6 days of supplementation. Sport performance coaches can consider adding A-GPC to the diet of speed and power athletes to enhance muscle performance.

  7. Recent Developments in Grid Generation and Force Integration Technology for Overset Grids

    Science.gov (United States)

    Chan, William M.; VanDalsem, William R. (Technical Monitor)

    1994-01-01

    Recent developments in algorithms and software tools for generating overset grids for complex configurations are described. These include the overset surface grid generation code SURGRD and version 2.0 of the hyperbolic volume grid generation code HYPGEN. The SURGRD code is in beta test mode where the new features include the capability to march over a collection of panel networks, a variety of ways to control the side boundaries and the marching step sizes and distance, a more robust projection scheme and an interpolation option. New features in version 2.0 of HYPGEN include a wider range of boundary condition types. The code also allows the user to specify different marching step sizes and distance for each point on the surface grid. A scheme that takes into account of the overlapped zones on the body surface for the purpose of forces and moments computation is also briefly described, The process involves the following two software modules: MIXSUR - a composite grid generation module to produce a collection of quadrilaterals and triangles on which pressure and viscous stresses are to be integrated, and OVERINT - a forces and moments integration module.

  8. Identification by force modulation microscopy of nanoparticles generated in vacuum arcs Identification by force modulation microscopy of nanoparticles generated in vacuum arcs

    Directory of Open Access Journals (Sweden)

    M. Arroyave Franco

    2006-06-01

    Full Text Available An alternative method based on force modulation microscopy (FMM for identification of nanoparticles produced in the plasma generated by the cathode spots of vacuum arcs is presented. FMM technique is enabled for the detection of variations in the mechanical properties of a surface with high sensitiveness. Titanium nitride (TiN coatings deposited on oriented silicon by pulsed vacuum arc process have been analyzed. AFM (Atomic Force Microscopy and FMM images were simultaneously obtained, and in all cases it was possible to identify nanoparticle presence. Further X-ray Diffraction spectra of sample coating were taken. Existence of contaminant particles of 47 nanometers in diameter was reported.En este trabajo se presenta un método alternativo basado en microscopia de modulación de fuerza (FMM, para la identificación de nanogotas producidas en el plasma generado por los spots catódicos de los arcos en vacío. La técnica FMM esta habilitada para la detección de variaciones en las propiedades mecánicas de una superficie, con alta sensibilidad. Se han analizado recubrimientos de nitruro de titanio (TiN depositados sobre Silicio orientado por el proceso de arco en vacío pulsado. Se han obtenido simultáneamente imágenes de microscopia de fuerza atómica (AFM y de microscopia FMM mediante las cuales se ha podido identificar la presencia de nanogotas. Adicionalmente se han tomado espectros de difracción de rayos X (XRD de las muestras recubiertas. Se ha reportado la existencia de partículas contaminantes de 47 nanómetros de diámetro sobre los recubrimientos.

  9. Isometric strength training lowers the O2 cost of cycling during moderate-intensity exercise.

    Science.gov (United States)

    Zoladz, Jerzy A; Szkutnik, Zbigniew; Majerczak, Joanna; Grandys, Marcin; Duda, Krzysztof; Grassi, Bruno

    2012-12-01

    The effect of maximal voluntary isometric strength training of knee extensor muscles on pulmonary V'O(2) on-kinetics, the O(2) cost of cycling and peak oxygen uptake (V'O(2peak)) in humans was studied. Seven healthy males (mean ± SD, age 22.3 ± 2.0 years, body weight 75.0 ± 9.2 kg, V'O(2peak) 49.5 ± 3.8 ml kg(-1) min(-1)) performed maximal isometric strength training lasting 7 weeks (4 sessions per week). Force during maximal voluntary contraction (MVC) increased by 15 % (P Strength training resulted in a significant decrease (by ~7 %; P Isometric strength training rapidly (i.e., after 1 week) decreases the O(2) cost of cycling during moderate-intensity exercise, whereas it does not affect the amplitude of the slow component of the V'O(2) on-kinetics during heavy-intensity exercise. Isometric strength training can have beneficial effects on performance during endurance events.

  10. Explicit polarization: a quantum mechanical framework for developing next generation force fields.

    Science.gov (United States)

    Gao, Jiali; Truhlar, Donald G; Wang, Yingjie; Mazack, Michael J M; Löffler, Patrick; Provorse, Makenzie R; Rehak, Pavel

    2014-09-16

    Conspectus Molecular mechanical force fields have been successfully used to model condensed-phase and biological systems for a half century. By means of careful parametrization, such classical force fields can be used to provide useful interpretations of experimental findings and predictions of certain properties. Yet, there is a need to further improve computational accuracy for the quantitative prediction of biomolecular interactions and to model properties that depend on the wave functions and not just the energy terms. A new strategy called explicit polarization (X-Pol) has been developed to construct the potential energy surface and wave functions for macromolecular and liquid-phase simulations on the basis of quantum mechanics rather than only using quantum mechanical results to fit analytic force fields. In this spirit, this approach is called a quantum mechanical force field (QMFF). X-Pol is a general fragment method for electronic structure calculations based on the partition of a condensed-phase or macromolecular system into subsystems ("fragments") to achieve computational efficiency. Here, intrafragment energy and the mutual electronic polarization of interfragment interactions are treated explicitly using quantum mechanics. X-Pol can be used as a general, multilevel electronic structure model for macromolecular systems, and it can also serve as a new-generation force field. As a quantum chemical model, a variational many-body (VMB) expansion approach is used to systematically improve interfragment interactions, including exchange repulsion, charge delocalization, dispersion, and other correlation energies. As a quantum mechanical force field, these energy terms are approximated by empirical functions in the spirit of conventional molecular mechanics. This Account first reviews the formulation of X-Pol, in the full variationally correct version, in the faster embedded version, and with systematic many-body improvements. We discuss illustrative examples

  11. An Investigation Into the Relationship Between Maximum Isometric Strength and Vertical Jump Performance.

    Science.gov (United States)

    Thomas, Christopher; Jones, Paul A; Rothwell, James; Chiang, Chieh Y; Comfort, Paul

    2015-08-01

    Research has demonstrated a clear relationship between dynamic strength and vertical jump (VJ) performance; however, the relationship of isometric strength and VJ performance has been studied less extensively. The aim of this study was to determine the relationship between isometric strength and performance during the squat jump (SJ) and countermovement jump (CMJ). Twenty-two male collegiate athletes (mean ± SD; age = 21.3 ± 2.9 years; height = 175.63 ± 8.23 cm; body mass = 78.06 ± 10.77 kg) performed isometric midthigh pulls (IMTPs) to assess isometric peak force (IPF), maximum rate of force development, and impulse (IMP) (I100, I200, and I300). Force-time data, collected during the VJs, were used to calculate peak velocity, peak force (PF), peak power (PP), and jump height. Absolute IMTP measures of IMP showed the strongest correlations with VJ PF (r = 0.43-0.64; p ≤ 0.05) and VJ PP (r = 0.38-0.60; p ≤ 0.05). No statistical difference was observed in CMJ height (0.33 ± 0.05 m vs. 0.36 ± 0.05 m; p = 0.19; ES = -0.29) and SJ height performance (0.29 ± 0.06 m vs. 0.33 ± 0.05 m; p = 0.14; ES = -0.34) when comparing stronger to weaker athletes. The results of this study illustrate that absolute IPF and IMP are related to VJ PF and PP but not VJ height. Because stronger athletes did not jump higher than weaker athletes, dynamic strength tests may be more practical methods of assessing the relationships between relative strength levels and dynamic performance in collegiate athletes.

  12. Acoustic manipulation of active spherical carriers: Generation of negative radiation force

    Energy Technology Data Exchange (ETDEWEB)

    Rajabi, Majid, E-mail: majid_rajabi@iust.ac.ir; Mojahed, Alireza

    2016-09-15

    This paper examines theoretically a novel mechanism of generating negative (pulling) radiation force for acoustic manipulation of spherical carriers equipped with piezoelectric actuators in its inner surface. In this mechanism, the spherical particle is handled by common plane progressive monochromatic acoustic waves instead of zero-/higher- order Bessel beams or standing waves field. The handling strategy is based on applying a spatially uniform harmonic electrical voltage at the piezoelectric actuator with the same frequency of handling acoustic waves, in order to change the radiation force effect from repulsive (away from source) to attractive (toward source). This study may be considered as a start point for development of contact-free precise handling and entrapment technology of active carriers which are essential in many engineering and medicine applications.

  13. Influenece of the CPRmeter on angular position of elbows and generated forces during cardiopulmonary resuscitation

    Directory of Open Access Journals (Sweden)

    Karolina Kopacz

    2017-10-01

    Full Text Available Objectives: It is commonly known that ergonomics in emergency medical services (EMS is very important. Emergency medical services workers are exposed to different conditions and they should perform a variety of tasks. Material and Methods: The aim of the work has been to analyze the angular position of elbows and forces generated by the upper limbs during cardiopulmonary resuscitation with and without the CPRmeter based on feedback technology. Ten male paramedics and 10 male non-paramedics, in a kneeling position, performed cardiopulmonary resuscitation (CPR on an Ambu Megacode manikin placed on the ground. Measurements were taken after 1 min and 4 min following the beginning of the trial. The angular position of the elbows was evaluated with a BTS Smart DX 7000 motion capture system. Kistler platforms 9286BA were used for measuring forces. Results: In the paramedic group, one statistically significant difference was observed in the mean difference between maximal and minimal right elbow angle in the 1st min without the device vs. the mean difference in the 4th min without the device. In the paramedic group, a 25% force decrease was observed after 4 min of resuscitation in trials without the CPRmeter in comparison to the 1st min. In trials with the CPRmeter, the force parameters were similar in the 1st and 4th min and more stable. No statistically significant differences were noticed in the control group. Conclusions: The CPRmeter has influence on the magnitude of the forces applied by the upper limbs and on the optimization of the rescuer effort during cardiopulmonary resuscitation. The CPRmeter had no influence on the position of the upper part of the kinematic chain. Int J Occup Med Environ Health 2017;30(6:909–916

  14. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    Science.gov (United States)

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  15. Isometric Reflection Vectors and Characterizations of Hilbert Spaces

    Directory of Open Access Journals (Sweden)

    Donghai Ji

    2014-01-01

    Full Text Available A known characterization of Hilbert spaces via isometric reflection vectors is based on the following implication: if the set of isometric reflection vectors in the unit sphere SX of a Banach space X has nonempty interior in SX, then X is a Hilbert space. Applying a recent result based on well-known theorem of Kronecker from number theory, we improve this by substantial reduction of the set of isometric reflection vectors needed in the hypothesis.

  16. Isometric exercise: cardiovascular responses in normal and cardiac populations.

    Science.gov (United States)

    Hanson, P; Nagle, F

    1987-05-01

    Isometric exercise produces a characteristic pressor increase in blood pressure which may be important in maintaining perfusion of muscle during sustained contraction. This response is mediated by combined central and peripheral afferent input to medullary cardiovascular centers. In normal individuals the increase in blood pressure is mediated by a rise in cardiac output with little or no change in systemic vascular resistance. However, the pressor response is also maintained during pharmacologic blockade or surgical denervation by increasing systemic vascular resistance. Left ventricular function is normally maintained or improves in normal subjects and cardiac patients with mild impairment of left ventricular contractility. Patients with poor left ventricular function may show deterioration during isometric exercise, although this pattern of response is difficult to predict from resting studies. Recent studies have shown that patients with uncomplicated myocardial infarction can perform submaximum isometric exercise such as carrying weights in the range of 30 to 50 lb without difficulty or adverse responses. In addition, many patients who show ischemic ST depression or angina during dynamic exercise may have a reduced ischemic response during isometric or combined isometric and dynamic exercise. Isometric exercises are frequently encountered in activities of daily living and many occupational tasks. Cardiac patients should be gradually exposed to submaximum isometric training in supervised cardiac rehabilitation programs. Specific job tasks that require isometric or combined isometric and dynamic activities may be evaluated by work simulation studies. This approach to cardiac rehabilitation may facilitate patients who wish to return to a job requiring frequent isometric muscle contraction. Finally, there is a need for additional research on the long-term effects of isometric exercise training on left ventricular hypertrophy and performance. The vigorous training

  17. Bolt Shear Force Sensor

    Science.gov (United States)

    2015-03-12

    0030] FIG. 7 is an isometric view of a deformable ring of the bolt shear force sensor of the present invention with an optical Attorney Docket No...102587 9 of 19 fiber having Bragg gratings wound around the ring; [0031] FIG. 8 is an isometric view of the deformable ring with wire strain... strength . [0047] Once the joint is subjected to an external load (see force arrows “F” and “F/2”); any frictional resistance to slip is overcome and

  18. Experimental study of tube/support impact forces in multi-span PWR steam generator tubes

    International Nuclear Information System (INIS)

    Axisa, F.; Desseaux, A.; Gibert, R.J.

    1984-12-01

    The vibro-impact response of a straight part of a steam generator tube is investigated experimentally and using numerical simulation with the aim to relate tube overall dynamics with excitation and tube-support clearance. Configuration studied here corresponds to the tube being excited in only one direction at its first resonance presenting an antinode of vibration at the impacted support. Tests show namely that midspan displacement of tube is almost proportional to excitation level and clearance. Impact forces averaged over a cycle of vibration are almost proportional to excitation and poorly dependent on clearance. Results of numerical simulation are in fairly good agreement with test results

  19. Kinetic coupling of phosphate release, force generation and rate-limiting steps in the cross-bridge cycle.

    Science.gov (United States)

    Stehle, Robert; Tesi, Chiara

    2017-08-01

    A basic goal in muscle research is to understand how the cyclic ATPase activity of cross-bridges is converted into mechanical force. A direct approach to study the chemo-mechanical coupling between P i release and the force-generating step is provided by the kinetics of force response induced by a rapid change in [P i ]. Classical studies on fibres using caged-P i discovered that rapid increases in [P i ] induce fast force decays dependent on final [P i ] whose kinetics were interpreted to probe a fast force-generating step prior to P i release. However, this hypothesis was called into question by studies on skeletal and cardiac myofibrils subjected to P i jumps in both directions (increases and decreases in [P i ]) which revealed that rapid decreases in [P i ] trigger force rises with slow kinetics, similar to those of calcium-induced force development and mechanically-induced force redevelopment at the same [P i ]. A possible explanation for this discrepancy came from imaging of individual sarcomeres in cardiac myofibrils, showing that the fast force decay upon increase in [P i ] results from so-called sarcomere 'give'. The slow force rise upon decrease in [P i ] was found to better reflect overall sarcomeres cross-bridge kinetics and its [P i ] dependence, suggesting that the force generation coupled to P i release cannot be separated from the rate-limiting transition. The reasons for the different conclusions achieved in fibre and myofibril studies are re-examined as the recent findings on cardiac myofibrils have fundamental consequences for the coupling between P i release, rate-limiting steps and force generation. The implications from P i -induced force kinetics of myofibrils are discussed in combination with historical and recent models of the cross-bridge cycle.

  20. Measurement of the impuslive force generated by colapsing bubble close to a solid boundary

    Directory of Open Access Journals (Sweden)

    Zima Patrik

    2012-04-01

    Full Text Available The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power led diode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.

  1. Metabolic costs of force generation for constant-frequency and catchlike-inducing electrical stimulation in human tibialis anterior muscle

    DEFF Research Database (Denmark)

    Ratkevicius, Aivaras; Quistorff, Bjørn

    2002-01-01

    -frequency trains, catchlike-inducing trains produced a faster force generation and were more effective in maintaining the force--time integral as well as peak force. However, ATP costs of force generation were similar for the catchlike-inducing and constant-frequency stimulation (6.7 plus/minus 1.1 and 6.6 plus......Metabolic costs of force generation were compared for constant-frequency and catchlike-inducing electrical stimulation. Repetitive catchlike-inducing trains consisted of 2 interpulse intervals (IPIs) at 12.5 ms, 1 IPI at 25 ms, and 5 IPIs at 50 ms. Constant-frequency trains consisted of 8 IPIs...... at 37.5 ms. One train was delivered to the peroneal nerve every 2.5 s for 36 times under ischemic conditions. Anaerobic adenosine triphosphate (ATP) turnover was determined using 31-phosphorus magnetic resonance spectroscopy (P-MRS) of the human tibialis anterior muscle. Compared with constant...

  2. Easy Volcanic Aerosol (EVA v1.0: an idealized forcing generator for climate simulations

    Directory of Open Access Journals (Sweden)

    M. Toohey

    2016-11-01

    Full Text Available Stratospheric sulfate aerosols from volcanic eruptions have a significant impact on the Earth's climate. To include the effects of volcanic eruptions in climate model simulations, the Easy Volcanic Aerosol (EVA forcing generator provides stratospheric aerosol optical properties as a function of time, latitude, height, and wavelength for a given input list of volcanic eruption attributes. EVA is based on a parameterized three-box model of stratospheric transport and simple scaling relationships used to derive mid-visible (550 nm aerosol optical depth and aerosol effective radius from stratospheric sulfate mass. Precalculated look-up tables computed from Mie theory are used to produce wavelength-dependent aerosol extinction, single scattering albedo, and scattering asymmetry factor values. The structural form of EVA and the tuning of its parameters are chosen to produce best agreement with the satellite-based reconstruction of stratospheric aerosol properties following the 1991 Pinatubo eruption, and with prior millennial-timescale forcing reconstructions, including the 1815 eruption of Tambora. EVA can be used to produce volcanic forcing for climate models which is based on recent observations and physical understanding but internally self-consistent over any timescale of choice. In addition, EVA is constructed so as to allow for easy modification of different aspects of aerosol properties, in order to be used in model experiments to help advance understanding of what aspects of the volcanic aerosol are important for the climate system.

  3. Generating Converged Accurate Free Energy Surfaces for Chemical Reactions with a Force-Matched Semiempirical Model.

    Science.gov (United States)

    Kroonblawd, Matthew P; Pietrucci, Fabio; Saitta, Antonino Marco; Goldman, Nir

    2018-04-10

    We demonstrate the capability of creating robust density functional tight binding (DFTB) models for chemical reactivity in prebiotic mixtures through force matching to short time scale quantum free energy estimates. Molecular dynamics using density functional theory (DFT) is a highly accurate approach to generate free energy surfaces for chemical reactions, but the extreme computational cost often limits the time scales and range of thermodynamic states that can feasibly be studied. In contrast, DFTB is a semiempirical quantum method that affords up to a thousandfold reduction in cost and can recover DFT-level accuracy. Here, we show that a force-matched DFTB model for aqueous glycine condensation reactions yields free energy surfaces that are consistent with experimental observations of reaction energetics. Convergence analysis reveals that multiple nanoseconds of combined trajectory are needed to reach a steady-fluctuating free energy estimate for glycine condensation. Predictive accuracy of force-matched DFTB is demonstrated by direct comparison to DFT, with the two approaches yielding surfaces with large regions that differ by only a few kcal mol -1 .

  4. Experimental and theoretical analysis of a hybrid solar thermoelectric generator with forced convection cooling

    Science.gov (United States)

    Sundarraj, Pradeepkumar; Taylor, Robert A.; Banerjee, Debosmita; Maity, Dipak; Sinha Roy, Susanta

    2017-01-01

    Hybrid solar thermoelectric generators (HSTEGs) have garnered significant research attention recently due to their potential ability to cogenerate heat and electricity. In this paper, theoretical and experimental investigations of the electrical and thermal performance of a HSTEG system are reported. In order to validate the theoretical model, a laboratory scale HSTEG system (based on forced convection cooling) is developed. The HSTEG consists of six thermoelectric generator modules, an electrical heater, and a stainless steel cooling block. Our experimental analysis shows that the HSTEG is capable of producing a maximum electrical power output of 4.7 W, an electrical efficiency of 1.2% and thermal efficiency of 61% for an average temperature difference of 92 °C across the TEG modules with a heater power input of 382 W. These experimental results of the HSTEG system are found to be in good agreement with the theoretical prediction. This experimental/theoretical analysis can also serve as a guide for evaluating the performance of the HSTEG system with forced convection cooling.

  5. Assessing the accuracy of subject-specific, muscle-model parameters determined by optimizing to match isometric strength.

    Science.gov (United States)

    DeSmitt, Holly J; Domire, Zachary J

    2016-12-01

    Biomechanical models are sensitive to the choice of model parameters. Therefore, determination of accurate subject specific model parameters is important. One approach to generate these parameters is to optimize the values such that the model output will match experimentally measured strength curves. This approach is attractive as it is inexpensive and should provide an excellent match to experimentally measured strength. However, given the problem of muscle redundancy, it is not clear that this approach generates accurate individual muscle forces. The purpose of this investigation is to evaluate this approach using simulated data to enable a direct comparison. It is hypothesized that the optimization approach will be able to recreate accurate muscle model parameters when information from measurable parameters is given. A model of isometric knee extension was developed to simulate a strength curve across a range of knee angles. In order to realistically recreate experimentally measured strength, random noise was added to the modeled strength. Parameters were solved for using a genetic search algorithm. When noise was added to the measurements the strength curve was reasonably recreated. However, the individual muscle model parameters and force curves were far less accurate. Based upon this examination, it is clear that very different sets of model parameters can recreate similar strength curves. Therefore, experimental variation in strength measurements has a significant influence on the results. Given the difficulty in accurately recreating individual muscle parameters, it may be more appropriate to perform simulations with lumped actuators representing similar muscles.

  6. Molecular interactions and residues involved in force generation in the T4 viral DNA packaging motor.

    Science.gov (United States)

    Migliori, Amy D; Smith, Douglas E; Arya, Gaurav

    2014-12-12

    Many viruses utilize molecular motors to package their genomes into preformed capsids. A striking feature of these motors is their ability to generate large forces to drive DNA translocation against entropic, electrostatic, and bending forces resisting DNA confinement. A model based on recently resolved structures of the bacteriophage T4 motor protein gp17 suggests that this motor generates large forces by undergoing a conformational change from an extended to a compact state. This transition is proposed to be driven by electrostatic interactions between complementarily charged residues across the interface between the N- and C-terminal domains of gp17. Here we use atomistic molecular dynamics simulations to investigate in detail the molecular interactions and residues involved in such a compaction transition of gp17. We find that although electrostatic interactions between charged residues contribute significantly to the overall free energy change of compaction, interactions mediated by the uncharged residues are equally if not more important. We identify five charged residues and six uncharged residues at the interface that play a dominant role in the compaction transition and also reveal salt bridging, van der Waals, and solvent hydrogen-bonding interactions mediated by these residues in stabilizing the compact form of gp17. The formation of a salt bridge between Glu309 and Arg494 is found to be particularly crucial, consistent with experiments showing complete abrogation in packaging upon Glu309Lys mutation. The computed contributions of several other residues are also found to correlate well with single-molecule measurements of impairments in DNA translocation activity caused by site-directed mutations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Análisis de la fuerza isométrica en la propulsión y tracción en slalom en silla de ruedas y su relación con el rendimiento y la clasificación funcional. [Isometric force in wheelchair slalom during traction and propulsion and their relationship with performance and functional classification].

    Directory of Open Access Journals (Sweden)

    Raúl Reina

    2013-10-01

    profiles of the Cerebral Palsy International Sports and Recreation Association, took part in the study (5 ♂ and 4 ♀. Participants performed two maximal isometric force tests (propulsion and traction with their competition wheelchairs in which maximum force (Fmax, average force (Fmed, execution time and time used to reach different Fmax percentages were recorded. In addition, participants carried out two specific performance tests: a 16 m linear sprint with an inversion door after 8 m; and two 4 m linear displacements with a zig-zag round trip. The measured variable was execution time using photocell gates. Significant differences were found between D3 and D4 in propulsion tests for Fmax (p = 0,007 and Fmean (p = 0,002, being this last one higher. Significant statistical differences were found between D2 and D3 in specific performance tests (inversion: p = 0,034 and zig-zag: p = 0,010, being D3 the quickest group. Results show a non-linear relationship between classification divisions and the performance.http://dx.doi.org/10.5232/ricyde2013.03402

  8. Gear Shifting of Quadriceps during Isometric Knee Extension Disclosed Using Ultrasonography.

    Science.gov (United States)

    Zhang, Shu; Huang, Weijian; Zeng, Yu; Shi, Wenxiu; Diao, Xianfen; Wei, Xiguang; Ling, Shan

    2018-01-01

    Ultrasonography has been widely employed to estimate the morphological changes of muscle during contraction. To further investigate the motion pattern of quadriceps during isometric knee extensions, we studied the relative motion pattern between femur and quadriceps under ultrasonography. An interesting observation is that although the force of isometric knee extension can be controlled to change almost linearly, femur in the simultaneously captured ultrasound video sequences has several different piecewise moving patterns. This phenomenon is like quadriceps having several forward gear ratios like a car starting from rest towards maximal voluntary contraction (MVC) and then returning to rest. Therefore, to verify this assumption, we captured several ultrasound video sequences of isometric knee extension and collected the torque/force signal simultaneously. Then we extract the shapes of femur from these ultrasound video sequences using video processing techniques and study the motion pattern both qualitatively and quantitatively. The phenomenon can be seen easier via a comparison between the torque signal and relative spatial distance between femur and quadriceps. Furthermore, we use cluster analysis techniques to study the process and the clustering results also provided preliminary support to the conclusion that, during both ramp increasing and decreasing phases, quadriceps contraction may have several forward gear ratios relative to femur.

  9. Isometric multipliers of a vector valued Beurling algebra on a ...

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences; Volume 127; Issue 1. Isometric multipliers of a vector valued Beurling algebra on a discrete semigroup. Research Article Volume 127 Issue 1 February 2017 pp 109- ... Keywords. Weighted semigroup; multipliers of a semigroup; Beurling algebra; isometric multipliers.

  10. Impact of Isometric Contraction of Anterior Cervical Muscles on Cervical Lordosis.

    Science.gov (United States)

    Fedorchuk, Curtis A; McCoy, Matthew; Lightstone, Douglas F; Bak, David A; Moser, Jacque; Kubricht, Brett; Packer, John; Walton, Dustin; Binongo, Jose

    2016-09-01

    This study investigates the impact of isometric contraction of anterior cervical muscles on cervical lordosis. 29 volunteers were randomly assigned to an anterior head translation (n=15) or anterior head flexion (n=14) group. Resting neutral lateral cervical x-rays were compared to x-rays of sustained isometric contraction of the anterior cervical muscles producing anterior head translation or anterior head flexion. Paired sample t-tests indicate no significant difference between pre and post anterior head translation or anterior head flexion. Analysis of variance suggests that gender and peak force were not associated with change in cervical lordosis. Chamberlain's to atlas plane line angle difference was significantly associated with cervical lordosis difference during anterior head translation (p=0.01). This study shows no evidence that hypertonicity, as seen in muscle spasms, of the muscles responsible for anterior head translation and anterior head flexion have a significant impact on cervical lordosis.

  11. Effect of age and gender on the surface electromyogram during various levels of isometric contraction.

    Science.gov (United States)

    Arjunan, Sridhar; Kumar, Dinesh; Kalra, Chandan; Burne, John; Bastos, Teodiano

    2011-01-01

    This study reports the effects of age and gender on the surface electromyogram while performing isometric contraction. Experiments were conducted with two age groups--Young (Age: 20-29) and Old (Age: 60-69) where they performed sustained isometric contractions at various force levels (50%, 75%, 100% of maximum voluntary contraction). Traditional features such as root mean square (RMS) and median frequency (MDF) were computed from the recorded sEMG. The result indicates that the MDF of sEMG was not significantly affected by age, but was impacted by gender in both age groups. Also there was a significant change in the RMS of sEMG with age and gender at all levels of contraction. The results also indicate a large inter-subject variation. This study will provide an understanding of the underlying physiological effects of muscle contraction and muscle fatigue in different cohorts.

  12. Auxotonic to isometric contraction transitioning in a beating heart causes myosin step-size to down shift.

    Directory of Open Access Journals (Sweden)

    Thomas P Burghardt

    Full Text Available Myosin motors in cardiac ventriculum convert ATP free energy to the work of moving blood volume under pressure. The actin bound motor cyclically rotates its lever-arm/light-chain complex linking motor generated torque to the myosin filament backbone and translating actin against resisting force. Previous research showed that the unloaded in vitro motor is described with high precision by single molecule mechanical characteristics including unitary step-sizes of approximately 3, 5, and 8 nm and their relative step-frequencies of approximately 13, 50, and 37%. The 3 and 8 nm unitary step-sizes are dependent on myosin essential light chain (ELC N-terminus actin binding. Step-size and step-frequency quantitation specifies in vitro motor function including duty-ratio, power, and strain sensitivity metrics. In vivo, motors integrated into the muscle sarcomere form the more complex and hierarchically functioning muscle machine. The goal of the research reported here is to measure single myosin step-size and step-frequency in vivo to assess how tissue integration impacts motor function. A photoactivatable GFP tags the ventriculum myosin lever-arm/light-chain complex in the beating heart of a live zebrafish embryo. Detected single GFP emission reports time-resolved myosin lever-arm orientation interpreted as step-size and step-frequency providing single myosin mechanical characteristics over the active cycle. Following step-frequency of cardiac ventriculum myosin transitioning from low to high force in relaxed to auxotonic to isometric contraction phases indicates that the imposition of resisting force during contraction causes the motor to down-shift to the 3 nm step-size accounting for >80% of all the steps in the near-isometric phase. At peak force, the ATP initiated actomyosin dissociation is the predominant strain inhibited transition in the native myosin contraction cycle. The proposed model for motor down-shifting and strain sensing involves ELC N

  13. Evaluation of the friction force generated by monocristalyne and policristalyne ceramic brackets in sliding mechanics.

    Science.gov (United States)

    Pimentel, Roberta Ferreira; de Oliveira, Roberto Sotto Maior Fortes; Chaves, Maria das Graças Afonso Miranda; Elias, Carlos Nelson; Gravina, Marco Abdo

    2013-01-01

    To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.

  14. Receptor-mediated endocytosis generates nanomechanical force reflective of ligand identity and cellular property.

    Science.gov (United States)

    Zhang, Xiao; Ren, Juan; Wang, Jingren; Li, Shixie; Zou, Qingze; Gao, Nan

    2018-08-01

    Whether environmental (thermal, chemical, and nutrient) signals generate quantifiable, nanoscale, mechanophysical changes in the cellular plasma membrane has not been well elucidated. Assessment of such mechanophysical properties of plasma membrane may shed lights on fundamental cellular process. Atomic force microscopic (AFM) measurement of the mechanical properties of live cells was hampered by the difficulty in accounting for the effects of the cantilever motion and the associated hydrodynamic force on the mechanical measurement. These challenges have been addressed in our recently developed control-based AFM nanomechanical measurement protocol, which enables a fast, noninvasive, broadband measurement of the real-time changes in plasma membrane elasticity in live cells. Here we show using this newly developed AFM platform that the plasma membrane of live mammalian cells exhibits a constant and quantifiable nanomechanical property, the membrane elasticity. This mechanical property sensitively changes in response to environmental factors, such as the thermal, chemical, and growth factor stimuli. We demonstrate that different chemical inhibitors of endocytosis elicit distinct changes in plasma membrane elastic modulus reflecting their specific molecular actions on the lipid configuration or the endocytic machinery. Interestingly, two different growth factors, EGF and Wnt3a, elicited distinct elastic force profiles revealed by AFM at the plasma membrane during receptor-mediated endocytosis. By applying this platform to genetically modified cells, we uncovered a previously unknown contribution of Cdc42, a key component of the cellular trafficking network, to EGF-stimulated endocytosis at plasma membrane. Together, this nanomechanical AFM study establishes an important foundation that is expandable and adaptable for investigation of cellular membrane evolution in response to various key extracellular signals. © 2017 Wiley Periodicals, Inc.

  15. Enhancement of contractile force generation of artificial skeletal muscle tissues by mild and transient heat treatment.

    Science.gov (United States)

    Sato, Masanori; Ikeda, Kazushi; Kanno, Shota; Ito, Akira; Kawabe, Yoshinori; Kamihira, Masamichi

    2014-01-01

    Artificial skeletal muscle tissues composed of cells are expected to be used for applications of regenerative medicine and drug screening. Generally, however, the physical forces generated by tissue-engineered skeletal muscle are lower than those of skeletal muscle tissues found in the body. Local hyperthermia is used for many diseases including muscle injuries. It was recently reported that mild heat treatment improved skeletal muscle functions. In this study, we investigated the effects of mild heat treatment on the tissue-engineered skeletal muscle tissues in vitro. We used magnetite cationic liposomes to label C2C12 myoblast cells magnetically, and constructed densely packed artificial skeletal muscle tissues by using magnetic force. Cell culture at 39°C promoted the differentiation of myoblast cells into myotubes. Moreover, the mild and transient heat treatment improved the contractile properties of artificial skeletal muscle tissue constructs. These findings indicate that the culture method using heat treatment is a useful approach to enhance functions of artificial skeletal muscle tissue.

  16. Maximal isometric strength of the cervical musculature in 100 healthy volunteers

    DEFF Research Database (Denmark)

    Jordan, A; Mehlsen, J; Bülow, P M

    1999-01-01

    A descriptive study involving maximal isometric strength measurements of the cervical musculature.......A descriptive study involving maximal isometric strength measurements of the cervical musculature....

  17. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    Science.gov (United States)

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  18. Demonstration of Security Benefits of Renewable Generation at FE Warren Air Force Base

    International Nuclear Information System (INIS)

    Warwick, William M.; Myers, Kurt; Seifert, Gary

    2010-01-01

    Report detailing field demonstration of security benefits of renewable generation at FE Warren Air Force Base. The 2006 National Defense Appropriations Act directed the Department of Defense (DOD) to coordinate the testing of a wind turbine (new to the U.S. market) at an Air Force installation as a follow on to analyses conducted by the Pacific Northwest National Laborabory (PNNL) as part of the 2005 DOD Renewable Assessment. The earlier study simulated the performance of renewable power produced from wind turbines, solar photovoltaics and geothermal energy as part of a Base-wide energy security solution. The simulation concluded that integration of renewable generating resources with emergency generators, typically diesel-fired, could significantly enhance energy security and extend power supplies during prolonged commercial grid power outages. A simulation is insufficient to convince skeptics of the reliability of renewable resources, especially those that produce power only intermittently, like wind and solar. Therefore, Congress requested a field demonstration be performed using a wind turbine because wind power is the most erratic of all renewable resources. Following this direction, the Air Force identified a site for the wind turbine demonstration and contracted with the Idaho National Laboratory (INL) and PNNL to conduct the demonstration and implement other provisions in the appropriation bill. INL identified a wind turbine that met the legislative requirements (the Gamesa G-80), and with the support of PNNL and the Air Force, selected FE Warren Air Force Base for the demonstration. FE Warren has an excellent wind resource and was already a host to two wind turbines and could accommodate a third. The G-80 is rated at 2 MWs versus the two existing 660 kW turbines, consequently wind production would more than double. Procurement, siting, and acceptance testing of the new turbine was completed in early 2010. The field test was conducted in late April 2010

  19. Phase Aberration and Attenuation Effects on Acoustic Radiation Force-Based Shear Wave Generation.

    Science.gov (United States)

    Carrascal, Carolina Amador; Aristizabal, Sara; Greenleaf, James F; Urban, Matthew W

    2016-02-01

    Elasticity is measured by shear wave elasticity imaging (SWEI) methods using acoustic radiation force to create the shear waves. Phase aberration and tissue attenuation can hamper the generation of shear waves for in vivo applications. In this study, the effects of phase aberration and attenuation in ultrasound focusing for creating shear waves were explored. This includes the effects of phase shifts and amplitude attenuation on shear wave characteristics such as shear wave amplitude, shear wave speed, shear wave center frequency, and bandwidth. Two samples of swine belly tissue were used to create phase aberration and attenuation experimentally. To explore the phase aberration and attenuation effects individually, tissue experiments were complemented with ultrasound beam simulations using fast object-oriented C++ ultrasound simulator (FOCUS) and shear wave simulations using finite-element-model (FEM) analysis. The ultrasound frequency used to generate shear waves was varied from 3.0 to 4.5 MHz. Results: The measured acoustic pressure and resulting shear wave amplitude decreased approximately 40%-90% with the introduction of the tissue samples. Acoustic intensity and shear wave displacement were correlated for both tissue samples, and the resulting Pearson's correlation coefficients were 0.99 and 0.97. Analysis of shear wave generation with tissue samples (phase aberration and attenuation case), measured phase screen, (only phase aberration case), and FOCUS/FEM model (only attenuation case) showed that tissue attenuation affected the shear wave generation more than tissue aberration. Decreasing the ultrasound frequency helped maintain a focused beam for creation of shear waves in the presence of both phase aberration and attenuation.

  20. Unusual Wrist Tremor: Unilateral Isometric Tremor?

    Directory of Open Access Journals (Sweden)

    Theresa A. Zesiewicz

    2014-01-01

    Full Text Available Background: Tremors may be difficult to classify.Case Report: An 83‐year‐old male presented with an unusual left wrist tremor. The tremor could be reproducibly elicited by making a fist or carrying a weighted object (e.g., a shopping bag, bottle of water of approximately 1 lb or more, and it intensified with heavier weights. The tremor was difficult to classify, although it shared features with isometric tremor.Discussion: This specific presentation of tremor has not been reported previously. We hope that the detailed description we provide will aid other neurologists who encounter this or similar tremors in their clinics.

  1. Muscle force depends on the amount of transversal muscle loading.

    Science.gov (United States)

    Siebert, Tobias; Till, Olaf; Stutzig, Norman; Günther, Michael; Blickhan, Reinhard

    2014-06-03

    Skeletal muscles are embedded in an environment of other muscles, connective tissue, and bones, which may transfer transversal forces to the muscle tissue, thereby compressing it. In a recent study we demonstrated that transversal loading of a muscle with 1.3Ncm(-2) reduces maximum isometric force (Fim) and rate of force development by approximately 5% and 25%, respectively. The aim of the present study was to examine the influence of increasing transversal muscle loading on contraction dynamics. Therefore, we performed isometric experiments on rat M. gastrocnemius medialis (n=9) without and with five different transversal loads corresponding to increasing pressures of 1.3Ncm(-2) to 5.3Ncm(-2) at the contact area between muscle and load. Muscle loading was induced by a custom-made plunger which was able to move in transversal direction. Increasing transversal muscle loading resulted in an almost linear decrease in muscle force from 4.8±1.8% to 12.8±2% Fim. Compared to an unloaded isometric contraction, rate of force development decreased from 20.2±4.0% at 1.3Ncm(-2) muscle loading to 34.6±5.7% at 5.3Ncm(-2). Experimental observation of the impact of transversal muscle loading on contraction dynamics may help to better understand muscle tissue properties. Moreover, applying transversal loads to muscles opens a window to analyze three-dimensional muscle force generation. Data presented in this study may be important to develop and validate muscle models which enable simulation of muscle contractions under compression and enlighten the mechanisms behind. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Computational model to investigate the relative contributions of different neuromuscular properties of tibialis anterior on force generated during ankle dorsiflexion.

    Science.gov (United States)

    Siddiqi, Ariba; Poosapadi Arjunan, Sridhar; Kumar, Dinesh Kant

    2018-01-16

    This study describes a new model of the force generated by tibialis anterior muscle with three new features: single-fiber action potential, twitch force, and pennation angle. This model was used to investigate the relative effects and interaction of ten age-associated neuromuscular parameters. Regression analysis (significance level of 0.05) between the neuromuscular properties and corresponding simulated force produced at the footplate was performed. Standardized slope coefficients were computed to rank the effect of the parameters. The results show that reduction in the average firing rate is the reason for the sharp decline in the force and other factors, such as number of muscle fibers, specific force, pennation angle, and innervation ratio. The fast fiber ratio affects the simulated force through two significant interactions. This study has ranked the individual contributions of the neuromuscular factors to muscle strength decline of the TA and identified firing rate decline as the biggest cause followed by decrease in muscle fiber number and specific force. The strategy for strength preservation for the elderly should focus on improving firing rate. Graphical abstract Neuromuscular properties of Tibialis Anterior on force generated during ankle dorsiflexion.

  3. Pneumatic strength assessment device: design and isometric measurement.

    Science.gov (United States)

    Paulus, David C; Reiser, Raoul F; Troxell, Wade O

    2004-01-01

    In order to load a muscle optimally during resistance exercise, it should be heavily taxed throughout the entire range of motion for that exercise. However, traditional constant resistance squats only tax the lower-extremity muscles to their limits at the "sticking region" or a critical joint configuration of the exercise cycle. Therefore, a linear motion (Smith) exercise machine was modified with pneumatics and appropriate computer control so that it could be capable of adjusting force to control velocity within a repetition of the squat exercise or other exercise performed with the device. Prior to application of this device in a dynamic squat setting, the maximum voluntary isometric force (MVIF) produced over a spectrum of knee angles is needed. This would reveal the sticking region and overall variation in strength capacity. Five incremental knee angles (90, 110, 130, 150, and 170 degrees, where 180 degrees defined full extension) were examined. After obtaining university-approved informed consent, 12 men and 12 women participated in the study. The knee angle was set, and the pneumatic cylinder was pressurized such that the subject could move the barbell slightly but no more than two-centimeters. The peak pressure exerted over a five-second maximum effort interval was recorded at each knee angle in random order and then repeated. The average of both efforts was then utilized for further analysis. The sticking region occurred consistently at a 90 degrees knee angle, however, the maximum force produced varied between 110 degrees and 170 degrees with the greatest frequency at 150 degrees for both men and women. The percent difference between the maximum and minimum MVIF was 46% for men and 57% for women.

  4. The independent effects of speed and propulsive force on joint power generation in walking.

    Science.gov (United States)

    Browne, Michael G; Franz, Jason R

    2017-04-11

    Walking speed is modulated using propulsive forces (F P ) during push-off and both preferred speed and F P decrease with aging. However, even prior to walking slower, reduced F P may be accompanied by potentially unfavorable changes in joint power generation. For example, compared to young adults, older adults exhibit a redistribution of mechanical power generation from the propulsive plantarflexor muscles to more proximal muscles acting across the knee and hip. Here, we used visual biofeedback based on real-time F P measurements to decouple and investigate the interaction between joint-level coordination, whole-body F P , and walking speed. 12 healthy young subjects walked on a dual-belt instrumented treadmill at a range of speeds (0.9-1.3m/s). We immediately calculated the average F P from each speed. Subjects then walked at 1.3m/s while completing a series of biofeedback trials with instructions to match their instantaneous F P to their averaged F P from slower speeds. Walking slower decreased F P and total positive joint work with little effect on relative joint-level contributions. Conversely, subjects walked at a constant speed with reduced F P , not by reducing total positive joint work, but by redistributing the mechanical demands of each step from the plantarflexor muscles during push-off to more proximal leg muscles during single support. Interestingly, these naturally emergent joint- and limb-level biomechanical changes, in the absence of neuromuscular constraints, resemble those due to aging. Our findings provide important reference data to understand the presumably complex interactions between joint power generation, whole-body F P , and walking speed in our aging population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Visuomotor contribution to force variability in the plantarflexor and dorsiflexor muscles

    OpenAIRE

    Tracy, Brian L.

    2007-01-01

    The visual correction employed during isometric contractions of large proximal muscles contributes variability to the descending command and alters fluctuations in muscle force. This study explored the contribution of visuomotor correction to isometric force fluctuations for the more distal dorsiflexor (DF) and plantarflexor (PF) muscles of the ankle. Twenty-one healthy adults performed steady isometric contractions with the DF and PF muscles both with (VIS) and without (NOVIS) visual feedbac...

  6. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    Science.gov (United States)

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  7. An Adaptive Neuro-Fuzzy Inference System for Sea Level Prediction Considering Tide-Generating Forces and Oceanic Thermal Expansion

    Directory of Open Access Journals (Sweden)

    Li-Ching Lin Hsien-Kuo Chang

    2008-01-01

    Full Text Available The paper presents an adaptive neuro fuzzy inference system for predicting sea level considering tide-generating forces and oceanic thermal expansion assuming a model of sea level dependence on sea surface temperature. The proposed model named TGFT-FN (Tide-Generating Forces considering sea surface Temperature and Fuzzy Neuro-network system is applied to predict tides at five tide gauge sites located in Taiwan and has the root mean square of error of about 7.3 - 15.0 cm. The capability of TGFT-FN model is superior in sea level prediction than the previous TGF-NN model developed by Chang and Lin (2006 that considers the tide-generating forces only. The TGFT-FN model is employed to train and predict the sea level of Hua-Lien station, and is also appropriate for the same prediction at the tide gauge sites next to Hua-Lien station.

  8. Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes.

    Science.gov (United States)

    Huang, Peijian; Wang, Ning; Li, Junying; Zhu, Yong; Zhang, Jie

    2017-12-13

    Measuring the radial collision force between the steam generator tube (SGT) and the tube support plate (TSP) is essential to assess the fretting damage of the SGT. In order to measure the radial collision force, a novel miniaturized force sensor based on fiber Fabry-Perot (F-P) was designed, and the principle and characteristics of the sensor were analyzed in detail. Then, the F-P force sensor was successfully fabricated and calibrated, and the overall dimensions of the encapsulated fiber F-P sensor were 17 mm × 5 mm × 3 mm (L × W × H). The sensor works well in humid, high pressure (10 MPa), high temperature (350 °C), and vibration (40 kHz) environments. Finally, the F-P force sensors were installed in a 1:1 steam generator test loop, and the radial collision force signals between the SGT and the TSP were obtained. The experiments indicated that the F-P sensor with small volume and high performance could help in assessing the fretting damage of the steam generator tubes.

  9. Bioactive conformational generation of small molecules: A comparative analysis between force-field and multiple empirical criteria based methods

    Directory of Open Access Journals (Sweden)

    Jiang Hualiang

    2010-11-01

    Full Text Available Abstract Background Conformational sampling for small molecules plays an essential role in drug discovery research pipeline. Based on multi-objective evolution algorithm (MOEA, we have developed a conformational generation method called Cyndi in the previous study. In this work, in addition to Tripos force field in the previous version, Cyndi was updated by incorporation of MMFF94 force field to assess the conformational energy more rationally. With two force fields against a larger dataset of 742 bioactive conformations of small ligands extracted from PDB, a comparative analysis was performed between pure force field based method (FFBM and multiple empirical criteria based method (MECBM hybrided with different force fields. Results Our analysis reveals that incorporating multiple empirical rules can significantly improve the accuracy of conformational generation. MECBM, which takes both empirical and force field criteria as the objective functions, can reproduce about 54% (within 1Å RMSD of the bioactive conformations in the 742-molecule testset, much higher than that of pure force field method (FFBM, about 37%. On the other hand, MECBM achieved a more complete and efficient sampling of the conformational space because the average size of unique conformations ensemble per molecule is about 6 times larger than that of FFBM, while the time scale for conformational generation is nearly the same as FFBM. Furthermore, as a complementary comparison study between the methods with and without empirical biases, we also tested the performance of the three conformational generation methods in MacroModel in combination with different force fields. Compared with the methods in MacroModel, MECBM is more competitive in retrieving the bioactive conformations in light of accuracy but has much lower computational cost. Conclusions By incorporating different energy terms with several empirical criteria, the MECBM method can produce more reasonable conformational

  10. An Estimating Method of Contractile State Changes Come From Continuous Isometric Contraction of Skeletal Muscle

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.J.; Lee, S.J. [Wonkwang University, Iksan (Korea)

    2003-01-01

    In this study was proposed that a new estimating method for investigation of contractile state changes which generated from continuous isometric contraction of skeletal muscle. The physiological changes (EMG, ECG) and the psychological changes by CNS(central nervous system) were measured by experiments, while the muscle of subjects contracted continuously with isometric contraction in constant load. The psychological changes were represented as three-step-change named 'fatigue', 'pain' and 'sick(greatly pain)' from oral test, and the method which compared physiological change with psychological change on basis of these three steps was developed. The result of analyzing the physiological signals, EMG and ECG signal changes were observed at the vicinity of judging point in time of psychological changes. Namely, it is supposed that contractile states have three kind of states pattern (stable, fatigue, pain) instead of two states (stable, fatigue). (author). 24 refs., 7 figs.

  11. Reliability and fatigue characteristics of a standing hip isometric endurance protocol.

    Science.gov (United States)

    Mutchler, Jessica A; Weinhandl, Joshua T; Hoch, Matthew C; Van Lunen, Bonnie L

    2015-08-01

    Muscle fatigue is a common consideration when evaluating and rehabilitating athletic injuries. The presence of muscular fatigue has been previously determined by quantifying median frequency (MF) through a power spectral analysis on EMG signals collected throughout an endurance task. Research has not yet determined if a prolonged isometric test in a standing position generates muscular fatigue of the hip. The purpose of this study was to determine the reliability and fatigue characteristics of a standing hip isometric endurance test. Twenty healthy participants completed one 60-s Maximum Voluntary Isometric Contraction of standing hip flexion, extension, adduction, and abduction. MF of the participants' dominant limb rectus femoris (RF), biceps femoris (BF), gluteus maximus (GMax), gluteus medius (GMed) and adductor longus (ADD) was determined via surface electromyography during two sessions, 30-min apart. Reliability values (ICC2,1) were moderate-to-excellent for all time intervals of each action (FlexionRF: >0.80; ExtensionBF: >0.89; ExtensionGMax: >0.60; AdductionADD: >0.78; AbductionGMed: >0.60) and MF significantly decreased over time for all actions. Results suggest the endurance test is a reliable technique to generate muscular fatigue for hip flexion, extension, adduction and abduction. It can be used as a time efficient fatigue protocol specific to the RF, BF, GMax, ADD and GMed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Criterion and Construct Validity of an Isometric Midthigh-Pull Dynamometer for Assessing Whole-Body Strength in Professional Rugby League Players.

    Science.gov (United States)

    Dobbin, Nick; Hunwicks, Richard; Jones, Ben; Till, Kevin; Highton, Jamie; Twist, Craig

    2018-02-01

    To examine the criterion and construct validity of an isometric midthigh-pull dynamometer to assess whole-body strength in professional rugby league players. Fifty-six male rugby league players (33 senior and 23 youth players) performed 4 isometric midthigh-pull efforts (ie, 2 on the dynamometer and 2 on the force platform) in a randomized and counterbalanced order. Isometric peak force was underestimated (P  .05) between the predicted and peak force from the force platform and an adjusted R 2 (79.6%) that represented shrinkage of 0.4% relative to the cross-validation model (80%). Peak force was greater for the senior than the youth professionals using the dynamometer (2261.2 ± 222 cf 1725.1 ± 298.0 N, respectively; P isometric midthigh pull assessed using a dynamometer underestimates criterion peak force but is capable of distinguishing muscle-function characteristics between professional rugby league players of different standards.

  13. LITERATURE REVIEW OF ELECTROMAGNETIC ACTUATOR FORCE GENERATION FOR DYNAMIC MODAL TESTING APPLICATIONS

    Directory of Open Access Journals (Sweden)

    Norlida Jamil

    2012-12-01

    Full Text Available Milling is one of the most common manufacturing processes for automotive components, but its productivity is limited by the onset of regenerative chatter. This is a form of unstable self-excited vibration that occurs when the volume of material removed is too large for a particular spindle speed. This form of chatter is undesirable because it results in premature tool wear, poor surface finish on the machined component and the possibility of serious damage to the machine itself. The chatter stability of a milling process can be determined using well-established theory, provided that the frequency response of the flexible structure can be determined. In practice this usually involves the excitation of a stationery (non-rotating milling tool with a modal hammer, and measurement of the response of the tool with a co-located accelerometer. However, this measurement is not necessarily accurate due to amplitude dependency factor consideration. There is anecdotal evidence that structural nonlinearity can have a significant effect on the chatter stability of some milling machines. This project develops non-contact electromagnetic actuators to measure the frequency response of milling tools to machine automotive parts. In addition it will describe the practical application of this approach, and discuss its amplitude dependency for current excitation during frequency response function measurement using magnetic force generation.

  14. Characterization of the photocurrents generated by the laser of atomic force microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yanfeng; Hui, Fei; Shi, Yuanyuan; Lanza, Mario, E-mail: mlanza@suda.edu.cn [Institute of Functional Nano and Soft Materials (FUNSOM), Collaborative Innovation Center of Suzhou Nanoscience and Technology, Soochow University, 199 Ren-Ai Road, Suzhou 215123 (China); Iglesias, Vanessa [International Iberian Nanotechnology Laboratory, 4715-330 Braga (Portugal); Lewis, David [Nanonics Imaging, Har Hotzvim, Jerusalem 91487 (Israel); Niu, Jiebin; Long, Shibing; Liu, Ming [Laboratory of Nanofabrication and Novel Device Integration, Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China); Hofer, Alexander; Frammelsberger, Werner; Benstetter, Guenther [Deggendorf Institute of Technology, Edlmairstr. 6+8, 94469 Deggendorf (Germany); Scheuermann, Andrew; McIntyre, Paul C. [Department of Materials Science and Engineering, Stanford University, Stanford, California 94305 (United States)

    2016-08-15

    The conductive atomic force microscope (CAFM) has become an essential tool for the nanoscale electronic characterization of many materials and devices. When studying photoactive samples, the laser used by the CAFM to detect the deflection of the cantilever can generate photocurrents that perturb the current signals collected, leading to unreliable characterization. In metal-coated semiconductor samples, this problem is further aggravated, and large currents above the nanometer range can be observed even without the application of any bias. Here we present the first characterization of the photocurrents introduced by the laser of the CAFM, and we quantify the amount of light arriving to the surface of the sample. The mechanisms for current collection when placing the CAFM tip on metal-coated photoactive samples are also analyzed in-depth. Finally, we successfully avoided the laser-induced perturbations using a two pass technique: the first scan collects the topography (laser ON) and the second collects the current (laser OFF). We also demonstrate that CAFMs without a laser (using a tuning fork for detecting the deflection of the tip) do not have this problem.

  15. Directional migration of leading-edge mesoderm generates physical forces: Implication in Xenopus notochord formation during gastrulation.

    Science.gov (United States)

    Hara, Yusuke; Nagayama, Kazuaki; Yamamoto, Takamasa S; Matsumoto, Takeo; Suzuki, Makoto; Ueno, Naoto

    2013-10-15

    Gastrulation is a dynamic tissue-remodeling process occurring during early development and fundamental to the later organogenesis. It involves both chemical signals and physical factors. Although much is known about the molecular pathways involved, the roles of physical forces in regulating cellular behavior and tissue remodeling during gastrulation have just begun to be explored. Here, we characterized the force generated by the leading edge mesoderm (LEM) that migrates preceding axial mesoderm (AM), and investigated the contribution of LEM during Xenopus gastrulation. First, we constructed an assay system using micro-needle which could measure physical forces generated by the anterior migration of LEM, and estimated the absolute magnitude of the force to be 20-80nN. Second, laser ablation experiments showed that LEM could affect the force distribution in the AM (i.e. LEM adds stretch force on axial mesoderm along anterior-posterior axis). Third, migrating LEM was found to be necessary for the proper gastrulation cell movements and the establishment of organized notochord structure; a reduction of LEM migratory activity resulted in the disruption of mediolateral cell orientation and convergence in AM. Finally, we found that LEM migration cooperates with Wnt/PCP to form proper notochord. These results suggest that the force generated by the directional migration of LEM is transmitted to AM and assists the tissue organization of notochord in vivo independently of the regulation by Wnt/PCP. We propose that the LEM may have a mechanical role in aiding the AM elongation through the rearrangement of force distribution in the dorsal marginal zone. © 2013 Elsevier Inc. All rights reserved.

  16. Differential contributions of ankle plantarflexors during submaximal isometric muscle action

    DEFF Research Database (Denmark)

    Masood, Tahir; Bojsen-Møller, Jens; Kalliokoski, Kari K

    2014-01-01

    The objective of this study was to investigate the relative contributions of superficial and deep ankle plantarflexors during repetitive submaximal isometric contractions using surface electromyography (SEMG) and positron emission tomography (PET). Myoelectric signals were obtained from twelve...

  17. Isometric deformations of planar quadrilaterals with constant index

    International Nuclear Information System (INIS)

    Zaputryaeva, E S

    2014-01-01

    We consider isometric deformations (motions) of polygons (so-called carpenter's rule problem) in the case of self-intersecting polygons with the additional condition that the index of the polygon is preserved by the motion. We provide general information about isometric deformations of planar polygons and give a complete solution of the carpenter's problem for quadrilaterals. Bibliography: 17 titles

  18. Muscle spindle thixotropy affects force perception through afferent-induced facilitation of the motor pathways as revealed by the Kohnstamm effect.

    Science.gov (United States)

    Monjo, Florian; Forestier, Nicolas

    2018-04-01

    This study was designed to explore the effects of intrafusal thixotropy, a property affecting muscle spindle sensitivity, on the sense of force. For this purpose, psychophysical measurements of force perception were performed using an isometric force matching paradigm of elbow flexors consisting of matching different force magnitudes (5, 10 and 20% of subjects' maximal voluntary force). We investigated participants' capacity to match these forces after their indicator arm had undergone voluntary isometric conditioning contractions known to alter spindle thixotropy, i.e., contractions performed at long ('hold long') or short muscle lengths ('hold short'). In parallel, their reference arm was conditioned at the intermediate muscle length ('hold-test') at which the matchings were performed. The thixotropy hypothesis predicts that estimation errors should only be observed at low force levels (up to 10% of the maximal voluntary force) with overestimation of the forces produced following 'hold short' conditioning and underestimation following 'hold long' conditioning. We found the complete opposite, especially following 'hold-short' conditioning where subjects underestimated the force they generated with similar relative error magnitudes across force levels. In a second experiment, we tested the hypothesis that estimation errors depended on the degree of afferent-induced facilitation using the Kohnstamm phenomenon as a probe of motor pathway excitability. Because the stronger post-effects were observed following 'hold-short' conditioning, it appears that the conditioning-induced excitation of spindle afferents leads to force misjudgments by introducing a decoupling between the central effort and the cortical motor outputs.

  19. The relationship of motor unit size, firing rate and force.

    Science.gov (United States)

    Conwit, R A; Stashuk, D; Tracy, B; McHugh, M; Brown, W F; Metter, E J

    1999-07-01

    Using a clinical electromyographic (EMG) protocol, motor units were sampled from the quadriceps femoris during isometric contractions at fixed force levels to examine how average motor unit size and firing rate relate to force generation. Mean firing rates (mFRs) and sizes (mean surface-detected motor unit action potential (mS-MUAP) area) of samples of active motor units were assessed at various force levels in 79 subjects. MS-MUAP size increased linearly with increased force generation, while mFR remained relatively constant up to 30% of a maximal force and increased appreciably only at higher force levels. A relationship was found between muscle force and mS-MUAP area (r2 = 0.67), mFR (r2 = 0.38), and the product of mS-MUAP area and mFR (mS-MUAP x mFR) (r2 = 0.70). The results support the hypothesis that motor units are recruited in an orderly manner during forceful contractions, and that in large muscles only at higher levels of contraction ( > 30% MVC) do mFRs increase appreciably. MS-MUAP and mFR can be assessed using clinical EMG techniques and they may provide a physiological basis for analyzing the role of motor units during muscle force generation.

  20. Isokinetic and isometric muscle strength combined with transcutaneous electrical muscle stimulation in primary fibromyalgia syndrome

    DEFF Research Database (Denmark)

    Jacobsen, Søren; Wildschiødtz, Gordon; Danneskiold-Samsøe, B

    1991-01-01

    Twenty women with primary fibromyalgia syndrome and 20 age matched healthy women were investigated. The subjects performed maximum voluntary isokinetic contractions of the right quadriceps in an isokinetic dynamometer. Maximum voluntary isometric contractions of the right quadriceps were performed...... of superimposed twitches was 65% in the patient group and 15% in the control group (p = 0.003). Patients with primary fibromyalgia have a lower maximum voluntary muscle strength than expected. The increased presence of superimposed electrically elicited twitches during maximum voluntary contraction indicates...... submaximal force application in primary fibromyalgia syndrome....

  1. Integrated Analysis of Contractile Kinetics, Force Generation, and Electrical Activity in Single Human Stem Cell-Derived Cardiomyocytes

    Directory of Open Access Journals (Sweden)

    Jan David Kijlstra

    2015-12-01

    Full Text Available The quantitative analysis of cardiomyocyte function is essential for stem cell-based approaches for the in vitro study of human cardiac physiology and pathophysiology. We present a method to comprehensively assess the function of single human pluripotent stem cell-derived cardiomyocyte (hPSC-CMs through simultaneous quantitative analysis of contraction kinetics, force generation, and electrical activity. We demonstrate that statistical analysis of movies of contracting hPSC-CMs can be used to quantify changes in cellular morphology over time and compute contractile kinetics. Using a biomechanical model that incorporates substrate stiffness, we calculate cardiomyocyte force generation at single-cell resolution and validate this approach with conventional traction force microscopy. The addition of fluorescent calcium indicators or membrane potential dyes allows the simultaneous analysis of contractility and calcium handling or action potential morphology. Accordingly, our approach has the potential for broad application in the study of cardiac disease, drug discovery, and cardiotoxicity screening.

  2. Evaluation of the friction force generated by monocristalyne and policristalyne ceramic brackets in sliding mechanics

    Directory of Open Access Journals (Sweden)

    Roberta Ferreira Pimentel

    2013-02-01

    Full Text Available OBJECTIVE: To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu and one type of sapphire monocrystalline bracket (Radiance in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. METHODS: Tests were performed in dry and artificial saliva wet setting (Oral Balance by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in brackets (n = 18 for each bracket. In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. RESULTS: The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu, an increase of friction was observed in its presence. CONCLUSION: The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.OBJETIVO: avaliar e comparar in vitro as cargas máximas de atrito geradas por três tipos de braquetes estéticos, sendo dois deles cerâmicos policristalinos convencionais (20/40 e InVu e um monocristalino de safira (Radiance, em ambientes seco e umedecido por saliva artificial. Também avaliar a influência exercida pela saliva artificial sobre as cargas de atrito dos referidos

  3. Effects of in vivo-like activation frequency on the length-dependent force generation of skeletal muscle fibre bundles

    NARCIS (Netherlands)

    Zuurbier, C. J.; Lee-de Groot, M. B.; van der Laarse, W. J.; Huijing, P. A.

    1998-01-01

    It is known that a range of firing frequencies can be observed during in vivo muscle activity, yet information is lacking as to how different in vivo-like frequencies may affect force generation of skeletal muscle. This study examined the effects of constant (CSF, constant within one contraction)

  4. Generating a stationary infinite range tractor force via a multimode optical fibre

    Science.gov (United States)

    Ebongue, C. A.; Holzmann, D.; Ostermann, S.; Ritsch, H.

    2017-06-01

    Optical fibres confine and guide light almost unattenuated and thus convey light forces to polarizable nano-particles over very long distances. Radiation pressure forces arise from scattering of guided photons into free space while gradient forces are based on coherent scattering between different fibre modes or propagation directions. Interestingly, even scattering between co-propagating modes induces longitudinal forces as the transverse confinement of the light modes creates mode dependent longitudinal wave-vectors and photon momenta. We generalize a proven scattering matrix based approach to calculate single as well as inter-particle forces to include several forward and backward propagating modes. We show that an injection of the higher order mode only in a two mode fibre will induce a stationary tractor force against the injection direction, when the mode coupling to the lower order mode dominates against backscattering and free space losses. Generically this arises for non-absorbing particles at the centre of a waveguide. The model also gives improved predictions for inter-particle forces in evanescent nanofibre fields as experimentally observed recently. Surprisingly strong tractor forces can also act on whole optically bound arrays.

  5. Isometric exercise induces analgesia and reduces inhibition in patellar tendinopathy.

    Science.gov (United States)

    Rio, Ebonie; Kidgell, Dawson; Purdam, Craig; Gaida, Jamie; Moseley, G Lorimer; Pearce, Alan J; Cook, Jill

    2015-10-01

    Few interventions reduce patellar tendinopathy (PT) pain in the short term. Eccentric exercises are painful and have limited effectiveness during the competitive season. Isometric and isotonic muscle contractions may have an immediate effect on PT pain. This single-blinded, randomised cross-over study compared immediate and 45 min effects following a bout of isometric and isotonic muscle contractions. Outcome measures were PT pain during the single-leg decline squat (SLDS, 0-10), quadriceps strength on maximal voluntary isometric contraction (MVIC), and measures of corticospinal excitability and inhibition. Data were analysed using a split-plot in time-repeated measures analysis of variance (ANOVA). 6 volleyball players with PT participated. Condition effects were detected with greater pain relief immediately from isometric contractions: isometric contractions reduced SLDS (mean±SD) from 7.0±2.04 to 0.17±0.41, and isotonic contractions reduced SLDS (mean±SD) from 6.33±2.80 to 3.75±3.28 (peffect on inhibition (pre 30.26±3.89, post 31.92±4.67; p=0.004). Condition by time analysis showed pain reduction was sustained at 45 min postisometric but not isotonic condition (ptendon pain immediately for at least 45 min postintervention and increased MVIC. The reduction in pain was paralleled by a reduction in cortical inhibition, providing insight into potential mechanisms. Isometric contractions can be completed without pain for people with PT. The clinical implications are that isometric muscle contractions may be used to reduce pain in people with PT without a reduction in muscle strength. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Forearm muscle oxygenation during sustained isometric contractions in rock climbers

    Directory of Open Access Journals (Sweden)

    Jan Kodejška

    2016-02-01

    Full Text Available Background. Bouldering and lead climbing are divergent disciplines of the sport of rock climbing. Bouldering moves are short and powerful, whilst sport climbing is longer and require a greater degree of endurance. Aim. The aim of this study was to compare forearm muscle oxygenation during sustained isometric contraction between lead climbers (LC and boulderers (BO. Methods. Eight BO and twelve LC completed maximal finger flexor strength test and sustained contractions to exhaustion at 60% of maximum voluntary contraction (MVC. Differences between BO and LC in maximal strength, time to exhaustion, force time integral (FTI, and tissue oxygenation (SmO2 were assessed by t-test for independent samples. Results. LC showed significantly lower level of average tissue oxygenation (BO 38.9% SmO2, s = 7.4; LC 28.7% SmO2, s = 7.1 and maximal tissue deoxygenation (BO 25.6% SmO2, s = 8.2; LC 13.5% SmO2, s = 8.5. LC demonstrated significantly lower finger flexor strength (519 N, s = 72 than BO (621 N, s = 142. LC sustained a longer time of contraction (not significantly (BO 52.2 s, s = 11.5; LC 60.6 s, s = 13 and achieved a similar value of FTI (BO 17421 Ns, s = 4291; LO 17476 Ns, s = 5036 in the endurance test. Conclusions. The results showed lower deoxygenation during sustained contraction in BO than LC despite similar FTI, indicating different local metabolic pathways in both groups.

  7. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    Science.gov (United States)

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  8. Supply Chain Management as a Driving Force for Generating Competitive Advantage for Dairy Companies

    Directory of Open Access Journals (Sweden)

    Irina Olegovna Poleshkina

    2016-11-01

    Full Text Available The study aims to uncover the reserves to generate competitive advantages for the participants of the market of perishables in the case of the dairy sector due to the formation of effective supply chains, as this category of goods is the most demanding in terms of periods and conditions of transportation and terms of preservation. The research technique is based on the concepts of value chains and supply chain management. In order to optimize the distribution of functions between the participants of the dairy chain a process-based approach has been applied. The research has revealed the main reasons for high aggregate costs and the places of their formation at each stage of the dairy supply chain. The article proposes the mechanisms to address three main problems arising from the process of building relations between the participants of the dairy supply chain in Russia. These problems are associated with a disproportionate margin distribution between the participants of the chain, with non-compliance of the quality of raw milk with the requirements for the production of specific types of dairy products, and with distrust of the supply chain participants, which increases transaction costs and forces to create reserve supplies which reduce the competitiveness of the whole dairy supply chain in general. In order to improve the competitiveness of all participants in the dairy chain, the article presents several mechanisms for solving these problems. The first is margin distribution based on the costs incurred by each participant of the dairy chain. The second is the use of a mathematical model to determine the assortment of goods of a dairy enterprise on the basis of the incoming volume and quality of raw milk according to the seasonal factor and the demand for dairy products. The third is the feasibility of refusal from the formation of reserve supplies by all participants of the dairy chain, which will not only minimize aggregate costs, but also

  9. Analysis of optimal Reynolds number for developing laminar forced convection in double sine ducts based on entropy generation minimization principle

    International Nuclear Information System (INIS)

    Ko, T.H.

    2006-01-01

    In the present paper, the entropy generation and optimal Reynolds number for developing forced convection in a double sine duct with various wall heat fluxes, which frequently occurs in plate heat exchangers, are studied based on the entropy generation minimization principle by analytical thermodynamic analysis as well as numerical investigation. According to the thermodynamic analysis, a very simple expression for the optimal Reynolds number for the double sine duct as a function of mass flow rate, wall heat flux, working fluid and geometric dimensions is proposed. In the numerical simulations, the investigated Reynolds number (Re) covers the range from 86 to 2000 and the wall heat flux (q'') varies as 160, 320 and 640 W/m 2 . From the numerical simulation of the developing laminar forced convection in the double sine duct, the effect of Reynolds number on entropy generation in the duct has been examined, through which the optimal Reynolds number with minimal entropy generation is detected. The optimal Reynolds number obtained from the analytical thermodynamic analysis is compared with the one from the numerical solutions and is verified to have a similar magnitude of entropy generation as the minimal entropy generation predicted by the numerical simulations. The optimal analysis provided in the present paper gives worthy information for heat exchanger design, since the thermal system could have the least irreversibility and best exergy utilization if the optimal Re can be used according to practical design conditions

  10. A standing pressure wave hypothesis of oscillating forces generated during a steam line break

    International Nuclear Information System (INIS)

    Tinoco, H.

    2001-01-01

    A rapid glance at the figure depicting the net forces acting on the reactor vessel and internals, as obtained through a CFD simulation of a BWR steam line break, reveals an amazing oscillating regularity of these forces which is in glaring contrast to the chaotic behaviour of the steam pressure field in the steam annulus. Assuming that the decompression process excites and maintains standing pressure waves in the annular cylindrical region constituted by the steam annulus, it is possible to reconstruct the net forces acting on the reactor vessel and internals through the contribution of almost only the first dispersive mode. If a Neumann boundary condition is assumed at the section connecting the steam annulus to the steam dome, the frequency predicted is approximately % 5.9 higher than that of the CFD simulations. However, this connecting section allows wave transmission, and a more appropriate boundary condition should be one of the Robin type. Therefore, this section is modelled as an absorbing wall, and the corresponding normal impedance is calculated using the CFD simulations. Week non-linear effects can also be observed in the calculated forces through the presence of the first subharmonic. By the methodology described above, an estimate of the forces acting on the reactor vessel and internals of unit 3 of Forsmark Nuclear Power Plant has been obtained. (author)

  11. Meeting the challenges of the new energy industry: The driving forces facing electric power generators and the natural gas industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The proceedings of the IGT national conference on meeting the challenges of the New Energy Industry: The driving forces facing Electric Power Generators and the Natural Gas Industry are presented. The conference was held June 19-21, 1995 at the Ambassador West Hotel in Downtown Chicago, Illinois. A separate abstract and indexing for each of the 18 papers presented for inclusion in the Energy Science and Technology Database.

  12. Meeting the challenges of the new energy industry: The driving forces facing electric power generators and the natural gas industry

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The proceedings of the IGT national conference on meeting the challenges of the New Energy Industry: The driving forces facing Electric Power Generators and the Natural Gas Industry are presented. The conference was held June 19-21, 1995 at the Ambassador West Hotel in Downtown Chicago, Illinois. A separate abstract and indexing for each of the 18 papers presented for inclusion in the Energy Science and Technology Database

  13. Using PHM to measure equipment usable life on the Air Force's next generation reusable space booster

    Science.gov (United States)

    Blasdel, A.

    The U.S. Air Force procures many launch vehicles and launch vehicle services to place their satellites at their desired location in space. The equipment on-board these satellite and launch vehicle often suffer from premature failures that result in the total loss of the satellite or a shortened mission life sometimes requiring the purchase of a replacement satellite and launch vehicle. The Air Force uses its EELV to launch its high priority satellites. Due to a rise in the cost of purchasing a launch using the Air Force's EELV from 72M in 1997 to as high as 475M per launch today, the Air Force is working to replace the EELV with a reusable space booster (RSB). The RSB will be similar in design and operations to the recently cancelled NASA reusable space booster known as the Space Shuttle. If the Air Force uses the same process that procures the EELV and other launch vehicles and satellites, the RSB will also suffer from premature equipment failures thus putting the payloads at a similar high risk of mission failure. The RSB is expected to lower each launch cost by 50% compared to the EELV. The development of the RSB offers the Air Force an opportunity to use a new reliability paradigm that includes a prognostic and health management program and a condition-based maintenance program. These both require using intelligent, decision making self-prognostic equipment The prognostic and health management program and its condition-based maintenance program allows increases in RSB equipment usable life, lower logistics and maintenance costs, while increasing safety and mission assurance. The PHM removes many decisions from personnel that, in the past resulted in catastrophic failures and loss of life. Adding intelligent, decision-making self-prognostic equipment to the RSB will further decrease launch costs while decreasing risk and increasing safety and mission assurance.

  14. Magnetic Circuit Model of PM Motor-Generator to Predict Radial Forces

    Science.gov (United States)

    McLallin, Kerry (Technical Monitor); Kascak, Peter E.; Dever, Timothy P.; Jansen, Ralph H.

    2004-01-01

    A magnetic circuit model is developed for a PM motor for flywheel applications. A sample motor is designed and modeled. Motor configuration and selection of materials is discussed, and the choice of winding configuration is described. A magnetic circuit model is described, which includes the stator back iron, rotor yoke, permanent magnets, air gaps and the stator teeth. Iterative solution of this model yields flux linkages, back EMF, torque, power, and radial force at the rotor caused by eccentricity. Calculated radial forces are then used to determine motor negative stiffness.

  15. INFLUENCE OF STRENGTH TRAINING PROGRAM ON ISOMETRIC MUSCLE STRENGTH IN YOUNG ATHLETES

    Directory of Open Access Journals (Sweden)

    Dragan Radovanovic

    2007-10-01

    Full Text Available Strength training, or resistance training, is a form of physical conditioning used to increase the ability to resist force. Since muscular strength is required for success in many sports, it is logical to assume that stronger and more powerful young athletes will achieve better results. The aim of the study was to examine the effects of strength training on young athletes. An eight-week strength training program for developing muscle strength was performed in this study. Training protocol was designed specifically for young adolescent’s athletes. The program consisted of exercises for lower and upper body, abdominal and lower back muscles. The programs did not involve the maximal (1-3 repetitions maximum and other very hard intensity exercises that may had negative effect on young athletes. The results showed that strength training program had positive effects on maximal isometric muscle force (Fmax and motor skill. The increase presents the combined influence of strength training and growth.

  16. Improving nuclear utility generation capacity, understanding the sources of forced outage and learning how to prevent them

    International Nuclear Information System (INIS)

    Brodeur, D.L.; Todreas, N.E.; Angus, V.T.

    1998-01-01

    MIT and PECO Energy have completed a detailed examination of the sources of forced outages at the Limerick Generating Station (LGS) Boiling Water Reactor Class IV (BWR IV) site over a five year period and contrasted that information to similar BWR IV utilities in the United States over the same period. Each forced outage was attributed to one system and assigned causal codes of equipment versus human factors and failure attributes such as weak design, poor craftsmanship, and worn parts. It was found that fifty four percent of the lost power at LGS was the result of Balance of Plant failures. Industry wide data identifies fifty nine percent of the lost power as attributed to Balance of Plant failures. Balance of Plant systems are those systems not included in the primary and safety related system category. Considering failure causal factors, forty six percent of the lost power at the utility under study was the result of equipment factors such as weak design or worn parts. Significantly, the study showed a high variance between those systems which caused significant forced outage at the two sister LGS units. This demonstrated the infrequent nature of plant forced outages within a given system. This was supported by the observation that dominant systems attributing to forced outage at LGS were not equally represented in industry data. It is suggested that for individual utilities to dramatically improve unit capability factors with regard to Balance of Plant systems, they must learn from industry wide experiences and develop cooperative means of exchanging lessons learned among similarly designed plants and systems. With the broad knowledge base of system failures, current designs must be frequently assessed and altered until each system poses an acceptable level of risk to generation capacity. (author)

  17. Use of a magnetic force exciter to vibrate a piezocomposite generating element in a small-scale windmill

    International Nuclear Information System (INIS)

    Luong, Hung Truyen; Goo, Nam Seo

    2012-01-01

    A piezocomposite generating element (PCGE) can be used to convert ambient vibrations into electrical energy that can be stored and used to power other devices. This paper introduces a design of a magnetic force exciter for a small-scale windmill that vibrates a PCGE to convert wind energy into electrical energy. A small-scale windmill was designed to be sensitive to low-speed wind in urban regions for the purpose of collecting wind energy. The magnetic force exciter consists of exciting magnets attached to the device’s input rotor and a secondary magnet fixed at the tip of the PCGE. The PCGE is fixed to a clamp that can be adjusted to slide on the windmill’s frame in order to change the gap between exciting and secondary magnets. Under an applied wind force, the input rotor rotates to create a magnetic force interaction that excites the PCGE. The deformation of the PCGE enables it to generate electric power. Experiments were performed with different numbers of exciting magnets and different gaps between the exciting and secondary magnets to determine the optimal configuration for generating the peak voltage and harvesting the maximum wind energy for the same range of wind speeds. In a battery-charging test, the charging time for a 40 mA h battery was approximately 3 h for natural wind in an urban region. The experimental results show that the prototype can harvest energy in urban regions with low wind speeds and convert the wasted wind energy into electricity for city use. (paper)

  18. ATK-ForceField: a new generation molecular dynamics software package

    Science.gov (United States)

    Schneider, Julian; Hamaekers, Jan; Chill, Samuel T.; Smidstrup, Søren; Bulin, Johannes; Thesen, Ralph; Blom, Anders; Stokbro, Kurt

    2017-12-01

    ATK-ForceField is a software package for atomistic simulations using classical interatomic potentials. It is implemented as a part of the Atomistix ToolKit (ATK), which is a Python programming environment that makes it easy to create and analyze both standard and highly customized simulations. This paper will focus on the atomic interaction potentials, molecular dynamics, and geometry optimization features of the software, however, many more advanced modeling features are available. The implementation details of these algorithms and their computational performance will be shown. We present three illustrative examples of the types of calculations that are possible with ATK-ForceField: modeling thermal transport properties in a silicon germanium crystal, vapor deposition of selenium molecules on a selenium surface, and a simulation of creep in a copper polycrystal.

  19. Lonely Skies: Air-to-Air Training for a 5th Generation Fighter Force

    Science.gov (United States)

    2015-06-01

    factsheet.asp?id=4353; Anthony M. Thornborough, The Phantom Story (London ; New York: Arms and Armour  : Distributed in the USA by Sterling Pub. Co, 1994...trained extensively to become expert replicators. The lack of formal training reduced the fidelity of replication that in- house adversaries could...conduct sustained operations. A loss of air superiority also jeopardizes the Air Force’s ability to project power or protect US and coalition forces

  20. Wall Climbing Robot Using Electrostatic Adhesion Force Generated by Flexible Interdigital Electrodes

    Directory of Open Access Journals (Sweden)

    Rong Liu

    2013-01-01

    Full Text Available Electrostatic adhesion technology has broad application prospects on wall climbing robots because of its unique characteristics compared with other types of adhesion technologies. A double tracked wall climbing robot based on electrostatic adhesion technology is presented including electrode panel design, mechanical structure design, power supply system design and control system design. A theoretical adhesion model was established and the electrostatic potential and field were expressed by series expansions in terms of solutions of the Laplace function. Based on this model, the electrostatic adhesion force was calculated using the Maxwell stress tensor formulation. Several important factors which may influence the electrostatic adhesion force were analysed and discussed by both FEM simulation and theoretical calculation. In addition, experiments on the adhesion performance of the electrode panel and the climbing performance of the robot on various wall materials were carried out. Both the simulation and experiment results verify the feasibility of electrostatic adhesion technology being applied on wall climbing robots. The theoretical model and calculation method for the electrostatic adhesion force proposed in this paper are also justified.

  1. Isometric immersions and embeddings of locally Euclidean metrics in R2

    International Nuclear Information System (INIS)

    Sabitov, I Kh

    1999-01-01

    This paper deals with the problem of isometric immersions and embeddings of two-dimensional locally Euclidean metrics in the Euclidean plane. We find explicit formulae for the immersions of metrics defined on a simply connected domain and a number of sufficient conditions for the existence of isometric embeddings. In the case when the domain is multiply connected we find necessary conditions for the existence of isometric immersions and classify the cases when the metric admits no isometric immersion in the Euclidean plane

  2. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  3. The Representation of Isometric Operators on C(1)(X)

    International Nuclear Information System (INIS)

    Li Jingke

    2010-01-01

    In this paper,we introduce a new norm on C (1) (X), which is induced by a hexagon on R 2 , and prove that every isometric operator on C (1) (X) can be induced by a homeomorphism of X, where X is a connected subset of R.

  4. Entropy Generation Analysis and Performance Evaluation of Turbulent Forced Convective Heat Transfer to Nanofluids

    Directory of Open Access Journals (Sweden)

    Yu Ji

    2017-03-01

    Full Text Available The entropy generation analysis of fully turbulent convective heat transfer to nanofluids in a circular tube is investigated numerically using the Reynolds Averaged Navier–Stokes (RANS model. The nanofluids with particle concentration of 0%, 1%, 2%, 4% and 6% are treated as single phases of effective properties. The uniform heat flux is enforced at the tube wall. To confirm the validity of the numerical approach, the results have been compared with empirical correlations and analytical formula. The self-similarity profiles of local entropy generation are also studied, in which the peak values of entropy generation by direct dissipation, turbulent dissipation, mean temperature gradients and fluctuating temperature gradients for different Reynolds number as well as different particle concentration are observed. In addition, the effects of Reynolds number, volume fraction of nanoparticles and heat flux on total entropy generation and Bejan number are discussed. In the results, the intersection points of total entropy generation for water and four nanofluids are observed, when the entropy generation decrease before the intersection and increase after the intersection as the particle concentration increases. Finally, by definition of Ep, which combines the first law and second law of thermodynamics and attributed to evaluate the real performance of heat transfer processes, the optimal Reynolds number Reop corresponding to the best performance and the advisable Reynolds number Read providing the appropriate Reynolds number range for nanofluids in convective heat transfer can be determined.

  5. EFFECT OF ISOMETRIC QUADRICEPS STRENGTHENING EXERCISE AT MULTIPLE ANGLES IN KNEE JOINT AMONG NORMAL ADULTS

    Directory of Open Access Journals (Sweden)

    JibiPaul

    2014-04-01

    Full Text Available Introduction: Strengthening exercises have been routinely used in persons with orthopaedic problems and athletes to increase force production or minimize muscle imbalance and joint injuries.Many studies have reported that isometric contractions can rapidly increases strength in quadriceps muscle. Objective: Objective of the study was to find out the effect of isometric strengthening exercise on strength of quadriceps at 45 and 90 degree of knee joint and also to compare the effect of strengthening exercise on strength of quadriceps at multiple angles of knee joint among control and experimental group. Methodology: This was a ccomparative experimental study with forty female healthy subjects from physiotherapy department of KPJ Healthcare University College, Malaysia. Convenient sampling method used to select the samples. The subjects were selected by inclusion criteria and randomly divided equally in to two with 20 subjects in each group. Isometric strengthening exercise and squatting exercise were given as intervention program for eight weeks respectively for experimental and control group. Pre and post data of quadriceps muscle strength measured were collected separately at 45 and 90 degree of knee joint using goniometry during resisted extension of knee in multi gym. Result: In experimental group Pre –Post statistical analysis found significant effect in increase of quadriceps strength at 45 and 90 degree with P<0.0001.****In control group quadriceps pre-post statistical analysis found no significant effect in increase of quadriceps strength at 45 and 90 degree with P<0.083NS and P<0.055 NS respectively. Comparative study between experimental and control groups for quadriceps strength at 90 degree of knee joint found significant effect in increase of quadriceps strength with P< 0.001.*** Comparative study between experimental and control groups for quadriceps strength at 45 degree of knee joint found significant effect in increase of

  6. Force generation due to three-dimensional plasma discharge on a conical forebody using pulsed direct current actuators

    International Nuclear Information System (INIS)

    Singh, Kunwar Pal; Roy, Subrata

    2008-01-01

    Understanding the behavior of three-dimensional plasmas around a pulsed dc actuator can be useful for its efficient operation in many applications. The effect of such actuators is studied using a self-consistent multibody system of neutral oxygen species and its plasma. The equations governing the motion of charged species are solved with the drift diffusion approximation. The electrostatic potential is computed from Poisson's equation. The electric field and ionization level are the highest close to the junction of electrodes and dielectric. The plasma body force thus generated also follows a similar characteristic. Results also show some dc corona instabilities. The temporal average of such force shows mostly acceleration from anode to cathode above the actuator

  7. Discharge properties of motor units during steady isometric contractions performed with the dorsiflexor muscles.

    Science.gov (United States)

    Jesunathadas, Mark; Klass, Malgorzata; Duchateau, Jacques; Enoka, Roger M

    2012-06-01

    The purpose of this study was to record the discharge characteristics of tibialis anterior motor units over a range of target forces and to import these data, along with previously reported observations, into a computational model to compare experimental and simulated measures of torque variability during isometric contractions with the dorsiflexor muscles. The discharge characteristics of 44 motor units were quantified during brief isometric contractions at torques that ranged from recruitment threshold to an average of 22 ± 14.4% maximal voluntary contraction (MVC) torque above recruitment threshold. The minimal [range: 5.8-19.8 pulses per second (pps)] and peak (range: 8.6-37.5 pps) discharge rates of motor units were positively related to the recruitment threshold torque (R(2) ≥ 0.266; P recruitment was positively associated with recruitment threshold torque (R(2) = 0.443; P recruitment threshold torque. The variability in the simulated torque did not differ from the experimental values once the recruitment range was set to ∼85% MVC torque, and the association between motor twitch contraction times and peak twitch torque was defined as a weak linear association (R(2) = 0.096; P motor units in the tibialis anterior.

  8. Isometric muscle fatigue of the paravertebral and upper extremity muscles after whiplash injury.

    Science.gov (United States)

    Rastovic, Pejana; Gojanovic, Marija Definis; Berberovic, Marina; Pavlovic, Marko; Lesko, Josip; Galic, Gordan; Pandza, Maja

    2017-01-01

    Whiplash-associated disorders (WAD) result from injury of neck structures that most often occur during traffic accidents as a result of rapid acceleration-deceleration. The dominant symptoms manifest in the musculoskeletal system and include increased fatigue. Because of the frequency of whiplash injuries, a simple, cheap and useful diagnostic tool is needed to differentiate whiplash injury from healthy patients or those faking symptoms. To determine muscle fatigue in patients with whiplash injury in six body positions. Analytical cross-sectional study. Emergency center, university hospital. We studied patients with whiplash injury from vehicular traffic accidents who presented to the emergency center within 6 hours of sustaining the injury. We determined whiplash injury grade according to the Quebec Task Force (QTF) classification and measured isometric muscle endurance in six different body positions. Control subjects for each patient were matched by age, gender and anthropomorphic characteristics. Cut-off values were determined to distinguish patients with whiplash injury from controls and for determination of injury grade . QTF grade, time to muscle fatigue in seconds. From September 2013 to September 2016, we enrolled 75 patients with whiplash injury and 75 matching control subjects. In all six positions, the patients with whiplash injury felt muscle fatigue faster than equivalent controls (P whiplash injury grade in all six positions (P whiplash injury and grade. The size of the sample was small. An objective parameter such as electromyography is needed to confirm isometric muscle fatigue.

  9. Bed rest attenuates sympathetic and pressor responses to isometric exercise in antigravity leg muscles in humans.

    Science.gov (United States)

    Kamiya, Atsunori; Michikami, Daisaku; Shiozawa, Tomoki; Iwase, Satoshi; Hayano, Junichiro; Kawada, Toru; Sunagawa, Kenji; Mano, Tadaaki

    2004-05-01

    Although spaceflight and bed rest are known to cause muscular atrophy in the antigravity muscles of the legs, the changes in sympathetic and cardiovascular responses to exercises using the atrophied muscles remain unknown. We hypothesized that bed rest would augment sympathetic responses to isometric exercise using antigravity leg muscles in humans. Ten healthy male volunteers were subjected to 14-day 6 degrees head-down bed rest. Before and after bed rest, they performed isometric exercises using leg (plantar flexion) and forearm (handgrip) muscles, followed by 2-min postexercise muscle ischemia (PEMI) that continues to stimulate the muscle metaboreflex. These exercises were sustained to fatigue. We measured muscle sympathetic nerve activity (MSNA) in the contralateral resting leg by microneurography. In both pre- and post-bed-rest exercise tests, exercise intensities were set at 30 and 70% of the maximum voluntary force measured before bed rest. Bed rest attenuated the increase in MSNA in response to fatiguing plantar flexion by approximately 70% at both exercise intensities (both P antigravity leg muscles.

  10. Discharge characteristics of biceps brachii motor units at recruitment when older adults sustained an isometric contraction.

    Science.gov (United States)

    Pascoe, Michael A; Holmes, Matthew R; Enoka, Roger M

    2011-02-01

    The purpose of this study was to compare the discharge characteristics of motor units recruited during an isometric contraction that was sustained with the elbow flexor muscles by older adults at target forces that were less than the recruitment threshold force of each isolated motor unit. The discharge times of 27 single motor units were recorded from the biceps brachii in 11 old adults (78.8 ± 5.9 yr). The target force was set at either a relatively small (6.6 ± 3.7% maximum) or large (11.4 ± 4.5% maximum) difference below the recruitment threshold force and the contraction was sustained until the motor unit was recruited and discharged action potentials for about 60 s. The time to recruitment was longer for the large target-force difference (P = 0.001). At recruitment, the motor units discharged repetitively for both target-force differences, which contrasts with data from young adults when motor units discharged intermittently at recruitment for the large difference between recruitment threshold force and target force. The coefficient of variation (CV) for the first five interspike intervals (ISIs) increased from the small (18.7 ± 7.9) to large difference (35.0 ± 10.2%, P = 0.008) for the young adults, but did not differ for the two target force differences for the old adults (26.3 ± 14.7 to 24.0 ± 13.1%, P = 0.610). When analyzed across the discharge duration, the average CV for the ISI decreased similarly for the two target-force differences (P = 0.618) in old adults. These findings contrast with those of young adults and indicate that the integration of synaptic input during sustained contractions differs between young and old adults.

  11. Piezo-generated charge mapping revealed through direct piezoelectric force microscopy.

    Science.gov (United States)

    Gomez, A; Gich, M; Carretero-Genevrier, A; Puig, T; Obradors, X

    2017-10-24

    While piezoelectric and ferroelectric materials play a key role in many everyday applications, there are still a number of open questions related to their physics. To enhance our understanding of piezoelectrics and ferroelectrics, nanoscale characterization is essential. Here, we develop an atomic force microscopy based mode that obtains a direct quantitative analysis of the piezoelectric coefficient d 33 . We report nanoscale images of piezogenerated charge in a thick single crystal of periodically poled lithium niobate (PPLN), a bismuth ferrite (BiFO 3 ) thin film, and lead zirconate titanate (PZT) by applying a force and recording the current produced by these materials. The quantification of d 33 coefficients for PPLN (14 ± 3 pC per N) and BFO (43 ± 6 pC per N) is in agreement with the values reported in the literature. Even stronger evidence of the reliability of the method is provided by an equally accurate measurement of the significantly larger d 33 of PZT.

  12. Effectiveness of Side Force Models for Flow Simulations Downstream of Vortex Generators

    NARCIS (Netherlands)

    Florentie, L.; van Zuijlen, A.H.; Hulshoff, S.J.; Bijl, H.

    2017-01-01

    Vortex generators (VGs) are a widely used means of flow control, and predictions of their influence are vital for efficient designs. However, accurate CFD simulations of their effect on the flow field by means of a body fitted mesh are computationally expensive. Therefore the BAY and jBAY models,

  13. Energy price spread as a driving force for combined generation investments: A view on Europe

    International Nuclear Information System (INIS)

    Kavvadias, K.C.

    2016-01-01

    Combined generation of heat, cooling and power has a large potential to increase its share in distributed generation of energy. Such investments are driven by energy savings which result to operational profits. These profits are very sensitive to the prices of the competitive energy products: electricity and gas. In this work a theoretical indicator is developed between energy prices, the technical characteristics of cogeneration and conventional generation equipment and the investment viability. Through this indicator, the operational profitability of cogeneration equipment is mapped and discussed. Empirical rules are extracted which can give a clear view of the sensitivity of energy prices on energy efficiency investments. The European cogeneration status quo is analyzed in terms of energy prices and market share. The developed indicator is also used, to analyze market related barriers and highlight the importance of energy pricing policy as a tool to minimize the risk exposure of energy efficiency investments. - Highlights: • Energy price spread of competitive fuels affects combined generation profitability. • Its uncertainty is the most important barrier for new investments. • The minimum energy price spread had been generalized and mathematically justified. • Can be used as a tax-based mechanism to hedge the risk of fuel price fluctuations. • For a typical installation, power has to be at least 2 times more expensive than gas.

  14. Effect of Hemipelvectomy Amputation on Kinematics and Muscle Force Generation of Lower Limb While Walking

    Directory of Open Access Journals (Sweden)

    Keyvan Sharifmoradi

    2017-07-01

    Conclusion The kinematics pattern of the patient’s lower limb during gait is different. Kinematic changes are associated with a significant increase in lower limb muscle generation that can have a degenerative effect on the knee joint. So the importance of this subject should be considered by rehabilitation experts.

  15. Force generation and temperature-jump and length-jump tension transients in muscle fibers.

    Science.gov (United States)

    Davis, J S; Rodgers, M E

    1995-01-01

    Muscle tension rises with increasing temperature. The kinetics that govern the tension rise of maximally Ca(2+)-activated, skinned rabbit psoas fibers over a temperature range of 0-30 degrees C was characterized in laser temperature-jump experiments. The kinetic response is simple and can be readily interpreted in terms of a basic three-step mechanism of contraction, which includes a temperature-sensitive rapid preequilibrium(a) linked to a temperature-insensitive rate-limiting step and followed by a temperature-sensitive tension-generating step. These data and mechanism are compared and contrasted with the more complex length-jump Huxley-Simmons phases in which all states that generate tension or bear tension are perturbed. The rate of the Huxley-Simmons phase 4 is temperature sensitive at low temperatures but plateaus at high temperatures, indicating a change in rate-limiting step from a temperature-sensitive (phase 4a) to a temperature-insensitive reaction (phase 4b); the latter appears to correlate with the slow, temperature-insensitive temperature-jump relaxation. Phase 3 is absent in the temperature-jump, which excludes it from tension generation. We confirm that de novo tension generation occurs as an order-disorder transition during phase 2slow and the equivalent, temperature-sensitive temperature-jump relaxation. PMID:7612845

  16. Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach

    Directory of Open Access Journals (Sweden)

    A. Sumathi Felicita

    Full Text Available ABSTRACT Objective: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. Methods: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. Results: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5o to 16o from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. Conclusion: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.

  17. Effect of Magnetic Field on Entropy Generation Due to Laminar Forced Convection Past a Horizontal Flat Plate

    Directory of Open Access Journals (Sweden)

    Moh'd A. Al-Nimr

    2004-06-01

    Full Text Available Magnetic field effect on local entropy generation due to steady two-dimensional laminar forced convection flow past a horizontal plate was numerically investigated. This study was focused on the entropy generation characteristics and its dependency on various dimensionless parameters. The effect of various dimensionless parameters, such as Hartmann number (Ha, Eckert number (Ec, Prandtl number (Pr, Joule heating parameter (R and the free stream temperature parameter (θ∞ on the entropy generation characteristics is analyzed. The dimensionless governing equations in Cartesian coordinate were solved by an implicit finite difference technique. The solutions were carried out for Ha2=0.5-3, Ec=0.01-0.05, Pr=1-5 and θ∞=1.1-2.5. It was found that, the entropy generation increased with increasing Ha, Ec and R. While, increasing the free stream temperature parameter, and Prandtl number tend to decrease the local entropy generation.

  18. Using Likert-type and ipsative/forced choice items in sequence to generate a preference.

    Science.gov (United States)

    Ried, L Douglas

    2014-01-01

    Collaboration and implementation of a minimum, standardized set of core global educational and professional competencies seems appropriate given the expanding international evolution of pharmacy practice. However, winnowing down hundreds of competencies from a plethora of local, national and international competency frameworks to select the most highly preferred to be included in the core set is a daunting task. The objective of this paper is to describe a combination of strategies used to ascertain the most highly preferred items among a large number of disparate items. In this case, the items were >100 educational and professional competencies that might be incorporated as the core components of new and existing competency frameworks. Panelists (n = 30) from the European Union (EU) and United States (USA) were chosen to reflect a variety of practice settings. Each panelist completed two electronic surveys. The first survey presented competencies in a Likert-type format and the second survey presented many of the same competencies in an ipsative/forced choice format. Item mean scores were calculated for each competency, the competencies were ranked, and non-parametric statistical tests were used to ascertain the consistency in the rankings achieved by the two strategies. This exploratory study presented over 100 competencies to the panelists in the beginning. The two methods provided similar results, as indicated by the significant correlation between the rankings (Spearman's rho = 0.30, P < 0.09). A two-step strategy using Likert-type and ipsative/forced choice formats in sequence, appears to be useful in a situation where a clear preference is required from among a large number of choices. The ipsative/forced choice format resulted in some differences in the competency preferences because the panelists could not rate them equally by design. While this strategy was used for the selection of professional educational competencies in this exploratory study, it is

  19. Alterations in Neural Control of Constant Isometric Contraction with the Size of Error Feedback.

    Directory of Open Access Journals (Sweden)

    Ing-Shiou Hwang

    Full Text Available Discharge patterns from a population of motor units (MUs were estimated with multi-channel surface electromyogram and signal processing techniques to investigate parametric differences in low-frequency force fluctuations, MU discharges, and force-discharge relation during static force-tracking with varying sizes of execution error presented via visual feedback. Fourteen healthy adults produced isometric force at 10% of maximal voluntary contraction through index abduction under three visual conditions that scaled execution errors with different amplification factors. Error-augmentation feedback that used a high amplification factor (HAF to potentiate visualized error size resulted in higher sample entropy, mean frequency, ratio of high-frequency components, and spectral dispersion of force fluctuations than those of error-reducing feedback using a low amplification factor (LAF. In the HAF condition, MUs with relatively high recruitment thresholds in the dorsal interosseous muscle exhibited a larger coefficient of variation for inter-spike intervals and a greater spectral peak of the pooled MU coherence at 13-35 Hz than did those in the LAF condition. Manipulation of the size of error feedback altered the force-discharge relation, which was characterized with non-linear approaches such as mutual information and cross sample entropy. The association of force fluctuations and global discharge trace decreased with increasing error amplification factor. Our findings provide direct neurophysiological evidence that favors motor training using error-augmentation feedback. Amplification of the visualized error size of visual feedback could enrich force gradation strategies during static force-tracking, pertaining to selective increases in the discharge variability of higher-threshold MUs that receive greater common oscillatory inputs in the β-band.

  20. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    Science.gov (United States)

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  2. Technical concept and evaluation of a novel shoulder simulator with adaptive muscle force generation and free motion

    Directory of Open Access Journals (Sweden)

    Verjans Mark

    2016-09-01

    Full Text Available The human shoulder is one of the most complex joints of the human body, and due to the high range of motion and the complex soft tissue apparatus prone to injuries. Surgical therapies and joint replacements often lead to unsatisfactory results. To improve the understanding of the complex biomechanics of the shoulder, experimental investigations have to be conducted. For this purpose a new shoulder simulator with an innovative muscle force generation was developed. On the basis of a modular concept six artificial pneumatic muscles were integrated to represent the functionally most important muscles of the shoulder joint, whereby a free and controlled movement of the humerus can be conducted. For each muscle individual setpoints for muscle length control based on a user defined shoulder movement for any artificial or cadaver specimen are created by manual motion “Teach-In”. Additional to muscle forces and lengths, optical tracking and a joint force measurement is used to enable different biomechanical studies of the shoulder joint. This paper describes the technical setup as well as the control strategy and first results of its experimental functional validation.

  3. Spin force and the generation of sustained spin current in time-dependent Rashba and Dresselhaus systems

    International Nuclear Information System (INIS)

    Ho, Cong Son; Tan, Seng Ghee; Jalil, Mansoor B. A.

    2014-01-01

    The generation of spin current and spin polarization in a two-dimensional electron gas structure is studied in the presence of Dresselhaus and Rashba spin-orbit couplings (SOC), the strength of the latter being modulated in time by an ac gate voltage. By means of the non-Abelian gauge field approach, we established the relation between the Lorentz spin force and the spin current in the SOC system, and showed that the longitudinal component of the spin force induces a transverse spin current. For a constant (time-invariant) Rashba system, we recover the universal spin Hall conductivity of e/(8π) , derived previously via the Berry phase and semi-classical methods. In the case of a time-dependent SOC system, the spin current is sustained even under strong impurity scattering. We evaluated the ac spin current generated by a time-modulated Rashba SOC in the absence of any dc electric field. The magnitude of the spin current reaches a maximum when the modulation frequency matches the Larmor frequency of the electrons

  4. Increased cross-bridge recruitment contributes to transient increase in force generation beyond maximal capacity in human myocardium.

    Science.gov (United States)

    Milani-Nejad, Nima; Chung, Jae-Hoon; Canan, Benjamin D; Fedorov, Vadim V; Whitson, Bryan A; Kilic, Ahmet; Mohler, Peter J; Janssen, Paul M L

    2018-01-01

    Cross-bridge attachment allows force generation to occur, and rate of tension redevelopment (k tr ) is a commonly used index of cross-bridge cycling rate. Tension overshoots have been observed briefly after a slack-restretch k tr maneuver in various species of animal models and humans. In this study, we set out to determine the properties of these overshoots and their possible underlying mechanism. Utilizing human cardiac trabeculae, we have found that tension overshoots are temperature-dependent and that they do not occur at resting states. In addition, we have found that myosin cross-bridge cycle is vital to these overshoots as inhibition of the cycle results in the blunting of the overshoots and the magnitude of the overshoots are dependent on the level of myofilament activation. Lastly, we show that the number of cross-bridges transiently increase during tension overshoots. These findings lead us to conclude that tension overshoots are likely due to a transient enhancement of the recruitment of myosin heads into the cross-bridge cycling, regulated by the myocardium, and with potential physiological significance in determining cardiac output. We show that isolated human myocardium is capable of transiently increasing its maximal force generation capability by increasing cross-bridge recruitment following slack-restretch maneuver. This process can potentially have important implications and significance in cardiac contraction in vivo. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. No Neuromuscular Side-Effects of Scopolamine in Sensorimotor Control and Force-Generating Capacity Among Parabolic Fliers

    Science.gov (United States)

    Ritzmann, Ramona; Freyler, Kathrin; Krause, Anne; Gollhofer, Albert

    2016-10-01

    Scopolamine is used to counteract motion sickness in parabolic flight (PF) experiments. Although the drug's anticholinergic properties effectively impede vomiting, recent studies document other sensory side-effects in the central nervous system that may considerably influence sensorimotor performance. This study aimed to quantify such effects in order to determine if they are of methodological and operational significance for sensorimotor control. Ten subjects of a PF campaign received a weight-sex-based dose of a subcutaneous scopolamine injection. Sensorimotor performance was recorded before medication, 20min, 2h and 4h after injection in four space-relevant paradigms: balance control in one-leg stance with eyes open (protocol 1) and closed as well as force-generating capacity in countermovement jumps and hops (protocol 2). Postural sway, forces and joint angles were recorded. Neuromuscular control was assessed by electromyography and peripheral nerve stimulation; H-reflexes and M-waves were used to monitor spinal excitability of the Ia afferent reflex circuitry and maximal motor output. (1) H-reflex amplitudes, latencies and functional reflexes remained unchanged after scopolamine injection. (2) M-waves, neuromuscular activation intensities and antagonistic muscle coordination did not change with scopolamine administration. (3) Balance performance and force-generating capacity were not impeded by scopolamine. We found no evidence for changes in sensorimotor control in response to scopolamine injection. Sensory processing of daily relevant reflexes, spinal excitability, maximal motor output and performance parameters were not sensitive to the medication. We conclude that scopolamine administration can be used to counteract motion sickness in PF without methodological and operational concerns or interference regarding sensorimotor skills associated with neuromuscular control.

  6. Fatigue in isometric contraction in a single muscle fibre: a compartmental calcium ion flow model.

    Science.gov (United States)

    Kothiyal, K P; Ibramsha, M

    1986-01-01

    Fatigue in muscle is a complex biological phenomenon which has so far eluded a definite explanation. Many biochemical and physiological models have been suggested in the literature to account for the decrement in the ability of muscle to sustain a given level of force for a long time. Some of these models have been critically analysed in this paper and are shown to be not able to explain all the experimental observations. A new compartmental model based on the intracellular calcium ion movement in muscle is proposed to study the mechanical responses of a muscle fibre. Computer simulation is performed to obtain model responses in isometric contraction to an impulse and a train of stimuli of long duration. The simulated curves have been compared with experimentally observed mechanical responses of the semitendinosus muscle fibre of Rana pipiens. The comparison of computed and observed responses indicates that the proposed calcium ion model indeed accounts very well for the muscle fatigue.

  7. Isometric and unitary phase operators: explaining the Villain transform

    International Nuclear Information System (INIS)

    Hemmen, J L van; Wreszinski, Walter F

    2007-01-01

    The Villain transform plays a key role in spin-wave theory, a bosonization of elementary excitations in a system of extensively many Heisenberg spins. Intuitively, it is a representation of the spin operators in terms of an angle and its canonically conjugate angular momentum operator and, as such, has a few nasty boundary-condition twists. We construct an isometric phase representation of spin operators that conveys a precise mathematical meaning to the Villain transform and is related to both classical mechanics and the Pegg-Barnett-Bialynicki-Birula boson (photon) phase operators by means of suitable limits. In contrast to the photon case, unitary extensions are inadequate because they describe the wrong physics. We also discuss in some detail the application to spin-wave theory, pointing out some examples in which the isometric representation is indispensable

  8. Prediction of requirements on labor force in the fuel and power generation sector

    International Nuclear Information System (INIS)

    Kaveckova, R.

    1990-01-01

    One of the aspects of socio-economic assessment of development is quantification of the expected requirements on the number of personnel. Predictions are discussed for the period before the year 2005 for solid fuel mining and treatment, gas production and bitumen mining, power and heat generation and also for the production of electricity and heat by nuclear power plants. They are based on an analysis of past development and the present state, on presumed implementation of various concept variants, on the type structure of nuclear power plants, on the rules of the electric power supply system, and also on foreign materials. It is expected that in 2005, nuclear power will employ 15,654 personnel. (M.D.). 4 tabs., 16 refs

  9. Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography.

    Science.gov (United States)

    Inami, Takayuki; Tsujimura, Toru; Shimizu, Takuya; Watanabe, Takemasa; Lau, Wing Yin; Nosaka, Kazunori

    2017-05-01

    Ultrasound elastography is used to assess muscle hardness or stiffness; however, no previous studies have validated muscle hardness measures using ultrasound strain elastography (SE). This study investigated the relationship between plantar flexor isometric contraction intensity and gastrocnemius hardness assessed by SE. We hypothesised that the muscle would become harder linearly with an increase in the contraction intensity of the plantar flexors. Fifteen young women (20.1 ± 0.8 years) performed isometric contractions of the ankle plantar flexors at four different intensities (25, 50, 75, 100% of maximal voluntary contraction force: MVC) at 0° plantar flexion. Using SE images, the strain ratio (SR) between the muscle and an acoustic coupler (elastic modulus 22.6 kPa) placed over the skin was calculated (muscle/coupler); pennation angle and muscle thickness were measured for the resting and contracting conditions. SR decreased with increasing contraction intensity from rest (1.28 ± 0.20) to 25% (0.99 ± 0.21), 50% (0.61 ± 0.15), 75% (0.34 ± 0.1) and 100% MVC (0.20 ± 0.05). SR decreased linearly (P < 0.05) with increasing MVC from rest to 75% MVC, but levelled off from 75 and 100% MVC. SR was negatively correlated with pennation angle (r = -0.80, P < 0.01) and muscle thickness ( r= -0.78,  P< 0.01). SR appears to represent muscle hardness changes in response to contraction intensity changes, in the assumption that the gastrocnemius muscle contraction intensity is proportional to the plantar flexion intensity. We concluded that gastrocnemius muscle hardness changes could be validly assessed by SR, and the force-hardness relationship was not linear.

  10. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  11. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  12. Temporal summation of heat pain modulated by isometric exercise.

    Science.gov (United States)

    Koltyn, K F; Knauf, M T; Brellenthin, A G

    2013-08-01

    Little is known about the effects of isometric exercise on temporal summation of heat pain. Thus, the purposes of study 1 and study 2 were to examine the influence of exhaustive and non-exhaustive isometric exercise on temporal summation of heat pain in men and women. Forty-four men and 44 women (mean age = 20 years) completed an informed consent document and a packet of questionnaires. Ten heat pulses were applied to the thenar eminence of the dominant hand using a standardized temporal summation protocol. Participants rated the intensity of the heat pulses using a 0-100 pain rating scale before and following isometric exercise consisting of squeezing a hand dynamometer at 40% of maximal voluntary contraction (MVC) to exhaustion (exhaustive exercise, study 1) and at 25% MVC for 3 min (non-exhaustive exercise, study 2). Muscle pain and perceived exertion were rated every 30 s during exercise using validated rating scales. The data were analysed with repeated measures analysis of variance. The results indicated there were no sex differences (p > 0.05) in time to exhaustion (study 1), muscle pain or perceived exertion (studies 1 and 2). There was a significant reduction (p heat pain in men and women. © 2012 European Federation of International Association for the Study of Pain Chapters.

  13. Jaw-muscle fiber architecture in tufted capuchins favors generating relatively large muscle forces without compromising jaw gape

    Science.gov (United States)

    Taylor, Andrea B.; Vinyard, Christopher J.

    2009-01-01

    Cebus apella is renowned for its dietary flexibility and capacity to exploit hard and tough objects. Cebus apella differs from other capuchins in displaying a suite of craniodental features that have been functionally and adaptively linked to their feeding behavior, particularly the generation and dissipation of relatively large jaw forces. We compared fiber architecture of the masseter and temporalis muscles between the tufted capuchin (C. apella; n = 12 ) and two “untufted” capuchins (C. capuchinus, n = 3; C. albifrons, n = 5). These three species share broadly similar diets, but tufted capuchins occasionally exploit mechanically challenging tissues. We tested the hypothesis that C. apella exhibits architectural properties of their jaw muscles that facilitate relatively large forces, including relatively greater physiologic cross-sectional areas (PCSA), more pinnate fibers, and lower ratios of mass to tetanic tension (Mass/P0). Results show some evidence supporting these predictions, as C. apella has relatively greater superficial masseter, whole masseter, and temporalis PCSAs, significantly so only for the temporalis following Bonferroni adjustment. Capuchins did not differ in pinnation angle or Mass/P0. As an architectural trade-off between maximizing muscle force and muscle excursion/contraction velocity, we also tested the hypothesis that C. apella exhibits relatively shorter muscle fibers. Contrary to our prediction, there are no significant differences in relative fiber lengths between tufted and untufted capuchins. Therefore, we attribute the relatively greater PCSAs in C. apella primarily to their larger muscle masses. These findings suggest that relatively large jaw-muscle PCSAs can be added to the suite of masticatory features that have been functionally linked to the exploitation of a more resistant diet by C. apella. By enlarging jaw-muscle mass to increase PCSA, rather than reducing fiber lengths and increasing pinnation, tufted capuchins appear

  14. Apoptosis generates mechanical forces that close the lens vesicle in the chick embryo

    Science.gov (United States)

    Oltean, Alina; Taber, Larry A.

    2018-03-01

    During the initial stages of eye development, optic vesicles grow laterally outward from both sides of the forebrain and come into contact with the surrounding surface ectoderm (SE). Within the region of contact, these layers then thicken locally to create placodes and invaginate to form the optic cup (primitive retina) and lens vesicle (LV), respectively. This paper examines the biophysical mechanisms involved in LV formation, which consists of three phases: (1) lens placode formation; (2) invagination to create the lens pit (LP); and (3) closure to form a complete ellipsoidally shaped LV. Previous studies have suggested that extracellular matrix deposited between the SE and optic vesicle causes the lens placode to form by locally constraining expansion of the SE as it grows, while actomyosin contraction causes this structure to invaginate. Here, using computational modeling and experiments on chick embryos, we confirm that these mechanisms for Phases 1 and 2 are physically plausible. Our results also suggest, however, that they are not sufficient to close the LP during Phase 3. We postulate that apoptosis provides an additional mechanism by removing cells near the LP opening, thereby decreasing its circumference and generating tension that closes the LP. This hypothesis is supported by staining that shows a ring of cell death located around the LP opening during closure. Inhibiting apoptosis in cultured embryos using caspase inhibitors significantly reduced LP closure, and results from a finite-element model indicate that closure driven by cell death is plausible. Taken together, our results suggest an important mechanical role for apoptosis in lens development.

  15. Isometric hip muscle strength in posttraumatic below-knee amputees

    Directory of Open Access Journals (Sweden)

    Jandrić Slavica

    2007-01-01

    Full Text Available Background/Aim. Traumas and war injuries, next to chronic occlusive artery disease and diabetes mellitus-derived complications, are the most frequent cause of the lower limbs amputation. They affect mostly younger population that need a higher level of activities as compared with the elderly. Medical rehabilitation is very significant for the muscle performance improvement in this population providing their social reintegration. The aim of this study was to investigate the effect of below-knee amputation on the hip isometric muscle strength and effect of rehabilitation on improvement of hip muscle strength in below-knee amputees, secondary to war wounding. Methods. Forty below-knee amputees (after war wounding, average age 35.6±10.6 years, that were included in primary rehabilitation program with prosthetics, were examined. Objective parameters were used to evaluate therapeutical effects. Isometric muscle strength of hip flexors, extensors, abductors and adductors was measured by dynamometer and expressed in Newton (N at admission, control and discharge for each patient. Average length of the treatment was 51 ± 34.1 days. Results. For isometric hip flexors (t = - 1.99346, p < 0.05, extensors (t = -4.629073, p < 0.001, abductors (t = -4.9408, p < 0.001 and adductors (t = -2.00228, p < 0.05, muscle strength was significantly less on the amputated than on nonamputated side. The highest differences in muscle strength between amputated and nonamputated limbs were noted for hip abductors (26.6% and extensors (23.3%. There was significant improvement of mean values of strength for all examined hip muscles after rehabilitation and prosthetics for both legs in comparison to beginning of the therapy. The hip abductor on the amputated side was for 19.4% weaker after rehabilitation in comparison to the nonamputated limb. Conclusion. Decreases of isometric muscle strength in all examined hip muscles were observed, more in the amputated limb. Rehabilitation

  16. WIND TUNNEL RESEARCH ON THE INFLUENCE OF ACTIVE AIRFLOW ON THE LIFT FORCE GENERATED BY THE AIRFOIL

    Directory of Open Access Journals (Sweden)

    Paweł Magryta

    2013-09-01

    Full Text Available The paper discusses the results of wind tunnel tests of airfoils with additional active airflow applied to their upper surfaces. These studies were carried out for a range of velocities up to 28 m/s in an open wind tunnel. Several types of airfoils selected for the examination feature different geometries and are widely applied in today’s aviation industry. The changes in the lift and drag force generated by these airfoils were recorded during the study. The test bench for the tests was equipped with a compressor and a vacuum pump to enable airflow through some holes on the airfoil upper surface. A rapid prototyping method and a 3D printer based on a powder printing technique were applied to print the airfoils. All of their surfaces were subject to surface grinding to smooth their external surfaces. The wind tunnel tests with and without active airflow applied to airfoils are summarised in the paper.

  17. Characterization of polymer surface structure and surface mechanical behaviour by sum frequency generation surface vibrational spectroscopy and atomic force microscopy

    International Nuclear Information System (INIS)

    Opdahl, Aric; Koffas, Telly S; Amitay-Sadovsky, Ella; Kim, Joonyeong; Somorjai, Gabor A

    2004-01-01

    Sum frequency generation (SFG) vibrational spectroscopy and atomic force microscopy (AFM) have been used to study polymer surface structure and surface mechanical behaviour, specifically to study the relationships between the surface properties of polymers and their bulk compositions and the environment to which the polymer is exposed. The combination of SFG surface vibrational spectroscopy and AFM has been used to study surface segregation behaviour of polyolefin blends at the polymer/air and polymer/solid interfaces. SFG surface vibrational spectroscopy and AFM experiments have also been performed to characterize the properties of polymer/liquid and polymer/polymer interfaces, focusing on hydrogel materials. A method was developed to study the surface properties of hydrogel contact lens materials at various hydration conditions. Finally, the effect of mechanical stretching on the surface composition and surface mechanical behaviour of phase-separated polyurethanes, used in biomedical implant devices, has been studied by both SFG surface vibrational spectroscopy and AFM. (topical review)

  18. Enhanced contractile force generation by artificial skeletal muscle tissues using IGF-I gene-engineered myoblast cells.

    Science.gov (United States)

    Sato, Masanori; Ito, Akira; Kawabe, Yoshinori; Nagamori, Eiji; Kamihira, Masamichi

    2011-09-01

    The aim of this study was to investigate whether insulin-like growth factor (IGF)-I gene delivery to myoblast cells promotes the contractile force generated by hydrogel-based tissue-engineered skeletal muscles in vitro. Two retroviral vectors allowing doxycycline (Dox)-inducible expression of the IGF-I gene were transduced into mouse myoblast C2C12 cells to evaluate the effects of IGF-I gene expression on these cells. IGF-I gene expression stimulated the proliferation of C2C12 cells, and a significant increase in the growth rate was observed for IGF-I-transduced C2C12 cells with Dox addition, designated C2C12/IGF (Dox+) cells. Quantitative morphometric analyses showed that the myotubes induced from C2C12/IGF (Dox+) cells had a larger area and a greater width than control myotubes induced from normal C2C12 cells. Artificial skeletal muscle tissues were prepared from the respective cells using hydrogels composed of type I collagen and Matrigel. Western blot analyses revealed that the C2C12/IGF (Dox+) tissue constructs showed activation of a skeletal muscle hypertrophy marker (Akt) and enhanced expression of muscle-specific markers (myogenin, myosin heavy chain and tropomyosin). Moreover, the creatine kinase activity was increased in the C2C12/IGF (Dox+) tissue constructs. The C2C12/IGF (Dox+) tissue constructs contracted in response to electrical pulses, and generated a significantly higher physical force than the control C2C12 tissue constructs. These findings indicate that IGF-I gene transfer has the potential to yield functional skeletal muscle substitutes that are capable of in vivo restoration of the load-bearing function of injured muscle or acting as in vitro electrically-controlled bio-actuators. Copyright © 2011 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  19. Near-field multiple traps of paraxial acoustic vortices with strengthened gradient force generated by sector transducer array

    Science.gov (United States)

    Wang, Qingdong; Li, Yuzhi; Ma, Qingyu; Guo, Gepu; Tu, Juan; Zhang, Dong

    2018-01-01

    In order to improve the capability of particle trapping close to the source plane, theoretical and experimental studies on near-field multiple traps of paraxial acoustic vortices (AVs) with a strengthened acoustic gradient force (AGF) generated by a sector transducer array were conducted. By applying the integration of point source radiation, numerical simulations for the acoustic fields generated by the sector transducer array were conducted and compared with those produced by the circular transducer array. It was proved that strengthened AGFs of near-field multiple AVs with higher peak pressures and smaller vortex radii could be produced by the sector transducer array with a small topological charge. The axial distributions of the equivalent potential gradient indicated that the AGFs of paraxial AVs in the near field were much higher than those in the far field, and the distances at the near-field vortex antinodes were also proved to be the ideal trapping positions with relatively higher AGFs. With the established 8-channel AV generation system, theoretical studies were also verified by the experimental measurements of pressure and phase for AVs with various topological charges. The formation of near-field multiple paraxial AVs was verified by the cross-sectional circular pressure distributions with perfect phase spirals around central pressure nulls, and was also proved by the vortex nodes and antinodes along the center axis. The favorable results demonstrated the feasibility of generating near-field multiple traps of paraxial AVs with strengthened AGF using the sector transducer array, and suggested the potential applications of close-range particle trapping in biomedical engineering.

  20. Generation of an electromotive force by hydrogen-to-water oxidation with Pt-coated oxidized titanium foils

    Energy Technology Data Exchange (ETDEWEB)

    Schierbaum, Klaus; El Achhab, Mhamed [Department of Materials Science, Institute for Experimental Condensed Matter Physics, Heinrich-Heine University, 40225 Duesseldorf, Universitaetsstrasse 1 (Germany)

    2011-12-15

    We show that chemically induced current densities up to 20 mA cm{sup -2} and an electromotive force (EMF) up to 465 mV are generated during the hydrogen-to-water-oxidation over Pt/TiO{sub 2}/Ti devices. We prepare the samples by plasma electrolytic oxidation (PEO) of titanium foils and deposition of Pt contact paste. This process yields porous structures and, depending on the anodization voltage, Schottky diode-type current-voltage curves of various ideality parameters. Our experiments demonstrate that Pt coated anodized titanium can also be utilized as hydrogen sensor; the system offers a number of advantages such as a wide temperature range of operation from -40 to 80 C, quick response and decay times of signals, and good electrical stability. Idealized sketch of the Pt coated anodized Ti foil and application as hydrogen sensor and electric generator. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Motor units in vastus lateralis and in different vastus medialis regions show different firing properties during low-level, isometric knee extension contraction.

    Science.gov (United States)

    de Souza, Leonardo Mendes Leal; Cabral, Hélio Veiga; de Oliveira, Liliam Fernandes; Vieira, Taian Martins

    2018-04-01

    Architectural differences along vastus medialis (VM) and between VM and vastus lateralis (VL) are considered functionally important for the patellar tracking, knee joint stability and knee joint extension. Whether these functional differences are associated with a differential activity of motor units between VM and VL is however unknown. In the present study, we, therefore, investigate neuroanatomical differences in the activity of motor units detected proximo-distally from VM and from the VL muscle. Nine healthy volunteers performed low-level isometric knee extension contractions (20% of their maximum voluntary contraction) following a trapezoidal trajectory. Surface electromyograms (EMGs) were recorded from VM proximal and distal regions and from VL using three linear adhesive arrays of eight electrodes. The firing rate and recruitment threshold of motor units decomposed from EMGs were then compared among muscle regions. Results show that VL motor units reached lower mean firing rates in comparison with VM motor units, regardless of their position within VM (P motor units (P = .997). Furthermore, no significant differences in the recruitment threshold were observed for all motor units analysed (P = .108). Our findings possibly suggest the greater potential of VL to generate force, due to its fibres arrangement, may account for the lower discharge rate observed for VL then either proximally or distally detected motor units in VM. Additionally, the present study opens new perspectives on the importance of considering muscle architecture in investigations of the neural aspects of motor behaviour. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The influence of isometric preload on power expressed during bench press in strength-trained men.

    Science.gov (United States)

    Bartolomei, Sandro; Fukuda, David H; Hoffman, Jay R; Stout, Jeffrey R; Merni, Franco

    2017-03-01

    The purpose of this study was to compare the power expressed during the bench press exercise in resistance-trained men following different pre-activation conditions. Twenty-two trained men (age 24.1 ± 1.7 years, height 178.6 ± 6.1 cm, body mass 81.1 ± 10.6 kg) completed a maximal effort bench press (1-RM) test (100.0 kg ± 8.1 kg). In a subsequent assessment, each participant performed concentric bench press movements with loads of 20%, 30%, 40% and 50% of their 1-RM preceded by either a concentric contraction (CC), a low isometric preload (LIP; 70% 1-RM) or a high isometric preload (HIP; 100% 1-RM) conditions. All movements were performed in a Smith machine with a settable quick-release device. Participants performed all three conditions in randomized fashion. Results indicated that power outputs during the bench press exercise following HIP were significantly (p < 0.05) greater than CC at 20% 1-RM (+9%), 30% 1-RM (+16%) and 40% 1-RM (+14%), and LIP at 20% 1-RM (+4%), 30% 1-RM (+20%) and 40% 1-RM (+15%). No differences were found between conditions at 50% 1-RM. Area under the force-power curve with HIP was greater (p < 0.05) than with CC and LIP. In conclusion, results of this study indicate that the use of a HIP (100% 1-RM) in trained participants results in significantly greater power output during the concentric phase of a multi-joint exercise when compared to standard concentric movement.

  3. Tide generating forces

    Digital Repository Service at National Institute of Oceanography (India)

    Unnikrishnan, A.S.

    stream_size 3 stream_content_type text/plain stream_name Trg_Calculat_Water_Depth_Chart_Datum_1991_3.pdf.txt stream_source_info Trg_Calculat_Water_Depth_Chart_Datum_1991_3.pdf.txt Content-Encoding ISO-8859-1 Content-Type text...

  4. Grandparenting and mothers' labour force participation: A comparative analysis using the Generations and Gender Survey

    Directory of Open Access Journals (Sweden)

    Arnstein Aassve

    2012-07-01

    Full Text Available BACKGROUND It is well known that the provision of public childcare plays an important role for women labour force participation and its availability varies tremendously across countries. In many countries, informal childcare is also important and typically provided by the grandparents, but its role on mothers' employment is not yet well understood. Understanding the relationship between labour supply decisions and grandparental childcare is complex. While the provision of grandparental childcare is clearly a function of the social and institutional context of a country, it also depends on family preferences, which are typically unobserved in surveys. OBJECTIVE We analyze the role of informal childcare provided by grandparents on mothers' labour force participation keeping unobserved preferences into account. METHODS Bivariate probit models with instrumental variables are estimated on data from seven countries (Bulgaria, France, Georgia, Germany, Hungary, Russia and The Netherlands drawn from the Generations and Gender Survey. RESULTS We find that only in some countries mothers' employment is positively and significantly associated with grandparents providing childcare. In other countries, once we control for unobserved preferences, we do not find this effect. CONCLUSIONS The role of grandparents is an important element to reconcile work and family for women in some countries. Our results show the importance of considering family preferences and country differences when studying the relationship between grandparental childcare and mothers' labour supply. COMMENTS Our results are consistent with previous research on this topic. However, differently from previous studies, we conduct separate analyses by country and show that the effect of grandparental childcare varies considerably. The fact that we also include in the analyses Bulgaria, Hungary, Russia and Georgia is an important novelty as there are no studies on this issue

  5. Inhibition of xanthine oxidase reduces oxidative stress and improves skeletal muscle function in response to electrically stimulated isometric contractions in aged mice

    Science.gov (United States)

    Ryan, Michael J.; Jackson, Janna R.; Hao, Yanlei; Leonard, Stephen S.; Alway, Stephen E.

    2012-01-01

    Oxidative stress is a putative factor responsible for reducing function and increasing apoptotic signaling in skeletal muscle with aging. This study examined the contribution and functional significance of the xanthine oxidase enzyme as a potential source of oxidant production in aged skeletal muscle during repetitive in situ electrically stimulated isometric contractions. Xanthine oxidase activity was inhibited in young adult and aged mice via a subcutaneously placed time release (2.5 mg/day) allopurinol pellet, 7 days prior to the start of in situ electrically stimulated isometric contractions. Gastrocnemius muscles were electrically activated with 20 maximal contractions for three consecutive days. Xanthine oxidase activity was 65% greater in the gastrocnemius muscle of aged mice compared to young mice. Xanthine oxidase activity also increased after in situ electrically stimulated isometric contractions in muscles from both young (33%) and aged (28%) mice, relative to contralateral non-contracted muscles. Allopurinol attenuated the exercise-induced increase in oxidative stress, but it did not affect the elevated basal levels of oxidative stress that was associated with aging. In addition, inhibition of xanthine oxidase activity decreased caspase 3 activity, but it had no effect on other markers of mitochondrial associated apoptosis. Our results show that compared to control conditions, suppression of xanthine oxidase activity by allopurinol reduced xanthine oxidase activity, H2O2 levels, lipid peroxidation and caspase-3 activity, prevented the in situ electrically stimulated isometric contraction-induced loss of glutathione, prevented the increase of catalase and copper-zinc superoxide dismutase activities, and increased maximal isometric force in the plantar flexor muscles of aged mice after repetitive electrically evoked contractions. PMID:21530649

  6. Comparison of the ballistic contractile responses generated during microstimulation of single human motor axons with brief irregular and regular stimuli.

    Science.gov (United States)

    Leitch, Michael; Macefield, Vaughan G

    2017-08-01

    Ballistic contractions are induced by brief, high-frequency (60-100 Hz) trains of action potentials in motor axons. During ramp voluntary contractions, human motoneurons exhibit significant discharge variability of ∼20% and have been shown to be advantageous to the neuromuscular system. We hypothesized that ballistic contractions incorporating discharge variability would generate greater isometric forces than regular trains with zero variability. High-impedance tungsten microelectrodes were inserted into human fibular nerve, and single motor axons were stimulated with both irregular and constant-frequency stimuli at mean frequencies ranging from 57.8 to 68.9 Hz. Irregular trains generated significantly greater isometric peak forces than regular trains over identical mean frequencies. The high forces generated by ballistic contractions are not based solely on high frequencies, but rather a combination of high firing rates and discharge irregularity. It appears that irregular ballistic trains take advantage of the "catchlike property" of muscle, allowing augmentation of force. Muscle Nerve 56: 292-297, 2017. © 2016 Wiley Periodicals, Inc.

  7. Effects of fatiguing isometric and isokinetic ankle exercises on postural control while standing on firm and compliant surfaces.

    Science.gov (United States)

    Bisson, Etienne J; Remaud, Anthony; Boyas, Sébastien; Lajoie, Yves; Bilodeau, Martin

    2012-06-14

    Fatiguing exercises used across studies to induce alterations in postural control are diverse and may explain the different findings reported. This study aimed to compare the effects of two types of fatiguing plantarflexion exercises on postural control on a firm and a compliant surface. Ten healthy young men (29 ± 4 years) were asked to stand as steadily as possible for 30 s, blindfolded with feet together, on a firm and a compliant surface before and immediately after an isometric and an isokinetic fatiguing exercise. Maximal force reduction due to fatigue was found significant but similar between exercises. No significant difference was found between the fatiguing exercises on all Center of Pressure (CoP) parameters. Both fatiguing exercises induced increases in CoP excursion area, CoP variability and CoP velocity in both planes (antero-posterior, mediolateral) on the compliant surface. On the firm surface, both fatiguing exercises only induced increases in CoP variability and CoP velocity in the fatigued plane (antero-posterior). Isometric and isokinetic fatiguing exercises, when producing a similar level of force reduction, induce similar decreases in postural control. The effects of fatigue on postural control in healthy young men are more pronounced when standing on a compliant surface, i.e. when proprioceptive information at the ankle is altered.

  8. Development, validity and reliability of a new pressure air biofeedback device (PAB) for measuring isometric extension strength of the lumbar spine.

    Science.gov (United States)

    Pienaar, Andries W; Barnard, Justhinus G

    2017-04-01

    This study describes the development of a new portable muscle testing device, using air pressure as a biofeedback and strength testing tool. For this purpose, a pressure air biofeedback device (PAB ® ) was developed to measure and record the isometric extension strength of the lumbar multifidus muscle in asymptomatic and low back pain (LBP) persons. A total of 42 subjects (age 47.58 years, ±18.58) participated in this study. The validity of PAB ® was assessed by comparing a selected measure, air pressure force in millibar (mb), to a standard criterion; calibrated weights in kilograms (kg) during day-to-day tests. Furthermore, clinical trial-to-trial and day-to-day tests of maximum voluntary isometric contraction (MVIC) of L5 lumbar multifidus were done to compare air pressure force (mb) to electromyography (EMG) in microvolt (μV) and to measure the reliability of PAB ® . A highly significant relationship were found between air pressure output (mb) and calibrated weights (kg). In addition, Pearson correlation calculations showed a significant relationship between PAB ® force (mb) and EMG activity (μV) for all subjects (n = 42) examined, as well as for the asymptomatic group (n = 24). No relationship was detected for the LBP group (n = 18). In terms of lumbar extension strength, we found that asymptomatic subjects were significantly stronger than LBP subjects. The results of the PAB ® test differentiated between LBP and asymptomatic subject's lumbar isometric extension strength without any risk to the subjects and also indicate that the lumbar isometric extension test with the new PAB ® device is reliable and valid.

  9. NRC Fact-Finding Task Force report on the ATWS event at Salem Nuclear Generating Station, Unit 1, on February 25, 1983

    International Nuclear Information System (INIS)

    1983-03-01

    An NRC Region I Task Force was established on March 1, 1983 to conduct fact finding and data collection with regard to the circumstances which led to an anticipated transient without scram (ATWS) event at the Public Service Electric and Gas Company's Salem Generating Station, Unit 1 on February 25, 1983. The charter of the Task Force was to determine the factual information pertinent to management and administrative controls which should have ensured proper operation of the reactor trip breakers in the solid state protection system. This report documents the findings of the Task Force along with its conclusions

  10. Effect of knee and trunk angle on kinetic variables during the isometric midthigh pull: test-retest reliability.

    Science.gov (United States)

    Comfort, Paul; Jones, Paul A; McMahon, John J; Newton, Robert

    2015-01-01

    The isometric midthigh pull (IMTP) has been used to monitor changes in force, maximum rate of force development (mRFD), and impulse, with performance in this task being associated with performance in athletic tasks. Numerous postures have been adopted in the literature, which may affect the kinetic variables during the task; therefore, the aim of this investigation was to determine whether different knee-joint angles (120°, 130°, 140°, and 150°) and hip-joint angles (125° and 145°), including the subjects preferred posture, affect force, mRFD, and impulse during the IMTP. Intraclass correlation coefficients demonstrated high within-session reliability (r ≥ .870, P kinetic variables determined in all postures, excluding impulse measures during the 130° knee-flexion, 125° hip-flexion posture, which showed a low to moderate reliability (r = .666-.739, P .819, P kinetic variables. There were no significant differences in peak force (P > .05, Cohen d = 0.037, power = .408), mRFD (P > .05, Cohen d = 0.037, power = .409), or impulse at 100 ms (P > .05, Cohen d = 0.056, power = .609), 200 ms (P > .05, Cohen d = 0.057, power = .624), or 300 ms (P > .05, Cohen d = 0.061, power = .656) across postures. Smallest detectable differences demonstrated that changes in performance of >1.3% in peak isometric force, >10.3% in mRFD, >5.3% in impulse at 100 ms, >4.4% in impulse at 200 ms, and >7.1% in impulse at 300 ms should be considered meaningful, irrespective of posture.

  11. The effects of biting and pulling on the forces generated during feeding in the Komodo dragon (Varanus komodoensis.

    Directory of Open Access Journals (Sweden)

    Domenic C D'Amore

    Full Text Available In addition to biting, it has been speculated that the forces resulting from pulling on food items may also contribute to feeding success in carnivorous vertebrates. We present an in vivo analysis of both bite and pulling forces in Varanus komodoensis, the Komodo dragon, to determine how they contribute to feeding behavior. Observations of cranial modeling and behavior suggest that V. komodoensis feeds using bite force supplemented by pulling in the caudal/ventrocaudal direction. We tested these observations using force gauges/transducers to measure biting and pulling forces. Maximum bite force correlates with both body mass and total body length, likely due to increased muscle mass. Individuals showed consistent behaviors when biting, including the typical medial-caudal head rotation. Pull force correlates best with total body length, longer limbs and larger postcranial motions. None of these forces correlated well with head dimensions. When pulling, V. komodoensis use neck and limb movements that are associated with increased caudal and ventral oriented force. Measured bite force in Varanus komodoensis is similar to several previous estimations based on 3D models, but is low for its body mass relative to other vertebrates. Pull force, especially in the ventrocaudal direction, would allow individuals to hunt and deflesh with high success without the need of strong jaw adductors. In future studies, pull forces need to be considered for a complete understanding of vertebrate carnivore feeding dynamics.

  12. The effects of biting and pulling on the forces generated during feeding in the Komodo dragon (Varanus komodoensis).

    Science.gov (United States)

    D'Amore, Domenic C; Moreno, Karen; McHenry, Colin R; Wroe, Stephen

    2011-01-01

    In addition to biting, it has been speculated that the forces resulting from pulling on food items may also contribute to feeding success in carnivorous vertebrates. We present an in vivo analysis of both bite and pulling forces in Varanus komodoensis, the Komodo dragon, to determine how they contribute to feeding behavior. Observations of cranial modeling and behavior suggest that V. komodoensis feeds using bite force supplemented by pulling in the caudal/ventrocaudal direction. We tested these observations using force gauges/transducers to measure biting and pulling forces. Maximum bite force correlates with both body mass and total body length, likely due to increased muscle mass. Individuals showed consistent behaviors when biting, including the typical medial-caudal head rotation. Pull force correlates best with total body length, longer limbs and larger postcranial motions. None of these forces correlated well with head dimensions. When pulling, V. komodoensis use neck and limb movements that are associated with increased caudal and ventral oriented force. Measured bite force in Varanus komodoensis is similar to several previous estimations based on 3D models, but is low for its body mass relative to other vertebrates. Pull force, especially in the ventrocaudal direction, would allow individuals to hunt and deflesh with high success without the need of strong jaw adductors. In future studies, pull forces need to be considered for a complete understanding of vertebrate carnivore feeding dynamics.

  13. Myostatin dysfunction impairs force generation in extensor digitorum longus muscle and increases exercise-induced protein efflux from extensor digitorum longus and soleus muscles.

    Science.gov (United States)

    Baltusnikas, Juozas; Kilikevicius, Audrius; Venckunas, Tomas; Fokin, Andrej; Bünger, Lutz; Lionikas, Arimantas; Ratkevicius, Aivaras

    2015-08-01

    Myostatin dysfunction promotes muscle hypertrophy, which can complicate assessment of muscle properties. We examined force generating capacity and creatine kinase (CK) efflux from skeletal muscles of young mice before they reach adult body and muscle size. Isolated soleus (SOL) and extensor digitorum longus (EDL) muscles of Berlin high (BEH) mice with dysfunctional myostatin, i.e., homozygous for inactivating myostatin mutation, and with a wild-type myostatin (BEH+/+) were studied. The muscles of BEH mice showed faster (P myostatin dysfunction leads to impairment in muscle force generating capacity in EDL and increases susceptibility of SOL and EDL to protein loss after exercise.

  14. One Point Isometric Matching with the Heat Kernel

    KAUST Repository

    Ovsjanikov, Maks

    2010-09-21

    A common operation in many geometry processing algorithms consists of finding correspondences between pairs of shapes by finding structure-preserving maps between them. A particularly useful case of such maps is isometries, which preserve geodesic distances between points on each shape. Although several algorithms have been proposed to find approximately isometric maps between a pair of shapes, the structure of the space of isometries is not well understood. In this paper, we show that under mild genericity conditions, a single correspondence can be used to recover an isometry defined on entire shapes, and thus the space of all isometries can be parameterized by one correspondence between a pair of points. Perhaps surprisingly, this result is general, and does not depend on the dimensionality or the genus, and is valid for compact manifolds in any dimension. Moreover, we show that both the initial correspondence and the isometry can be recovered efficiently in practice. This allows us to devise an algorithm to find intrinsic symmetries of shapes, match shapes undergoing isometric deformations, as well as match partial and incomplete models efficiently. Journal compilation © 2010 The Eurographics Association and Blackwell Publishing Ltd.

  15. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  16. Recommendations concerning Tennessee's hazardous waste management policies by a task force representing generators, environmentalists, and other key constituencies

    International Nuclear Information System (INIS)

    Colglazier, E.W.; English, M.R.

    1987-01-01

    Four recommendations are proposed. 1) A Governor's Roundtable on Hazardous and Solid Wastes should be established to ensure that Tennessee have sound policies and plans for waste management, adequate waste treatment and disposal capacity, and the means to meet the October, 1989 deadline for certification of hazardous waste capacity. 2) Opportunities for early public information and participation in Tennessee's RCRA permitting process should be improved. 3) A Superfund Public Involvement Task Force should be appointed by the Commissioner of Health and Environment to find ways to ensure that a community affected by a Tennessee Superfund site has early and adequate opportunities for information and involvement. 4) Communications about hazardous waste issues should be improved by the appointment of a hazardous waste information officer, the establishment of a Speakers Bureau, the funding of the UT Center for Industrial Services' Hazardous Waste Extension Program, establishment of a crisis situation network of consultants for communities, and exploration of the possibility of Amnesty Days for household hazardous waste and for small-quantity generators waste

  17. Analyzing driving forces behind changes in energy vulnerability of Spanish electricity generation through a Divisia index-based method

    International Nuclear Information System (INIS)

    Fernández González, P.; Moreno, B.

    2015-01-01

    Highlights: • We propose and develop the LMDI approach to factorize changes in electricity bill vulnerability. • Spanish vulnerability (1995–2011) markedly grew mainly by increasing gas dependence. • Fuel price increase and growing importance of electricity damage energy security. • Energy intensity advances & fuel diversification: insufficient to drive vulnerability. • Main recommendation: enhance internal energy market and common external EU strategy. - Abstract: High energy dependence on fossil raises vulnerability concerns about security of supply and energy cost. This research examines the impact of high dependence of imported fuels for power generation in Spain through the quantification and analysis of the driving forces behind the change in its electricity bill. Following logarithmic mean Divisia indexes approach, we present and perform a new method that enables a complete decomposition of changes in electricity vulnerability into contributions from several drivers. In fact, we identify five predefined factors behind the variations in vulnerability in Spain during the 1998–2011 period: fuel price, average heat rate, fuel dependence, degree of electricity importance and energy intensity. The application of this approach reveals a significant increase in Spanish vulnerability in the last two decades, promoted by increments in fuel price and importance of electricity over the primary energy consumption, but especially by increasing fuel dependence (particularly gas dependence). Therefore, findings mainly advocate for those strategies aimed at reducing Spanish energy dependence. Also those improving thermal efficiency and energy intensity are indicated

  18. Eccentric Contraction-Induced Muscle Injury: Reproducible, Quantitative, Physiological Models to Impair Skeletal Muscle's Capacity to Generate Force.

    Science.gov (United States)

    Call, Jarrod A; Lowe, Dawn A

    2016-01-01

    In order to investigate the molecular and cellular mechanisms of muscle regeneration an experimental injury model is required. Advantages of eccentric contraction-induced injury are that it is a controllable, reproducible, and physiologically relevant model to cause muscle injury, with injury being defined as a loss of force generating capacity. While eccentric contractions can be incorporated into conscious animal study designs such as downhill treadmill running, electrophysiological approaches to elicit eccentric contractions and examine muscle contractility, for example before and after the injurious eccentric contractions, allows researchers to circumvent common issues in determining muscle function in a conscious animal (e.g., unwillingness to participate). Herein, we describe in vitro and in vivo methods that are reliable, repeatable, and truly maximal because the muscle contractions are evoked in a controlled, quantifiable manner independent of subject motivation. Both methods can be used to initiate eccentric contraction-induced injury and are suitable for monitoring functional muscle regeneration hours to days to weeks post-injury.

  19. Air-coupled acoustic radiation force for non-contact generation of broadband mechanical waves in soft media

    Energy Technology Data Exchange (ETDEWEB)

    Ambroziński, Łukasz [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); AGH University of Science and Technology, Krakow 30059 (Poland); Pelivanov, Ivan, E-mail: ivanp3@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Faculty of Physics, Moscow State University, Moscow 119991 (Russian Federation); Song, Shaozhen; Yoon, Soon Joon; Gao, Liang; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Li, David [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Chemical Engineering, University of Washington Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K. [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-07-25

    A non-contact method for efficient, non-invasive excitation of mechanical waves in soft media is proposed, in which we focus an ultrasound (US) signal through air onto the surface of a medium under study. The US wave reflected from the air/medium interface provides radiation force to the medium surface that launches a transient mechanical wave in the transverse (lateral) direction. The type of mechanical wave is determined by boundary conditions. To prove this concept, a home-made 1 MHz piezo-ceramic transducer with a matching layer to air sends a chirped US signal centered at 1 MHz to a 1.6 mm thick gelatin phantom mimicking soft biological tissue. A phase-sensitive (PhS)-optical coherence tomography system is used to track/image the mechanical wave. The reconstructed transient displacement of the mechanical wave in space and time demonstrates highly efficient generation, thus offering great promise for non-contact, non-invasive characterization of soft media, in general, and for elasticity measurements in delicate soft tissues and organs in bio-medicine, in particular.

  20. NON-NEUTRALIZED ELECTRIC CURRENT PATTERNS IN SOLAR ACTIVE REGIONS: ORIGIN OF THE SHEAR-GENERATING LORENTZ FORCE

    International Nuclear Information System (INIS)

    Georgoulis, Manolis K.; Titov, Viacheslav S.; Mikić, Zoran

    2012-01-01

    Using solar vector magnetograms of the highest available spatial resolution and signal-to-noise ratio, we perform a detailed study of electric current patterns in two solar active regions (ARs): a flaring/eruptive and a flare-quiet one. We aim to determine whether ARs inject non-neutralized (net) electric currents in the solar atmosphere, responding to a debate initiated nearly two decades ago that remains inconclusive. We find that well-formed, intense magnetic polarity inversion lines (PILs) within ARs are the only photospheric magnetic structures that support significant net current. More intense PILs seem to imply stronger non-neutralized current patterns per polarity. This finding revises previous works that claim frequent injections of intense non-neutralized currents by most ARs appearing in the solar disk but also works that altogether rule out injection of non-neutralized currents. In agreement with previous studies, we also find that magnetically isolated ARs remain globally current-balanced. In addition, we confirm and quantify the preference of a given magnetic polarity to follow a given sense of electric currents, indicating a dominant sense of twist in ARs. This coherence effect is more pronounced in more compact ARs with stronger PILs and must be of sub-photospheric origin. Our results yield a natural explanation of the Lorentz force, invariably generating velocity and magnetic shear along strong PILs, thus setting a physical context for the observed pre-eruption evolution in solar ARs.

  1. The effects of control-display gain on performance of race car drivers in an isometric braking task.

    Science.gov (United States)

    de Winter, J C F; de Groot, S

    2012-12-01

    To minimise lap times during car racing, it is important to build up brake forces rapidly and maintain precise control. We examined the effect of the amplification factor (gain) between brake pedal force and a visually represented output value on a driver's ability to track a target value. The test setup was a formula racing car cockpit fitted with an isometric brake pedal. Thirteen racing drivers performed tracking tasks with four control-display gains and two target functions: a step function (35 trials per gain) and a multisine function (15 trials per gain). The control-display gain had only minor effects on root mean-squared error between output value and target value, but it had large effects on build-up speed, overshoot, within-participants variability, and self-reported physical load. The results confirm the hypothesis that choosing an optimum gain involves balancing stability against physical effort.

  2. Screen time viewing behaviors and isometric trunk muscle strength in youth

    DEFF Research Database (Denmark)

    Grøntved, Anders; Ried-Larsen, Mathias; Froberg, Karsten

    2013-01-01

    The objective of this study was to examine the association of screen time viewing behavior with isometric trunk muscle strength in youth.......The objective of this study was to examine the association of screen time viewing behavior with isometric trunk muscle strength in youth....

  3. Strength Development: Using Functional Isometrics in an Isotonic Strength Training Program.

    Science.gov (United States)

    Jackson, Allen; And Others

    1985-01-01

    A study was made to determine if a combination of functional isometrics and standard isotonic training would be superior to a standard isotonic program in an instructional setting. The results provide support for functional isometrics as an enhancement where achievement of maximum strength is the goal. (Author/MT)

  4. Association Between Maximal Bench Press Strength and Isometric Handgrip Strength Among Breast Cancer Survivors.

    Science.gov (United States)

    Rogers, Benjamin H; Brown, Justin C; Gater, David R; Schmitz, Kathryn H

    2017-02-01

    To characterize the relationship between 1-repetition maximum (1-RM) bench press strength and isometric handgrip strength among breast cancer survivors. Cross-sectional study. Laboratory. Community-dwelling breast cancer survivors (N=295). Not applicable. 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer, with 3 maximal contractions of the left and right hands. All measures were conducted by staff with training in clinical exercise testing. Among 295 breast cancer survivors, 1-RM bench press strength was 18.2±6.1kg (range, 2.2-43.0kg), and isometric handgrip strength was 23.5±5.8kg (range, 9.0-43.0kg). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=.399; Pisometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7kg (95% limits of agreement, -8.2 to 17.6kg). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=.31; Pstrength (R 2 =.23). Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among breast cancer survivors. 1-RM bench press strength and isometric handgrip strength quantify distinct components of muscular strength. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Temperature dependence of the kinetics of isometric myocardium relaxation

    Energy Technology Data Exchange (ETDEWEB)

    Izakov, V.Ya.; Bykov, B.L.; Kimmelman, I.Ya.

    1981-11-01

    The dependence of the exponential decay constant expressing the isometric relaxation of the myocardium on temperature is investigated in animals with various specific contents of myocardial sarcoplasmic reticulum. Experiments were performed on cardiac ventricles and atria isolated from rabbits, frogs and turtles and electrically stimulated to produce maximal contraction at temperatures from 10 to 35 C. Arrhenius plots derived from the data are found to be linear in the myocardia of the rabbit and frog, with a greater activation energy for the relaxation found in the rabbit. The Arrhenius plot for the turtle, which has a sarcoplasmic reticulum content intermediate between those of the frog and rabbit, corresponds to two straight lines with different activation energies. Results thus support the hypothesis of two separate mechanisms of calcium removal, involving the sarcoplasmic reticulum and cellular membrane, in muscle relaxation.

  6. Acute effect of different stretching methods on isometric muscle strength

    Directory of Open Access Journals (Sweden)

    Gabriel Vasconcellos de Lima Costa e Silva

    2014-03-01

    This study investigated the acute effect of static stretching methods (SS and proprioceptive neuromuscular facilitation (PNF on the static muscle strength (SMS. Eleven young male subjects with strength training experience, performed 3 tests with a 48h interval between them, randomly selected, where each one subject carried out all procedures: a hand grip without stretching; b hand grip preceded by static stretching of wrist flexors muscles; c hand grip preceded by PNF stretching of wrist flexors muscles. The Shapiro-Wilk test verified the normality of data, and a one-way ANOVA with repeated measures, followed by Tukey’s post hoc test, evaluated the differences between the groups. The significance was set at p 0.05. In conclusion, both stretching methods had caused negative effects on isometric strength, reducing its levels.

  7. Fault diagnosis of rotating machine by isometric feature mapping

    International Nuclear Information System (INIS)

    Zhang, Yun; Li, Benwei; Wang, Lin; Wang, Wen; Wang, Zibin

    2013-01-01

    Principal component analysis (PCA) and linear discriminate analysis (LDA) are well-known linear dimensionality reductions for fault classification. However, since they are linear methods, they perform not well for high-dimensional data that has the nonlinear geometric structure. As kernel extension of PCA, Kernel PCA is used for nonlinear fault classification. However, the performance of Kernel PCA largely depends on its kernel function which can only be empirically selected from finite candidates. Thus, a novel rotating machine fault diagnosis approach based on geometrically motivated nonlinear dimensionality reduction named isometric feature mapping (Isomap) is proposed. The approach can effectively extract the intrinsic nonlinear manifold features embedded in high-dimensional fault data sets. Experimental results with rotor and rolling bearing data show that the proposed approach overcomes the flaw of conventional fault pattern recognition approaches and obviously improves the fault classification performance.

  8. Synchronization of muscular oscillations between two subjects during isometric interaction

    Directory of Open Access Journals (Sweden)

    Laura V. Schaefer

    2014-05-01

    Full Text Available Muscles oscillate with a frequency around 10 Hz. But what happens with myofascial oscillations, if two neuromuscular systems interact? The purpose of this study was to examine this question, initially, on the basis of a case study. Oscillations of the triceps brachii muscles of two subjects were determined through mechanomyography (MMG during isometric interaction. The MMG-signals were analyzed concerning the interaction of the two subjects with algorithms of nonlinear dynamics. In this case study it could be shown, that the muscles of both neuromuscular systems also oscillate with the known frequency (here 12 Hz during interaction. Furthermore, both subjects were able to adapt their oscillations against each other. This adjustment induced a significant ( < .05 coherent behavior, which was characterized by a phase shifting of approximately 90°. The authors draw the conclusion, that the complementary neuromuscular partners potentially have the ability of mutual synchronization.

  9. Acute Improvement of Vertical Jump Performance After Isometric Squats Depends on Knee Angle and Vertical Jumping Ability.

    Science.gov (United States)

    Tsoukos, Athanasios; Bogdanis, Gregory C; Terzis, Gerasimos; Veligekas, Panagiotis

    2016-08-01

    Tsoukos, A, Bogdanis, GC, Terzis, G, and Veligekas, P. Acute improvement of vertical jump performance after isometric squats depends on knee angle and vertical jumping ability. J Strength Cond Res 30(8): 2250-2257, 2016-This study examined the acute effects of maximum isometric squats at 2 different knee angles (90 or 140°) on countermovement jump (CMJ) performance in power athletes. Fourteen national-level male track and field power athletes completed 3 main trials (2 experimental and 1 control) in a randomized and counterbalanced order 1 week apart. Countermovement jump performance was evaluated using a force-plate before and 15 seconds, 3, 6, 9, and 12 minutes after 3 sets of 3 seconds maximum isometric contractions with 1-minute rest in between, from a squat position with knee angle set at 90 or 140°. Countermovement jump performance was improved compared with baseline only in the 140° condition by 3.8 ± 1.2% on the 12th minute of recovery (p = 0.027), whereas there was no change in CMJ height in the 90° condition. In the control condition, there was a decrease in CMJ performance over time, reaching -3.6 ± 1.2% (p = 0.049) after 12 minutes of recovery. To determine the possible effects of baseline jump performance on subsequent CMJ performance, subjects were divided into 2 groups ("high jumpers" and "low jumpers"). The baseline CMJ values of "high jumpers" and "low jumpers" differed significantly (CMJ: 45.1 ± 2.2 vs. 37.1 ± 3.9 cm, respectively, p = 0.001). Countermovement jump was increased only in the "high jumpers" group by 5.4 ± 1.4% (p = 0.001) and 7.4 ± 1.2% (p = 0.001) at the knee angles of 90 and 140°, respectively. This improvement was larger at the 140° angle (p = 0.049). Knee angle during isometric squats and vertical jumping ability are important determinants of the acute CMJ performance increase observed after a conditioning activity.

  10. An Isometric Mapping Based Co-Location Decision Tree Algorithm

    Science.gov (United States)

    Zhou, G.; Wei, J.; Zhou, X.; Zhang, R.; Huang, W.; Sha, H.; Chen, J.

    2018-05-01

    Decision tree (DT) induction has been widely used in different pattern classification. However, most traditional DTs have the disadvantage that they consider only non-spatial attributes (ie, spectral information) as a result of classifying pixels, which can result in objects being misclassified. Therefore, some researchers have proposed a co-location decision tree (Cl-DT) method, which combines co-location and decision tree to solve the above the above-mentioned traditional decision tree problems. Cl-DT overcomes the shortcomings of the existing DT algorithms, which create a node for each value of a given attribute, which has a higher accuracy than the existing decision tree approach. However, for non-linearly distributed data instances, the euclidean distance between instances does not reflect the true positional relationship between them. In order to overcome these shortcomings, this paper proposes an isometric mapping method based on Cl-DT (called, (Isomap-based Cl-DT), which is a method that combines heterogeneous and Cl-DT together. Because isometric mapping methods use geodetic distances instead of Euclidean distances between non-linearly distributed instances, the true distance between instances can be reflected. The experimental results and several comparative analyzes show that: (1) The extraction method of exposed carbonate rocks is of high accuracy. (2) The proposed method has many advantages, because the total number of nodes, the number of leaf nodes and the number of nodes are greatly reduced compared to Cl-DT. Therefore, the Isomap -based Cl-DT algorithm can construct a more accurate and faster decision tree.

  11. AN ISOMETRIC MAPPING BASED CO-LOCATION DECISION TREE ALGORITHM

    Directory of Open Access Journals (Sweden)

    G. Zhou

    2018-05-01

    Full Text Available Decision tree (DT induction has been widely used in different pattern classification. However, most traditional DTs have the disadvantage that they consider only non-spatial attributes (ie, spectral information as a result of classifying pixels, which can result in objects being misclassified. Therefore, some researchers have proposed a co-location decision tree (Cl-DT method, which combines co-location and decision tree to solve the above the above-mentioned traditional decision tree problems. Cl-DT overcomes the shortcomings of the existing DT algorithms, which create a node for each value of a given attribute, which has a higher accuracy than the existing decision tree approach. However, for non-linearly distributed data instances, the euclidean distance between instances does not reflect the true positional relationship between them. In order to overcome these shortcomings, this paper proposes an isometric mapping method based on Cl-DT (called, (Isomap-based Cl-DT, which is a method that combines heterogeneous and Cl-DT together. Because isometric mapping methods use geodetic distances instead of Euclidean distances between non-linearly distributed instances, the true distance between instances can be reflected. The experimental results and several comparative analyzes show that: (1 The extraction method of exposed carbonate rocks is of high accuracy. (2 The proposed method has many advantages, because the total number of nodes, the number of leaf nodes and the number of nodes are greatly reduced compared to Cl-DT. Therefore, the Isomap -based Cl-DT algorithm can construct a more accurate and faster decision tree.

  12. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n3p292   The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  13. Electromagnetic torques and forces due to misalignment effects and eddy currents in the homopolar generator, power supply for the Texas Experimental Tokamak (TEXT)

    International Nuclear Information System (INIS)

    Driga, M.D.; Bird, W.L.; Tolk, K.M.; Weldon, W.F.; Rylander, H.G.; Woodson, H.H.

    1977-01-01

    Asymmetries in the applied magnetic field due to manufacturing tolerances and rotor-stator misalignments can cause significant forces and moments in a homopolar generator. Parasitic eddy-currents in the rotor, brushes and bearings are also important effects of such asymmetries. The finite element method is used to calculate the magnetic flux distributions in the TEXT homopolar generators. The axial magnetic thrust force and the magnetic tilt moment acting on the rotor are calculated. Eddy-current torques opposing rotor motion are determined using the theory for eddy-current brakes. The results have been used in the design of the TEXT homopolar generator which have been proposed to provide the energy store and conversion for the toroidal field and ohmic heating coils of the new Texas Experimental Tokamak

  14. Design of a phased array for the generation of adaptive radiation force along a path surrounding a breast lesion for dynamic ultrasound elastography imaging.

    Science.gov (United States)

    Ekeom, Didace; Hadj Henni, Anis; Cloutier, Guy

    2013-03-01

    This work demonstrates, with numerical simulations, the potential of an octagonal probe for the generation of radiation forces in a set of points following a path surrounding a breast lesion in the context of dynamic ultrasound elastography imaging. Because of the in-going wave adaptive focusing strategy, the proposed method is adapted to induce shear wave fronts to interact optimally with complex lesions. Transducer elements were based on 1-3 piezocomposite material. Three-dimensional simulations combining the finite element method and boundary element method with periodic boundary conditions in the elevation direction were used to predict acoustic wave radiation in a targeted region of interest. The coupling factor of the piezocomposite material and the radiated power of the transducer were optimized. The transducer's electrical impedance was targeted to 50 Ω. The probe was simulated by assembling the designed transducer elements to build an octagonal phased-array with 256 elements on each edge (for a total of 2048 elements). The central frequency is 4.54 MHz; simulated transducer elements are able to deliver enough power and can generate the radiation force with a relatively low level of voltage excitation. Using dynamic transmitter beamforming techniques, the radiation force along a path and resulting acoustic pattern in the breast were simulated assuming a linear isotropic medium. Magnitude and orientation of the acoustic intensity (radiation force) at any point of a generation path could be controlled for the case of an example representing a heterogeneous medium with an embedded soft mechanical inclusion.

  15. Real-time muscle state estimation from EMG signals during isometric contractions using Kalman filters.

    Science.gov (United States)

    Menegaldo, Luciano L

    2017-12-01

    State-space control of myoelectric devices and real-time visualization of muscle forces in virtual rehabilitation require measuring or estimating muscle dynamic states: neuromuscular activation, tendon force and muscle length. This paper investigates whether regular (KF) and extended Kalman filters (eKF), derived directly from Hill-type muscle mechanics equations, can be used as real-time muscle state estimators for isometric contractions using raw electromyography signals (EMG) as the only available measurement. The estimators' amplitude error, computational cost, filtering lags and smoothness are compared with usual EMG-driven analysis, performed offline, by integrating the nonlinear Hill-type muscle model differential equations (offline simulations-OS). EMG activity of the three triceps surae components (soleus, gastrocnemius medialis and gastrocnemius lateralis), in three torque levels, was collected for ten subjects. The actualization interval (AI) between two updates of the KF and eKF was also varied. The results show that computational costs are significantly reduced (70x for KF and 17[Formula: see text] for eKF). The filtering lags presented sharp linear relationships with the AI (0-300 ms), depending on the state and activation level. Under maximum excitation, amplitude errors varied in the range 10-24% for activation, 5-8% for tendon force and 1.4-1.8% for muscle length, reducing linearly with the excitation level. Smoothness, measured by the ratio between the average standard variations of KF/eKF and OS estimations, was greatly reduced for activation but converged exponentially to 1 for the other states by increasing AI. Compared to regular KF, extended KF does not seem to improve estimation accuracy significantly. Depending on the particular application requirements, the most appropriate KF actualization interval can be selected.

  16. Electromyographic, cerebral and muscle hemodynamic responses during intermittent, isometric contractions of the biceps brachii at three submaximal intensities

    Directory of Open Access Journals (Sweden)

    Yagesh eBhambhani

    2014-06-01

    Full Text Available This study examined the electromyographic, cerebral and muscle hemodynamic responses during intermittent isometric contractions of biceps brachii at 20%, 40% and 60% of maximal voluntary contraction (MVC. Eleven volunteers completed two minutes of intermittent isometric contractions (12/min at an elbow angle of 90° interspersed with three minutes rest between intensities in systematic order. Surface electromyography (EMG was recorded from the right biceps brachii and near infrared spectroscopy (NIRS was used to simultaneously measure left prefrontal and right biceps brachii oxyhemoglobin (HbO2, deoxyhemoglobin (HHb and total hemoglobin (Hbtot. Transcranial Doppler ultrasound was used to measure middle cerebral artery velocity (MCAv bilaterally. Finger photoplethysmography was used to record beat-to-beat blood pressure and heart rate. EMG increased with force output from 20% to 60% MVC (P0.05. MCAv increased from rest to exercise but was not different among intensities (P>0.05. Force output correlated with the root mean square EMG and changes in muscle HbO2 (P0.05 at all three intensities. Force output declined by 8% from the 1st to the 24th contraction only at 60% MVC and was accompanied by systematic increases in RMS, cerebral HbO2 and Hbtot with a levelling off in muscle HbO2 and Hbtot. These changes were independent of alterations in mean arterial pressure. Since cerebral blood flow and oxygenation were elevated at 60% MVC, we attribute the development of fatigue to reduced muscle oxygen availability rather than impaired central n

  17. Real-time changes in corticospinal excitability related to motor imagery of a force control task

    DEFF Research Database (Denmark)

    Tatemoto, Tsuyoshi; Tsuchiya, Junko; Numata, Atsuki

    2017-01-01

    Objective To investigate real-time excitability changes in corticospinal pathways related to motor imagery in a changing force control task, using transcranial magnetic stimulation (TMS). Methods Ten healthy volunteers learnt to control the contractile force of isometric right wrist dorsiflexion...... in order to track an on-screen sine wave form. Participants performed the trained task 40 times with actual muscle contraction in order to construct the motor image. They were then instructed to execute the task without actual muscle contraction, but by imagining contraction of the right wrist...... in dorsiflexion. Motor evoked potentials (MEPs), induced by TMS in the right extensor carpi radialis muscle (ECR) and flexor carpi radialis muscle (FCR), were measured during motor imagery. MEPs were induced at five time points: prior to imagery, during the gradual generation of the imaged wrist dorsiflexion...

  18. Optimal selection of annulus radius ratio to enhance heat transfer with minimum entropy generation in developing laminar forced convection of water-Al2O3 nanofluid flow

    Institute of Scientific and Technical Information of China (English)

    Siavashi Majid; Jamali Mohammad

    2017-01-01

    Heat transfer and entropy generation of developing laminar forced convection flow of water-Al2O3 nanofluid in a concentric annulus with constant heat flux on the walls is investigated numerically. In order to determine entropy generation of fully developed flow, two approaches are employed and it is shown that only one of these methods can provide appropriate results for flow inside annuli. The effects of concentration of nanoparticles, Reynolds number and thermal boundaries on heat transfer enhancement and entropy generation of developing laminar flow inside annuli with different radius ratios and same cross sectional areas are studied. The results show that radius ratio is a very important decision parameter of an annular heat exchanger such that in each Re, there is an optimum radius ratio to maximize Nu and minimize entropy generation. Moreover, the effect of nanoparticles concentration on heat transfer enhancement and minimizing entropy generation is stronger at higher Reynolds.

  19. The effectiveness of FES-evoked EMG potentials to assess muscle force and fatigue in individuals with spinal cord injury.

    Science.gov (United States)

    Ibitoye, Morufu Olusola; Estigoni, Eduardo H; Hamzaid, Nur Azah; Wahab, Ahmad Khairi Abdul; Davis, Glen M

    2014-07-14

    The evoked electromyographic signal (eEMG) potential is the standard index used to monitor both electrical changes within the motor unit during muscular activity and the electrical patterns during evoked contraction. However, technical and physiological limitations often preclude the acquisition and analysis of the signal especially during functional electrical stimulation (FES)-evoked contractions. Hence, an accurate quantification of the relationship between the eEMG potential and FES-evoked muscle response remains elusive and continues to attract the attention of researchers due to its potential application in the fields of biomechanics, muscle physiology, and rehabilitation science. We conducted a systematic review to examine the effectiveness of eEMG potentials to assess muscle force and fatigue, particularly as a biofeedback descriptor of FES-evoked contractions in individuals with spinal cord injury. At the outset, 2867 citations were identified and, finally, fifty-nine trials met the inclusion criteria. Four hypotheses were proposed and evaluated to inform this review. The results showed that eEMG is effective at quantifying muscle force and fatigue during isometric contraction, but may not be effective during dynamic contractions including cycling and stepping. Positive correlation of up to r = 0.90 (p peak-to-peak amplitude of the eEMG and the decline in the force output during fatiguing isometric contractions has been reported. In the available prediction models, the performance index of the eEMG signal to estimate the generated muscle force ranged from 3.8% to 34% for 18 s to 70 s ahead of the actual muscle force generation. The strength and inherent limitations of the eEMG signal to assess muscle force and fatigue were evident from our findings with implications in clinical management of spinal cord injury (SCI) population.

  20. The Effectiveness of FES-Evoked EMG Potentials to Assess Muscle Force and Fatigue in Individuals with Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Morufu Olusola Ibitoye

    2014-07-01

    Full Text Available The evoked electromyographic signal (eEMG potential is the standard index used to monitor both electrical changes within the motor unit during muscular activity and the electrical patterns during evoked contraction. However, technical and physiological limitations often preclude the acquisition and analysis of the signal especially during functional electrical stimulation (FES-evoked contractions. Hence, an accurate quantification of the relationship between the eEMG potential and FES-evoked muscle response remains elusive and continues to attract the attention of researchers due to its potential application in the fields of biomechanics, muscle physiology, and rehabilitation science. We conducted a systematic review to examine the effectiveness of eEMG potentials to assess muscle force and fatigue, particularly as a biofeedback descriptor of FES-evoked contractions in individuals with spinal cord injury. At the outset, 2867 citations were identified and, finally, fifty-nine trials met the inclusion criteria. Four hypotheses were proposed and evaluated to inform this review. The results showed that eEMG is effective at quantifying muscle force and fatigue during isometric contraction, but may not be effective during dynamic contractions including cycling and stepping. Positive correlation of up to r = 0.90 (p < 0.05 between the decline in the peak-to-peak amplitude of the eEMG and the decline in the force output during fatiguing isometric contractions has been reported. In the available prediction models, the performance index of the eEMG signal to estimate the generated muscle force ranged from 3.8% to 34% for 18 s to 70 s ahead of the actual muscle force generation. The strength and inherent limitations of the eEMG signal to assess muscle force and fatigue were evident from our findings with implications in clinical management of spinal cord injury (SCI population.

  1. Manifestations of shoulder fatigue in prolonged activities involving low-force contractions

    NARCIS (Netherlands)

    Looze, M.P. de; Bosch, T.; Dieën, J. van

    2009-01-01

    Shoulder fatigue has been suggested to be a useful risk indicator for shoulder disorders in repetitive, low-force work tasks. In contrast to high-force or purely isometric tasks, it is unclear whether measurable fatigue develops in realistic low-force work. The question addressed in this review was:

  2. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  3. Dynamic balance ability in young elite soccer players: implication of isometric strength.

    Science.gov (United States)

    Chtara, Moktar; Rouissi, Mehdi; Bragazzi, Nicola L; Owen, Adam L; Haddad, Monoem; Chamari, Karim

    2018-04-01

    Soccer requires maintaining unilateral balance when executing movement with the contralateral leg. Despite the fact that balance requires standing with maintaining isometric posture with the support leg, currently there is a lack of studies regarding the implication of isometric strength on dynamic balance's performance among young soccer players. Therefore, the aim of this study was to examine the relationship between the Y-Balance Test and 12 lower limbs isometric strength tests. Twenty-six right footed soccer players (mean±SD, age=16.2±1.6 years, height=175±4.2 cm, body mass=68.8±6.1 kg) performed a dynamic balance test (star excursion balance-test with dominant- (DL) and nondominant-legs (NDL). Furthermore, maximal isometric contraction tests of 12 lower limb muscle groups were assessed in DL and NDL. Correlations analysis reported a significant positive relationship between some of isometric strength tests (with DL and NDL) and the Y-Balance Test. Furthermore, stepwise multiple regression analysis showed that maximal isometric strength explained between 21.9% and 49.4% of the variance of the Y-Balance Test. Moreover, maximal isometric strength was dependent upon the reaching angle of the Y-Balance Test and the leg used to support body weight. This study showed a significant implication of maximal isometric strength of the lower limb and the Y-Balance Test. Moreover, the present investigation suggests the implementation of specific lower limb strengthening exercises depending on players' deficit in each reaching direction and leg. This result suggests that further studies should experiment if increasing lower limbs isometric strength could improve dynamic balance ability among young soccer players.

  4. The Association between Maximal Bench Press Strength and Isometric Handgrip Strength among Breast Cancer Survivors

    Science.gov (United States)

    Rogers, Benjamin H.; Brown, Justin C.; Gater, David R.; Schmitz, Kathryn H.

    2016-01-01

    Objective One-repetition maximum (1-RM) bench press strength is considered the gold standard to quantify upper-body muscular strength. Isometric handgrip strength is frequently used as a surrogate for 1-RM bench press strength among breast cancer (BrCa) survivors. The relationship between 1-RM bench press strength and isometric handgrip strength, however, has not been characterized among BrCa survivors. Design Cross-sectional study. Setting Laboratory. Participants Community-dwelling BrCa survivors. Interventions Not applicable. Main Outcome Measure 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer with three maximal contractions of left and right hands. All measures were conducted by staff with training in clinical exercise testing. Results Among 295 BrCa survivors, 1-RM bench press strength was 18.2±6.1 kg (range: 2.2-43.0) and isometric handgrip strength was 23.5±5.8 kg (range: 9.0-43.0). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=0.399; Pisometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7 kg (95% limits of agreement: −8.2 to 17.6). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=0.31; Pstrength (R2=0.23). Conclusions Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among BrCa survivors. 1-RM bench press and isometric handgrip strength quantify distinct components of muscular strength. PMID:27543047

  5. The effects of cutting parameters on cutting forces and heat generation when drilling animal bone and biomechanical test materials.

    Science.gov (United States)

    Cseke, Akos; Heinemann, Robert

    2018-01-01

    The research presented in this paper investigated the effects of spindle speed and feed rate on the resultant cutting forces (thrust force and torque) and temperatures while drilling SawBones ® biomechanical test materials and cadaveric cortical bone (bovine and porcine femur) specimens. It also investigated cortical bone anisotropy on the cutting forces, when drilling in axial and radial directions. The cutting forces are only affected by the feed rate, whereas the cutting temperature in contrast is affected by both spindle speed and feed rate. The temperature distribution indicates friction as the primary heat source, which is caused by the rubbing of the tool margins and the already cut chips over the borehole wall. Cutting forces were considerably higher when drilling animal cortical bone, in comparison to cortical test material. Drilling direction, and therewith anisotropy, appears to have a negligible effect on the cutting forces. The results suggest that this can be attributed to the osteons being cut at an angle rather than in purely axial or radial direction, as a result of a twist drill's point angle. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Muscle architecture and fibre characteristics of rat gastrocnemius and semimembranosus muscles during isometric contractions.

    Science.gov (United States)

    Huijing, P A; van Lookeren Campagne, A A; Koper, J F

    1989-01-01

    Rat gastrocnemius medialis (GM) and semimembranosus (SM) muscles have a very different morphology. GM is a very pennate muscle, combining relatively short muscle fibre length with sizable fibre angles and long muscle and aponeurosis lengths. SM is a more parallel-fibred muscle, combining a relatively long fibre length with a small fibre angle and short aponeurosis length. The mechanisms of fibre shortening as well as angle increase are operational in GM as well as SM. However, as a consequence of isometric contraction, changes of fibre length and angle are greater for GM than for SM at any relative muscle length. These differences are particularly notable at short muscle lengths: at 80% of optimum muscle length, fibre length changes of approximately 30% are coupled to fibre angle changes of 15 degrees in GM, while for SM these changes are 4% and 0.6 degrees, respectively. A considerable difference was found for normalized active slack muscle length (GM approximately 80 and SM approximately 45%). This is explained by differences of degree of pennation as well as factors related to differences found for estimated fibre length-force characteristics. Estimated normalized active fibre slack length was considerably smaller for SM than for GM (approximately 40 and 60%, respectively). The most likely explanation of these findings are differences of distribution of optimum fibre lengths, possibly in combination with differences of myofilament lengths and/or fibre length distributions.

  7. Isometric Mid-Thigh Pull Performance Is Associated With Athletic Performance And Sprinting Kinetics In Division I Men And Women's Basketball Players.

    Science.gov (United States)

    Townsend, Jeremy R; Bender, David; Vantrease, William; Hudy, John; Huet, Kevin; Williamson, Cassie; Bechke, Emily; Serafini, Paul; Mangine, Gerald T

    2017-07-31

    To examine the relationships between isometric mid-thigh pull (IMTP) force, athletic performance measures, and sprint kinetics in Division I men's and women's basketball players. Twenty-three (male = 8, female = 15) division 1 basketball players completed a maximal 20-m sprint trial while tethered to a device which provided kinetic feedback (peak and average sprinting power, velocity and force). Additionally, one repetition-maximal (1RM) front squat, 1RM hang clean, vertical jump height, and agility (pro-agility and lane agility) tests were performed. Rate of force development (RFD) at 50ms, 100ms, 150ms, 200ms and 250ms of IMTP, as well as peak force (PF) were also collected. Pearson product-moment correlation analysis was used to examine the relationships between these measures. Significant (p training.

  8. Dissipative particle dynamics simulation of flow generated by two rotating concentric cylinders: II. Lateral dissipative and random forces

    International Nuclear Information System (INIS)

    Filipovic, N; Haber, S; Kojic, M; Tsuda, A

    2008-01-01

    Traditional DPD methods address dissipative and random forces exerted along the line connecting neighbouring particles. Espanol (1998 Phys. Rev. E 57 2930-48) suggested adding dissipative and random force components in a direction perpendicular to this line. This paper focuses on the advantages and disadvantages of such an addition as compared with the traditional DPD method. Our benchmark system comprises fluid initially at rest occupying the space between two concentric cylinders rotating with various angular velocities. The effect of the lateral force components on the time evolution of the simulated velocity profile was also compared with that of the known analytical solution. The results show that (i) the solution accuracy at steady state has improved and the error has been reduced by at least 30% (in one case by 75%), (ii) the DPD time to reach steady state has been halved, (iii) the CPU time has increased by only 30%, and (iv) no significant differences exist in density and temperature distributions

  9. Proceedings of the Conference on Computer Generated Forces and Behavioral Representation (6th), Held in Orlando, Florida, on 23-25 July 1996

    Science.gov (United States)

    1996-07-01

    minimizing the staffing requirements of such exercises by replac- ing as many, purely ancillary, staff by computer- generated forces (CGFs) is...autonomously, if they are to be of any real value in reducing staffing requirements in synthetic en- vironments. Yet in order to adapt reliably to vari...used which is offset and rotated from GCC, Geocentric Cartesian Coordinates. The resulting frame of reference has its origin at the center of the

  10. Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses.

    Science.gov (United States)

    Krueger, Eddy; Popović-Maneski, Lana; Nohama, Percy

    2018-02-01

    A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord-injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on

  11. GENDER DIFFERENCES IN THE CARDIOVASCULAR AUTONOMIC RESPONSE DURING ISOMETRIC HANDGRIP EXERCISE

    Directory of Open Access Journals (Sweden)

    Rajasekhar

    2015-09-01

    Full Text Available Physical exercise can be regarded as a period of increased sympathetic activity with simultaneous parasympathetic withdrawal. Many circulatory changes occur during exercise due to mass sympathetic discharge. The exercise cap acity among gender may differ due to substantial anatomical, physiological, and morphological differences. AIMS & OBJECTIVES: To evaluate the gender difference in the cardiovascular response during isometric hand grip exercise. MATERIALS AND METHOD S: 30 healthy young adult male & 30 female students aged between 18 - 24 years who had no prior endurance training were asked to perform Isometric handgrip contractions using an isometric handgrip apparatus. The heart rate was calculated using BIOPAC MP30. Blood p ressure measurements were obtained using a sphygmomanometer. RESULTS & CONCLUSION: The results of the present study showed significant increase in the blood pressure values in men during isometric exercise compared to women which may be because of increase d catecholamine release to acute stress among men

  12. Descending pain modulation and its interaction with peripheral sensitization following sustained isometric muscle contraction in fibromyalgia

    DEFF Research Database (Denmark)

    Ge, H-Y; Nie, Hongling; Graven-Nielsen, Thomas

    2012-01-01

    OBJECTIVE: Sustained isometric muscle contraction (fatiguing contraction) recruits segmental and/or extrasegmental descending inhibition in healthy subjects but not in fibromyalgia (FM). We hypothesized that fatiguing contraction may shift descending pain modulation from inhibition towards...

  13. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  14. Time to failure and neuromuscular response to intermittent isometric exercise at different levels of vascular occlusion: a randomized crossover study

    Directory of Open Access Journals (Sweden)

    Mikhail Santos Cerqueira

    2017-04-01

    Full Text Available Objectives: The purpose this study was investigate the effects of different vascular occlusion levels (total occlusion (TO, partial occlusion (PO or free flow (FF during intermittent isometric handgrip exercise (IIHE on the time to failure (TF and the recovery of the maximum voluntary isometric force (MVIF, median frequency (EMGFmed and peak of EMG signal (EMGpeak after failure.  Methods: Thirteen healthy men (21 ± 1.71 year carried out an IIHE until the failure at 45% of MVIF with TO, PO or FF. Occlusion pressure was determined previously to the exercise. The MVIF, EMGFmed and EMGpeak were measured before and after exercise. Results: TF (in seconds was significantly different (p < 0.05 among all investigated conditions: TO (150 ± 68, PO (390 ± 210 and FF (510 ± 240. The MVIF was lower immediately after IIHE, remaining lower eleven minutes after failure in all cases (p <0.05, when compared to pre exercise. There was a greater force reduction (p <0.05 one minute after the failure in the PO (-45.8% and FF (-39.9% conditions, when compared to TO (-28.1%. Only the PO condition caused lower MVIF (p <0.05 than in the OT, eleven minutes after the task failure. PO caused a greater reduction in EMGFmed compared TO and greater increase in EMGpeak, when compared to TO and FF (p <0.05. Conclusions: TO during IIHE lead to a lower time to failure, but a faster MVIF recovery, while the PO seems to be associated to a slower neuromuscular recovery, when compared to other conditions.

  15. Up-regulation of Rho/ROCK signaling in sarcoma cells drives invasion and increased generation of protrusive forces

    Czech Academy of Sciences Publication Activity Database

    Rosel, D.; Brabek, J.; Tolde, O.; Mierke, C.T.; Zitterbart, D.P.; Raupach, C.; Bicanova, K.; Kollmannsberger, P.; Pánková, D.; Veselý, Pavel; Folk, P.; Fabry, B.

    2008-01-01

    Roč. 6, č. 9 (2008), s. 1410-1420 ISSN 1541-7786 Institutional research plan: CEZ:AV0Z50520514 Keywords : Rho kinase ROCK * traction force microscopy * ameboid invasion Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.533, year: 2008

  16. Exact solutions for isometric embeddings of pseudo-Riemannian manifolds

    International Nuclear Information System (INIS)

    Amery, G; Moodley, J

    2014-01-01

    Embeddings into higher dimensions are of direct importance in the study of higher dimensional theories of our Universe, in high energy physics and in classical general relativity. Theorems have been established that guarantee the existence of local and global codimension-1 embeddings between pseudo-Riemannian manifolds, particularly for Einstein embedding spaces. A technique has been provided to determine solutions to such embeddings. However, general solutions have not yet been found and most known explicit solutions are for embedded spaces with relatively simple Ricci curvature. Motivated by this, we have considered isometric embeddings of 4-dimensional pseudo-Riemannian spacetimes into 5-dimensional Einstein manifolds. We have applied the technique to treat specific 4-dimensional cases of interest in astrophysics and cosmology (including the global monopole exterior and Vaidya-de Sitter-class solutions), and provided novel physical insights into, for example, Einstein-Gauss-Bonnet gravity. Since difficulties arise in solving the 5-dimensional equations for given 4-dimensional spaces, we have also investigated embedded spaces, which admit bulks with a particular metric form. These analyses help to provide insight to the general embedding problem

  17. Screen time viewing behaviors and isometric trunk muscle strength in youth.

    Science.gov (United States)

    Grøntved, Anders; Ried-Larsen, Mathias; Froberg, Karsten; Wedderkopp, Niels; Brage, Søren; Kristensen, Peter Lund; Andersen, Lars Bo; Møller, Niels Christian

    2013-10-01

    The objective of this study was to examine the association of screen time viewing behavior with isometric trunk muscle strength in youth. A cross-sectional study was carried out including 606 adolescents (14-16 yr old) participating in the Danish European Youth Heart Study, a population-based study with assessments conducted in either 1997/1998 or 2003/2004. Maximal voluntary contractions during isometric back extension and abdominal flexion were determined using a strain gauge dynamometer, and cardiorespiratory fitness (CRF) was obtained using a maximal cycle ergometer test. TV viewing time, computer use, and other lifestyle behaviors were obtained by self-report. Analyses of association of screen use behaviors with isometric trunk muscle strength were carried out using multivariable adjusted linear regression. The mean (SD) isometric strength was 0.87 (0.16) N·kg-1. TV viewing, computer use, and total screen time use were inversely associated with isometric trunk muscle strength in analyses adjusted for lifestyle and sociodemographic factors. After further adjustment for CRF and waist circumference, associations remained significant for computer use and total screen time, but TV viewing was only marginally associated with muscle strength after these additional adjustments (-0.05 SD (95% confidence interval, -0.11 to 0.005) difference in strength per 1 h·d-1 difference in TV viewing time, P = 0.08). Each 1 h·d-1 difference in total screen time use was associated with -0.09 SD (95% confidence interval, -0.14 to -0.04) lower isometric trunk muscle strength in the fully adjusted model (P = 0.001). There were no indications that the association of screen time use with isometric trunk muscle strength was attenuated among highly fit individuals (P = 0.91 for CRF by screen time interaction). Screen time use was inversely associated with isometric trunk muscle strength independent of CRF and other confounding factors.

  18. New generation of docking programs: Supercomputer validation of force fields and quantum-chemical methods for docking.

    Science.gov (United States)

    Sulimov, Alexey V; Kutov, Danil C; Katkova, Ekaterina V; Ilin, Ivan S; Sulimov, Vladimir B

    2017-11-01

    Discovery of new inhibitors of the protein associated with a given disease is the initial and most important stage of the whole process of the rational development of new pharmaceutical substances. New inhibitors block the active site of the target protein and the disease is cured. Computer-aided molecular modeling can considerably increase effectiveness of new inhibitors development. Reliable predictions of the target protein inhibition by a small molecule, ligand, is defined by the accuracy of docking programs. Such programs position a ligand in the target protein and estimate the protein-ligand binding energy. Positioning accuracy of modern docking programs is satisfactory. However, the accuracy of binding energy calculations is too low to predict good inhibitors. For effective application of docking programs to new inhibitors development the accuracy of binding energy calculations should be higher than 1kcal/mol. Reasons of limited accuracy of modern docking programs are discussed. One of the most important aspects limiting this accuracy is imperfection of protein-ligand energy calculations. Results of supercomputer validation of several force fields and quantum-chemical methods for docking are presented. The validation was performed by quasi-docking as follows. First, the low energy minima spectra of 16 protein-ligand complexes were found by exhaustive minima search in the MMFF94 force field. Second, energies of the lowest 8192 minima are recalculated with CHARMM force field and PM6-D3H4X and PM7 quantum-chemical methods for each complex. The analysis of minima energies reveals the docking positioning accuracies of the PM7 and PM6-D3H4X quantum-chemical methods and the CHARMM force field are close to one another and they are better than the positioning accuracy of the MMFF94 force field. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Changes in motor unit recruitment strategy during pain alters force direction.

    Science.gov (United States)

    Tucker, Kylie J; Hodges, Paul W

    2010-10-01

    Motor unit (MU) recruitment is altered (decreased discharge rate and cessation of discharge in some units, and recruitment of new units) in force-matched contractions during pain compared to contractions performed before pain. As MU's within a motoneurone pool have different force direction properties we hypothesised that altered MU recruitment during experimental knee pain would change the force vector (total force (F(T)): amplitude and angle) generated by the quadriceps. Force was produced at two levels during 1 × 60-s and 3 × 10-s isometric contractions of knee extensors, and recorded by two force transducers at right angles. This enabled calculation of both F(E) (extension force) and F(T). MU recruitment was recorded from the medial and lateral vastii with four fine-wire electrodes. Pain was induced by hypertonic saline injection in the infra-patella fat pad. Nine subjects matched F(E) and six subjects also matched both medial and lateral forces (F(T)) before and during pain. Changes in MU discharge pattern (decreased discharge rate (Precruitment of new units) during pain were associated with a ∼5° change in absolute force angle. As force angle changed in both directions (left/right) for individual subjects with pain there was no change in average F(T) amplitude between conditions. When both medial and lateral forces were matched MU discharge rate decreased (Punits ceased firing or were newly recruited during pain. Change in motoneurone recruitment during pain alters direction of muscle force. This may be a strategy to avoid pain or protect the painful part. Copyright © 2010 European Federation of International Association for the Study of Pain Chapters. Published by Elsevier Ltd. All rights reserved.

  20. Feeding biomechanics and theoretical calculations of bite force in bull sharks (Carcharhinus leucas) during ontogeny.

    Science.gov (United States)

    Habegger, Maria L; Motta, Philip J; Huber, Daniel R; Dean, Mason N

    2012-12-01

    Evaluations of bite force, either measured directly or calculated theoretically, have been used to investigate the maximum feeding performance of a wide variety of vertebrates. However, bite force studies of fishes have focused primarily on small species due to the intractable nature of large apex predators. More massive muscles can generate higher forces and many of these fishes attain immense sizes; it is unclear how much of their biting performance is driven purely by dramatic ontogenetic increases in body size versus size-specific selection for enhanced feeding performance. In this study, we investigated biting performance and feeding biomechanics of immature and mature individuals from an ontogenetic series of an apex predator, the bull shark, Carcharhinus leucas (73-285cm total length). Theoretical bite force ranged from 36 to 2128N at the most anterior bite point, and 170 to 5914N at the most posterior bite point over the ontogenetic series. Scaling patterns differed among the two age groups investigated; immature bull shark bite force scaled with positive allometry, whereas adult bite force scaled isometrically. When the bite force of C. leucas was compared to those of 12 other cartilaginous fishes, bull sharks presented the highest mass-specific bite force, greater than that of the white shark or the great hammerhead shark. A phylogenetic independent contrast analysis of anatomical and dietary variables as determinants of bite force in these 13 species indicated that the evolution of large adult bite forces in cartilaginous fishes is linked predominantly to the evolution of large body size. Multiple regressions based on mass-specific standardized contrasts suggest that the evolution of high bite forces in Chondrichthyes is further correlated with hypertrophication of the jaw adductors, increased leverage for anterior biting, and widening of the head. Lastly, we discuss the ecological significance of positive allometry in bite force as a possible

  1. Force-independent distribution of correlated neural inputs to hand muscles during three-digit grasping.

    Science.gov (United States)

    Poston, Brach; Danna-Dos Santos, Alessander; Jesunathadas, Mark; Hamm, Thomas M; Santello, Marco

    2010-08-01

    The ability to modulate digit forces during grasping relies on the coordination of multiple hand muscles. Because many muscles innervate each digit, the CNS can potentially choose from a large number of muscle coordination patterns to generate a given digit force. Studies of single-digit force production tasks have revealed that the electromyographic (EMG) activity scales uniformly across all muscles as a function of digit force. However, the extent to which this finding applies to the coordination of forces across multiple digits is unknown. We addressed this question by asking subjects (n = 8) to exert isometric forces using a three-digit grip (thumb, index, and middle fingers) that allowed for the quantification of hand muscle coordination within and across digits as a function of grasp force (5, 20, 40, 60, and 80% maximal voluntary force). We recorded EMG from 12 muscles (6 extrinsic and 6 intrinsic) of the three digits. Hand muscle coordination patterns were quantified in the amplitude and frequency domains (EMG-EMG coherence). EMG amplitude scaled uniformly across all hand muscles as a function of grasp force (muscle x force interaction: P = 0.997; cosines of angle between muscle activation pattern vector pairs: 0.897-0.997). Similarly, EMG-EMG coherence was not significantly affected by force (P = 0.324). However, coherence was stronger across extrinsic than that across intrinsic muscle pairs (P = 0.0039). These findings indicate that the distribution of neural drive to multiple hand muscles is force independent and may reflect the anatomical properties or functional roles of hand muscle groups.

  2. Relationship between lower extremity isometric muscle strength and standing balance in patients with multiple sclerosis.

    Science.gov (United States)

    Citaker, Seyit; Guclu-Gunduz, Arzu; Yazici, Gokhan; Bayraktar, Deniz; Nazliel, Bijen; Irkec, Ceyla

    2013-01-01

    Muscle strength and standing balance decrease in patients with Multiple Sclerosis (MS). The aim of the present study was to investigate the relationship between the lower extremity isometric muscle strength and standing balance in patients with MS. Forty-seven patients with MS and 10 healthy volunteers were included. Neurological disability level was assessed using Expanded Disability Status Scale (EDSS). Isometric strength of seven lower extremity muscles (hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor) was assessed using hand-held dynamometer. Duration of static one-leg standing balance was measured using digital chronometer. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength, and duration of one-leg standing balance were decreased in patients with MS when compared with controls (p isometric muscle strength and EDSS level was related duration of one-leg standing balance in patients with MS. All assessed lower extremity isometric muscle strength (except ankle dorsal flexor) was related with EDSS. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength decreases in ambulatory MS patients. Lower extremity muscle weakness and neurological disability level are related with imbalance in MS population. Hip and knee region muscles weakness increases the neurological disability level. For the better balance and decrease neurological disability level whole lower extremity muscle strengthening should be included in rehabilitation programs.

  3. [Evaluation of isometric force in lower limbs and body composition in preterm infants].

    Science.gov (United States)

    Mata Zubillaga, D; Rodríguez Fernández, C; Rodríguez Fernández, L M; de Paz Fernández, J A; Arboleda Franco, S; Alonso Patiño, F

    2015-10-01

    Strength is a physical quality with a clear influence on quality of life. It is determined by the structure of the musculoskeletal system, and depends on the muscular structure. It has been described that prematurity conditions both qualities. The aims of this study are to determine whether prematurity is associated with strength or body composition and evaluate the relationship between prematurity, strength and muscle mass. Case-control study. Participants were premature 7-to-11 year-old children and full-term birth controls. Strength was measured by a strength gauge and body composition from DEXA (duel-energy X-ray absorptiometry) scans. A total of 89 subjects were included and divided into three groups: 30 prematures with birth-weight ≤ 1500g, 29 prematures with birth-weight 1500-2000g, and 30 controls. Weight and BMI z-score was lower in the premature group. No differences were found in muscular mass or strength between groups. A ratio was established between strength and weight or muscular mass. It was observed that it was possible for them to move four times their weight, without finding any differences between groups or a relationship with birth-weight. Between 7 and 11 years of age, children who were premature have lower weight and BMI than the rest of the children. However, there were no differences in body composition or strength between preterm children and controls. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  4. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets.

    Science.gov (United States)

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore de

    2016-01-01

    The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (pbrackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  5. Isometric Mid-Thigh Pull Correlates With Strength, Sprint, and Agility Performance in Collegiate Rugby Union Players.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Tanigawa, Satoru; Miramonti, Amelia A; La Monica, Michael B; Beyer, Kyle S; Church, David D; Fukuda, David H; Stout, Jeffrey R

    2016-11-01

    Wang, R, Hoffman, JR, Tanigawa, S, Miramonti, AA, La Monica, MB, Beyer, KS, Church, DD, Fukuda, DH, and Stout, JR. Isometric mid-thigh pull correlates with strength, sprint, and agility performance in collegiate rugby union players. J Strength Cond Res 30(11): 3051-3056, 2016-The purpose of this investigation was to examine the relationships between isometric mid-thigh pull (IMTP) force and strength, sprint, and agility performance in collegiate rugby union players. Fifteen members of a champion-level university's club rugby union team (mean ± SD: 20.67 ± 1.23 years, 1.78 ± 0.06 m, and 86.51 ± 14.18 kg) participated in this investigation. One repetition maximum (1RM) squat, IMTP, speed (40 m sprint), and agility (proagility test and T-test) were performed during 3 separate testing sessions. Rate of force development (RFD) and force output at 30, 50, 90, 100, 150, 200, and 250 milliseconds of IMTP, as well as the peak value were determined. Pearson product-moment correlation analysis was used to examine the relationships between these measures. Performance in the 1RM squat was significantly correlated to the RFD between 90 and 250 milliseconds from the start of contraction (r's ranging from 0.595 to 0.748), and peak force (r = 0.866, p ≤ 0.05). One repetition maximum squat was also correlated to force outputs between 90 and 250 milliseconds (r's ranging from 0.757 to 0.816, p ≤ 0.05). Sprint time over the first 5 m in the 40 m sprint was significantly (p ≤ 0.05) correlated with peak RFD (r = -0.539) and RFD between 30 and 50 milliseconds (r's = -0.570 and -0.527, respectively). Time for the proagility test was correlated with peak RFD (r = -0.523, p ≤ 0.05) and RFD between 30 and 100 milliseconds (r's ranging from -0.518 to -0.528, p's strength, agility, and sprint performance. Future studies should examine IMTP as a potential tool to monitor athletic performance during the daily training of rugby union players.

  6. Real-time changes in corticospinal excitability related to motor imagery of a force control task.

    Science.gov (United States)

    Tatemoto, Tsuyoshi; Tsuchiya, Junko; Numata, Atsuki; Osawa, Ryuji; Yamaguchi, Tomofumi; Tanabe, Shigeo; Kondo, Kunitsugu; Otaka, Yohei; Sugawara, Kenichi

    2017-09-29

    To investigate real-time excitability changes in corticospinal pathways related to motor imagery in a changing force control task, using transcranial magnetic stimulation (TMS). Ten healthy volunteers learnt to control the contractile force of isometric right wrist dorsiflexion in order to track an on-screen sine wave form. Participants performed the trained task 40 times with actual muscle contraction in order to construct the motor image. They were then instructed to execute the task without actual muscle contraction, but by imagining contraction of the right wrist in dorsiflexion. Motor evoked potentials (MEPs), induced by TMS in the right extensor carpi radialis muscle (ECR) and flexor carpi radialis muscle (FCR), were measured during motor imagery. MEPs were induced at five time points: prior to imagery, during the gradual generation of the imaged wrist dorsiflexion (Increasing phase), the peak value of the sine wave, during the gradual reduction (Decreasing phase), and after completion of the task. The MEP ratio, as the ratio of imaged MEPs to resting-state, was compared between pre- and post-training at each time point. In the ECR muscle, the MEP ratio significantly increased during the Increasing phase and at the peak force of dorsiflexion imagery after training. Moreover, the MEP ratio was significantly greater in the Increasing phase than in the Decreasing phase. In the FCR, there were no significant consistent changes. Corticospinal excitability during motor imagery in an isometric contraction task was modulated in relation to the phase of force control after image construction. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Changes in power and force generation during coupled eccentric-concentric versus concentric muscle contraction with training and aging

    DEFF Research Database (Denmark)

    Caserotti, Paolo; Aagaard, Per; Puggaard, Lis

    2008-01-01

    Age-related decline in maximal concentric muscle power is associated with frailty and functional impairments in the elderly. Compared to concentric contraction, mechanical muscle output is generally enhanced when muscles are rapidly pre-stretched (eccentric contraction), albeit less pronounced...... with increasing age. Exercise has been recommended to prevent loss of muscle power and function and recent guidelines indicate training program for increasing muscle power highly relevant for elderly subjects. This study examined the differences in muscle power, force and movement pattern during concentric......) and JH increased in training group (P age-related decline in muscle power and functional performance observed in the control subjects, while substantial gains...

  8. Isometric and isokinetic hip strength and agonist/antagonist ratios in symptomatic femoroacetabular impingement.

    Science.gov (United States)

    Diamond, Laura E; Wrigley, Tim V; Hinman, Rana S; Hodges, Paul W; O'Donnell, John; Takla, Amir; Bennell, Kim L

    2016-09-01

    This study investigated isometric and isokinetic hip strength in individuals with and without symptomatic femoroacetabular impingement (FAI). The specific aims were to: (i) determine whether differences exist in isometric and isokinetic hip strength measures between groups; (ii) compare hip strength agonist/antagonist ratios between groups; and (iii) examine relationships between hip strength and self-reported measures of either hip pain or function in those with FAI. Cross-sectional. Fifteen individuals (11 males; 25±5 years) with symptomatic FAI (clinical examination and imaging (alpha angle >55° (cam FAI), and lateral centre edge angle >39° and/or positive crossover sign (combined FAI))) and 14 age- and sex-matched disease-free controls (no morphological FAI on magnetic resonance imaging) underwent strength testing. Maximal voluntary isometric contraction strength of hip muscle groups and isokinetic hip internal (IR) and external rotation (ER) strength (20°/s) were measured. Groups were compared with independent t-tests and Mann-Whitney U tests. Participants with FAI had 20% lower isometric abduction strength than controls (p=0.04). There were no significant differences in isometric strength for other muscle groups or peak isokinetic ER or IR strength. The ratio of isometric, but not isokinetic, ER/IR strength was significantly higher in the FAI group (p=0.01). There were no differences in ratios for other muscle groups. Angle of peak IR torque was the only feature correlated with symptoms. Individuals with symptomatic FAI demonstrate isometric hip abductor muscle weakness and strength imbalance in the hip rotators. Strength measurement, including agonist/antagonist ratios, may be relevant for clinical management of FAI. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Corticomuscular synchronization with small and large dynamic force output

    Science.gov (United States)

    Andrykiewicz, Agnieszka; Patino, Luis; Naranjo, Jose Raul; Witte, Matthias; Hepp-Reymond, Marie-Claude; Kristeva, Rumyana

    2007-01-01

    Background Over the last few years much research has been devoted to investigating the synchronization between cortical motor and muscular activity as measured by EEG/MEG-EMG coherence. The main focus so far has been on corticomuscular coherence (CMC) during static force condition, for which coherence in beta-range has been described. In contrast, we showed in a recent study [1] that dynamic force condition is accompanied by gamma-range CMC. The modulation of the CMC by various dynamic force amplitudes, however, remained uninvestigated. The present study addresses this question. We examined eight healthy human subjects. EEG and surface EMG were recorded simultaneously. The visuomotor task consisted in isometric compensation for 3 forces (static, small and large dynamic) generated by a manipulandum. The CMC, the cortical EEG spectral power (SP), the EMG SP and the errors in motor performance (as the difference between target and exerted force) were analyzed. Results For the static force condition we found the well-documented, significant beta-range CMC (15–30 Hz) over the contralateral sensorimotor cortex. Gamma-band CMC (30–45 Hz) occurred in both small and large dynamic force conditions without any significant difference between both conditions. Although in some subjects beta-range CMC was observed during both dynamic force conditions no significant difference between conditions could be detected. With respect to the motor performance, the lowest errors were obtained in the static force condition and the highest ones in the dynamic condition with large amplitude. However, when we normalized the magnitude of the errors to the amplitude of the applied force (relative errors) no significant difference between both dynamic conditions was observed. Conclusion These findings confirm that during dynamic force output the corticomuscular network oscillates at gamma frequencies. Moreover, we show that amplitude modulation of dynamic force has no effect on the gamma CMC

  10. Corticomuscular synchronization with small and large dynamic force output

    Directory of Open Access Journals (Sweden)

    Witte Matthias

    2007-11-01

    Full Text Available Abstract Background Over the last few years much research has been devoted to investigating the synchronization between cortical motor and muscular activity as measured by EEG/MEG-EMG coherence. The main focus so far has been on corticomuscular coherence (CMC during static force condition, for which coherence in beta-range has been described. In contrast, we showed in a recent study 1 that dynamic force condition is accompanied by gamma-range CMC. The modulation of the CMC by various dynamic force amplitudes, however, remained uninvestigated. The present study addresses this question. We examined eight healthy human subjects. EEG and surface EMG were recorded simultaneously. The visuomotor task consisted in isometric compensation for 3 forces (static, small and large dynamic generated by a manipulandum. The CMC, the cortical EEG spectral power (SP, the EMG SP and the errors in motor performance (as the difference between target and exerted force were analyzed. Results For the static force condition we found the well-documented, significant beta-range CMC (15–30 Hz over the contralateral sensorimotor cortex. Gamma-band CMC (30–45 Hz occurred in both small and large dynamic force conditions without any significant difference between both conditions. Although in some subjects beta-range CMC was observed during both dynamic force conditions no significant difference between conditions could be detected. With respect to the motor performance, the lowest errors were obtained in the static force condition and the highest ones in the dynamic condition with large amplitude. However, when we normalized the magnitude of the errors to the amplitude of the applied force (relative errors no significant difference between both dynamic conditions was observed. Conclusion These findings confirm that during dynamic force output the corticomuscular network oscillates at gamma frequencies. Moreover, we show that amplitude modulation of dynamic force has no

  11. Is cardiac autonomic modulation during upper limb isometric contraction and Valsalva maneuver impaired in COPD patients?

    Directory of Open Access Journals (Sweden)

    Goulart CL

    2017-03-01

    Full Text Available Cássia da Luz Goulart,1 Ramona Cabiddu,2 Paloma de Borba Schneiders,1 Elisabete Antunes San Martin,1 Renata Trimer,3 Audrey Borghi-Silva,2 Andréa Lúcia Gonçalves da Silva4,5 1Course of Physiotherapy, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 2Cardiopulmonary Physiotherapy Laboratory, Nucleus of Research in Physical Exercise, Federal University of São Carlos, São Carlos, Brazil; 3Department of Physiotherapy, Federal University of Amazonas, Manaus, AM, Brazil; 4Course of Physiotherapy, Department of Health and Physical Education, University of Santa Cruz do Sul, Rio Grande do Sul, Brazil; 5Pulmonary Rehabilitation Program, Santa Cruz Hospital, Santa Cruz do Sul, Rio Grande do Sul, Brazil Purpose: To evaluate the heart rate variability (HRV indices and heart rate (HR responses during isometric contraction (IC and Valsalva maneuver (VM in COPD patients. Methods: Twenty-two stable moderate to severe COPD patients were evaluated. R-R intervals were recorded (monitor Polar® S810i during dominant upper limb IC (2 minutes. Stable signals were analyzed by Kubios HRV® software. Indices of HRV were computed in the time domain (mean HR; square root of the mean squared differences of successive RR intervals [RMSSD] and HRV triangular index [RR tri index] and in the frequency domain (high frequency [HF]; low frequency [LF] and LF/HF ratio. The HR responses were evaluated at rest, at the peak and at the nadir of the VM (15 seconds. The Valsalva index was also calculated. Results: During IC: time domain indices (mean HR increased [P=0.001], RMSSD, and RR tri index decreased [P=0.005 and P=0.005, respectively]; frequency domain indices (LF increased [P=0.033] and HF decreased [P=0.002]; associations were found between forced expiratory volume in 1 second (FEV1 vs RMSSD (P=0.04; r=–0.55, FEV1 vs HR (P=0.04; r=–0.48, forced vital capacity (FVC vs RMSSD (P=0.05; r=–0.62, maximum inspiratory pressure (MIP vs HF (P=0.02; r=0.68. FEV1

  12. Numerical simulation of the force generated by a superelastic NiTi orthodontic archwire during tooth alignment phase: comparison between different constitutive models

    Science.gov (United States)

    Gannoun, M.; Laroussi Hellara, M.; Bouby, C.; Ben Zineb, T.; Bouraoui, T.

    2018-04-01

    Nickel Titanium (NiTi) Superelastic (SE) Shape Memory Alloys (SMAs) are widely considered for applications that need high reversible strain or high recovery forces. In particular, the SE SMAs present a high interest for biomedical applications such as endodontic and orthodontic apparatus. They are available in a large variety of archwires exerting continuum forces to ensure the dental displacement. The purpose of this study is to report the clinical implications of NiTi SE wires for dental treatment in a given configuration. Three main constitutive models of the literature (Lagoudas and Boyd 1996 Int. J. Plast. 12 805–842, Auricchio and Petrini 2004 Int. J. Numer. Meth. Engng. 61 807–836 and Chemisky et al 2011 Mech. Mater. 68 361–376) are considered for the finite element (FE) numerical simulations of the SMA archwires response. Tensile tests had been carried out in order to identify the material parameters of these constitutive models. The FE numerical study allowed to predict the dental displacement and its corresponding orthodontic force level exerted by the wire in similar conditions to those in the oral environment. This work allows to predict the orthodontic generated load by a NiTi SE archwire with a 0.64 × 0.46 mm2 rectangular cross section under prescribed thermomechanical conditions. The effect of the temperature and the alveolar bone stiffness on the orthodontic load level and the tooth displacement degree has been investigated. The performed numerical simulations demonstrate that the orthodontic load is sensitive to the displacement magnitude, to the tooth stiffness and to the temperature variations. The obtained forces applied continuously and at a constant level are within the acceptable orthodontic force level range. Some directives are therefore provided to help orthodontists to select the optimal archwire.

  13. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Manoela Fávaro Francisconi

    Full Text Available ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342, using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05. Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  14. Force and Directional Force Modulation Effects on Accuracy and Variability in Low-Level Pinch Force Tracking.

    Science.gov (United States)

    Park, Sangsoo; Spirduso, Waneen; Eakin, Tim; Abraham, Lawrence

    2018-01-01

    The authors investigated how varying the required low-level forces and the direction of force change affect accuracy and variability of force production in a cyclic isometric pinch force tracking task. Eighteen healthy right-handed adult volunteers performed the tracking task over 3 different force ranges. Root mean square error and coefficient of variation were higher at lower force levels and during minimum reversals compared with maximum reversals. Overall, the thumb showed greater root mean square error and coefficient of variation scores than did the index finger during maximum reversals, but not during minimum reversals. The observed impaired performance during minimum reversals might originate from history-dependent mechanisms of force production and highly coupled 2-digit performance.

  15. Control of force during rapid visuomotor force-matching tasks can be described by discrete time PID control algorithms.

    Science.gov (United States)

    Dideriksen, Jakob Lund; Feeney, Daniel F; Almuklass, Awad M; Enoka, Roger M

    2017-08-01

    Force trajectories during isometric force-matching tasks involving isometric contractions vary substantially across individuals. In this study, we investigated if this variability can be explained by discrete time proportional, integral, derivative (PID) control algorithms with varying model parameters. To this end, we analyzed the pinch force trajectories of 24 subjects performing two rapid force-matching tasks with visual feedback. Both tasks involved isometric contractions to a target force of 10% maximal voluntary contraction. One task involved a single action (pinch) and the other required a double action (concurrent pinch and wrist extension). 50,000 force trajectories were simulated with a computational neuromuscular model whose input was determined by a PID controller with different PID gains and frequencies at which the controller adjusted muscle commands. The goal was to find the best match between each experimental force trajectory and all simulated trajectories. It was possible to identify one realization of the PID controller that matched the experimental force produced during each task for most subjects (average index of similarity: 0.87 ± 0.12; 1 = perfect similarity). The similarities for both tasks were significantly greater than that would be expected by chance (single action: p = 0.01; double action: p = 0.04). Furthermore, the identified control frequencies in the simulated PID controller with the greatest similarities decreased as task difficulty increased (single action: 4.0 ± 1.8 Hz; double action: 3.1 ± 1.3 Hz). Overall, the results indicate that discrete time PID controllers are realistic models for the neural control of force in rapid force-matching tasks involving isometric contractions.

  16. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation.

    Science.gov (United States)

    Buist, Thomas J; Adiyaman, Ahmet; Smit, Jaap Jan J; Ramdat Misier, Anand R; Elvan, Arif

    2018-06-01

    The aim of this study was to compare second-generation cryoballoon and contact-force radiofrequency point-by-point pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients with regard to pulmonary vein reconnection and arrhythmia-free survival. Altogether, 269 consecutive patients with drug-refractory AF undergoing PVI were included and randomly allocated to second-generation cryoballoon or contact-force point-by-point radiofrequency ablation. Median follow-up duration was 389 days (interquartile range 219-599). Mean age was 59 years (71% male); 136 patients underwent cryoballoon and 133 patients underwent radiofrequency ablation. Acute electrical PVI was 100% for both techniques. Procedure duration was significantly shorter in cryoballoon vs radiofrequency (166.5 vs 184.13 min P = 0.016). Complication rates were similar (6.0 vs 6.7%, P = 1.00). Single procedure freedom of atrial arrhythmias was significantly higher in cryoballoon as compared to radiofrequency (75.2 vs 57.4%, P = 0.013). In multivariate analysis, persistent AF, AF duration, and cryoballoon ablation were associated with freedom of atrial tachyarrhythmias. The number of repeat ablation procedures was significantly lower in the cryoballoon compared to radiofrequency (15.0 vs 24.3%, P = 0.045). At repeat ablation, pulmonary vein reconnection rate was significantly lower after cryoballoon as compared to radiofrequency ablation (36.8 vs 58.1%, P = 0.003). Improved arrhythmia-free survival and more durable pulmonary vein isolation is seen after PVI using second-generation cryoballoon as compared to contact-force radiofrequency, in patients with drug-refractory paroxysmal AF. Complication rates for both ablation techniques are low.

  17. Comparison of acute countermovement jump responses after functional isometric and dynamic half squats.

    Science.gov (United States)

    Boyd, David A; Donald, Neil; Balshaw, Thomas G

    2014-12-01

    The purpose of this study was to compare acute countermovement jump (CMJ) responses after functional isometric (FI) and dynamic half (DH) squats. Ten strength-trained males (relative full back squat 1 repetition maximum [1RM]: 1.9 ± 0.2) participated in a randomized crossover design study. On 2 separate days, participants performed baseline CMJs followed by either FI or DH squats loaded with 150% of full back squat 1RM. Further CMJs were performed between 2 and 11 minutes after FI or DH squats. Kinematic and kinetic CMJ variables were measured. There were no differences observed between conditions when peak CMJ variables after FI or DH squats were compared with baseline values (p > 0.05). Countermovement jump time effects (p ≤ 0.05) were observed after squats. Increases in peak force (p ≤ 0.05; FI: 3.9%, range: -0.9 to 9.1%; DH: 4.2%, range: 0.0-11.5%) and decreases in peak power (p ≤ 0.05; FI: -0.4%, range: -5.1 to 4.0%; DH: -1.1%, range: -6.6 to 2.9%) occurred for combined condition data. Positive correlations between lower-body strength and the extent or timing of acute CMJ responses were not detected (p > 0.05). Because of the apparent lack of additive acute CMJ responses, the use of conventional DH squat protocols should be considered rather than FI squats in precompetition and training situations. Furthermore, the establishment of individual FI and DH squat protocols also seems to be necessary, rather than relying on relative lower-body strength to predict the nature of acute CMJ responses.

  18. Effect of Acute Effort on Isometric Strength and Body Balance: Trained vs. Untrained Paradigm.

    Directory of Open Access Journals (Sweden)

    Stanisław Sterkowicz

    Full Text Available Years of training in competitive sports leads to human body adaptation to a specific type of exercise. In judo bouts, maintaining hand grip on an opponent's clothes and postural balance is essential for the effective technical and tactical actions. This study compares changes after maximal anaerobic exercise among judo athletes and untrained subjects regarding 1 maximum isometric handgrip strength (HGSmax and accuracy at the perceived 50% maximum handgrip force (1/2HGSmax and 2 the balance of 13 judo athletes at national (n = 8 and international (n = 5 competitive levels and 19 untrained university students. The groups did not differ in age, body height, and weight. Body mass index (BMI and body composition (JAWON were evaluated. The Wingate Anaerobic Test (WAnT, Monark 875E measured recommended anaerobic capacity indices. Hand grip strength (Takei dynamometer and balance (biplate balance platform were measured before warm-up (T1, before the WAnT test (T2, and after (T3. Parametric or non-parametric tests were performed after verifying the variable distribution assumption. Judoists had higher BMI and fat-free mass index (FFMI than the students. The athletes also showed higher relative total work and relative peak power and lower levels of lactic acid. The difference in judoists between HGSmax at T1 and HGSmax at T3 was statistically significant. Before warm-up (T1, athletes showed higher strength (more divergent from the calculated ½HGSmax value compared to students. Substantial fatigue after the WAnT test significantly deteriorated the body stability indices, which were significantly better in judo athletes at all time points. The findings suggest specific body adaptations in judoists, especially for body composition, anaerobic energy system efficiency, and postural balance. These characteristics could be trained for specifically by judo athletes to meet the time-motion and anaerobic demands of contemporary bouts.

  19. Effect of Acute Effort on Isometric Strength and Body Balance: Trained vs. Untrained Paradigm.

    Science.gov (United States)

    Sterkowicz, Stanisław; Jaworski, Janusz; Lech, Grzegorz; Pałka, Tomasz; Sterkowicz-Przybycień, Katarzyna; Bujas, Przemysław; Pięta, Paweł; Mościński, Zenon

    2016-01-01

    Years of training in competitive sports leads to human body adaptation to a specific type of exercise. In judo bouts, maintaining hand grip on an opponent's clothes and postural balance is essential for the effective technical and tactical actions. This study compares changes after maximal anaerobic exercise among judo athletes and untrained subjects regarding 1) maximum isometric handgrip strength (HGSmax) and accuracy at the perceived 50% maximum handgrip force (1/2HGSmax) and 2) the balance of 13 judo athletes at national (n = 8) and international (n = 5) competitive levels and 19 untrained university students. The groups did not differ in age, body height, and weight. Body mass index (BMI) and body composition (JAWON) were evaluated. The Wingate Anaerobic Test (WAnT, Monark 875E) measured recommended anaerobic capacity indices. Hand grip strength (Takei dynamometer) and balance (biplate balance platform) were measured before warm-up (T1), before the WAnT test (T2), and after (T3). Parametric or non-parametric tests were performed after verifying the variable distribution assumption. Judoists had higher BMI and fat-free mass index (FFMI) than the students. The athletes also showed higher relative total work and relative peak power and lower levels of lactic acid. The difference in judoists between HGSmax at T1 and HGSmax at T3 was statistically significant. Before warm-up (T1), athletes showed higher strength (more divergent from the calculated ½HGSmax value) compared to students. Substantial fatigue after the WAnT test significantly deteriorated the body stability indices, which were significantly better in judo athletes at all time points. The findings suggest specific body adaptations in judoists, especially for body composition, anaerobic energy system efficiency, and postural balance. These characteristics could be trained for specifically by judo athletes to meet the time-motion and anaerobic demands of contemporary bouts.

  20. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    Science.gov (United States)

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  1. Relation between Peak Power Output in Sprint Cycling and Maximum Voluntary Isometric Torque Production.

    Science.gov (United States)

    Kordi, Mehdi; Goodall, Stuart; Barratt, Paul; Rowley, Nicola; Leeder, Jonathan; Howatson, Glyn

    2017-08-01

    From a cycling paradigm, little has been done to understand the relationships between maximal isometric strength of different single joint lower body muscle groups and their relation with, and ability to predict PPO and how they compare to an isometric cycling specific task. The aim of this study was to establish relationships between maximal voluntary torque production from isometric single-joint and cycling specific tasks and assess their ability to predict PPO. Twenty male trained cyclists participated in this study. Peak torque was measured by performing maximum voluntary contractions (MVC) of knee extensors, knee flexors, dorsi flexors and hip extensors whilst instrumented cranks measured isometric peak torque from MVC when participants were in their cycling specific position (ISOCYC). A stepwise regression showed that peak torque of the knee extensors was the only significant predictor of PPO when using SJD and accounted for 47% of the variance. However, when compared to ISOCYC, the only significant predictor of PPO was ISOCYC, which accounted for 77% of the variance. This suggests that peak torque of the knee extensors was the best single-joint predictor of PPO in sprint cycling. Furthermore, a stronger prediction can be made from a task specific isometric task. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. A Systematic Review of Isometric Lingual Strength-Training Programs in Adults With and Without Dysphagia.

    Science.gov (United States)

    McKenna, Victoria S; Zhang, Bin; Haines, Morgan B; Kelchner, Lisa N

    2017-05-17

    This systematic review summarizes the effects of isometric lingual strength training on lingual strength and swallow function in adult populations. Furthermore, it evaluates the designs of the reviewed studies and identifies areas of future research in isometric lingual strength training for dysphagia remediation. A comprehensive literature search of 3 databases and additional backward citation search identified 10 studies for inclusion in the review. The review reports and discusses the isometric-exercise intervention protocols, pre- and postintervention lingual-pressure data (maximum peak pressures and lingual-palatal pressures during swallowing), and oropharyngeal swallowing measures such as penetration-aspiration scales, oropharyngeal residue and duration, lingual volumes, and quality-of-life assessments. Studies reported gains in maximum peak lingual pressures following isometric lingual strength training for both healthy adults and select groups of individuals with dysphagia. However, due to the variability in study designs, it remains unclear whether strength gains generalize to swallow function. Although isometric lingual strength training is a promising intervention for oropharyngeal dysphagia, the current literature is too variable to confidently report specific therapeutic benefits. Future investigations should target homogenous patient populations and use randomized controlled trials to determine the efficacy of this treatment for individuals with dysphagia.

  3. Isometric elbow extensors strength in supine- and prone-lying positions.

    Science.gov (United States)

    Abdelzaher, Ibrahim E; Ababneh, Anas F; Alzyoud, Jehad M

    2013-01-01

    The purpose of this study was to compare isometric strength of elbow extensors measured in supine- and prone-lying positions at elbow flexion angles of 45 and 90 degrees. Twenty-two male subjects under single-blind procedures participated in the study. Each subject participated in both supine-lying and prone-lying measuring protocols. Calibrated cable tensiometer was used to measure isometric strength of the right elbow extensors and a biofeedback electromyography was used to assure no substitution movements from shoulder girdle muscles. The mean values of isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees were 11.1  ±  4.2 kg and 13.1  ±  4.6 kg, while those measured from prone-lying position were 9.9  ±  3.6 kg and 12  ±  4.2 kg, respectively. There is statistical significant difference between the isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees compared to that measured from prone-lying position (p  isometric strength of elbow extensors since supine-lying starting position is better than prone-lying starting position.

  4. Activation of selected shoulder muscles during unilateral wall and bench press tasks under submaximal isometric effort.

    Science.gov (United States)

    Tucci, Helga T; Ciol, Marcia A; de Araújo, Rodrigo C; de Andrade, Rodrigo; Martins, Jaqueline; McQuade, Kevin J; Oliveira, Anamaria S

    2011-07-01

    Controlled laboratory study. To assess the activation of 7 shoulder muscles under 2 closed kinetic chain (CKC) tasks for the upper extremity using submaximal isometric effort, thus providing relative quantification of muscular isometric effort for these muscles across the CKC exercises, which may be applied to rehabilitation protocols for individuals with shoulder weakness. CKC exercises favor joint congruence, reduce shear load, and promote joint dynamic stability. Additionally, knowledge about glenohumeral and periscapular muscle activity elicited during CKC exercises may help clinicians to design protocols for shoulder rehabilitation. Using surface electromyography, activation level was measured across 7 shoulder muscles in 20 healthy males, during the performance of a submaximal isometric wall press and bench press. Signals were normalized to the maximal voluntary isometric contraction, and, using paired t tests, data were analyzed between the exercises for each muscle. Compared to the wall press, the bench press elicited higher activity for most muscles, except for the upper trapezius. Levels of activity were usually low but were above 20% maximal voluntary isometric contraction for the serratus anterior on both tasks, and for the long head triceps brachii on the bench press. Both the bench press and wall press, as performed in this study, led to relatively low EMG activation levels for the muscles measured and may be considered for use in the early phases of rehabilitation.

  5. Accelerated generation of oligodendrocyte progenitor cells from human induced pluripotent stem cells by forced expression of Sox10 and Olig2.

    Science.gov (United States)

    Li, Pengyan; Li, Mo; Tang, Xihe; Wang, Shuyan; Zhang, Y Alex; Chen, Zhiguo

    2016-11-01

    Oligodendrocyte progenitor cells (OPCs) hold great promise for treatment of dysmyelinating disorders, such as multiple sclerosis and cerebral palsy. Recent studies on generation of human OPCs mainly use human embryonic stem cells (hESCs) or neural stem cells (NSCs) as starter cell sources for the differentiation process. However, NSCs are restricted in availability and the present method for generation of oligodendrocytes (OLs) from ESCs often requires a lengthy period of time. Here, we demonstrated a protocol to efficiently derive OPCs from human induced pluripotent stem cells (hiPSCs) by forced expression of two transcription factors (2TFs), Sox10 and Olig2. With this method, PDGFRα + OPCs can be obtained in 14 days and O4 + OPCs in 56 days. Furthermore, OPCs may be able to differentiate to mature OLs that could ensheath axons when co-cultured with rat cortical neurons. The results have implications in the development of autologous cell therapies.

  6. Generation of a Proton Motive Force by Histidine Decarboxylation and Electrogenic Histidine/Histamine Antiport in Lactobacillus buchneri

    OpenAIRE

    Molenaar, Douwe; Bosscher, Jaap S.; Brink, Bart ten; Driessen, Arnold J.M.; Konings, Wil N.

    1993-01-01

    Lactobacillus buchneri ST2A vigorously decarboxylates histidine to the biogenic amine histamine, which is excreted into the medium. Cells grown in the presence of histidine generate both a transmembrane pH gradient, inside alkaline, and an electrical potential (delta psi), inside negative, upon addition of histidine. Studies of the mechanism of histidine uptake and histamine excretion in membrane vesicles and proteoliposomes devoid of cytosolic histidine decarboxylase activity demonstrate tha...

  7. Generation of a proton motive force by histidine decarboxylation and electrogenic histidine/histamine antiport in Lactobacillus buchneri.

    Science.gov (United States)

    Molenaar, D; Bosscher, J S; ten Brink, B; Driessen, A J; Konings, W N

    1993-05-01

    Lactobacillus buchneri ST2A vigorously decarboxylates histidine to the biogenic amine histamine, which is excreted into the medium. Cells grown in the presence of histidine generate both a transmembrane pH gradient, inside alkaline, and an electrical potential (delta psi), inside negative, upon addition of histidine. Studies of the mechanism of histidine uptake and histamine excretion in membrane vesicles and proteoliposomes devoid of cytosolic histidine decarboxylase activity demonstrate that histidine uptake, histamine efflux, and histidine/histamine exchange are electrogenic processes. Histidine/histamine exchange is much faster than the unidirectional fluxes of these substrates, is inhibited by an inside-negative delta psi and is stimulated by an inside positive delta psi. These data suggest that the generation of metabolic energy from histidine decarboxylation results from an electrogenic histidine/histamine exchange and indirect proton extrusion due to the combined action of the decarboxylase and carrier-mediated exchange. The abundance of amino acid decarboxylation reactions among bacteria suggests that this mechanism of metabolic energy generation and/or pH regulation is widespread.

  8. Control Of Motor Unit Firing During Step-Like Increases In Voluntary Force

    Directory of Open Access Journals (Sweden)

    Xiaogang eHu

    2014-09-01

    Full Text Available In most skeletal muscles, force is generated by a combination of motor unit (MU recruitment and increases in the firing rate of previously active MUs. Two contrasting patterns of firing rate organization have been reported. In the first pattern, the earliest recruited MUs reach the highest firing rates as force is increased, and later recruited MUs fire at lower rates. When firing rate of multiple MUs are superimposed, these rate trajectories form a concentric layered profile termed ‘onion skin’. In the second pattern, called ‘reverse onion skin’, later recruited MUs reach higher firing rates, and crossing of firing rate trajectories for recorded MUs is common (although such trajectories are assembled routinely from different trials. Our present study examined the firing rate organization of concurrently active MUs of the first dorsal interosseous muscle during serial, step-like increases in isometric abduction forces. We used a surface sensor array coupled with MU discrimination algorithms to characterize MU firing patterns. Our objective was to determine whether ‘onion skin’ profiles are contingent upon the force trajectory of the motor task, examined here using step-like increases of force output, and also whether they are manifested at different force levels.Our results revealed that the overall ‘onion skin’ firing rate profile was retained as the force level increased with each force step up to 15% MVC. However, the distribution of firing rates across MUs was compressed with increasing force, and overlapping firing rate of units were observed. This rate compression was largely due to rate saturation of the relatively high frequency discharging MUs.Our results reflect flexible firing patterns across MUs at different levels of excitation drive. It is also evident that many units did not follow all the step increases consistently. This failure to track firing rate increases at higher forces could be due to an intrinsically

  9. The effect of local skin cooling before a sustained, submaximal isometric contraction on fatigue and isometric quadriceps femoris performance: A randomized controlled trial.

    Science.gov (United States)

    Hohenauer, Erich; Cescon, Corrado; Deliens, Tom; Clarys, Peter; Clijsen, Ron

    2017-04-01

    The central- and peripheral mechanisms by which heat strain limits physical performance are not fully elucidated. Nevertheless, pre-cooling is often used in an attempt to improve subsequent performance. This study compared the effects of pre-cooling vs. a pre-thermoneutral application on central- and peripheral fatigue during 60% of isometric maximum voluntary contraction (MVC) of the right quadriceps femoris muscle. Furthermore, the effects between a pre-cooling and a pre-thermoneutral application on isometric MVC of the right quadriceps femoris muscle and subjective ratings of perceived exertion (RPE) were investigated. In this randomized controlled trial, 18 healthy adults voluntarily participated. The participants received either a cold (experimental) application (+8°C) or a thermoneutral (control) application (+32°C) for 20min on their right thigh (one cuff). After the application, central (fractal dimension - FD) and peripheral (muscle fiber conduction velocity - CV) fatigue was estimated using sEMG parameters during 60% of isometric MVC. Surface EMG signals were detected from the vastus medialis and lateralis using bidimensional arrays. Immediately after the submaximal contraction, isometric MVC and RPE were assessed. Participants receiving the cold application were able to maintain a 60% isometric MVC significantly longer when compared to the thermoneutral group (mean time: 78 vs. 46s; p=0.04). The thermoneutral application had no significant impact on central fatigue (p>0.05) compared to the cold application (p=0.03). However, signs of peripheral fatigue were significantly higher in the cold group compared to the thermoneutral group (p=0.008). Pre-cooling had no effect on isometric MVC of the right quadriceps muscle and ratings of perceived exertion. Pre-cooling attenuated central fatigue and led to significantly longer submaximal contraction times compared to the pre-thermoneutral application. These findings support the use of pre-cooling procedures

  10. Structure and relative importance of ponderomotive forces and current drive generated by converted fast waves in pre-heated low aspect ratio tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Cuperman, S.; Bruma, C.; Komoshvili, K

    2003-05-12

    The generation in low aspect ratio tokamaks (LARTs) of ponderomotive forces and non-inductive current drive by the resonant fast wave-plasma interaction with mode conversion to kinetic Alfven waves (KAWs) and subsequent deposition, mainly by resonant electron Landau damping, is considered. The calculations follow the rigorous solution of the full wave equations upon using a dielectric tensor operator consisting of (i) a parallel conductivity including both kinetic effects (collisionless Landau damping on passing electrons) and collisional damping on both trapped electrons and passing electrons+ions and (ii) perpendicular components provided by the resistive two-fluid model equations. The fast waves are launched by an antenna located on the low field side and extending {+-}45 deg. about the equatorial plane. A parametric investigation of the structure and importance of the various components of the ponderomotive forces and current drive generated in START-like plasmas is carried out and their suitability for supplementing the required non-rf toroidal equilibrium current is demonstrated.

  11. Genuine two-fluid computations of laser-plasma interaction for generation of nonlinear force driven plasma blocks

    International Nuclear Information System (INIS)

    Nafari, F.; Yazdani, E.; Malekynia, B.; Ghoranneviss, M.

    2010-01-01

    Complete text of publication follows. Anomalous interaction of picosecond laser pulses of terawatt to petawatt power is due to suppression of relativistic self-focusing if prepulses are cut-off by a contrast ratio higher than 10 8 . Resulting non-linear ponderomotive forces induced at the skin-layer interaction of a short laser-pulse with a proper preplasma layer produced by the laser prepulse in front of a solid target accelerate two thin (a few μm) quasi-neutral plasma blocks, propagating in forward and backward directions, backward moving against the laser light (ablation) and forward moving into the target. This compressed block produces an ion current density of above 10 11 A/cm 2 . This may support the requirement to produce a fast ignition deuterium tritium fusion at densities not much higher than the solid state by a single shot pw-ps laser pulse. With studying skin-layer subrelativistic interaction of a short (≤ 1 ps) laser pulse with an initial Rayleigh density profile in genuine two-fluid hydrodynamic model, time and spatial distributions of ion block temperature are presented.

  12. Isometric Back Exercise Has Different Effect on Pressure Pain Thresholds in Healthy Men and Women

    DEFF Research Database (Denmark)

    Gajsar, Hannah; Titze, Christina; Hasenbring, Monika Ilona

    2017-01-01

    .07). CONCLUSIONS: The results of this pilot study indicate that isometric back exercise produces local and remote hypoalgesia. Remote EIH was only demonstrated in women, supporting the influence of sex in the hypoalgesic response after exercise. The effect of isometric back exercise on pain sensitivity in patients......OBJECTIVE: Isometric exercises produce an acute decrease in the pain sensitivity, known as exercise-induced hypoalgesia (EIH). Existing EIH paradigms use exercises at the extremities with more pronounced EIH at local compared to remote body sites, indicating local inhibition in addition to central...... inhibitory mechanisms. So far the results on EIH in patients with low back pain (LBP) are equivocal and no studies have investigated an EIH paradigm targeting the lower back in order to assess EIH in patients with LBP. Thus, the aim of this pilot study was to assess pressure pain sensitivity at local...

  13. Diurnal and day-to-day variation of isometric muscle strength in myasthenia gravis.

    Science.gov (United States)

    Vinge, Lotte; Jakobsen, Johannes; Pedersen, Asger Roer; Andersen, Henning

    2016-01-01

    In patients with myasthenia gravis (MG), muscle strength is expected to decrease gradually during the day due to physical activities. Isometric muscle strength at the shoulder, knee, and ankle was determined in 10 MG patients (MGFA class II-IV) who were receiving usual medical treatment and in 10 control subjects. To determine diurnal and day-to-day variation, muscle strength was measured 4 times during day 1 and once at day 2. Knee extension strength decreased during the day in both patients and controls. Neither diurnal nor day-to-day variation of muscle strength was higher in patients compared with controls. Patients with mild to moderate MG did not have increased variation of isometric muscle strength during the day or from day-to-day compared with controls. This suggests that isometric muscle performance can be determined with high reproducibility in similar groups of MG patients without regard to time of day. © 2015 Wiley Periodicals, Inc.

  14. Intermuscular force transmission between human plantarflexor muscles in vivo

    DEFF Research Database (Denmark)

    Bojsen-Møller, Jens; Schwartz, Sidse; Kalliokoski, Kari K

    2010-01-01

    of the present study was to investigate if intermuscular force transmission occurs within and between human plantarflexor muscles in vivo. Seven subjects performed four types of either active contractile tasks or passive joint manipulations: passive knee extension, voluntary isometric plantarflexion, voluntary...... surae muscles was seen during passive hallux extension. Large interindividual differences with respect to deep plantarflexor activation during voluntary contractions were observed. The present results suggest that force may be transmitted between the triceps surae muscles in vivo, while only limited...

  15. Cardinal features of involuntary force variability can arise from the closed-loop control of viscoelastic afferented muscles.

    Science.gov (United States)

    Nagamori, Akira; Laine, Christopher M; Valero-Cuevas, Francisco J

    2018-01-01

    Involuntary force variability below 15 Hz arises from, and is influenced by, many factors including descending neural drive, proprioceptive feedback, and mechanical properties of muscles and tendons. However, their potential interactions that give rise to the well-structured spectrum of involuntary force variability are not well understood due to a lack of experimental techniques. Here, we investigated the generation, modulation, and interactions among different sources of force variability using a physiologically-grounded closed-loop simulation of an afferented muscle model. The closed-loop simulation included a musculotendon model, muscle spindle, Golgi tendon organ (GTO), and a tracking controller which enabled target-guided force tracking. We demonstrate that closed-loop control of an afferented musculotendon suffices to replicate and explain surprisingly many cardinal features of involuntary force variability. Specifically, we present 1) a potential origin of low-frequency force variability associated with co-modulation of motor unit firing rates (i.e.,'common drive'), 2) an in-depth characterization of how proprioceptive feedback pathways suffice to generate 5-12 Hz physiological tremor, and 3) evidence that modulation of those feedback pathways (i.e., presynaptic inhibition of Ia and Ib afferents, and spindle sensitivity via fusimotor drive) influence the full spectrum of force variability. These results highlight the previously underestimated importance of closed-loop neuromechanical interactions in explaining involuntary force variability during voluntary 'isometric' force control. Furthermore, these results provide the basis for a unifying theory that relates spinal circuitry to various manifestations of altered involuntary force variability in fatigue, aging and neurological disease.

  16. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation

    Directory of Open Access Journals (Sweden)

    Kazuhiro eMatsui

    2014-06-01

    Full Text Available Functional electrical stimulation (FES is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly nonlinearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define theelectrical agonist-antagonist muscle ratio (EAA ratio and electrical agonist-antagonist muscle activity (EAA activity in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model.

  17. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation.

    Science.gov (United States)

    Matsui, Kazuhiro; Hishii, Yasuo; Maegaki, Kazuya; Yamashita, Yuto; Uemura, Mitsunori; Hirai, Hiroaki; Miyazaki, Fumio

    2014-01-01

    Functional electrical stimulation (FES) is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly non-linearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define the "electrical agonist-antagonist muscle ratio (EAA ratio)" and "electrical agonist-antagonist muscle activity (EAA activity)" in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG) signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model.

  18. Pressure pain and isometric strength of neck flexors are related in chronic tension-type headache.

    Science.gov (United States)

    Castien, Rene; Blankenstein, Annette; De Hertogh, Willem

    2015-01-01

    In patients with chronic tension-type headache (CTTH) changes in pressure pain in the cervical region are associated with peripheral or central sensitization. It is hypothesized that an increase of isometric strength of neck flexors would lead to a decrease of pressure pain in CTTH, as an expression of reduced peripheral or central sensitization In this study we aimed to analyze the correlation between change in isometric strength of the neck flexors and change in pressure pain scores (PPS) in patients with CTTH. Comparative analysis of data from previous study. Primary healthcare center. Data from 145 patients with CTTH who underwent a manual therapy program including isometric strength training of the neck flexors were analyzed at 8 and 26 weeks post-treatment. PPS were measured as a total of pain scores on a numeric rating scale (score 0 to 10) on application of a pressure stimulus of 3kg/cm at 8 cervical- and suboccipital muscles. Isometric strength of the neck flexors was measured in seconds. Correlations were computed between changes in PPS and isometric neck flexor strength. Isometric strength of neck flexors scored significantly different compared to baseline measurement (mean 30.0 seconds, sd:25.2), and increased with a mean difference of 17.33 seconds (95%CI: 20.61 to 14.05) at 8 weeks and 19.18 seconds (95%CI: 23.48 to 14.87) at 26 weeks. Similarly, compared to PPS baseline measurement (31.6 points, sd:18.6), mean difference in PPS was significantly decreased at 8 and 26 weeks: -11.3 points (95%CI: -8.77 to -13.83) and -11.15 points (95%CI: -8.31 to -13.99). There is a negative correlation between changes in PPS and changes in isometric strength of neck flexors which is weak at 8 weeks (r = -0.243, P = 0.004) and moderate at 26 weeks (r = -0.318, P isometric strength of neck flexors in patients with CTTH in short- and long-term.

  19. Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome

    NARCIS (Netherlands)

    Visser, J.; Mans, E.; de Visser, M.; van den Berg-Vos, R. M.; Franssen, H.; de Jong, J. M. B. V.; van den Berg, L. H.; Wokke, J. H. J.; de Haan, R. J.

    2003-01-01

    Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction.

  20. Predicting muscle forces of individuals with hemiparesis following stroke

    Directory of Open Access Journals (Sweden)

    Maladen Ryan

    2008-02-01

    Full Text Available Abstract Background Functional electrical stimulation (FES has been used to improve function in individuals with hemiparesis following stroke. An ideal functional electrical stimulation (FES system needs an accurate mathematical model capable of designing subject and task-specific stimulation patterns. Such a model was previously developed in our laboratory and shown to predict the isometric forces produced by the quadriceps femoris muscles of able-bodied individuals and individuals with spinal cord injury in response to a wide range of clinically relevant stimulation frequencies and patterns. The aim of this study was to test our isometric muscle force model on the quadriceps femoris, ankle dorsiflexor, and ankle plantar-flexor muscles of individuals with post-stroke hemiparesis. Methods Subjects were seated on a force dynamometer and isometric forces were measured in response to a range of stimulation frequencies (10 to 80-Hz and 3 different patterns. Subject-specific model parameter values were obtained by fitting the measured force responses from 2 stimulation trains. The model parameters thus obtained were then used to obtain predicted forces for a range of frequencies and patterns. Predicted and measured forces were compared using intra-class correlation coefficients, r2 values, and model error relative to the physiological error (variability of measured forces. Results Results showed excellent agreement between measured and predicted force-time responses (r2 >0.80, peak forces (ICCs>0.84, and force-time integrals (ICCs>0.82 for the quadriceps, dorsiflexor, and plantar-fexor muscles. The model error was within or below the +95% confidence interval of the physiological error for >88% comparisons between measured and predicted forces. Conclusion Our results show that the model has potential to be incorporated as a feed-forward controller for predicting subject-specific stimulation patterns during FES.

  1. Dystonic neck muscles show a shift in relative autospectral power during isometric contractions

    NARCIS (Netherlands)

    De Bruijn, E.; Nijmeijer, S. W. R.; Forbes, P. A.; Koelman, J. H. T. M.; Van Der Helm, F. C. T.; Tijssen, M. A. J.; Happee, R.

    2017-01-01

    Objective: To identify effects of a deviant motor drive in the autospectral power of dystonic muscles during voluntary contraction in cervical dystonia patients. Methods: Submaximal (20%) isometric head-neck tasks were performed with the head fixed, measuring surface EMG of the sternocleidomastoid,

  2. The effects of a 28-Hz vibration on arm muscle activity during isometric exercise

    NARCIS (Netherlands)

    Mischi, M.; Cardinale, M. (Marco)

    2009-01-01

    The aim of this study was to evaluate activation and coactivation of biceps and triceps muscles during isometric exercise performed with and without superimposing a vibration stimulation. Methods: Twelve healthy volunteers (age = 22.7 +/- 2.6 yr) participated in this study. The subjects performed

  3. The Relationship Between Maximum Isometric Strength and Ball Velocity in the Tennis Serve

    Directory of Open Access Journals (Sweden)

    Baiget Ernest

    2016-12-01

    Full Text Available The aims of this study were to analyze the relationship between maximum isometric strength levels in different upper and lower limb joints and serve velocity in competitive tennis players as well as to develop a prediction model based on this information. Twelve male competitive tennis players (mean ± SD; age: 17.2 ± 1.0 years; body height: 180.1 ± 6.2 cm; body mass: 71.9 ± 5.6 kg were tested using maximum isometric strength levels (i.e., wrist, elbow and shoulder flexion and extension; leg and back extension; shoulder external and internal rotation. Serve velocity was measured using a radar gun. Results showed a strong positive relationship between serve velocity and shoulder internal rotation (r = 0.67; p < 0.05. Low to moderate correlations were also found between serve velocity and wrist, elbow and shoulder flexion – extension, leg and back extension and shoulder external rotation (r = 0.36 – 0.53; p = 0.377 – 0.054. Bivariate and multivariate models for predicting serve velocity were developed, with shoulder flexion and internal rotation explaining 55% of the variance in serve velocity (r = 0.74; p < 0.001. The maximum isometric strength level in shoulder internal rotation was strongly related to serve velocity, and a large part of the variability in serve velocity was explained by the maximum isometric strength levels in shoulder internal rotation and shoulder flexion.

  4. Diurnal and day-to-day variation of isometric muscle strength in myasthenia gravis

    DEFF Research Database (Denmark)

    Vinge, Lotte; Jakobsen, Johannes; Pedersen, Asger Roer

    2016-01-01

    INTRODUCTION: In patients with myasthenia gravis (MG), muscle strength is expected to decrease gradually during the day due to physical activities. METHODS: Isometric muscle strength at the shoulder, knee, and ankle was determined in 10 MG patients (MGFA class II-IV) who were receiving usual...

  5. Effects of Isometric Hand-Grip Muscle Contraction on Young Adults' Free Recall and Recognition Memory

    Science.gov (United States)

    Tomporowski, Phillip D.; Albrecht, Chelesa; Pendleton, Daniel M.

    2017-01-01

    Purpose: The purpose of this study was to determine if physical arousal produced by isometric hand-dynamometer contraction performed during word-list learning affects young adults' free recall or recognition memory. Method: Twenty-four young adults (12 female; M[subscript age] = 22 years) were presented with 4 20-item word lists. Moderate arousal…

  6. Behaviour of motor units of human arm muscles: differences between slow isometric contraction and relaxation

    NARCIS (Netherlands)

    Denier van der Gon, J.J.; Haar Romenij, ter B.M.; Zuylen, Van E.J.

    1985-01-01

    The behaviour of motor units in the m. biceps brachii (long head), in the m. brachialis and in the m. supinator during slow isometric contraction and relaxation was studied when subjects were performing different motor tasks. These tasks were: flexion of the elbow joint, supination of the forearm

  7. Oxygenation and EMG in the proximal and distal vastus lateralis during submaximal isometric knee extension

    DEFF Research Database (Denmark)

    Crenshaw, Albert G.; Bronee, Lars; Krag, Ida

    2010-01-01

    /or (2) fatigue development. Nine males performed 2-min sustained isometric knee extensions at 15% and 30% maximum voluntary contraction during which oxygenation and EMG were recorded simultaneously from proximal and distal locations of the vastus lateralis muscle. Near infrared spectroscopy variables...

  8. Isometric muscle strength and mobility capacity in children with cerebral palsy

    NARCIS (Netherlands)

    Dallmeijer, Annet J.; Rameckers, Eugene A.; Houdijk, Han; de Groot, Sonja; Scholtes, Vanessa A.; Becher, Jules G.

    2017-01-01

    Purpose: To determine the relationship between isometric leg muscle strength and mobility capacity in children with cerebral palsy (CP) compared to typically developing (TD) peers. Method: Participants were 62 children with CP (6-13 years), able to walk with (n=10) or without (n=52) walking aids,

  9. Correlation between maximum isometric strength variables and specific performance of Brazilian military judokas

    Directory of Open Access Journals (Sweden)

    Michel Moraes Gonçalves

    2017-06-01

    Full Text Available It was our objective to correlate specific performance in the Special Judo Fitness Test (SJFT and the maximum isometric handgrip (HGSMax, scapular traction (STSMax and lumbar traction (LTSMax strength tests in military judo athletes. Twenty-two military athletes from the judo team of the Brazilian Navy Almirante Alexandrino Instruction Centre, with average age of 26.14 ± 3.31 years old, and average body mass of 83.23 ± 14.14 kg participated in the study. Electronic dynamometry tests for HGSMax, STSMax and LTSMax were conducted. Then, after approximately 1 hour-interval, the SJFT protocol was applied. All variables were adjusted to the body mass of the athletes. Pearson correlation coefficient for statistical analysis was used. The results showed moderate negative correlation between the SJFT index and STSMax (r= -0.550, p= 0.008, strong negative correlations between the SJFT index and HGSMax (r= -0.706, p< 0.001, SJFT index and LTSMax (r= -0.721; p= 0.001, besides the correlation between the sum of the three maximum isometric strength tests and the SJFT index (r= -0.786, p< 0.001. This study concludes that negative correlations occur between the SJFT index and maximum isometric handgrip, shoulder and lumbar traction strength and the sum of the three maximum isometric strength tests in military judokas.

  10. Short-term vascular hemodynamic responses to isometric exercise in young adults and in the elderly

    NARCIS (Netherlands)

    Hartog, R. (Renee); D. Bolignano (Davide); E.J.G. Sijbrands (Eric); Pucci, G. (Giacomo); F.U.S. Mattace Raso (Francesco)

    2018-01-01

    textabstractBackground: Vascular aging is known to induce progressive stiffening of the large elastic arteries, altering vascular hemodynamics under both rest and stress conditions. In this study, we aimed to investigate changes in vascular hemodynamics in response to isometric handgrip exercise

  11. Effects of trunk stability on isometric knee extension muscle strength measurement while sitting.

    Science.gov (United States)

    Hirano, Masahiro; Gomi, Masahiro; Katoh, Munenori

    2016-09-01

    [Purpose] This study aimed to investigate the effect of trunk stability on isometric knee extension muscle strength measurement while sitting by performing simultaneous measurements with a handheld dynamometer (HHD) and an isokinetic dynamometer (IKD) in the same seated condition. [Subjects and Methods] The subjects were 30 healthy volunteers. Isometric knee extension muscle strength was simultaneously measured with a HHD and an IKD by using an IKD-specific chair. The measurement was performed twice. Measurement instrument variables and the number of measurements were examined by using the analysis of variance and correlation tests. [Results] The measurement instrument variables and the number of measurements were not significantly different. The correlation coefficients between the HHD and IKD measurements were ≥0.96. [Conclusion] Isometric knee extension muscle strength measurement using the HHD in the sitting position resulted in a lower value than that using the IKD, presumably because of the effect of trunk stability on the measurement. In the same seated posture with trunk stability, no significant difference in measurement values was observed between the HHD and IKD. The present findings suggest that trunk stability while seated during isometric knee extension muscle strength measurement influenced the HHD measurement.

  12. The Relationship Between Maximum Isometric Strength and Ball Velocity in the Tennis Serve.

    Science.gov (United States)

    Baiget, Ernest; Corbi, Francisco; Fuentes, Juan Pedro; Fernández-Fernández, Jaime

    2016-12-01

    The aims of this study were to analyze the relationship between maximum isometric strength levels in different upper and lower limb joints and serve velocity in competitive tennis players as well as to develop a prediction model based on this information. Twelve male competitive tennis players (mean ± SD; age: 17.2 ± 1.0 years; body height: 180.1 ± 6.2 cm; body mass: 71.9 ± 5.6 kg) were tested using maximum isometric strength levels (i.e., wrist, elbow and shoulder flexion and extension; leg and back extension; shoulder external and internal rotation). Serve velocity was measured using a radar gun. Results showed a strong positive relationship between serve velocity and shoulder internal rotation (r = 0.67; p isometric strength level in shoulder internal rotation was strongly related to serve velocity, and a large part of the variability in serve velocity was explained by the maximum isometric strength levels in shoulder internal rotation and shoulder flexion.

  13. Pelvic floor muscle training decreases hip adductors isometric peak torque in incontinent women: an exploratory study

    Directory of Open Access Journals (Sweden)

    Grasiéla Nascimento Correia

    Full Text Available INTRODUCTION: The pelvic floor muscle (PFM training is the most common treatment for urinary incontinence (UI, however many women performed the contraction of PFM with associated contraction of abdominal, gluteus and hip adductors muscles. OBJECTIVE: To assess the effects of pelvic floor muscle (PFM training on isometric and isokinetic hip adductors peak torque (PT among women suffering from urinary incontinence (UI. MATERIALS AND METHODS: It is a longitudinal and prospective exploratory study. This study included 15 physically active women aged 45 years old and over, who presented complaints of UI. The PFM function (digital evaluation and perineometry, isometric and isokinetic hip adductors PT and one hour pad test were performed before and after treatment. The PFM training was performed in group, one hour once a week for 12 sessions. RESULTS: Significant improvement of PFM function and pressure level (p = 0.003, and significant decrease of hip adductors isometric PT and one-hour pad test, were found post-treatment. Moderate negative correlations between PFM contraction pressure and hip adductors isokinetic PT for dominant side (DS (r = -0.62; p = 0.03 and non-dominant side (NDS (r = -0.64; p = 0.02; and between PFM fast fibers contraction and hip adductors isometric PT for DS (r = -0.60; p = 0.03 and NDS (r = -0.59; p = 0.04 were also found. CONCLUSIONS: The PFM training decreased hip adductors PT and improved PFM functions and UI.

  14. Isometric strength, sprint power, and aerobic power in individuals with a spinal cord injury

    NARCIS (Netherlands)

    Janssen, T W; van Oers, C A; Hollander, A P; Veeger, DirkJan (H. E. J.); van der Woude, L H

    This study investigated in rather specific wheelchair tests the relationships among estimates of isometric upper-body strength (Fiso), sprint power (P30), aerobic power (VO2peak), and maximal power output (POaer) in a group of 44 men (age 34 +/- 12 yr) with longstanding spinal cord injuries ranging

  15. Efficacy of Interactive Whiteboard on Psychomotor Skills Achievement of Students in Isometric and Orthographic Projection

    Science.gov (United States)

    Gambari, Isiaka A.; Balogun, Sherifat A.; Alfa, Ahmadu S.

    2014-01-01

    This paper discusses importance of technology education and evidences of declining performance of junior secondary school students in basic technology subject. Potentials on interactive whiteboard (IWB) as one of the new technologies to meet the challenges of the 21st century are also discussed. The efficacy of IWB for teaching Isometric and…

  16. Deformation and three-dimensional displacement of fibers in isometrically contracting rat plantaris muscles

    NARCIS (Netherlands)

    Savelberg, Hans H.C.M.; Willems, Paul J.B.; Willems, P.; Baan, Guus C.; Huijing, P.A.J.B.M.

    2001-01-01

    In this study, the deformation of different fibers of the rat m. plantaris during isometric contractions at different muscle lengths was considered. Because the m. plantaris has an obviously inhomogeneous architecture, its fibers on the medial side of the muscle belly are judged to be shorter than

  17. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Cancer cachexia decreases specific force and accelerates fatigue in limb muscle

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, B. M. [1225 Center Drive, HPNP Building Room 1142, Department of Physical Therapy, University of Florida, Gainesville, FL 32610 (United States); Frye, G. S.; Ahn, B.; Ferreira, L. F. [1864 Stadium Road, Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32610 (United States); Judge, A.R., E-mail: arjudge@phhp.ufl.edu [1225 Center Drive, HPNP Building Room 1142, Department of Physical Therapy, University of Florida, Gainesville, FL 32610 (United States)

    2013-06-07

    Highlights: •C-26 cancer cachexia causes a significant decrease in limb muscle absolute force. •C-26 cancer cachexia causes a significant decrease in limb muscle specific force. •C-26 cancer cachexia decreases fatigue resistance in the soleus muscle. •C-26 cancer cachexia prolongs time to peak twitch tension in limb muscle. •C-26 cancer cachexia prolongs one half twitch relaxation time in limb muscle. -- Abstract: Cancer cachexia is a complex metabolic syndrome that is characterized by the loss of skeletal muscle mass and weakness, which compromises physical function, reduces quality of life, and ultimately can lead to mortality. Experimental models of cancer cachexia have recapitulated this skeletal muscle atrophy and consequent decline in muscle force generating capacity. However, more recently, we provided evidence that during severe cancer cachexia muscle weakness in the diaphragm muscle cannot be entirely accounted for by the muscle atrophy. This indicates that muscle weakness is not just a consequence of muscle atrophy but that there is also significant contractile dysfunction. The current study aimed to determine whether contractile dysfunction is also present in limb muscles during severe Colon-26 (C26) carcinoma cachexia by studying the glycolytic extensor digitorum longus (EDL) muscle and the oxidative soleus muscle, which has an activity pattern that more closely resembles the diaphragm. Severe C-26 cancer cachexia caused significant muscle fiber atrophy and a reduction in maximum absolute force in both the EDL and soleus muscles. However, normalization to muscle cross sectional area further demonstrated a 13% decrease in maximum isometric specific force in the EDL and an even greater decrease (17%) in maximum isometric specific force in the soleus. Time to peak tension and half relaxation time were also significantly slowed in both the EDL and the solei from C-26 mice compared to controls. Since, in addition to postural control, the oxidative

  19. Cancer cachexia decreases specific force and accelerates fatigue in limb muscle

    International Nuclear Information System (INIS)

    Roberts, B.M.; Frye, G.S.; Ahn, B.; Ferreira, L.F.; Judge, A.R.

    2013-01-01

    Highlights: •C-26 cancer cachexia causes a significant decrease in limb muscle absolute force. •C-26 cancer cachexia causes a significant decrease in limb muscle specific force. •C-26 cancer cachexia decreases fatigue resistance in the soleus muscle. •C-26 cancer cachexia prolongs time to peak twitch tension in limb muscle. •C-26 cancer cachexia prolongs one half twitch relaxation time in limb muscle. -- Abstract: Cancer cachexia is a complex metabolic syndrome that is characterized by the loss of skeletal muscle mass and weakness, which compromises physical function, reduces quality of life, and ultimately can lead to mortality. Experimental models of cancer cachexia have recapitulated this skeletal muscle atrophy and consequent decline in muscle force generating capacity. However, more recently, we provided evidence that during severe cancer cachexia muscle weakness in the diaphragm muscle cannot be entirely accounted for by the muscle atrophy. This indicates that muscle weakness is not just a consequence of muscle atrophy but that there is also significant contractile dysfunction. The current study aimed to determine whether contractile dysfunction is also present in limb muscles during severe Colon-26 (C26) carcinoma cachexia by studying the glycolytic extensor digitorum longus (EDL) muscle and the oxidative soleus muscle, which has an activity pattern that more closely resembles the diaphragm. Severe C-26 cancer cachexia caused significant muscle fiber atrophy and a reduction in maximum absolute force in both the EDL and soleus muscles. However, normalization to muscle cross sectional area further demonstrated a 13% decrease in maximum isometric specific force in the EDL and an even greater decrease (17%) in maximum isometric specific force in the soleus. Time to peak tension and half relaxation time were also significantly slowed in both the EDL and the solei from C-26 mice compared to controls. Since, in addition to postural control, the oxidative

  20. SIDE TO SIDE DIFFERENCES BETWEEN DOMINANT AND NON-DOMINANT ARM'S BONE DENSITY AND ISOMETRIC HANDGRIP STRENGTH IN MALES AND FEMALES AGED 40-65 YEARS OLD.

    Science.gov (United States)

    Krasniqi, Ermira; Koni, Mynyr; Kabashi, Antigona; Bahtiri, Abedin; Gjeli, Selda; Boshnjaku, Arben

    2016-10-01

    This observational, cross-sectional study, investigates and compares the differences of BMD, T-score, Z-score and isometric strength between dominant (D) versus non-dominant (ND) arms of 162 subjects aged 40-65 in a developing, low income country (Kosova). Bone Mineral Density (BMD), T-score and Z-score at distal forearm regions of both arms (measured by DXA scan), together with the Handgrip Isometric Strength (HIS) (by handgrip) were evaluated in a total subjects (53 Males and 109 Females). Additionally, General Healthcare Status Questionnaire together with self-administrated International Physical Activity Questionnaire (IPAQ) were filled. Significant differences (p0.05) were observed in Males BMD comparing to significantly higher results (p0.05) in males. When comparing the total subject's BMD, T-score, Z-score and Handgrip based on the PA levels (1 to 3 according to IPAQ scoring) no significant differences (p>0.05) were found between PA1, as well as PA3 whereas significantly differences (p<0.05) were found in D arms of PA2 level. The study analyses side-to-side differences in bone density and muscular force between D and ND arms amongst a population which is frequently exposed to diagnostic screenings for age related osteomuscular conditions (aged 40-60), and demonstrates that these differences should be in consideration amongst clinicians, but not in the way it is done right now.

  1. The Effect of an Isometric Hip Muscle Strength Training Protocol on Valgus Angle During a Drop Vertical Jump in Competitive Female Volleyball Players

    Directory of Open Access Journals (Sweden)

    Kaitlin M. Jackson

    2017-10-01

    Full Text Available Background: Hip muscle weakness is associated with higher peak knee valgus angles (VA during drop vertical jumps (DVJ and linked to ACL injury risk. Objective: To determine if isometric strengthening (IST of the hip extensor, abductor, and external rotator muscle groups would reduce VA exhibited during a DVJ. Methodology:  Fourteen female volleyball players (7 training (TG, 7 control (CG, VA≥9˚ during DVJ participated. Pre- and post-test gluteal, quadriceps and hamstring strength were measured with a digital force gauge. Three-dimensional kinematics were collected during 15 DVJ trials. TG participated in a 6-week IST program that targeted the hip extensor, abductor, and external rotator muscle groups. Two-way mixed ANOVAs compared mean differences of VA and strength. Single-participant analyses examined if athlete-specific adaptations went undetected in the analyses of aggregated data. Results: TG hip extension, abduction, and knee flexion strength increased, respectively, by 20.5%, 27.5% and 23.5% (P<0.05. No group-level changes in VA were detected. Unilateral VA decreased for 5 TG participants, and bilateral VA decreased in 2 TG participants. Conclusions: IST increased isometric hip muscle strength, but its effect on VA is inconclusive based on group-level analyses. Using single-participant designs, future studies should assess IST and/or dynamic resistance/neuromuscular training in a larger sample to determine its effect on ACL injury risk factors.

  2. Chronic Effects of Different Rest Intervals Between Sets on Dynamic and Isometric Muscle Strength and Muscle Activity in Trained Older Women.

    Science.gov (United States)

    Jambassi Filho, José Claudio; Gurjão, André Luiz Demantova; Ceccato, Marilia; Prado, Alexandre Konig Garcia; Gallo, Luiza Herminia; Gobbi, Sebastião

    2017-09-01

    This study investigated the chronic effects of different rest intervals (RIs) between sets on dynamic and isometric muscle strength and muscle activity. We used a repeated-measures design (pretraining and posttraining) with independent groups (different RI). Twenty-one resistance-trained older women (66.4 ± 4.4 years) were randomly assigned to either a 1-minute RI group (G-1 min; n = 10) or 3-minute RI group (G-3 min; n = 11). Both groups completed 3 supervised sessions per week during 8 weeks. In each session, participants performed 3 sets of 15 repetitions of leg press exercise, with a load that elicited muscle failure in the third set. Fifteen maximum repetitions, maximal voluntary contraction, peak rate of force development, and integrated electromyography activity of the vastus lateralis and vastus medialis muscles were assessed pretraining and posttraining. There was a significant increase in load of 15 maximum repetitions posttraining for G-3 min only (3.6%; P 0.05). The findings suggest that different RIs between sets did not influence dynamic and isometric muscle strength and muscle activity in resistance-trained older women.

  3. Effects of isotonic and isometric exercises with mist sauna bathing on cardiovascular, thermoregulatory, and metabolic functions

    Science.gov (United States)

    Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Nishimura, Rumiko; Sugenoya, Junichi; Miwa, Chihiro; Takada, Masumi

    2014-08-01

    To clarify the effects of isometric and isotonic exercise during mist sauna bathing on the cardiovascular function, thermoregulatory function, and metabolism, six healthy young men (22 ± 1 years old, height 173 ± 4 cm, weight 65.0 ± 5.0 kg) were exposed to a mist sauna for 10 min at a temperature of 40 °C, and relative humidity of 100 % while performing or not performing ˜30 W of isometric or isotonic exercise. The effect of the exercise was assessed by measuring tympanic temperature, heart rate, systolic and diastolic blood pressure, chest sweat rate, chest skin blood flow, and plasma catecholamine and cortisol, glucose, lactate, and free fatty acid levels. Repeated measures ANOVA showed no significant differences in blood pressure, skin blood flow, sweat rate, and total amount of sweating. Tympanic temperature increased more during isotonic exercise, and heart rate increase was more marked during isotonic exercise. The changes in lactate indicated that fatigue was not very great during isometric exercise. The glucose level indicated greater energy expenditure during isometric exercise. The free fatty acid and catecholamine levels indicated that isometric exercise did not result in very great energy expenditure and stress, respectively. The results for isotonic exercise of a decrease in lactate level and an increase in plasma free fatty acid level indicated that fatigue and energy expenditure were rather large while the perceived stress was comparatively low. We concluded that isotonic exercise may be a more desirable form of exercise during mist sauna bathing given the changes in glucose and free fatty acid levels.

  4. EFFICACY OF POST ISOMETRIC RELAXATION VERSUS STATIC STRECHING IN SUBJECTS WITH CHRONIC NON SPECIFIC NECK PAIN

    Directory of Open Access Journals (Sweden)

    P.Haritha

    2015-12-01

    Full Text Available Background: Neck pain is a common problem within our society. Upper trapezius sternocleidomastoid and the levator scapulae are the most common postural muscles that tends to get shorten leading to restricted neck mobility. There is lack of evidence to allow conclusions to be drawn about the effectiveness of post isometric relaxation when compared with static stretching exercises. The aim is to find out the effectiveness of Post isometric relaxation Versus Static stretching in the subjects with chronic nonspecific neck pain. To evaluate the effectiveness of post isometric relaxation technique on pain by using Visual analoge scale, range of motion by using Universal Goniometry, and functional disability by using Neck Disability Index in chronic nonspecific neck pain. Methods: A convenient sample of thirty seven subjects was diagnosed with nonspecific neck pain was randomly allocated to one of the two treatment groups on the basis of the inclusion criteria. The experimental group (n=15 received three sessions of post isometric relaxation technique for trapezius, sternocleidomastoid and the levator scapulae and control group (n=15 received the three sessions of static stretching for trapezius, sternocliedomastiod and levator scapulae for four weeks. Results: Non parametric tests demonstrated a statistically significant difference with experimental group showing greater improvement in ROM, VAS, and NDI than the control group and significant difference within the group also. Conclusion: This study concluded and the results reflected that post isometric relaxation technique group had better improvement in reduction of pain, improvement in the range of motion, and increased neck functional activities than the static stretching group.

  5. Effects of neck strength training on isometric neck strength in rugby union players.

    Science.gov (United States)

    Geary, Kevin; Green, Brian S; Delahunt, Eamonn

    2014-11-01

    To investigate the effectiveness of a neck strengthening program on the isometric neck strength profile of male rugby union players. Controlled laboratory study. Professional rugby union club. Fifteen professional and 10 semiprofessional rugby union players. The 15 professional players undertook a 5-week neck strengthening intervention, which was performed twice per week, whereas the 10 semiprofessional players acted as the control group. Isometric strength of the neck musculature was tested using a hand-held dynamometer, for flexion (F), extension (E), left-side flexion (LSF), and right-side flexion (RSF). Preintervention and postintervention evaluations were undertaken. No significant between-group differences in isometric neck strength were noted preintervention. A significant main effect for time was observed (P isometric neck strength in all planes after the 5-week intervention (F preintervention = 334.45 ± 39.31 N vs F postintervention 396.05 ± 75.55 N; E preintervention = 606.19 ± 97.34 vs E postintervention = 733.88 ± 127.16 N; LSF preintervention = 555.56 ± 88.34 N vs LSF postintervention = 657.14 ± 122.99 N; RSF preintervention = 570.00 ± 106.53 N vs RSF postintervention = 668.00 ± 142.18 N). No significant improvement in neck strength was observed for control group participants. The results of the present study indicate that a 5-week neck strengthening program improves isometric neck strength in rugby union players, which may have implications for injury prevention, screening, and rehabilitation. The strengthening program described in the present study may facilitate rehabilitation specialists in the development of neck injury prevention, screening, and rehabilitation protocols.

  6. Influences of Fascicle Length During Isometric Training on Improvement of Muscle Strength.

    Science.gov (United States)

    Tanaka, Hiroki; Ikezoe, Tome; Umehara, Jun; Nakamura, Masatoshi; Umegaki, Hiroki; Kobayashi, Takuya; Nishishita, Satoru; Fujita, Kosuke; Araki, Kojiro; Ichihashi, Noriaki

    2016-11-01

    Tanaka, H, Ikezoe, T, Umehara, J, Nakamura, M, Umegaki, H, Kobayashi, T, Nishishita, S, Fujita, K, Araki, K, and Ichihashi, N. Influences of fascicle length during isometric training on improvement of muscle strength. J Strength Cond Res 30(11): 3249-3255, 2016-This study investigated whether low-intensity isometric training would elicit a greater improvement in maximum voluntary contraction (MVC) at the same fascicle length, rather than the joint angle, adopted during training. Sixteen healthy women (21.8 ± 1.5 years) were randomly divided into an intervention group and a control group. Before (Pre) and after (Post) training, isometric plantarflexion MVCs were measured every 10° through the range of ankle joint position from 20° dorsiflexion to 30° plantarflexion (i.e., 6 ankle angles). Medial gastrocnemius fascicle length was also measured at each position, using B-mode ultrasound under 3 conditions of muscle activation: at rest, 30%MVC at respective angles, and MVC. Plantarflexion resistance training at an angle of 20° plantarflexion was performed 3 days a week for 4 weeks at 30%MVC using 3 sets of twenty 3-second isometric contractions. Maximum voluntary contraction in the intervention group increased at 0 and 10° plantarflexion (0°; Pre: 81.2 ± 26.5 N·m, Post: 105.0 ± 21.6 N·m, 10°; Pre: 63.0 ± 23.6 N·m, Post: 81.3 ± 20.3 N·m), which was not the angle used in training (20°). However, the fascicle length adopted in training at 20° plantarflexion and 30%MVC was similar to the value at 0 or 10° plantarflexion at MVC. Low-intensity isometric training at a shortened muscle length may be effective for improving MVC at a lengthened muscle length because of specificity of the fascicle length than the joint angle.

  7. Isometric muscle strength and mobility capacity in children with cerebral palsy.

    Science.gov (United States)

    Dallmeijer, Annet J; Rameckers, Eugene A; Houdijk, Han; de Groot, Sonja; Scholtes, Vanessa A; Becher, Jules G

    2017-01-01

    To determine the relationship between isometric leg muscle strength and mobility capacity in children with cerebral palsy (CP) compared to typically developing (TD) peers. Participants were 62 children with CP (6-13 years), able to walk with (n = 10) or without (n = 52) walking aids, and 47 TD children. Isometric muscle strength of five muscle groups of the leg was measured using hand-held dynamometry. Mobility capacity was assessed with the 1-min walk, the 10-m walk, sit-to-stand, lateral-step-up and timed-stair tests. Isometric strength of children with CP was reduced to 36-82% of TD. When adjusted for age and height, the percentage of variance in mobility capacity that was explained by isometric strength of the leg muscles was 21-24% (walking speed), 25% (sit-to-stand), 28% (lateral-step-up) and 35% (timed-stair) in children with CP. Hip abductors and knee flexors had the largest contribution to the explained variance, while knee extensors showed the weakest correlation. Weak or no associations were found between strength and mobility capacity in TD children. Isometric strength, especially hip abductor and knee flexor strength, is moderately related to mobility capacity in children with CP, but not in TD children. To what extent training of these muscle groups will lead to better mobility capacity needs further study. Implications for Rehabilitation Strength training in children with cerebral palsy (CP) may be targeted more specifically at hip abductors and knee flexors. The moderate associations imply that large improvements in mobility capacity may not be expected when strength increases.

  8. The association between submaximal quadriceps force steadiness and the knee adduction moment during walking in patients with knee osteoarthritis

    DEFF Research Database (Denmark)

    Sørensen, Tina Juul; Langberg, Henning; Aaboe, Jens

    2011-01-01

    in this population. METHODS: Forty-one patients with knee OA (34 females and 7 males) were included in the study. Submaximal isometric quadriceps force steadiness was measured during a force target-tracking task. Peak knee adduction moments during ambulation were measured using a 3-dimensional gait analysis system...

  9. Comparison of isokinetic and isometric strength training effects on hamstring and quadriceps torques and physical function in knee pain

    International Nuclear Information System (INIS)

    Masood, T.; Khan, H.M.M.H.

    2017-01-01

    To compare the effects of isokinetic and isometric strength trainings on hamstring and quadriceps average-peak-torques, physical performance, and pain. Methodology: Twenty athletes with knee pain were randomly assigned to two equal groups: Isokinetic training and isometric training. Both groups were trained on Biodex System 3 Pro for 10 sessions. Isokinetic-group received isokinetic training on 5 different velocities while isometric-group performed isometric contractions at 3 knee joint angles. Results: Hamstring isokinetic average-peak-torque was significantly higher at all velocities without significant improvement in quadriceps average-peak-torque except for at the slowest velocity. Isometric training did not cause significant change in isometric average-peak-torque at any knee angle for either hamstring or quadriceps. Agility, elastic leg strength, and pain improved significantly in both groups with no significant between-group differences. No significant statistical correlation was observed between pain and any other parameter after either type of training. Conclusions: Athletes participating in sports requiring dynamic hamstring strength should prefer isokinetic strength training for physical rehabilitation of knee pain. However, physical performance and pain can be improved with both isometric and isokinetic strength training. (author)

  10. Effect of isometric quadriceps exercise on muscle strength, pain, and function in patients with knee osteoarthritis: a randomized controlled study.

    Science.gov (United States)

    Anwer, Shahnawaz; Alghadir, Ahmad

    2014-05-01

    [Purpose] The aim of present study was to investigate the effects of isometric quadriceps exercise on muscle strength, pain, and function in knee osteoarthritis. [Subjects and Methods] Outpatients (N=42, 21 per group; age range 40-65 years; 13 men and 29 women) with osteoarthritis of the knee participated in the study. The experimental group performed isometric exercises including isometric quadriceps, straight leg raising, and isometric hip adduction exercise 5 days a week for 5 weeks, whereas the control group did not performed any exercise program. The outcome measures or dependent variables selected for this study were pain intensity, isometric quadriceps strength, and knee function. These variables were measured using the Numerical Rating Scale (NRS), strength gauge device, and reduced WOMAC index, respectively. All the measurements were taken at baseline (week 0) and at the end of the trial at week 5. [Results] In between-group comparisons, the maximum isometric quadriceps strength, reduction in pain intensity, and improvement in function in the isometric exercise group at the end of the 5th week were significantly greater than those of the control group (pisometric quadriceps exercise program showed beneficial effects on quadriceps muscle strength, pain, and functional disability in patients with osteoarthritis of the knee.

  11. Comparative efficacy and safety of contact force-sensing catheter and second-generation cryoballoon ablation for atrial fibrillation: a meta-analysis

    Directory of Open Access Journals (Sweden)

    X. Zhou

    Full Text Available This meta-analysis compared the efficacy and safety of the contact force (CF-sensing catheter and second-generation cryoballoon (CB ablation for treating atrial fibrillation (AF. Six controlled clinical trials comparing ablation for AF using a CF-sensing catheter or second-generation CB were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure. The procedure duration was significantly lower in the CB group compared with that in the CF group [mean difference (MD=29.4; 95%CI=17.84–40.96; P=0.01], whereas there was no difference between the groups for fluoroscopy duration (MD=0.59; 95%CI=–4.48–5.66; P=0.82. Moreover, there was no difference in the incidence of non-lethal complications (embolic event, tamponade, femoral/subclavian hematoma, arteriovenous fistula, pulmonary vein stenosis, phrenic nerve palsy, and esophageal injury between the CB and the CF groups (8.38 vs 5.35%; RR=0.66; 95%CI=0.37–1.17; P=0.15. Transient phrenic nerve palsy occurred in 17 of 326 patients (5.2% of the CB group vs none in the CF group (RR=0.12; 95%CI=0.03–0.43; P=0.001. A comparable proportion of patients in CF and CB groups suffered from AF recurrence during the 12-month follow-up after a single ablation procedure [risk ratio (RR=1.03; 95%CI=0.78–1.35; P=0.84]. AF ablation using CF-sensing catheters and second-generation CB showed comparable fluoroscopy duration and efficacy (during a 12-month follow-up, with shorter procedure duration and different complications in the CB group.

  12. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    Science.gov (United States)

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Exploiting the relationship between birefringence and force to measure airway smooth muscle contraction with PS-OCT (Conference Presentation)

    Science.gov (United States)

    Adams, David C.; Hariri, Lida P.; Holz, Jasmin A.; Szabari, Margit V.; Harris, R. Scott; Cho, Jocelyn L.; Hamilos, Daniel L.; Luster, Andrew D.; Medoff, Benjamin D.; Suter, Melissa J.

    2016-03-01

    The ability to observe airway dynamics is fundamental to forming a complete understanding of pulmonary diseases such as asthma. We have previously demonstrated that Optical Coherence Tomography (OCT) can be used to observe structural changes in the airway during bronchoconstriction, but standard OCT lacks the contrast to discriminate airway smooth muscle (ASM) bands- ASM being responsible for generating the force that drives airway constriction- from the surrounding tissue. Since ASM in general exhibits a greater degree of birefringence than the surrounding tissue, a potential solution to this problem lies in the implementation of polarization sensitivity (PS) to the OCT system. By modifying the OCT system so that it is sensitive to the birefringence of tissue under inspection, we can visualize the ASM with much greater clarity and definition. In this presentation we show that the force of contraction can be indirectly measured by an associated increase in the birefringence signal of the ASM. We validate this approach by attaching segments of swine trachea to an isometric force transducer and stimulating contraction, while simultaneously measuring the exerted force and imaging the segment with PS-OCT. We then show how our results may be used to extrapolate the force of contraction of closed airways in absence of additional measurement devices. We apply this technique to assess ASM contractility volumetrically and in vivo, in both asthmatic and non-asthmatic human volunteers.

  14. Polynomial conservation laws and exact solutions connected with isometrical and homothetic symmetries in the nonlinear sigma model

    International Nuclear Information System (INIS)

    Ivanov, G.G.

    1985-01-01

    In the non linear delta-model conserved tensor currents connected with the isometrical, homothetic and affine motions in the space Vsup(N) of the chiral field values are constructed. New classes of the exact solutions are obtained in the SO(3) and SO(5) invariant delta-models using the connection between the groups of isometrical and homothetic motions in the space-time and isometrical motions in Vsup(N). Some methods of obtaining exact solutions in 4-dimensional delta-model with non trivial topological charge are considered

  15. [Value of the isometric exercise test in objectively evaluating the effectiveness of hyperbaric oxygenation in ischemic heart disease].

    Science.gov (United States)

    Efuni, S N; Kudriashov, V E; Rodionov, V V; Beletskiĭ, Iu V; Telegin, Iu N

    1984-05-01

    The isometric test was conducted prior to and after a hyperbaric oxygenation (HBO) session in 31 coronary heart disease (CHD) patients. The results were compared with the findings provided by the examination of 138 coronary patients and 23 normal subjects receiving no HBO treatment. It was shown that the isometric test makes it possible to objectively assess the HBO effect in CHD patients. The results of the test reflect reduction in the severity of angina pectoris or cardiac failure following hyperbarotherpy. The results obtained justify the recommendation of the isometric test for the individual evaluation of the hyperbaric treatment in CHD.

  16. Report on Adaptive Force, a specific neuromuscular function

    Directory of Open Access Journals (Sweden)

    Marko Hoff

    2015-08-01

    Full Text Available In real life motions, as well as in sports, the adaptation of the neuromuscular systems to externally applied forces plays an important role. The term Adaptive Force (AF shall characterize the ability of the nerve-muscle-system to adapt to impacting external forces during isometric and eccentric muscle action. The focus in this paper is on the concept of this neuromuscular action, which is not yet described in this way. A measuring system was constructed and evaluated for this specific neuromuscular function, but only the main information of the evaluation of the measuring system and the preliminary reference values are mentioned here, while an article with detailed description will be published separately. This paper concentrates on the three following points: 1 What is the peculiarity of this neuromuscular function, introduced as AF? 2 Is the measuring system able to capture its specific characteristics and which phases of measurement occur? 3 It seems reasonable to discuss if AF can be distinguished and classified among the known force concepts. The article describes the measuring system and how it is able to capture special features of real life motions like submaximal intensities and the subjects’ option to react adequately on external varying forces. Furthermore, within one measurement the system records three different force qualities: the isometric submaximal Adaptive Force (AFiso, the maximal isometric Adaptive Force (AFisomax and the maximal eccentric Adaptive Force (AFeccmax. Each of these phases provide different and unique information on the nerve-muscle-system that are discussed in detail. Important, in terms of the Adaptive Force, seems to be the combination of conditional and coordinative abilities.

  17. Regular physical exercise improves cardiac autonomic and muscle vasodilatory responses to isometric exercise in healthy elderly

    Science.gov (United States)

    Sarmento, Adriana de Oliveira; Santos, Amilton da Cruz; Trombetta, Ivani Credidio; Dantas, Marciano Moacir; Oliveira Marques, Ana Cristina; do Nascimento, Leone Severino; Barbosa, Bruno Teixeira; Dos Santos, Marcelo Rodrigues; Andrade, Maria do Amparo; Jaguaribe-Lima, Anna Myrna; Brasileiro-Santos, Maria do Socorro

    2017-01-01

    The objective of this study was to evaluate cardiac autonomic control and muscle vasodilation response during isometric exercise in sedentary and physically active older adults. Twenty healthy participants, 10 sedentary and 10 physically active older adults, were evaluated and paired by gender, age, and body mass index. Sympathetic and parasympathetic cardiac activity (spectral and symbolic heart rate analysis) and muscle blood flow (venous occlusion plethysmography) were measured for 10 minutes at rest (baseline) and during 3 minutes of isometric handgrip exercise at 30% of the maximum voluntary contraction (sympathetic excitatory maneuver). Variables were analyzed at baseline and during 3 minutes of isometric exercise. Cardiac autonomic parameters were analyzed by Wilcoxon and Mann–Whitney tests. Muscle vasodilatory response was analyzed by repeated-measures analysis of variance followed by Tukey’s post hoc test. Sedentary older adults had higher cardiac sympathetic activity compared to physically active older adult subjects at baseline (63.13±3.31 vs 50.45±3.55 nu, P=0.02). The variance (heart rate variability index) was increased in active older adults (1,438.64±448.90 vs 1,402.92±385.14 ms, P=0.02), and cardiac sympathetic activity (symbolic analysis) was increased in sedentary older adults (5,660.91±1,626.72 vs 4,381.35±1,852.87, P=0.03) during isometric handgrip exercise. Sedentary older adults showed higher cardiac sympathetic activity (spectral analysis) (71.29±4.40 vs 58.30±3.50 nu, P=0.03) and lower parasympathetic modulation (28.79±4.37 vs 41.77±3.47 nu, P=0.03) compared to physically active older adult subjects during isometric handgrip exercise. Regarding muscle vasodilation response, there was an increase in the skeletal muscle blood flow in the second (4.1±0.5 vs 3.7±0.4 mL/min per 100 mL, P=0.01) and third minute (4.4±0.4 vs 3.9±0.3 mL/min per 100 mL, P=0.03) of handgrip exercise in active older adults. The results indicate that

  18. An experimental investigation into the deployment of 3-D, finned wing and shape memory alloy vortex generators in a forced air convection heat pipe fin stack

    International Nuclear Information System (INIS)

    Aris, M.S.; McGlen, R.; Owen, I.; Sutcliffe, C.J.

    2011-01-01

    Forced air convection heat pipe cooling systems play an essential role in the thermal management of electronic and power electronic devices such as microprocessors and IGBT's (Integrated Gate Bipolar Transistors). With increasing heat dissipation from these devices, novel methods of improving the thermal performance of fin stacks attached to the heat pipe condenser section are required. The current work investigates the use of a wing type surface protrusions in the form of 3-D delta wing tabs adhered to the fin surface, thin wings punched-out of the fin material and TiNi shape memory alloy delta wings which changed their angles of attack based on the fin surface temperature. The longitudinal vortices generated from the wing designs induce secondary mixing of the cooler free stream air entering the fin stack with the warmer fluid close to the fin surfaces. The change in angle of the attack of the active delta wings provide heat transfer enhancement while managing flow pressure losses across the fin stack. A heat transfer enhancement of 37% compared to a plain fin stack was obtained from the 3-D tabs in a staggered arrangement. The punched-out delta wings in the staggered and inline arrangements provided enhancements of 30% and 26% respectively. Enhancements from the active delta wings were lower at 16%. However, as these devices reduce the pressure drop through the fin stack by approximately 19% in the de-activate position, over the activated position, a reduction in fan operating cost may be achieved for systems operating with inlet air temperatures below the maximum inlet temperature specification for the device. CFD analysis was also carried out to provide additional detail of the local heat transfer enhancement effects. The CFD results corresponded well with previously published reports and were consistent with the experimental findings. - Highlights: → Heat transfer enhancements of heat pipe fin stacks was successfully achieved using fixed and active delta

  19. Relationship between isometric shoulder strength and arms-only swimming power among male collegiate swimmers: study of valid clinical assessment methods.

    Science.gov (United States)

    Awatani, Takenori; Morikita, Ikuhiro; Mori, Seigo; Shinohara, Junji; Tatsumi, Yasutaka

    2018-04-01

    [Purpose] The purpose of the present study was to confirm the relationships between shoulder strength (extensor strength and internal rotator strength) of the abducted position and swimming power during arm-only swimming. [Subjects and Methods] Fourteen healthy male collegiate swimmers participated in the study. Main measures were shoulder strength (strength using torque that was calculated from the upper extremity length and the isometric force of the abducted position) and swimming power. [Results] Internal rotation torque of the dominant side in the abducted external rotated position (r=0.85) was significantly correlated with maximum swimming power. The rate of bilateral difference in extension torque in the maximum abducted position (r=-0.728) was significantly correlated with the swimming velocity-to-swimming power ratio. [Conclusion] The results of this study suggest that internal rotator strength measurement in the abducted external rotated position and extensor strength measurement in the maximum abducted position are valid assessment methods for swimmers.

  20. Comparison of isometric cervical flexor and isometric cervical extensor system exercises on patients with neuromuscular imbalance and cervical crossed syndrome associated forward head posture.

    Science.gov (United States)

    Lee, Jaejin; Kim, Dohyeon; Yu, Kyunghoon; Cho, Youngki; You, Joshua H

    2018-01-01

    Isometric cervical flexor system exercise (ICF) and isometric cervical extensor system exercise (ICE) are cervical stabilization techniques that have been used to restore cervical crossed syndrome (CCS)-associated forward head posture. However, the therapeutic effects and underlying motor control mechanisms remain elusive. The purpose of present study was investigating the concurrent therapeutic effects of ICF and ICE on muscle size, muscle imbalance ratio, and muscle recruitment sequence using ultrasound imaging and electromyography. A total of 18 participants (7 females; age=24±4.0 years) with CCS associated with forward head posture underwent ICF and ICE. Paired t-test analysis was used for statistical analysis. Paired t-test analysis showed that sternocleidomastoid thickness was greater during ICF than ICE. Similarly, cross-sectional area and horizontal thickness of the longus colli were greater during ICE than ICF. The upper trapezius/lower trapezius muscle imbalance ratio and the pectoralis major/lower trapezius muscle imbalance ratio were significantly decreased during the application of ICE compared to ICF. These results provide compelling, mechanistic evidence as to how ICE is more beneficial for the restoration of neuromuscular imbalance than ICF in individuals with CCS.

  1. Phase transition behaviors of the supported DPPC bilayer investigated by sum frequency generation (SFG) vibrational spectroscopy and atomic force microscopy (AFM).

    Science.gov (United States)

    Wu, Heng-Liang; Tong, Yujin; Peng, Qiling; Li, Na; Ye, Shen

    2016-01-21

    The phase transition behaviors of a supported bilayer of dipalmitoylphosphatidyl-choline (DPPC) have been systematically evaluated by in situ sum frequency generation (SFG) vibrational spectroscopy and atomic force microscopy (AFM). By using an asymmetric bilayer composed of per-deuterated and per-protonated monolayers, i.e., DPPC-d75/DPPC and a symmetric bilayer of DPPC/DPPC, we were able to probe the molecular structural changes during the phase transition process of the lipid bilayer by SFG spectroscopy. It was found that the DPPC bilayer is sequentially melted from the top (adjacent to the solution) to bottom leaflet (adjacent to the substrate) over a wide temperature range. The conformational ordering of the supported bilayer does not decrease (even slightly increases) during the phase transition process. The conformational defects in the bilayer can be removed after the complete melting process. The phase transition enthalpy for the bottom leaflet was found to be approximately three times greater than that for the top leaflet, indicating a strong interaction of the lipids with the substrate. The present SFG and AFM observations revealed similar temperature dependent profiles. Based on these results, the temperature-induced structural changes in the supported lipid bilayer during its phase transition process are discussed in comparison with previous studies.

  2. Changes in the micro-circulation of skeletal muscle due to varied isometric exercise assessed by contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Krix, Martin; Weber, Marc-Andre; Kauczor, Hans-Ulrich; Delorme, Stefan; Krakowski-Roosen, Holger

    2010-01-01

    Purpose: To quantitatively assess local muscle micro-circulation with real-time contrast-enhanced ultrasound (CEUS) during different exercises and compare the results with performed muscle work and global blood flow. Materials and methods: Sixteen low mechanical index CEUS examinations of the right lower leg flexors of healthy volunteers were performed using a continuous infusion of SonoVue (4.8 mL/300 s). Several muscle perfusion parameters were extracted from derived CEUS signal intensity time curves during different isometric exercises (10-50% of maximum individual strength for 20-30 s) and then correlated with the performed muscle work or force, and the whole lower leg blood flow which we measured simultaneously by venous occlusion plethysmography (VOP). Results: The shapes of the CEUS curve during and after exercise differed individually depending on the performed muscle work. The maximum blood volume MAX was observed only after exercise cessation and was significantly correlated with the performed muscle force (r = 0.77, p < 0.0001). The blood volume over exercise time was inversely correlated with the spent muscle work (r = -0.60, p = 0.006). CEUS and VOP measurements correlated only at rest and after the exercise. During exercise, mean CEUS local blood volume decreased (from 3.48 to 2.19 (∼mL)), while mean VOP global blood flow increased (mean, from 3.96 to 7.71 mL/100 mg/min). Conclusion: Real-time low-MI CEUS provides complementary information about the local muscle micro-circulation compared to established blood flow measures. CEUS may be used for a better understanding of muscle perfusion physiology and in the diagnosis of micro-circulation alterations such as in peripheral arterial occlusive disease or diabetic angiopathy.

  3. Greater glucose uptake heterogeneity in knee muscles of old compared to young men during isometric contractions detected by [18F]-FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Thorsten eRudroff

    2014-05-01

    Full Text Available We used positron emission tomography/computed tomography (PET/CT and [18F]-FDG to test the hypothesis that glucose uptake (GU heterogeneity in skeletal muscles as a measure of heterogeneity in muscle activity is greater in old than young men when they perform isometric contractions. Six young (26 ± 6 yrs and six old (77 ± 6 yrs men performed two types of submaximal isometric contractions that required either force or position control. [18F]-FDG was injected during the task and PET/CT scans were performed immediately after the task. Within-muscle heterogeneity of knee muscles was determined by calculating the coefficient of variation (CV of GU in PET image voxels within the muscles of interest. The average GU heterogeneity (mean ± SD for knee extensors and flexors was greater for the old (35.3 ± 3.3 % than the young (28.6 ± 2.4 % (P = 0.006. Muscle volume of the knee extensors were greater for the young compared to the old men (1016 ± 163 vs. 598 ± 70 cm3, P= 0.004. In a multiple regression model, knee extensor muscle volume was a predictor (partial r = - 0.87; P = 0.001 of GU heterogeneity for old men (R2 = 0.78; P < 0.001, and MVC force predicted GU heterogeneity for young men (partial r = - 0.95, P < 0.001. The findings demonstrate that glucose uptake is more spatially variable for old than young men and especially so for old men who exhibit greater muscle atrophy.

  4. ANODAL TRANSCRANIAL DIRECT CURRENT STIMULATION (TDCS) INCREASES ISOMETRIC STRENGTH OF SHOULDER ROTATORS MUSCLES IN HANDBALL PLAYERS.

    Science.gov (United States)

    Hazime, Fuad Ahmad; da Cunha, Ronaldo Alves; Soliaman, Renato Rozenblit; Romancini, Ana Clara Bezerra; Pochini, Alberto de Castro; Ejnisman, Benno; Baptista, Abrahão Fontes

    2017-06-01

    Weakness of the rotator cuff muscles can lead to imbalances in the strength of shoulder external and internal rotators, change the biomechanics of the glenohumeral joint and predispose an athlete to injury. Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation technique that has demonstrated promising results in a variety of health conditions. However few studies addressed its potential approach in the realm of athletics. The purpose of this study was to investigate if transcranial direct current stimulation (tDCS) technique increases the isometric muscle strength of shoulder external and internal rotators in handball athletes. Randomized, double-blind, placebo-controlled, crossover study. Eight female handball players aged between 17 and 21 years (Mean=19.65; SD=2.55) with 7.1 ± 4.8 years of experience in training, participating in regional and national competitions were recruited. Maximal voluntary isometric contraction (MVIC) of shoulder external and internal rotator muscles was evaluated during and after 30 and 60 minutes post one session of anodal and sham current (2mA; 0.057mA/cm 2 ) with a one-week interval between stimulations. Compared to baseline, MVIC of shoulder external and internal rotators significantly increased after real but not sham tDCS. Between-group differences were observed for external and internal rotator muscles. Maximal voluntary isometric contraction of external rotation increased significantly during tDCS, and 30 and 60 minutes post-tDCS for real tDCS compared to that for sham tDCS. For internal rotation MVIC increased significantly during and 60 minutes post-tDCS. The results indicate that transcranial direct current stimulation temporarily increases maximal isometric contractions of the internal and external rotators of the shoulder in handball players. 2.

  5. Quasi-local mass via isometric embeddings: a review from a geometric perspective

    International Nuclear Information System (INIS)

    Miao, Pengzi

    2015-01-01

    In this paper, we review geometric aspects of quasi-local energies proposed by Brown–York, Liu–Yau, and Wang–Yau. These quasi-local energy functions, having the important positivity property, share a common feature that they are defined via the canonical Hamiltonian approach, and therefore an isometric embedding of the two-surface into a background space is used as a reference. (topical review)

  6. Effect of long-term isometric training on core/torso stiffness.

    Science.gov (United States)

    Lee, Benjamin C Y; McGill, Stuart M

    2015-06-01

    Although core stiffness enhances athletic performance traits, controversy exists regarding the effectiveness of isometric vs. dynamic core training methods. This study aimed to determine whether long-term changes in stiffness can be trained, and if so, what is the most effective method. Twenty-four healthy male subjects (23 ± 3 years; 1.8 ± 0.06 m; 77.5 ± 10.8 kg) were recruited for passive and active stiffness measurements before and after a 6-week core training intervention. Twelve subjects (22 ± 2 years; 1.8 ± 0.08 m; 78.3 ± 12.3 kg) were considered naive to physical and core exercise. The other 12 subjects (24 ± 3 years; 1.8 ± 0.05 m; 76.8 ± 9.7 kg) were Muay Thai athletes (savvy). A repeated-measures design compared core training methods (isometric vs. dynamic, with a control group) and subject training experience (naive vs. savvy) before and after a 6-week training period. Passive stiffness was assessed on a "frictionless" bending apparatus and active stiffness assessed through a quick release mechanism. Passive stiffness increased after the isometric training protocol. Dynamic training produced a smaller effect, and as expected, there was no change in the control group. Active stiffness did not change in any group. Comparisons between subject and training groups did not reveal any interactions. Thus, an isometric training approach was superior in terms of enhancing core stiffness. This is important since increased core stiffness enhances load bearing ability, arrests painful vertebral micromovements, and enhances ballistic distal limb movement. This may explain the efficacy reported for back and knee injury reduction.

  7. Isometric surfaces with a common mean curvature and the problem of Bonnet pairs

    International Nuclear Information System (INIS)

    Sabitov, Idzhad Kh

    2012-01-01

    Simple methods are used to give new proofs, and sometimes to make them more precise, of basic theorems on isometric surfaces with a common mean curvature, which are usually called Bonnet pairs. The considerations are conducted under the assumption of minimally admissible smoothness of the objects in question, and certain necessary or sufficient criteria are given for the non-existence of Bonnet pairs with a common non-constant mean curvature among compact surfaces. Bibliography: 26 titles.

  8. Comparison of sympathetic nerve responses to neck and forearm isometric exercise

    Science.gov (United States)

    Steele, S. L. Jr; Ray, C. A.

    2000-01-01

    PURPOSE: Although the autonomic and cardiovascular responses to arm and leg exercise have been studied, the sympathetic adjustments to exercise of the neck have not. The purpose of the present study was twofold: 1) to determine sympathetic and cardiovascular responses to isometric contractions of the neck extensors and 2) to compare sympathetic and cardiovascular responses to isometric exercise of the neck and forearm. METHODS: Muscle sympathetic nerve activity (MSNA), mean arterial pressure (MAP), and heart rate were measured in nine healthy subjects while performing isometric neck extension (INE) and isometric handgrip (IHG) in the prone position. After a 3-min baseline period, subjects performed three intensities of INE for 2.5 min each: 1) unloaded (supporting head alone), 2) 10% maximal voluntary contraction (MVC), and 3) 30% MVC, then subjects performed two intensities (10% and 30% MVC) of IHG for 2.5 min. RESULTS: Supporting the head by itself did not significantly change any of the variables. During [NE, MAP significantly increased by 10 +/- 2 and 31 +/- 4 mm Hg and MSNA increased by 67 +/- 46 and 168 +/- 36 units/30 s for 10% and 30% MVC, respectively. IHG and INE evoked similar responses at 10% MVC, but IHG elicited higher peak MAP and MSNA at 30% MVC (37 +/- 7 mm Hg (P INE can elicit marked increases in MSNA and cardiovascular responses but that it evokes lower peak responses as compared to IHG. We speculate that possible differences in muscle fiber type composition, muscle mass, and/or muscle architecture of the neck and forearm are responsible for these differences in peak responses.

  9. Comparison in muscle damage between maximal voluntary and electrically evoked isometric contractions of the elbow flexors.

    Science.gov (United States)

    Jubeau, Marc; Muthalib, Makii; Millet, Guillaume Y; Maffiuletti, Nicola A; Nosaka, Kazunori

    2012-02-01

    This study compared between maximal voluntary (VOL) and electrically stimulated (ES) isometric contractions of the elbow flexors for changes in indirect markers of muscle damage to investigate whether ES would induce greater muscle damage than VOL. Twelve non-resistance-trained men (23-39 years) performed VOL with one arm and ES with the contralateral arm separated by 2 weeks in a randomised, counterbalanced order. Both VOL and ES (frequency 75 Hz, pulse duration 250 μs, maximally tolerated intensity) exercises consisted of 50 maximal isometric contractions (4-s on, 15-s off) of the elbow flexors at a long muscle length (160°). Changes in maximal voluntary isometric contraction torque (MVC), range of motion, muscle soreness, pressure pain threshold and serum creatine kinase (CK) activity were measured before, immediately after and 1, 24, 48, 72 and 96 h following exercise. The average peak torque over the 50 isometric contractions was greater (P < 0.05) for VOL (32.9 ± 9.8 N m) than ES (16.9 ± 6.3 N m). MVC decreased greater and recovered slower (P < 0.05) after ES (15% lower than baseline at 96 h) than VOL (full recovery). Serum CK activity increased (P < 0.05) only after ES, and the muscles became more sore and tender after ES than VOL (P < 0.05). These results showed that ES induced greater muscle damage than VOL despite the lower torque output during ES. It seems likely that higher mechanical stress imposed on the activated muscle fibres, due to the specificity of motor unit recruitment in ES, resulted in greater muscle damage.

  10. Effect of Strength Training on Rate of Force Development in Older Women

    Science.gov (United States)

    Gurjao, Andre Luiz Demantova; Gobbi, Lilian Teresa Bucken; Carneiro, Nelson Hilario; Goncalves, Raquel; Ferreira de Moura, Rodrigo; Cyrino, Edilson Serpeloni; Altimari, Leandro Ricardo; Gobbi, Sebastiao

    2012-01-01

    We analyzed the effect of an 8-week strength training (ST) program on the rate of force development (RFD) and electromyographic activity (EMG) in older women. Seventeen women (M age = 63.4 years, SD = 4.9) without previous ST experience were randomly assigned to either a control (n = 7) or training (n = 10) group. A leg-press isometric test was…

  11. Estimation of 1RM for knee extension based on the maximal isometric muscle strength and body composition

    OpenAIRE

    Kanada, Yoshikiyo; Sakurai, Hiroaki; Sugiura, Yoshito; Arai, Tomoaki; Koyama, Soichiro; Tanabe, Shigeo

    2017-01-01

    [Purpose] To create a regression formula in order to estimate 1RM for knee extensors, based on the maximal isometric muscle strength measured using a hand-held dynamometer and data regarding the body composition. [Subjects and Methods] Measurement was performed in 21 healthy males in their twenties to thirties. Single regression analysis was performed, with measurement values representing 1RM and the maximal isometric muscle strength as dependent and independent variables, respectively. Furth...

  12. Interactive effect of aging and local muscle heating on renal vasoconstriction during isometric handgrip.

    Science.gov (United States)

    Kuipers, Nathan T; Sauder, Charity L; Kearney, Matthew L; Ray, Chester A

    2009-08-01

    The purpose of the study was to determine the interactive effect of aging and forearm muscle heating on renal vascular conductance and muscle sympathetic nerve activity (MSNA) during ischemic isometric handgrip. A tube-lined, water-perfused sleeve was used to heat the forearm in 12 young (27 +/- 1 yr) and 9 older (63 +/- 1 yr) subjects. Ischemic isometric handgrip was performed before and after heating. Muscle temperature (intramuscular thermistor) was 34.3 +/- 0.2 and 38.7 +/- 0.1 degrees C during normothermia and heating, respectively. At rest, heating had no effect on renal blood velocity (Doppler ultrasound) or renal vascular conductance in either group (young, n = 12; older, n = 8). Heating compared with normothermia caused a significantly greater increase in renal vasoconstriction during exercise and postexercise muscle ischemia (PEMI) in both groups. However, the increase in renal vasoconstriction during heating was greater in the older compared with the young subjects (18 +/- 3 vs. 8 +/- 3%). During handgrip, heating elicited greater increases in MSNA responses in the older group (young, n = 12; older, n = 6), whereas no statistical difference was observed between groups during PEMI. In summary, aging augments renal vascular responses to ischemic isometric handgrip during heating of the exercising muscle. The greater renal vasoconstriction was associated with augmented MSNA in the older subjects.

  13. Salient Point Detection in Protrusion Parts of 3D Object Robust to Isometric Variations

    Science.gov (United States)

    Mirloo, Mahsa; Ebrahimnezhad, Hosein

    2018-03-01

    In this paper, a novel method is proposed to detect 3D object salient points robust to isometric variations and stable against scaling and noise. Salient points can be used as the representative points from object protrusion parts in order to improve the object matching and retrieval algorithms. The proposed algorithm is started by determining the first salient point of the model based on the average geodesic distance of several random points. Then, according to the previous salient point, a new point is added to this set of points in each iteration. By adding every salient point, decision function is updated. Hence, a condition is created for selecting the next point in which the iterative point is not extracted from the same protrusion part so that drawing out of a representative point from every protrusion part is guaranteed. This method is stable against model variations with isometric transformations, scaling, and noise with different levels of strength due to using a feature robust to isometric variations and considering the relation between the salient points. In addition, the number of points used in averaging process is decreased in this method, which leads to lower computational complexity in comparison with the other salient point detection algorithms.

  14. The effectiveness of isometric exercises as compared to general exercises in the management of chronic non-specific neck pain.

    Science.gov (United States)

    Khan, Muhammad; Soomro, Rabail Rani; Ali, Syed Shahzad

    2014-09-01

    To evaluate the effectiveness of isometric exercises as compared to general exercises in chronic non-specific neck pain. For this randomised controlled trial total 68 patients (34 each group) with chronic non-specific neck pain were recruited from Alain Poly Clinic and Institute of Physical Medicine & Rehabilitation Dow University of Health Sciences, Karachi between May, 2012 and August, 2012. Simple randomisation method was used to assign participants into isometric exercise group and general exercise groups. The isometric exercise group performed exercises for neck muscle groups with a rubber band and general exercises group performed active range of movement exercises for all neck movements. Patients in both groups received 3 supervised treatment sessions per week for 12 weeks. Visual Analogue Scale (VAS), North wick Park Neck Pain Questionnaire and goniometer were used to assess pain, disability and neck range of movements at baseline and after 12 weeks. Both interventions showed statistically significant improvements in pain, function and range of movement p = 0.001f or isometric exercise group, p = 0.04 for general exercises group and p = 0.001 for range of movement. However, mean improvements in post intervention VAS score and North wick Park Neck Pain Questionnaire score was better in isometric exercises group as compared to general exercise group. In conclusion, both interventions are effective in the treatment of chronic non-specific neck pain however; isometric exercises are clinically more effective than general exercises.

  15. Estimation of 1RM for knee extension based on the maximal isometric muscle strength and body composition.

    Science.gov (United States)

    Kanada, Yoshikiyo; Sakurai, Hiroaki; Sugiura, Yoshito; Arai, Tomoaki; Koyama, Soichiro; Tanabe, Shigeo

    2017-11-01

    [Purpose] To create a regression formula in order to estimate 1RM for knee extensors, based on the maximal isometric muscle strength measured using a hand-held dynamometer and data regarding the body composition. [Subjects and Methods] Measurement was performed in 21 healthy males in their twenties to thirties. Single regression analysis was performed, with measurement values representing 1RM and the maximal isometric muscle strength as dependent and independent variables, respectively. Furthermore, multiple regression analysis was performed, with data regarding the body composition incorporated as another independent variable, in addition to the maximal isometric muscle strength. [Results] Through single regression analysis with the maximal isometric muscle strength as an independent variable, the following regression formula was created: 1RM (kg)=0.714 + 0.783 × maximal isometric muscle strength (kgf). On multiple regression analysis, only the total muscle mass was extracted. [Conclusion] A highly accurate regression formula to estimate 1RM was created based on both the maximal isometric muscle strength and body composition. Using a hand-held dynamometer and body composition analyzer, it was possible to measure these items in a short time, and obtain clinically useful results.

  16. Importance of length and sequence order on magnesium binding to surface-bound oligonucleotides studied by second harmonic generation and atomic force microscopy.

    Science.gov (United States)

    Holland, Joseph G; Geiger, Franz M

    2012-06-07

    The binding of magnesium ions to surface-bound single-stranded oligonucleotides was studied under aqueous conditions using second harmonic generation (SHG) and atomic force microscopy (AFM). The effect of strand length on the number of Mg(II) ions bound and their free binding energy was examined for 5-, 10-, 15-, and 20-mers of adenine and guanine at pH 7, 298 K, and 10 mM NaCl. The binding free energies for adenine and guanine sequences were calculated to be -32.1(4) and -35.6(2) kJ/mol, respectively, and invariant with strand length. Furthermore, the ion density for adenine oligonucleotides did not change as strand length increased, with an average value of 2(1) ions/strand. In sharp contrast, guanine oligonucleotides displayed a linear relationship between strand length and ion density, suggesting that cooperativity is important. This data gives predictive capabilities for mixed strands of various lengths, which we exploit for 20-mers of adenines and guanines. In addition, the role sequence order plays in strands of hetero-oligonucleotides was examined for 5'-A(10)G(10)-3', 5'-(AG)(10)-3', and 5'-G(10)A(10)-3' (here the -3' end is chemically modified to bind to the surface). Although the free energy of binding is the same for these three strands (averaged to be -33.3(4) kJ/mol), the total ion density increases when several guanine residues are close to the 3' end (and thus close to the solid support substrate). To further understand these results, we analyzed the height profiles of the functionalized surfaces with tapping-mode atomic force microscopy (AFM). When comparing the average surface height profiles of the oligonucleotide surfaces pre- and post- Mg(II) binding, a positive correlation was found between ion density and the subsequent height decrease following Mg(II) binding, which we attribute to reductions in Coulomb repulsion and strand collapse once a critical number of Mg(II) ions are bound to the strand.

  17. Standardized voluntary force measurement in a lower extremity rehabilitation robot

    Directory of Open Access Journals (Sweden)

    Bolliger Marc

    2008-10-01

    Full Text Available Abstract Background Isometric force measurements in the lower extremity are widely used in rehabilitation of subjects with neurological movement disorders (NMD because walking ability has been shown to be related to muscle strength. Therefore muscle strength measurements can be used to monitor and control the effects of training programs. A new method to assess isometric muscle force was implemented in the driven gait orthosis (DGO Lokomat. To evaluate the capabilities of this new measurement method, inter- and intra-rater reliability were assessed. Methods Reliability was assessed in subjects with and without NMD. Subjects were tested twice on the same day by two different therapists to test inter-rater reliability and on two separate days by the same therapist to test intra-rater reliability. Results Results showed fair to good reliability for the new measurement method to assess isometric muscle force of lower extremities. In subjects without NMD, intraclass correlation coefficients (ICC for inter-rater reliability ranged from 0.72 to 0.97 and intra-rater reliability from 0.71 to 0.90. In subjects with NMD, ICC ranged from 0.66 to 0.97 for inter-rater and from 0.50 to 0.96 for intra-rater reliability. Conclusion Inter- and intra- rater reliability of an assessment method for measuring maximal voluntary isometric muscle force of lower extremities was demonstrated. We suggest that this method is a valuable tool for documentation and controlling of the rehabilitation process in patients using a DGO.

  18. Trunk muscle fatigue during a lateral isometric hold test: what are we evaluating?

    Directory of Open Access Journals (Sweden)

    Pagé Isabelle

    2012-04-01

    Full Text Available Abstract Background Side bridge endurance protocols have been suggested to evaluate lateral trunk flexor and/or spine stabilizer muscles. To date, no study has investigated muscle recruitment and fatigability during these protocols. Therefore the purpose of our study was to quantify fatigue parameters in various trunk muscles during a modified side bridge endurance task (i.e. a lateral isometric hold test on a 45° roman chair apparatus and determine which primary trunk muscles get fatigued during this task. It was hypothesized that the ipsilateral external oblique and lumbar erector spinae muscles will exhibit the highest fatigue indices. Methods Twenty-two healthy subjects participated in this study. The experimental session included left and right lateral isometric hold tasks preceded and followed by 3 maximal voluntary contractions in the same position. Surface electromyography (EMG recordings were obtained bilaterally from the external oblique, rectus abdominis, and L2 and L5 erector spinae. Statistical analysis were conducted to compare the right and left maximal voluntary contractions (MVC, surface EMG activities, right vs. left holding times and decay rate of the median frequency as the percent change from the initial value (NMFslope. Results No significant left and right lateral isometric hold tests differences were observed neither for holding times (97.2 ± 21.5 sec and 96.7 ± 24.9 sec respectively nor for pre and post fatigue root mean square during MVCs. However, participants showed significant decreases of MVCs between pre and post fatigue measurements for both the left and right lateral isometric hold tests. Statistical analysis showed that a significantly NMFslope of the ipsilateral external oblique during both conditions, and a NMFslope of the contralateral L5 erector spinae during the left lateral isometric hold test were steeper than those of the other side’s respective muscles. Although some participants

  19. Timing differences in the generation of ground reaction forces between the initial and secondary landing phases of the drop vertical jump ☆

    Science.gov (United States)

    Bates, Nathaniel A.; Ford, Kevin R.; Myer, Gregory D.; Hewett, Timothy E.

    2014-01-01

    Background Rapid impulse loads imparted on the lower extremity from ground contact when landing from a jump may contribute to ACL injury prevalence in female athletes. The drop jump and drop landing tasks enacted in the first and second landings of drop vertical jumps, respectively, have been shown to elicit separate neuromechanical responses. We examined the first and second landings of a drop vertical jump for differences in landing phase duration, time to peak force, and rate of force development. Methods 239 adolescent female basketball players completed drop vertical jumps from an initial height of 31 cm. In-ground force platforms and a three dimensional motion capture system recorded force and positional data for each trial. Findings Between the first and second landing, rate of force development experienced no change (P > 0.62), landing phase duration decreased (P = 0.01), and time to peak ground reaction force increased (P 0.12). Interpretation The current results have important implications for the future assessment of ACL injury risk behaviors. Rate of force development remained unchanged between first and second landings from equivalent fall height, while time to peak reaction force increased during the second landing. Neither factor was dependent on the total time duration of landing phase, which decreased during the second landing. Shorter time to peak force may increase ligament strain and better represent the abrupt joint loading that is associated with ACL injury risk. PMID:23899938

  20. Timing differences in the generation of ground reaction forces between the initial and secondary landing phases of the drop vertical jump.

    Science.gov (United States)

    Bates, Nathaniel A; Ford, Kevin R; Myer, Gregory D; Hewett, Timothy E

    2013-08-01

    Rapid impulse loads imparted on the lower extremity from ground contact when landing from a jump may contribute to ACL injury prevalence in female athletes. The drop jump and drop landing tasks enacted in the first and second landings of drop vertical jumps, respectively, have been shown to elicit separate neuromechanical responses. We examined the first and second landings of a drop vertical jump for differences in landing phase duration, time to peak force, and rate of force development. 239 adolescent female basketball players completed drop vertical jumps from an initial height of 31cm. In-ground force platforms and a three dimensional motion capture system recorded force and positional data for each trial. Between the first and second landing, rate of force development experienced no change (P>0.62), landing phase duration decreased (P=0.01), and time to peak ground reaction force increased (P0.12). The current results have important implications for the future assessment of ACL injury risk behaviors. Rate of force development remained unchanged between first and second landings from equivalent fall height, while time to peak reaction force increased during the second landing. Neither factor was dependent on the total time duration of landing phase, which decreased during the second landing. Shorter time to peak force may increase ligament strain and better represent the abrupt joint loading that is associated with ACL injury risk. © 2013.

  1. Isometric handgrip does not elicit cardiovascular overload or post-exercise hypotension in hypertensive older women

    Directory of Open Access Journals (Sweden)

    Olher RR

    2013-06-01

    Full Text Available Rafael dos Reis Vieira Olher,1,2,* Danilo Sales Bocalini,3,* Reury Frank Bacurau,4 Daniel Rodriguez,5 Aylton Figueira Jr,5 Francisco Luciano Pontes Jr,4 Francisco Navarro,6 Herbert Gustavo Simões,1 Ronaldo Carvalho Araujo,7 Milton Rocha Moraes8 1Universidade Católica de Brasília, Distrito Federal, 2Universidade Gama Filho, Rio de Janeiro, 3Universidade Nove de Julho (UNINOVE, São Paulo, 4Universidade de São Paulo – Escola de Artes, Ciências e Humanidades, São Paulo, 5Universidade São Judas Tadeu (USJT, São Paulo, Brazil, 6Universidade Federal do Maranhão, Maranhão, 7Universidade de São Paulo, Instituto de Ciências Biomédicas, São Paulo, 8Universidade Federal de São Paulo – Escola Paulista de Medicina, São Paulo, Brazil *These authors contributed equally to this work Background: Arterial hypertension is a serious health problem affecting mainly the elderly population. Recent studies have considered both aerobic and resistance exercises as a non-pharmacological aid for arterial hypertension treatment. However, the cardiovascular responses of the elderly to isometric resistance exercise (eg, isometric handgrip [IHG] have not yet been documented. Objective: The purpose of this study was to investigate cardiovascular responses to different intensities of isometric exercise, as well as the occurrence of post-isometric exercise hypotension in hypertensive elderly people under antihypertensive medication treatment. Patients and methods: Twelve women volunteered to participate in the study after a maximal voluntary contraction test (MVC and standardization of the intervention workload consisting of two sessions of IHG exercise performed in four sets of five contractions of a 10-second duration. Sessions were performed both at 30% of the MVC and 50% of the MVC, using a unilateral IHG protocol. Both intensities were compared with a control session without exercise. Systolic blood pressure (SBP and diastolic blood pressure (DBP at rest

  2. On the higher order derivatives in the laws of motion and their application to an active force generator and to condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lahdelma, S.

    1995-12-31

    The current paper commences with a review of the history of classical mechanics. The problems connected with condition monitoring and the construction of high-speed machines are so difficult that a knowledge of the fundamentals of mechanics is essential for solving them. It is thus natural that careful attention should be paid to the starting points and assumptions upon which earlier measurement and calculation methods have relied, for it is only after this than one can deduce whether certain simplifications are due to inadequate measurement technology, inflexibility of ideas, a level of precision that is restricted to simple applications or efforts towards simple models merely in order to avoid calculation work. The historical section contains citations from the original sources, which will be useful for those wishing to examine the topic in more detail. The actual textual part is written in such a way that the fundamental content of the works quoted becomes clear even though not all the individual points are translated word for word. The general practice of utilizing the original notations is observed in this section. The paper contains a new way of deriving the laws of motion in classical mechanics from the fundamental law presented in Section 3. Original sources are employed in interpretations regarding terminology, particularly in the case of Lagrange`s function and Hamilton`s principle. The experimental section involves an examination of a two-particle system composed of an active force generator controlled by the first and second time derivatives of the accelerations and by the fractional time derivatives of the particles. This also enables resonance vibrations to be reduced considerably and highly stable solutions to be found

  3. Clap and Fling Interaction of Bristled Wings: Effects of Varying Reynolds Number and Bristle Spacing on Force Generation and Flow Structures

    Science.gov (United States)

    Kasoju, Vishwa Teja

    The smallest flying insects with body lengths under 1 mm, such as thrips and fairyflies, typically show the presence of long bristles on their wings. Thrips have been observed to use wing-wing interaction via 'clap and fling' for flapping flight at low Reynolds number (Re) on the order of 10, where a wing pair comes into close contact at the end of upstroke and fling apart at the beginning of downstroke. We examined the effects of varying the following parameters on force generation and flow structures formed during clap and fling: (1) Re ranging from 5 to 15 for a bristled wing pair (G/D = 17) and a geometrically equivalent solid wing pair; and (2) ratio of spacing between bristles to bristle diameter (G/D) for Re = 10. The G/D ratio in 70 thrips species were quantified from published forewing images. Scaled-up physical models of three bristled wing pairs of varying G/D (5, 11, 17) and a solid wing pair (G/D = 0) were fabricated. A robotic model was used for this study, in which a wing pair was immersed in an aquarium tank filled with glycerin and driven by stepper motors to execute clap and fling kinematics. Dimensionless lift and drag coefficients were determined from strain gauge measurements. Phase-locked particle image velocimetry (PIV) measurements were used to examine flow through the bristles. Chordwise PIV was used to visualize the leading edge vortex (LEV) and trailing edge vortex (TEV) formed over the wings during clap and fling. With increasing G/D, larger reduction was observed in peak drag coefficients as compared to reduction in peak lift coefficients. Net circulation, defined as the difference in circulation (strength) of LEV and TEV, diminished with increasing G/D. Reduction in net circulation resulted in reducing lift generated by bristled wings as compared to solid wings. Leaky, recirculating flow through the bristles provided large drag reduction during fling of a bristled wing pair. If flight efficiency is defined as the ratio of lift to drag

  4. Force transmission in epithelial tissues.

    Science.gov (United States)

    Vasquez, Claudia G; Martin, Adam C

    2016-03-01

    In epithelial tissues, cells constantly generate and transmit forces between each other. Forces generated by the actomyosin cytoskeleton regulate tissue shape and structure and also provide signals that influence cells' decisions to divide, die, or differentiate. Forces are transmitted across epithelia because cells are mechanically linked through junctional complexes, and forces can propagate through the cell cytoplasm. Here, we review some of the molecular mechanisms responsible for force generation, with a specific focus on the actomyosin cortex and adherens junctions. We then discuss evidence for how these mechanisms promote cell shape changes and force transmission in tissues. © 2016 Wiley Periodicals, Inc.

  5. Fluid dynamic forces acting on a circular tube bundle in cross flow. Proposals of generation condition of vortex-induced vibration and correlation equation of turbulence-induced exciting force

    International Nuclear Information System (INIS)

    Inada, Fumio; Yoneda, Kimitoshi; Yasuo, Akira; Nishihara, Takashi

    2000-01-01

    In the circular tube bundle immersed in the crossflow, the exciting force induced by the turbulence and periodically discharged vortices becomes large, and it is necessary to confirm a long-term integrity to the flow induced vibration. In this report, the local fluid exciting force and the correlation length in the direction of tube axis were measured. The exciting force acting on the first row was smaller than that inside the tube bundle, and the exciting force was almost saturated at the third row. As for vortex induced vibration, there could be an influence when a dimensionless frequency was 0.4 or less. When vortex induced vibration did not affect the vibration, a correlation composed of a correlation length and power spectrum density of the local fluid exciting force were proposed, with which we could estimate the amplitude of the vibration. A computer program to estimate the vibration amplitude and maximum stress was made using the flow velocity distribution and the mode of vibration. (author)

  6. The ATP hydrolysis and phosphate release steps control the time course of force development in rabbit skeletal muscle.

    Science.gov (United States)

    Sleep, John; Irving, Malcolm; Burton, Kevin

    2005-03-15

    The time course of isometric force development following photolytic release of ATP in the presence of Ca(2+) was characterized in single skinned fibres from rabbit psoas muscle. Pre-photolysis force was minimized using apyrase to remove contaminating ATP and ADP. After the initial force rise induced by ATP release, a rapid shortening ramp terminated by a step stretch to the original length was imposed, and the time course of the subsequent force redevelopment was again characterized. Force development after ATP release was accurately described by a lag phase followed by one or two exponential components. At 20 degrees C, the lag was 5.6 +/- 0.4 ms (s.e.m., n = 11), and the force rise was well fitted by a single exponential with rate constant 71 +/- 4 s(-1). Force redevelopment after shortening-restretch began from about half the plateau force level, and its single-exponential rate constant was 68 +/- 3 s(-1), very similar to that following ATP release. When fibres were activated by the addition of Ca(2+) in ATP-containing solution, force developed more slowly, and the rate constant for force redevelopment following shortening-restretch reached a maximum value of 38 +/- 4 s(-1) (n = 6) after about 6 s of activation. This lower value may be associated with progressive sarcomere disorder at elevated temperature. Force development following ATP release was much slower at 5 degrees C than at 20 degrees C. The rate constant of a single-exponential fit to the force rise was 4.3 +/- 0.4 s(-1) (n = 22), and this was again similar to that after shortening-restretch in the same activation at this temperature, 3.8 +/- 0.2 s(-1). We conclude that force development after ATP release and shortening-restretch are controlled by the same steps in the actin-myosin ATPase cycle. The present results and much previous work on mechanical-chemical coupling in muscle can be explained by a kinetic scheme in which force is generated by a rapid conformational change bracketed by two

  7. Three-dimensional geometrical changes of the human tibialis anterior muscle and its central aponeurosis measured with three-dimensional ultrasound during isometric contractions

    Directory of Open Access Journals (Sweden)

    Brent J. Raiteri

    2016-07-01

    isovolumetric across contraction conditions and progressively shortened along its line of action as contraction intensity increased. This caused the muscle to bulge centrally, predominantly in thickness, while muscle fascicles shortened and pennation angle increased as a function of contraction intensity. This resulted in central aponeurosis strains in both the transverse and longitudinal directions increasing with contraction intensity. Discussion. 3DUS is a reliable and viable method for quantifying multidirectional muscle and aponeurosis strains during isometric contractions within the same session. Contracting muscle fibres do work in directions along and orthogonal to the muscle’s line of action and central aponeurosis length and width appear to be a function of muscle fascicle shortening and transverse expansion of the muscle fibres, which is dependent on contraction intensity. How factors other than muscle force change the elastic mechanical behaviour of the aponeurosis requires further investigation.

  8. Subatomic forces

    International Nuclear Information System (INIS)

    Sutton, C.

    1989-01-01

    Inside the atom, particles interact through two forces which are never felt in the everyday world. But they may hold the key to the Universe. These ideas on subatomic forces are discussed with respect to the strong force, the electromagnetic force and the electroweak force. (author)

  9. Regular physical exercise improves cardiac autonomic and muscle vasodilatory responses to isometric exercise in healthy elderly

    Directory of Open Access Journals (Sweden)

    Sarmento AO

    2017-06-01

    Full Text Available Adriana de Oliveira Sarmento,1–3 Amilton da Cruz Santos,1,4 Ivani Credidio Trombetta,2,5 Marciano Moacir Dantas,1 Ana Cristina Oliveira Marques,1,4 Leone Severino do Nascimento,1,4 Bruno Teixeira Barbosa,1,2 Marcelo Rodrigues Dos Santos,2 Maria do Amparo Andrade,3 Anna Myrna Jaguaribe-Lima,3,6 Maria do Socorro Brasileiro-Santos1,3,4 1Laboratory of Physical Training Studies Applied to Health, Department of Physical Education, Federal University of Paraiba, João Pessoa, Brazil; 2Unit of Cardiovascular Rehabilitation and Exercise Physiology – Heart Institute (InCor/HC-FMUSP, University of São Paulo, São Paulo, Brazil; 3Graduate Program in Physiotherapy, Federal University of Pernambuco, Recife, Brazil; 4Associate Graduate Program in Physical Education UPE/UFPB, João Pessoa, Brazil; 5Graduate Program in Medicine, Universidade Nove de Julho (UNINOVE, São Paulo, Brazil; 6Department of Morphology and Animal Physiology, Federal Rural University of Pernambuco, Recife, Brazil Abstract: The objective of this study was to evaluate cardiac autonomic control and muscle vasodilation response during isometric exercise in sedentary and physically active older adults. Twenty healthy participants, 10 sedentary and 10 physically active older adults, were evaluated and paired by gender, age, and body mass index. Sympathetic and parasympathetic cardiac activity (spectral and symbolic heart rate analysis and muscle blood flow (venous occlusion plethysmography were measured for 10 minutes at rest (baseline and during 3 minutes of isometric handgrip exercise at 30% of the maximum voluntary contraction (sympathetic excitatory maneuver. Variables were analyzed at baseline and during 3 minutes of isometric exercise. Cardiac autonomic parameters were analyzed by Wilcoxon and Mann–Whitney tests. Muscle vasodilatory response was analyzed by repeated-measures analysis of variance followed by Tukey’s post hoc test. Sedentary older adults had higher cardiac

  10. Effect of functional isometric squats on vertical jump in trained and untrained men.

    Science.gov (United States)

    Berning, Joseph M; Adams, Kent J; DeBeliso, Mark; Sevene-Adams, Patricia G; Harris, Chad; Stamford, Bryant A

    2010-09-01

    Functional isometrics (FIs) combine dynamic and isometric muscle actions and may hyperstimulate the nervous system leading to an enhanced postactivation potentiation (PAP) and improved subsequent performance. The purpose of this study was to investigate the impact of an FI squat on the countermovement vertical jump (CMVJ) in resistance trained and untrained men. Thirteen trained men (age: 22.8 +/- 3.2 years, mass: 90.0 +/- 16.3 kg, and height: 178.9 +/- 7.1 cm) and 8 untrained men (age: 28.5 +/- 5.9 years, mass: 101.5 +/- 23.0 kg, and height: 177.0 +/- 4.8 cm) participated. On separate days, subjects performed CMVJs after 2 different warm-up conditions. The warm-up conditions consisted of either 5 minutes of low-intensity cycling or 5 minutes of low-intensity cycling plus a 3-second FI squat with 150% of their 1 repetition maximum (1RM). A 2 x 3 repeated-measures analysis of variance with Bonferroni post hoc revealed that when comparing the 2 warm-up conditions in the trained subjects, a significant increase (p squat. This increase was maintained when subjects were retested at 5 minutes post (2.6 cm, + 5.5%). No significant difference in CMVJ was detected in the untrained group (p = 0.49). Results support the addition of an FI squat performed at 150% of 1RM to a low-intensity cycling warm-up to enhance PAP in resistance trained but not in untrained men as measured by CMVJ. Practically, adding functional isometrics to a warm-up scheme may significantly enhance acute, short-term power output in resistance trained men.

  11. Neuromuscular Activation of the Vastus Intermedius Muscle during Isometric Hip Flexion.

    Directory of Open Access Journals (Sweden)

    Akira Saito

    Full Text Available Although activity of the rectus femoris (RF differs from that of the other synergists in quadriceps femoris muscle group during physical activities in humans, it has been suggested that the activation pattern of the vastus intermedius (VI is similar to that of the RF. The purpose of present study was to examine activation of the VI during isometric hip flexion. Ten healthy men performed isometric hip flexion contractions at 25%, 50%, 75%, and 100% of maximal voluntary contraction at hip joint angles of 90°, 110° and 130°. Surface electromyography (EMG was used to record activity of the four quadriceps femoris muscles and EMG signals were root mean square processed and normalized to EMG amplitude during an isometric knee extension with maximal voluntary contraction. The normalized EMG was significantly higher for the VI than for the vastus medialis during hip flexion at 100% of maximal voluntary contraction at hip joint angles of 110° and 130° (P < 0.05. The onset of VI activation was 230-240 ms later than the onset of RF activation during hip flexion at each hip joint angle, which was significantly later than during knee extension at 100% of maximal voluntary contraction (P < 0.05. These results suggest that the VI is activated later than the RF during hip flexion. Activity of the VI during hip flexion might contribute to stabilize the knee joint as an antagonist and might help to smooth knee joint motion, such as in the transition from hip flexion to knee extension during walking, running and pedaling.

  12. An investigation of the tri-bar gripping system on isometric muscular endurance.

    Science.gov (United States)

    Drury, Daniel G; Faggiono, Heath; Stuempfle, Kristin J

    2004-11-01

    Recently, a new product called the Tri-Bar has been introduced as an alternative to the standard round weightlifting bar. The Tri-Bar has the same weight, length, and circumference as a standard weightlifting bar and differs only in that the shape of the bar is formed like a triangle with rounded edges. Theoretically, the shape of the bar will enhance gripping comfort and increase muscular endurance. We studied 32 moderately trained males who were free from upper-body injury or limitation. Each participant completed 4 visits to the lab as part of 2 separate investigations. The first investigation was a comparison of straight-arm hang times while grasping a standard Olympic bar or a Tri-Bar attached to the top of a power rack. The second investigation involved grasping a standard revolving cable handle or a Tri-Bar revolving handle attached to a weight equal to half the subject's body weight. In both investigations, time was used as a measure of isometric muscular endurance. Differences were determined using a dependent t-test, and a level of significance was set at p < 0.05. Mean hang times were significantly longer when the men hung from the Tri-Bar (107.6 seconds) versus the standard bar (95.4 seconds) (p = 0.015). Conversely, in the investigation using the revolving handles, the round bar produced longer grasping times (71.5 seconds) than the Tri-Bar (62.6 seconds) (p = 0.000). The results of this investigation indicate that a fixed and stable Tri-Bar may help to increase hang time, but a Tri-Bar free to rotate within the grasp may decrease grasping time in comparison to a standard round handle. With regard to exercises that require isometric grasping, the Tri-Bar may be an effective alternative to the standard bar for increasing isometric grasping endurance.

  13. Effects of a 16-week Pilates exercises training program for isometric trunk extension and flexion strength.

    Science.gov (United States)

    Kliziene, Irina; Sipaviciene, Saule; Vilkiene, Jovita; Astrauskiene, Audrone; Cibulskas, Gintautas; Klizas, Sarunas; Cizauskas, Ginas

    2017-01-01

    To evaluate the effects of Pilates exercises designed to improve isometric trunk extension and flexion strength of muscles in women with chronic low back pain (cLBP). Female volunteers with cLBP were divided into an experimental group (EG; n = 27) and a control group (CG; n = 27). Pilates exercises were performed twice per week by the EG; the duration of each session was 60 min. The program lasted for 16 weeks; thus patients underwent a total of 32 exercise sessions. The maximum isometric waist bending strength of the EG had improved significantly (p = 0.001) after 16 weeks of the Pilates program. The results of trunk flexion muscle endurance tests significantly depended on the trunk extension muscle endurance before the intervention, and at 1 month (r = 0.723, p Pilates exercise program. At the end of the 16-week exercise program, cLBP intensity decreased by 2.01 ± 0.8 (p Pilates exercise program the pain intensified and the functional state deteriorated much faster than the maximum trunk muscle strength. Therefore, it can be concluded that, to decrease pain and improve functional condition, regular exercise (and not only improved strength and endurance) is required. We established that, although the 16-week lumbar stabilization exercise program increased isometric trunk extension and flexion strength and this increase in strength persisted for 2 months, decreased LBP and improved functional condition endured for only 1 month. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Evaluation of isometric strength and fatty infiltration of the subscapularis in latarjet surgery.

    Science.gov (United States)

    Dos Santos, Ricardo Barreto Monteiro; Kauffman, Fábio Neumann; de Lima, Gabriel Praxedes; Ferreira, Avraham Machado Costa; Dos Santos, Saulo Monteiro; Aguiar, José Lamartine de Andrade

    2015-01-01

    To evaluate the function of the subscapularis muscle by means of isometric strength, clinical examination and analysis of fatty infiltration in patients with recurrent anterior dislocation of the shoulder undergoing Latarjet-Patte surgery. 38 patients operated from March 2011 to March 2012, with minimum follow-up of two years were evaluated, being 26 males and 12 females, with a mean age of 28.7 years old. Isometric strength was measured using a portable dynamometer and measuring the distance from the back of the hand during the lift-off test. We used the Rowe and Walch-Duplay scores for clinical evaluation. The degree of fatty infiltration of the subscapularis belly was assessed by computed tomography. The mean scores in the Walch-Duplay and Rowe were 84.7 and 89.4, respectively. The mean distance to the back of the hand was 7.34 cm on the operated side and 8.72 cm on the opposite side (p strength measured in the lift-off test was 0.38 kg lower than on the contralateral side (p = 0.001). There was no fatty infiltration of the subscapularis in 16 patients (42.1%). Sixteen patients (42.1%) were classified as Goutallier grade 1 and six (15.8%) as grade 2. We found that the measured isometric strength decreases with increasing the degree of fatty infiltration (p strength, albeit of low magnitude (0.38 kg), was directly related to the degree of fatty infiltration and worse clinical outcomes. Level of Evidence III, Therapeutic Study - Investigating the Results of Treatment.

  15. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  16. Modulation of Isometric Quadriceps Strength in Soccer Players With Transcranial Direct Current Stimulation: A Crossover Study.

    Science.gov (United States)

    Vargas, Valentine Z; Baptista, Abrahão F; Pereira, Guilherme O C; Pochini, Alberto C; Ejnisman, Benno; Santos, Marcelo B; João, Silvia M A; Hazime, Fuad A

    2018-05-01

    Vargas, VZ, Baptista, AF, Pereira, GOC, Pochini, AC, Ejnisman, B, Santos, MB, João, SMA, and Hazime, FA. Modulation of isometric quadriceps strength in soccer players with transcranial direct current stimulation: a crossover study. J Strength Cond Res 32(5): 1336-1341, 2018-The aim of this study was to evaluate the effect of transcranial direct current stimulation (tDCS) on the maximum isometric muscle contraction (MVIC) of the knee extensors in soccer players at the preprofessional level. Twenty female soccer players aged 15-17 years (mean = 16.1; SD = 0.9) with 5.2 ± 2.6 years of training were randomly divided into 2 groups to receive either active or sham tDCS in a single session (2 mA; 0.057 mA·cm). The MVIC of the knee extensors was evaluated in both lower limbs by manual dynamometry in 5 sets of contractions divided into 4 blocks: (a) prestimulation, (b) during tDCS, (c) 30 minutes after tDCS, and (d) 60 minutes after tDCS. After an interval of 7 days, the groups were evaluated again, and the type of initial stimulation was inverted between participants. The MVIC of the knee extensors increased significantly during active tDCS (dominant limb (DL) = 0.4; IC = 0.1-0.8 N·Kg), 30 minutes after active tDCS (DL = 0.9; IC 0.4-1.4 N·Kg), and 60 minutes after active tDCS (DL = 1.0; IC 0.3-1.6 N·Kg) but not for sham tDCS. Our conclusion was that tDCS temporarily increases isometric quadriceps strength in adolescent female soccer players, which may be useful for both strength training and rehabilitation.

  17. Functional and muscular adaptations in an experimental model for isometric strength training in mice.

    Directory of Open Access Journals (Sweden)

    Karsten Krüger

    Full Text Available Exercise training induces muscular adaptations that are highly specific to the type of exercise. For a systematic study of the differentiated exercise adaptations on a molecular level mouse models have been used successfully. The aim of the current study was to develop a suitable mouse model of isometric strength exercise training characterized by specific adaptations known from strength training. C57BL/6 mice performed an isometric strength training (ST for 10 weeks 5 days/week. Additionally, either a sedentary control group (CT or a regular endurance training group (ET groups were used as controls. Performance capacity was determined by maximum holding time (MHT and treadmill spirometry, respectively. Furthermore, muscle fiber types and diameter, muscular concentration of phosphofructokinase 1 (PFK, succinate dehydrogenase (SDHa, and glucose transporter type 4 (GLUT4 were determined. In a further approach, the effect of ST on glucose intolerance was tested in diabetic mice. In mice of the ST group we observed an increase of MHT in isometric strength tests, a type II fiber hypertrophy, and an increased GLUT4 protein content in the membrane fraction. In contrast, in mice of the ET group an increase of VO(2max, a shift to oxidative muscle fiber type and an increase of oxidative enzyme content was measured. Furthermore strength training was effective in reducing glucose intolerance in mice fed a high fat diet. An effective murine strength training model was developed and evaluated, which revealed marked differences in adaptations known from endurance training. This approach seems also suitable to test for therapeutical effects of strength training.

  18. Comparison of regression models for estimation of isometric wrist joint torques using surface electromyography

    Directory of Open Access Journals (Sweden)

    Menon Carlo

    2011-09-01

    Full Text Available Abstract Background Several regression models have been proposed for estimation of isometric joint torque using surface electromyography (SEMG signals. Common issues related to torque estimation models are degradation of model accuracy with passage of time, electrode displacement, and alteration of limb posture. This work compares the performance of the most commonly used regression models under these circumstances, in order to assist researchers with identifying the most appropriate model for a specific biomedical application. Methods Eleven healthy volunteers participated in this study. A custom-built rig, equipped with a torque sensor, was used to measure isometric torque as each volunteer flexed and extended his wrist. SEMG signals from eight forearm muscles, in addition to wrist joint torque data were gathered during the experiment. Additional data were gathered one hour and twenty-four hours following the completion of the first data gathering session, for the purpose of evaluating the effects of passage of time and electrode displacement on accuracy of models. Acquired SEMG signals were filtered, rectified, normalized and then fed to models for training. Results It was shown that mean adjusted coefficient of determination (Ra2 values decrease between 20%-35% for different models after one hour while altering arm posture decreased mean Ra2 values between 64% to 74% for different models. Conclusions Model estimation accuracy drops significantly with passage of time, electrode displacement, and alteration of limb posture. Therefore model retraining is crucial for preserving estimation accuracy. Data resampling can significantly reduce model training time without losing estimation accuracy. Among the models compared, ordinary least squares linear regression model (OLS was shown to have high isometric torque estimation accuracy combined with very short training times.

  19. Systemic Exercise-Induced Hypoalgesia Following Isometric Exercise Reduces Conditioned Pain Modulation.

    Science.gov (United States)

    Alsouhibani, Ali; Vaegter, Henrik Bjarke; Hoeger Bement, Marie

    2018-04-03

    Physically active individuals show greater conditioned pain modulation (CPM) compared with less active individuals. Understanding the effects of acute exercise on CPM may allow for a more targeted use of exercise in the management of pain. This study investigated the effects of acute isometric exercise on CPM. In addition, the between-session and within-session reliability of CPM was investigated. Experimental, randomized crossover study. Laboratory at Marquette University. Thirty healthy adults (19.3±1.5 years, 15 males). Subjects underwent CPM testing before and after isometric exercise (knee extension, 30% maximum voluntary contraction for three minutes) and quiet rest in two separate experimental sessions. Pressure pain thresholds (PPTs) at the quadriceps and upper trapezius muscles were assessed before, during, and after ice water immersions. PPTs increased during ice water immersion (i.e., CPM), and quadriceps PPT increased after exercise (P CPM decreased similarly following exercise and quiet rest (P > 0.05). CPM within-session reliability was fair to good (intraclass correlation coefficient [ICC] = 0.43-0.70), and the between-session reliability was poor (ICC = 0.20-0.35). Due to the variability in the systemic exercise-induced hypoalgesia (EIH) response, participants were divided into systemic EIH responders (N = 9) and nonresponders (N = 21). EIH responders experienced attenuated CPM following exercise (P = 0.03), whereas the nonresponders showed no significant change (P > 0.05). Isometric exercise decreased CPM in individuals who reported systemic EIH, suggesting activation of shared mechanisms between CPM and systemic EIH responses. These results may improve the understanding of increased pain after exercise in patients with chronic pain and potentially attenuated CPM.

  20. The Validity and Responsiveness of Isometric Lower Body Multi-Joint Tests of Muscular Strength: a Systematic Review.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2017-12-01

    Researchers and practitioners working in sports medicine and science require valid tests to determine the effectiveness of interventions and enhance understanding of mechanisms underpinning adaptation. Such decision making is influenced by the supportive evidence describing the validity of tests within current research. The objective of this study is to review the validity of lower body isometric multi-joint tests ability to assess muscular strength and determine the current level of supporting evidence. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed in a systematic fashion to search, assess and synthesize existing literature on this topic. Electronic databases such as Web of Science, CINAHL and PubMed were searched up to 18 March 2015. Potential inclusions were screened against eligibility criteria relating to types of test, measurement instrument, properties of validity assessed and population group and were required to be published in English. The Consensus-based Standards for the Selection of health Measurement Instruments (COSMIN) checklist was used to assess methodological quality and measurement property rating of included studies. Studies rated as fair or better in methodological quality were included in the best evidence synthesis. Fifty-nine studies met the eligibility criteria for quality appraisal. The ten studies that rated fair or better in methodological quality were included in the best evidence synthesis. The most frequently investigated lower body isometric multi-joint tests for validity were the isometric mid-thigh pull and isometric squat. The validity of each of these tests was strong in terms of reliability and construct validity. The evidence for responsiveness of tests was found to be moderate for the isometric squat test and unknown for the isometric mid-thigh pull. No tests using the isometric leg press met the criteria for inclusion in the best evidence synthesis. Researchers and

  1. Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study

    OpenAIRE

    Ueno, Ryo; Ishida, Tomoya; Yamanaka, Masanori; Taniguchi, Shohei; Ikuta, Ryohei; Samukawa, Mina; Saito, Hiroshi; Tohyama, Harukazu

    2017-01-01

    Background: Although it is well known that quadriceps force generates anterior tibial force, it has been unclear whether quadriceps force causes great anterior tibial force during the early phase of a landing task. The purpose of the present study was to examine whether the quadriceps force induced great anterior tibial force during the early phase of a landing task. Methods: Fourteen young, healthy, female subjects performed a single-leg landing task. Muscle force and anterior tibial force w...

  2. The effects of athletics training on isometric strength and EMG activity in adolescent athletes

    OpenAIRE

    NIKOLAOS AGGELOUSIS; NIKOLAOS MANTZOURANIS; THEOPHILOS PILIANIDIS; GEORGIOS DASTERIDIS

    2012-01-01

    The aim of this study was to evaluate the effect of two different training programs on electromyographic activity (EMG), isometric strength and quadriceps hypertrophy in track and field athletes. 27 male adolescents athletes were divided in three (3) groups of nine (9), the Neuromuscular Group (NeuroGr), the Hypertrophy Group (HyperGr) and the Control Group (ControlG). The participants in both NeuroGr and HyperGr trained 3 times per week for 8 weeks while the athletes’of ControlGr did not tak...

  3. Computerized analysis of isometric tension studies provides important additional information about vasomotor activity

    Directory of Open Access Journals (Sweden)

    Vincent M.B.

    1997-01-01

    Full Text Available Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail

  4. Weathering reactions and isometric log-ratio coordinates: Do they speak to each other?

    International Nuclear Information System (INIS)

    Buccianti, Antonella; Zuo, Renguang

    2016-01-01

    The aim of this contribution is to explore the relationship among some concepts, often considered to be unrelated, such as weathering reactions, compositional data and fractals by means of distribution analysis. Weathering reactions represent the necessary transfer of heat and entropy to the environment in geochemical cycles. Compositional data express the relative abundance of chemical elements/species in a given total (i.e. volume or weight). Fractals are temporal or spatial objects with self-similarity and scale-invariance, so that internal structures repeat themselves over multiple levels of magnification or scales of measurement. Gibbs's free energy and the application of the Law Mass Action can be used to model weathering reactions, under the hypothesis of chemical equilibrium. Compositional data are obtained in the analytical phase after the determination of the concentrations of chemicals in sampled solid, liquid or gaseous materials. Fractals can be measured by using their fractal dimensions. In this paper, the presence of fractal structures is observed when the frequency distribution of isometric log-ratio coordinates is investigated, showing the logarithm of the cumulative number of samples exceeding a certain coordinate value plotted against the coordinate value itself. Isometric log-ratio coordinates (or balances) were constructed by using the sequential binary partition (SBP) method. The balances were identified to maintain, as far as possible, the similarity with a corresponding weathering reaction affecting the Arno river catchment (Tuscany, central Italy) as described by the Law of Mass Action. The emergence of fractal structures indicates the presence of dissipative systems, which require complexity, large numbers of inter-connected elements and stochasticity. - Highlights: • Frequency distribution analysis links compositional data and fractals. • Isometric log-ratio coordinates simulate chemical reactions in weathering processes. • Fractal

  5. Plyometric training improves voluntary activation and strength during isometric, concentric and eccentric contractions.

    Science.gov (United States)

    Behrens, Martin; Mau-Moeller, Anett; Mueller, Karoline; Heise, Sandra; Gube, Martin; Beuster, Nico; Herlyn, Philipp K E; Fischer, Dagmar-C; Bruhn, Sven

    2016-02-01

    This study investigated effects of plyometric training (6 weeks, 3 sessions/week) on maximum voluntary contraction (MVC) strength and neural activation of the knee extensors during isometric, concentric and eccentric contractions. Twenty-seven participants were randomly assigned to the intervention or control group. Maximum voluntary torques (MVT) during the different types of contraction were measured at 110° knee flexion (180°=full extension). The interpolated twitch technique was applied at the same knee joint angle during isometric, concentric and eccentric contractions to measure voluntary activation. In addition, normalized root mean square of the EMG signal at MVT was calculated. The twitch torque signal induced by electrical nerve stimulation at rest was used to evaluate training-related changes at the muscle level. In addition, jump height in countermovement jump was measured. After training, MVT increased by 20Nm (95% CI: 5-36Nm, P=0.012), 24Nm (95% CI: 9-40Nm, P=0.004) and 27Nm (95% CI: 7-48Nm, P=0.013) for isometric, concentric and eccentric MVCs compared to controls, respectively. The strength enhancements were associated with increases in voluntary activation during isometric, concentric and eccentric MVCs by 7.8% (95% CI: 1.8-13.9%, P=0.013), 7.0% (95% CI: 0.4-13.5%, P=0.039) and 8.6% (95% CI: 3.0-14.2%, P=0.005), respectively. Changes in the twitch torque signal of the resting muscle, induced by supramaximal electrical stimulation of the femoral nerve, were not observed, indicating no alterations at the muscle level, whereas jump height was increased. Given the fact that the training exercises consisted of eccentric muscle actions followed by concentric contractions, it is in particular relevant that the plyometric training increased MVC strength and neural activation of the quadriceps muscle regardless of the contraction mode. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Relationship of moderate and low isometric lumbar extension through architectural and muscular activity variables: a cross sectional study

    International Nuclear Information System (INIS)

    Cuesta-Vargas, Antonio I; Gonzalez-Sanchez, Manuel

    2013-01-01

    No study relating the changes obtained in the architecture of erector spinae (ES) muscle were registered with ultrasound and different intensities of muscle contraction recorded by surface EMG (electromyography) on the ES muscle was found. The aim of this study was analyse the relationship in the response of the ES muscle during isometric moderate and light lumbar isometric extension considering architecture and functional muscle variables. Cross-sectional study. 46 subjects (52% men) with a group mean age of 30.4 (±7.78). The participants developed isometric lumbar extension while performing moderate and low isometric trunk and hip extension in a sitting position with hips flexed 90 degrees and the lumbar spine in neutral position. During these measurements, electromyography recordings and ultrasound images were taken bilaterally. Bilaterally pennation angle, muscle thickness, torque and muscle activation were measured. This study was developed at the human movement analysis laboratory of the Health Science Faculty of the University of Malaga (Spain). Strong and moderate correlations were found at moderate and low intensities contraction between the variable of the same intensity, with correlation values ranging from 0.726 (Torque Moderate – EMG Left Moderate) to 0.923 (Angle Left Light – Angle Right Light) (p < 0.001). This correlation is observed between the variables that describe the same intensity of contraction, showing a poor correlation between variables of different intensities. There is a strong relationship between architecture and function variables of ES muscle when describe an isometric lumbar extension at light or moderate intensity

  7. Isometric stress in cardiovascular magnetic resonance - a simple and easily replicable method of assessing cardiovascular differences not apparent at rest

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Kristian H.; Jones, Alexander; Steeden, Jennifer A.; Taylor, Andrew M.; Muthurangu, Vivek [UCL Centre for Cardiovascular MR, UCL Institute of Cardiovascular Science, Level 6 Old Nurses Home, Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London (United Kingdom)

    2016-04-15

    Isometric exercise may unmask cardiovascular disease not evident at rest, and cardiovascular magnetic resonance (CMR) imaging is proven for comprehensive resting assessment. This study devised a simple isometric exercise CMR methodology and assessed the hemodynamic response evoked by isometric exercise. A biceps isometric exercise technique was devised for CMR, and 75 healthy volunteers were assessed at rest, after 3-minute biceps exercise, and 5-minute of recovery using: (1) blood pressure (BP) and (2) CMR measured aortic flow and left ventricular function. Total peripheral resistance (SVR) and arterial compliance (TAC), cardiac output (CO), left ventricular volumes and function (ejection fraction, stroke volume, power output), blood pressure (BP), heart rate (HR), and rate pressure product were assessed at all time points. Image quality was preserved during stress. During exercise there were increases in CO (+14.9 %), HR (+17.0 %), SVR (+9.8 %), systolic BP (+22.4 %), diastolic BP (+25.4 %) and mean BP (+23.2 %). In addition, there were decreases in TAC (-22.0 %) and left ventricular ejection fraction (-6.3 %). Age and body mass index modified the evoked response, even when resting measures were similar. Isometric exercise technique evokes a significant cardiovascular response in CMR, unmasking physiological differences that are not apparent at rest. (orig.)

  8. Isometric stress in cardiovascular magnetic resonance - a simple and easily replicable method of assessing cardiovascular differences not apparent at rest

    International Nuclear Information System (INIS)

    Mortensen, Kristian H.; Jones, Alexander; Steeden, Jennifer A.; Taylor, Andrew M.; Muthurangu, Vivek

    2016-01-01

    Isometric exercise may unmask cardiovascular disease not evident at rest, and cardiovascular magnetic resonance (CMR) imaging is proven for comprehensive resting assessment. This study devised a simple isometric exercise CMR methodology and assessed the hemodynamic response evoked by isometric exercise. A biceps isometric exercise technique was devised for CMR, and 75 healthy volunteers were assessed at rest, after 3-minute biceps exercise, and 5-minute of recovery using: (1) blood pressure (BP) and (2) CMR measured aortic flow and left ventricular function. Total peripheral resistance (SVR) and arterial compliance (TAC), cardiac output (CO), left ventricular volumes and function (ejection fraction, stroke volume, power output), blood pressure (BP), heart rate (HR), and rate pressure product were assessed at all time points. Image quality was preserved during stress. During exercise there were increases in CO (+14.9 %), HR (+17.0 %), SVR (+9.8 %), systolic BP (+22.4 %), diastolic BP (+25.4 %) and mean BP (+23.2 %). In addition, there were decreases in TAC (-22.0 %) and left ventricular ejection fraction (-6.3 %). Age and body mass index modified the evoked response, even when resting measures were similar. Isometric exercise technique evokes a significant cardiovascular response in CMR, unmasking physiological differences that are not apparent at rest. (orig.)

  9. Response of Coagulation Indices to Two Types of Exercise of Eccentric and Isometric in Male Bodybuilding Athletes

    Directory of Open Access Journals (Sweden)

    Maryam Azimpour

    2016-05-01

    Full Text Available Abstract Background and Objectives: Although activation of blood coagulation system in response to physical activity has been identified to some extent, but the contribution of eccentric activity in comparison with isometric activity as resistance exercise, is not clear yet. Therefore, this research was carried out with the purpose of investigating the effect of one session of eccentric and isometric resistance exercise on some coagulation factors in male bodybuilders. Methods: In this semi-experimental study, 28 volunteers were randomly selected from male bodybuilders and divided into two experimental groups and one control group. One of the experimental groups performed eccentric exercise [controlled return (extension of the elbow flexion movement involving an eccentric contraction] and another group performed isometric exercises (holding barbell while flexing elbows at 45 degrees. In order to assess coagulation indices, blood sampling was performed 15 minutes before and immediately after the exercise. Results: Thromboplastin and prothrombin times did not significantly change immediately after the exercise, but the number of platelets significantly increased in both isometric and eccentric types of exercise immediately after the exercise. Conclusion: The results of isometric and eccentric acute resistance exercise showed that the exercise had no negative impact on blood coagulation factors, and increased coagulation system activity reflects the increased number of platelets. The difference between the results of researches carried out in this direction can be resulted from the difference between the exercise protocols, methods and measurement time, and level of preparedness of the participants in the research.

  10. Association between isometric muscle strength and gait joint kinetics in adolescents and young adults with cerebral palsy.

    Science.gov (United States)

    Dallmeijer, A J; Baker, R; Dodd, K J; Taylor, N F

    2011-03-01

    The purpose of this study was to determine the association between isometric muscle strength of the lower limbs and gait joint kinetics in adolescents and young adults with cerebral palsy (CP). Twenty-five participants (11 males) with bilateral spastic CP, aged 14-22 years (mean: 18.9, sd: 2.0 yr) and Gross Motor Function Classification System (GMFCS) level II (n=19) and III (n=6) were tested. Hand held dynamometry was used to measure isometric strength (expressed in Nm/kg) of the hip, knee, and ankle muscles using standardized testing positions and procedures. 3D gait analysis was performed with a VICON system to calculate joint kinetics in the hip, knee and ankle during gait. Ankle peak moments exceeded by far the levels of isometric strength of the plantar flexors, while the knee and hip peak moments were just at or below maximal isometric strength of knee and hip muscles. Isometric muscle strength showed weak to moderate correlations with peak ankle and hip extension moment and power during walking. Despite considerable muscle weakness, joint moment curves were similar to norm values. Results suggest that passive stretch of the muscle-tendon complex of the triceps surae contributes to the ankle moment during walking and that muscle strength assessment may provide additional information to gait kinetics. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Is a sphygmomanometer a valid and reliable tool to measure the isometric strength of hip muscles? A systematic review.

    Science.gov (United States)

    Toohey, Liam Anthony; De Noronha, Marcos; Taylor, Carolyn; Thomas, James

    2015-02-01

    Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength. To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles. A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool. A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer. The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.

  12. The Influence of Swirl Brakes and a Tip Discharge Orifice on the Rotordynamic Forces Generated by Discharge-to-Suction Leakage Flows in Shrouded Centrifugal Pumps

    Science.gov (United States)

    Sivo, Joseph M.; Acosta, A. J.; Brennen, C. E.; Caughey, T. K.

    1993-01-01

    Recent experiments conducted in the Rotor Force Test Facility at the California Institute of Technology have examined the effects of a tip leakage restriction and swirl brakes on the rotordynamic forces due to leakage flows on an impeller undergoing a prescribed circular whirl. The experiments simulate the leakage flow conditions and geometry of the Alternate Turbopump Design (ATD) of the Space Shuttle High Pressure Oxygen Turbopump and are critical to evaluating the pump's rotordynamic instability problems. Previous experimental and analytical results have shown that discharge-to-suction leakage flows in the annulus of a shrouded centrifugal pump contribute substantially to the fluid induced rotordynamic forces. Also, previous experiments have shown that leakage inlet (pump discharge) swirl can increase the cross-coupled stiffness coefficient and hence increase the range of positive whirl for which the tangential force is destabilizing. In recent experimental work, the present authors demonstrated that when the swirl velocity within the leakage path is reduced by the introduction of ribs or swirl brakes, then a substantial decrease in both the destabilizing normal and tangential forces could be achieved. Motivation for the present research is that previous experiments have shown that restrictions such as wear rings or orifices at pump inlets affect the leakage forces. Recent pump designs such as the Space Shuttle Alternate Turbopump Design (ATD) utilize tip orifices at discharge for the purpose of establishing axial thrust balance. The ATD has experienced rotordynamic instability problems and one may surmise that these tip discharge orifices may also have an important effect on the normal and tan