WorldWideScience

Sample records for isolated aorta rings

  1. Effects of thapsigargin in isolated rat thoracic aorta

    DEFF Research Database (Denmark)

    Mikkelsen, E O; Thastrup, Ole; Christensen, S B

    1988-01-01

    The effect of thapsigargin (Tg) was studied in rat thoracic aorta. Tg (10(-8)-10(-5) M) had a dual effect on rat aorta. Thus, Tg induced a concentration dependent increase in basal tone in normal physiological salt solution (PSS), while Tg in potassium (K+) precontracted aortic rings caused a con...... A 23187 had an endothelium dependent relaxant effect on rat aorta different from that of carbachol. The results indicate that Tg in vascular smooth muscle acts by stimulating the transmembranal influx of extracellular calcium....

  2. The Effect of Chlorpyrifos on Isolated Thoracic Aorta in Rats

    Directory of Open Access Journals (Sweden)

    Ebru Yıldırım

    2013-01-01

    Full Text Available This study investigated the effect of chlorpyrifos on thoracic aorta and on the level of NO in plasma and aorta. The effect of chlorpyrifos on thoracic aorta in organ bath was determined in 10 rats. Another 45 rats were assigned to 3 groups with 15 rats each: control group 1 received distilled water, control group 2 was given corn oil, and the last group was given 13.5 mg/kg chlorpyrifos dissolved in corn oil every other day for 8 weeks orally. Chlorpyrifos (10−10 M–10−5 M showed no effect on isolated thoracic aorta. Plasma AChE activity was decreased, while LDH, ALT, GGT, and AST activities were increased in chlorpyrifos group compared to control groups. Plasma NO level was increased in chlorpyrifos group compared to control groups. iNOS expression was present in all groups in the cytoplasm of the endothelia and in the smooth muscle cells of aorta. According to semiquantitative histomorphological analysis, iNOS immunopositive reactions were seen in the decreasing order in chlorpyrifos, control 2, and control 1 groups. eNOS immunopositive reactions were observed in the endothelial cell cytoplasm, rarely in the subintimal layer, and the smooth muscle cells of aorta. There were no differences among the groups in terms of eNOS immunostaining. In conclusion, chlorpyrifos induced NO production in aorta following an increase in NOS expression.

  3. The Effect of Chlorpyrifos on Isolated Thoracic Aorta in Rats

    Science.gov (United States)

    Yıldırım, Ebru; Baydan, Emine; Kanbur, Murat; Kul, Oğuz; Çınar, Miyase; Ekici, Hüsamettin; Atmaca, Nurgül

    2013-01-01

    This study investigated the effect of chlorpyrifos on thoracic aorta and on the level of NO in plasma and aorta. The effect of chlorpyrifos on thoracic aorta in organ bath was determined in 10 rats. Another 45 rats were assigned to 3 groups with 15 rats each: control group 1 received distilled water, control group 2 was given corn oil, and the last group was given 13.5 mg/kg chlorpyrifos dissolved in corn oil every other day for 8 weeks orally. Chlorpyrifos (10−10 M–10−5 M) showed no effect on isolated thoracic aorta. Plasma AChE activity was decreased, while LDH, ALT, GGT, and AST activities were increased in chlorpyrifos group compared to control groups. Plasma NO level was increased in chlorpyrifos group compared to control groups. iNOS expression was present in all groups in the cytoplasm of the endothelia and in the smooth muscle cells of aorta. According to semiquantitative histomorphological analysis, iNOS immunopositive reactions were seen in the decreasing order in chlorpyrifos, control 2, and control 1 groups. eNOS immunopositive reactions were observed in the endothelial cell cytoplasm, rarely in the subintimal layer, and the smooth muscle cells of aorta. There were no differences among the groups in terms of eNOS immunostaining. In conclusion, chlorpyrifos induced NO production in aorta following an increase in NOS expression. PMID:23878805

  4. Arbutus unedo induces endothelium-dependent relaxation of the isolated rat aorta.

    Science.gov (United States)

    Ziyyat, Abderrahim; Mekhfi, Hassane; Bnouham, Mohamed; Tahri, Abdelhafid; Legssyer, Abdelkhaleq; Hoerter, Jacqueline; Fischmeister, Rodolphe

    2002-09-01

    Arbutus unedo L. (Ericaceae) is used in oriental Morocco to treat arterial hypertension. We studied its vasodilator effect and mechanisms of action in vitro. The root aqueous extract of Arbutus (0.25 mg/mL) produced a relaxation of noradrenaline-precontracted ring preparations of rat aorta with intact endothelium. Relaxation by Arbutus did not occur in specimens without endothelium and was inhibited by pretreatment with 100 microM N(G)-methyl-L-arginine (L-NMA), 10 microM methylene blue or 50 microM 1H-[1,2,4] oxadiazolo [4,3-a] quinoxaline-1-one (ODQ) but not by 10 microM atropine. These results suggest that Arbutus produces an endothelium-dependent relaxation of the isolated rat aorta which may be mediated mainly by a stimulation of the endothelial nitric oxide synthase by mechanisms other than activation of muscarinic receptors. Copyright 2002 John Wiley & Sons, Ltd.

  5. Measurement of calcium influx in tethered rings of rabbit aorta under tension

    International Nuclear Information System (INIS)

    Gleason, M.M.; Ratz, P.H.; Flaim, S.F.

    1985-01-01

    Calcium (Ca) influx in vascular smooth muscle is routinely measured in untethered preparations not under passive stretch, and Ca influx data are correlated with data for steady-state isometric tension obtained under parallel conditions from tethered preparations under passive stretch. The validity of this method was tested by simultaneous measurement of Ca influx and tension in tethered rings of rabbit thoracic aorta. Ca influx ( 45 Ca 3-min pulse) and tension were measured at 3 and 30 min after norepinephrine (NE) or KCl and under control (no agonist) conditions. Active tension was significantly altered by variations in passive tension. Ca influx was unaffected by passive tension under control, NE, or KCl conditions, and results were similar at 3 and 30 min. The results confirm the validity of correlating Ca influx data from untethered rings with steady-state contractile response data obtained from tethered rings under similar experimental conditions

  6. Sympatholytic properties of several AT(1)-receptor antagonists in the isolated rabbit thoracic aorta

    NARCIS (Netherlands)

    Nap, Alexander; Balt, Jippe C.; Pfaffendorf, Martin; van Zwieten, Pieter A.

    2002-01-01

    Objective To evaluate the facilitating effect of angiotensin II on sympathetic neurotransmission to quantitatively compare the sympatho-inhibitory potencies of the selective AT(1)-receptor antagonists losartan, irbesartan and telmisartan in the isolated rabbit thoracic aorta. Design To investigate

  7. Effect of prolonged incubation with copper on endothelium-dependent relaxation in rat isolated aorta

    Science.gov (United States)

    Chiarugi, Alberto; Pitari, Giovanni Mario; Costa, Rosa; Ferrante, Margherita; Villari, Loredana; Amico-Roxas, Matilde; Godfraind, Théophile; Bianchi, Alfredo; Salomone, Salvatore

    2002-01-01

    We investigated the effects of prolonged exposure to copper (Cu2+) on vascular functioning of isolated rat aorta. Aortic rings were exposed to CuSO4 (3–24 h) in Dulbecco's modified Eagle medium with or without 10% foetal bovine serum (FBS) and then challenged with vasoconstrictors or vasodilators in the absence of Cu2+. Exposure to 2 μM Cu2+ in the absence of FBS did not modify the response to phenylephrine (PE) or acetylcholine (ACh) in aortic rings incubated for 24 h. Identical exposure in the presence of FBS increased the contractile response to 1 μM PE by 30% (P<0.05) and impaired the relaxant response to 3 μM ACh or 1 μM A23187 (ACh, from 65.7±7.1 to 6.2±1.1%, n=8; A23187, from 74.6±8.2 to 12.0±0.8%, n=6; P<0.01 for both). Cu2+ exposure did not affect the relaxant response to NO-donors. Impairment of vasorelaxation appeared 3 h after incubation with 2 μM Cu2+ and required 12 h to attain a steady state. Vasorelaxation to ACh was partially restored by 1 mM tiron (intracellular scavenger of superoxide ions; maximum relaxation 34.2±6.4%, n=10, P<0.01 vs Cu2+ alone), whereas catalase, superoxide dismutase or cycloheximide were ineffective. Twenty-four hour-exposure to 2 μM Cu2+ did not affect endothelium integrity or eNOS expression, and increased the Cu content in arterial rings from 6.8±1.1 to 18.9±2.9 ng mg−1 wet weight, n=8; P<0.01. Our results show that, in the presence of FBS, prolonged exposure to submicromolar concentrations of Cu2+ impaired endothelium-dependent vasorelaxation in aortic rings, probably through an intracellular generation of superoxide ions. PMID:12163352

  8. 45Ca2+movements induced by Ca2+chloride in isolated rat aorta under K+-free conditions

    NARCIS (Netherlands)

    Wermelskirchen, D.; Nebel, U.; Wirth, A.; Wilffert, B.

    1991-01-01

    Increasing the extracellular Ca2+concentration induced a dihydropyridine-insensitive contraction in the isolated rat aorta bathed in K+-free solution. To obtained further insight into the mechanisms of this contraction45Ca2+uptake measurements were carried out with isolated rat aorta. Increasing the

  9. CA-45(2+) MOVEMENTS INDUCED BY CA2+ CHLORIDE IN ISOLATED RAT AORTA UNDER K+-FREE CONDITIONS

    NARCIS (Netherlands)

    WERMELSKIRCHEN, D; NEBEL, U; WIRTH, A; WILFFERT, B

    1991-01-01

    Increasing the extracellular Ca2+ concentration induced a dihydropyridine-insensitive contraction in the isolated rat aorta bathed in K+-free solution. To obtain further insight into the mechanism of this contraction Ca-45(2+) uptake measurements were carried out with isolated rat aorta. Increasing

  10. Veratridine activates a silent sodium-channel in rat isolated aorta

    NARCIS (Netherlands)

    WERMELSKIRCHEN, D; WILFFERT, B; NEBEL, U; LEIDIG, A; WIRTH, A; Peters, Thies

    1992-01-01

    To investigate the existence of silent Na+ channels, isolated rat aorta was treated with veratridine (0.1 mM) and the resulting Ca2+ uptake was determined. After 30-min incubation the total tissue uptake of Ca2+ and Ca2+ uptake increased from 2.325 +/- 0.017 to 2.614 +/- 0.080 nmol/mg wet weight

  11. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    International Nuclear Information System (INIS)

    Ming, Zhu; Qian, Wang

    2009-01-01

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  12. An isolated left subclavian artery supplied by a collateral artery from the abdominal aorta

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Zhu; Qian, Wang [Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China)

    2009-08-15

    An isolated left subclavian artery is a rare anomaly. We report a 9-month-old boy with an isolated left subclavian artery associated with tetralogy of Fallot and the right aortic arch. MRI and angiography show that the blood supply through the left subclavian artery was maintained by a large tortuous collateral artery from the abdominal aorta. This type of collateral artery structure is unique. (orig.)

  13. Vasodilatory effect of asafoetida essential oil on rat aorta rings: The role of nitric oxide, prostacyclin, and calcium channels.

    Science.gov (United States)

    Esmaeili, Hassan; Sharifi, Mozhdeh; Esmailidehaj, Mansour; Rezvani, Mohammad Ebrahim; Hafizibarjin, Zeynab

    2017-12-01

    Asafoetida is an oleo-gum resin mainly obtained from Ferula assa-foetida L. species in the apiaceae family. Previous studies have shown that it has antispasmodic effects on rat's and pig's ileums. The main goals of this study were to assess the vasodilatory effect of asafoetida essential oil (AEO) on the contractile response of rat's aorta rings and to find the role of nitric oxide, cyclooxygenase, and calcium channels. Thoracic aorta rings were stretched under a steady-state tension of 1 g in an organ bath apparatus for 1 h and then precontracted by KCl (80 mM) in the presence and absence of AEO. L-NAME (blocker of nitric oxide synthase) and indomethacin (blocker of cyclooxygenase) were used to assess the role of nitric oxide (NO) and prostacyclin in the vasodilatory effect of AEO. Also, the effect of AEO on the influx of calcium through the cell membrane calcium channels was determined. Data showed that AEO had vasodilatory effects on aorta rings with both intact (IC 50  = 1.6 µl/l) or denuded endothelium (IC 50  = 19.2 µl/l) with a significantly higher potency in intact endothelium rings. The vasodilatory effects of AEO were reduced, but not completely inhibited, in the presence of L-NAME or indomethacin. Adding AEO to the free-calcium medium also significantly reduced the CaCl 2 -induced contractions. The results indicated that AEO has a potent vasodilatory effect that is endothelium-dependent and endothelium-independent. Also, it reduced the influx of calcium into the cell through plasma membrane calcium channels. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. Differential Kolaviron Attenuated Contractile Responses to Agonists on Isolated Rabbit Aorta in Na+-K+ Pump Blockade.

    Science.gov (United States)

    Uche, O K; Ofeimun, J O

    2017-12-30

    The mechanism of kolaviron-induced vascular smooth muscles (VSMs) responses has not been fullycharacterised. The present study investigated the effect and mode of action of kolaviron a biflavanoid-complex and majorcomponent of Garcinia Kola-fraction on differential contractile responses to agonists-[phenylephrine (PHE) and histamine(HIST)] on VSMs of rabbit isolated aortic rings in K+-free physiological salt solution (KFPSS). Cumulative concentrationresponses to PHE and HIST were examined on 2 mm ring segments of the thoracic aortae which were suspended in 20 mlorgan baths containing physiological salt solution (PSS) for measurement of isometric contractions, at 370C and pH 7.4. Themedium was bubbled with 95% O2, 5% CO2, and rings were given an initial load of 1g. Cumulative contractile responses tothe agonists were studied in normal PSS (control) and following 30 minutes exposure to K+-free PSS and/or 800µg/mLkolaviron. Contractile responses were expressed as percentage of 80 mM K+ contractions in normal PSS. Maximalcontractions (Emax) induced by PHE and HIST compared with high K+ contraction in the various preparations weredifferentially altered following exposure to K+-free or 800µg/mL kolaviron in both intact (+E) and endotheliumdenuded (-E) rings. Based on the efficacy (Emax) and potency (EC50) values for the dose-response curves of the agonists, it isconcluded that enhanced differential contractile responses elicited by agonists in K+-free PSS were significantly attenuatedby kolaviron concentration-dependently. This observation probably suggests the existence of another pathway of kolavironmode of action in vascular smooth muscle reactivity.

  15. Gou-teng (from Uncaria rhynchophylla Miquel)-induced endothelium-dependent and -independent relaxations in the isolated rat aorta.

    Science.gov (United States)

    Kuramochi, T; Chu, J; Suga, T

    1994-01-01

    Gou-teng is a drug used for treatment of hypertension in Chinese medicine. Its antihypertensive action has been previously confirmed in the spontaneously hypertensive rat (SHR). Here, its vasorelaxing effect and the mechanisms of actions were studied in vitro. Gou-teng extract (GTE) relaxed the norepinephrine (NE)-precontracted aortic ring preparations isolated from Wistar Kyoto rats (WKY) with and without intact endothelium; the latter was significantly less sensitive than the former. The GTE-induced endothelium-dependent relaxation was significantly inhibited by NG-monomethyl-L-arginine (NMMA) in a dose-dependent manner while indomethacin did not affect the relaxation. Atropine inhibited the acetylcholine (ACh)-induced endothelium-dependent relaxation but did not the GTE-induced one. Furthermore, once GTE was applied, the following NE-induced contraction was significantly reduced even after repeated washout. NMMA effectively reduced and rather reversed this residual effect of GTE. From these results, it is concluded that GTE relaxes the NE-precontracted rat aorta through endothelium-dependent and, to lesser extent, -independent mechanisms. The endothelium-dependent component would be mediated by EDRF/NO pathway in which the muscarinic cholinoceptors were not involved. Thus, GTE appears to be a potent and long-lasting vasodilator mainly through EDRF/NO release.

  16. "INHIBITORY EFFECT OF ALUMINIUM ON KCL AND PHENYLEPHRINE INDUCED CONTRACTION IN ISOLATED RAT AORTA"

    Directory of Open Access Journals (Sweden)

    T. Mashhoodi

    2004-10-01

    Full Text Available It has been shown in some investigations that cardiovascular events are the main causes of death in hemodialysis patients. The exact etiology is unknown but some of the articles have reported a relation between aluminium ions in the dialysis solution and cardiovascular disorders. To determine the probable effect of aluminium on vasculature function, in vitro effects of aluminium ion on vasoconstriction induced by KCl (30 mM or phenylephrine (10 µM were investigated using isolated rat aorta. AlCl3 (1-4 mM decreased both KCl and phenylephrine induced contractions in a dose dependent manner (P<0.01. Complete inhibition of the contractions occurred using the higher doses of aluminium. Results of this study suggest that because of inhibitory effects of aluminium on vascular contractions, the probable cardiovascular dysfunction must be considered in aluminium intoxication.

  17. Persistent currents in an ensemble of isolated mesoscopic rings

    International Nuclear Information System (INIS)

    Altland, A.; Iida, S.; Mueller-Groelling, A.; Weidenmueller, H.A.

    1992-01-01

    In this work, the authors calculate the persistent current induced at zero temperature by an external, constant, and homogeneous magnetic field in an ensemble of isolated mesoscopic rings. In each ring, the electrons are assumed to move independently under the influence of a Gaussian white noise random impurity potential. They account for the magnetic field only in terms of the flux threading each ring, without considering the field present in the body of the ring. Particular attention is paid to the constraint of integer particle number on each ring. The authors evaluate the persistent current non-perturbatively, using a generating functional involving Grassmann integration. The magnetic flux threading each ring breaks the orthogonal symmetry of the formalism; forcing us to calculate explicitly the orthogonal-unitary crossover. 24 refs., 1 fig

  18. Changes in vascular reactivity induced by acute hyperthyroidism in isolated rat aortae.

    Science.gov (United States)

    Honda, H; Iwata, T; Mochizuki, T; Kogo, H

    2000-06-01

    Hyperthyroidism was induced by subcutaneous injections of L-thyroxine (T(4)) (500 mg/kg/day) for 3 days in order to study whether adrenergic and muscarinic receptor-mediated vascular responses alter at an early stage of the disease. T(4) treatment was sufficient to induce a significant degree of thyroid weight loss, tachycardia, cardiac hypertrophy, and an elevation in serum T(4) levels. The tension of aortic ring preparations isolated from rats was measured isometrically to investigate the influence of acute hyperthyroidism. The contractions induced by norepinephrine (NE) were significantly suppressed in aortic rings from rats treated with T(4) compared with control rats. N(G)-nitro-L-arginine (L-NOARG), an inhibitor of nitric oxide synthase (NOS), significantly enhanced NE-induced contraction in aortic rings from both control and T(4)-treated rats, and the enhancement was greater in rats treated with T(4) than control rats. The relaxations induced by either acetylcholine (ACh) or sodium nitroprusside (SNP) were also significantly enhanced by T(4) treatment. L-NOARG abolished the relaxation induced by ACh in aortic rings from both control and T(4)-treated rats. L-NOARG shifted SNP-induced relaxation curves of aortic rings from those of control rats to the left, but not with rats treated with T(4). T(4) treatment showed no influence on the amount of endothelial NOS (eNOS) protein. These results suggest that vascular responses alter at an early stage of hyperthyroidism and that it may be due to a modification in the NO system which is independent from the amount of eNOS protein.

  19. Harnessing case isolation and ring vaccination to control Ebola.

    Directory of Open Access Journals (Sweden)

    Chad Wells

    2015-05-01

    Full Text Available As a devastating Ebola outbreak in West Africa continues, non-pharmaceutical control measures including contact tracing, quarantine, and case isolation are being implemented. In addition, public health agencies are scaling up efforts to test and deploy candidate vaccines. Given the experimental nature and limited initial supplies of vaccines, a mass vaccination campaign might not be feasible. However, ring vaccination of likely case contacts could provide an effective alternative in distributing the vaccine. To evaluate ring vaccination as a strategy for eliminating Ebola, we developed a pair approximation model of Ebola transmission, parameterized by confirmed incidence data from June 2014 to January 2015 in Liberia and Sierra Leone. Our results suggest that if a combined intervention of case isolation and ring vaccination had been initiated in the early fall of 2014, up to an additional 126 cases in Liberia and 560 cases in Sierra Leone could have been averted beyond case isolation alone. The marginal benefit of ring vaccination is predicted to be greatest in settings where there are more contacts per individual, greater clustering among individuals, when contact tracing has low efficacy or vaccination confers post-exposure protection. In such settings, ring vaccination can avert up to an additional 8% of Ebola cases. Accordingly, ring vaccination is predicted to offer a moderately beneficial supplement to ongoing non-pharmaceutical Ebola control efforts.

  20. Harnessing case isolation and ring vaccination to control Ebola.

    Science.gov (United States)

    Wells, Chad; Yamin, Dan; Ndeffo-Mbah, Martial L; Wenzel, Natasha; Gaffney, Stephen G; Townsend, Jeffrey P; Meyers, Lauren Ancel; Fallah, Mosoka; Nyenswah, Tolbert G; Altice, Frederick L; Atkins, Katherine E; Galvani, Alison P

    2015-05-01

    As a devastating Ebola outbreak in West Africa continues, non-pharmaceutical control measures including contact tracing, quarantine, and case isolation are being implemented. In addition, public health agencies are scaling up efforts to test and deploy candidate vaccines. Given the experimental nature and limited initial supplies of vaccines, a mass vaccination campaign might not be feasible. However, ring vaccination of likely case contacts could provide an effective alternative in distributing the vaccine. To evaluate ring vaccination as a strategy for eliminating Ebola, we developed a pair approximation model of Ebola transmission, parameterized by confirmed incidence data from June 2014 to January 2015 in Liberia and Sierra Leone. Our results suggest that if a combined intervention of case isolation and ring vaccination had been initiated in the early fall of 2014, up to an additional 126 cases in Liberia and 560 cases in Sierra Leone could have been averted beyond case isolation alone. The marginal benefit of ring vaccination is predicted to be greatest in settings where there are more contacts per individual, greater clustering among individuals, when contact tracing has low efficacy or vaccination confers post-exposure protection. In such settings, ring vaccination can avert up to an additional 8% of Ebola cases. Accordingly, ring vaccination is predicted to offer a moderately beneficial supplement to ongoing non-pharmaceutical Ebola control efforts.

  1. Vasorelaxation induced by common edible tropical plant extracts in isolated rat aorta and mesenteric vascular bed.

    Science.gov (United States)

    Runnie, I; Salleh, M N; Mohamed, S; Head, R J; Abeywardena, M Y

    2004-06-01

    In this study, the vasodilatory actions of nine edible tropical plant extracts were investigated. Ipomoea batatas (sweet potato leaf), Piper betle (betel leaf), Anacardium occidentale (cashew leaf), Gynandropsis gynandra (maman leaf), Carica papaya (papaya leaf), and Mentha arvensis (mint leaf) extracts exhibited more than 50% relaxing effect on aortic ring preparations, while Piper betle and Cymbopogon citratus (lemongrass stalk) showed comparable vasorelaxation on isolated perfused mesenteric artery preparation. The vascular effect on the aortic ring preparations were mainly endothelium-dependent, and mediated by nitric oxide (NO) as supported by the inhibition of action in the presence of N(omega)-nitro-L-arginine (NOLA), an nitric oxide synthase (NOS) inhibitor, or by the removal of endothelium. In contrast, vasodilatory actions in resistance vessels (perfused mesenteric vascular beds) appear to involve several biochemical mediators, including NO, prostanoids, and endothelium-dependent hyperpolarizing factors (EDHFs). Total phenolic contents and antioxidant capacities varied among different extracts and found to be independent of vascular relaxation effects. This study demonstrates that many edible plants common in Asian diets to possess potential health benefits, affording protection at the vascular endothelium level.

  2. Tannins and catechin gallate mediate the vasorelaxant effect of Arbutus unedo on the rat isolated aorta.

    Science.gov (United States)

    Legssyer, Abdelkhaleq; Ziyyat, Abderrahim; Mekh, Hassane; Bnouham, Mohamed; Herrenknecht, Christine; Roumy, Vincent; Fourneau, Christophe; Laurens, Alain; Hoerter, Jacqueline; Fischmeister, Rodolphe

    2004-11-01

    This study examined the vascular effect of Arbutus leaves (aqueous extract) and described the isolation of several fractions responsible for their vasorelaxant activity. The aqueous extract (AE) of leaves was tested on rat aortic rings precontracted with 0.1 microm noradrenaline. At 10(-2) g/L, AE produced an endothelium dependent relaxation of 66% +/- 5%, (n = 8). The leaves of Arbutus were then extracted successively with different solvents and the methanol extract was the most active. When tannins (primarily condensed tannins) were precipitated from the methanol extract, they showed a strong vasorelaxant activity (87% +/- 4%, n = 5), whereas the elimination of tannins in the methanol extract reduced significantly its vasorelaxant activity (42% +/- 8%, n = 8, p Arbutus is likely to be due to polyphenol compounds, primarily condensed tannins and catechin gallate. Copyright 2004 John Wiley & Sons, Ltd.

  3. Inhibitory effects of tiamulin on contractile and electrical responses in isolated thoracic aorta and cardiac muscle of guinea-pigs.

    Science.gov (United States)

    Nakajyo, S; Hara, Y; Hirano, S; Agata, N; Shimizu, K; Urakawa, N

    1992-09-01

    The inhibitory effect of tiamulin, an antibiotic produced by Pleurotus mutilis, on contractile and electrical responses in isolated thoracic aorta and cardiac muscle of guinea-pigs was studied. In the thoracic aorta, tiamulin with an IC50 of 9.7 x 10(-6) M inhibited sustained contractions induced by isosmotically added 60 mM KCl. The inhibitory effect of tiamulin on a Ca(2+)-induced contraction in a depolarized muscle was competitively antagonized by raising external Ca2+ concentration. Bay K 8644 (10(-7) M) antagonized tiamulin's inhibition of the Ca(2+)-induced contraction. Tiamulin (2 x 10(-5) M) decreased the elevated cytoplasmic Ca2+ level measured by the fura 2 AM method in the depolarized muscle. In high K(+)-isoprenaline-treated left atria, tiamulin (2 x 10(-5)-2 x 10(-4) M) produced negative inotropic effects. On the other hand in the membrane action potential of papillary muscles, tiamulin (2 x 10(-6)-2 x 10(-4) M) produced decreases in action potential and durations and 2 x 10(-4) M tiamulin depressed the slow response action potential in depolarized muscles. Tiamulin produced prolongations of the PR interval in ECG, negative chrono- and inotropic effects, and an increase in perfusion flow in guinea-pig isolated and perfused hearts. These effects of tiamulin on the aorta or cardiac muscle were similar to those of verapamil and nifedipine. These results suggest that both the inhibitory action of tiamulin on the high K(+)-induced contraction in the aorta and the negative inotropic effect of tiamulin on the cardiac muscle are due to an inhibition of Ca2+ entry through the voltage-dependent Ca2+ channels of cells of both these muscles.

  4. Ca2+ influx insensitive to organic Ca2+ entry blockers contributes to noradrenaline-induced contractions of the isolated guinea pig aorta

    NARCIS (Netherlands)

    Gouw, M. A.; Wilffert, B.; Wermelskirchen, D.; van Zwieten, P. A.

    1990-01-01

    We determined the contribution of intracellular Ca2+ to the noradrenaline (NA, 3 X 10(-5) mmol/l)-induced contraction of the isolated guinea pig aorta. Since only about 55% of the NA-induced contraction could be attributed to intracellular Ca2+ release, we assumed that a Ca2+ influx component

  5. Ca2+influx insensitive to organic Ca2+entry blockers contributes to noradrenaline-induced contractions of the isolated guinea pig aorta

    NARCIS (Netherlands)

    Gouw, M.A.M.; Wilffert, B.; Wermelskirchen, D.; Van Zwieten, P.A.

    1990-01-01

    We determined the contribution of intracellular Ca2+to the noradrenaline (NA, 3 x 10-5mmol/l)-induced contraction of the isolated guinea pig aorta. Since only about 55% of the NA-induced contraction could be attributed to intracellular Ca2+release, we assumed that a Ca2+influx component contributes

  6. Contribution of α-adrenoceptor stimulation by phenylephrine to basal nitric oxide production in the isolated mouse aorta.

    Science.gov (United States)

    van Langen, Johanna T H; Van Hove, Cor E; Schrijvers, Dorien M; Martinet, Wim; De Meyer, Guido R Y; Fransen, Paul; Bult, Hidde

    2013-04-01

    In the mouse aorta, contractions evoked by the α(1)-adrenoceptor agonist phenylephrine are strongly suppressed by the continuous production of nitric oxide (NO). We investigated whether phenylephrine itself stimulated NO production by activating endothelial α(2)-adrenoceptors. On a prostaglandin F(2α) contraction, the α(2)-adrenoceptor agonist 5-bromo-N-(4,5-dihydro-1H-imidazol-2-yl)-6-quinoxalinamine (UK14304) induced 29.3 ± 7.4% relaxation, which was inhibited by 0.1 μM 2-[(4,5-Dihydro-1H-imidazol-2-yl)methyl]-2,3-dihydro-1-methyl-1H-isoindole (BRL44408) with a pKB' corresponding to α(2)-antagonism. In the presence of NO synthase blockers, UK14304 elicited small contractions above 1 μM that were inhibited by 0.1 μM prazosin, but not influenced by 0.1 μM rauwolscine. At 3 μM or higher concentrations, phenylephrine caused only modest relaxation (up to 7.4 ± 2.3%) of segments constricted with prostaglandin F(2α) in the presence of prazosin, which was abolished with 0.1 μM BRL44408. Furthermore, BRL44408 did not increase contractions induced with 1 μM phenylephrine. These results confirm that α(1)- but not α(2)-adrenoceptors are expressed on aortic smooth muscle cells, whereas endothelial cells only express α(2)-adrenoceptors. Moreover, phenylephrine exerted a very modest relaxing effect through nonspecific stimulation of α(2)-adrenoceptors, but only at concentrations higher than 1 μM. It is concluded that the high basal output of NO in the isolated mouse aorta is not due to stimulation of α-adrenoceptors.

  7. Peroxynitrite-induced relaxation in isolated rat aortic rings and mechanisms of action

    International Nuclear Information System (INIS)

    Li Jianfeng; Li Wenyan; Altura, Bella T.; Altura, Burton M.

    2005-01-01

    The present study was designed to evaluate the effects of peroxynitrite (ONOO - ), the product of superoxide and nitric oxide, on isolated segments of rat aorta. In the absence of any vasoactive agent, ONOO - (from 10 -8 to 10 -4 M) failed to alter the basal tension. In phenylephrine (PE; 5 x 10 -7 M)-precontracted rat aortic rings (RAR), ONOO - elicited concentration-dependent relaxation at concentrations of from 10 -8 to 10 -4 M. The effective concentrations producing approximately 50% of maximal relaxation (ED 5 ) to ONOO - were 1.84 x 10 -5 M and 1.96 x 10 -5 M in intact and denuded RAR, respectively (P > 0.05). No significant differences in the relaxation responses were found between RAR with or without endothelium (P > 0.05). The presence of either 5 μM methylene blue (MB) or 5 μM 1H-[1,2,4]oxadiazolo-[4,3-α]quinoxalin-1-one (ODQ) significantly inhibited the relaxations induced by ONOO - . Sildenafil (10 -7 M), on the other hand, significantly potentiated the ONOO - -induced relaxations. Tetraethylammonium chloride (T-2265) significantly decreased the ONOO - -induced relaxations in a concentration-dependent manner. However, ONOO - had no effect on RAR precontracted by high KCL (40 mM, n = 6, P > 0.05). Addition of calyculin A also significantly decreased the ONOO - -induced relaxation in a dose-dependent manner. Furthermore, ONOO - significantly inhibited calcium-induced contractions of K + -depolarized aortic rings in a concentration-related manner. Lastly, a variety of other pharmacological agents and antagonists including L-NMMA, L-arginine, indomethacin, atropine, naloxone, diphenhydramine, cimetine, glibenclamide, haloperidol, superoxide dismutase (SOD), and catalase did not influence the relaxant effects of ONOO - on RAR. Our new results suggest that ONOO - -triggered relaxation on rat aortic rings is mediated by elevation of cGMP levels, membrane hyperpolarization via K + -channel activation, activation of myosin phosphatase activity, and

  8. Lipid Emulsion Inhibits Vasodilation Induced by a Toxic Dose of Bupivacaine via Attenuated Dephosphorylation of Myosin Phosphatase Target Subunit 1 in Isolated Rat Aorta

    Science.gov (United States)

    Ok, Seong-Ho; Byon, Hyo-Jin; Kwon, Seong-Chun; Park, Jungchul; Lee, Youngju; Hwang, Yeran; Baik, Jiseok; Choi, Mun-Jeoung; Sohn, Ju-Tae

    2015-01-01

    Lipid emulsions are widely used for the treatment of systemic toxicity that arises from local anesthetics. The goal of this in vitro study was to examine the cellular mechanism associated with the lipid emulsion-mediated attenuation of vasodilation induced by a toxic dose of bupivacaine in isolated endothelium-denuded rat aorta. The effects of lipid emulsion on vasodilation induced by bupivacaine, mepivacaine, and verapamil were assessed in isolated aorta precontracted with phenylephrine, the Rho kinase stimulant NaF, and the protein kinase C activator phorbol 12,13-dibutyrate (PDBu). The effects of Rho kinase inhibitor Y-27632 on contraction induced by phenylephrine or NaF were assessed. The effects of bupivacaine on intracellular calcium concentrations ([Ca2+]i) and tension induced by NaF were simultaneously measured. The effects of bupivacaine alone and lipid emulsion plus bupivacaine on myosin phosphatase target subunit 1 (MYPT1) phosphorylation induced by NaF were examined in rat aortic vascular smooth muscle cells. In precontracted aorta, the lipid emulsion attenuated bupivacaine-induced vasodilation but had no effect on mepivacaine-induced vasodilation. Y-27632 attenuated contraction induced by either phenylephrine or NaF. The lipid emulsion attenuated verapamil-induced vasodilation. Compared with phenylephrine-induced precontracted aorta, bupivacaine-induced vasodilation was slightly attenuated in NaF-induced precontracted aorta. The magnitude of the bupivacaine-induced vasodilation was higher than that of a bupivacaine-induced decrease in [Ca2+]i. Bupivacaine attenuated NaF-induced MYPT1 phosphorylation, whereas lipid emulsion pretreatment attenuated the bupivacaine-induced inhibition of MYPT1 phosphorylation induced by NaF. Taken together, these results suggest that lipid emulsions attenuate bupivacaine-induced vasodilation via the attenuation of inhibition of MYPT1 phosphorylation evoked by NaF. PMID:26664257

  9. EDRF [endothelium-derived relaxing factor]-release and Ca++-channel blockage by Magnolol, an antiplatelet agent isolated from Chinese herb Magnolia officinalis, in rat thoracic aorta

    International Nuclear Information System (INIS)

    Teng, Cheming; Yu, Sheumeei; Chen, Chienchih; Huang, Yulin; Huang, Turfu

    1990-01-01

    Magnolol is an antiplatelet agent isolated from Chinese herb Magnolia officinalis. It inhibited norepinephrine-induced phasic and tonic contractions in rat thoracic aorta. At the plateau of the NE-induced tonic contraction, addition of magnolol caused two phases (fast and slow) of relaxation. These two relaxations were concentration-dependent, and were not inhibited by indomethacin. The fast relaxation was completely antagonized by hemoglobin and methylene blue, and disappeared in de-endothelialized aorta while the slow relaxation was not affected by the above treatments. Magnolol also inhibited high potassium-induced, calcium-dependent contraction of rat aorta in a concentration-dependent manner. 45 Ca ++ influx induced by high potassium or NE was markedly inhibited by magnolol. Cyclic GMP, but not PGI 2 , was increased by magnolol in intact, but not in de-endothelialized aorta. It is concluded that magnolol relaxed vascular smooth muscle by releasing endothelium-derived relaxing factor (EDRF) and by inhibiting calcium influx through voltage-gated calcium channels

  10. Tributyltin contributes in reducing the vascular reactivity to phenylephrine in isolated aortic rings from female rats.

    Science.gov (United States)

    Rodrigues, Samya Mere L; Ximenes, Carolina F; de Batista, Priscila R; Simões, Fabiana V; Coser, Pedro Henrique P; Sena, Gabriela C; Podratz, Priscila L; de Souza, Leticia N G; Vassallo, Dalton V; Graceli, Jones B; Stefanon, Ivanita

    2014-03-21

    Organotin compounds such as tributyltin (TBT) are used as antifouling paints by shipping companies. TBT inhibits the aromatase responsible for the transformation of testosterone into estrogen. Our hypothesis is that TBT modulates the vascular reactivity of female rats. Female Wistar rats were treated daily (Control; CONT) or TBT (100 ng/kg) for 15 days. Rings from thoracic aortas were incubated with phenylephrine (PHE, 10(-10)-10(-4) M) in the presence and absence of endothelium, and in the presence of N(G)-Nitro-L-Arginine Methyl Ester (L-NAME), tetraethylammonium (TEA) and apocynin. TBT decreased plasma levels of estrogen and the vascular response to PHE. In the TBT group, the vascular reactivity was increased in the absence of endothelium, L-NAME and TEA. The decrease in PHE reactivity during incubation with apocynin was more evident in the TBT group. The sensitivity to acetylcholine (ACh) and sodium nitroprusside (SNP) was reduced in the TBT group. TBT increased collagen, reduced α1-smooth muscle actin. Female rats treated with TBT for 15 days showed morphology alteration of the aorta and decreased their vascular reactivity, probably due to mechanisms dependent on nitric oxide (NO) bioavailability, K(+) channels and an increase in oxidative stress. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Why Do Simple Molecules with "Isolated" Phenyl Rings Emit Visible Light?

    Science.gov (United States)

    Zhang, Haoke; Zheng, Xiaoyan; Xie, Ni; He, Zikai; Liu, Junkai; Leung, Nelson L C; Niu, Yingli; Huang, Xuhui; Wong, Kam Sing; Kwok, Ryan T K; Sung, Herman H Y; Williams, Ian D; Qin, Anjun; Lam, Jacky W Y; Tang, Ben Zhong

    2017-11-15

    π-Bonds connected with aromatic rings were generally believed as the standard structures for constructing highly efficient fluorophores. Materials without these typical structures, however, exhibited only low fluorescence quantum yields and emitted in the ultraviolet spectral region. In this work, three molecules, namely bis(2,4,5-trimethylphenyl)methane, 1,1,2,2-tetrakis(2,4,5-trimethylphenyl)ethane, and 1,1,2,2-tetraphenylethane, with nonconjugated structures and isolated phenyl rings were synthesized and their photophysical properties were systematically investigated. Interestingly, the emission spectra of these three molecules could be well extended to 600 nm with high solid-state quantum yields of up to 70%. Experimental and theoretical analyses proved that intramolecular through-space conjugation between the "isolated" phenyl rings played an important role for this abnormal phenomenon.

  12. Kinetic identification of an intracellular calcium compartment sensitive to phosphate and dinitrophenol in intact isolated rabbit aorta

    International Nuclear Information System (INIS)

    Hai, C.M.; Phair, R.D.

    1986-01-01

    Previous work from this laboratory revealed the presence of at least three distinct intracellular calcium compartments in intact segments of rabbit aorta. In this study one of these intracellular compartments is shown to be sensitive to dinitrophenol and to increased extracellular phosphate. Intact aortic segments were loaded with 45 Ca in bicarbonate-buffered physiologic salt solution for 1 hour, and then transferred to a flow-through chamber perfused with physiologic salt solution. Effluent from the chamber was collected for 8 hours, and 45 Ca efflux curves were analyzed using compartmental analysis. When aortic segments were loaded and washed out in dinitrophenol, the slowest component of the efflux curve was less prominent; in high phosphate it was more prominent. The rate constant changes required to account for these data were primarily in the exchange between the cytosolic and slowest intracellular calcium compartment, suggesting that the slowest calcium compartment resolved during the 8-hour washout was mitochondrial. This compartment contained 5.4 +/- 3.2 nmol calcium/g wet wt. tissue. The calcium flux across its membranes was 0.32 +/- 0.04 nmol min-1g-1. Because this flux is much smaller than the plasma-membrane calcium flux, we suggest that, in normal physiological circumstances, plasma-membrane extrusion is more important for the removal of Ca from the smooth muscle cytosol than is uptake into this slow intracellular compartment

  13. High Isolation Dual-Polarized Patch Antenna with Hybrid Ring Feeding

    Directory of Open Access Journals (Sweden)

    Xian-Jing Lin

    2017-01-01

    Full Text Available This paper presents a hybrid ring feeding dual-polarized patch antenna with high isolation in a wide working band. The proposed antenna consists of a circular radiating patch printed on the upper horizontal substrate, two pairs of Γ shaped strips printed on two vertical substrates, and a hybrid ring feeding network printed on the lower two horizontal substrates. The proposed antenna adopts Γ shape strips coupled feeding structure to achieve a wide operating band. Furthermore, a hybrid ring feeding structure with high isolation in a wide bandwidth, which is firstly proposed, is applied as feeding network. When one port is excited, the feeding network can realize twice the power cancellation. Thus, high ports isolation characteristics can be obtained. A prototype of the proposed antenna is fabricated and measured. Measured results show that the 10 dB reflection coefficient bandwidths of the two ports are both about 38.7%, with port isolation higher than 40 dB through most of the band, and the cross-polarizations are below −24 dB.

  14. Restriction analysis of genetic variability of Polish isolates of Tomato black ring virus.

    Science.gov (United States)

    Jończyk, Magdalena; Borodynko, Natasza; Pospieszny, Henryk

    2004-01-01

    Several different isolates of Tomato black ring virus (TBRV) have been collected in Poland from cucumber, tomato, potato and black locust plants. Biological tests showed some differences in the range of infected plants and the type of symptoms, which was the basis for selection of seven the most biologically different TBRV isolates. According to the sequence of TBRV-MJ, several primer pairs were designed and almost the entire sequence of both genomic RNAs was amplified. The RT-PCR products derived from all tested TBRV isolates were digested by restriction enzymes. On the basis of the restriction patterns, the variable and the conserved regions of the TBRV genome were defined and the relationships between the Polish TBRV isolates established.

  15. Polydatin Restores Endothelium-Dependent Relaxation in Rat Aorta Rings Impaired by High Glucose: A Novel Insight into the PPARβ-NO Signaling Pathway.

    Directory of Open Access Journals (Sweden)

    Yang Wu

    Full Text Available Polydatin, a natural component from Polygonum Cuspidatum, has important therapeutic effects on metabolic syndrome. A novel therapeutic strategy using polydatin to improve vascular function has recently been proposed to treat diabetes-related cardiovascular complications. However, the biological role and molecular basis of polydatin's action on vascular endothelial cells (VECs-mediated vasodilatation under diabetes-related hyperglycemia condition remain elusive. The present study aimed to assess the contribution of polydatin in restoring endothelium-dependent relaxation and to determine the details of its underlying mechanism. By measuring endothelium-dependent relaxation, we found that acetylcholine-induced vasodilation was impaired by elevated glucose (55 mmol/L; however, polydatin (1, 3, 10 μmol/L could restore the relaxation in a dose-dependent manner. Polydatin could also improve the histological damage to endothelial cells in the thoracic aorta. Polydatin's effects were mediated via promoting the expression of endothelial NO synthase (eNOS, enhancing eNOS activity and decreasing the inducible NOS (iNOS level, finally resulting in a beneficial increase in NO release, which probably, at least in part, through activation of the PPARβ signaling pathway. The results provided a novel insight into polydatin action, via PPARβ-NO signaling pathways, in restoring endothelial function in high glucose conditions. The results also indicated the potential utility of polydatin to treat diabetes related cardiovascular diseases.

  16. Hemodynamic and Mechanical Properties of the Proximal Aorta in Young and Middle-Aged Adults With Isolated Systolic Hypertension: The Dallas Heart Study.

    Science.gov (United States)

    Yano, Yuichiro; Neeland, Ian J; Ayers, Colby; Peshock, Ronald; Berry, Jarett D; Lloyd-Jones, Donald M; Greenland, Philip; Mitchell, Gary F; Vongpatanasin, Wanpen

    2017-07-01

    The aim of this study was to assess characteristic impedance (Z c ) of the proximal aorta in young and middle-aged individuals with isolated systolic hypertension (ISH). Z c is an index of aortic stiffness relative to aortic size. In the Dallas Heart Study, 2001 untreated participants 18 to 64 years of age (mean age: 42.3 years; 44% black race) were divided into the following groups based on office blood pressure (BP) measurements: (1) optimal BP (systolic BP [SBP] hypertension (SBP hypertension (SBP ≥140 mm Hg and DBP ≥90 mm Hg; n=178). Z c , aortic arch pulse wave velocity, and minimum ascending aortic size were quantified using cardiovascular magnetic resonance. In multivariable-adjusted linear models, Z c was highest in the ISH group compared with the optimal BP, isolated diastolic hypertension, or systolic-diastolic hypertension groups (103.2±4.0 versus 68.3±2.1, 75.4±6.0, and 88.9±4.8 dyne*seconds/cm 5 , respectively; all P hypertension, or systolic-diastolic hypertension groups (6.3±0.3 versus 4.3±0.1, 4.4±0.4 and 5.5±0.3 m/s, respectively; all P 0.2). Results were similar in a subgroup of 1551 participants 18 to 49 years of age. In a multiracial population-based sample, we found evidence of a mismatch between proximal aortic stiffness and diameter in young and middle-aged adults with ISH. © 2017 American Heart Association, Inc.

  17. A combined dynamic analysis method for geometrically nonlinear vibration isolators with elastic rings

    Science.gov (United States)

    Hu, Zhan; Zheng, Gangtie

    2016-08-01

    A combined analysis method is developed in the present paper for studying the dynamic properties of a type of geometrically nonlinear vibration isolator, which is composed of push-pull configuration rings. This method combines the geometrically nonlinear theory of curved beams and the Harmonic Balance Method to overcome the difficulty in calculating the vibration and vibration transmissibility under large deformations of the ring structure. Using the proposed method, nonlinear dynamic behaviors of this isolator, such as the lock situation due to the coulomb damping and the usual jump resulting from the nonlinear stiffness, can be investigated. Numerical solutions based on the primary harmonic balance are first verified by direct integration results. Then, the whole procedure of this combined analysis method is demonstrated and validated by slowly sinusoidal sweeping experiments with different amplitudes of the base excitation. Both numerical and experimental results indicate that this type of isolator behaves as a hardening spring with increasing amplitude of the base excitation, which makes it suitable for isolating both steady-state vibrations and transient shocks.

  18. Molecular characterisation of an avihepadnavirus isolated from Psittacula krameri (ring-necked parrot).

    Science.gov (United States)

    Piasecki, Tomasz; Kurenbach, Brigitta; Chrząstek, Klaudia; Bednarek, Karolina; Kraberger, Simona; Martin, Darren P; Varsani, Arvind

    2012-03-01

    Avihepadnaviruses have been documented previously in ducks, herons, geese, storks and cranes. Here, we describe the full genome of a new avihepadnavirus isolated from Psittacula krameri (ring-necked parrot) in Poland. The parrot hepatitis B virus (PHBV) genome (3042 bp) shares <76% sequence identity with other avihepadnavirus isolates and is phylogenetically most closely related to heron and stork hepatitis B viruses isolates. PHBV has a genome organization similar to that of other hepadnaviruses and contains ORFs for a preC/C, preS/S and polyprotein. Additionally, we identified an X-like ORF in the genome of PHBV. The full-genome data will be useful in developing screening tools for avihepadnaviruses in parrots.

  19. LNA probe-based assay for the detection of Tomato black ring virus isolates.

    Science.gov (United States)

    Hasiów-Jaroszewska, Beata; Rymelska, Natalia; Borodynko, Natasza

    2015-02-01

    Tomato black ring virus (TBRV) infects a wide range of economically important plant species worldwide. In the present study we developed a locked nucleic acid (LNA) real-time RT-PCR assay for accurate detection of genetically diverse TBRV isolates collected from different hosts. The assay based on the LNA probe has a wide detection range, high sensitivity, stability and amplification efficiency. The assay amplified all tested TBRV isolates, but no signal was observed for the RNA from other nepoviruses and healthy plant species. Under optimum reaction conditions, the detection limit was estimated around 17 copies of the TBRV target region in total RNA. Real-time RT-PCR with the LNA probe described in this paper will serve as a valuable tool for robust, sensitive and reliable detection of TBRV isolates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Protein kinase A and C regulate leak potassium currents in freshly isolated vascular myocytes from the aorta.

    Directory of Open Access Journals (Sweden)

    Sébastien Hayoz

    Full Text Available We tested the hypothesis that protein kinase A (PKA inhibits K2P currents activated by protein kinase C (PKC in freshly isolated aortic myocytes. PDBu, the PKC agonist, applied extracellularly, increased the amplitude of the K2P currents in the presence of the "cocktail" of K(+ channel blockers. Gö 6976 significantly reduced the increase of the K2P currents by PDBu suggesting the involvement of either α or β isoenzymes of PKC. We found that forskolin, or membrane permeable cAMP, did not inhibit K2P currents activated by the PKC. However, when PKA agonists were added prior to PDBu, they produced a strong decrease in the K2P current amplitudes activated by PKC. Inhibition of PDBu-elicited K2P currents by cAMP agonists was not prevented by the treatment of vascular smooth muscle cells with PKA antagonists (H-89 and Rp-cAMPs. Zn(2+ and Hg(2+ inhibited K2P currents in one population of cells, produced biphasic responses in another population, and increased the amplitude of the PDBu-elicited K(+ currents in a third population of myocytes, suggesting expression of several K2P channel types. We found that cAMP agonists inhibited biphasic responses and increase of amplitude of the PDBu-elicited K2P currents produced by Zn(2+ and Hg(2. 6-Bnz-cAMp produced a significantly altered pH sensitivity of PDBu-elicited K2P-currents, suggesting the inhibition of alkaline-activated K2P-currents. These results indicate that 6-Bnz-cAMP and other cAMP analogs may inhibit K2P currents through a PKA-independent mechanism. cAMP analogs may interact with unidentified proteins involved in K2P channel regulation. This novel cellular mechanism could provide insights into the interplay between PKC and PKA pathways that regulate vascular tone.

  1. Trichomonas vaginalis clinical isolates: cytoadherence and adherence to polystyrene, intrauterine device, and vaginal ring.

    Science.gov (United States)

    Dos Santos, Odelta; Rigo, Graziela Vargas; Macedo, Alexandre José; Tasca, Tiana

    2017-12-01

    The parasitism by Trichomonas vaginalis is complex and in part is mediated by cytoadherence accomplished via five surface proteins named adhesins and a glycoconjugate called lipophosphoglycan (TvLPG). In this study, we evaluated the ability of T. vaginalis isolates to adhere to cells, plastic (polystyrene microplates), intrauterine device (IUD), and vaginal ring. Of 32 T. vaginalis isolates, 4 (12.5%) were strong adherent. The T. vaginalis isolates TV-LACM6 and TV-LACM14 (strong polystyrene-adherent) were also able to adhere to IUD and vaginal ring. Following chemical treatments, results demonstrated that the T. vaginalis components, lipophosphoglycan, cytoskeletal proteins, and surface molecules, were involved in both adherence to polystyrene and cytoadherence. The gene expression level from four adhesion proteins was highest in trophozoites adhered to cells than trophozoites adhered to the abiotic surface (polystyrene microplate). Our data indicate the major involvement of TvLPG in adherence to polystyrene, and that adhesins are important for cytoadherence. Furthermore, to our knowledge, this is the first report showing the T. vaginalis adherence to contraceptive devices, reaffirming its importance as pathogen among women in reproductive age.

  2. Photochemical Ring-Opening Reaction in 2(1H)-Pyrimidinones: A Matrix Isolation Study

    OpenAIRE

    Lapinski, Leszek; Rostkowska, Hanna; Khvorostov, Artem; Fausto, Rui; Nowak, Maciej J.

    2003-01-01

    Photoreactions induced by UV-B (290−320 nm) irradiation were studied for 1-methyl-2(1H)-pyrimidinone and 1-methylcytosine monomers isolated in low-temperature inert gas matrixes. A Norrish type I α-cleavage reaction leading to open-ring conjugated isocyanate was observed for 1-methyl-2(1H)-pyrimidinone. The structure of the photoproduct was identified by comparison of its experimental IR spectrum with the spectrum theoretically calculated at the DFT(B3LYP)/6-31++G(d,p) level. The main indicat...

  3. Predictors for reproductive isolation in a ring species complex following genetic and ecological divergence.

    Science.gov (United States)

    Pereira, Ricardo J; Monahan, William B; Wake, David B

    2011-07-06

    Reproductive isolation (RI) is widely accepted as an important "check point" in the diversification process, since it defines irreversible evolutionary trajectories. Much less consensus exists about the processes that might drive RI. Here, we employ a formal quantitative analysis of genetic interactions at several stages of divergence within the ring species complex Ensatina eschscholtzii in order to assess the relative contribution of genetic and ecological divergence for the development of RI. By augmenting previous genetic datasets and adding new ecological data, we quantify levels of genetic and ecological divergence between populations and test how they correlate with a restriction of genetic admixture upon secondary contact. Our results indicate that the isolated effect of ecological divergence between parental populations does not result in reproductively isolated taxa, even when genetic transitions between parental taxa are narrow. Instead, processes associated with overall genetic divergence are the best predictors of reproductive isolation, and when parental taxa diverge in nuclear markers we observe a complete cessation of hybridization, even to sympatric occurrence of distinct evolutionary lineages. Although every parental population has diverged in mitochondrial DNA, its degree of divergence does not predict the extent of RI. These results show that in Ensatina, the evolutionary outcomes of ecological divergence differ from those of genetic divergence. While evident properties of taxa may emerge via ecological divergence, such as adaptation to local environment, RI is likely to be a byproduct of processes that contribute to overall genetic divergence, such as time in geographic isolation, rather than being a direct outcome of local adaptation.

  4. Analysis of the biological and molecular variability of the Polish isolates of Tomato black ring virus (TBRV).

    Science.gov (United States)

    Rymelska, N; Borodynko, N; Pospieszny, H; Hasiów-Jaroszewska, B

    2013-10-01

    Tomato black ring virus (TBRV) is an important pathogen infecting many plant species worldwide. The biological and molecular variability of the Polish isolates of TBRV was analyzed. The analysis was performed based on the symptoms induced by various isolates on test plant species as well as on phylogenetic relationships between isolates. Isolates differed in their host range and symptomatology. In addition, genetic variation among isolates was characterized by restriction fragment length polymorphism analysis and confirmed by sequencing. The phylogenetic analysis revealed that the Polish isolates differ from each other and do not form a monophyletic cluster. Finally, we identified and analyzed sequences of defective RNA forms arising from the TBRV genome.

  5. The use of 3D contrast-enhanced CT reconstructions to project images of vascular rings and coarctation of the aorta.

    Science.gov (United States)

    Di Sessa, Thomas G; Di Sessa, Peter; Gregory, Bill; Vranicar, Mark

    2009-01-01

    Aortic arch and pulmonary artery anomalies make up a group of vascular structures that have complex three-dimensional (3D) shapes. Tortuosity as well as hypoplasia or atresia of segments of the aortic arch or pulmonary artery makes the conventional two-dimensional (2D) imaging difficult. Nine patients with native coarctation or recoarctation and 4 patients with a vascular ring had a CT scan as a part of their clinical evaluation. There were 7 males. The mean age was 11.7 years. (range 19 days to 29 years) The mean weight was 22.7 kg (range 3.3-139.0 kg). The dicom data from contrast CT scans were converted by the Amira software package into a 3D image. The areas of interest were selected. The images were then projected in 3D on a standard video monitor and could be rotated 360 degrees in any dimension. Adequate CT scans and 3D reconstructions were obtained in 12 of 13 patients. There were 85-1,044 slices obtained in the adequate studies. We could not reconstruct a 3D image from a patient's CT scan that had only 22 slices. The anatomy defined by 3D was compared to 2D CT imaging and confirmed by cardiac catheterization or direct visualization in the operating room in the 12 patients with adequate 3D reconstructions. In 5 of 12 patients, 3D reconstructions provided valuable spatial information not observed in the conventional 2D scans. We believe that 3D reconstruction of contrast-enhanced CT scans of these complex structures provides additional valuable information that is helpful in the decision-making process.

  6. Relaxant effects of a hydroalcoholic extract of Ruta graveolens on isolated rat tracheal rings

    Directory of Open Access Journals (Sweden)

    Luis Águila

    2015-01-01

    Full Text Available BACKGROUND: Ruta graveolens L. (R. graveolens is a medicinal plant employed in non-traditional medicines that has various therapeutic properties, including anthelmintic, and vasodilatory actions, among others. We evaluated the trachea-relaxant effects of hydroalcoholic extract of R. graveolens against potassium chloride (KCl- and carbachol-induced contraction of rat tracheal rings in an isolated organ bath. RESULTS: The results showed that the airway smooth muscle contraction induced by the depolarizing agent (KCl and cholinergic agonist (carbachol was markedly reduced by R. graveolens in a concentration-dependent manner, with maximum values of 109 ± 7.9 % and 118 ± 2.6 %, respectively (changes in tension expressed as positive percentages of change in proportion to maximum contraction, at the concentration of 45 μg/mL (half-maximal inhibitory concentration IC50: 35.5 μg/mL and 27.8 μg/mL for KCl- and carbachol-induced contraction, respectively. Additionally, the presence of R. graveolens produced rightward parallel displacement of carbachol dose-response curves and reduced over 35 % of the maximum smooth muscle contraction. CONCLUSIONS: The hydroalcoholic extract of R. graveolens exhibited relaxant activity on rat tracheal rings. The results suggest that the trachea-relaxant effect is mediated by a non-competitive antagonistic mechanism. More detailed studies are needed to identify the target of the inhibition, and to determine more precisely the pharmacological mechanisms involved in the observed biological effects.

  7. Vasodilator Activity of the Essential Oil from Aerial Parts of Pectis brevipedunculata and Its Main Constituent Citral in Rat Aorta

    Directory of Open Access Journals (Sweden)

    Gisele Zapata-Sudo

    2013-03-01

    Full Text Available The essential oil of Pectis brevipedunculata (EOPB, a Brazilian ornamental aromatic grass, is characterized by its high content of citral (81.9%: neral 32.7% and geranial 49.2%, limonene (4.7% and α-pinene (3.4%. Vasodilation induced by EOPB and isolated citral was investigated in pre-contracted vascular smooth muscle, using thoracic aorta from Wistar Kyoto (WKY rats which was prepared for isometric tension recording. EOPB promoted intense relaxation of endothelium-intact and denuded aortic rings with the concentration to induce 50% of the maximal relaxation (IC50 of 0.044% ± 0.006% and 0.093% ± 0.015% (p 0.05. In endothelium-intact aorta, EOPB-induced vasorelaxation was significantly reduced by L-NAME, a nitric oxide synthase inhibitor. The vasodilator activity of citral was increased in the KCl-contracted aorta and citral attenuated the contracture elicited by Ca2+ in depolarized aorta. EOPB and citral elicited vasorelaxation on thoracic aorta by affecting the NO/cyclic GMP pathway and the calcium influx through voltage-dependent L-type Ca2+ channels, respectively.

  8. Vasodilator activity of the essential oil from aerial parts of Pectis brevipedunculata and its main constituent citral in rat aorta.

    Science.gov (United States)

    Pereira, Sharlene Lopes; Marques, André Mesquita; Sudo, Roberto Takashi; Kaplan, Maria Auxiliadora Coelho; Zapata-Sudo, Gisele

    2013-03-07

    The essential oil of Pectis brevipedunculata (EOPB), a Brazilian ornamental aromatic grass, is characterized by its high content of citral (81.9%: neral 32.7% and geranial 49.2%), limonene (4.7%) and α-pinene (3.4%). Vasodilation induced by EOPB and isolated citral was investigated in pre-contracted vascular smooth muscle, using thoracic aorta from Wistar Kyoto (WKY) rats which was prepared for isometric tension recording. EOPB promoted intense relaxation of endothelium-intact and denuded aortic rings with the concentration to induce 50% of the maximal relaxation (IC50) of 0.044% ± 0.006% and 0.093% ± 0.015% (p 0.05). In endothelium-intact aorta, EOPB-induced vasorelaxation was significantly reduced by L-NAME, a nitric oxide synthase inhibitor. The vasodilator activity of citral was increased in the KCl-contracted aorta and citral attenuated the contracture elicited by Ca2+ in depolarized aorta. EOPB and citral elicited vasorelaxation on thoracic aorta by affecting the NO/cyclic GMP pathway and the calcium influx through voltage-dependent L-type Ca2+ channels, respectively.

  9. Coarctation of the Aorta

    Science.gov (United States)

    ... the wall of the left ventricle to thicken (hypertrophy). Risk factors Coarctation of the aorta often occurs ... body. Over time, this can cause your heart muscle to thicken and lead to symptoms such as ...

  10. Coarctation of the aorta

    Science.gov (United States)

    ... the legs is usually weaker than in the arms. Blood pressure is usually higher in the arms after infancy. ... be used to see if there are any differences in blood pressure in different areas of the aorta. Treatment Most ...

  11. Ropivacaine-Induced Contraction Is Attenuated by Both Endothelial Nitric Oxide and Voltage-Dependent Potassium Channels in Isolated Rat Aortae

    Directory of Open Access Journals (Sweden)

    Seong-Ho Ok

    2013-01-01

    Full Text Available This study investigated endothelium-derived vasodilators and potassium channels involved in the modulation of ropivacaine-induced contraction. In endothelium-intact rat aortae, ropivacaine concentration-response curves were generated in the presence or absence of the following inhibitors: the nonspecific nitric oxide synthase (NOS inhibitor Nω-nitro-L-arginine methyl ester (L-NAME, the neuronal NOS inhibitor Nω-propyl-L-arginine hydrochloride, the inducible NOS inhibitor 1400W dihydrochloride, the nitric oxide-sensitive guanylyl cyclase (GC inhibitor ODQ, the NOS and GC inhibitor methylene blue, the phosphoinositide-3 kinase inhibitor wortmannin, the cytochrome p450 epoxygenase inhibitor fluconazole, the voltage-dependent potassium channel inhibitor 4-aminopyridine (4-AP, the calcium-activated potassium channel inhibitor tetraethylammonium (TEA, the inward-rectifying potassium channel inhibitor barium chloride, and the ATP-sensitive potassium channel inhibitor glibenclamide. The effect of ropivacaine on endothelial nitric oxide synthase (eNOS phosphorylation in human umbilical vein endothelial cells was examined by western blotting. Ropivacaine-induced contraction was weaker in endothelium-intact aortae than in endothelium-denuded aortae. L-NAME, ODQ, and methylene blue enhanced ropivacaine-induced contraction, whereas wortmannin, Nω-propyl-L-arginine hydrochloride, 1400W dihydrochloride, and fluconazole had no effect. 4-AP and TEA enhanced ropivacaine-induced contraction; however, barium chloride and glibenclamide had no effect. eNOS phosphorylation was induced by ropivacaine. These results suggest that ropivacaine-induced contraction is attenuated primarily by both endothelial nitric oxide and voltage-dependent potassium channels.

  12. Methodologic aspects of acetylcholine-evoked relaxation of rabbit aorta

    DEFF Research Database (Denmark)

    Larsen, Kirsten Vendelbo; Nedergaard, Ove A.

    1999-01-01

    The acetylcholine-evoked relaxation of rabbit isolated thoracic aorta precontracted by phenylephrine was studied. Phenylephrine caused a steady contraction that was maintained for 6 h. In the presence of calcium disodium ethylenediaminetetraacetate (EDTA) and ascorbic acid the contraction decreased...

  13. Coarctation of the aorta

    International Nuclear Information System (INIS)

    Gogova, T.; Janev, I.

    2015-01-01

    Full text: Coarctation of the aorta is a congenital malformation representing a zone of strong narrowing of the aortic lumen, leading to impaired blood flow. In 90% of cases it affects isthmus vessel - the part between the separation of the left Ater subclavian and ductus arteriosus and it is often combined with other congenital heart defects and occurs more frequently in males. A case of juvenile isthmus type coarctation of the aorta at a young woman suffering from long hard to control hypertension, with intermittent discomfort in precordium and heart murmur is presented. Upon receipt of the patient a conventional radiography of organs in the chest front projection, which establishes a typical disease finding is carried out. After that a noninvasive computer-tomography angiography of the thoracic aorta, with CT Siemens Definition AS with a slice thickness 5 mm, subsequent reconstruction of 0,75 mm and postreconstruction were conducted. CT angiography study demonstrates the pathological constriction, the state of the aorta before and after constriction as well as the rich collateral vasculature of the intercostal and internal thoracic arteries. The available 3D reconstructions and postprocessing have been supported the establishment of optimal preoperative plan. The patient was subjected to surgery with vessel recovery and at the moment the patient is with excellent postoperative results

  14. Rapid detection of genetically diverse tomato black ring virus isolates using reverse transcription loop-mediated isothermal amplification.

    Science.gov (United States)

    Hasiów-Jaroszewska, Beata; Budzyńska, Daria; Borodynko, Natasza; Pospieszny, Henryk

    2015-12-01

    A reverse transcription loop-mediated isothermal amplification assay (RT-LAMP) has been developed for detection of tomato black ring virus (TBRV) isolates collected from different hosts. One-step RT-LAMP was performed with a set of four primers, the design of which was based on the coat protein gene. Results of RT-LAMP were visualized by direct staining of products with fluorescent dyes, agarose gel electrophoresis, and analysis of amplification curves. The sensitivity of RT-LAMP was 100-fold greater than that of RT-PCR. The RT-LAMP assay developed here is a useful and practical method for diagnosis of TBRV.

  15. New graft sizing rings for aortic valve reimplantation procedures.

    Science.gov (United States)

    Jelenc, Matija; Jelenc, Blaž; Kneževic, Ivan; Klokocovnik, Tomislav

    2018-01-01

    The objective was to design sizing rings that would enable proper sizing of the graft in reimplantation procedures and to perform leaflet repair before graft implantation. The rings were designed in Autodesk Fusion 360 (San Rafael, CA, USA) and 3D printed using a commercial online 3D printing service. We designed incomplete rings with a low profile and complete rings with a high profile. The complete rings are best suited for reimplantation procedures, whereas low profile C rings are intended for isolated aortic valve repair, where the ascending aorta is not transected. The rings come in sizes corresponding to Vascutek Gelweave graft sizes (Vascutek Terumo, Renfrewshire, Scotland). The ring internal diameters are 5% larger than the designated ring sizes and account for the 5% stretch of the grafts when pressurized. Blades of the rings are placed at 20° intervals. The slits between the blades are designed in such a way that the commissural U-sutures, when put in place and under tension, will lock the ring in position. The rings were successfully used in 10 of our latest reimplantation procedures. After dissection of the aortic root, the commissures were suspended with U-stitches and then the ring was seated onto them. Complete leaflet repair with plication to achieve adequate effective height was then performed, followed by graft implantation. No additional leaflet repair was needed. The newly designed sizing rings enable proper sizing of the graft in reimplantation procedures and enable complete leaflet repair before graft implantation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Role of endothelium in enhancement ofα1-adrenoceptor-mediated vasoconstriction by bupivacaine in isolated rat aorta%布比卡因增强α1受体介导大鼠胸主动脉收缩反应中血管内皮的作用

    Institute of Scientific and Technical Information of China (English)

    张贺飞; 许文琪; 都倩; 赵静; 夏红月; 任雷鸣

    2016-01-01

    Aim To investigate the role of endothe-lium in the enhancement of phenylephrine-mediated vasoconstriction by bupivacaine in the isolated rat aor-ta.Methods The isolated rat aortic rings were pre-pared, and the vascular endothelium was removed chemically or physically .Phenylephrine-mediated vas-oconstriction was recorded .Results A pretreatment with bupivacaine at 30 μmol · L-1 for 20 min signifi-cantly increased the Emax value of vasoconstrictive re-sponses to phenylephrine from 2.22 ±0.07 g of sol-vent-controlled group to 2.50 ±0.05 g ( P0.05 ) .A pretreatment with bupivacaine at 30 μmol · L-1 for 20 min slightly but significantly inhibited the vasoconstrictive responses to low concen-tration of phenylephrine in the isolated endothelium-de-nuded rat aorta (P0.05 ) .Conclusion Bupivacaine enhances α1-adre-noceptor-mediated vasoconstriction by inhibiting vascu-lar endothelium in the isolated endothelium-intact rat aorta, Which potentiates indirectly the vasoconstrictive responses to phenylephrine .%目的:分析血管内皮在布比卡因( bupivacaine , BUP )增强苯肾上腺素(phenylephrine,Phe)诱发血管收缩反应中的作用。方法制备大鼠离体胸主动脉血管环,采用机械损伤或工具药干扰血管内皮的舒张功能。记录Phe作为α1受体激动剂诱发的动脉收缩反应。结果 BUP (30μmol · L-1)与内皮完整血管标本孵育20 min后,Phe诱发的血管收缩Emax值为(2.50±0.05) g,明显高于对照组标本的Emax值[(2.22±0.07) g,P<0.01]。孵育时间缩短至5、10或15 min时,BUP无此增强效应。在内皮损伤动脉标本,同浓度BUP孵育20 min时,轻度但明显抑制低浓度Phe诱发的血管收缩反应( P<0.05)。在吲哚美辛、ChTX、apamin 和 L-NAME预处理的内皮完整血管标本上,ACh诱发的血管舒张反应消失;此时BUP(30μmol· L-1孵育20 min)对Phe诱发的血管收缩反应无明显影响( P>0.05)。结论

  17. A novel stress isolation guard-ring design for the improvement of a three-axis piezoresistive accelerometer

    International Nuclear Information System (INIS)

    Hsieh, Hsieh-Shen; Chang, Heng-Chung; Hu, Chih-Fan; Cheng, Chao-Lin; Fang, Weileun

    2011-01-01

    This study designs and implements a stress isolation guard-ring structure to improve the performances of the existing single proof-mass three-axis piezoresistive accelerometer. Thus, the environment disturbances, such as temperature variation and force/deflection transmittance, for a packaged three-axis piezoresistive accelerometer are significantly reduced. In application, the three-axis piezoresistive accelerometer has been fabricated using the bulk micromachining process on the SOI wafer. Experimental results show that the out-of-plane deformation of the suspended spring mass on the packaged accelerometer is reduced from 0.72 to 0.10 µm at a 150 °C temperature elevation. The temperature coefficient of zero-g offset for the presented sensor is reduced, and the temperature-induced sensitivity variation is minimized as well. Measurements also demonstrate that the guard-ring design successfully reduces the false signals induced by the force and displacement transmittance disturbances for one order of magnitude. Moreover, the three-axis acceleration sensing for the presented accelerometer with guard ring has also been demonstrated with sensitivities of 0.12–0.17 mV V −1 g −1 and nonlinearity < 1.02%.

  18. Turner Syndrome in Girls Presenting with Coarctation of the Aorta.

    Science.gov (United States)

    Eckhauser, Aaron; South, Sarah T; Meyers, Lindsay; Bleyl, Steven B; Botto, Lorenzo D

    2015-11-01

    To evaluate the frequency of Turner syndrome in a population-based, statewide cohort of girls with coarctation of the aorta. The Utah Birth Defects Network was used to ascertain a cohort of girls between 1997 and 2011 with coarctation of the aorta. Livebirths with isolated coarctation of the aorta or transverse arch hypoplasia were included and patients with complex congenital heart disease not usually seen in Turner syndrome were excluded. Of 244 girls with coarctation of the aorta, 77 patients were excluded, leaving a cohort of 167 girls; 86 patients (51%) had chromosomal studies and 21 (12.6%) were diagnosed with Turner syndrome. All patients were diagnosed within the first 4 months of life and 5 (24%) were diagnosed prenatally. Fifteen patients (71%) had Turner syndrome-related findings in addition to coarctation of the aorta. Girls with mosaicism were less likely to have Turner syndrome-associated findings (3/6 mosaic girls compared with 12/17 girls with non-mosaic 45,X). Twelve girls (57%) diagnosed with Turner syndrome also had a bicommissural aortic valve. At least 12.6% of girls born with coarctation of the aorta have karyotype-confirmed Turner syndrome. Such a high frequency, combined with the clinical benefits of an early diagnosis, supports genetic screening for Turner syndrome in girls presenting with coarctation of the aorta. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Isolation of Chromatin from Dysfunctional Telomeres Reveals an Important Role for Ring1b in NHEJ-Mediated Chromosome Fusions

    Directory of Open Access Journals (Sweden)

    Cristina Bartocci

    2014-05-01

    Full Text Available When telomeres become critically short, DNA damage response factors are recruited at chromosome ends, initiating a cellular response to DNA damage. We performed proteomic isolation of chromatin fragments (PICh in order to define changes in chromatin composition that occur upon onset of acute telomere dysfunction triggered by depletion of the telomere-associated factor TRF2. This unbiased purification of telomere-associated proteins in functional or dysfunctional conditions revealed the dynamic changes in chromatin composition that take place at telomeres upon DNA damage induction. On the basis of our results, we describe a critical role for the polycomb group protein Ring1b in nonhomologous end-joining (NHEJ-mediated end-to-end chromosome fusions. We show that cells with reduced levels of Ring1b have a reduced ability to repair uncapped telomeric chromatin. Our data represent an unbiased isolation of chromatin undergoing DNA damage and are a valuable resource to map the changes in chromatin composition in response to DNA damage activation.

  20. Integrated Microwave Photonic Isolators: Theory, Experimental Realization and Application in a Unidirectional Ring Mode-Locked Laser Diode

    Directory of Open Access Journals (Sweden)

    Martijn J.R. Heck

    2015-09-01

    Full Text Available A novel integrated microwave photonic isolator is presented. It is based on the timed drive of a pair of optical modulators, which transmit a pulsed or oscillating optical signal with low loss, when driven in phase. A signal in the reverse propagation direction will find the modulators out of phase and, hence, will experience high loss. Optical and microwave isolation ratios were simulated to be in the range up to 10 dB and 20 dB, respectively, using parameters representative for the indium phosphide platform. The experimental realization of this device in the hybrid silicon platform showed microwave isolation in the 9 dB–22 dB range. Furthermore, we present a design study on the use of these isolators inside a ring mode-locked laser cavity. Simulations show that unidirectional operation can be achieved, with a 30–50-dB suppression of the counter propagating mode, at limited driving voltages. The potentially low noise and feedback-insensitive operation of such a laser makes it a very promising candidate for use as on-chip microwave or comb generators.

  1. Design of S-Band Phased Array Antenna with High Isolation Using Broadside Coupled Split Ring Resonator

    Directory of Open Access Journals (Sweden)

    Sungyoun Hwang

    2018-04-01

    Full Text Available In this paper, a method of designing a Vivaldi type phased array antenna (PAA which operates at S-band (2.8–3.3 GHz is presented. The presented antenna uses broadside coupled split ring resonators (BC-SRRs for high isolation, wide field of view, and good active S-parameter characteristics. As an example, we design a 1 × 8 array antenna with various BC-SRR structures using theory and EM simulations. The antenna is fabricated and measured to verify the design. With the BC-SRR implemented between the two radiating elements, the isolation is shown to be enhanced by 6 dB, up to 23 dB. The scan angle is shown to be within ±53° based on a −10 dB active reflection coefficient. The operation of the scan angle is possible within ±60° with a little larger reflection coefficient (−7 dB to −8 dB. The proposed design with BC-SRRs is expected to be useful for PAA applications.

  2. Cilostazol enhances atorvastatin-induced vasodilation of female rat aorta during aging.

    Science.gov (United States)

    Nurullahoğlu-Atalık, K E; Kutlu, S; Solak, H; Koca, R Özen

    2017-09-01

    Statins have cholesterol-independent effects including an increased vascular nitric oxide activity and are commonly used by patients with cardiovascular disease. Such patients frequently have cardiovascular diseases, which may be treated with cilostazol, a platelet aggregation inhibitor. This study was designed to investigate whether combined use of cilostazol would increase the inhibitory effect of statin on vascular smooth muscle and how maturation would affect these responses. Female Wistar rats, aged 3-4 months (young) and 14-15 months (adult), were sacrificed by cervical dislocation and the thoracic aorta was dissected and cut into 3- to 4-mm-long rings. The rings were mounted under a resting tension of 1 g in a 20-ml organ bath filled with Krebs-Henseleit solution. Rings were precontracted with phenylephrine (10 -6  M), and the presence of endothelium was confirmed with acetylcholine (10 -6  M). Then, the concentration-response curves were obtained for atorvastatin alone (10 -10 to 3 × 10 -4  M; control) and in the presence of cilostazol (10 -6  M) in young and adult rat aortas. This experimental protocol was also carried out in aorta rings, which had been pretreated with N G -nitro-l-arginine methyl ester (l-NAME, 10 -4  M). Atorvastatin induced concentration-dependent relaxations in young and adult rat thoracic aorta rings precontracted with phenylephrine. The pIC 50 value of atorvastatin was significantly decreased in adult rat aortas. In addition, pretreatment of aortas with cilostazol enhanced the potency of atorvastatin in both young and adult aortas. Incubation with l-NAME did not completely eliminate the relaxations to atorvastatin in the presence of cilostazol. These results suggest that combined application of cilostazol with atorvastatin was significantly more potent than atorvastatin alone. Combined drug therapy may be efficacious in delaying the occurrence of cardiovascular events.

  3. Mechanical Characterization and Material Modeling of Diabetic Aortas in a Rabbit Model.

    Science.gov (United States)

    Tong, Jianhua; Yang, F; Li, X; Xu, X; Wang, G X

    2018-03-01

    Diabetes has been recognized as a major risk factor to cause macrovascular diseases and plays a key role in aortic wall remodeling. However, the effects of diabetes on elastic properties of aortas remain largely unknown and quantitative mechanical data are lacking. Thirty adult rabbits (1.6-2.2 kg) were collected and the type 1 diabetic rabbit model was induced by injection of alloxan. A total of 15 control and 15 diabetic rabbit (abdominal) aortas were harvested. Uniaxial and biaxial tensile tests were performed to measure ultimate tensile strength and to characterize biaxial mechanical behaviors of the aortas. A material model was fitted to the biaxial experimental data to obtain constitutive parameters. Histological and mass fraction analyses were performed to investigate the underlying microstructure and dry weight percentages of elastin and collagen in the control and the diabetic aortas. No statistically significant difference was found in ultimate tensile strength between the control and the diabetic aortas. Regarding biaxial mechanical responses, the diabetic aortas exhibited significantly lower extensibility and significantly higher tissue stiffness than the control aortas. Notably, tissue stiffening occurred in both circumferential and axial directions for the diabetic aortas; however, mechanical anisotropy does not change significantly. The material model was able to fit biaxial experimental data very well. Histology showed that a number of isolated foam cells were embedded in the diabetic aortas and hyperplasia of collagen was identified. The dry weight percentages of collagen within the diabetic aortas increased significantly as compared to the control aortas, whereas no significant change was found for that of elastin. Our data suggest that the diabetes impairs elastic properties and alters microstructure of the aortas and consequently, these changes may further contribute to complex aortic wall remodeling.

  4. Calcium antagonism and the vasorelaxation of the rat aorta induced by rotundifolone

    Directory of Open Access Journals (Sweden)

    Guedes D.N.

    2004-01-01

    Full Text Available The vasorelaxing activity of rotundifolone (ROT, a major constituent (63.5% of the essential oil of Mentha x villosa, was tested in male Wistar rats (300-350 g. In isolated rat aortic rings, increasing ROT concentrations (0.3, 1, 10, 100, 300, and 500 µg/ml inhibited the contractile effects of 1 µM phenylephrine and of 80 or 30 mM KCl (IC50 values, reported as means ± SEM = 184 ± 6, 185 ± 3 and 188 ± 19 µg/ml, N = 6, respectively. In aortic rings pre-contracted with 1 µM phenylephrine, the smooth muscle-relaxant activity of ROT was inhibited by removal of the vascular endothelium (IC50 value = 235 ± 7 µg/ml, N = 6. Furthermore, ROT inhibited (pD2 = 6.04, N = 6 the CaCl2-induced contraction in depolarizing medium in a concentration-dependent manner. In Ca2+-free solution, ROT inhibited 1 µM phenylephrine-induced contraction in a concentration-dependent manner and did not modify the phasic contractile response evoked by caffeine (20 mM. In conclusion, in the present study we have shown that ROT produces an endothelium-independent vasorelaxing effect in the rat aorta. The results further indicated that in the rat aorta ROT is able to induce vasorelaxation, at least in part, by inhibiting both: a voltage-dependent Ca² channels, and b intracellular Ca2+ release selectively due to inositol 1,4,5-triphosphate activation. Additional studies are required to elucidate the mechanisms underlying ROT-induced relaxation.

  5. Tracheal replacement by autogenous aorta

    Directory of Open Access Journals (Sweden)

    Anoosh Farhad

    2009-06-01

    Full Text Available Abstract Background Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. Methods We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Results Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Conclusion Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis

  6. Tracheal replacement by autogenous aorta.

    Science.gov (United States)

    Anoosh, Farhad; Hodjati, Hossain; Dehghani, Seifollah; Tanideh, Nader; Kumar, Perikala V

    2009-06-09

    Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis.

  7. Transfer of the 3' non-translated region of grapevine chrome mosaic virus RNA-1 by recombination to tomato black ring virus RNA-2 in pseudorecombinant isolates.

    Science.gov (United States)

    Le Gall, O; Candresse, T; Dunez, J

    1995-05-01

    In grapevine chrome mosaic and tomato black ring viruses (GCMV and TBRV), as in many other nepoviruses, the 3' non-translated regions (3'NTR) are identical between the two genomic RNAs. We have investigated the structure of the 3'NTR of two recombinant isolates which contain GCMV RNA-1 and TBRV RNA-2. In these isolates, the 3'NTR of RNA-1 was transferred to RNA-2, thus restoring the 3' identity. The transfer occurred within three passages, and probably contributes to the spread of randomly appearing mutations from one genomic RNA to the other. The site of recombination is near the 3' end of the open reading frame.

  8. Ring Theory

    CERN Document Server

    Jara, Pascual; Torrecillas, Blas

    1988-01-01

    The papers in this proceedings volume are selected research papers in different areas of ring theory, including graded rings, differential operator rings, K-theory of noetherian rings, torsion theory, regular rings, cohomology of algebras, local cohomology of noncommutative rings. The book will be important for mathematicians active in research in ring theory.

  9. Cloning and sequencing of full-length cDNAs of RNA1 and RNA2 of a Tomato black ring virus isolate from Poland.

    Science.gov (United States)

    Jończyk, M; Le Gall, O; Pałucha, A; Borodynko, N; Pospieszny, H

    2004-04-01

    Full-length cDNA clones corresponding to the RNA1 and RNA2 of the Polish isolate MJ of Tomato black ring virus (TBRV, genus Nepovirus) were obtained using a direct recombination strategy in yeast, and their complete nucleotide sequences were established. RNA1 is 7358 nucleotides and RNA2 is 4633 nucleotides in length, excluding the poly(A) tails. Both RNAs contain a single open reading frame encoding polyproteins of 254 kDa and 149 kDa for RNA1 and RNA2 respectively. Putative cleavage sites were identified, and the relationships between TBRV and related nepoviruses were studied by sequence comparison.

  10. Traumatic rupture of the aorta

    International Nuclear Information System (INIS)

    Dorfman, G.S.; Paolella, L.P.; Haas, R.A.; Lambiase, R.E.; Cronan, J.J.

    1988-01-01

    To evaluate the acceptability of digital subtraction angiography (DSA) in the evaluation of traumatic rupture of the aorta (TRA), the authors obtained 56 thoracic aortograms in 55 consecutive trauma patients, using both DSA and cut-film angiography (CFA). Both studies were ranked blindly and assigned scores for quality and diagnosis. Interobserver variance for DSA and CFA quality rankings was insignificant. CFA achieved significantly higher ranking for quality. In the 56 examinations, CFA demonstrated seven abnormalities that demanded intervention for follow-up angiography. DSA demonstrated only five of these and found no additional abnormalities. While this evaluation applies only to the particular digital system that the authors tested, they found that DSA, as compared with CFA, failed to demonstrate significant aortic injury. The confidence of diagnosis was significantly greater with CFA. Similar double-blind evaluation is mandatory at any trauma center prior to converting from CFA to DSA in the diagnosis of this life-threatening condition

  11. Experimental Gestational Diabetes Mellitus Induces Blunted Vasoconstriction and Functional Changes in the Rat Aorta

    Directory of Open Access Journals (Sweden)

    Cecilia Tufiño

    2014-01-01

    Full Text Available Diabetic conditions increase vascular reactivity to angiotensin II in several studies but there are scarce reports on cardiovascular effects of hypercaloric diet (HD induced gestational diabetes mellitus (GDM, so the objective of this work was to determine the effects of HD induced GDM on vascular responses. Angiotensin II as well as phenylephrine induced vascular contraction was tested in isolated aorta rings with and without endothelium from rats fed for 7 weeks (4 before and 3 weeks during pregnancy with standard (SD or hypercaloric (HD diet. Also, protein expression of AT1R, AT2R, COX-1, COX-2, NOS-1, and NOS-3 and plasma glucose, insulin, and angiotensin II levels were measured. GDM impaired vasoconstrictor response (P<0.05 versus SD in intact (e+ but not in endothelium-free (e− vessels. Losartan reduced GDM but not SD e− vasoconstriction (P<0.01 versus SD. AT1R, AT2R, and COX-1 and COX-2 protein expression were significantly increased in GDM vessels (P<0.05 versus SD. Results suggest an increased participation of endothelium vasodilator mediators, probably prostaglandins, as well as of AT2 vasodilator receptors as a compensatory mechanism for vasoconstrictor changes generated by experimental GDM. Considering the short term of rat pregnancy findings can reflect early stage GDM adaptations.

  12. Chronic cigarette smoke exposure adversely alters 14C-arachidonic acid metabolism in rat lungs, aortas and platelets

    International Nuclear Information System (INIS)

    Lubawy, W.C.; Valentovic, M.A.; Atkinson, J.E.; Gairola, G.C.

    1983-01-01

    Male rats were exposed to freshly generated cigarette smoke once daily, 5 times a week for 10 weeks. Inhalation of smoke was verified by elevated carboxyhemoglobin in blood sampled immediately after smoke exposure and by increased lung aryl hydrocarbon hydroxylase activity 24 hours after the last smoke exposure. Aortic rings isolated from smoke-exposed rats synthesized less prostacyclin (PGI2) from 14 C-arachidonic acid than rings from sham rats. Platelets from smoke-exposed rats synthesized more thromboxane (TXA2) from 14 C-arachidonic acid than platelets from room controls but not those from sham rats. Lung microsomes from smoke-exposed rats synthesized more TXA2 and had a lower PGI2/TXA2 ratio than lung microsomes from room controls and shams. It is concluded that chronic cigarette smoke exposure alters arachidonic acid metabolism in aortas, platelets and lungs in a manner resulting in decreased PGI2 and increased TXA2, thereby creating a condition favoring platelet aggregation and a variety of cardiovascular diseases

  13. The nucleotide sequence of the RNA-2 of an isolate of the English serotype of tomato black ring virus: RNA recombination in the history of nepoviruses.

    Science.gov (United States)

    Le Gall, O L; Lanneau, M; Candresse, T; Dunez, J

    1995-05-01

    The RNA-2 of a carrot isolate from the English serotype of tomato black ring nepovirus (TBRV-ED) has been sequenced. It is 4618 nucleotides long and contains one open reading frame encoding a polypeptide of 1344 amino acids. The 5' non-coding region contains three repetitions of a stem-loop structure also conserved in TBRV-Scottish and grapevine chrome mosaic nepovirus (GCMV). The coat protein domain was mapped to the carboxy-terminal one-third of the polyprotein. Sequence comparisons indicate that TBRV-ED RNA-2 probably arose by an RNA recombination event that resulted in the exchange of the putative movement protein gene between TBRV and GCMV.

  14. Isolation and Characterization of Three and Four Ring Pahs Degrading Bacteria from Contaminated Sites, Ankleshwar, Gujarat, India

    Directory of Open Access Journals (Sweden)

    Jignasha G. Patel

    2015-02-01

    Full Text Available Polycyclic aromatic hydrocarbon (PAH-degrading bacteria were isolated from prolong contaminated Amalakhadi sediment and crude oil polluted soil Telva, near Ankleshwar Gujarat India. Organisms were treated with two-model PAHs compound Anthracene (ANT, and Pyrene (PYR as the sole source of carbon and energy. Identification of the isolates was carried out based on their morphological and partial 16S rRNA gene sequences, which revealed that the isolates belong to two main bacterial groups: gram-negative pseudomonas indoxyladons and gram-positive, spore-forming group, Bacillus benzoevorans. GC-MS based degradation study demonstrated that P. indoxyladons efficiently degrade 98% of ANT and PYR by 93.2 % when treated with 250 mg L-1. However, B. benzoevorans could tolerate to 200 mg L-1of PYR. Thus, the findings of the study provide novel bacterial sp. having different capacity to degrade model PAHs compounds and further could be utilized for the standardization of bioremediation protocols for ex situ and in situ studies in aquatic as well as terrestrial ecosystem.DOI: http://dx.doi.org/10.3126/ije.v4i1.12184International Journal of Environment Volume-4, Issue-1, Dec-Feb 2014/15, Page: 130-140  

  15. Ramos colaterais parietais e terminais da aorta abdominal em Myocastor coypus (nutria Terminal and parietal colateral branches of the abdominal aorta in Myocastor coypus (nutria

    Directory of Open Access Journals (Sweden)

    Paulete de Oliveira Vargas Culau

    2008-08-01

    , in order to irrigate part of the diaphragm and the cranial lateral abdominal walls. The abdominal aorta emitted, dorsally, the median sacral artery, cranially to its bifurcation into the common iliac arteries. These common iliac arteries, terminal branches of the aorta, originate the internal and external iliac arteries. The internal iliac artery was distributed along the pelvic cavity viscera. The external iliac artery emitted an umbilical artery and, before reaching the inguinal ring, emitted the deep circunflex iliac artery to 2/3 of the caudal lateral abdominal wall. The external iliac artery emitted the pudendoepigastric trunk, wich has originated the caudal epigastric artery, to the ventral abdominal wall, and the external pudendal artery, wich passed through the inguinal ring to irrigate the external genital. The direct parietal branches of the abdominal aorta were the lumbar arteries and the median sacral artery, while the phrenicoabdominal arteries, deep circunflex iliac and the caudal epigastric artery were indirect colateral parietal branches. The terminal branches of the abdominal aorta were the common iliac arteries with its branches, the internal and external iliac arteries.

  16. Human Aorta Is a Passive Pump

    Science.gov (United States)

    Pahlevan, Niema; Gharib, Morteza

    2012-11-01

    Impedance pump is a simple valveless pumping mechanism that operates based on the principles of wave propagation and reflection. It has been shown in a zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. Our aim in this study was to examine if the human aorta is a passive pump working like an impedance pump. A hydraulic model with different compliant models of artificial aorta was used for series of in-vitro experiments. The hydraulic model includes a piston pump that generates the waves. Our result indicates that wave propagation and reflection can create pumping mechanism in a compliant aorta. Similar to an impedance pump, the net flow and the flow direction depends on the frequency of the waves, compliance of the aorta, and the piston stroke.

  17. Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry

    Science.gov (United States)

    Keshavarz-Motamed, Zahra; Garcia, Julio; Gaillard, Emmanuel; Maftoon, Nima; Di Labbio, Giuseppe; Cloutier, Guy; Kadem, Lyes

    2014-03-01

    Blood flow in the aorta has been of particular interest from both fluid dynamics and physiology perspectives. Coarctation of the aorta (COA) is a congenital heart disease corresponding to a severe narrowing in the aortic arch. Up to 85 % of patients with COA have a pathological aortic valve, leading to a narrowing at the valve level. The aim of the present work was to advance the state of understanding of flow through a COA to investigate how narrowing in the aorta (COA) affects the characteristics of the velocity field and, in particular, turbulence development. For this purpose, particle image velocimetry measurements were conducted at physiological flow and pressure conditions, with three different aorta configurations: (1) normal case: normal aorta + normal aortic valve; (2) isolated COA: COA (with 75 % reduction in aortic cross-sectional area) + normal aortic valve and (3) complex COA: COA (with 75 % reduction in aortic cross-sectional area) + pathological aortic valve. Viscous shear stress (VSS), representing the physical shear stress, Reynolds shear stress (RSS), representing the turbulent shear stress, and turbulent kinetic energy (TKE), representing the intensity of fluctuations in the fluid flow environment, were calculated for all cases. Results show that, compared with a healthy aorta, the instantaneous velocity streamlines and vortices were deeply changed in the presence of the COA. The normal aorta did not display any regions of elevated VSS, RSS and TKE at any moment of the cardiac cycle. The magnitudes of these parameters were elevated for both isolated COA and complex COA, with their maximum values mainly being located inside the eccentric jet downstream of the COA. However, the presence of a pathologic aortic valve, in complex COA, amplifies VSS (e.g., average absolute peak value in the entire aorta for a total flow of 5 L/min: complex COA: = 36 N/m2; isolated COA = 19 N/m2), RSS (e.g., average peak value in the entire aorta for a total flow of 5

  18. Black rings

    International Nuclear Information System (INIS)

    Emparan, Roberto; Reall, Harvey S

    2006-01-01

    A black ring is a five-dimensional black hole with an event horizon of topology S 1 x S 2 . We provide an introduction to the description of black rings in general relativity and string theory. Novel aspects of the presentation include a new approach to constructing black ring coordinates and a critical review of black ring microscopics. (topical review)

  19. Investigation of the role of the NO-cGMP pathway on YC-1 and DEA/NO effects on thoracic aorta smooth muscle responses in a rat preeclampsia model.

    Science.gov (United States)

    Turgut, Nergiz Hacer; Temiz, Tijen Kaya; Turgut, Bülent; Karadas, Baris; Parlak, Mesut; Bagcivan, Ihsan

    2013-10-01

    The present study was designed to investigate the effects of YC-1, a nitric oxide (NO)-independent soluble guanylate cyclase (sGC) activator, and DEA/NO, a NO donor, on smooth muscle responses in the preeclampsia model with suramin-treated rats and on the levels of cyclic guanosine monophosphate (cGMP) of thoracic aorta rings isolated from term-pregnant rats. Rats of 2 groups, control group and suramin group, were given intraperitoneal injection of saline or suramin, respectively. Suramin injection caused increased blood pressure, protein in urine, and fetal growth retardation. Thoracic aorta rings were exposed to contractile and relaxant agents. KCl contraction and papaverine relaxation responses were similar. Relaxation responses of YC-1 and DEA/NO decreased in suramin group. In both groups in the presence of ODQ, a sGC inhibitor, the relaxation responses of YC-1 and DEA/NO decreased. The cGMP content was determined by radioimmunoassay technique. The content of cGMP in the suramin group decreased. In the presence of YC-1 and DEA/NO in both groups, cGMP content increased, but in ODQ-added groups, there was a significant decrease. We conclude that in preeclampsia, the decrease of relaxation responses and the decrease of cGMP content could be due to the reduction in stimulation of sGC and the decrease in cGMP levels.

  20. White Ring; White ring

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, H.; Yuzawa, H. [Nikken Sekkei Ltd., Osaka (Japan)

    1998-01-05

    White Ring is a citizen`s gymnasium used for figure skating and short track speed skating games of 18th Winter Olympic Games in 1998. White Ring is composed of a main-arena and a sub-arena. For the main-arena with an area 41mtimes66m, an ice link can be made by disengaging the potable floor and by flowing brine in the bridged polystyrene pipes embedded in the concrete floor. Due to the fortunate groundwater in this site, well water is used for the outside air treatment energy in 63% during heating and in 35% during cooling. Ammonia is used as a cooling medium for refrigerating facility. For the heating of audience area in the large space, heat load from the outside is reduced by enhancing the heat insulation performance of the roof of arena. The audience seats are locally heated using heaters. For the White Ring, high quality environment is realized for games through various functions of the large-scale roof of the large space. Success of the big event was expected. 15 figs., 4 tabs.

  1. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  2. Extended replacement of the thoracic aorta.

    Science.gov (United States)

    Hino, Yutaka; Okada, Kenji; Oka, Takanori; Inoue, Takeshi; Tanaka, Akiko; Omura, Atsushi; Kano, Hiroya; Okita, Yutaka

    2013-01-01

    We present our experience of total aortic arch replacement. Twenty-nine patients (21 males and 8 females; mean age 63.3 ± 13.3 years) with extended thoracic aortic aneurysms underwent graft replacement. The pathology of the diseased aorta was non-dissecting aneurysm in 11 patients, including one aortitis and aortic dissection in 18 patients (acute type A: one, chronic type A: 11, chronic type B: six). Five patients had Marfan syndrome. In their previous operation, two patients had undergone the Bentall procedure, three had endovascular stenting, one had aortic root replacement with valve sparing and 12 had hemi-arch replacement for acute type A dissection. Approaches to the aneurysm were as follows: posterolateral thoracotomy with rib-cross incision in 16, posterolateral thoracotomy extended to the retroperitoneal abdominal aorta in seven, mid-sternotomy and left pleurotomy in three, anterolateral thoracotomy with partial lower sternotomy in two and clam-shell incision in one patient. Extension of aortic replacement was performed from the aortic root to the descending aorta in 4, from the ascending aorta to the descending aorta in 17 and from the ascending to the abdominal aorta in eight patients. Arterial inflow for cardiopulmonary bypass consisted of the femoral artery in 15 patients, ascending aorta and femoral artery in seven, descending or abdominal aorta in five and ascending aorta in two. Venous drainage site was the femoral vein in 10, pulmonary artery in eight, right atrium in five, femoral artery with right atrium/pulmonary artery in four and pulmonary artery with right atrium in two patients. The operative mortality, 30-day mortality and hospital mortality was one (cardiac arrest due to aneurysm rupture), one (rupture of infected aneurysm) and one (brain contusion), respectively. Late mortality occurred in three patients due to pneumonia, ruptured residual aneurysm and intracranial bleeding. Actuarial survival at 5 years after the operations was 80.6

  3. Vortex rings

    CERN Document Server

    Akhmetov, D G

    2009-01-01

    This text on vortex rings covers their theoretical foundation, systematic investigations, and practical applications such as the extinction of fires at gushing oil wells. It pays special attention to the formation and motion of turbulent vortex rings.

  4. Arma branca retida em aorta abdominal superior

    Directory of Open Access Journals (Sweden)

    Fernando Antonio C. Spencer Netto

    Full Text Available Abdominal aorta wounds carries a high immediate mortality. Few patients reach hospital care alive. There are no reports on Medline (1969-2002 about aortic wounds of foreign body with retention. A case with upper abdominal aortic wound with an inlaid blade is reported. The retained blade fixed the stomach to the surgical field, difficulting the vascular control, leading to an unconventional approach and allowing extensive contamination. The patient developed multiple organ dysfunction and died at fifth postoperative day. Singularities of an inlaid knife in upper abdominal aorta and changes in traditional approach are discussed. The authors assumed that the inlaid knife decreased the bleeding, allowing the patient arrival to the hospital, but worsened the approach to the aorta wound.

  5. Pseudoprominent aorta: Radiographic findings and CT correlation

    International Nuclear Information System (INIS)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-01-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented

  6. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  7. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  8. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  9. Inhibition of PKC-dependent extracellular Ca2+ entry contributes to the depression of contractile activity in long-term pressure-overloaded endothelium-denuded rat aortas

    International Nuclear Information System (INIS)

    Padilla, J.; López, R.M.; López, P.; Castillo, M.C.; Querejeta, E.; Ruiz, A.; Castillo, E.F.

    2014-01-01

    We examined the contractile responsiveness of rat thoracic aortas under pressure overload after long-term suprarenal abdominal aortic coarctation (lt-Srac). Endothelium-dependent angiotensin II (ANG II) type 2 receptor (AT 2 R)-mediated depression of contractions to ANG II has been reported in short-term (1 week) pressure-overloaded rat aortas. Contractility was evaluated in the aortic rings of rats subjected to lt-Srac or sham surgery (Sham) for 8 weeks. ANG I and II levels and AT 2 R protein expression in the aortas of lt-Srac and Sham rats were also evaluated. lt-Srac attenuated the contractions of ANG II and phenylephrine in the aortas in an endothelium-independent manner. However, lt-Srac did not influence the transient contractions induced in endothelium-denuded aortic rings by ANG II, phenylephrine, or caffeine in Ca 2+ -free medium or the subsequent tonic constrictions induced by the addition of Ca 2+ in the absence of agonists. Thus, the contractions induced by Ca 2+ release from intracellular stores and Ca 2+ influx through stored-operated channels were not inhibited in the aortas of lt-Srac rats. Potassium-elicited contractions in endothelium-denuded aortic rings of lt-Srac rats remained unaltered compared with control tissues. Consequently, the contractile depression observed in aortic tissues of lt-Srac rats cannot be explained by direct inhibition of voltage-operated Ca 2+ channels. Interestingly, 12-O-tetradecanoylphorbol-13-acetate-induced contractions in endothelium-denuded aortic rings of lt-Srac rats were depressed in the presence but not in the absence of extracellular Ca 2+ . Neither levels of angiotensins nor of AT 2 R were modified in the aortas after lt-Srac. The results suggest that, in rat thoracic aortas, lt-Srac selectively inhibited protein kinase C-mediated activation of contraction that is dependent on extracellular Ca 2+ entry

  10. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  11. Coarctation Long-term Assessment (COALA): significance of arterial hypertension in a cohort of 404 patients up to 27 years after surgical repair of isolated coarctation of the aorta, even in the absence of restenosis and prosthetic material.

    Science.gov (United States)

    Hager, Alfred; Kanz, Simone; Kaemmerer, Harald; Schreiber, Christian; Hess, John

    2007-09-01

    Recent studies have demonstrated that there is a loss of aortic compliance in patients after coarctation repair. The clinical effect of this and other mechanisms apart from restenosis on the rate of arterial hypertension is unknown. From 1974 through 2000, 404 patients born before January 1, 1985, underwent surgical intervention for isolated aortic coarctation. From those 382 who are still alive, 273 patients aged 16 to 73 years (1-27 years after surgical intervention) underwent a structured clinical investigation according to a prospective protocol, including blood pressure measurement at all limbs, ambulatory blood pressure measurement, and symptom-limited exercise testing. Sixty-seven (25%) patients were already taking antihypertensive drugs, and another 63 (23%) patients had an increased ambulatory blood pressure. Still another 26 (10%) patients had a blood pressure during exercise exceeding 2 standard deviations of reference values. Only 117 (43%) patients had a normal blood pressure reaction. From those 156 patients with hypertension, only 21 (13%) had a systolic brachial-ankle blood pressure difference of greater than 20 mm Hg, suggesting restenosis. In the patient group without restenosis (n = 245), independent risk factors for hypertension were repair with prosthetic material, male sex, a residual brachial-ankle blood pressure difference, and older age at follow-up. The majority of patients were hypertensive at long-term follow-up after coarctation repair. This is caused by restenosis, defined by a gradient of greater than 20 mm Hg, in only a few patients. Even in those without prosthetic material or minimal-grade restenosis, there is a substantial incidence of arterial hypertension.

  12. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM).

    Science.gov (United States)

    Moriwaki, Takeshi; Oie, Tomonori; Takamizawa, Keiichi; Murayama, Yoshinobu; Fukuda, Toru; Omata, Sadao; Kanda, Keiichi; Nakayama, Yasuhide

    2011-12-01

    Variations in microscopic elastic structures along the entire length of canine aorta were evaluated by use of a scanning haptic microscope (SHM). The total aorta from the aortic arch to the abdominal aorta was divided into 6 approximately equal segments. After embedding the aorta in agar, it was cut into horizontal circumferential segments to obtain disk-like agar portions containing ring-like samples of aorta with flat surfaces (thickness, approximately 1 mm). The elastic modulus and topography of the samples under no-load conditions were simultaneously measured along the entire thickness of the wall by SHM by using a probe with a diameter of 5 μm and a spatial resolution of 2 μm at a rate of 0.3 s/point. The elastic modulus of the wall was the highest on the side of the luminal surface and decreased gradually toward the adventitial side. This tendency was similar to that of the change in the elastin fiber content. During the evaluation of the mid-portion of each tunica media segment, the highest elastic modulus (40.8 ± 3.5 kPa) was identified at the thoracic section of the aorta that had the highest density of elastic fibers. Under no-load conditions, portions of the aorta with high elastin density have a high elastic modulus.

  13. Mechanisms underlying sodium nitroprusside-induced tolerance in the mouse aorta: Role of ROS and cyclooxygenase-derived prostanoids.

    Science.gov (United States)

    Diniz, Mariana C; Olivon, Vania C; Tavares, Lívia D; Simplicio, Janaina A; Gonzaga, Natália A; de Souza, Daniele G; Bendhack, Lusiane M; Tirapelli, Carlos R; Bonaventura, Daniella

    2017-05-01

    To determine the role of reactive oxygen species (ROS) on sodium nitroprusside (SNP)-induced tolerance. Additionally, we evaluated the role of ROS on NF-κB activation and pro-inflammatory cytokines production during SNP-induced tolerance. To induce in vitro tolerance, endothelium-intact or -denuded aortic rings isolated from male Balb-c mice were incubated for 15, 30, 45 or 60min with SNP (10nmol/L). Tolerance to SNP was observed after incubation of endothelium-denuded, but not endothelium-intact aortas for 60min with this inorganic nitrate. Pre-incubation of denuded rings with tiron (superoxide anion (O 2 - ) scavenger), and the NADPH oxidase inhibitors apocynin and atorvastatin reversed SNP-induced tolerance. l-NAME (non-selective NOS inhibitor) and l-arginine (NOS substrate) also prevented SNP-induced tolerance. Similarly, ibuprofen (non-selective cyclooxygenase (COX) inhibitor), nimesulide (selective COX-2 inhibitor), AH6809 (prostaglandin PGF 2 α receptor antagonist) or SQ29584 [PGH 2 /thromboxane TXA 2 receptor antagonist] reversed SNP-induced tolerance. Increased ROS generation was detected in tolerant arteries and both tiron and atorvastatin reversed this response. Tiron prevented tolerance-induced increase on O 2 - and hydrogen peroxide (H 2 O 2 ) levels. The increase onp65/NF-κB expression and TNF-α production in tolerant arteries was prevented by tiron. The major new finding of our study is that SNP-induced tolerance is mediated by NADPH-oxidase derived ROS and vasoconstrictor prostanoids derived from COX-2, which are capable of reducing the vasorelaxation induced by SNP. Additionally, we found that ROS mediate the activation of NF-κB and the production of TNF-α in tolerant arteries. These findings identify putative molecular mechanisms whereby SNP induces tolerance in the vasculature. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The normal distribution of thoracoabdominal aorta small branch artery ostia

    International Nuclear Information System (INIS)

    Cronin, Paul; Williams, David M.; Vellody, Ranjith; Kelly, Aine Marie; Kazerooni, Ella A.; Carlos, Ruth C.

    2011-01-01

    The purpose of this study was to determine the normal distribution of aortic branch artery ostia. CT scans of 100 subjects were retrospectively reviewed. The angular distributions of the aorta with respect to the center of the T3 to L4 vertebral bodies, and of branch artery origins with respect to the center of the aorta were measured. At each vertebral body level the distribution of intercostal/lumbar arteries and other branch arteries were calculated. The proximal descending aorta is posteriorly placed becoming a midline structure, at the thoracolumbar junction, and remains anterior to the vertebral bodies within the abdomen. The intercostal and lumbar artery ostia have a distinct distribution. At each vertebral level from T3 caudally, one intercostal artery originates from the posterior wall of the aorta throughout the thoracic aorta, while the other intercostal artery originates from the medial wall of the descending thoracic aorta high in the chest, posteromedially from the mid-thoracic aorta, and from the posterior wall of the aorta low in the chest. Mediastinal branches of the thoracic aorta originate from the medial and anterior wall. Lumbar branches originate only from the posterior wall of the abdominal aorta. Aortic branch artery origins arise with a bimodal distribution and have a characteristic location. Mediastinal branches of the thoracic aorta originate from the medial and anterior wall. Knowing the location of aortic branch artery ostia may help distinguish branch artery pseudoaneurysms from penetrating ulcers.

  15. Structure and dynamics of ringed galaxies

    International Nuclear Information System (INIS)

    Buta, R.J.

    1984-01-01

    In many spiral and SO galaxies, single or multiple ring structures are visible in the disk. These inner rings (r), outer rings (R), and nuclear rings (nr) were investigated by means of morphology, photometry, and spectroscopy in order to provide basic data on a long neglected phenomenon. The metric properties of each ring are investigated and found to correlate with the structure of the parent galaxy. When properly calibrated, inner rings in barred (SB) systems can be used as geometric extragalactic distance indicators to distances in excess of 100 Mpc. Other statistics are presented that confirm previous indications that the rings have preferred shapes, relative sizes, and orientations with respect to bars. A survey is made of the less homogeneous non-barred (SA) ringed systems, and the causes of the inhomogeneity are isolated. It is shown that rings can be identified in multiple-ring SA systems that are exactly analogous to those in barred spirals

  16. Device occlusion of pseudoaneurysm of ascending aorta

    International Nuclear Information System (INIS)

    Agarwal, Mridul; Ray, Mili; Pallavi, M; Sen, Supratim; Ganguly, Debosree; Joshi, Pankaj; Tanti, Sanjay; Chattopadhyay, Amitabh; Bandyopadhyay, Biswajit

    2011-01-01

    Pseudoaneurysm of ascending aorta is an infrequent but well-recognized and potentially fatal complication after cardiac surgeries. The complication can develop early, delayed or late, and the presentation is also varied. We are presenting here two cases of pseudoaneurysm of ascending aorta following cardiac surgery that were successfully managed by the transcatheter method. The first one occurred following coronary artery bypass surgery and the second one occurred following double-valve replacement surgery. The aortic openings of these aneurysms were occluded with 12 mm and 10 mm atrial septal occluders, respectively, with a good outcome. An immediate postprocedure angiogram showed no residual flow into the sac. Six months of follow-up of both cases also showed excellent results

  17. Diagnosis of supravalvar stenosis of aorta

    International Nuclear Information System (INIS)

    Shumskij, V.I.; Konstantinova, N.V.; Pokidkin, V.A.

    1989-01-01

    The authors analyzed the potentialities of combined radiodiagnosis of supravalvar stenosis (SS) and concomitant diseases of the heart and major vessels (Williams-Beuren syndrome) in 7 patients aged 7 mos. to 24 yrs. Polypositional chest and heart X-ray procedure, catheterization of the cardiac cavities, pulmonary artery and aorta, left ventriculography (6), right ventriculography (4) and angiopulmonography were used. The diagnostic potentialities of each method were defined

  18. Aorta Fluorescence Imaging by Using Confocal Microscopy

    OpenAIRE

    Wang, Chun-Yang; Tsai, Jui-che; Chuang, Ching-Cheng; Hsieh, Yao-Sheng; Sun, Chia-Wei

    2011-01-01

    The activated leukocyte attacked the vascular endothelium and the associated increase in VEcadherin number was observed in experiments. The confocal microscopic system with a prism-based wavelength filter was used for multiwavelength fluorescence measurement. Multiwavelength fluorescence imaging based on the VEcadherin within the aorta segment of a rat was achieved. The confocal microscopic system capable of fluorescence detection of cardiovascular tissue is a useful tool for measuring the bi...

  19. Stress Alone or associated with Ethanol Induces Prostanoid Release in Rat Aorta via α2-Adrenoceptor

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Rafaela de Fátima Ferreira [Departamento de Farmacologia - Instituto de Biociências - Universidade Estadual Paulista - UNESP - São Paulo, SP (Brazil); Laboratório de Farmacologia - Faculdade de Medicina de Marília - FAMEMA, SP (Brazil); Taipeiro, Elane de Fátima [Laboratório de Farmacologia - Faculdade de Medicina de Marília - FAMEMA, SP (Brazil); Queiroz, Regina Helena Costa [Departamento de Análise Clínica - Toxicológica e Ciência de Alimentos - Faculdade de Ciências Farmacêuticas - USP, São Paulo, SP (Brazil); Chies, Agnaldo Bruno [Departamento de Farmacologia - Instituto de Biociências - Universidade Estadual Paulista - UNESP - São Paulo, SP (Brazil); Laboratório de Farmacologia - Faculdade de Medicina de Marília - FAMEMA, SP (Brazil); Cordellini, Sandra, E-mail: cordelli@ibb.unesp.br [Departamento de Farmacologia - Instituto de Biociências - Universidade Estadual Paulista - UNESP - São Paulo, SP (Brazil)

    2014-03-15

    Stress and ethanol are both, independently, important cardiovascular risk factors. To evaluate the cardiovascular risk of ethanol consumption and stress exposure, isolated and in association, in male adult rats. Rats were separated into 4 groups: Control, ethanol (20% in drinking water for 6 weeks), stress (immobilization 1h day/5 days a week for 6 weeks) and stress/ethanol. Concentration-responses curves to noradrenaline - in the absence and presence of yohimbine, L-NAME or indomethacin - or to phenylephrine were determined in thoracic aortas with and without endothelium. EC50 and maximum response (n=8-12) were compared using two-way ANOVA/Bonferroni method. Either stress or stress in association with ethanol consumption increased the noradrenaline maximum responses in intact aortas. This hyper-reactivity was eliminated by endothelium removal or by the presence of either indomethacin or yohimbine, but was not altered by the presence of L-NAME. Meanwhile, ethanol consumption did not alter the reactivity to noradrenaline. The phenylephrine responses in aortas both with and without endothelium also remained unaffected regardless of protocol. Chronic stress increased rat aortic responses to noradrenaline. This effect is dependent upon the vascular endothelium and involves the release of vasoconstrictor prostanoids via stimulation of endothelial alpha-2 adrenoceptors. Moreover, chronic ethanol consumption appeared to neither influence noradrenaline responses in rat thoracic aorta, nor did it modify the increase of such responses observed as a consequence of stress exposure.

  20. Stress Alone or associated with Ethanol Induces Prostanoid Release in Rat Aorta via α2-Adrenoceptor

    International Nuclear Information System (INIS)

    Baptista, Rafaela de Fátima Ferreira; Taipeiro, Elane de Fátima; Queiroz, Regina Helena Costa; Chies, Agnaldo Bruno; Cordellini, Sandra

    2014-01-01

    Stress and ethanol are both, independently, important cardiovascular risk factors. To evaluate the cardiovascular risk of ethanol consumption and stress exposure, isolated and in association, in male adult rats. Rats were separated into 4 groups: Control, ethanol (20% in drinking water for 6 weeks), stress (immobilization 1h day/5 days a week for 6 weeks) and stress/ethanol. Concentration-responses curves to noradrenaline - in the absence and presence of yohimbine, L-NAME or indomethacin - or to phenylephrine were determined in thoracic aortas with and without endothelium. EC50 and maximum response (n=8-12) were compared using two-way ANOVA/Bonferroni method. Either stress or stress in association with ethanol consumption increased the noradrenaline maximum responses in intact aortas. This hyper-reactivity was eliminated by endothelium removal or by the presence of either indomethacin or yohimbine, but was not altered by the presence of L-NAME. Meanwhile, ethanol consumption did not alter the reactivity to noradrenaline. The phenylephrine responses in aortas both with and without endothelium also remained unaffected regardless of protocol. Chronic stress increased rat aortic responses to noradrenaline. This effect is dependent upon the vascular endothelium and involves the release of vasoconstrictor prostanoids via stimulation of endothelial alpha-2 adrenoceptors. Moreover, chronic ethanol consumption appeared to neither influence noradrenaline responses in rat thoracic aorta, nor did it modify the increase of such responses observed as a consequence of stress exposure

  1. Tratamiento endoluminal de la aorta. Implicaciones en la enfermedad de la aorta torácica

    Directory of Open Access Journals (Sweden)

    Miguel Josa García-Tornel

    2007-10-01

    Full Text Available Durante los últimos años el tratamiento quirúrgico endoluminal de la enfermedad de la aorta (EVAR, endovascular aortic repair se ha convertido en una opción terapéutica en un espectro amplio de pacientes. EVAR es una técnica relativamente fácil, menos agresiva y con aparente menor riesgo con respecto a la cirugía convencional de la aorta. La evidente presión de la industria, a menudo combinada con el lógico interés por su desarrollo por parte de muchos grupos clínicos y el factor moda, tan en boga en nuestros tiempos, han dado a la cirugía endoluminal de la aorta abdominal un desarrollo muy rápido que se está extendiendo en la actualidad a segmentos de la aorta torácica. Aunque los resultados publicados parecen avalar un papel importante de EVAR en algunos grupos específicos de pacientes, su uso en muchos otros grupos es muy controvertido. Su alto coste y los resultados a medio plazo parecen poner en tela de juicio la tendencia a la generalización que existe hoy día. La aplicación a la aorta torácica está asociada con un mayor número de interrogantes. Estudios rigurosos y mejoras técnicas ayudarán, sin duda, a definir mejor su indudable aplicabilidad en el tratamiento de la aorta tanto abdominal como torácica, pero en la actualidad su uso debe estar regulado por un cumplimiento estricto de indicaciones basadas en evidencias clínicas y alejadas de otros intereses, y su práctica debe reducirse a grupos de multiespecialidad preparados en todos los aspectos de la cirugía cardiovascular.

  2. Aktivitas Kontraktilitas Aorta Pada Ekstrak Daun Androgrophis Paniculata

    OpenAIRE

    Kosala, Khemasili; Ismail, Sjarif

    2008-01-01

    Andrographis paniculata leaves are often used as an anti-hypertension medicine. However, its effects in the blood vessels are not clearly known. This research was aimed to measure the activities of Andrographis paniculata leaves extract on blood vessels contractility. Andrographis paniculata leaves were macerated with CHCl3: Me-OH (1:1), and tested for ther effects on the contractility of the isolated organ of rabbit's aortic ring with endothelium. The result showed that Andrographis panicul...

  3. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  4. ring system

    African Journals Online (AJOL)

    1,3,2-DIAZABORACYCLOALKANE. RING SYSTEM. Negussie Retta" and Robert H. Neilson. 'Department of Chemistry, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia. Department of Chemistry, Texas Christian University.

  5. Planetary Rings

    Science.gov (United States)

    Nicholson, P. D.

    2001-11-01

    A revolution in the studies in planetary rings studies occurred in the period 1977--1981, with the serendipitous discovery of the narrow, dark rings of Uranus, the first Voyager images of the tenuous jovian ring system, and the many spectacular images returned during the twin Voyager flybys of Saturn. In subsequent years, ground-based stellar occultations, HST observations, and the Voyager flybys of Uranus (1986) and Neptune (1989), as well as a handful of Galileo images, provided much additional information. Along with the completely unsuspected wealth of detail these observations revealed came an unwelcome problem: are the rings ancient or are we privileged to live at a special time in history? The answer to this still-vexing question may lie in the complex gravitational interactions recent studies have revealed between the rings and their retinues of attendant satellites. Among the four known ring systems, we see elegant examples of Lindblad and corotation resonances (first invoked in the context of galactic disks), electromagnetic resonances, spiral density waves and bending waves, narrow ringlets which exhibit internal modes due to collective instabilities, sharp-edged gaps maintained via tidal torques from embedded moonlets, and tenuous dust belts created by meteoroid impact onto parent bodies. Perhaps most puzzling is Saturn's multi-stranded, clumpy F ring, which continues to defy a simple explanation 20 years after it was first glimpsed in grainy images taken by Pioneer 11. Voyager and HST images reveal a complex, probably chaotic, dynamical interaction between unseen parent bodies within this ring and its two shepherd satellites, Pandora and Prometheus. The work described here reflects contributions by Joe Burns, Jeff Cuzzi, Luke Dones, Dick French, Peter Goldreich, Colleen McGhee, Carolyn Porco, Mark Showalter, and Bruno Sicardy, as well as those of the author. This research has been supported by NASA's Planetary Geology and Geophysics program and the

  6. Measuring the Contractile Response of Isolated Tissue Using an Image Sensor

    Directory of Open Access Journals (Sweden)

    David Díaz-Martín

    2015-04-01

    Full Text Available Isometric or isotonic transducers have traditionally been used to study the contractile/relaxation effects of drugs on isolated tissues. However, these mechanical sensors are expensive and delicate, and they are associated with certain disadvantages when performing experiments in the laboratory. In this paper, a method that uses an image sensor to measure the contractile effect of drugs on blood vessel rings and other luminal organs is presented. The new method is based on an image-processing algorithm, and it provides a fast, easy and non-expensive way to analyze the effects of such drugs. In our tests, we have obtained dose-response curves from rat aorta rings that are equivalent to those achieved with classical mechanic sensors.

  7. Vasodilator effects and putative guanylyl cyclase stimulation by 2-nitro-1-phenylethanone and 2-nitro-2-phenyl-propane-1,3-diol on rat aorta.

    Science.gov (United States)

    Vasconcelos, Thiago Brasileiro de; Ribeiro-Filho, Helder Veras; Lahlou, Saad; Pereira, José Geraldo de Carvalho; Oliveira, Paulo Sérgio Lopes de; Magalhães, Pedro Jorge Caldas

    2018-07-05

    Compounds containing a nitro group may reveal vasodilator properties. Several nitro compounds have a NO 2 group in a short aliphatic chain connected to an aromatic group. In this study, we evaluated in rat aorta the effects of two nitro compounds, with emphasis on a putative recruitment of the soluble guanylate cyclase (sGC) pathway to induce vasodilation. Isolated aortic rings were obtained from male Wistar rats to compare the effects induced by 2-nitro-1-phenylethanone (NPeth) or 2-nitro-2-phenyl-propane-1,3-diol (NPprop). In aortic preparations contracted with phenylephrine or KCl, NPeth and NPprop induced vasorelaxant effects that did not depend on the integrity of vascular endothelium. NPeth had a lesser vasorelaxant efficacy than NPprop and only the NPprop effects were inhibited by pretreatment with the sGC inhibitors, 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one (ODQ) or methylene blue. In an ODQ-preventable manner, NPprop inhibited the contractile component of the phenylephrine-induced response mediated by intracellular Ca 2+ release or by extracellular Ca 2+ recruitment through receptor- or voltage-operated Ca 2+ channels. In contrast, NPprop was inert against the transient contraction induced by caffeine in Ca 2+ -free medium. In an ODQ-dependent manner, NPprop inhibited the contraction induced by the protein kinase C activator phorbol 12,13-dibutyrate or by the tyrosine phosphatase inhibitor sodium orthovanadate. In silico docking analysis of a sGC homologous protein revealed preferential site for NPprop. In conclusion, the nitro compounds NPeth and NPprop induced vasorelaxation in rat aortic rings. Aliphatic chain substituents selectively interfered in the ability of these compounds to induce vasorelaxant effects, and only NPprop relaxed aortic rings via a sGC pathway. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Reduced estradiol-induced vasodilation and poly-(ADP-ribose polymerase (PARP activity in the aortas of rats with experimental polycystic ovary syndrome (PCOS.

    Directory of Open Access Journals (Sweden)

    Gabriella Masszi

    Full Text Available Polycystic ovary syndrome (PCOS is a complex endocrine disorder characterized by hyperandrogenism and insulin resistance, both of which have been connected to atherosclerosis. Indeed, an increased risk of clinical manifestations of arterial vascular diseases has been described in PCOS. On the other hand endothelial dysfunction can be detected early on, before atherosclerosis develops. Thus we assumed that vascular dysfunction is also related directly to the hormonal imbalance rather than to its metabolic consequences. To detect early functional changes, we applied a novel rodent model of PCOS: rats were either sham operated or hyperandrogenism was achieved by implanting subcutaneous pellets of dihydrotestosterone (DHT. After ten weeks, myograph measurements were performed on isolated aortic rings. Previously we described an increased contractility to norepinephrine (NE. Here we found a reduced immediate relaxation to estradiol treatment in pre-contracted aortic rings from hyperandrogenic rats. Although the administration of vitamin D3 along with DHT reduced responsiveness to NE, it did not restore relaxation to estradiol. Poly-(ADP-ribose polymerase (PARP activity was assessed by poly-ADP-ribose immunostaining. Increased PAR staining in ovaries and circulating leukocytes from DHT rats showed enhanced DNA damage, which was reduced by concomitant vitamin D3 treatment. Surprisingly, PAR staining was reduced in both the endothelium and vascular smooth muscle cells of the aorta rings from hyperandrogenic rats. Thus in the early phase of PCOS, vascular tone is already shifted towards vasoconstriction, characterized by reduced vasorelaxation and vascular dysfunction is concomitant with altered PARP activity. Based on our findings, PARP inhibitors might have a future perspective in restoring metabolic disorders in PCOS.

  9. Reduced estradiol-induced vasodilation and poly-(ADP-ribose) polymerase (PARP) activity in the aortas of rats with experimental polycystic ovary syndrome (PCOS).

    Science.gov (United States)

    Masszi, Gabriella; Horvath, Eszter Maria; Tarszabo, Robert; Benko, Rita; Novak, Agnes; Buday, Anna; Tokes, Anna-Maria; Nadasy, Gyorgy L; Hamar, Peter; Benyó, Zoltán; Varbiro, Szabolcs

    2013-01-01

    Polycystic ovary syndrome (PCOS) is a complex endocrine disorder characterized by hyperandrogenism and insulin resistance, both of which have been connected to atherosclerosis. Indeed, an increased risk of clinical manifestations of arterial vascular diseases has been described in PCOS. On the other hand endothelial dysfunction can be detected early on, before atherosclerosis develops. Thus we assumed that vascular dysfunction is also related directly to the hormonal imbalance rather than to its metabolic consequences. To detect early functional changes, we applied a novel rodent model of PCOS: rats were either sham operated or hyperandrogenism was achieved by implanting subcutaneous pellets of dihydrotestosterone (DHT). After ten weeks, myograph measurements were performed on isolated aortic rings. Previously we described an increased contractility to norepinephrine (NE). Here we found a reduced immediate relaxation to estradiol treatment in pre-contracted aortic rings from hyperandrogenic rats. Although the administration of vitamin D3 along with DHT reduced responsiveness to NE, it did not restore relaxation to estradiol. Poly-(ADP-ribose) polymerase (PARP) activity was assessed by poly-ADP-ribose immunostaining. Increased PAR staining in ovaries and circulating leukocytes from DHT rats showed enhanced DNA damage, which was reduced by concomitant vitamin D3 treatment. Surprisingly, PAR staining was reduced in both the endothelium and vascular smooth muscle cells of the aorta rings from hyperandrogenic rats. Thus in the early phase of PCOS, vascular tone is already shifted towards vasoconstriction, characterized by reduced vasorelaxation and vascular dysfunction is concomitant with altered PARP activity. Based on our findings, PARP inhibitors might have a future perspective in restoring metabolic disorders in PCOS.

  10. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. AORTA: Adding Organizational Reasoning to Agents

    DEFF Research Database (Denmark)

    Jensen, Andreas Schmidt; Dignum, Virginia

    2014-01-01

    the expected behavior of the agents. Agents need to be able to reason about the regulations, so that they can act within the expected boundaries and work towards the objectives of the organization. This extended abstract introduces AORTA, a component that can be integrated into agents’ reasoning mechanism......, allowing them to reason about (and act upon) regulations specified by an organizational model using simple reasoning rules. The added value is that the organizational model is independent of that of the agents, and that the approach is not tied to a specific organizational model....

  12. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  13. Microsurgical Bypass Training Rat Model, Part 1: Technical Nuances of Exposure of the Aorta and Iliac Arteries.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Lawton, Michael T; Mokhtari, Pooneh; Yousef, Sonia; Gandhi, Sirin; Benet, Arnau

    2017-11-01

    Animal models using rodents are frequently used for practicing microvascular anastomosis-an essential technique in cerebrovascular surgery. However, safely and efficiently exposing rat's target vessels is technically difficult. Such difficulty may lead to excessive hemorrhage and shorten animal survival. This limits the ability to perform multiple anastomoses on a single animal and may increase the overall training time and costs. We report our model for microsurgical bypass training in rodents in 2 consecutive articles. In part 1, we describe the technical nuances for a safe and efficient exposure of the rat abdominal aorta and common iliac arteries (CIAs) for bypass. Over a 2-year period, 50 Sprague-Dawley rats underwent inhalant anesthesia for practicing microvascular anastomosis on the abdominal aorta and CIAs. Lessons learned regarding the technical nuances of vessel exposure were recorded. Several technical nuances were important for avoiding intraoperative bleeding and preventing animal demise while preparing an adequate length of vessels for bypass. The most relevant technical nuances include (1) generous subcutaneous dissection; (2) use of cotton swabs for the blunt dissection of the retroperitoneal fat; (3) combination of sharp and blunt dissection to isolate the aorta and iliac arteries from the accompanying veins; (4) proper control of the posterior branches of the aorta; and (5) efficient division and mobilization of the left renal pedicle. Applying the aforementioned technical nuances enables safe and efficient preparation of the rat abdominal aorta and CIAs for microvascular anastomosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Storage Rings

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10 -6 eV to 3.5 x 10 12 eV (LHC, 7 x 10 12 eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams

  15. MR imaging of the toracic aorta

    International Nuclear Information System (INIS)

    Garbagnati, F.; Castoldi, M.C.; Bianchini, E.

    1988-01-01

    Various pathological conditions of the thoracic aorta were studied by MR Imaging in 31 patients: 23 were aneurysms (branching and non-branching), 2 artero-venous fistulae, 2 aortic prostheses, 2 Marfan's syndromes, 1 coronary sinus aneurysm, and 1 isthmic stenosis. MRI studies were always performed on patients who had been examined by other imaging procedures. A comparative study was carried out on the results of MRI, angiography, computerized tomography, and ultrasounds. The possibility of propedeutic protocol was explored. Our experience, in accordance with the literature on the subject, indicates MRI as the procedure of choice in the study of aneurysms of the toracic aorta. The advantages offered by MRI-the high natural contrast between circulating blood and the supporting structures, the possibility of obtaining multiplanar images as well as data on intraluminal, parietal, and extraparietal conditions-make it a highly competitive procedure if compared to either CT or angiography. While awaiting further evidence, the use of a propedeutic protocol in non-aneurysmatic diseases is still not advisable, due to insufficient patient population, and to the lack of a consistent literature on the subject

  16. Isolation of a Bis-Iodurated Tetra-THF as a Trace Product from the Oxidation of Squalene with RuO4 and Its Double Ring Expansion to a Novel bis-THF-bis-THP Compound

    Directory of Open Access Journals (Sweden)

    Nicola Borbone

    2011-06-01

    Full Text Available A novel bis-iodurated polyether compound, based on an unprecedented tetra-THF backbone, has been isolated as a trace by-product of the oxidation of squalene with the catalytic system RuO2(cat./NaIO4. The double erythro configuration of the central portion of the molecule furnishes the first indirect support of the previously postulated pathway operating in the oxidative pentacyclization of the isoprenoid substrate. A bidirectional double oxidative bis-cyclization is invoked to explain the formation of this compound. The isolated substance was successfully subjected to a double rearrangement-ring expansion to give a novel bis-THF-bis-THP compound.

  17. Topological rings

    CERN Document Server

    Warner, S

    1993-01-01

    This text brings the reader to the frontiers of current research in topological rings. The exercises illustrate many results and theorems while a comprehensive bibliography is also included. The book is aimed at those readers acquainted with some very basic point-set topology and algebra, as normally presented in semester courses at the beginning graduate level or even at the advanced undergraduate level. Familiarity with Hausdorff, metric, compact and locally compact spaces and basic properties of continuous functions, also with groups, rings, fields, vector spaces and modules, and with Zorn''s Lemma, is also expected.

  18. Ring accelerators

    International Nuclear Information System (INIS)

    Gisler, G.; Faehl, R.

    1983-01-01

    We present two-dimensional simulations in (r-z) and r-theta) cylinderical geometries of imploding-liner-driven accelerators of rings of charged particles. We address issues of azimuthal and longitudinal stability of the rings. We discuss self-trapping designs in which beam injection and extraction is aided by means of external cusp fields. Our simulations are done with the 2-1/2-D particle-in-cell plasma simulation code CLINER, which combines collisionless, electromagnetic PIC capabilities with a quasi-MHD finite element package

  19. Ring interferometry

    CERN Document Server

    Malykin, Grigorii B; Zhurov, Alexei

    2013-01-01

    This monograph is devoted to the creation of a comprehensive formalism for quantitative description of polarized modes' linear interaction in modern single-mode optic fibers. The theory of random connections between polarized modes, developed in the monograph, allows calculations of the zero shift deviations for a fiber ring interferometer. The monograph addresses also the

  20. The sequencing of the complete genome of a Tomato black ring virus (TBRV) and of the RNA2 of three Grapevine chrome mosaic virus (GCMV) isolates from grapevine reveals the possible recombinant origin of GCMV.

    Science.gov (United States)

    Digiaro, M; Yahyaoui, E; Martelli, G P; Elbeaino, T

    2015-02-01

    The complete genome of a Tomato black ring virus isolate (TBRV-Mirs) (RNA1, 7,366 nt and RNA2, 4,640 nt) and the RNA2 sequences (4,437; 4,445; and 4,442 nts) of three Grapevine chrome mosaic virus isolates (GCMV-H6, -H15, and -H27) were determined. All RNAs contained a single open reading frame encoding polyproteins of 254 kDa (p1) and 149 kDa (p2) for TBRV-Mirs RNA1 and RNA2, respectively, and 146 kDa for GCMV RNA2. p1 of TBRV-Mirs showed the highest identity with TBRV-MJ (94 %), Beet ringspot virus (BRSV, 82 %), and Grapevine Anatolian ringspot virus (GARSV, 66 %), while p2 showed the highest identity with TBRV isolates MJ (89 %) and ED (85 %), followed by BRSV (65 %), GCMV (58 %), and GARSV (57 %). The amino acid identity of RNA2 sequences of four GCMV isolates (three from this study and one from GenBank) ranged from 91 to 98 %, the homing protein being the most variable. The RDP3 program predicted putative intra-species recombination events for GCMV-H6 and recognized GCMV as a putative inter-species recombinant between GARSV and TBRV. In both cases, the recombination events were at the movement protein level.

  1. Can Severe Kyphoscoliosis Lead to Aorta Rupture?

    Science.gov (United States)

    Kotopoulos, Constantinos; Karakasi, Maria Valeria; Kapetanakis, Stylianos; Pavlidis, Pavlos

    2016-09-01

    Neurofibromatosis type 1 is a polysystemic disease presenting with a multifaceted clinical picture. Clinical manifestations may present in the skin, as well as in the skeletal and cardiovascular system. The present study aims to describe and examine the case of a 46-year-old woman, who suffered from neurofibromatosis type 1 and died abruptly in the emergency room. The forensic examination attributed her death to traumatic rupture of the thoracic aorta resulting from an acute angulation that her vertebral column formed in the thoracic region (severe kyphosis). Outspread cutaneous neurofibromas, severe scoliosis, and osteoporosis (brittle bones) were observed during the autopsy. No atherosclerotic lesions were detected in the aortic lumen. To the authors' knowledge, no similar case has been reported throughout relevant literature.

  2. Evaluation of diseases of the aorta with ultrafast CT

    International Nuclear Information System (INIS)

    Eldredge, W.J.; Flicker, S.; Altin, R.S.; Naidech, H.J.

    1987-01-01

    Ultrafast CT offers several advantages over standard CT for imaging of various congenital and acquired diseases of the aorta. Scan acquisition rates of 50 msec permit evaluation of the entire aorta following a single peripheral intravenous injection of iodinated contrast medium. Pathologic aortic flow patterns may also be defined using an ECG triggered ''flow'' mode, adding another dimension to CT evaluation of the aorta. The papers shows examples of a variety of aortic diseases, including coarctation, Marfan syndrome, atherosclerotic aneurysm, dissection, and postoperative abnormalities. The advantages of the modality are stressed

  3. Anomalous Posterior Intercostal Arterial Trunk Arising From the Abdominal Aorta

    Energy Technology Data Exchange (ETDEWEB)

    Jie, Bing, E-mail: jbshh@163.com; Yu, Dong, E-mail: yudong-mail@126.com; Jiang, Sen, E-mail: jasfly77@vip.163.com [Tongji University School of Medicine, Department of Radiology, Shanghai Pulmonary Hospital (China)

    2016-04-15

    A common trunk of the ipsilateral posterior intercostal artery (PIA) arising from the thoracic aorta is usually an anatomical variation. However, a common trunk of bilateral posterior intercostal arterial trunk (PIAT) arising from the abdominal aorta is rare. It is important to recognize this anatomical variation of PIA when performing interventional radiological procedures. We present a rare case of an anomalous PIAT that originated from the abdominal aorta in a patient with hemoptysis caused by tuberculosis sequelae. Bilateral 4th to 11th PIAs arose from a common trunk and the trunk arising from the posterior aspect of the abdominal aorta at the level of T12/L1 intervertebral space. The pathological right 4th and 5th PIAs and bronchial arteries were embolized. Hemoptysis has been controlled for 3 months.

  4. Obstructive pneumonia: an indication for surgery in mega aorta syndrome.

    Science.gov (United States)

    Kalkat, Maninder S; Bonser, Robert S

    2003-04-01

    A 76-year-old woman with annuloaortic ectasia, aortic regurgitation, and aneurysmal dilatation extending from the root to mid descending aorta presented with symptoms of bronchial compression and obstructive pneumonitis. Despite vigorous antibiotic treatment and physiotherapy, the pneumonitis persisted with clinical and radiologic deterioration. An emergency operation was performed to relieve bronchial compression. The operation comprised homograft aortic root replacement with prosthetic replacement of the arch and descending aorta. Postoperatively the pneumonia rapidly resolved.

  5. Surgical treatment of penetrating atherosclerotic ulcer of the descending aorta

    Directory of Open Access Journals (Sweden)

    Kovačević Pavle

    2013-01-01

    Full Text Available Introduction. The term “penetrating atherosclerotic ulcer” (PAU of the aorta describes the condition in which ulceration of an aortic atherosclerotic lesion penetrates the internal elastic lamina into media. PAU is a high-risk lesion due to its deleterious effects on the integrity of aortic wall, with potentially fatal outcome. Case report. A patient with intensive, sharp chest pain irradiating to the back but with no signs of myocardial ischemia on an electrocardiogram was referred to our hospital. Transthoracic echocardiography showed no pathological changes of the ascending aorta. However, multislice computed tomography (CT showed an aortic ulcer with varying degree of the subadventitial hemorrhage in the region of the thoracic aorta at the level of Th 8-9. Due to imminent rupture of the penetrating aortic ulcer, the patient was promptly prepared for surgery. A 15 cm long subadventitial hematoma was found intraoperatively in the right posterolateral aspect of the descending aorta, 5 cm above the diaphragm and 7 cm below the origin of the left subclavial artery. The affected segment of the aorta was resected, followed by an inlay aortic reconstruction with a Dacron tube graft of 24 mm. Control CT revealed satisfactory reconstruction of the descending aorta. Conclusion. PAU is a rare, but potentially fatal disease. Open surgery in patients with PAU is an effective treatment strategy, although endovascular treatment options are emerging.

  6. 6-Gingerol alleviates exaggerated vasoconstriction in diabetic rat aorta through direct vasodilation and nitric oxide generation

    Directory of Open Access Journals (Sweden)

    Ghareib SA

    2015-11-01

    Full Text Available Salah A Ghareib,1 Hany M El-Bassossy,1,2 Ahmed A Elberry,3,4 Ahmad Azhar,5 Malcolm L Watson,6 Zainy Mohammed Banjar7 1Department of Pharmacology and Toxicology, Faculty of Pharmacy, King Abdulaziz University, Jeddah, Saudi Arabia; 2Department of Pharmacology, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt; 3Department of Clinical Pharmacy, Faculty of Pharmacy, King Abdulaziz University, Jeddah, Saudi Arabia; 4Department of Pharmacology, Faculty of Medicine, Beni Suef University, Beni Suef, Egypt; 5Department of Pediatric Cardiology, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia; 6Department of Pharmacy and Pharmacology, University of Bath, Bath, UK; 7Department of Clinical Biochemistry, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia Abstract: The aim of the present study is to investigate the effect and potential mechanism of action of 6-gingerol on alterations of vascular reactivity in the isolated aorta from diabetic rats. Male Wistar rats were divided into two experimental groups, control and diabetics. Diabetes was induced by a single intraperitoneal injection of streptozotocin (50 mg kg-1, and the rats were left for 10 weeks to develop vascular complications. The effect of in vitro incubation with 6-gingerol (0.3–3 µM on the vasoconstrictor response of the isolated diabetic aortae to phenylephrine and the vasodilator response to acetylcholine was examined. Effect of 6-gingerol was also examined on aortae incubated with methylglyoxal as an advanced glycation end product (AGE. To investigate the mechanism of action of 6-gingerol, the nitric oxide synthase inhibitor Nω-nitro-L-arginine methyl ester hydrochloride (100 µM, guanylate cyclase inhibitor methylene blue (5 µM, calcium-activated potassium channel blocker tetraethylammonium chloride (10 mM, and cyclooxygenase inhibitor indomethacin (5 µM were added 30 minutes before assessing the direct vasorelaxant effect of 6

  7. Chronic lead exposure decreases the vascular reactivity of rat aortas: the role of hydrogen peroxide.

    Directory of Open Access Journals (Sweden)

    Karolini Zuqui Nunes

    Full Text Available We investigated whether exposure to small concentrations of lead alters blood pressure and vascular reactivity. Male Wistar rats were sorted randomly into the following two groups: control (Ct and treatment with 100 ppm of lead (Pb, which was added to drinking water, for 30 days. Systolic blood pressure (BP was measured weekly. Following treatment, aortic ring vascular reactivity was assessed. Tissue samples were properly stored for further biochemical investigation. The lead concentration in the blood reached approximately 8 μg/dL. Treatment increased blood pressure and decreased the contractile responses of the aortic rings to phenylephrine (1 nM-100 mM. Following N-nitro-L arginine methyl ester (L-NAME administration, contractile responses increased in both groups but did not differ significantly between them. Lead effects on Rmax were decreased compared to control subjects following superoxide dismutase (SOD administration. Catalase, diethyldithiocarbamic acid (DETCA, and apocynin increased the vasoconstrictor response induced by phenylephrine in the aortas of lead-treated rats but did not increase the vasoconstrictor response in the aortas of untreated rats. Tetraethylammonium (TEA potentiated the vasoconstrictor response induced by phenylephrine in aortic segments in both groups, but these effects were greater in lead-treated rats. The co-incubation of TEA and catalase abolished the vasodilatory effect noted in the lead group. The present study is the first to demonstrate that blood lead concentrations well below the values established by international legislation increased blood pressure and decreased phenylephrine-induced vascular reactivity. The latter effect was associated with oxidative stress, specifically oxidative stress induced via increases in hydrogen peroxide levels and the subsequent effects of hydrogen peroxide on potassium channels.

  8. Investigation of pulsatile flowfield in healthy thoracic aorta models.

    Science.gov (United States)

    Wen, Chih-Yung; Yang, An-Shik; Tseng, Li-Yu; Chai, Jyh-Wen

    2010-02-01

    Cardiovascular disease is the primary cause of morbidity and mortality in the western world. Complex hemodynamics plays a critical role in the development of aortic dissection and atherosclerosis, as well as many other diseases. Since fundamental fluid mechanics are important for the understanding of the blood flow in the cardiovascular circulatory system of the human body aspects, a joint experimental and numerical study was conducted in this study to determine the distributions of wall shear stress and pressure and oscillatory WSS index, and to examine their correlation with the aortic disorders, especially dissection. Experimentally, the Phase-Contrast Magnetic Resonance Imaging (PC-MRI) method was used to acquire the true geometry of a normal human thoracic aorta, which was readily converted into a transparent thoracic aorta model by the rapid prototyping (RP) technique. The thoracic aorta model was then used in the in vitro experiments and computations. Simulations were performed using the computational fluid dynamic (CFD) code ACE+((R)) to determine flow characteristics of the three-dimensional, pulsatile, incompressible, and Newtonian fluid in the thoracic aorta model. The unsteady boundary conditions at the inlet and the outlet of the aortic flow were specified from the measured flowrate and pressure results during in vitro experiments. For the code validation, the predicted axial velocity reasonably agrees with the PC-MRI experimental data in the oblique sagittal plane of the thoracic aorta model. The thorough analyses of the thoracic aorta flow, WSSs, WSS index (OSI), and wall pressures are presented. The predicted locations of the maxima of WSS and the wall pressure can be then correlated with that of the thoracic aorta dissection, and thereby may lead to a useful biological significance. The numerical results also suggest that the effects of low WSS and high OSI tend to cause wall thickening occurred along the inferior wall of the aortic arch and the

  9. Kayser-Fleischer Rings

    Science.gov (United States)

    ... Support Contacts Lab Tracker/Copper Calculator Stories Programs & Research ... About Everything you need to know about Wilson Disease Kayser-Fleischer Rings Definition Kayser-Fleischer Ring: Clinical sign. Brownish-yellow ring visible around the corneo- ...

  10. ASSOCIATIVE RINGS SOLVED AS LIE RINGS

    Directory of Open Access Journals (Sweden)

    M. B. Smirnov

    2011-01-01

    Full Text Available The paper has proved that an associative ring which is solvable of a n- class as a Lie ring has a nilpotent ideal of the nilpotent class not more than 3×10n–2  and a corresponding quotient ring satisfies an identity [[x1, x2, [x3, x4

  11. Spiral blood flow in aorta-renal bifurcation models.

    Science.gov (United States)

    Javadzadegan, Ashkan; Simmons, Anne; Barber, Tracie

    2016-01-01

    The presence of a spiral arterial blood flow pattern in humans has been widely accepted. It is believed that this spiral component of the blood flow alters arterial haemodynamics in both positive and negative ways. The purpose of this study was to determine the effect of spiral flow on haemodynamic changes in aorta-renal bifurcations. In this regard, a computational fluid dynamics analysis of pulsatile blood flow was performed in two idealised models of aorta-renal bifurcations with and without flow diverter. The results show that the spirality effect causes a substantial variation in blood velocity distribution, while causing only slight changes in fluid shear stress patterns. The dominant observed effect of spiral flow is on turbulent kinetic energy and flow recirculation zones. As spiral flow intensity increases, the rate of turbulent kinetic energy production decreases, reducing the region of potential damage to red blood cells and endothelial cells. Furthermore, the recirculation zones which form on the cranial sides of the aorta and renal artery shrink in size in the presence of spirality effect; this may lower the rate of atherosclerosis development and progression in the aorta-renal bifurcation. These results indicate that the spiral nature of blood flow has atheroprotective effects in renal arteries and should be taken into consideration in analyses of the aorta and renal arteries.

  12. The problem of calcified ascending aorta during aortocoronary bypass

    Directory of Open Access Journals (Sweden)

    Nežić Duško G.

    2004-01-01

    Full Text Available Heavily calcified ascending aorta significantly increased morbidity and lethality during open-heart surgery. Cannulation and clamping (partial or total of severely atherosclerotic ascending aorta can easily cause damage and rupture of aortic wall, with consequential distal (often fatal embolization with atheromatous debris (brain, myocardium. From June 1998. until June 2000, 11 of 2 136 (0.5% patients who underwent coronary artery bypass grafting were with the severe atheromatous ascending aorta. The site of cannulation was in the aortic arch in three patients (aorta was occluded with Foley catheter in one case, and single clamp technique was used in the other two cases. The femoral artery was the cannulation site in other five cases. Profound hypothermia, ventricular fibrillation, and circulatory arrest, with no cross-clamping or cardioplegia, were used in three patients. Two patients were operated on with extracorporeal circulation, one in normothermia, on the beating heart, the other in moderate hypothermia, on fibrillating heart. In three patients myocardial revascularization was performed on the beating heart, in normothermia, without extracorporeal circulation. Postoperative course was uneventful in all 11 patients. Neither atheroembolism in the peripheral organs, nor atheroembolism of the extramities occurred. The proposed surgical approaches have the potential to reduce the prevalence of stroke and systemic embolization associated with coronary artery bypass grafting in patients with heavily calcified ascending aorta. This result was achieved due to the applied modifications of standard cardiosurgical technique.

  13. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  14. Direct emergence of the dorsospinal artery from the aorta and spinal cord blood supply. Case reports and literature review

    International Nuclear Information System (INIS)

    Siclari, Francesca; Fasel, Jean H.D.; Gailloud, Philippe

    2006-01-01

    Direct emergence of a dorsospinal artery from the aorta is a rare anatomic variant, of which a total of seven cases have been reported. This report offers an additional angiographic observation and reviews the literature. Two observations of common intercostal trunks documented during spinal angiography are described. In the first observation, the common intercostal trunk provided complete blood supply to two adjacent vertebral levels (T11 and T12). In other words, the trunk included an intercostal branch and a dorsospinal branch for each level. In the second observation, the common intercostal trunk provided an intercostal branch for each level (T9 and T10), but only one dorsospinal branch (T10). An isolated dorsospinal artery (DA) originated separately from the aorta at the T9 level, and provided a significant contribution to the anterior spinal axis. The two reported cases illustrate the concept of ''complete'' versus ''incomplete'' common intercostal trunks. In instances where an incomplete trunk is documented, a separate DA originating directly from the aorta must be looked for. A review of the literature indicates a tendency for isolated DAs to participate in the blood supply to the spinal cord. (orig.)

  15. Polymer nanocomposites enhance S-nitrosoglutathione intestinal absorption and promote the formation of releasable nitric oxide stores in rat aorta.

    Science.gov (United States)

    Wu, Wen; Perrin-Sarrado, Caroline; Ming, Hui; Lartaud, Isabelle; Maincent, Philippe; Hu, Xian-Ming; Sapin-Minet, Anne; Gaucher, Caroline

    2016-10-01

    Alginate/chitosan nanocomposite particles (GSNO-acNCPs), i.e. S-nitrosoglutathione (GSNO) loaded polymeric nanoparticles incorporated into an alginate and chitosan matrix, were developed to increase the effective GSNO loading capacity, a nitric oxide (NO) donor, and to sustain its release from the intestine following oral administration. Compared with free GSNO and GSNO loaded nanoparticles, GSNO-acNCPs promoted 2.7-fold GSNO permeation through a model of intestinal barrier (Caco-2 cells). After oral administration to Wistar rats, GSNO-acNCPs promoted NO storage into the aorta during at least 17h, as highlighted by (i) a long-lasting hyporeactivity to phenylephrine (decrease in maximum vasoconstrictive effect of aortic rings) and (ii) N-acetylcysteine (a thiol which can displace NO from tissues)-induced vasodilation of aorxxtic rings preconstricted with phenylephrine. In conclusion, GSNO-acNCPs enhance GSNO intestinal absorption and promote the formation of releasable NO stores into the rat aorta. GSNO-acNCPs are promising carriers for chronic oral application devoted to the treatment of cardiovascular diseases. Copyright © 2016. Published by Elsevier Inc.

  16. The coral reef aorta - a single centre experience in 70 patients.

    Science.gov (United States)

    Grotemeyer, Dirk; Pourhassan, Siamak; Rehbein, Hermann; Voiculescu, Adina; Reinecke, Petra; Sandmann, Wilhelm

    2007-01-01

    Coral reef aorta (CRA) is described as rock-hard calcifications in the visceral part of the aorta. These heavily calcified plaques grow into the lumen and can cause significant stenoses, which may lead to malperfusion of the lower limbs, visceral ischemia or hypertension due to renal ischemia. From January 1984 to February 2007, 70 patients (24 men, 46 women, mean age 59.5 years, range 14 to 81 years) underwent treatment in the Department of Vascular Surgery and Renal Transplantation, University Hospital, Heinrich-Heine-University (Düsseldorf, Germany) for CRA. The present study is based on a review of patients' records and the prospective follow-up in the outpatient clinic. The most frequent finding was renovascular arterial hypertension (44.3%) causing headache, vertigo and visual symptoms. Intermittent claudication due to peripheral arterial occlusive disease was found in 28 patients (40.0%). Seventeen patients (24.3%) presented with chronic visceral ischemia causing diarrhea, weight loss and abdominal pain. Sixty-nine of the 70 patients (98.6%) underwent surgery; in 57 patients, aortic reconstruction was achieved with thromboendarterectomy, performed on an isolated suprarenal segment in six cases (8.7%), an infrarenal segment in 15 cases (21.7%), and the supra- and infrarenal aorta in 43 cases (62.3%). Eight patients (11.6%) died during or soon after surgery. Postoperative complications requiring corrective surgery occurred in 11 patients (15.9%). Almost one-third of the patients (n=19, 27.5%) returned for follow-up after a mean of 52.6 months (range six to 215 months). Of the 19 patients, there was significant clinical and diagnostic improvement in 16 patients (84.2%) and three patients (15.8%) were unchanged. Impairment was not observed. Despite the existing and improving surgical techniques for the treatment of CRA, its pathophysiological basis and genesis is not yet understood.

  17. 1,4-Anhydro-4-seleno-d-talitol (SeTal) protects endothelial function in the mouse aorta by scavenging superoxide radicals under conditions of acute oxidative stress

    DEFF Research Database (Denmark)

    Ng, Hooi Hooi; Leo, Chen Huei; O'Sullivan, Kelly

    2017-01-01

    and decreased basal nitric oxide (NO) availability. SeTal (1mM) co-treatment prevented high glucose-induced endothelial dysfunction and oxidative stress in the mouse aorta. The presence of a cyclooxygenase inhibitor, indomethacin significantly improved the sensitivity to ACh in high glucose-treated aortae......, but had no effect in SeTal-treated aortae. Our data show that SeTal has potent antioxidant activity in isolated mouse aortae and prevents high glucose-induced endothelial dysfunction by decreasing superoxide levels, increasing basal NO availability and normalising the contribution of vasoconstrictor......Hyperglycaemia increases the generation of reactive oxidants in blood vessels and is a major cause of endothelial dysfunction. A water-soluble selenium-containing sugar (1,4-Anhydro-4-seleno-d-talitol, SeTal) has potent antioxidant activity in vitro and is a promising treatment to accelerate wound...

  18. Surgery for pseudoaneurysm of the ascending aorta under moderate hypothermia

    Directory of Open Access Journals (Sweden)

    Lee Dong-Hyup

    2011-09-01

    Full Text Available Abstract Pseudoaneurysm of the ascending aorta is a rare complication after cardiac surgery. Particularly, pseudoaneurysm due to postoperative infection in the ascending aorta requires surgical treatment with antibiotics. If a large sized pseudoaneurysm is located at the retrosternal space, then there is a very high risk of massive bleeding from rupture during performance of resternotomy. To avoid this risk, we performed femoro-femoral bypass under moderate hypothermia with transient circulatory arrest, and we report here on the successful result of this case.

  19. Gadolinium-enhanced MR angiography of the thoracoabdominal aorta diseases

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Wolosker, Nelson; Galvao Filho, Mario; Kalil, Jorge A.; Wolosker, Angela; Borri, Maria Lucia

    1998-01-01

    Gadolinium-enhanced MR angiography (GEMRA) of the thoracoabdominal aorta is a noninvasive technique that can rapidly delineate the branch vessels diseases, without flow or respiration artifacts, obtained with non contrast MRA. The objective of this paper is to show the main clinical applications of GEMRA, compared to non contrast sequences. We have evaluated 30 patients with thorocoabdominal aorta diseases. These patients have been examined with GEMRA (3D, FFE sequences) obtained after 30 mlIV contrast injection and non contrast MRA (2D-TOF sequences). In our experience, gadolinium-enhanced MRA is a high resolution and speedy technique with advantages over non contrast MRA. (author)

  20. Stirling engine piston ring

    Science.gov (United States)

    Howarth, Roy B.

    1983-01-01

    A piston ring design for a Stirling engine wherein the contact pressure between the piston and the cylinder is maintained at a uniform level, independent of engine conditions through a balancing of the pressure exerted upon the ring's surface and thereby allowing the contact pressure on the ring to be predetermined through the use of a preloaded expander ring.

  1. Alternative loop rings

    CERN Document Server

    Goodaire, EG; Polcino Milies, C

    1996-01-01

    For the past ten years, alternative loop rings have intrigued mathematicians from a wide cross-section of modern algebra. As a consequence, the theory of alternative loop rings has grown tremendously. One of the main developments is the complete characterization of loops which have an alternative but not associative, loop ring. Furthermore, there is a very close relationship between the algebraic structures of loop rings and of group rings over 2-groups. Another major topic of research is the study of the unit loop of the integral loop ring. Here the interaction between loop rings and group ri

  2. [Coarctation of the descending aorta. A rare form of connatal aortic stenosis].

    Science.gov (United States)

    Stammwitz, E; Schöttler, M; Brix, F; Poser, H L; Langkau, G; Yükseltan, I

    1983-07-01

    A clinical diagnosis of a coarctation of the aorta was made in a 17-year-old female hypertensive patient. Angiography revealed an atypical stenosis of the descending aorta which was surgically corrected. The causes of aortic stenoses are discussed.

  3. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Science.gov (United States)

    Barik, Ramachandra; Patnaik, Amar Narayana; Kumar, Ravintula Venkata; Mohapatra, Rudra Prasad; Medep, Vikas; Nemani, Lalita

    2014-01-01

    Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA). PMID:24987261

  4. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Energy Technology Data Exchange (ETDEWEB)

    Barik, Ramachandra; Patnaik, Amar Narayana [Department of Cardiology, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India); Kumar, Ravintula Venkata; Mohapatra, Rudra Prasad [Department of Cardiothoracic Surgery, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India); Medep, Vikas; Nemani, Lalita [Department of Cardiology, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India)

    2014-01-01

    Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA)

  5. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Directory of Open Access Journals (Sweden)

    Ramachandra Barik

    2014-01-01

    Full Text Available Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA.

  6. Hypergravity and multiple reflections in wave propagation in the aorta

    NARCIS (Netherlands)

    Kroot, J.M.B.; Giannopapa, C.G.

    2013-01-01

    Hypergravity and gravity changes encountered in, e.g., airplanes, rollercoasters, and spaceflight can result in headaches or loss of consciousness due to decreased cerebral blood flow. This paper describes the effect of hypergravity and gravity changes on the pressure in the aorta and the distension

  7. The AORTA Architecture: Integrating Organizational Reasoning in Jason

    DEFF Research Database (Denmark)

    Jensen, Andreas Schmidt; Dignum, Virginia; Villadsen, Jørgen

    2014-01-01

    the expected behavior of the agents. Agents need to be able to reason about the regulations, so that they can act within the expected boundaries and work towards the objectives of the organization. In this paper, we describe the AORTA (Adding Organizational Reasoning to Agents) architecture for making agents...

  8. Coil embolization of an anastomotic leak after ascending aorta replacement

    DEFF Research Database (Denmark)

    Nørgaard, Anders; Andersen, Lars Ib; Haahr, P.E.

    2008-01-01

    treated aneurysm in the ascending thoracic aorta complicated with an anastomotic leak. If a short prosthesis (6 cm) had been available, the anastomotic leak would have been treated with endovascular repair. In lack of this prosthesis, we were forced to treat the patient with a method not generally...

  9. Insulin resistance, its association with diastolic left ventricular disease and aorta elasticity in hypertensive patients

    Directory of Open Access Journals (Sweden)

    E.I. Shorikov

    2017-04-01

    Full Text Available Background. The accepted threshold of insulin resistance value in arterial hypertension (AH is absent, thus it is relevant to determine its degree in patients with AH, and to determine the interaction between the insulin resistance (IR syndrome and the target organs injury. The purpose of our study was to set the threshold of IR in patients with AH, to define association between the IR parameters, presence of diastolic dysfunction and the state of aorta elasticity. Materials and methods. Investigation included 229 patients with AH and type 2 diabetes mellitus (DM, as well as 108 patients with the isolated AH. There were used clinical, instrumental, biochemical (HOMA-2 model, HOMA-IR indices, statistical methods. Results. The course of the isolated AH and AH with concomitant type 2 DM is associated with IR development, that it is well-proven in the model of HOMA-2 (р < 0.001. In patients with comorbid patho­logy the sensitiveness of peripheral tissues to insulin depends on severity of AH (р < 0.001. Presence of IR in HOMA-IR model was revealed in patients with the isolated AH in 26.6 % of cases. The level of plasma insulin grows substantially, and the tissues sensitiveness to insulin declined at the third type of diastolic dysfunction (р < 0.05. The coefficients of aorta elasticity have a reverse correlation with all parameters of НОМА-2 model determined by the levels of glucose (р < 0.001, insulin (p < 0.05, coefficient НОМА-IR (p < 0.05 and direct association with the degree of peri­pheral tissues sensitivity to insulin (p < 0.01. Conclusions. The threshold of IR by HOMA-2 model in patients was set at the level of 1.87; the increase of aorta inflexibility and diastolic dysfunction severity depend on IR severity.

  10. Impairment of the vascular relaxation and differential expression of caveolin-1 of the aorta of diabetic +db/+db mice.

    Science.gov (United States)

    Lam, Tze Yan; Seto, Sai Wang; Lau, Yee Man; Au, Lai Shan; Kwan, Yiu Wa; Ngai, Sai Ming; Tsui, Kwong Wing

    2006-09-28

    In this study, we compared the endothelium-dependent and -independent relaxation of the isolated thoracic aorta of control (+db/+m) and diabetic (+db/+db) (C57BL/KsJ) mice. The gene expression (mRNA and protein) level of the muscarinic M(3) receptors, endothelial nitric oxide synthase (eNOS) and caveolin-1 of the aorta was also evaluated. Acetylcholine caused a concentration-dependent, N(G)-nitro-L-arginine methyl-ester (20 microM)-sensitive relaxation, with approximately 100% relaxation at 10 microM, in +db/+m mice. In +db/+db mice, the acetylcholine-induced relaxation was significantly smaller (maximum relaxation: approximately 80%). The sodium nitroprusside-mediated relaxation was slightly diminished in +db/+db mice, compared to +db/+m mice. However, there was no significant difference in the isoprenaline- and cromakalim-induced relaxation observed in both species. The mRNA and protein expression levels of caveolin-1 were significantly higher in the aorta of +db/+db mice. In contrast, there was no difference in the mRNA and protein expression levels of eNOS and muscarinic M(3) receptors between these mice. Our results demonstrate that the impairment of the acetylcholine-induced, endothelium-dependent aortic relaxation observed in +db/+db mice was probably associated with an enhanced expression of caveolin-1 mRNA and protein.

  11. Inhibition of PKC-dependent extracellular Ca{sup 2+} entry contributes to the depression of contractile activity in long-term pressure-overloaded endothelium-denuded rat aortas

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, J.; López, R.M.; López, P.; Castillo, M.C.; Querejeta, E.; Ruiz, A.; Castillo, E.F. [Sección de Estudios de Posgrado e Investigación, Escuela Superior de Medicina, Instituto Politécnico Nacional, México, DF (Mexico)

    2014-08-01

    We examined the contractile responsiveness of rat thoracic aortas under pressure overload after long-term suprarenal abdominal aortic coarctation (lt-Srac). Endothelium-dependent angiotensin II (ANG II) type 2 receptor (AT{sub 2}R)-mediated depression of contractions to ANG II has been reported in short-term (1 week) pressure-overloaded rat aortas. Contractility was evaluated in the aortic rings of rats subjected to lt-Srac or sham surgery (Sham) for 8 weeks. ANG I and II levels and AT{sub 2}R protein expression in the aortas of lt-Srac and Sham rats were also evaluated. lt-Srac attenuated the contractions of ANG II and phenylephrine in the aortas in an endothelium-independent manner. However, lt-Srac did not influence the transient contractions induced in endothelium-denuded aortic rings by ANG II, phenylephrine, or caffeine in Ca{sup 2+}-free medium or the subsequent tonic constrictions induced by the addition of Ca{sup 2+} in the absence of agonists. Thus, the contractions induced by Ca{sup 2+} release from intracellular stores and Ca{sup 2+} influx through stored-operated channels were not inhibited in the aortas of lt-Srac rats. Potassium-elicited contractions in endothelium-denuded aortic rings of lt-Srac rats remained unaltered compared with control tissues. Consequently, the contractile depression observed in aortic tissues of lt-Srac rats cannot be explained by direct inhibition of voltage-operated Ca{sup 2+} channels. Interestingly, 12-O-tetradecanoylphorbol-13-acetate-induced contractions in endothelium-denuded aortic rings of lt-Srac rats were depressed in the presence but not in the absence of extracellular Ca{sup 2+}. Neither levels of angiotensins nor of AT{sub 2}R were modified in the aortas after lt-Srac. The results suggest that, in rat thoracic aortas, lt-Srac selectively inhibited protein kinase C-mediated activation of contraction that is dependent on extracellular Ca{sup 2+} entry.

  12. Rings in drugs.

    Science.gov (United States)

    Taylor, Richard D; MacCoss, Malcolm; Lawson, Alastair D G

    2014-07-24

    We have analyzed the rings, ring systems, and frameworks in drugs listed in the FDA Orange Book to understand the frequency, timelines, molecular property space, and the application of these rings in different therapeutic areas and target classes. This analysis shows that there are only 351 ring systems and 1197 frameworks in drugs that came onto the market before 2013. Furthermore, on average six new ring systems enter drug space each year and approximately 28% of new drugs contain a new ring system. Moreover, it is very unusual for a drug to contain more than one new ring system and the majority of the most frequently used ring systems (83%) were first used in drugs developed prior to 1983. These observations give insight into the chemical novelty of drugs and potentially efficient ways to assess compound libraries and develop compounds from hit identification to lead optimization and beyond.

  13. Birth Control Ring

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Ring KidsHealth / For Teens / Birth Control Ring What's ...

  14. Groups, rings, modules

    CERN Document Server

    Auslander, Maurice

    2014-01-01

    This classic monograph is geared toward advanced undergraduates and graduate students. The treatment presupposes some familiarity with sets, groups, rings, and vector spaces. The four-part approach begins with examinations of sets and maps, monoids and groups, categories, and rings. The second part explores unique factorization domains, general module theory, semisimple rings and modules, and Artinian rings. Part three's topics include localization and tensor products, principal ideal domains, and applications of fundamental theorem. The fourth and final part covers algebraic field extensions

  15. A "blind" vascular ring in association with congenital cystic adenomatoid malformation: A case report.

    Science.gov (United States)

    Xia, Bo; Hong, Chun; Tang, Jing; Liu, Cuifen; Yu, Gang

    2017-12-01

    The occurrence of congenital cystic adenomatoid malformation (CCAM) and vascular ring (VR) is extremely rare. We present a case of left CCAM with VR consisting of a left aortic arch and right descending aorta with left tracheal compression causing atelectasis. A high-risk male neonate with the diagnosis of left CCAM was diagnosed at 20 weeks gestational age by antenatal ultrasound. Chest CT revealed multiple cysts in the left inferior lung. Cardiac CT showed VR consisting of a left aortic arch and right descending aorta with left tracheal compression causing atelectasis. left inferior lobectomy was performed. Cardiac CT showed VR consisting of a left aortic arch and right descending aorta with left tracheal compression causing atelectasis. Descending aorta transposition was performed. The patient recovered smoothly and remained asymptomatic during the 12-months of postoperative follow-up period. We report this rare case of CCAM with VR consisting of left aortic arch and right descending aorta with left tracheal compression causing atelectasis. From the findings of this report, early surgical treatment is recommended. Although the prognosis after surgery remained good, second surgery can be avoided if VR was detected early. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  16. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    Science.gov (United States)

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Lipid synthesis in the aorta of chick and other species

    International Nuclear Information System (INIS)

    Rao, A.R.

    1976-01-01

    The relative rate of fatty acid biosynthesis from labelled acetate in the adipose tissue of chicken is much lower than that in the rat (O'Hea and Leveille, 1968). To determine similar species differences in lipid synthesis in the aortas of cock, rat, rabbit and monkey, thoracic and abdominal segments of fresh aortas were incubated in vitro with (1- 14 C)-acetate for 3 h. Total lipids and their fractions (free and total cholesterol, free fatty acids, triglycerides and phospholipids) were counted for radioactivity. Incorporation of radioactivity into total as well as all classes of lipids was several times greater in chicken than in other species. Significant and consistent incorporation into cholesterol occurred only in chicks. Synthesis into total lipids and triglycerides was greater in the thoracic segment of chicks. These findings (Rao and Rao, 1968) are consistent with the ready susceptibility of chicken to atherosclerosis. (author)

  18. Mechanics, Mechanobiology, and Modeling of Human Abdominal Aorta and Aneurysms

    Science.gov (United States)

    Humphrey, J.D.; Holzapfel, G.A.

    2011-01-01

    Biomechanical factors play fundamental roles in the natural history of abdominal aortic aneurysms (AAAs) and their responses to treatment. Advances during the past two decades have increased our understanding of the mechanics and biology of the human abdominal aorta and AAAs, yet there remains a pressing need for considerable new data and resulting patient-specific computational models that can better describe the current status of a lesion and better predict the evolution of lesion geometry, composition, and material properties and thereby improve interventional planning. In this paper, we briefly review data on the structure and function of the human abdominal aorta and aneurysmal wall, past models of the mechanics, and recent growth and remodeling models. We conclude by identifying open problems that we hope will motivate studies to improve our computational modeling and thus general understanding of AAAs. PMID:22189249

  19. MagnetoHemoDynamics in the aorta and electrocardiograms

    International Nuclear Information System (INIS)

    Martin, Vincent; Drochon, Agnès; Fokapu, Odette; Gerbeau, Jean-Frédéric

    2012-01-01

    This paper addresses a complex multi-physical phenomenon involving cardiac electrophysiology and hemodynamics. The purpose is to model and simulate a phenomenon that has been observed in magnetic resonance imaging machines: in the presence of a strong magnetic field, the T-wave of the electrocardiogram (ECG) gets bigger, which may perturb ECG-gated imaging. This is due to a magnetohydrodynamic (MHD) effect occurring in the aorta. We reproduce this experimental observation through computer simulations on a realistic anatomy, and with a three-compartment model: inductionless MHD equations in the aorta, bi-domain equations in the heart and electrical diffusion in the rest of the body. These compartments are strongly coupled and solved using finite elements. Several benchmark tests are proposed to assess the numerical solutions and the validity of some modeling assumptions. Then, ECGs are simulated for a wide range of magnetic field intensities (from 0 to 20 T). (paper)

  20. Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.

    Science.gov (United States)

    Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet

    2018-05-01

    This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Intrapericardial bronchogenic cyst adherent to ascending aorta in young patient

    Directory of Open Access Journals (Sweden)

    Reddy Atipo-Galloye

    2014-06-01

    Full Text Available Bronchogenic cysts arise from an abnormal budding of the ventral diverticulum of the foregut or the thracheobronchial tree during embryogenesis. An intrapericardial location is an extremely rare finding. Symptoms are related to cardiac structure compression, but in most case they remain asymptomatic. We present a case of intrapericardial bronchogenic cyst in a young patient, resected entirely with repair of right lateral proximal ascending aorta with PTFE graft.

  2. Descending thoracic aorta dissection associated with esophageal carcinoma

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available The association of aortic dissection with a malignancy is a rare finding and previous reports are usually those of primary aortic sarcomas. A 45-year-old male presented to us with chest pain and dysphagia for 1 month with a background history of obstructive airway disease and uncontrolled hypertension. In this report we present a case of typical descending aorta dissection with associated esophageal carcinoma.

  3. Noninvasive radiodiagnosis of aneurysms of the thoracic aorta

    International Nuclear Information System (INIS)

    Todua, F.I.; Petsko, A.P.; Arablinskij, A.V.; Kazanchyan, P.O.; Nikitaev, N.S.; Sultanaliev, T.A.

    1990-01-01

    The paper is concerned with analysis of the results of X-ray investigation of 45 patients with aneurysms of the distal part of the arch and descending part of the thoracic aorta. X-ray investigation helped to establish correct diagnosis of aneurysm of the aorta in 42 of 45 patients (93.3 %) on the basis of the detection of intense additional shadow formation in left pulmonary field, unseparable from the aortic shadow. The use of a new method of ultrasound diagnosis-duplex scanning-made it possible to establish the presence of aneurysm and to determine its sizes as well as to visualize the relation of the left subclavicular artery to aneurysm in 17 of 21 patients. CT-semiotics of aneurysms of the descending part of the thoracic aorta consisted in its dilatation over 3.5 cm, wall calcification, thrombosis of the cavity and change of the adjacent structures. Basing on the analysis of these signs correct diagnosis was established in 34 of 35 examinees (97.1 %)

  4. Hemodynamic Modeling of Surgically Repaired Coarctation of the Aorta.

    Science.gov (United States)

    Olivieri, Laura J; de Zélicourt, Diane A; Haggerty, Christopher M; Ratnayaka, Kanishka; Cross, Russell R; Yoganathan, Ajit P

    2011-12-01

    PURPOSE: Late morbidity of surgically repaired coarctation of the aorta includes early cardiovascular and cerebrovascular disease, shortened life expectancy, abnormal vasomodulator response, hypertension and exercise-induced hypertension in the absence of recurrent coarctation. Observational studies have linked patterns of arch remodeling (Gothic, Crenel, and Romanesque) to late morbidity, with Gothic arches having the highest incidence. We evaluated flow in native and surgically repaired aortic arches to correlate respective hemodynamic indices with incidence of late morbidity. METHODS: Three dimensional reconstructions of each remodeled arch were created from an anatomic stack of magnetic resonance (MR) images. A structured mesh core with a boundary layer was generated. Computational fluid dynamic (CFD) analysis was performed assuming peak flow conditions with a uniform velocity profile and unsteady turbulent flow. Wall shear stress (WSS), pressure and velocity data were extracted. RESULTS: The region of maximum WSS was located in the mid-transverse arch for the Crenel, Romanesque and Native arches. Peak WSS was located in the isthmus of the Gothic model. Variations in descending aorta flow patterns were also observed among the models. CONCLUSION: The location of peak WSS is a primary difference among the models tested, and may have clinical relevance. Specifically, the Gothic arch had a unique location of peak WSS with flow disorganization in the descending aorta. Our results suggest that varied patterns and locations of WSS resulting from abnormal arch remodeling may exhibit a primary effect on clinical vascular dysfunction.

  5. Differential identification of atypical pneumonia pathogens in aorta and internal mammary artery related to ankle brachial index and walking distance.

    Science.gov (United States)

    Iriz, Erkan; Cirak, Meltem Yalinay; Zor, Mustafa Hakan; Engin, Doruk; Oktar, Levent; Unal, Yusuf

    2013-08-01

    We studied the existence of agents in aorta biopsies, such as Chlamydia pneumoniae, cytomegalovirus, and Mycoplasma pneumoniae, that are thought to have a role in atherosclerosis etiopathogenesis role, and their association with peripheral artery disease. We examined aorta wall and internal mammarian artery (IMA) biopsies taken from two different places in 63 patients in whom coronary artery bypass was performed. In these biopsies, we evaluated the deoxyribonuclease (DNA) of these microorganisms using polymerase chain reaction. From the same patients, we recorded the ankle brachial index, road walking distance information, lipid profile, C-reactive proteins, blood parameters such as fibrinogen, and the patient's operation data. In the nine aorta biopsies taken from 63 patients, we isolated C pneumoniae DNA. In IMA biopsies taken from the same patients, we detected no microorganism DNA (P artery disease. In the development of atherosclerosis with C pneumoniae, there may be a determinant pathogen in both the aorta and the peripheral arteries. The nonexistence of C pneumoniae DNA in the IMA biopsies may indicate infectious agents because of the predominant endothelial functions in this artery, and thus its resistance to atherosclerosis. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. [Occlusive aortic disease as coral reef aorta--experience in 80 cases].

    Science.gov (United States)

    Sagban, A T; Grotemeyer, D; Rehbein, H; Sandmann, W; Duran, M; Balzer, K M; Grabitz, K

    2010-10-01

    Coral reef aorta (CRA) is described as rock-hard calcifications in the visceral part of the aorta. These heavily calcified plaques grow into the lumen and can cause significant stenoses, leading to malperfusion of the lower limbs, visceral ischaemia or hypertension due to renal ischaemia. From 1/1984 to 11/2008, 80 patients (26 m, 54 f, mean age 61.6, range 14 to 86 years) underwent treatment in the Department of Vascular Surgery and Kidney Transplantation, Heinrich-Heine-University Hospital for CRA. The present study is based on a review of patient records and prospective follow-up in our outpatient clinic. The most frequent finding was renovascular hypertension (n=33, 41.3%) causing headache, vertigo and visual symptoms. Intermittent claudication due to peripheral arterial occlusive disease was found in 35 cases (43.8%). 15 patients (18.8%) presented with chronic visceral ischaemia causing diarrhoea, weight loss and abdominal pain. 79 patients (98.7%) underwent surgery; in 73 (93.7%) aortic reconstruction was achieved with thromboendarterectomy, on an isolated suprarenal segment in 7 (9.3%), an infrarenal segment in 21 (26.6%), and the supra- and infrarenal aorta in 45 cases (60%). Desobliteration of renal arteries was performed in 47 (one-sided n=8, 10.1%; both arteries n=39, 49.4%); the aortic bifurcation was desobliterated in 37 (46.8%), extension into iliac arteries was necessary in 29 cases (one-sided n=4, 5.1%; both arteries n=25, 31.6%). The coeliac trunk was desobliterated in 43% (n=34), the superior mesenteric artery in 44.3% (n=35) and the inferior mesenteric artery in 20.3% (n=16). In 15 cases additional revascularisation (bypass, transposition, graft interposition) was necessary. Surgical access was via a left-sided thoracoabdominal incision in 56.4% (n=45) and via laparotomy in 41.8% (n=33). The 30-day lethality was 8.7% (n=7). Postoperative complications requiring corrective surgery occurred in 11 patients (13.9%). Almost ⅓ of the patients (n=19

  7. Storage ring at HIE-ISOLDE Technical design report

    NARCIS (Netherlands)

    Grieser, M.; Litvinov, Yu. A.; Raabe, R.; Blaum, K.; Blumenfeld, Y.; Butler, P. A.; Wenander, F.; Woods, P. J.; Aliotta, M.; Andreyev, A.; Artemyev, A.; Atanasov, D.; Aumann, T.; Balabanski, D.; Barzakh, A.; Batist, L.; Bernardes, A. -P.; Bernhardt, D.; Billowes, J.; Bishop, S.; Borge, M.; Borzov, I.; Boston, A. J.; Brandau, C.; Catford, W.; Catherall, R.; Cederkall, J.; Cullen, D.; Davinson, T.; Dillmann, I.; Dimopoulou, C.; Dracoulis, G.; Duellmann, Ch. E.; Egelhof, P.; Estrade, A.; Fischer, D.; Flanagan, K.; Fraile, L.; Fraser, M. A.; Freeman, S. J.; Geissel, H.; Gerl, J.; Greenlees, P.; Grisenti, R. E.; Habs, D.; von Hahn, R.; Hagmann, S.; Hausmann, M.; He, J. J.; Heil, M.; Huyse, M.; Jenkins, D.; Jokinen, A.; Jonson, B.; Joss, D. T.; Kadi, Y.; Kalantar-Nayestanaki, N.; Kay, B. P.; Kiselev, O.; Kluge, H. -J.; Kowalska, M.; Kozhuharov, C.; Kreim, S.; Kroell, T.; Kurcewicz, J.; Labiche, M.; Lemmon, R. C.; Lestinsky, M.; Lotay, G.; Ma, X. W.; Marta, M.; Meng, J.; Muecher, D.; Mukha, I.; Mueller, A.; Murphy, A. St J.; Neyens, G.; Nilsson, T.; Nociforo, C.; Noertershaeuser, W.; Page, R. D.; Pasini, M.; Petridis, N.; Pietralla, N.; Pfuetzner, M.; Podolyak, Z.; Regan, P.; Reed, M. W.; Reifarth, R.; Reiter, P.; Repnow, R.; Riisager, K.; Rubio, B.; Sanjari, M. S.; Savin, D. W.; Scheidenberger, C.; Schippers, S.; Schneider, D.; Schuch, R.; Schwalm, D.; Schweikhard, L.; Shubina, D.; Siesling, E.; Simon, H.; Simpson, J.; Smith, J.; Sonnabend, K.; Steck, M.; Stora, T.; Stoehlker, T.; Sun, B.; Surzhykov, A.; Suzaki, F.; Tarasov, O.; Trotsenko, S.; Tu, X. L.; Van Duppen, P.; Volpe, C.; Voulot, D.; Walker, P. M.; Wildner, E.; Winckler, N.; Winters, D. F. A.; Wolf, A.; Xu, H. S.; Yakushev, A.; Yamaguchi, T.; Yuan, Y. J.; Zhang, Y. H.; Zuber, K.; Bosch, F.M.

    We propose to install a storage ring at an ISOL-type radioactive beam facility for the first time. Specifically, we intend to setup the heavy-ion, low-energy ring TSR at the HIE-ISOLDE facility in CERN, Geneva. Such a facility will provide a capability for experiments with stored secondary beams

  8. Evaluation of the Vasoplegic impact of Papaverine in the rat aorta

    International Nuclear Information System (INIS)

    Yavuz, C.; Callskan, A.; Karahan, O.; Demirtas, S.; Yazici, S.; Guclu, O.; Mavitas, B.; Donmez, S.; Peker, R. O.; Yildirim, Y.; Gokalp, O.

    2014-01-01

    Objective: To identify the degree of vasoplegic affinity of papaverine to rat thoracic aortas following constriction caused by adrenalin, serotonin and potassium chloride in an in-vitro model. Methods: The in vitro vasoplegic efficacy of papaverine against adrenalin (10-5 M), serotonin (5HT) (10-4 M), and KCl (60 mM) was assessed, using a rat aortic vasospasm model in an organ bath. First, aortic rings were constricted with a submaximal dose of vasoconstrictor agents. The samples were then incubated with papaverine (3x10-4 M) for 20 minutes, followed by readministration of the same vasoconstrictor agents. The first vasospastic response (before papaverine incubation) and the new vasoconstrictor responses (after papaverine incubation) of the vessels were then compared. Results: The vasoplegic effect of vasoconstrictor agents in decreasing order was observed as adrenalin>KCl>5HT. This different affinity for the vasoplegic effect is considered to be a temporary impact of the drugs and the maximal inhibition of vasoconstriction was detected for the adrenalin receptor. Conclusion: The relevance of the macromolecules is responsible for the permanent efficacy of the drugs. Different degrees of vasoconstriction were also obtained after papaverine administration, which suggests that different responses can occur as a result of different stimulation of receptor modulators. (author)

  9. Token Ring Project

    Directory of Open Access Journals (Sweden)

    Adela Ionescu

    2007-01-01

    Full Text Available Ring topology is a simple configuration used to connect processes that communicate among themselves. A number of network standards such as token ring, token bus, and FDDI are based on the ring connectivity. This article will develop an implementation of a ring of processes that communicate among themselves via pipe links. The processes are nodes in the ring. Each process reads from its standard input and writes in its standard output. N-1 process redirects the its standard output to a standard input of the process through a pipe. When the ring-structure is designed, the project can be extended to simulate networks or to implement algorithms for mutual exclusion

  10. Token ring technology report

    CERN Document Server

    2013-01-01

    Please note this is a Short Discount publication. This report provides an overview of the IBM Token-Ring technology and products built by IBM and compatible vendors. It consists of two sections: 1. A summary of the design trade-offs for the IBM Token-Ring. 2. A summary of the products of the major token-ring compatible vendors broken down by adapters and components, wiring systems, testing, and new chip technology.

  11. Radioactive gold ring dermatitis

    International Nuclear Information System (INIS)

    Miller, R.A.; Aldrich, J.E.

    1990-01-01

    A superficial squamous cell carcinoma developed in a woman who wore a radioactive gold ring for more than 30 years. Only part of the ring was radioactive. Radiation dose measurements indicated that the dose to basal skin layer was 2.4 Gy (240 rad) per week. If it is assumed that the woman continually wore her wedding ring for 37 years since purchase, she would have received a maximum dose of approximately 4600 Gy

  12. Abdominal aorta coarctation: The first three case reports in our literature

    OpenAIRE

    Gajin Predrag; Tanasković Slobodan; Nenezić Dragoslav; Ilijevski Nenad; Radak Đorđe

    2010-01-01

    Introduction. Congenital coarctation of the thoracic aorta at the ligamentum arteriosum or the aortic arch is well recognized. But a much less common variety (0.5-2.0%) of aortic coarctation is located in the distal thoracic aorta or abdominal aorta or both and is often called 'middle aortic syndrome' or 'midaortic dysplastic syndrome'. This represents serious pathological condition and indicates multidisciplinary therapy approach. Outline of Cases. From 1996 to 2007, at the Vascular Surgery ...

  13. Physics of quantum rings

    International Nuclear Information System (INIS)

    Fomin, Vladimir M.

    2014-01-01

    Presents the new class of materials of quantum rings. Provides an elemental basis for low-cost high-performance devices promising for electronics, optoelectronics, spintronics and quantum information processing. Explains the physical properties of quantum rings to cover a gap in scientific literature. Presents the application of most advanced nanoengineering and nanocharacterization techniques. This book deals with a new class of materials, quantum rings. Innovative recent advances in experimental and theoretical physics of quantum rings are based on the most advanced state-of-the-art fabrication and characterization techniques as well as theoretical methods. The experimental efforts allow to obtain a new class of semiconductor quantum rings formed by capping self-organized quantum dots grown by molecular beam epitaxy. Novel optical and magnetic properties of quantum rings are associated with non-trivial topologies at the nanoscale. An adequate characterization of quantum rings is possible on the basis of modern characterization methods of nanostructures, such as Scanning Tunneling Microscopy. A high level of complexity is demonstrated to be needed for a dedicated theoretical model to adequately represent the specific features of quantum rings. The findings presented in this book contribute to develop low-cost high-performance electronic, spintronic, optoelectronic and information processing devices based on quantum rings.

  14. Methanol fractionations of Catha edulis Frosk (Celastraceae) contracted Lewis rat aorta in vitro: a comparison between crimson and green leaves.

    Science.gov (United States)

    Mahmood, Samira Abdulla; Pavlovic, Dragan; Hoffmann, Ulrich

    2009-05-07

    The study investigated the effect of methanol extract and its fractionations obtained from Yemeni khat on the smooth muscle isometric tension in Lewis rat aortal ring preparations and compared the effects of the crimson and green leaves. Khat leaves were sorted into green (khat Light; KL) and crimson (khat Dark; KD) leaves, extracted with methanol, followed with solvent-solvent extraction (benzene, chloroform and ethylacetate). The contractile activity of the fractions was tested using aortal ring preparations. The control (phenylepherine contraction) methanol extracts contracted aortas at concentrations 250, 125 and 67.5 microg/ml buffer by 80.2%, 57.3%, 26.4% and 81.5%, 65.6%, 24.6% for KL and KD, respectively. Fractions of benzene (BF) and ethylacetate (EaF) contracted the aorta with 2 microgm, whereas, chloroform (ChF) with 1 microgm/1 ml buffer was less potent. The shape of contraction curve produced by EaF differed from that of ChF and BF of both (KL and KD). The EaF induced-contraction peaked after 3.3 +/- 0.94 mins, whereas those of BF and CHF peaked after 18.0 +/- 2.2, 19.7 +/- 0.94 mins, respectively. Pre-incubation with nifedipine (10(-6) M) insignificantly reduced the contraction induced by all fractionations, but prazosin (10(-6) M) reduced the contraction by 81.9%, 63.1%, 71.8% with p = 0.23, 0.09, 0.15 for BF, ChF and EaF of KL, respectively. It significantly reduced contraction of ChF, 64.1%; p = 0.02, and of EaF, 73.5%; p = 0.04 of KD, while the reduction in contraction of BF was 63.1%; p = 0.06. In conclusion, fractions of green and crimson Yemeni khat leaves contracted aortas of Lewis rats. Both leaves behave almost similarly. Contraction induced by chloroform fraction produced alpha-sympathetic activity.

  15. Computational modeling of blood flow in the aorta--insights into eccentric dilatation of the ascending aorta after surgery for coarctation.

    Science.gov (United States)

    Szopos, Marcela; Poussineau, Nicole; Maday, Yvon; Canniffe, Carla; Celermajer, David S; Bonnet, Damien; Ou, Phalla

    2014-10-01

    To assess whether combining a computational modeling technique with data from patient magnetic resonance imaging studies can detect different fluid dynamics and vascular biomechanical properties of the ascending and horizontal aorta in patients with angulated "gothic" arch geometry compared with those with normal "Romanesque" arch geometry after aortic coarctation repair. Advanced computational fluid dynamics techniques (coupled Navier-Stokes and elastodynamics equations) were used to predict the fluid-wall interactions in large arteries. We modeled the fluid dynamics and shear stress in the ascending and horizontal aorta in cases of "gothic" arch and normal "Romanesque" aortic arch geometry. A total of 30 patients after aortic coarctation repair prospectively underwent 3-dimensional magnetic resonance imaging angiography of the thoracic aorta. Measurements of the ascending and horizontal aorta were assessed using multiplanar reformatting images. Our computational model demonstrated that wall shear stress is greater in those with an angulated "gothic" aortic arch than in those with a "Romanesque" arch. In particular, wall shear stress affected the anterior and posterior segments of the ascending aorta and the inferior and superior segments of the horizontal aorta (vs the left and right segments). In vivo, a "gothic" arch was associated with dilatation of the ascending and horizontal aorta, which was eccentric rather than concentric (Pgothic" aortic arch after repair of coarctation. This suggests that patients with an angulated "gothic" aortic arch might warrant increased surveillance for aortic complications. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  16. Treatment of traumatic rupture of the thoracic aorta

    Directory of Open Access Journals (Sweden)

    Davidović Lazar

    2008-01-01

    Full Text Available INTRODUCTION Interest for traumatic thoracic aorta rupture stems from the fact that its number continually increases, and it can be rapidly lethal. OBJECTIVE The aim of this study is to present early and long term results as well as experiences of our team in surgical treatment of traumatic thoracic aorta rupture. METHOD Our retrospective study includes 12 patients with traumatic thoracic aorta rupture treated between 1985 and 2007. There were 10 male and two female patients of average age 30.75 years (18-74. RESULTS In six cases, primary diagnosis was established during the first seven days days after trauma, while in 6 more than one month later. In 11 cases, classical open surgical procedure was performed, while endovascular treatment was used in one patient. Three (25% patients died, while two (16.6% had paraplegia. Nine patients (75% were treated without complications, and are in good condition after a mean follow-up period of 9.7 years (from one month to 22 years. CONCLUSION Surgical treatment requires spinal cord protection to prevent paraplegia, using cardiopulmonary by-pass (three of our cases or external heparin-bonded shunts (five of our cases. Cardiopulmonary by-pass is followed with lower incidence of paraplegia, however it is not such a good solution for patients with polytrauma because of hemorrhage. The endovascular repair is a safe and feasible procedure in the acute phase, especially because of traumatic shock and polytrauma which contributes to higher mortality rate after open surgery. On the other hand, in chronic postrauamatic aortic rupture, open surgical treatment is connected with a lower mortality rate and good long-term results. There have been no published data about long-term results of endovascular treatment in the chronic phase.

  17. Essential Thrombocytosis-Associated Thromboembolism in the Abdominal Aorta

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-10-01

    Full Text Available Essential thrombocytosis (ET is a myeloproliferative disorder characterized by an anomalous increase in platelet production. Many patients with ET are asymptomatic. Few studies have reported ET-associated thromboembolism in large vessels such as the aorta. We report a patient with ET who presented with peripheral embolism from an abdominal aortic thrombus and developed acute limb ischemia. The patient underwent aortic replacement successfully. The patient’s platelet count was controlled with hydroxyurea, and no recurrence was noted over 2 years of follow-up.

  18. The AORTA Reasoning Framework - Adding Organizational Reasoning to Agents

    DEFF Research Database (Denmark)

    Jensen, Andreas Schmidt

    Intelligent agents are entities defined by, among other things, autonomy. In systems of many agents, the agents’ individual autonomy can lead to uncertainty since their behavior cannot always be predicted. Usually, this kind of uncertainty is accommodated by imposing an organization upon the system...... previously been successfully integrated into agent programming languages. However, the operationalization of an organization is usually tailored to a specific language. This makes it hard to apply the same approach to other languages and platforms. The AORTA reasoning framework distinguishes itself by being...

  19. Pseudo-dissection of ascending aorta in inferior myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Grahame K. Goode

    2011-06-01

    Full Text Available Acute aortic dissection is a cardiac emergency which can present as inferior myocardial infarction. It has high morbidity and mortality requiring prompt diagnosis and treatment. Rapid advances in noninvasive imaging modalities have facilitated the early diagnosis of this condition and in ruling out this potentially catastrophic illness. We report an interesting case of a 57 year- old -man who presented with inferior myocardial infarction requiring thrombolysis and temporary pacing wire for complete heart block. An echocardiogram was highly suspicious of aortic dissection. CT scan confirmed that the malposition of the temporary pacing wire through the aorta mimicked aortic dissection.

  20. Ischemic colitis complicating reconstruction of the abdominal aorta

    DEFF Research Database (Denmark)

    Schroeder, T V; Christoffersen, J K; Andersen, J

    1985-01-01

    A review of 23 patients with ischemic colitis after surgical treatment of the abdominal aorta disclosed a pathogenetic heterogeneous finding. Ligation of the inferior mesenteric artery, abolished collateral blood supply or nonocclusive low flow state, or both, was a common feature. An incidence o...... of 0.5 per cent was revealed for full-thickness necrosis. The mortality was 70 per cent since diagnosis was made first since perforation and peritonitis had occurred. On the basis of these findings vital prophylactic measures and diagnostic possibilities are discussed herein....

  1. EBT ring physics

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1980-04-01

    This workshop attempted to evaluate the status of the current experimental and theoretical understanding of hot electron ring properties. The dominant physical processes that influence ring formation, scaling, and their optimal behavior are also studied. Separate abstracts were prepared for each of the 27 included papers

  2. Analysis of the role of nitric oxide in the relaxant effect of the crude extract and fractions from Eugenia uniflora in the rat thoracic aorta.

    Science.gov (United States)

    Wazlawik, E; Da Silva, M A; Peters, R R; Correia, J F; Farias, M R; Calixto, J B; Ribeiro-Do-Valle, R M

    1997-04-01

    This study has evaluated the possible role played by the L-arginine-nitric oxide pathway in the vasorelaxant action of the hydroalcoholic extract from Eugenia uniflora, and fractions from the extract, in rings of rat thoracic aorta. The addition of an increasing cumulative concentration of hydroalcoholic extract from E. uniflora (1-300 micrograms mL-1) caused a concentration-dependent relaxation response in intact endothelium-thoracic aorta rings pre-contracted with noradrenaline (30-100 nM). The IC50 value, with its respective confidence limit, and the maximum relaxation (Rmax) were 7.02 (4.77-10.00) micrograms mL-1 and 83.94 +/- 3.04%, respectively. The removal of the endothelium completely abolished these responses. The nitric oxide synthase inhibitors N omega-nitro-L-arginine (L-NOARG, 30 microM) and N omega-nitro-L-arginine methyl ester (L-NAME, 30 microM), inhibited the relaxation (Rmax) to -10.43 +/- 7.81% and -3.69 +/- 2.62%, respectively. In addition, L-arginine (1 mM), but not D-arginine (1 mM), completely reversed inhibition by L-NOARG. Methylene blue (30 microM), a soluble guanylate cyclase inhibitor, reduced the relaxation induced by the extract to 14.60 +/- 7.40%. These data indicate that in the rat thoracic aorta the hydroalcoholic extract, and its fractions, from the leaves of E. uniflora have graded and endothelium-dependent vasorelaxant effects.

  3. Evaluation of atherosclerotic change of the aorta by enhanced computed tomography

    International Nuclear Information System (INIS)

    Takasu, Junichiro

    1990-01-01

    Intimal atherosclerotic changes of the aorta were quantified by enhanced computed tomography (enhanced CT) and were examined in terms of their relation to other atherosclerotic characteristics, including calcification and aortic pulse wave velocity, diameter of the aorta, and arteriosclerotic risk factors. A total of 413 subjects were studied, consisting of normal volunteers and patients with cardiovascular diseases. Enhanced CT revealed the atheromatous intima as a projecting and thickened wall. Thus, the ratio of the intimal atherosclerotic change to the whole round was determined in various aortic sites. The diameter of the aorta decreased in accordance with the location from the ascending aorta to aortic ending. The diameter of the infrarenal abdominal aorta was 1.5 times larger than that of the ascending aorta, irrespective of age. The diameter of each region of the aorta increased with advancing age; in the age group of 70 years or older, it was 1.5 times larger that that in the age group of 40 years or younger. The intimal change was noted in the middle descending thoracic aorta and infrarenal abdominal aorta. It was proportional to an increase in the aortic pulse wave velocity, the diameter of the aorta, and the intimal calcification. Intimal changes of the aorta were increased in cerebrovascular disease, ischemic heart disease, arteriosclerosis obliterans, hypertension and diabetes mellitus. In particular, hypertension accompanied by diabetes mellitus or high cholesterolemia tended to accelerate the intimal change. In conclusion, aortic intimal changes, as detected on enhanced CT, is useful for the noninvasive diagnosis of arteriosclerosis. (N.K.)

  4. Extra-Anatomic Revascularization of Extensive Coral Reef Aorta.

    Science.gov (United States)

    Gaggiano, Andrea; Kasemi, Holta; Monti, Andrea; Laurito, Antonella; Maselli, Mauro; Manzo, Paola; Quaglino, Simone; Tavolini, Valeria

    2017-10-01

    Coral reef aorta (CRA) is a rare, potential lethal disease of the visceral aorta as it can cause visceral and renal infarction. Various surgical approaches have been proposed for the CRA treatment. The purpose of this article is to report different extensive extra-anatomic CRA treatment modalities tailored on the patients' clinical and anatomic presentation. From April 2006 to October 2012, 4 symptomatic patients with extensive CRA were treated at our department. Extra-anatomic aortic revascularization with selective visceral vessels clamping was performed in all cases. Technical success was 100%. No perioperative death was registered. All patients remained asymptomatic during the follow-up period (62, 49, 25, and 94 months, respectively), with bypasses and target vessels patency. The extra-anatomic bypass with selective visceral vessels clamping reduces the aortic occlusion time and the risk of organ ischemia. All approaches available should be considered on a case-by-case basis and in high-volume centers. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Elastin aging and lipid oxidation products in human aorta

    Directory of Open Access Journals (Sweden)

    Kamelija Zarkovic

    2015-04-01

    Full Text Available Vascular aging is associated with structural and functional modifications of the arteries, and by an increase in arterial wall thickening in the intima and the media, mainly resulting from structural modifications of the extracellular matrix (ECM components. Among the factors known to accumulate with aging, advanced lipid peroxidation end products (ALEs are a hallmark of oxidative stress-associated diseases such as atherosclerosis. Aldehydes generated from the peroxidation of polyunsaturated fatty acids (PUFA, (4-hydroxynonenal, malondialdehyde, acrolein, form adducts on cellular proteins, leading to a progressive protein dysfunction with consequences in the pathophysiology of vascular aging. The contribution of these aldehydes to ECM modification is not known. This study was carried out to investigate whether aldehyde-adducts are detected in the intima and media in human aorta, whether their level is increased in vascular aging, and whether elastin fibers are a target of aldehyde-adduct formation. Immunohistological and confocal immunofluorescence studies indicate that 4-HNE-histidine-adducts accumulate in an age-related manner in the intima, media and adventitia layers of human aortas, and are mainly expressed in smooth muscle cells. In contrast, even if the structure of elastin fiber is strongly altered in the aged vessels, our results show that elastin is not or very poorly modified by 4-HNE. These data indicate a complex role for lipid peroxidation and in particular for 4-HNE in elastin homeostasis, in the vascular wall remodeling during aging and atherosclerosis development.

  6. Branches of the abdominal aorta in Aotus azarae infulatus

    Directory of Open Access Journals (Sweden)

    Bianca Mendonça Faria

    2016-05-01

    The genus Aotus is found in South America and is known for its nocturnal habit. The morphology of the genus is poorly understood even though it is used in biomedical research. The objective of this study was to identify the collateral branches of the abdominal aorta of two females and one male Aotus azarae infulatus (commonly known as the night monkey. The vessels were observed and stained with Neoprene latex and radiopaque contrast. The animals were fixed in an aqueous solution of 10% formaldehyde via intramuscular and intracavitary routes, dissected and radiographed. It was observed that the celiac artery was divided into three subjacent branches, the gastric, hepatic and splenic arteries. The left and right renal arteries originated from a common trunk in two animals (animals 1 and 2, while the adrenal artery in one of the animals was derived from the celiac trunk and renal artery (animal 2. In one animal the mesenteric artery flow gave rise to individual cranial rectal, sigmoid and left colic arteries (animal 3. In the three animals the abdominal aorta bifurcated in the final portion of the abdomen, with the external and internal iliac artery on each side, and then the median sacral artery. These anatomical variations need to be identified and reported because these animals are frequently used in clinical and surgical, veterinary practices.

  7. On the Laurent polynomial rings

    International Nuclear Information System (INIS)

    Stefanescu, D.

    1985-02-01

    We describe some properties of the Laurent polynomial rings in a finite number of indeterminates over a commutative unitary ring. We study some subrings of the Laurent polynomial rings. We finally obtain two cancellation properties. (author)

  8. Aortocaval fistula: an infrequent complication of aneurysm of the abdominal aorta; Fistula aortocava: complicacion infrecuente tras rotura de aneurisma de aorta abdominal

    Energy Technology Data Exchange (ETDEWEB)

    Alpera, R.; Ardoy, F.; Gallego, J. A.

    2002-07-01

    A case is reported of aortocaval fistula (ACF) as an infrequent complication of an aneurysm of the abdominal aorta (AAA) that debuted clinically with pain in the right lumbar fossa and kidney failure. the diagnosis was made by helicoid computed tomography (HCT) and confirmed surgery. HCT findings consisted of an early accentuation of the inferior vena cava (ICV) in the arterial phase, and visualization of the communication between the aorta and inferior vena cava. (Author) 8 refs.

  9. Heterogeneity of smooth muscle cells in tunica media of aorta in ...

    African Journals Online (AJOL)

    ... of the tunica media of goat aorta are phenotypically heterogeneous and run in multiple directions. These characteristics probably confer mechanical strength and functional plasticity to the aortic wall. Designers of aortic substitutes should bear this in mind. Keywords: Vascular, Smooth Muscle Cells, Heterogeneity, Aorta ...

  10. Improved protein extraction and protein identification from archival formalin-fixed paraffin-embedded human aortas.

    Science.gov (United States)

    Fu, Zongming; Yan, Kun; Rosenberg, Avraham; Jin, Zhicheng; Crain, Barbara; Athas, Grace; Heide, Richard S Vander; Howard, Timothy; Everett, Allen D; Herrington, David; Van Eyk, Jennifer E

    2013-04-01

    Evaluate combination of heat and elevated pressure to enhance protein extraction and quality of formalin-fixed (FF), and FF paraffin-embedded (FFPE) aorta for proteomics. Proteins were extracted from fresh frozen aorta at room temperature (RT). FF and FFPE aortas (3 months and 15 years) were extracted at RT, heat alone, or a combination of heat and high pressure. Protein yields were compared, and digested peptides from the extracts were analyzed with MS. Combined heat and elevated pressure increased protein yield from human FF or FFPE aorta compared to matched tissues with heat alone (1.5-fold) or at RT (8.3-fold), resulting in more proteins identified and with more sequence coverage. The length of storage did adversely affect the quality of proteins from FF tissue. For long-term storage, aorta was preserved better with FFPE than FF alone. Periostin and MGF-E8 were demonstrated suitable for MRM assays from FFPE aorta. Combination of heat and high pressure is an effective method to extract proteins from FFPE aorta for downstream proteomics. This method opens the possibility for use of archival and often rare FFPE aortas and possibly other tissues available to proteomics for biomarker discovery and quantification. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Heavy ion storage rings

    International Nuclear Information System (INIS)

    Schuch, R.

    1987-01-01

    A brief overview of synchrotron storage rings for heavy ions, which are presently under construction in different accelerator laboratories is given. Ions ranging from protons up to uranium ions at MeV/nucleon energies will be injected into these rings using multiturn injection from the accelerators available or being built in these laboratories. After injection, it is planned to cool the phase space distribution of the ions by merging them with cold electron beams or laser beams, or by using stochastic cooling. Some atomic physics experiments planned for these rings are presented. 35 refs

  12. Faithfully quadratic rings

    CERN Document Server

    Dickmann, M

    2015-01-01

    In this monograph the authors extend the classical algebraic theory of quadratic forms over fields to diagonal quadratic forms with invertible entries over broad classes of commutative, unitary rings where -1 is not a sum of squares and 2 is invertible. They accomplish this by: (1) Extending the classical notion of matrix isometry of forms to a suitable notion of T-isometry, where T is a preorder of the given ring, A, or T = A^2. (2) Introducing in this context three axioms expressing simple properties of (value) representation of elements of the ring by quadratic forms, well-known to hold in

  13. MR imaging of the thoracic aorta in patients with Marfan syndrome

    International Nuclear Information System (INIS)

    Sommerhoff, B.A.; Sechtem, U.P.; Schiller, N.B.; Higgins, C.B.

    1986-01-01

    Gated MR imaging was used to evaluate the thoracic aorta in 11 with Marfan syndrome, eight patients with aneurysm of the ascending aorta, and 20 healthy subjects. The aortic diameter was measured on transverse and sagittal images at the levels of the sinuses of Valsalva, the caudal portion of the ascending aorta, the prearch region, the middle arch, and the descending aorta. The sinus of Valsalva-prearch region aortic diameter ratio in patients with Marfan syndrome was significantly greater than in the two other groups, indicating the characteristic shape of the Maranoid aorta. MR imaging allows definitive measurements' of aortic dimensions and is a valuable noninvasive method for monitoring the course of aortic enlargement

  14. Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions

    Energy Technology Data Exchange (ETDEWEB)

    Kurugol, Sila, E-mail: sila.kurugol@childrens.harvard.edu; Come, Carolyn E.; Diaz, Alejandro A.; Ross, James C.; Washko, George R.; San Jose Estepar, Raul [Brigham and Women’s Hospital and Harvard Medical School, Boston, Massachusetts 02115 (United States); Kinney, Greg L.; Black-Shinn, Jennifer L.; Hokanson, John E. [Colorado School of Public Health, University of Colorado Denver, Aurora, Colorado 80045 (United States); Budoff, Matthew J. [Los Angeles Biomedical Research Center at Harbor and UCLA Medical Center, Torrance, California 90502 (United States)

    2015-09-15

    Purpose: The purpose of this work is to develop a fully automated pipeline to compute aorta morphology and calcification measures in large cohorts of CT scans that can be used to investigate the potential of these measures as imaging biomarkers of cardiovascular disease. Methods: The first step of the automated pipeline is aorta segmentation. The algorithm the authors propose first detects an initial aorta boundary by exploiting cross-sectional circularity of aorta in axial slices and aortic arch in reformatted oblique slices. This boundary is then refined by a 3D level-set segmentation that evolves the boundary to the location of nearby edges. The authors then detect the aortic calcifications with thresholding and filter out the false positive regions due to nearby high intensity structures based on their anatomical location. The authors extract the centerline and oblique cross sections of the segmented aortas and compute the aorta morphology and calcification measures of the first 2500 subjects from COPDGene study. These measures include volume and number of calcified plaques and measures of vessel morphology such as average cross-sectional area, tortuosity, and arch width. Results: The authors computed the agreement between the algorithm and expert segmentations on 45 CT scans and obtained a closest point mean error of 0.62 ± 0.09 mm and a Dice coefficient of 0.92 ± 0.01. The calcification detection algorithm resulted in an improved true positive detection rate of 0.96 compared to previous work. The measurements of aorta size agreed with the measurements reported in previous work. The initial results showed associations of aorta morphology with calcification and with aging. These results may indicate aorta stiffening and unwrapping with calcification and aging. Conclusions: The authors have developed an objective tool to assess aorta morphology and aortic calcium plaques on CT scans that may be used to provide information about the presence of cardiovascular

  15. Effects of hirsutine, an antihypertensive indole alkaloid from Uncaria rhynchophylla, on intracellular calcium in rat thoracic aorta.

    Science.gov (United States)

    Horie, S; Yano, S; Aimi, N; Sakai, S; Watanabe, K

    1992-01-01

    The effects of hirsutine, an indole alkaloid from Uncaria rhynchophylla (MIQ.) Jackson, on cytosolic Ca2+ level ([Ca2+]cyt) were studied by using fura-2-Ca2+ fluorescence in smooth muscle of the isolated rat aorta. Noradrenaline and high K+ solution produced a sustained increase in [Ca2+]cyt. Application of hirsutine after the increases in [Ca2+]cyt induced by noradrenaline and high K+ notably decreased [Ca2+]cyt, suggesting that hirsutine inhibits Ca2+ influx mainly through a voltage-dependent Ca2+ channel. Furthermore, the effect of hirsutine on intracellular Ca2+ store was studied by using contractile responses to caffeine under the Ca(2+)-free nutrient condition in the rat aorta. When hirsutine was added at 30 microM before caffeine treatment, the agent slightly but significantly reduced the caffeine-induced contraction. When added during Ca2+ loading, hirsutine definitely augmented the contractile response to caffeine. These results suggest that hirsutine inhibits Ca2+ release from the Ca2+ store and increases Ca2+ uptake into the Ca2+ store, leading to a reduction of intracellular Ca2+ level. It is concluded that hirsutine reduces intracellular Ca2+ level through its effect on the Ca2+ store as well as through its effect on the voltage-dependent Ca2+ channel.

  16. On arbitrarily graded rings

    Indian Academy of Sciences (India)

    58

    paper is devoted to the study of arbitrary rings graded through arbitrary sets. .... which recover certain multiplicative relations among the homogeneous components ... instance the case in which the grading set A is an Abelian group, where the ...

  17. The g-2 ring

    CERN Multimedia

    1974-01-01

    The precise measurement of "g-2", the anomalous magnetic moment of the muon, required a special muon storage ring with electrostatic focussing and very accurate knowledge of the magnetic bending field. For more details see under photo 7405430.

  18. [Liesegang's rings resembling helminthiasis].

    Science.gov (United States)

    Zámecník, M; Riedl, I

    1996-12-01

    So called Liesegang's rings are lamellar corpuscles which develop after periodical precipitation of oversaturated solutions in gel medium. They can occur in cysts, closed cavities, inflammatory exudates and necroses. They resemble parasitic eggs, larvae or adult forms. A case of 28-year-old woman is presented with many Liesegang's rings in a stuff from dilated renal calyx. Their preliminary evaluation considered helminths, especially Dioctophyma renale.

  19. Storage ring group summary

    International Nuclear Information System (INIS)

    King, N.M.

    1980-01-01

    The Storage Ring Group set out to identify and pursue salient problems in accelerator physics for heavy ion fusion, divorced from any particular reference design concept. However, it became apparent that some basic parameter framework was required to correlate the different study topics. As the Workshop progressed, ring parameters were modified and updated. Consequently, the accompanying papers on individual topics will be found to refer to slightly varied parameters, according to the stage at which the different problems were tackled

  20. The rings of Uranus

    Science.gov (United States)

    Elliot, J. L.; Dunham, E.; Mink, D.

    1977-01-01

    A description is given of the observation of five brief occultations of the star SAO 158687 which occurred both before and after its occultation by Uranus on March 10, 1977. The events were observed with a three-channel occultation photometer, attached to a 91-cm telescope. The observations indicate that at least five rings encircle the planet Uranus. Possible reasons for the narrowness of the Uranus rings are discussed.

  1. Quantitative analysis of calcification of the abdominal aorta by CT

    International Nuclear Information System (INIS)

    Watanabe, Hiromi; Kubota, Kazuo; Ito, Kengo; Ono, Shuichi; Matsuzawa, Taiju

    1983-01-01

    Of the abdominal aorta, the relationship between the calcification index (C.I.) obtained from CT films and the atheromatous surface involved (S.I.) obtained from autopsy specimens was studied. The relations of C.I. to hypertension and hyperlipidemia were also analyzed. The coefficient of correlation between C.I. and S.I. was 0.83 (p< 0.001). Compared with a non-hypertensive group, the hypertensives showed a higher C.I., and such a difference was great in the male patients in their 50s and females in their 60s and 70s. The male patients with hyperlipidemia did not show definite differences in C.I. from the non-hyperlipidemia group, but the female patients in their 60s and 70s showed significantly higher values. (Chiba, N.)

  2. [Congenital abnormalities of the aorta in children and adolescents].

    Science.gov (United States)

    Eichhorn, J G; Ley, S

    2007-11-01

    Aortic abnormalities are common cardiovascular malformations accounting for 15-20% of all congenital heart disease. Ultrafast CT and MR imaging are noninvasive, accurate and robust techniques that can be used in the diagnosis of aortic malformations. While their sensitivity in detecting vascular abnormalities seems to be as good as that of conventional catheter angiocardiography, at over 90%, they are superior in the diagnosis of potentially life-threatening complications, such as tracheal, bronchial, or esophageal compression. It has been shown that more than 80% of small children with aortic abnormalities benefit directly from the use of noninvasive imaging: either cardiac catheterization is no longer necessary or radiation doses and periods of general anesthesia for interventional catheterization procedures can be much reduced. The most important congenital abnormalities of the aorta in children and adolescents are presented with reference to examples, and the value of CT and MR angiography is documented.

  3. Ayahuasca Alters Structural Parameters of the Rat Aorta.

    Science.gov (United States)

    Pitol, Dimitrius L; Siéssere, Selma; Dos Santos, Rafael G; Rosa, Maria L N M; Hallak, Jaime E C; Scalize, Priscilla H; Pereira, Bruno F; Iyomasa, Melina M; Semprini, Marisa; Riba, Jordi; Regalo, Simone C H

    2015-07-01

    Ayahuasca is a hallucinogenic brew traditionally used by Northwestern Amazonian indigenous groups for therapeutic purposes. It is prepared by the decoction of Banisteriopsis caapi with the leaves of Psychotria viridis. Banisteriopsis caapi contains β-carbolines that are inhibitors of monoamine oxidase and P. viris is rich in dimethyltryptamine, a 5-HT(1A/2A/2C) agonist. Acute ayahuasca administration produces moderate cardiovascular effects in healthy volunteers, but information regarding long-term use is lacking. This study investigated the effects of ayahuasca (2-4 mL/kg) in the rat aorta after acute and chronic (14 days) administration. Ayahuasca caused flattening and stretching of vascular smooth muscle cells and changes in the arrangement and distribution of collagen and elastic fibers. Chronic treatment with the higher dose significantly increased media thickness and the ratio of media thickness to lumen diameter. More research is needed on the cardiovascular function of long-term ayahuasca consumers.

  4. Basal lamina structural alterations in human asymmetric aneurismatic aorta

    Directory of Open Access Journals (Sweden)

    M Cotrufo

    2009-06-01

    Full Text Available Basal lamina (BL is a crucial mechanical and functional component of blood vessels, constituting a sensor of extracellular microenvironment for endothelial cells and pericytes. Recently, an abnormality in the process of matrix microfibrillar component remodeling has been advocated as a mechanism involved in the development of aortic dilation.We focused our attention on BL composition and organization and studied some of the main components of the Extracellular Matrix such as Tenascin, Laminins, Fibronectin, type I, III and IV Collagens.We used surgical fragments from 27 patients, submitted to operation because of aortic root aneurysm and 5 normal aortic wall specimens from heart donors without any evidence for aneurysmal or atherosclerotic diseases of the aorta. Two samples of aortic wall were harvested from each patient, proximal to the sinotubular junction at the aortic convexity and concavity. Each specimen was processed both for immunohistochemical examination and molecular biology study.We compared the convexity of each aortic sample with the concavity of the same vessel, and both of them with the control samples. The synthesis of mRNA and the levels of each protein were assessed, respectively, by RTPCR and Western Blot analysis. Immunohistochemistry elucidated the organization of BL, whose composition was revealed by molecular biology. All pathological samples showed a wall thinner than normal ones. Basal lamina of the aortic wall evidentiated important changes in the tridimensional arrangement of its major components which lost their regular arrangement in pathological specimens. Collagen I, Laminin a2 chain and Fibronectin amounts decreased in pathological samples, while type IV Collagen and Tenascin synthesis increased. Consistently with the common macroscopic observation that ascending aorta dilations tend to expand asymmetrically, with prevalent involvement of the vessel convexity and relative sparing of the concavity, Collagen type

  5. Elastin aging and lipid oxidation products in human aorta.

    Science.gov (United States)

    Zarkovic, Kamelija; Larroque-Cardoso, Pauline; Pucelle, Mélanie; Salvayre, Robert; Waeg, Georg; Nègre-Salvayre, Anne; Zarkovic, Neven

    2015-01-01

    Vascular aging is associated with structural and functional modifications of the arteries, and by an increase in arterial wall thickening in the intima and the media, mainly resulting from structural modifications of the extracellular matrix (ECM) components. Among the factors known to accumulate with aging, advanced lipid peroxidation end products (ALEs) are a hallmark of oxidative stress-associated diseases such as atherosclerosis. Aldehydes generated from the peroxidation of polyunsaturated fatty acids (PUFA), (4-hydroxynonenal, malondialdehyde, acrolein), form adducts on cellular proteins, leading to a progressive protein dysfunction with consequences in the pathophysiology of vascular aging. The contribution of these aldehydes to ECM modification is not known. This study was carried out to investigate whether aldehyde-adducts are detected in the intima and media in human aorta, whether their level is increased in vascular aging, and whether elastin fibers are a target of aldehyde-adduct formation. Immunohistological and confocal immunofluorescence studies indicate that 4-HNE-histidine-adducts accumulate in an age-related manner in the intima, media and adventitia layers of human aortas, and are mainly expressed in smooth muscle cells. In contrast, even if the structure of elastin fiber is strongly altered in the aged vessels, our results show that elastin is not or very poorly modified by 4-HNE. These data indicate a complex role for lipid peroxidation and in particular for 4-HNE in elastin homeostasis, in the vascular wall remodeling during aging and atherosclerosis development. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  7. Infrarenal aorta as the donor site for bypasses to the superior mesenteric artery for chronic mesenteric ischemia: A prospective clinical series of 24 patients.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco G; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2017-11-01

    infrarenal aortic grafts are an excellent source for the revascularization of the superior mesenteric artery. Bypasses to the superior mesenteric artery from the infrarenal aorta, either isolated or associated with adjunctive bypass to the inferior mesenteric artery, yield results that are comparable with those obtained with complete digestive artery revascularization using other donor sources. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. In vitro vasorelaxation mechanisms of bioactive compounds extracted from Hibiscus sabdariffa on rat thoracic aorta

    Science.gov (United States)

    Sarr, Mamadou; Ngom, Saliou; Kane, Modou O; Wele, Alassane; Diop, Doudou; Sarr, Bocar; Gueye, Lamine; Andriantsitohaina, Ramaroson; Diallo, Aminata S

    2009-01-01

    Background In this study, we suggested characterizing the vasodilator effects and the phytochemical characteristics of a plant with food usage also used in traditional treatment of arterial high blood pressure in Senegal. Methods Vascular effects of crude extract of dried and powdered calyces of Hibiscus sabdariffa were evaluated on isolated thoracic aorta of male Wistar rats on organ chambers. The crude extract was also enriched by liquid-liquid extraction. The various cyclohexane, dichloromethane, ethyl acetate, butanol extracts obtained as well as the residual marc were subjected to Sephadex LH-20 column chromatography. The different methanolic eluate fractions were then analyzed by Thin Layer (TLC) and High Performance Liquid Chromatography (HPLC) and their vascular effects also evaluated. Results The H. Sabdariffa crude extract induced mainly endothelium-dependent relaxant effects. The endothelium-dependent relaxations result from NOS activation and those who not dependent to endothelium from activation of smooth muscle potassium channels. The phytochemical analysis revealed the presence of phenolic acids in the ethyl acetate extract and anthocyans in the butanolic extract. The biological efficiency of the various studied extracts, in term of vasorelaxant capacity, showed that: Butanol extract > Crude extract > Residual marc > Ethyl acetate extract. These results suggest that the strong activity of the butanolic extract is essentially due to the presence of anthocyans found in its fractions 43-67. Conclusion These results demonstrate the vasodilator potential of hibiscus sabdariffa and contribute to his valuation as therapeutic alternative. PMID:19883513

  9. Computed tomography evaluation of traumatic rupture of the thoracic aorta: an outcome study

    International Nuclear Information System (INIS)

    Ellis, J.D.; Mayo, J.R.

    2007-01-01

    To assess the long-term outcome of blunt trauma patients with suspected thoracic aortic or great vessel injury that was evaluated with contrast-enhanced chest computed tomography (CT). We studied the outcome of 278 consecutive patients who received contrast enhanced CT for blunt chest trauma with computerized searches of the regional trauma database, hospital medical records, universal government medical coverage plan billing records, and regional vital statistics databases. Data retrieved included patient demographics, mechanism of injury, status of the aorta and proximal great vessels at contrast-enhanced CT, hospital discharge diagnoses, and outpatient procedural billings with specific attention to aortic or great vessel injury. Median follow-up was 615 days following the traumatic event. Six subjects demonstrated direct signs of aortic or proximal great vessel injury on contrast-enhanced chest CT, as follows: aortic pseudoaneurysm and intimal flap (n = 4), carotid artery dissection (n = 1), and aortic dissection (n 1). All were surgically treated, except the patient with aortic dissection, who was treated medically. In the other subjects, contrast-enhanced CT was negative (n = 230) or showed isolated mediastinal hematoma (n = 42). The computerized searches of the medical databases showed that none of these 272 subjects had procedures for, or died from, aortic or great vessel injury during the follow-up period. Computerized searches of medical databases found no evidence of missed thoracic aortic or proximal great vessel injury in blunt trauma patients who were evaluated with contrast-enhanced chest CT. (author)

  10. Vasorelaxant effect of the analgesic clonixin on rat aorta.

    Science.gov (United States)

    Morales, M A; Silva, A; Brito, G; Bustamante, S; Ponce, H; Paeile, C

    1995-03-01

    1. A novel vasorelaxant effect of clonixinate of L-lysine (Clx), analgesic and anti-inflammatory, was studied in rat aortic rings. 2. Clx completely relaxed aortic rings contracted by KCl 70 mM and together with its analog flunixin exhibited lesser potency but equal efficacy than verapamil. In comparison, indomethacin, which is a more potent cyclo-oxygenase inhibitor relaxed only about 40% of the maximal contraction of aortic rings. 3. Furthermore, Clx antagonized Ca2+ dependent aortic contraction and BAY K-8644 induced aortic contraction suggesting its calcium antagonist character. 4. From these results it can be concluded that the hypotensive effect seen in rats in vivo after Clx i.v. injection arises because of vasodilatory effect of Clx and gives further support to the proposal that the pharmacological mechanism of action of Clx should be calcium antagonism.

  11. Some Aspects of Ring Theory

    CERN Document Server

    Herstein, IN

    2011-01-01

    S. Amitsur: Associative rings with identities.- I.N. Herstein: Topics in ring theory.- N. Jacobson: Representation theory of Jordan algebras.- I. Kaplansky: The theory of homological dimension.- D. Buchsbaum: Complexes in local ring theory.- P.H. Cohn: Two topics in ring theory.- A.W. Goldie: Non-commutative localisation.

  12. Assessment of the accuracy of AortaScan for detection of abdominal aortic aneurysm (AAA).

    Science.gov (United States)

    Abbas, A; Smith, A; Cecelja, M; Waltham, M

    2012-02-01

    AortaScan AMI 9700 is a portable 3D ultrasound device that automatically measures the maximum diameter of the abdominal aorta without the need for a trained sonographer. It is designed to rapidly diagnose or exclude an AAA and may have particular use in screening programs. Our objective was to determine its accuracy to detect AAA. Subjects from our AAA screening and surveillance programs were examined. The aorta was scanned using the AortaScan and computed tomography (CT). Ninety-one subjects underwent imaging (44 AAA on conventional ultrasound surveillance and 47 controls). The largest measurement obtained by AortaScan was compared against the CT-aortic measurement. The mean aortic diameter was 2.8 cm. The CT scan confirmed the diagnosis of AAA in 43 subjects. There was one false positive measurement on conventional ultrasound. AortaScan missed the diagnosis of AAA in eight subjects. There were thirteen false positive measurements. The sensitivity, specificity, positive and negative predictive values were 81%, 72%, 72% and 81% respectively. A device to detect AAA without the need for a trained operator would have potential in a community-based screening programme. The AortaScan, however, lacks adequate sensitivity and significant technical improvement is necessary before it could be considered a replacement for trained screening personnel. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Ring correlations in random networks.

    Science.gov (United States)

    Sadjadi, Mahdi; Thorpe, M F

    2016-12-01

    We examine the correlations between rings in random network glasses in two dimensions as a function of their separation. Initially, we use the topological separation (measured by the number of intervening rings), but this leads to pseudo-long-range correlations due to a lack of topological charge neutrality in the shells surrounding a central ring. This effect is associated with the noncircular nature of the shells. It is, therefore, necessary to use the geometrical distance between ring centers. Hence we find a generalization of the Aboav-Weaire law out to larger distances, with the correlations between rings decaying away when two rings are more than about three rings apart.

  14. Origem anômala de uma artéria pulmonar da aorta ascendente: resolução da hipertensão arterial pulmonar com a correção cirúrgica Anomalous origin of one pulmonary artery from the ascending aorta: surgical repair resolving pulmonary arterial hypertension

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Santos

    2004-12-01

    artery originated from the ascending aorta in association with a large interventricular septal defect. The pressure level in both pulmonary arteries in all infants was that of the systemic level. All patients underwent surgery, which consisted of translocation of the anomalous pulmonary artery from the aorta. Neither immediate nor late cardiac deaths occurred. CONCLUSION: Once the diagnosis of anomalous origin of the pulmonary artery from the ascending aorta in the isolated form is established, the surgical correction should be immediately performed, not only because of the risk of developing pulmonary vascular disease, but also because of the excellent surgical results currently obtained.

  15. Mapping Ring Particle Cooling across Saturn's Rings with Cassini CIRS

    Science.gov (United States)

    Brooks, Shawn M.; Spilker, L. J.; Edgington, S. G.; Pilorz, S. H.; Deau, E.

    2010-10-01

    Previous studies have shown that the rings' thermal inertia, a measure of their response to changes in the thermal environment, varies from ring to ring. Thermal inertia can provide insight into the physical structure of Saturn's ring particles and their regoliths. Low thermal inertia and quick temperature responses are suggestive of ring particles that have more porous or fluffy regoliths or that are riddled with cracks. Solid, coherent particles can be expected to have higher thermal inertias (Ferrari et al. 2005). Cassini's Composite Infrared Spectrometer has recorded millions of spectra of Saturn's rings since its arrival at Saturn in 2004 (personal communication, M. Segura). CIRS records far infrared radiation between 10 and 600 cm-1 (16.7 and 1000 µm) at focal plane 1 (FP1), which has a field of view of 3.9 mrad. Thermal emission from Saturn's rings peaks in this wavelength range. FP1 spectra can be used to infer ring temperatures. By tracking how ring temperatures vary, we can determine the thermal inertia of the rings. In this work we focus on CIRS observations of the shadowed portion of Saturn's rings. The thermal budget of the rings is dominated by the solar radiation absorbed by its constituent particles. When ring particles enter Saturn's shadow this source of energy is abruptly cut off. As a result, ring particles cool as they traverse Saturn's shadow. From these shadow observations we can create cooling curves at specific locations across the rings. We will show that the rings' cooling curves and thus their thermal inertia vary not only from ring to ring, but by location within the individual rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2010 California Institute of Technology. Government sponsorship acknowledged.

  16. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changwu [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Qiao, Huiyu; He, Le [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Yuan, Chun [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, University of Washington, Seattle, WA (United States); Chen, Huijun; Zhang, Qiang; Li, Rui [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Wang, Wei; Du, Fang [Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Li, Cheng, E-mail: cjr.licheng@vip.163.com [Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing (China); Zhao, Xihai, E-mail: xihaizhao@tsinghua.edu.cn [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China)

    2016-11-15

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  17. Low Density Lipoprotein and Non-Newtonian Oscillating Flow Biomechanical Parameters for Normal Human Aorta.

    Science.gov (United States)

    Soulis, Johannes V; Fytanidis, Dimitrios K; Lampri, Olga P; Giannoglou, George D

    2016-04-01

    The temporal variation of the hemodynamic mechanical parameters during cardiac pulse wave is considered as an important atherogenic factor. Applying non-Newtonian blood molecular viscosity simulation is crucial for hemodynamic analysis. Understanding low density lipoprotein (LDL) distribution in relation to flow parameters will possibly spot the prone to atherosclerosis aorta regions. The biomechanical parameters tested were averaged wall shear stress (AWSS), oscillatory shear index (OSI) and relative residence time (RRT) in relation to the LDL concentration. Four non-Newtonian molecular viscosity models and the Newtonian one were tested for the normal human aorta under oscillating flow. The analysis was performed via computational fluid dynamic. Tested viscosity blood flow models for the biomechanical parameters yield a consistent aorta pattern. High OSI and low AWSS develop at the concave aorta regions. This is most noticeable in downstream flow region of the left subclavian artery and at concave ascending aorta. Concave aorta regions exhibit high RRT and elevated LDL. For the concave aorta site, the peak LDL value is 35.0% higher than its entrance value. For the convex site, it is 18.0%. High LDL endothelium regions located at the aorta concave site are well predicted with high RRT. We are in favor of using the non-Newtonian power law model for analysis. It satisfactorily approximates the molecular viscosity, WSS, OSI, RRT and LDL distribution. Concave regions are mostly prone to atherosclerosis. The flow biomechanical factor RRT is a relatively useful tool for identifying the localization of the atheromatic plaques of the normal human aorta.

  18. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    International Nuclear Information System (INIS)

    Zhou, Changwu; Qiao, Huiyu; He, Le; Yuan, Chun; Chen, Huijun; Zhang, Qiang; Li, Rui; Wang, Wei; Du, Fang; Li, Cheng; Zhao, Xihai

    2016-01-01

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  19. The Rings of Saturn

    Science.gov (United States)

    Cuzzi, J. N.; Filacchione, G.; Marouf, E. A.

    2018-03-01

    One could become an expert on Saturn's iconic rings pretty easily in the early 1970s, as very little was known about them beyond the distinction between the A, B, and C rings, and the Cassini Division or "gap" between rings A and B (Alexander, 1962; Bobrov, 1970). Water ice was discovered spectroscopically on the ring particle surfaces, and radar and microwave emission observations proved that the particles must be centimeters to meters in size, consisting primarily, not just superficially, of water ice (Pollack, 1975). While a 2:1 orbital resonance with Mimas had long been suspected of having something to do with the Cassini Division, computers of the time were unable to model the subtle dynamical effects that we now know to dominate ring structure. This innocent state of affairs was exploded by the Voyager 1 and 2 encounters in 1980 and 1981. Spectacular images revealed filigree structure and odd regional color variations, and exquisitely detailed radial profiles of fluctuating particle abundance were obtained from the first stellar and radio occultations, having resolution almost at the scale of single particles. Voyager-era understanding was reviewed by Cuzzi et al. (1984) and Esposito et al. (1984). While the Voyager data kept ring scientists busy for decades, planning which led to the monumentally successful NASA-ESA-ASI Cassini mission, which arrived in 2004, had been under way even before Voyager got to Saturn. A review of pre-Cassini knowledge of Saturn's Rings can be found in Orton et al. (2009). This chapter will build on recent topical and process-specific reviews that treat the gamut of ring phenomena and its underlying physics in considerable detail (Colwell et al., 2009; Cuzzi et al., 2009; Horányi et al., 2009; Schmidt et al., 2009; Esposito, 2010; Tiscareno, 2013b; Esposito, 2014). We will follow and extend the general organization of Cuzzi et al. (2010), the most recent general discussion of Saturn's rings. For brevity and the benefit of the

  20. BERKELEY: ALS ring

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-06-15

    Everybody at Lawrence Berkeley Laboratory's Center for Beam Physics is pleased with the rapid progress in commissioning LBL's Advanced Light Source (ALS) electron storage ring, the foundation for this third-generation synchrotron radiation facility. Designed for a maximum current of 400 mA, the ALS storage ring reached 407 mA just 24 days after storing the first beam on 16 March. ALS construction as a US Department of Energy (DOE) national user facility to provide high-brightness vacuum ultra-violet and soft x-ray radiation began in October 1987. One technical requirement marking project completion was to accumulate a 50-mA current in the storage ring. The ALS passed this milestone on 24 March, a week ahead of the official deadline. Once injected, the electron beam decays quasi-exponentially primarily because of interactions with residual gas molecules in the storage-ring vacuum chamber. Eventually, when the pressure in the vacuum chamber with beam decreases toward the expected operating level of 1 nano Torr, it will only be necessary to refill the storage ring at intervals of four to eight hours. At present the vacuum is improving rapidly as surfaces are irradiated (scrubbed) by the synchrotron radiation itself. At 100 mA, beam lifetime was about one hour (9 April)

  1. Compressible Vortex Ring

    Science.gov (United States)

    Elavarasan, Ramasamy; Arakeri, Jayawant; Krothapalli, Anjaneyulu

    1999-11-01

    The interaction of a high-speed vortex ring with a shock wave is one of the fundamental issues as it is a source of sound in supersonic jets. The complex flow field induced by the vortex alters the propagation of the shock wave greatly. In order to understand the process, a compressible vortex ring is studied in detail using Particle Image Velocimetry (PIV) and shadowgraphic techniques. The high-speed vortex ring is generated from a shock tube and the shock wave, which precedes the vortex, is reflected back by a plate and made to interact with the vortex. The shadowgraph images indicate that the reflected shock front is influenced by the non-uniform flow induced by the vortex and is decelerated while passing through the vortex. It appears that after the interaction the shock is "split" into two. The PIV measurements provided clear picture about the evolution of the vortex at different time interval. The centerline velocity traces show the maximum velocity to be around 350 m/s. The velocity field, unlike in incompressible rings, contains contributions from both the shock and the vortex ring. The velocity distribution across the vortex core, core diameter and circulation are also calculated from the PIV data.

  2. BERKELEY: ALS ring

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Everybody at Lawrence Berkeley Laboratory's Center for Beam Physics is pleased with the rapid progress in commissioning LBL's Advanced Light Source (ALS) electron storage ring, the foundation for this third-generation synchrotron radiation facility. Designed for a maximum current of 400 mA, the ALS storage ring reached 407 mA just 24 days after storing the first beam on 16 March. ALS construction as a US Department of Energy (DOE) national user facility to provide high-brightness vacuum ultra-violet and soft x-ray radiation began in October 1987. One technical requirement marking project completion was to accumulate a 50-mA current in the storage ring. The ALS passed this milestone on 24 March, a week ahead of the official deadline. Once injected, the electron beam decays quasi-exponentially primarily because of interactions with residual gas molecules in the storage-ring vacuum chamber. Eventually, when the pressure in the vacuum chamber with beam decreases toward the expected operating level of 1 nano Torr, it will only be necessary to refill the storage ring at intervals of four to eight hours. At present the vacuum is improving rapidly as surfaces are irradiated (scrubbed) by the synchrotron radiation itself. At 100 mA, beam lifetime was about one hour (9 April)

  3. Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Marat A. Aripov

    2017-04-01

    Full Text Available This report describes a 32 years old patient with Marfan syndrome and hypertension. David`s procedure was performed to the patient three months before due to dissection of the ascending thoracic aorta. Computer tomography scan showed DeBakey type III dissection of aorta beginning from left subclavian artery with transition to the ostium of the celiac trunk and proximal part of the left common iliac artery. Stent-grafts in the descending thoracic aorta with overlapping of left subclavian artery were implanted to the patient with Marfan syndrome. Patient was discharged and no complications recorded at 6th month follow-up.

  4. Valve-sparing root and ascending aorta replacement after heart transplantation.

    Science.gov (United States)

    Elhenawy, Abdelsalam M; Feindel, Christopher M; Ross, Heather; Butany, Jagdish; Yau, Terrence M

    2012-12-01

    A 45-year-old female underwent heart transplantation 17 years ago, with a heart from a 15-year-old donor. Recently, she had developed an aneurysm of the donor aortic root and ascending aorta, with severe aortic insufficiency. Two surgical options were considered; retransplantation versus replacement of the aortic root and ascending aorta. A valve-sparing replacement of the aortic root and ascending aortic aneurysm was performed. The donor aorta showed pathologic changes typical of Marfan syndrome. Nineteen months postoperatively, the patient remains in functional class I, with trivial aortic insufficiency. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Endothelium-Independent Vasorelaxant Effect of Ligusticum jeholense Root and Rhizoma on Rat Thoracic Aorta

    Directory of Open Access Journals (Sweden)

    Bumjung Kim

    2015-06-01

    Full Text Available Ligusticum jeholense has been used as the traditional medicine ‘Go-Bon’ (Chinese name, Gao-ben in China and Korea. Considering the increased use of medicinal herbs to treat hypertension, in this study, we aimed to investigate the mechanisms of the vasorelaxation effect caused by L. jeholense. We tested the methanol (MeOH extract of L. jeholense root and rhizoma for vasorelaxant effects; while using an isolated organ-chamber technique, L. jeholense extract (LJE induced relaxation in the rat aortic rings by stimulating vascular endothelial and smooth muscle cells. LJE showed concentration-dependent relaxant effects on endothelium-intact and endothelium-denuded aortic rings pre-contracted with both phenylephrine (PE and potassium chloride (KCl in Krebs-Henseleit (KH buffer. The vasorelaxant effect of LJE was partly attenuated by pre-treatment with glibenclamide or 4-aminopyridine (4-AP as K+ channel blockers. Moreover, LJE showed concentration-dependent inhibition of vasoconstriction by Ca2+ supplementation in the aortic rings that were pre-contracted with PE or KCl in Ca2+-free KH buffer. In addition, a combination of LJE and nifedipine, pre-incubated further, decreased PE-induced contractions. The results suggested that LJE-induced vasorelaxation were related to blocking K+ channels and inhibiting entry of extracellular Ca2+ via receptor-operative Ca2+ channels (ROCCs or voltage-dependent Ca2+ channels (VDCCs.

  6. Almost ring theory

    CERN Document Server

    2003-01-01

    This book develops thorough and complete foundations for the method of almost etale extensions, which is at the basis of Faltings' approach to p-adic Hodge theory. The central notion is that of an "almost ring". Almost rings are the commutative unitary monoids in a tensor category obtained as a quotient V-Mod/S of the category V-Mod of modules over a fixed ring V; the subcategory S consists of all modules annihilated by a fixed ideal m of V, satisfying certain natural conditions. The reader is assumed to be familiar with general categorical notions, some basic commutative algebra and some advanced homological algebra (derived categories, simplicial methods). Apart from these general prerequisites, the text is as self-contained as possible. One novel feature of the book - compared with Faltings' earlier treatment - is the systematic exploitation of the cotangent complex, especially for the study of deformations of almost algebras.

  7. Compact electron storage rings

    International Nuclear Information System (INIS)

    Williams, G.P.

    1987-01-01

    There have been many recent developments in the area of compact storage rings. Such rings would have critical wavelengths of typically 10 A, achieved with beam energies of several hundreds of MeV and superconducting dipole fields of around 5 Tesla. Although the primary motivation for progress in this area is that of commercial x-ray lithography, such sources might be an attractive source for college campuses to operate. They would be useful for many programs in materials science, solid state, x-ray microscopy and other biological areas. We discuss the properties of such sources and review developments around the world, primarily in the USA, japan and W. Germany

  8. The covariant chiral ring

    Energy Technology Data Exchange (ETDEWEB)

    Bourget, Antoine; Troost, Jan [Laboratoire de Physique Théorique, École Normale Supérieure, 24 rue Lhomond, 75005 Paris (France)

    2016-03-23

    We construct a covariant generating function for the spectrum of chiral primaries of symmetric orbifold conformal field theories with N=(4,4) supersymmetry in two dimensions. For seed target spaces K3 and T{sup 4}, the generating functions capture the SO(21) and SO(5) representation theoretic content of the chiral ring respectively. Via string dualities, we relate the transformation properties of the chiral ring under these isometries of the moduli space to the Lorentz covariance of perturbative string partition functions in flat space.

  9. Vortex and source rings

    DEFF Research Database (Denmark)

    Branlard, Emmanuel Simon Pierre

    2017-01-01

    The velocity field, vector potential and velocity gradient of a vortex ring is derived in this chapter. The Biot-Savart law for the vector potential and velocity is expressed in a first section. Then, the flow is derived at specific locations: on the axis, near the axis and in the far field where...... the analogy to a doublet field is made. The following section derive the value of the vector potential and velocity field in the full domain. The expression for the velocity gradient is also provided since it may be relevant in a simulation with vortex particles and vortex rings. Most of this chapter...

  10. The Saturnian rings

    International Nuclear Information System (INIS)

    Alfven, H.

    1975-09-01

    The structure of the Saturnian rings is traditionally believed to be due to resonances caused by Mimas (and possibly other satellites). It is shown that both theoretical and observational evidence rule out this interpretation. The increased observational accuracy on one hand and the increased understanding of the cosmogonic processes on the other makes it possible to explain the structure of the ring system as a product of condensation from a partially corotating plasma. In certain respects the agreement between theory and observations is about 1%. (Auth.)

  11. RINGED ACCRETION DISKS: INSTABILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, D.; Stuchlík, Z., E-mail: d.pugliese.physics@gmail.com, E-mail: zdenek.stuchlik@physics.cz [Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Faculty of Philosophy and Science, Silesian University in Opava, Bezručovo náměstí 13, CZ-74601 Opava (Czech Republic)

    2016-04-01

    We analyze the possibility that several instability points may be formed, due to the Paczyński mechanism of violation of mechanical equilibrium, in the orbiting matter around a supermassive Kerr black hole. We consider a recently proposed model of a ringed accretion disk, made up by several tori (rings) that can be corotating or counter-rotating relative to the Kerr attractor due to the history of the accretion process. Each torus is governed by the general relativistic hydrodynamic Boyer condition of equilibrium configurations of rotating perfect fluids. We prove that the number of the instability points is generally limited and depends on the dimensionless spin of the rotating attractor.

  12. Vascular dysfunctions in the isolated aorta of double-transgenic hypertensive mice developing aortic aneurysm

    DEFF Research Database (Denmark)

    Waeckel, L.; Badier-Commander, C.; Damery, T.

    2015-01-01

    Angiotensin-II and oxidative stress are involved in the genesis of aortic aneurysms, a phenomenon exacerbated by endothelial nitric oxide synthase (eNOS) deletion or uncoupling. The purpose of this work was to study the endothelial function in wild-type C57BL/6 (BL) and transgenic mice expressing...

  13. Uric acid does not affect the acetylcholine-induced relaxation of aorta from normotensive and deoxycorticosterone acetate-salt hypertensive rats.

    Science.gov (United States)

    Szasz, Theodora; Watts, Stephanie W

    2010-06-01

    Uric acid (UA) results from xanthine oxidase (XO) catabolism of xanthine and is the final product of purine catabolism in humans. In this species, hyperuricemia is associated with gout, nephropathy, and increased cardiovascular disease risk. Although the effects of hyperuricemia in vascular biology are overall controversial, UA has been described as an antioxidant and as potentially improving endothelial function. Hypertension is associated with endothelial dysfunction. We hypothesized that UA improves the endothelial function of aorta from deoxycorticosterone acetate (DOCA)-salt hypertensive rats. UA (100 microM) in the presence of the uricase inhibitor oxonic acid (10 microM) did not modify relaxation to acetylcholine (ACh) (1 nM-10 microM) in the aorta from nontreated, sham normotensive, and DOCA-salt hypertensive rats [response to 10 microM ACh for UA versus vehicle, respectively: nontreated = 37 +/- 7 versus 48 +/- 7%, sham = 53 +/- 15 versus 57 +/- 20%, DOCA = 81 +/- 4 versus 85 +/- 2% from 20 microM prostaglandin 2alpha (PGF(2alpha))-induced contraction]. Allopurinol (100 microM), a XO inhibitor, did not significantly alter the ACh-induced relaxation of sham and DOCA aortic rings (response to 10 microM ACh for allopurinol versus vehicle, respectively: sham = 61 +/- 5 versus 68 +/- 9%, DOCA = 87 +/- 6 versus 88 +/- 3% from 20 microM PGF(2alpha)-induced contraction). Uricemia, ranging from unmeasurable to 547 microM in sham and to 506 microM in DOCA rats, was not significantly different between these two groups. The expression and activity of XO, as well as the expression of uricase, were not different between sham and DOCA rat aorta. We conclude that, at least in vitro, UA does not affect the ACh-induced relaxation of normotensive and DOCA-salt hypertensive rats.

  14. Mural Thrombus in the Normal-Appearing Descending Thoracic Aorta of a Chronic Smoker

    Science.gov (United States)

    Habib, Habib; Hsu, Judy; Winchell, Patricia Jo; Daoko, Joseph

    2013-01-01

    Thrombus formation in an atherosclerotic or aneurysmal descending thoracic aorta is a well-described, frequently encountered vascular condition. In comparison, thrombus formation in a normal-appearing descending thoracic aorta is reported far less often. We describe the case of a 46-year-old woman who had splenic and renal infarctions secondary to embolic showers from a large, mobile thrombus in a morphologically normal proximal descending thoracic aorta. After the patient underwent anticoagulation, stent-grafting, and surgical bypass to correct an arterial blockage caused by the stent-graft, she resumed a relatively normal life. In contrast with other cases of a thrombotic but normal-appearing descending thoracic aorta, this patient had no known malignancy or systemic coagulative disorders; her sole risk factor was chronic smoking. We discuss our patient's case and review the relevant medical literature, focusing on the effect of smoking on coagulation physiology. PMID:24391341

  15. Upper gastrointestinal bleeding, aneurismatic dilatation of the thoracic aorta and filling defect on the esophagogram

    Energy Technology Data Exchange (ETDEWEB)

    Naschitz, J.E.; Bassan, H.; Lazarov, N.; Grishkan, A.

    1982-06-01

    A patient is described with an aneurysm of the thoracic aorta, which has ruptured into the esophagus. An esophageal X-ray contrast study has revealed a filling defect at the contact site of the esophagus and the aortic aneurysm. The filling defect was due to a clot protruding from the aorta into the esophagus. This unique case calls attention to a diagnostic triad: upper gastrointestinal bleeding, aneurysm of the thoracic aorta, and filling defect in the esophagus at its site of contact with the enlarged aorta. This triad suggested aortoesophageal fistula (AEF) in the patient and could help in the diagnosis of atypical cases of AEF, where thoracic aortography has not been performed initially.

  16. Anatomic radiological study of transverse diameter of abdominal aorta by computerized tomography

    International Nuclear Information System (INIS)

    Ures, S.

    1984-01-01

    The transverse diameter of abdominal aorta by computerized tomography is studied. The purpose is establish the frequent standard diameters and then diagnose early pathologies, mainly aneurisms. (M.A.C.) [pt

  17. Upper gastrointestinal bleeding, aneurismatic dilatation of the thoracic aorta and filling defect on the esophagogram

    International Nuclear Information System (INIS)

    Naschitz, J.E.; Bassan, H.; Lazarov, N.; Grishkan, A.; Haifa Univ.; Haifa Univ.

    1982-01-01

    A patient is described with an aneurysm of the thoracic aorta, which has ruptured into the esophagus. An esophageal X-ray contrast study has revealed a filling defect at the contact site of the esophagus and the aortic aneurysm. The filling defect was due to a clot protruding from the aorta into the esophagus. This unique case calls attention to a diagnostic triad: upper gastrointestinal bleeding, aneurysm of the thoracic aorta, and filling defect in the esophagus at its site of contact with the enlarged aorta. This triad suggested aortoesophageal fistula (AEF) in the patient and could help in the diagnosis of atypical cases of AEF, where thoracic aortography has not been performed initially. (orig.) [de

  18. Dynamic renal scintigraphy of dissecting aneurysm of abdominal aorta

    International Nuclear Information System (INIS)

    Tsukamoto, Eriko; Itoh, Kazuo; Furudate, Masayori

    1990-01-01

    Dynamic renal scintigraphy on 15 patients with dissecting aneurysm of abdominal aorta extending below the renal arteries were retrospectively studied. The results were reviewed and classified into 3 types according to perfusion images and parenchymal tissue uptake: Type A--symmetric perfusion and parenchymal tissue uptake; Type B--asymmetrical perfusion and parenchymal tissue uptake; Type C--delayed perfusion of one kidney and symmetric parenchymal tissue uptake. The number of patients who showed Type A, Type B, and Type C were 3 cases, 6 cases, and 6 cases, respectively. In all Type A and 3 of Type B, perfusion of bilateral renal arteries was mainly from true lumen. In the remaining 3 cases of Type B, 2 had one renal artery obstructed with thrombus; 1 had a deformity of one kidney (the blood supply was mainly from a false lumen), suggestive of renal infarction. On the other hand, in all 6 Type C cases, the renal artery where perfusion was delayed was apparently supplied from false lumen. It is suggested in this retrospective study that the findings in Type C, where delayed perfusion of one kidney and symmetric parenchymal tissue uptake were found, were due to the presence of delayed flow through the false lumen; and therefore, specific to cases where the main blood supply of one renal artery from false lumen. (author)

  19. Phosphoinositide metabolism and metabolism-contraction coupling in rabbit aorta

    International Nuclear Information System (INIS)

    Coburn, R.F.; Baron, C.; Papadopoulos, M.T.

    1988-01-01

    The authors tested a hypothesis that metabolism-contraction coupling in vascular smooth muscle is controlled by the rate of delivery of energy to ATP-dependent reactions in the inositol phospholipid transduction system that generate second messengers exerting control on smooth muscle force. Rabbit aorta was contracted by norepinephrine (NOR) under conditions of normoxia and hypoxia, and changes in inositol phospholipid pool sizes and metabolic flux rates (J F ) were determined. J F was determined by labeling free cytosolic myo-inositol by incubation of unstimulated muscle with myo-[ 3 H]inositol and then measuring rates of incorporation of this isotope into inositol phospholipids and inositol phosphates when the muscle was activated by NOR. J F measured during maintenance of NOR-induced force was markedly inhibited during hypoxia to 40-50% of that determined during normoxia; rates of increases in inositol phosphate radioactivities were similarly depressed during NOR activation under hypoxia. The hypoxia-induced decrease in J F was associated with four- to fivefold increase in phosphatidylinositol 4-phosphate (PIP) total pool size, suggesting PIP kinase was inhibited and rate limiting. These data suggest that activation of inositol phospholipid metabolism, which generates inositol 1,4,5-trisphosphate (IP 3 ) and diacylglycerol, is blunted under conditions where aerobic energy production is inhibited. Data are consistent with rate-limiting effects of decreased ATP delivery, or decreased phosphate potential, on PIP kinase and reactions that control resynthesis of phosphatidylinositol

  20. Role of CT for dissecting aneurysm of aorta

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup [College of Medicine, Hallym University, Chunchun (Korea, Republic of)

    1987-06-15

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation.

  1. Role of CT for dissecting aneurysm of aorta

    International Nuclear Information System (INIS)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup

    1987-01-01

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation

  2. Fusion rings and fusion ideals

    DEFF Research Database (Denmark)

    Andersen, Troels Bak

    by the so-called fusion ideals. The fusion rings of Wess-Zumino-Witten models have been widely studied and are well understood in terms of precise combinatorial descriptions and explicit generating sets of the fusion ideals. They also appear in another, more general, setting via tilting modules for quantum......This dissertation investigates fusion rings, which are Grothendieck groups of rigid, monoidal, semisimple, abelian categories. Special interest is in rational fusion rings, i.e., fusion rings which admit a finite basis, for as commutative rings they may be presented as quotients of polynomial rings...

  3. Intramural hemorrhage of the thoracic aorta - imaging features and differential diagnosis; Das intramurale Haematom der thorakalen Aorta: Bildgebende Diagnostik und Differentialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T. [Bonn Univ. (Germany) Radiologische Klinik; Abu-Ramadan, D. [Bonn Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Busch, M. [Bonn Univ. (Germany) Radiologische Klinik; Bierhoff, E. [Bonn Univ. (Germany). Pathologische Inst.; Kreft, B. [Bonn Univ. (Germany) Radiologische Klinik; Kuhl, C. [Bonn Univ. (Germany) Radiologische Klinik; Lutterbey, G. [Bonn Univ. (Germany) Radiologische Klinik; Keller, E. [Bonn Univ. (Germany) Radiologische Klinik; Schild, H. [Bonn Univ. (Germany) Radiologische Klinik

    1996-09-01

    Purpose: Aortic wall thickening due to intramural hemorrhage may be the only sign of aortic dissection. The aim of this study was to evaluate the incidence, imaging features and differential diagnoses of intramural hemorrhage (IMH) of the thoracic aorta. Methods: 98 patients with clinically suspected aortic dissection were investigated via Spiral-CT and MRT. Diagnosis of IMH based on the presence of smooth crescentic or concentric wall thickening over a longer segment of the thoracic aorta without flow visualization and without compression or distortion of the aortic lumen. Results: 69 patients had classic aortic dissections and 7 patients were diagnosed to have IMH of the thoracic aorta. One patient with IMH of the ascending aorta died of aortic rupture and subsequent pericardial tamponade 12 hours after onset of symptoms. In one patient with IMH of the descending aorta on initial examination, there was a progression of overt aortic dissection at follow-up after three weeks. In two patients with IMH of the descending aorta, wall thickening decreased in size at follow-up (10-15 weeks), whereas in one patient it remained unchanged. Conclusion: IMH of the aorta should be considered a precursor of aortic dissection. At follow-up IMH may decrease in size, rupture or progress to overt aortic dissection. (orig.) [Deutsch] Ziel: Eine aortale Wandverdichtung als Ausdruck eines intramuralen Haematoms kann die einzige Manifestation einer Aortendissektion sein. Ziel dieser Arbeit war die Evaluierung der Inzidenz, bildgebenden Aspekte und Differentialdiagnosen dieses in der deutschsprachigen Literatur wenig bekannten Krankheitsbildes. Methode: 98 Patienten mit klinischem Verdacht auf eine Aortendissektion wurden MR- und computertomographisch untersucht. Kriterium fuer das Vorliegen eines intramuralen Haematoms war der Nachweis einer laengerstreckigen aortalen Wandverdickung ohne Flussnachweis sowie ohne Konfigurationsaenderung des aortalen Lumens. Ergebnisse: 69 Patienten

  4. Flushing Ring for EDM

    Science.gov (United States)

    Earwood, L.

    1985-01-01

    Removing debris more quickly lowers cutting time. Operation, cutting oil and pressurized air supplied to ring placed around workpiece. Air forces oil through small holes and agitates oil as it flows over workpiece. High flow rate and agitation dislodge and remove debris. Electrical discharge removes material from workpiece faster.

  5. Sector ring accelerator ''RESATRON''

    International Nuclear Information System (INIS)

    Schwabe, E.

    1980-01-01

    Project of sector ring accelerator RESATRON is described. The curiosity of this accelerator is the second cycle of acceleration of the beam after stripping it on the foil. In such an accelerator heavy ions with a different ratio Z to A can be accelerated. (S.B.)

  6. Ring chromosome 13

    DEFF Research Database (Denmark)

    Brandt, C A; Hertz, Jens Michael; Petersen, M B

    1992-01-01

    A stillborn male child with anencephaly and multiple malformations was found to have the karyotype 46,XY,r(13) (p11q21.1). The breakpoint at 13q21.1, determined by high resolution banding, is the most proximal breakpoint ever reported in patients with ring chromosome 13. In situ hybridisation...

  7. SXLS storage ring design

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    X-ray lithography has emerged as a strong candidate to meet the demands of ever finer linewidths on integrated circuits, particularly for linewidths less than .25 microns. Proximity printing X-ray lithography makes use of soft X-rays to shadow print an image of a mask onto a semiconductor wafer to produce integrated circuits. To generate the required X-rays in sufficient quantities to make commercial production viable, electron storage rings have been proposed as the soft X-ray sources. Existing storage rings have been used to do the initial development work and the success of these efforts has led the lithographers to request that new rings be constructed that are dedicated to X-ray lithography. As a result of a series of workshops held at BNL [10.3] which were attended by both semiconductor and accelerator scientists, the following set of zeroth order specifications' on the light and electron beam of a storage ring for X-ray lithography were developed: critical wavelength of light: λ c = 6 to 10 angstroms, white light power: P = 0.25 to 2.5 watts/mrad, horizontal collection angle per port: θ = 10 to 50 mrad, electron beam sizes: σ x ∼ σ y y ' < 1 mrad

  8. Ring magnetron ionizer

    International Nuclear Information System (INIS)

    Alessi, J.G.

    1986-01-01

    A ring magnetron D - charge exchange ionizer has been built and tested. An H - current of 500 μA was extracted with an estimated H 0 density in the ionizer of 10 12 cm -3 . This exceeds the performance of ionizers presently in use on polarized H - sources. The ionizer will soon be tested with a polarized atomic beam

  9. Algebras, rings and modules

    CERN Document Server

    Hazewinkel, Michiel; Kirichenko, V V

    Provides both the classical aspects of the theory of groups and their representations as well as a general introduction to the modern theory of representations, including the representations of quivers and finite partially ordered sets. This volume provides the theory of semiprime Noetherian semiperfect and semidistributive rings.

  10. Lattices for antiproton rings

    International Nuclear Information System (INIS)

    Autin, B.

    1984-01-01

    After a description of the constraints imposed by the cooling of Antiprotons on the lattice of the rings, the reasons which motivate the shape and the structure of these machines are surveyed. Linear and non-linear beam optics properties are treated with a special amplification to the Antiproton Accumulator. (orig.)

  11. Ruptured Sinus of Valsalva Aneurysm and Coarctation of Aorta in a Woman at Early Postpartum Period

    Directory of Open Access Journals (Sweden)

    Erol Sener

    2014-01-01

    Full Text Available Coarctation of aorta and sinus of Valsalva aneurysm are frequently missed congenital cardiac defects that their diagnosis might be delayed. To our knowledge, coincidence of these cardiac defects is unusual and has not been reported in the literature before. Here, we present a patient with coarctation of aorta and ruptured noncoronary sinus of Valsalva aneurysm leading to aorto-right atrial fistula in the early postpartum period and our management of this unusual case.

  12. Propellers in Saturn's rings

    Science.gov (United States)

    Sremcevic, M.; Stewart, G. R.; Albers, N.; Esposito, L. W.

    2013-12-01

    Theoretical studies and simulations have demonstrated the effects caused by objects embedded in planetary rings. Even if the objects are too small to be directly observed, each creates a much larger gravitational imprint on the surrounding ring material. These strongly depend on the mass of the object and range from "S" like propeller-shaped structures for about 100m-sized icy bodies to the opening of circumferential gaps as in the case of the embedded moons Pan and Daphnis and their corresponding Encke and Keeler Gaps. Since the beginning of the Cassini mission many of these smaller objects (~data from Cassini Ultraviolet Imaging Spectrograph (UVIS) and Imaging Science Subsystem (ISS) experiments. We show evidence that B ring seems to harbor two distinct populations of propellers: "big" propellers covering tens of degrees in azimuth situated in the densest part of B ring, and "small" propellers in less dense inner B ring that are similar in size and shape to known A ring propellers. The population of "big" propellers is exemplified with a single object which is observed for 5 years of Cassini data. The object is seen as a very elongated bright stripe (40 degrees wide) in unlit Cassini images, and dark stripe in lit geometries. In total we report observing the feature in images at 18 different epochs between 2005 and 2010. In UVIS occultations we observe this feature as an optical depth depletion in 14 out of 93 occultation cuts at corrotating longitudes compatible with imaging data. Combining the available Cassini data we infer that the object is a partial gap located at r=112,921km embedded in the high optical depth region of the B ring. The gap moves at Kepler speed appropriate for its radial location. Radial offsets of the gap locations in UVIS occultations are consistent with an asymmetric propeller shape. The asymmetry of the observed shape is most likely a consequence of the strong surface mass density gradient, as the feature is located at an edge between

  13. Hybrid Approach of Aortic Diseases: Zone 1 Delivery and Volumetric Analysis on the Descending Aorta

    Directory of Open Access Journals (Sweden)

    José Augusto Duncan

    Full Text Available Abstract Introduction: Conventional techniques of surgical correction of arch and descending aortic diseases remains as high-risk procedures. Endovascular treatments of abdominal and descending thoracic aorta have lower surgical risk. Evolution of both techniques - open debranching of the arch and endovascular approach of the descending aorta - may extend a less invasive endovascular treatment for a more extensive disease with necessity of proximal landing zone in the arch. Objective: To evaluate descending thoracic aortic remodeling by means of volumetric analysis after hybrid approach of aortic arch debranching and stenting the descending aorta. Methods: Retrospective review of seven consecutive patients treated between September 2014 and August 2016 for diseases of proximal descending aorta (aneurysms and dissections by hybrid approach to deliver the endograft at zone 1. Computed tomography angiography were analyzed using a specific software to calculate descending thoracic aorta volumes pre- and postoperatively. Results: Follow-up was done in 100% of patients with a median time of 321 days (range, 41-625 days. No deaths or permanent neurological complications were observed. There were no endoleaks or stent migrations. Freedom from reintervention was 100% at 300 days and 66% at 600 days. Median volume reduction was of 45.5 cm3, representing a median volume shrinkage by 9.3%. Conclusion: Hybrid approach of arch and descending thoracic aorta diseases is feasible and leads to a favorable aortic remodeling with significant volume reduction.

  14. The value of anterior displacement of the abdominal aorta in diagnosing neuroblastoma in children

    Energy Technology Data Exchange (ETDEWEB)

    Schiavon, Jose Luiz de Oliveira; Caran, Eliana Maria Monteiro; Lederman, Henrique Manoel, E-mail: schiavon00@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Odone Filho, Vicente [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina

    2016-11-15

    Objective: To determine the value of anterior displacement of the abdominal aorta, when present at any level or only at the level of the adrenal gland, contralateral to the mass, in diagnosing neuroblastoma on computed tomography or magnetic resonance imaging in children up to 7 years of age. Materials and Methods: Imaging examinations of 66 patients were classified by consensus as for the presence of anterior aorta displacement and were compared with the pathology report. Results: We found anterior abdominal aorta displacement in 26 (39.39%) of the 66 patients evaluated. Among those 26 patients, we identified neuroblastoma in 22 (84.62%), nephroblastoma in 3 (11.54%), and Burkitt lymphoma in 1 (3.85%). The positive predictive value was 84.62%, and the specificity was 88.24%. The displacement of the aorta was at the adrenal level, contralateral to the mass, in 14 cases, all of which were attributed to neuroblastoma. Conclusion: When the abdominal aorta is displaced at the level of the adrenal gland, contralateral to the mass, it can be said that the diagnosis is neuroblastoma, whereas abdominal aorta displacement occurring at other abdominal levels has a positive predictive value for neuroblastoma of approximately 85%. (author)

  15. The value of anterior displacement of the abdominal aorta in diagnosing neuroblastoma in children

    International Nuclear Information System (INIS)

    Schiavon, Jose Luiz de Oliveira; Caran, Eliana Maria Monteiro; Lederman, Henrique Manoel; Odone Filho, Vicente

    2016-01-01

    Objective: To determine the value of anterior displacement of the abdominal aorta, when present at any level or only at the level of the adrenal gland, contralateral to the mass, in diagnosing neuroblastoma on computed tomography or magnetic resonance imaging in children up to 7 years of age. Materials and Methods: Imaging examinations of 66 patients were classified by consensus as for the presence of anterior aorta displacement and were compared with the pathology report. Results: We found anterior abdominal aorta displacement in 26 (39.39%) of the 66 patients evaluated. Among those 26 patients, we identified neuroblastoma in 22 (84.62%), nephroblastoma in 3 (11.54%), and Burkitt lymphoma in 1 (3.85%). The positive predictive value was 84.62%, and the specificity was 88.24%. The displacement of the aorta was at the adrenal level, contralateral to the mass, in 14 cases, all of which were attributed to neuroblastoma. Conclusion: When the abdominal aorta is displaced at the level of the adrenal gland, contralateral to the mass, it can be said that the diagnosis is neuroblastoma, whereas abdominal aorta displacement occurring at other abdominal levels has a positive predictive value for neuroblastoma of approximately 85%. (author)

  16. Feasibility of low contrast media volume in CT angiography of the aorta

    International Nuclear Information System (INIS)

    Seehofnerová, Anna; Kok, Madeleine; Mihl, Casper; Douwes, Dave; Sailer, Anni; Nijssen, Estelle; Haan, Michiel J.W. de; Wildberger, Joachim E.; Das, Marco

    2015-01-01

    Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. 77 patients referred for CTA of the aorta were scanned using a standard MDCT protocol at 100 kV. A bolus of 50 ml CM (Iopromide 300 mg Iodine/ml) at a flow rate of 6 ml/s was applied (Iodine delivery rate IDR = 1.8 g/s; Iodine load 15 g) followed by a saline bolus of 40 ml at the same flow rate. Scan delay was determined by the test bolus method. Subjective image quality was assessed and contrast enhancement was measured at 10 anatomical levels of the aorta. Diagnostic quality images were obtained for all patients, reaching a mean overall contrast enhancement of 324 ± 28 HU. Mean attenuation was 350 ± 60 HU at the thoracic aorta and 315 ± 83 HU at the abdominal aorta. A straightforward low volume CM protocol proved to be technically feasible and led to CTA examinations reaching diagnostic image quality of the aorta at 100 kV. Based on these findings, the use of a relatively small CM bolus can be incorporated into routine clinical imaging

  17. Evaluation of reconstruction parameters of electrical impedance tomography on aorta detection during saline bolus injection

    Directory of Open Access Journals (Sweden)

    Thürk Florian

    2016-09-01

    Full Text Available An accurate detection of anatomical structures in electrical impedance tomography (EIT is still at an early stage. Aorta detection in EIT is of special interest, since it would favor non-invasive assessment of hemodynamic processes in the body. Here, diverse EIT reconstruction parameters of the GREIT algorithm were systematically evaluated to detect the aorta after saline bolus injection in apnea. True aorta position and size were taken from computed tomography (CT. A comparison with CT showed that the smallest error for aorta displacement was attained for noise figure nf = 0.7, weighting radius rw = 0.15, and target size ts = 0.01. The spatial extension of the aorta was most precise for nf = 0.7, rw = 0.25, and ts = 0.07. Detection accuracy (F1-score was highest with nf = 0.6, rw = 0.15, and ts = 0.04. This work provides algorithm-related evidence for potentially accurate aorta detection in EIT after injection of a saline bolus.

  18. FUZZY RINGS AND ITS PROPERTIES

    Directory of Open Access Journals (Sweden)

    Karyati Karyati

    2017-01-01

      One of algebraic structure that involves a binary operation is a group that is defined  an un empty set (classical with an associative binary operation, it has identity elements and each element has an inverse. In the structure of the group known as the term subgroup, normal subgroup, subgroup and factor group homomorphism and its properties. Classical algebraic structure is developed to algebraic structure fuzzy by the researchers as an example semi group fuzzy and fuzzy group after fuzzy sets is introduced by L. A. Zadeh at 1965. It is inspired of writing about semi group fuzzy and group of fuzzy, a research on the algebraic structure of the ring is held with reviewing ring fuzzy, ideal ring fuzzy, homomorphism ring fuzzy and quotient ring fuzzy with its properties. The results of this study are obtained fuzzy properties of the ring, ring ideal properties fuzzy, properties of fuzzy ring homomorphism and properties of fuzzy quotient ring by utilizing a subset of a subset level  and strong level  as well as image and pre-image homomorphism fuzzy ring.   Keywords: fuzzy ring, subset level, homomorphism fuzzy ring, fuzzy quotient ring

  19. Inorganic glass ceramic slip rings

    Science.gov (United States)

    Glossbrenner, E. W.; Cole, S. R.

    1972-01-01

    Prototypes of slip rings have been fabricated from ceramic glass, a material which is highly resistant to deterioration due to high temperature. Slip ring assemblies were not structurally damaged by mechanical tests and performed statisfactorily for 200 hours.

  20. Uniquely Strongly Clean Group Rings

    Institute of Scientific and Technical Information of China (English)

    WANG XIU-LAN

    2012-01-01

    A ring R is called clean if every element is the sum of an idempotent and a unit,and R is called uniquely strongly clean (USC for short) if every element is uniquely the sum of an idempotent and a unit that commute.In this article,some conditions on a ring R and a group G such that RG is clean are given.It is also shown that if G is a locally finite group,then the group ring RG is USC if and only if R is USC,and G is a 2-group.The left uniquely exchange group ring,as a middle ring of the uniquely clean ring and the USC ring,does not possess this property,and so does the uniquely exchange group ring.

  1. Ring closure in actin polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Supurna, E-mail: supurna@rri.res.in [Raman Research Institute, Bangalore 560080 (India); Chattopadhyay, Sebanti [Doon University, Dehradun 248001 (India)

    2017-03-18

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments. We also discuss the effect of ring closure on bend angle fluctuations in actin polymers. - Highlights: • Ring closure of biopolymers. • Worm like chain model. • Predictions for experiments.

  2. Design of low energy ring(s)

    CERN Document Server

    Lachaize, Antoine

    During the last two years, several upgrades of the initial baseline scenario were studied with the aim of increasing the average intensity of ion beams in the accelerator chain of the Beta Beam complex. This is the reason why the Rapid Cycling Synchrotron (RCS) specifications were reconsidered many times [1], [2], [3].General considerations on the optical design were presented at the Beta Beam Task Meetings held at CERN and at Saclay in 2005 [4]. More detailed beam optics studies were performed during the next months. Lattices, RF system parameters, multi-turn injection scheme, fast extraction, closed orbit correction and chromaticity correction systems were proposed for different versions of the RCS [5], [6], [7].Finally, the RCS specifications have stabilized in November 2006 after the fourth Beta Beam Task Meeting when it was decided to fix the maximum magnetic rigidity of ion beams to 14.47 T.m (3.5 GeV equivalent proton energy) and to adopt a ring physical radius of 40 m in order to facilitate injectio...

  3. L-arginine and Arginase Products Potentiate Dexmedetomidine-induced Contractions in the Rat Aorta.

    Science.gov (United States)

    Wong, Emily S W; Man, Ricky Y K; Ng, Kwok F J; Leung, Susan W S; Vanhoutte, Paul M

    2018-03-01

    The α2-adrenergic sedative/anesthetic agent dexmedetomidine exerts biphasic effects on isolated arteries, causing endothelium-dependent relaxations at concentrations at or below 30 nM, followed by contractions at higher concentrations. L-arginine is a common substrate of endothelial nitric oxide synthase and arginases. This study was designed to investigate the role of L-arginine in modulating the overall vascular response to dexmedetomidine. Isometric tension was measured in isolated aortic rings of Sprague Dawley rats. Cumulative concentrations of dexmedetomidine (10 nM to 10 μM) were added to quiescent rings (with and without endothelium) after previous incubation with vehicle, N-nitro-L-arginine methyl ester hydrochloride (L-NAME; nitric oxide synthase inhibitor), prazosin (α1-adrenergic antagonist), rauwolscine (α2-adrenergic antagonist), L-arginine, (S)-(2-boronethyl)-L-cysteine hydrochloride (arginase inhibitor), N-hydroxy-L-arginine (arginase inhibitor), urea and/or ornithine. In some preparations, immunofluorescent staining, immunoblotting, or measurement of urea content were performed. Dexmedetomidine did not contract control rings with endothelium but evoked concentration-dependent increases in tension in such rings treated with L-NAME (Emax 50 ± 4%) or after endothelium-removal (Emax 74 ± 5%; N = 7 to 12). Exogenous L-arginine augmented the dexmedetomidine-induced contractions in the presence of L-NAME (Emax 75 ± 3%). This potentiation was abolished by (S)-(2-boronethyl)-L-cysteine hydrochloride (Emax 16 ± 4%) and N-hydroxy-L-arginine (Emax 18 ± 4%). Either urea or ornithine, the downstream arginase products, had a similar potentiating effect as L-arginine. Immunoassay measurements demonstrated an upregulation of arginase I by L-arginine treatment in the presence of L-NAME (N = 4). These results suggest that when vascular nitric oxide homeostasis is impaired, the potentiation of the vasoconstrictor effect of

  4. Fusion Rings for Quantum Groups

    DEFF Research Database (Denmark)

    Andersen, Henning Haahr; Stroppel, Catharina

    2012-01-01

    We study the fusion rings of tilting modules for a quantum group at a root of unity modulo the tensor ideal of negligible tilting modules. We identify them in type A with the combinatorial rings from [12] and give a similar description of the sp2n-fusion ring in terms of noncommutative symmetric...

  5. RINGED ACCRETION DISKS: EQUILIBRIUM CONFIGURATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, D.; Stuchlík, Z., E-mail: d.pugliese.physics@gmail.com, E-mail: zdenek.stuchlik@physics.cz [Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Faculty of Philosophy and Science, Silesian University in Opava, Bezručovo náměstí 13, CZ-74601 Opava (Czech Republic)

    2015-12-15

    We investigate a model of a ringed accretion disk, made up by several rings rotating around a supermassive Kerr black hole attractor. Each toroid of the ringed disk is governed by the general relativity hydrodynamic Boyer condition of equilibrium configurations of rotating perfect fluids. Properties of the tori can then be determined by an appropriately defined effective potential reflecting the background Kerr geometry and the centrifugal effects. The ringed disks could be created in various regimes during the evolution of matter configurations around supermassive black holes. Therefore, both corotating and counterrotating rings have to be considered as being a constituent of the ringed disk. We provide constraints on the model parameters for the existence and stability of various ringed configurations and discuss occurrence of accretion onto the Kerr black hole and possible launching of jets from the ringed disk. We demonstrate that various ringed disks can be characterized by a maximum number of rings. We present also a perturbation analysis based on evolution of the oscillating components of the ringed disk. The dynamics of the unstable phases of the ringed disk evolution seems to be promising in relation to high-energy phenomena demonstrated in active galactic nuclei.

  6. Angiographic anatomy of major branches of the abdominal aorta

    International Nuclear Information System (INIS)

    Kim, K. W.; Suh, J. H.; Park, C. Y.

    1980-01-01

    These paper is an analyses of 110 patients who received abdominal aortography and selective organ angiography from July 1977 to August 1979 at the Department of Radiology of Yonsei Medical Center. 1. The most frequent site of bifurcation of the abdominal aorta was the 4th intervertebral disc level, occurring in 22 of 50 cases (42.3%). 2. The celiac trunk arose most frequently at the level of the 12th thoracic intervertebral disc, occurring in 11 of 52 cases (21.2%). 3. The superior mesenteric artery arose most frequent at the level of the upper third of the 1st lumbar vertebra, occurring in 8 of 30 cases (26.7%). 4. The right renal artery most frequently arose at the level of the middle third of the 1st lumbar vertebra, occurring in 17 of 70 cases (24.3%) and the left renal artery occurred most frequently in 1st lumbar vertebral disc level, 14 of 70 cases (20%). 5. Both renal arteries most commonly arose symmetrically as seen in 37 of 70 cases (52.6%). Case in which the rights arose at a higher level than the left occurred in 28 of 70 cases (40.6%). 6. Accessory renal arteries occurred in 19 of 70 cases (27.1%). 7. The most common form of the celiac trunk in which it divides into left gastric, splenic and common hepatic arteries was seen in 30 of 38 cases (78.9%). 8. The normal hepatic artery pattern in which it arise from the common hepatic artery and divides into right, middle and left hepatic artery occurred in 23 of 38 cases (60.5%0. A replaced right hepatic artery was seen in 2 of 35 cases (5.3%), and an accessory right hepatic artery also in 2 of 38 cases (5.3%).

  7. Vasorelaxant Effect of a Newly Synthesized Dihydropyridine Ethyl Ester (DHPEE on Rat Thoracic Aorta: Dual Mechanism of Action

    Directory of Open Access Journals (Sweden)

    Hossein Babaei

    2011-06-01

    Full Text Available Introduction: DHPEE is a newly synthesized compound by merging the key structural elements in an angiotensin receptor blocker (Telmisartan with key structural elements in 1,4- dihydropyridine calcium channel blocker (Nifedipine. In this study, we examined dual calcium channel blocking and AT1 antagonist activity for DHPEE. Methods: The functional inhibitory characteristics of DHPEE were studied in vitro in rat thoracic aorta preparations precontracted by phenylephrine (1µM or KCl (80µM or Ang II in normal or calcium-free solutions. Results: Concentration–dependent significant relaxation was observed in aortic rings precontracted with phenylephrine, KCl or Ang II. The tension increment produced by increasing external calcium was also reduced by DHPEE. DHPEE caused a marked decrease in the maximal contractile response of the vasoactive agents and shifted their concentration-response curves to the right. Conclusion: DHPEE possesses dual characteristics and cause vasorelaxation by blocking the L-type calcium channels and blocking Ang II receptors (AT1 in rat aortic smooth muscle.

  8. Modulatory Effect of 2-(4-Hydroxyphenylamino-1,4-naphthoquinone on Endothelial Vasodilation in Rat Aorta

    Directory of Open Access Journals (Sweden)

    Javier Palacios

    2016-01-01

    Full Text Available The vascular endothelium plays an essential role in the control of the blood flow. Pharmacological agents like quinone (menadione at various doses modulate this process in a variety of ways. In this study, Q7, a 2-phenylamino-1,4-naphthoquinone derivative, significantly increased oxidative stress and induced vascular dysfunction at concentrations that were not cytotoxic to endothelial or vascular smooth muscle cells. Q7 reduced nitric oxide (NO levels and endothelial vasodilation to acetylcholine in rat aorta. It also blunted the calcium release from intracellular stores by increasing the phenylephrine-induced vasoconstriction when CaCl2 was added to a calcium-free medium but did not affect the influx of calcium from extracellular space. Q7 increased the vasoconstriction to BaCl2 (10−3 M, an inward rectifying K+ channels blocker, and blocked the vasodilation to KCl (10−2 M in aortic rings precontracted with BaCl2. This was recovered with sodium nitroprusside (10−8 M, a NO donor. In conclusion, Q7 induced vasoconstriction was through a modulation of cellular mechanisms involving calcium fluxes through K+ channels, and oxidative stress induced endothelium damage. These findings contribute to the characterization of new quinone derivatives with low cytotoxicity able to pharmacologically modulate vasodilation.

  9. Modulatory Effect of 2-(4-Hydroxyphenyl)amino-1,4-naphthoquinone on Endothelial Vasodilation in Rat Aorta.

    Science.gov (United States)

    Palacios, Javier; Cifuentes, Fredi; Valderrama, Jaime A; Benites, Julio; Ríos, David; González, Constanza; Chiong, Mario; Cartes-Saavedra, Benjamín; Lafourcade, Carlos; Wyneken, Ursula; González, Pamela; Owen, Gareth I; Pardo, Fabián; Sobrevia, Luis; Buc Calderon, Pedro

    The vascular endothelium plays an essential role in the control of the blood flow. Pharmacological agents like quinone (menadione) at various doses modulate this process in a variety of ways. In this study, Q7 , a 2-phenylamino-1,4-naphthoquinone derivative, significantly increased oxidative stress and induced vascular dysfunction at concentrations that were not cytotoxic to endothelial or vascular smooth muscle cells. Q7 reduced nitric oxide (NO) levels and endothelial vasodilation to acetylcholine in rat aorta. It also blunted the calcium release from intracellular stores by increasing the phenylephrine-induced vasoconstriction when CaCl 2 was added to a calcium-free medium but did not affect the influx of calcium from extracellular space. Q7 increased the vasoconstriction to BaCl 2 (10 -3  M), an inward rectifying K + channels blocker, and blocked the vasodilation to KCl (10 -2  M) in aortic rings precontracted with BaCl 2 . This was recovered with sodium nitroprusside (10 -8  M), a NO donor. In conclusion, Q7 induced vasoconstriction was through a modulation of cellular mechanisms involving calcium fluxes through K + channels, and oxidative stress induced endothelium damage. These findings contribute to the characterization of new quinone derivatives with low cytotoxicity able to pharmacologically modulate vasodilation.

  10. Ring Confidential Transactions

    Directory of Open Access Journals (Sweden)

    Shen Noether

    2016-12-01

    Full Text Available This article introduces a method of hiding transaction amounts in the strongly decentralized anonymous cryptocurrency Monero. Similar to Bitcoin, Monero is a cryptocurrency which is distributed through a proof-of-work “mining” process having no central party or trusted setup. The original Monero protocol was based on CryptoNote, which uses ring signatures and one-time keys to hide the destination and origin of transactions. Recently the technique of using a commitment scheme to hide the amount of a transaction has been discussed and implemented by Bitcoin Core developer Gregory Maxwell. In this article, a new type of ring signature, A Multilayered Linkable Spontaneous Anonymous Group signature is described which allows one to include a Pedersen Commitment in a ring signature. This construction results in a digital currency with hidden amounts, origins and destinations of transactions with reasonable efficiency and verifiable, trustless coin generation. The author would like to note that early drafts of this were publicized in the Monero Community and on the #bitcoin-wizards IRC channel. Blockchain hashed drafts are available showing that this work was started in Summer 2015, and completed in early October 2015. An eprint is also available at http://eprint.iacr.org/2015/1098.

  11. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  12. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  13. Abdominal aorta coarctation: The first three case reports in our literature

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2010-01-01

    Full Text Available Introduction. Congenital coarctation of the thoracic aorta at the ligamentum arteriosum or the aortic arch is well recognized. But a much less common variety (0.5-2.0% of aortic coarctation is located in the distal thoracic aorta or abdominal aorta or both and is often called 'middle aortic syndrome' or 'midaortic dysplastic syndrome'. This represents serious pathological condition and indicates multidisciplinary therapy approach. Outline of Cases. From 1996 to 2007, at the Vascular Surgery Clinic of the Institute for Cardiovascular Diseases 'Dedinje', Belgrade, three patients were treated due to abdominal aorta coarctation, two females aged 55 and 50 and a 4-year-old child. The patients were treated surgically (by-pass with a prosthetic graft and patch angioplasty and endovascular-percutaneous transluminal angioplasty (PTA with and without a stent. The follow-up period was 3-70 months. In the 50-year-old patient, angiography showed severe narrowing of the suprarenal segment of the abdominal aorta. Thoraco-abdominal bypass with a 16 mm dacronic tubular graft was performed. In the 4-year-old patient angiography also showed a suprarenal aorta narrowing. In the first act patch angioplasty was performed and after PTA of the visceral arteries was done on several occasions. In the 55-year-old patient, after diagnostic angiography, infrarenal aorta coarctation was registered. PTA was performed with stent placement. All patients were asymptomatic on control check-ups. Conclusion. Abdominal coarctation is a pathological disease which is seldom found in vascular surgery. Angiography is of major importance for setting the diagnosis and for the control of the results of surgical and nonsurgical treatment. The combination of surgical and endovascular treatment in our patients showed very good results in the studied period.

  14. The isolated non-circular ringlets of Saturn

    International Nuclear Information System (INIS)

    Hill, J.R.; Mendis, D.A.

    1982-01-01

    It is shown that the combined effect of electrodynamic and gravitational forces can account for a number of features observed by Voyagers 1 and 2 in the isolated fine dust rings of Saturn. These include (a) the appearance and disappearance of the braids in the F-ring, (b) the eccentricities of the F-ring and the ringlets within the Encke and Cassine divisions and a gap in the C-ring, and (c) the kinks in the eccentric Encke ring. They may also account for the very existence of these rings. (Auth.)

  15. Fusion Rings for Quantum Groups

    DEFF Research Database (Denmark)

    Andersen, Henning Haahr; Stroppel, Catharina

    2014-01-01

    We study the fusion rings of tilting modules for a quantum group at a root of unity modulo the tensor ideal of negligible tilting modules. We identify them in type A with the combinatorial rings from Korff, C., Stroppel, C.: The sl(ˆn)k-WZNW fusion ring: a combinato-rial construction...... and a realisation as quotient of quantum cohomology. Adv. Math. 225(1), 200–268, (2010) and give a similar description of the sp2n-fusion ring in terms of non-commutative symmetric functions. Moreover we give a presentation of all fusion rings in classical types as quotients of polynomial rings. Finally we also...... compute the fusion rings for type G2....

  16. Tratamiento endovascular de las patologías de aorta -Estado del arte-: Parte 1 - Aneurismas de aorta abdominal Endovascular treatment of aortic pathologies -State of the art-: Part 1 - Aneurysms of abdominal aorta

    Directory of Open Access Journals (Sweden)

    Carlos E Uribe

    2007-12-01

    Full Text Available En la actualidad, el tratamiento endovascular de las patologías de aorta es una alternativa a la cirugía abierta. Éste ha demostrado ser seguro ya que arroja resultados iguales o superiores que el grupo quirúrgico. En este artículo se presenta el estado actual del tratamiento con endoprótesis de las patologías de aorta, así como las indicaciones, las contraindicaciones y el futuro del tratamiento con este tipo de dispositivos.Endovascular treatment of aortic pathologies is actually an alternative to open surgery. It has proven to be safe, showing similar or better results to those achieved by surgery. In this article, treatment of aortic pathologies by means of endoprosthesis is presented, as well as its indications, contraindications and future treatment with this kind of devices.

  17. Differences in the Thoracic Aorta by Region and Sex in a Murine Model of Marfan Syndrome

    Directory of Open Access Journals (Sweden)

    Francesc Jiménez-Altayó

    2017-11-01

    Full Text Available Marfan syndrome (MFS is a hereditary disorder of the connective tissue that causes life-threatening aortic aneurysm, which initiates at the aortic root and can progress into the ascending portion. However, analysis of ascending aorta reactivity in animal models of MFS has remained elusive. Epidemiologic evidence suggests that although MFS is equally prevalent in men and women, men are at a higher risk of aortic complications than non-pregnant women. Nevertheless, there is no experimental evidence to support this hypothesis. The aim of this study was to explore whether there are regional and sex differences in the thoracic aorta function of mice heterozygous for the fibrillin 1 (Fbn1 allele encoding a missense mutation (Fbn1C1039G/+, the most common class of mutation in MFS. Ascending and descending thoracic aorta reactivity was evaluated by wire myography. Ascending aorta mRNA and protein levels, and elastic fiber integrity were assessed by qRT-PCR, Western blotting, and Verhoeff-Van Gieson histological staining, respectively. MFS differently altered reactivity in the ascending and descending thoracic aorta by either increasing or decreasing phenylephrine contractions, respectively. When mice were separated by sex, contractions to phenylephrine increased progressively from 3 to 6 months of age in MFS ascending aortas of males, whereas contractions in females were unchanged. Endothelium-dependent relaxation was unaltered in the MFS ascending aorta of either sex; an effect related to augmented endothelium-dependent hyperpolarization-type dilations. In MFS males, the non-selective cyclooxygenase (COX inhibitor indomethacin prevented the MFS-induced enhancement of phenylephrine contractions linked to increased COX-2 expression. In MFS mice of both sexes, the non-selective nitric oxide synthase inhibitor L-NAME revealed negative feedback of nitric oxide on phenylephrine contractions, which was associated with upregulation of eNOS in females. Finally

  18. Differences in the Thoracic Aorta by Region and Sex in a Murine Model of Marfan Syndrome

    Science.gov (United States)

    Jiménez-Altayó, Francesc; Siegert, Anna-Maria; Bonorino, Fabio; Meirelles, Thayna; Barberà, Laura; Dantas, Ana P.; Vila, Elisabet; Egea, Gustavo

    2017-01-01

    Marfan syndrome (MFS) is a hereditary disorder of the connective tissue that causes life-threatening aortic aneurysm, which initiates at the aortic root and can progress into the ascending portion. However, analysis of ascending aorta reactivity in animal models of MFS has remained elusive. Epidemiologic evidence suggests that although MFS is equally prevalent in men and women, men are at a higher risk of aortic complications than non-pregnant women. Nevertheless, there is no experimental evidence to support this hypothesis. The aim of this study was to explore whether there are regional and sex differences in the thoracic aorta function of mice heterozygous for the fibrillin 1 (Fbn1) allele encoding a missense mutation (Fbn1C1039G/+), the most common class of mutation in MFS. Ascending and descending thoracic aorta reactivity was evaluated by wire myography. Ascending aorta mRNA and protein levels, and elastic fiber integrity were assessed by qRT-PCR, Western blotting, and Verhoeff-Van Gieson histological staining, respectively. MFS differently altered reactivity in the ascending and descending thoracic aorta by either increasing or decreasing phenylephrine contractions, respectively. When mice were separated by sex, contractions to phenylephrine increased progressively from 3 to 6 months of age in MFS ascending aortas of males, whereas contractions in females were unchanged. Endothelium-dependent relaxation was unaltered in the MFS ascending aorta of either sex; an effect related to augmented endothelium-dependent hyperpolarization-type dilations. In MFS males, the non-selective cyclooxygenase (COX) inhibitor indomethacin prevented the MFS-induced enhancement of phenylephrine contractions linked to increased COX-2 expression. In MFS mice of both sexes, the non-selective nitric oxide synthase inhibitor L-NAME revealed negative feedback of nitric oxide on phenylephrine contractions, which was associated with upregulation of eNOS in females. Finally, MFS ascending

  19. Tree Rings: Timekeepers of the Past.

    Science.gov (United States)

    Phipps, R. L.; McGowan, J.

    One of a series of general interest publications on science issues, this booklet describes the uses of tree rings in historical and biological recordkeeping. Separate sections cover the following topics: dating of tree rings, dating with tree rings, tree ring formation, tree ring identification, sample collections, tree ring cross dating, tree…

  20. Shape of the dilated aorta in children with bicuspid aortic valve

    International Nuclear Information System (INIS)

    Mart, Christopher R; McNerny, Bryn E

    2013-01-01

    The dilated aorta in adults with bicuspid aortic valve has been shown to have different shapes, but it is not known if this occurs in children. This observational study was performed to determine if there are different shapes of the dilated aorta in children with bicuspid aortic valve and their association with age, gender, hemodynamic alterations, and degree of aortic enlargement. One hundred and eighty-seven echocardiograms done on pediatric patients (0 – 18 years) for bicuspid aortic valve, during 2008, were reviewed. Aortic valve morphology, shape/size of the aorta, and pertinent hemodynamic alterations were documented. Aortic dilation was felt to be present when at least one aortic segment had a z-score > 2.0; global aortic enlargement was determined by summing the aortic segment z-scores. The aortic shape was assessed by age, gender, valve morphology, and hemodynamic alterations. Aortic dilation was present in 104/187 patients. The aorta had six different shapes designated from S1 through S6. There was no association between the aortic shape and gender, aortic valve morphology, or hemodynamic abnormalities. S3 was the most common after the age of six years and was associated with the most significant degree of global aortic enlargement. The shape of the dilated aorta in children with bicuspid aortic valve does not occur in a uniform manner and multiple shapes are seen. S2 and S3 are most commonly seen. As aortic dilation becomes more significant, a single shape (S3) becomes the dominant pattern

  1. Tensile characterisation of the aorta across quasi-static to blast loading strain rates

    Science.gov (United States)

    Magnus, Danyal; Proud, William; Haller, Antoine; Jouffroy, Apolline

    2017-06-01

    The dynamic tensile failure mechanisms of the aorta during Traumatic Aortic Injury (TAI) are poorly understood. In automotive incidents, where the aorta may be under strains of the order of 100/s, TAI is the second largest cause of mortality. In these studies, the proximal descending aorta is the most common site where rupture is observed. In particular, the transverse direction is most commonly affected due to the circumferential orientation of elastin, and hence the literature generally concentrates upon axial samples. This project extends these dynamic studies to the blast loading regime where strain-rates are of the order of 1000/s. A campaign of uniaxial tensile experiments are conducted at quasi-static, intermediate (drop-weight) and high (tensile Split-Hopkinson Pressure Bar) strain rates. In each case, murine and porcine aorta models are considered and the extent of damage assessed post-loading using histology. Experimental data will be compared against current viscoelastic models of the aorta under axial stress. Their applicability across strain rates will be discussed. Using a multi-disciplinary approach, the conditions applied to the samples replicate in vivo conditions, employing a blood simulant-filled tubular specimen surrounded by a physiological solution.

  2. Enfermedad ectasiante de la aorta abdominal: Morbilidad y mortalidad

    Directory of Open Access Journals (Sweden)

    Lilia E Chércoles Cazate

    1996-06-01

    Full Text Available Se presentó la experiencia de 10 años de trabajo (1983 a 1992, durante los cuales se atendieron 388 pacientes en el Hospital Provincial Docente "Saturnino Lora" de Santiago de Cuba, con el diagnóstico principal o asociado de aneurisma de la aorta abdominal. En el período analizado ingresaron en angiología y cirugía vascular 98 pacientes, 176 en medicina y 8 en otros servicios. Fallecieron a su llegada al cuerpo de guardia 106 por rotura del aneurisma o disección aórtica. Predominó el sexo masculino y la procedencia urbana. La hipertensión arterial fue la afección asociada más frecuente en los operados y la cardiopatía isquémica en los no operados. En los operados electivos, la complicación inmediata que más ocurrencia tuvo fue la trombosis de una rama de la prótesis y en los urgentes el sangramiento; mientras que en las mediatas, los operados electivos presentaron bronconeumonía y en los urgentes, anemia e íleo paralíticoThe experience of ten years of work (1983-1992 was presented. During that period, 388 patients with the main of associated diagnosis of abdominal aortic aneurysm were managed at the "Saturnino Lora" Provincial Educational Hospital, at Santiago de Cuba. In the decade analyzed, 98 patients entered in angiology and vascular surgery, 176 patients entered in medicine, and 8 in other services. In arriving to the emergency room, 106 subjects deceased due to aneurystic rupture or aortic dissection. Masculine sex and urban origin were prevailing. Arterial hypertension was the disease most frequently associated in the operated patients, and ischemic cardiac disease, among the non operated. In the elective operated patients, the immediate complication with the highest occurrence was the thrombosis of a branch of the prosthesis, and bleeding in the urgent cases, while in the mediate complications, the elective operated patients presented bronchopneumonia, and the urgent cases had anemia and paralytic ileus

  3. SOR-ring failure

    International Nuclear Information System (INIS)

    Kitamura, Hideo

    1981-01-01

    It was in the autumn of 1976 that the SOR-ring (synchrotron radiation storage ring) has commenced the regular operation. Since then, the period when the operation was interrupted due to the failures of SOR-ring itself is in total about 8 weeks. Failures and accidents have occurred most in the vacuum system. Those failure experiences are described on the vacuum, electromagnet, radio-frequency acceleration and beam transport systems with their interrupted periods. The eleven failures in the vacuum system have been reported, such as bellows breakage in a heating-evacuating period, leakage from the bellows of straight-through valves (made in U.S.A. and Japan), and leakage from the joint flange of the vacuum system. The longest interruption was 5 weeks due to the failure of a domestically manufactured straight-through valve. The failures of the electromagnet system involve the breakage in a cooling water system, short circuit of a winding in the Q magnet power transformer, blow of a fuse protecting the deflection magnet power source by the current less than the rating, and others. The failures of the RF acceleration system include the breakage of an output electronic tube the breakage of a cavity ceramic, RF voltage fluctuation due to the contact deterioration at a cavity electrode, and the failure of grid bias power source. It is necessary to select the highly reliable components for the vacuum system because the vacuum system failures require longer time for recovery, and very likely to induce secondary and tertiary failures. (Wakatsuki, Y.)

  4. Proton storage rings

    International Nuclear Information System (INIS)

    Rau, R.R.

    1978-04-01

    A discussion is given of proton storage ring beam dynamic characteristics. Topics considered include: (1) beam energy; (2) beam luminosity; (3) limits on beam current; (4) beam site; (5) crossing angle; (6) beam--beam interaction; (7) longitudinal instability; (8) effects of scattering processes; (9) beam production; and (10) high magnetic fields. Much of the discussion is related to the design parameters of ISABELLE, a 400 x 400 GeV proton---proton intersecting storage accelerator to be built at Brookhaven National Laboratory

  5. Ring-constrained Join

    DEFF Research Database (Denmark)

    Yiu, Man Lung; Karras, Panagiotis; Mamoulis, Nikos

    2008-01-01

    . This new operation has important applications in decision support, e.g., placing recycling stations at fair locations between restaurants and residential complexes. Clearly, RCJ is defined based on a geometric constraint but not on distances between points. Thus, our operation is fundamentally different......We introduce a novel spatial join operator, the ring-constrained join (RCJ). Given two sets P and Q of spatial points, the result of RCJ consists of pairs (p, q) (where p ε P, q ε Q) satisfying an intuitive geometric constraint: the smallest circle enclosing p and q contains no other points in P, Q...

  6. Femtoslicing in Storage Rings

    CERN Document Server

    Khan, Shaukat

    2005-01-01

    The generation of ultrashort synchrotron radiation pulses by laser-induced energy modulation of electrons and their subsequent transverse displacement, now dubbed "femtoslicing," was demonstrated at the Advanced Light Source in Berkeley. More recently, a femtoslicing user facility was commissioned at the BESSY storage ring in Berlin, and another project is in progress at the Swiss Light Source. The paper reviews the principle of femtoslicing, its merits and shortcomings, as well as the variations of its technical implementation. Various diagnostics techniques to detect successful laser-electron interaction are discussed and experimental results are presented.

  7. Viscosity of ring polymer melts

    KAUST Repository

    Pasquino, Rossana

    2013-10-15

    We have measured the linear rheology of critically purified ring polyisoprenes, polystyrenes, and polyethyleneoxides of different molar masses. The ratio of the zero-shear viscosities of linear polymer melts η0,linear to their ring counterparts η0,ring at isofrictional conditions is discussed as a function of the number of entanglements Z. In the unentangled regime η0,linear/η 0,ring is virtually constant, consistent with the earlier data, atomistic simulations, and the theoretical expectation η0,linear/ η0,ring = 2. In the entanglement regime, the Z-dependence of ring viscosity is much weaker than that of linear polymers, in qualitative agreement with predictions from scaling theory and simulations. The power-law extracted from the available experimental data in the rather limited range 1 < Z < 20, η0,linear/η0,ring ∼ Z 1.2±0.3, is weaker than the scaling prediction (η0,linear/η0,ring ∼ Z 1.6±0.3) and the simulations (η0,linear/ η0,ring ∼ Z2.0±0.3). Nevertheless, the present collection of state-of-the-art experimental data unambiguously demonstrates that rings exhibit a universal trend clearly departing from that of their linear counterparts, and hence it represents a major step toward resolving a 30-year-old problem. © 2013 American Chemical Society.

  8. Viscosity of ring polymer melts

    KAUST Repository

    Pasquino, Rossana; Vasilakopoulos, Thodoris C.; Jeong, Youncheol; Lee, Hyojoon; Rogers, Simon A.; Sakellariou, Georgios; Allgaier, Jü rgen B.; Takano, Atsushi; Brá s, Ana Rita E; Chang, Taihyun; Gooß en, Sebastian; Pyckhout-Hintzen, Wim; Wischnewski, Andreas; Hadjichristidis, Nikolaos; Richter, Dieter R.; Rubinstein, Michael H.; Vlassopoulos, Dimitris

    2013-01-01

    We have measured the linear rheology of critically purified ring polyisoprenes, polystyrenes, and polyethyleneoxides of different molar masses. The ratio of the zero-shear viscosities of linear polymer melts η0,linear to their ring counterparts η0,ring at isofrictional conditions is discussed as a function of the number of entanglements Z. In the unentangled regime η0,linear/η 0,ring is virtually constant, consistent with the earlier data, atomistic simulations, and the theoretical expectation η0,linear/ η0,ring = 2. In the entanglement regime, the Z-dependence of ring viscosity is much weaker than that of linear polymers, in qualitative agreement with predictions from scaling theory and simulations. The power-law extracted from the available experimental data in the rather limited range 1 < Z < 20, η0,linear/η0,ring ∼ Z 1.2±0.3, is weaker than the scaling prediction (η0,linear/η0,ring ∼ Z 1.6±0.3) and the simulations (η0,linear/ η0,ring ∼ Z2.0±0.3). Nevertheless, the present collection of state-of-the-art experimental data unambiguously demonstrates that rings exhibit a universal trend clearly departing from that of their linear counterparts, and hence it represents a major step toward resolving a 30-year-old problem. © 2013 American Chemical Society.

  9. Alpha - Skew Pi - Armendariz Rings

    Directory of Open Access Journals (Sweden)

    Areej M Abduldaim

    2018-03-01

    Full Text Available In this article we introduce a new concept called Alpha-skew Pi-Armendariz rings (Alpha - S Pi - ARas a generalization of the notion of Alpha-skew Armendariz rings.Another important goal behind studying this class of rings is to employ it in order to design a modern algorithm of an identification scheme according to the evolution of using modern algebra in the applications of the field of cryptography.We investigate general properties of this concept and give examples for illustration. Furthermore, this paperstudy the relationship between this concept and some previous notions related to Alpha-skew Armendariz rings. It clearly presents that every weak Alpha-skew Armendariz ring is Alpha-skew Pi-Armendariz (Alpha-S Pi-AR. Also, thisarticle showsthat the concepts of Alpha-skew Armendariz rings and Alpha-skew Pi- Armendariz rings are equivalent in case R is 2-primal and semiprime ring.Moreover, this paper proves for a semicommutative Alpha-compatible ringR that if R[x;Alpha] is nil-Armendariz, thenR is an Alpha-S Pi-AR. In addition, if R is an Alpha - S Pi -AR, 2-primal and semiprime ring, then N(R[x;Alpha]=N(R[x;Alpha]. Finally, we look forwardthat Alpha-skew Pi-Armendariz rings (Alpha-S Pi-ARbe more effect (due to their properties in the field of cryptography than Pi-Armendariz rings, weak Armendariz rings and others.For these properties and characterizations of the introduced concept Alpha-S Pi-AR, we aspire to design a novel algorithm of an identification scheme.

  10. Two-stage multilevel en bloc spondylectomy with resection and replacement of the aorta.

    Science.gov (United States)

    Gösling, Thomas; Pichlmaier, Maximilian A; Länger, Florian; Krettek, Christian; Hüfner, Tobias

    2013-05-01

    We report a case of multilevel spondylectomy in which resection and replacement of the adjacent aorta were done. Although spondylectomy is nowadays an established technique, no report on a combined aortic resection and replacement has been reported so far. The case of a 43-year-old man with a primary chondrosarcoma of the thoracic spine is presented. The local pathology necessitated resection of the aorta. We did a two-stage procedure with resection and replacement of the aorta using a heart-lung machine followed by secondary tumor resection and spinal reconstruction. The procedure was successful. A tumor-free margin was achieved. The patient is free of disease 48 months after surgery. En bloc spondylectomy in combination with aortic resection is feasible and might expand the possibility of producing tumor-free margins in special situations.

  11. Elastin and collagen fibre microstructure of the human aorta in ageing and disease: a review

    Science.gov (United States)

    Tsamis, Alkiviadis; Krawiec, Jeffrey T.; Vorp, David A.

    2013-01-01

    Aortic disease is a significant cause of death in developed countries. The most common forms of aortic disease are aneurysm, dissection, atherosclerotic occlusion and ageing-induced stiffening. The microstructure of the aortic tissue has been studied with great interest, because alteration of the quantity and/or architecture of the connective fibres (elastin and collagen) within the aortic wall, which directly imparts elasticity and strength, can lead to the mechanical and functional changes associated with these conditions. This review article summarizes the state of the art with respect to characterization of connective fibre microstructure in the wall of the human aorta in ageing and disease, with emphasis on the ascending thoracic aorta and abdominal aorta where the most common forms of aortic disease tend to occur. PMID:23536538

  12. Effect of high density lipoproteins on permeability of rabbit aorta to low density lipoproteins

    International Nuclear Information System (INIS)

    Klimov, A.N.; Popov, V.A.; Nagornev, V.A.; Pleskov, V.M.

    1985-01-01

    A study was made on the effect of high density lipoproteins (HDL) on the permeability of rabbit aorta to low density lipoproteins (LDL) after intravenous administration of human HDL and human ( 125 I)LDL to normal and hypercholesterolemic rabbits. Evaluation of radioactivity in plasma and aorta has shown that the administration of a large dose of HDL decreased the aorta permeability rate for ( 125 I)LDL on an average by 19% in normal rabbits, and by 45% in rabbits with moderate hypercholesterolemia. A historadiographic study showed that HDL also decreased the vessel wall permeability to ( 125 I)LDL in normal and particularly in hypercholesterolemic animals. The suggestion was made that HDL at very high molar concentration can hamper LDL transportation through the intact endothelial layer into the intima due to the ability of HDL to compete with LDL in sites of low affinity on the surface of endothelial cells. (author)

  13. Dietary fat level affecting histochemical radiosensitivity in dorsal aorta in rats

    International Nuclear Information System (INIS)

    Yousri, R.M.; Roushdy, H.M.; EL-Malkh, N.M.; Ashry, M.A.; Soliman, S.M.

    1988-01-01

    The present work has been conducted to investigate the effect of dietary fat status and/or cumulative whole body gamma radiation exposures up to 15 Gy the histochemical pattern of the dorsal aortas of male albino rats. Experimental animals were fed on either fat-rich or fat-free diet and the observations compared with those fed normal fat diet. The histochemical investigations has been confined to the concentration levels of mucopolysaccharide substance and total lipids. The dorsal aorta normal fat group showed higher content of PAS-positive material in the first two layers of the aorta wall in comparison with decreased amount of collagen fibers was shown in fat-rich group

  14. Diagnostic and therapy of acute thoracic aortic diseases; Diagnostik und Therapie akuter Erkrankungen der thorakalen Aorta

    Energy Technology Data Exchange (ETDEWEB)

    Schotten, Sebastian; Pitton, Michael B. [Universitaetsmedizin Mainz Univ. (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2017-09-15

    Acute diseases of the thoracic aorta represent a relatively rare but life threatening spectrum of pathologies. The non-traumatic diseases are usually summarized by the term ''acute aortic syndrome''. A timely diagnosis and initiation of therapy are cornerstones for the patient outcome. CT has become the standard imaging procedure due do its widespread availability and excellent sensitivity. Furthermore, CT is able to discriminate the variants of acute aortic diseases and to detect the wide spectrum of complications. The volumetric CT dataset is also the basis for planning of interventional procedures. Open surgical repair still represents the standard of care for acute pathologies of the ascending aorta while endovascular therapy, due to minimally invasive character and good outcome, has replaced open surgery in most cases of complicated lesions of the descending aorta.

  15. Thrombosis of abdominal aorta during cisplatin-based chemotherapy of testicular seminoma - a case report

    Directory of Open Access Journals (Sweden)

    Gehrckens Ralf

    2009-12-01

    Full Text Available Abstract Background Vascular complications occurring during cisplatin-based chemotherapy of germ cell tumours are inadequately recognized to date. Case Presentation A 49 year old man with advanced seminoma underwent two courses of chemotherapy according to the PEB regimen. Upon restaging, two thrombotic deposits were noted in the descending part of the thoracic aorta and in the infrarenal abdominal aorta, respectively. Although thrombotic plaques caused aortic occlusion of about 30%, no clinical signs of malperfusion of limbs were registered. The patient was placed on anticoagulant therapy. Six months after completion of chemotherapy, thrombotic deposits had completely resolved. In the absence of other predisposing factors, it must be assumed that cisplatin-based chemotherapy represented a strong stimulus for arterial thrombosis in the aorta. Conclusions This is the first case of endo-aortic thrombosis during chemotherapy for testicular germ cell cancer. Providers of chemotherapy must be aware of arterial thrombosis even in young patients with testicular cancer.

  16. Effect of camelina oil on the structure of aortas in rats

    DEFF Research Database (Denmark)

    Pawlowska, Marta; Harrison, Adrian Paul; Piersiak, Tomasz

    2016-01-01

    The aim of the present study was to determine whether a disturbance of hormonal homeostasis caused by ovariectomy influences the elasticity and wall structure of the abdominal aorta and whether camelina oil administration has an effect on the properties of the abdominal aorta in rats after...... ovariectomy. Forty Wistar female rats (220-240 g) were used in the experiment: 10 animals underwent a sham ovary repositioning operation (SHO), and 30 were ovariectomized (OVX). After 7 days of convalescence, the SHO rats and OVX1 rats were given physiological saline intragastrically for 6 weeks, while......), and images were obtained by light and confocal microscopy. Ovariectomy caused a significant decrease in the elasticity of the aorta, as well as in the volume of collagen III and elastin in the tunica intima and media, but no changes in the volume of collagen I, the total wall thickness or the thickness...

  17. Nitric oxide-dependent vasodilation and Ca2+ signalling induced by erythrodiol in rat aorta

    Directory of Open Access Journals (Sweden)

    Fidèle Ntchapda

    2015-06-01

    Full Text Available Objective: To evaluate the pharmacological property of erythrodiol, a natural triterpenoid contained in propolis, as vasodilatory agent, and to determine its mechanism of action. Methods: Rats aortic rings were isolated and suspended in organ baths, and the effects of erythrodiol were studied by means of isometric tension recording experiments. Nitric oxide (NO was detected by ozone-induced chemiluminescence. The technique used to evaluate changes in intracellular Ca2+ concentration in intact endothelium was opened aortic ring and loaded with 16 µmol Fura-2/AM for 60 min at room temperature, washed and fixed by small pins with the luminal face up. In situ, ECs were visualized by an upright epifluorescence Axiolab microscope (Carl Zeiss, Oberkochen, Germany equipped with a Zeiss×63 Achroplan objective (water immersion, 2.0 mm working distance, 0.9 numerical apertures. ECs were excited alternately at 340 and 380 nm, and the emitted light was detected at 510 nm. Results: In aortic rings with intact endothelium pre-contracted with norepinephrine (10-4 mol/L, the addition of erythrodiol (10-8-10-4 mol/L induced vasorelaxation in a concentration-dependent manner; in endothelium-denuded rings, the relaxant response induced by erythrodiol was almost completely abolished suggesting that vasorelaxation was endothelium-dependent. They had almost no relaxant effect on depolarised or endothelium-denuded aortic segments. The relaxation was significantly attenuated by pre-treatment with the NO synthase inhibitor Nvnitro-L-arginine-methylester. Erythrodiol (10-4 mol/L was able to significantly increase NOx levels. This effect was completely abolished after removal of the vascular endothelium. Erythrodiol (100 µmol/L caused a slow, long-lasting increase in intracellular Ca2+ concentration. These results further supported the hypothesis that erythrodiol can induce activation of the NO/soluble guanylate cyclase/cyclic guanosine monophosphate pathway, as

  18. Over length quantification of the multiaxial mechanical properties of the ascending, descending and abdominal aorta using Digital Image Correlation.

    Science.gov (United States)

    Peña, Juan A; Corral, Victoria; Martínez, Miguel A; Peña, Estefanía

    2018-01-01

    In this paper, we hypothesize that the biaxial mechanical properties of the aorta may be dependent on arterial location. To demonstrate any possible position-related difference, our study analyzed and compared the biaxial mechanical properties of the ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta stemming from the same porcine subjects, and reported values of constitutive parameters for well-known strain energy functions, showing how these mechanical properties are affected by location along the aorta. When comparing ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta, abdominal tissues were found to be stiffer and highly anisotropic. We found that the aorta changed from a more isotropic to a more anisotropic tissue and became progressively less compliant and stiffer with the distance to the heart. We observed substantial differences in the anisotropy parameter between aortic samples where abdominal samples were more anisotropic and nonlinear than the thoracic samples. The phenomenological model was not able to capture the passive biaxial properties of each specific porcine aorta over a wide range of biaxial deformations, showing the best prediction root mean square error ε=0.2621 for ascending thoracic samples and, especially, the worst for the infrarenal abdominal samples ε=0.3780. The micro-structured model with Bingham orientation density function was able to better predict biaxial deformations (ε=0.1372 for ascending thoracic aorta samples). The root mean square error of the micro-structural model and the micro-structured model with von Mises orientation density function were similar for all positions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. NRL ion ring program

    International Nuclear Information System (INIS)

    Kapetanakos, C.A.; Golden, J.; Drobot, A.; Mahaffey, R.A.; Marsh, S.J.; Pasour, J.A.

    1977-01-01

    An experiment is under way to form a storng proton ring using the 200 ka, 1.2 MeV, 50 nsec hollow proton beam recently generated at NRL. The 5 m long magnetic field configuration consists of a magnetic cusp, a compressing magnetic field, a gate field and a magnetic mirror. The midplane value of the magnetic mirror is such that the major radius of the ring will be about 10 cm. The degree of field reversal that will be achieved with 5 x 10 16 protons per pulse from the existing beam depends upon the field reversal is possible with the 600 kA proton beam that would be generated from the low inductance coaxial triode coupled to the upgraded Gamble II generator. The propagation and trapping of an intense proton beam in the experimental magnetic field configuration is investigated numerically. The results show that the self magnetic has a very pronounced effect on the dynamics of the gyrating protons

  20. Flexible ring seal

    International Nuclear Information System (INIS)

    Abbes, Claude; Gournier, Andre; Rouaud, Christian; Villepoix, Raymond de.

    1976-01-01

    The invention concerns a flexible metal ring seal, able to ensure a perfect seal between two bearings due to the crushing and elastic deformation properties akin to similar properties in elastomers. Various designs of seal of this kind are already known, particularly a seal made of a core formed by a helical wire spring with close-wound turns and with high axial compression ratio, closed on itself and having the shape of an annulus. This wire ring is surrounded by at least one envelope having at rest the shape of a toroidal surface of which the generating circle does not close on itself. In a particular design mode, the seal in question can include, around the internal spring, two envelopes of which one in contact with the spring is composed of a low ductility elastic metal, such as mild steel or stainless steel and the other is, on the contrary, made of a malleable metal, such as copper or nickel. The first envelope evenly distributes the partial crushing of the spring, when the seal is tightened, on the second envelope which closely fits the two surfaces between which the seal operates. The stress-crushing curve characteristic of the seal comprises two separate parts, the first with a relatively sharp slope corresponds to the start of the seal compression phase, enabling at least some of these curves to reach the requisite seal threshold very quickly, then, beyond this, a second part, practically flat, where the stress is appreciably constant for a wide operating bracket [fr

  1. Magnetization of two coupled rings

    International Nuclear Information System (INIS)

    Avishai, Y; Luck, J M

    2009-01-01

    We investigate the persistent currents and magnetization of a mesoscopic system consisting of two clean metallic rings sharing a single contact point in a magnetic field. Many novel features with respect to the single-ring geometry are underlined, including the explicit dependence of wavefunctions on the Aharonov-Bohm fluxes, the complex pattern of two-fold and three-fold degeneracies, the key role of length and flux commensurability, and in the case of commensurate ring lengths the occurrence of idle levels which do not carry any current. Spin-orbit interactions, induced by the electric fields of charged wires threading the rings, give rise to a peculiar version of the Aharonov-Casher effect where, unlike for a single ring, spin is not conserved. Remarkably enough, this can only be realized when the Aharonov-Bohm fluxes in both rings are neither integer nor half-integer multiples of the flux quantum

  2. Ovariectomy increases the participation of hyperpolarizing mechanisms in the relaxation of rat aorta.

    Directory of Open Access Journals (Sweden)

    Ana Sagredo

    Full Text Available This study examines the downstream NO release pathway and the contribution of different vasodilator mediators in the acetylcholine-induced response in rat aorta 5-months after the loss of ovarian function. Aortic segments from ovariectomized and control female Sprague-Dawley rats were used to measure: the levels of superoxide anion, the superoxide dismutases (SODs activity, the cGMP formation, the cGMP-dependent protein kinase (PKG activity and the involvement of NO, cGMP, hydrogen peroxide and hyperpolarizing mechanisms in the ACh-induced relaxation. The results showed that ovariectomy did not alter ACh-induced relaxation; incubation with L-NAME, a NO synthase inhibitor, decreased the ACh-induced response to a lesser extent in aorta from ovariectomized than from control rats, while ODQ, a guanylate cyclase inhibitor, decreased that response to a similar extent; the blockade of hyperpolarizing mechanisms, by precontracting arteries with KCl, decreased the ACh-induced response to a greater extent in aortas from ovariectomized than those from control rats; catalase, that decomposes hydrogen peroxide, decreased the ACh-induced response only in aorta from ovariectomized rats. In addition, ovariectomy increased superoxide anion levels and SODs activity, decreased cGMP formation and increased PKG activity. Despite the increased superoxide anion and decreased cGMP in aorta from ovariectomized rats, ACh-induced relaxation is maintained by the existence of hyperpolarizing mechanisms in which hydrogen peroxide participates. The greater contribution of hydrogen peroxide in ACh-induced relaxation is due to increased SOD activity, in an attempt to compensate for increased superoxide anion formation. Increased PKG activity could represent a redundant mechanism to ensure vasodilator function in the aorta of ovariectomized rats.

  3. Intraindividual assessment of the thoracic aorta using contrast and non-contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Tengg-Kobligk, Hendrik von; Gruenberg, K.M.; Giesel, F.L.; Ley-Zaporozhan, J.; Ley, S.; Henninger, V.; Kauczor, H.U.; Radiologische Universitaetsklinik Heidelberg; Boeckler, D.; Krummenauer, F.

    2009-01-01

    To avoid intravenous contrast media application, new MRA sequences using inherent blood contrast are available. The clinical use of these non-contrast-enhanced MRA (non-CE-MRA) sequences is still limited for the aorta. Thus, the goal was to compare a standard CE-MRA with a non-CE-MRA for the thoracic aorta. Ethics committee approval and informed consent were obtained. CE-MRA and non-CE-MRA (1.5T) were performed in the same 50 healthy volunteers (mean age: 48). CE-MRA: GRE-Turbo-Flash-3D (1.2 x 1.2 x 1.6 mm 3 ), 0.15 mmol Gd/kg, TA 22 ± 2sec. Non-CE-MRA: Respiratory-and cardiac-gated, T 2-prepared 3D-trueFISP (1.2 x 1.2 x 1.3 mm 3 ), TA 14 ± 5 min. Assessment included (3 readers, consensus): image quality (sharpness of vessel wall, signal homogeneity, artifacts) at the ascending aorta, arch, descending aorta and supra-aortic vessels. The image quality in the ascending aorta was rated 'excellent' in 78 %, 'moderate' in 22 %, 'poor' in 0 % for non-CE-MRA versus 22 %, 50 %, and 28 % for CE-MRA (Cohen's kappa = 29 %, McNemar p < 0.001). In a comparison of non-CE-MRA versus CE-MRA, the aortic arch and descending aorta showed no significant difference (kappa = 58 %/p = 0.250 and kappa = 100 %/p 1.000, respectively). Supra-aortic vessels were rated 'excellent' 45 %/49 %, 'moderate' 30 %/49 % and 'poor' 13 %/2 %, 12 % of supra-aortic vessels were visualized < 1 cm at non-CE-MRA. (orig.)

  4. Drop impact entrapment of bubble rings

    KAUST Repository

    Thoraval, M.-J.

    2013-04-29

    We use ultra-high-speed video imaging to look at the initial contact of a drop impacting on a liquid layer. We observe experimentally the vortex street and the bubble-ring entrapments predicted numerically, for high impact velocities, by Thoraval et al. (Phys. Rev. Lett., vol. 108, 2012, article 264506). These dynamics mainly occur within 50 -s after the first contact, requiring imaging at 1 million f.p.s. For a water drop impacting on a thin layer of water, the entrapment of isolated bubbles starts through azimuthal instability, which forms at low impact velocities, in the neck connecting the drop and pool. For Reynolds number Re above -12 000, up to 10 partial bubble rings have been observed at the base of the ejecta, starting when the contact is -20% of the drop size. More regular bubble rings are observed for a pool of ethanol or methanol. The video imaging shows rotation around some of these air cylinders, which can temporarily delay their breakup into micro-bubbles. The different refractive index in the pool liquid reveals the destabilization of the vortices and the formation of streamwise vortices and intricate vortex tangles. Fine-scale axisymmetry is thereby destroyed. We show also that the shape of the drop has a strong influence on these dynamics. 2013 Cambridge University Press.

  5. A case of Behcet's disease with aneurysms of common carotid arteries and abdominal aorta

    International Nuclear Information System (INIS)

    Choo, Yeon Myung; Chang, Kee Hyun; Choi, Sung Jae

    1984-01-01

    One case of Behcet's disease with multiple aneurysms in both common carotid arteries and abdominal aorta is presented with brief review of the literatures. A 26-year-old woman had slowly enlarging pulsatile masses in both sides of neck and recurrent ulcerations in oral cavity and genitalia. One day prior to admission, aphasia, right facial nerve palsy and right hemiplegia suddenly developed. Brain CT showed acute infarction in left basal ganglia. Both Carotid Angiography and abdominal Aortography demonstrated multiple aneurysms in both common carotid arteries and abdominal aorta with organizing thrombi and thromboembolism of internal carotid artery

  6. Estrutura, ultraestrutura e morfometria da aorta de paca (Cuniculus paca, Linnaeus, 1766) criada em cativeiro

    OpenAIRE

    Garcia Filho,S.P.; Martins,L.L.; Reis,A.C.G.; Pacheco,M.R.; Machado,M.R.F.

    2012-01-01

    Descreveram-se a morfologia, morfometria e ultraestrutura de segmentos das porções torácica e abdominal da aorta de quatro pacas (Cuniculus paca) adultas. Os segmentos aórticos foram analisados à microscopia de luz e à microscopia eletrônica de varredura. Mensuraram-se as espessuras do complexo formado pelas túnicas íntima e média, além da túnica adventícia. Os valores referentes à espessura do complexo formado pelas túnicas íntima e média da aorta torácica cranial foram significativamente ma...

  7. Coarctation of the aorta and renal artery stenosis in tuberous sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, P M; Robinson, M B; Stapleton, F B; Roy, S III; Koh, G; Tonkin, I L.D.

    1984-07-01

    Among neurocutaneous disorders, coarctation of the abdominal aorta and renal artery stenosis have traditionally been associated with neurofibromatosis. We report a 5-year-old girl who was discovered to have bilateral renal artery stenosis, coarctation of the abdominal aorta, renal cysts and typical skin lesions of tuberous clerosis during the evaluation of asymptomatic hypertension. Renal vascular hypertension has not been reported previously in tuberous sclerosis. We conclude that the tuberous sclerosis complex should be expanded to include vascular malformations and the hypertension should not be assumed to be secondary to renal hamartomata or cysts in patients with tuberous sclerosis.

  8. Coarctation of the aorta and renal artery stenosis in tuberous sclerosis

    International Nuclear Information System (INIS)

    Flynn, P.M.; Robinson, M.B.; Stapleton, F.B.; Roy, S. III; Koh, G.; Tonkin, I.L.D.; Tennessee Univ., Memphis; Tennessee Univ., Memphis; LeBonheur Children's Medical Center, Memphis, TN

    1984-01-01

    Among neurocutaneous disorders, coarctation of the abdominal aorta and renal artery stenosis have traditionally been associated with neurofibromatosis. We report a 5-year-old girl who was discovered to have bilateral renal artery stenosis, coarctation of the abdominal aorta, renal cysts and typical skin lesions of tuberous clerosis during the evaluation of asymptomatic hypertension. Renal vascular hypertension has not been reported previously in tuberous sclerosis. We conclude that the tuberous sclerosis complex should be expanded to include vascular malformations and the hypertension should not be assumed to be secondary to renal hamartomata or cysts in patients with tuberous sclerosis. (orig.)

  9. [Pathophysiology, prophylaxis and treatment of reperfusion syndrome in the surgery of abdominal aorta aneurysm].

    Science.gov (United States)

    Sukharev, I I; Guch, A A; Medvedskyĭ, E B; Kostylev, M V; Kornitskaia, A I; Gindich, L A; Dominiak, A B; Vlaĭkov, G G

    1999-01-01

    The peroxidal oxidation of the lipids state was studied up, as well as of the whole blood neutrophils functional activity, hemodynamics and microcirculation of lower extremities in surgical treatment of the abdominal aorta aneurysm. The main significance in the reperfusional syndrome pathophysiology, caused by temporary overcompression of aorta, has the neutrophils activation, their interrelationship with the endothelium cells and the activity lowering of the tissue antioxidant system, manifestated by vascular spasm, which is mostly expressed in the patients with stenotic affection of the lower extremities arteries. Positive effect was noted in application of preparation corvitin, which has antioxidant action.

  10. Flow visualisation study of spiral flow in the aorta-renal bifurcation.

    Science.gov (United States)

    Fulker, David; Javadzadegan, Ashkan; Li, Zuming; Barber, Tracie

    2017-10-01

    The aim of this study was to analyse the flow dynamics in an idealised model of the aorta-renal bifurcation using flow visualisation, with a particular focus on the effect of aorta-to-renal flow ratio and flow spirality. The recirculation length was longest when there was low flow in the renal artery and smaller in the presence of spiral flow. The results also indicate that patients without spiral flow or who have low flow in the renal artery due to the presence of stenosis may be susceptible to heightened development of atherosclerotic lesions.

  11. Morphological state of aorta in the fetuses and newborns suffered from chronic intrauterine hypoxia (experimental research

    Directory of Open Access Journals (Sweden)

    O. V. Kaluzhina

    2015-04-01

    Full Text Available The cardiovascular system in newborns with chronic hypoxia is affected in 40–70%. Aim. To investigate morphological state of aorta in the fetuses and newborns suffered from chronic intrauterine hypoxia. Methods and results. Aortic wall was investigated with modern morphological methods in 34 laboratory animals in order to identify the morphological features of the fetuses and newborns’ vessel affected by this pathogenic factor. It was established that chronic hypoxia leads to endothelial trophics deterioration, its flattening, dystrophic processes with following cells desquamation, density reduction of smooth muscle cells, thickening of the intima-media. Conclusion. It shows alterative-sclerotic changes in aorta in cases with chronic hypoxia influence.

  12. Split ring containment attachment device

    International Nuclear Information System (INIS)

    Sammel, A.G.

    1996-01-01

    A containment attachment device is described for operatively connecting a glovebag to plastic sheeting covering hazardous material. The device includes an inner split ring member connected on one end to a middle ring member wherein the free end of the split ring member is inserted through a slit in the plastic sheeting to captively engage a generally circular portion of the plastic sheeting. A collar potion having an outer ring portion is provided with fastening means for securing the device together wherein the glovebag is operatively connected to the collar portion. 5 figs

  13. Radar imaging of Saturn's rings

    Science.gov (United States)

    Nicholson, Philip D.; French, Richard G.; Campbell, Donald B.; Margot, Jean-Luc; Nolan, Michael C.; Black, Gregory J.; Salo, Heikki J.

    2005-09-01

    We present delay-Doppler images of Saturn's rings based on radar observations made at Arecibo Observatory between 1999 and 2003, at a wavelength of 12.6 cm and at ring opening angles of 20.1°⩽|B|⩽26.7°. The average radar cross-section of the A ring is ˜77% relative to that of the B ring, while a stringent upper limit of 3% is placed on the cross-section of the C ring and 9% on that of the Cassini Division. These results are consistent with those obtained by Ostro et al. [1982, Icarus 49, 367-381] from radar observations at |B|=21.4°, but provide higher resolution maps of the rings' reflectivity profile. The average cross-section of the A and B rings, normalized by their projected unblocked area, is found to have decreased from 1.25±0.31 to 0.74±0.19 as the rings have opened up, while the circular polarization ratio has increased from 0.64±0.06 to 0.77±0.06. The steep decrease in cross-section is at variance with previous radar measurements [Ostro et al., 1980, Icarus 41, 381-388], and neither this nor the polarization variations are easily understood within the framework of either classical, many-particle-thick or monolayer ring models. One possible explanation involves vertical size segregation in the rings, whereby observations at larger elevation angles which see deeper into the rings preferentially see the larger particles concentrated near the rings' mid-plane. These larger particles may be less reflective and/or rougher and thus more depolarizing than the smaller ones. Images from all four years show a strong m=2 azimuthal asymmetry in the reflectivity of the A ring, with an amplitude of ±20% and minima at longitudes of 67±4° and 247±4° from the sub-Earth point. We attribute the asymmetry to the presence of gravitational wakes in the A ring as invoked by Colombo et al. [1976, Nature 264, 344-345] to explain the similar asymmetry long seen at optical wavelengths. A simple radiative transfer model suggests that the enhancement of the azimuthal

  14. Magnetic ring for stripping enhancement

    International Nuclear Information System (INIS)

    Selph, F.

    1992-10-01

    A ring designed to recycle ions through a stripping medium offers the possibility for increasing output of the desired charge state by up to 4x. This could be a very important component of a Radioactive Nuclear Beam Facility. In order for such a ring to work effectively it must satisfy certain design conditions. These include achromaticity at the stripper, a dispersed region for an extraction magnet, and a number of first and higher order optics constraints which are necessary to insure that the beam emittance is not degraded unduly by the ring. An example is given of a candidate design of a stripping ring

  15. Saturn's Rings Edge-on

    Science.gov (United States)

    1995-01-01

    In one of nature's most dramatic examples of 'now-you see-them, now-you-don't', NASA's Hubble Space Telescope captured Saturn on May 22, 1995 as the planet's magnificent ring system turned edge-on. This ring-plane crossing occurs approximately every 15 years when the Earth passes through Saturn's ring plane.For comparison, the top picture was taken by Hubble on December 1, 1994 and shows the rings in a more familiar configuration for Earth observers.The bottom picture was taken shortly before the ring plane crossing. The rings do not disappear completely because the edge of the rings reflects sunlight. The dark band across the middle of Saturn is the shadow of the rings cast on the planet (the Sun is almost 3 degrees above the ring plane.) The bright stripe directly above the ring shadow is caused by sunlight reflected off the rings onto Saturn's atmosphere. Two of Saturn's icy moons are visible as tiny starlike objects in or near the ring plane. They are, from left to right, Tethys (slightly above the ring plane) and Dione.This observation will be used to determine the time of ring-plane crossing and the thickness of the main rings and to search for as yet undiscovered satellites. Knowledge of the exact time of ring-plane crossing will lead to an improved determination of the rate at which Saturn 'wobbles' about its axis (polar precession).Both pictures were taken with Hubble's Wide Field Planetary Camera 2. The top image was taken in visible light. Saturn's disk appears different in the bottom image because a narrowband filter (which only lets through light that is not absorbed by methane gas in Saturn's atmosphere) was used to reduce the bright glare of the planet. Though Saturn is approximately 900 million miles away, Hubble can see details as small as 450 miles across.The Wide Field/Planetary Camera 2 was developed by the Jet Propulsion Laboratory and managed by the Goddard Spaced Flight Center for NASA's Office of Space Science.This image and other images and

  16. Acceleration of magnetized plasma rings

    International Nuclear Information System (INIS)

    Hartman, D.; Eddleman, J.; Hammer, J.H.

    1982-01-01

    One scheme is considered, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focussing) during acceleration. Because the allowable acceleration force F/sub a/ = kappa U/sub m//R (kappa - 2 , the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case however, since the accelerating flux can expand as the ring moves, most of the accelerating field energy can be converted into kinetic energy of the ring leading to high efficiency

  17. Ground Movement in SSRL Ring

    International Nuclear Information System (INIS)

    Sunikumar, Nikita

    2011-01-01

    Users of the Stanford Synchrotron Radiation Lightsource (SSRL) are being affected by diurnal motion of the synchrotron's storage ring, which undergoes structural changes due to outdoor temperature fluctuations. In order to minimize the effects of diurnal temperature fluctuations, especially on the vertical motion of the ring floor, scientists at SSRL tried three approaches: painting the storage ring white, covering the asphalt in the middle of the ring with highly reflective Mylar and installing Mylar on a portion of the ring roof and walls. Vertical motion in the storage ring is measured by a Hydrostatic Leveling System (HLS), which calculates the relative height of water in a pipe that extends around the ring. The 24-hr amplitude of the floor motion was determined using spectral analysis of HLS data, and the ratio of this amplitude before and after each experiment was used to quantitatively determine the efficacy of each approach. The results of this analysis showed that the Mylar did not have any significant effect on floor motion, although the whitewash project did yield a reduction in overall HLS variation of 15 percent. However, further analysis showed that the reduction can largely be attributed to a few local changes rather than an overall reduction in floor motion around the ring. Future work will consist of identifying and selectively insulating these local regions in order to find the driving force behind diurnal floor motion in the storage ring.

  18. ring og refleksion

    DEFF Research Database (Denmark)

    Wahlgren, B.; Rattleff, Pernille; Høyrup, S.

    State of the art inden for forskning om læring på arbejdspladsen samt gennemgang af læringsteori og refleksionsbegrebet hos Dewey, Dreyfus, Schön, Argyris, Kolb, Jarvis, Mezirow og Brookfield. Afsluttes med diskussion af syntetiseret model for læring på arbejdspladsen.......State of the art inden for forskning om læring på arbejdspladsen samt gennemgang af læringsteori og refleksionsbegrebet hos Dewey, Dreyfus, Schön, Argyris, Kolb, Jarvis, Mezirow og Brookfield. Afsluttes med diskussion af syntetiseret model for læring på arbejdspladsen....

  19. Helical CT of traumatic injuries of the thoracic aorta

    International Nuclear Information System (INIS)

    Mengozzi, E.; Burzi, M.; Miceli, M.; Lipparini, M.; Sartoni Galloni, S.

    2000-01-01

    Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline study, contrast-enhanced scans were acquired with pitch 1 in 87 patients. Helical CT showed aortic lesions in 9 of 256 patients examined. In all the 9 cases it was found a mediastinal hematoma and all of them had positive plain chest radiographic findings of mediastinal enlargement. Moreover, in 6 cases aortic knob blurring was also evident on plain chest film and in 5 cases depressed left mainstem bronchus and trachea deviation rightwards were observed. All aortic lesions were identified on axial scans and located at the isthmus of level. Aortic rupture was always depicted as pseudo diverticulum of the proximal descending tract and intimal flap. It was also found that periaortic hematoma in 6 cases and intramural hematoma in 1 case. There were non false positive results in the series: 7 patients with Helical CT diagnosis of aortic rupture were submitted to conventional aortography that confirmed both type and extension of the lesions as detected by Helical CT, and all findings were

  20. Metabolism of arachidonic acid in 1 yr old New Zealand white (NZW) and watanabe heritable hyperlipidemic (WHHL) rabbit aortas

    International Nuclear Information System (INIS)

    Pfister, S.L.; Schmitz, J.M.; Willerson, J.T.; Campbell, W.B.

    1986-01-01

    This study was designed to characterize the metabolism of arachidonic acid (AA) in normal and atherosclerotic aortas. Segments of aortas were obtained from 1 yr old NZW rabbits, and WHHL rabbits, a genetic model of athero-sclerosis resembling familial hypercholesterolemia. Aortas were incubated at 37 0 C for 15 min with 14 C-AA (5 x 10 -5 M) during stimulation by A23187. The media was extracted using octadecylsilica columns and resolved into metabolites by reverse-phase HPLC. Prostaglandins (PGs) were identified by comigration of 14 C-metabolites with standards. The monoxygenated metabolites of AA (HETEs) were resolved by normal-phase HPLC, and their structures confirmed by GC-MS. In extracts from NZW and WHHL aortas, approximately 14% and 6% of the total radioactivity was converted to PGs and HETEs, respectively. The major PG produced by NZW and WHHL aortas was 6-keto PGF/sub 1α/ with lesser amounts of PGE 2 . Similarly, NZW and WHHL aortas produced primarily 12- and 15-HETE with lesser amounts of 11-, 9-, 8-, and 5-HETE. There were no qualitative differences between NZW and WHHL aortas in PG and HETE production. Therefore, despite extensive atherosclerosis in aortas of WHHL rabbits, the vessels maintain the ability to synthesize PGs and HETEs

  1. Rotating ring-ring electrode theory and experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kellyb, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  2. The Rotating Ring-Ring Electrode. Theory and Experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kelly, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  3. Damping rings for CLIC

    CERN Document Server

    Jowett, John M; Zimmermann, Frank; Owen, H

    2001-01-01

    The Compact Linear Colider (CLIC) is designed to operate at 3 TeV centre-of-mass energy with a total luminosity of 10^35 cm^-2 s^-1. The overall system design leads to extremely demanding requirements on the bunch trains injected into the main libac at frequency of 100 Hz. In particular, the emittances of the intense bunches have to be about an order of magnitude smaller than presently achieved. We describe our approach to finding a damping ring design capable of meeting these requirements. Besides lattice design, emittance and damping rate considerations, a number of scattering and instability effects have to be incorporated into the optimisation of parameters. Among these, intra-bem scattering and the electron cloud effect are two of the most significant.

  4. Does the sun ring

    International Nuclear Information System (INIS)

    Isaak, G.R.

    1978-01-01

    The work of various groups, which have been investigating the possibility of measuring the periodicities of solar oscillations in an attempt to test theoretical models of the sun, is reported. In particular the observation of small velocity oscillations of the surface layers of the sun that permits the measurement of the sound waves (or phonons) in the solar atmosphere, is discussed. Oscillations with periods of 2.65 h, 58 and 40 min and amplitudes of 2.7, 0.8 and 0.7 ms -1 respectively are reported. Support for a periodicity at about 2.65 h from a number of other groups using other measuring techniques are considered. It is felt that the most probable interpretation of the observed solar oscillations is that the sun is a resonator which is ringing. (UK)

  5. Nitric oxide and catalase-sensitive relaxation by scutellarin in the mouse thoracic aorta.

    Science.gov (United States)

    Yang, Weimin; Lust, Robert M; Bofferding, April; Wingard, Christopher J

    2009-01-01

    The vascular activity of scutellarin (SCU), a flavonoid isolated from a Chinese traditional medicinal plant, was investigated in isolated thoracic aortic rings of mice. SCU-induced dose-dependent relaxation of phenylephrine (1 microM) stimulated contractions. This relaxation was reduced by endothelium removal, significantly reduced by both the nitric oxide synthase inhibitor (Nomega-nitro-L-arginine methylester, 300 microM) and slightly limited by the soluble guanylyl cyclase inhibitor (1 H-[1,2,4] oxidazolol [4,3-a] quinoxalin-1-one, 100 microM). The catalase inhibitor (3-amino-1,2,4-triazole, 50 mM) augmented the constriction and blocked the lowest SCU concentration relaxation, whereas catalase addition was without effect. Preincubation with 300 and 1000 microM SCU significantly suppressed the contractile dose-response to phenylephrine, causing both a significant rise in half maximal effective concentration and a decrease in the maximal developed force. Western blot analysis showed that SCU inhibition of contraction was independent of reductions in myosin light chain phosphorylation. These results suggested that SCU relaxation was predominantly endothelium dependent and likely involved the catalase-sensitive nitric oxide synthase signaling pathway, without loss of myosin phosphorylation. The potential clinical use of SCU may prove to be effective in increasing vasoreactivity, independently of smooth muscle contractile activity that is mediated by the 20-kDa myosin light chain phosphorylation.

  6. Protective effect of soybeans as protein source in the diet against cadmium-aorta redox and morphological alteration

    Energy Technology Data Exchange (ETDEWEB)

    Pérez Díaz, Matías F.F.; Acosta, Mariano; Mohamed, Fabián H.; Ferramola, Mariana L.; Oliveros, Liliana B.; Gimenez, María S., E-mail: marisofigime44@gmail.com

    2013-11-01

    We investigated the effects of cadmium exposition on thoracic aorta redox status and morphology, and the putative protective effect of soybeans in the diet. Male Wistar rats were separated into 6 groups: 3 fed with a diet containing casein and 3 containing soybeans, as protein source. Within each protein group, one was given tap water (control) and the other two tap water containing 15 and 100 ppm of Cd{sup 2+}, respectively, for two months. In rats fed with casein diet, 15 ppm of Cd induced an increase of thiobarbituric acid-reactive substances (TBARS), and of the catalase (CAT) and glutathione peroxidase (GPx) activities, which were even higher with 100 ppm of Cd{sup 2+}, in aorta. Also, 100 ppm Cd{sup 2+} exposure increased superoxide dismutase (CuZnSOD) activity; CAT, GPX, SOD, Nrf2 and metallothioneine II mRNA expressions and CAT, GPx and NOX-2 protein levels, compared with control. Aorta endothelial and cytoplasmic alterations were observed. However, with the soybeans diet, 15 and 100 ppm of Cd{sup 2+} did not modify TBARS levels; CAT, GPX and Nrf2 mRNA expressions; CAT, GPx and NOX-2 protein; and the aorta morphology, compared with control. The soybean diet attenuates the redox changes and protects against morphological alterations induced, in a dose-dependent way, by Cd in aorta. - Highlights: • Under casein diet, 100 ppm Cd{sup 2+} in drinking water induces oxidative stress in aorta. • Under casein diet, 100 ppm Cd{sup 2+} increases Nrf2, MT II and NOX2 expressions in aorta. • Under casein diet, 100 ppm Cd{sup 2+} induces morphological changes in rat aorta. • The soybean diet attenuates the redox changes induced by Cd in rat aorta. • The soybean diet attenuates morphological alterations induced by Cd in rat aorta.

  7. Protective effect of soybeans as protein source in the diet against cadmium-aorta redox and morphological alteration

    International Nuclear Information System (INIS)

    Pérez Díaz, Matías F.F.; Acosta, Mariano; Mohamed, Fabián H.; Ferramola, Mariana L.; Oliveros, Liliana B.; Gimenez, María S.

    2013-01-01

    We investigated the effects of cadmium exposition on thoracic aorta redox status and morphology, and the putative protective effect of soybeans in the diet. Male Wistar rats were separated into 6 groups: 3 fed with a diet containing casein and 3 containing soybeans, as protein source. Within each protein group, one was given tap water (control) and the other two tap water containing 15 and 100 ppm of Cd 2+ , respectively, for two months. In rats fed with casein diet, 15 ppm of Cd induced an increase of thiobarbituric acid-reactive substances (TBARS), and of the catalase (CAT) and glutathione peroxidase (GPx) activities, which were even higher with 100 ppm of Cd 2+ , in aorta. Also, 100 ppm Cd 2+ exposure increased superoxide dismutase (CuZnSOD) activity; CAT, GPX, SOD, Nrf2 and metallothioneine II mRNA expressions and CAT, GPx and NOX-2 protein levels, compared with control. Aorta endothelial and cytoplasmic alterations were observed. However, with the soybeans diet, 15 and 100 ppm of Cd 2+ did not modify TBARS levels; CAT, GPX and Nrf2 mRNA expressions; CAT, GPx and NOX-2 protein; and the aorta morphology, compared with control. The soybean diet attenuates the redox changes and protects against morphological alterations induced, in a dose-dependent way, by Cd in aorta. - Highlights: • Under casein diet, 100 ppm Cd 2+ in drinking water induces oxidative stress in aorta. • Under casein diet, 100 ppm Cd 2+ increases Nrf2, MT II and NOX2 expressions in aorta. • Under casein diet, 100 ppm Cd 2+ induces morphological changes in rat aorta. • The soybean diet attenuates the redox changes induced by Cd in rat aorta. • The soybean diet attenuates morphological alterations induced by Cd in rat aorta

  8. Accumulation of low density lipoprotein associated cholesterol in calcifying vesicle fractions correlates with intimal thickening in thoracic aortas of juvenile rabbits fed a supplemental cholesterol diet

    Directory of Open Access Journals (Sweden)

    Culley Nathan C

    2006-10-01

    Full Text Available Abstract Background It has been shown that calcifying vesicles play an important role in aortic calcification and that cholesterol content in the isolated vesicle fraction is increased when rabbits are fed supplemental cholesterol diets. Whether lipoprotein-associated cholesterols and other lipids are also increased in the vesicle fraction and whether the increase correlates with atherosclerosis remain unknown. Results Fourteen juvenile male rabbits fed an atherogenic diet containing 0.5% cholesterol and 2% peanut oil for 3 months developed varying degrees of hypercholesterolemia and intimal thickening in the ascending thoracic aorta. The correlation between these two parameters was insignificant, and likely attributable to the use of small numbers of rabbits in this study. Despite this lack of correlation, we demonstrate that the accumulation of cholesterol in calcifying vesicle fractions obtained from the collagenase-digested aorta fragments correlates well with intimal thickening (r2 = 0.98, p Conclusion When limited numbers of rabbits are used, LDL-C accumulation in calcifying vesicle fractions is a better biomarker for atherosclerosis than LDL-C levels in the serum. The close association of LDL-C with calcifying vesicles may play an important role in atherosclerosis and calcification.

  9. How Jupiter's Ring Was Discovered.

    Science.gov (United States)

    Elliot, James; Kerr, Richard

    1985-01-01

    "Rings" (by astronomer James Elliot and science writer Richard Kerr) is a nontechnical book about the discovery and exploration of ring systems from the time of Galileo to the era of the Voyager spacecraft. One of this book's chapters is presented. (JN)

  10. Pyrimidine-pyridine ring interconversion

    NARCIS (Netherlands)

    Plas, van der H.C.

    2003-01-01

    This chapter discusses the pyrimidine-to-pyridine ring transformation and pyridine-to-pyrimidine ring transformation. In nucleophile-induced pyrimidine-to-pyridine rearrangements, two types of reactions can be distinguished depending on the structure of the nucleophile: (1) reactions in which the

  11. Experiencia en el manejo endovascular para el tratamiento de la aorta torácica Experience in endovascular management for thoracic aorta treatment

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2007-12-01

    Full Text Available Antecedentes: el tratamiento endovascular ofrece la posibilidad de cubrir el origen de la disección y evitar que progrese hasta aneurisma de la aorta, y con ello demuestra una reducción en la mortalidad hasta del 16%. Objetivo: evaluar los resultados quirúrgicos en términos de morbi-mortalidad de los pacientes sometidos a manejo endovascular de las lesiones de la aorta torácica en la Fundación Cardiovascular de Colombia desde 2003 hasta 2005. Diseño-método: estudio longitudinal tipo descriptivo retrospectivo, en el que se evaluaron las historias clínicas de todos los pacientes sometidos a manejo endovascular de patología toracoabdominal; en éste sólo se incluyeron los pacientes con procedimientos de la aorta torácica, desde 2003 hasta 2005. El análisis de los datos se realizó en Stata/SE 8,0. Resultados: se realizaron procedimientos de aorta torácica en 16 pacientes. El 75% de los pacientes eran hombres con edad promedio de 55,9 ± 12,6 años. El 87,5% (14 pacientes presentaban disección aórtica tipo A o B; un paciente transección traumática de la aorta y un paciente aneurisma de aorta torácica descendente. Las disecciones agudas se presentaron en 78,6% (11 pacientes y las crónicas en 21,4% (3 pacientes. El promedio de endoprótesis usadas fue de 2,8 ± 1. La estancia en la unidad de cuidados intensivos fue de 3 ± 2,7 días. El 81,3% de los pacientes no presentaron complicaciones mayores. La mortalidad fue del 18,7% (3 pacientes. A todos se les realizó control post-operatorio con tomografía axial computarizada, con evolución satisfactoria. Conclusión: de acuerdo con los reportes de la literatura con mayor casuística, se considera que el manejo endovascular para el tratamiento de la disección, aneurisma o trauma aórtico es un procedimiento confiable que disminuye la morbi-mortalidad.Antecedents: endovascular treatment has the possibility of covering the dissection origin and to avoid its progression to aortic

  12. Binomial Rings: Axiomatisation, Transfer and Classification

    OpenAIRE

    Xantcha, Qimh Richey

    2011-01-01

    Hall's binomial rings, rings with binomial coefficients, are given an axiomatisation and proved identical to the numerical rings studied by Ekedahl. The Binomial Transfer Principle is established, enabling combinatorial proofs of algebraical identities. The finitely generated binomial rings are completely classified. An application to modules over binomial rings is given.

  13. Ionization cooling ring for muons

    Directory of Open Access Journals (Sweden)

    R. Palmer

    2005-06-01

    Full Text Available Practical ionization cooling rings could lead to lower cost or improved performance in neutrino factory or muon collider designs. The ring modeled here uses realistic three-dimensional fields. The performance of the ring compares favorably with the linear cooling channel used in the second U.S. Neutrino Factory Study. The normalized 6D emittance of an ideal ring is decreased by a factor of approximately 240, compared with a factor of only 15 for the linear channel. We also examine such real-world effects as windows on the absorbers and rf cavities and leaving empty lattice cells for injection and extraction. For realistic conditions the ring decreases the normalized 6D emittance by a factor of 49.

  14. Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis

    International Nuclear Information System (INIS)

    Smid, Michal; Ferda, Jiri; Baxa, Jan; Cech, Jakub; Hajek, Tomas; Kreuzberg, Boris; Rokyta, Richard

    2010-01-01

    Background: Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. Methods and results: A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. Conclusion: In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis.

  15. Relationship between aneurism of ascending part of aorta and syndrome of connective tissue dysplasia

    Directory of Open Access Journals (Sweden)

    Osovska N.Yu.

    2014-11-01

    Full Text Available The paper identifies the main reasons for the development of an aneurysm of the ascending aorta and predictors of its complications in patients of all ages. To determine the cause and age-associated risk factors for aneurysms there were examined 154 patients with the presence of the expansion of the root and / or ascending aorta of more than 40 mm, according to echocardiographic examination. Patients were divided into 4 categories by age: 18-29 years, 30-44 years 45-59 years 60-74 years. Instrumental methods of examination: echocardiography, ECG, ECG monitoring and blood pressure, heart rate variability, ultrasound of internal organs were used. Syndrome of connective tissue dysplasia was established according to the criteria of the working group of the British Society of Rheumatology. Joint hypermobility syndrome was determined according to the Brayton criteria. Statistical processing was carried out by methods of variation statistic program StatSoft "Statistica" v.10.0. It was established that in young and middle aged patients the cause of aneurysm of ascending aorta more often is connective tissue dysplasia syndrome. In older patients the main cause of aneurysm of ascending aorta is associated with left ventricular hypertrophy and decreased contractile function of the heart.

  16. Identification of 2 novel genes developmentally regulated in the mouse aorta-gonad-mesonephros region

    NARCIS (Netherlands)

    C. Orelio; E.A. Dzierzak (Elaine)

    2003-01-01

    textabstractThe first adult-repopulating hematopoietic stem cells (HSCs) emerge in the mouse aorta-gonad-mesonephros (AGM) region at embryonic day 10.5 prior to their appearance in the yolk sac and fetal liver. Although several genes are implicated in the regulation of HSCs, there

  17. Large mobile thrombus in non-atherosclerotic thoracic aorta as the source of peripheral arterial embolism

    Directory of Open Access Journals (Sweden)

    Brkovic Zoran

    2005-11-01

    Full Text Available Abstract The presence of thrombi in the atherosclerotic and/or aneurysmatic aorta with peripheral arterial embolism is a common scenario. Thrombus formation in a morphologically normal aorta, however, is a rare event. A 50 years old woman was admitted to the mergency department for pain, coldness, and anesthesia in the the left foot. She had a 25 years history of cigarette smoking, a history of postmenopausal hormone replacement therapy (HRT, hypercholesterolemia and hyperfibrinogenemia. An extensive serologic survey for hypercoagulability, including antiphospholipid antibodies, and vasculitis disorders was negative. Transesophageal echocardiography revealed a large, pedunculated and hypermobile thrombus attached to the aortic wall 5 cm distal of the left subclavian artery. The patient was admitted to the surgery department, where a 15 cm long fresh, parietal thrombus could be removed from the aorta showing no macroscopic wall lesions or any other morphologic abnormalities. This case report demonstrates the possibility of evolving a large, pedunculated thrombus in a morphologically intact aorta in a postmenopausal woman with thrombogenic conditions such as hyperfibrinogenemia, hypercholesterolemia, smoking and HRT. For these patients, profiling the individual risk and weighing the benefits against the potential risks is warranted before prescribing HRT.

  18. Aorta cross-section calculation and 3D visualization from CT or MRT data using VRML

    Science.gov (United States)

    Grabner, Guenther; Modritsch, Robert; Stiegmaier, Wolfgang; Grasser, Simon; Klinger, Thomas

    2005-04-01

    Quantification of vessel diameters of artherosclerotic or congenital stenosis is very important for the diagnosis of vascular diseases. The aorta extraction and cross-section calculation is a software-based application that offers a three-dimensional, platform-independent, colorized visualization of the extracted aorta with augmented reality information of MRT or CT datasets. This project is based on different types of specialized image processing algorithms, dynamical particle filtering and complex mathematical equations. From this three-dimensional model a calculation of minimal cross sections is performed. In user specified distances, the aorta is cut in differently defined directions which are created through vectors with varying length. The extracted aorta and the derived minimal cross-sections are then rendered with the marching cube algorithm and represented together in a three-dimensional virtual reality with a very high degree of immersion. The aim of this study was to develop an imaging software that delivers cardiologists the possibility of (i) furnishing fast vascular diagnosis, (ii) getting precise diameter information, (iii) being able to process exact, local stenosis detection (iv) having permanent data storing and easy access to former datasets, and (v) reliable documentation of results in form of tables and graphical printouts.

  19. COMPORTAMIENTO MECANICO DE LA AORTA ASCENDENTE: CARACTERZACION EXPERIMENTAL Y SIMULACION NUMERICA.

    OpenAIRE

    GARCIA HERRERA, CLAUDIO; GARCIA HERRERA, CLAUDIO

    2008-01-01

    En este trabajo se realiza una caracterización experimental y numérica del comportamiento mecánico de la pared de la aorta humana. Se destaca la importancia (le este tema debido al creciente interés cii coiiocer las propiedades y la respuesta mecánica de 193p.

  20. Factors influencing the mechanical behaviour of healthy human descending thoracic aorta

    International Nuclear Information System (INIS)

    Guinea, Gustavo V; Atienza, José M; Rojo, Francisco J; Yiqun, Li; Claes, Els; Elices, Manuel; García-Herrera, Claudio M; Goicolea, José M; García-Montero, Carlos; Burgos, Raúl L; Goicolea, Francisco J

    2010-01-01

    In recent times, significant effort has been made to understand the mechanical behaviour of the arterial wall and how it is affected by the different vascular pathologies. However, to be able to interpret the results correctly, it is essential that the influence of other factors, such as aging or anisotropy, be understood. Knowledge of mechanical behaviour of the aorta has been customarily constrained by lack of data on fresh aortic tissue, especially from healthy young individuals. In addition, information regarding the point of rupture is also very limited. In this study, the mechanical behaviour of the descending thoracic aorta of 28 organ donors with no apparent disease, whose ages vary from 17 to 60 years, is evaluated. Tensile tests up to rupture are carried out to evaluate the influence of age and wall anisotropy. Results reveal that the tensile strength and stretch at failure of healthy descending aortas show a significant reduction with age, falling abruptly beyond the age of 30. This fact places age as a key factor when mechanical properties of descending aorta are considered

  1. TAVR Through Heavily Calcified Aorta Following Atheroma Retrieval With the "Elevator" Technique.

    Science.gov (United States)

    Senguttuvan, N Boopathy; Ellozy, Sharif; Tejani, Furqan; Kovacic, Jason; Kini, Annapoorna S; Sharma, Samin K; Dangas, George D

    2015-10-01

    An 86-year-old Caucasian female with severe symptomatic, inoperable aortic stenosis was accepted for high-risk transfemoral transcatheter aortic valve replacement (TAVR) approach due to severe calcification of the aorta. During initial passage of a 22 Fr sheath, there was dislodgment with proximal migration of a circumferential tunnel of calcium from the infrarenal aorta. A novel "elevator" technique was used to secure and retrieve the dislodged aorta en bloc back to its original infrarenal aortic position and allow in situ fixation with stenting. A new TAVR system was then successfully placed through the stent and a 23 mm Edwards Sapien valve (Edwards Lifesciences) was implanted as planned. In case of calcification protruding into the lumen of the aorta and limiting the passage of the large valve delivery system sheath, the obstruction can be managed by stenting the calcification against the luminal wall under fluoroscopic and intravascular-ultrasound guidance, allowing successful passage of the valve delivery system. The elevator technique allows axial transportation of any calcified vascular fragments, should they become dislodged.

  2. Medical image of the week: atherosclerotic aneurysm of aortic arch and descecnding thoracic aorta

    Directory of Open Access Journals (Sweden)

    Parasram M

    2016-02-01

    Full Text Available No abstract available. Article truncated after 150 words. A 94-year-old Spanish-speaking woman presented to the hospital with intermittent episodes of dyspnea and abdominal pain for one week. Her past medical history was notable for 30 pack-year smoking history and hypertension, which was reportedly controlled with medical therapy. Physical exam showed trace peripheral edema bilaterally, intact peripheral pulses, and a mild abdominal bruit. Work up at the emergency department revealed a non-ST elevation myocardial infarction with troponin T of 0.34 ng/mL but no ST-wave abnormality on electrocardiography. Chest x-ray displayed an incidental thoracic aneurysm (Figure 1. Chest computed tomography with contrast demonstrated a continuous aneurysm of the aortic arch and descending thoracic aorta with diameters measuring 6.8 cm and 6 cm, respectively (Figure 2A and 2B. Eccentric thrombi are noted in the aortic arch and the descending aorta. Interestingly, the distal descending thoracic aorta curves as it transitions to the abdominal aorta, which is evidence of a tortuous descending ...

  3. Thoracic Aorta 3D Hemodynamics in Pediatric and Young Adult Patients With Bicuspid Aortic Valve

    NARCIS (Netherlands)

    Allen, Bradley D.; van Ooij, Pim; Barker, Alex J.; Carr, Maria; Gabbour, Maya; Schnell, Susanne; Jarvis, Kelly B.; Carr, James C.; Markl, Michael; Rigsby, Cynthia; Robinson, Joshua D.

    2015-01-01

    Background: To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. Methods: 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 +/- 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this

  4. Dissecting aneurysm of arch and descending thoracic aorta presenting as a left sided hemorrhagic pleural effusion

    Directory of Open Access Journals (Sweden)

    Shamim Shelley

    2010-01-01

    Full Text Available The most common cause of massive hemorrhagic effusion is malignancy. Herein we present a case of dissecting aneurysm of descending thoracic aorta presenting initially with shortness of breath due to left sided massive pleural effusion. Effusion was hemorrhagic in nature with high hematocrit value. CT scan of thorax with CT angiogram was done and that revealed the diagnosis.

  5. High Temporal Resolution Finite Element Simulations of the Aorta for Thoracic Impedance Cardiography

    NARCIS (Netherlands)

    Mühlsteff, J.; Ulbrich, M.; Paluchowski, P.; Leonhardt, S.

    2011-01-01

    Impedance cardiography (ICG) is a simple and cheap method to acquirehemodynamic parameters. Unfortunately, not all physiologic influences on the ICG signal have been identified, yet. In this work, the influence of the dynamics of the aorta have been analyzed using a simplified model of the human

  6. Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.

    Science.gov (United States)

    Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée

    2012-10-01

    We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.

  7. Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.

    Science.gov (United States)

    Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok

    2016-09-01

    Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Acute intramural hematoma of ascending aorta. CT findings and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Toshio; Sakuyama, Keiko; Hiekata, Tomizou; Yamanaka, Ikuo [St. Marianna Univ., Kanagawa (Japan). Yokohama Seibu Hospital; Kuroki, Kazunori; Ohyama, Yukio; Ishikawa, Tohru; Kawada, Tadanori; Akashi, Katsuya

    1997-12-01

    The purpose of this study was to describe the CT findings and clinical outcomes of nineteen patients with acute intramural hematoma (IMH) of the ascending aorta. Six patients underwent surgery on the emergency basis (3 patients) due to cardiac tamponade (n=2) and dilated aorta (n=1), and on the elective basis (3 patients) due to patent and enlarging false lumen. Among the 13 patients with medical management, four patients died from complications of IMH during the follow-up period (2 days-2.5 years). Transition to aortic dissection or enlargement of an intimal tear was noted in 5 patients (31%) in 1 to 6 weeks after onset. Three patients died of causes not related to IMH. Six patients had been alive 2 to 9 years after onset. Retrospective review revealed 10 patients (53%) as possible surgical candidates, and the other 9 patients as medically treated patients in the long-term follow-up. The surgical group showed cardiac tamponade or shock in 6 patients on admission and had pericardial effusion in all the patients on the initial CT scan. In the patients with acute IMH of the ascending aorta, surgery should be considered for severe clinical symptoms, pericardial effusion and large size of the ascending aorta (more than 4 cm) on CT scan, and for converting to a typical type A aortic dissection. CT scan had a major role in making an early diagnosis, in depicting a dangerous sign, and in monitoring its progression or resolution of IMH. (author)

  9. Unexpected death caused by rupture of a dilated aorta in an adult male with aortic coarctation

    DEFF Research Database (Denmark)

    Leth, Peter Mygind; Knudsen, Peter Juel Thiis

    2015-01-01

    Aortic coarctation (AC) is a congenital aortic narrowing. We describe for the first time the findings obtained by unenhanced post mortem computed tomography (PMCT) in a case where the death was caused by cardiac tamponade from a ruptured aneurysmal dilatation of the ascending aorta and the aortic...

  10. Ultrasonographic measurement of canine aorta and aortic inlet before and after administration of Propofol

    Directory of Open Access Journals (Sweden)

    Gh Assadnassab

    2008-11-01

    Full Text Available Induction of safe anesthesia is an important task in veterinary medicine. One of the drugs used for anesthesia is Propofol. In this study, five healthy German shepherd dogs were selected and standard echocardiographic procedure from the right parasternal axis view conducted to observe the aorta and aortic inlet in B-mode and M-mode display formats before and after anesthesia with 6 mg/kg of Propofol. In the short axis view, the dorso-ventral and transverse diameter of the aorta in B-mode display and in the long axis view, the systolic and diastolic diameter of the aortic inlet in M-mode display were measured. The average dorso-ventral and transverse diameter of aorta in normal dogs was 22.77±1.49 mm and 20.75± 1.34 mm respectively while in anesthetized dogs these figures were 22.02±0.87 mm and 20.64±1.19 mm respectively which were not significantly different from normal dogs. However, the mean diameter of aorta inlet in M-mode display during systole and diastole was 15.62±0.84 mm and 15.31±0.68 mm respectively in normal dogs and for anesthetized animals these figures were 21.60±1.23 mm during systole and 19.70±0.68 mm during diastole which were significantly different compared with the normal dogs.

  11. Ultrasound-enhanced delivery of targeted echogenic liposomes in a novel ex vivo mouse aorta model.

    Science.gov (United States)

    Hitchcock, Kathryn E; Caudell, Danielle N; Sutton, Jonathan T; Klegerman, Melvin E; Vela, Deborah; Pyne-Geithman, Gail J; Abruzzo, Todd; Cyr, Peppar E P; Geng, Yong-Jian; McPherson, David D; Holland, Christy K

    2010-06-15

    The goal of this study was to determine whether targeted, Rhodamine-labeled echogenic liposomes (Rh-ELIP) containing nanobubbles could be delivered to the arterial wall, and whether 1-MHz continuous wave ultrasound would enhance this delivery profile. Aortae excised from apolipoprotein-E-deficient (n=8) and wild-type (n=8) mice were mounted in a pulsatile flow system through which Rh-ELIP were delivered in a stream of bovine serum albumin. Half the aortae from each group were treated with 1-MHz continuous wave ultrasound at 0.49 MPa peak-to-peak pressure, and half underwent sham exposure. Ultrasound parameters were chosen to promote stable cavitation and avoid inertial cavitation. A broadband hydrophone was used to monitor cavitation activity. After treatment, aortic sections were prepared for histology and analyzed by an individual blinded to treatment conditions. Delivery of Rh-ELIP to the vascular endothelium was observed, and sub-endothelial penetration of Rh-ELIP was present in five of five ultrasound-treated aortae and was absent in those not exposed to ultrasound. However, the degree of penetration in the ultrasound-exposed aortae was variable. There was no evidence of ultrasound-mediated tissue damage in any specimen. Ultrasound-enhanced delivery within the arterial wall was demonstrated in this novel model, which allows quantitative evaluation of therapeutic delivery. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  12. HZE ⁵⁶Fe-ion irradiation induces endothelial dysfunction in rat aorta: role of xanthine oxidase.

    Science.gov (United States)

    Soucy, Kevin G; Lim, Hyun Kyo; Kim, Jae Hyung; Oh, Young; Attarzadeh, David O; Sevinc, Baris; Kuo, Maggie M; Shoukas, Artin A; Vazquez, Marcelo E; Berkowitz, Dan E

    2011-10-01

    Ionizing radiation has been implicated in the development of significant cardiovascular complications. Since radiation exposure is associated with space exploration, astronauts are potentially at increased risk of accelerated cardiovascular disease. This study investigated the effect of high atomic number, high-energy (HZE) iron-ion radiation on vascular and endothelial function as a model of space radiation. Rats were exposed to a single whole-body dose of iron-ion radiation at doses of 0, 0.5 or 1 Gy. In vivo aortic stiffness and ex vivo aortic tension responses were measured 6 and 8 months after exposure as indicators of chronic vascular injury. Rats exposed to 1 Gy iron ions demonstrated significantly increased aortic stiffness, as measured by pulse wave velocity. Aortic rings from irradiated rats exhibited impaired endothelial-dependent relaxation consistent with endothelial dysfunction. Acute xanthine oxidase (XO) inhibition or reactive oxygen species (ROS) scavenging restored endothelial-dependent responses to normal. In addition, XO activity was significantly elevated in rat aorta 4 months after whole-body irradiation. Furthermore, XO inhibition, initiated immediately after radiation exposure and continued until euthanasia, completely inhibited radiation-dependent XO activation. ROS production was elevated after 1 Gy irradiation while production of nitric oxide (NO) was significantly impaired. XO inhibition restored NO and ROS production. Finally, dietary XO inhibition preserved normal endothelial function and vascular stiffness after radiation exposure. These results demonstrate that radiation induced XO-dependent ROS production and nitroso-redox imbalance, leading to chronic vascular dysfunction. As a result, XO is a potential target for radioprotection. Enhancing the understanding of vascular radiation injury could lead to the development of effective methods to ameliorate radiation-induced vascular damage.

  13. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  14. Evaluation of ring impedance of the Photon Factory storage ring

    International Nuclear Information System (INIS)

    Kiuchi, T.; Izawa, M.; Tokumoto, S.; Hori, Y.; Sakanaka, S.; Kobayashi, M.; Kobayakawa, H.

    1992-05-01

    The loss parameters of the ducts in the Photon Factory (PF) storage ring were evaluated using the wire method and the code TBCI. Both the measurement and the calculation were done for a different bunch length (σ) ranging from 23 to 80 ps. The PF ring impedance was estimated to be |Z/n|=3.2 Ω using the broadband impedance model. The major contribution to the impedance comes from the bellows and the gate valve sections. Improvements of these components will lower the ring impedance by half. (author)

  15. DOMINANCE OF CORONARY ARTERY DISEASE AMONG PATIENTS WITH ANEURYSM OF ABDOMINAL AORTA

    Directory of Open Access Journals (Sweden)

    Maja Zdravkovic

    2007-12-01

    Full Text Available Persons with aneurysm of the abdominal aorta have high prevalence of risk factors of cardiovascular disease. It cannot be stated with certainty whether these persons die in a large number due to the existence of risk factors or the genesis and complications of aneurysm itself. In patients with aneurysm of the abdominal aorta, there is a high correlation with the coronary artery disease; therefore, the aim of the study was to prove whether or not this is the case. The patients in preparation for the resection of the abdominal aorta aneurysm at the Institute of Cardiovascular Disease underwent the examination. The study included 377 examinees, of whom 341 males and 36 females, aged 45 to 83 years, during the three-year interval (from 2004 to 2006. The aim of the study was to determine the dominance of the coronary artery disease among the patients with aneurysm of the abdominal aorta. In the process of analyzing the data obtained from patients and medical evidence, it was found out that a large number of the abdominal aortic aneurysm patients were at the same time the coronary artery disease patients (55,2%; Hi=15,04; p80 kg was larger, as well as the percentage of patients with hypertension (89% and increased levels of cholesterol and triglycerides (67%. There was a great number of those with the inherited factor (40%. It has been proven that the risk factors for the development of coronary artery disease are in direct association with the risk factors for the abdominal aortic aneurysm. Also, there is a great predominance of the coronary artery disease among the patients with aneurysm of the abdominal aorta. The coronary artery disease is one of the main risk factors. If we managed to prevent the appearance of this disease or achieve the timely diagnosing of it and eventual curing, we would be able to decrease the development of the abdominal aortic aneurysm well as the consequences and further complications.

  16. Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

    Science.gov (United States)

    Allen, Bradley D; van Ooij, Pim; Barker, Alex J; Carr, Maria; Gabbour, Maya; Schnell, Susanne; Jarvis, Kelly B; Carr, James C; Markl, Michael; Rigsby, Cynthia; Robinson, Joshua D

    2015-10-01

    To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 ± 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this Institutional Review Board-approved study. Nomogram-based aortic root Z-scores were calculated to assess aortic dilatation and degree of aortic stenosis (AS) severity was assessed on MRI. Data analysis included calculation of time-averaged systolic 3D wall shear stress (WSSsys ) along the entire aorta wall, and regional quantification of maximum and mean WSSsys and peak systolic velocity (velsys ) in the ascending aorta (AAo), arch, and descending aorta (DAo). The 4D flow MRI AAo velsys was also compared with echocardiography peak velocity measurements. There was a positive correlation with both mean and max AAo WSSsys and peak AAo velsys (mean: r = 0.84, P max: r = 0.94, P max: rS  = 0.70, P < 0.001). AAo peak velocity was significantly higher when measured with echo compared with 4D flow MRI (2.1 ± 0.98 m/s versus 1.27 ± 0.49 m/s, P < 0.001). In pediatric and young adult patients with BAV, AS and peak ascending aorta velocity are associated with increased AAo WSS, while aortic dilation, age, and body surface area do not significantly impact AAo hemodynamics. Prospective studies are required to establish the role of WSS as a risk-stratification tool in these patients. © 2015 Wiley Periodicals, Inc.

  17. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  18. Tinkering at the main-ring lattice

    Energy Technology Data Exchange (ETDEWEB)

    Ohnuma, S.

    1982-08-23

    To improve production of usable antiprotons using the proton beam from the main ring and the lossless injection of cooled antiprotons into the main ring, modifications of the main ring lattice are recommended.

  19. Is the bell ringing?

    CERN Multimedia

    Francesco Poppi

    2010-01-01

    During the Nobel prize-winning UA1 experiment, scientists in the control room used to ring a bell if a particularly interesting event had occurred. Today, the “CMS Exotica hotline” routine produces a daily report that lists the exotic events that were recorded the day before.   Display of an event selected by the Exotica routine. Take just a very small fraction of the available data (max. 5%); define the events that you want to keep and set the parameters accordingly; run the Exotica routine and only look at the very few images that the system has selected for you. This is the recipe that a small team of CMS researchers has developed to identify the signals coming from possible new physics processes. “This approach does not replace the accurate data analysis on the whole set of data. However, it is a very fast and effective way to focus on just a few events that are potentially very interesting”, explains Maurizio Pierini (CERN), who developed the...

  20. Moving ring reactor 'Karin-1'

    International Nuclear Information System (INIS)

    1983-12-01

    The conceptual design of a moving ring reactor ''Karin-1'' has been carried out to advance fusion system design, to clarify the research and development problems, and to decide their priority. In order to attain these objectives, a D-T reactor with tritium breeding blanket is designed, a commercial reactor with net power output of 500 MWe is designed, the compatibility of plasma physics with fusion engineering is demonstrated, and some other guideline is indicated. A moving ring reactor is composed mainly of three parts. In the first formation section, a plasma ring is formed and heated up to ignition temperature. The plasma ring of compact torus is transported from the formation section through the next burning section to generate fusion power. Then the plasma ring moves into the last recovery section, and the energy and particles of the plasma ring are recovered. The outline of a moving ring reactor ''Karin-1'' is described. As a candidate material for the first wall, SiC was adopted to reduce the MHD effect and to minimize the interaction with neutrons and charged particles. The thin metal lining was applied to the SiC surface to solve the problem of the compatibility with lithium blanket. Plasma physics, the engineering aspect and the items of research and development are described. (Kako, I.)

  1. Quantum Fourier Transform Over Galois Rings

    OpenAIRE

    Zhang, Yong

    2009-01-01

    Galois rings are regarded as "building blocks" of a finite commutative ring with identity. There have been many papers on classical error correction codes over Galois rings published. As an important warm-up before exploring quantum algorithms and quantum error correction codes over Galois rings, we study the quantum Fourier transform (QFT) over Galois rings and prove it can be efficiently preformed on a quantum computer. The properties of the QFT over Galois rings lead to the quantum algorit...

  2. Functional roles of the pepper RING finger protein gene, CaRING1, in abscisic acid signaling and dehydration tolerance.

    Science.gov (United States)

    Lim, Chae Woo; Hwang, Byung Kook; Lee, Sung Chul

    2015-09-01

    Plants are constantly exposed to a variety of biotic and abiotic stresses, which include pathogens and conditions of high salinity, low temperature, and drought. Abscisic acid (ABA) is a major plant hormone involved in signal transduction pathways that mediate the defense response of plants to abiotic stress. Previously, we isolated Ring finger protein gene (CaRING1) from pepper (Capsicum annuum), which is associated with resistance to bacterial pathogens, accompanied by hypersensitive cell death. Here, we report a new function of the CaRING1 gene product in the ABA-mediated defense responses of plants to dehydration stress. The expression of the CaRING1 gene was induced in pepper leaves treated with ABA or exposed to dehydration or NaCl. Virus-induced gene silencing of CaRING1 in pepper plants exhibited low degree of ABA-induced stomatal closure and high levels of transpirational water loss in dehydrated leaves. These led to be more vulnerable to dehydration stress in CaRING1-silenced pepper than in the control pepper, accompanied by reduction of ABA-regulated gene expression and low accumulation of ABA and H2O2. In contrast, CaRING1-overexpressing transgenic plants showed enhanced sensitivity to ABA during the seedling growth and establishment. These plants were also more tolerant to dehydration stress than the wild-type plants because of high ABA accumulation, enhanced stomatal closure and increased expression of stress-responsive genes. Together, these results suggest that the CaRING1 acts as positive factor for dehydration tolerance in Arabidopsis by modulating ABA biosynthesis and ABA-mediated stomatal closing and gene expression.

  3. Polarized particles in storage rings

    International Nuclear Information System (INIS)

    Derbenev, Ya.S.; Kondratenko, A.M.; Serednyakov, S.I.; Skrinskij, A.N.; Tumajkin, G.M.; Shatunov, Yu.M.

    1977-01-01

    Experiments with polarized beams on the VEPP-2M and SPEAK storage rings are described. Possible methods of producing polarized particle beams in storage rings as well as method of polarization monitoring are counted. Considered are the processes of radiation polarization of electrons and positrons. It is shown, that to preserve radiation polarization the introduction of regions with a strong sign-variable magnetic field is recommended. Methods of polarization measurement are counted. It is suggested for high energies to use dependence of synchrotron radiation power on transverse polarization of electrons and positrons. Examples of using polarizability of colliding beams in storage rings are presented

  4. Researches on the Piston Ring

    Science.gov (United States)

    Ehihara, Keikiti

    1944-01-01

    In internal combustion engines, steam engines, air compressors, and so forth, the piston ring plays an important role. Especially, the recent development of Diesel engines which require a high compression pressure for their working, makes, nowadays, the packing action of the piston ring far more important than ever. Though a number of papers have been published in regard to researches on the problem of the piston ring, none has yet dealt with an exact measurement of pressure exerted on the cylinder wall at any given point of the ring. The only paper that can be traced on this subject so far is Mr. Nakagawa's report on the determination of the relative distribution of pressure on the cylinder wall, but the measuring method adopted therein appears to need further consideration. No exact idea has yet been obtained as to how the obturation of gas between the piston and cylinder, the frictional resistance of the piston, and the wear of the cylinder wall are affected by the intensity and the distribution of the radial pressure of the piston ring. Consequently, the author has endeavored, by employing an apparatus of his own invention, to get an exact determination of the pressure distribution of the piston ring. By means of a newly devised ring tester, to which piezoelectricity of quartz was applied, the distribution of the radial pressure of many sample rings on the market was accurately determined. Since many famous piston rings show very irregular pressure distribution, the author investigated and achieved a manufacturing process of the piston ring which will exert uniform pressure on the cylinder wall. Temperature effects on the configuration and on the mean spring power have also been studied. Further, the tests were performed to ascertain how the gas tightness of the piston ring may be affected by the number or spring power. The researches as to the frictional resistance between the piston ring and the cylinder wall were carried out, too. The procedure of study, and

  5. Soft Congruence Relations over Rings

    Science.gov (United States)

    Xin, Xiaolong; Li, Wenting

    2014-01-01

    Molodtsov introduced the concept of soft sets, which can be seen as a new mathematical tool for dealing with uncertainty. In this paper, we initiate the study of soft congruence relations by using the soft set theory. The notions of soft quotient rings, generalized soft ideals and generalized soft quotient rings, are introduced, and several related properties are investigated. Also, we obtain a one-to-one correspondence between soft congruence relations and idealistic soft rings and a one-to-one correspondence between soft congruence relations and soft ideals. In particular, the first, second, and third soft isomorphism theorems are established, respectively. PMID:24949493

  6. Distributively generated matrix near rings

    International Nuclear Information System (INIS)

    Abbasi, S.J.

    1993-04-01

    It is known that if R is a near ring with identity then (I,+) is abelian if (I + ,+) is abelian and (I,+) is abelian if (I*,+) is abelian [S.J. Abbasi, J.D.P. Meldrum, 1991]. This paper extends these results. We show that if R is a distributively generated near ring with identity then (I,+) is included in Z(R), the center of R, if (I + ,+) is included in Z(M n (R)), the center of matrix near ring M n (R). Furthermore (I,+) is included in Z(R) if (I*,+) is included in Z(M n (R)). (author). 5 refs

  7. SMARANDACHE NON-ASSOCIATIVE RINGS

    OpenAIRE

    Vasantha, Kandasamy

    2002-01-01

    An associative ring is just realized or built using reals or complex; finite or infinite by defining two binary operations on it. But on the contrary when we want to define or study or even introduce a non-associative ring we need two separate algebraic structures say a commutative ring with 1 (or a field) together with a loop or a groupoid or a vector space or a linear algebra. The two non-associative well-known algebras viz. Lie algebras and Jordan algebras are mainly built using a vecto...

  8. Ultra-sonografia da aorta abdominal e de seus ramos em cães Ultrasonography of abdominal aorta and its branches in dogs

    Directory of Open Access Journals (Sweden)

    Lilian Kamikawa

    2007-04-01

    Full Text Available O ultra-som bidimensional e o ultra-som Doppler foram utilizados para avaliar a biometria e a hemodinâmica da aorta abdominal e artérias ilíacas externas de 131cães clinicamente normais. Os resultados da avaliação biométrica da aorta abdominal indicaram um diâmetro médio de 0,80cm para o seu segmento diafragmático (AOD; 0,74cm para o seu segmento caudal às artérias renais (AOR e 0,69cm para o segmento cranial à sua bifurcação (AOT. A artéria ilíaca externa direita (AIED apresentou o diâmetro médio de 0,42cm e a artéria ilíaca externa esquerda (AIEE o diâmetro médio de 0,39. O estudo hemodinâmico da aorta abdominal apresentou velocidade de pico sistólico médio de 104,00cm/s para AOR; 99,61cm/s para AOT; 85,47cm/s para AIED e 99,51cm/s para AIEE. Verificaram-se correlações de diferentes intensidades entre os diâmetros vasculares em diferentes pontos de tomadas e os fatores biométricos corpóreos (CRL. Correlações baixas foram observadas quando esses diâmetros foram confrontados com a idade.A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate the biometric and the hemodynamic of abdominal aorta and external iliac arteries of a hundred and thirty one normal dogs. Results of biometrics of abdominal aorta, presented a mean diameter of 0.80cm in its diaphragmatic segment (AOD; 0.74cm in its segment caudal to the renal arteries (AOR and 0.69cm in the segment cranial to its termination (AOT. The right-external-iliac artery (AIED presented a mean diameter of 0.42cm and the left-external iliac artery (AIEE a mean diameter of 0.39cm. The hemodynamic study of the abdominal aorta presented a medium systolic peak velocity to AOR of 104cm per sec.; to AOT of 99.61cm per sec.; to AIED of 85.47cm per sec. and to AIEE of 99.51cm per sec. Correlations of different intensities between the vascular diameters have been verified between the

  9. Isolated aneurysms of the iliac arteries

    International Nuclear Information System (INIS)

    Eckmann, A.; Schild, H.; Schmiedt, W.; Groenninger, J.

    1988-01-01

    Isolated aneurysms of the iliac arteries are rare. They must be considered as a disease pattern of their own as against aneurysms of the abdominal aorta because of the specific anatomical conditions in the pelvis. The clinical symptomatology is determinated by their localisation and topographical relationships within teh pelvis; this can give rise to problems in differential diagnosis primary urological, neurological or gastrointestinal diseases. The prognosis is decisively determined early and correct diagnosis because of the danger of rupture. Sonography, computed tomography and angiography are indispensable aids in preoperative planning. (orig.) [de

  10. A comparison of reactive oxygen species metabolism in the rat aorta and vena cava: focus on xanthine oxidase.

    Science.gov (United States)

    Szasz, Theodora; Thompson, Janice M; Watts, Stephanie W

    2008-09-01

    Reactive oxygen species (ROS) are important mediators in vascular biology. Venous function, although relevant to cardiovascular disease, is still understudied. We compared aspects of ROS metabolism between a major artery (the aorta) and a major vein (the vena cava, VC) of the rat, with the hypothesis that venous ROS metabolism would be overall increased compared with its arterial counterpart. Superoxide and hydrogen peroxide (H2O2) release in basal conditions was higher in VC compared with aorta. The antioxidant capacity for H2O2 was also higher in VC than in aorta. Exogenous superoxide induced a higher contraction in VC compared with aorta. Protein expression of three major ROS metabolizing enzymes, xanthine oxidase (XO), CuZn-SOD, and catalase, was higher in VC compared with aorta. Because XO seemed a likely source of the higher VC ROS levels, we examined it further and found higher mRNA expression and activity of XO in VC compared with aorta. We also investigated the impact of XO inhibition by allopurinol on aorta and VC functional responses to norepinephrine, ANG II, ET-1, and ACh. Maximal ET-1-mediated contraction was decreased by allopurinol in VC but not in the aorta. Our results suggest that there are overall differences in ROS metabolism between aorta and VC, with the latter operating normally at a higher set point, releasing but also being able to handle, higher ROS levels. We propose XO to be an important source for these differences. The result of this particular comparison may be reflective of a general arteriovenous contrast.

  11. Reconstrução da aorta com conduto de pericárdio bovino corrugado

    Directory of Open Access Journals (Sweden)

    Claudio A. Salles

    1998-04-01

    Full Text Available No período de outubro de 1989 a maio de 1997, 40 pacientes portadores de dissecção aórtica, aneurisma da aorta, coarctação da aorta ou doença oclusiva aorto-ilíaca foram submetidos a reconstrução da aorta utilizando-se conduto de pericárdio bovino corrugado processado em glutaraldeído. A reconstrução total da aorta ascendente com substituição da valva aórtica e reimplante das artérias coronárias foi realizada em 9 pacientes, a simples substituição da aorta ascendente em 6, aorta torácica descendente em 2, arco aórtico em 1, aorta toracoabdominal em 1 e a aorta abdominal foi reconstruída em 21, incluindo pacientes submetidos a reconstrução aorto-ilíaca ou aorto-femoral. A mortalidade hospitalar foi de 8 (20% pacientes e as causas de óbito foram baixo débito cardíaco, recidiva da dissecção aórtica, falência de múltiplos órgãos e sangramento. O seguimento total foi de 128,4 pacientes-anos, com um seguimento médio de 4 anos por paciente. Complicações tardias relacionadas ao conduto vascular foram observadas em 4 pacientes, incluindo obstrução de um dos ramos do tubo bifurcado utilizado para reconstrução aorto-femoral e infecção em 3, resultando em degeneração secundária do conduto e formação de pseudo-aneurisma. Os 4 pacientes foram submetidos a reoperações, correspondendo a uma incidência de 3,1% ± 1,6% por paciente/ano. Ocorreram 5 óbitos tardios e as causas foram morte súbita, doença coronariana, pneumonia, septicemia e complicações metabólicas resultantes de diabetes e insuficiência renal crônica, correspondendo a uma incidência de 3,9% ± 1,7% por paciente/ano. A sobrevida atuarial em 9 anos foi 61,5% ± 9,2%, incluindo a mortalidade cirúrgica e a sobrevida atuarial livre de degeneração tissular estrutural primária do conduto biológico foi de 100%. O corrugamento do pericárdio, resultante da incorporação do princípio crimping utilizado nas próteses vasculares sint

  12. Congenital Complete Tracheal Ring in a Neonate: A Case Report

    Directory of Open Access Journals (Sweden)

    Esra ARUN ÖZER

    2017-09-01

    Full Text Available Abnormalities of the upper airway tract lead to congenital high airway obstruction and may complicate neonatal airway management in the delivery room. Congenital complete tracheal rings are a rare and unusual tracheal anomaly, usually presenting in the neonate or infant as respiratory distress. The clinical presentation can vary from almost asymptomatic patients to near-fatal airway obstruction. It may exist as an isolated entity, or in association with other congenital malformations, in particular, cardiac anomalies along with vascular rings and pulmonary slings. Other associated anomalies have also been reported, for example, chromosomal anomalies, malformation of other parts of the respiratory tract, esophagus and skeletal systems. Here, we report an extreme case of VACTERL/TACRD association presented with congenital complete tracheal ring, encephalocele, bilateral radial agenesis with absent thumbs, equinovalgus deformity on right foot, low-set ears and micrognathia.

  13. Análisis del comportamiento mecánico en una sección de la aorta // Mechanical behavior analysis in an aorta section

    Directory of Open Access Journals (Sweden)

    A. González-Martin

    2009-05-01

    Full Text Available La importancia social de las enfermedades arteriales motiva el interés en desarrollar estudios sobreel comportamiento mecánico de las paredes arteriales que aporten información para la prácticamédica, ya que estas enfermedades están fuertemente relacionadas con factores mecánicos comoson los estados de deformación y tensión. El presente trabajo ofrece una metodología para analizarel comportamiento mecánico de una arteria (la aorta. Dicho análisis parte de una geometría realconstruida a partir de imágenes médicas. En la formulación del modelo de elementos finitos seescogió un material con comportamiento no-lineal, con grandes deformaciones, hiperelástico, nohomogéneoy ortótropico. A la hora de analizar los resultados logrados y compararlos con losresultados obtenidos por otros autores no es posible establecer una comparación debido a losdiferentes métodos de ensayo empleados por distintos autores y la dificultad en laexperimentación en arterias humanas, solo es posible establecer zonas criticas en las cuales sepresente algún tipo de enfermedad arterial.Palabras claves: aorta, modelación, elementos finitos (EF, hiperelásticidad.______________________________________________________________________________AbstractThe social importance of the arterial illnesses motivates the interest in developing studies on themechanical behavior of the arterial walls. The medical practice has pointed that these illnesses arestrongly related with mechanical factors, such as states of deformation and tension as other relatedparameters. The present work offers a methodology to analyze the mechanical behavior of anartery (the aorta. This analysis uses a real geometry model that has been built based on medicalimages. In the formulation of the finite elements model the material has been considered with ano-linear behavior, with big deformations, hyperplasic, no-homogeneous and orthotropic. It is notpossible to establish comparisons between the

  14. Prototype moving-ring reactor

    International Nuclear Information System (INIS)

    Smith, A.C. Jr.; Ashworth, C.P.; Abreu, K.E.

    1982-01-01

    We have completed a design of the Prototype Moving-Ring Reactor. The fusion fuel is confined in current-carrying rings of magnetically-field-reversed plasma (Compact Toroids). The plasma rings, formed by a coaxial plasma gun, undergo adiabatic magnetic compression to ignition temperature while they are being injected into the reactor's burner section. The cylindrical burner chamber is divided into three burn stations. Separator coils and a slight axial guide field gradient are used to shuttle the ignited toroids rapidly from one burn station to the next, pausing for 1/3 of the total burn time at each station. D-T- 3 He ice pellets refuel the rings at a rate which maintains constant radiated power

  15. Autumn study on storage rings

    CERN Multimedia

    1974-01-01

    The first two weeks of October have seen storage ring people from accelerator Laboratories throughout the world at CERN to study the fundamental problems of very high energy protonproton colliding beam machines.

  16. Minimal Gromov-Witten rings

    International Nuclear Information System (INIS)

    Przyjalkowski, V V

    2008-01-01

    We construct an abstract theory of Gromov-Witten invariants of genus 0 for quantum minimal Fano varieties (a minimal class of varieties which is natural from the quantum cohomological viewpoint). Namely, we consider the minimal Gromov-Witten ring: a commutative algebra whose generators and relations are of the form used in the Gromov-Witten theory of Fano varieties (of unspecified dimension). The Gromov-Witten theory of any quantum minimal variety is a homomorphism from this ring to C. We prove an abstract reconstruction theorem which says that this ring is isomorphic to the free commutative ring generated by 'prime two-pointed invariants'. We also find solutions of the differential equation of type DN for a Fano variety of dimension N in terms of the generating series of one-pointed Gromov-Witten invariants

  17. Cosmic rings from colliding galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Mitton, S

    1976-11-18

    Research on two ring galaxies has led to the proposal of an interaction model to account for the rings. It is envisaged that this class of galaxy is created when a compact galaxy crashes through the disc of a spiral galaxy. The results of a spectroscopic investigation of the galaxy known as the Cartwheel and of another ring galaxy 11 NZ 4 are discussed. The general picture of ring galaxies which emerges from these studies of a massive starry nucleus with a necklace of emitting gas and some spokes and along the spin axis of the wheel a small companion galaxy that is devoid of interstellar gas. An explanation of these properties is considered.

  18. Ring lasers - a brief history

    Science.gov (United States)

    Klein, Tony

    2017-10-01

    Used these days in inertial navigation, ring lasers are also used in recording the tiniest variations in the Earth's spin, as well in detecting earthquakes and even the drift of continents. How did it all begin?

  19. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  20. Collector ring project at FAIR

    International Nuclear Information System (INIS)

    Dolinskii, A; Blell, U; Dimopoulou, C; Gorda, O; Leibrock, H; Litvinov, S; Laier, U; Schurig, I; Weinrich, U; Berkaev, D; Koop, I; Starostenko, A; Shatunov, P

    2015-01-01

    The collector ring is a dedicated ring for fast cooling of ions coming from separators at the FAIR project. To accommodate optimal technical solutions, a structure of a magnet lattice was recently reviewed and modified. Consequently, more appropriate technical solutions for the main magnets could be adopted. A general layout and design of the present machine is shown. The demanding extraction schemes have been detailed and open design issues were completed. (paper)

  1. Synlig læring

    DEFF Research Database (Denmark)

    Brandsen, Mads

    2017-01-01

    Introduktionen af John Hatties synlig læring i den danske skoleverden møder stadig meget kritik. Mange lærere og pædagoger oplever synlig læring som en tornado, der vil opsuge og ødelægge deres særlige danske udgave af den kontinentale dannelsestænkning, didaktik og pædagogik. Spørgsmålet er om...

  2. The circular RFQ storage ring

    International Nuclear Information System (INIS)

    Ruggiero, A.G.

    1998-01-01

    This paper presents a novel idea of storage ring for the accumulation of intense beams of light and heavy ions at low energy. The new concept is a natural development of the combined features used in a conventional storage ring and an ion trap, and is basically a linear RFQ bend on itself. In summary the advantages are: smaller beam dimensions, higher beam intensity, and a more compact storage device

  3. The Circular RFQ Storage Ring

    International Nuclear Information System (INIS)

    Ruggiero, A. G.

    1999-01-01

    This paper presents a novel idea of storage ring for the accumulation of intense beams of light and heavy ions at low energy. The new concept is a natural development of the combined features of conventional storage rings and ion traps, and is basically a linear RFQ bent on itself. The advantages are: smaller beam dimensions, higher beam intensity, and a more compact storage device

  4. Electrically charged dilatonic black rings

    International Nuclear Information System (INIS)

    Kunduri, Hari K.; Lucietti, James

    2005-01-01

    In this Letter we present (electrically) charged dilatonic black ring solutions of the Einstein-Maxwell-dilaton theory in five dimensions and we consider their physical properties. These solutions are static and as in the neutral case possess a conical singularity. We show how one may remove the conical singularity by application of a Harrison transformation, which physically corresponds to supporting the charged ring with an electric field. Finally, we discuss the slowly rotating case for arbitrary dilaton coupling

  5. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  6. Resonance capture and Saturn's rings

    International Nuclear Information System (INIS)

    Patterson, C.W.

    1986-05-01

    We have assigned the resonances apparently responsible for the stabilization of the Saturn's shepherd satellites and for the substructure seen in the F-ring and the ringlets in the C-ring. We show that Saturn's narrow ringlets have a substructure determined by three-body resonances with Saturn's ringmoons and the sun. We believe such resonances have important implications to satellite formation. 17 refs., 1 fig., 1 tab

  7. Energy spectra of quantum rings.

    Science.gov (United States)

    Fuhrer, A; Lüscher, S; Ihn, T; Heinzel, T; Ensslin, K; Wegscheider, W; Bichler, M

    2001-10-25

    Quantum mechanical experiments in ring geometries have long fascinated physicists. Open rings connected to leads, for example, allow the observation of the Aharonov-Bohm effect, one of the best examples of quantum mechanical phase coherence. The phase coherence of electrons travelling through a quantum dot embedded in one arm of an open ring has also been demonstrated. The energy spectra of closed rings have only recently been studied by optical spectroscopy. The prediction that they allow persistent current has been explored in various experiments. Here we report magnetotransport experiments on closed rings in the Coulomb blockade regime. Our experiments show that a microscopic understanding of energy levels, so far limited to few-electron quantum dots, can be extended to a many-electron system. A semiclassical interpretation of our results indicates that electron motion in the rings is governed by regular rather than chaotic motion, an unexplored regime in many-electron quantum dots. This opens a way to experiments where even more complex structures can be investigated at a quantum mechanical level.

  8. Origem anômala da artéria pulmonar direita em aorta ascendente (hemitruncus Anomalous origin of right pulmonary artery from ascending aorta (hemitruncus

    Directory of Open Access Journals (Sweden)

    Ivan Romero Rivera

    1998-05-01

    Full Text Available A origem da artéria pulmonar direita em aorta ascendente é uma anomalia congênita rara, com poucos casos descritos na literatura. Descrevemos dois casos desta malformação, um associado à interrupção de arco aórtico tipo B. Em ambos, o diagnóstico foi realizado mediante ecocardiografia bidimensional, com confirmação angiográfica em um. A origem da artéria pulmonar direita era próxima à valva aórtica, anomalia patogeneticamente diferente da origem perto da artéria inominada.The origin of the right pulmonary artery from the ascending aorta is a rare congenital anomaly, with very few reports in the literature. We describe two cases of this rare malformation, one of them, associated with interruption of the aortic arch (type B. In both cases, the diagnosis was made by two-dimensional echocardiography, with angiographic confirmation in one of them. The origin of the right pulmonary artery was close to the aortic valve, anomaly pathogenetically distinct from the type that arises close to the innominate artery.

  9. Diagnostic value of the flow profile in the distal descending aorta by phase-contrast magnetic resonance for predicting severe coarctation of the aorta.

    Science.gov (United States)

    Muzzarelli, Stefano; Ordovas, Karen Gomes; Hope, Michael D; Meadows, Jeffery J; Higgins, Charles B; Meadows, Alison Knauth

    2011-06-01

    To compare aortic flow profiles at the level of the proximal descending (PDAo) and distal descending aorta (DDAo) in patients investigated for coarctation of the aorta (CoA), and compare their respective diagnostic value for predicting severe CoA. Diastolic flow decay in the PDAo predicts severe CoA, but flow measurements at this level are limited by flow turbulence, aliasing, and stent-related artifacts. We studied 49 patients evaluated for CoA with phase contrast magnetic resonance imaging (PC-MRI). Parameters of diastolic flow decay in the PDAo and DDAo were compared. Their respective diagnostic value was compared with the standard reference of transcatheter peak gradient ≥20 mmHg. Flow measurement in the PDAo required repeated acquisition with adjustment of encoding velocity or location of the imaging plane in 69% of patients; measurement in the DDAo was achieved in single acquisition in all cases. Parameters of diastolic flow decay in the PDAo and DDAo, including rate-corrected (RC) deceleration time and RC flow deceleration yielded a good correlation (r = 0.78; P RC deceleration time at DDAo (sensitivity 85%, specificity 85%). Characterization of aortic flow profiles at the DDAo offers a quick and reliable noninvasive means of assessing hemodynamically significant CoA. Copyright © 2011 Wiley-Liss, Inc.

  10. Ruptured tuberculous false aneurysm of the abdominal aorta: a case report.

    Science.gov (United States)

    Mechchat, Alae; Lekehal, Brahim; Mesnaoui, Abbes; Ammar, Fannid; Bensaid, Younes

    2011-01-01

    Tuberculous false aneurysm of the aorta is rare and has an unpredictable complication of aneurysm rupture. We report a case of a 32-year old woman who was referred to the Department of Vascular Surgery, Avicenne Hospital for severe abdominal pain. Chest x-ray revealed miliary tuberculosis. Contrast enhanced computed tomography (CT) scan showed a false aortic aneurysm involving the juxtarenal aorta. Antituberculous treatment was started because of high presumption of tuberculosis. Five days later, the patient presented with symptoms of aneurysm rupture. She underwent an emergency a surgical resection of the aneurysm with repair of the aortic wall defect by a Dacron Silver patch. The histopathologic examination of the aortic wall showed features of tuberculosis.

  11. Constriction of juxta-ductal aorta and rapid progression of obstruction in a newborn

    Directory of Open Access Journals (Sweden)

    Awasthy Neeraj

    2010-01-01

    Full Text Available A 13-day-old baby girl presenting with features of congestive cardiac failure was found to have coarctation of the aorta (CoA and patent ductus arteriosus (PDA by echocardiography. Doppler spectral display revealed moderate CoA. Echocardiogram, 12 hours later, showed severe juxtaductal aortic coarctation with spontaneous closure of PDA. This case emphasises the need to keep a close watch on the progress of CoA in the neonatal period, even if the duct has narrowed to a small size thus demonstrating the role of constriction of juxtaductal aorta in pathogenesis of coaractation. Closure of even asmall PDA can cause acute progression CoA in the presence of posterior shelf.

  12. Constriction of juxta-ductal aorta and rapid progression of obstruction in a newborn

    International Nuclear Information System (INIS)

    Awasthy, Neeraj; Tomar, Munesh; Radhakrishnan, Sitaraman; Iyer, Krishna Subramoney

    2010-01-01

    A 13-day-old baby girl presenting with features of congestive cardiac failure was found to have coarctation of the aorta (CoA) and patent ductus arteriosus (PDA) by echocardiography. Doppler spectral display revealed moderate CoA. Echocardiogram, 12 hours later, showed severe juxtaductal aortic coarctation with spontaneous closure of PDA. This case emphasises the need to keep a close watch on the progress of CoA in the neonatal period, even if the duct has narrowed to a small size thus demonstrating the role of constriction of juxtaductal aorta in pathogenesis of coaractation. Closure of even asmall PDA can cause acute progression CoA in the presence of posterior shelf

  13. Plaque of atherosclerosis in aorta: review on atherogenesis, formation of plaque, clinical significance, methods of imaging and treatment; Placa de aterosclerose em aorta: revisao sobre aterogenese, formacao de placa, significado clinco, metodos de imagens e tratamento

    Energy Technology Data Exchange (ETDEWEB)

    Furtado, Rogerio Gomes; Nunes, Colandy G. de Oliveira; Rassi, Junior, Luis; Melato, Luciano Henrique; Turco, Fabio de Paula; Borges, Moises Marcos, E-mail: rogerinhofurtado@gmail.com [Centro de Diagnostico por Imagem (CDI), Goiania, GO (Brazil); Sara, Leonardo [Instituto do Coracao (InCor/FM/USP), Sao Paulo, SP (Brazil)

    2009-04-15

    There is a certain consensus in the literature that the earliest stage of atherogenesis is characterized by the accumulation of spongy cells in the region of the intimal artery. Risk factors such as arterial hypertension, smoking, diabetes mellitus, hypercholesterolemia, male gender and advanced age predispose a person to the formation of plaques in the coronaries and aorta. A greater number of acute coronary events as well as strokes have been observed in people with these risk factors. Strokes are the third cause of death in the USA, with about 40% of the cases being of cryptogenic origin. Since 1989 the atheroma plaques which develop in the thoracic aorta have been considered to be responsible for cerebral and peripheral strokes which were previously considered cryptogenic because imaging techniques such as electrocardiogram transesophageal, computerized tomogram, nuclear magnetic angio-resonance have visualized and characterized the lesions with plaques of arteriosclerosis in the thoracic aorta. The authors of this article made a systematic review in the PUBMED about arteriosclerosis in the aorta and its diagnostic methods. This review includes the physiopathology of the formation of atheroma to the aorta and its consequences, diagnostic methods such as echo transesophageal, computerized tomogram and angio resonance, as well as the advantages and disadvantages of each method of identification of the lesions. An analysis of the clinical significance of the size, form and location of the atheroma plaques in the thoracic aorta were made based on clinical studies, as well as their treatment with anticoagulants, antiplatelet and drugs to reduce cholesterol. (author)

  14. Estimation of prenatal aorta intima-media thickness from ultrasound examination

    International Nuclear Information System (INIS)

    Veronese, E; Tarroni, G; Grisan, E; Visentin, S; Cosmi, E; Linguraru, M G

    2014-01-01

    Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and children, in recent years the measurement of abdominal and carotid artery thickness has gained a growing appeal. Nevertheless, no computer aided method has been proposed for the analysis of prenatal vessels from ultrasound data, yet. To date, these measurements are being performed manually on ultrasound fetal images by skilled practitioners. The aim of the presented study is to introduce an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from routine third trimester ultrasonographic fetal data. The algorithm locates the aorta, then segments it and, by modeling the arterial wall longitudinal sections by means of a gaussian mixture, derives a set of measures of the aorta diameter (aDiam) and of the intima-media thickness (aIMT). After estimating the cardiac cycle, the mean diameter and the aIMT at the end-diastole phase are computed. Considering the aIMT value for each subject, the correlation between automatic and manual end-diastolic aIMT measurements is 0.91 in a range of values 0.44-1.10 mm, corresponding to both normal and pathological conditions. The automatic system yields a mean relative error of 19%, that is similar to the intra-observer variability (14%) and much lower that the inter-observer variability (42%). The correlation between manual and automatic measurements and the small error confirm the ability of the proposed system to reliably estimate aIMT values in prenatal ultrasound sequences, reducing measurement variability and suggesting that it can be used for an automatic assessment of aIMT. (paper)

  15. Clinical evaluation of atherosclerosis and mechanical properties of the thoracic aorta

    International Nuclear Information System (INIS)

    Saiki, Atsushi

    1991-01-01

    To evaluate the aortic wall atherosclerosis, X-ray CT and ECG gated radionuclide angiography were performed in 25 subjects. They were classified into 17 normotensive group (N) and 8 hypertensive group (HT). The time-activity curve was generated using radionuclide angiography in the portion of the thoracic aorta. The aortic wall distensibility was expressed as 100ΔV/V 0 / PP, where ΔV was difference between maximum and minimum (V 0 ) counts of the aorta, and PP was pulse pressure. The degree of the aortic wall atherosclerosis was evaluated by X-ray CT. The aortic wall CT-score was calculated from the CT-scores measured whithin the region of interest of the other margin of the aorta and of the background by X-ray CT. There was a significant correlation between aortic wall CT-score and systolic blood pressure (r=0.59, p<0.01) or aortic wall distensibility (r=-0.74, p<0.01)), but no correlation existed between aortic wall CT-score and diastolic blood pressure (r=0.11, p:NS). The aortic wall distensibility was higher and the aortic wall CT-score was lower in N-group than in HT-group, whereas there was no difference of the radius of the aorta between both groups. These results suggest that the aortic wall atherosclerosis advanced progressively in hypertensive patients and systolic blood pressure was a good predictor of the degree of the aortic atherosclerosis. (author)

  16. Mechanical contribution of lamellar and interlamellar elastin along the mouse aorta.

    Science.gov (United States)

    Clark, T E; Lillie, M A; Vogl, A W; Gosline, J M; Shadwick, R E

    2015-10-15

    The mechanical properties of aortic elastin vary regionally, but the microstructural basis for this variation is unknown. This study was designed to identify the relative contributions of lamellar and interlamellar elastin to circumferential load bearing in the mouse thoracic and abdominal aortas. Forces developed in uniaxial tests of samples of fresh and autoclaved aorta were correlated with elastin content and morphology obtained from histology and multiphoton laser scanning microscopy. Autoclaving should render much of the interlamellar elastin mechanically incompetent. In autoclaved tissue force per unit sample width correlated with lamellar elastin content (P≪0.001) but not total elastin content. In fresh tissue at low strain where elastin dominates the mechanical response, forces were higher than in the autoclaved tissue, but force did not correlate with total elastin content. Therefore although interlamellar elastin likely contributed to the stiffness in the fresh aorta, its contribution appeared not in proportion to its quantity. In both fresh and autoclaved tissue, elastin stiffness consistently decreased along the abdominal aorta, a key area for aneurysm development, and this difference could not be fully accounted for on the basis of either lamellar or total elastin content. These findings are relevant to the development of mathematical models of arterial mechanics, particularly for mouse models of arterial diseases involving elastic tissue. In microstructural based models the quantity of each mural constituent determines its contribution to the total response. This study shows elastin's mechanical response cannot necessarily be accounted for on the basis of fibre quantity, orientation, and modulus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Melatonin effect on hypertension and nitric oxide balance in the heart and aorta

    Czech Academy of Sciences Publication Activity Database

    Pecháňová, Olga; Paulis, L.; Zicha, Josef; Kuneš, Jaroslav; Šimko, F.

    2006-01-01

    Roč. 24, č. S6 (2006), s. 395-395 ISSN 0263-6352. [Scientific Meeting of the International Society of Hypertension /21./. 15.10.2006-19.10.2006, Fukuoka] Grant - others:VEGA(SK) 2/6148/26 Institutional research plan: CEZ:AV0Z50110509 Keywords : melatonin * nitric oxide balance * hypertension * SHR and WKY rat * heart and aorta Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  18. Effects of the pregnant uterus on the abdominal aorta and its branches

    Energy Technology Data Exchange (ETDEWEB)

    Ohlson, L [Karolinska Sjukhuset, Stockholm (Sweden)

    1978-01-01

    The pregnant uterus was found to exert pressure upon the lumbar region with a maximum over the midline of the lordosis and diminishing laterally. Those parts of the arterial system formed by the aorta and its dorsal branches and displaceable at autopsy, were accordingly dislodged by the uterus, whereas the fixed parts were compressed. The pressure effects extended cranially during pregnancy. Symptoms of compression can be relieved by avoiding supine and prone positions.

  19. Effects of the pregnant uterus on the abdominal aorta and its branches

    International Nuclear Information System (INIS)

    Ohlson, L.

    1978-01-01

    The pregnant uterus was found to exert pressure upon the lumbar region with a maximum over the midline of the lordosis and diminishing laterally. Those parts of the arterial system formed by the aorta and its dorsal branches and displaceable at autopsy, were accordingly dislodged by the uterus, whereas the fixed parts were compressed. The pressure effects extended cranially during pregnancy. Symptoms of compression can be relieved by avoiding supine and prone positions. (Auth.)

  20. Coarctation of the Aorta in Infants Under One Year of Age

    African Journals Online (AJOL)

    1974-03-02

    Mar 2, 1974 ... (trisomy 16 - 18). Total. 20. 2. 3. 28. 48. 2. 3. From Table III the residual gradients of 12 out of 13 cases operated on, can be seen. The patient with associated tubular hypoplasia, who had nothing done to the aorta at operation, is excluded. Six (50%) had gradients of 20 mmHg, or more. Only 2 of these had ...

  1. Endovascular Repair of a Pseudoaneurysm of the Abdominal Aorta Secondary to Translumbar Aortography

    International Nuclear Information System (INIS)

    Mir, Naheed; Nunzio, Mario De; Pollock, John G

    2006-01-01

    This report describes an incidental finding of a pseudoaneurysm of the abdominal aorta on a computed tomography (CT) renal angiogram during investigation of chronic renal failure in a 73-year-old man. The patient had undergone a translumbar aortogram 20 years previously. An increase in the size of the aneurysm by 7 mm over 6 months prompted treatment and the aneurysm underwent successful endovascular repair with a custom-made stent-graft

  2. Three-dimensional display of the heart, aorta, lungs, and airway using CT

    International Nuclear Information System (INIS)

    Fram, E.K.; Godwin, J.D.; Putman, C.E.

    1982-01-01

    In previous studies of human anatomy, three-dimensional display of CT data has required laborious manual boundary tracking, except for high-contrast structures such as the spine. Automated boundary tracking techniques have been extended so that they can function well for both high-contrast and soft-tissue interfaces. These methods have been applied to the in vivo study of human lungs, heart, aorta, and larynx in this paper

  3. Comparison of Aorta-sacral Promontory Distance with Age and BMI in Female Patients Undergoing CT

    OpenAIRE

    Sneha Mary Varghese; Suresh Sukumar; Abhimanyu Pradhan

    2017-01-01

    Introduction: Sacral colpopexy is the gold standard procedure for pelvic organ prolapse. During sacral colpopexy, various complications such as haemorrhage can occur. Careful dissection of presacral space is essential to minimize complications. Aim: The aim of the study was to compare patient age and Body Mass Index (BMI) with Computed Tomography (CT) measured aorta-sacral promontory distance. Materials and Methods: From 172 samples data such as age and BMI of female patients aged 18 ye...

  4. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  5. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.

    Science.gov (United States)

    Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-12-01

    The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.

  6. Changes in the Severity and Injury Sources of Thoracic Aorta Injuries due to Vehicular Crashes

    OpenAIRE

    Ryb, Gabriel; Dischinger, Patricia; Kerns, Timothy; Burch, Cynthia; Rabin, Joseph; Ho, Shiu

    2013-01-01

    Research using the National Automotive Sampling System-Crashworthiness Data System (NASS-CDS) suggested a decreased adjusted risk of thoracic aorta injuries (TAI) for newer vehicles during near-side crashes and an increased adjusted TAI risk during frontal crashes. This study attempted to explore possible explanations of these findings. Adult front seat occupants in the Crash Injury Research and Engineering Network (CIREN) database through June 2012 were studied. TAI cases were compared with ...

  7. Accretion in Saturn's F Ring

    Science.gov (United States)

    Meinke, B. K.; Esposito, L. W.; Stewart, G.

    2012-12-01

    Saturn's F ring is the solar system's principal natural laboratory for direct observation of accretion and disruption processes. The ring resides in the Roche zone, where tidal disruption competes with self-gravity, which allows us to observe the lifecycle of moonlets. Just as nearby moons create structure at the B ring edge (Esposito et al. 2012) and the Keeler gap (Murray 2007), the F ring "shepherding" moons Prometheus and Pandora stir up ring material and create observably changing structures on timescales of days to decades. In fact, Beurle et al (2010) show that Prometheus makes it possible for "distended, yet gravitationally coherent clumps" to form in the F ring, and Barbara and Esposito (2002) predicted a population of ~1 km bodies in the ring. In addition to the observations over the last three decades, the Cassini Ultraviolet Imaging Spectrograph (UVIS) has detected 27 statistically significant features in 101 occultations by Saturn's F ring since July 2004. Seventeen of those 27 features are associated with clumps of ring material. Two features are opaque in occultation, which makes them candidates for solid objects, which we refer to as Moonlets. The 15 other features partially block stellar signal for 22 m to just over 3.7 km along the radial expanse of the occultation. Upon visual inspection of the occultation profile, these features resemble Icicles, thus we will refer to them as such here. The density enhancements responsible for such signal attenuations are likely due to transient clumping of material, evidence that aggregations of material are ubiquitous in the F ring. Our lengthy observing campaign reveals that Icicles are likely transient clumps, while Moonlets are possible solid objects. Optical depth is an indicator of clumping because more-densely aggregated material blocks more light; therefore, it is natural to imagine moonlets as later evolutionary stage of icicle, when looser clumps of material compact to form a feature that appears

  8. Double acting stirling engine piston ring

    Science.gov (United States)

    Howarth, Roy B.

    1986-01-01

    A piston ring design for a Stirling engine wherein the contact pressure between the piston and the cylinder is maintained at a uniform level, independent of engine conditions through a balancing of the pressure exerted upon the ring's surface and thereby allowing the contact pressure on the ring to be predetermined through the use of a preloaded expander ring.

  9. Study for ILC Damping Ring at KEKB

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, J.W.; Fukuma, H.; Kanazawa, K.I.; Koiso, H.; Masuzawa, M.; Ohmi, Kazuhito; Ohnishi, Y.; Oide, Katsunobu; Suetsugu, Y.; Tobiyama, M.; /KEK, Tsukuba; Pivi, M.; /SLAC

    2011-11-04

    ILC damping ring consists of very low emittance electron and positron storage rings. It is necessary for ILC damping ring to study electron cloud effects in such low emittance positron ring. We propose a low emittance operation of KEKB to study the effects.

  10. Morphological description of collateral branches from the abdominal aorta of lesser anteater (Tamandua tetradactyla

    Directory of Open Access Journals (Sweden)

    Breno Costa Macedo

    2013-03-01

    Full Text Available Tamandua tetradactyla, Xenarthra, is a native species from South America which, due to the few number of studies on its biology, still has many unknown aspects in its morphology. Taking into account the importance of morphological data for various studies, this paper aimed to elucidate the branching of the abdominal aorta in this species to foster the development of further studies. To do this, 4 specimens were used, 2 male and 2 female, all young, from the Bauxite Mine – Paragominas, Para, Brazil, donated after death due to running over to the Animal Morphology Research Laboratory (LaPMA of Universidade Federal Rural da Amazonia (UFRA. The arterial system was filled with contrasted latex and the animals were fixed in a formaldehyde solution (10%, and then dissected, in order to evidence the abdominal aorta and its collateral branches. The parietal branches consisted of 1 pair of caudal phrenic arteries, 2 pairs of intercostal arteries, and 3 pairs of lumbar arteries. Among the visceral branches, stood out: celiac artery; cranial mesenteric artery; adrenal arteries; renal arteries; caudal mesenteric artery; and external, internal, and median sacral iliac arteries, formed from the final portion of the abdominal aorta. Testicular and ovarian arteries originated from the renal arteries, differing from that described in various species.

  11. Aneurisma de aorta com ruptura para esôfago Aortic aneurysm rupture into the esophagus

    Directory of Open Access Journals (Sweden)

    Christiano da Silveira de Barcellos

    2008-12-01

    Full Text Available Apresentamos o caso de uma paciente portadora de aneurisma de aorta descendente com ruptura para o esôfago que, após aortoplastia com interposição de tubo de dacron e rafia da laceração esofágica, evoluiu com fístula esôfago pleural no terceiro dia pós-operatório. A paciente necessitou de reintervenção e cuidados intensivos, reabilitando-se adequadamente. A propósito deste caso incomum e do aprendizado adquirido no seu manejo, revisamos a literatura a fim de discutir a melhor alternativa de correção desta rara e, freqüentemente, fatal forma de apresentação das doenças da aorta.We present the case of a patient with a descending aorta aneurysm rupture into the esophagus, which, after aortoplasty with Dacron tube interposition and suture of esophageal laceration, developed a pleural-esophagus fistula on the 3rd postoperative day. She needed re-intervention and intensive care, followed by adequate recovery. Considering this unusual case and the knowledge acquired through its management, we reviewed the literature in order to discuss the best alternative for the correction of this rare and often fatal form of presentation of aortic diseases.

  12. Congenital diseases of the thoracic aorta. Role of MRI and MRA

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Renzulli, Matteo; Palombara, Cesare la; Fattori, Rossella

    2006-01-01

    Aortic malformations may be associated with other congenital heart abnormalities or may present independently, as incidental findings in asymptomatic patients. For more than 30 years, conventional imaging techniques for detection and assessment of congenital anomalies of the aorta have been chest X-ray, echocardiography and angiography. In recent times, considerable interest in congenital aortic diseases has been shown, due to technical progresses of noninvasive imaging modalities. Among them, magnetic resonance imaging (MRI) almost certainly offers the greatest advantages, especially in young patients in which a radiation exposure must be avoided as much as possible. MRI provides an excellent visualization of vascular structures with a wide field of view, well suited for evaluation of the thoracic aorta malformations. With the implementation of magnetic resonance angiography (MRA) it is also possible to depict any relationship with supra-aortic or mediastinal vessels. Phase contrast technique allows identification of the hemodynamic significance of the aortic alteration. Some technical considerations, which include fast spin-echo, gradient-echo and, especially, MRA techniques with phase-contrast and contrast enhanced methods, are discussed and applied in the evaluation of congenital thoracic aorta diseases. (orig.)

  13. Lung, aorta, and platelet metabolism of 14C-arachidonic acid in vitamin E deficient rats

    International Nuclear Information System (INIS)

    Valentovic, M.A.; Gairola, C.; Lubawy, W.C.

    1982-01-01

    14 C-arachidonic acid metabolism was determined in aortas, platelets, and perfused lungs from rats pair fed a basal diet supplemented with 0 or 100 ppm vitamin E for 11 weeks. Spontaneous erythrocyte hemolysis tests showed 92% and 8% hemolysis for the 0 and 100 ppm vitamin E groups, respectively. Elevated lung homogenate levels of malonaldehyde in the 0 ppm group confirmed its deficient vitamin E status. Aortas from the vitamin E deficient group synthesized 54% less prostacyclin than aortas from the supplemented group (p less than 0.05). Although thromboxane generation by platelets from the vitamin E deficient group exhibited a 37% increase, this difference was not statistically significant compared to the supplemented animals. Greater amounts of PGE2, PGF2 alpha, TXB2, and 6-keto-PGF1 alpha were obtained in albumin buffer perfusates from lungs of vitamin E deficient rats than in those from supplemented rats. Significant differences (p less than 0.05) were noticed, however, only for PGE2 and PGF2 alpha. These studies indicate that vitamin E quantitatively alters arachidonic acid metabolism in aortic and lung tissue but its effect on thromboxane synthesis by platelets is less marked

  14. Aorta Structural Alterations in Term Neonates: The Role of Birth and Maternal Characteristics

    Directory of Open Access Journals (Sweden)

    Marco Matteo Ciccone

    2013-01-01

    Full Text Available Aim. To evaluate the influence of selected maternal and neonatal characteristics on aorta walls in term, appropriately grown-for-gestational age newborns. Methods. Age, parity, previous abortions, weight, height, body mass index before and after delivery, smoking, and history of hypertension, of diabetes, of cardiovascular diseases, and of dyslipidemia were all assessed in seventy mothers. They delivered 34 males and 36 females healthy term newborns who underwent ultrasound evaluation of the anteroposterior infrarenal abdominal aorta diameter (APAO, biochemical profile (glucose, insulin, total cholesterol, HDL and LDL cholesterol, triglycerides, fibrinogen, and D-dimers homeostasis model assessment [HOMAIR]index, and biometric parameters. Results. APAO was related to newborn length (r=+0.36; P=0.001, head circumference (r=+0.37; P=0.001, gestational age (r=+0.40, P=0.0005, HOMA index (r=+0.24; P=0.04, and D-dimers (r=+0.33, P=0.004. Smoke influenced APAO values (odds ratio: 1.80; confidence interval 95%: 1.05–3.30, as well as diabetes during pregnancy (r=+0.42, P=0.0002. Maternal height influenced neonatal APAO (r=+0.47, P=0.00003. Multiple regression analysis outlined neonatal D-dimers as still significantly related to neonatal APAO values. Conclusions. Many maternal and neonatal characteristics could influence aorta structures. Neonatal D-dimers are independently related to APAO.

  15. Increased albumin permeation in eyes, aorta, and kidney of hypertensive rats fed galactose

    International Nuclear Information System (INIS)

    Tilton, R.G.; LaRose, L.; Chang, K.; Weigel, C.J.; Williamson, J.R.

    1986-01-01

    These experiments were undertaken to determine whether ingestion of galactose increases albumin permeation in the vasculature of hypertensive rats. 50% dextrin (control) or 50% galactose diets were fed to unilaterally nephrectomized, male Sprague-Dawley rats weighing 200 g. Hypertension (systolic pressure >175 mmHg) was induced by weekly IM injections of 25 mg/kg DOCA and 1% saline drinking water; 3 months later 125 I-albumin permeation was assessed in whole eyes, aorta and kidneys. 125 I-albumin permeation was significantly increased in all 3 tissues of hypertensive rats (n = 9) vs controls (n = 9): aorta (3.30 +/- 0.19 (SD) vs 2.87 +/- 0.14), eye (3.15 +/- 0.14 vs 2.59 +/- 0.11), and kidney (6.58 +/- 0.63 vs 3.85 +/- 0.50). Albumin permeation was increased still further in hypertensive rats fed the galactose diet (n = 8): aorta (3.75 +/- 0.38), eye (3.82 +/- 0.17), and kidney (10.74 +/- 3.13). Hypertension +/- galactose feeding had no effect on albumin permeation in lung, skin, or brain. These findings indicate that: (1) hypertension increases albumin permeation in vessels affected by diabetic vascular diseases, and 2) hypertension-induced increases in albumin permeation are increased still further by galactose ingestion, presumably mediated by imbalances in polyol/insitol metabolism (analogous to those induced by diabetes) independent of hyperglycemia and/or insulinopenia

  16. Retained guidewire penetrating through the aorta into the thorax: an unusual cause of recurrent bilateral pneumothorax.

    Science.gov (United States)

    Kim, YongHun; Yu, JunSik; Kim, YoHan; Lee, WooSurng

    2016-01-01

    Although numerous complications of the Seldinger technique have been reported in the literature, only a few complications are related to guidewires. We here report a case of a patient with a guidewire lost and retained in the aorta during vertebral artery stenting. Unfortunately, the guidewire in the aorta was not detected for 5 years, and it penetrated through the aorta into the left thorax, leading to recurrent left pneumothorax. No physician identified the wandering guidewire in the left thorax, and the recurrent left pneumothorax was only managed with closed thoracostomy drainage several times. After 4 months, the patient presented to our hospital with repeated severe chest pain, and newly developed right pneumothorax was diagnosed on chest X-rays. We meticulously evaluated the radiological findings of the other hospitals to identify the cause of the recurrent pneumothorax and discovered that the lost and wandering guidewire had crossed over from the left to the right thorax through the anterior mediastinum. The guidewire was identified as the cause of the recurrent bilateral pneumothorax, and the patient was successfully treated with video-assisted thoracoscopic surgery without any events. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Thoracic and abdominal aortas stiffen through unique extracellular matrix changes in intrauterine growth restricted fetal sheep.

    Science.gov (United States)

    Dodson, R Blair; Rozance, Paul J; Petrash, Carson C; Hunter, Kendall S; Ferguson, Virginia L

    2014-02-01

    Intrauterine growth restriction (IUGR) is a fetal complication of pregnancy epidemiologically linked to cardiovascular disease in the newborn later in life. However, the mechanism is poorly understood with very little research on the vascular structure and function during development in healthy and IUGR neonates. Previously, we found vascular remodeling and increased stiffness in the carotid and umbilical arteries, but here we examine the remodeling and biomechanics in the larger vessels more proximal to the heart. To study this question, thoracic and abdominal aortas were collected from a sheep model of placental insufficiency IUGR (PI-IUGR) due to exposure to elevated ambient temperatures. Aortas from control (n = 12) and PI-IUGR fetuses (n = 10) were analyzed for functional biomechanics and structural remodeling. PI-IUGR aortas had a significant increase in stiffness (P fetal vascular remodeling in PI-IUGR may set the stage for possible altered growth and development and help to explain the pathophysiology of adult cardiovascular disease in previously IUGR individuals.

  18. Multiple Thromboembolic Cerebral Infarctions from the Aorta in a Patient with Churg-Strauss Syndrome.

    Science.gov (United States)

    Okada, Hideo

    2017-02-01

    Ischemic stroke is a rare complication of Churg-Strauss syndrome (CSS) and its pathogenesis has not been well clarified yet. We report a case of cerebral infarction in a patient with CSS due to embolism from a thrombus on the wall of the aorta. A 39-year-old man had multiple cerebral infarctions with symptoms of mild left hemiparesis and reduced vision. He was clinically diagnosed to have CSS based on remarkable eosinophilia, history of asthma, sinusitis, pulmonary infiltrates, and histologically proven extravascular eosinophilic infiltrates in the specimen of gastric mucosa. Cerebral angiography did not show any stenotic lesions in cerebral arteries. A thrombus was detected on the wall of the aorta by transesophageal echocardiography, which was considered as the source of embolism. The thrombus resolved on follow-up examination 3 months after the onset of the stroke. This is the first case report on cerebral infarction caused by aortogenic thromboembolism in a CSS patient. Other than cerebral vasculitis, embolism from cardiovascular system, including the wall of the aorta, is a possible cause of cerebral infarctions in a CSS patient. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  19. Thymoquinone protects end organs from abdominal aorta ischemia/reperfusion injury in a rat model

    Directory of Open Access Journals (Sweden)

    Mehmet Salih Aydin

    2015-02-01

    Full Text Available Introduction: Previous studies have demonstrated that thymoquinone has protective effects against ischemia reperfusion injury to various organs like lungs, kidneys and liver in different experimental models. Objective: We aimed to determine whether thymoquinone has favorable effects on lung, renal, heart tissues and oxidative stress in abdominal aorta ischemia-reperfusion injury. Methods: Thirty rats were divided into three groups as sham (n=10, control (n=10 and thymoquinone (TQ treatment group (n=10. Control and TQ-treatment groups underwent abdominal aorta ischemia for 45 minutes followed by a 120-min period of reperfusion. In the TQ-treatment group, thymoquinone was given 5 minutes. before reperfusion at a dose of 20 mg/kg via an intraperitoneal route. Total antioxidant capacity, total oxidative status (TOS, and oxidative stress index (OSI in blood serum were measured and lung, kidney, and heart tissue histopathology were evaluated with light microscopy. Results: Total oxidative status and oxidative stress index activity in blood samples were statistically higher in the control group compared to the sham and TQ-treatment groups (P<0.001 for TOS and OSI. Control group injury scores were statistically higher compared to sham and TQ-treatment groups (P<0.001 for all comparisons. Conclusion: Thymoquinone administered intraperitoneally was effective in reducing oxidative stress and histopathologic injury in an acute abdominal aorta ischemia-reperfusion rat model.

  20. Computed Tomography of the complications of prosthetic surgery of the abdominal aorta

    International Nuclear Information System (INIS)

    Giovagnorio, Francesco; Andreoli, Chiara; De Cicco, Maria Luisa

    1997-01-01

    Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7± 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT confirmed its important role in the study of the complications of prosthetic aortic surgery, despite its know poor specificity in the demonstration of the aorta in the first 2-3 months postoperatively, in the initial stages of infection and in the diagnosis of aorta-enteric fistulas

  1. Pathomorphological changes of aorta in fetuses and newborns exposed to experimental maternal escherichiosis

    Directory of Open Access Journals (Sweden)

    Vladimir Markovskyi

    2018-04-01

    Full Text Available Intrauterine infections occupy a leading place in the perinatal mortality structure. The aim of this study was to identify the morphological features of the aorta in progenies born from mothers with subacute prolonged infectious and inflammatory process. Two experimental studies were performed on WAG line laboratory rats. The comparison group consisted of newborns died due to acute postnatal hypoxia. The main group included fetuses and newborns born from Escherichia coli infected mothers. The differences between the vessels of two study groups were not observed in macroscopic examination. In the group of progenies born from infected mothers, the average thickness of the aorta increased in comparison with the group under hypoxia influence, due to the inner and middle membranes, which can be interpreted as the sclerotic changes development. There was tunica adventitia volume increase in the group with hypoxia, which can be explained by edema caused by increased vascular permeability. Morphological signs of endothelial dysfunction were found in both study groups, which were expressed in the endotheliocytes flattening with their subsequent desquamation more pronounced in the group with hypoxia. It is apparently related to the process severity. There is a violation of the elastic and collagen fibers ratio towards the second in the vessel wall under the hypoxia influence, which reduces the elastic properties of the aorta.

  2. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  3. Manipulation of vortex rings for flow control

    International Nuclear Information System (INIS)

    Toyoda, Kuniaki; Hiramoto, Riho

    2009-01-01

    This paper reviews the dynamics of vortex rings and the control of flow by the manipulation of vortex rings. Vortex rings play key roles in many flows; hence, the understanding of the dynamics of vortex rings is crucial for scientists and engineers dealing with flow phenomena. We describe the structures and motions of vortex rings in circular and noncircular jets, which are typical examples of flows evolving into vortex rings. For circular jets the mechanism of evolving, merging and breakdown of vortex rings is described, and for noncircular jets the dynamics of three-dimensional deformation and interaction of noncircular vortex rings under the effect of self- and mutual induction is discussed. The application of vortex-ring manipulation to the control of various flows is reviewed with successful examples, based on the relationship between the vortex ring dynamics and the flow properties. (invited paper)

  4. Effects of intraoperative electron irradiation in the dog on cell turnover in intact and surgically-anastomosed aorta and intestine

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Morrow, B.M.; Travis, E.L.; Tepper, J.; Merkel, A.B.; Kranda, K.; Terrill, R.

    1983-01-01

    Adults dogs were subjected to laparotomy and intraoperative electron irradiation after division and reanastomosis of aorta or after construction of a blind loop of small intestine having a transverse suture line and an end-to-side anastomosis. Dogs received intraoperative irradiation of both intact and anastomosed aorta or intestine in doses of 0, 2000, 3000, or 4500 rad. Animals were sacrificed at seven days or three months following treatment. At 24 hours prior to sacrifice, dogs received 5 mCi tritiated thymidine intravenously. Irradiated and non-irradiated segments of aorta and small intestine, including intact and anastomotic regions, were analyzed for tritiated thymidine incorporation and were subjected to autoradiography. Incorporation studies showed diminution in tritiated thymidine uptake by irradiated portions of aorta and small intestine, in both intact and anastomotic regions. Autoradiograms revealed that irradiated areas of intact or anastomotic aorta or intestine had diminished labeling of stromal cells, suggesting a lowered cell proliferative capacity of irradiated tissue compared to non-irradiated portions. Inflammatory cells showed similar labeling indices in irradiated and non-irradiated tissues, both intact and surgically-manipulated, suggesting that irradiation does not significantly affect a subsequent local inflammatory response. Radiation-induced decreases in tritiated thymidine incoporation in irradiated aorta and small intestine were generally more marked at seven days than at three months following irradiation, suggesting that radiation-induced depression of cell turnover rates decreases with time

  5. Primary Signet-Ring Cell Carcinoma of the Urinary Bladder Successfully Managed with Radical Cystectomy in a Young Patient

    Directory of Open Access Journals (Sweden)

    Farzad Allameh

    2017-01-01

    Full Text Available Primary signet-ring cell adenocarcinoma of bladder is a rare neoplasm, usually seen in middle age adults. We report the case of an 18-year-old man who presented with intermittent gross hematuria. Computed tomography imaging showed multifilling defects in the bladder. The patient underwent a transurethral resection of the bladder tumor. Histological findings were consistent with poorly differentiated mixed mucinous and signet-ring cell adenocarcinoma. We ruled out other possible origins of tumor by gastrointestinal endoscopy and colonoscopy. The patient was treated with radical cystectomy with prostate and seminal vesicle sparing technique and orthotopic diversion using “W” ileum pouch with pelvic lymphadenectomy to the bifurcation of the aorta was done. Six-month follow-up of patient showed normal conditions without metastatic spread or any recurrence.

  6. Pure subrings of the rings

    International Nuclear Information System (INIS)

    Tsarev, Andrei V

    2009-01-01

    Pure subrings of finite rank in the Z-adic completion of the ring of integers and in its homomorphic images are considered. Certain properties of these rings are studied (existence of an identity element, decomposability into a direct sum of essentially indecomposable ideals, condition for embeddability into a csp-ring, etc.). Additive groups of these rings and conditions under which these rings are subrings of algebraic number fields are described. Bibliography: 12 titles.

  7. Primitivity and weak distributivity in near rings and matrix near rings

    International Nuclear Information System (INIS)

    Abbasi, S.J.

    1993-08-01

    This paper shows the structure of matrix near ring constructed over a weakly distributive and primative near ring. It is proved that a weakly distributive primitive near ring is a ring and the matrix near rings constructed over it is also a bag. (author). 14 refs

  8. Ring wormholes via duality rotations

    Directory of Open Access Journals (Sweden)

    Gary W. Gibbons

    2016-09-01

    Full Text Available We apply duality rotations and complex transformations to the Schwarzschild metric to obtain wormhole geometries with two asymptotically flat regions connected by a throat. In the simplest case these are the well-known wormholes supported by phantom scalar field. Further duality rotations remove the scalar field to yield less well known vacuum metrics of the oblate Zipoy–Voorhees–Weyl class, which describe ring wormholes. The ring encircles the wormhole throat and can have any radius, whereas its tension is always negative and should be less than −c4/4G. If the tension reaches the maximal value, the geometry becomes exactly flat, but the topology remains non-trivial and corresponds to two copies of Minkowski space glued together along the disk encircled by the ring. The geodesics are straight lines, and those which traverse the ring get to the other universe. The ring therefore literally produces a hole in space. Such wormholes could perhaps be created by negative energies concentrated in toroidal volumes, for example by vacuum fluctuations.

  9. HYPERAUTOFLUORESCENT RING IN AUTOIMMUNE RETINOPATHY

    Science.gov (United States)

    LIMA, LUIZ H.; GREENBERG, JONATHAN P.; GREENSTEIN, VIVIENNE C.; SMITH, R. THEODORE; SALLUM, JULIANA M. F.; THIRKILL, CHARLES; YANNUZZI, LAWRENCE A.; TSANG, STEPHEN H.

    2015-01-01

    Purpose To report the presence of a hyperautofluorescent ring and corresponding spectral-domain optical coherence tomography (SD-OCT) features seen in patients with autoimmune retinopathy. Methods All eyes were evaluated by funduscopic examination, full-fleld electroretinography, fundus autofluorescence, and SD-OCT. Further confirmation of the diagnosis was obtained with immunoblot and immunohistochemistry testing of the patient’s serum. Humphrey visual fields and microperimetry were also performed. Results Funduscopic examination showed atrophic retinal pigment epithelium (RPE) associated with retinal artery narrowing but without pigment deposits. The scotopic and photopic full-field electroretinograms were nondetectable in three patients and showed a cone–rod pattern of dysfunction in one patient. Fundus autofluorescence revealed a hyperautofluorescent ring in the parafoveal region, and the corresponding SD-OCT demonstrated loss of the photoreceptor inner segment–outer segment junction with thinning of the outer nuclear layer from the region of the hyperautofluorescent ring toward the retinal periphery. The retinal layers were generally intact within the hyperautofluorescent ring, although the inner segment–outer segment junction was disrupted, and the outer nuclear layer and photoreceptor outer segment layer were thinned. Conclusion This case series revealed the structure of the hyperautofluorescent ring in autoimmune retinopathy using SD-OCT. Fundus autofluorescence and SD-OCT may aid in the diagnosis of autoimmune retinopathy and may serve as a tool to monitor its progression. PMID:22218149

  10. Estimation of prenatal aorta intima-media thickness from ultrasound examination

    Science.gov (United States)

    Veronese, E.; Tarroni, G.; Visentin, S.; Cosmi, E.; Linguraru, M. G.; Grisan, E.

    2014-10-01

    Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and children, in recent years the measurement of abdominal and carotid artery thickness has gained a growing appeal. Nevertheless, no computer aided method has been proposed for the analysis of prenatal vessels from ultrasound data, yet. To date, these measurements are being performed manually on ultrasound fetal images by skilled practitioners. The aim of the presented study is to introduce an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from routine third trimester ultrasonographic fetal data. The algorithm locates the aorta, then segments it and, by modeling the arterial wall longitudinal sections by means of a gaussian mixture, derives a set of measures of the aorta diameter (aDiam) and of the intima-media thickness (aIMT). After estimating the cardiac cycle, the mean diameter and the aIMT at the end-diastole phase are computed. Considering the aIMT value for each subject, the correlation between automatic and manual end-diastolic aIMT measurements is 0.91 in a range of values 0.44-1.10 mm, corresponding to both normal and pathological conditions. The automatic system yields a mean relative error of 19%, that is similar to the intra-observer variability (14%) and much lower that the inter-observer variability (42%). The correlation between manual and automatic measurements and the small error confirm the ability of the proposed system to reliably estimate aIMT values in prenatal ultrasound sequences, reducing measurement variability and suggesting that it can be used for an automatic assessment of aIMT. Preliminary results have been presented in E Veronese, E Cosmi, S Visentin, E Grisan: 'Semiautomatic estimation

  11. Natural history of severe atheromatous disease of the thoracic aorta: a transesophageal echocardiographic study.

    Science.gov (United States)

    Montgomery, D H; Ververis, J J; McGorisk, G; Frohwein, S; Martin, R P; Taylor, W R

    1996-01-01

    This study sought to prospectively observe the morphologic and clinical natural history of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography. Atherosclerosis of the thoracic aorta has been shown to be highly associated with risk for embolic events in transesophageal studies, but the natural history of the disease under clinical conditions has not been reported. During a 20-month period, 191 of 264 patients undergoing transesophageal echocardiography had adequate visualization of the aorta to allow atherosclerotic severity to be graded as follows: grade I = normal (44 patients); grade II = intimal thickening (52 patients); grade III = atheroma or = 5 mm (19 patients); grade V = mobile lesion (14 patients). All available patients with grades IV (8 patients) and V (10 patients) disease as well as a subgroup of 12 patients with grade III disease had follow-up transesophageal echocardiographic studies (mean [+/- SD] 11.7 +/- 0.9 months, range 6 to 22). Of 30 patients undergoing follow-up transesophageal echocardiographic studies, 20 (66%) had no change in atherosclerotic severity grade. Of the remaining 10 patients, atherosclerotic severity progressed one grade in 7 and decreased in 3 with resolved mobile lesions. Of 18 patients with grade IV or V disease of the aorta who underwent a follow-up study, 11 (61%) demonstrated formation of new mobile lesions. Of 10 patients with grade V disease on initial study who underwent follow-up study, 7 (70%) demonstrated resolution of a specific previously documented mobile lesion. However, seven patients (70%) with grade V disease also demonstrated development of a new mobile lesion. Of 33 patients with grade IV or V disease, 8 (24%) died during the study period, and 1 (3%) had a clinical embolic event. The presence of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography is associated with a high mortality rate. Although the morphologic

  12. Analysis of the thoracic aorta using a semi-automated post processing tool

    International Nuclear Information System (INIS)

    Entezari, Pegah; Kino, Aya; Honarmand, Amir R.; Galizia, Mauricio S.; Yang, Yan; Collins, Jeremy; Yaghmai, Vahid; Carr, James C.

    2013-01-01

    Objective: To evaluates a semi-automated method for Thoracic Aortic Aneurysm (TAA) measurement using ECG-gated Dual Source CT Angiogram (DSCTA). Methods: This retrospective HIPAA compliant study was approved by our IRB. Transaxial maximum diameters of outer wall to outer wall were studied in fifty patients at seven anatomic locations of the thoracic aorta: annulus, sinus, sinotubular junction (STJ), mid ascending aorta (MAA) at the level of right pulmonary artery, proximal aortic arch (PROX) immediately proximal to innominate artery, distal aortic arch (DIST) immediately distal to left subclavian artery, and descending aorta (DESC) at the level of diaphragm. Measurements were performed using a manual method and semi-automated software. All readers repeated their measurements. Inter-method, intra-observer and inter-observer agreements were evaluated according to intraclass correlation coefficient (ICC) and Bland–Altman plot. The number of cases with manual contouring or center line adjustment for the semi-automated method and also the post-processing time for each method were recorded. Results: The mean difference between semi-automated and manual methods was less than 1.3 mm at all seven points. Strong inter-method, inter-observer and intra-observer agreement was recorded at all levels (ICC ≥ 0.9). The maximum rate of manual adjustment of center line and contour was at the level of annulus. The average time for manual post-processing of the aorta was 19 ± 0.3 min, while it took 8.26 ± 2.1 min to do the measurements with the semi-automated tool (Vitrea version 6.0.0.1 software). The center line was edited manually at all levels, with most corrections at the level of annulus (60%), while the contour was adjusted at all levels with highest and lowest number of corrections at the levels of annulus and DESC (75% and 0.07% of the cases), respectively. Conclusion: Compared to the commonly used manual method, semi-automated measurement of vessel dimensions is

  13. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  14. CMB lensing and giant rings

    Energy Technology Data Exchange (ETDEWEB)

    Rathaus, Ben; Itzhaki, Nissan, E-mail: nitzhaki@post.tau.ac.il, E-mail: ben.rathaus@gmail.com [Raymond and Beverly Sackler Faculty of Exact Sciences, School of Physics and Astronomy, Tel-Aviv University, Ramat-Aviv, 69978 (Israel)

    2012-05-01

    We study the CMB lensing signature of a pre-inationary particle (PIP), assuming it is responsible for the giant rings anomaly that was found recently in the WMAP data. Simulating Planck-like data we find that generically the CMB lensing signal to noise ratio associated with such a PIP is quite small and it would be difficult to cross correlate the temperature giant rings with the CMB lensing signal. However, if the pre-inationary particle is also responsible for the bulk flow measured from the local large scale structure, which happens to point roughly at the same direction as the giant rings, then the CMB lensing signal to noise ratio is fairly significant.

  15. Proton storage ring summer workshop

    International Nuclear Information System (INIS)

    Lawrence, G.P.; Cooper, R.K.

    1977-10-01

    During the week of August 16, 1976 a Workshop was held at the Los Alamos Scientific Laboratory (LASL) on the Proton Storage Ring (PSR) for the Weapons Neutron Research Facility (WNRF). Written contributions were solicited from each of the participants in the Workshop, and the contributions that were received are presented. The papers do not represent polished or necessarily complete work, but rather represent ''first cuts'' at their respective areas. Topics covered include: (1) background information on the storage ring; (2) WNRF design; (3) rf transient during filling; (4) rf capture; (5) beam bunch compression; (6) transverse space charge limits; (7) transverse resistive instability in the PSR; (8) longitudinal resistive instability; (9) synchrotron frequency splitting; (10) E Quintus Unum--off resonance; (11) first harmonic bunching in the storage ring; (12) kicker considerations; (13) beam extraction; (14) ferrite kicker magnets; and (15) E Quintus Unum: a possible ejection scheme

  16. New Main Ring control system

    International Nuclear Information System (INIS)

    Seino, K.; Anderson, L.; Ducar, R.; Franck, A.; Gomilar, J.; Hendricks, B.; Smedinghoff, J.

    1990-03-01

    The Fermilab Main Ring control system has been operational for over sixteen years. Aging and obsolescence of the equipment make the maintenance difficult. Since the advent of the Tevatron, considerable upgrades have been made to the controls of all the Fermilab accelerators except the Main Ring. Modernization of the equipment and standardization of the hardware and software have thus become inevitable. The Tevatron CAMAC serial system has been chosen as a basic foundation in order to make the Main Ring control system compatible with the rest of the accelerator complex. New hardware pieces including intelligent CAMAC modules have been designed to satisfy unique requirements. Fiber optic cable and repeaters have been installed in order to accommodate new channel requirements onto the already saturated communication medium system. 8 refs., 2 figs

  17. Tratamento cirúrgico dos aneurismas toracoabdominais da aorta Surgical treatment of thoracoabdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Januário M Souza

    1991-04-01

    Full Text Available Foram operados, em nosso Serviço, 161 aneurismas da aorta, sendo 99 por dissecção e 62 por outras causas. Em cinco pacientes, os aneurismas eram de localização toracoabdominal, sendo três por degeneração aterosclerótica e dois por dissecção; três pacientes eram do sexo feminino e a idade variou de 31 a 71 anos. Dois pacientes submeteram-se a aneurismectomia previamente (um da aorta ascendente e outro da porção proximal da aorta torácica. Revascularização miocárdica foi feita em um paciente, 40 dias antes da aneurismectomia. A indicação em todos os pacientes foi dor, causada por compressão do aneurisma, sendo que, em dois, havia insuficiência respiratória associada. Todos os pacientes foram operados através de incisão toracoabdominal e abertura do diafragma. A aorta foi substituída por tubo de Dacron, desde sua porção proximal até sua bifurcação, e as artérias viscerais foram implantadas no tubo. Quatro pacientes foram operados com pinçamento da aorta; um paciente necessitou emprego de circulação extracorpórea e parada circulatória, por impossibilidade de pinçamento da aorta junto à artéria subclávia. Todos os pacientes sobreviveram ao ato cirúrgico, ocorrendo dois óbitos no pós-operatório, um subitamente no 12º dia e outro por coma neurológico secundário a parada cardíaca causada por hipoxia.Five patients have been operated on of thoracoabdominal aortic aneurysms. The mean age was 53 years (range 31-71 and three were women. All the patients were symptomatic, three of them had arteriosclerotic aneurysms, and the other two had dissecting aneurysms. Three patients had been operated on previously. The exposure of aneurysm was made through a thoracoabdominal incision, in four patients clamps were placed above and below the aneurysm and it was incised longitudinally. Bypass between left atrium and left femoral artery with hypothermia and circulatory arrest was used in the other patients, since the

  18. Structure and catalytic activation of the TRIM23 RING E3 ubiquitin ligase: DAWIDZIAK et al.

    Energy Technology Data Exchange (ETDEWEB)

    Dawidziak, Daria M. [Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville Virginia; Sanchez, Jacint G. [Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville Virginia; Wagner, Jonathan M. [Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville Virginia; Ganser-Pornillos, Barbie K. [Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville Virginia; Pornillos, Owen [Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville Virginia

    2017-07-24

    Tripartite motif (TRIM) proteins comprise a large family of RING-type ubiquitin E3 ligases that regulate important biological processes. An emerging general model is that TRIMs form elongated antiparallel coiled-coil dimers that prevent interaction of the two attendant RING domains. The RING domains themselves bind E2 conjugating enzymes as dimers, implying that an active TRIM ligase requires higher-order oligomerization of the basal coiled-coil dimers. Here, we report crystal structures of the TRIM23 RING domain in isolation and in complex with an E2–ubiquitin conjugate. Our results indicate that TRIM23 enzymatic activity requires RING dimerization, consistent with the general model of TRIM activation.

  19. Tree rings and radiocarbon calibration

    International Nuclear Information System (INIS)

    Barbetti, M.

    1999-01-01

    Only a few kinds of trees in Australia and Southeast Asia are known to have growth rings that are both distinct and annual. Those that do are therefore extremely important to climatic and isotope studies. In western Tasmania, extensive work with Huon pine (Lagarostrobos franklinii) has shown that many living trees are more than 1,000 years old, and that their ring widths are sensitive to temperature, rainfall and cloud cover (Buckley et al. 1997). At the Stanley River there is a forest of living (and recently felled) trees which we have sampled and measured. There are also thousands of subfossil Huon pine logs, buried at depths less than 5 metres in an area of floodplain extending over a distance of more than a kilometre with a width of tens of metres. Some of these logs have been buried for 50,000 years or more, but most of them belong to the period between 15,000 years and the present. In previous expeditions in the 1980s and 1990s, we excavated and sampled about 350 logs (Barbetti et al. 1995; Nanson et al. 1995). By measuring the ring-width patterns, and matching them between logs and living trees, we have constructed a tree-ring dated chronology from 571 BC to AD 1992. We have also built a 4254-ring floating chronology (placed by radiocarbon at ca. 3580 to 7830 years ago), and an earlier 1268-ring chronology (ca. 7,580 to 8,850 years ago). There are many individuals, or pairs of logs which match and together span several centuries, at 9,000 years ago and beyond

  20. Adiabatic compression of ion rings

    International Nuclear Information System (INIS)

    Larrabee, D.A.; Lovelace, R.V.

    1982-01-01

    A study has been made of the compression of collisionless ion rings in an increasing external magnetic field, B/sub e/ = zB/sub e/(t), by numerically implementing a previously developed kinetic theory of ring compression. The theory is general in that there is no limitation on the ring geometry or the compression ratio, lambdaequivalentB/sub e/ (final)/B/sub e/ (initial)> or =1. However, the motion of a single particle in an equilibrium is assumed to be completely characterized by its energy H and canonical angular momentum P/sub theta/ with the absence of a third constant of the motion. The present computational work assumes that plasma currents are negligible, as is appropriate for a low-temperature collisional plasma. For a variety of initial ring geometries and initial distribution functions (having a single value of P/sub theta/), it is found that the parameters for ''fat'', small aspect ratio rings follow general scaling laws over a large range of compression ratios, 1 3 : The ring radius varies as lambda/sup -1/2/; the average single particle energy as lambda/sup 0.72/; the root mean square energy spread as lambda/sup 1.1/; and the total current as lambda/sup 0.79/. The field reversal parameter is found to saturate at values typically between 2 and 3. For large compression ratios the current density is found to ''hollow out''. This hollowing tends to improve the interchange stability of an embedded low β plasma. The implications of these scaling laws for fusion reactor systems are discussed

  1. Superconducting proton ring for PETRA

    International Nuclear Information System (INIS)

    Baynham, E.

    1979-01-01

    A powerful new facility for colliding beam physics could be provided by adding a proton storage ring in the range of several hundred GeV to the electron-positron storage ring PETRA at DESY. This can be achieved in an economic way utilizing the PETRA tunnel and taking advantage of the higher magnetic fields of superconducting magnets which would be placed above or below the PETRA magnets. A central field of 4 Tesla in the bending magnets corresponds to a proton energy of 225 GeV. (orig.)

  2. The Cryogenic Storage Ring CSR

    OpenAIRE

    von Hahn, Robert; Becker, Arno; Berg, Felix; Blaum, Klaus; Breitenfeldt, Christian; Fadil, Hisham; Fellenberger, Florian; Froese, Michael; George, Sebastian; Göck, Jürgen; Grieser, Manfred; Grussie, Florian; Guerin, Elisabeth A.; Heber, Oded; Herwig, Philipp

    2016-01-01

    An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed, and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ± 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion a...

  3. Supersymmetric rings in field theory

    International Nuclear Information System (INIS)

    Blanco-Pillado, Jose J.; Redi, Michele

    2006-01-01

    We study the dynamics of BPS string-like objects obtained by lifting monopole and dyon solutions of N = 2 Super-Yang-Mills theory to five dimensions. We present exact traveling wave solutions which preserve half of the supersymmetries. Upon compactification this leads to macroscopic BPS rings in four dimensions in field theory. Due to the fact that the strings effectively move in six dimensions the same procedure can also be used to obtain rings in five dimensions by using the hidden dimension

  4. Damping ring designs and issues

    International Nuclear Information System (INIS)

    Wolski, Andrzej; Decking, Winfried

    2003-01-01

    The luminosity performance of a future linear collider (LC) will depend critically on the performance of the damping rings. The design luminosities of the current LC proposals require rings with very short damping times, large acceptance, low equilibrium emittance and high beam intensity. We discuss the design strategies for lattices achieving the goals of dynamical stability, examine the challenges for alignment and coupling correction, and consider a variety of collective effects that threaten to limit beam quality. We put the design goals in context by referring to the experience of operating facilities, and outline the further research and development that is needed

  5. Laparoscopic appendicectomy using endo-ring applicator and fallope rings

    International Nuclear Information System (INIS)

    Ali, Iyoob V; Maliekkal, Joji I

    2009-01-01

    Wider adoption of laparoscopic appendicectomy (LA) is limited by problems in securing the appendiceal base as well as the cost and the duration compared with the open procedure. The objective of this study was to assess the feasibility and efficacy of a new method for securing the appendiceal base in LA, so as to make the entire procedure simpler and cheaper, and hence, more popular. Twenty-five patients who were candidates for appendicectomy (emergency as well as elective) and willing for the laparoscopic procedure were selected for this study. Ports used were 10 mm at the umbilicus, 5 mm at the lower right iliac fossa, and 10 mm at the left iliac fossa. Extremely friable, ruptured, or turgid organs of diameters larger than 8 mm were excluded from the study. The mesoappendix was divided close to the appendix by diathermy. Fallope rings were applied to the appendiceal base using a special ring applicator, and the appendix was divided and extracted through the lumen of the applicator. The procedure was successful in 23 (92%) cases, and the mean duration of the procedure was 20 minutes (15-32 minutes). There were no procedural complications seen during a median follow-up of two weeks. The equipment and rings were cheaper when compared with that of the standard methods of securing the base of the appendix. LA using fallope rings is a safe, simple, easy-to-learn, and economically viable method. (author)

  6. In vitro vascular effects produced by crude aqueous extract of green marine algae, Cladophora patentiramea (Mont.) Kützing, in aorta from normotensive rats.

    Science.gov (United States)

    Lim, Yee-Ling; Mok, Shiueh-Lian

    2010-01-01

    To investigate the antihypertensive activity of aqueous extracts obtained from Malaysian coastal seaweeds and to determine the pharmacological mechanisms of the extracts on rat aorta in vitro. The antihypertensive activity of 11 species of seaweeds (5 brown, 1 red and 5 green algae) were tested by cumulative addition of the extracts to phenylephrine (PE)-precontracted Wistar-Kyoto (WKY) aortic rings in in vitro isometric contraction studies. Mechanisms for vasorelaxant effect were investigated in the presence of various antagonists. Of the 11 species tested, 2 showed a vasorelaxant effect. Further investigation of the mechanisms of action of the aqueous extract of green alga, Cladophora patentiramea (AECP),showed that the vascular relaxant effect was endothelium- and concentration-dependent. A maximum relaxation of 45.8 +/- 4.6% (n = 8, p < 0.001) was obtained at 0.1 mg/ml of extract, after which the response was found to reduce in a concentration-dependent manner to 15.7 +/- 4.9% (n = 8, p < 0.001) at the highest extract concentration tested. Pretreatment of endothelium-intact aortic rings with Nomega-nitro-L-arginine methyl ester (L-NAME, 30 microM), (1)H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one (ODQ, 10 microM) and methylene blue (100 microM) resulted in a complete blockade of AECP-induced vasorelaxation. However, the relaxant effects of the extract were not blocked by atropine (1 microM), indomethacin (10 microM) and glibenclamide (10 microM), although the maximum relaxant responses were enhanced in the presence of glibenclamide. Our data showed that the in vitro vascular relaxant effect of AECPwas mediated through endothelium-dependent nitric oxide-cGMP pathway, and was not associated with the release of vasodilator prostaglandins, activation of muscarinic receptors, or ATP-sensitive potassium channels opening. Copyright 2010 S. Karger AG, Basel.

  7. Aortoscopia no tratamento das dissecções agudas da aorta Aortoscopy in the treatment of acute dissecting aneurysms of the aorta

    Directory of Open Access Journals (Sweden)

    Gladyston SOUTO

    1999-07-01

    Full Text Available No período de janeiro a dezembro de 1998 , foram operados 10 pacientes portadores de dissecção aguda da aorta (DA Ao 4 do tipo A e 6 do tipo B. O sexo masculino predominou e a idade dos pacientes variou de 34 a 78 anos. Em todos foram realizadas aortoscopias usando hipotermia profunda com parada circulatória total. Usou-se um gastroscópio, obtendo visão do lume da Ao, sendo que todos os pacientes tinham menos que 15 dias da doença. No tipo A, havia re-entrada abaixo da subclávia esquerda em 2 pacientes e, nos outros 2, na bifurcação das ilíacas. No tipo B, havia re-entrada ao nível das renais em 2 pacientes e, ao nível da bifurcação da Ao e das ilíacas, em 4. Em 2 pacientes do tipo A, a aortoscopia orientou na colocação de uma "Tromba de Elefante" como complemento. Nos outros 2, orientou na inversão do sentido da linha arterial. No tipo B, orientou na perfeita colocação da "Tromba de Elefante" e, em 4 pacientes, utilizamos a aortoscopia como complemento diagnóstico. O tempo utilizado na aortoscopia não alterou a morbimortalidade. Podemos concluir que a aortoscopia é um método de diagnóstico rápido, com boa definição das alterações anatômicas da Ao, permitindo um tratamento efetivo. Nos casos agudos instáveis podemos dispensar alguns exames pré-operatórios para não retardarmos a operação. O diagnóstico da re-entrada nos seguimentos inferiores da Ao ajuda a evitar a dissecção retrógrada. Acreditamos que a aortoscopia poderá, no futuro, ser de grande ajuda no diagnóstico e tratamento das DA Ao, bem como de outras lesões da Ao.From January to December 1998, ten patients with dissecting aneurysms of the Aorta (ADA Ao were operated on, 4 type A and 6 type B. Males predominated and ages ranged from 34 to 78 years. In all of them aortoscopy was performed with deep hypothermia and circulatory arrest. A gastroscope was used with visualization of the aortic lumen and all patients had less than 15 days of disease

  8. Tratamento cirúrgico da coarctação de aorta pela aortoplastia trapezoidal Surgical treatment of coarctation of the aorta using trapezoidal aortoplasty

    Directory of Open Access Journals (Sweden)

    Jarbas Jakson Dinkhuysen

    2004-01-01

    Full Text Available OBJETIVO: A aortoplastia trapezoidal é uma variante técnica da anastomose término-terminal que, amparada em elementos da geometria, objetiva aumentar o diâmetro da aorta ao nível da sutura reduzida e, consequentemente, a manutenção de gradientes pressóricos residuais ou recorrentes indesejáveis a curto e a longo prazo. MÉTODOS: Após a ressecção da área coarctada e tecido ductal, são confeccionados em cada coto aórtico 3 trapezóides que, ao serem confrontados, criam linha de sutura com aspecto sinusoidal (zigue-zague. Foram operados por esta técnica 33 pacientes, a maioria homens, com idades variando de 3 meses a 36 anos (m 9,5 ± 9,7. RESULTADOS: Não ocorreu mortalidade imediata ou tardia e o tempo de evolução a longo prazo foi de 1,1 a 7,6 anos (m 3,6 ± 3,4. A maioria dos pacientes ficou assintomática com níveis normais de pressão arterial, possibilitando a descontinuação da terapêutica antihipertensiva (pOBJECTIVE: Trapezoidal aortoplasty is a technical variant of end-to-end anastomosis, which, based on elements of geometry, aims at increasing the diameter of the aorta at the level of the suture, therefore reducing the occurrence of residual or recurrent pressure gradients in the short and long run. METHODS: After resecting the coarcted area and ductal tissue, 3 trapezoids are confected in each aortic stump, which, when confronted, create a suture line with a sinusoidal aspect (zigzag. Thirty-three patients underwent surgery with this technique, 22 (66.7% males, with ages ranging from 3 months to 36 years (mean of 9.84 ± 9.69. RESULTS: No immediate or late deaths occurred. Follow-up ranged from 1.1 to 7.6 years (mean of 3.6 ± 3.4. Most patients became asymptomatic with normal blood pressure levels, enabling the discontinuation of antihypertensive therapy (P<0.0001. A significant reduction in the pressure gradients was observed on Doppler echocardiography and during cardiac catheterization (P<0.001. The analysis of

  9. Isolated galaxies

    International Nuclear Information System (INIS)

    Einasto, Maret

    1990-01-01

    To test for the possible presence of really isolated galaxies, which form a randomly distributed population in voids, we compare the distribution of most isolated galaxies in an observed sample with distributions of the same number of random points using the nearest neighbour test. The results show that the random population of really isolated galaxies does not exist - even the most isolated galaxies are connected with systems of galaxies, forming their outlying parts. (author)

  10. "Stent" auto-expansível nas dissecções da aorta tipo B Self-expanding stent in type B dissections of the aorta

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    1999-07-01

    Full Text Available O tratamento clínico das dissecções agudas da aorta do tipo B tem mortalidade em torno de 25% menor que a mortalidade cirúrgica. O tratamento cirúrgico das dissecções crônicas também produz uma morbidade e mortalidade elevadas. A utilização de "stents"auto-expansíveis endovasculares pode ser uma nova alternativa no tratamento destas lesões. De abril a dezembro de 1998 foram implantados 15 "stents" endovasculares, 10 em dissecções agudas e 5 em crônicas. A idade dos pacientes variou entre 48 e 75 anos (média=60,53±9,73 anos com 66,6% do sexo masculino. Os pacientes foram submetidos à esternotomia mediana, circulação extracorpórea (CEC com hipotermia profunda (18° - 20°C, parada circulatória total (PCT e perfusão cerebral retrógrada (PCR. A aorta transversa foi incisada e implantado o "stent" na aorta descendente sob auxílio de aortoscopia. Foram analisados os tempos de CEC, pinçamento aórtico, PCT, PCR, reaquecimento, ventilação mecânica, internação, sangramento trans e pós-operatório, reposição sangüínea, gasometria, curva de eventos e sobrevida. A mortalidade hospitalar (30 dias foi de 6,6%; 2 pacientes foram reoperados com 3 e 6 meses após a operação com dissecção da aorta ascendente e aneurisma roto distal ao "stent". Quatorze vêm sendo acompanhados com 1 a 8m de evolução, sendo que 85,7% estão livres de eventos e curva de sobrevida de 93,1%(240 dias. Concluímos que o implante de "stent"intraluminais auto-expansíveis apresentou mortalidade menor na fase aguda da doença (6,6% comparada à nossa experiência anterior com o tratamento clínico (30%. Apesar da amostra ser pequena, o procedimento parece ser promissor e necessita mais acompanhamento.The clinical treatment of acute type B aortic dissection has a mortality of about 25%, therefore, less than surgical mortality. The surgical treatment of chronic dissections also produces a high morbidity and mortality. The use of self

  11. Acute ethanol intake induces superoxide anion generation and mitogen-activated protein kinase phosphorylation in rat aorta: A role for angiotensin type 1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Yogi, Alvaro; Callera, Glaucia E. [Kidney Research Centre, Ottawa Hospital Research Institute, University of Ottawa, Ontario (Canada); Mecawi, André S. [Department of Physiology, Faculty of Medicine of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP (Brazil); Batalhão, Marcelo E.; Carnio, Evelin C. [Department of General and Specialized Nursing, College of Nursing of Ribeirão Preto, USP, São Paulo (Brazil); Antunes-Rodrigues, José [Department of Physiology, Faculty of Medicine of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP (Brazil); Queiroz, Regina H. [Department of Clinical, Toxicological and Food Science Analysis, Faculty of Pharmaceutical Sciences, USP, São Paulo (Brazil); Touyz, Rhian M. [Kidney Research Centre, Ottawa Hospital Research Institute, University of Ottawa, Ontario (Canada); Tirapelli, Carlos R., E-mail: crtirapelli@eerp.usp.br [Department of Psychiatric Nursing and Human Sciences, Laboratory of Pharmacology, College of Nursing of Ribeirão Preto, USP, Ribeirão Preto, SP (Brazil)

    2012-11-01

    Ethanol intake is associated with increase in blood pressure, through unknown mechanisms. We hypothesized that acute ethanol intake enhances vascular oxidative stress and induces vascular dysfunction through renin–angiotensin system (RAS) activation. Ethanol (1 g/kg; p.o. gavage) effects were assessed within 30 min in male Wistar rats. The transient decrease in blood pressure induced by ethanol was not affected by the previous administration of losartan (10 mg/kg; p.o. gavage), a selective AT{sub 1} receptor antagonist. Acute ethanol intake increased plasma renin activity (PRA), angiotensin converting enzyme (ACE) activity, plasma angiotensin I (ANG I) and angiotensin II (ANG II) levels. Ethanol induced systemic and vascular oxidative stress, evidenced by increased plasma thiobarbituric acid-reacting substances (TBARS) levels, NAD(P)H oxidase‐mediated vascular generation of superoxide anion and p47phox translocation (cytosol to membrane). These effects were prevented by losartan. Isolated aortas from ethanol-treated rats displayed increased p38MAPK and SAPK/JNK phosphorylation. Losartan inhibited ethanol-induced increase in the phosphorylation of these kinases. Ethanol intake decreased acetylcholine-induced relaxation and increased phenylephrine-induced contraction in endothelium-intact aortas. Ethanol significantly decreased plasma and aortic nitrate levels. These changes in vascular reactivity and in the end product of endogenous nitric oxide metabolism were not affected by losartan. Our study provides novel evidence that acute ethanol intake stimulates RAS activity and induces vascular oxidative stress and redox-signaling activation through AT{sub 1}-dependent mechanisms. These findings highlight the importance of RAS in acute ethanol-induced oxidative damage. -- Highlights: ► Acute ethanol intake stimulates RAS activity and vascular oxidative stress. ► RAS plays a role in acute ethanol-induced oxidative damage via AT{sub 1} receptor activation.

  12. Tocotrienol rich tocomin attenuates oxidative stress and improves endothelium-dependent relaxation in aortae from rats fed a high-fat western diet

    Directory of Open Access Journals (Sweden)

    Saher F Ali

    2016-10-01

    Full Text Available We have previously reported that tocomin, a mixture high in tocotrienol content and also containing tocopherol, acutely preserves endothelial function in the presence of oxidative stress. In this study we investigated whether tocomin treatment would preserve endothelial function in aortae isolated from rats fed a high fat diet known to cause oxidative stress. Wistar hooded rats were fed a western diet (WD, 21% fat or control rat chow (SD, 6% fat for 12 weeks. Tocomin (40 mg/kg/day sc or its vehicle (peanut oil was administered for the last 4 weeks of the feeding regime. Aortae from WD rats showed an impairment of endothelium-dependent relaxation that was associated with an increased expression of the NADPH oxidase Nox2 subunit and an increase in the vascular generation of superoxide measured using L-012 chemiluminescence. The increase in vascular oxidative stress was accompanied by a decrease in basal NO release and impairment of the contribution of NO to ACh-induced relaxation. The impaired relaxation is likely contributed to by a decreased expression of eNOS, calmodulin and phosphorylated Akt and an increase in caveolin-Tocotrienol rich tocomin, which prevented the diet-induced changes in vascular function, reduced vascular superoxide production and abolished the diet-induced changes in eNOS and other protein expression. Using selective inhibitors of nitric oxide synthase (NOS, soluble guanylate cyclase (sGC and calcium activated potassium (KCa channels we demonstrated that tocomin increased NO mediated relaxation, without affecting the contribution of endothelium-dependent hyperpolarization type relaxation to the endothelium-dependent relaxation. The beneficial actions of tocomin in this diet-induced model of obesity suggests that it may have potential to be used as a therapeutic agent to prevent vascular disease in obesity.

  13. Examination techniques for non-magnetic rings

    International Nuclear Information System (INIS)

    Metala, M.J.; Kilpatrick, N.L.; Frank, W.W.

    1990-01-01

    Until the introduction of 18Mn18Cr rings a few years ago, most non-magnetic steel rings for generator rotors were made from 18Mn5Cr alloy steel, which is highly susceptible to stress corrosion cracking in the presence of water. This, the latest in a series of papers on the subject of non-magnetic rings by the authors' company, provides a discussion of nondestructive examination of 18Mn5Cr rings for stress corrosion distress. With rings on the rotor, fluorescent penetrant, ultrasonic and special visual techniques are applied. With rings off the rotor, the fluorescent penetrant technique is used, with and without stress enhancement

  14. Study of the effect of thiols on the vasodilatory potency of S-nitrosothiols by using a modified aortic ring assay

    International Nuclear Information System (INIS)

    Giustarini, Daniela; Tsikas, Dimitrios; Rossi, Ranieri

    2011-01-01

    Both low-molecular-mass thiols (LMM-SH) and protein thiols (P-SH) can modulate the biological activity of S-nitrosothiols (RSNO) via S-transnitrosation reactions. It has been difficult to evaluate the entity of this effect in blood circulation by in vitro assays with isolated aorta rings so far, because media rich in proteins cannot be used due to the foaming as a consequence of the needed gas bubbling. We have modified the original apparatus for organ bioassay in order to minimize foaming and to increase analytical performance. By using this modified bioassay we investigated the vasodilatory potency of various endogenous RSNOs in the presence of physiologically relevant concentrations of albumin and LMM-SH. Our results show that the sulfhydryl group of the cysteine moiety of albumin and LMM-SH has a dramatic effect on the vasodilatory potency of RSNO. Considering the equilibrium constants for S-transnitrosation reactions and the concentration of P-SH and LMM-SH we measured in healthy humans (aged 18-85 years), we infer that the age-dependency of hematic levels of LMM-SH may have a considerable impact in RSNO-mediated vasodilation. S-Nitrosoproteins such as S-nitrosoalbumin may constitute a relatively silent and constant amount of circulating RSNO. On the other hand, LMM-SH may mediate and control the biological actions of S-nitrosoproteins via S-transnitrosation reactions, by forming more potent nitric oxide-releasing LMM-S-nitrosothiols. Lifestyle habits, status of health and individual age are proven factors that, in turn, may influence the concentration of these compounds. These aspects should be taken into consideration when testing the vasodilatory effects of RSNO in pre-clinical studies. - Highlights: → A modification of the organ chamber apparatus for aortic ring bioassays is proposed. → The new apparatus can work in the presence of albumin at physiological concentrations. → Potency of RSNOs was studied in the presence of albumin and low molecular

  15. Ring diagrams and phase transitions

    International Nuclear Information System (INIS)

    Takahashi, K.

    1986-01-01

    Ring diagrams at finite temperatures carry most infrared-singular parts among Feynman diagrams. Their effect to effective potentials are in general so significant that one must incorporate them as well as 1-loop diagrams. The author expresses these circumstances in some examples of supercooled phase transitions

  16. WR stars with ring nebulae

    International Nuclear Information System (INIS)

    Tutukov, A.

    1982-01-01

    It is shown that most of usually apparently single nitrogen WR stars with ring emission nebulae around them (WN + Neb) are a probable product of the evolution of a massive close binary with initial masses of components exceeding approximately 20 solar masses. (Auth.)

  17. Alignment for new Subaru ring

    International Nuclear Information System (INIS)

    Zhang, Ch.; Matsui, S.; Hashimoto, S.

    1999-01-01

    The New SUBARU is a synchrotron light source being constructed at the SPring-8 site. The main facility is a 1.5 GeV electron storage ring that provides light beam in the region from VUV to soft X-ray using SPring-8's 1 GeV linac as an injector. The ring, with a circumference of about 119 meters, is composed of six bending cells. Each bending cell has two normal dipoles of 34 degree and one inverse dipole of -8 degree. The ring has six straight sections: two very long straight sections for a 11-m long undulator and an optical klystron, four short straight sections for a 2.3-m undulator, a super-conducting wiggler, rf cavity and injection, etc. The magnets of the storage ring are composed of 12 dipoles (BMs), 6 invert dipoles (BIs), 56 quadrupoles and 44 sextupoles, etc. For the magnet alignment, positions of the dipoles (the BMs and BIs) are determined by network survey method. The multipoles, which are mounted on girders between the dipoles, are aligned with a laser-CCD camera system. This article presents the methodology used to position the different components and particularly to assure the precise alignment of the multipoles. (authors)

  18. Characteristic of Rings. Prime Fields

    Directory of Open Access Journals (Sweden)

    Schwarzweller Christoph

    2015-12-01

    Full Text Available The notion of the characteristic of rings and its basic properties are formalized [14], [39], [20]. Classification of prime fields in terms of isomorphisms with appropriate fields (ℚ or ℤ/p are presented. To facilitate reasonings within the field of rational numbers, values of numerators and denominators of basic operations over rationals are computed.

  19. Ring laser frequency biasing mechanism

    International Nuclear Information System (INIS)

    McClure, R.E.

    1975-01-01

    A ring laser cavity including a magnetically saturable member for differentially phase shifting the contradirectional waves propagating in the laser cavity, the phase shift being produced by the magneto-optic interaction occurring between the light waves and the magnetization in the cavity forming component as the light waves are reflected therefrom is described

  20. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  1. Progressiv læring

    DEFF Research Database (Denmark)

    Wahlgren, Bjarne

    2017-01-01

    SAMMENFATNING I denne evalueringsrapport præsenterer Nationalt Center for Kompetenceudvikling ved Aarhus Universitet (herefter NCK) og Rambøll Management Consulting (herefter Rambøll) den værktøjsspecifikke evaluering af Progressiv Læring som pædagogisk værktøj for de ni implementeringsskoler i s...

  2. Wands of the Black Ring

    Czech Academy of Sciences Publication Activity Database

    Pravda, Vojtěch; Pravdová, Alena

    2005-01-01

    Roč. 37, č. 7 (2005), s. 1277-1287 ISSN 0001-7701 R&D Projects: GA ČR GP202/03/P017; GA AV ČR KJB1019403 Institutional research plan: CEZ:AV0Z10190503 Keywords : algebraic classification * Petrov classification * black ring Subject RIV: BA - General Mathematics Impact factor: 1.550, year: 2005

  3. Substitution of matrices over rings

    NARCIS (Netherlands)

    Hautus, M.L.J.

    1995-01-01

    For a given commutative ring with an identity element, we define and study the substitution of a matrix with entries in into a matrix polynomial or rational function over . A Bezout-type remainder theorem and a "partial-substitution rule" are derived and used to obtain a number of results. The

  4. Exercises in modules and rings

    CERN Document Server

    Lam, TY

    2009-01-01

    This volume offers a compendium of exercises of varying degree of difficulty in the theory of modules and rings. All exercises are solved in full detail. Each section begins with an introduction giving the general background and the theoretical basis for the problems that follow.

  5. On commutativity theorems for rings

    Directory of Open Access Journals (Sweden)

    H. A. S. Abujabal

    1990-01-01

    Full Text Available Let R be an associative ring with unity. It is proved that if R satisfies the polynomial identity [xny−ymxn,x]=0(m>1,n≥1, then R is commutative. Two or more related results are also obtained.

  6. Screening for abdominal aortic aneurysms Rastreamento de aneurismas da aorta abdominal

    Directory of Open Access Journals (Sweden)

    Telmo Pedro Bonamigo

    2003-01-01

    Full Text Available OBJECTIVE AND METHODS: Screening for abdominal aortic aneurysms may be useful to decrease mortality related to rupture. We conducted a study to assess the prevalence of abdominal aortic aneurysms in southern Brazil and to define risk factors associated with high prevalence of this disorder. The screening was conducted using abdominal ultrasound. Three groups were studied: Group 1 - cardiology clinic patients; Group 2 - individuals with severe ischemic disease and previous coronary surgery, or important lesions on cardiac catheterism; Group 3 - individuals without cardiac disease selected from the general population. All individuals were male and older than 54 years of age. The ultrasonographic diagnosis of aneurysm was based on an anteroposterior abdominal aorta diameter of 3 cm, or on an abdominal aorta diameter 0.5 cm greater than that of the supra-renal aorta. RESULTS: A total of 2.281 people were screened for abdominal aortic aneurysms in all groups: Group 1 - 768 individuals, Group 2 - 501 individuals, and Group 3 - 1012 individuals. The prevalence of aneurysms was 4.3%, 6.8% and 1.7%, respectively. Age and cigarette smoking were significantly associated with increased prevalence of aneurysms, as was the diagnosis of peripheral artery disease. DISCUSSION: We concluded that screening may be an important tool to prevent the mortality associated with abdominal aortic aneurysms surgery. Additionally, the cost of screening can be decreased if only individuals presenting significant risk factors, such as coronary and peripheral artery disease, smokers and relatives of aneurysm patients, are examined.OBJETIVO E MÉTODOS: O rastreamento de aneurisma da aorta abdominal infra-renal é importante pois pode diminuir a mortalidade relacionada à ruptura. Realizamos um estudo para definir a prevalência desses aneurismas em diversos segmentos da população em nossa região do Brasil. O rastreamento foi realizado utilizando-se a ecografia de abdômen. Tr

  7. Matrix metalloproteinases. Their role in degenerative chronic diseases of abdominal aorta.

    Science.gov (United States)

    Palombo, D; Maione, M; Cifiello, B I; Udini, M; Maggio, D; Lupo, M

    1999-04-01

    The main chronic degenerative diseases of the abdominal aorta, namely aneurysmatic and steno-obstructive pathologies, have a common denominator: atherosclerosis. Both pathologies are characterised by the destruction of the structural integrity of the extracellular protein matrix (ME). A number of studies have shown the presence and involvement of a group of enzymes with proteolytic activity towards one or more ME components, the matrix metalloproteinases (MMPs), in the pathogenesis of aneurysms of the abdominal aorta. Other authors have underlined the role of MMPs in the proliferation and migration process of smooth muscle cells into the intima in the pathogenesis of atheromasic plaque. The aim of this study was to evaluate the possible role of these enzymes in the pathogenesis of chronic degenerative diseases of the aorta. Fragments of aortic wall were removed from patients undergoing elective aortic surgery for aneurysms (14 patients) or aortic steno-obstruction (4 patients). The samples obtained were treated appropriately and then subject to immunohistochemical analysis. The preparations were incubated with specific anti-MMP antibodies and were also incubated with substrate and chromogen, forming a pigmented precipitate on the site of the antigen, before being observed using an optic microscopic at an enlargement of 250x. Nuclear positivity linked to the presence of the antigen testified the validity of staining. Lastly, the MMP INDEX, or in other words the number of positive cells out of 100, was stained in the adventitia and in the tunica media in each preparation. MMPs were divided into three main groups: interstitial collagenase (MMP1) which degrade type I and III native collagen; gelatinases (MMP9, MMP2) which act on elastin and type IV collagen; stromelysins (MMP3) with specific proteolytic action towards proteoglycans, fibronectin and laminine. In our experience, those preparations obtained from aorta affected by steno-obstructive pathologies (4 patients

  8. Estimation of prenatal aorta intima-media thickness in ultrasound examination

    Science.gov (United States)

    Veronese, Elisa; Poletti, Enea; Cosmi, Erich; Grisan, Enrico

    2012-03-01

    Prenatal events such as intrauterine growth restriction have been shown to be associated with an increased thickness of abdominal aorta in the fetus. Therefore the measurement of abdominal aortic intima-media thickness (aIMT) has been recently considered a sensitive marker of artherosclerosis risk. To date measure of aortic diameter and of aIMT has been performed manually on US fetal images, thus being susceptible to intra- and inter- operator variability. This work introduces an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from videos recorded during routine third trimester ultrasonographic fetal biometry. Firstly, in each frame, the algorithm locates and segments the region corresponding to aorta by means of an active contour driven by two different external forces: a static vector field convolution force and a dynamic pressure force. Then, in each frame, the mean diameter of the vessel is computed, to reconstruct the cardiac cycle: in fact, we expect the diameter to have a sinusoidal trend, according to the heart rate. From the obtained sinusoid, we identify the frames corresponding to the end diastole and to the end systole. Finally, in these frames we assess the aIMT. According to its definition, we consider as aIMT the distance between the leading edge of the blood-intima interface, and the leading edge of the media-adventitia interface on the far wall of the vessel. The correlation between end-diastole and end-systole aIMT automatic and manual measures is 0.90 and 0.84 respectively.

  9. Dynamic Geometric Analysis of the Renal Arteries and Aorta following Complex Endovascular Aneurysm Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Kim, John J; Lee, Jason T; Dalman, Ronald L; Cheng, Christopher P

    2017-08-01

    Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P renals exhibited increased end-stent angulation (12 ± 15°, P renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The effects of Euphorbia hirta on the ultrastructure of the murine liver, kidney and aorta

    Science.gov (United States)

    WONG, J.Y.R.; CHEN, Y.S.; CHAKRAVARTHI, S.; JUDSON, J.P.; L., SANTHANA RAJ; ER, H.M.

    2013-01-01

    Euphorbia hirta is widely used in traditional remedies and has been used cross-culturally for generations against maladies such as asthma, skin ailments and hypertension. Previous studies have demonstrated that Euphorbia hirta has antibacterial activity, and have also indicated certain antimolluscidal, antimalarial and anti-inflammatory properties, the latter of which have been suggested to be more pronounced than those of the rheumatological drug, etanercept. To date, no studies have identified the anatomical effects of this herb on the organs of test animals. This study aimed to identify the effects of Euphorbia hirta on the ultrastructure of the murine liver, kidney and aorta. A total of 32 adult male Sprague-Dawley rats were divided into four groups; three groups were fed with aqueous extracts of Euphorbia hirta at doses of 1, 10 and 50 mg/kg, respectively, every alternate day for 50 days, while one group served as a control. The animals were later sacrificed and the liver, kidney and aorta harvested for examination by electron microscopy. The aorta showed no ultrastructural changes across the groups. Renal and hepatic tissue from the treated groups demonstrated dose-dependent injuries, which showed architectural damage beginning in the nuclei and spreading outwards. Taking into consideration the properties of Euphorbia hirta that have been described in previous studies, in addition to the results from the present study, it appears that the herb may exhibit similar effects to those of the quinolone group of antibiotics. Further in-depth investigations are required into the potential effects of Euphorbia hirta, deleterious and otherwise. PMID:24223653

  11. A rare cause of acute abdomen at a young patient: aorta and superior mesenteric artery dissection

    International Nuclear Information System (INIS)

    Kara, K.; Bozlar, U.; Guler, A.; Tasar, M.

    2012-01-01

    Full text: Introduction: Aortic emergencies are some of the most important causes of sudden death. Acute mesenteric ischemia has a low incidence about one in 1000 patients acutely admitted to a hospital but a high mortality rate of about 70%. In aortic dissection, only 3-5% of cases are found to be complicated by a superior mesentery artery (SMA) occlusion Objectives and tasks: The aim of the presentation is to demonstrate the computed tomography (CT) angiography findings of the dissection at aorta and SMA which is a rare cause of acute abdomen at a young patient. Materials and methods: A 22-year-old patient was admitted to emergency department suffering from severe abdominal pain, nausea and vomiting. Physical examination revealed abdominal tenderness. CT angiography was performed for the possible diagnosis like acute appendicitis and mesenteric ischemia. Formation of the intimal flap at the abdominal aorta and high grade narrowed celiac trunk at the origin that is in the true lumen were seen. Formation of the intimal flap at the aorta was extending through the SMA and SMA was filling both from true and false lumen. The same flap formation was narrowing the lumen of proximal SMA extensively. It was continued to the central part of SMA and a thrombus was detected at that level in the false lumen. Conclusion: Although patients at the younger age group, dissection should be considered in the differential diagnosis of acute abdominal pain. CT angiography is a rapid, noninvasive and effective method to detect vascular pathology, to asses the prevalence and to help treatment planning

  12. Re-interventions on the thoracic and thoracoabdominal aorta in patients with Marfan syndrome.

    Science.gov (United States)

    Schoenhoff, Florian S; Carrel, Thierry P

    2017-11-01

    The advent of multi-gene panel genetic testing and the discovery of new syndromic and non-syndromic forms of connective tissue disorders have established thoracic aortic aneurysms as a genetically mediated disease. Surgical results in patients with Marfan syndrome (MFS) provide an important benchmark for this patient population. Prophylactic aortic root surgery prevents acute dissection and has contributed to the improved survival of MFS patients. In the majority of patients, re-interventions are driven by a history of dissection. Patients undergoing elective root repair have a low risk for re-interventions on the root itself. Experienced centers have results after valve-sparing procedures at 10 years comparable with those seen after a modified Bentall procedure. In patients where only the ascending aorta was replaced during the initial surgery, re-intervention rates are high as the root continues to dilate. The fate of the aortic arch in MFS patients presenting with dissection is strongly correlated with the extent of the initial surgery. Not replacing the entire ascending aorta and proximal aortic arch results in a high rate of re-interventions. Nevertheless, the additional burden of replacing the entire aortic arch during emergent proximal repair is not very well defined and makes comparisons with patients undergoing elective arch replacement difficult. Interestingly, replacing the entire aortic arch during initial surgery for acute dissection does not protect from re-interventions on downstream aortic segments. MFS patients suffering from type B dissection have a high risk for re-interventions ultimately leading up to replacement of the entire thoracoabdominal aorta even if the dissection was deemed uncomplicated by conventional criteria. While current guidelines do not recommend the implantation of stent grafts in MFS patients, implantation of a frozen-elephant-trunk to create a stable proximal landing zone for future endovascular or open procedures has

  13. Athletes and the Aorta: Normal Adaptations and the Diagnosis and Management of Pathology.

    Science.gov (United States)

    Stephen Hedley, J; Phelan, Dermot

    2017-10-09

    Over a hundred years ago, physicians first recognized that participation in regular, vigorous training resulted in enlargement of the heart. Since that time, the term "athlete's heart" has entered the medical lexicon as a global expression encompassing the electrical, functional, and morphological adaptations that develop in response to physical training. Exercise-induced adaptations of the aorta, which is also exposed to large hemodynamic stresses during prolonged endurance exercise or resistance training, are less well recognized. Young athletes tend to have slightly larger aortas than their sedentary counterparts; however, this rarely exceeds normal ranges for the general population. A systematic approach is advised when presented with an athlete with aortic enlargement. The size of the aorta needs to be first put in the context of the athlete's age, sex, size, and sporting endeavors; however, even in the largest young athletes, the aortic root rarely exceeds 4 cm in men or 3.4 cm in women. A comprehensive evaluation is advised which includes a detailed family history and a thorough physical examination evaluating for signs of any defined connective tissue disorder associated with aortopathy. Downstream testing is then tailored for the individual and may include further tomographic imaging, opthalmology review, and genetic testing. This should ideally be performed at a specialist center. Management of athletes with an aortopathy includes tailoring athletic activity, medical management with strict impulse control, and, in some cases, prophylactic surgery. The issue of sporting eligibility should be individualized and if disqualification is necessary, this should be undertaken by a sports cardiologist or an expert in aortic disease with experience in dealing with an athletic population.

  14. Dacron graft as replacement to dissected aorta: A three-dimensional fluid-structure-interaction analysis.

    Science.gov (United States)

    Jayendiran, R; Nour, B M; Ruimi, A

    2018-02-01

    Aortic dissection (AD) is a serious medical condition characterized by a tear in the intima, the inner layer of the aortic walls. In such occurrence, blood is being diverted to the media (middle) layer and may result in patient death if not quickly attended. In the case where the diseased portion of the aorta needs to be replaced, one common surgical technique is to use a graft made of Dacron, a synthetic fabric. We investigate the response of a composite human aortic segment-Dacron graft structure subjected to blood flow using the three-dimensional fluid-structure-interaction (FSI) capability in Abaqus. We obtain stress and strain profiles in each of the three layers of the aortic walls as well as in the Dacron graft. Results are compared when elastic and hyperelastic models are used and when isotropy vs. anisotropy is assumed. The more complex case (hyperelastic-anisotropy) is represented by the Holzapfel-Gasser-Ogden (HGO) model which also accounts for the orientation of the fibers present in the tissues. The fluid flow is taken as Newtonian, incompressible, pulsatile and turbulent. The simulation show that for all the cases, the von Mises stress distribution at aorta-Dacron interface is well below the ultimate strength of the aorta. No significant change in radial displacement at the interface of the two materials due to blood flow is observed. Computation cost is also addressed and results show that the hyperelastic-anisotropic model takes about three times longer to run than the elastic isotropic case. Trade-off between accuracy and computational cost has to be weighted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Transfer of Learning from Practicing Microvascular Anastomosis on Silastic Tubes to Rat Abdominal Aorta.

    Science.gov (United States)

    Mokhtari, Pooneh; Tayebi Meybodi, Ali; Lawton, Michael T; Payman, Andre; Benet, Arnau

    2017-12-01

    Learning to perform microvascular anastomosis is difficult. Laboratory practice models using artificial vessels are frequently used for this purpose. However, the efficacy of such practice models has not been objectively assessed for the performance of microvascular anastomosis during live surgical settings. This study was conducted to assess the transfer of learning from practicing microvascular anastomosis on tubes to anastomosing rat abdominal aorta. Ten surgeons without any experience in microvascular anastomosis were randomly assigned to an experimental or a control group. Both groups received didactic and visual training on end-to-end microvascular anastomosis. The experimental group received 24 sessions of hands-on training on microanastomosis using Silastic tubes. Next, both groups underwent recall tests on weeks 1, 2, and 8 after training. The recall test consisted of completing an end-to-end anastomosis on the rat's abdominal aorta. Anastomosis score, the time to complete the anastomosis, and the average time to place 1 stitch on the vessel perimeter were compared between the 2 groups. Compared with the control group, the experimental group did significantly better in terms of anastomosis score, total time, and per-stitch time. The measured variables showed stability and did not change significantly between the 3 recall tests. The skill of microvascular anastomosis is transferred from practicing on Silastic tubes to rat's abdominal aorta. Considering the relative advantages of Silastic tubes to live rodent surgeries, such as lower cost and absence of ethical issues, our results support the widespread use of Silastic tubes in training programs for microvascular anastomosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Increased interleukin-11 levels in thoracic aorta and plasma from patients with acute thoracic aortic dissection.

    Science.gov (United States)

    Xu, Yao; Ye, Jing; Wang, Menglong; Wang, Yuan; Ji, Qingwei; Huang, Ying; Zeng, Tao; Wang, Zhen; Ye, Di; Jiang, Huimin; Liu, Jianfang; Lin, Yingzhong; Wan, Jun

    2018-06-01

    Interleukin (IL) 11 is closely related to tumor and hematological system diseases. Recent studies have demonstrated that IL-11 also participates in cardiovascular diseases, including ischemia-reperfusion mediated heart injury and acute myocardial infarction. This study aimed to investigate whether IL-11 is involved in acute thoracic aortic dissection (TAD). Aortic tissue samples from normal donors and acute TAD patients were collected, and the expression of IL-11 in all aortic tissue was analyzed. In addition, blood samples from patients with chest pain were collected and divided into a non-AD (NAD) group and a TAD group according to the results of computed tomography angiography of the thoracic aorta. The plasma IL-11, IL-17 and interferon (IFN) γ in all blood samples were measured. Compared with aortic tissue of normal controls, IL-11 was significantly increased in aortic tissue of acute TAD patients, especially in the torn section. The IL-11 was derived from aorta macrophages in TAD. In addition, the plasma IL-11, IL-17 and IFN-γ were significantly higher in acute TAD patients than in NAD patients, and the correlation analysis showed that IL-11 levels were positively correlated with levels of IFN-γ, IL-17, glucose, systolic blood pressure, diastolic blood pressure, white blood cells, C-reactive proteins and D-dimers. Binary logistic regression analyses showed that elevated IL11 in patients who may have diagnostic value of TAD, but less that D-dimer. IL-11 was increased in thoracic aorta and plasma of TAD patients and may be a promising biomarker for diagnosis in patients with TAD. Copyright © 2018. Published by Elsevier B.V.

  17. Endovascular Management of Aorta-Iliac Stenosis and Occlusive Disease by Kissing-Stent Technique

    Directory of Open Access Journals (Sweden)

    Meng Liu

    2016-01-01

    Full Text Available Kissing-stenting treatment has been used to treat patients with peripheral artery disease (PAD. However, the long term efficacy of the stenting therapy is not well defined in Chinese PAD patients. To investigate the question, sixty-three PAD patients (37 males and 26 females, aged 66±7.3 years, were analysed in the study. They were featured as claudication (n=45, 71.4%, rest pain (n=18, 28.6%, or gangrene (n=8, 12.7%. In total, 161 stents were applied in aorta-iliac lesions with 2.6 stents for each patient, including 55 self-expanding stents, 98 balloon expandable stents, and 8 covered stents. The success rate of implanting Kissing-stents was 100%. Catheter-directed thrombolysis (CDT with urokinase was performed in 8 cases (12.7%. The severity of peripheral ischemia was significantly improved, as evidenced by 3.3-fold increase of ankle-brachial pressure index (ABI after the surgery (P=0.008. One, three, five, and seven years after surgery, the primary patency rate was 87.3%, 77.4%, 71.1%, and 65.0%, whereas the secondary patency rate was 95.2%, 92.5%, 89.5%, and 85.0%, respectively. No in-hospital mortality was recorded. In conclusion, Kissing-stenting technique for aorta-iliac lesions is safe and effective with lower complications. It is beneficial for aorta-iliac occlusions that are longer than 60 mm.

  18. Iterative Otsu's method for OCT improved delineation in the aorta wall

    Science.gov (United States)

    Alonso, Daniel; Real, Eusebio; Val-Bernal, José F.; Revuelta, José M.; Pontón, Alejandro; Calvo Díez, Marta; Mayorga, Marta; López-Higuera, José M.; Conde, Olga M.

    2015-07-01

    Degradation of human ascending thoracic aorta has been visualized with Optical Coherence Tomography (OCT). OCT images of the vessel wall exhibit structural degradation in the media layer of the artery, being this disorder the final trigger of the pathology. The degeneration in the vessel wall appears as low-reflectivity areas due to different optical properties of acidic polysaccharides and mucopolysaccharides in contrast with typical ordered structure of smooth muscle cells, elastin and collagen fibers. An OCT dimension indicator of wall degradation can be generated upon the spatial quantification of the extension of degraded areas in a similar way as conventional histopathology. This proposed OCT marker can offer in the future a real-time clinical perception of the vessel status to help cardiovascular surgeons in vessel repair interventions. However, the delineation of degraded areas on the B-scan image from OCT is sometimes difficult due to presence of speckle noise, variable signal to noise ratio (SNR) conditions on the measurement process, etc. Degraded areas can be delimited by basic thresholding techniques taking advantage of disorders evidences in B-scan images, but this delineation is not optimum in the aorta samples and requires complex additional processing stages. This work proposes an optimized delineation of degraded areas within the aorta wall, robust to noisy environments, based on the iterative application of Otsu's thresholding method. Results improve the delineation of wall anomalies compared with the simple application of the algorithm. Achievements could be also transferred to other clinical scenarios: carotid arteries, aorto-iliac or ilio-femoral sections, intracranial, etc.

  19. One-stage repair of tetralogy of Fallot with coarctation of the aorta.

    Science.gov (United States)

    Makhija, Zeena; Radhakrishnan, Sitaraman; Goel, Apporva; Sharma, Rajesh

    2014-09-01

    We describe the rare case of a 10-month-old girl who had coarctation of the aorta in association with tetralogy of Fallot. The surgical management and postoperative course is described. This case highlights the rare association of coarctation with tetralogy of Fallot, with a large intracardiac right-to-left shunt. Although an exception to the rule, it challenges the reduced fetal blood flow theory and the smooth muscle cell migration theory as embryological explanations for the development of coarctation. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Conventional and cine-MRI in patients with aneurysms of the abdominal aorta

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Friedmann, G.; Lemaitre, F.; Schmidt, R.; Lanfermann, H.; Erasmi, H.; Koeln Univ.

    1991-01-01

    We studied 40 patients with aneurysms of the abdominal aorta by MRI. These results were compared with those obtained by real-time sonography (n = 40), angiography (n = 32) and CT (n = 16). In 30 patients the imaging results were compared - as far as possible - with the operative findings. MRI proved more reliable, especially if compared with sonography, in evaluating renal or iliac artery involvement. Mural thrombi were detected more often (93%) by MRI than by CT (85%) or sonography (83%). Cine-MRI showed strong turbulences in 33%. Turbulences did not correlate with the size of the aneurysm. (orig.) [de

  1. Coartación de la aorta: una revisión sistemática

    Directory of Open Access Journals (Sweden)

    O Ruíz Pérez

    2015-07-01

    Full Text Available La coartación de la aorta es una patología caracterizada por el estrechamiento de la arteria aorta, con la consecuente obstrucción de su flujo; localizada con mayor frecuencia a nivel de aorta torácica descendente distal al origen de la subclavia izquierda, y en la pared posterior de la arteria. Supone aproximadamente el 5,1% (3-10% de las cardiopatías congénitas y constituye la octava malformación cardiaca por orden de frecuencia. La presentación clínica de la coartación aórtica es muy variada y depende de la severidad de la lesión y de su posible asociación con otras anomalías cardiacas. Se resalta la tipo infantil y tipo adulto, siendo la primera la que reviste mayor morbimortalidad. La ecocardiografía bidimensional y la ecocardiografía doppler son el método diagnóstico fundamental para la coartación aórtica. La angiorresonancia magnética (angio-RM contrastada, permite hacer una evaluación detallada de la aorta mediante una reconstrucción tridimensional que muestra claramente sus defectos. Por su parte, la TAC multicorte permite la visualización tridimensional del arco desde múltiples planos, pero como inconveniente tiene la emisión de radiación. El cateterismo cardiaco, constituye más que un medio diagnóstico, uno terapéutico en el cual, no sólo se demuestra la localización y extensión de la zona coartada, la presencia de lesiones asociadas y/o de circulación colateral, sino que permite la obtención de un conocimiento fiable de la severidad y repercusión hemodinámica de la misma. El tratamiento de esta patología, puede ser inicialmente médico, pero de forma definitiva por cateterismo cardíaco intervencionista y con menor frecuencia corrección quirúrgica.

  2. Surgical repair of a pseudoaneurysm of the ascending aorta after aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Almeida Rui Manuel Sequeira de

    2001-01-01

    Full Text Available We report the case of a patient with a pseudoaneurysm of the ascending aortic clinically diagnosed 5 months after surgical replacement of the aortic valve. Diagnosis was confirmed with the aid of two-dimensional echocardiography and helicoidal angiotomography. The corrective surgery, which consisted of a reinforced suture of the communication with the ascending aorta after opening and aspiration of the cavity of the pseudoaneurysm, was successfully performed through a complete sternotomy using extracorporeal circulation, femorofemoral cannulation, and moderate hypothermia, with no aortic clamping.

  3. IV DSA in the diagnosis and follow-up of dissection of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickx, P.; Luska, G.; Laas, J.; Haverich, A.

    1986-05-01

    Intravenous DSA was performed in 53 patients with suspected dissection of the thoracic aorta and in 13 patients following surgery for aortic dissection. In 36 patients, the suspected diagnosis could be excluded definitely and, in 14 cases out of 17, a dissection was correctly diagnosed. All 11 type B dissections were correctly diagnosed. Of six type A dissections, only three were adequately demonstrated by IV DSA. In type B dissections, IV DSA is reliable, but in type A dissection with massive aortic insufficiency or pericardial tamponade the findings are not reliable. In all 13 patients who had surgery for dissection, IV DSA proved suitable for showing the anastomosis and progress of the disease.

  4. Interphase death and repair of radiation injuries to thoracic aorta endothelium of mammals

    International Nuclear Information System (INIS)

    Shcherbova, E.N.; Ivanov, Yu.V.

    1978-01-01

    Using the method of plane preparations injury to the thoracic aorta endothelium of guinea-pigs, rats and rabbits exposed to various doses of γ-rays ( 60 Co) has been studied. The value of the threshold dose, tested by diminution of the endothelial cell quantity, has been found to be 250 R for guinea-pigs, 830 R, for rats and 880 R, for rabbits. It has been shown by means of the fractionated irradiation model that the interphase endothelial cells of guinea-pigs and rats can recover from sublethal radiation injuries

  5. Recirculation zone length in renal artery is affected by flow spirality and renal-to-aorta flow ratio.

    Science.gov (United States)

    Javadzadegan, Ashkan; Fulker, David; Barber, Tracie

    2017-07-01

    Haemodynamic perturbations such as flow recirculation zones play a key role in progression and development of renal artery stenosis, which typically originate at the aorta-renal bifurcation. The spiral nature of aortic blood flow, division of aortic blood flow in renal artery as well as the exercise conditions have been shown to alter the haemodynamics in both positive and negative ways. This study focuses on the combinative effects of spiral component of blood flow, renal-to-aorta flow ratio and the exercise conditions on the size and distribution of recirculation zones in renal branches using computational fluid dynamics technique. Our findings show that the recirculation length was longest when the renal-to-aorta flow ratio was smallest. Spiral flow and exercise conditions were found to be effective in reducing the recirculation length in particular in small renal-to-aorta flow ratios. These results support the hypothesis that in renal arteries with small flow ratios where a stenosis is already developed an artificially induced spiral flow within the aorta may decelerate the progression of stenosis and thereby help preserve kidney function.

  6. Customized CT angiogram planning for intraoperative transesophageal echography-guided endovascular exclusion of thoracic aorta penetrating ulcer.

    Science.gov (United States)

    Piazza, Michele; Lupia, Mario; Grego, Franco; Antonello, Michele

    2015-04-01

    The technique is demonstrated in a 78-year-old man; the preoperative CT angiogram showed a descending thoracic aorta ulcer of 5.9 cm in maximum diameter and 3.8 cm longitudinal extension. A ZTEG-2P-36-127-PF (Cook Medical) single tubular endograft was planned to be deployed. From the preoperative CT angiogram we planned to land 4.7 cm above the midline of the descending thoracic aorta ulcer and 8.0 cm below. In the operating room, under radioscopic vision the centre of the transesophageal echography probe was used as marker to identify the correspondent midline of the descending thoracic aorta ulcer and a centimeter-sized pigtail catheter in the aorta was used to calculate the desired length above and below the ulcer midline. The endograft was introduced and placed in the desired position compared to the transesophageal echography probe and the catheter; under transesophageal echography vision the graft was finally deployed. The CT angiogram at 1 month showed the correct endograft position, descending thoracic aorta ulcer exclusion with no signs of endoleak. In selected cases, this method allows planning in advance safe stent graft positioning and deployment totally assisted by transesophageal echography, with no risk of periprocedural contrast-related renal failure and reduced radiation exposure for the patient and operators. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

    International Nuclear Information System (INIS)

    Beeres, Martin; Schell, Boris; Mastragelopoulos, Aristidis; Kerl, Josef Matthias; Gruber-Rouh, Tatjana; Lee, Clara; Siebenhandl, Petra; Bodelle, Boris; Zangos, Stephan; Vogl, Thomas J.; Jacobi, Volkmar; Bauer, Ralf W.; Herrmann, Eva

    2012-01-01

    To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). (orig.)

  8. 21 CFR 870.3800 - Annuloplasty ring.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An annuloplasty ring is a rigid or flexible ring implanted around the mitral or tricuspid heart valve for reconstructive treatment of valvular insufficiency. (b) Classification. Class II (special...

  9. International Tree Ring Data Bank (ITRDB)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Tree ring data from the International Tree Ring Data Bank and World Data Center for Paleoclimatology archives. Data include raw treering measurements (most are...

  10. Planetary ring systems properties, structures, and evolution

    CERN Document Server

    Murray, Carl D

    2018-01-01

    Planetary rings are among the most intriguing structures of our solar system and have fascinated generations of astronomers. Collating emerging knowledge in the field, this volume reviews our current understanding of ring systems with reference to the rings of Saturn, Uranus, Neptune, and more. Written by leading experts, the history of ring research and the basics of ring–particle orbits is followed by a review of the known planetary ring systems. All aspects of ring system science are described in detail, including specific dynamical processes, types of structures, thermal properties and their origins, and investigations using computer simulations and laboratory experiments. The concluding chapters discuss the prospects of future missions to planetary rings, the ways in which ring science informs and is informed by the study of other astrophysical disks, and a perspective on the field's future. Researchers of all levels will benefit from this thorough and engaging presentation.

  11. Vortex rings in classical and quantum systems

    International Nuclear Information System (INIS)

    Barenghi, C F; Donnelly, R J

    2009-01-01

    The study of vortex rings has been pursued for decades and is a particularly difficult subject. However, the discovery of quantized vortex rings in superfluid helium has greatly increased interest in vortex rings with very thin cores. While rapid progress has been made in the simulation of quantized vortex rings, there has not been comparable progress in laboratory studies of vortex rings in a viscous fluid such as water. This article overviews the history and current frontiers of classical and quantum vortex rings. After introducing the classical results, this review discusses thin-cored vortex rings in superfluid helium in section 2, and recent progress in understanding vortex rings of very thin cores propagating in water in section 3. (invited paper)

  12. Mathematical simulation of bearing ring grinding process

    Science.gov (United States)

    Koltunov, I. I.; Gorbunova, T. N.; Tumanova, M. B.

    2018-03-01

    The paper suggests the method of forming a solid finite element model of the bearing ring. Implementation of the model allowed one to evaluate the influence of the inner cylindrical surface grinding scheme on the ring shape error.

  13. Dynamics of long ring Raman fiber laser

    Science.gov (United States)

    Sukhanov, Sergey V.; Melnikov, Leonid A.; Mazhirina, Yulia A.

    2016-04-01

    The numerical model for dynamics of long fiber ring Raman laser is proposed. The model is based on the transport equations and Courant-Isaacson-Rees numerical method. Different regimes of a long ring fiber Raman laser are investigated.

  14. Genetics Home Reference: ring chromosome 20 syndrome

    Science.gov (United States)

    ... drugs. Prolonged seizure episodes known as non-convulsive status epilepticus also appear to be characteristic of ring chromosome ... K, Takahashi Y. Ring chromosome 20 and nonconvulsive status epilepticus. A new epileptic syndrome. Brain. 1997 Jun;120 ( ...

  15. Infecção de prótese vascular em cirurgia da aorta torácica: revisão da experiência e relato de caso tratado por técnica não convencional Vascular prosthesis infection in thoracic aorta surgery: review of the experience and a case report illustrating treatment with an unconventional technique

    Directory of Open Access Journals (Sweden)

    Ronaldo Ducceschi Fontes

    2004-03-01

    toxemia. Pleural empyema was diagnosed, and she underwent an exploratory thoracotomy that did not confirm this diagnosis, but revealed intense effusion thickening. Four months after the exploratory thoracotomy, Klebsiella pneumoniae and Enterobacter sp were isolated in a blood culture. Magnetic resonance imaging revealed shapes compatible with perigraft infection. With this clinical and laboratory picture, graft removal was indicated as was axillo-bifemoral grafting. Surgery was successfully performed, the patient was discharged in good condition, and remains well after a 57-month follow-up without complications. The methods used for diagnosis and treatment of prosthesis infection in thoracic aorta surgery are discussed.

  16. The Hi-Ring DCN Architecture

    DEFF Research Database (Denmark)

    Galili, Michael; Kamchevska, Valerija; Ding, Yunhong

    2016-01-01

    We will review recent work on the proposed hierarchical ring-based architecture (HiRing) proposed for data center networks. We will discuss the architecture and initial demonstrations of optical switching performance and time-domain synchronization......We will review recent work on the proposed hierarchical ring-based architecture (HiRing) proposed for data center networks. We will discuss the architecture and initial demonstrations of optical switching performance and time-domain synchronization...

  17. Nonlinear analysis of ring oscillator circuits

    KAUST Repository

    Ge, Xiaoqing

    2010-06-01

    Using nonlinear systems techniques, we analyze the stability properties and synchronization conditions for ring oscillator circuits, which are essential building blocks in digital systems. By making use of its cyclic structure, we investigate local and global stability properties of an n-stage ring oscillator. We present a sufficient condition for global asymptotic stability of the origin and obtain necessity if the ring oscillator consists of identical inverter elements. We then give a synchronization condition for identical interconnected ring oscillators.

  18. On P-coherent endomorphism rings

    Indian Academy of Sciences (India)

    A ring is called right -coherent if every principal right ideal is finitely presented. Let M R be a right -module. We study the -coherence of the endomorphism ring of M R . It is shown that is a right -coherent ring if and only if every endomorphism of M R has a pseudokernel in add M R ; S is a left -coherent ring if and ...

  19. Nonlinear analysis of ring oscillator circuits

    KAUST Repository

    Ge, Xiaoqing; Arcak, Murat; Salama, Khaled N.

    2010-01-01

    Using nonlinear systems techniques, we analyze the stability properties and synchronization conditions for ring oscillator circuits, which are essential building blocks in digital systems. By making use of its cyclic structure, we investigate local and global stability properties of an n-stage ring oscillator. We present a sufficient condition for global asymptotic stability of the origin and obtain necessity if the ring oscillator consists of identical inverter elements. We then give a synchronization condition for identical interconnected ring oscillators.

  20. Beam dynamic issues in TESLA damping ring

    International Nuclear Information System (INIS)

    Shiltsev, V.

    1996-05-01

    In this paper we study general requirements on impedances of the linear collider TESLA damping ring design. Quantitative consideration is performed for 17-km long ''dog-bone'' ring. Beam dynamics in alternative options of 6.3 and 2.3-km long damping rings is briefly discussed. 5 refs., 2 tabs